___________________

Preface

___________________
Guide to the documentation 1

SIMATIC
___________________
New properties 2

___________________
Product overview 3
ET 200SP
BaseUnits ___________________ 4
(6ES7193-6BP.../3RK1908-0AP00…) BaseUnits for I/O modules
___________________
BaseUnits for motor starters 5
Manual

___________________
Potential distributor modules 6

___________________
Dimension drawings of I/O
modules A

___________________
Dimension drawings of motor
starters B

___________________
Dimension drawings of the
potential distributor modules 7

02/2018
A5E03727049-AJ
Legal information
Warning notice system
This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent
damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert
symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are
graded according to the degree of danger.

DANGER
indicates that death or severe personal injury will result if proper precautions are not taken.

WARNING
indicates that death or severe personal injury may result if proper precautions are not taken.

CAUTION
indicates that minor personal injury can result if proper precautions are not taken.

NOTICE
indicates that property damage can result if proper precautions are not taken.
If more than one degree of danger is present, the warning notice representing the highest degree of danger will
be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to
property damage.
Qualified Personnel
The product/system described in this documentation may be operated only by personnel qualified for the specific
task in accordance with the relevant documentation, in particular its warning notices and safety instructions.
Qualified personnel are those who, based on their training and experience, are capable of identifying risks and
avoiding potential hazards when working with these products/systems.
Proper use of Siemens products
Note the following:

WARNING
Siemens products may only be used for the applications described in the catalog and in the relevant technical
documentation. If products and components from other manufacturers are used, these must be recommended
or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and
maintenance are required to ensure that the products operate safely and without any problems. The permissible
ambient conditions must be complied with. The information in the relevant documentation must be observed.

Trademarks
All names identified by ® are registered trademarks of Siemens AG. The remaining trademarks in this publication
may be trademarks whose use by third parties for their own purposes could violate the rights of the owner.
Disclaimer of Liability
We have reviewed the contents of this publication to ensure consistency with the hardware and software
described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the
information in this publication is reviewed regularly and any necessary corrections are included in subsequent
editions.

Siemens AG A5E03727049-AJ Copyright © Siemens AG 2012 - 2018.


Division Digital Factory Ⓟ 02/2018 Subject to change All rights reserved
Postfach 48 48
90026 NÜRNBERG
GERMANY
Preface

Purpose of the documentation


This manual supplements the system manual ET 200SP distributed I/O system
(http://support.automation.siemens.com/WW/view/en/58649293). Functions affecting the
system in general are described there.
The information provided in this manual and in the system/function manuals supports you in
commissioning the system.

Conventions
Please also observe notes marked as follows:

Note
A note contains important information on the product described in the documentation, on the
handling of the product and on the section of the documentation to which particular attention
should be paid.

Changes compared to the previous version


In contrast to the previous version, the chapters "BaseUnits for motor starters" and
"Dimension drawings for motor starters" have been added to this manual.

Recycling and disposal


For ecologically sustainable recycling and disposal of your old device, contact a certificated
disposal service for electronic scrap and dispose of the device in accordance with the
regulations in your country.

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
Manual, 02/2018, A5E03727049-AJ 3
Preface

Security information
Siemens provides products and solutions with industrial security functions that support the
secure operation of plants, systems, machines and networks.
In order to protect plants, systems, machines and networks against cyber threats, it is
necessary to implement – and continuously maintain – a holistic, state-of-the-art industrial
security concept. Siemens' products and solutions constitute one element of such a concept.
Customers are responsible for preventing unauthorized access to their plants, systems,
machines and networks. Such systems, machines and components should only be
connected to an enterprise network or the internet if and to the extent such a connection is
necessary and only when appropriate security measures (e.g. firewalls and/or network
segmentation) are in place.
For additional information on industrial security measures that may be implemented, please
visit (https://www.siemens.com/industrialsecurity).
Siemens' products and solutions undergo continuous development to make them more
secure. Siemens strongly recommends that product updates are applied as soon as they are
available and that the latest product versions are used. Use of product versions that are no
longer supported, and failure to apply the latest updates may increase customers' exposure
to cyber threats.
To stay informed about product updates, subscribe to the Siemens Industrial Security RSS
Feed under (https://www.siemens.com/industrialsecurity).

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
4 Manual, 02/2018, A5E03727049-AJ
Table of contents

Preface ................................................................................................................................................... 3
1 Guide to the documentation .................................................................................................................... 8
2 New properties ...................................................................................................................................... 13
3 Product overview .................................................................................................................................. 14
4 BaseUnits for I/O modules .................................................................................................................... 21
4.1 Product description .................................................................................................................21
4.1.1 Introduction .............................................................................................................................21
4.2 BU type A0, light-colored version with AUX terminals ............................................................22
4.2.1 Product overview ....................................................................................................................22
4.2.2 Connecting up .........................................................................................................................23
4.2.3 Technical specifications ..........................................................................................................24
4.3 BU type A0, light-colored version without AUX terminals .......................................................26
4.3.1 Product overview ....................................................................................................................26
4.3.2 Connection ..............................................................................................................................27
4.3.3 Technical specifications ..........................................................................................................28
4.4 BU type A0, dark-colored version, with AUX terminals ..........................................................30
4.4.1 Product overview ....................................................................................................................30
4.4.2 Connection ..............................................................................................................................31
4.4.3 Technical specifications ..........................................................................................................32
4.5 BU type A0, dark-colored version, without AUX terminals .....................................................34
4.5.1 Product overview ....................................................................................................................34
4.5.2 Connection ..............................................................................................................................35
4.5.3 Technical specifications ..........................................................................................................36
4.6 BU type A1, light-colored version, with additional terminals ...................................................38
4.6.1 Product overview ....................................................................................................................38
4.6.2 Connection ..............................................................................................................................40
4.6.3 Technical specifications ..........................................................................................................41
4.7 BU type A1, light-colored version, without additional terminals ..............................................43
4.7.1 Product overview ....................................................................................................................43
4.7.2 Connection ..............................................................................................................................45
4.7.3 Technical specifications ..........................................................................................................46
4.8 BU type A1, dark-colored version, with additional terminals ..................................................48
4.8.1 Product overview ....................................................................................................................48
4.8.2 Connection ..............................................................................................................................49
4.8.3 Technical specifications ..........................................................................................................50
4.9 BU type A1, dark-colored version, without additional terminals .............................................52
4.9.1 Product overview ....................................................................................................................52
4.9.2 Connection ..............................................................................................................................53
4.9.3 Technical specifications ..........................................................................................................54

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
Manual, 02/2018, A5E03727049-AJ 5
Table of contents

4.10 BU type B0, dark-colored version, with AUX terminals, supply over P1, P2 busbar ............. 56
4.10.1 Product overview.................................................................................................................... 56
4.10.2 Connecting ............................................................................................................................. 57
4.10.3 Technical specifications ......................................................................................................... 58
4.11 BU type B1, dark-colored version, without AUX terminals, supply over supply terminals ..... 60
4.11.1 Product overview.................................................................................................................... 60
4.11.2 Connecting up ........................................................................................................................ 61
4.11.3 Technical specifications ......................................................................................................... 62
4.12 BU type C0, light-colored version, with AUX terminals, supply over supply terminals .......... 64
4.12.1 Product overview.................................................................................................................... 64
4.12.2 Connecting ............................................................................................................................. 66
4.12.3 Technical specifications ......................................................................................................... 67
4.13 BU type C1, dark-colored version, with AUX terminals, supply over P1, P2 busbar ............. 68
4.13.1 Product overview.................................................................................................................... 68
4.13.2 Connecting ............................................................................................................................. 69
4.13.3 Technical specifications ......................................................................................................... 70
4.14 BU type D0, dark-colored version, without AUX terminals, supply over supply
terminals ................................................................................................................................. 72
4.14.1 Product overview.................................................................................................................... 72
4.14.2 Connecting ............................................................................................................................. 73
4.14.3 Technical specifications ......................................................................................................... 74
4.15 BU type F0, dark-colored version, with AUX terminals, supply over supply terminals .......... 75
4.15.1 Product overview.................................................................................................................... 75
4.15.2 Connecting up ........................................................................................................................ 76
4.15.3 Technical specifications ......................................................................................................... 77
4.16 BU type U0, light-colored version without AUX terminals ...................................................... 79
4.16.1 Product overview.................................................................................................................... 79
4.16.2 Connection ............................................................................................................................. 80
4.16.3 Technical specifications ......................................................................................................... 81
4.17 BU type U0, dark-colored version, without AUX terminals .................................................... 83
4.17.1 Product overview.................................................................................................................... 83
4.17.2 Connection ............................................................................................................................. 84
4.17.3 Technical specifications ......................................................................................................... 85
5 BaseUnits for motor starters .................................................................................................................. 87
5.1 Introduction ............................................................................................................................ 87
5.2 BU30-MS1 - BaseUnit with 24 V DC and 500 V AC infeed ................................................... 88
5.2.1 Product overview.................................................................................................................... 88
5.2.2 Connection ............................................................................................................................. 89
5.2.3 Technical specifications ......................................................................................................... 91
5.3 BU30-MS2 - BaseUnit with 500 V AC infeed ......................................................................... 92
5.3.1 Product overview.................................................................................................................... 92
5.3.2 Connection ............................................................................................................................. 93
5.3.3 Technical specifications ......................................................................................................... 95

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
6 Manual, 02/2018, A5E03727049-AJ
Table of contents

5.4 BU30-MS3 - BaseUnit with 24 V DC infeed............................................................................96


5.4.1 Product overview ....................................................................................................................96
5.4.2 Connection ..............................................................................................................................97
5.4.3 Technical specifications ..........................................................................................................99
5.5 BU30-MS4 - BaseUnit without infeed ...................................................................................100
5.5.1 Product overview ..................................................................................................................100
5.5.2 Connection ............................................................................................................................101
5.5.3 Technical specifications ........................................................................................................103
5.6 BU30-MS5 BaseUnit with 500 V AC infeed and F-DI ...........................................................104
5.6.1 Product overview ..................................................................................................................104
5.6.2 Connection ............................................................................................................................106
5.6.3 Technical specifications ........................................................................................................108
5.7 BU30-MS6 BaseUnit without infeed and with F-DI ...............................................................109
5.7.1 Product overview ..................................................................................................................109
5.7.2 Connection ............................................................................................................................110
5.7.3 Technical specifications ........................................................................................................112
6 Potential distributor modules ............................................................................................................... 113
6.1 Introduction ...........................................................................................................................113
6.2 PotDis-BU type P1, light-colored version..............................................................................114
6.2.1 Short designation ..................................................................................................................114
6.2.2 Product overview ..................................................................................................................114
6.2.3 Connecting ............................................................................................................................115
6.2.4 Technical specifications ........................................................................................................116
6.3 PotDis-BU type P1, dark-colored version .............................................................................118
6.3.1 Product overview ..................................................................................................................118
6.3.2 Connecting ............................................................................................................................119
6.3.3 Technical specifications ........................................................................................................120
6.4 PotDis-BU type P2, light-colored version..............................................................................122
6.4.1 Short designation ..................................................................................................................122
6.4.2 Product overview ..................................................................................................................122
6.4.3 Connecting ............................................................................................................................123
6.4.4 Technical specifications ........................................................................................................124
6.5 PotDis-BU type P2, dark-colored version .............................................................................126
6.5.1 Short designation ..................................................................................................................126
6.5.2 Product overview ..................................................................................................................126
6.5.3 Connecting ............................................................................................................................127
6.5.4 Technical specifications ........................................................................................................128
6.6 PotDis-TB ..............................................................................................................................130
6.6.1 Product overview ..................................................................................................................130
6.6.2 Connecting ............................................................................................................................132
6.6.3 Technical specifications ........................................................................................................133
A Dimension drawings of I/O modules .................................................................................................... 141
B Dimension drawings of motor starters ................................................................................................. 144
7 Dimension drawings of the potential distributor modules ...................................................................... 145

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
Manual, 02/2018, A5E03727049-AJ 7
Guide to the documentation 1
The documentation for the SIMATIC ET 200SP distributed I/O system is arranged into three
areas.
This arrangement enables you to access the specific content you require.

Basic information
The system manual describes in detail the configuration, installation, wiring and
commissioning of the SIMATIC ET 200SP. distributed I/O system. The STEP 7 online help
supports you in the configuration and programming.

Device information
Product manuals contain a compact description of the module-specific information, such as
properties, wiring diagrams, characteristics and technical specifications.

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
8 Manual, 02/2018, A5E03727049-AJ
Guide to the documentation

General information
The function manuals contain detailed descriptions on general topics regarding the SIMATIC
ET 200SP distributed I/O system, e.g. diagnostics, communication, Web server, motion
control and OPC UA.
You can download the documentation free of charge from the Internet
(https://support.industry.siemens.com/cs/ww/de/view/58649293).
Changes and supplements to the manuals are documented in a Product Information.
You can download the product information free of charge from the Internet
(https://support.industry.siemens.com/cs/ww/de/view/109742709).

Manual Collection ET 200SP


The Manual Collection contains the complete documentation on the SIMATIC ET 200SP
distributed I/O system gathered together in one file.
You can find the Manual Collection on the Internet
(http://support.automation.siemens.com/WW/view/en/84133942).

"mySupport"
With "mySupport", your personal workspace, you make the most of your Industry Online
Support.
In "mySupport" you can store filters, favorites and tags, request CAx data and put together
your personal library in the Documentation area. Furthermore, your data is automatically
filled into support requests and you always have an overview of your current requests.
You need to register once to use the full functionality of "mySupport".
You can find "mySupport" in the Internet (https://support.industry.siemens.com/My/ww/de/).

"mySupport" - Documentation
In the Documentation area of "mySupport", you have the possibility to combine complete
manuals or parts of them to make your own manual.
You can export the manual in PDF format or in an editable format.
You can find "mySupport" - Documentation in the Internet
(http://support.industry.siemens.com/My/ww/en/documentation).

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
Manual, 02/2018, A5E03727049-AJ 9
Guide to the documentation

"mySupport" - CAx Data


In the CAx Data area of "mySupport", you can have access the latest product data for your
CAx or CAe system.
You configure your own download package with a few clicks.
In doing so you can select:
● Product images, 2D dimension drawings, 3D models, internal circuit diagrams, EPLAN
macro files
● Manuals, characteristics, operating manuals, certificates
● Product master data
You can find "mySupport" - CAx Data in the Internet
(http://support.industry.siemens.com/my/ww/en/CAxOnline).

Application examples
The application examples support you with various tools and examples for solving your
automation tasks. Solutions are shown in interplay with multiple components in the system -
separated from the focus in individual products.
You can find the application examples on the Internet
(http://support.industry.siemens.com/cs/ww/en/ps/ae).

TIA Selection Tool


With the TIA Selection Tool, you can select, configure and order devices for Totally
Integrated Automation (TIA).
This tool is the successor of the SIMATIC Selection Tool and combines the known
configurators for automation technology into one tool.
With the TIA Selection Tool, you can generate a complete order list from your product
selection or product configuration.
You can find the TIA Selection Tool on the Internet
(http://w3.siemens.com/mcms/topics/en/simatic/tia-selection-tool).

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
10 Manual, 02/2018, A5E03727049-AJ
Guide to the documentation

SIMATIC Automation Tool


You can use the SIMATIC Automation Tool to run commissioning and maintenance activities
simultaneously on various SIMATIC S7 stations as a bulk operation independently of the TIA
Portal.
The SIMATIC Automation Tool provides a multitude of functions:
● Scanning of a PROFINET/Ethernet network and identification of all connected CPUs
● Address assignment (IP, subnet, gateway) and station name (PROFINET device) to a
CPU
● Transfer of the data and the programming device/PC time converted to UTC time to the
module
● Program download to CPU
● Operating mode switchover RUN/STOP
● Localization of the CPU by means of LED flashing
● Reading out CPU error information
● Reading the CPU diagnostic buffer
● Reset to factory settings
● Updating the firmware of the CPU and connected modules
You can find the SIMATIC Automation Tool on the Internet
(https://support.industry.siemens.com/cs/ww/de/view/109751152).

PRONETA
With SIEMENS PRONETA (PROFINET network analysis), you analyze the plant network
during commissioning. PRONETA features two core functions:
● The topology overview independently scans PROFINET and all connected components.
● The IO check is a fast test of the wiring and the module configuration of a system.
You can find SIEMENS PRONETA on the Internet
(https://support.industry.siemens.com/cs/ww/de/view/67460624).

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
Manual, 02/2018, A5E03727049-AJ 11
Guide to the documentation

SINETPLAN
SINETPLAN, the Siemens Network Planner, supports you in planning automation systems
and networks based on PROFINET. The tool facilitates professional and predictive
dimensioning of your PROFINET installation as early as in the planning stage. In addition,
SINETPLAN supports you during network optimization and helps you to exploit network
resources optimally and to plan reserves. This helps to prevent problems in commissioning
or failures during productive operation even in advance of a planned operation. This
increases the availability of the production plant and helps improve operational safety.
The advantages at a glance
● Network optimization thanks to port-specific calculation of the network load
● Increased production availability thanks to online scan and verification of existing systems
● Transparency before commissioning through importing and simulation of existing STEP 7
projects
● Efficiency through securing existing investments in the long term and optimal exploitation
of resources
You can find SINETPLAN on the Internet
(https://support.industry.siemens.com/cs/ww/de/view/109485570).

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
12 Manual, 02/2018, A5E03727049-AJ
New properties 2
What's new in the BaseUnits manual, edition 02/2018, compared to edition 12/2016?

What's new? What are the customer benefits? Where can I find infor-
mation?
New Potential distributor A system-integrated potential distribu- Section Potential distrib-
contents modules tion can be implemented via the utor modules (Page 113)
PotDis modules.
One application is, for example, the
design of digital input modules with 16
channels and three-wire connection.
You use the potential distributor mod-
ules to reserve the unused signal
cables of antivalent sensors.
Another application is the supply of
potentials for supply of external com-
ponents.
BaseUnit type U0 Light-colored version: Section
Can be used for all I/O BU20-P16+A0+2D BU20-P16+A0+2D
modules whose article Per slot, up to 16 process terminals (Page 79)
number ends in U0 can be supplied to the module with
max. 230 V/5 A per terminal.
• 2 supply terminals on integrated
self-assembling voltage buses
P1/P2, max. 230 V AC/10 A
• Separation of voltage buses P1/P2
and AUX from the adjacent mod-
ule on the left
Dark-colored version: BU20- Section
P16+A0+2B BU20-P16+A0+2B
Per slot, up to 16 process terminals (Page 83)
can be supplied to the module with
max. 230 V/5 A per terminal.
• 2 terminals for external sup-
ply/forwarding from integrated self-
assembling voltage buses P1/P2
• Bridging voltage buses P1/P2 and
AUX to the adjacent module on
the left

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
Manual, 02/2018, A5E03727049-AJ 13
Product overview 3
General properties of the BaseUnits
The ET 200SP distributed I/O system includes various BaseUnits. You use the BaseUnit to
specify the following, for example:
● Process connection
● Plug-in I/O module/motor starter
● Infeed of supply voltage specified
You can recognize the properties of the BaseUnits from their short description:

Table 3- 1 Properties of the BaseUnits

Short description BU15-P16+A10+2D/T BaseUnit properties


(example)
Name/module width BU 15 BaseUnit with width of 15 mm
20 BaseUnit with width of 20 mm
30 BaseUnit with width of 30 mm
Process connection P 4 • Connection method: Push-in terminal
• Number of terminals to the I/O module: 4
8 • Connection method: Push-in terminal
• Number of terminals to the I/O module: 8
16 • Connection method: Push-in terminal
• Number of terminals to the I/O module: 16
Connection to the AUX A 0 No connection to the AUX busbar
busbar 10 n = number of AUX terminals, e.g. 10

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
14 Manual, 02/2018, A5E03727049-AJ
Product overview

Short description BU15-P16+A10+2D/T BaseUnit properties


(example)
Self-assembling voltage 2 2 push-in terminals for supplying or tapping the supply
buses voltage via the self-assembling voltage buses P1, P2
(see D, B)
12 • 2 push-in terminals for supplying or tapping the
supply voltage via the self-assembling voltage
buses P1, P2 (see D, B)
• 2×5 push-in additional terminals (1 B to 5 B, 1 C to
5 C). For connecting further potential up to a max-
imum supply current of 24 V DC/10 A
0 No terminals with access to the self-assembling volt-
age buses P1, P2
B • Looping through the potential group
• Tapping of the supply voltage for external compo-
nents or looping through with a maximum total cur-
rent of 10 A per potential group
D • Opening a new potential group
• Feeding in of supply voltage up to a maximum
supply current of 10 A
Additional functions T Integrated temperature sensor to compensate the
reference junction temperature for thermocouples

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
Manual, 02/2018, A5E03727049-AJ 15
Product overview

Properties of the BaseUnits for motor starters


The following table lists the properties of the individual BaseUnits for motor starters:

BaseUnit Properties
BU30-MS1 • Push-in terminals for opening a new potential group (24 V DC).
• Feeding in of supply voltage up to a maximum supply current of 7 A
DC.
• Opening a new supply voltage potential group (500 V AC)
• Feeding in of supply voltage up to a maximum supply current of
32 A AC.
BU30-MS2 • Further conduction of the potential group (24 V DC)
• Push-in terminals for opening a new supply voltage potential group
(500 V AC)
• Infeed of supply voltage up to a maximum supply current up to 32 A
AC.
BU30-MS3 • Push-in terminals for opening a new potential group (24 V DC).
• Infeed of the supply voltage L+ up to an infeed current of 7 A DC
• Further conduction of the supply voltage potential group (500 V AC)
BU30-MS4 • Further conduction of the supply voltage potential group (500 V AC)
• Further conduction of the potential group (24 V DC)
BU30-MS5 • Further conduction of the potential group (24 V DC)
• Push-in terminals for opening a new supply voltage potential group
(500 V AC)
• Infeed of supply voltage up to a maximum supply current of 32 A AC
• A fail-safe digital input
BU30-MS6 • Further conduction of the potential group (24 V DC)
• Further conduction of the supply voltage potential group (500 V AC)
• Push-In terminals
• A fail-safe digital input

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
16 Manual, 02/2018, A5E03727049-AJ
Product overview

Properties of the potential distributor modules


The following table shows the properties of the individual potential distributor modules:

Table 3- 2 PotDis-BaseUnits properties

Short description PotDis-BU-P1/D-R PotDis-BaseUnit properties


(example)
Designation PotDis-BU PotDis-BaseUnit
Process connection P1 Terminals for supplying or tapping the supply voltage
(24 V DC / 10 A) with connection to the voltage bus P1 (see D, B)
P2 Terminals for supplying or tapping the supply voltage
with connection to the voltage bus P2 (see D, B)
Self-assembling voltage D • Opening a new PotDis potential group
buses
• Feeding in of supply voltage up to a maximum
supply current up to 10 A
• Tapping the supply voltage for external compo-
nents or looping with a maximum total current of
10 A per potential group
B • Further conduction of the potential group
• Tapping the supply voltage for external compo-
nents or looping with a maximum total current of
10 A per potential group
Color coding of the R Connection to the internal voltage bus P1
spring releases Red spring release
B Connection to the internal voltage bus P2
Blue spring release

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
Manual, 02/2018, A5E03727049-AJ 17
Product overview

Properties of the terminal blocks PotDis-TB


The following table shows the properties of the individual terminal blocks:

Table 3- 3 Properties of the PotDis-Terminalblocks

Short description PotDis-TB-P1-R (example) PotDis-Terminalblock properties


Designation PotDis-TB PotDis terminal block
Process connection P1 • Connection to the voltage bus P1
(24 V DC / 10 A) • Terminals for picking off the rated supply voltage
24 V DC with max. 10 A of the same voltage level
P2 • Connection to the voltage bus P2
• Terminals for picking off the rated supply voltage
24 V DC with max. 10 A of the same voltage level
n.c. • No connection to the P1, P2 or AUX bus
• Terminals can be used freely up to 230 V AC with
max. 10 A
BR • No connection to the P1, P2 or AUX bus
• Terminals for protective conductor connection or
voltage bus (internal connected) freely usable up to
230 V AC with max. 10 A
Color coding of the R Red spring release
spring releases
B Blue spring release
W White spring release
G Gray spring release

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
18 Manual, 02/2018, A5E03727049-AJ
Product overview

Selecting, installing and connecting BaseUnits


You can find additional information in the system manual ET 200SP Distributed I/O System
(http://support.automation.siemens.com/WW/view/en/58649293).

WARNING
Personal injury or damage to equipment is possible.
Connecting a rated supply voltage to the BaseUnit higher than the one given in the
technical specifications may lead to dangerous situations in your plant or cause defects in
ET 200SP components.
Therefore, only connect the rated supply voltage given in the technical specifications to the
BaseUnit.
The connected rated supply voltage must correspond to the rated supply voltage of the I/O
modules in the potential group.
When mains voltage is connected to the BaseUnit, ensure that all other supply voltages on
this BaseUnit use the same phase as the mains.

The Totally Integrated Automation Selection Tool (TIA Selection Tool)


(http://w3.siemens.com/mcms/topics/de/simatic/tia-selection-tool) supports you in selecting,
configuring and ordering the ET 200SP modules. The free TIA Selection Tool is available on
the Internet (http://support.automation.siemens.com/WW/view/en/58649293).

WARNING
Hazardous Voltage (when using ET 200SP motor starters)
Can Cause Death, Serious Injury, or Property Damage.
Proper use of hardware products
This equipment is only allowed to be used for the applications described in the catalog and
in the technical description, and only in conjunction with non-Siemens equipment and
components recommended by Siemens.
Correct transport, storage, installation and assembly, as well as careful operation and
maintenance, are required to ensure that the product operates safely and without faults.
EU note: Start-up/commissioning is absolutely prohibited until it has been ensured that the
machine in which the component described here is to be installed fulfills the
regulations/specifications of Machinery Directive 2006/42/EC.

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
Manual, 02/2018, A5E03727049-AJ 19
Product overview

WARNING
Hazardous Voltage (when using ET 200SP motor starters)
Can Cause Death, Serious Injury, or Property Damage.
Please take note of our latest information.
Systems with safety-related characteristics are subject to special operational safety
requirements on the part of the operator. The supplier is also obliged to comply with special
product monitoring measures. For this reason, we publish a special newsletter containing
information on product developments and features that are (or could be) relevant to
operation of safety-related systems. You need to subscribe to the corresponding newsletter
to ensure that you always remain up-to-date and are able to make any necessary changes
to your plant regarding operational safety should the need arise.
Siemens Newsletter (http://www.industry.siemens.com/newsletter)
Sign on to the following newsletter under "Products & Solutions":
• Control Components and System Engineering News
• Safety Integrated Newsletter

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
20 Manual, 02/2018, A5E03727049-AJ
BaseUnits for I/O modules 4
4.1 Product description

4.1.1 Introduction

Properties of the BaseUnits


The ET 200SP distributed I/O system offers you a rugged and service-friendly design with
permanent wiring over the BaseUnits (BU).
The BaseUnits provide the electrical and mechanical connection of the ET 200SP modules.
A wide range of BaseUnits is available to suit individual requirements.
You can place BaseUnits at any location with the ET 200SP distributed I/O system. Thanks
to the push-in connection system, you can wire the terminals without tools.
Note the following restrictions:
● The potential group based on SELV/PELV supply or the PotDis version is light-colored.
● The infeed of protective conductor via BU is not permitted.
You can find additional information on using the BaseUnit in the ET 200SP System Manual
(https://support.industry.siemens.com/cs/ww/en/view/58649293).

Note
All BaseUnits placed in a load group must match the infeed potential of the corresponding
light-colored BaseUnits.

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
Manual, 02/2018, A5E03727049-AJ 21
BaseUnits for I/O modules
4.2 BU type A0, light-colored version with AUX terminals

4.2 BU type A0, light-colored version with AUX terminals

Short designation
Short designation: BU15-P16+A10+2D

4.2.1 Product overview

Delivery options (packing unit VPE)


6ES7193-6BP20-0DA0 (VPE: 1 unit)
6ES7193-6BP20-2DA0 (VPE: 10 units)

View

Figure 4-1 BU type A0, light-colored version with AUX terminals

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
22 Manual, 02/2018, A5E03727049-AJ
BaseUnits for I/O modules
4.2 BU type A0, light-colored version with AUX terminals

Properties
● BaseUnit suitable for all I/O modules of the BaseUnit type "A0/A1". Can be recognized by
the laser inscription on the front and/or the last two digits of the article number.
– Supply voltage (L+ terminal, ground): Max. 24 V DC/10 A
– Current-carrying capacity per process terminal (terminal 1 to 16): Max. 2 A
● The BaseUnit opens up a new potential group. The self-assembling voltage buses P1 and
P2, and the AUX busbar are interrupted to the left-hand neighboring module (BaseUnit,
interface module).
● Access to the AUX busbar via terminals
● 16 terminals to the process (assignment through the I/O module)
● 10 AUX terminals for connecting a protective conductor or potential. The AUX busbar is
not connected to the I/O module. Max. 24 V DC/10 A
● Connection system in the form of push-in terminals Connection cross-sections are
available in the ET 200SP System Manual
(https://support.industry.siemens.com/cs/ww/de/view/58649293).

Maximum configuration per potential group


The number of I/O modules that can be used per potential group depends on the following
factors:
1. Total power requirement of all I/O modules operated on this potential group
2. Total power requirement of all loads connected externally to this potential group
The total current calculated according to item 1. and item 2. must not exceed 10 A.

4.2.2 Connecting up

Pin assignment

Pin assignment for BaseUnit BU type A0, light-colored version with AUX terminals
Terminal Descriptions
1 to 16 Assignment is determined by the I/O module. You can find additional
information in the I/O Module
(http://support.automation.siemens.com/WW/view/en/55679691/133300)
manual.
1 A, 2 A, 3 A, 4 A, 5 A, Protective conductor connection or voltage bus freely usable up to
6 A, 7 A, 8 A, 9 A, 10 A 24 V DC with max. 10 A
L+/ M L+: Rated supply voltage 24 V DC with max. 10 A
M: Ground

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
Manual, 02/2018, A5E03727049-AJ 23
BaseUnits for I/O modules
4.2 BU type A0, light-colored version with AUX terminals

Block diagram

① Backplane bus
② I/O module
③ Terminals with connection to the I/O module
④ System-integrated, self-assembling voltage buses P1, P2 with connection to the supply termi-
nals, interrupted to the adjacent module on the left (forms a new potential group)
⑤ System-integrated, self-assembling AUX voltage bus with connection to the 10 AUX terminals,
interrupted to the adjacent module on the left (forms a new potential group)

Figure 4-2 Block diagram of the BU type A0, light-colored version with AUX terminals

4.2.3 Technical specifications

Technical specifications of the BU-Typ A0, Variante hell mit AUX-Klemmen

Article number 6ES7193-6BP20-2DA0


General information
Product type designation Type A0
Supply voltage
Rated value (DC) 24 V
external protection for power supply lines Yes; 24 V DC/10 A miniature circuit breaker with
type B or C tripping characteristic
Current carrying capacity
For P1 and P2 bus, max. 10 A
For AUX bus, max. 10 A
For process terminals, max. 2A

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
24 Manual, 02/2018, A5E03727049-AJ
BaseUnits for I/O modules
4.2 BU type A0, light-colored version with AUX terminals

Article number 6ES7193-6BP20-2DA0


Hardware configuration
Formation of potential groups
• New potential group Yes

• Potential group continued from the left No

Potential separation
between the potential groups Yes
Isolation
Isolation tested with 707 V DC (type test)
Accessories
Color coding labels
• for process terminals CC00 to CC09

• for AUX terminals CC71 to CC73

• for add-on terminals does not exist

Connection method
Terminals
• Terminal type Push-in terminal

• Conductor cross-section, min. 0.14 mm²; AWG 26

• Conductor cross-section, max. 2.5 mm²; AWG 14

• Number of process terminals to I/O module 16

• Number of terminals to AUX bus 0

• Number of add-on terminals 0

• Number of terminals with connection to P1 2


and P2 bus
Dimensions
Width 15 mm
Height 141 mm
Depth 35 mm
Weights
Weight, approx. 50 g

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
Manual, 02/2018, A5E03727049-AJ 25
BaseUnits for I/O modules
4.3 BU type A0, light-colored version without AUX terminals

4.3 BU type A0, light-colored version without AUX terminals

Short designation
Short designation: BU15-P16+A0+2D

4.3.1 Product overview

Delivery options (packing unit VPE)


6ES7193-6BP00-0DA0 (VPE: 1 unit)
6ES7193-6BP00-2DA0 (VPE: 10 units)

View

Figure 4-3 BU type A0, light-colored version, without AUX terminals

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
26 Manual, 02/2018, A5E03727049-AJ
BaseUnits for I/O modules
4.3 BU type A0, light-colored version without AUX terminals

Properties
● BaseUnit suitable for all I/O modules of the BaseUnit type "A0/A1". Can be recognized by
the laser inscription on the front and/or the last two digits of the article number.
– Supply voltage (L+ terminal, ground): Max. 24 V DC/10 A
– Current-carrying capacity per process terminal (terminal 1 to 16): Max. 2 A
● The BaseUnit opens up a new potential group. The self-assembling voltage buses P1 and
P2, and the AUX busbar are interrupted to the left-hand neighboring module (BaseUnit,
interface module).
● No access to the AUX busbar via terminals
● 16 terminals to the process (assignment through the I/O module)
● Connection system in the form of push-in terminals Connection cross-sections are
available in the ET 200SP System Manual
(https://support.industry.siemens.com/cs/ww/de/view/58649293).

Maximum configuration per potential group


The number of I/O modules that can be used per potential group depends on the following
factors:
1. Total power requirement of all I/O modules operated on this potential group
2. Total power requirement of all loads connected externally to this potential group
The total current calculated according to item 1. and item 2. must not exceed 10 A.

4.3.2 Connection

Pin assignment

Pin assignment for BaseUnit BU type A0, light-colored version, without AUX terminals
Terminal Descriptions
1 to 16 Assignment is determined by the I/O module. You can find additional infor-
mation in the I/O Module
(http://support.automation.siemens.com/WW/view/en/55679691/133300)
manual.
(AUX) No access to the AUX busbar via terminals
L+ / M L+: Rated supply voltage 24 V DC with max. 10 A
M: Ground

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
Manual, 02/2018, A5E03727049-AJ 27
BaseUnits for I/O modules
4.3 BU type A0, light-colored version without AUX terminals

Block diagram

① Backplane bus
② I/O module
③ Terminals with connection to the I/O module
④ System-integrated, self-assembling voltage buses P1, P2 with connection to the supply termi-
nals, interrupted to the adjacent module on the left (forms a new potential group)
⑤ System-integrated, self-assembling AUX voltage bus without connection to the AUX terminals,
interrupted to the adjacent module on the left (forms a new potential group)

Figure 4-4 Block diagram of the BU type A0, light-colored version, without AUX terminals

4.3.3 Technical specifications

Technical specifications of the BaseUnit BU type A0, light-colored version, without AUX
terminals

Article number 6ES7193-6BP20-2DA0


General information
Product type designation Type A0
Supply voltage
Rated value (DC) 24 V
external protection for power supply lines Yes; 24 V DC/10 A miniature circuit breaker with
type B or C tripping characteristic
Current carrying capacity
For P1 and P2 bus, max. 10 A
For AUX bus, max. 10 A
For process terminals, max. 2A

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
28 Manual, 02/2018, A5E03727049-AJ
BaseUnits for I/O modules
4.3 BU type A0, light-colored version without AUX terminals

Article number 6ES7193-6BP20-2DA0


Hardware configuration
Formation of potential groups
• New potential group Yes

• Potential group continued from the left No

Potential separation
between the potential groups Yes
Isolation
Isolation tested with 707 V DC (type test)
Accessories
Color coding labels
• for process terminals CC00 to CC09

• for AUX terminals CC71 to CC73

• for add-on terminals does not exist

Connection method
Terminals
• Terminal type Push-in terminal

• Conductor cross-section, min. 0.14 mm²; AWG 26

• Conductor cross-section, max. 2.5 mm²; AWG 14

• Number of process terminals to I/O module 16

• Number of terminals to AUX bus 0

• Number of add-on terminals 0

• Number of terminals with connection to P1 2


and P2 bus
Dimensions
Width 15 mm
Height 141 mm
Depth 35 mm
Weights
Weight, approx. 50 g

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
Manual, 02/2018, A5E03727049-AJ 29
BaseUnits for I/O modules
4.4 BU type A0, dark-colored version, with AUX terminals

4.4 BU type A0, dark-colored version, with AUX terminals

Short designation
Short designation: BU15-P16+A10+2B

4.4.1 Product overview

Delivery options (packing unit VPE)


6ES7193-6BP20-0BA0 (VPE: 1 unit)
6ES7193-6BP20-2BA0 (VPE: 10 units)

View

Figure 4-5 BU type A0, dark-colored version, with AUX terminals

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
30 Manual, 02/2018, A5E03727049-AJ
BaseUnits for I/O modules
4.4 BU type A0, dark-colored version, with AUX terminals

Properties
● BaseUnit suitable for all I/O modules of the BaseUnit type "A0/A1". Can be recognized by
the laser inscription on the front and/or the last two digits of the article number.
– Current-carrying capacity per process terminal (terminal 1 to 16): Max. 2 A
● The BaseUnit conducts the potential group further. The self-assembling voltage buses P1
and P2, and the AUX busbar are connected to the left-hand neighboring module
(BaseUnit).
● Access to the AUX busbar via terminals
● 16 terminals to the process (assignment through the I/O module)
● 10 AUX terminals for connecting a protective conductor or potential. The AUX busbar is
not connected to the I/O module. Max. 24 V DC/10 A
● Connection system in the form of push-in terminals Connection cross-sections are
available in the ET 200SP System Manual
(https://support.industry.siemens.com/cs/ww/de/view/58649293).

4.4.2 Connection

Pin assignment

Pin assignment for BU type A0, dark-colored version, with AUX terminals
Terminal Descriptions
1 to 16 Assignment is determined by the I/O module. You can find additional
information in the I/O Module
(http://support.automation.siemens.com/WW/view/en/55679691/133300)
manual.
1 A, 2 A, 3 A, 4 A, 5 A, Protective conductor connection or voltage bus freely usable up to
6 A, 7 A, 8 A, 9 A, 10 A, 24 V DC with max. 10 A
AUX
L+ / M L+: Rated supply voltage 24 V DC with max. 10 A
M: Ground

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
Manual, 02/2018, A5E03727049-AJ 31
BaseUnits for I/O modules
4.4 BU type A0, dark-colored version, with AUX terminals

Block diagram

① Backplane bus
② I/O module
③ Terminals with connection to the I/O module
④ System-integrated, self-assembling voltage buses P1, P2 with connection to the supply termi-
nals, connected to the adjacent module on the left
⑤ System-integrated, self-assembling AUX voltage bus with connection to the 10 AUX terminals,
connected to the adjacent module on the left

Figure 4-6 Block diagram of the BU type A0, dark-colored version, with AUX terminals

4.4.3 Technical specifications

Technical specifications of the BU type A0, dark-colored version, with AUX terminals

Article number 6ES7193-6BP20-0BA0


General information
Product type designation Type A0
Supply voltage
Rated value (DC) 24 V
external protection for power supply lines Yes; 24 V DC/10 A miniature circuit breaker with
type B or C tripping characteristic
Current carrying capacity
For P1 and P2 bus, max. 10 A
For AUX bus, max. 10 A
For process terminals, max. 2A

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
32 Manual, 02/2018, A5E03727049-AJ
BaseUnits for I/O modules
4.4 BU type A0, dark-colored version, with AUX terminals

Article number 6ES7193-6BP20-0BA0


Hardware configuration
Formation of potential groups
• New potential group No

• Potential group continued from the left Yes

Isolation
Isolation tested with 707 V DC (type test)
Accessories
Color coding labels
• for process terminals CC00 to CC09

• for AUX terminals CC71 to CC73

• for add-on terminals does not exist

Connection method
Terminals
• Terminal type Push-in terminal

• Conductor cross-section, min. 0.14 mm²; AWG 26

• Conductor cross-section, max. 2.5 mm²; AWG 14

• Number of process terminals to I/O module 16

• Number of terminals to AUX bus 0

• Number of add-on terminals 0

• Number of terminals with connection to P1 2


and P2 bus
Dimensions
Width 15 mm
Height 141 mm
Depth 35 mm
Weights
Weight, approx. 50 g

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
Manual, 02/2018, A5E03727049-AJ 33
BaseUnits for I/O modules
4.5 BU type A0, dark-colored version, without AUX terminals

4.5 BU type A0, dark-colored version, without AUX terminals

Short designation
Short designation: BU15-P16+A0+2B

4.5.1 Product overview

Delivery options (packing unit VPE)


6ES7193-6BP00-0BA0 (VPE: 1 unit)
6ES7193-6BP00-2BA0 (VPE: 10 units)

View

Figure 4-7 BU type A0, dark-colored version, without AUX terminals

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
34 Manual, 02/2018, A5E03727049-AJ
BaseUnits for I/O modules
4.5 BU type A0, dark-colored version, without AUX terminals

Properties
● BaseUnit suitable for all I/O modules of the BaseUnit type "A0/A1". Can be recognized by
the laser inscription on the front and/or the last two digits of the article number.
– Current-carrying capacity per process terminal (terminal 1 to 16): Max. 2 A
● The BaseUnit conducts the potential group further. The self-assembling voltage buses P1
and P2, and the AUX busbar are connected to the left-hand neighboring module
(BaseUnit).
● No access to the AUX busbar via terminals
● 16 terminals to the process (assignment through the I/O module)
● Connection system in the form of push-in terminals Connection cross-sections are
available in the ET 200SP System Manual
(https://support.industry.siemens.com/cs/ww/de/view/58649293).

4.5.2 Connection

Pin assignment

Pin assignment for BU type A0, dark-colored version, without AUX terminals
Terminal Descriptions
1 to 16 Assignment is determined by the I/O module. You can find additional infor-
mation in the I/O Module
(http://support.automation.siemens.com/WW/view/en/55679691/133300)
manual.
(AUX) No access to the AUX busbar via terminals
L+ / M L+: Rated supply voltage 24 V DC with max. 10 A
M: Ground

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
Manual, 02/2018, A5E03727049-AJ 35
BaseUnits for I/O modules
4.5 BU type A0, dark-colored version, without AUX terminals

Block diagram

① Backplane bus
② I/O module
③ Terminals with connection to the I/O module
④ System-integrated, self-assembling voltage buses P1, P2 with connection to the supply termi-
nals, connected to the adjacent module on the left
⑤ System-integrated, self-assembling AUX voltage bus without connection to the AUX terminals,
connected to the adjacent module on the left

Figure 4-8 Block diagram of the BU type A0, dark-colored version, without AUX terminals

4.5.3 Technical specifications

Technical specifications of the BU type A0, dark-colored version, without AUX terminals

Article number 6ES7193-6BP00-0BA0


General information
Product type designation BU type A0, dark version, without AUX terminals,
PU 1
Supply voltage
Rated value (DC) 24 V
external protection for power supply lines Yes; 24 V DC/10 A miniature circuit breaker with
type B or C tripping characteristic
Current carrying capacity
For P1 and P2 bus, max. 10 A
For process terminals, max. 2A
Hardware configuration
Formation of potential groups
• New potential group No

• Potential group continued from the left Yes

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
36 Manual, 02/2018, A5E03727049-AJ
BaseUnits for I/O modules
4.5 BU type A0, dark-colored version, without AUX terminals

Article number 6ES7193-6BP00-0BA0


Isolation
Isolation tested with 707 V DC (type test)
Accessories
Color coding labels
• for process terminals CC00 to CC09

• for AUX terminals does not exist

• for add-on terminals does not exist

Connection method
Terminals
• Terminal type Push-in terminal

• Conductor cross-section, min. 0.14 mm²; AWG 26

• Conductor cross-section, max. 2.5 mm²; AWG 14

• Number of process terminals to I/O module 16

• Number of terminals to AUX bus 0

• Number of add-on terminals 0

• Number of terminals with connection to P1 2


and P2 bus
Dimensions
Width 15 mm
Height 117 mm
Depth 35 mm
Weights
Weight, approx. 40 g

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
Manual, 02/2018, A5E03727049-AJ 37
BaseUnits for I/O modules
4.6 BU type A1, light-colored version, with additional terminals

4.6 BU type A1, light-colored version, with additional terminals

Short designation
Short designation: BU15-P16+A0+12D/T

4.6.1 Product overview

Delivery options (packing unit VPE)


6ES7193-6BP40-0DA1 (VPE: 1 unit)

View

Figure 4-9 BU type A1, light-colored version, with additional terminals

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
38 Manual, 02/2018, A5E03727049-AJ
BaseUnits for I/O modules
4.6 BU type A1, light-colored version, with additional terminals

Properties
● BaseUnit for all I/O modules of BaseUnit type "A1". Can be recognized by the laser
inscription on the front and/or the last two digits of the article number.

Note
Using another I/O module can trigger an internal, non-exchangeable fuse and you must
exchange the terminal box.

– Supply voltage (L+ terminal, ground): Max. 24 V DC/10 A


– Current-carrying capacity per process terminal (terminal 1 to 16): Max. 2 A
● The BaseUnit opens up a new potential group. The self-assembling voltage buses P1 and
P2, and the AUX busbar are interrupted to the left-hand neighboring module (BaseUnit,
interface module).
● No access to the AUX busbar via terminals
● 16 terminals to the process (assignment through the I/O module)
● 2x5 additional terminals for supplying a supply voltage up to 24 V DC/ 10 A. The
additional terminals are not connected to the I/O module.
● Recording of the terminal temperature for internal temperature compensation at
connected thermocouples
● Connection system in the form of push-in terminals Connection cross-sections are
available in the ET 200SP System Manual
(https://support.industry.siemens.com/cs/ww/de/view/58649293).

Maximum configuration per potential group


The number of I/O modules that can be used per potential group depends on the following
factors:
1. Total power requirement of all I/O modules operated on this potential group
2. Total power requirement of all loads connected externally to this potential group
The total current calculated according to item 1. and item 2. must not exceed 10 A.

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
Manual, 02/2018, A5E03727049-AJ 39
BaseUnits for I/O modules
4.6 BU type A1, light-colored version, with additional terminals

4.6.2 Connection

Pin assignment

Pin assignment for BU type A1, light-colored version, with additional terminals
Terminal Descriptions
1 to 16 Assignment is determined by the I/O module. You can find additional infor-
mation in the I/O Module
(http://support.automation.siemens.com/WW/view/en/55679691/133300)
manual.
1 B, 2 B, 3 B, 4 B, 2 x 5 add-on terminals for the infeed of a supply voltage up to 24 V DC with
5B/ max. 10 A
1 C, 2 C, 3 C, 4 C,
5C
(AUX) No access to the AUX busbar via terminals
L+ / M L+: Rated supply voltage 24 V DC with max. 10 A
M: Ground

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
40 Manual, 02/2018, A5E03727049-AJ
BaseUnits for I/O modules
4.6 BU type A1, light-colored version, with additional terminals

Block diagram

① Backplane bus
② I/O module
③ Internal reference junction for temperature compensation
④ Terminals with connection to the I/O module
⑤ Additional terminals for feeding an additional supply voltage
⑥ System-integrated, self-assembling voltage buses P1, P2 with connection to the supply termi-
nals, interrupted to the adjacent module on the left (forms a new potential group)
⑦ System-integrated, self-assembling AUX voltage bus without connection to the AUX terminals,
interrupted to the adjacent module on the left (forms a new potential group)

Figure 4-10 Block diagram of the BU type A1, light-colored version, with additional terminals

4.6.3 Technical specifications

Technical specifications of the BU type A1, light-colored version, with additional terminals

Article number 6ES7193-6BP40-0DA1


General information
Product type designation Type A1
Supply voltage
Rated value (DC) 24 V
external protection for power supply lines Yes; 24 V DC/10 A miniature circuit breaker with
type B or C tripping characteristic

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
Manual, 02/2018, A5E03727049-AJ 41
BaseUnits for I/O modules
4.6 BU type A1, light-colored version, with additional terminals

Article number 6ES7193-6BP40-0DA1


Current carrying capacity
For P1 and P2 bus, max. 10 A
For process terminals, max. 2A
Hardware configuration
Additional terminals Yes
Temperature sensor Yes
Formation of potential groups
• New potential group Yes

• Potential group continued from the left No

Potential separation
between the potential groups Yes
Isolation
Isolation tested with 707 V DC (type test)
Accessories
Color coding labels
• for process terminals CC00 to CC09

• for AUX terminals does not exist

• for add-on terminals CC74

Connection method
Terminals
• Terminal type Push-in terminal

• Conductor cross-section, min. 0.14 mm²; AWG 26

• Conductor cross-section, max. 2.5 mm²; AWG 14

• Number of process terminals to I/O module 16

• Number of terminals to AUX bus 0

• Number of add-on terminals 0

• Number of terminals with connection to P1 2


and P2 bus
Dimensions
Width 15 mm
Height 141 mm
Depth 35 mm
Weights
Weight, approx. 50 g

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
42 Manual, 02/2018, A5E03727049-AJ
BaseUnits for I/O modules
4.7 BU type A1, light-colored version, without additional terminals

4.7 BU type A1, light-colored version, without additional terminals

Short designation
Short designation: BU15-P16+A0+2D/T

4.7.1 Product overview

Delivery options (packing unit VPE)


6ES7193-6BP00-0DA1 (VPE: 1 unit)

View

Figure 4-11 BU type A1, light-colored version, without additional terminals

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
Manual, 02/2018, A5E03727049-AJ 43
BaseUnits for I/O modules
4.7 BU type A1, light-colored version, without additional terminals

Properties
● BaseUnit for all I/O modules of BaseUnit type "A1". Can be recognized by the laser
inscription on the front and/or the last two digits of the article number.

Note
Using another I/O module can trigger an internal, non-exchangeable fuse and you must
exchange the terminal box.

– Supply voltage (L+ terminal, ground): Max. 24 V DC/10 A


– Current-carrying capacity per process terminal (terminal 1 to 16): Max. 2 A
● The BaseUnit opens up a new potential group. The self-assembling voltage buses P1 and
P2, and the AUX busbar are interrupted to the left-hand neighboring module (BaseUnit,
interface module).
● No access to the AUX busbar via terminals
● 16 terminals to the process (assignment through the I/O module)
● Recording of the terminal temperature for internal temperature compensation at
connected thermocouples
● Connection system in the form of push-in terminals Connection cross-sections are
available in the ET 200SP System Manual
(https://support.industry.siemens.com/cs/ww/de/view/58649293).

Maximum configuration per potential group


The number of I/O modules that can be used per potential group depends on the following
factors:
1. Total power requirement of all I/O modules operated on this potential group
2. Total power requirement of all loads connected externally to this potential group
The total current calculated according to item 1. and item 2. must not exceed 10 A.

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
44 Manual, 02/2018, A5E03727049-AJ
BaseUnits for I/O modules
4.7 BU type A1, light-colored version, without additional terminals

4.7.2 Connection

Pin assignment

Pin assignment for BU type A1, light-colored version, without additional terminals
Terminal Descriptions
1 to 16 Assignment is determined by the I/O module. You can find additional infor-
mation in the I/O Module
(http://support.automation.siemens.com/WW/view/en/55679691/133300)
manual.
(AUX) No access to the AUX busbar via terminals
L+, P1 / M, P2 L+: Rated supply voltage 24 V DC with max. 10 A
M: Ground

Block diagram

① Backplane bus
② I/O module
③ Internal reference junction for temperature compensation
④ Terminals with connection to the I/O module
⑤ System-integrated, self-assembling voltage buses P1, P2 with connection to the supply termi-
nals, interrupted to the adjacent module on the left (forms a new potential group)
⑥ System-integrated, self-assembling AUX voltage bus without connection to the AUX terminals,
interrupted to the adjacent module on the left (forms a new potential group)

Figure 4-12 Block diagram of the BU type A1, light-colored version, without additional terminals

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
Manual, 02/2018, A5E03727049-AJ 45
BaseUnits for I/O modules
4.7 BU type A1, light-colored version, without additional terminals

4.7.3 Technical specifications

Technical specifications of the BU type A1, light-colored version, without additional


terminals

Article number 6ES7193-6BP00-0DA1


General information
Product type designation Type A1
Supply voltage
Rated value (DC) 24 V
external protection for power supply lines Yes; 24 V DC/10 A miniature circuit breaker with
type B or C tripping characteristic
Current carrying capacity
For P1 and P2 bus, max. 10 A
For process terminals, max. 2A
Hardware configuration
Temperature sensor Yes
Formation of potential groups
• New potential group Yes

• Potential group continued from the left No

Potential separation
between the potential groups Yes
Isolation
Isolation tested with 707 V DC (type test)
Accessories
Color coding labels
• for process terminals CC00 to CC09

• for AUX terminals does not exist

• for add-on terminals does not exist

Connection method
Terminals
• Terminal type Push-in terminal

• Conductor cross-section, min. 0.14 mm²; AWG 26

• Conductor cross-section, max. 2.5 mm²; AWG 14

• Number of process terminals to I/O module 16

• Number of terminals to AUX bus 0

• Number of add-on terminals 0

• Number of terminals with connection to P1 2


and P2 bus

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
46 Manual, 02/2018, A5E03727049-AJ
BaseUnits for I/O modules
4.7 BU type A1, light-colored version, without additional terminals

Article number 6ES7193-6BP00-0DA1


Dimensions
Width 15 mm
Height 117 mm
Depth 35 mm
Weights
Weight, approx. 40 g

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
Manual, 02/2018, A5E03727049-AJ 47
BaseUnits for I/O modules
4.8 BU type A1, dark-colored version, with additional terminals

4.8 BU type A1, dark-colored version, with additional terminals

Short designation
Short designation: BU15-P16+A0+12B/T

4.8.1 Product overview

Delivery options (packing unit VPE)


6ES7193-6BP40-0BA1 (VPE: 1 unit)

View

Figure 4-13 BU type A1, dark-colored version, with additional terminals

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
48 Manual, 02/2018, A5E03727049-AJ
BaseUnits for I/O modules
4.8 BU type A1, dark-colored version, with additional terminals

Properties
● BaseUnit suitable for all I/O modules of BaseUnit type "A1". Can be recognized by the
laser inscription on the front and/or the last two digits of the article number.

Note
Using another I/O module can trigger an internal, non-exchangeable fuse and you must
exchange the terminal box.

– Current-carrying capacity per process terminal (terminal 1 to 16): Max. 2 A


● The BaseUnit conducts the potential group further. The self-assembling voltage buses P1
and P2, and the AUX busbar are connected to the left-hand neighboring module
(BaseUnit).
● No access to the AUX busbar via terminals
● 16 terminals to the process (assignment through the I/O module)
● 2x5 additional terminals for supplying a supply voltage up to 24 V DC/ 10 A. The
additional terminals are not connected to the I/O module.
● Recording of the terminal temperature for internal temperature compensation at
connected thermocouples
● Connection system in the form of push-in terminals Connection cross-sections are
available in the ET 200SP System Manual
(https://support.industry.siemens.com/cs/ww/de/view/58649293).

4.8.2 Connection

Pin assignment

Pin assignment for BU type A1, dark-colored version, with additional terminals
Terminal Descriptions
1 to 16 Assignment is determined by the I/O module. You can find additional infor-
mation in the I/O Module
(http://support.automation.siemens.com/WW/view/en/55679691/133300)
manual.
1 B, 2 B, 3 B, 4 B, 2 x 5 add-on terminals for the infeed of a supply voltage up to 24 V DC with
5B/ max. 10 A
1 C, 2 C, 3 C, 4 C,
5C
(AUX) No access to the AUX busbar via terminals
L+, P1 / M, P2 L+: Rated supply voltage 24 V DC with max. 10 A
M: Ground

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
Manual, 02/2018, A5E03727049-AJ 49
BaseUnits for I/O modules
4.8 BU type A1, dark-colored version, with additional terminals

Block diagram

① Backplane bus
② I/O module
③ Internal reference junction for temperature compensation
④ Terminals with connection to the I/O module
⑤ Additional terminals for feeding an additional supply voltage
⑥ System-integrated, self-assembling voltage buses P1, P2 with connection to the supply termi-
nals, connected to the adjacent module on the left
⑦ System-integrated, self-assembling AUX voltage bus without connection to the AUX terminals,
connected to the adjacent module on the left

Figure 4-14 Block diagram of the BU type A1, dark-colored version, with additional terminals

4.8.3 Technical specifications

Technical specifications of the BU type A1, dark-colored version, with additional terminals

Article number 6ES7193-6BP40-0BA1


General information
Product type designation Type A1
Supply voltage
Rated value (DC) 24 V
external protection for power supply lines Yes; 24 V DC/10 A miniature circuit breaker with
type B or C tripping characteristic

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
50 Manual, 02/2018, A5E03727049-AJ
BaseUnits for I/O modules
4.8 BU type A1, dark-colored version, with additional terminals

Article number 6ES7193-6BP40-0BA1


Current carrying capacity
For P1 and P2 bus, max. 10 A
For process terminals, max. 2A
Hardware configuration
Additional terminals Yes
Temperature sensor Yes
Formation of potential groups
• New potential group No

• Potential group continued from the left Yes

Isolation
Isolation tested with 707 V DC (type test)
Accessories
Color coding labels
• for process terminals CC00 to CC09

• for AUX terminals does not exist

• for add-on terminals CC74

Connection method
Terminals
• Terminal type Push-in terminal

• Conductor cross-section, min. 0.14 mm²; AWG 26

• Conductor cross-section, max. 2.5 mm²; AWG 14

• Number of process terminals to I/O module 16

• Number of terminals to AUX bus 0

• Number of add-on terminals 0

• Number of terminals with connection to P1 2


and P2 bus
Dimensions
Width 15 mm
Height 141 mm
Depth 35 mm
Weights
Weight, approx. 50 g

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
Manual, 02/2018, A5E03727049-AJ 51
BaseUnits for I/O modules
4.9 BU type A1, dark-colored version, without additional terminals

4.9 BU type A1, dark-colored version, without additional terminals

Short designation
Short designation: BU15-P16+A0+2B/T

4.9.1 Product overview

Delivery options (packing unit VPE)


6ES7193-6BP00-0BA1 (VPE: 1 unit)

View

Figure 4-15 BU type A1, dark-colored version, without additional terminals

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
52 Manual, 02/2018, A5E03727049-AJ
BaseUnits for I/O modules
4.9 BU type A1, dark-colored version, without additional terminals

Properties
● BaseUnit suitable for all I/O modules of BaseUnit type "A1". Can be recognized by the
laser inscription on the front and/or the last two digits of the article number.

Note
Using another I/O module can trigger an internal, non-exchangeable fuse and you must
exchange the terminal box.

– Current-carrying capacity per process terminal (terminal 1 to 16): Max. 2 A


● The BaseUnit conducts the potential group further. The self-assembling voltage buses P1
and P2, and the AUX busbar are connected to the left-hand neighboring module
(BaseUnit).
● No access to the AUX busbar via terminals
● 16 terminals to the process (assignment through the I/O module)
● Recording of the terminal temperature for internal temperature compensation at
connected thermocouples
● Connection system in the form of push-in terminals Connection cross-sections are
available in the ET 200SP System Manual
(https://support.industry.siemens.com/cs/ww/de/view/58649293).

4.9.2 Connection

Pin assignment

Pin assignment for BU type A1, dark-colored version, without additional terminals
Terminal Descriptions
1 to 16 Assignment is determined by the I/O module. You can find additional infor-
mation in the I/O Module
(http://support.automation.siemens.com/WW/view/en/55679691/133300)
manual.
(AUX) No access to the AUX busbar via terminals
L+, P1 / M, P2 L+: Rated supply voltage 24 V DC with max. 10 A
M: Ground

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
Manual, 02/2018, A5E03727049-AJ 53
BaseUnits for I/O modules
4.9 BU type A1, dark-colored version, without additional terminals

Block diagram

① Backplane bus
② I/O module
③ Internal reference junction for temperature compensation
④ Terminals with connection to the I/O module
⑤ System-integrated, self-assembling voltage buses P1, P2 with connection to the supply termi-
nals, connected to the adjacent module on the left
⑥ System-integrated, self-assembling AUX voltage bus without connection to the AUX terminals,
connected to the adjacent module on the left

Figure 4-16 Block diagram of the BU type A1, dark-colored version, without additional terminals

4.9.3 Technical specifications

Technical specifications of the BU type A1, dark-colored version, without additional terminals

Article number 6ES7193-6BP00-0BA1


General information
Product type designation Type A1
Supply voltage
Rated value (DC) 24 V
external protection for power supply lines Yes; 24 V DC/10 A miniature circuit breaker with
type B or C tripping characteristic
Current carrying capacity
For P1 and P2 bus, max. 10 A
For process terminals, max. 2A
Hardware configuration
Temperature sensor Yes

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
54 Manual, 02/2018, A5E03727049-AJ
BaseUnits for I/O modules
4.9 BU type A1, dark-colored version, without additional terminals

Article number 6ES7193-6BP00-0BA1


Formation of potential groups
• New potential group No

• Potential group continued from the left Yes

Isolation
Isolation tested with 707 V DC (type test)
Accessories
Color coding labels
• for process terminals CC00 to CC09

• for AUX terminals does not exist

• for add-on terminals does not exist

Connection method
Terminals
• Terminal type Push-in terminal

• Conductor cross-section, min. 0.14 mm²; AWG 26

• Conductor cross-section, max. 2.5 mm²; AWG 14

• Number of process terminals to I/O module 16

• Number of terminals to AUX bus 0

• Number of add-on terminals 0

• Number of terminals with connection to P1 2


and P2 bus
Dimensions
Width 15 mm
Height 117 mm
Depth 35 mm
Weights
Weight, approx. 40 g

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
Manual, 02/2018, A5E03727049-AJ 55
BaseUnits for I/O modules
4.10 BU type B0, dark-colored version, with AUX terminals, supply over P1, P2 busbar

4.10 BU type B0, dark-colored version, with AUX terminals, supply over
P1, P2 busbar

Short designation
Short designation: BU20-P12+A4+0B

4.10.1 Product overview

Delivery options (packing unit VPE)


6ES7193-6BP20-0BB0 (VPE: 1 unit)
6ES7193-6BP20-2BB0 (VPE: 10 units)

View

Figure 4-17 BU type B0, dark-colored version, with AUX terminals, supply over P1, P2 busbar

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
56 Manual, 02/2018, A5E03727049-AJ
BaseUnits for I/O modules
4.10 BU type B0, dark-colored version, with AUX terminals, supply over P1, P2 busbar

Properties
● BaseUnit suitable for all I/O modules of the BaseUnit type "B0/B1". Can be recognized by
the laser inscription on the front and/or the last two digits of the article number.
– Current-carrying capacity per process terminal (terminal 1 to 12): Max. 5 A
● The BaseUnit conducts the potential group further. The self-assembling voltage buses P1
and P2, and the AUX busbar are connected to the left-hand neighboring module
(BaseUnit).
● Access to the AUX busbar via terminals
● 12 terminals to the process (assignment with the I/O module)
● Connection system in the form of push-in terminals Connection cross-sections are
available in the ET 200SP System Manual
(https://support.industry.siemens.com/cs/ww/de/view/58649293).

4.10.2 Connecting

Pin assignment

Pin assignment for BU type B0, dark-colored version, with AUX terminals, supply over P1, P2 busbar
Terminal Descriptions
1 to 12 Assignment is determined by the I/O module.
You can find additional information in the I/O Module
(http://support.automation.siemens.com/WW/view/en/55679691/133300)
manual.
1 A, 2 A, 3 A, 4 A, AUX Protective conductor connection or voltage bus. Freely usable up to
230 V AC/DC with max 10 A. If you connect a voltage, it must belong to
the same potential group as the rated supply voltage.

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
Manual, 02/2018, A5E03727049-AJ 57
BaseUnits for I/O modules
4.10 BU type B0, dark-colored version, with AUX terminals, supply over P1, P2 busbar

Block diagram

① Backplane bus
② I/O module
③ Terminals with connection to the I/O module
④ System-integrated, self-assembling voltage buses P1, P2 with connection to the supply termi-
nals, connected to the adjacent module on the left
⑤ System-integrated, self-assembling AUX voltage bus with connection to the 4 AUX terminals,
connected to the adjacent module on the left

Figure 4-18 Block diagram of the BU type B0, dark-colored version, with AUX terminals, supply over
P1, P2 busbar

4.10.3 Technical specifications

Technical specifications of the BU type B0, dark-colored version, with AUX terminals,
supply over P1, P2 busbar

Article number 6ES7193-6BP20-0BB0


General information
Product type designation Type B0
Supply voltage
Rated value (DC) 24 V
Rated value (AC) 230 V; 110 V
Current carrying capacity
up to 60 °C, max. 10 A
Potential separation
between backplane bus and supply voltage Yes

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
58 Manual, 02/2018, A5E03727049-AJ
BaseUnits for I/O modules
4.10 BU type B0, dark-colored version, with AUX terminals, supply over P1, P2 busbar

Article number 6ES7193-6BP20-0BB0


Isolation
Isolation tested with 3 250 V DC
Dimensions
Width 20 mm
Height 117 mm
Depth 35 mm
Weights
Weight, approx. 48 g

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
Manual, 02/2018, A5E03727049-AJ 59
BaseUnits for I/O modules
4.11 BU type B1, dark-colored version, without AUX terminals, supply over supply terminals

4.11 BU type B1, dark-colored version, without AUX terminals, supply


over supply terminals

Short designation
Short designation: BU20-P12+A0+4B

4.11.1 Product overview

Delivery options (packing unit VPE)


6ES7193-6BP20-0BB1 (VPE: 1 unit)
6ES7193-6BP20-2BB1 (VPE: 10 units)

View

Figure 4-19 BU type B1, dark-colored version, without AUX terminals, supply over supply terminals

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
60 Manual, 02/2018, A5E03727049-AJ
BaseUnits for I/O modules
4.11 BU type B1, dark-colored version, without AUX terminals, supply over supply terminals

Properties
● BaseUnit suitable for all I/O modules of the BaseUnit type "B1". Can be recognized by the
laser inscription on the front and/or the last two digits of the article number.
– Current-carrying capacity per process terminal (terminal 1 to 12): Max. 5 A
● The BaseUnit conducts the potential group further. The self-assembling voltage buses P1
and P2, and the AUX busbar are connected to the left-hand neighboring module
(BaseUnit).
● No access to the power and AUX busbars via terminals
● 12 terminals to the process (assignment with the I/O module)
● Connection system in the form of push-in terminals Connection cross-sections are
available in the ET 200SP System Manual
(https://support.industry.siemens.com/cs/ww/de/view/58649293).

4.11.2 Connecting up

Pin assignment

Pin assignment for BU type B1, dark-colored version, without AUX terminals, supply over supply
terminals
Terminal Descriptions
1 to 12 Assignment is determined by the I/O module.
You can find additional information in the I/O Module
(http://support.automation.siemens.com/WW/view/de/55679691/133300)
manual.
(AUX) No access to the AUX busbar via terminals
1 L, 2 L, (P1) / 1 N, 2 N, 1 L, 2 L: Rated supply voltage up to 230 V AC with max. 10 A
(P2) 1 N, 2 N: Neutral/Ground

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
Manual, 02/2018, A5E03727049-AJ 61
BaseUnits for I/O modules
4.11 BU type B1, dark-colored version, without AUX terminals, supply over supply terminals

Block diagram

① Backplane bus
② I/O module
③ Terminals with connection to the I/O module
④ System-integrated, self-assembling voltage buses P1, P2 without connection to the terminals,
connected to the adjacent module on the left
⑤ System-integrated, self-assembling AUX voltage bus without connection to the AUX terminals,
connected to the adjacent module on the left

Figure 4-20 Block diagram of the BU type B1, dark-colored version, without AUX terminals, supply
over supply terminals

4.11.3 Technical specifications

Technical specifications of the BU type B1, dark-colored version, without AUX terminals,
supply over supply terminals

Article number 6ES7193-6BP20-0BB1


General information
Product type designation Type B1
Supply voltage
Rated value (DC) 24 V
Rated value (AC) 230 V; 110 V
Current carrying capacity
up to 60 °C, max. 10 A

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
62 Manual, 02/2018, A5E03727049-AJ
BaseUnits for I/O modules
4.11 BU type B1, dark-colored version, without AUX terminals, supply over supply terminals

Article number 6ES7193-6BP20-0BB1


Potential separation
between backplane bus and supply voltage Yes
between process terminals and supply voltage Yes
between power bus and supply voltage Yes
Isolation
Isolation tested with 3 250 V DC
Dimensions
Width 20 mm
Height 117 mm
Depth 35 mm
Weights
Weight, approx. 48 g

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
Manual, 02/2018, A5E03727049-AJ 63
BaseUnits for I/O modules
4.12 BU type C0, light-colored version, with AUX terminals, supply over supply terminals

4.12 BU type C0, light-colored version, with AUX terminals, supply over
supply terminals

Short designation
Short designation: BU20-P6+A2+4D

4.12.1 Product overview

Delivery options (packing unit VPE)


6ES7193-6BP20-0DC0 (VPE: 1 unit)

View

Figure 4-21 BU type C0, light-colored version, with AUX terminals, supply over supply terminals

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
64 Manual, 02/2018, A5E03727049-AJ
BaseUnits for I/O modules
4.12 BU type C0, light-colored version, with AUX terminals, supply over supply terminals

Properties
● BaseUnit suitable for all I/O modules of BaseUnit type "C0/C1". Can be recognized by the
laser inscription on the front and/or the last two digits of the article number.
– Supply voltage (terminal 1 L, 2 / 1 N, 2 N): Max. 230 V AC/10 A
– Current-carrying capacity per process terminal (terminal 1 to 4): Max. 5 A
– Current carrying capacity per process terminal (terminal 5 and 6): Max. 10 A
● The BaseUnit opens up a new potential group by means of the inserted I/O module. The
self-assembling voltage buses P1 and P2, and the AUX busbar are interrupted to the left-
hand neighboring module (BaseUnit, interface module).
● Access to the AUX busbar via terminals
● 6 terminals to the process (assignment with the I/O module)
● Two AUX terminals for connecting a PE terminal or potential. The AUX busbar is not
connected to the I/O module. Max. 24 V DC/10 A
● Connection system in the form of push-in terminals You can find more information in the
ET 200SP System Manual
(https://support.industry.siemens.com/cs/ww/de/view/58649293).

Maximum configuration per potential group


The number of I/O modules that can be used per potential group depends on the following
factors:
1. Total power requirement of all I/O modules operated on this potential group
2. Total power requirement of all loads connected externally to this potential group
The total current calculated according to item 1. and item 2. must not exceed 10 A.

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
Manual, 02/2018, A5E03727049-AJ 65
BaseUnits for I/O modules
4.12 BU type C0, light-colored version, with AUX terminals, supply over supply terminals

4.12.2 Connecting

Pin assignment

Pin assignment for BU type C0, light-colored version, with AUX terminals, supply over supply
terminals
Terminal Descriptions
1 to 6 Assignment is determined by the I/O module.
You can find additional information in the I/O Module
(http://support.automation.siemens.com/WW/view/en/55679691/133300)
manual.
1 A, 2 A, AUX Protective conductor connection or voltage bus, freely usable up to
230 V AC/DC with max. 10 A. If you connect a voltage, it must belong to
the same potential group as the rated supply voltage.
1 L, 2 L, (P1) / 1 N, 2 N, 1 L, 2 L: Rated supply voltage up to 230 V AC with max. 10 A
(P2) 1 N, 2 N: Neutral/Ground

Block diagram

① Backplane bus
② I/O module
③ Terminals with connection to the I/O module
④ System-integrated, self-assembling voltage buses P1, P2 with connection to the supply termi-
nals (through the inserted I/O module) Interrupted to the adjacent module on the left (forms a
new potential group)
⑤ System-integrated, self-assembling AUX voltage bus with connection to the AUX terminals,
interrupted to the adjacent module on the left (forms a new potential group)

Figure 4-22 Block diagram of the BU type C0, light-colored version, with AUX terminals, supply over
supply terminals

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
66 Manual, 02/2018, A5E03727049-AJ
BaseUnits for I/O modules
4.12 BU type C0, light-colored version, with AUX terminals, supply over supply terminals

4.12.3 Technical specifications

Technical specifications of the BU type C0, light-colored version, with AUX terminals,
supply over supply terminals

Article number 6ES7193-6BP20-0DC0


General information
Product type designation Type C0
Supply voltage
Rated value (DC) 24 V; 30 V
Rated value (AC) 230 V; 110 V
external protection for power supply lines Yes; 10 A miniature circuit breaker with type B or
C tripping characteristic for the respective rated
supply voltage
Current carrying capacity
up to 60 °C, max. 10 A
Potential separation
between backplane bus and supply voltage Yes
between process terminals and supply voltage Yes
Isolation
Isolation tested with 3 250 V DC
Dimensions
Width 20 mm
Height 117 mm
Depth 35 mm
Weights
Weight, approx. 47 g

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
Manual, 02/2018, A5E03727049-AJ 67
BaseUnits for I/O modules
4.13 BU type C1, dark-colored version, with AUX terminals, supply over P1, P2 busbar

4.13 BU type C1, dark-colored version, with AUX terminals, supply over
P1, P2 busbar

Short designation
Short designation: BU20-P6+A2+4B

4.13.1 Product overview

Delivery options (packing unit VPE)


6ES7193-6BP20-0BC1 (VPE: 1 unit)

View

Figure 4-23 BU type C1, dark-colored version, with AUX terminals, supply over P1, P2 busbar

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
68 Manual, 02/2018, A5E03727049-AJ
BaseUnits for I/O modules
4.13 BU type C1, dark-colored version, with AUX terminals, supply over P1, P2 busbar

Properties
● BaseUnit suitable for all I/O modules of BaseUnit type "C0/C1". Can be recognized by the
laser inscription on the front and/or the last two digits of the article number.
– Current-carrying capacity per process terminal (terminal 1 to 4): Max. 5 A
– Current carrying capacity per process terminal (terminal 5 and 6): Max. 10 A
● The BaseUnit further conducts the potential group. The self-assembling voltage buses P1
and P2, and the AUX bus are connected to the left-hand neighboring module (BaseUnit).
● Access to the AUX busbar via terminals
● 6 terminals to the process (assignment with the I/O module)
● Two AUX terminals for connecting a PE terminal or potential. The AUX busbar is not
connected to the I/O module. Max. 24 V DC/10 A
● Connection system in the form of push-in terminals Connection cross-sections are
available in the ET 200SP System Manual
(https://support.industry.siemens.com/cs/ww/de/view/58649293).

4.13.2 Connecting

Pin assignment

Pin assignment for BU type C1, dark-colored version, with AUX terminals, supply over P1, P2 busbar
Terminal Descriptions
1 to 6 Assignment is determined by the I/O module.
You can find additional information in the I/O Module
(http://support.automation.siemens.com/WW/view/en/55679691/133300)
manual.
1 A, 2 A, AUX Protective conductor connection or voltage bus, freely usable up to
230 V AC/DC with max 10 A. If you connect a voltage, it must belong to
the same potential group as the rated supply voltage.
1 L, 2 L, (P1) / 1 N, 2 N, 1 L, 2 L: Rated supply voltage up to 230 V AC with max. 10 A
(P2) 1 N, 2 N: Neutral/Ground

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
Manual, 02/2018, A5E03727049-AJ 69
BaseUnits for I/O modules
4.13 BU type C1, dark-colored version, with AUX terminals, supply over P1, P2 busbar

Block diagram

① Backplane bus
② Power module
③ Terminals with connection to the I/O module
④ System-integrated, self-assembling voltage buses P1, P2 with connection to the supply termi-
nals (through the inserted I/O module) Connected to the adjacent module on the left
⑤ System-integrated, self-assembling AUX voltage bus with connection to the AUX terminals,
connected to the adjacent module on the left

Figure 4-24 Block diagram of the BU type C1, dark-colored version, with AUX terminals, supply over
P1, P2 busbar

4.13.3 Technical specifications

Technical specifications of the BU type C1, dark-colored version, with AUX terminals,
supply over P1, P2 busbar

Article number 6ES7193-6BP20-0BC1


General information
Product type designation Type C1
Supply voltage
Rated value (DC) 24 V; 30 V
Rated value (AC) 230 V; 110 V
Current carrying capacity
up to 60 °C, max. 10 A

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
70 Manual, 02/2018, A5E03727049-AJ
BaseUnits for I/O modules
4.13 BU type C1, dark-colored version, with AUX terminals, supply over P1, P2 busbar

Article number 6ES7193-6BP20-0BC1


Potential separation
between backplane bus and supply voltage Yes
between process terminals and supply voltage Yes
Isolation
Isolation tested with 3 250 V DC
Dimensions
Width 20 mm
Height 117 mm
Depth 35 mm
Weights
Weight, approx. 47 g

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
Manual, 02/2018, A5E03727049-AJ 71
BaseUnits for I/O modules
4.14 BU type D0, dark-colored version, without AUX terminals, supply over supply terminals

4.14 BU type D0, dark-colored version, without AUX terminals, supply


over supply terminals

Short designation
Short designation: BU20-P12+A0+0B

4.14.1 Product overview

Delivery options (packing unit VPE)


6ES7193-6BP00-0BD0 (VPE: 1 unit)

View

Figure 4-25 BU type D0, dark-colored version, without AUX terminals, supply over supply terminals

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
72 Manual, 02/2018, A5E03727049-AJ
BaseUnits for I/O modules
4.14 BU type D0, dark-colored version, without AUX terminals, supply over supply terminals

Properties
● BaseUnit suitable for all I/O modules of the BaseUnit type "D0". Can be recognized by the
laser inscription on the front and/or the last two digits of the article number.
– Current-carrying capacity per process terminal (terminal 1 to 12): Max. 5 A
● The BaseUnit further conducts the potential group. The self-assembling voltage buses P1
and P2, and the AUX busbar are connected to the left-hand neighboring module
(BaseUnit).
● No access to the power and AUX busbars via terminals
● 12 terminals to the process (assignment with the I/O module)
● Connection system in the form of push-in terminals Connection cross-sections are
available in the ET 200SP System Manual
(https://support.industry.siemens.com/cs/ww/de/view/58649293).

Note
The shield connection (shield support and shield terminal) is not intended for BaseUnit
BU20-P12+A0+0B and must not be installed.

4.14.2 Connecting

Pin assignment

Pin assignment for BU type D0, dark-colored version, without AUX terminals, supply over supply
terminals
Terminal Descriptions
1 to 12 Assignment is determined by the I/O module.
You can find additional information in the I/O Module
(http://support.automation.siemens.com/WW/view/en/55679691/133300)
manual.
(AUX) No access to the AUX busbar via terminals

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
Manual, 02/2018, A5E03727049-AJ 73
BaseUnits for I/O modules
4.14 BU type D0, dark-colored version, without AUX terminals, supply over supply terminals

Block diagram

① Backplane bus
② I/O module
③ Terminals with connection to the I/O module
④ System-integrated, self-assembling voltage buses P1, P2 without connection to the terminals,
connected to the adjacent module on the left
⑤ System-integrated, self-assembling AUX voltage bus without connection to the AUX terminals,
connected to the adjacent module on the left

Figure 4-26 Block diagram of the BU type D0, dark-colored version, without AUX terminals, supply
over supply terminals

4.14.3 Technical specifications

Technical specifications of the BU type D0, dark-colored version, without AUX terminals,
supply over supply terminals

Article number 6ES7193-6BP00-0BD0


General information
Product type designation Type D0
Supply voltage
Rated value (AC) 400 V; 230 V AC (L1, N)
Current carrying capacity
up to 60 °C, max. 5A
Isolation
Isolation tested with 3 250 V DC
Dimensions
Width 20 mm
Height 117 mm
Depth 35 mm
Weights
Weight, approx. 47 g

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
74 Manual, 02/2018, A5E03727049-AJ
BaseUnits for I/O modules
4.15 BU type F0, dark-colored version, with AUX terminals, supply over supply terminals

4.15 BU type F0, dark-colored version, with AUX terminals, supply over
supply terminals

Short designation
Short designation: BU20-P8+A4+0B

4.15.1 Product overview


When you use the AUX terminals as a PE busbar:

NOTICE

When AUX is used as PE, AUX must be identified as green-yellow (e.g., gn/ye color-coded
labels). These identifications must be removed if the terminals are no longer used as PE.

Delivery options (packing unit VPE)


6ES7193-6BP20-0BF0 (VPE: 1 unit)

View

Figure 4-27 BU type F0, dark-colored version, with AUX terminals, supply over supply terminals

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
Manual, 02/2018, A5E03727049-AJ 75
BaseUnits for I/O modules
4.15 BU type F0, dark-colored version, with AUX terminals, supply over supply terminals

Properties
● BaseUnit suitable for all I/O modules of the BaseUnit type "F0". Can be recognized by the
laser inscription on the front and/or the last two digits of the article number.
– Current carrying capacity per process terminal (terminals 1 to 4 and 9 to 12): Max. 5 A
● The BaseUnit loops the potential group through with the self-assembling voltage buses
P1, P2 and the AUX bus of the left-hand neighboring module (BaseUnit).
● Access to the AUX busbar via terminals 1 A to 4 A max. 24 V DC/10 A
● 8 terminals to the process (occupied by the I/O module)
● Connection system in the form of push-in terminals Connection cross-sections are
available in the ET 200SP System Manual
(https://support.industry.siemens.com/cs/ww/de/view/58649293).

4.15.2 Connecting up

Pin assignment

Pin assignment for BU type F0, dark-colored version, with AUX terminals, supply over supply
terminals
Terminals of a potential Fail-safe module Non-fail-safe module
group Overvoltage category 3 Overvoltage category 2
1 to 4 Up to 230 V AC/DC (AC only one phase)
Assignment is determined by the I/O module.
You can find additional information in the I/O Module
(http://support.automation.siemens.com/WW/view/en/55679691/13330
0) manual.
9 to 12 Safe extra low voltage SELV/PELV
Assignment is determined by the I/O module.
You can find additional information in the I/O Module
(http://support.automation.siemens.com/WW/view/en/55679691/13330
0) manual.
P1, P2, AUX (1 A to 4 A) SELV/PELV SELV/PELV
(max. 10 A) or
up to 230 V AC/DC (AC only one
phase)
(max. 10 A)

Use the AUX terminals only with an identical voltage or PE associated with the supply
voltage.

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
76 Manual, 02/2018, A5E03727049-AJ
BaseUnits for I/O modules
4.15 BU type F0, dark-colored version, with AUX terminals, supply over supply terminals

Block diagram

① Backplane bus
② I/O module
③ Terminals with connection to the I/O module
④ System-integrated, self-assembling voltage buses P1, P2 without connection to the terminals,
connected to the adjacent module on the left
⑤ System-integrated, self-assembling AUX voltage bus with connection to the AUX terminals,
connected to the adjacent module on the left

Figure 4-28 Block diagram of the BU type F0, dark-colored version, with AUX terminals, supply over
supply terminals

4.15.3 Technical specifications

Technical specifications of the BU type F0, dark-colored version, with AUX terminals,
supply over supply terminals

Article number 6ES7193-6BP20-0BF0


General information
Product type designation Type F0
Supply voltage
Rated value (DC) See manual
Rated value (AC) See manual
Current carrying capacity
up to 60 °C, max. 10 A

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
Manual, 02/2018, A5E03727049-AJ 77
BaseUnits for I/O modules
4.15 BU type F0, dark-colored version, with AUX terminals, supply over supply terminals

Article number 6ES7193-6BP20-0BF0


Potential separation
between backplane bus and supply voltage Yes
between process terminals and supply voltage Yes
between power bus and supply voltage Yes
Isolation
Isolation tested with 3 250 V DC/1 min (type test), 2 545 V DC/2 s
(routine test)
Dimensions
Width 20 mm
Height 117 mm
Depth 35 mm
Weights
Weight, approx. 48 g

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
78 Manual, 02/2018, A5E03727049-AJ
BaseUnits for I/O modules
4.16 BU type U0, light-colored version without AUX terminals

4.16 BU type U0, light-colored version without AUX terminals

Short designation
Short designation: BU20-P16+A0+2D

4.16.1 Product overview

Delivery options (packing unit VPE)


6ES7193-6BP00-0DU0 (VPE: 1 unit)
6ES7193-6BP00-2DU0 (VPE: 10 units)

View

Figure 4-29 BU type U0, light-colored version without AUX terminals

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
Manual, 02/2018, A5E03727049-AJ 79
BaseUnits for I/O modules
4.16 BU type U0, light-colored version without AUX terminals

Properties
● BaseUnit suitable for all I/O modules of the BaseUnit type "U0". Can be recognized by the
laser inscription on the front and/or the last two digits of the article number.
– Current-carrying capacity per process terminal (terminal 1 to 16): Max. 10 A
● The BaseUnit opens up a new potential group. The self-assembling voltage buses P1, P2
and the AUX busbar are disconnected from the adjacent module on the left (BaseUnit,
interface module, CPU).
● No access to the AUX busbar via terminals
● 16 terminals to the process (assignment through the I/O module)
● Connection system in the form of push-in terminals Connection cross-sections are
available in the ET 200SP System Manual
(https://support.industry.siemens.com/cs/ww/de/view/58649293).

Maximum configuration per potential group


The number of I/O modules that can be used per potential group depends on the following
factors:
1. Total power requirement of all I/O modules operated on this potential group
2. Total power requirement of all loads connected externally to this potential group
The total current calculated according to item 1. and item 2. must not exceed 10 A.

Note
A potential group opened with light-colored BaseUnit of type U0 must contain no dark-
colored BaseUnit of type A0 or A1.

4.16.2 Connection

Pin assignment

Pin assignment for BU type U0, light-colored version, without AUX terminals
Terminal Descriptions
1 to 16 Assignment is determined by the I/O module. You can find additional infor-
mation in the I/O Module
(http://support.automation.siemens.com/WW/view/de/55679691/133300)
manual.
(AUX) No access to the AUX busbar via terminals
P1 / P2 P1: Rated supply voltage up to 230 V AC with max. 10 A
P2: Neutral/Ground

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
80 Manual, 02/2018, A5E03727049-AJ
BaseUnits for I/O modules
4.16 BU type U0, light-colored version without AUX terminals

Block diagram

① Backplane bus
② I/O module
③ Terminals with connection to the I/O module
④ System-integrated, self-assembling voltage buses P1, P2 with connection to the supply termi-
nals, interrupted to the adjacent module on the left (forms a new potential group)
⑤ System-integrated, self-assembling AUX voltage bus without connection to the AUX terminals,
interrupted to the adjacent module on the left (forms a new potential group)

Figure 4-30 Block diagram of the BU type U0, light-colored version, without AUX terminals

4.16.3 Technical specifications

Technical specifications of the BU type U0, light-colored version without AUX terminals

Article number 6ES7193-6BP00-0DU0


General information
Product type designation BU type U0, BU20-P16+A0+2D, PU 1
Supply voltage
Rated value (DC) 120 V
• For P1 and P2 bus 120 V

• For AUX bus 120 V

Rated value (AC) 240 V; 400 V (L1 - L2 - L3); 240 V (L1, N)


• For P1 and P2 bus 240 V

• For AUX bus 240 V

• for process terminals 240 V

external protection for power supply lines Yes

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
Manual, 02/2018, A5E03727049-AJ 81
BaseUnits for I/O modules
4.16 BU type U0, light-colored version without AUX terminals

Article number 6ES7193-6BP00-0DU0


Mains filter
• integrated Yes

Current carrying capacity


up to 60 °C, max. 10 A
For P1 and P2 bus, max. 10 A
For AUX bus, max. 10 A
For process terminals, max. 10 A
Hardware configuration
Automatic encoding Yes
Formation of potential groups
• New potential group No

• Potential group continued from the left Yes

Potential separation
between backplane bus and supply voltage Yes
between the potential groups Yes
Isolation
Isolation tested with 3 100 V DC for 2 s
Connection method
Terminals
• Terminal type Push-in terminal

• Conductor cross-section, min. 0.14 mm²; 0.2 mm² without wire end ferrule

• Conductor cross-section, max. 2.5 mm²; 1.5 mm² with wire end ferrule

• Number of process terminals to I/O module 16

• Number of terminals to AUX bus 0

• Number of add-on terminals 0

• Number of terminals with connection to P1 2


and P2 bus
Dimensions
Width 20 mm
Height 117 mm
Depth 35 mm
Weights
Weight, approx. 50 g

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
82 Manual, 02/2018, A5E03727049-AJ
BaseUnits for I/O modules
4.17 BU type U0, dark-colored version, without AUX terminals

4.17 BU type U0, dark-colored version, without AUX terminals

Short designation
Short designation: BU20-P16+A0+2B

4.17.1 Product overview

Delivery options (packing unit VPE)


6ES7193-6BP00-0BU0 (VPE: 1 unit)
6ES7193-6BP00-2BU0 (VPE: 10 units)

View

Figure 4-31 BU type U0, dark-colored version, without AUX terminals

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
Manual, 02/2018, A5E03727049-AJ 83
BaseUnits for I/O modules
4.17 BU type U0, dark-colored version, without AUX terminals

Properties
● BaseUnit suitable for all I/O modules of the BaseUnit type "U0". Can be recognized by the
laser inscription on the front and/or the last two digits of the article number.
– Current-carrying capacity per process terminal (terminal 1 to 16): Max. 10 A
● The BaseUnit conducts the potential group further. The self-assembling voltage buses P1
and P2, and the AUX busbar are connected to the left-hand neighboring module
(BaseUnit).
● No access to the AUX busbar via terminals
● 16 terminals to the process (assignment through the I/O module)
● Connection system in the form of push-in terminals Connection cross-sections are
available in the ET 200SP System Manual
(https://support.industry.siemens.com/cs/ww/de/view/58649293).

4.17.2 Connection

Pin assignment

Pin assignment for BU type U0, dark-colored version, without AUX terminals
Terminal Descriptions
1 to 16 Assignment is determined by the I/O module. You can find additional infor-
mation in the I/O Module
(http://support.automation.siemens.com/WW/view/de/55679691/133300)
manual.
(AUX) No access to the AUX busbar via terminals
P1 / P2 P1: Rated supply voltage up to 230 V AC with max. 10 A
P2: Neutral/Ground

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
84 Manual, 02/2018, A5E03727049-AJ
BaseUnits for I/O modules
4.17 BU type U0, dark-colored version, without AUX terminals

Block diagram

① Backplane bus
② I/O module
③ Terminals with connection to the I/O module
④ System-integrated, self-assembling voltage buses P1, P2 with connection to the supply termi-
nals, connected to the adjacent module on the left
④ System-integrated, self-assembling AUX voltage bus without connection to the AUX terminals,
connected to the adjacent module on the left

Figure 4-32 Block diagram of the BU type U0, dark-colored version, without AUX terminals

4.17.3 Technical specifications

Technical specifications of the BU type U0, dark-colored version, without AUX terminals

Article number 6ES7193-6BP00-0BU0


General information
Product type designation BU type U0, BU20-P16+A0+2B, PU 1
Supply voltage
Rated value (DC) 120 V
• For P1 and P2 bus 120 V

• For AUX bus 120 V

Rated value (AC) 240 V; 400 V (L1 - L2 - L3); 240 V (L1, N)


• For P1 and P2 bus 240 V

• For AUX bus 240 V

• for process terminals 240 V

external protection for power supply lines Yes

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
Manual, 02/2018, A5E03727049-AJ 85
BaseUnits for I/O modules
4.17 BU type U0, dark-colored version, without AUX terminals

Article number 6ES7193-6BP00-0BU0


Mains filter
• integrated No

Current carrying capacity


up to 60 °C, max. 10 A
For P1 and P2 bus, max. 10 A
For AUX bus, max. 10 A
For process terminals, max. 10 A
Hardware configuration
Automatic encoding Yes
Formation of potential groups
• New potential group No

• Potential group continued from the left Yes

Potential separation
between backplane bus and supply voltage Yes
Isolation
Isolation tested with 3 100 V DC for 2 s
Connection method
Terminals
• Terminal type Push-in terminal

• Conductor cross-section, min. 0.14 mm²; 0.2 mm² without wire end ferrule

• Conductor cross-section, max. 2.5 mm²; 1.5 mm² with wire end ferrule

• Number of process terminals to I/O module 16

• Number of terminals to AUX bus 0

• Number of add-on terminals 0

• Number of terminals with connection to P1 2


and P2 bus
Dimensions
Width 20 mm
Height 117 mm
Depth 35 mm
Weights
Weight, approx. 50 g

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
86 Manual, 02/2018, A5E03727049-AJ
BaseUnits for motor starters 5
5.1 Introduction
Properties of the infeed bus
● The infeed bus is set up by connecting the BaseUnits, and wiring takes place
automatically
● The infeed bus distributes the energy to the SIMATIC ET 200SP motor starter within one
load group
● The max. current carrying capacity is up to 32 A (3-phase)
– With infeed (for one load group) and motor connection
– Infeed bus: 3-pole + PE
– The voltage range for power infeed is 48 … 500 V AC
You must observe the deratings depending on the configuration.

Properties of the self-assembling voltage bus (power bus)


● Maximum current: 7 A
● Rated voltage: 24 V DC
You must observe the deratings depending on the configuration.

AUX1 bus
The AUX1 bus is not supported in the BaseUnits of the SIMATIC ET 200SP motor starters.
You can find assembly rules of the BaseUnits for the SIMATIC ET 200SP motor starter in the
System Manual SIMATIC ET 200SP motor starters.

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
Manual, 02/2018, A5E03727049-AJ 87
BaseUnits for motor starters
5.2 BU30-MS1 - BaseUnit with 24 V DC and 500 V AC infeed

5.2 BU30-MS1 - BaseUnit with 24 V DC and 500 V AC infeed

5.2.1 Product overview

Article number
3RK1908-0AP00-0AP0

View

Figure 5-1 BaseUnit with 24 V DC and 500 V AC infeed

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
88 Manual, 02/2018, A5E03727049-AJ
BaseUnits for motor starters
5.2 BU30-MS1 - BaseUnit with 24 V DC and 500 V AC infeed

Properties
● BaseUnit suitable for all fail-safe and non-fail-safe SIMATIC ET 200SP High Feature
motor starters
● The BaseUnit opens a new potential group (24 V DC). The power buses P1 and P2 are
interrupted to the left-hand neighboring module (BaseUnit, interface module/CPU).
● The BaseUnit opens a new potential group (500 V DC). The infeed bus L1 (L), L2 (N), L3,
PE is interrupted to the left-hand BaseUnit of the ET 200SP motor starter.
● Connection method using push-in terminals
● The touch protection cover for the infeed bus (3RK1908-1DA00-2BP0) is included in the
scope of delivery.
● The fail-safe input F-DI of the fail-safe motor starter is connected to the power bus.

Maximum configuration per voltage group (24 V DC)


The number of I/O modules that can be used per potential group depends on the following
factors:
1. Total power requirement of all I/O modules operated on this potential group
2. Total power requirement of all loads connected externally to this potential group
The total current calculated according to item 1. and item 2. must not exceed 7 A.

Maximum configuration of the infeed bus (500 V AC)


The number of motor starters that can be used per infeed group depends on the following
factors:
1. Total current requirement of all motor starters operated on this infeed group.
2. Ambient temperature and installation type in which the motor starters are operated.
You can find further information in the derating table in the Manual SIMATIC ET 200SP
motor starters (https://support.industry.siemens.com/cs/ww/en/view/109479973).

5.2.2 Connection

Pin assignment

Pin assignment for BaseUnit with 24 V DC and 500 V AC infeed


Terminal Descriptions
L1(L), L2(N), L3, PE Power supply
Assignment is determined by the motor starter. You can find more infor-
mation in the ET 200SP Motor Starter
(https://support.industry.siemens.com/cs/ww/en/view/109479973) manu-
al.
T1, T2, T3, PE Motor feeder
24 V DC, M 24 V DC: Supply voltage 24 V DC with max. 7 A
M: Ground

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
Manual, 02/2018, A5E03727049-AJ 89
BaseUnits for motor starters
5.2 BU30-MS1 - BaseUnit with 24 V DC and 500 V AC infeed

Block diagram
The figure below shows the block diagram of the BaseUnit with 24 V DC and 500 V AC
infeed.

① Backplane bus
② Motor starter module
③ Interrupted busbars 24 V DC, M
④ Interrupted AUX bus
⑤ Terminals for 24 V DC and ground M
⑥ Interrupted busbars for the infeed system L1(L), L2(N), L3, PE
⑦ Infeed terminal for protective ground PE
⑧ Infeed terminal L3
⑨ Infeed terminal L2(N)
⑩ Infeed terminal L1(L)
⑪ Terminal for protective ground PE
⑫ Terminal T3
⑬ Terminal T2
⑭ Terminal T1

Figure 5-2 Block diagram BaseUnit with 24 V DC and 500 V AC infeed

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
90 Manual, 02/2018, A5E03727049-AJ
BaseUnits for motor starters
5.2 BU30-MS1 - BaseUnit with 24 V DC and 500 V AC infeed

5.2.3 Technical specifications

Technical specifications of the BaseUnit with 24 V DC and 500 V AC infeed

3RK1908-0AP00-0AP0
Product type designation BU30-MS1
Galvanic isolation
Galvanic isolation between backplane bus and Yes
supply voltage
Insulation tested with 2500 V AC
Rated operating voltage 24 V DC
Max. operating current 7 A (observe derating)
Rated insulation voltage in accordance with IEC 500 V
60947-1
Impulse withstand voltage/rated value Uimp accord- 6 kV
ing to IEC 60947-1
Operating voltage range 48 ... 500 V AC
Max. current-carrying capacity 32 A (observe derating)
Isolating function between the infeed terminals 6 kV
L1(L), L2 (N), L3 and motor feeder terminals T1,
T2, T3 for motor starters in parking position, or
removed motor starters: impulse withstand volt-
age/rated value Uimp according to IEC 60947-1
Wiring
Push-in Required tools for releasing: Standard screwdriv-
er size 1 (SZF1 - 0.6x3.5)
Dimensions
Width 30 mm
Height 215 mm
Weights
Weight, approx. 164 g

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
Manual, 02/2018, A5E03727049-AJ 91
BaseUnits for motor starters
5.3 BU30-MS2 - BaseUnit with 500 V AC infeed

5.3 BU30-MS2 - BaseUnit with 500 V AC infeed

5.3.1 Product overview

Article number
3RK1908-0AP00-0CP0

View

Figure 5-3 BaseUnit with 500 V AC infeed

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
92 Manual, 02/2018, A5E03727049-AJ
BaseUnits for motor starters
5.3 BU30-MS2 - BaseUnit with 500 V AC infeed

Properties
● BaseUnit suitable for all fail-safe and non-fail-safe SIMATIC ET 200SP High Feature
motor starters
● The BaseUnit takes over the potential group (P1, P2) from the adjacent module on the
left.
● The BaseUnit opens a new supply group 500 V AC. The potential group (24 V DC) is
further continued
● Connection method using push-in terminals
● The touch protection cover for the infeed bus is included in the scope of delivery.
● The fail-safe input F-DI of the fail-safe motor starter is connected to the power bus.

Maximum configuration of the infeed bus (500 V AC)


The number of motor starters that can be used per infeed group depends on the following
factors:
1. Total current requirement of all motor starters operated on this infeed group.
2. Ambient temperature and installation type in which the motor starters are operated.
You can find further information in the derating table in the Manual SIMATIC ET 200SP
motor starters.

5.3.2 Connection

Pin assignment

Pin assignment for BaseUnit with 500 V AC infeed


Terminal Descriptions
L1(L), L2(N), L3, PE Power supply
Assignment is determined by the motor starter. See Manual ET 200SP
motor starters
(https://support.industry.siemens.com/cs/ww/en/view/109479973).
T1, T2, T3, PE Motor feeder

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
Manual, 02/2018, A5E03727049-AJ 93
BaseUnits for motor starters
5.3 BU30-MS2 - BaseUnit with 500 V AC infeed

Block diagram
The figure below shows the block diagram of the BaseUnit with 500 V AC infeed.

① Backplane bus
② Motor starter module
③ Connected power buses 24 V DC, M
④ Interrupted AUX bus
⑤ Interrupted busbars for the infeed system L1(L), L2(N), L3, PE
⑥ Infeed terminal for protective ground PE
⑦ Infeed terminal L3
⑧ Infeed terminal L2(N)
⑨ Infeed terminal L1(L)
⑩ Terminal for protective ground PE
⑪ Terminal T3
⑫ Terminal T2
⑬ Terminal T1

Figure 5-4 Block diagram BaseUnit with 500 V AC infeed

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
94 Manual, 02/2018, A5E03727049-AJ
BaseUnits for motor starters
5.3 BU30-MS2 - BaseUnit with 500 V AC infeed

5.3.3 Technical specifications

Technical specifications of the BaseUnit with 500 V AC infeed

3RK1908-0AP00-0CP0
Product type designation BU30-MS2
Galvanic isolation
Galvanic isolation between backplane bus and Yes
supply voltage
Insulation tested with 2500 V AC
Rated operating voltage 24 V DC
Max. operating current 7 A (observe derating)
Rated insulation voltage in accordance with IEC 500 V
60947-1
Impulse withstand voltage/rated value Uimp accord- 6 kV
ing to IEC 60947-1
Operating voltage range 48 ... 500 V AC
Max. current-carrying capacity 32 A (observe derating)
Isolating function between the infeed terminals 6 kV
L1(L), L2 (N), L3 and motor feeder terminals T1,
T2, T3 for motor starters in parking position, or
removed motor starters: impulse withstand volt-
age/rated value Uimp according to IEC 60947-1
Wiring
Push-in Required tools for releasing: Standard screwdriv-
er size 1 (SZF1 - 0.6x3.5)
Dimensions
Width 30 mm
Height 215 mm
Weight, approx. 160 g

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
Manual, 02/2018, A5E03727049-AJ 95
BaseUnits for motor starters
5.4 BU30-MS3 - BaseUnit with 24 V DC infeed

5.4 BU30-MS3 - BaseUnit with 24 V DC infeed

5.4.1 Product overview

Article number
3RK1908-0AP00-0BP0

View

Figure 5-5 BaseUnit with 24 V DC infeed

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
96 Manual, 02/2018, A5E03727049-AJ
BaseUnits for motor starters
5.4 BU30-MS3 - BaseUnit with 24 V DC infeed

Properties
● BaseUnit suitable for all fail-safe and non-fail-safe SIMATIC ET 200SP High Feature
motor starters
● The BaseUnit opens a new potential group (24 V DC). The power buses P1 and P2 are
interrupted to the left-hand neighboring module (BaseUnit, interface module/CPU).
● This BaseUnit handles the infeed bus (500 V AC) of the left-hand BaseUnit and loops this
through.
● Connection method using push-in terminals
● The touch protection cover for the infeed bus is not included in the scope of delivery.
● The fail-safe input F-DI of the fail-safe motor starter is connected to the power bus.

Maximum configuration per voltage group (24 V DC)


The number of I/O modules that can be used per potential group depends on the following
factors:
1. Total power requirement of all I/O modules operated on this potential group
2. Total power requirement of all loads connected externally to this potential group
The total current calculated according to item 1. and item 2. must not exceed 7 A.

5.4.2 Connection

Pin assignment

Pin assignment for BaseUnit with 24 V DC infeed


Terminal Descriptions
T1, T2, T3, PE Motor feeder
24 V DC, M 24 V DC: Rated supply voltage 24 V DC with max. 7 A
M: Ground

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
Manual, 02/2018, A5E03727049-AJ 97
BaseUnits for motor starters
5.4 BU30-MS3 - BaseUnit with 24 V DC infeed

Block diagram
The figure below shows the three-phase connection with 24 V infeed and mains infeed.

① Backplane bus
② Motor starter module
③ Interrupted busbars 24 V DC, M
④ Interrupted AUX bus
⑤ Terminal for 24 V DC and ground M
⑥ Connected busbars for the infeed system L1(L), L2(N), L3, PE
⑦ Terminal for protective ground PE
⑧ Terminal T3
⑨ Terminal T2
⑩ Terminal T1

Figure 5-6 Block diagram BaseUnit with 24 V DC infeed

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
98 Manual, 02/2018, A5E03727049-AJ
BaseUnits for motor starters
5.4 BU30-MS3 - BaseUnit with 24 V DC infeed

5.4.3 Technical specifications

Technical specifications of the BaseUnit with 24 V DC infeed

3RK1908-0AP00-0BP0
Product type designation BU30-MS3
Galvanic isolation
Galvanic isolation between backplane bus and Yes
supply voltage
Insulation tested with 2500 V AC
Rated operating voltage 24 V DC
Max. operating current 7 A (observe derating)
Rated insulation voltage in accordance with IEC 500 V
60947-1
Impulse withstand voltage/rated value Uimp accord- 6 kV
ing to IEC 60947-1
Operating voltage range 48 ... 500 V AC
Max. current-carrying capacity 32 A (observe derating)
Isolating function between the infeed terminals 6 kV
L1(L), L2 (N), L3 and motor feeder terminals T1,
T2, T3 for motor starters in parking position, or
removed motor starters: impulse withstand volt-
age/rated value Uimp according to IEC 60947-1
Wiring
Push-in Required tools for releasing: Standard screwdriv-
er size 1 (SZF1 - 0.6x3.5)
Dimensions
Width 30 mm
Height 215 mm
Weight, approx. 152 g

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
Manual, 02/2018, A5E03727049-AJ 99
BaseUnits for motor starters
5.5 BU30-MS4 - BaseUnit without infeed

5.5 BU30-MS4 - BaseUnit without infeed

5.5.1 Product overview

Article number
3RK1908-0AP00-0DP0

View

Figure 5-7 BaseUnit without infeed

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
100 Manual, 02/2018, A5E03727049-AJ
BaseUnits for motor starters
5.5 BU30-MS4 - BaseUnit without infeed

Properties
● BaseUnit suitable for all fail-safe and non-fail-safe SIMATIC ET 200SP High Feature
motor starters
● No new potential groups are opened with this BaseUnit.
● The potential group (24 V DC) is looped through.
● The infeed group (500 V AC) is looped through.
● Connection method using push-in terminals
● The touch protection cover for the infeed bus is not included in the scope of delivery.
● The fail-safe input F-DI of the fail-safe motor starter is connected to the power bus.

5.5.2 Connection

Pin assignment

Pin assignment for BaseUnit without infeed


Terminal Descriptions
T1, T2, T3, PE Motor feeder

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
Manual, 02/2018, A5E03727049-AJ 101
BaseUnits for motor starters
5.5 BU30-MS4 - BaseUnit without infeed

Block diagram
The figure below shows the block diagram of the BaseUnit without infeed.

① Backplane bus
② Motor starter module
③ Connected busbars 24 V DC, M
④ Interrupted AUX bus
⑤ Connected busbars for the infeed system L1(L), L2(N), L3, PE
⑥ Terminal for protective ground PE
⑦ Terminal T3
⑧ Terminal T2
⑨ Terminal T1

Figure 5-8 Block diagram BaseUnit without infeed

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
102 Manual, 02/2018, A5E03727049-AJ
BaseUnits for motor starters
5.5 BU30-MS4 - BaseUnit without infeed

5.5.3 Technical specifications

Technical specifications of BaseUnit without infeed

3RK1908-0AP00-0DP0
Product type designation BU30-MS4
Galvanic isolation
Galvanic isolation between backplane bus and Yes
supply voltage
Insulation tested with 2500 V AC
Rated operating voltage 24 V DC
Max. operating current 7 A (observe derating)
Rated insulation voltage in accordance with IEC 500 V
60947-1
Impulse withstand voltage/rated value Uimp accord- 6 kV
ing to IEC 60947-1
Operating voltage range 48 ... 500 V AC
Max. current-carrying capacity 32 A (observe derating)
Isolating function between the infeed terminals 6 kV
L1(L), L2 (N), L3 and motor feeder terminals T1,
T2, T3 for motor starters in parking position, or
removed motor starters: impulse withstand volt-
age/rated value Uimp according to IEC 60947-1
Wiring
Push-in Required tools for releasing: Standard screwdriv-
er size 1 (SZF1 - 0.6x3.5)
Dimensions
Width 30 mm
Height 215 mm
Weight, approx. 150 g

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
Manual, 02/2018, A5E03727049-AJ 103
BaseUnits for motor starters
5.6 BU30-MS5 BaseUnit with 500 V AC infeed and F-DI

5.6 BU30-MS5 BaseUnit with 500 V AC infeed and F-DI

5.6.1 Product overview

Article number
3RK1908-0AP00-0EP0

View

Figure 5-9 BaseUnit with 500 V AC and F-DI

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
104 Manual, 02/2018, A5E03727049-AJ
BaseUnits for motor starters
5.6 BU30-MS5 BaseUnit with 500 V AC infeed and F-DI

Properties
● BaseUnit suitable for all fail-safe SIMATIC ET 200SP High Feature motor starters
● The BaseUnit takes over the potential group (P1, P2) from the adjacent module on the
left.
● The BaseUnit opens a new supply group 500 V AC. The potential group (24 V DC) is
further continued
● The BaseUnit has an F-DI input terminal for fail-safe control signals of the motor starter.
This signal is not forwarded to neighboring motor starters.
● Connection method using push-in terminals
● The touch protection cover for the infeed bus is included in the scope of delivery.

Maximum configuration of the supply bus


The number of I/O modules that can be used per potential group depends on the following
factors:
1. Total power requirement of all I/O modules operated on this potential group
2. Total power requirement of all loads connected externally to this potential group
The total current calculated according to item 1. and item 2. must not exceed 7 A.

Properties of the F-DI input


The fail-safe digital input "F-DI" has the following properties:
● Use of interconnection type 1oo1 possible
● Sink input
● Input delay 10 ms
● Status display of the input F-DI at the motor starter module (green LED)

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
Manual, 02/2018, A5E03727049-AJ 105
BaseUnits for motor starters
5.6 BU30-MS5 BaseUnit with 500 V AC infeed and F-DI

5.6.2 Connection

Pin assignment

Pin assignment for BaseUnit with 500 V AC infeed and F-DI


Terminal Descriptions
T1, T2, T3, PE Motor feeder
F-DI, M F-DI: Connection of fail-safe signal M:
Reference potential of fail-safe signal
L1(L), L2(N), L3, PE Power supply
Assignment is determined by the motor starter.
You can find more information in the ET 200SP Motor Starter
(https://support.industry.siemens.com/cs/ww/en/view/109479973)
manual.

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
106 Manual, 02/2018, A5E03727049-AJ
BaseUnits for motor starters
5.6 BU30-MS5 BaseUnit with 500 V AC infeed and F-DI

Block diagram
The figure below shows the two-phase connection with 500 V AC infeed and F-DI:

① Backplane bus
② Motor starter module
③ Connected busbars 24 V DC, M
④ Interrupted AUX bus
⑤ Safety input F-DI (P24/M)
⑥ Interrupted busbars for the infeed system L1(L), L2(N), L3, PE
⑦ Infeed terminal for protective ground PE
⑧ Infeed terminal L3
⑨ Infeed terminal L2(N)
⑩ Infeed terminal L1(L)
⑪ Terminal for protective ground PE
⑫ Terminal T3
⑬ Terminal T2
⑭ Terminal T1

Figure 5-10 BaseUnit block diagram with 500 V AC infeed and fail-safe input

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
Manual, 02/2018, A5E03727049-AJ 107
BaseUnits for motor starters
5.6 BU30-MS5 BaseUnit with 500 V AC infeed and F-DI

5.6.3 Technical specifications

Technical specifications of the BaseUnit with 500 V AC infeed and F-DI

3RK1908-0AP00-0EP0
Product type designation BU30-MS5
Galvanic isolation
Galvanic isolation between backplane bus and Yes
supply voltage
Insulation tested with 2500 V AC
Rated operating voltage 24 V DC
Max. operating current 7 A (observe derating)
Galvanic isolation between fail-safe digital input Yes
and supply voltage
Rated insulation voltage in accordance with IEC 500 V
60947-1
Impulse withstand voltage/rated value Uimp accord- 6 kV
ing to IEC 60947-1
Operating voltage range 48 ... 500 V AC
Max. current-carrying capacity 32 A (observe derating)
Isolating function between the infeed terminals 6 kV
L1(L), L2 (N), L3 and motor feeder terminals T1,
T2, T3 for motor starters in parking position, or
removed motor starters: impulse withstand volt-
age/rated value Uimp according to IEC 60947-1
Wiring
Push-in Required tools for releasing: Standard screwdriv-
er size 1 (SZF1 - 0.6x3.5)
Dimensions
Width 30 mm
Height 215 mm
Weight, approx. 152 g

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
108 Manual, 02/2018, A5E03727049-AJ
BaseUnits for motor starters
5.7 BU30-MS6 BaseUnit without infeed and with F-DI

5.7 BU30-MS6 BaseUnit without infeed and with F-DI

5.7.1 Product overview

Article number
3RK1908-0AP00-0FP0

View

Figure 5-11 BaseUnit without 500 V AC infeed, with F-DI

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
Manual, 02/2018, A5E03727049-AJ 109
BaseUnits for motor starters
5.7 BU30-MS6 BaseUnit without infeed and with F-DI

Properties
● BaseUnit suitable for all fail-safe SIMATIC ET 200SP High Feature motor starters
● The BaseUnit takes over the potential group (P1, P2) from the adjacent module on the
left.
● This BaseUnit handles the potential group/infeed bus (500 V AC) of the left-hand
BaseUnit and loops this through.
● The BaseUnit has an F-DI input terminal for fail-safe control signals of the motor starter.
This signal is not forwarded to neighboring motor starters.
● Connection method using push-in terminals
● The touch protection cover for the infeed bus is not included in the scope of delivery.

Properties of the F-DI input


The fail-safe digital input "F-DI" has the following properties:
● Use of interconnection type 1oo1 possible
● Sink input
● Input delay 10 ms
● Status display of the input F-DI at the motor starter module (green LED)

5.7.2 Connection

Pin assignment

Pin assignment for BaseUnit with 24 V DC infeed


Terminal Descriptions
T1, T2, T3, PE Motor feeder
F-DI, M F-DI: Connection of fail-safe signal
M: Reference potential of fail-safe signal

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
110 Manual, 02/2018, A5E03727049-AJ
BaseUnits for motor starters
5.7 BU30-MS6 BaseUnit without infeed and with F-DI

Block diagram
The following figure shows the block diagram for the BaseUnit without infeed, but with fail-
safe input:

① Backplane bus
② Motor starter module
③ Connected busbars 24 V DC, M
④ Interrupted AUX bus
⑤ Safety input F-DI (P24/M)
⑥ Connected busbars infeed system L1, L2, L3, PE
⑦ Terminal for protective ground PE
⑧ Terminal T3
⑨ Terminal T2
⑩ Terminal T1

Figure 5-12 Block diagram BaseUnit without infeed, with fail-safe input

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
Manual, 02/2018, A5E03727049-AJ 111
BaseUnits for motor starters
5.7 BU30-MS6 BaseUnit without infeed and with F-DI

5.7.3 Technical specifications

Technical specifications of BaseUnit without infeed, with F-DI

3RK1908-0AP00-0FP0
Product type designation BU30-MS6
Galvanic isolation
Galvanic isolation between backplane bus and Yes
supply voltage
Insulation tested with 2500 V AC
Rated operating voltage 24 V DC
Max. operating current 7 A (observe derating)
Rated insulation voltage in accordance with IEC 500 V
60947-1
Galvanic isolation between fail-safe digital input Yes
and supply voltage
Impulse withstand voltage/rated value Uimp accord- 6 kV
ing to IEC 60947-1
Operating voltage range 48 ... 500 V AC
Max. current-carrying capacity 32 A (observe derating)
Isolating function between the infeed terminals 6 kV
L1(L), L2 (N), L3 and motor feeder terminals T1,
T2, T3 for motor starters in parking position, or
removed motor starters: impulse withstand volt-
age/rated value Uimp according to IEC 60947-1
Wiring
Push-in Required tools for releasing: Standard screwdriv-
er size 1 (SZF1 - 0.6x3.5)
Dimensions
Width 30 mm
Height 215 mm
Weight, approx. 152 g

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
112 Manual, 02/2018, A5E03727049-AJ
Potential distributor modules 6
6.1 Introduction

Properties of potential distributor modules


A potential distributor module (PotDis module) consists of a potential distributor BaseUnit
(PotDis-BU) and a potential distributor terminal block (PotDis-TB) installed on top of it.
A system-integrated potential distribution is possible with the various PotDis-BUs and
PotDis-TBs.
You can place potential distributor modules at any location with the ET 200SP distributed I/O
system. In doing so, you must observe the same design rules that apply to the design of a
potential group from the BaseUnits for I/O modules. The following information is particularly
important:
● The potential groups opened with a light-colored PotDis-BU must contain no I/O modules.
You can integrate any dark-colored PotDis-BUs into I/O module potential groups provided
these are based on SELV/PELV supply.
● If you do not need the additional terminals of the PotDis-TB in a potential distributor
module, replace the PotDis-TB with a BU-Cover.
● You may only connect one potential group within a combination of PotDis-BU and PotDis-
TB.
● Only SELV/PELV potentials are permitted on PotDis-BUs. Separate different SELV/PELV
potential groups using light-colored PotDis-BUs.
● With potential distributor modules you may only connect to the PotDis-TB versions BR-W
and n.c.-G potential, which exceed the voltage level of SELV/PELV.
● PotDis terminals are not directly configurable as PotDis via GSD/GSDML. When
configuring with GSD, always use an empty module; with GSDML, integrate a free space.
Potential distributor modules are configurable with STEP 7/STEP 7 TIA Portal. Individual
versions are listed in the following table:

Engineering with version/HSP


STEP 7 TIA Portal
• Configurable as of version HSP0241 up to V13 SP1 Update 8
HSP0241 up to V14
• Configurable as of version
HSP0241 up to V14 SP1 Update 5
• Configurable as of version HSP0241 up to V15 Update 1
• Configurable as of version
STEP 7
• Configurable as of version HSP0293 up to V5.5 SP4

You can find additional information on the use of the potential distributor modules in the
ET 200SP Distributed I/O System
(http://support.automation.siemens.com/WW/view/en/58649293) system manual.

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
Manual, 02/2018, A5E03727049-AJ 113
Potential distributor modules
6.2 PotDis-BU type P1, light-colored version

6.2 PotDis-BU type P1, light-colored version

6.2.1 Short designation

Short designation
Light-colored version with 16 terminals to P1 + 2 supply terminals P1/P2.
Short designation: PotDis-BU-P1/D-R.
D stands for a new potential group, which means P1, P2, AUX separated to the left,
R stands for red spring release.

6.2.2 Product overview

Delivery options (packing unit VPE)


6ES7193-6UP00-0DP1 (VPE: 1 unit)

View

Figure 6-1 PotDis-BU type P1, light-colored version

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
114 Manual, 02/2018, A5E03727049-AJ
Potential distributor modules
6.2 PotDis-BU type P1, light-colored version

Properties
● BaseUnit suitable for all PotDis terminal blocks of the type "P1/P2/N0/P0". Can be
recognized by the laser inscription on the front and/or the last two digits of the article
number.
– Supply voltage (terminal P1, P2) up to DC 48 V/10 A
– Current carrying capacity per terminal: Max. 10 A
● BaseUnit opens up a new PotDis potential group. The self-assembling voltage buses P1,
P2 and the AUX busbar are disconnected from the adjacent module on the left (BaseUnit,
CPU, interface module).

NOTICE
Opening a potential group for I/O modules is not permitted with the BaseUnit PotDis-
BU-P1/D-R.
The BaseUnit PotDis-BU-P1/D-R opens a new potential group only for the potential
distributor modules. Opening a potential group for I/O modules is not permitted with the
BaseUnit PotDis-BU-P1/D-R.

● 18 terminals
– 17 red terminals (P1)
– 1 blue terminal (P2)
● 36 terminals (with PotDis-TB)
● Connection system in the form of push-in terminals

6.2.3 Connecting

Pin assignment

Pin assignment for BaseUnit PotDis-BU type P1, light-colored version


Terminal Explanation
P1 Rated supply voltage up to 48 V DC with max. 10 A (17 red terminals)
P2 Ground (1 terminal)

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
Manual, 02/2018, A5E03727049-AJ 115
Potential distributor modules
6.2 PotDis-BU type P1, light-colored version

Block diagram

① Backplane bus
② PotDis-TB terminal block
③ Terminals with connection to the supply voltage P1
④ Disconnected voltage bus with connection to the terminals for supply
⑤ Interrupted AUX busbar

Figure 6-2 Block diagram of the PotDis-BU type P1, light-colored version

6.2.4 Technical specifications

Technical specifications of the BaseUnit PotDis-BU type P1, light-colored version

Article number 6ES7193-6UP00-0DP1


General information
Product type designation PotDis BU type P1, light version, PU 1
Supply voltage
Rated value (DC)
• For P1 and P2 bus 48 V; max.
• for process terminals 48 V; max.
external protection for power supply lines Yes; 10 A miniature circuit breaker with type B or
C tripping characteristic for the respective rated
supply voltage
Current carrying capacity
For P1 and P2 bus, max. 10 A
For process terminals, max. 10 A
Hardware configuration
Formation of potential groups
• New potential group Yes

• Potential group continued from the left No

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
116 Manual, 02/2018, A5E03727049-AJ
Potential distributor modules
6.2 PotDis-BU type P1, light-colored version

Article number 6ES7193-6UP00-0DP1


Potential separation
between backplane bus and supply voltage Yes
Isolation
Isolation tested with 3 250 V DC
Ambient conditions
Ambient temperature during operation
• horizontal installation, min. 0 °C; No condensation

• horizontal installation, max. 60 °C

• vertical installation, min. 0 °C; No condensation

• vertical installation, max. 50 °C

• Vertical installation, min. 0 °C; No condensation

• Vertical installation, max. 50 °C

• Horizontal installation, min. 0 °C; No condensation

• Horizontal installation, max. 50 °C

Altitude during operation relating to sea level


• Ambient air temperature-barometric pres- On request: Ambient temperatures lower than 0
sure-altitude °C (without condensation) and/or installation
altitudes greater than 2 000 m
Accessories
Color coding labels
• for process terminals CC62

Connection method
Terminals
• Terminal type Push-in terminal

• Conductor cross-section, min. 0.14 mm²

• Conductor cross-section, max. 2.5 mm²

• Number of terminals with connection to P1 17 terminals to P1, 1 terminal to P2


and P2 bus
Dimensions
Width 15 mm
Height 117 mm
Depth 35 mm
Weights
Weight, approx. 40 g

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
Manual, 02/2018, A5E03727049-AJ 117
Potential distributor modules
6.3 PotDis-BU type P1, dark-colored version

6.3 PotDis-BU type P1, dark-colored version

Short designation
Dark-colored version with 16 terminals to P1 + 2 supply terminals P1/P2.
Short designation: PotDis-BU-P1/B-R.
B stands for bridged potential group, which means P1, P2, AUX bridged to the left,
R stands for red spring release.

6.3.1 Product overview

Delivery options (packing unit VPE)


6ES7193-6UP00-0BP1 (VPE: 1 unit)

View

Figure 6-3 PotDis-BU type P1, dark-colored version

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
118 Manual, 02/2018, A5E03727049-AJ
Potential distributor modules
6.3 PotDis-BU type P1, dark-colored version

Properties
● BaseUnit suitable for all PotDis terminal blocks of the type "P1/P2/N0/P0". Can be
recognized by the laser inscription on the front and/or the last two digits of the article
number.
– Current carrying capacity per terminal: Max. 10 A
● BaseUnit further conducts the potential group. The self-assembling voltage buses P1, P2
and the AUX busbar are connected to the adjacent module on the left (BaseUnit).
● 18 terminals
– 17 red terminals (P1)
– 1 blue terminal (P2)
● 36 terminals (with PotDis-TB)
● Connection system in the form of push-in terminals

6.3.2 Connecting

Pin assignment

Pin assignment for BaseUnit PotDis-BU type P1, dark-colored version


Terminal Explanation
P1 Rated supply voltage up to 48 V DC with max. 10 A (17 red terminals)
P2 Ground (1 terminal)

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
Manual, 02/2018, A5E03727049-AJ 119
Potential distributor modules
6.3 PotDis-BU type P1, dark-colored version

Block diagram

① Backplane bus
② PotDis-TB terminal block
③ Terminals with connection to the supply voltage P1
④ Connected voltage bus with connection to the terminals
⑤ Connected AUX busbar

Figure 6-4 Block diagram of the PotDis-BU type P1, dark-colored version

6.3.3 Technical specifications

Technical specifications of the BaseUnit PotDis-BU type P1, dark-colored version

Article number 6ES7193-6UP00-0BP1


General information
Product type designation PotDis BU type P1, dark version, PU 1
Supply voltage
Rated value (DC)
• For P1 and P2 bus 48 V; max.

• for process terminals 48 V; max.

external protection for power supply lines Yes; 10 A miniature circuit breaker with type B or
C tripping characteristic for the respective rated
supply voltage
Current carrying capacity
For P1 and P2 bus, max. 10 A
For process terminals, max. 10 A

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
120 Manual, 02/2018, A5E03727049-AJ
Potential distributor modules
6.3 PotDis-BU type P1, dark-colored version

Article number 6ES7193-6UP00-0BP1


Hardware configuration
Formation of potential groups
• New potential group No

• Potential group continued from the left Yes

Potential separation
between backplane bus and supply voltage Yes
Isolation
Isolation tested with 3 250 V DC
Ambient conditions
Ambient temperature during operation
• horizontal installation, min. 0 °C; No condensation

• horizontal installation, max. 60 °C

• vertical installation, min. 0 °C; No condensation

• vertical installation, max. 50 °C

• Vertical installation, min. 0 °C; No condensation

• Vertical installation, max. 50 °C

• Horizontal installation, min. 0 °C; No condensation

• Horizontal installation, max. 50 °C

Altitude during operation relating to sea level


• Ambient air temperature-barometric pres- On request: Ambient temperatures lower than 0
sure-altitude °C (without condensation) and/or installation
altitudes greater than 2 000 m
Accessories
Color coding labels
• for process terminals CC62

Connection method
Terminals
• Terminal type Push-in terminal

• Conductor cross-section, min. 0.14 mm²

• Conductor cross-section, max. 2.5 mm²

• Number of terminals with connection to P1 17 terminals to P1, 1 terminal to P2


and P2 bus
Dimensions
Width 15 mm
Height 117 mm
Depth 35 mm
Weights
Weight, approx. 40 g

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
Manual, 02/2018, A5E03727049-AJ 121
Potential distributor modules
6.4 PotDis-BU type P2, light-colored version

6.4 PotDis-BU type P2, light-colored version

6.4.1 Short designation

Short designation
Light-colored version with 16 terminals to P2 + 2 supply terminals P1/P2.
Short designation: PotDis-BU-P2/D-B.
D stands for a new potential group, which means P1, P2, AUX separated to the left,
B stands for blue spring release.

6.4.2 Product overview

Delivery options (packing unit VPE)


6ES7193-6UP00-0DP2 (VPE: 1 unit)

View

Figure 6-5 PotDis-BU type P2, light-colored version

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
122 Manual, 02/2018, A5E03727049-AJ
Potential distributor modules
6.4 PotDis-BU type P2, light-colored version

Properties
● BaseUnit suitable for all PotDis terminal blocks of the type "P1/P2/N0/P0". Can be
recognized by the laser inscription on the front and/or the last two digits of the article
number.
– Supply voltage (terminal P1, P2) up to DC 48 V/10 A
– Current carrying capacity per terminal: Max. 10 A
● BaseUnit opens up a new PotDis potential group. The self-assembling voltage buses P1,
P2 and the AUX busbar are disconnected from the adjacent module on the left (BaseUnit,
CPU, interface module).

NOTICE
Opening a potential group for I/O modules is not permitted with the BaseUnit PotDis-
BU-P2/D-B.
The BaseUnit PotDis-BU-P2/D-B opens a new potential group only for the potential
distributor modules. Opening a potential group for I/O modules is not permitted with the
BaseUnit PotDis-BU-P2/D-B.

● 18 terminals
– 1 red terminal (P1)
– 17 blue terminals (P2)
● 36 terminals (with PotDis-TB)
● Connection system in the form of push-in terminals

6.4.3 Connecting

Pin assignment

Pin assignment for PotDis-BU type P2, light-colored version


Terminal Explanation
P1 Rated supply voltage up to 48 V DC with max. 10 A (1 terminal)
P2 Ground (17 terminals)

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
Manual, 02/2018, A5E03727049-AJ 123
Potential distributor modules
6.4 PotDis-BU type P2, light-colored version

Block diagram

① Backplane bus
② PotDis-TB terminal block
③ Terminals with connection to ground P2
④ Disconnected voltage bus with connection to the terminals for supply
⑤ Interrupted AUX busbar

Figure 6-6 Block diagram of the PotDis-BU type P2, light-colored version

6.4.4 Technical specifications

Technical specifications of the BaseUnit PotDis-BU type P2, light-colored version

Article number 6ES7193-6UP00-0DP2


General information
Product type designation PotDis BU type P2, light version, PU 1
Supply voltage
Rated value (DC)
• For P1 and P2 bus 48 V; max.

• for process terminals 48 V; max.

external protection for power supply lines Yes; 10 A miniature circuit breaker with type B or
C tripping characteristic for the respective rated
supply voltage
Current carrying capacity
For P1 and P2 bus, max. 10 A
For process terminals, max. 10 A

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
124 Manual, 02/2018, A5E03727049-AJ
Potential distributor modules
6.4 PotDis-BU type P2, light-colored version

Article number 6ES7193-6UP00-0DP2


Hardware configuration
Formation of potential groups
• New potential group No

• Potential group continued from the left Yes

Potential separation
between backplane bus and supply voltage Yes
Isolation
Isolation tested with 3 250 V DC
Ambient conditions
Ambient temperature during operation
• horizontal installation, min. 0 °C; No condensation

• horizontal installation, max. 60 °C

• vertical installation, min. 0 °C; No condensation

• vertical installation, max. 50 °C

• Vertical installation, min. 0 °C; No condensation

• Vertical installation, max. 50 °C

• Horizontal installation, min. 0 °C; No condensation

• Horizontal installation, max. 50 °C

Altitude during operation relating to sea level


• Ambient air temperature-barometric pres- On request: Ambient temperatures lower than 0
sure-altitude °C (without condensation) and/or installation
altitudes greater than 2 000 m
Accessories
Color coding labels
• for process terminals CC63

Connection method
Terminals
• Terminal type Push-in terminal

• Conductor cross-section, min. 0.14 mm²

• Conductor cross-section, max. 2.5 mm²

• Number of terminals with connection to P1 18; 17 terminals to P2, 1 terminal to P1


and P2 bus
Dimensions
Width 15 mm
Height 117 mm
Depth 35 mm
Weights
Weight, approx. 40 g

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
Manual, 02/2018, A5E03727049-AJ 125
Potential distributor modules
6.5 PotDis-BU type P2, dark-colored version

6.5 PotDis-BU type P2, dark-colored version

6.5.1 Short designation

Short designation
Dark-colored version with 16 terminals to P2 + 2 supply terminals P1/P2.
Short designation: PotDis-BU-P2/B-B.
B stands for bridged potential group, which means P1, P2, AUX bridged to the left,
B stands for blue spring release.

6.5.2 Product overview

Delivery options (packing unit VPE)


6ES7193-6UP00-0BP2 (VPE: 1 unit)

View

Figure 6-7 PotDis-BU type P2, dark-colored version

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
126 Manual, 02/2018, A5E03727049-AJ
Potential distributor modules
6.5 PotDis-BU type P2, dark-colored version

Properties
● BaseUnit suitable for all PotDis terminal blocks of the type "P1/P2/N0/P0". Can be
recognized by the laser inscription on the front and/or the last two digits of the article
number.
– Current carrying capacity per terminal: Max. 10 A
● BaseUnit further conducts the potential group. The self-assembling voltage buses P1, P2
and the AUX busbar are connected to the adjacent module on the left (BaseUnit).
● 18 terminals
– 1 red terminal (P1)
– 17 blue terminals (P2)
● 36 terminals (with PotDis-TB)
● Connection system in the form of push-in terminals

6.5.3 Connecting

Pin assignment

Pin assignment for PotDis-BU type P2, dark-colored version


Terminal Explanation
P1 Rated supply voltage up to 48 V DC with max. 10 A (1 terminal)
P2 Ground (17 terminals)

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
Manual, 02/2018, A5E03727049-AJ 127
Potential distributor modules
6.5 PotDis-BU type P2, dark-colored version

Block diagram

① Backplane bus
② PotDis-TB terminal block
③ Terminals with connection to ground P2
④ Connected voltage bus with connection to the terminals
⑤ Connected AUX busbar

Figure 6-8 Block diagram of the PotDis-BU type P2, dark-colored version

6.5.4 Technical specifications

Technical specifications of the BaseUnit PotDis-BU type P2, dark-colored version

Article number 6ES7193-6UP00-0BP2


General information
Product type designation PotDis BU type P2, dark version, PU 1
Supply voltage
Rated value (DC)
• For P1 and P2 bus 48 V; max.

• for process terminals 48 V; max.

external protection for power supply lines Yes; 10 A miniature circuit breaker with type B or
C tripping characteristic for the respective rated
supply voltage
Current carrying capacity
For P1 and P2 bus, max. 10 A
For process terminals, max. 10 A

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
128 Manual, 02/2018, A5E03727049-AJ
Potential distributor modules
6.5 PotDis-BU type P2, dark-colored version

Article number 6ES7193-6UP00-0BP2


Hardware configuration
Formation of potential groups
• New potential group No

• Potential group continued from the left Yes

Potential separation
between backplane bus and supply voltage Yes
Isolation
Isolation tested with 3 250 V DC
Ambient conditions
Ambient temperature during operation
• horizontal installation, min. 0 °C; No condensation

• horizontal installation, max. 60 °C

• vertical installation, min. 0 °C; No condensation

• vertical installation, max. 50 °C

• Vertical installation, min. 0 °C; No condensation

• Vertical installation, max. 50 °C

• Horizontal installation, min. 0 °C; No condensation

• Horizontal installation, max. 50 °C

Altitude during operation relating to sea level


• Ambient air temperature-barometric pres- On request: Ambient temperatures lower than 0
sure-altitude °C (without condensation) and/or installation
altitudes greater than 2 000 m
Accessories
Color coding labels
• for process terminals CC63

Connection method
Terminals
• Terminal type Push-in terminal

• Conductor cross-section, min. 0.14 mm²

• Conductor cross-section, max. 2.5 mm²

• Number of terminals with connection to P1 18; 17 terminals to P2, 1 terminal to P1


and P2 bus
Dimensions
Width 15 mm
Height 117 mm
Depth 35 mm
Weights
Weight, approx. 40 g

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
Manual, 02/2018, A5E03727049-AJ 129
Potential distributor modules
6.6 PotDis-TB

6.6 PotDis-TB

6.6.1 Product overview

Article number
● PotDis-TB-P1-R terminal block: 6ES7193-6TP00-0TP1
● PotDis-TB-P2-B terminal block: 6ES7193-6TP00-0TP2
● PotDis-TB-n.c.-G terminal block: 6ES7193-6TP00-0TN0
● PotDis-TB-BR-W terminal block: 6ES7193-6TP00-0TP0

View

① PotDis-TB-P1-R
② PotDis-TB-P2-B
③ PotDis-TB-n.c.-G
④ PotDis-TB-BR-W

Figure 6-9 PotDis terminal blocks

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
130 Manual, 02/2018, A5E03727049-AJ
Potential distributor modules
6.6 PotDis-TB

Properties
● Terminal blocks matching all BaseUnits PotDis-BU
– Current carrying capacity per terminal: Max. 10 A
● 18 terminals
– PotDis-TB-P1-R terminal block: Red terminals with connection to the supply voltage
P1 of the BaseUnit PotDis-BU
– PotDis-TB-P2-B terminal block: Blue terminals with connection to ground P2 of the
BaseUnit PotDis-BU
– PotDis-TB-n.c.-G terminal block: Gray (internal not connected) terminals without
connection to the BaseUnit PotDis-BU

NOTICE
Mixed connection of direct current or alternating current (DC/AC) is not permitted on
the PotDis-TB-n.c-G
Connect direct currents up to 48 V or alternating currents up to 230 V to the terminals
of the PotDis-TB-n.c.-G. A mixed connection of both types of voltages (DC/AC) is not
permitted at the terminals of the PotDis-TB-n.c.-G.

– PotDis-TB-BR-W terminal block: White (internal not connected) terminals without


connection to the BaseUnit-BU

NOTICE
Only PotDis-TB-BR may be used for protective conductors.
Check all protective conductors.
Check the required conductor cross-section for the respective plant unit before
commissioning of the plant (especially for motor starters).

● Connection system in the form of push-in terminals


● You can find the assignment of color-coded labels in the ET 200SP System Manual under
Accessories.

NOTICE
Use of color-coded labels
Before commissioning the system, check that the color-coded labels attached correspond
to the wired potential.

NOTICE
Voltages greater than SELV/PELV
Voltages greater than SELV/PELV are only permitted for the PO PotDis-TBs BR (bridged)
and NC (not connected). This applies equally to protective conductors.
No voltages greater than SELV/PELV are present on the terminals of the PotDis module
with connection to the P1/P2 rails.

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
Manual, 02/2018, A5E03727049-AJ 131
Potential distributor modules
6.6 PotDis-TB

6.6.2 Connecting

Pin assignment

Pin assignment for PotDis-TB terminal block


Terminal block Terminal Explanation
PotDis-TB-P1-R P1 Rated supply voltage up to 48 V DC with max. 10 A (18 red
terminals)
PotDis-TB-P2-B P2 Ground (18 blue terminals)
PotDis-TB-n.c.-G n c. Terminals can be used freely up to 230 V AC with max. 10 A
(not connected) (18 gray terminals).
If you connect voltage, it must belong to the same potential
group.
PotDis-TB-BR-W BR (bridged) Terminals for protective conductor connection or voltage bus
freely usable up to 230 V AC with max. 10 A (18 white termi-
nals)

Block diagram

① PotDis-TB-P1-R
② PotDis-TB-P2-B
③ PotDis-TB-n.c.-G
④ PotDis-TB-BR-W

Figure 6-10 PotDis-TB block diagram

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
132 Manual, 02/2018, A5E03727049-AJ
Potential distributor modules
6.6 PotDis-TB

6.6.3 Technical specifications

Technical specifications of the PotDis-TB-P1_R terminal block

Article number 6ES7193-6TP00-0TP1


General information
Product type designation PotDis TB P1-R, PU 1
Supply voltage
Rated value (DC)
• For P1 and P2 bus 48 V; max.

• for process terminals 48 V; max.

Rated value (AC)


• For P1 and P2 bus 240 V; max.

• for process terminals 240 V; max.

external protection for power supply lines Yes; 10 A miniature circuit breaker with type B or
C tripping characteristic for the respective rated
supply voltage
Current carrying capacity
up to 60 °C, max. 10 A
For P1 and P2 bus, max. 10 A
For AUX bus, max. 10 A
For process terminals, max. 10 A
Ambient conditions
Ambient temperature during operation
• horizontal installation, min. 0 °C; No condensation

• horizontal installation, max. 60 °C

• vertical installation, min. 0 °C; No condensation

• vertical installation, max. 50 °C

• Vertical installation, min. 0 °C; No condensation

• Vertical installation, max. 50 °C

• Horizontal installation, min. 0 °C; No condensation

• Horizontal installation, max. 50 °C

Altitude during operation relating to sea level


• Ambient air temperature-barometric pres- On request: Ambient temperatures lower than 0
sure-altitude °C (without condensation) and/or installation
altitudes greater than 2 000 m

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
Manual, 02/2018, A5E03727049-AJ 133
Potential distributor modules
6.6 PotDis-TB

Article number 6ES7193-6TP00-0TP1


Accessories
Color coding labels
• for process terminals CC12

Connection method
Terminals
• Terminal type Push-in terminal

• Conductor cross-section, min. 0.14 mm²; 0.2 mm² without wire end ferrule

• Conductor cross-section, max. 2.5 mm²; 1.5 mm² with wire end ferrule

• Number of process terminals to I/O module 16

• Number of terminals to AUX bus 0

• Number of add-on terminals 0

• Number of terminals with connection to P1 2


and P2 bus
Dimensions
Width 15 mm
Height 74 mm
Depth 34 mm
Weights
Weight, approx. 24 g

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
134 Manual, 02/2018, A5E03727049-AJ
Potential distributor modules
6.6 PotDis-TB

Technical specifications of the PotDis-TB-P2-B terminal block

Article number 6ES7193-6TP00-0TP2


General information
Product type designation PotDis TB P2-B, PU 1
Supply voltage
Rated value (DC)
• For P1 and P2 bus 48 V; max.

• for process terminals 48 V; max.

Rated value (AC)


• For P1 and P2 bus 240 V; max.

• for process terminals 240 V; max.

external protection for power supply lines Yes; 10 A miniature circuit breaker with type B or
C tripping characteristic for the respective rated
supply voltage
Current carrying capacity
up to 60 °C, max. 10 A
For P1 and P2 bus, max. 10 A
For AUX bus, max. 10 A
For process terminals, max. 10 A
Potential separation
between process terminals and supply voltage No
Ambient conditions
Ambient temperature during operation
• horizontal installation, min. 0 °C; No condensation

• horizontal installation, max. 60 °C

• vertical installation, min. 0 °C; No condensation

• vertical installation, max. 50 °C

• Vertical installation, min. 0 °C; No condensation

• Vertical installation, max. 50 °C

• Horizontal installation, min. 0 °C; No condensation

• Horizontal installation, max. 50 °C

Altitude during operation relating to sea level


• Ambient air temperature-barometric pres- On request: Ambient temperatures lower than 0
sure-altitude °C (without condensation) and/or installation
altitudes greater than 2 000 m

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
Manual, 02/2018, A5E03727049-AJ 135
Potential distributor modules
6.6 PotDis-TB

Article number 6ES7193-6TP00-0TP2


Accessories
Color coding labels
• for process terminals CC13

Connection method
Terminals
• Terminal type Push-in terminal

• Conductor cross-section, min. 0.14 mm²; 0.2 mm² without wire end ferrule

• Conductor cross-section, max. 2.5 mm²; 1.5 mm² with wire end ferrule

• Number of process terminals to I/O module 16

• Number of terminals to AUX bus 0

• Number of add-on terminals 0

• Number of terminals with connection to P1 2


and P2 bus
Dimensions
Width 15 mm
Height 74 mm
Depth 34 mm
Weights
Weight, approx. 24 g

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
136 Manual, 02/2018, A5E03727049-AJ
Potential distributor modules
6.6 PotDis-TB

Technical specifications of the PotDis-TB-n.c.-G

Article number 6ES7193-6TP00-0TN0


General information
Product type designation PotDis TB n.c. G, PU 1
Supply voltage
Rated value (DC)
• for process terminals 48 V; max.

Rated value (AC)


• for process terminals 240 V; max.

external protection for power supply lines Yes; 10 A miniature circuit breaker with type B or
C tripping characteristic for the respective rated
supply voltage
Current carrying capacity
up to 60 °C, max. 10 A
For P1 and P2 bus, max. 10 A
For AUX bus, max. 10 A
Potential separation
between process terminals and supply voltage Yes
Ambient conditions
Ambient temperature during operation
• horizontal installation, min. 0 °C; No condensation

• horizontal installation, max. 60 °C

• vertical installation, min. 0 °C; No condensation

• vertical installation, max. 50 °C

• Vertical installation, min. 0 °C; No condensation

• Vertical installation, max. 50 °C

• Horizontal installation, min. 0 °C; No condensation

• Horizontal installation, max. 50 °C

Altitude during operation relating to sea level


• Ambient air temperature-barometric pres- On request: Ambient temperatures lower than 0
sure-altitude °C (without condensation) and/or installation
altitudes greater than 2 000 m

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
Manual, 02/2018, A5E03727049-AJ 137
Potential distributor modules
6.6 PotDis-TB

Article number 6ES7193-6TP00-0TN0


Accessories
Color coding labels
• for process terminals CC10

Connection method
Terminals
• Terminal type Push-in terminal

• Conductor cross-section, min. 0.14 mm²; 0.2 mm² without wire end ferrule

• Conductor cross-section, max. 2.5 mm²; 1.5 mm² with wire end ferrule

• Number of process terminals to I/O module 16

• Number of terminals to AUX bus 0

• Number of add-on terminals 0

• Number of terminals with connection to P1 2


and P2 bus
Dimensions
Width 15 mm
Height 74 mm
Depth 34 mm
Weights
Weight, approx. 24 g

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
138 Manual, 02/2018, A5E03727049-AJ
Potential distributor modules
6.6 PotDis-TB

Technical specifications of the PotDis-TB-BR-W terminal block

Article number 6ES7193-6TP00-0TP0


General information
Product type designation PotDis TB BR-W, PU 1
Supply voltage
Rated value (DC)
• for process terminals 48 V; max.

Rated value (AC)


• for process terminals 240 V; max.

external protection for power supply lines Yes; 10 A miniature circuit breaker with type B or
C tripping characteristic for the respective rated
supply voltage
Current carrying capacity
up to 60 °C, max. 10 A
For P1 and P2 bus, max. 10 A
For AUX bus, max. 10 A
For process terminals, max. 10 A
Potential separation
between process terminals and supply voltage Yes
Ambient conditions
Ambient temperature during operation
• horizontal installation, min. 0 °C; No condensation

• horizontal installation, max. 60 °C

• vertical installation, min. 0 °C; No condensation

• vertical installation, max. 50 °C

• Vertical installation, min. 0 °C; No condensation

• Vertical installation, max. 50 °C

• Horizontal installation, min. 0 °C; No condensation

• Horizontal installation, max. 50 °C

Altitude during operation relating to sea level


• Ambient air temperature-barometric pres- On request: Ambient temperatures lower than 0
sure-altitude °C (without condensation) and/or installation
altitudes greater than 2 000 m

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
Manual, 02/2018, A5E03727049-AJ 139
Potential distributor modules
6.6 PotDis-TB

Article number 6ES7193-6TP00-0TP0


Accessories
Color coding labels
• for process terminals CC10

Connection method
Terminals
• Terminal type Push-in terminal

• Conductor cross-section, min. 0.14 mm²; 0.2 mm² without wire end ferrule

• Conductor cross-section, max. 2.5 mm²; 1.5 mm² with wire end ferrule

• Number of process terminals to I/O module 16

• Number of terminals to AUX bus 0

• Number of add-on terminals 0

• Number of terminals with connection to P1 2


and P2 bus
Dimensions
Width 15 mm
Height 74 mm
Depth 34 mm
Weights
Weight, approx. 24 g

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
140 Manual, 02/2018, A5E03727049-AJ
Dimension drawings of I/O modules A
Dimension drawing BU15-P16+A10+2D, BU15-P16+A10+2B, BU15-P16+A0+12D/T,
BU15-P16+A0+12B/T
The figure below shows the dimension drawing of the BU15-P16+A10+2D
with plugged-in I/O module as an example.

Figure A-1 Dimension drawing BU15-P16+A10+2D

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
Manual, 02/2018, A5E03727049-AJ 141
Dimension drawings of I/O modules

Dimension drawing BU15-P16+A0+2D, BU15-P16+A0+2B, BU15-P16+A0+2D/T,


BU15-P16+A0+2B/T
The figure below shows the dimension drawing of the BU15-P16+A0+2D with
plugged-in I/O module as an example.

Figure A-2 Dimension drawing BU15-P16+A0+2D

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
142 Manual, 02/2018, A5E03727049-AJ
Dimension drawings of I/O modules

Dimension drawing BU20-P6+A2+4D, BU20-P6+A2+4B, BU20-P12+A4+0B, BU20-P12+A0+0B,


BU20-P12+A0+4B, BU20-P8+A4+0B
The figure below shows the dimension drawing of the BU20-P12+A4+0B with
plugged-in I/O module as an example.

Figure A-3 Dimension drawing BU20-P12+A4+0B

Dimension drawing test probe for measurement tap


The figure below shows the dimension drawing of a suitable test probe for measurement tap
at the BaseUnit.

Figure A-4 Dimension drawing test probe

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
Manual, 02/2018, A5E03727049-AJ 143
Dimension drawings of motor starters B
Dimension drawing BU30-MS1, BU30-MS2, BU30-MS3, BU30-MS4, BU30-MS5, BU30-MS6
The figure below shows the dimension drawing of the BU30-MS-1 with plugged-in
motor starter module as an example.

Figure B-1 Dimension drawing BU30-MS1

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
144 Manual, 02/2018, A5E03727049-AJ
Dimension drawings of the potential distributor
modules 7
Dimension drawing
The figure below shows the dimension drawing of the PotDis-BU-P1/B-R with
plugged-in PotDis-TB-P1-R terminal block.

Figure 7-1 Dimension drawing of PotDis BU-P1/B-R with plugged-in terminal block

BaseUnits (6ES7193-6BP.../3RK1908-0AP00…)
Manual, 02/2018, A5E03727049-AJ 145