Nothing Special   »   [go: up one dir, main page]

Ats 4 100HD - en

Download as pdf or txt
Download as pdf or txt
You are on page 1of 13

Please, read this manual carefully Manual

before use!

EN

AUTOMATIC TRANSFER
SWITCH (ATS)
KS ATS 4/100HD
KS ATS 4/100HD-O
PREFACE
Thank you for your purchase of ATS from Könner & Söhnen®. This manual contains safety instructions, a
description of the use and commissioning of the ATS and procedures for its maintenance.
The manufacturer reserves the right to make changes in the product design, configuration and construction.
The images and drawings in this manual are for reference only and may differ from the actual components
and inscriptions on the products.
Contact information that you are free to use in case of any problems can be found at the end of this
manual. All information in this manual is correct to the best of our knowledge and belief at the date
of its publication. The current list of service centers can be found on the official importer’s website:
www.koenner-soehnen.com
In order to ensure equipment integrity and avoid possi-
PLEASE NOTE! ble injuries, we recommend that you read this manual
before operating the product.

ATS UNIT USE AND SAFETY PRECAUTIONS 1


WORK AREA
Do not use the product near flammable gases, liquids or dust. Keep the work area clean and well lit to avoid
injuries. Keep unauthorized persons, children and animals away from the running product.

ELECTRICAL SAFETY
The product is energized. Observe safety precautions to avoid electric shock. Avoid operating the product
in high-humidity environments. Do not allow moisture to enter the product, as this increases the risk of
electric shock. Avoid direct contact with grounded surfaces (pipes, radiators, etc.). Be careful when working
with the power cord. Replace it immediately in case of damage, as damaged power cord increases the risk
of electric shock. All product connections must be carried out by a certified electrician in accordance with
all electrical codes and regulations. Do not operate the product with your feet in the water, on wet or damp
soil. Do not touch live parts of the product. Keep all electrical equipment dry and clean. Replace damaged
or worn wiring. Worn, damaged, or rusted terminals must be replaced as well.

PERSONAL SAFETY
Do not operate the product when you are tired or under the influence of potent drugs, alcohol or
medication. During operation, inattention can cause serious injury. Make sure there are no foreign objects
on the product when it is turned on. Do not overload the product; use it for its intended purpose only.

The total power of power consumers connected to the


PLEASE NOTE! ATS system must not exceed the maximum permissible
power for this ATS unit model.

WARNING!

This material is for informational purposes only and is not an instruction how to install or
connect equipment to the network. In practice, there are different options for supplying
electricity and different rules for its connection. The decision on how to properly connect the
equipment in each individual case must be made by a certified electrician who performs the
installation and electrical connection of the equipment. The manufacturer is not responsible
for improper connection of equipment, and is not responsible for possible material and
physical damage that may occur as a result of improper installation, connection or operation
of equipment.
konner-sohnen.com | 1
SPECIFICATIONS 2
Model KS ATS 4/100HD KS ATS 4/100HD-O
Consumption 18W 18W
Operating voltage 230 V/400 V 230 V/400 V
Power 230 V, kVA, cosPhi 1.0 23 кW 23 кW
Current (max) 230 V 100 A 100 A
Power 400 V, kVA, cosPhi 0.8 55 кW 55 кW
Current (max) 400 V 100A 100A
Working environment -20-45 0 С humidity: ≤ 50%
Storage environment -30-70 0 С humidity: ≤ 50%
IP protection class IP44
Insulation class AC1.0KV/1min 1mA
Net dimensions (LxWxH), mm 500x300x600 515x415x150
Net weight, kg 22.3 5

GENERAL VIEW OF THE ATS UNITS 3


1. Main power input bars: used for fixed the
2 main power саblе or busbar
2. Standby power input bars: used for fixed
the main power саblе or busbar
3 3. Working power fuses
4
5 4. Electronic control unit of transfer switch:
including main control circuit board and
driven motor.
5. Terminal #2: Transferring control signal
intput (passive output)
6. Terminal #3: Position feedback control
1 signal output 1 (active output for M type
and passive output for)
12 7. Terminal #1: Electronic control unit power
supply input
11 10 9 8 7 6 8. LED indicators

9. Electric/emergency manual mode selection button


10. Switch position status indicator
11. Manual emergency handle interface: used to tum the switch manually to switchover the power supply
at an emergency situation.
12. Transferring switch bоdу: the standard type is equipped with upper incoming lines and lower busbar
outgoing lines.

konner-sohnen.com | 2
13. S afety guard plate installation holes,
used for fixing the safety guard plate
14. R ight installation bracket: matched with
the lefl installation bracket and used for
fixing switches
15. L oad power output bars: used for fixing
installation the load cables or busbars.
16
16. L efl installation bracket: matched with
the right installation bracket and used
for fixing switches
15
13
14

Manufacturer reserves the right to make changes and/or


improvements in design, components set and technical
IMPORTANT! attributes without notice and without incurring obliga-
tion. The pictures in this manual are schematical and may
not match the parameters of original product.

CONTROLLER MAIN TECHNICAL PARAMETERS 4


Conventional thermal current ith 100A
Rated insulation voltage of copper bar, Ui 750V
Rated impulse withstand voltage, Uimp 8 kV
Rated operating voltage of copper bar, Ue AC440V
Use category АС-ЗА
Rated operating current of copper bar, Іе 100
Rated making capacity 10Іе (10 times the rated current)
Rated breaking capacity 8le (8 times the rated current)
Rated limit short-circuit current 100 kА
Rated short time withstand current 9 kА
Transferring time І - II or II - І 0.45 s

Standard product: AC220V,


Rated operating voltage of the control
Optional: DC24V, АС110V, AC280V,
power supply, Us
Correct working range: 85% Us ~ 115% Us

Start 300W
Normal 55W
Net weight (4-роІе), kg 3.5

konner-sohnen.com | 3
SCHEMATIC DIAGRAM OF CORRECT
INSTALLATION METHOD 5

BEST RIGHT
(front installation) (back installation)

RIGHT WRONG
(vertical installation) (inverted installation)

ENVIRONMENTAL REQUIREMENTS FOR USE 6


Name Requirements
-20 То +45°С, the average value for 24 hours
Operating temperature
shall not exceed +35°С;

The average humidity under the +40°С conditions shall not


Operating humidity
exceed 50% without condensation;

Lower than 2000 meters and, if higher than 2000 meters,


Altitude
reduce its rated value for use:

There shall bе no stroпg vibration or shock апd nо harmful


Vibration and gas gases to corrode the metals аnd to damage the iпsulation
within the environment of its use;

There shall bе nо serious dust, conductive particles or


Surrounding material
explosive hazardous substances
Class of pollution Class III
ІР rating IP20
То bе stored under -З0 То 70°С and in а dry, non-corrosive
Storage requirements and saline environment and the longest period of storage
shall bе 1 year

konner-sohnen.com | 4
DIMENSIONS 7

Maximum size Other detailed dimensions


Current lnstallation data of the bоdу of switch
range
LF WF HF LM WM HM A B C D E F
100A 225 7 84 244 135 136 113 103 14 6 102.5 21

Reference
Other detailed dimensions of switch dimensions
G H J K L M N O P Q X Y Z
30 133 13 141 2.5 18 8 86 37 86 113 303.5 168.5 208

Х, У and Z аrе the maximum width, depth and height of


NOTE!
the switch assembled with а manual emergency handle.
Depending оn the angle of the handle when installing ог the difference of positions of the
slider moving, the corresponding dimensions will Ье smaller than the data listed in thetable
above, which аге listed for reference only.

INPUT AND OUTPUT СОРРЕR BАR


DIMENSIONS CHART 18

14

konner-sohnen.com | 5
TERMINAL FUNCTIONS INTRODUCTION 8
Terminal Access point Function Notes
Serial № serial №
Power supply neutral wire for feedback Active output, 1 А
101, 106 and live wire output AC230V
Terminal №1 operaling power supply live wire and
102, 103 >5А АС 230V
№1 neutral wire input
№2 operaling power supply live wire and
104, 105 >5А АС 230V
neutral wire input
Passive control when disconnected and See SКТ Туре РгіnсірІе
201, 206 active control when closed 0iagram for delails
Extemal passive control signal input
202 common terminal
Terminal
№2 203 Line І is switched оn, when closed with 202
Passive control signals
204 Line 0 is switched оn, when closed with 202

205 Line IІ is switched оn, when closed with 202

301, 306 Not used, directly connected internally 20А-250А Unassembled

Passive position feedback signal output


302 common terminal
М type is active output,
Terminal Closed with 302, the other types are
303
№3 when Line І is switclled оn passive output, see the
Closed with 302, principle diagram for
304 details 1А АС 220V 400A
when Line 0 is switclled оn
and above assembly
Closed with 302,
305 when Line ІI is switclled оn

TERMINAL
LOCATION DRAWING
Х type 100А

konner-sohnen.com | 6
INSTRUCTIONS FOR USE OF LED INDICATORS 9
№1 №2
Line І control power supply is powered- Line І control
on. (Тhere is АС 220V between the access power supply
points 102 and 103 of No.1 tenninal) fuse is normal.

№3 №4 №5 №6
Line І control relay 125А-250А switch, key lock or
Line II control
is normal (the relay power supply button is in the AUTO position (the
is mounted оп the is powered-on Line II control key lock оr the button is mounted
internal circuit board power supply оn the front side of the switch).
(Тhere is AC 230V
and No.3 light is used fuse is 400A-3200A switch and Line II
between the
for this function, оnІу normal. control rеІау аrе normal (the relay
access points 104
when No.4 light is not is mounted оn the internal circuit
and 105).
Ііt up). board).

INSTRUCTIONS FOR RAPID APPLICATION ОF LED INDICATORS:


А. No. 1 and No. 4 indicator lights are lit up, which
stands for that the control power supply оІ the lines І
and II are powered оn.
В. No. 2 and No. 5 indicator lights are Ііt up, which
stands for that the fuses of the control power supply
of the lines І and II are normal.
С. No. 3 indicator light is lit up, which stands for that
the control relay оІ the line І is working normally.
D. No. 6 indicator light for the 400А to 3200А switches
is lit up, which stands for that the control rеІау of the
Ііnе II is working normally.
Е. No. 6 indicator light for the 125А to 250А switches
is lit up, which stands for that the key switch or the
button is in the ON position.

NOTE! М type switch 100А has no LED indicator equipped.

konner-sohnen.com | 7
INTERNAL PRINCIPLE DIAGRAM 10

The above drawing is only a shematic diagram of its


NOTE! working principle, which does not represent the number
of its internal components.

konner-sohnen.com | 8
WARRANTY PROVISIONS 11
The international manufacturer warranty is 1 year. The warranty period starts from the date of purchase.
In cases when warranty period is longer than 1 year according to local legislation please contact your local
dealer. The Seller which sells the product is responsible for granting the warranty. Please contact the Seller
for warranty. Within the warranty period, if the product fails because of defects in the production process,
it will be exchanged on the same product or repaired.
The warranty card should be kept throughout the warranty period. In case of warranty card loss, a second
one will not be provided. The customer must provide the warranty card and buyer`s check during request
for repair or exchange. Otherwise, the warranty service will not be provided. The warranty card, attached to
the product during sale, should be correctly and fully completed by the retailer and customer, signed and
stamped. In other cases, warranty is not considered as valid.
Provide clean product to the service center. Parts, that must be replaced, are the property of the service
center.

WARRANTY DOES NOT COVER:


- Mechanical damage (cracks, paint peeling, etc.) and damage caused by the action of aggressive media,
ingress of foreign objects into the product or air inlet screen, as well as damage resulting from improper
storage (corrosion of metal parts).
- Malfunctions resulting from improper operation, unintended use of the product, overloading of the
product, as well as instability of the mains parameters. The product overload is indicated by melting or
discoloration of parts due to the effect of high temperature, score marks on the cylinder or piston surfaces,
destruction of connecting rod inserts or piston rings. In addition, the warranty obligations do not apply to
the failure of the automatic voltage regulator of power generators due to improper operation.
- Malfunctions caused by contamination of the fuel or cooling system.
- Quick-wearing parts (V-belts, rubber seals, spark plugs, nozzles, clutch springs, pulleys, guide rollers,
cables, manual starters, clamping chucks, collets, removable batteries, filter and safety elements, oil, re-
movable devices, fittings, blades, drills, etc.).
- Electric cables with mechanical and thermal damage.
- The product tampered with or repaired not by the authorized service center. The product tampered with
or repaired not by the authorized service center is indicated by, among other things, kinked splined parts
of fasteners.
- Preventive maintenance (cleaning, washing, greasing, etc.), installation and setup of the product.
- Normal wear and tear of the product (remaining life).
- Malfunctions arising from the use of the product for business related purposes.
- The warranty card that is not filled out or does not bear the seller’s seal.
- The warranty card that does not bear the bearer’s signature.
- The warranty will become null and void in case of violation of the rules for the operation, transportation
and storage of the generator.
- Improper or careless installation, improper connection to the mains.

konner-sohnen.com | 9
ANNEX

ONE-PHASE ATS ATS CONNECTION TERMINAL


Fig. 1

konner-sohnen.com | 10
ANNEX

THREE-PHASE ATS ATS CONNECTION TERMINAL


Fig. 2

konner-sohnen.com | 11
CONTACTS
Deutschland:
DIMAX International GmbH
Flinger Broich 203 -FortunaPark-
40235 Düsseldorf, Deutschland
www.koenner-soehnen.com
Ihre Bestellungen
orders@dimaxgroup.de
Kundendienst, technische Fragen
und Unterstützung
support@dimaxgroup.de
Garantie, Reparatur und Service
service@dimaxgroup.de
Sonstiges
info@dimaxgroup.de

Polska:
DIMAX International
Poland Sp.z o.o.
Polska, Warczawska,
306B 05-082 Stare Babice,
info.pl@dimaxgroup.de

Україна:
ТОВ «Техно Трейд КС»,
вул. Електротехнічна 47, 02222,
м. Київ, Україна
sales@ks-power.com.ua

You might also like