RXE
RXE
RXE
Switch Sitnal
RXD
Number of Signals 1 8
- Remote Sensor System which inductively supply power and transmit signals through two air gaps. - Possible to connect with Exclusive proximity switchRXD.
Signals
Page 48 48 49 50 51 52
Type code
Page 55 55 55 55
Type code
: N NPNP PNPD DC2 wire(Transmitter only _ _ at the end means cable length(m). Examples are showed below.
RXT-1202-PU-01
cable length(m) 01=1m 02=2m 03=3m
Transmitter
RXE-1202N-PU-02
N=NPN P=PNP cable length(m) 02=2m 03=3m 05=5m
Output sensor
The Transmitter and the Output sensor should be same size on same table.
h16
Switch Signal
M 12
Transmitter Output sensor
Size
0...2mm
Operating distance
4 1 LED
30 35.5
38 61.5 (2000)
A009
Wiring Transmitter
Type code Detector RXD
C012/P.109
Output sensor
Type code NPN
Mechanical SW Drive voltage Drive current Input signal Operating distance Center offset Drive current OperatingTemperature Protection class Cable Material Housing
Active surface
RXT-1202-PU-01 RST-1202-PU-01
----1 0...2mm0...1.6mm 1.5mm --0...+50 IP67 PUR / 5 2x0.34mm2 Nickel plated brass Nylon12 : operating distance at flush-mounted
PNP Operational voltage Current consumption Output signal Load capacity Frequency of operation LED OperatingTemperature Protection class Cable Material Housing
Active surface
RXE-1202N-PU-02 RXE-1202P-PU-02
24V DC 10incl. ripple 25mA 1 max.100mA 25Hz Signal output indication 0...+50 IP67 PUR / 5 3x0.34mm2 Nickel plated brass Nylon12
Note
Note
Applicable switch
- This remote sensor is only for the followings.refer to P.55 RXD-0801-PU-_ _ RXD-1202-PU-_ _ RXD-1805-PU-_ _ RXD-3010-PU-_ _ - The siize of RXD can be different from the size of the Active surface. - For mechanical limit switch, no-LED indicator and small load type is appreciated.
Mounting
In order to avoid influence of surrounding metal, or to avoid mutual influence between parallel-mounted sensors, keep the minimum free zone as described below.
Mutual interference
C
B
4 3
2
X
1
8 6 4 2 0 2 4 6 X 8
A(mm) 126
B(mm)
C(mm)
120 10020
: flush-mounted
h48
RXD
Transmitter
Switch Signal
detected signal
0...5mm
Operating distance
Remote Sensor
Products table
(2000)
10
10
33.5 59
DC3 wire Detector type DC3 wire Terminal type Wiring C012/P.109 DC2 wire Detector type DC2 wire Terminal type DC2 wire/ Exclusive switch Exclusive switch DC2 wire/ Two air gaps Exclusive proximity swithch Terminal Box Accessories Thermocouple K type Thermocouple J type Resistance thermometer sensor
Transmitter
Type code
Output sensor
Type code
Detector RXD RXT-1805-PU-01 ----1 0...5mm0...4mm 2.5mm --0...+50 IP67 PUR / 5 2x0.34mm2 Nickel plated brass Nylon12
NPN PNP
RXE-1805N-PU-02 RXE-1805P-PU-02
24V DC 10incl. ripple 25mA 1 max.100mA 25Hz Signal output indication 0...+50 IP67 PUR / 5 3x0.34mm2 Nickel plated brass Nylon12
Drive voltage Drive current Input signal Operating distance Center offset Drive current OperatingTemperature Protection class Cable Material Housing
Active surface
Operational voltage Current consumption Output signal Load capacity Frequency of operation LED OperatingTemperature Protection class Cable Material Housing
Active surface
Note
Note
Applicable switch
- This remote sensor is only for the followings.(refer to P.55 RXD-0801-PU-_ _ RXD-1202-PU-_ _ RXD-1805-PU-_ _ RXD-3010-PU-_ _ - The siize of RXD can be different from the size of the Active surface. - For mechanical limit switch, no-LED indicator and small load type is appreciated.
Mounting
In order to avoid influence of surrounding metal, or to avoid mutual influence between parallel-mounted sensors, keep the minimum free zone as described below.
B
Center offset Operating distance (mm)
5
4 3 2 X 10 8 6 4 2 0 2 4 6 8 10 1
A(mm) 189
B(mm)
C(mm)
180 11035
: flush-mounted
h49
Switch Signal
M 18
Transmitter Output sensor
Size
1...5mm
Operating distance
4 1 LED
35 (1000) 61
10
10
63 77.5 94 (2000)
Wiring Transmitter
Type code
C027/P.109
Output sensor
Type code NPN
RXD/mechanical
RXT8-1805-PU-01
----8 1...5mm 2.5mm --0...+50 IP67 PUR / 7.9 9x0.2mm2 Nickel plated brass Nylon12
PNP Operational voltage Current consumption Output signal Load capacity Frequency of operation LED OperatingTemperature Protection class Cable Material Housing
Active surface
RXE8-1800N-PU-02 RXE8-1800P-PU-02
24V DC 10incl. ripple 150mA 8+1inzone max.50mA/ output type 100Hz INZONE 0...+50 IP67 PUR / 7.7 2x0.5mm2+9x0.2mm2 Nickel plated brass Nylon12
Drive voltage Drive current Input signal Operating distance Center offset Drive current OperatingTemperature Protection class Cable Material Housing
Active surface
Note
Note
Applicable switch
- This remote sensor is only for the followings.refer to P.55 RXD-0801-PU-_ _ RXD-1202-PU-_ _ RXD-1805-PU-_ _ RXD-3010-PU-_ _ - The siize of RXD can be different from the size of the Active surface. - For mechanical limit switch, no-LED indicator and small load type is appreciated.
Mounting
In order to avoid influence of surrounding metal, or to avoid mutual influence between parallel-mounted sensors, keep the minimum free zone as described below.
Mutual interference
C
B
7 6 5 4 3 2 1 6 5 4 3 21 0 1 2 3 4 5 6 X
X
A(mm) 18
B(mm) 18
C(mm) 110
h50
Transmitter RXD
Switch Signal
detected signal
1...10mm
Operating distance
LED
(41.5)
Remote Sensor
Products table
M30x1.5 36 35 13.5 13.5 66 83.5 95 (2000)
(1000)
64
DC3 wire Detector type DC3 wire Terminal type C027/P.109 DC2 wire Detector type DC2 wire Terminal type DC2 wire/ Exclusive switch Exclusive switch DC2 wire/ Two air gaps Exclusive proximity swithch Terminal Box Accessories Thermocouple K type Thermocouple J type Resistance thermometer sensor
A004
Wiring Transmitter
Type code
Output sensor
Type code
RXD/mechanical
RXT8-3010-PU-01
----8 1...10mm 3mm --0...+50 IP67 PUR / 7.9 9x0.2mm2 Nickel plated brass Nylon12
NPN PNP
RXE8-3000N-PU-02 RXE8-3000P-PU-02
24V DC 10incl. ripple 150mA 8+1inzone max.50mA/ output type 100Hz INZONE 0...+50 IP67 PUR / 7.7 2x0.5mm2+9x0.2mm2 Nickel plated brass Nylon12
Drive voltage Drive current Input signal Operating distance Center offset Drive current OperatingTemperature Protection class Cable Material Housing
Active surface
Operational voltage Current consumption Output signal Load capacity Frequency of operation LED OperatingTemperature Protection class Cable Material Housing
Active surface
Note
Note
Applicable switch
- This remote sensor is only for the followings.refer to P.55 RXD-0801-PU-_ _ RXD-1202-PU-_ _ RXD-1805-PU-_ _ RXD-3010-PU-_ _ - The siize of RXD can be different from the size of the Active surface. - For mechanical limit switch, no-LED indicator and small load type is appreciated.
Mounting
In order to avoid influence of surrounding metal, or to avoid mutual influence between parallel-mounted sensors, keep the minimum free zone as described below.
B
Y
14 12 10 8 6 4 2
161412108 6 4 2 0 2 4 6 810121416 X
A(mm) 30
B(mm) 20
C(mm) 200
h51