P3PC-3192-04EN

ScanSnap N1800 Network Scanner

Getting Started
Contents
Introduction ...........................................................................................................3
■ Manuals .................................................................................................................. 3
■ About This Manual .................................................................................................. 3
■ Warning Indications Used in This Document .......................................................... 4
■ For Safe Use .......................................................................................................... 4
■ Precautions ............................................................................................................. 6
■ Disclaimer of Liability .............................................................................................. 7
■ Regulatory Information ........................................................................................... 7
■ Maintenance ........................................................................................................... 8

Chapter 1 Before Using the Scanner ................................................................9


1.1 From Arrival through Operation .......................................................................... 9
1.2 Checking the Components ................................................................................. 9
1.3 Part Names ...................................................................................................... 10
■ Front view .................................................................................................... 10
■ Rear view ..................................................................................................... 10

Chapter 2 Setting up the Scanner ...................................................................11


2.1 Removing the Protective Packaging ................................................................ 11
2.2 Connecting the Scanner ................................................................................... 11

Chapter 3 Configuring Scanner Basic Settings .............................................12

Chapter 4 Checking the Network Connection ...............................................16

Chapter 5 Downloading the Manual ................................................................17

Appendix A Troubleshooting ...........................................................................18


A.1 Network Connection Troubleshooting .............................................................. 18
■ Checking Basic Network Operation with a Ping Test ................................... 18
■ Failure to Connect to a Server Using Its IP Address ................................... 19
■ Failure to Connect to a Server Using Its Host Name or FQDN .................... 20
■ Failure to Access the Scanner Using a Web Browser, Admin Tool,
or Central Admin Server .............................................................................. 20
A.2 Power Troubleshooting .................................................................................... 22
A.3 Login Troubleshooting ...................................................................................... 22
A.4 Contact for Inquiries ......................................................................................... 22
■ Contact for purchasing the Consumable, Cleaning Materials ...................... 22

Copyright .............................................................................................................23

2
Introduction
Thank you for purchasing the ScanSnap N1800 Network Manual Description
Scanner.
The ScanSnap N1800 is a network image scanner. This ScanSnap N1800 Provides information about
Help (HTML) items on the windows, and
easy-to-operate scanner facilitates the optimal flow of
descriptions and actions to
office work for the workgroup communicating via the take for the messages. Read it
network. as needed.
Scanner Central Provides information about
Trademarks Admin User's Guide scanner central management
Microsoft, Windows, Windows Vista, Windows Server, (PDF) operations and settings.
and Internet Explorer are either registered trademarks or Read it as needed.
trademarks of Microsoft Corporation in the United States
and/or other countries. Accessing the Manuals
Adobe, the Adobe logo, Acrobat, and Reader are either
z The manuals can be accessed by downloading them
registered trademarks or trade names of Adobe Systems from the scanner.
Incorporated in the United States and/or other countries. For more details on how to download the Operator's
ScanSnap and the ScanSnap logo are registered Guide, refer to "Chapter 5 Downloading the Manual"
trademarks or trademarks of PFU LIMITED in Japan. (page 17).
Other company names and product names are the z When the [Help] button is available on the window or
registered trademarks or trademarks of the respective dialog box that is displayed during the operation, you
companies. can open Help by clicking it.
On the LCD touch panel, is displayed as a Help
Manufacturer button.
PFU LIMITED
International Sales Dept., Imaging Business Division, ■ About This Manual
Products Group Solid Square East Tower,
580 Horikawa-cho, Saiwai-ku, Kawasaki-shi Arrow Symbols in This Manual
Kanagawa 212-8563, Japan
Phone: (81-44) 540-4538 Right-arrow symbols (J) are used to connect icons or
menu options you should select in succession.
Example: Select the [Start] menu J [Computer].
© PFU LIMITED 2010-2013

Screen Examples in This Manual


■ Manuals Screenshots in this manual are used according to
guidelines provided by Microsoft Corporation.
Types of Manuals The screen examples in this manual are subject to
The following manuals are prepared for the ScanSnap change without notice in the interest of product
N1800. Read them as needed. improvement.
Manual Description The screen examples used in this manual are of
Windows Vista.
ScanSnap N1800 Provides useful and detailed The actual windows and operations may differ depending
Network Scanner information on the scanner on the operating system. If the actual screen differs from
Getting Started setup and cable connections.
the screen examples in this manual, operate by following
(This Manual) (paper) Read this manual first.
Referred to as "Getting the actual displayed screen.
Started" in this manual.
ScanSnap N1800 Contains further information
Network Scanner about scanner settings,
Operator's Guide scanner administration, and
(PDF) scanner operations, and may
be used as a general
reference.
Referred to as "Operator's
Guide" in this manual.

3
For Windows Server 2012/Windows 8 Abbreviation Name
Users Used
Central Admin Scanner Central Admin Console
To start applications for this product or display Control
Console
Panel, use the All apps screen.
The All apps screen is displayed by following the Central Admin Scanner Central Admin Server
procedure below. Server
1. Right-click the Start screen.
2. Click [All apps] on the app bar. ■ Warning Indications Used in
Example: Windows 8 screen
This Document
The following indications are used in this document to
obviate any chance of accident or damage to you and/or
this product.

WARNING
This indication alerts operators to
an operation that, if not strictly
observed, may result in severe
injury or death.

This indication alerts operators to


CAUTION an operation that, if not strictly
observed, may result in safety
hazards to personnel or damage to
Abbreviations Used in This Manual the product.

The following abbreviations are used in this manual:


A TRIANGLE symbol indicates that special care
Abbreviation Name and attention is required. The drawing inside the
Used triangle shows the specific caution.
Windows XP Windows® XP Home Edition
operating system A CIRCLE with a diagonal line inside shows
Windows® XP Professional actions which users should not perform. It may
operating system also have a drawing inside which shows the
Windows® XP Professional x64 specific action that is not allowed.
Edition operating system A white symbol on black background shows
instructions which users should follow. It may
Windows Vista Windows Vista® Home Basic
operating system (32/64-bit) R also include the drawing that shows the specific
instruction.
Windows Vista® Home Premium
operating system (32/64-bit)
Windows Vista® Business ■ For Safe Use
operating system (32/64-bit)
Windows Vista® Enterprise This manual contains general information regarding
operating system (32/64-bit) safety that must be read before using this product (which
Windows Vista® Ultimate includes the scanner and all associated software and
operating system (32/64-bit) manuals). For the safe use of this product, make sure to
Windows 8 Windows® 8 read the following descriptions.
operating system (32/64-bit) Keep this manual in a safe place so that it can be easily
Windows® 8 Pro referred to when using the scanner.
operating system (32/64-bit) In the following warnings, "power cable" may refer to the
Windows® 8 Enterprise AC cable connected to the AC adapter collectively.
operating system (32/64-bit)
Windows Server Windows Server® 2012 Standard
2012 (64-bit)
Internet Explorer Microsoft® Internet Explorer®
Windows® Internet Explorer®
Adobe Reader Adobe® Reader®
Scanner ScanSnap N1800
Carrier sheet ScanSnap Carrier Sheet
Admin Tool Network Scanner Admin Tool

4
WARNING To avoid injuries, do not place the scanner in an
area where small children may be able to reach.

In one of the following situations, immediately


turn off the scanner, and disconnect the power Before moving the scanner, be sure to
cable from the AC outlet. Not doing so may disconnect any cables connected to it (the power
cause a fire or electric shock. cable, the LAN cable, etc.).
z The scanner is damaged for any reason. Make sure that the floor is free of any
z Smoke or heat coming from the scanner is obstructions.
detected.
z Strange noise or smell is detected. Moving the scanner with the cable connected to
z Foreign objects (water, liquids, small metal the computer may damage the cable, in turn
objects, etc.) get inside the scanner. causing fire, electric shock or injuries.
z Other problems which indicate a scanner Do not touch the power cable with wet hands.
failure are detected.
Doing so may cause an electric shock.
Then, contact your FUJITSU scanner dealer or
an authorized FUJITSU scanner service provider.
Never try fixing such problems by yourself. Doing
so is dangerous. When disconnecting the power cable from the
AC outlet, make sure to hold the power plug and
Do not take apart or modify the scanner as high-
not the cable.
voltage components inside the scanner are
dangerous. Pulling the cable may damage it, which may
cause a fire or electric shock.
PFU assumes no liability to any damage caused
by taking apart the scanner, as doing so is not Do not use the power cable if it is damaged. Also,
covered under the warranty. do not insert any cables or power plugs into loose
sockets. Doing so may cause a fire or electric
The area around the part to which this warning
shock.
label is affixed can become very hot.
Be careful of the following when handling the
To avoid burns, never touch around the area
power cable:
indicated by this label.
z Do not moisten, modify, tie, bundle, or wind
Firmly insert the power cable into the AC outlet. the cable.
Not doing so may cause a fire or the scanner to z Do not place heavy objects on the cable, trap
malfunction. the cable in a doorway, drop or damage the
cable in any other way.
Use the scanner only at the indicated power z Do not pull or forcibly bend or twist the cable.
voltage and current. Do not connect to multiple z Do not place any metal near to the plug of the
power cable.
power strips. Improper power voltage or current
If the power cable is damaged, contact your
might cause a fire or electric shock.
FUJITSU scanner dealer or an authorized
Use only the power cable provided with the FUJITSU scanner service provider.
scanner. Do not use any extension cords. Doing
Do not place heavy objects on the scanner or
so may cause abnormal heat or a fire. Do not use
perform other work on top of the scanner. Doing
the power cable provided with the scanner for
so might cause injuries or an equipment failure.
other devices, since this may cause problems
such as an equipment failure, or an electric
shock. Do not use the scanner or AC adapter while it is
covered, for example, with a blanket. Doing so
Do not install the scanner in the following may raise the temperature inside and cause a
locations which are subject to high temperature, fire.
humidity, less ventilation, or dust. If placed in an
area subject to high temperature, the cover may To avoid injuries, be careful not to get your
become overheated and deformed, resulting in accessories (e.g. ties, necklaces) or hair caught
an electric leakage or fire. inside the scanner.
Use the scanner in a well-ventilated environment.
Do not touch the heated section such as the
z A place near heat-radiating devices such as
bottom of the scanner or AC adapter for a long
stoves or electric heaters, or flammable items
such as volatile inflammable materials or time. Doing so may cause a low-temperature
curtain. burn on your skin.
z A place such as kitchen where oil smoke may When the scanner is not going to be used for a
be formed. long period of time, be sure to disconnect the
z A place such as a bathroom, shower room, or power cable from the AC outlet. Not doing so
swimming pool where it may easily get wet.
may cause a fire or electric shock.
z A place under direct sunlight, in a car under
the scorching sun, or near heating apparatus
where it may get hot.

5
Do not use any aerosol sprays or alcohol based When carrying the scanner outside while it is
sprays to clean the scanner. Dust blown up by raining or snowing, pay special attention so the
strong air from the spray may enter the inside of scanner does not get wet.
the scanner. This may cause the scanner to fail
or malfunction. Sparks, caused by static When you perform cleaning, make sure that the
electricity, generated when blowing off dust and inside of the scanner is free of any foreign
dirt from the outside of the scanner may cause a objects, and be careful not to get your hand or
fire. the cloth caught on the pick spring (metal part) as
Check the following items once a month: a deformed pick spring (metal part) may cause
z The power cable is firmly inserted into the AC injury.
outlet.
z The power cable is not emitting abnormal
heat, or the cable is not rusty or bent. ■ Precautions
z Dust is not accumulated on the power cable
(especially the plug). If so, wipe off any dust READ ALL OF THIS DOCUMENT AND THE
with a soft, dry cloth. OPERATOR'S GUIDE CAREFULLY BEFORE USING
z The power cable does not have any cracks or THIS SCANNER. IF THIS SCANNER IS NOT USED
scratches. CORRECTLY, UNEXPECTED INJURY MAY BE
If any abnormality is detected, contact your
CAUSED TO USERS OR BYSTANDERS.
FUJITSU scanner dealer or an authorized
Also, keep this document in a safe place so that it can be
FUJITSU scanner service provider.
easily referred to during use of this scanner.
While all efforts have been made to ensure the accuracy
of all information in this document, PFU assumes no
CAUTION liability to any party for any damage caused by errors or
omissions or by statements of any kind in this document,
When installing the scanner on a table, make its updates or supplements, whether such errors are
sure that the work surface is flat and stable, and
omissions or statements resulting from negligence,
that none of the scanner's parts extend over the
table edge, otherwise it may fall over or be pulled
accidents, or any other cause.
off the table and cause injuries. PFU further assumes no liability arising from the
application or use of any scanner or system described
Install the scanner away from strong magnetic
herein; nor any liability for incidental or consequential
fields and other sources of electronic noise.
damages arising from the use of this document. PFU
Protect the scanner against any static electricity disclaims all warranties regarding the information
and choose a static-free place to install the
contained herein, whether expressed, implied, or
scanner. Static electricity can cause the scanner
to malfunction.
statutory.
If there is an electrical storm, turn off the scanner,
and disconnect the power cable from the AC
Use of Mercury
outlet. Then, disconnect any connected cables Lamp(s) inside the scanner contain mercury
such as the LAN cable.
Not doing so may destroy the scanner, which
Hg and must be recycled or disposed of
according to local, state, or federal laws.
may damage your property.
Do not supply the power from the AC outlet To avoid unexpected injuries:
where devices requiring high power such as z Do not put the substance contained in the lamp in your
copying machines or paper shredders are mouth as it has mercury.
connected. z Do not breathe the chemical liquid contained in the
Do not block the ventilation ports. Blocking the scanner lamps.
ventilation ports generates heat inside of the z Do not incinerate, crush, or shred the lamps or
scanner, which may result in a fire or scanner scanner parts.
failure.
Do not use the scanner immediately after moving LCD Peculiarities
it from a cold place into a warm room. z The LCD backlight is a fluorescent tube that contains
Condensation may occur, which might lead to some mercury.
scanning errors. Let the scanner dry for one or z Be aware that neither of the following is considered a
two hours before you use it. fault.
When handling documents or the Carrier Sheet, - Despite the advanced technologies used to produce
be careful not to cut your fingers with them. the devices TFT color LCD's, the large number of
pixels involved means that an occasional (always-
on) bright dot or (always-off) dark dot may be visible.
Do not use a damaged Carrier Sheet because it - The characteristics of the LCD mean that there may
may damage or cause the scanner to be some variation in hue and intensity of colors
malfunction. across the screen.

6
Replacing Batteries z Connect the equipment into an outlet on a circuit
different from that to which the receiver is located.
In order to retain data such as BIOS information, this z Consult your dealer or an experienced radio/TV
product has a battery (CMOS RAM battery) on board. technician
FCC warning: Changes or modifications not expressly
approved by the party responsible for compliance could
WARNING
z Do not replace the battery yourself,
as there is a risk of explosion if the void the user's authority to operate the equipment.
wrong type is used. Please contact
your maintenance engineer in NOTICE The use of a shielded interface cable is
charge when the battery runs low. required to comply with the Class B limits of
z Do not touch the battery. Never Part 15 of FCC rules. The length of the
install or remove the battery by power cable must be 3 meters (10 feet) or
yourself. Doing so may cause
less.
electric shock or static electricity
which can damage the device.
Canadian DOC Regulations
Warning Label This digital apparatus does not exceed the Class B limit
for radio noise emissions from digital apparatus set out in
The scanner carries the warning label.
the Radio interference Regulations of the Canadian
Do not remove the warning label from the scanner. Avoid
Department of Communications.
staining the label, so that it is clearly visible.
This Class B digital apparatus complies with Canadian
ICES-003.
■ Disclaimer of Liability Le présent appareil numérique n'émet pas de parasites
radioélectriques dépassant les limites applicables aux
appareils numériques de la classe B et prescrites dans le
Reproducibility of the Scanned Image Règlement sur le brouillage radioélectrique dictées par le
Data Ministère des Communications du Canada.
Confirm that the image data scanned with this product Cet appareil numérique de la classe B est conforme à la
meets your requirements (for example, image norme NMB-003 du Canada.
reproducibility in size accuracy, fidelity, content, colors).
Make sure that there are no missing parts in the scanned Bescheinigung des Herstellers/
image data before disposing of the original document Importeurs
used for scanning.
z Note that when there are sections marked with a Für den Scanner wird folgendes bescheinigt:
highlight pen, the color of the marked section may not z In Übereinsstimmung mit den Bestimmungen der
be accurately reproduced depending on the color and EN45014(CE) funkentstört
density, or may result in a different color tone from the z Maschinenlärminformationsverordnung 3. GPSGV:
original. Der höchste Schalldruckpegel beträgt 70 dB (A) oder
weniger, gemäß EN ISO 7779.
Dieses Gerät wurde nicht für die Benutzung in
■ Regulatory Information unmittelbarer Umgebung starker Lichtquellen (z. B.
Projektoren) konzipiert.
FCC Declaration
ENERGY STAR®
This equipment has been tested and found to comply
with the limits for a Class B digital device, pursuant to PFU Limited, a Fujitsu company, has
Part 15 of the FCC Rules. These limits are designed to determined that this product meets the
provide reasonable protection against harmful ENERGY STAR® guidelines for energy
interference in a residential installation. This equipment efficiency. ENERGY STAR® is a
generates, uses, and can radiate radio frequency energy registered trademark of the United
and, if not installed and used in accordance with the States.
instruction document, may cause harmful interference to
radio communications. Use in High-safety Applications
However, there is no guarantee that interference will not
This product has been designed and manufactured on
occur in a particular installation. If this equipment does
the assumption that it will be used in office, personal,
cause harmful interference to radio or television
domestic, regular industrial, and general-purpose
reception, which can be determined by turning the
applications. It has not been designed and manufactured
equipment off and on, the user is encouraged to try to
for use in applications (simply called "high-safety
correct the interference by one or more of the
applications" from here on) that directly involve danger to
following measures:
life and health when a high degree of safety is required,
z Reorient or relocate the receiving antenna.
for example, in the control of nuclear reactions at nuclear
z Increase the separation between the equipment and
receiver. power facilities, automatic flight control of aircraft, air
traffic control, operation control in mass-transport
systems, medical equipment for sustaining life, and

7
missile firing control in weapons systems, and when
provisionally the safety in question is not ensured. The
user should use this product with adopting measures for
ensuring safety in such high-safety applications. PFU
LIMITED assumes no liability whatsoever for damages
arising from use of this product by the user in high-safety
applications, and for any claims or compensation for
damages by the user or a third party.

■ Maintenance
The user must not perform repairs on the scanner.
PFU assumes no liability to any damage caused by
taking apart the scanner, as doing so is not covered
under the warranty.
Contact your FUJITSU scanner dealer or an authorized
FUJITSU scanner service provider to make repairs to the
scanner.
For contact information, visit the following web page to
find the FUJITSU/PFU office for your country.
http://imagescanner.fujitsu.com/warranty.html
Or, refer to the contact list on the last page of this
document.

8
Chapter 1 Before Using the Scanner
Scanner
1.1 From Arrival through
Operation
The following shows the flow from scanner arrival
through operation.
This manual provides information about Steps 1 to 5
shown below.
For information about Steps 6 to 9, refer to the manuals ADF paper chute
downloaded in Step 5.

1 Check package

D"1.2 Checking the Components" (page 9)


AC cable
2 Setup scanner

D"Chapter 2 Setting up the Scanner" (page 11)


AC adapter
3 Configure scanner basic settings

D"Chapter 3 Configuring Scanner Basic Settings"


(page 12)
LAN cable (straight-through)
4 Check network connection

D"Chapter 4 Checking the Network Connection"


(page 16) Carrier sheet

5 Download manual

D"Chapter 5 Downloading the Manual" (page 17)


Getting Started (this manual)
6 Install Admin Tool

DRefer to the Operator's Guide.

7 Perform scan test Instruction


DRefer to the Operator's Guide.

8 Configure required settings for scanner use

DRefer to the Operator's Guide. EULA Terms for Microsoft®


Windows® XP Embedded and
9 Operate scanner Windows® Embedded Standard

DRefer to the Operator's Guide.


End-User License Agreement
For Network Scanner ScanSnap
N1800 Embedded Software
1.2 Checking the Components
Make sure that all items shown below are included in the
package. If any other packaging is provided, make sure
to store it as well. Make sure to handle the components
with care.
If anything is missing or damaged, contact your FUJITSU
scanner dealer or an authorized FUJITSU scanner
service provider.

9
1.3 Part Names
This section explains names of the scanner parts.

■ Front view
ADF paper chute

Extension

Side guides

Top cover release


catch
Power button
Scan button

LCD touch panel


Top cover
Stacker

■ Rear view

LAN connector
Power connector

Security cable slot

10
Chapter 2 Setting up the Scanner
2. Attach the ADF paper chute.
2.1 Removing the Protective Hold the ADF paper chute with side guides face-up,
Packaging and insert the tabs into the corresponding slots on
the scanner.
The scanner comes with a protective foam sheet and
protective card attached. Follow the procedure described ADF paper chute
below to remove the protective packaging before using
the scanner.
1. Remove the tape and protective foam sheet that
covers the LCD touch panel.
2. Pull the top cover release catch to open the top
cover, and remove the tape and protective card.
Side guides

Tabs
Protective card

Top cover
release catch 3. Connect the AC cable to the AC adapter
(collectively called "power cable").

ATTENTION
Use only the AC adapter and AC cable provided with the
3. Pull the stacker forward, and then remove the scanner.
tape and protective card.

AC adapter

AC cable

4. Connect the cables to the scanner.


Protective
1 Connect the power cable to the scanner's power
card
connector.
2 Connect the LAN cable to the LAN connector.
Stacker

2.2 Connecting the Scanner


1. Place the scanner at its installation site.
1
ATTENTION
The following space is required to set up the scanner: 2
z Depth: 700 mm (28 in.)
z Width: 400 mm (16 in.)
z Height: 500 mm (20 in.) 5. Connect the other end of the LAN cable to the
network hub.
6. Insert the power cable into an AC outlet.
DThe power is connected but the scanner is not yet
ready for operation.

11
Chapter 3 Configuring Scanner Basic
Settings
Do not move or shake the scanner HINT
CAUTION when it is turned on.
This may damage components in
You can select whether or not to display this window again
at the next start up. To display the window again, for "Show
the scanner and cause data to be this message at next start up?", select [Yes]. To not display
lost. this window at next start up, select [No].
To change the setting back to displaying this window at the
next start up, login as the administrator, select [System
Settings] J [Local Settings] J [Language Selection], and
select [Yes] for "Show the "Language Selection" screen at
next start up?".
When the power button is pressed for the first time after
purchase, the window for scanner basic settings appears
automatically. The basic settings for using the scanner
3. Press the [OK] button.
can be configured with this process. DThe scanner is restarted.
When [Yes] is selected for "Show this message at
1. Press the power button on the scanner. next start up?" on the [Language Selection]
window, the [Language Selection] window appears
again.
When [No] is selected for "Show this message at
next start up?" on the [Language Selection]
window, the [Installation Wizard] window appears.
Proceed to Step 5.
4. Check the selected language, and press the
[OK] button.
DThe [Installation Wizard] window appears.
DThe [Language Selection] window appears. 5. Select the items to be specified in the scanner
2. Select a language, and press the [OK] button. basic settings.
The default language is "English (US)". Select the target items to be configured on the
[Installation Wizard] window, and press the [Start]
button.
Lightly touch the button for the target item.
This section shows an example with all items
selected.

ATTENTION
Do not use a pen or other hard object on the LCD touch
panel. The LCD touch panel may be damaged.

HINT
For details about setting items, refer to Help.

To open Help, press .

DThe confirmation window appears for a scanner


restart.

12
6. Set the scanner name. 8. Set the date and time.
On the [Scanner Name] window, specify the scanner On the [Date / Time] window, specify the date format
name and group or domain for joining the network, and the current date and time, and press the [Next]
and press the [Next] button. button.
HINT

z To enter characters, press to show the on-screen

keyboard. The button turns into when the on-


screen keyboard is shown.

z After entering characters, press to hide the on-


screen keyboard.
z The button turns into on a window with no items
requiring characters to be entered.
z For the on-screen keyboard layout, refer to the
Operator's Guide.

9. Specify the login settings.


On the [Login Settings] window, specify the settings
for login, and press the [Next] button.

7. Set the region/timezone.


On the [Region / Timezone] window, select the
region/timezone and whether to apply daylight
saving time, and press the [Next] button.

13
10. Change the admin password. 12. Set the DNS server.
On the [Admin Password] window, specify the On the [DNS Server] window, set the IP address for
administrator password, and press the [Next] button. the DNS server, and press the [Next] button.
The default value for the [Current Password] is
"password".

HINT
If the scanner is not connected to the network, the FQDN
11. Set the scanner's IP address. may not be displayed correctly.
On the [IP Address] window, set the scanner's IP
address, and press the [Next] button. 13. Set the Central Admin Server.
On the [Scanner Central Admin Server] window, set
whether to enable the Central Admin Server and the
Central Admin Server settings, and press the [Finish]
button.

ATTENTION
If DHCP is not used, do not use an IP address that already
exists in the network.
If the same IP address as the specified IP address already
exists, an error occurs.

14
14. Confirm the configured settings.
On the settings confirmation window of the
installation wizard, confirm the configured basic
settings, and press the [OK] button.

DThe wizard finishes and the login window appears.

HINT
z When the scanner name or domain name has been
changed, the scanner is restarted.
z If you select [No] for [Show the Installation Wizard at
next start up?], the [Installation Wizard] window does not
appear immediately after the next scanner startup.

This concludes the scanner basic settings procedure.

HINT
The scanner basic settings can be changed by:
z Changing the settings on the [Installation Wizard]
window
You can display the [Installation Wizard] window by
pressing the [Installation Wizard] button on the [Admin
Settings] window that is displayed by pressing on the
[Admin Menu] window.
z Changing the settings for [System Settings] or [Network
Settings] on the [Admin Menu] window
For details about how to show the [Admin Menu] window,
refer to "Chapter 4 Checking the Network Connection" (page
16).

15
Chapter 4 Checking the Network Connection
This section describes how to check the status of the 3. Select [Network Settings] J [Basic] J [Ping].
network connection.
The network connection can be checked by performing a
ping test from [Admin Menu].
1. Log in to the scanner with the user name and
password of the administrator.
Enter "admin" for [User Name] and the password
specified in the basic settings for [Password]. The
default password is "password".

DThe [Ping] window appears.


4. Check the status of the network connection.
For [Address], enter the IP address, host name, or
FQDN of the computer to be checked.

DThe [Select Mode] window appears.


2. Select the mode and function, and press the
[OK] button.

5. Press the [Ping] button.


DA ping test is performed and the results are
displayed.
If the result shows "Lost=0 (0% loss)", the network
connection is functioning normally.
For any other result, refer to "Checking Basic
Network Operation with a Ping Test" (page 18).
DThe [Admin Menu] window appears.
6. Press .
HINT
DThe [Admin Menu] window appears.
If you specify settings on the [Select Mode] window, the
[Admin Menu] window appears from the next login. 7. Press the [Logout] button to log out of the
scanner.

16
Chapter 5 Downloading the Manual
For this scanner, the Operator's Guide (PDF), which 3. Click the [Save] button.
contains information about scanner settings,
administration, and operations, is provided in addition
with this manual. Read it when using the scanner.
Use Adobe Reader (*) to view the Operator's Guide.
*: Adobe Reader can be downloaded from the following
site.
http://www.adobe.com/
This section describes how to download the manual.
DThe [Save As] dialog box appears.
1. Specify the scanner name or IP address as the
URL using the Web browser (*1) of the ATTENTION
computer to which the manual is to be If Adobe Reader is not installed, and the [Open] button is
pressed, a connection error occurs. To open the file with the
downloaded. [Open] button, install Adobe Reader, and then perform steps
http://scanner_name or IP_address/ 1 to 3 again.
DThe Login window appears.
4. Select a folder, and click the [Save] button.
*1: For this product, use one of the following Web
browsers:
zInternet Explorer 6.0 (Service Pack 2 or later)
(*2)
zInternet Explorer 7 (*2)
zInternet Explorer 8 (*2)
zInternet Explorer 9 (*2)
zInternet Explorer 10 (*2)
*2: Apply the latest security updates. If they are not
applied, you may not be able to download certain
manuals. For Windows XP, the security update
"KB933566" must be applied to Internet Explorer.
If download operations are not possible, clear the
[Do not save encrypted pages to disk] check box on DThe manual is downloaded and saved in the
[Advanced] of [Internet Options] in Internet Explorer, specified folder.
and then try downloading again.
If the Web browser is Internet Explorer 10, configure
[Compatibility View settings] so that the specified
URL is displayed in compatibility view.
2. Click the [Operator's Guide] button.

DThe [File Download] dialog box appears.

17
Appendix A Troubleshooting
A.1 Network Connection [Ping statistics] shows
"Lost=N (1 to 99% loss)"
Troubleshooting
■ Details
■ Checking Basic Network Operation Communication with the device specified as the ping
target is unstable.
with a Ping Test
■ Action
The network connection may be checked by performing
z There may be a quality problem with the LAN cable.
a ping test. For more details on how to perform a ping
Replace the LAN cable and try again.
test, refer to "Chapter 4 Checking the Network
Connection" (page 16). z The network transmission mode may differ from the
Check the ping results, and try the following: connection target. On the [Network Status] window,
change [Link speed / Duplex mode] from [Auto-
Negotiation] to a fixed mode. This can be changed as
[Ping statistics] shows
follows:
"Lost=4 (100% loss)" 1. Select [Network Settings] J [Basic] J [Network
Status].
■ Details DThe [Network Status] window appears.
Communication with the device that is specified as the 2. Select a fixed link speed/duplex mode for [Link
ping target is unavailable. Speed/Duplex Mode].
■ Action 3. Press the [OK] button.
z The setting of the ping target may be invalid. Check
that the ping target IP address, host name, or FQDN "Hardware error."
is correct.
z The network transmission mode may differ from the
■ Details
connection target. On the [Network Status] window, There may be problems in the hardware transmission
change [Link speed / Duplex mode] from [Auto- path. For example, the LAN cable may have become
Negotiation] to a fixed mode. This can be changed as disconnected during the ping test.
follows: ■ Action
1. Select [Network Settings] J [Basic] J [Network Check the status of the LAN cable and try again.
Status].
DThe [Network Status] window appears. "Ping request could not find host
2. Select a fixed link speed/duplex mode for [Link
Speed/Duplex Mode]. xxxxxxxxx. Please check the name and
3. Press the [OK] button. try again."
z If there are no problems with the ping target setting
and the network transmission mode, refer to "Failure ■ Details
to Connect to a Server Using Its IP Address" (page The name-resolution or address-resolution for the
19) for further solutions. device specified as the ping target may have failed.
■ Action
z Check that the ping target host name or FQDN is
correct.
z Check that the DNS server or WINS server settings
are correct.
z If the ping target host name or FQDN is correct, refer
to "Failure to Connect to a Server Using Its Host
Name or FQDN" (page 20) for further solutions.

18
■ Failure to Connect to a Server Another host or communication device
Using Its IP Address is connected using the same IP address
If a server cannot be connected to by using its IP as the scanner.
address, or if a scanner does not respond to a ping test
by specifying its IP address, try the following:
■ Action
If the same IP address has already been used by
another host or communication device, then even if the
Connection error between the server
other device has been given a different IP address the
and scanner. Or there is a problem with server may not recognize the scanner's "duplicate" IP
the LAN cable. address until it is rebooted. Restart the server.
If a duplicate IP address connection from another host or
■ Action communication device exists on a LAN, both it will be
Check that the LAN cable is connected to both the unusable.
scanner and server correctly. If a duplicate IP address connection from another host or
If the server is connected using a LAN cable (straight communication device exists, pull out its LAN cable and
type), in case Auto MDI/MDI-X (automatic selection) is restart the server.
not supported, a LAN cable (crossover type), switch, or
router is required between the scanner and server. Access is denied due to the
If this is not the case, the LAN cable may be faulty. Use establishment of a firewall between the
a LAN cable that functions normally and try again.
server and the scanner.
IP address or subnet mask is invalid. ■ Action
If a firewall is established between the server and the
■ Action
scanner, check that it is not set to deny access to the
On the [IP Address] window, check that the IP address
network.
or subnet mask settings are correct.
The [IP Address] window can be displayed as follows:
Link speed/duplex mode for the network
1. Select [Network Settings] J [Basic] J [IP Address].
differs between the scanner and server.
When using DHCP, the DHCP server Or the server does not support
does not operate normally. Or there is a automatic negotiation.
problem with the DHCP server settings.
■ Action
Link speed/duplex mode for the network of the scanner
■ Action
is set to the default setting [Auto-Negotiation].
If using DHCP, on the [Network Status] window, check
On the [Network Status] window, match the scanner and
that IP address, subnet mask, and default gateway
server's network link speed/duplex mode settings. If the
settings are all correct.
problem persists in spite of having set both the scanner
If these settings are not correct, the DHCP server may
and server's network link speed/duplex settings to [Auto-
not operate normally, or the DHCP server may not
Negotiation], select something other than [Auto-
assign valid IP addresses because of restricted number
Negotiation] and check again.
of leases or MAC address validation.
On the [Network Status] window, change [Link speed/
Check the DHCP server connection status and the
Duplex Mode] from [Auto-Negotiation] to a fixed mode.
details of the server settings.
This can be changed as follows:
The [Network Status] window can be displayed as
follows: 1. Select [Network Settings] J [Basic] J [Network Status].
DThe [Network Status] window appears.
1. Select [Network Settings] J [Basic] J [Network Status].
2. Select a fixed link speed/duplex mode for [Link Speed/
Duplex Mode].
3. Press the [OK] button.

19
■ Failure to Connect to a Server ■ Failure to Access the Scanner
Using Its Host Name or FQDN Using a Web Browser, Admin Tool,
If the scanner cannot connect to a server by specifying or Central Admin Server
its host name or FQDN, or if a server does not respond
If access is not possible when attempting to connect to
to a ping test by specifying its host name or FQDN, try
the scanner using a Web browser, the Admin Tool, or the
the following:
Central Admin Server, or when attempting to connect to
the Central Admin Server from the Central Admin
Same as in "Failure to Connect to a Console, try the following:
Server Using Its IP Address" (page 19).
Same as in "Failure to Connect to a
■ Action
Server Using Its IP Address" (page 19).
Check if a network connection is possible by trying the
same solution for "Failure to Connect to a Server Using ■ Action
Its IP Address" (page 19).
Check if a network connection is possible by trying the
same solution for "Failure to Connect to a Server Using
The scanner's DNS server or WINS Its IP Address" (page 19).
server settings are invalid.
■ Action The DNS or WINS server does not
Check that the DNS and WINS server settings are operate normally. Or the scanner name
correct. is not registered in the DNS or WINS
server.
The DNS or WINS server does not
operate normally. Or an error occurred ■ Action
Specify the IP address and check the connection.
on the network path to the DNS or WINS If it is possible to connect the scanner using the Admin
server. Tool with a specified IP address, specify the scanner's
IP address in the DNS or WINS server.
■ Action Check the DNS or WINS server settings on the Web
Ping the DNS or WINS server to check that they are browser and Admin Tool.
functioning normally.
If the DNS or WINS server is not functioning, request the A misconfigured firewall between the
network administrator to check its status.
scanner and the computer installed with
the Web browser or Admin Tool
(connected via LAN) is denying access
with the HTTP/HTTPS protocol.
■ Action
If there is a firewall between the scanner and the
computer installed with the Web browser or Admin Tool,
check that it is not set to deny access to the network.

20
The URL of the target scanner is not The scanner is in standby mode.
registered as a trusted site.
■ Action
■ Action Press the power button to start the scanner.
Set the scanner URL as a trusted site for Internet
Explorer. A proxy server is being used.
1. In Internet Explorer, select the [Tools] menu J [Internet
Options].
■ Action
Set the proxy server not to be used.
2. On the [Security] tab, select [Trusted sites] and press
the [Sites] button. 1. In Internet Explorer, select the [Tools] menu J [Internet
Options].
3. Enter the URL of the scanner in the [Add this website to
the zone] field, and press the [Add] button. 2. Press the [LAN settings] button on the [Connections]
tab.
3. Clear the [Use a proxy server for your LAN (These
In Internet Explorer, the security level for settings will not apply to dial-up or VPN connections)]
the target zone is set to [High] on the check box.
[Security] tab in the [Tools] menu -
[Internet Options]. There is an error with the connection
In [Custom Level], [Prompt] or [Disable] protocol setting.
is set for [Active scripting] under
■ Action
[Scripting] in the [Settings] area. Check if SSL is enabled on the [Admin Connection]
window.
■ Action
The [Admin Connection] window can be displayed as
When connecting using the scanner name, the
follows:
connection will be an intranet connection. When
connecting using an IP address, it will be an internet 1. Select [Network Settings] J [Network Admin] J [Admin
connection. Connection].
Try the following settings for the corresponding zone.
1. In Internet Explorer, select the [Tools] menu J [Internet There is an error with the port number
Options]. setting.
2. Enable [Active scripting] in either of the following ways:
- On the [Security] tab, click the [Default level] button ■ Action
to set [Security level for this zone] to [Medium]. Check the specified port number on the [Admin
- On the [Security] tab, click the [Custom level] Connection] window.
button to set to [Enable] for [Active scripting] under The [Admin Connection] window can be displayed as
[Scripting] in the [Settings] area. follows:
3. If connecting via the Internet zone, on the [Privacy] tab, 1. Select [Network Settings] J [Network Admin] J [Admin
set the level to [Medium High] or below. Connection].
4. Delete all temporary internet files with either of the
following methods. In Internet Explorer, [Tools] menu -
- For Internet Explorer 6.0 (Service Pack 2 or later) [Internet Options] - [Advanced] tab, the
On the [General] tab, click the [Delete Files] button
for [Temporary Internet files]. [Use SSL 3.0] check box under
- For Internet Explorer 7 [Security] in the [Settings] area is not
On the [General] tab, click the [Delete] button for selected.
[Browsing history], and click the [Delete files]
button for [Temporary Internet Files]. ■ Action
- For Internet Explorer 8 or Internet Explorer 9 1. In Internet Explorer, select the [Tools] menu J [Internet
On the [General] tab, click the [Delete] button for
Options].
[Browsing history], select the [Temporary Internet
files] check box, and click the [Delete] button. 2. On the [Advanced] tab, select the [Use SSL 3.0] check
- For Internet Explorer 10 box under [Security] in the [Settings] area.
On the [General] tab, click the [Delete] button for
[Browsing history], select the [Temporary Internet
files and website files] check box, and click the
[Delete] button.

21
A.2 Power Troubleshooting A.3 Login Troubleshooting
Scanner cannot be turned on. Cannot login with administrator
password.
■ Check item
Has the power button been pressed? ■ Check item
■ Action Was the Caps Lock on when the password
Press the power button. was entered?
■ Action
Turn off the Caps Lock and try logging in again.
■ Check item
If the password has been lost or forgotten, contact your
Are the AC cable and AC adapter properly FUJITSU scanner dealer or an authorized FUJITSU
connected to the scanner? scanner service provider.
■ Action
z Connect the AC cable and the AC adapter properly.
z Disconnect power cable from the scanner to turn off A.4 Contact for Inquiries
the scanner, and connect the cable again. After If a solution to your problem cannot be found in the
turning the power off, wait for at least 10 seconds above troubleshooting list, refer to the following web
before turning the power back on again. page:
If the problem persists even after taking the above http://scansnap.fujitsu.com/g-support/en/index.html
mentioned actions, contact your FUJITSU scanner If the solution to your problem cannot be found on the
dealer or an authorized FUJITSU scanner service above web page, refer to the contact information for your
provider. Fujitsu office on the following web page:
http://imagescanner.fujitsu.com/warranty.html

■ Contact for purchasing the


Consumable, Cleaning Materials
http://scansnap.fujitsu.com/

22
Copyright
NetAdvantage Redistribution and use in source and binary forms are permitted provided that the
above copyright notice and this paragraph are duplicated in all such forms and
that any documentation, advertising materials, and other materials related to such
Copyright© 2000-2010 Infragistics, Inc.
distribution and use acknowledge that the software was developed by the
University of California, Berkeley. The name of the University may not be used to
LEADTOOLS for .NET endorse or promote products derived from this software without specific prior
written permission.
Copyright © 2005 LEAD Technologies, Inc.
THIS SOFTWARE IS PROVIDED "AS IS" AND WITHOUT ANY EXPRESS OR
IMPLIED WARRANTIES, INCLUDING, WITHOUT LIMITATION, THE IMPLIED
WinPcap WARRANTIES OF MERCHANTIBILITY AND FITNESS FOR A PARTICULAR
PURPOSE.
Copyright © 1999 - 2005 NetGroup, Politecnico di Torino (Italy).
Copyright © 2005 - 2010 CACE Technologies, Davis (California). Portions Copyright © 1995, 1996, 1997 Kungliga Tekniska Hogskolan (Royal
All rights reserved. Institute of Technology, Stockholm, Sweden).
All rights reserved.
Redistribution and use in source and binary forms, with or without modification,
are permitted provided that the following conditions are met: Redistribution and use in source and binary forms, with or without modification,
1. Redistributions of source code must retain the above copyright notice, are permitted provided that the following conditions are met:
this list of conditions and the following disclaimer. 1. Redistributions of source code must retain the above copyright notice,
2. Redistributions in binary form must reproduce the above copyright notice, this list of conditions and the following disclaimer.
this list of conditions and the following disclaimer in the documentation 2. Redistributions in binary form must reproduce the above copyright notice,
and/or other materials provided with the distribution. this list of conditions and the following disclaimer in the documentation
3. Neither the name of the Politecnico di Torino, CACE Technologies nor the and/or other materials provided with the distribution.
names of its contributors may be used to endorse or promote products 3. All advertising materials mentioning features or use of this software must
derived from this software without specific prior written permission. display the following acknowledgement: "This product includes software
developed by the Kungliga Tekniska Hogskolan and its contributors."
THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND 4. Neither the name of the University nor the names of its contributors may
CONTRIBUTORS "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, be used to endorse or promote products derived from this software
INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF without specific prior written permission.
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE
DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT OWNER OR
THIS SOFTWARE IS PROVIDED BY THE INSTITUTE AND CONTRIBUTORS
CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL,
"AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT
SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT
NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND
NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES;
FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT
LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)
SHALL THE INSTITUTE OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT,
HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN
INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL
CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR
DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF
OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE,
SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS;
EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY
OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT
This product includes software developed by the University of California, (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF
Lawrence Berkeley Laboratory and its contributors. THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF
This product includes software developed by the Kungliga Tekniska Hogskolan SUCH DAMAGE.
and its contributors.
This product includes software developed by Yen Yen Lim and North Dakota State Portions Copyright © 1997 Yen Yen Lim and North Dakota State University.
University. All rights reserved.

Portions Copyright © 1990, 1991, 1992, 1993, 1994, 1995, 1996, 1997 The Redistribution and use in source and binary forms, with or without modification,
Regents of the University of California. are permitted provided that the following conditions are met:
All rights reserved.
1. Redistributions of source code must retain the above copyright notice,
this list of conditions and the following disclaimer.
Redistribution and use in source and binary forms, with or without modification,
are permitted provided that the following conditions are met: 2. Redistributions in binary form must reproduce the above copyright notice,
this list of conditions and the following disclaimer in the documentation
1. Redistributions of source code must retain the above copyright notice, and/or other materials provided with the distribution.
this list of conditions and the following disclaimer.
3. All advertising materials mentioning features or use of this software must
2. Redistributions in binary form must reproduce the above copyright notice, display the following acknowledgement: "This product includes software
this list of conditions and the following disclaimer in the documentation developed by Yen Yen Lim and North Dakota State University"
and/or other materials provided with the distribution.
4. The name of the author may not be used to endorse or promote products
3. All advertising materials mentioning features or use of this software must derived from this software without specific prior written permission.
display the following acknowledgement: "This product includes software
developed by the University of California, Berkeley and its contributors."
THIS SOFTWARE IS PROVIDED BY THE AUTHOR "AS IS" AND ANY
4. Neither the name of the University nor the names of its contributors may EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO,
be used to endorse or promote products derived from this software THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
without specific prior written permission. PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE
AUTHOR BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL,
THIS SOFTWARE IS PROVIDED BY THE INSTITUTE AND CONTRIBUTORS EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT
"AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES;
NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)
FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN
SHALL THE REGENTS OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR
INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE,
DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS;
OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY Portions Copyright © 1993 by Digital Equipment Corporation.
OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT
(INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF
Permission to use, copy, modify, and distribute this software for any purpose with
THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF
or without fee is hereby granted, provided that the above copyright notice and this
SUCH DAMAGE.
permission notice appear in all copies, and that the name of Digital Equipment
Corporation not be used in advertising or publicity pertaining to distribution of the
Portions Copyright © 1983 Regents of the University of California. All rights document or software without specific, written prior permission.
reserved.

23
THE SOFTWARE IS PROVIDED "AS IS" AND DIGITAL EQUIPMENT CORP.
DISCLAIMS ALL WARRANTIES WITH REGARD TO THIS SOFTWARE, WinDump
INCLUDING ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND
Copyright © 1999 - 2005 NetGroup, Politecnico di Torino (Italy).
FITNESS. IN NO EVENT SHALL DIGITAL EQUIPMENT CORPORATION BE
LIABLE FOR ANY SPECIAL, DIRECT, INDIRECT, OR CONSEQUENTIAL Copyright © 2005 - 2006 CACE Technologies, Davis (California).
DAMAGES OR ANY DAMAGES WHATSOEVER RESULTING FROM LOSS OF All rights reserved.
USE, DATA OR PROFITS, WHETHER IN AN ACTION OF CONTRACT,
NEGLIGENCE OR OTHER TORTIOUS ACTION, ARISING OUT OF OR IN Redistribution and use in source and binary forms, with or without modification,
CONNECTION WITH THE USE OR PERFORMANCE OF THIS SOFTWARE. are permitted provided that the following conditions are met:
1. Redistributions of source code must retain the above copyright notice,
Portions Copyright © 1995, 1996, 1997, 1998, and 1999 WIDE Project. this list of conditions and the following disclaimer.
All rights reserved. 2. Redistributions in binary form must reproduce the above copyright notice,
this list of conditions and the following disclaimer in the documentation
Redistribution and use in source and binary forms, with or without modification, and/or other materials provided with the distribution.
are permitted provided that the following conditions are met: 3. Neither the name of the Politecnico di Torino, CACE Technologies nor the
1. Redistributions of source code must retain the above copyright notice, names of its contributors may be used to endorse or promote products
this list of conditions and the following disclaimer. derived from this software without specific prior written permission.
2. Redistributions in binary form must reproduce the above copyright notice,
this list of conditions and the following disclaimer in the documentation THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND
and/or other materials provided with the distribution. CONTRIBUTORS "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES,
INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF
3. Neither the name of the project nor the names of its contributors may be
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE
used to endorse or promote products derived from this software without
DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT OWNER OR
specific prior written permission.
CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL,
SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT
THIS SOFTWARE IS PROVIDED BY THE PROJECT AND CONTRIBUTORS NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES;
"AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)
NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN
FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR
SHALL THE PROJECT OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE,
INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF
SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS;
OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY This product includes software developed by the University of California,
OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT Lawrence Berkeley Laboratory and its contributors.
(INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF
THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF
SUCH DAMAGE. Secure iNetSuite
Copyright© 2008 Dart Communications
Portions Copyright © 1996 Juniper Networks, Inc. All rights reserved.

Redistribution and use in source and binary forms, with or without modification,
are permitted provided that: (1) source code distributions retain the above
copyright notice and this paragraph in its entirety, (2) distributions including binary
code include the above copyright notice and this paragraph in its entirety in the
documentation or other materials provided with the distribution.
The name of Juniper Networks may not be used to endorse or promote products
derived from this software without specific prior written permission.

THIS SOFTWARE IS PROVIDED "AS IS" AND WITHOUT ANY EXPRESS OR


IMPLIED WARRANTIES, INCLUDING, WITHOUT LIMITATION, THE IMPLIED
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR
PURPOSE.

Portions Copyright © 2001 Daniel Hartmeier. All rights reserved.

Redistribution and use in source and binary forms, with or without modification,
are permitted provided that the following conditions are met:
z Redistributions of source code must retain the above copyright notice, this list
of conditions and the following disclaimer.
z Redistributions in binary form must reproduce the above copyright notice, this
list of conditions and the following disclaimer in the documentation and/or
other materials provided with the distribution.

THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND


CONTRIBUTOR "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES,
INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE
DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDERS OR
CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL,
SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT
NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES;
LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)
HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN
CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR
OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE,
EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.

Portions Copyright 1989 by Carnegie Mellon.

Permission to use, copy, modify, and distribute this program for any purpose and
without fee is hereby granted, provided that this copyright and permission notice
appear on all copies and supporting documentation, the name of Carnegie Mellon
not be used in advertising or publicity pertaining to distribution of the program
without specific prior permission, and notice be given in supporting
documentation that copying and distribution is by permission of Carnegie Mellon
and Stanford University. Carnegie Mellon makes no representations about the
suitability of this software for any purpose. It is provided "as is" without express or
implied warranty.

24

You might also like