Data Sheet: Coaxial Cable Sucoform - 86 - CT
Data Sheet: Coaxial Cable Sucoform - 86 - CT
Data Sheet: Coaxial Cable Sucoform - 86 - CT
Coaxial Cable
SUCOFORM_86_CT
Description
SUCOFORM, the handformable microwave cable
Technical Data
Construction
Material Detail Diameter
Outer conductor Copper, Tin plated Tin soaked braid, 100% 2.15 mm
Electrical Data
Impedance 50 Ω +/- 2
Operating Frequency 20 GHz
Capacitance 83.5 pF/m
Velocity of signal propagation 80 %
Signal delay 4.2 ns/m
Insulation resistance ≥ 1 x 108 MΩm
Min. screening effectiveness ≥ 100 dB (up to 18 GHz)
Max. operating voltage ≤ 1.5 kVrms (at sea level)
Test voltage 3 kVrms (50 Hz/1 min)
Phase vs Temperature -55°C... + 125°C 250 ppm
Phase vs Bending 5 °/GHz
Mechanical Data
Weight 1.5 kg/100 m
Min. bending radius static 6 mm
repeated (for ≤ 50 bendings) 20 mm
Environmental Data
Temperature range -65 °C... +200 °C
Installation temperature -20 °C... +60 °C
2011/95/EC (RoHS) compliant
Additional Information
Ordering Information
Order as SUCOFORM_86_CT
Remarks
(For details refer to the HUBER+SUHNER MICROWAVE CABLES AND ASSEMBLIES GENERAL CATALOGUE or contact your nearest HUBER+SUHNER partner)
Suitable Connectors
Cable group U99 Customer Specific
Document: DOC-0000761885 A / PDO E.00 / date of publication: 13.09.2016 07:48:18 / uncontrolled copy Page 1/2
Data Sheet
Coaxial Cable
SUCOFORM_86_CT
Matrix typical Attenuation [ formula: (a*f^0.5 + b*f) ] and maximum Power CW [ formula: (p/f^0.5) ]
Coefficients:
a = 0.5476 b = 0.0477 fmax = 20 P at 1GHz = 165
HUBER+SUHNER is certified according to ISO 9001, ISO 14001, AS/EN9100, ISO/TS 16949 and IRIS. www.hubersuhner.com
Waiver: Fact and figures herein are for information only and do not represent any warranty of any kind.
Document: DOC-0000761885 A / PDO E.00 / date of publication: 13.09.2016 07:48:18 / uncontrolled copy Page 2/2