Fire-Lite MPS-24AF Data Sheet
Fire-Lite MPS-24AF Data Sheet
Fire-Lite MPS-24AF Data Sheet
October 2, 2002
Sensiscan 2000
Section: Conventional
GENERAL
MEA
288-91-E
California
State Fire
Marshal
7165-0075:149
FEATURES
Initiating Device Circuits (IDC's)
Large conventional system capacity: up to 56 Style B or
Style D (Class B or A).
IDCs may be expanded in increments of 4 or 8 utilizing
IZ-4F or IZ-8F modules.
Initiating zones may be programmed to function as remote ACKNOWLEDGE, SILENCE, or RESET inputs.
Alarm and trouble reminder option.
ALARM (red) and TROUBLE (yellow) LEDs indicate status of each initiating device circuit.
Sensiscan 2000
KNOWLEDGE, SIGNAL SILENCE, and SYSTEM RESET.
NACs may be selected for California Code option (complies with Code Sections 32002 and 32003).
This document is not intended to be used for installation purposes. We try to keep our
product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without
notice. For more information, contact FireLite Alarms, One Fire-Lite Place, Northford,
Connecticut 06472.
Phone: (800) 627-3473 FAX: (877) 699-4105
Mechanicals
Labels may be easily inserted to provide identification
of all circuits.
Door may be field mounted with hinge on right or lefthand side.
The CPU-2000 includes two Notification Appliance Circuits; system alarm and trouble relays; remote station and master box transmitters. The CPU communicates with up to 7
modules (any mix of IZ, IC, CR, and TC;
NOTE: one IZ is required).
IZ-8F: Initiating Zone module, provides eight
(8) Style B (Class B) initiating device circuits
(zones). Plug-in terminal blocks are included
for ease of installation and service.
IZ-8FCS4: Same as IZ-8F with four (4) yellow supervisory Initiating Device Circuits (zones), (points 5-8). Required for Canadian Supervisory Service.
IZ-8FCS8: Same as IZ-8F with eight (8) yellow supervisory Initiating Device Circuits (zones), (points 1-8). Required for Canadian Supervisory Service.
IZE-AF: Initiating Zone Expander, converts
IZ-8F to eight (8) Style D (Class A) initiating
device circuits (maximum of one per IZ-8F).
Plug-in terminal blocks are included for ease
of installation and service.
Page 2 of 4 DF-50439
AFM-16ATXCS4: Same as AFM-16ATX with four (4) yellow supervisory indications (points 13-16). Required for
Canadian Supervisory Service.
MPM-2: Main Power Meter kit for MPS-24AF only. Includes battery voltage and charging current meters, mounting hardware, and cable.
AFM-32AXCS8: Same as AFM-32AX with eight (8) yellow supervisory indications (points 25-32). Required for
Canadian Supervisory Service.
AFM
ANNUNCIATORS
The AFM Series Annunciators communicate along a twowire, twisted-pair EIA-485 circuit, which can be run up to
6,000 feet from the control panel. Designed to provide remote annunciation of Sensiscan 2000 I/O circuits, each
AFM annunciator includes: an internal alarm/trouble piezo,
SILENCE switch, LAMP TEST switch, POWER-ON LED,
and SYSTEM TROUBLE LED. Each AFM includes slidein zone labels for custom messages that may be printed or
typed. Unique features of each AFM Series annunciator
are listed below.
MP-1F:
Panel.
Module Dress
CHS-4F: Expansion
Chassis,
includes CHS-4 Chassis,
MP-1F Module Dress
Panel, and the expander
ribbon cable for second
cabinet row.
Required for CAB-B3F systems.
CONSTRUCTION
Each module consists of one or two printed circuit cards that
mount to the CHS-4 chassis with captive screws.
Windows in the hinged dress panel allow for viewing of the
status LEDs. Slide-in pockets allow the insertion of descriptive labels for the circuits (label windows are 0.88" [2.235 cm]
high by 0.98" [2.489 cm] wide).
The MPS Main Power Supply mounts in the lower left corner
of the enclosure. Space is provided next to the power supply
for up to 25 Amp-Hours of gelled electrolyte batteries.
The Central Processor Unit (CPU-2000) module monitors and
controls up to seven initiating, notification and control modules, mounted in chassis assemblies. AVPS-24F power supplies may be substituted in module positions, or mounted below a single (non-expanded) module.
A key-locked hinged door enclosure is offered in two sizes.
The door is provided with a window that allows for viewing of
the modules with the door closed. The door assembly is separable from the backbox to allow easy installation.
ELECTRICAL SPECIFICATIONS
Primary input power, 120 volts, 50/60 HZ, 2.4 amperes
maximum.
240 volts, 50/60 Hz primary input power options are available
(order MPS-24AFE, MPS-24BFE, AVPS-24FE).
Ground fault detection.
Low primary AC input power supervision with brown
out indication.
Supervised standby batteries (order separately):
PS-695: Battery, 6 V, 9.5 AH, Gel Cell (order 4). Use
only with MPS-24AF.
PS-1270: Battery, 12 V, 7.0 AH, Gel Cell (order 2).
Use only with MPS-24BF.
PS-12120: Battery, 12 V, 12 AH, Gel Cell (order 2).
Use with either MPS-24AF or MPS-24BF.
PS-12170: Battery, 12 V, 17 AH, Gel Cell (order 2).
Use with either MPS-24AF or MPS-24BF.
PS-12250: Battery, 12 V, 25 AH, Gel Cell (order 2).
Use only with MPS-24AF.
PS-12600: Battery, 12 V, 60 AH, Gel Cell (order 2).
Use only with MPS-24AF. Requires BB-55F battery
box for housing.
INSTRUCTION MANUAL
BB-55F: UL listed
Battery Box.
Required to externally
mount
two (2) PS-12600,
60 AH batteries.
Page 4 of 4 DF-50439
An installation, operation, and programming manual is provided with each Sensiscan 2000.