Engine Datasheet F3-6L912 1500 Min

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Engine Datasheet F3-6L912 1500 min-1

Engine
Type
Speed
Net frequency
Power standard
Power level
Exhaust emission standard
General
Aspiration
No of cylinders
Configuration
Injection system
Displacement
Bore
Stroke
Compression ratio
Mean effective pressure
Piston speed
Rotation (looking at flywheel)
No of teeth on flywheel ring gear
Governor performance
Speed droop (static) mech. gov.
Speed droop (static) electr. gov. (EMR/GAC)
Governing standards
to ISO 8528 Parts 1 and 5
Moment of inertia
Engine without flywheel
Flywheel (standard genset spec.)
Max. step load acceptance, 1st step
Sound power at full load, incl. cooling system 5
Sound press. (1m average, full load), incl. cool. syst.
Weight
Engine dry, w/o cooling system
Engine with cooling system
Lubrication system
Oil specification
Oil consumption (as % of fuel consumption)
Oil capacity (sump)
Min. oil pressure (warning)
Min. oil pressure (shut down)
Max. permissible oil temperature (oil pan)
Output
Gross output
Fan reduction
Net flywheel1
Electrical output 2
Fuel System
Fuel consumption
25% load3
50% load3
75% load3
100% load3
25% load
50% load
75% load
100% load
Max. suction head of fuel feed pump

[min-1]
[Hz]

F3L912

F4L912

F6L912

1500
50
LTP
---

1500
50
LTP
---

1500
50
LTP
---

[l]
[mm]
[mm]

natural
4
in-line
direct

100
120
20

100
120
20

100
120
20

129

6
counter clock wise
129

129

56
0

56
0

56
0

G2

G2

G2

[kg m]
[kg m]
[%]
[dB(A)]
[dB(A)]

0,16
1,02
95
103
90

0,181
1,02
95
104
91

0,279
1,02
95
106,5
93

[kg]
[kg]

-351

-402

-541

[l]
[bar]
[bar]
[C]

0,5
9
1,5
1,5
130

see operation manual


0,5
11
1,5
1,5
130

0,5
13,5
1,5
1,5
130

[kW]
[kW]
[kW]
[kVA]

28.5
0,5
28,0
29,8

38.5
0,5
38,0
41,8

57.0
1,0
56,0
62,3

2,8
3,9
5,4
7,4

3,8
5,3
7,3
10,0

5,5
7,8
10,9
15,0

1,5

1,5

1,5

[bar]
[m/s]

[%]
[%]

[l/h]
[l/h]
[l/h]
[l/h]
[g/kWh]
[g/kWh]
[g/kWh]
[g/kWh]
[m]

Engine Datasheet F3-6L912 1500 min-1


Engine
Type
Cooling System
General engine cooling data
Max. perm. coolant outlet temperature
Max. perm. flow resistance (cool. syst. and piping)
Max. temperature of coolant (warning)
Max. temperature of coolant (shutdown)
Temperature at which thermostat starts to open
Temperature at which thermostat is fully open
Delivery of coolant pump
Min. pressure before coolant pump
Temperature at CAC outlet at standard conditions
DEUTZ cooling system
Coolant capacity (engine)
Coolant capacity (incl. cooling unit)
Air to boil (max. permissible cool. air temp. at fan)
Fan power consumption4
Cooling air flow
Air pressure loss
Heat Balance
Heat dissipation (engine radiator) 6
Heat dissipation (CAC)6
Heat dissipation (convection)
Inlet / Exhaust Data
Max. intake depression (Switch setting)
Combustion air volume
Max. exhaust back pressure
Max. exhaust gas temperature
Exhaust gas flow (at above temp)
Exhaust flange / pipe diameter
Electrical System
Voltage
Starter
Alternator output
Batteries (minimum capacity, cold start limit -5C)

F3L912

F4L912

F6L912

[C]
[bar]
[C]
[C]
[C]
[C]
[m3/h]
[bar]
[C]

----------

----------

----------

[l]
[l]
[C]
[kW]
[m3/h]

---0,50
1565
10

---0,50
1810
10

---1,00
2610
10

[kW]
[kW]
[kW]

--23

--29

--45

[mbar]
[m3/h]
[mbar]
[C]
[m3/h]
[mm]

20
108
30
510
273
66

20
144
30
510
362
66

20
216
30
530
558
66

12
3,1
55
1 x 110

12
3,1
55
1 x 110

12
3,1
55
1 x 110

[V]
[kW]
[A]
[Ah]

Ratings in accordance with ISO 3046.

Ratings in accordance with ISO 8528, based on alternator efficiency of 85% to 89%.

At calorific value 42700 kJ/kg + 5 %, density 0.835 kg/dm3, temperature 280 K.

Technical data and max. permissible torque for fan drive see data sheet.

Sound power values measured in accordance with ISO 6798.

The heat quantities are valid for the dimensioning of the cooling system. They are given for the engine with the highest fuel consumption.

For further information see ELTAB / Pocket book.


For further application guidance see DEUTZ Installation Manual.
All data are provided for informational purposes only and are subject to amendment.