KONGSBERG PROPRIETARY: This document contains KONGSBERG information which is proprietary and confidential. Any disclosure, copying, distribution or use is prohibited if not otherwise explicitly agreed with KONGSBERG in writing. Any authorised reproduction in whole or in part, must include this legend. © 2015 KONGSBERG – All rights reserved.
Chapter 1
K-Chief 600 functional description(standard
alarm and monitoring system)
• Alarm detection:
Instrument failure, Low-Low, Low, High, High-High, filters on signal,
time delay on alarm and return status, line broken, line short. Alarm state
indication.
• Alarm Inhibition:
inhibit source, time delay for inhibition situation.
• Alarm and monitoring display:
Alarm pages: alarm group, active alarms, alarm history.
Monitoring pages: group display, tag details, custom view.
Chapter 1
K-Chief 600 functional description(standard
alarm and monitoring system)
• Alarm events:
Parameters enter an alarm state. Handling of events.
Watch Calling System:
Extend the alarm information to accommodation area where the duty
engineer is.
Set duty engineer/officer
Transfer duty watch to bridge.
• Access and control transfer:
Equipment control must be only available from one location at a time.
• User interface:
Topbar, alarm side bar, Navigation line, operator dialogues , tabular
views, process views, custom views, trend views.
Chapter 1
K-Chief 600 functional description(standard
alarm and monitoring system)
Chapter 1
K-Chief 600 functional description(standard
alarm and monitoring system)
• SCU
• DGU
• RAi-16xe,RAi-10tcxe,
• RAo-8xe,
• RDi-32xe,RDi-32Axe,
• RDo-16xe
Chapter 3
K-Chief 600 system main hardware components
• SCU:
• Functions
Features
• Responsible for routing data, both • Standard Fast Ethernet, 100Base-X
real-time and service-data. Fast Ethernet.
• Alarm system including local • Industrial Ethernet, POWERLINK,
timestamp. is CANopen over Ethernet with
real-time capabilities (optional).
• Programmable Logical Controller
• CANopen maritime (CiA 307).
• (KM Flexi modules). • Communication line redundancy.
• Pre-programmed logic • No serviceable parts inside module
and remote control of ship • All connections are plugable.
• auxilliary equipment and power • Easy hardware replacement:
Software and configuration
management.
download to DPU’s on local CAN
Chapter 3
K-Chief 600 system main hardware components
Chapter 3
K-Chief 600 system main hardware components
• RAi-16xe
Chapter 3
K-Chief 600 system main hardware components
K-Chief 600
Alarm Philosophy
Alarm Priorities, Colours and
Buttons
Emergency alarm – requires immediate action
Alarm – requires action
Warning – requires attention
Info (caution ) – requires attention (lowest priority)
Inhibit – alarm is blocked by process.
Offscan – alarm is blocked by operator
Invalid - alarm cannot be presented due missing
communication to the DPU.
The top bar and alarm lines will always be accessible. Hence it is not
possible to cover the top bar by for example dialogues.
Alarm side bar Dock
Alarm groups can be docked and undocked to show group information
When Acknowledge
Alarms in Tabular
view - Active Alarms,
all visible Alarms will
be Acknowledged
Active Alarms
Ship@Web applications:
• Viewer
• Trend
• Report Designer
• Report Generator