1400GQKA D3246c PDF
1400GQKA D3246c PDF
1400GQKA D3246c PDF
Model:
Frequency:
Fuel Type:
Emissions Performance NOx:
LT Water Inlet Temperature:
HT Water Outlet Temp:
1400GQKA
60 Hz
Natural Gas MI 75 +
0.7 g/hp-hr
50oC (122oF)
90oC (194oF)
MSP-1007
PTS-158
0500-4321
See Note
90% of Rated
Load
3514 (12)
37.2%
35.9%
75% of Rated
Load
50% of Rated
Load
Engine
Engine Manufacturer
Engine Model
Configuration
Displacement, L (cu.in)
Aspiration
Gross Engine Power Output, kWm (hp)
BMEP, bar (psi)
Bore, mm (in)
Stroke, mm (in)
Rated Speed, rpm
Piston Speed, m/s (ft/min)
Compression Ratio
Lube Oil Capacity, L (qt)
Overspeed Limit, rpm
Regenerative Power, kW
Full Load Lubricating oil consumption, g/kWe-hr (g/hp-hr)
Cummins
QSK60G
V16
60.3 (3683)
Turbocharged (2)
1451 (1945)
16.1 (233)
159 (6.26)
190 (7.48)
1800
11.4 (2244)
11.4:1
380 (401)
2070
N/A
0.15 (0.11)
Fuel
0.24 (3.5)
75
Starting System(s)
Electric starter voltage, volts
Minimum battery capacity @ 40 deg.C (104 deg.F), AH
Air Starter Pressure, barg (psig)
Air Starter Flow Nm3/s (scfm)
24
450
NA
NA
2,10
10
5
5
5
5
13
13
5
4
4
4
4
6
6,14
6,14
HT Cooling Circuit
HT Circuit Engine Coolant Volume, l (gal)
HT Coolant Flow @ Max Ext Restriction, m3/h (gal/min)
Max HT Engine Coolant Inlet Temp, oC (oF) Reference
HT Coolant Outlet Temp, oC (oF)
Max Pressure Drop in External HT Circuit, bar (psig)
HT Circuit Maximum Pressure, bar (psig)
Minimum Static Head, bar (psig)
LT Cooling Circuit
LT Circuit Engine Coolant Volume, l (gal)
LT Coolant Flow @ Max Ext Restriction, m3/h (gal/min)
Maximum LT Engine Coolant Inlet Temp, oC (oF)
LT Coolant Outlet Temp, oC (oF) Reference Only
Max Pressure Drop in External LT Circuit, bar (psig)
LT Circuit Maximum Pressure, bar (psig)
Minimum Static Head, bar (psig)
50% of Rated
Load
1451 (1945)
1400
214 (0.73)
493 (1.68)
126 (0.43)
958 (3.27)
81 (0.27)
209 (0.71)
1032 (3.52)
1306 (1750)
1260
204 (0.70)
464 (1.58)
115 (0.39)
878 (3.00)
75 (0.26)
201 (0.69)
963 (3.29)
1094 (1466)
1050
195 (0.66)
392 (1.34)
102 (0.35)
727 (2.48)
64 (0.22)
180 (0.62)
840 (2.86)
738 (990)
700
159 (0.54)
321 (1.09)
82 (0.28)
528 (1.80)
47 (0.16)
161 (0.55)
643 (2.19)
2.39 (18913)
1.85 (4124)
18 (9.8)
2.15 (17029)
1.66 (3713)
18 (9.8)
1.83 (14457)
1.41 (3152)
18 (9.8)
1.26 (9965)
0.97 (2173)
18 (9.8)
2.23
4.77
483
37.3
1.89
4.10
493
37.3
1.30
2.94
522
37.3
2.47
5.24
475.1
37.3
(19578)
(11089)
(887)
(20.0)
NA NA
(17634)
(10095)
(902)
(20.0)
NA NA
(14970)
(8682)
(919)
(20.0)
NA NA
(10332)
(6216)
(971)
(20.0)
NA NA
8
8
181
83
80
90
1.50
3.5
0.5
(48)
(365)
(176)
(194)
(22)
(51)
(7)
181
83
80
90
1.50
3.5
0.5
(48)
(365)
(176)
(194)
(22)
(51)
(7)
181
83
80
90
1.50
3.5
0.5
(48)
(365)
(176)
(194)
(22)
(51)
(7)
181
83
80
90
1.50
3.5
0.5
(48)
(365)
(176)
(194)
(22)
(51)
(7)
9
9
34
29
50
54.0
1.00
3.5
0.5
(9)
(125)
(122)
(129)
(15)
(51)
(7)
34
29
50
54.0
1.00
3.5
0.5
(9)
(125)
(122)
(129)
(15)
(51)
(7)
34
29
50
54.0
1.00
3.5
0.5
(9)
(125)
(122)
(129)
(15)
(51)
(7)
34
29
50
54.0
1.00
3.5
0.5
(9)
(125)
(122)
(129)
(15)
(51)
(7)
Emissions
NOx Emissions wet, ppm
108
108
106
103
5
13
13
13
13
13
13
307 (0.70)
1068
1192 (2.74)
437
766 (1.74)
9.5
< 0.03
304 (0.70)
1113
1231 (2.85)
431
744 (1.71)
9.3
< 0.03
301 (0.70)
1124
1253 (2.94)
405
709 (1.65)
9.4
< 0.03
279 (0.70)
1210
1289 (3.27)
388
663 (1.67)
8.8
< 0.03
Genset De-rating
Altitude and Temperature Derate Multiplication Factor
Barometer
Altitude
In Hg
mbar
Feet
20.7
21.4
22.1
22.8
23.5
24.3
25.0
25.8
26.6
27.4
28.3
29.1
29.5
30.0
701
723
747
771
795
820
846
872
899
926
954
983
995
1012
9843
9022
8202
7382
6562
5741
4921
4101
3281
2461
1640
820
492
0
Table A *
Meters
3000
2750
2500
2250
2000
1750
1500
1250
1000
750
500
250
150
0
C
F
0.67
0.70
0.74
0.77
0.80
0.83
0.86
0.89
0.92
0.96
0.99
1.00
1.00
1.00
25
77
0.66
0.65
0.63
0.61
0.69
0.68
0.66
0.64
0.72
0.71
0.70
0.67
0.75
0.74
0.73
0.70
0.79
0.77
0.76
0.73
0.82
0.80
0.79
0.76
0.85
0.84
0.82
0.79
0.88
0.87
0.85
0.83
0.91
0.90
0.89
0.86
0.94
0.93
0.92
0.89
0.97
0.96
0.95
0.92
1.00
0.99
0.98
0.95
1.00
1.00
0.99
0.96
1.00
1.00
1.00
0.98
30
35
40
45
86
95
104
113
Air Filter Inlet Temperature
0.58
0.61
0.64
0.67
0.70
0.74
0.77
0.80
0.83
0.86
0.89
0.92
0.94
0.96
50
122
0.55
0.58
0.61
0.64
0.68
0.71
0.74
0.77
0.80
0.83
0.86
0.90
0.91
0.93
55
131
0.52
0.55
0.58
0.62
0.65
0.68
0.71
0.74
0.77
0.81
0.84
0.87
0.88
0.90
60
140
* Based on SAE standard ambient pressure vs. altitude. Assumes LT return temperature is 10C above air filter inlet.
Barometer
Altitude
In Hg
mbar
Feet
Meters
20.7
21.4
22.1
701
723
747
771
795
820
846
872
899
926
954
983
995
1012
9843
9022
8202
7382
6562
5741
4921
4101
3281
2461
1640
820
492
0
3000
2750
2500
2250
2000
1750
1500
1250
1000
750
500
250
150
0
22.8
23.5
24.3
25.0
25.8
26.6
27.4
28.3
29.1
29.5
30.0
C
F
Table B *
Derate Multiplier Off Grid (Island or Load Share)
0.67
0.70
0.73
0.76
0.80
0.83
0.86
0.89
0.92
0.95
0.98
1.00
1.00
1.00
0.66
0.69
0.72
0.75
0.78
0.81
0.85
0.88
0.91
0.94
0.97
1.00
1.00
1.00
20
68
25
77
0.64
0.67
0.71
0.74
0.77
0.80
0.83
0.86
0.90
0.93
0.96
0.99
1.00
1.00
0.63
0.66
0.69
0.72
0.76
0.79
0.82
0.85
0.88
0.91
0.94
0.98
0.99
1.00
0.62
0.65
0.68
0.71
0.74
0.77
0.81
0.84
0.87
0.90
0.93
0.96
0.98
0.99
0.58
0.62
0.65
0.68
0.71
0.74
0.77
0.80
0.84
0.87
0.90
0.93
0.94
0.96
0.55
0.58
0.61
0.65
0.68
0.71
0.74
0.77
0.80
0.84
0.87
0.90
0.91
0.93
0.52
0.55
0.58
0.61
0.65
0.68
0.71
0.74
0.77
0.80
0.83
0.87
0.88
0.90
0.52
0.55
0.58
0.61
0.64
0.68
0.71
0.74
0.77
0.80
0.83
0.85
0.87
30
35
40
45
50
86
95
104
113
122
Air Filter Inlet Temperature
55
131
60
140
* Based on SAE standard ambient pressure vs. altitude. Assumes LT return temperature is 10C above air filter inlet.
Altitude
In Hg
mbar
Feet
Meters
20.7
21.4
22.1
22.8
23.5
24.3
25.0
25.8
26.6
27.4
28.3
29.1
701
723
747
771
795
820
846
872
899
926
954
983
995
1012
9843
9022
8202
7382
6562
5741
4921
4101
3281
2461
1640
820
492
0
3000
2750
2500
2250
2000
1750
1500
1250
1000
750
500
250
150
0
29.5
30.0
C
F
Table C
Multiplier for HT & LT Heat Rejection vs Alt & Temp.
0.00
1.11
1.10
1.09
1.08
1.07
1.06
1.05
1.04
1.02
1.01
1.00
0.99
0.99
0.00
1.13
1.12
1.10
1.09
1.08
1.07
1.06
1.05
1.04
1.03
1.02
1.00
1.00
20
68
25
77
0.00
1.14
1.13
1.12
1.11
1.09
1.08
1.07
1.06
1.05
1.04
1.03
1.02
1.01
0.00
1.15
1.14
1.13
1.12
1.11
1.10
1.09
1.07
1.06
1.05
1.04
1.03
1.03
0.00
1.17
1.15
1.14
1.13
1.12
1.11
1.10
1.09
1.08
1.07
1.05
1.04
1.04
0.00
1.18
1.17
1.16
1.14
1.13
1.12
1.11
1.10
1.09
1.08
1.07
1.06
1.05
0.00
1.19
1.18
1.17
1.16
1.15
1.14
1.12
1.11
1.10
1.09
1.08
1.07
1.06
0.00
1.20
1.19
1.18
1.17
1.16
1.15
1.14
1.13
1.12
1.10
1.09
1.08
1.08
0.00
1.22
1.21
1.20
1.18
1.17
1.16
1.15
1.14
1.13
1.12
1.11
1.10
1.09
30
35
40
45
50
86
95
104
113
122
Air Filter Inlet Temperature
55
131
60
140
Alternator Data
Voltage Range
380-480
416-480
600
380-416
440-480
480
600
440-480
4160
4160
12470-13800
Connection
Configuration
Wye, 3 Phase
Wye, 3 Phase
Wye, 3 Phase
Wye, 3 Phase
Wye, 3 Phase
Wye, 3 Phase
Wye, 3 Phase
Wye, 3 Phase
Wye, 3 Phase
Wye, 3 Phase
Wye, 3 Phase
Continuous Rating
Definition
Temp Rise
Degrees C
80
80
80
105
105
105
105
125
80
105
80
11
Duty
Cycle
C
C
C
C
C
C
C
C
C
C
C
Alternator
Data Sheet
334
333
333
332
332
331
331
331
324
323
521
Feature
Code
B830-2
B587-2
D589-2
B831-2
B832-2
B583-2
B582-2
B650-2
B590-2
B834-2
B591-2
Notes
1) Weights and set dimesions represent a generator set with its standard features only. See outline drawing for other configurations.
2) At ISO3046 reference conditions, altitude 1013 mbar (30in Hg), air inlet temperature 25oC (77oF)
3) Nominal performance +/- 2 1/2%
4) According to ISO 3046/I with fuel consumption tolerance of +5% -0% or efficiency tolerance of +0% -5%.
5) Production variation/tolerance 5%.
6) With air intake at 25oC (77F). Tolerance 5F.
7) Tested using pipeline natural gas with LHV of 33.44mJ/Nm3 (980BTU/ft3)
8) Outlet temperature controlled by thermostat. Inlet temperature for reference only.
9) Inlet temperature controlled by thermostat, outlet temperature for reference only.
10) With engine driven coolant pump.
11) Standby (S), Prime (P), Continuous ( C)
12) Maximum rated starting kVA that results in minimum of 90% of rated sustained voltage during starting.
13) Tolerance +/- 15%
14) Exhaust system back pressure is a rated load and will decrease at lower loads.
Cummins and PowerCommand are registered trademarks of Cummins Inc. AmpSentry is a trademark of Cummins Inc.
Important: Back feed to a utility system can cause electrocution and/or property damage. Do not connect to any building's electrical system
except through an approved device or after building main switch is open.