Coax Cable

Electrical Characteristics
Capacitance : 95pF/m
Impedance : 50Ω ±2Ω
Velocity of Propagation : 69.5%
Conductor DCR : 277.2Ω / km
Outer shield DCR : 20Ω / km
Max. Operating Frequency : 3,000MHz
Max. Operating Voltage : 1,200 RMS
Corona Extinction Voltage : 1,200Vrms
Voltage withstand : 2,000Vrms
Spark Test : 2,000Vrms
Operating Temperature Range : -55°C to +200°C

Construction
Diameter
Item Material
Inch mm
Inner conductor Silver plated copper clad steel 7 / 0.0067 ±0.001 7 / 0.17 ±0.02
Dielectric PTFE 0.06 ±0.003 1.52 ±0.08
Shield 95% Silver plated copper braid 0.078 ±0.003 1.98 ±0.08
Jacket FEP 0.098 ±0.004 2.49 ±0.1

Attenuation (at 20°C)


Frequency Maximum Attenuation Maximum Attenuation
(MHz) (dB / 100 ft) (dB / 100 m)
10 2.7 8.9
50 5.6 18.4
100 8.3 27.2
200 11 36.1
400 16.7 54.8
700 22.8 74.8
900 26.3 86.3
1,000 28.6 93.8
3,000 53.3 174.9
Part Number Table
Description Part Number
Cable, Coax, RG316, 100m RG316

Important Notice : This data sheet and its contents (the “Information”) belong to the members of the AVNET group of companies (the “Group”) or are licensed to it. No licence is granted for
the use of it other than for information purposes in connection with the products to which it relates. No licence of any intellectual property rights is granted. The Information is subject to change
without notice and replaces all data sheets previously supplied. The Information supplied is believed to be accurate but the Group assumes no responsibility for its accuracy or completeness,
any error in or omission from it or for any use made of it. Users of this data sheet should check for themselves the Information and the suitability of the products for their purpose and not make
any assumptions based on information included or omitted. Liability for loss or damage resulting from any reliance on the Information or use of it (including liability resulting from negligence or
where the Group was aware of the possibility of such loss or damage arising) is excluded. This will not operate to limit or restrict the Group’s liability for death or personal injury resulting from its
negligence. Multicomp Pro is the registered trademark of Premier Farnell Limited 2019.

Newark.com/multicomp-pro
Farnell.com/multicomp-pro
Element14.com/multicomp-pro

Page <1> 09/11/20 V1.0

You might also like