Boq Mep Final
Boq Mep Final
Boq Mep Final
Item
Description
Unit
Qty
Unit Price
Total Amount
Division 15 - Mechanical
AIR CONDITIONING SERVICES
Unless otherwise stated, the work shall pertain to the secondarydesign, supply,
installation, testing commissioning, warranty &maintenance of the following
works. Where quantities have not beenincluded , the contractor shall indicate
the quantities as per his own take off from the Tender document.
15.1
Air Handling Units complete with all connections, valves, filters, accessories
and fittings, as per Schedule in Particular specifications.
Nos.
15.2
Fresh air handling units completed with all connections, valves, filters, heat
exchangers, heat pipes, electrical heaters, accessories and fittings as per
Particular Specification.
Nos.
15.3
15.4
Control system for the Air Conditioning system, including all control valves,
sensors motorised dampers, motorised valves, DDC controls, MCC's etc.
complete as detailed in "Schedule of Controls"of the Particular Specifications.
Item
Fan coil units completed with all connections, valves, secondary drain apns,
etc. as per "Schedule of Fan Coil Units"of the Particular Specifications.
Nos.
185
15.5
Fan Coil units (dual coil) for ICUs and recovery rooms with standby DX
condensing units including refrigerant piping and all accessories as specified
in particular specifications.
Nos.
15.6
Close circuit unit and MDF rooms with standby DX coil and condensing unit
including refrigerant piping and accessories as specified in particular
specifications.
Nos.
15.7
Fire dampers with access panels in ducts at all duct entry & exits from plant
rooms as well as fire wells/zones and motorized fire dampers and motorized
smoke dampers as shown on drawing.
Item
15.8
Item
15.9
No.
15.9.1
FANS
Basement ventilation and exhaust fans complete with required controls and
accessories as specified.
15.9.2
No.
Extract air fans with motorized volume control damper as shown in drawings
and relevant controls as specified.
No.
15.9.3
No.
15.9.4
No.
15.9.5
Pressurization fans with chilled water coil and VFD with associated controls
as specified.
No.
15.9.6
No.
15.1
Condensing units with refrigerant piping and all necessary controls and
accessories for operation theatre Air Handling Units.
No.
15.11
Nos.
15.12
Nos.
15.13
3 duty/1 standby CHW primary pumps complete with all connections, valves,
test points, gauges, header and fittings and controls.
Item
15.14
Item
15.15
Item
LS
15.16
Item
LS
NAGA
Item
Description
Unit
Qty
Unit Price
Total Amount
Item
LS
15.18
Smoke extract system complete with smoke extract fans, smoke curtain and
powered ventilator interfaces with building FA system as specified.
Item
LS
15.19
Chilled water piping with insulation and all accessories including isolating
valves on supply & balancing valve on return, all as specified, with hangers,
support, fittings etc 300mm dia pipe.
15.19.1
15.19.2
15.19.3
15.19.4
15.19.5
15.19.6
M
M
M
LS
LS
LS
M
M
M
LS
LS
LS
15.19.7
15.19.8
M
M
LS
LS
15.19.9
M
M
LS
LS
LS
M
Item
LS
LS
M2
5100
Item
Item
Item
Item
Item
LS
8
15.20
15.20.1
15.20.2
15.20.3
15.20.4
15.20.5
15.21
Sound attenuators for supply, extract & return air systems ductwork as
required to maintain specified NC level within all conditioned spaces.
Door louvres as required & where shown on drawings
Noise and vibration control for the following equipment including inertia
basis, vibration isolators, flexible connectors etc for
*
*
*
*
Item
Item
150
Item
LS
15.22
Condensate drain piping for AHUs, FCUs and other A/C equipment as
required
Item
LS
15.23
Item
LS
15.24
3rd party air balancing, chilled water balancing, testing & commissioning of
all HVAC plant, equipment & systems
Item
15.25
LS
LS
Item
15.26
Item
15.27
Spare set of filters (one complete set off all filters to be handed over after
commissioning). The spare set to be used to exchange installed temporary
throw away filters during installation.
Item
15.28
Item
LS
15.29
Item
LS
LS
LS
NAGA
Item
Description
Unit
Qty
Item
LS
Unit Price
Total Amount
15.30
15.31
The Tenderer is to attach this bill of quantities any additional items with
quantities, enumerated or itemised and rates which are not previously
included to complete the build-up of the lump sum tender price for this
section of the works. Should the Tenderer fail to insert any items here, it will
be deemed that his lump sum price for the tender includes all items either
shown on the drawings and described in the specification or deemed necessary
by the Tenderer to develop the drawings and specification to represent the
entire cost of the works and no subsequent claim for any additional item will
be entertained.
NAGA
Item
Description
Unit
Qty
Unit Price
Total Amount
NAGA
Item
Description
Unit
Qty
Unit Price
Total Amount
15.32
15.32.1
15.33
Unless otherwise stated, the work shall pertain to the secondary design,
supply, installation, testing, commissioning, warranty & maintenance of the
following works. Where quantities have not been included, the contractor
shall indicate the quantities as per his own take-offs from the Tender
document.
Incoming water supply connection to provisions made available in plant room,
as shown on drawing W-01.
Item
Gas fired central water heaters as per "Schedule of Water Heaters of the
Particular Specification complete with interconnecting valves, fitting and
accessories.
Nos.
L/S
15.34
Item
15.35
Hose bibs with integral vacuum breaker & hose end adaptor
No.
15.36
15.36.1
Domestic cold water pipework complete with fittings, valves supports and
accessories as per Specifications and drawings.
Item
15.36.2
Domestic cold water & hot water PEX piping within toilets & kitchens
complete with valves, distribution boxes, headers/manifold etc.
Item
15.37
Item
15.38
15.39
Nos.
15.4
Nos.
15.41
CWS Booster pumps (1 duty/1 standby assist/1 jockey) complete with all
valves, test points, headers, pressure gauges, pipe work, fittings, VCDs, VFD
and accessories including pressure vessel as specified.
Nos.
15.42
Hot water recirculation pump set (1 run/1 standby) with valves and
accessories and controls
15.44
item
15.45
Heat exchanger for 28C water storage for 28C water supply ass per
specifications
No.
15.46
No.
NAGA
Item
Description
Unit
Qty
15.47
Panel type water tanks 3 x 1.5 x 2.5mH for normal water storage including all
connections and accessories as per specifications.
Nos.
15.48
Panel type insulated water tank 3 x 1.5 x 2.5mH for 28C water storage
including all connections and accessories as per specifications
Nos.
Unit Price
Total Amount
15.5
Additional Items
15.51
Item
The Tenderer is to attach with this bill of quantities any quantities items with
quantities, enumerated or itemised and rates which are not previously
included to completethe build-up of the lump-sum tender price for this section
of the works. Should the Tenderer fail to insert any items here, it will be
deemed that his lump sum price for the tender includes all items either shown
on the drawings and described in the specification to represent the entire cost
of the works and no subsequent claim for any additional item will be
entertained.
NAGA
Item
Description
Unit
Qty
Unit Price
Total Amount
NAGA
Item
Description
Unit
Qty
Unit Price
Total Amount
15.52
Unless otherwise stated, the work shall pertain to the secondary design,
supply, installation, testing, commissioning, warranty & maintenance of the
following works. Where quantities have not been included, the contractor
shall indicate the quantities as per his own take-offs from the Tender
document:
15.53
No.
15.53.1
RWO
No.
15.53.2
FD-K in kitchen
No.
37
15.53.3
FD-K 1
No.
11
15.53.4
No.
14
15.53.5
No.
15.53.6
FD in toilets
No.
20
15.53.7
No.
37
15.53.8
FT
No.
128
15.53.9
No.
No.
No.
2
2
15.53.12
Manhole frames & cover for all manholes,external valve pits, gulley traps, etc.
(Civil work only by others)
Item
15.53.13
Condensate drain pipes complete with all fittings 19mm closed cell, insulation
with protective covering, accessories and supports
Item
Item
Item
No.
No.
No.
NAGA
Item
Description
Unit
Qty
15.54
Drainage piping, fitting and accessories, all as per drawings & specifications
in vertical & horizontal runs
Item
15.55
Acoustic lagging for all horizontal runs of DEWAge lines above occupied
spaces as specified.
Item
15.56
Sanitary drainage connections, soil waste & vest including final connections
to fixtures and stacks & horizontal runs at low and high level were shown for
all saanitary fixtures:
Item
15.57
MH vents pipe
Item
15.58
Item
Unit Price
Total Amount
L/S
Pressure brake MH
Item
15.60
Item
15.61
Sand trap
Item
15.62
Miscellaneous
DM approvals & coordination for same to obtain final permission to connect
15.63
Close-out documentation
Item
Item
DRAINAGE SERVICES
15.54
50MM WP
523
50MM VP
843
50MM KWP
20
80mm WP
320
80mm KWP
65
100mm WP
137
100mm SP
130
100mm VP
200
100mm RWP
41
150mm WP
455
150mm SP
318
150mm KWP
63
150mm RWP
105
200mm WP
114
200mm SP
117
NAGA
Item
Description
Unit
Qty
150mm VP
52
FCO150mmO
No.
80mmO
110
Unit
10.755
Unit Price
Total Amount
15.64
The Tenderer is to attach with this bill of quantities any additional items with
quantities, enumerated or itemised and rates which are not previously
included to complete the build-up of the lump-sum tender price for this
section of the works. Should the Tenderer fail to insert any items here, it will
be deemed that his lump sum price for the tender includes all items either
shown on the drawings and described in the specification to represent the
entire cost of the works and no subsequent claim for any additional item will
be entertained.
Division 15 - Mechanical
DRAINAGE SERVICES
Total of Drainage Services
Page 1
Page 2
Page 3
Page 4
Page 5
Page 6
NAGA
Item
Description
Unit
Qty
Item
L/S
Item
20
Unit Price
Total Amount
15.65
Unless otherwise stated the work shall pertain to the secondary design,
obtaining approvals from Civil Defence, supply, installation, testing,
commissioning, warranty and maintenance of the following works: All
components to be UL listed or FM approved.
15.66
Sprinkler pipe as per NFPA 13 with threaded (up to 50mm) and victaulic end
fittings (65mm & longer)
15.67
15.68
Fire Hose reel cabinets with 30m hose 25 o, wet riser landing valve 65o &
protable extinguishers.
Item
15.69
Item
15.70
Protable extinguishers in plant rooms and other areas as shown. CO2 & dry
powder type as on Drawing. Generator rooms, cylinder rooms, etc.
Item
15.71
Item
Item
1 set
15.72
15.72.1
15.72.2
15.72.3
15.73
With all associated valves, fuel oil tank etc and pump control panel.
15.74
Item
15.75
CO2 system with controls as specified and as shown on drawing for fuel tank
room
Item
15.76
Fuel tank for fuel storage with fill line, discharge line, pumps with valves and
controls for filling of roof installed genset day tank.
Item
Additional Items
NAGA
Item
15.77
Description
Unit
Qty
Item
Unit
275
Unit
245
Unit
83
Unit
20
Unit
13
Unit
The Tenderer is to attach with this bill of quantities any additional items with
quantities, enumerated or itemised and rates which are not previously
included to complete the build-up of the lump-sum tender price for this
section of the works. Should the Tenderer fail to insert any items here, it will
be deemed that his lump sum price for the tender includes all items either
shown on the drawings and described in the specification or deemed necessary
by the Tenderer to develop the drawings and specification to represent the
entire cost of the works and no subsequent claim for any additional item will
be entertained.
Unit Price
Total Amount
15.70
15.71
NAGA
Item
Description
Unit
Qty
Unit Price
Total Amount
NAGA
Item
Description
Unit
Qty
Unit Price
Total Amount
15.78
LPG System
Supply, install, test & commission of LPG system comprising of:
15.79
Nos.
15.8
Nos.
15.81
Item
15.82
Item
15.83
Item
NAGA
Item
Description
Unit
Qty
Unit Price
Total Amount
NAGA
Item
Description
Unit
Qty
Unit Price
Total Amount
16.1
16.1.1
16.2
16.2.1
16.2.2
16.2.3
16.2.4
16.2.5
16.2.6
16.2.7
16.2.8
16.2.9
16.2.10
16.2.11
16.2.12
16.2.13
16.2.14
16.2.15
16.2.16
16.2.17
16.2.18
16.2.20
16.2.21
Unless otherwise stated, the work shall pertain to the secondary design,
supply, installation, testing commissioning, warranty & maintenance of the
following works. Where quantities have not been included, the contractor
shall indicate the quantities as per the Tender document.
Coordination with DEWA for the supply of power to LV panel installed under
this contract. Cable already existing from MDB to SMDB in Electrical room
as shown on the drawing.
Item
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
Item
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
NAGA
Item
16.3
16.3.1
16.3.2
16.3.3
16.4
Description
Capacitor Banks
Capacitor Bank-1
Capacitor Bank-2
Capacitor Bank-3
Unit
Qty
No.
No.
No.
1
1
1
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
Item
No.
6
3
4
1
10
2
40
10
3
4
No.
No.
No.
No.
No.
No.
No.
No.
No.
94
25
No.
49
No.
Unit Price
Total Amount
16.4.1
16.4.2
16.4.3.
16.4.4
16.4.5
16.4.6
MCC-RF
EMCC - RF
MCC-Chiller
MCC-Pump
MCC B1
Uninterruptible power supply unit with battery
16.6
20A DP outlet with spur outlet and with neon indicated and marker for hand
dryer.
Connection point/outlet
70
46
No.
Section 01200 - BOQ
Page 37 of 37
NAGA
Item
16.6.13
16.6.14
16.6.15
16.6.17
16.6.18
16.6.19
16.6.20
16.6.21
16.6.22
16.6.23
16.6.24
16.7
Description
Voice/data RJ45 outlets
Light switches complete with all accessories. IP56 for all plant rooms
Isolator (W/P) outlet with complete wiring and installation for equipment as
per drawing
Unit
Qty
Unit Price
Total Amount
No.
No.
No.
Floor box with no. 13A double socket + 2 RJ 45 socket and blank plate
compete installation and wiring.
Industrial TP and SP socket for equipment as per drawing
Lighting point
Switch point
Cable trays as required
Trunking as required
PVC ducts as required
No.
No.
No.
Item
Item
Item
Light switches complete with all accessories, brush stainless steel for
occupied areas
Item
35
No.
35
16.80
16.8.1
16.8.2
16.8.3
Cat 6 Cable, patch panels & all and conduits in concealed and exposed
installations:
Telephone outlet RJ45
Data outlets RJ45
Main incoming connections form the existing Etisalat JRC manholes
Item
No.
No.
Item
22
20
No.
131
No.
No.
No.
No.
160
28
13
39
No.
Fire alarm control panel complete with necessary accessories, brackets and
fittings as per drawing and specifications.
Smoke detector
Smoke detector + buzzer
Heat detector
Optical detector
Sounder/sounder W/P
Manual call point
Fire alarm repeater panel
Allow for interface fire alarm system with fire fighting
Allow for interface fire alarm system with smoke panel
Allow for interface fire alarm system with lift
Allow for interface FA system with automatic doors
No.
No.
No.
16.10
No.
16.11
No.
163
16.12
No.
140
No.
262
No.
No.
36
297
16.9.12
16.12.1
16.12.2
16.12.3
16.13
Normal lighting fixtures with convertible kit to feed from central battery
system on emergency condition.
Analog abbressable break glass
Ceiling speaker (surface/recessed/wall mounted type)
2x9 W surface mounted circular light fittings on staircases with central battery
backup
NAGA
Item
16.14
16.14.1
16.14.2
16.14.3
16.14.4
16.14.5
16.14.5.1
16.14.5.2
16.14.6
16.14.7
16.14.8
16.14.9
16.14.10
16.14.11
16.14.12
16.14.13
16.14.14
Description
All fittings IP21 except in toilets to be IP65, external to be weather proofed
and for riser storage & preparation and within paint booth areas to be sealed
type explosion proof fittings.
4 x 18W fluorescent light with louver
4 x 18W fluorescent tube fitting HF control gear weather proof
2 x 36W fluorescent tube fitting with diffused as B type
1 x 36W fluorescent tube fitting as BB type
Down lighters (1 x 18W)
Down lighters (2 x 9W)
2 x 9 surface mounted M.T.D. circular fluorescent light with PL lamp.
Mirror lights type K
2 x 36W fluorescent explosion proof type
1 x 50W wall mounted light fittings IP65
External lights, as per drawings
Main Distribution frame (By others). Etisalat charges directly by client.
Patch panels
Telephone manholes with covers
Twin voice/data RJ45 outlets
Diesel engine generator of rating with accessories and controls and load test.
Unit
Qty
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
33
No.
Unit Price
Total Amount
222
3
12
45
56
9
39
1
1
1
Sundries
Earthing and Bonding system of all metal structure, all panels, mechanical
plant, etc.
Lighting protection system
Other work associated with external cabling
Allow for associated ducting for electrical and LV services.
Item
Item
Item
Item
Additional Items
16.16
The tenderer is to attach with this bill of quantities any additional items with
quantities, enumerated or itemized and rates which are not previously
included to complete the build-up of the lump-sum tender price for this
section of the works. Should the Tenderer fail to insert any items here, it will
be deemed that this lump sum price for the tender includes all items either
shown on the drawings and described in the specification or deemed necessary
by the Tenderer to develop the drawings and specification to represent the
entire cost of the works and no subsequent claim for any additional item will
be entertained.
Item
NAGA
Item
Description
Unit
Qty
Unit Price
Total Amount
NAGA
Item
Description
Unit
Qty
Unit Price
Total Amount
Item
Item
Item
Item
Warranty of works
Item
Item
NAGA
Item
Description
Unit
Qty
Unit Price
Total Amount
NAGA
Item
Description
Unit
Qty
Unit Price
Total Amount