Nothing Special   »   [go: up one dir, main page]

3RQ20002AW00 Datasheet en

Download as pdf or txt
Download as pdf or txt
You are on page 1of 5

Data sheet 3RQ2000-2AW00

Coupling relay in industrial enclosure 1 changeover contact Wide voltage range 24


V to 240 V AC/DC Spring-type terminals

product brand name SIRIUS


product designation Coupling relay in industrial enclosure
product type designation 3RQ2
General technical data
product feature protective coating on printed-circuit board No
consumed active power 1.5 W
insulation voltage for overvoltage category III according to IEC 300 V
60664 with degree of pollution 3 rated value
degree of pollution 3
surge voltage resistance rated value 4 kV
maximum permissible voltage for protective separation
● between auxiliary and auxiliary circuit 300 V
● between control and auxiliary circuit according to IEC 300 V
60947-1
protection class IP IP20
shock resistance
● according to IEC 60068-2-27 11g / 15 ms
● for railway applications according to EN 61373 Category 1, Class B
switching behavior monostable
mechanical service life (operating cycles) typical 10 000 000
electrical endurance (operating cycles) at AC-15 at 230 V 100 000
typical
thermal current of the switching element with contacts 5A
maximum
reference code according to IEC 81346-2 K
Substance Prohibitance (Date) 05/31/2018
SVHC substance name Lead - 7439-92-1
Lead monoxide (lead oxide) - 1317-36-8
Control circuit/ Control
control supply voltage 1 at AC
● at 50 Hz 24 ... 240 V
● at 60 Hz 24 ... 240 V
control supply voltage 1 at DC
● 24 ... 240 V
operating range factor control supply voltage rated value at
DC
● initial value 0.7
● full-scale value 1.1
operating range factor control supply voltage rated value at
AC at 50 Hz
● initial value 0.7
● full-scale value 1.1

3RQ20002AW00 Subject to change without notice


7/2/2024
Page 1/5 © Copyright Siemens
operating range factor control supply voltage rated value at
AC at 60 Hz
● initial value 0.7
● full-scale value 1.1
ON-delay time
● at AC maximum 10 ms
● at DC maximum 10 ms
OFF-delay time maximum 100 ms
Switching Function
design of the switching function CO contact
Mechanical data
product component plug-in socket No
design of the relay operating mechanism poled
Short-circuit protection
design of the fuse link for short-circuit protection of the auxiliary fuse gL/gG: 6 A
switch required
Auxiliary circuit
material of switching contacts AgSnO2
number of NC contacts for auxiliary contacts 0
number of NO contacts for auxiliary contacts 0
number of CO contacts for auxiliary contacts 1
contact reliability of auxiliary contacts one incorrect switching operation of 100 million switching operations (17 V, 5
mA)
type of voltage AC/DC
ampacity of the output relay at AC-15
● at 24 V at 50/60 Hz 3A
● at 110 V at 50/60 Hz 3A
● at 250 V at 50/60 Hz 3A
ampacity of the output relay at DC-13
● at 24 V 1A
● at 125 V 0.2 A
● at 250 V 0.1 A
Electromagnetic compatibility
EMC emitted interference according to IEC 60947-1 ambience A (industrial sector)
EMC immunity according to IEC 60947-1 corresponds to degree of severity 3
conducted interference
● due to burst according to IEC 61000-4-4 2 kV
● due to conductor-earth surge according to IEC 61000-4-5 2 kV (line to ground)
● due to conductor-conductor surge according to IEC 1 kV (line to line)
61000-4-5
field-based interference according to IEC 61000-4-3 10 V/m
electrostatic discharge according to IEC 61000-4-2 4 kV contact discharging, 8 kV air discharging
Connections/ Terminals
product component removable terminal for auxiliary and Yes
control circuit
type of electrical connection spring-loaded terminal (push-in)
type of connectable conductor cross-sections
● solid 0.5 ... 4 mm²
● finely stranded with core end processing 0.5 ... 2.5 mm²
● for AWG cables solid 20 ... 12
connectable conductor cross-section
● solid 0.5 ... 4 mm²
● finely stranded with core end processing maximum 2.5 mm²
● finely stranded without core end processing minimum 0.5 mm²
AWG number as coded connectable conductor cross
section
● solid 12 ... 20
● stranded 12 ... 20
stripped length of the cable for auxiliary and control contacts 10 mm
Installation/ mounting/ dimensions
mounting position any
fastening method screw and snap-on mounting onto 35 mm DIN rail

3RQ20002AW00 Subject to change without notice


7/2/2024
Page 2/5 © Copyright Siemens
height 100 mm
width 22.5 mm
depth 90 mm
Ambient conditions
installation altitude at height above sea level maximum 2 000 m
ambient temperature
● during operation -40 ... +60 °C
● during storage -40 ... +80 °C
● during transport -40 ... +80 °C
relative humidity during operation 10 ... 95 %
Approvals Certificates
General Product Approval

Confirmation

EMV Test Certificates Marine / Shipping

KC Type Test Certific-


ates/Test Report

Marine / Shipping other Railway Environment

Confirmation Confirmation Environmental Con-


firmations

Further information
Information on the packaging
https://support.industry.siemens.com/cs/ww/en/view/109813875
Information- and Downloadcenter (Catalogs, Brochures,…)
https://www.siemens.com/ic10
Industry Mall (Online ordering system)
https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3RQ2000-2AW00
Cax online generator
http://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3RQ2000-2AW00
Service&Support (Manuals, Certificates, Characteristics, FAQs,...)
https://support.industry.siemens.com/cs/ww/en/ps/3RQ2000-2AW00
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)
http://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3RQ2000-2AW00&lang=en
Characteristic: Derating
https://support.industry.siemens.com/cs/ww/en/ps/3RQ2000-2AW00/manual

3RQ20002AW00 Subject to change without notice


7/2/2024
Page 3/5 © Copyright Siemens
A1 (+)

11

-K
A2 (-)

12

14

last modified: 4/3/2024

3RQ20002AW00 Subject to change without notice


7/2/2024
Page 4/5 © Copyright Siemens
3RQ20002AW00 Subject to change without notice
7/2/2024
Page 5/5 © Copyright Siemens

You might also like