PT.

TRAKINDO UTAMA - Kavling Komersial Taman Tekno Blok B No 1,


Sector XI BSD City, Tangerang 15317, Indonesia

PHONE: +62 21 2905 8900 Ext. 2905, Call Center 1500 228

Email: sos.manager@trakindo.co.id

TRANSMISSION POWER EQUIP NUM: HD10-048 SERIAL NUMBER: KDP00926


SHIFT CAT 777E
J21A-54206-0430 Action Required Interp By: Nurul Lita Anastina
LABEL#: 0F63
Interpreted On: 24-Jul-24
SAMPLE SHIP TIME (days) : 7
The Iso Code Slightly Above Acceptable Clean Lines Range (Clean Lines Target = 18/15). Fe Increased. Probably Pump, Gear, Shaft,
SATRIA BAHANA SARANA Bearing, Spline Or Clutch Plates Wear. Suggest To Check Oil Pressure, Transmission Performance Test, Check And Clean Magnetic
PT. Screen. Make Necessary Repairs. Advise To Change Oil. Take Oil Samples At 250 Hour Intervals To Monitor Condition.

0F63 - TANJUNG ENIM - SATRIA


BAHANA SARANA PT.
LOCATION: BANKO BARAT

REGION: SOUTHERN
SUMATERA-PALEMBANG
RECEIVED DATE: 23-Jul-24

BRANCH REC DT: 20-Jul-24

Iso Code Sedikit Di Atas Target Tingkat Kebersihan. (Target Tingkat Kebersihan = 18/15). Elemen Fe Meningkat. Kemungkinan
Keausan Pada Gear, Shaft, Bearings, Spline Dan Clutch Plate. Disarakankan Untuk Memeriksa Tekanan Oli, Tes Performa
Transmisi, Periksa Dan Bersihkan Magnetic Screen. Segeralah Lakukan Perbaikan. Dianjurkan Ganti Oli. Ambil Sampel Setelah 250
Jam Untuk Memonitor.

SAMPLE INFORMATION For additional sample history, go to: S.O.S WEB

OIL CONDITION AND PHYSICAL/CHEMICAL TEST


17-Jul-24 25-Feb-24 09-Feb-24 18-Jan-24 17-Jul-24 25-Feb-24 09-Feb-24 18-Jan-24
Sampled Date
Sample Id J21A-54206-0430 J21A-54064-0210 J21A-54048-0935 J21A-54030-0531 VISCOSITY AT 100°C (Centistokes)
Lab Date 24-Jul-24 04-Mar-24 17-Feb-24 30-Jan-24 V100 Viscosity at 100 C 11.39 11.10 11.04 10.50
Meter [Hr] 14377.0 12540.0 12483.0 12148.0
Comp Meter [Hr] 14377.0 12540.0 12483.0 12148.0
Meter On Fluid 1894.0 57.0 335.0 1095.0
WATER CONTAMINATION
Fluid Brand PERTAMINA PERTAMINA PERTAMINA PERTAMINA
W Water N N N N
Fluid Weight 30 30 30 30
Fluid Type TRANSLIK HD TRANSLIK HD TRANSLIK HD TRANSLIK HD
Fluid Change Y N Y Y
Filter Change Y Y Y Y PARTICLE QUANTIFIER INDEX

Total Fluid Added


0 0 0 0 PQI PQ Index 0 0 24 0

PARTICLE COUNT AND OTHER ANALYSIS


17-Jul-24 25-Feb-24 09-Feb-24 18-Jan-24
WEAR METAL/CONTAMINANT/ADDITIVES PARTICLE COUNT (Count/mL)
17-Jul-24 25-Feb-24 09-Feb-24 18-Jan-24 3523 4547 3637 4696
6µ 6µ
ELEMENTS (ppm) 26 57 72 188
14µ 14µ
Cr Chromium 0 0 0 0
ISO6 ISO6 19 19 19 19
Pb Lead 0 0 0 0
ISO14 ISO14 12 13 13 15
Fe Iron 20 17 16 38
Cu Copper 2 1 1 5
VISUAL
Al Aluminum 1 1 1 1 - - LQF MIX -
PCV PC Visual
Sn Tin 0 0 0 0
Ni Nickel 0 0 0 0
B Boron 3 2 2 1
K Potassium 1 1 0 1
Na Sodium 0 0 1 0
Si Silicon 5 7 8 8
Ca Calcium 3344 3272 3549 3150
P Phosphorus 792 754 838 770
Zn Zinc 1076 970 1049 1025
Mg Magnesium 15 14 16 15
Mo Molybdenum 4 1 2 1

Notice: This analysis is intended as an aid in predicting mechanical wear. No guarantee, expressed or implied, is made against failure of this piece of equipment or component
Oil Analysis Report Page 1 of 2
TRANSMISSION POWER SHIFT
J21A-54206-0430
SERIAL NUMBER: KDP00926
EQUIP NUM: HD10-048
Action Required
CAT 777E

Report Comment
THE ANALYSIS PROVIDED ARE INDICATIVE OF CONDITIONS BASED UPON SAMPLE INFORMATION RECEIVED AND THE QUALITY OF SAMPLE SUPPLIED.
RECOMMENDATIONS ARE PROVIDED AS A GUIDE ONLY. ANY DECISION TO REPAIR COMPONENTS IS ENTIRELY AT THE CUSTOMER'S DESCRETION. KINDLY ADVISE
YOU TO CONTACT US PRIOR TO 7 DAYS AFTER REPORT RELEASE SHOULD YOU NEED FURTHER DISCUSSION ABOUT THIS SAMPLE. ----- ANALISA INI BERSIFAT
INDIKASI, BERDASARKAN INFORMASI DARI LABEL & SAMPLE YG DI KIRIMKAN. JIKA ADA KEPUTUSAN PERBAIKAN COMPONENT SEPENUHNYA KEBIJAKAN CUSTOMER.
DISARANKAN AGAR DISKUSI LEBIH LANJUT MENGENAI SAMPLE INI HARUS DILAKUKAN SEBELUM 7 HARI DARI TANGGAL LAPORAN DI TERBITKAN.

Result Explanation Section

Notice: This analysis is intended as an aid in predicting mechanical wear. No guarantee, expressed or implied, is made against failure of this piece of equipment or component
Oil Analysis Report Page 2 of 2

You might also like