3UG46321AW30 Datasheet en
3UG46321AW30 Datasheet en
3UG46321AW30 Datasheet en
Product Function
Product function
● undervoltage detection Yes
● Overvoltage detection Yes
● Overvoltage detection 1 phase Yes
● Overvoltage detection 3 phase No
● Overvoltage detection DC Yes
● undervoltage detection 1 phase Yes
● undervoltage detection 3 phases No
● undervoltage detection DC Yes
● Voltage window recognition 1 phase Yes
● Voltage window recognition 3 phase No
● Voltage window recognition DC Yes
● Adjustable open/closed-circuit current principle Yes
● External reset Yes
● Auto-reset Yes
Measuring circuit
Measurable line frequency 40 ... 500 Hz
Measurable voltage at DC 10 ... 600 V
Adjustable response delay time
● with lower or upper limit violation 0.1 ... 20 s
Accuracy of digital display +/-1 digit
Relative temperature-related measurement deviation 0.1 %
Precision
Relative metering precision 5 %
Auxiliary circuit
Number of NC contacts
● delayed switching 0
Number of NO contacts
● delayed switching 0
Number of CO contacts
● delayed switching 1
Operating frequency with 3RT2 contactor maximum 5 000 1/h
Main circuit
Number of poles for main current circuit 1
Outputs
Operating current at 17 V minimum 5 mA
Continuous current of the DIAZED fuse link of the 4 A
output relay
Electromagnetic compatibility
Conducted interference
● due to burst acc. to IEC 61000-4-4 2 kV
● due to conductor-earth surge acc. to IEC 2 kV
61000-4-5
● due to conductor-conductor surge acc. to IEC 1 kV
61000-4-5
Field-bound parasitic coupling acc. to IEC 61000-4-3 10 V/m
Electrostatic discharge acc. to IEC 61000-4-2 6 kV contact discharge / 8 kV air discharge
Galvanic isolation
Design of the electrical isolation Protective separation
Connections/ Terminals
Product function
● removable terminal for auxiliary and control Yes
circuit
Type of electrical connection screw-type terminals
Type of connectable conductor cross-sections
● solid 1x (0.5 ... 4 mm2), 2x (0.5 ... 2.5 mm2)
● finely stranded with core end processing 1x (0.5 ... 2.5 mm2), 2x (0.5 ... 1.5 mm2)
● at AWG conductors solid 2x (20 ... 14)
● at AWG conductors stranded 2x (20 ... 14)
Connectable conductor cross-section
● solid 0.5 ... 4 mm²
● finely stranded with core end processing 0.5 ... 2.5 mm²
AWG number as coded connectable conductor cross
section
● solid 20 ... 14
● stranded 20 ... 14
Tightening torque
● with screw-type terminals 1.2 ... 0.8 N·m
Ambient conditions
Installation altitude at height above sea level
● maximum 2 000 m
Certificates/ approvals
General Product Approval EMC Declaration of Conformity
Miscellaneous
Further information
Information- and Downloadcenter (Catalogs, Brochures,…)
www.siemens.com/ic10
Industry Mall (Online ordering system)
https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3UG4632-1AW30
Cax online generator
http://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3UG4632-1AW30
Service&Support (Manuals, Certificates, Characteristics, FAQs,...)
https://support.industry.siemens.com/cs/ww/en/ps/3UG4632-1AW30
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)
http://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3UG4632-1AW30&lang=en