HPT 604 series

Submersible Digital Pressure


Level Transducers & Transmitters
Applications
·Level Measurement in Bio-Fuels
·Monitoring of Gasoline & Diesel Fuel Tanks
·Level Measurement in Ballast Tanks
·Level Measurement in Ground Water Level
·Monitoring of Irrigation Equipment
·Control of Pumping Stations

Characters
·MEAS TE pressure cell, 0.25% F.S.,
·Survives Harsh Environments
·EMI/RFI Protection
·Custom level ranges from 50cm to 500m
·Optional PT100 temperature measurement
·IP68 full sealed plastic waterproof design
·CE, RoSH and ATEX Approved
·Custom PU, PE or PTFE cable lengths

Profiles
HPT604 series digital pressure level transducer with high Measuring range
stable and reliable, which use USA TE pressure chips and
high accurate circuit board into the stainless steel housing. Measuring range
Integrated construction and standard signal provide the user
easy and convenient application in the local working place. bar 0 to 0.05 … 0 to 50
The special cable connects with housing, can be immerged inWC 0 to 20 …0 to 20000
into the media for a long time. psi 0 to 1.0…0 to 725
mH2O 0 to 0.5…0 to 500
HPT604 designed incorporating with monolithic computer When choosing the PTFE cable, only measuring ranges up to
technology and sensor digital conversion technology, which 0 ...10 bar, 0 ... 150 psi and 0 ... 100 mH2O are available.
core component adopts 24-bit AD MCU micro-processor to The given measuring ranges are also available in mbar, kPA
ensure high quality of the transducer relaying on its strong and MPa
function and high speed operation capacity.
Materials
The overall designed framework is to meet the requirements Wetted Parts Standard Option
of increasingly enhanced industrial site application with a
view to reliability, stability, high accuracy and the product Case and sensor Stainless steel 316 Ceramic Capacitor
also features strong function and without manually operating
device to ensure good interaction. Application digital signal Protection cap Stainless steel 304 316/PTFE/PVC
processing technology is made for good disturbance immunity.
It’s also feature zero point automatic stable follow up capacity Cable PUR PTFE
and temperature automatic compensation.
Mounting position
Holykell can provide a cost effective solution for level monito- Calibrated in vertical mounting position with pressure connection
ring for a variety of applications. Welcome to your inquiry. facing downwards.

01
Specifications

Ambient Temperature: 25°C (unless specified)

Parameter HPT604
Pressure Range 0-0.05 Bar…..50 Bar / 0-0.5M……..500M H2O Optional (See the P1 page description)

Overload 200% F.S.

Burst Pressure 300% F.S.

Accuracy: ≤ ±0.1%F.S ≤ ±0.15%F.S ≤ ±0.25%F.S


(Linearity Hysteresis Including non-lin., rep. and hys.
Repeatability) Optional
Long Stability Standard: 0.1%F.S±0.05%/Year; Max: 0.15%F.S±0.05%/Year
Working Temp -30℃~80℃ or -40℃~100℃(Customized)
Storage Temp -40℃~125℃
Temperature Standard:-10℃~60℃ or by Customized
Compensation
Medium compatible Compatible with 316L Stainless Steel

Rs485 4~20mA 4~20mA 4~20mA 4~20mA Rs485 Modbus


Output Modbus Hart output level + level + level + Level+
RTU or RS232 4~20mA temp Relay output Temp Output (Ω) RS485 Modbus
10~30 Vdc 12~30 V DC 12~30 V DC 12~30 V DC 12~30 V DC 10~30 Vdc
Power Supply (2.7-5.5Vdc (7-30Vdc (7-30Vdc (7-30Vdc (7-30Vdc (2.7-5.5Vdc
optional) optional) optional) optional) optional) optional)
Polarity protection yes yes yes yes yes yes
Baud rate 9600 (standard), 2400,4800,19200 by customized.
Data format 1 start bit, 8 data bits, 1 stop bit
Sampling rate 10 points/second to 1 point/50 minutes
Resolution 20 bit 10ppm
Insulate resistance >100M Ω @50V dc
Zero Temp. Drift Typical: 0.03%FS/℃, Max: 0.1%FS/℃
FS Temp. Drift Typical: 0.002%FS/℃, Max: 0.1%FS/℃
Electronic connection Fixed cable and water proof IP68
Response time ≤4 to 10 ms (standard); ≤1 ms (Customized)
Pressure Type Gage pressure; Sealed gage and absolute optional.
Certificate approving ATEX intrinsic safety or ExdIICT6, TUV RoHS and CE Certificate approving
EN 61326-1:2013; EN 61326-2-3:2013
EMC Standard
EN 61000-6-2:2005; EN61000-6-4:2007+A1
Lighting Protection None (standard type); Air conducts withstand voltage 8000V Shell and
(optional functions) Cable conduct withstand voltage 4000V. This function is customized.
Cable materials are optional according request, we offer 3 type special cable as follow:
Cable optional
PE Cable(Water Proof); PUR Cable(Oil Proof); PTFE Cable(Anti-Corrosive)
Temperature type PT100, K, J type thermocouple customized.

02
Dimensions and Drawing

Unit: mm

Electronic Connections

Directly sealed cable


Red Vcc+
Rs485 Green 0Vcc-(GND)
RTU
Modbus Yellow RS485A
Black RS485B
S=Signal, Vcc=Power Supply, GND=Vcc-&S-

03
How to Order
1.Range Selection Table:

00 0~0.5 01 0~1.0 02 0~1.1 03 0~1.2 04 0~1.3 05 0~1.4 06 0~1.5 07 0~1.6 08 0~1.7

09 0~1.8 10 0~1.9 11 0~2 12 0~2.1 13 0~2.2 14 0~2.3 15 0~2.4 16 0~2.5 17 0~3

18 0~4 19 0~5 20 0~6 21 0~7 22 0~8 23 0~10 24 0~12 25 0~15 26 0~16

27 0~20 28 0~25 29 0~30 30 0~35 31 0~40 32 0~50 33 0~60 34 0~80 35 0~100

36 0~150 37 0~200 38 0~250 39 0~300 40 0~500 X By Customized

Kindly according to your application select suitable range code , Example: code 19 = 5 .
Unit of measure select on the Part Number Selection Table . Example: Code F=m Fuel , that’s 5m Fuel

2.Part Number Selection Table:

HPT604 19 F G S10 E15 D3 TF 1 002


Selection Type

Pressure Range reference to range selction


Range table code

H=m H2O (Min: 0.5 mH2O; Max:500 mH2O )


F=m Fuel (Min: 0.5 m Fuel; Max:500 m Fuel ) 
Pressure & B=Bar (Min: 0.05Bar Max: 50Bar)
Level Units P=Psi (Min:1Psi; Max:725Psi)
K= kPa (Min:5 kPa; Max:5000 kPa)
I= inWC (Min: 20 inWC; Max: 20000 inWC )
MB= mbar (Min: 50 mbar Max: 50000 mbar)

Pressure type G=Gauge/Relative pressure type (universal)


A=Absolute pressure (customized)

S3=24 V DC (standard) S5=12 V DC S6=5 V DC (for code E11)


S10=12~30 V DC S17=10~30 V DC (for code E11)
Power Supply
S16=2.7-5.5 V DC (for code E11)

E14= 4-20mA + HART 2 wires E11= RS485 MODBUS RTU E12=RS232


E13=I2C Bus E15= RS485 Level + RS485 Temp
Signal Output E21=4-20mA level + 4-20mA Temp E22= 4-20mA level + temp resistive signal
E23= 4-20mA level + Relay output
X= By Customized

CW= Water D1= Diesel, density 0.84 D2= Diesel, density 0.83
Measuring D3= Diesel, density 0.85 D4= Diesel, density 0.86
Medium HW= Max 100 degree C geothermal water
X=Others Liquid and Density By Customized
TF= With Tapered Filter Covers PT= PTFE materials cap
Others Function TA =Titanium alloy materials (high cost!)
(Optional) AN= Anti-corrosion type (high cost!)
LP=Lightning protection AW=Additional weight

Accuracy 1=0.5%F.S. 2=0.25%F.S 3=0.1%F.S (high cost!) 4=0.15%F.S(by customized)

001= Cable 1M 002= Cable 2M 003= Cable 3M


Cable length
XXX= By Customized

04
Accessories

Description Order number


Liquid level display control device
with all kinds of liquid level sensor, measurement according to liquid level,
and according to the setting of the container structure and size and the 0008
density of liquid, calculation, display liquid volume or quality

NPT adapter
The 316 SS G1/2 adapter replaces the removable protective cap and
converts the threads to 1/2”NPT male external, 1/4” female internal 0001
threads.

 4052336
Surge Protector (Lightning Arrestor)1
This DIN rail mounted surge protector is designed to protect PMC 0007
transmitters to a maximum discharge current of 20 kA.

Conduit adapter
0011
316 SS 1/2” NPT male cable conduit adapter.
Must be factory installed

Terminal box
The terminal box, with IP 67 ingress protection and watertight ventilation
element, provides
a moisture-free electrical termination for the submersible pressure 0003
transmitter. It should be
mounted in dry environment or directly in the switch cabinet.

Additional weight
The additional weight increases the dead weight of the submersible pres-
sure transmitter.It simplifies the lowering into monitoring wells, narrow
shafts and deep wells. It effectivelyreduces negative environmental influ- 0009
ences on the measuring result from the measured medium
(e.g. turbulent flow).Stainless steel 316L, approx. 500 g, length (L) 130 mm

Adapter Converter
It is able to convert RS-232 signal to RS-485 balanced differential signal
and extend the communication distance to 1.2km.It uses a particular pump 0005
to gain power from RS-232 signal (RTS, DTR, TXD) without initializing the
RS-232 series interface.This interface converter does this without requi-
ring any AC or DC power.

Desiccant drying cartridge


Desiccant Pack installed on Vented Transducer cable.The cartridge will 0010
have to be field replaced as site environment requires.

Ordering information
Model / Measuring range / Output signal / Temperature measurement / Cable material / Cable length / Case
/ Lightning protection / Accessories

05