VDSHJ402 Sonometer 1100 DS 1111 Press
VDSHJ402 Sonometer 1100 DS 1111 Press
VDSHJ402 Sonometer 1100 DS 1111 Press
Description/Application
The SONOMETER1100 is an ultrasonic static compact energy meter especially designed for heating, cooling or combined heating/cooling application in local and district energy systems. The SONOMETER1100 as a compact energy meter consists of the following components: - Ultrasonic flow sensor; - Calculator with integral hardware and software for measuring flow rate, temperature and energy consumption; - Pair of temperature sensors.
Features - 1st. approval in Europe for ultrasonic energy meter with dynamic range of qi/qp 1 : 250 in class 2 (qp 1.5 / 2.5 / 6 / 10 / 15 / 25 / 40 / 60 m/h) - Complete dynamic range: 1 : 1500 - Lithium battery, 230 V AC or 24 V AC mains unit - Battery lifetime 11 years (16 years optional) - Unique free- beam principle - Improved service-friendly energy meter design - Housings with thread and flange (PN 16 / 25) - Can be configured for heating, cooling or combined heating/cooling application - Temperature range: 5 - 130 / 150 C - Overload temperature up to 150 C (qp= 0.6 - 2.5 m3/h) - Swirl-free flow around reflector - Lower pressure loss - Robust stainless steel reflector - Insensitive to dirt - Available in nominal sizes - Measuring accuracy meets the requirements of EN 1434 ( MID) class 2 and 3 - No calming sections necessary in the inlet and/or outlet (standard installation)
qp 0.6 / 1.0 / 1.5 / 2.5 / 3.5 / 6 / 10 / 15 / 25 / 40 / 60 m/h
Special Features - Power save mode - NOWA test capability - Remote reading via M-Bus, L-Bus, RS 232, RS 485, Radio or optical interface - Integrated Radio (868 or 434 Hz), Real Data or Open Metering Standard (OMS) - Individual remote reading (Automatic Meter Reading) with add on modules Plug&Play - 2 communication ports (e.g. M-Bus + M-Bus) - Improved radio performance - Individual tariff functions - History memory for 24 months - Extensive diagnostic displays - IZAR@SET parameterization software on Windows basis guarantees optimum adaptation to the users specific needs
DEN-SMT/PL
Data Sheet
Ordering: The ordering code no. consists of both dummy code and ordering code. Dummy code: 087G6011 Ordering code: AAA BB - C D E F G H P AAA - application energy meter for heating energy meter for cooling 1,2 energy meter for heating/cooling 1
1
L M - NN O 0 1 4 00 AT BA BG CN DK CZ DE GB HR IE IT KZ LV MD PL RO RU CS SK SI TR UA 0 1 2 3 4 O - verification without approval mark, no test reports compliant according to national regulations PTB K 7.2 for cooling compliant to MID. With letter of conformity 1
1
includes potting and special temperature sensors for cooling or heating/cooling application 2 meter without type approval
BB - flow sensor qp 0.6 m/h / 110 mm thread / DN 15 / GB qp 0.6 m/h / 130 mm thread / DN 20 / G1B qp 0.6 m/h / 190 mm thread / DN 20 / G1B qp 1.0 m/h / 110 mm thread / DN 15 / GB qp 1.0 m/h / 130 mm thread / DN 20 / G1B qp 1.0 m/h / 190 mm thread / DN 20 / G1B qp 1.5 m/h / 110 mm thread / DN 15 / GB qp 1.5 m/h / 130 mm thread / DN 20 / G1B qp 1.5 m/h / 190 mm thread / DN 20 / G1B qp 2.5 m/h / 130 mm thread / DN 20 / G1B qp 2.5 m/h / 190 mm thread / DN 20 / G1B qp 3.5 m/h / 260 mm thread / DN 25 / G11/4B qp 6 m/h / 260 mm thread / DN 25 / G11/4B qp 10 m/h / 300 mm thread / DN 40 / G2B qp 0.6 m/h / 190 mm flange DN 201 qp 1.0 m/h / 190 mm flange DN 201 qp 1.5 m/h / 190 mm flange DN 201 qp 2.5 m/h / 190 mm flange DN 201 qp 3.5 m/h / 260 mm flange DN 251 qp 3.5 m/h / 260 mm flange DN 321 qp 6 m/h / 260 mm flange DN 251 qp 6 m/h / 260 mm flange DN 321 qp 10 m/h / 300 mm flange DN 401 qp 15 m/h / 270 mm flange DN 501 qp 25 m/h / 300 mm flange DN 651 qp 40 m/h / 300 mm flange DN 801 qp 60 m/h / 360 mm flange DN 1001
1
1A 1B 1C 1D 1E 1F 1G 1H 1I 1J 1K 1L 1M 1N 2A 2B 2C 2D 2E 2F 2G 2H 2I 2J 2K 2L 2M
only PN 25 possible!
NN - country code Neutral code with docs in English (standard) Austria Bosnia Bulgaria China Denmark Czech Republic Germany United Kingdom Croatia Ireland Italy Kazakhstan Latvia Moldova Poland Romania Russia Serbia Slovak Republic Slovenia Turkey Ukraine
M - connections (sets) without screwing set R x G B screwing set R x G 1 B screwing set R 1 x G 11/4 B screwing set R 1 x G 2 B
C D
flange versions must be PN 25
D - cable length between calculator and flow sensor 1.5 m (standard) 3m 5m1 0.2 m 2
1
A B C D
not possible for qp 3.5 m/h and qp to 6 m/h versions 2 max. 90C possible. Only for qp 0.6 - 2.5 versions
L - accessories / pocket 0 without for 5.2 mm temperature sensors (pair1) F brass-pockets, 35 mm, MID 2 G brass-pockets, 52 mm, MID H brass-pockets, 85 mm, MID I brass-pockets, 120 mm, MID 3 stainless steel-pockets, 85 mm, MID 4 stainless steel-pockets, 120 mm, MID 5 stainless steel-pockets, 155 mm, MID 6 stainless steel-pockets, 210 mm, MID
E - installation low temperature high temperature F - power supply battery 3.6 V DC (A-cell) (standard) battery 3.6 V DC (D-cell) 1 mains unit 230 V AC mains unit 24 V AC
1
L H 1 2 3 4
Standard for integrated radio
1 versions with one sensor pocket on request 2 max temperature: 105C temperature sensor pockets are packaged in an extra box
for 6.0 mm temperature sensors (pair) V brass-pockets, 40 mm MID W brass-pockets, 85 mm MID X brass-pockets, 120 mm MID Y stainless steel-pockets, 85 mm MID Z stainless steel-pockets, 120 mm MID 1 stainless steel-pockets, 155 mm MID 2 stainless steel-pockets, 210 mm MID
GH - interface modules modules slot 1 no module in slot 1 Analogue output module (4-20mA)1 Combined module (2 pulse inputs / 1 pulse output) Pulse input module (2 inputs) M-Bus module L-Bus module (use for external radio) RS232 module RS485 module modules slot 2 no module in slot 2 Pulse output module2 Combined module (2 pulse inputs / 1 pulse output)2 Pulse input module (2 inputs)2 M-Bus module2 L-Bus module (use for external radio)2 RS232 module 2 RS485 module 2 P - version of communication without integrated radio (standard) Radio 868 MHz Real Data Radio 434 MHz Real Data Radio 868 MHz Open Metering Standard Radio 434 MHz Open Metering Standard
0 A B C D E F G 0 A B C D E F G
Accessories (1 piece) 3 R ball valve DN 15 - for direct sensor S ball valve DN 20 - for direct sensor T ball valve DN 25 - 1 for direct sensor U adapter for mounting direct sensor R M 10x1
3 not possible for 6.0 mm sensors ball valves packaged in an extra box
1 2 3 4
K - temperature sensor mounting Direct sensor mounting (qp 0.6 - qp 2.5) 1 (standard) Direct sensor mounting (qp 3.5 - qp 15) 1 Pocket sensor mounting (2 free sensors) (qp 0.6 - qp 2.5)2 Pocket sensor mounting (2 free sensors) (qp 3.5 - qp 60) (standard)
2
1 one temperature sensor mounted in the body 2 free sensors, temperature sensor drill in the body closed
N O P Q T U V W 0 1 2 3 4
J - temperature sensors (pair) Pt 500 / 5.2 mm / 2 m cable, MID and 22.77/08.04 (standard) Pt 500 / 5.2 mm / 3 m cable, MID and 22.77/08.04 Pt 500 / 5.2 mm / 5 m cable, MID and 22.77/08.04 Pt 500 / 5.2 mm / 10 m cable, MID and 22.77/08.04 1 Pt 500 / 6.0 mm / 2 m cable, MID 2 Pt 500 / 6.0 mm / 3 m cable, MID 2 Pt 500 / 6.0 mm / 5 m cable, MID 2 Pt 500 / 6.0 mm / 10 m cable, MID 1, 2
2
A B C D E F G H I J K L M
I - energy units kWh (without digit after comma) MWh (with 1 digit after comma) MWh (with 2 digit after comma) MWh (with 3 digit after comma) GJ (with 1 digit after comma) GJ (with 2 digit after comma) GJ (with 3 digit after comma) Gcal (with 1 digit after comma) 1 Gcal (with 2 digit after comma) 1 Gcal (with 3 digit after comma) 1 MBtu (with 1 digit after comma) 1 MBtu (with 2 digit after comma) 1 MBtu (with 3 digit after comma) 1
1
DEN-SMT/PL
Data Sheet
Ordering continued
Function
Supply voltage
pair
1
1 Set 12 pcs 12 pcs 12 pcs
Ball valves
Coupling thread
Sensor thread
Set
Code No.
M 10 x 1
32 pcs
087G6076
Tailpieces
Threaded
Set 1 pc 1 pc 1 pc 1 pc
Software
The IZAR@SET parameterization software on windows basis is a convenient tool for handling the energy meter. The IZAR@SET software is available on web site www.hydrometer.de.
It is used for: - commissioning - reading out measured values - printing out energy meter logs - energy meter configuration - application analysis - print the meter protocol
DEN-SMT/PL
Data Sheet
Technical data
Nominal Flow rate ranges Maximum Minimum Starting Nominal Diameter Connection Tailpiece Operating Maximum pressure
Flow sensor heating Temp. range
0.6 1.2 6 1 20 G 1B R 16 / 25 FL 25 15 G B R
2.5 5 10 4 20 G 1B R 16 / 25 FL 25 25 G 11/4B R1 16 / 25
3.5 7 35 7 32 FL 25 25 G 11/4B R1 16 / 25
6 12 24 7 32 FL 25
15 30 601) / 150 40 50 FL 25
25 50 1001) / 150 50 65 FL 25
40 80 160 80 80 FL 25
Medium Pressure loss At qp p mbar mm 110 85 130 190 110 36 / 75 130 190 130 100 190
circulation water (pH-value: 7 - 10) 44 260 128 260 95 300 80 270 75 300 80 300 75 360
Overall length
Pt 500 with 2-wire leads Pt 500 peak < 2; rms < 0.012 Mains unit supply: 2 A-cell battery: 16; D-cell battery: 4 177
Max. max temperature K difference Input Min. min temperature K difference Starting temperature K difference Absolute temperature measuring C range Supply voltage Operating voltage Ambient class Protection class Basic features Storage and Transport temperature Type Measuring process Display Units Display indication Total values Values displayed
1) 2)
0.125
1...180
UN
3.6 V DC (Lithium-battery) / 230 V AC / 24 V AC EN 1434 class E1 + M1 calculator: IP 54 flow sensor: IP 54 (heating) / IP 68 (cooling) -40...+50 Static energy meter to EN 1434 (MID) Ultrasonic volume measurement LCD, 8-digit MWh - kWh - GJ - Gcal - MBtu - gal - GMP - C - F - m - m/h 99 999 999 - 9999 999.9 - 999 999.99 - 99 999.999 Power - energy - flow rate - temperature - volume
Only for horizontal installation Only in rising or falling pipes or tilted installation
DEN-SMT/PL
Data Sheet
Design and function
DEN-SMT/PL
Data Sheet
Design and function, continued
The data saved in the log memory can be used for the following analyses: - Reading the calculator on a certain day. Example: If the day for reading is 01.10, the calculator reading is displayed for the period from 01.10 of the previous year to 30.09 of the current year. - Comparison of the last consumption period with the preceding period
Max. Actual Values Memories The calculator creates maximum values for power, flow rate and temperatures based on consumption time, which are stored in the EEPROM. The integration intervals are adjustable to 6, 15, 30 or 60 minutes, 24 hours (and 1024 seconds). Default setting is 60 minutes. Tariff Function The calculator offers four optional tariff memories for monitoring plant load states for limit tariffs. Extensive tariff conditions make it possible to adapt the energy meter individually to the required customer-specific applications. The following limit types are possible: (This example applies to the display with 3 decimal places)
Type T TR TF P Q Z LIMIT LIMIT resolution 1 ... 255 C 1 C 1 ... 255 C 1 C 1 ... 255 kW 1 kW 100 ... 25 500 l/h 100 l/h 15 minutes
Display Control The readings are displayed on the calculator by a 8-digit LCD with units and symbols. Loop Structure The SONOMETER1100 display has six loops. Some display windows consist of two (to maximum seven) displays that are shown alternately at 4-second intervals. Some pictures in loops or a complete loop can be deactivated separately.
For quick visual guidance, the loops in the display are numbered from 1 to 6. The main loop with the current data, e.g. for energy, volume and flow rate is programmed as default setting.
According to above table the energy or the time (in hours) how long the tariff condition is fulfilled will be stored in the tariff memories.
DEN-SMT/PL
Data Sheet
Overview of Loops
DEN-SMT/PL
Data Sheet
Informative Displays (Standard)
Loop Sequence 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.9 1.10 Sequence 2.1 2.2 2.3 2 Accounting date loop 2.4 2.5 2.6 2.7 Loop 2.8 Sequence 3.1 3.2 3.3 3.4 3.5 3.6 3.7 3.8 3.9 3.10 Loop 4 Pulse input loop [off] = not active Sequence 4.1 4.2
1 Main loop
Loop
Window 1 Accumulated energy Volume Flow Power Forward / - return temperature Difference temperature Operating days Error status Display test Window 1 Accounting date 1 date Next accounting date 1 date Previous accounting date 1 date ,Accd 1' Accounting date 2 date Next accounting date 2 date Previous accounting date 2 date ,Accd 2' Window 1 Current date ,SEC_Adr' ,Pri_Adr 1' ,Pri_Adr 2' Installation position ,Port 1' ,Port 2' Status integrated radio No. of error hours ,F01-001' (software version) Window 1 ,In1' ,In2'
Window 2
Window 3
Window 4
Window 2 Accounting date 1 energy Next accounting date 1 energy Previous accounting date 1 energy Date of next accounting date 1 Accounting date 2 energy Next accounting date 2 energy Previous accounting date 2 energy Date of next accounting date 2 Window 2 Secondary address Primary address 1 Primary address 2 No. of the mounted module at port 1 No. of the mounted module at port 2 (Sequence will be shown only in meters with integrated radio) Checksum Window 2 Accumulated values pulse input 1 Accumulated values pulse input 2
Window 3 [off] Accounting date 1 volume Next accounting date 1 volume Previous accounting date 1 volume Accounting date 2 volume Next accounting date 2 volume Previous accounting date 2 volume Window 3
Window 4 ,Accd 1A' ,Accd 1L' ,Accd 1' ,Accd 2A' ,Accd 2L' ,Accd 2' Window 4
3 Info loop
Window 4
DEN-SMT/PL
Data Sheet
Loop 5 Tariff loop Loop Sequence
The tariff loop is switched off as a standard at the heat meter or meter for cooling. Sequence 6.1 6.2 6.3 ... 6.24 Window 1 ,LOG ,LOG ,LOG ,LOG Window 2 date last month date month - 1 date month - 2 ... date month - 23 energy volume Window 3 [off] Window 4 [off] Window 5 energy energy energy Window 6 volume volume volume Window 7
Simple operation A push-button mounted on the front of the calculator is used to switch to the various displays. The button can be pressed for a short or long time. A short press of the button ( < 3 seconds) switches to the next display within a loop and a long press ( > 3 seconds) switches to the next display loop. The Energy window (sequence 1.1) in the main loop is the basic display.
The calculator switches automatically to power save mode if the button is not pressed for approx. 4 minutes and returns to the basic display when the button is pressed again. The loop settings can be programmed to suit the customers individual requirements using the IZAR@SET software.
DEN-SMT/PL
Data Sheet
Mounting
DEN-SMT/PL
10
Data Sheet
Dimensions
L2
R
AGV AGZ
L L1
L1 L1
Nominal size L [mm] L1 [mm] L2 [mm] B [mm] R [mm] H [mm] h [mm] AGZ AGV D [mm] d [mm] F [mm] K [mm] Weight [kg] 82 14.5 GB DN 15 R 0.76 110 190
qp = 1.0 / 1.5 m/h 110 190 130 230 150 100 54 190 290 190 190
qp = 3.5 m/h 260 380 260 260 260 260 150 100 54
qp = 10 m/h qp = 15 m/h qp = 25 m/h qp = 40 m/h qp = 60 m/h 300 440 300 300 270 270 300 300 150 100 54 300 300 360 360
84 18 G1B DN 20 R 0.85
84 18 G1B DN 20 R -
84 47.5 FL DN 20 105 14 95 75
82 14.5 GB DN 15 R 0.76
84 18 G1B DN 20 R -
84 18 G1B DN 20 R -
84 47.5 FL DN 20 105 14 95 75
84 18
84 18
84 47.5
88.5 23
94 33 G2B
DN
K
d
114 92.5 FL DN 80 200 19 185 160 10.9 119 108 FL DN 100 235 22 216 190 16.4 G1B G1B DN DN 20 20 R R FL G11/4B DN DN 20 25 105 14 95 75 R1 1.5 R1 3.1 0.96 2.75 0.85 0.96 2.75 0.85 0.96 2.75
11
DEN-SMT/PL
Data Sheet
Dimensions, continued Temperature sensors
Type Pt 500
L (mm) 45
45
50
Sensor pockets
Type Sensor dimension Brass (mm) 5.2 6.0 Stainless steel 6.0
47
60
93
128
47
92
128
98
133
168
223
35
52
85
120
40
85
120
85
120
155
210
12
VD.SH.J4.02