1492 br016 - en P PDF
1492 br016 - en P PDF
1492 br016 - en P PDF
Bulletin 1492 In-Panel Wiring Systems for 1762 MicroLogix 1200 Controllers with 40 Embedded I/O
Bulletin 1492 In-Panel In Panel Wiring Systems for Flex I/O using Flex d-shell base modules
Bulletin 1492 In-Panel Wiring Systems for 1764 MicroLogix 1500 Base I/O Units
Bulletin 1492 In-Panel Wiring Systems for CompactLogix and MicroLogix 1500 Expansion I/O (1769 Compact I/O)
Bulletin 1492 In-Panel Wiring Systems for SLC 500 (1746 I/O)
NOTE: In addition to the above Allen-Bradley PLCs, a select group of Bulletin 1492 wiring system modules interface to PowerFlex 700S and 700H drive control I/O.
The assembler begins the arduous task of measuring, and cutting each control wire.
1:08
14:58
18:04
The assembler using the traditional method has measured and cut about 10 of the 18 wires needed for the same job. And there are numerous steps remaining.
24:37
34:34
37:00
Finally half of the process is complete and PLC Module is wired and snapped into place.
Assembler begins tagging each wire before connecting it to the terminal blocks.
46:30
The assembler removes the Bulletin 1492 Interface Module (IFM) from its box and applies the supplied preprinted labels to mark the terminals.
Assembler removes pre-wired 1492 cable from the box and connects the PLC end of the cable to the PLC.
1:04
1:08
Then routes the cable through the wire duct and snaps the other end of cable to the 1492 IFM Module.
Time is Money!
You can achieve up to 75% savings on your control wiring time and reduce wiring errors when using a Bulletin 1492 Wiring System compared with wiring to traditional terminal blocks. To see a video comparing the two wiring methods go to www.ab.com/ industrialcontrols/products/terminal_blocks_ and_wiring/wiring/digital_interface.html and click on 1492 PLC Wiring System Timesaver Video under Related Links.
1492
1492
1492
1492
1492
Type
1492 Digital Feedthrough Interface Module 8/16/32 Point Input and Output Feedthrough Interface Modules 20 or 40 Pin Latch Header Supports 8/16/32 point AC and DC inputs and output digital modules (Sink & Source) Supports 1756, 1769, 1746, 1794 and 1771 Modular I/O Also supports all MicroLogix 1764 base I/O, 1762-L40XX base I/O, 700H and 700S PowerFlex Control I/O Standard Extra Terminal Sensor Fixed and Removable (Removable as screw or push-in style) 0265V AC/DC 12 A per module 2 A per Circuit IP20 20 and 40 Latch Header 210 mm (max) to 60 mm (min) x 83 mm x 5075 mm
1492 Digital LED Interface Module 8/16/32 Point Input and Output LED Interface Modules LEDs support field wire indication 20 or 40 Pin Latch Header Supports 16/32 point AC and DC inputs and output digital modules (Sink & Source) Supports 1756, 1769, 1746, 1794 and 1771 I/O Platform
1492 Digital Fused Interface Module 8/16/32 Point Input and Output Fused Interface Modules Fuse holders support circuit protection (optional fuse blown indication) 20 or 40 Pin Latch Header Supports 16/32 point AC and DC inputs and output digital modules (Sink & Source) Supports 1756, 1769, 1746, 1794 and 1771 I/O Platform Standard Extra Terminal Fixed and Removable (Removable as screw or push-in style) 1030V AC/DC 85132V AC 12 A per module 2 A per Circuit IP20 20 and 40 Latch Header 210 mm (max) to 110 mm (min) x 83 mm x 5075 mm
1492 Digital Relay Output and Expansion Module 8/16/32 Point Output Relay and Expansion Interface Modules Masters Modules Relay and relay with fused output common Relays rated at 12 Amps per pair Expansion Modules relays, fused and feedthrough 20 or 40 Pin Latch Header Supports 16/32 point AC and DC digital output modules Supports 1756, 1769, 1746, 1794 and 1771 I/O Platform Standard Fixed and Removable (Removable as screw or push-in style)
1492 Analog Interface Module Feedthrough 4/8/16 Channel Input and Output Feedthrough Interface Modules 15 or 25 Pin D-Shell to I/O with shield Supports inputs and output analog modules Supports 1756, 1769, 1746, 1794 and 1771 I/O Platforms, 700H and 700S PowerFlex Control I/O
Description
Features
Standard Extra Terminal Sensor Fixed and Removable (Removable as screw or push-in style) 1030V AC/DC 85132V AC 12 A per module 2 A per Circuit IP20 20 and 40 Latch Header 210 mm (max) to 110 mm (min) x 83 mm x 5075 mm
Rated Voltage Maximum Current Degree of Protection I/O Connection Pin Count Connector/Body Dimensions Cable O.D.
2028V DC 85132V AC 10 A per Relay Output IP20 20 and 40 280 mm (max) to 160 mm (min) x 83 mm x 65 mm
1030V DC 100132V AC 12 A per module 2 A per Circuit IP20 D-Shell 15 and 25 114.5 mm x 83 mm x 5065 mm
Field Terminal Wire Range (Rated Cross Reference) Indicator Circuit Current (Nominal) Certifications
#22#12 AWG (0.24 mm2) cULus: Hazardous Locations Class I DIV 2, CE, Factory Mutual
#22#12 AWG (0.24 mm2) 2.02.6 mA cULus: Hazardous Locations Class I DIV 2, CE, Factory Mutual
#22#12 AWG (0.24 mm2) 1.22.5 mA cULus: Hazardous Locations Class I DIV 2, CE, Factory Mutual
#22#12 AWG (0.24 mm2) cULus: Hazardous Locations Class I DIV 2, CE, Factory Mutual
www.ab.com/components
1492
1492
1492
1492
1492
1492 Analog Interface Module Fuse 4/8/16 Channel Input Fused Interface Modules 15 or 25 Pin D-Shell to I/O with shied Supports inputs analog modules Supports 1756, 1769, 1746, 1794 and 1771 I/O Platforms, 700H and 700S PowerFlex Control I/O
1492 Analog Interface Module (Thermocouple) 6 Channel Thermocouple Input Module for 1756 25 Pin D-Shell to I/O with shied Supports thermocouple input analog module Supports 1756 I/O Platform
1492 CABLE & 1492-CAB 1492 to PLC Pre-Wired Digital I/O Cables 20 or 40 pin Standard length cables 0.5, 1.0, 2.5, 5.0 mm 20 or 40 pin build to order length cables Supports 1756, 1769, 1746, 1794, and 1771 I/O Platforms #22 AWG Wire
1492-ACABLE & 1492ACAB 1492 to PLC Pre-Wired Digital I/O Cables 15 and 25 pin Standard length cables with shield 0.5, 1.0, 2.5, 5.0 mm 15 and 25 pin build to order length cables with shield Supports 1756, 1769, 1746, 1794 and 1771 I/O Platforms #22 AWG Wire
IFM Ready
I/O Ready
1492 IFM Ready Cables for Digital I/O 20 or 40 pin IFM Standard Length cables with flying leads 1.0,2.5,5.0 mm 20 or 40 pin build to order length cables with flying leads Supports 1756, 1769, 1746, 1794, 1771 and other or non-Allen-Bradley I/O Platforms #18 and #22 AWG Wire
1492 I/O Ready Cables for Digital I/O I/O ready 20 or 40 connection standard length cables with flying leads 1.0, 2.5, 5.0 mm I/O Ready 20 or 40 connection build to order length cables Supports 1756, 1769, 1746, 1794 and 1771 I/O Platforms #18 and #22 AWG Wire
Extra Terminal
Extra Terminal
1030V DC 10132V AC 12 A per module 2 A per Circuit IP20 D-Shell 15 and 25 114.5 mm x 83 mm x 43 mm (out) & 38 mm (in)
6.78 mm (0.267) 7.44 mm (0.293) 8.43 mm (0.332) 10.2 mm (0.40) 11.5 mm (0.45)
9.0 mm (0.36)
#22#12 AWG (0.24 mm2) cULus: Hazardous Locations Class I DIV 2, CE, Factory Mutual
#22#12 AWG (0.24 mm2) cULus: Hazardous Locations Class I DIV 2, CE, Factory Mutual
www.ab.com/components
Selection Overview
Please refer to the Bulletin 1492 Wiring Systems Technical Data and the Allen-Bradley Industrial Controls catalog for detailed in formation and catalog number explanations. Programmable Logic Controllers are: MicroLogix, PLC-5, SLC500 Implement specific functions such as: I/O control logic timing communication report generation data file manipulation arithmetic counting
Types of Controllers:
Programmable Automation Controllers: CompactLogix, ControlLogix and FlexLogix Merge PC-based and PLC architecture Provide multidiscipline automation (i.e., process, discrete, motion, drive and batch) within a single hardware and software platform Provide scalability and application portability within an open, modular architecture number) and the column (I/O module). The Letter Code represents the suffix of the pre-wired cable.
Modules: IFM Interface Module RTB Removable Terminal Block RIFM RTB Style IFM XIM Relay Master/Expander RXIM RTB Style XIM AIFM Analog IFM RAIFM RTB Style Analog IFM
Copyright 2009 Rockwell Automation, Inc. All Rights Reserved. Printed in USA.