Data Sheet

Coaxial Cable
SUCOFORM_86_CT

Description
SUCOFORM, the handformable microwave cable

Technical Data
Construction
Material Detail Diameter

Centre conductor Copper, Silver plated Wire 0.62 mm

Dielectric Low density fluorine polymer 1.74 mm

Outer conductor Copper, Tin plated Tin soaked braid, 100% 2.15 mm

Print: HUBER+SUHNER SUCOFORM 86 CT 50 Ohm (PA no.)

Electrical Data
Impedance 50 Ω +/- 2
Operating Frequency 20 GHz
Capacitance 83.5 pF/m
Velocity of signal propagation 80 %
Signal delay 4.2 ns/m
Insulation resistance ≥ 1 x 108 MΩm
Min. screening effectiveness ≥ 100 dB (up to 18 GHz)
Max. operating voltage ≤ 1.5 kVrms (at sea level)
Test voltage 3 kVrms (50 Hz/1 min)
Phase vs Temperature -55°C... + 125°C 250 ppm
Phase vs Bending 5 °/GHz

Mechanical Data
Weight 1.5 kg/100 m
Min. bending radius static 6 mm
repeated (for ≤ 50 bendings) 20 mm

Environmental Data
Temperature range -65 °C... +200 °C
Installation temperature -20 °C... +60 °C
2011/95/EC (RoHS) compliant

Additional Information
Ordering Information
Order as SUCOFORM_86_CT

Remarks
(For details refer to the HUBER+SUHNER MICROWAVE CABLES AND ASSEMBLIES GENERAL CATALOGUE or contact your nearest HUBER+SUHNER partner)
Suitable Connectors
Cable group U99 Customer Specific

Document: DOC-0000761885 A / PDO E.00 / date of publication: 13.09.2016 07:48:18 / uncontrolled copy Page 1/2
Data Sheet
Coaxial Cable
SUCOFORM_86_CT
Matrix typical Attenuation [ formula: (a*f^0.5 + b*f) ] and maximum Power CW [ formula: (p/f^0.5) ]
Coefficients:
a = 0.5476 b = 0.0477 fmax = 20 P at 1GHz = 165

Frequency Nom. attenuation Nom. attenuation Max. CW power

(GHz) (dB / m) (dB / ft) (watt)

sea level 25° C sea level 25° C sea level 40° C


ambient ambient ambient
temperature temperature temperature

1.0 0.6 0.181 165

2.0 0.87 0.265 117

3.0 1.09 0.333 95

4.0 1.29 0.392 83

5.0 1.46 0.446 74

6.0 1.63 0.496 67

7.0 1.78 0.543 62

8.0 1.93 0.588 58

9.0 2.07 0.632 55

10.0 2.21 0.673 52

11.0 2.34 0.713 50

12.0 2.47 0.753 48

13.0 2.59 0.791 46

14.0 2.72 0.828 44

15.0 2.84 0.864 43

16.0 2.95 0.900 41

17.0 3.07 0.935 40

18.0 3.18 0.970 39

19.0 3.29 1.004 38

20.0 3.4 1.037 37

HUBER+SUHNER is certified according to ISO 9001, ISO 14001, AS/EN9100, ISO/TS 16949 and IRIS. www.hubersuhner.com
Waiver: Fact and figures herein are for information only and do not represent any warranty of any kind.

Document: DOC-0000761885 A / PDO E.00 / date of publication: 13.09.2016 07:48:18 / uncontrolled copy Page 2/2