SETALUX® 17-2450

Technical Datasheet

INTRODUCTION
SETALUX 17-2450 is a hydroxy-functional acrylic polyol for two component vehicle refinish applications. This acrylic polyol is designed for fast curing clearcoat
or single -state paint applications. When SETALUX 17-2450 is combined with appropriate aliphatic polyisocyanates, provides fast cure with a longer pot-life
for excellent application and appearance properties and the excellent attributes of DOI. SETALUX 17-2450 is also has excellent early hardness development
and is buffable in a couple of hours.

TYPE FORM OF DELIVERY (F.O.D)


Acrylic polyol 65% non-volatile in n-butyl propionate
x

PRODUCT DATA PERFORMANCE HIGHLIGHTS


Non-Volatile, by wt.: 65.0 ± 1.0 % · Fast cure, longer pot-life
· Excellent early hardness development
Viscosity (77° F): Z3 – Z5 Gardner Holdt
· Excellent early crosslinking development (MEK rubs)
Acid value, on n.v.: 7 – 12 mg KOH/g · Very good flow-leveling balance and melt-in characteristics
· Excellent clarity, gloss and distinctness of image (DOI)
Color: 50 maximum APHA
x
Appearance: clean, clear and free from SUGGESTED USES
extraneous matter
· 4.0 VOC Clearcoats for vehicle refinish
HEW on n.v.: 460 · Monocoats for vehicle refinish and transportation
Density: 8.54 ± 0.10 lbs/gal · Modifier resin for two component basecoats
x
Flash Point: 100° F Setaflash
STORAGE
Non-volatile, by vol: 59.0%
In the original sealed containers, this product is stable for 3 years at
Reduced viscosity: P –T Gardner – Holdt @ 55% n.v. temperatures up to 100°F
in n-butyl propionate
x
CURING WITH POLYISOCYANATES
Based on 100% conversion of reactive groups the following equation can
be used to calculate the quantity of polyisocyanate needed for
crosslinking 100 parts (Setalux 17-2450) (on solids):

Polyisocyanate = 42 x 100 x OH% (solid resin)


(f.o.d.) 17 x NCO% (f.o.d.)

42 = molecular weight of the NCO-group


17 = molecular weight of the OH-group

Anhydrous solvents as well as solvents free of hydroxyl functional


groups should be used in the presence of polyisocyanates, as
dilution solvents.
x
PRECAUTIONS
Before using SETALUX 17-2450, see the Safety Data Sheet (SDS) for
information on the identified hazards of the material and the
recommended personal protective equipment and procedures.

2.1 / 21.09.2022 (replaces all previous versions) Worldwide Contact Info: www.allnex.com Page 1/2
Disclaimer: allnex Group companies ('allnex') exclude all liability with respect to the use made by anyone of the information contained herein. The information contained herein represents allnex's best
knowledge but does not constitute any express or implied guarantee or warranty as to the accuracy, the completeness or relevance of the data set out herein. Nothing contained herein shall be construed as
conferring any license or right under any patent or other intellectual property rights of allnex or of any third party. The information relating to the products is given for information purposes only. No guarantee
or warranty is provided that the product and/or information is suitable for any specific use, performance or result. Any unauthorized use of the product or information may infringe the intellectual property
rights of allnex, including its patent rights. The user should perform his/her own tests to determine the suitability for a particular purpose. The final choice of use of a product and/or information as well as the
investigation of any possible violation of intellectual property rights or misappropriation of trade secrets of allnex and/or third parties remain the sole responsibility of the user.
Notice: Trademarks indicated with ® , TM or * as well as the allnex name and logo are registered, unregistered or pending trademarks of Allnex Netherlands B.V. or its directly or indirectly affiliated allnex Group
companies. ©2022 allnex Group. All Rights Reserved.
SETALUX® 17-2450
Technical Datasheet

STORAGE AND HANDLING


Care should be taken not to expose the product to high temperature
conditions, direct sunlight, ignition sources, oxidizing agents, alkalis or
acids. Storage and handling should be in stainless steel, amber glass,
amber polyethylene or baked phenolic lined containers. Wash
thoroughly after handling. Keep container tightly closed. Use with
adequate ventilation. See the SDS for the recommended storage
temperature range for SETALUX 17-2450.

version 2.1 Worldwide Contact Info: www.allnex.com Page 2/2


Disclaimer: allnex Group companies ('allnex') exclude all liability with respect to the use made by anyone of the information contained herein. The information contained herein represents allnex's best
knowledge but does not constitute any express or implied guarantee or warranty as to the accuracy, the completeness or relevance of the data set out herein. Nothing contained herein shall be construed as
conferring any license or right under any patent or other intellectual property rights of allnex or of any third party. The information relating to the products is given for information purposes only. No guarantee
or warranty is provided that the product and/or information is suitable for any specific use, performance or result. Any unauthorized use of the product or information may infringe the intellectual property
rights of allnex, including its patent rights. The user should perform his/her own tests to determine the suitability for a particular purpose. The final choice of use of a product and/or information as well as the
investigation of any possible violation of intellectual property rights or misappropriation of trade secrets of allnex and/or third parties remain the sole responsibility of the user.
Notice: Trademarks indicated with ® , TM or * as well as the allnex name and logo are registered, unregistered or pending trademarks of Allnex Netherlands B.V. or its directly or indirectly affiliated allnex Group
companies. ©2019 allnex Group. All Rights Reserved.

You might also like