Et200sp DQ 8x24vdc 0 5a ST Manual en-US en-US
Et200sp DQ 8x24vdc 0 5a ST Manual en-US en-US
Et200sp DQ 8x24vdc 0 5a ST Manual en-US en-US
___________________
Documentation guide 1
___________________
2
SIMATIC Product overview
___________________
3
ET 200SP ___________________
Wiring up
(6ES7132-6BF01-0BA0)
5
Manual ___________________
Interrupts/diagnostics alarms
6
___________________
Technical specifications
A
___________________
Parameter data record
02/2019
A5E03574575-AF
Legal information
Warning notice system
This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent
damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert
symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are
graded according to the degree of danger.
DANGER
indicates that death or severe personal injury will result if proper precautions are not taken.
WARNING
indicates that death or severe personal injury may result if proper precautions are not taken.
CAUTION
indicates that minor personal injury can result if proper precautions are not taken.
NOTICE
indicates that property damage can result if proper precautions are not taken.
If more than one degree of danger is present, the warning notice representing the highest degree of danger will
be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to
property damage.
Qualified Personnel
The product/system described in this documentation may be operated only by personnel qualified for the specific
task in accordance with the relevant documentation, in particular its warning notices and safety instructions.
Qualified personnel are those who, based on their training and experience, are capable of identifying risks and
avoiding potential hazards when working with these products/systems.
Proper use of Siemens products
Note the following:
WARNING
Siemens products may only be used for the applications described in the catalog and in the relevant technical
documentation. If products and components from other manufacturers are used, these must be recommended
or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and
maintenance are required to ensure that the products operate safely and without any problems. The permissible
ambient conditions must be complied with. The information in the relevant documentation must be observed.
Trademarks
All names identified by ® are registered trademarks of Siemens AG. The remaining trademarks in this publication
may be trademarks whose use by third parties for their own purposes could violate the rights of the owner.
Disclaimer of Liability
We have reviewed the contents of this publication to ensure consistency with the hardware and software
described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the
information in this publication is reviewed regularly and any necessary corrections are included in subsequent
editions.
Conventions
CPU: When the term "CPU" is used in this manual, it applies to the CPUs of the S7-1500
automation system as well as to the CPUs/interface modules of the distributed I/O system
ET 200SP.
STEP 7: In this documentation, "STEP 7" is used as a synonym for all versions of the
configuration and programming software "STEP 7 (TIA Portal)".
Please also observe notes marked as follows:
Note
A note contains important information on the product described in the documentation, on the
handling of the product or on the section of the documentation to which particular attention
should be paid.
Security information
Siemens provides products and solutions with industrial security functions that support the
secure operation of plants, systems, machines and networks.
In order to protect plants, systems, machines and networks against cyber threats, it is
necessary to implement – and continuously maintain – a holistic, state-of-the-art industrial
security concept. Siemens’ products and solutions constitute one element of such a concept.
Customers are responsible for preventing unauthorized access to their plants, systems,
machines and networks. Such systems, machines and components should only be
connected to an enterprise network or the internet if and to the extent such a connection is
necessary and only when appropriate security measures (e.g. firewalls and/or network
segmentation) are in place.
For additional information on industrial security measures that can be implemented, please
visit (http://www.siemens.com/industrialsecurity).
Siemens' products and solutions undergo continuous development to make them more
secure. Siemens strongly recommends that product updates are applied as soon as they are
available and that the latest product versions are used. Use of product versions that are no
longer supported, and failure to apply the latest updates may increase customers' exposure
to cyber threats.
To stay informed about product updates, subscribe to the Siemens Industrial Security RSS
Feed visit (http://www.siemens.com/industrialsecurity).
Preface ................................................................................................................................................... 3
1 Documentation guide .............................................................................................................................. 6
2 Product overview .................................................................................................................................. 10
2.1 Properties ................................................................................................................................10
3 Wiring up .............................................................................................................................................. 12
3.1 Wiring and block diagram .......................................................................................................12
4 Parameters/address space ................................................................................................................... 15
4.1 Parameters .............................................................................................................................15
4.2 Explanation of the parameters ................................................................................................17
4.3 Address space ........................................................................................................................18
5 Interrupts/diagnostics alarms ................................................................................................................. 20
5.1 Status and error display ..........................................................................................................20
5.2 Interrupts .................................................................................................................................22
5.3 Diagnostics alarms ..................................................................................................................22
6 Technical specifications ........................................................................................................................ 23
6.1 Technical specifications ..........................................................................................................23
A Parameter data record .......................................................................................................................... 28
A.1 Parameter assignment and structure of the parameter data record .......................................28
Basic information
The system manual describes in detail the configuration, installation, wiring and
commissioning of the SIMATIC ET 200SP. distributed I/O system. The STEP 7 online help
supports you in the configuration and programming.
Device information
Product manuals contain a compact description of the module-specific information, such as
properties, wiring diagrams, characteristics and technical specifications.
General information
The function manuals contain detailed descriptions on general topics regarding the SIMATIC
ET 200SP distributed I/O system, e.g. diagnostics, communication, Web server, motion
control and OPC UA.
You can download the documentation free of charge from the Internet
(https://support.industry.siemens.com/cs/ww/en/view/109742709).
Changes and supplements to the manuals are documented in a Product Information.
You can download the product information free of charge from the Internet
(https://support.industry.siemens.com/cs/us/en/view/73021864).
"mySupport"
With "mySupport", your personal workspace, you make the most of your Industry Online
Support.
In "mySupport" you can store filters, favorites and tags, request CAx data and put together
your personal library in the Documentation area. Furthermore, your data is automatically
filled into support requests and you always have an overview of your current requests.
You need to register once to use the full functionality of "mySupport".
You can find "mySupport" in the Internet (https://support.industry.siemens.com/My/ww/en).
"mySupport" - Documentation
In the Documentation area of "mySupport", you have the possibility to combine complete
manuals or parts of them to make your own manual.
You can export the manual in PDF format or in an editable format.
You can find "mySupport" - Documentation in the Internet
(https://support.industry.siemens.com/My/ww/en/documentation).
Application examples
The application examples support you with various tools and examples for solving your
automation tasks. Solutions are shown in interplay with multiple components in the system -
separated from the focus in individual products.
You can find the application examples on the Internet
(https://support.industry.siemens.com/sc/ww/en/sc/2054).
PRONETA
With SIEMENS PRONETA (PROFINET network analysis), you analyze the plant network
during commissioning. PRONETA features two core functions:
● The topology overview independently scans PROFINET and all connected components.
● The IO check is a fast test of the wiring and the module configuration of a system.
You can find SIEMENS PRONETA on the Internet
(https://support.industry.siemens.com/cs/ww/en/view/67460624).
SINETPLAN
SINETPLAN, the Siemens Network Planner, supports you in planning automation systems
and networks based on PROFINET. The tool facilitates professional and predictive
dimensioning of your PROFINET installation as early as in the planning stage. In addition,
SINETPLAN supports you during network optimization and helps you to exploit network
resources optimally and to plan reserves. This helps to prevent problems in commissioning
or failures during productive operation even in advance of a planned operation. This
increases the availability of the production plant and helps improve operational safety.
The advantages at a glance
● Network optimization thanks to port-specific calculation of the network load
● Increased production availability thanks to online scan and verification of existing systems
● Transparency before commissioning through importing and simulation of existing STEP 7
projects
● Efficiency through securing existing investments in the long term and optimal exploitation
of resources
You can find SINETPLAN on the Internet (https://www.siemens.com/sinetplan).
Article number
6ES7132-6BF01-0BA0 (number in package unit: 1 unit)
6ES7132-6BF01-2BA0 (number in package unit: 10 units)
Properties
The module has the following technical properties:
● Digital output module with 8 outputs
● Supply voltage L+
● Output current 0.5 A per channel
● Source output (PNP)
● Configurable diagnostics (per module)
● Configurable substitute values (per channel)
● Suitable for solenoid valves, DC contactors, and indicator lights
● Safety-related shutdown
The module supports the following functions:
Accessories
The following accessories must be ordered separately:
● Labeling strips
● Color identification labels
● Reference identification label
● Shield connector
See also
You can find additional information on the accessories in the ET 200SP distributed I/O
system (http://support.automation.siemens.com/WW/view/en/58649293) system manual.
Note
The load group of the module must begin with a light-colored BaseUnit. Keep this in mind
also during the configuration.
Note
Cross circuit at output
Be aware that voltage from a cross-circuit at the output can feed L+ to modules.
Figure 3-1 Block diagram and terminal assignment for 1- and 2-wire connection of actuators
1 Due to the limited number of parameters of a maximum of 244 bytes per ET 200SP station with a PROFIBUS GSD
configuration, the parameter assignment options are restricted. The parameter length of the I/O module is 4 bytes with
PROFIBUS GSD configuration. If necessary, you can set this parameter by using the data record 128, see the appendix
"Parameter data record".
Note
If both parameters "Diagnostics: short-circuit to L+" and "Diagnostics: wire break" are
enabled and one of these diagnostic events occurs, the affected channel is switched off to
avoid triggering an undefined load and the corresponding diagnostic alarm.
If both parameters "Diagnostics: short-circuit to L+" and "Diagnostics: wire break" are
enabled and one of these diagnostic events occurs, the affected channel is switched off to
avoid triggering an undefined load and the corresponding diagnostic alarm.
If the parameter "Diagnostics: short-circuit to L+" is enabled and "Diagnostics: wire break" is
disabled, the signal status is retained at the affected channel when "Diagnostics: short-circuit
to L+" occurs. A diagnostic alarm is triggered only for 0 signal.
Diagnostics short-circuit to L+
Enabling of the diagnostics if a short-circuit of the actuator supply to L+ occurs.
Note
If one of the two parameters "Diagnostics: Short-circuit to L+" or "Diagnostics: Wire break" is
enabled and one of these diagnostics occurs, the affected channel is switched off. This
prevents undefined load switching and supports detection of a faulty channel for module
diagnostics.
Channel activated
Determines whether a channel is enabled or disabled.
Potential group
A potential group consists of a group of directly adjacent I/O modules within an ET 200SP
station, which are supplied via a common supply voltage.
A potential group begins with a light-colored BaseUnit through which the required voltage is
supplied for all modules of the potential group. The light-colored BaseUnit interrupts the
three self-assembling voltage buses P1, P2 and AUX to the left neighbor.
All additional I/O modules of this potential group are plugged into dark-colored BaseUnits.
You take the potential of the self-assembling voltage buses P1, P2 and AUX from the left
neighbor.
A potential group ends with the dark-colored BaseUnit, which follows a light-colored
BaseUnit or server module in the station configuration.
Configuration Short designation/module Configuration software, e.g. with STEP 7 (TIA Portal)
name in the GSD file Integrated in hardware GSD file GSD file
catalog STEP 7 PROFINET IO PROFIBUS DP
1 x 8-channel without value DQ 8x24VDC 0.5A ST V14, SP1 or higher with X X
status V0.0 HSP 0222
1 x 8-channel with value DQ 8x24VDC 0.5A ST V14, SP1 or higher with X ---
status V0.0, QI HSP 0222
Address space
The following figure shows the assignment of the address space for the
DQ 8×24VDC/0.5A ST with value status (Quality Information (QI)). The addresses for the
value status are only available if the value status is enabled.
LED display
DQ 8x24VDC/0.5A ST.
① DIAG (green/red)
② Channel status (green)
③ PWR (green)
DIAG LED
PWR LED
5.2 Interrupts
The digital output module DQ 8x24...24VDC/0.5A ST supports diagnostic interrupts.
Diagnostics interrupt
The module generates a diagnostics interrupt for the following events:
● Short-circuit
● Wire break
● Parameter assignment error
● No supply voltage
Table 5- 4 Diagnostics alarms, their meaning and how to deal with them
Engineering with
• STEP 7 TIA Portal configurable/integrated V14
as of version
• PROFIBUS as of GSD version/GSD revi- One GSD file each, Revision 3 and 5 and higher
sion
• PWM No
• Oversampling No
• MSO No
Redundancy
• Redundancy capability Yes
Hardware configuration
Automatic encoding Yes
• Mechanical coding element Yes
Digital outputs
Type of digital output Source output (PNP, current-sourcing)
Number of digital outputs 8
Current-sourcing Yes
Digital outputs, parameterizable Yes
Short-circuit protection Yes
• Response threshold, typ. 1A
• upper limit 12 kΩ
Output voltage
• for signal "1", min. L+ (-0.8 V)
Switching frequency
• with resistive load, max. 100 Hz
– up to 40 °C, max. 4A
– up to 50 °C, max. 4A
– up to 60 °C, max. 4A
vertical installation
– up to 30 °C, max. 4A
– up to 40 °C, max. 4A
– up to 50 °C, max. 4A
Cable length
• shielded, max. 1 000 m
Isochronous mode
Isochronous operation (application synchro- No
nized up to terminal)
Interrupts/diagnostics/status information
Diagnostics function Yes
Substitute values connectable Yes
Alarms
• Diagnostic alarm Yes
Potential separation
Potential separation channels
• between the channels No
Ambient conditions
Ambient temperature during operation
• horizontal installation, min. -30 °C
Safety-related shutdown
Note
The digital output module DQ 8x24VDC/0.5A ST supports safety-related shutdown in
connection with a fail-safe power module F-PM-E 24VDC/8A PPM ST:
• SIL according to IEC 61508: 2
• Highest attainable safety class in safety mode, performance level according to
EN ISO 13849-1: d
Note
Residual current for signal state "0"
Due to the Diagnostics: Wire break function, there is a low level of residual current in the "0"
signal state at the output, which may cause the display diodes to flicker.
This residual current does not depend on the setting for the Diagnostics: Wire break
parameter.
Dimension drawing
See manual ET 200SP BaseUnits
(http://support.automation.siemens.com/WW/view/en/58532597/133300)
Note
Channel 0 contains the diagnostics for the entire module.
Header information
The figure below shows the structure of the header information.
Parameters
The figure below shows the structure of the parameters for channels 0 to 7.
You enable a parameter by setting the corresponding bit to "1".