Nothing Special   »   [go: up one dir, main page]

Balance Work BOQ Original

Download as xlsx, pdf, or txt
Download as xlsx, pdf, or txt
You are on page 1of 242

Construction of ESIC Medical College and Hospital, Bihta, Patna

Abstract of Deviation Statement - 5 (Civil Part)


Sl. No. Description Amount Net Variation Remarks
As per BOQ As per Deviation-4 AS per Deviation -5
DSR Non DSR Total DSR Non DSR Total DSR Non DSR Total
1 2 3 4 5 15 16 17 18 19 20 21 = 20-17 22
1 EARTH WORK 20820025.805 2103268.4049 22923294.2099 38297948.4698 2103268.4049 40401216.8747 39276368.0098 2103268.4049 41379636.4147 978419.54
2 CONCRETE WORK 35222138.1255 0 35222138.1255 25148225.017 19153012.0316 44301237.0486 34751167.4368 26579601.1469 61330768.5837 17029531.5352
3 REINFORCED CEMENT CONCRETE 1099393508 35508564 1134902072 1424620406.64 42665413.1734 1467285819.82 1505427573.13 54219953.2038 1559647526.34 92361706.5192
4 BRICK WORK 114896561.547 0 114896561.547 139834781.903 0 139834781.90 139834781.903 0 139834781.903 0
5 STONE WORK 67793582.3625 0 67793582.3625 1422792.16101 961184.864417 2383977.02543 1422792.16101 961184.864417 2383977.02543 0
6 MARBLE WORK 65554814.0459 115844434.5 181399248.546 60457425.7773 149951883.494 210409309.272 85056757.3533 164000296.244 249057053.598 38647744.326
7 WOOD AND PVC WORK 69930219.79 43724911 113655130.79 62125120.7547 176660471.966 238785592.721 65623412.5093 186261614.601 251885027.11 13099434.3894
8 STEEL WORK 49784747.425 31170375 80955122.425 28845089.9794 39849640.2274 68694730.2068 33877228.5732 39849640.2274 73726868.8006 5032138.59375
9 FLOORING 157724990.545 26028234 183753224.545 153380422.031 39786831.3247 193167253.356 148301128.031 44866125.32 193167253.356 0
10 ROOFING 59548440.779 0 59548440.779 68034712.2848 121097828.34 189132540.624 67997633.4848 122570749.139 190568382.624 1435841.99967
11 FINISHING 85118125.517 13706400 98824525.517 85638707.9235 7359684.22849 92998392.152 97222338.6831 7359684.22849 104582022.912 11583630.7597
12 ROAD WORK 91116852.59 0 91116852.59 117069024.533 0 117069024.533 117069024.533 0 117069024.533 0
13 ALUMINIUM WORK 108147325.987 0 108147325.987 108057916.387 0 108057916.387 109552396.737 0 109552396.737 1494480.35
14 WATER PROOFING 29524779.9935 0 29524779.9935 38587536.4589 0 38587536.4589 38587536.4589 0 38587536.4589 0
15 HORTICULTURE AND LANDSCAPE WORKS 644928.25 2376364 3021292.25 644928.25 2376364 3021292.25 644928.25 2376364 3021292.25 0
16 SANITARY INSTALLATIONS 10350203.55 90935289 101285492.55 12610963 94627380.19 107238343.19 12981649.75 72713180.59 85694830.34 -21543512.85
17 WATER SUPPLY 35819826.35 58390147.46 94209973.81 37355828.93 60207286.01 97563114.94 33121810.38 16970105.61 50091915.99 -47471198.95
18 DRAINAGE 16171201.05 12427550 28598751.05 10822790 13823425 24646215 16192550.3 13631675.00 29824225.3 5178010.3
SUB TOTAL = ( A ) = 2117562271.67 432215537.365 2549777809 2412954620.5 770623673.255 3183578293.76 2546941077.69 117826226.513
ADD COSTINDEX 22% ON DSR ITEMS ( B ) = 465863699.768 465863699.768 530850016.511 530850016.511 560327037.091 560327037.091 29477020.5802

TOTAL AMOUNT = A + B 2583425971.44 432215537.365 3015641508.8 2943804637 770623673.255 3714428310.27 3107268114.78 754463442.585 3861731557.36 147303247.09

Page 1 of 242
Construction of ESIC Medical College comprising of Hospital Building, Medical College, Hostels, Residential Complex including allied services at Bihta Patna (At
the risk and cost of previous Agency).

BALANCE WORK SUMMARY SHEET

Amount
Sl. No. Name of Sub Head
DSR Non-DSR Total

1 Civil Works, Plumbing & Site Development Works 740,394,528.90 238,430,584.84 978,825,113.74

2 Interiors Works 162,741,852.16 162,741,852.16

3 Fire Fighting Works 74,948,072.00 74,948,072.00

4 Fire Alarm Works 8,217,269.74 67,382,142.00 75,599,411.74

5 Electrical Works 50,722,701.70 317,369,908.00 368,092,609.70

6 STP Works 10,926,280.00 10,926,280.00

7 HVAC Works 459,153,989.00 459,153,989.00

8 LIFT Works 43,958,200.00 43,958,200.00

9 Pump & Equipments 186,045.12 1,695,879.00 1,881,924.12

10 Building Management System 1,717,516.00 19,151,643.00 20,869,159.00

11 Solar Heating 26,619,676.00 26,619,676.00

12 Hot Water Boiler 3,661,161.00 3,661,161.00

13 Diesel Generator Set 666,141.96 155,452,339.00 156,118,480.96

14 Switch Yard 66 x 11 KVA (Deleted)

. 801,904,203.42 1,581,491,726.00 2,383,395,929.42


Grand Total 2,383,395,929.42
Balance work for Construction of ESIC Medical College and Hospital at Bihta ,Patna(Bihar)
Balance work for CVIL, PLUMBING & SITE DEVELOPMENT WORKS
Amount
Sl. No. Description Remarks
DSR Non DSR Total

1 EARTH WORK 5416180.23 1122056.78 6538237.01

2 CONCRETE WORK 8926419.47 8926419.47

3 REINFORCED CEMENT CONCRETE 25105603.59 32500.00 25138103.59

4 BRICK WORK 20638777.49 0.00 20638777.49

5 STONE WORK 67793582.36 0.00 67793582.36

6 MARBLE WORK 14531546.39 4654875.00 19186421.39

7 WOOD AND PVC WORK 30483603.15 142535225.00 173018828.15

8 STEEL WORK 18467242.99 672500.00 19139742.99

9 FLOORING 72578670.96 7580985.00 80159655.96

10 ROOFING 31992495.18 0.00 31992495.18

11 FINISHING 59648770.60 120000.00 59768770.60

12 ROAD WORK 100510348.10 0.00 100510348.10

13 SANITARY INSTALLATIONS 8293536.70 59158121.00 67451657.70

14 WATER SUPPLY 29932175.60 9876708.06 39808883.66

15 DRAINAGE 6265422.77 10301250.00 16566672.77

16 ALUMINIUM WORK 101272649.19 0.00 101272649.19

17 WATER PROOFING 4378808.39 0.00 4378808.39

18 HORTICULTURE AND LANDSCAPE WORKS 644928.25 2376364.00 3021292.25

SUB TOTAL = ( A ) = 606880761.39 238430584.84 845311346.23

ADD COSTINDEX 22% ON DSR ITEMS ( B ) = 133513767.51 133513767.51

TOTAL AMOUNT = A + B 740394528.90 238430584.84 978825113.74

Page 3 of 242
Balance work for Construction of ESIC Medical College and Hospital at Bihta ,Patna(Bihar)

Civil & Plumbing Work


Quantity Amount
S. No. Item Code Item of Work Unit Rate Remarks
DSR Non DSR DSR Non DSR
1 2 3 4 5 6 7 8 9 10
SCHEDULED ITEMS
EARTH WORK

Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding
1 2.6 30cm in depth. 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m
and lift upto 1.5m, disposed earth to be levelled and neatly dressed.

2.6.1 All kinds of soil cum 101.85 7339.79 747557.61

Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of
sides, ramming of bottoms, depth upto 1.5 m including getting out the excavated soil, and then returning the soil
2 2.10 as required, in layers not exceeding 20 cm in depth equ ed, aye s ot e ceed g 0 c dept including consolidating 0.00 0.00 0.00
each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a
lead of 50 m :

2.10.1 All kinds of soil 0.00 0.00 0.00

2.10.1.1 Pipes, cables etc. exceeding 80 mm dia. metre 70.45 6045.00 425870.25

2.10.1.2 Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia. metre 115.05 3613.23 415701.54

2.10.1.3 Pipes, cables etc. exceeding 300 mm dia but not exceeding 600 mm. metre 179.65 1685.00 302710.25

Extra for excavating trenches for pipes, cables etc. in all kinds of soil for depth exceeding 1.5 m, but not
3 2.11 0.00 0.00 0.00
exceeding 3 m. (Rate is over corresponding basic item for depth upto 1.5 metre).

a) Pipes .cables etc.exceeding 80 mm dia but not exceeding 300 mm dia. cum 153.02 352.00 53863.04

b) Pipes .cables etc.exceeding 300 mm dia but not exceeding 600 mm dia. cum 238.93 150.00 35839.50

Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not
4 2.25 exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift cum 45.70 29572.22 1351450.50
upto 1.5 m.

5 2.26 Extra for every additional lift of 1.5 m or part thereof in. 0.00 0.00 0.00
2.26.1 All kinds of soil. cum 18.90 706.40 13350.96
Supplying and filling in plinth with Locally availble sand under floors including, watering, ramming consolidating
6 2.27 cum 301.50 8868.97 2673995.47
and dressing complete.

7 2.34 Supplying chemical emulsion in sealed containers including delivery as specified. 0.00 0.00 0.00

2.34.1 Chlorpyriphos/ Lindane emulsifiable concentrate of 20% litre 174.30 0 0

8 2.36 Deduct for disposed soil not levelled and neatly dressed (against Item No. 2.6,&2.7) cum -13.85 43621.58 -604158.88

Diluting and injecting chemical emulsion for pre constructional anti-termite treatment and creating a continous
chemical barrier under all round the column pits, wall trenches, basement excavation, top surface plinth filling,
9 NSI junction of wall and floor, along the external perimeter of the building, expansion joints over the top surface of 0.00 0.00
consolidated earth on which apron is to be laid, sorrounding of pipes and conduits etc. complete as per
specifications.( plinth are of the building at ground floor only shall be measured in sqm for payment

NSI With chloropyriphos emulsifiable concentrates of 20 % with 1 % concentration. Sqm 76.57 14654.00 0.00 1122056.78

TOTAL EARTH WORK 5416180.23 1122056.78

CONCRETEWORK

Providing and laying in position cement concrete of specified grade excluding the cost of centring and
10 4.1 0.00 0.00
shuttering - All work upto plinth level

4.1.5 1:3:6(1 cement: 3 coarse sand: 6 graded stone aggregate 20mm nominal size) cum 2791.05 1311.02 3659129.07

4 of 242
Balance work for Construction of ESIC Medical College and Hospital at Bihta ,Patna(Bihar)

Civil & Plumbing Work


Quantity Amount
S. No. Item Code Item of Work Unit Rate Remarks
DSR Non DSR DSR Non DSR
1 2 3 4 5 6 7 8 9 10

4.1.8 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). cum 2449.00 1741.13 4264037.12

4.1.10 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) cum 2237.75 0 0

Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached
pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping,
11 4.2 0.00 0.00 0.00
bed blocks, anchor blocks, plain window sills, fillets etc. upto floor five level, excluding the cost of centring,
shuttering and finishing :

4.2.3 1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cum 3579.10 0.50 1789.55

Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4
12 4.10 sqm 144.15 657.43 94768.53
graded stone aggregate 12.5mm nominal size).

13 4.12 Extra for providing and mixing water proofing material in cement concrete work @ 1 kg per 50kg of cement. 50/kg 27.45 21.46 589.08

Applying a coat of residual petroleum bitumen of penetration 80/100 of approved quality using 1.7kg per square
14 4.13 metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly sqm 58.60 880.17 51577.96
soaked in kerosene oil.

Extra for concrete work in superstructure above floor V


15 4.14 cum 235.65 404.00 95202.60
level for each four floors or part thereof.

Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone
16 4.17 aggregate 20 mm nominal size) over 75mm bed by dry brick ballast 40mm nominal size well rammed and sqm 222.65 3410.40 759325.56
consolidated and grouted with fine sand including finishing the top smooth.

TOTAL C O N C R E T E W O R K 8926419.47

REINFORCED CEMENT CONCRETE

Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring,
17 5.1 0.00 0.00
shuttering, finishing and reinforcement - All work upto plinth level :

1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone


5.1.2 cum 3732.00 219.00 817308.00
aggregate 20 mm nominal size)

Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and
18 5.2 string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto floor five level excluding cost 0.00 0.00
of centring, shuttering, finishing and reinforcement :

1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone


5.2.2 cum 4092.35 27.00 110493.45
aggregate 20 mm nominal size)
Centring and shuttering including strutting, propping etc.
19 5.9 0.00 0.00
and removal of form for :

5.9.1 Foundations, footings, bases of columns, etc. for mass concrete. sqm 119.25 0 0

Walls (any thickness) including attached pilasters,


5.9.2 sqm 180.40 11647.97 2101293.56
buttresses, plinth and string courses etc.
5.9.3 Suspended floors, roofs, landings, balconies and access platform. sqm 187.35 22165.25 4152659.59
5.9.4 Shelves (Cast in situ) sqm 187.35 2901.47 543589.73
5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers. sqm 162.65 37.40 6082.77

5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts. sqm 238.40 0 0

5.9.7 Stairs, (excluding landings) except spiral-staircases. sqm 204.00 3019.83 616045.83

5 of 242
Balance work for Construction of ESIC Medical College and Hospital at Bihta ,Patna(Bihar)

Civil & Plumbing Work


Quantity Amount
S. No. Item Code Item of Work Unit Rate Remarks
DSR Non DSR DSR Non DSR
1 2 3 4 5 6 7 8 9 10

5.9.8 Spiral staircases (including landing). sqm 182.70 699.00 127707.30

5.9.16 Edges of slabs and breaks in floors and walls. 0.00 0.00

5.9.16.1 Under 20 cm wide metre 61.10 33732.64 2061064.30

5.9.19 Weather shade, Chajjas, corbels etc., including edges. sqm 258.60 2583.82 668175.85

5.9.20 Item deleted sqm 0 0 0.00

5.9.21 Item deleted sqm 0 0 0.00

Extra for additional height in centring, shuttering where ever required with adequate bracing, propping etc.
20 5.11 including cost of de-shuttering and decentring at all levels, over a height of 3.5 m, for every additional height of 0.00 0.00 0.00
1 metre or part thereof (Plan area to be measured)
Suspended floors, roofs, landing, beams and balconies
5.11.1 sqm 70.20 2250.00 157950.00
(Plan area to be measured).
Providing precast cement concrete Jali 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6mm
nominal size) reinforced with 1.6 mm dia mild steel wire including centring and shuttering, roughening cleaning,
21 5.18 0.00 0.00 0.00
fixing and finishing in cement mortar 1:3 (1 cement: 3 fine sand) etc. complete excluding plastering of the
jambs, sills and soffits.

5.18.1 50 mm thick sqm 359.25 38.00 13651.50

Reinforcement for R.C.C. work including straightening,


22 5.22 cutting, bending, placing in position and binding all 0.00 0.00 0.00
complete.

5.22.1 Thermo-Mechanically Treated bars. kg 42.70 143019.75 6106943.33

per cm
Providing and fixing in position 12mm thick bitumen impregnated fibre board conforming to IS:1838 including depth
23 5.28 334.55 1800000.00 6021900.00
cost of primer, sealing compound in expansion joints. per per
100 mts.
Providing and fixing sheet covering over expansion joints with iron screws as per design to match the
24 5.29 0.00 0.00
colour/shade of wall treatment
5.29.1 Non asbestos fibre cement board 6 mm thick as per IS:14862 0.00 0.00
5.29.1.2 200 mm wide metre 93.80 105.00 9849.00

5.29.2 Aluminium fluted strips 3.15mm thick. 0.00 0.00


5.29.2 200 mm wide. metre 368.40 900.00 331560.00

Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement
concrete of specified grade for reinforced cement concrete work including pumping of concrete to site of laying
but excluding the cost of centring, shuttering, finishing and reinforcement. including Admixtures in
25 5.33 cum 4147.40 150.00 622110.00
recommended proportions as per IS 9103 to accelerate, retard setting of concrete, improve workability without
impairing strength and durability as per direction of Engineer-in-charge. M-25 grade reinforced cement concrete
by using 410kg. of cement per cum of concrete. All work upto floor V level.

Add or deduct for providing richer or leaner mixes


26 5.34 0.00 0.00
respectively at all floor levels.
Providing M-30 grade concrete by using 420kg of cement per cum of concrete instead of M-25 grade B.M.C/
5.34.1 cum 54.55 512.36 27949.24
R.M.C.
Providing M-40 grade concrete by using 435kg of cement per cum of concrete instead of M-25 grade B.M.C./
5.34.3 cum 136.40 595.70 81253.48
R.M.C.

27 5.38 Extra for R.C.C./ B.M.C/ R.M.C. work above floor V level for each four floors or part thereof. cum 92.90 5683.71 528016.66

6 of 242
Balance work for Construction of ESIC Medical College and Hospital at Bihta ,Patna(Bihar)

Civil & Plumbing Work


Quantity Amount
S. No. Item Code Item of Work Unit Rate Remarks
DSR Non DSR DSR Non DSR
1 2 3 4 5 6 7 8 9 10
Extra for mixing in concrete 3 S Triangular Cross section Polyester Fibre 12 mm in length or equivalent @ 0.25
28 NSI kg 325.00 100.00 0.00 32500.00
% by cement weight in design mix.
TOTAL REINFORCED CEMENT CONCRETE 25105603.59 32500.00

BRICKWORK
Brick work with F.P.S. bricks of class designation 75 in foundation and plinth in:
29 6.1 0.00 0.00

6.1.2 Cement mortar 1:6 (1 cement : 6 coarse sand) cum 2121.75 2173.25 4611092.85

Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all
30 6.4 shapes and sizes in : 0.00 0.00

6.4.2 Cement mortar 1:6 (1 cement : 6 coarse sand) cum 2430.25 4609.32 11201799.93

Extra for brick work in superstructure above floor V level for each four floors or part thereof by mechanical
31 6.5 means by lifting material using mobile crane . cum 190.00 4563.63 867089.70

Brick work in plain arches in superstructure including centring and shuttering complete for span upto 6 metres
32 6.9 with F.P.S. brick of class designation 75 in cement mortar 1:3 (1 cement : 3 coarse sand). cum 3847.45 23.00 88491.35

Half brick masonry with F.P.S. brick of class designation y g 75 in foundations and plinth in :
33 6.12 0.00 0.00 0.00

6.12.2. cement mortar 1:4 (1 cement : 4 coarse sand) sqm 270.35 1090.40 294789.64

Half brick masonry with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V
34 6.13 level. 0.00 0.00 0.00

6.13.2 Cement mortar 1:4 (1 cement :4 coarse sand) sqm 302.80 9122.55 2762308.14

Extra for half brick masonry in superstructure, above floor V level for every four floors or part thereof by
35 6.14 mechanical means by lifting material using mobile crane. sqm 16.85 18736.73 315713.90

Extra for providing and placing in position 2 Nos. 6mm dia. M.S. bars at every third course of half brick masonry
36 6.15 (with F.P.S. bricks). sqm 47.80 9368.19 447799.48

Brick edging 7cm wide 11.4cm deep to plinth protection with bricks of class designation 75 including grouting
37 6.44 with cement mortar 1:4 (1 cement : 4 fine sand). metre 16.25 3058.00 49692.50

TOTAL BRICK WORK 20638777.49

STONE WORK
Providing and fixing copper pins 7.5 cm long 6 mm diameter for securing adjacent stones in stone wall lining in
cement mortar 1:2 (1 cement : 2 coarse sand) including making the necessary chases.
38 7.27 each 20.00 7260.00 145200.00

Stone tile work for wall lining upto 10 m height with special adhesive over 12 mm thick bed of cement mortar 1:3
( 1 cement :3 coarse sand ) including pointing in white cement with an admixture of pigment to match the stone
39 7.38 shade 0.00 0.00 0.00

7.38.1 8 mm thick (mirror polished and machine cut edge ) 0.00 0.00 0.00
7.38.1.1 Granite stone of any colour and shade. sqm 1043.75 49732.35 51908140.31

7 of 242
Balance work for Construction of ESIC Medical College and Hospital at Bihta ,Patna(Bihar)

Civil & Plumbing Work


Quantity Amount
S. No. Item Code Item of Work Unit Rate Remarks
DSR Non DSR DSR Non DSR
1 2 3 4 5 6 7 8 9 10
Providing and fixing dry cladding upto 10 metre heights with 30mm thick gang saw cut stone with (machine cut
edges) of uniform colour and size upto 1mx1m, fixed to structural steel frame work and/ or with the help of
cramps, pins etc. and sealing the joints with approved weather sealant as per Architectural drawing and
direction of Engineer-in-charge. (The steel frame work, stainless steel cramps and pins etc. shall be paid for
40 7.40 separately.) 0.00 0.00 0.00

7.40.1 Red sand stone. sqm 1323.40 8366.00 11071564.40


7.40.2 White sand stone sqm 1382.35 1999.00 2763317.65

Providing and fixing structural steel frame (for dry cladding with 30 mm thick gang saw cut with machine cut
edges sand stone) on walls at all heights using M.S. square/ rectangular tube in the required pattern as per
architectural drawing including cost of cutting, bending, welding etc. The frame work shall be supported in wall
with the help of MS brackets/ lugs of angle iron/ flats etc. which shall be welded to the frame and embedded in
brick wall with cement concrete block 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal
size) of size 300x230x300mm including cost of necessary centring and shuttering and with approved expansion
hold fasteners on CC/RCC surface including drilling necessary holes. Approved cramps/ pins etc. shall be
welded to the frame work to support stone cladding the steel work will be given a priming coat of "ZINC" primer
as approved by Engineer- p g p pp y g in-charge and painted with two or more coats of epoxy paint (Shop
41 7.41 drawings shall be submitted by the contractor to the Engineer-in-charge for approval before execution). The kg 77.80 10200.00 793560.00
frame work shall be fixed in true horizontal & vertical lines/planes. (Only structural steel frame work shall be

Providing and fixing adjustable stainless steel cramps of approved quality and of required shape and size
adjustable with stainless steel nuts bolts and washer (total weight not less than 260 gms) for dry stone cladding
fixed on frame work at suitable location including making necessary recesses in stone slab, drilling required
42 7.42 holes etc complete as per direction of the Engineer-in-charge. each 272.50 4080.00 1111800.00

TOTAL STONE WORK 0.00 67793582.36 0.00

MARBLEWORK

Marble work gang saw cut (polished and machine cut) of thickness 18mm for wall lining (veneer work) in
cement mortar 1:3 (1 cement : 3 coarse sand) including pointing with white cement mortar 1:2 (1 white cement :
43 8.1 0.00 0.00
2 marble dust) with an admixture of pigment to match the marble shade: (To be secured to the backing by
means of cramps, which shall be paid for separately).

Raj Nagar Plain white marble/ Udaipur green marble/


8.1.1 Zebra black marble. 0.00 0.00

8.1.1.1 Area of slab upto 0.50 sqm sqm 1511.60 0.00

Providing and fixing 18mm thick gang saw cut mirror polished (premoulded and prepolished) machine cut for
kitchen platforms, vanity counters window sills facias and p , y , , similar locations of required size of approved
shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints
treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing moulding
44 8.2 and polishing to edge to give high gloss finish etc. complete at all levels. 0.00 0.00 0.00

Raj Nagar Plain white marble/ Udaipur green marble/


8.2.1 Zebra black marble. 0.00 0.00 0.00
8.2.1.2 Area of slab over 0.50 sum. sqm 1358.15 958.00 1301107.70

8 of 242
Balance work for Construction of ESIC Medical College and Hospital at Bihta ,Patna(Bihar)

Civil & Plumbing Work


Quantity Amount
S. No. Item Code Item of Work Unit Rate Remarks
DSR Non DSR DSR Non DSR
1 2 3 4 5 6 7 8 9 10
8.2.2 Granite of any colour and shade 0.00 0.00 0.00
8.2.2.1 Area of slab upto 0.50 sqm sqm 2480.20 150.00 372030.00
8.2.2.2 Area of slab over 0.50 sqm. sqm 2575.10 2000.00 5150200.00
Extra for providing edge moulding to 18mm thick marble stone counters, Vanities etc. including machine
polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.
45 8.3 0.00 0.00 0.00

8.3.2 Granite work. metre 97.60 36522.11 3564557.94

Extra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity
46 8.5 counters and similar location in marble/Granite/stone work including necessary holes for pillar taps etc. each 151.00 2318.00 350018.00
including rubbing and polishing of cut edges etc. complete.

Providing and fixing cramps of required size & shape in RCC/ CC backing with cement mortar 1:2 ( 1 cement :2
coarse sand) including drilling necessary hole in stones and embedding the cramp in the hole (fastener to be
47 8.7 paid separately). 0.00 0.00 0.00

8.7.2 Stainless steel cramps. kg 529.50 4906.00 2597727.00

Stone tile (polished) work for wall lining over 12mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand)
and cement slurry @ 3.3 kg/sqm including pointing in white cement complete.
48 8.9 0.00 0.00 0.00

8.9.1 8mm thick. 0.00 0.00 0.00


8.9.1.2 Granite of any colour and shade. sqm 1116.30 1000.00 1116300.00

Providing and fixing stone slab table rubbed, edges rounded and polished of size 75x50 cm deep and 1.8 cm
thick fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone
in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone
aggregate 6 mm nominal size) as per direction of Engineerin- charge and finished smooth.
49 8.10 0.00 0.00 0.00

8.10.1 White Agaria Marble Stone. sqm 2274.45 35.00 79605.75


Providing and fixing 18mm thick gang saw cut mirror polished (premoulded and prepolished) machine cut for
flooring of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1
cement : 4 coarse sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups,
derieved
50 including rubbing, curing moulding and polishing to edge to give high gloss finish etc. complete at all levels. 0.00 0.00 0.00
from 8.2
NSI

Granite of any colour and shade 0.00 0.00 0.00


Area of slab over 0.50 sqm. sqm 3103.25 1500.00 4654875.00

TOTAL M A R B L E W O R K 0.00 14531546.39 4654875.00

WOOD AND P. V. C. WORK

Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and
51 9.1 fixed in position : 0.00 0.00

9.1.1 Second class teak wood 0.00 0.00


9.1.1.1 35 mm thick cum 52090.00 82.94 4320344.60
9.1.3 Kiln seasoned and chemically treated hollock wood cum 31339.45 92.40 2895765.18

9 of 242
Balance work for Construction of ESIC Medical College and Hospital at Bihta ,Patna(Bihar)

Civil & Plumbing Work


Quantity Amount
S. No. Item Code Item of Work Unit Rate Remarks
DSR Non DSR DSR Non DSR
1 2 3 4 5 6 7 8 9 10
Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows
including ISI marked black enamelled M.S butt hinges with necessary screws excluding, panelling which will be
52 9.5 paid for separately. 0.00 0.00 0.00

9.5.1 Second class teak wood 0.00 0.00 0.00


9.5.1.1 35 mm thick shutters sqm 1373.65 20.00 27473.00

Providing and fixing 35 mm thick factory made laminated veneer lumber door shutter conforming to IS : 14616
and TADS 15:2001 (Part B) ncluding ISI marked black enamelled M.S. butt hinges with necessary screws as
per directions of Engineer-in-charge and panelling with panels of:
53 9.6 0.00 0.00 0.00

12 mm thick pre-laminated particle board (decorative lamination on both sides) grade - 1, medium density flat
pressed, three layer particle board FPT - I or graded wood particle board FPT - I, conforming to IS : 3087
bonded with BWP type synthetic resin adhesive as per IS : 848 and pre-lamination conforming to IS : 12823
9.6.2 Grade 1, Type - II marked: sqm 2014.25 50.00 100712.50

Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass
panes including black enamelled ISI marked M.S butt hinges with necessary screws.
54 9.9 0.00 0.00 0.00

9.9.1 Second class teak wood 0.00 0.00 0.00


9.9.1.1 35 mm thick sqm 1718.30 50.00 85915.00

Providing and fixing factory made laminated veneer lumber glazed shutter conforming to lS : 14616 and TADS
15:2001 (Part B) , using 4mm thick float glass panes for doors, windows and clerestory windows including ISI
marked black enamelled M.S butt hinges with necessary screws as per directions of Engineer-in-charge
55 9.10 0.00 0.00 0.00

9.10.1 30 mm thick shutters sqm 1633.25 25.00 40831.25

Providing and fixing Pre-laminated flat pressed 3 layer (medium density) particle board or graded wood particle
board IS : 3087 marked with one side decorative and other side balancing lamination Grade I, Type II exterior
grade IS : 12823 marked in shelves with screws and fittings wherever required, edges to be painted with
56 9.18 polyurethane primer (fittings to be paid separately). 0.00 0.00 0.00

9.18.2 25 mm thick sqm 1009.70 10.00 10097.00

Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) decorative type, core of block
board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains
or cross bands and face veneers on both faces of shutters.
57 9.20 0.00 0.00 0.00

35 mm thick including ISI marked Stainless Steel butt


9.20.1 sqm 1473.50 40.00 58940.00
hinges with necessary screws.

25 mm thick (for cupboard) including ISI marked nickel plated bright finished M.S. Piano hinges IS : 3818
9.20.3 sqm 1317.65 15.00 19764.75
marked with necessary screws.

10 of 242
Balance work for Construction of ESIC Medical College and Hospital at Bihta ,Patna(Bihar)

Civil & Plumbing Work


Quantity Amount
S. No. Item Code Item of Work Unit Rate Remarks
DSR Non DSR DSR Non DSR
1 2 3 4 5 6 7 8 9 10
Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) non-decorative type, core of
block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with
58 9.21 vertical grains or cross bands and face veneers on both faces of shutters : 0.00 0.00 0.00

9.21.1 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. sqm 929.95 7142.00 6641702.90
30 mm thick including ISI marked Stainless Steel butt
9.21.2 sqm 904.40 1078.57 975458.71
hinges with necessary screws.
Deduction for not providing ISI marked Stainless steel butt hinges of required size for fixing of 30 mm Flush
Door Shutter In DSR item Code 9.21.2 sqm -78.50 4187.00 -328679.50
25 mm thick (for cupboard) including ISI marked nickel plated bright finished M.S. Piano hinges with necessary
9.21.3 screws. sqm 853.05 1148.00 979301.40

59 9.22 Extra for Providing and fixing flush doors with decorative veneering 0.00 0.00 0.00

9.22.1 On one side in item no. 9.21 sqm 261.35 13407.00 3503919.45

Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of shutters
(over all area of door shutter to be measured) Over item no. 9.20 and 9.21.
60 9.23 sqm 284.55 5310.17 1511008.87

Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded) (overall
61 9.24 area of door shutter to be measured) 0.00 0.00 0.00

9.24.1 Rectangular or square. sqm 99.90 2262.00 225973.80

9.24.2 Circular. sqm 137.05 10.00 1370.50

Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured).
62 9.26 sqm 66.20 1063.00 70370.60

Providing and fixing 35mm thick wire gauze shutters using galvanised M.S. wire gauze of average width of
aperture 1.4mm with wire of dia. 0.63 mm for doors, windows and clerestory windows including ISI marked
63 9.27 bright finished or/and black enamelled M.S. butt hinges with necessary screws 0.00 0.00 0.00

9.27.1 Second class teak wood. sqm 1548.90 30.00 46467.00

Providing and fixing 35 mm thick wire gauge shutters using galvanised M.S wire gauge of average width of
aperture 1.4 mm with wire of dia.0.63 mm for doors, windows and clerestory windows including ISI marked
64 9.28 stainless steel butt hinges with necessary screws : 0.00 0.00 0.00

9.28.1 Second class teak wood sqm 1632.70 500.00 816350.00

Providing and fixing wire gauze laminated veneer lumber shutters conforming to IS : 14616, and as per TADS
15 :2001 (Part B) using galvanised wire gauze with average width of aperture 1.4mm in both directions with
wire of dia 0.63mm as per IS :1568 for doors, windows and clerestory windows including ISI marked bright
finished or/ and black enamelled M.S. butt hinges with necessary screws as per directions of Engineer-in-
65 9.31 charge: 0.00 0.00 0.00

9.31.1 35 mm thick shutters sqm 1677.40 50.00 83870.00


9.31.2 30 mm thick shutters sqm 1470.65 30.00 44119.50

11 of 242
Balance work for Construction of ESIC Medical College and Hospital at Bihta ,Patna(Bihar)

Civil & Plumbing Work


Quantity Amount
S. No. Item Code Item of Work Unit Rate Remarks
DSR Non DSR DSR Non DSR
1 2 3 4 5 6 7 8 9 10

Providing and fixing skirting of Pre-laminated with (one side decorative and other side balancing lamination) flat
pressed, 3 layer or graded particle board (medium density) Grade I, Type II, IS :12823 marked, with necessary
fixing arrangements and screws including drilling necessary holes for rawl plugs etc. and priming coat on
66 9.39 unexposed surface complete : 0.00 0.00 0.00

9.39.1 18 mm thick sqm 1150.35 10.00 11503.50

Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming
67 9.40 coat on unexposed surface etc. complete 0.00 0.00 0.00

9.40.1 2nd class teak wood 0.00 0.00 0.00


9.40.1.1 50x12 mm metre 53.85 10.00 538.50

Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round
68 9.48. bars etc. all complete. 0.00 0.00 0.00

9.48.1 Fixed to steel windows by welding. kg 59.25 14943.98 885430.82


9.48.2 Fixed to openings /wooden frames with rawl plugs screws etc. kg 64.40 31448.33 2025272.45

Providing and fixing fly proof galvanised M.S. wire gauze to windows and clerestory windows using galvanised
M.S. wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.63 mm.
69 9.51 0.00 0.00 0.00

9.51.2 With 12 mm mild steel U beading. sqm 291.95 3241.00 946209.95

Providing 40x3 mm flat iron hold fasts 40 cm. long including fixing to frame with 10 mm diameter bolts,nuts and
70 9.53 wooden plugs and embedding in cement concrete blocks 30x10x15 cm.1:3:6 mix ( 1 cement :3 coarse sand :6 each 61.50 340.00 20910.00
graded stone aggregate 20 mm nominal size )

Providing and fixing oxidised M.S. double acting spring hinges with necessary screws etc. complete.
71 9.60 0.00 0.00 0.00

9.60.2 125 mm each 86.95 10.00 869.50

Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete
72 9.62 0.00 0.00 0.00

9.62.1 300x16 mm each 79.60 50.00 3980.00

Providing and fixing ISI marked oxidised M.S. tower bolt


73 9.63 black finish, (Barrel type) with necessary screws etc. 0.00 0.00 0.00
complete :
9.63.1 250x10 mm each 33.90 50.00 1695.00
9.63.2 200x10 mm each 28.60 100.00 2860.00
9.63.3 150x10 mm each 23.40 50.00 1170.00
9.63.4 100x10 mm each 17.25 50.00 862.50

Providing and fixing ISI marked 85x42mm oxidised M.S. pull bolt lock conforming to IS : 7534 with necessary
74 9.64 screws bolts, nut and washers etc. complete. each 36.20 50.00 1810.00

Providing and fixing ISI marked oxidised M.S. door latches conforming to IS:5930 with screws etc. complete :
75 9.65 0.00 0.00 0.00

12 of 242
Balance work for Construction of ESIC Medical College and Hospital at Bihta ,Patna(Bihar)

Civil & Plumbing Work


Quantity Amount
S. No. Item Code Item of Work Unit Rate Remarks
DSR Non DSR DSR Non DSR
1 2 3 4 5 6 7 8 9 10
9.65.1 300x20x6 mm each 33.10 50.00 1655.00

Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc.
76 9.66 complete : 0.00 0.00 0.00

9.66.1 125 mm each 10.20 50.00 510.00


9.66.2 100 mm each 7.75 50.00 387.50

Providing and fixing oxidised M.S. hasp and staple (safety type) conforming to IS : 363 with necessary screws
77 9.67 complete : 0.00 0.00 0.00

9.67.2 115 mm each 10.95 50.00 547.50

Providing and fixing oxidised M.S. casement stays (straight peg type) with necessary screws etc. complete.
78 9.98 0.00 0.00 0.00

9.68.1 300 mm weighing not less than 200 gms. each 19.15 3888.00 74455.20

Providing and fixing oxidised M.S. Safety chain with necessary fixtures for doors. (Weighing not less than 450
79 9.69 gms.) each 52.80 316.00 16684.80

Providing and fixing bright finished 100 mm mortice latch and lock with 6 levers and a pair of lever handles with
80 9.76 necessary screws etc. complete ( best make of approved quality ) each 332.65 50.00 16632.50

Providing and fixing bright finished 100 mm mortice latch with one dead bolt and a pair of lever handles with
81 9.77 necessary screws etc. complete ( best make of approved quality ) each 307.10 7.00 2149.70

Providing and fixing special quality bright finished brass cupboard or wardrobe locks with four levers including
necessary screws etc. complete (best make of approved quality) :
82 9.79 0.00 0.00 0.00

9.79.2 50 mm each 84.10 906.00 76194.60

Providing and fixing 50 mm bright finished brass cup board or wardrobe knob with necessary screws (best
83 9.80 each 23.70 1492.00 35360.40
make of approved quality)

Providing and fixing bright finished brass handles with


84 9.81 screws etc. complete 0.00 0.00 0.00

9.81.1 125 mm each 103.65 50.00 5182.50

Providing and fixing IS : 3564 marked aluminium extruded section body tubular type universal hydraulic door
closer with double speed adjustment with necessary accessories and screws etc. complete.
85 9.84 each 911.10 40.38 36790.22

Providing and fixing bright finished brass hasp and staple (safety type) with necessary screws etc. complete:
86 9.87 0.00 0.00 0.00

9.87.3 90 mm each 40.75 10.00 407.50

Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC
10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete :
87 9.96 0.00 0.00 0.00

9.96.1 300x16 mm each 158.50 6162.00 976677.00


9.96.2 250x16 mm each 134.10 10.00 1341.00

13 of 242
Balance work for Construction of ESIC Medical College and Hospital at Bihta ,Patna(Bihar)

Civil & Plumbing Work


Quantity Amount
S. No. Item Code Item of Work Unit Rate Remarks
DSR Non DSR DSR Non DSR
1 2 3 4 5 6 7 8 9 10
Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as
per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete :
88 9.97 0.00 0.00 0.00

9.97.1 300x10 mm each 71.45 8.00 571.60


9.97.2 250x10 mm each 62.20 7542.00 469112.40
9.97.4 150x10 mm each 42.75 17312.00 740088.00
9.97.5 100x10 mm each 32.15 3565.00 114614.75

Providing and fixing aluminium pull bolt lock anodised ISI marked (anodic coating not less than grade AC 10 as
per IS : 1868) transparent or dyed to required colour and shade with necessary screws bolts, nut and washers
89 9.98 etc. complete. each 44.35 1697.00 75261.95

Providing and fixing 50cm long aluminium kicking plate 100x3.15 mm anodised (anodic coating not less than
grade AC 10 as per IS :1868) transparent or dyed to required colour or shade with necessary screws etc.
90 9.99 complete. each 115.70 3854.00 445907.80

Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC 10 as per
IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete
91 9.100 0.00 0.00 0.00

9.100.1 125 mm each 48.80 10424.00 508691.20


9.100.2 100 mm each 35.30 8276.00 292142.80

Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than
grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with necessary screws etc.
92 9.101 complete. 0.00 0.00 0.00

9.101.2 Twin rubber stopper each 53.90 4158.00 224116.20

Providing and fixing aluminium casement stays ISI marked anodised (anodic coating not less than grade AC 10
as per IS : 1868) transparent or dyed to required colour and shade with necessary screws etc. complete.
9.102 each 47.55 5586.00 265614.30

Providing and fixing bright finished brass 100 mm mortice latch and lock ISI marked with six levers and a pair of
anodised (anodic coating not less than grade AC 10 as per IS : 1868) aluminium lever handles with necessary
93 9.103 screws etc. complete (Best make of approved quality). each 435.90 10.00 4359.00

Providing and fixing magnetic catcher in cupboard / ward robe shutters including fixing with necessary screws
94 9.114 etc. complete (Best make of approved quality. 0.00 0.00 0.00

9.114.2 Double strip (horizontal type). each 14.65 2860.00 41899.00


Providing and fixing factory made UPVC door frame made of UPVC profile section having an overall dimension
as below (tolerance ± 1mm) with wall thickness 2.0mm ± 0.2mm, corners of the door frame to be mitred and
welded of plastic, galvanized brackets and stainless steel screws. The hinge side vertical of the frames
reinforced by galvanized M.S. tube of size 19 X 19mm and 1mm ± 0.1mm wall thickness and 3 nos. stainless
steel hinges fixed to the frame complete as per manufacturers specification and direction of Engineer-in-charge
95 9.117 0.00 0.00 0.00

14 of 242
Balance work for Construction of ESIC Medical College and Hospital at Bihta ,Patna(Bihar)

Civil & Plumbing Work


Quantity Amount
S. No. Item Code Item of Work Unit Rate Remarks
DSR Non DSR DSR Non DSR
1 2 3 4 5 6 7 8 9 10
9.117.1 Extruded section Profile size 48x40 mm. metre 0.00 0.00
9.117.2 Extruded section Profile size 42x50 mm. metre 0.00 0.00

Providing and fixing cup board shutters 25mm thick, with Pre-laminated flat pressed three layer particle board
or graded wood particle board IS: 12823 marked exterior grade (Grade l Type ll) having one side decorative
lamination and other side balancing lamination including IInd class teak wood lipping of 25mm wide x12 mm
96 9.129 thick with necessary screws and bright finished stainless steel piano hinges complete as per direction of the sqm 1103.00 20.00 22060.00
Engineer-in-Charge.

Providing and fixing Two Hours Rated fire proof steel door with steel frame certified by CPRI for stability ,
integrity and insulation confirming to IS 3614 PART II WITH DOOR FRAME, confirming to IS 277 with frame
profile 140 x 65mm single rebate fabricated with provision of 4nos anchor bolt fasteners on each vertical jamb
to fix to wall/ RCC surface, anchor bolt shall be of M12x 80mm duly galvanized, 3mm thk base plate pre
punched & pre drilled hinge plate welded or rigidly fixed together by mechanical means. Frames shall be
fabricated at factory, bolted at top jamb for direct installation at site. All cut out including hinge plates, strike
97 NSI plate shall have mortar guard cover to prevent cement, dust ingress into cutouts. The Door frame shall be 0.00 0.00 0.00
suitably cleaned and primed with zinc phosphate stoving primer and finished with thermosetting polyurethane
paint. p y p

The shutters shall be of pressed steel.Fully flushed double skin door have interlock seam arrangements at stile
edges. The infill material is proprietory heat insulating material suitable for fire stability, integrity and insulation
rating. Shutters have 18mm x 3mm shielded intumscentstrip on three edges except the bottom. Shutters are
fabricated in factory with pre punched cutouts and reinforments to recieve ironmongery. Shutters have pre dilled
hinge plates with hinge guard covers, concealed lock box with lock fixing brackets and pre tapped holes.
Shutters are suitably cleaned and primed with zinc phosphate primer and finished with thermosetting 0.00 0.00 0.00
polyurethane paint .

NSI SINGLE LEAF DOOR (1200 X 2100mm) Sqm 7371.00 0.00 0.00 0.00

Supply & Fixing of polyester Powder Coated punch windows, including Providing & fixing of glass, all complete
as specified/ approved by the architect/structural consultant. Rate also includes sealing joints with sillcon
sealant wherever required.Average aluminium per sq.m- 4.5kg/sp.m)
98 NSI Sqm 2675.00 10.00 0.00 26750.00

0.00
Supply & Fixing of polyester Powder Coated strip windows, including Providing & fixing of glass, all complete as
specified/ approved by the architect/structural consultant. Rate also includes sealing joints with sillcon sealant
wherever required. Average aluminium per sq.m- 4.5kg/sp.m)
99 NSI Sqm 2875.00 5.00 0.00 14375.00

0.00
Supply & Fixing of polyester Powder Coated Unitized Structural Curtain wall glazing including cost of aluminium
flashing to the curtain all,including fixing of glass, all complete as specified/ approved by the architect/structural
consultant. Rate also includes sealing joints with sillcon sealant wherever required. Average aluminium per
100 NSI Sqm 4500.00 12501.00 0.00 56254500.00
sq.m-4.5kg/sp.m)

0.00
Providing & fixing of 12mm thick clear toughened glass with polished edges for Glass facade fixed with spider
fitting along with CSB M12 The Bolts. glasses to be supported with necessary Glass fins the perimeter of the
101 NSI facade to be fixed with anodized aluminium channels of required size (Average per Sqm -0.162 kg/ sqm) &filled Sqm 4500.00 2500.00 0.00 11250000.00
with sillcone

0.00

15 of 242
Balance work for Construction of ESIC Medical College and Hospital at Bihta ,Patna(Bihar)

Civil & Plumbing Work


Quantity Amount
S. No. Item Code Item of Work Unit Rate Remarks
DSR Non DSR DSR Non DSR
1 2 3 4 5 6 7 8 9 10
providing and fixing middle duty SS corner guards of SS angles complete with all hardwares fittings.
102 NSI Rmtr 3600.00 1064.00 0.00 3830400.00

0.00
providing and fixing wooden stretcher guard/ crash barrier with 2 nos. continous SS inserts fixed to wall at
intermediate distances including fixing arrangement ,melamine polish complete. 14952000.00
103 NSI Rmtr 4450.00 3360.00 0.00
0.00
wall tile cladding in extruded Vitrified clay tiles of size 230mm x 75mm
104 NSI sqm 1200.00 8818.00 0.00 10581600.00

0.00
supply and fixing of 4 mm thick solid color Non fire rated ACP of approved shade and make with necessary
105 NSI Back up over wall sqm 3200.00 14258.00 0.00 45625600.00

TOTAL W O O D A N D P. V. C. W O R K 0.00 30483603.15 142535225.00

STEELWORK 0.00
Structural steel work rivetted,bolted or welded in built up section trusses and framed work including
cutting,hoisting,fixing in position and applying a priming coat of approved steel primer all complete
106 10.2 Kg 46.35 72073.26 3340595.65

Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2mm and braced with flat
iron diagonals 20x5mm size with top and bottom rail of Tiron 40x40x6mm with 40mm dia, steel pulleys
complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of
107 10.3 approved steel primer. sqm 2592.70 25.00 64817.50

Supplying and fixing rolling shutters of approved make, g g pp made of required size M.S. laths interlocked
together through their entire length and jointed together at the end by end locks mounted on specially designed
pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull
108 10.6 operation complete including the cost of providing and fixing necessary 27.5cm long wire springs grade No.2 0.00 0.00 0.00
and M.S. top cover of required thickness for rolling shutters.

10.6.1 80x1.25mm M.S. laths with 1.25 mm thick top cover. sqm 1208.45 486.00 587306.70

109 10.7 Providing and fixing ball bearing for rolling shutters. each 356.50 202.00 72013.00

Extra for providing mechanical device chain and crank


110 10.8 operation for operating rolling shutters. 0.00 0.00 0.00

10.8.1 Exceeding 10.00 sqm and upto 16.80 sqm in the area. sqm 480.30 480.00 230544.00

Fixing standard steel glazed doors, windows and ventilators in walls with 15x3mm lugs 10 cm long embedded
in cement concrete blocks 15x10x10cm of 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm
nominal size) or with wooden plugs and screws or rawl plugs and screws or with fixing clips or with bolts and
nuts as required, including fixing of float glass panes with glazing clips and special metal-sash putty of
approved make, or metal beading with screws (only steel windows with lugs, glass panes cut to size and
111 10.10 glazing clips or metal beading with screws, shall be supplied by department free of cost.) kg 23.20 100.00 2320.00

16 of 242
Balance work for Construction of ESIC Medical College and Hospital at Bihta ,Patna(Bihar)

Civil & Plumbing Work


Quantity Amount
S. No. Item Code Item of Work Unit Rate Remarks
DSR Non DSR DSR Non DSR
1 2 3 4 5 6 7 8 9 10
Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators side /top /centre hung
with beading and all members such as K11 B and K12 B etc. complete of standard rolled steel sections, joints
mitred and flash butt welded and sash bars tenoned and rivetted with 15x3mm lugs, 10cm long, embedded in
cement concrete blocks 15x10x10cm of 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm
nominal size) or with wooden plugs and screws or rawl plugs and screws or with fixing clips or with bolts and
nuts as required, including providing and fixing of hinges, pivots, float glass panes with glazing clips and special
112 10.11. metal sash putty of approved make and a priming coat of approved steel primer excluding the cost of metal kg 178.90 100.00 17890.00
beading and other fittings except necessary hinges or pivots complete asper approved design.

Extra for providing and fixing steel beading of approved shape and section with screws instead of glazing clips
113 10.12 and metal sash putty in steel doors, windows, ventilators and composite units. metre 21.45 50.00 1072.50

Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred
and welded with 15x3 mm lugs 10cm long embedded in cement concrete blocks 15x10x10 cm of 1:3:6 (1
114 10.13 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) or with wooden plugs and screws or kg 51.15 18512.00 946888.80
with dash fastener or rawl plugs and screws or with fixing clips or with bolts and nuts as require including fixing
of necessary butt hinges and screws and applying a priming coat of approved steel primer.

Providing and fixing pressed steel door frames confirming to IS: 4351 manufactured from commercial mild steel
sheet of 1.25 mm thickness including hinges jamb, lock jamb, bead and if required angle threshold of mild steel
angle of section 50x25mm, or base ties of 1.25mm pressed mild steel welded or rigidly fixed together by
mechanical means, adjustable lugs with split end tail to each jamb including steel butt hinges 2.5mm thick with
mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer
115 10.14 after pre-treatment of the surface as directed by Engineerin- charge: 0.00 0.00 0.00

10.14.1 Profile B metre 251.90 3843.10 968076.89


10.14.2 Profile C metre 271.65 346.60 94153.89
10.14.3 Profile E metre 303.00 13363.38 4049104.14

Steel work in built up tubular trusses including cutting, hoisting fixing in position and applying a priming coat of
approved steel primer, welded and bolted including special shaped washers etc. complete.
116 10.16 0.00 0.00 0.00

10.16.1 Hot finished welded type tubes kg 61.50 55000.00 3382500.00

Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp of internal dia 140mm,
73mm height, top lid of 1.5mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be
screwed into the cast iron/ M.S. sheet box by means of 3.3mm dia. round headed screws, one lock at the
117 10.18 corners. Clamp shall be made of 12mm dia M.S. bar bent to shape as per standard drawing. each 81.20 5072.00 411846.40

Providing and fixing M.S. round holding down bolts with nuts and washer plates complete.
118 10.19 kg 52.05 31620.00 1645821.00

Providing and fixing bright finished brass casement window fasteners or peg stays to windows/ ventilators with
119 10.23 necessary welding and machine screws etc. complete. kg 226.05 38.00 8589.90

17 of 242
Balance work for Construction of ESIC Medical College and Hospital at Bihta ,Patna(Bihar)

Civil & Plumbing Work


Quantity Amount
S. No. Item Code Item of Work Unit Rate Remarks
DSR Non DSR DSR Non DSR
1 2 3 4 5 6 7 8 9 10
Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a
priming coat of approved steel primer using structural steel etc. as required.
120 10.25 0.00 0.00 0.00

In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.
10.25.2 kg 51.20 26731.35 1368645.12

Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing and
121 10.26 staircase railing including applying a priming coat of approved steel primer. 0.00 0.00 0.00

10.26.1 M.S. tube. kg 62.35 20450.00 1275057.50

Providing & fixing stainless steel hand rail, fixed from side including the cost of brackets and fixing with help of
appropriate dash fasteners , made up of s.s. 50 mm dia pipe of gauge of 304 grade supported over 40 mm
dia .pipe balusters of 14 guge of 304 grade fixed on s.s brackets including fixing of 10 mm thick thoughhened
glass to s.s. clips , welded to balusters and with help of necessary s.s. nuts & bolt all complete.after welding
122 NSI proper grinding and buffing shall be done to match other members .height of railing shall be 900 from finished Mtr 6725.00 100.00 0.00 672500.00
floor level / tread level . all stainless steel used shall have 7% - 8% nickle.

TOTAL STEEL WORK 0.00 18467242.99 672500.00


FLOORING 0.00
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating
coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. complete.
123 11.3 0.00 0.00 0.00

11.3.1 40mm thick with 20mm nominal size stone aggregate. sqm 192.95 6935.64 1338231.94

52 mm thick cement concrete flooring with concrete hardener topping under layer 40 mm thick cement concrete
1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick
124 11.4 cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) sqm 286.55 3996.21 1145114.92
by volume .hardening compound is mixed @ 2 litre per 50kg of cement or as per manufacturers specifications.
This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.

62 mm thick cement concrete flooring with concrete hardener topping under layer 50 mm thick cement concrete
1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick
cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6mm nominal size)
by volume. Hardening compound is mixed @ 2 litre per 50kg of cement or as per manufactures specifications.
125 11.5 This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. sqm 318.65 500.00 159325.00

Cement plaster skirting (upto 30 cm height) with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a
126 11.6 floating coat of neat cement. 0.00 0.00 0.00

11.6.1 18 mm thick. sqm 168.50 36.00 6066.00

Cement concrete pavement with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal
127 11.7 size) including finishing complete. cum 3695.95 10.00 36959.50

18 of 242
Balance work for Construction of ESIC Medical College and Hospital at Bihta ,Patna(Bihar)

Civil & Plumbing Work


Quantity Amount
S. No. Item Code Item of Work Unit Rate Remarks
DSR Non DSR DSR Non DSR
1 2 3 4 5 6 7 8 9 10
Extra for making chequers of approved pattern on cement concrete floors, steps, landing, pavements etc.
128 11.8 sqm 13.15 10.00 131.50

40 mm thick marble chips flooring rubbed and polished to granolithic finish, under layer 34 mm thick cement
concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5mm nominal size) and top layer 6mm
thick with white, black, chocolate, grey, yellow or green marble chips of sizes from 1mm to 4mm nominal size
laid in cement marble powder mix 3:1 (3 cement : 1 marble powder) by weight in proportion of 4:7 (4 cement
129 11.9 marble powder mix : 7 marble chips) by volume including cement slurry etc. complete : 0.00 0.00 0.00

11.9.3 Medium shade pigment with 50% white cement and 50% ordinary cement. sqm 319.00 10.00 3190.00

Marble chips skirting (upto 30 cm height) rubbed and polished to granolithic finish, top layer 6 mm thick with
white, black, chocolate, grey, yellow or green marble chips of sizes from smallest to 4 mm nominal size laid in
cement marble powder mix 3:1 (3 cement : 1 marble powder) by weight in proportion of 4:7 (4 cement marble
130 11.12 powder mix : 7 marble chips) by volume : 0.00 0.00 0.00

18 mm thick with under layer 12 mm thick in cement plaster 1:3 (1 cement : 3 coarse sand) :
11.12.1 0.00 0.00 0.00

Medium shade pigment with 50% white cement and 50% ordinary cement.
11.12.1.3 sqm 374.15 10.00 3741.50

Providing and fixing glass strips in joints of terrazo/ cement concrete floors.
131 11.13 0.00 0.00 0.00

11.13.1 40 mm wide and 4 mm thick. metre 17.60 8.00 140.80

Chequered terrazo tiles 22 mm thick with graded marble chips of size up to 6 mm in floors jointed with neat
132 11.19 cement slurry mixed with pigment to match the shade of the tiles including rubbing and polishing complete on 0.00 0.00 0.00
20 mm thick bed of cement mortar 1:4 (1 cement :4 coarse sand)
11.19.4 Ordinary cement without any pigment. sqm 467.55 10.00 4675.50

Tile work in skirting,risers of steps and dado ( upto 2 m height ) over 12 mm thick bed of cement mortar 1:3 ( 1
cement :3 coarse sand ) and jointed with grey cement slurry @ 3.3 kg/sqm including pointing in white cement
mixed with pigment of matching shade complete
133 11.22 0.00 0.00 0.00

11.22.1 Marble tiles (polished )Raj Nagar 0.00 0.00 0.00


11.22.1.1 8 mm thick sqm 570.40 10.00 5704.00

Marble stone flooring with 18mm thick marble stone (sample of marble shall be approved by Eng-in-charge)
over 20mm (average) thick base of cement mortar 1:4 (1 cement :4 coarse sand) laid and jointed with grey
134 11.23 cement slurry including rubbing and polishing complete with: 0.00 0.00 0.00

11.23.2 Raj nagar plain sqm 892.15 1039.44 927339.63


11.23.3 Agaria White sqm 1673.55 100.00 167355.00
11.23.5 Udaipur green marble sqm 1112.55 749.92 834323.50

135 11.24 Extra for pre-finished nosing to treads of steps of marble stone metre 105.20 2074.00 218184.80

Extra for marble stone flooring in treads of steps and risers using single length upto 2.00 metres
136 11.25 sqm 122.35 911.94 111575.86

19 of 242
Balance work for Construction of ESIC Medical College and Hospital at Bihta ,Patna(Bihar)

Civil & Plumbing Work


Quantity Amount
S. No. Item Code Item of Work Unit Rate Remarks
DSR Non DSR DSR Non DSR
1 2 3 4 5 6 7 8 9 10
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed
137 11.26 with pigment to match the shade of the slab including rubbing and polishing complete with base of cement 0.00 0.00 0.00
mortar 1 : 4 (1 cement : 4 coarse sand) :
11.26.1 25 mm thick. sqm 694.40 21090.00 14644896.00

Kota stone slabs 25 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement
138 11.27 mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the sqm 676.75 1433.14 969877.50
shade of the slabs, including rubbing and polishing complete.

38mm thick wood block flooring of first class teak wood laid over 25mm thick levelling layer of cement concrete
1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 10mm nominal size) to be paid separately coated
with a thin layer of hot bitumen (blown type) @ 2.45 kg per sqm. including fixing blocks in position after dipping
139 11.34 in hot bitumen (blown type) upto half depth, planed, levelled smooth and finished complete. sqm 3528.10 100.00 352810.00

Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by
the manufacture ) of approved make in all colours, shades except burgundy, bottle green, black of any size as
approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar
140 11.36 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white sqm 556.60 45054.03 25077071.62
cement mixed with pigment of matching shade complete.

Providing and laying ceramic glazed floor tiles (thickness to be specified by the manufacturer) of 1st quality
conforming to IS:15622 of approved make in colours such as white, ivory, grey, fume red brown laid on 20 mm
141 11.37 thick cement mortar 1:4 (1 cement: 4 coarse sand) including pointing the joints with white cement and matching sqm 598.65 2987.93 1788724.29
pigment etc. complete.

Providing and laying rectified Glazed Ceramic floor tiles 300x300 mm or more (thickness to be specified by the
manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours White, Ivory, Grey, Fume
Red Brown, laid on 20mm thick cement mortar 1:4 (1 Cement :
4 Coarse sand) including grouting the joints with white cement and matching pigments etc., complete.
142 11.39 sqm 759.90 9375.48 7124427.25

Providing and laying rectified Glazed Ceramic floor tiles 300x300 mm or more (thickness to be specified by the
manufacturer) of 1st quality conforming to IS : 15622 of approved make in all colours, shades, except White,
Ivory, Grey, Fume Red Brown, laid on 20 mm thick CementMortar 1:4 (1 Cement : 4 Coarse sand) including
143 11.40 pointing the joints with white cement and matching pigments etc., complete. sqm 800.40 50.00 40020.00

Providing and laying polished vitrified floor tiles in different sizes (thickness to be specified by the manufacturer)
with water absorption's less than 0.08% and conforming to IS : 15622 of approved make in all colours and
shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with
144 11.41 white cement and matching pigments etc., complete. 0.00 0.00 0.00

11.41.1 Size of Tile 50x50 cm sqm 966.35 100.00 96635.00


11.41.2 Size of Tile 60x60 cm sqm 1031.85 16800.78 17335884.84
11.41.3 Size of Tile 80x80 cm sqm 1478.30 50.00 73915.00

Fixing glazed/ Ceramic/ Vitrified floor tiles with cement based high polymer modified quick-set tile adhesive
145 11.43 sqm 224.70 500.00 112350.00
(Water based) conforming to IS: 15477 , using 5kg. adhesive per sqm of tile area, in average 3mm thickness.

20 of 242
Balance work for Construction of ESIC Medical College and Hospital at Bihta ,Patna(Bihar)

Civil & Plumbing Work


Quantity Amount
S. No. Item Code Item of Work Unit Rate Remarks
DSR Non DSR DSR Non DSR
1 2 3 4 5 6 7 8 9 10

providing and fixingflexible PVC sheet flooring with static dissipative properties and carbon content in 2.0mm
146 NSI thickness. it shall be homogeneous and monolayer in construction. the static dissipative properties must be Sqm 1872.00 1488.00 0.00 2785536.00
present throughout the full product thickness.(Equivalent to polyfloor Finessse EC.)

providing and fixing flocked textile floor covering of nylon 6.6 with resilliant water proof backing with thickness
4.3 mm and approximate weight of 1.8 kg / sqm . Satisfying relevant ISO tests as mentioned in specifications
147 NSI Sqm 2973.00 1613.00 0.00 4795449.00

TOTAL F L O O R I N G 0.00 72578670.96 7580985.00

ROOFING 0.00
Providing corrugated G.S. sheet roofing including vertical/ curved surface fixed with polymer coated J or L
hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled
with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of
sheets complete upto any pitch in horizontal/ vertical or curved surfaces) excluding the cost of purlins, rafters
148 12.1 0.00 0.00
and trusses and including cutting to size and shape wherever required.

12.1.1 1.00mm thick with zinc coating not less than 275gm/m² sqm 612.85 615.00 376902.75

Providing ridges or hips of width 60 cm over all width plain G.S. sheet fixed with polymer coated J or L hooks,
149 12.4 bolts and nuts 8 mm dia. G.I. limpet and bitumen washers complete. 0.00 0.00 0.00

12.4.1 0.80mm thick with zinc coating not less than 275gm/m² metre 313.60 29.00 9094.40

150 12.11 Extra for providing and fixing wind ties of 40x6 mm flat iron section metre 73.65 311.00 22905.15

Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10mm and
down gauge) including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design :
151 12.21 0.00 0.00 0.00

12.21.1 In 75x75mm deep chase metre 67.35 1082.00 72872.70

Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse
sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1mx1mx400micron, finished with
12mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement rounding the edge sand
152 12.22 each 108.00 431.00 46548.00
making and finishing the outlet complete.

Providing and fixing false ceiling with 12 mm thick plain/ semi perforated or with design ceiling tiles of BWP type
phenol formaldehyde synthetic resin bonded pressed particle board conforming to IS:3087 finished with a coat
of aluminium primer on both sides & edges and two coats of synthetic enamel paint of approved quality on
exposed face fixed to a grid made out of anodised aluminium (with 15 micron anodic coating) T-sections 35
x15x1.5 mm size main runners and cross runners 23.5x19x1.5 mm fixed to main runners placed 600 mm centre
to centre both ways so as to form a grid of 600 mm square. The frame work shall be suspended from ceiling by
level adjusting hangers of 6 mm dia M.S rod fixed to roof slab by means of ceiling cleats. The suspenders shall
153 12.29 be placed 600x 1200 mm centre to centre including fixing to the frame with C.P brace screws and applying a sqm 406.95 100.00 40695.00
priming coat of zinc chromate pp y g p g yellow primer ( aluminium frame work shall be paid separately.)

21 of 242
Balance work for Construction of ESIC Medical College and Hospital at Bihta ,Patna(Bihar)

Civil & Plumbing Work


Quantity Amount
S. No. Item Code Item of Work Unit Rate Remarks
DSR Non DSR DSR Non DSR
1 2 3 4 5 6 7 8 9 10
Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A
including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. (i) Single
154 12.41 socketed pipes 0.00 0.00 0.00

12.41.1 75 mm diameter metre 95.00 3930.00 373350.00


.12.41.2 110 mm diameter metre 163.40 8139.00 1329912.60

Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC
155 12.42 rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 0.00 0.00 0.00
leaving 10 mm gap for thermal expansion.
12.42.1 Coupler 0.00 0.00 0.00
12.42.1.1 75 mm each 81.40 256.00 20838.40
12.42.1.2 110 mm each 101.65 496.00 50418.40
12.42.4 Single tee without door 0.00 0.00 0.00
12.42.4.1 75x75x75 mm each 157.70 488.00 76957.60
12.42.5 Bend 87.5° 0.00 0.00 0.00
12.42.5.1 75 mm bend each 88.40 640.00 56576.00
12.42.5.2 110 mm bend each 134.20 185.00 24827.00
12.42.6 Shoe (Plain) 0.00 0.00 0.00
12.42.6.1 75 mm Shoe each 152.25 150.00 22837.50
12.42.6.2 110 mm Shoe each 263.10 345.00 90769.50

Providing and fixing Unplasticised -PVC pipe clips of approved design to Unplasticised - PVC rain water pipes
by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick
156 12.43 work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 0.00 0.00 0.00

12.43.1 75 mm each 79.50 1330.00 105735.00


12.43.2 110 mm each 96.90 1688.00 163567.20

Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm.diameter and weighing not less
157 12.44 than 440 grams. each 23.40 971.00 22721.40

Providing and fixing at all height false ceiling including providing and fixing of frame work made of special
sections power pressed from M.S. sheet and galvanised in accordance with zinc coating of grade 350 as per
IS : 277 and consisting of angle cleats of size 25mm wide x 1.6mm thick with flanges of 22mm and 37mm at
1200mm centre to centre one flange fixed to the ceiling with dash fastener 12.5mm diax40mm long with 6mm
dia bolts to the angle hangers of 25x25x0.55mm of required length, and other end of angle hanger being fixed
with nut and bolts to G.I. channels 45x15x0.9mm running at the rate of 1200mm centre to centre to which the
ceiling section 0.5mm thick button wedge of 80mm with tapered flanges of 26mm each having clips of 10.5mm
158 12.45 at 450mm centre to centre shall be fixed in a direction perpendicular to G.I. channel with connecting clips 0.00 0.00 0.00
made out of 2.64mm diax230mm long G.I. g p g wire at every junction including fixing the gypsum board with
ceiling section and perimeter

channels 0.5mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to
wall/partition with the help of rawl plugs at 450mm centre to centre with 25mm long drive-all screws @ 230mm
interval including jointing and fixing to a flush finish of tapered and square edges of the board with
recommended filler, jointing tapes, finisher and two coats of primer suitable for board as per manufactures
specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with
frame of perimeter channels suitably fixed all complete as per drawing and specification and direction of the 0.00 0.00 0.00
Engineer in Charge but excluding the cost of painting with :

22 of 242
Balance work for Construction of ESIC Medical College and Hospital at Bihta ,Patna(Bihar)

Civil & Plumbing Work


Quantity Amount
S. No. Item Code Item of Work Unit Rate Remarks
DSR Non DSR DSR Non DSR
1 2 3 4 5 6 7 8 9 10
12.5 mm thick tapered edge gypsum board conforming to IS: 2095- Part I,
12.45.1 sqm 502.10 39676.00 19921319.60

Providing and fixing to the inlet mouth of rain water pipe PTMT (an Engineering Thermoplastic) grating square
(Slit) 150 mm square with a height of 8 mm and weighing not less than 100 gms.
159 12.46 each 86.15 60.00 5169.00

Providing & fixing UV stabilised fiberglass rerinforced plastic sheet rooring up to any pitch including fixing with
polymer coated J or L hooks bolts & nuts 8mm dia GI plain/bitumen washers complete but excluding the cost of
purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating
minimum 0.3% Ultra-violet stabiliser in resin system under approximately 2400 psi and hot cured. They shall be
of uniform pigmentation and thickneww without air pockets and shall conform to IS 10192 and IS 12866 the
sheets shall be opaque or ranslucent, clear or pigmented textured or smooth as specified.
160 12.47 0.00 0.00 0.00

2mm thick currugated (2.5" or 4.2" or 6") or stepdown (2" or 3" or 6") as specified
12.47.1 sqm 785.35 1006.00 790062.10

Providing & fixing pressed clay tile (Mangalor tile) 20 mm nominal thickness and of approved size and as per
approved pattern ceiling on steel frame work complete (steel frame work to be paid separately)
161 12.48 sqm 209.40 152.00 31828.80

Providing & laying pressed clay tile ridge (Mangalore tile) of 20mm thickness of approved pattern ceiling over
162 12.49 steel frame work complete (steel frame work to be paid separately) sqm 105.00 50.00 5250.00

P/f of precoated galvanized iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-
incharge) 0.50 mm +/- 5% total coated thickness (TCT), Zinc coating 120gsm as per IS: 277 in 240mpa steel
grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should
have protective guard film of 25 microns minimum to avoid scratches while transportation and should be
163 12.5 supplied in single length upto 12 metre or as desired by Engineer-incharge. The sheet shall be fixed using self
drilling /self tapping screws of size (5.5x 55mm) with EPDM seal or with polymer coated J or L hooks, bolts and
nuts 8mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead
complete upto any pitch in horizontal/ vertical or curved surfaces excluding the cost of purlins, rafters and
trusses and including cutting p gg to size and shape wherever required.

sqm 440.65 15324.00 6752520.60

Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm +/- 5% total coated
thickness (TCT), Zinc coating 120gsm as per IS: 277 in 240mpa steel grade, 5-7 microns epoxy primer on both
side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws or with polymer
coated J or L hooks, bolts and nuts and or G.I. seam bolts and nuts, G.I. plain and bitumen washers complete
164 12.51 0.00 0.00 0.00

12.51.1 Ridges plain (500 - 600mm). metre 458.15 812.00 372017.80


12.51.2 Flashings/ Aprons.( Upto 600 mm) metre 448.15 28.00 12548.20
12.51.6 Gutter .(600 mm over all girth). metre 547.80 74.00 40537.20

23 of 242
Balance work for Construction of ESIC Medical College and Hospital at Bihta ,Patna(Bihar)

Civil & Plumbing Work


Quantity Amount
S. No. Item Code Item of Work Unit Rate Remarks
DSR Non DSR DSR Non DSR
1 2 3 4 5 6 7 8 9 10
Providing and fixing False Ceiling Tiles of approved materials of size 595x595 mm in true horizontal level
suspended on inter locking metal grid of hot dipped galvanised steel sections ( galvanized @ 170 gsm/sqm.)
consisting of main "T" runner suitably spaced at joints to get required length and of size 24x38mm made from
0.30mm thick (minimum) sheet spaced at 1200mm center to center and cross "T" of size 24x25mm made
of .30mm thick (minimum) sheet, 1200mm long spaced between main "T" at 600mm center to center to form a
grid of 1200x600 mm and secondary cross "T" of length 600mm and size 24x25mm made of 0.30 mm thick
(minimum) sheet to be interlocked at middle of the 1200x600mm panel to form grids of 600x600mm and laying
165 12.52 false ceiling tiles of approved texture in the grid including, wherever, required, cutting/making, opening for 0.00 0.00 0.00
services like q g gp g diffusers, grills, light fittings, fixtures, smoke detectors etc.

Main "T" runners to be suspended from ceiling using GI slotted cleats fixed to ceiling with 6 mm dia and 50mm
long dash fasteners, 4mm GI adjustable rods with galvanised level clips spaced at 1200m center to center
along main T, bottom exposed width of 24mm of all Tsections shall be pre-painted with polyester paint, all
complete at all heights as per specifications drawings and as directed by Engineer-in-Charge. (The rate is sqm 256.55 4497.03 1153713.28
excluding cost of tiles which will be paid separately ).

TOTAL R O O F I N G 0.00 31992495.18 0.00

FINISHING 0.00
166 13.1 12 mm cement plaster of mix : 0.00 0.00
13.1.2 1:6 (1 cement : 6 fine sand) sqm 67.65 107493.25 7271918.67

167 13.2 15 mm cement plaster of mix : 0.00 0.00 0.00


13.2.2 1:6 (1 cement : 6 fine sand) sqm 78.55 19919.42 1564670.44

168 13.4 12 mm cement plaster of mix : 0.00 0.00 0.00

13.4.2 1:6 (1 cement : 6 coarse sand) sqm 72.70 50.00 3635.00

169 13.16 6 mm cement plaster of mix : 0.00 0.00 0.00

13.16.1 1:3 (1 cement : 3 fine sand) sqm 62.15 21416.00 1331004.40

Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m
170 13.22 or part thereof. sqm 16.80 22857.90 384012.71

Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface
171 13.26 even and smooth complete sqm 47.20 607977.00 28696514.40

172 13.27 Extra for lining out plaster to imitate stone or concrete blocks walling sqm 16.60 2030.00 33698.00

173 13.37 White washing with lime to give an even shade: 0.00 0.00 0.00
13.37.1 New work (three or more coats) sqm 6.75 22420.00 151335.00

Distempering with dry distemper of approved brand and manufacture (two or more coats) and of required
shade on new work, over and including priming coat of whiting to give an even shade.
174 13.40 sqm 26.30 1875.00 49312.50

Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade
175 13.41 0.00 0.00 0.00

24 of 242
Balance work for Construction of ESIC Medical College and Hospital at Bihta ,Patna(Bihar)

Civil & Plumbing Work


Quantity Amount
S. No. Item Code Item of Work Unit Rate Remarks
DSR Non DSR DSR Non DSR
1 2 3 4 5 6 7 8 9 10
New work (two or more coats) over and including priming coat with cement primer.
13.41.1 sqm 41.55 178926.71 7434404.63

176 13.44 Finishing walls with water proofing cement paint of required shade : 0.00 0.00 0.00
13.44.1 New work(Two or more coats applied @3.84 kg/10 sqm) sqm 30.80 6284.00 193547.20

177 13.45 Finishing walls with textured exterior paint of required shade : 0.00 0.00 0.00
New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including base coat of water proofing
13.45.1 cement paint applied @ 2.20kg/10 sqm. sqm 96.25 41431.00 3987733.75

178 13.46 Finishing walls with Acrylic Smooth exterior paint of required shade : 0.00 0.00 0.00
New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including base coat of water proofing cement
13.46.1 paint applied @ 2.20 kg/ 10 sqm). sqm 50.40 50.00 2520.00

Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade
179 13.47 0.00 0.00 0.00

New work (Two or more coats applied @ 1.43 ltr/ 10 sqm. over and including base coat of water proofing
13.47.1 cement paint applied @ 2.20 kg/ 10 qm). sqm 60.10 56514.00 3396491.40

Finishing walls with Deluxe Multi surface paint system for interiors and exteriors using Primer as per
180 13.48 manufacturers specifications : 0.00 0.00 0.00
Two or more coats applied @ 1.25 ltr/10 sum. over and including one coat of Special primer applied @ 0.75 ltr /
10 sum.
13.48.1 sqm 62.25 13397.00 833963.25

Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @0.90 ltr/10
sum over an under coat of primer applied @0.75 ltr/ 10 sum of approved brand or manufacture
13.48.2 sqm 51.55 50.00 2577.50

Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @0.90
ltr/10 sum over an under coat of primer applied @ 0.80 ltr/ 10 sum of approved brand or manufacture
13.48.3 sqm 53.35 1084.00 57831.40

181 13.50 Applying priming coat : 0.00 0.00 0.00


With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood)
13.50.1 sqm 16.55 29124.00 482002.20
With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised
13.50.3 iron/steel works sqm 12.65 5328.00 67399.20

Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's
specifications including appropriate riming coat, preparation of surface, etc. complete.
182 13.52 0.00 0.00 0.00

13.52.2 On concrete work sqm 77.75 100.00 7775.00

Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade:
183 13.60 0.00 0.00 0.00

Two or more coats on new work


13.60.1 sqm 40.05 28080.81 1124636.44

Painting with synthetic enamel paint of approved brand and manufacture to give an even shade
184 13.61 0.00 0.00 0.00

25 of 242
Balance work for Construction of ESIC Medical College and Hospital at Bihta ,Patna(Bihar)

Civil & Plumbing Work


Quantity Amount
S. No. Item Code Item of Work Unit Rate Remarks
DSR Non DSR DSR Non DSR
1 2 3 4 5 6 7 8 9 10
13.61.1 Two or more coats on new work sqm 35.35 10000.00 353500.00

Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even
185 13.62 shade: 0.00 0.00 0.00
Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and
13.62.1 manufacture. sqm 51.30 42625.00 2186662.50

Washed stone grit plaster on exterior walls of height upto 10 M. above level in two layers, under layer 12mm
cement laster 1:4 (1 cement : 4 coarse sand ) furrowing the under layer with scratching tool, applying cement
slurry on the under layer @ 2 Kg of cement per square metre, top layer 15mm cement plaster 1:1/2:2 (1 cement
: 1/2 coarse sand : 2 stone chipping 10mm nominal size) in panels with groove all around as per approved
pattern including scrubbing and washing, the top layer with brushes and water to expose the stone
186 13.72 chippings ,complete as per specification and direction of Engineer-in- charge (Payment for providing grooves sqm 262.20 100.00 26220.00
shall be made separately).

Forming groove of uniform size in the top layer of washed stone grit plaster as per approved pattern using
wooden battens, nailed to the under layer including removal of wooden battens, repair to the edges of panels
187 13.73 and finishing the groove complete as per specifications and direction of the Engineer-in-charge : 0.00 0.00 0.00

13.73.1 15 mm wide and 15 mm deep groove metre 13.30 100.00 1330.00

Extra for washed grit plaster on exterior walls of height more than 10m from ground level for every additional
188 13.74 height of 3 m or part thereof. sqm 40.75 100.00 4075.00

Providing & fixing 10mm thick dove tailed tiles with grooves on rear side. Made from special Vitrified Clay.
189 sqm 1200.00 100.00 0.00 120000.00
NSI

TOTAL F I N I S H I N G 59648770.60 120000.00

ROAD WORK 0.00


Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating
earth to an average of 22.5 cm. depth, dressing to camber and consolidating with road roller including making
190 16.1 good the undulations etc. and re-rolling the sub grade and disposal of surplus earth lead upto 50 metres. sqm 33.90 16070.00 544773.00

191 16.3 Supplying and stacking at site. 0.00 0.00


16.3.1 90 mm to 45 mm size stone aggregate. cum 742.30 3173.67 2355815.24
16.3.2 63 mm to 45 mm size stone aggregate. cum 768.45 1827.00 1403958.15
16.3.7 Stone screening 11.2 mm nominal size (Type B). cum 979.40 343.60 336521.84

Laying , spreading and compacting stone aggregate of specified sizes to WBM specifications including
spreading in uniform thickness, hand picking , rolling with 3 wheeled road / vibratory roller 8-10 tonne in stages
to proper grade and camber, applying and brooming requisite type of screening / binding material to fill up
192 16.4 interstices of coarse aggregate watering and compacting to the required density cum 192.55 9346.06 1799583.85

Laying & spreading brick aggregate (jhama) of size 90mm to 45mm , earth etc. including screening, sorting and
193 16.5.2 spreading to template and consolidation etc. complete.with cum 136.20 30.00 4086.00

26 of 242
Balance work for Construction of ESIC Medical College and Hospital at Bihta ,Patna(Bihar)

Civil & Plumbing Work


Quantity Amount
S. No. Item Code Item of Work Unit Rate Remarks
DSR Non DSR DSR Non DSR
1 2 3 4 5 6 7 8 9 10
Providing and laying design mix cement concrete in roads, taxi tracks and runways having a minimum works
test beam flexural strength of 30 kg. per cm² at 28 days using not less than 340 Kg. of cement per cum of
finished concrete, coarse sand and graded stone aggregate of 40mm nominal size in appropriate proportions as
per specified design criteria approved by Engineer-in-charge mechanically vibrated using needle and surface
vibrators including steel form work with sturdy M. S. channel sections including curing and providing and filling
construction joints and dummy joints with approved joint filler and primer including rounding of the edges and
194 16.43 filling the grooves 10x25mm deep at top for construction joints and 10mmx50mm deep at top for dummy joints cum 3692.40 6485.00 23945214.00
with joint sealing compound (conforming to grade B of IS : 1834) including making necessary arrangements for
expansion joints etc. all complete.

Manufacturing supplying and fixing retro reflective overhead signage boards made up of 2mm thick aluminium
sheet face to be fully covered with high intensity and encapsulated lens type heat activated retro reflective
sheeting conforming to type - III of ASTM-D-4956-01 as approved by Engineer-in-charge letters, borders etc. as
per IRC : 67-2001 in silver white with blue colour back ground and with high intensity grade, pasted on
substrate by pressure sensitive adhesive backing which shall be activated by applying pressure conforming to
class II of ASTM-D-4956-01 and fixing the same to the plate of structural frame work by means of suitable sized
aluminium alloys, rivets or bolts & nuts @ 300 mm centre to centre all along the periphery as well as in two
vertical rows alongwith theft resistant measures including the cost of painting with two or more coats of epoxy
195 16.60 paint in grey p g p yp g y colour on the back side of aluminium sheet including appropriate priming coat. The 0.00 0.00
rate includes the cost of rounding off the corners, lowering down the structural frame work from the gantry,
fixing and erecting the same in position all complete as per drawings, specification and

16.60.1 Overhead informatory road signage. sqm 4017.75 16268.00 65360757.00

Providing and laying and making kerb channel 30cm wide and 50mm thick of cement concrete 1:3:6 (1
cement:3 coarse sand:6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40
mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth
196 16.63 etc. complete and as per direction of Engineer-in-charge. metre 198.80 3037.00 603755.60

Providing and laying 60mm thick factory made cement concrete interlocking paver block of M -30 grade made
by block making machine with strong vibratory compaction and of approved size and design/ shape laid in
required colour and pattern over and including 50mm thick compacted bed of course sand, filling the joints with
197 16.68 coarse sand etc. all complete as per the direction of Engineer-in-charge. sqm 346.35 24508.00 4155883.41

TOTAL ROAD WORK 100510348.10 0.00


SANITARY INSTALLATION WORK
198 17.1 Providing & fixing of water closet squatting pan (indian type w.c.pan) with 100mm sand cast iron P or S trap, 10 liter low level white
p.v.c. flushing cistern with manually controlled device (handle lever)conforming to IS:7231,with all fittings and fixtures comlete
including cutting and making good the walls and floors wherever required:

17.1.1 White Vitreous china Orissa pattern W.C.pan of size 580x440mm with integral type foot rests. marked white solid plastic seat and lid.

Each 2304.65 578.00 1332087.70


0.00 0.00
199 17.3 Providing & fixing of white vitreous china pedestal type water closet(European type) with seat and lid, 10 liter low level white
viterous china flushing cistern C.P.flush bend with fittings & C.I.brackets ,40mm flush bend, overflow arrangment with specials of
standard make and mosquito proof coupling of approved municipala design complete including painting of fittings and brackets,
cutting and making good the wall and Floors wherever required:

0.00 0.00

27 of 242
Balance work for Construction of ESIC Medical College and Hospital at Bihta ,Patna(Bihar)

Civil & Plumbing Work


Quantity Amount
S. No. Item Code Item of Work Unit Rate Remarks
DSR Non DSR DSR Non DSR
1 2 3 4 5 6 7 8 9 10
17.3.1 W.C pan with ISI marked white solid plastic seat and lid
Each 3282.95 1014.00 3328911.30
0.00 0.00
200 17.7 Providing & fixing wash basin with C.I. brackets, C.P brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting
of fittings and brackets,cutting and making good the walls wherever required:

0.00 0.00
17.7.1 White Vitreous China Wash basin size 630x450mm with a pair of 15 mm C.P.brass pillar taps.

Each 1332.90 1187.00 1582152.30


0.00 0.00
201 17.10 Providing & fixing stainless steel A ISI 304(18/8) kitchen sink as per I.S 13983 with C.I. brackets and stainless steel plug 40 mm
including painting of fittings and brackets, cutting and making good the walls wherever required: Kitchen sink with drain board.

0.00 0.00
17.10.1.1 510x1040mm bowl depth 250mm Each 6154.35 70.00 430804.50
0.00 0.00
202 17.11 Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug 40mm C.P brass waste
and 40mm C.P. brass trap with necessary C.P. brass unions complete including painting of fittings and brackets, cutting and making
good the wall wherever required :

0.00 0.00
17.11.2 Size 600x450x200mm each 2300.95 39.00 89737.05
0.00 0.00
203 17.32 Providing & fixing mirror of superior glass(of aproved quality) and of required shape and size with plastic moulded frame of
approved make and shade with 6mm thick hard board backing: 0.00 0.00
17.32.2 Rectangular Shape 453x357mm Each 465.10 1823.00 847877.30
17.32.3 Oval shape 450x350 mm ( outer dia mentioned) Each 504.00 144.00 72576.00
17.32.4 Rectangular Shape 1500x450mm Each 1034.50 16.00 16552.00
0.00 0.00
0.00 0.00
204 17.71 Providing & fixing PTMT liquid soap container 109mm wide,125mm high and 112mm distance from wall of standard shape with
bracket of the same materials with snap fittings of approved quality and colour. weighing not less than 105 gms. Each 164.65 967.00 159216.55
0.00 0.00
205 17.73 Providing & fixing PTMT towel rail complete with brackets fixed to wooden cleats with C.P brass screws with concealed fitting
arangement of approved quality and colour.
0.00 0.00
17.73.2 600 mm long toil towel rail with total length of 645mm,width 78mm and effective height of 88mm, weighing not less than 190 gms.
Each 329.50 1316.00 433622.00
0.00 0.00
206 NSI Providing & fixing C.P. brass deodrant holder fixed to PVC rawl plug with C.P.brass screws complete.
Each 951.00 1645.00 0.00 1564395.00
207 NSI Providing & fixing 15mm dia C.P. brass angle valve with s.s mesh filter and c.p.cast brass wall flange with extension piece in required
length.
Each 800.00 6823.00 0.00 5458400.00
0.00 0.00 0.00
208 NSI Providing & fixing 15mm dia PVC connector 450mm long with connecting nuts (for connection to Mixers & tap from Angle Valve.
Each 194.00 6380.00 0.00 1237720.00
0.00 0.00 0.00
209 NSI Providing & fixing Recessed type S.S. Toilet paper holder including cutting and making good the walls. Each 1236.00 1250.00 0.00 1545000.00
0.00 0.00 0.00
210 NSI Providing & fixing C.P. brass twin coat hooks fixed on toilet door with C.P. brass screws. Each 687.00 1669.00 0.00 1146603.00
0.00 0.00 0.00
211 NSI Providing & fixing 15mm dia C.P. ablution health faucet with 1.0m long ss extension pipe with wall hookn and oprating knob
complete in all respect.
Each 1601.00 1250.00 0.00 2001250.00
212 NSI Providing & fixing solid state, no touch operating, fully hygenic hand drier of approved shade with blower, continuous repeat usage,
time deley, summer & winter control, music while drying, volume ON/OFF controls including providing necessary bracket cable from
drier to plug, plug top key & lock etc. complete as requried.
Each 9019.00 16.00 0.00 144304.00
0.00 0.00 0.00
213 NSI Providing & fixing C.P.brass kitchan sink mixer Tap with aerator complete as reqd.
Each 2144.00 503.00 0.00 1078432.00
0.00 0.00 0.00

28 of 242
Balance work for Construction of ESIC Medical College and Hospital at Bihta ,Patna(Bihar)

Civil & Plumbing Work


Quantity Amount
S. No. Item Code Item of Work Unit Rate Remarks
DSR Non DSR DSR Non DSR
1 2 3 4 5 6 7 8 9 10
214 NSI Providing & fixing C.P.shower fitting comprising of (all fixture of half turn fittings):- one overhead single floe shower with shower arm
and wall flange, Two concealed stopcocks with wall flange, one four way divertor, one bath spo with wall flange including cutting
and making good the walls where requiredi.e. installation, testing, & commissioning of sanitary fixtures as per above details
including all hardwares.

Each 5555.00 1044.00 0.00 5799420.00


0.00 0.00 0.00
215 NSI Providing & fixing C.P. brass single hole basin Mixer Tap with aerator complete as required.
Each 7513.00 1951.00 0.00 14657863.00
0.00 0.00 0.00
216 NSI Providing & fixing of white vitreous china floor mounting type Indian water closet with C.P.bolts, nuts, C.I. chair or other hanging
arrangements, Bakelite toilet seat and cover complete with all accessories.

Each 7926.00 30.00 0.00 237780.00


0.00 0.00 0.00
217 NSI Providing & fixing in position of white vitreous china below counter wash basin / circular / oval with C.I. brackets painted white, 32
mm dia C.P. brass waste, 32 mm dia C.P. cast brass bottle trap, including cutting and making good the walls and floors where
required.
Each 3692.00 100.00 0.00 369200.00
0.00 0.00 0.00
218 NSI Providing and fixing & painting, uPVC RWP pipes6Kg/cm2 (IS: 4985) including all fittings (plain or door) e.g. bends, junction, cowls,
offsets, access pieces, jointing with rubber ring/solvent cement joints including required suports&cutting chase or holes in walls
floors and making good where required.(for rain water pipe inside the building)

0.00 0.00 0.00


75 mm OD. Mtrs. 161.00 8694.00 0.00 1399734.00
110 mm OD Mtrs. 299.00 33668.00 0.00 10066732.00
160 mm OD Mtrs. 600.00 5849.00 0.00 3509400.00
200 mm OD Mtrs. 916.00 2560.00 0.00 2344960.00
0.00 0.00 0.00
219 NSI Providing and laying s&s cast spun pipe conforming to IS:1536 class LA including all fitting e.g.bends,tees,reducers,blank
flanges,45mm deep lead caulked joints and testing comlete in all respects including excavation,cutting chase or hole in walls and
floors and making good where required.

0.00 0.00 0.00


200 mm dia mtrs 2216.00 10.00 0.00 22160.00
0.00 0.00 0.00
220 NSI Providing & fixing in position uPVC P"or S" trap of self cleaning design of following sizes for the embedded areas. Making proper
connection with drip-seal joints, cutting chase / hole in floors /slabs and bringing the same in proper condition in cement concrete
1:2:4 mix complete as required. including cost of cutting and making good the walls and floors where required.

0.00 0.00 0.00


100 mm inlet and 100 mm outlet Each 329.00 2653.00 0.00 872837.00
100 mm inlet and 50 mm outlet (Floor Drains only) Each 274.00 1462.00 0.00 400588.00
0.00 0.00 0.00
221 NSI Providing and fixing G.I. pipes conforming to I:S including all fittings, testing, cutting holes or chases and making good where
required.
0.00 0.00 0.00
32mm Mtrs. 190.00 2507.00 0.00 476330.00
50mm Mtrs. 279.00 5005.00 0.00 1396395.00
222 NSI Providing and fixing cast bronze chrome plated grating with ring and stainless steel anti cockroch basket and two ss screw including
fixing to the floor with cement mortar. 0.00 0.00 0.00
175 mm dia Each 351.00 10.00 0.00 3510.00
223 NSI Providing and laying cement concrete 1:2:4 mix (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm and down gauge) 75
mm in bed and all round SCI / CILA / UPVC / GI pipes 0.00 0.00 0.00
150/100/75/50/40/32 mm dia soil & waste pipes under floor including shuttering and centering. Mtr. 440.00 50.00 0.00 22000.00
0.00 0.00 0.00
224 NSI Providing and fixing G.I. inlet fitting with maximum 3 inlets 32,40 or 50 mm size fabricated from 100/150 mm dia G.I. pipes and
welded G.I. sockets,fixed to C.I. trap with lead caulked joint and set in cement concrete as per standard drawing complete.

Each 1316.00 1482.00 0.00 1950312.00


0.00 0.00 0.00
225 NSI Painting G.I.pipes with two coats of bitumastic paint,wrapping with one layer of polythene tape and applying a final coat of
bitumastic paint.(for pipes in chase or under floors). 0.00 0.00 0.00
32 mm dia mtr 22.00 1863.00 0.00 40986.00
50 mm dia mtr 32.00 4205.00 0.00 134560.00

29 of 242
Balance work for Construction of ESIC Medical College and Hospital at Bihta ,Patna(Bihar)

Civil & Plumbing Work


Quantity Amount
S. No. Item Code Item of Work Unit Rate Remarks
DSR Non DSR DSR Non DSR
1 2 3 4 5 6 7 8 9 10
226 NSI Providing and fixing in position rainwater spout fabricated from GI (Medium class to IS:1239) pipe 80 mm dia, set in 1:2:4 cement
concrete (1 cement:2 coarse sand: 4 stone aggregate 40 mm nominal size) complete.

Each 521.00 2.00 0.00 1042.00


0.00 0.00 0.00
227 NSI Providing and fixing CI rainwater outlet fitting with aluminium ring and CI grating and aluminium dome fitting fixed with SS screws on
top of Rainwater downtake pipe at gutter/roof level.C.I.grating for basement drain point complete. 0.00 0.00 0.00
175 x175 mm
Each 2915.00 10.00 0.00 29150.00
0.00 0.00 0.00
228 NSI Providing and fixing cast brass cleanout plug( Ceiling or Floor) with suitable inset keys for opening, male threaded joint with socket
fixed to UPVC/SCI pipe complete in all respects. 0.00 0.00 0.00
100 mm nominal pipe size Each 806.00 750.00 0.00 604500.00
150 mm nominal pipe size Each 1045.00 35.00 0.00 36575.00
200 mm nominal pipe size Each 1686.00 36.00 0.00 60696.00
0.00 0.00 0.00
229 NSI Providing & fixing in position of white vitreous china large flat back waterless urinal commander Urimat complet with all
accessories. supported by CI/MS bracket including C.P. brass waste with dome type grating, C.P.cast brass bottle trap with extension
piece,wall flange, including cutting and making good the walls and floors where required.

Each 24820.00 10.00 0.00 248200.00


0.00 0.00 0.00
230 NSI Providing & fixing in position of white vitreous china large urinal partition with concealed C.I. Bracket including cutting and making
good the walls and floors where required.

Each 903.00 329.00 0.00 297087.00


SANITARY INSTALLATION WORK TOTAL 8293536.70 59158121.00

Water Supply Work


231 18.1 Providing, Fixing, Polythelene-Aluminium- Polyethelene (PE-AL-PE) composite pressure pipe conforming to IS-15450 U.V.Stablized
with carbon black having thermal stability for hot & cold water supply, capable to withstand temperature up to 80 deg.c including all
special fittings of composite material (engineering plastic blend and brass inserts wherever required) e.g.elbows, tees, reducers,
couplers & connectors etc.with clamps at 1 mtr. spacing. This includes the cost of cutting chases and including testing of joints
complete as per direction of the engineer in charge.

0.00
18.1.5 3240(40 mm OD)pipe Mtr 391.30 8686.00 3398831.80
18.1.6 4050(50 mm OD)pipe Mtr 507.60 1000.00 507600.00
18.2.2 1620(20 mm OD)pipe Mtr 260.85 33906.00 8844380.10
18.2.3 2025(25 mm OD)pipe Mtr 319.80 14714.00 4705537.20
18.2.4 2532(32 mm OD)pipe Mtr 413.30 12736.00 5263788.80
0.00 0.00
232 18.12 Providing and fixing G.I. Pipes complete with G.I. fittings and clamps,including cutting and making good the walls etc.(External work)

0.00 0.00
0.00 0.00
18.12.2 20 mm dia. pipes
Mtr 116.60 18.00 2098.80
18.12.6 50 mm dia pipes
Mtr 280.10 7415.00 2076941.50
18.12.7 65 mm dia pipes
Mtr 356.15 1999.00 711943.85
18.12.8 80 mm dia pipes
Mtr 458.15 1484.00 679894.60
0.00 0.00
233 18.18 Providing & fixing ball valve ( brass) of approved quality,High or low pressure, with plastic floats complete:-
0.00 0.00
18.18.1 15 mm dia nominal bore
Nos. 228.35 19.00 4338.65
18.18.2 20 mm dia nominal bore
Nos. 333.25 22.00 7331.50

30 of 242
Balance work for Construction of ESIC Medical College and Hospital at Bihta ,Patna(Bihar)

Civil & Plumbing Work


Quantity Amount
S. No. Item Code Item of Work Unit Rate Remarks
DSR Non DSR DSR Non DSR
1 2 3 4 5 6 7 8 9 10
18.18.3 25 mm dia nominal bore
Nos. 385.90 24.00 9261.60
0.00 0.00
18.27 Providing and laying S&S centrifugally cast (spun) iron pipes (Class LA) conforming to IS - 1536 : 0.00 0.00
18.27.1 100 mm dia. pipe metre 737.15 1630.00 1201554.50
18.27.3 150 mm dia. pipe metre 1066.65 870.00 927985.50
18.27.4 200 mm dia. pipe metre 1484.00 700.00 1038800.00
0.00 0.00
18.28 Providing lead caulked joints to spun iron or C.I. pipes and specials including testing of joints but excluding the cost of pig lead :
0.00 0.00
18.28.1 100 mm diameter pipe each 82.25 270.00 22207.50
18.28.3 150 mm diameter pipe each 123.30 145.00 17878.50
18.28.4 200 mm diameter pipe each 163.45 122.00 19940.90
0.00 0.00
234 18.40 Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality. 0.00 0.00
18.40.6 50 mm dia pipes RM 6.10 7415.00 45231.50
18.40.7 65 mm dia pipes
RM 7.50 1999.00 14992.50
18.40.8 80 mm dia pipes
RM 8.65 1484.00 12836.60
0.00 0.00
235 18.51 Providing & fixing C.P. brass (Long body)bib cock of approved quality conforming to IS standerd and weight not less then 690 gms.

0.00 0.00
18.51.1 15 mm nominal bore Each 315.80 722.00 228007.60
0.00 0.00
236 18.58 Providing and fixing PTMT grating of approved quality and colour.
0.00 0.00
18.58.1.1 100 mm nominal dia with 25 mm waste hole.
each 39.70 50.00 1985.00
18.58.1.2 125 mm nominal dia with 25 mm waste hole.
each 46.65 100.00 4665.00
0.00 0.00
237 18.60 Providing and fixing enclosed type water meter ( bulk type) conforming to IS: 2373 and tested by municipal Board complete with
bolts , nuts, rubber insertions etc. (The tail pieces if required will be paid separetely).

0.00 0.00
18.60.1 80 mm dia nominal bore No. 2448.40 12.00 29380.80

0.00 0.00
238 18.65 Providing & fixing PTMT soap dish Holder having length of 138mm,breadth 102mm, height of 75mm with concealed fitting
arrangements.Weighing not less than 106gms.
Each 133.30 1161.00 154761.30
0.00 0.00
0.00 0.00
239 NSI Providing and fixing G.I. Pipes complete with G.I. fittings and clamps , including cutting and making good the walls etc.(internal work
& External work)
0.00 0.00
100 mm dia nominal bore R .Mtr 726.00 5180.00 3760680.00
240 NSI Providing & fixing ball valve ( brass) of approved quality High or low pressure, with plastic floats complete:
0.00
32 mm dia Nos. 1210.00 233.00 281930.00
40 mm dia Nos. 1535.00 138.00 211830.00
50 mm dia Nos. 2313.00 431.00 996903.00
65 mm dia Nos. 7084.00 42.00 297528.00
0.00 0.00
241 NSI Providing & fixing minimum 6mm thick up to 15mm-40mm and minimum 9mm thick up to 50mm-100mm nitrile rubber insulation
on hot water pipes in side the building.

RM 170.00 8294.00 1409980.00


0.00 0.00
242 Providing protection to embedded G.I. pipes and fittings for CWS by wrapping two layers of 400 microne polythene sheet over two
coats of bitumen. Including proper overlaps on joints complete as required.

0.00 0.00
NSI 15 mm dia - 40 mm dia pipe R .Mtr 68.00 20.00 1360.00
0.00 0.00
243 NSI Providing & fixing butterfly valve tested to a pressure of 15 Kg/Sq.cm. Including rubber gasket, flanges, nuts, bolts, washers &
painting complete as required. 0.00 0.00

31 of 242
Balance work for Construction of ESIC Medical College and Hospital at Bihta ,Patna(Bihar)

Civil & Plumbing Work


Quantity Amount
S. No. Item Code Item of Work Unit Rate Remarks
DSR Non DSR DSR Non DSR
1 2 3 4 5 6 7 8 9 10
65 mm dia Nos. 2004.00 140.00 280560.00
80 mm dia Nos. 2138.00 40.00 85520.00
100 mm dia Nos. 2730.00 108.00 294840.00
0.00 0.00
244 Providing and fixing in position of approved quality G.M. float valve with copper ball float and brass rods of required length
suitable for pressure of 10 Kg/sqcm of the following sizes: 0.00 0.00
50 mm dia Nos. 2192.00 70.00 153440.00
0.00 0.00
245 NSI Providing and fixing G.I. pipe headers in various length conforming to IS:1239 heavy class including all flanged connections as per
drawing / site requirement. Supports from wall, floor and ceiling etc. Including dead end flanged connection,

0.00 0.00
50 mm dia Rmtr 319.00 222.00 70818.00
65 mm dia R .Mtr 398.00 265.00 105470.00
80 mm dia R .Mtr 477.00 9.00 4293.00
100 mm dia R .Mtr 654.00 338.00 221052.00
150 mm dia R .Mtr 961.00 408.00 392088.00
0.00 0.00
246 NSI Providing and fixing M.S. puddle flanges fabricated out of 6 mm thick M.S. plate of size 200 x 200mm plus dia of pipe of 750 mm
long pipe pieces to R.C.C. water tanks / R.C.C. walls. The entire fitting shall be hot dipped galvanised. 0.00 0.00
150mm dia Nos. 2496.00 23.00 57408.00
100mm dia Nos. 2268.00 173.00 392364.00
80mm dia Nos. 2041.00 29.00 59189.00
65mm dia Nos. 1133.00 74.00 83842.00
50mm dia Nos. 908.00 141.00 128028.00
25mm dia Nos. 567.00 10.00 5670.00
0.00 0.00
0.00 0.00
247 NSI P/F Mosquito proof coupling to over fow pipe of OHT Each 60.00 7.00 420.00
0.00 0.00
248 NSI GI rainwater spout in balcony Each 50.00 2000.00 100000.00
0.00 0.00
249 NSI P/F 40 mm dia.G.I Pipe outlet in cement mortar 1:3 (1 Cement :3 fine sand ) i/c making good the walls.
Mtr 315.46 11.00 3470.06
0.00 0.00
250 NSI (a) Providing and fixjng panels made of Glass Fibre Reinforced Concrete, as per design, logo, shade and required thickness all complete.
Sqm 4433.00 25.00 110825.00
NSI (b) Providing and fixjng allies made of Glass Fibre Reinforced Concrete, as per design, logo, shade and required thickness all complete.
Sqm 5340.00 20.00 106800.00
0.00 0.00
0.00 0.00
0.00 0.00
251 NSI Providing & fixing in position 25 mm dia lawn hydrants consisting of 25 mm dia Ball valve, GI nipple and threaded hose receiver
complete as required.
nos 1200.00 57.00 68400.00
0.00 0.00
Making connection from Existing Water Supply line including necessary excavation & making good the same including cutting,boring
&tapping the Existing line by providing and installing ferrule/Tee connections with necessary fittings as required & making good the
same.The rate for this item also includes complete services from the contractor for liasoning works such as filing necessary
applications submission of forms for approval to the municipal of the authorities depositing the fees other amounts as required
getting the premises/installations,inspected & approved & all other formalities required till water connection is obtained. All
expenses incurred in authorities,following up this regard shall be borne by the Contractor except for the payments to be made for
any security deposit etc. which will be reimbursed on production of original voucher.

job 3000.00 64.00 192000.00


Total Water Supply Work 29932175.60 9876708.06

Drainage Works
252 19.1 Providing, laying, jointing glazed stoneware pipes grade 'A' with stiff mixture of cement mortar in the proportion of 1:1 ( 1 cement;1
fine sand ) including testing of joints etc. complete:

0.00 0.00

32 of 242
Balance work for Construction of ESIC Medical College and Hospital at Bihta ,Patna(Bihar)

Civil & Plumbing Work


Quantity Amount
S. No. Item Code Item of Work Unit Rate Remarks
DSR Non DSR DSR Non DSR
1 2 3 4 5 6 7 8 9 10
19.1.3 200 mm dia Mtrs. 247.15 858.00 212054.70
19.1.5 250 mm dia Mtrs. 342.85 170.42 58428.50
0.00 0.00
253 19.2 Providing and laying cement concrete 1:5:10 (1 cement:5coarse sand:10 graded stone aggregate 40mm nominal size) all-round
S.W. pipes including bed concrete as per standard design.

0.00 0.00
19.2.3 200 mm dia Mtrs. 472.15 858.00 405104.70
19.2.5 250 mm dia Mtrs. 546.00 170.42 93049.32
0.00 0.00
254 19.4 Providing and fixing square-mouth S.W. gully trap grade 'A" complete with C.I. grating brick masonry chamber with water tight C.I.
cover with frame of 300x300 mm size ( inside ) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 Kg
as per standard design :
0.00 0.00
19.4.2.1 150x100 mm size P type with F.P.S. bricks of class designation 75.
Each 961.95 219.00 210667.05
0.00 0.00
255 19.6 Providing and laying non-pressure NP2 class (light duty) R.C.C.pipes with collars jointed with stiff mixture of cement mortar in the
proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc complete:

0.00 0.00
19.6.2 150mm dia RCC pipe Mtrs. 202.85 2400.00 486840.00
19.6.3 250mm dia RCC pipe Mtrs. 258.20 2065.00 533183.00
19.6.4 300mm dia RCC pipe Mtrs. 338.75 750.00 254062.50
19.6.6 500mm dia RCC pipe Mtrs. 584.85 70.00 40939.50
19.6.7 600mm dia RCC pipe Mtrs. 895.10 40.00 35804.00
19.6.8 700mm dia RCC pipe Mtrs. 1000.90 25.00 25022.50
19.6.9 800mm dia RCC pipe Mtrs. 1167.40 25.00 29185.00
19.6.11 1000mm dia RCC pipe Mtrs. 1740.95 25.00 43523.75
19.6.13 1200mm dia RCC pipe Mtrs. 2208.30 10.00 22083.00
0.00 0.00
256 19.7.1 Inside size 90x80 cm and 45 cm deep including C.I.cover with frame (light duty) 455x610 mm internal diameter, total weight of cover
and frame to be not less than 38 kg (weight of cover 23kg and weight of frame 15 kg):

0.00 0.00
19.7.1.1 With F.P.S. bricks class designation 75 Each 236.00
5383.70 1270553.20
19.7.3 Inside size 120x90 cm and 90 cm deep including C.I.cover with frame (Heavy duty) 560 mm internal diameter, total weight of cover
and frame to be not less than 208 kg (weight of cover 108kg and weight of frame 100 kg):

0.00 0.00
19.7.3.1 With F.P.S. bricks class designation 75 Each 15673.85 4.00 62695.40
0.00 0.00
257 19.8 Extra depth for manholes 0.00 0.00
19.8.1 Size 90x80 cm. 0.00 0.00
19.8.1.1 With F.P.S. bricks class designation 75 Mtr. 2654.00 110.00 291940.00
19.8.2 Size 120x90 cm. 0.00 0.00
19.8.2.1 With F.P.S. bricks class designation 75 Mtr. 3179.95 13.00 41339.35
0.00 0.00
258 19.9 Constructing brick masonry circular type manhole 0.91m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1
cement :4 coarse sand),in side cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a
floating coat of neat cement, foundation cocreate 1:3:6 mix (1 cement :3 coarse sand : 6 graded staone aggregate 40 mm norminal
size),and making necessary channel in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20 mm norminal
size) finished with a floating coat of neat cement all complete as per standard design:

0.00 0.00
19.9.1 0.91 m deep with S.F.R.C cover and frame (heavy duty HD-20 grade designation) 560 mm internal diameter conforming to I.S.12592,
total weight of cover and frame to be not less than 182 kg, fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand :4 graded stone
aggregate 20 mm nominal size) including centering shuttering all complete. (Excavation, foot rests and 12 mm thick cement plaster
at the external surface shall be paid for separately):

0.00 0.00

19.9.1.2 With Sewer. bricks conforming IS:4885 Each 5347.90 5.00 26739.50
0.00 0.00

33 of 242
Balance work for Construction of ESIC Medical College and Hospital at Bihta ,Patna(Bihar)

Civil & Plumbing Work


Quantity Amount
S. No. Item Code Item of Work Unit Rate Remarks
DSR Non DSR DSR Non DSR
1 2 3 4 5 6 7 8 9 10
259 19.10 Extra depth for circular type manhole 0.91 m internal dia (at bottom) beyond 0.91m to 1.67m
0.00 0.00
19.10.1 With FPS bricks class designation 75 Mtrs. 2246.90 294.00 660588.60
19.10.2 With Sewer. bricks conforming IS:4885 Mtrs. 2915.90 1.00 2915.90
0.00 0.00
260 19.10 Constructing brick masonry circular manhole 1.22m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement :4
coarse sand) inside cement plaster 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with a floating coat of
neat cement foundation concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size) and making
necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with
a floating coat of neat cement all complete as per standard design :

0.00 0.00
261 19.11 Constructing brick masonry circular manhole 1.22m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement :4
coarse sand) inside cement plaster 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with a floating coat of
neat cement foundation concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size) and making
necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with
a floating coat of neat cement all complete as per standard design :

0.00 0.00
261 19.11.1 1.68 m deep with S.F.R.C cover and frame (heavy duty HD-20 grade designation) 560 mm internal diameter conforming to I.S.12592,
total weight of cover and frame to be not less than 182 kg, fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand :4 graded stone
aggregate 20 mm nominal size) including centering shuttering all complete. (Excavation, foot rests and 12 mm thick cement plaster
at the external surface shall be paid for separately):

0.00 0.00
19.11.1.1 With F.P.S. bricks class designation 75 Each 8946.25 55.00 492043.75
19.11.1.2 With Sewer. bricks conforming IS:4885 Each 9934.70 5.00
0.00 0.00
262 19.12 Extra depth for circular type manhole 1.22 m internal dia (at bottom) with beyond 1.68m to 2.29m: 0.00 0.00
19.12.1.1 With F.P.S. bricks class designation 75 Mtrs. 2954.75 40.00 118190.00
19.12.2 With Sewer. bricks conforming IS:4885
Mtrs. 3772.05 2.00 7544.10
0.00 0.00
263 19.13 Constructing brick masonry circular type manhole 1.52m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1
cement :4 coarse sand),in side cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a
floating coat of neat cement, foundation cocreate 1:3:6 mix (1 cement :3 coarse sand : 6 graded staone aggregate 40 mm norminal
size),and making necessary channel in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20 mm norminal
size) finished with a floating coat of neat cement all complete as per standard design:

0.00 0.00
19.13.1 2.30 m deep with S.F.R.C cover and frame (heavy duty HD-20 grade designation) 560 mm internal diameter conforming to I.S.12592,
total weight of cover and frame to be not less than 182 kg, fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand :4 graded stone
aggregate 20 mm nominal size) including centering shuttering all complete. (Excavation, foot rests and 12 mm thick cement plaster
at the external surface shall be paid for separately):

0.00 0.00
19.13.1.1 With F.P.S. bricks class designation 75 Each 18281.60 32.00 585011.20
19.13.1.2 With Sewer. bricks conforming IS:4885 Each 21089.40 3.00 63268.20
0.00 0.00
264 19.14 Extra depth for circular type manhole 1.52 m internal dia (at bottom) with beyond 1.68m to 2.30m: 0.00 0.00
19.14.1 With F.P.S. bricks class designation 75 Mtrs. 6956.05 25.00 173901.25
With Sewer. bricks conforming IS:4885
19.14.1 Mtrs. 9069.45 2.00 18138.90
0.00 0.00

34 of 242
Balance work for Construction of ESIC Medical College and Hospital at Bihta ,Patna(Bihar)

Civil & Plumbing Work


Quantity Amount
S. No. Item Code Item of Work Unit Rate Remarks
DSR Non DSR DSR Non DSR
1 2 3 4 5 6 7 8 9 10
265 19.21 Making connection of drain or sewer line with existing manhole , including breaking into & making good the walls ,floors with
cement concrete 1:2:4 mix ( 1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size ) cement plastered on both
sides with cement mortar 1:3 ( 1 cement :3 coarse sand ) finished with floating coat of neat cement & making necessary channels for
the drain etc. complete.

0.00 0.00
19.21.3 For Pipes 350 to 450 mm diameter Each 302.95 2.00 605.90
0.00 0.00
266 NSI Providing, laying, jointing and testing in position the following glazed stone ware pipes grade `A' with stiff mixture of
cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) laid below ground level in trenches upto required depth
including excavation in all kind of soil (hard rock) dewatering, refilling, watering, ramming & removing the surplus excavated
material and making good the same complete as required.

0.00 0.00
300 mm dia Mtr. 1800.00 5.00 0.00 9000.00
350 mm dia Mtr. 2000.00 30.00 0.00 60000.00
400 mm dia Mtr. 2200.00 356.00 0.00 783200.00
500 mm dia Mtr. 2450.00 14.00 0.00 34300.00
600 mm dia Mtr. 2650.00 20.00 0.00 53000.00
650 mm dia Mtr. 2900.00 20.00 0.00 58000.00
0.00 0.00
267 NSI Constructing Grease trap size 1200x1200mm internal size of 1000mm depth in brick work of class 75 with cement mortar (1:5)
Inside 12mm thick with cement mortar 1:3 with floating coat of neat cement and rough plaster on outside. including 4mm thick SS-
304 plate with perforations & lifting Rod (2 Nos.) RCC top slab with 500mm dia medium duty manhole covers with frame (weight of
cover 58 kg. & weight of frame 58 kg.), 150mm thick foundation concrete (1 :4 : 8), necessary excavation, dewatering, refilling,
watering, ramming and removing the surplus excavated material and making good the same complete as required.

Sets 20000.00 10.00 0.00 200000.00


0.00 0.00
268 NSI Providing and laying non-pressure NP2/NP3 class RCC pipes with S & S jointed with stiff mixture of cement mortar in the proportion
of 1:2 (1 cement : 2 fine sand) including testing of joints etc complete. 0.00 0.00
200mm dia RCC pipe Mtrs. 390.00 70.00 0.00 27300.00
400mm dia RCC pipe Mtrs. 780.00 375.00 0.00 292500.00
1400mm dia RCC pipe Mtrs. 6240.00 5.00 0.00 31200.00
1500mm dia RCC pipe Mtrs. 7200.00 5.00 0.00 36000.00
1600mm dia RCC pipe Mtrs. 9000.00 8.00 0.00 72000.00
0.00 0.00
269 NSI Providing and laying 150 mm thick cement concrete 1:4:8 (1 cement:4 fine sand:8 graded stone aggregate 40mm nominal size)
alround pipes including 100 mm thick bed concrete as per standard design. 0.00 0.00
200mm dia RCC pipe Mtrs. 550.00 70.00 0.00 38500.00
400mm dia RCC pipe Mtrs. 850.00 375.00 0.00 318750.00
1400mm dia RCC pipe Mtrs. 2000.00 5.00 0.00 10000.00
1500mm dia RCC pipe Mtrs. 2150.00 5.00 0.00 10750.00
1600mm dia RCC pipe Mtrs. 2350.00 5.00 0.00 11750.00
0.00 0.00
270 NSI Constructing brick masonry road/ surface ground gully chamber 45x45x45 cm with brick of class designation75 in cement mortar 1:5
(1cement :5 fine sand) including 500x450mm precast R.C.C horizontal grating with frame complete as per standard design with F.P.S
Bricks.
Each 1500.00 445.00 0.00 667500.00
271 NSI Extra for Depth for brick masonary road/ Surface gully chamber size 45x45x45cm Mtr. 1250.00 470.00 587500.00
0.00 0.00
272 NSI Constructing Brick masonary Square/circular rain water harvesting tank of size exact as per site / service drawing, including
providing of filteration bed media in harvesting tank in different layers - 0.5mm thick sand of 1.5 to 2.0m size (4 Cum), 0.5mm thick
gravel of 5-10mm size (4 Cum), 0.5mm thick boulders of 5-15mm size (4 Cum) in storm water collection tank including 160mm dia
UPVC perforated pipe upto required depth below subsoil water table complete as per standard design.

0.00 0.00
Boring Size-300 mm Dia,Chamber size-(2mx2mx2m) Nos. 28.00
250000.00 0.00 7000000.00
Total Drainage Works as per DSR 6265422.77 10301250.00

ALUMINIUM WORK 0.00

35 of 242
Balance work for Construction of ESIC Medical College and Hospital at Bihta ,Patna(Bihar)

Civil & Plumbing Work


Quantity Amount
S. No. Item Code Item of Work Unit Rate Remarks
DSR Non DSR DSR Non DSR
1 2 3 4 5 6 7 8 9 10
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up
standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733
and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including
necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc.
uminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required
including cleat angle, Aluminium snap
273 21.1 0.00 0.00
beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings
and the directions of Engineer-in-charge. (Glazing and panelling to be paid for separately) :

Powder coated aluminium (minimum thickness of powder coating 50 micron)


21.1.1.2 kg 306.30 179609.75 55014466.43

For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision
for fixing of fittings wherever required including the cost of PVC / neoprene gasket required (Fittings shall be
21.1.2 paid for separately). 0.00 0.00 0.00

Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic
21.1.2.1 coating of grade AC 15) kg 310.45 40.00 12418.00

Powder coated aluminium (minimum thickness of powder coating 50 micron)


21.1.2.2 kg 326.60 101558.51 33169009.37

Providing and fixing 12mm thick Pre-laminated particle board flat pressed three layer or graded wood particle
board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminium doors, windows shutters and
partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and
274 21.2 directions of engineer-in-charge. 0.00 0.00 0.00

Pre-laminated particle board with decorative lamination on both sides.


21.2.2 sqm 812.60 4192.50 3406825.50

Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC/
neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge .
(Cost of aluminium snap beading shall be paid in basic item) :
275 21.3 0.00 0.00 0.00

21.3.1 With float glass panes of 4.0 mm thickness sqm 554.95 2817.00 1563294.15
21.3.2 With float glass panes of 5.50 mm thickness sqm 673.55 5695.00 3835867.25

Providing and fixing double action hydraulic floor spring of approved brand and manufacture IS : 6315 marked,
for doors including cost of cutting floors as required, embedding in floors and cover plates with brass pivot and
single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge.
276 21.4 0.00 0.00 0.00

21.4.1 With stainless steel cover plate each 1733.50 2431.00 4214138.50

Providing and fixing aluminium tubular handle bar 32 mm outer dia, 3.0 mm thick & 2100 mm long with SS
277 21.12 screws etc .complete as per direction of Engineer-in-Charge. 0.00 0.00 0.00

Powder coated minimum thickness 50 micron aluminium tubular handle bar.


21.12.2 Each 458.45 60.00 27507.00

Polyester powder coated minimum thickness 50 micron aluminium tubular handle bar
21.12.3 Each 467.95 60.00 28077.00

36 of 242
Balance work for Construction of ESIC Medical College and Hospital at Bihta ,Patna(Bihar)

Civil & Plumbing Work


Quantity Amount
S. No. Item Code Item of Work Unit Rate Remarks
DSR Non DSR DSR Non DSR
1 2 3 4 5 6 7 8 9 10
Providing and fixing 100mm brass locks (best make of approved quality) for aluminium doors including
278 21.13 necessary cutting and making good etc. complete. Each 208.35 0 0

Providing and fixing aluminium round shape handle of outer dia.100 mm with SS screws etc. complete as per
279 21.16 direction of E-in-CHARGE 0.00 0.00 0.00

21.16.3 Polyester powder coated minimum thickness 50 micron aluminium . Each 52.30 20.00 1046.00
TOTAL ALUMINIUM WORK 0.00 101272649.19 0.00
0.00
WATER PROOFING 0.00
Providing and laying integral cement based treatment for water proofing on horizontal surface at all depth below
ground level for under ground structures as directed by Engineer-in-Charge and consisting of : i) Ist layer of
22mm to 25mm thick approved and specified rough stone slab over a 25mm thick base of cement mortar 1:3 (1
cement : 3 coarse sand) mixed with water proofing compound conforming to IS:2645 in the recommended
proportion over the levelling course (levelling course to be paid separately). Joints sealed and grouted with
cement slurry mixed with water proofing compound . ii) 2nd layer of 25mm thick cement mortar 1:3 (1 cement :
280 22.1 3 coarse sand) mixed with water proofing compound in recommended proportions. iii) Finishing top with stone 0.00 0.00
aggregate of 10mm to 12mm nominal size spreading @ 8 cudm/sqm thoroughly embedded in the 2nd layer.

22.1.1 Using rough Kota stone. sqm 540.30 852.30 460497.69

Providing and laying integral cement based treatment for water proofing on the vertical surface by fixing
specified stone slab 22 mm to 25mm thick with cement slurry mixed with water proofing compound conforming
to IS:2645 in recommended proportions with a gap of 20mm (minimum) between stone slabs and the receiving
surfaces and filling the gaps with neat cement slurry mixed with water proofing compound and finishing the
281 22.2 exterior of stone slab with cement mortar 1:3 (1 cement : 3 coarse sand) 20mm thick with neat cement punning 0.00 0.00 0.00
mixed with water proofing compound in recommended proportion complete at all levels and as directed by
Engineer-in-charge :

22.2.1 Using rough Kota stone sqm 647.85 605.00 391949.25

Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C.,
kitchen and the like consisting of : i) Ist course of applying cement slurry @ 4.4 Kg/sum mixed with water
proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of
vertical and horizontal surface. ii) IInd course of 20mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed
with water proofing compound in recommended proportion including rounding off junction of vertical and
horizontal surface. iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 Kg. per sum of area.
iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and
282 22.3 pasted to each other with bitumen @ 1.7 Kg/sum.) sqm 272.50 3639.00 991627.50

Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement
slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @
0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air
cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement
compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48
283 22.5 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes sqm 143.85 5995.00 862380.75
and masonry with polymer mixed slurry.

37 of 242
Balance work for Construction of ESIC Medical College and Hospital at Bihta ,Patna(Bihar)

Civil & Plumbing Work


Quantity Amount
S. No. Item Code Item of Work Unit Rate Remarks
DSR Non DSR DSR Non DSR
1 2 3 4 5 6 7 8 9 10
Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water
proofing cement compound consisting of applying : a) after surface preparation, first layer of slurry of cement @
0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. b) laying second layer of Fibre
glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. c)
third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing
cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4
hours followed by water curing for 48 hours. The entire treatment will be taken upto 30cm on parapet wall and
284 22.6 tucked into groove in parapet all around. d) fourth and final layer of brick tiling with cement mortar (which will be sqm 237.50 5859.00 1391512.50
paid for separately For the purpose of measurement the entire treated surface will be measured.

Providing and laying integral cement based water proofing treatment including preparation of surface as
required for treatment of roofs, balconies, terraces etc consisting of following operations: a) Applying a slurry
coat of neat cement using 2.75 kg/sqm. of cement admixed with water proofing compound conforming to IS.
2645 and approved by Eng-in-charge over the RCC slab including adjoining walls upto 300mm height including
cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to
115mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound
conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix
1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and p g p g
approved by Eng-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height
285 22.7 including rounding of junctions of walls and slabs c) After two days of proper curing applying a second coat of 0.00 0.00
cement slurry using 2.75kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and
approved by Eng-in-charge.

d)Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed
with water proofing compound conforming to IS : 2645 and approved by Eng-in-charge including laying glass
fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement
slurry and making pattern of 300x300 mm square 3mm deep. e) The whole terrace so finished shall be flooded
with water for a minimum period of two weeks for curing and for final test. All above operations to be done in
order and as directed and specified by the Eng-in-Charge :
0.00 0.00

With average thickness of 120mm and minimum thickness at khurra as 65 mm.


22.7.1 sqm 541.50 500.00 270750.00

286 22.14 Grading roof for water proofing treatment with 0.00 0.00
22.14.2 Cement mortar 1:3 (1 cement : 3 coarse sand) cum 5045.35 2.00 10090.70

TOTAL WATER PROOFING 0.00 4378808.39 0.00

Horticulture Work 0.00


Trenching in ordinary soil upto a depth of 60cm including removal and stacking of serviceable materials and
then disposing of by spreading and neatly levelling with in a lead of 50m and making up the trenched area to
proper levels by filling with earth or earth mixed with sludge or/and manure before and after flooding trench with
287 23.1 water (excluding cost of imported earth, sludge or manure). cum 16.95 3000.00 50850.00

Supplying and stacking of good earth at site including royalty and carriage upto 1 km (earth measured in stacks
288 23.2 will be reduced by 20% for payment). cum 144.05 500.00 72025.00

38 of 242
Balance work for Construction of ESIC Medical College and Hospital at Bihta ,Patna(Bihar)

Civil & Plumbing Work


Quantity Amount
S. No. Item Code Item of Work Unit Rate Remarks
DSR Non DSR DSR Non DSR
1 2 3 4 5 6 7 8 9 10
Supplying and stacking sludge at site including royalty and carriage upto 1 km (sludge measured in stacks will
289 23.3 be reduced by 8% for payment). cum 136.85 500.00 68425.00

Supplying and stacking at site dump manure from approved source including carriage upto 1 km (manure
measured in stacks will be reduced by 8% for payment):
290 23.4 0.00 0.00 0.00

23.4.2 Screened through sieve of IS designation 16mm cum 90.75 500.00 45375.00

291 23.5 Rough dressing the trenched ground including breaking clods. 100 sqm 33.05 120.00 3966.00

Uprooting weeds from the trenched area after 10 to 15 days of its flooding with water including disposal of 100
292 23.6 uprooted vegetation. 106.85 120.00 12822.00
sqm

Fine dressing the ground 100


293 23.7 80.20 120.00 9624.00
sqm

Spreading of sludge, dump manure or/and good earth in required thickness (Cost of sludge, dump manure or/
294 23.8 and good earth to be paid eparately). cum 11.60 3000.00 34800.00

Grassing with ‘Doob’ grass including watering and maintenance of the lawn for 30 days or more till the grass
forms a thick lawn free from weeds and fit for mowing including supplying good earth if needed (the good earth
295 23.10 shall be paid for separately). 0.00 0.00 0.00

23.10.2 In rows 7.5 cm apart in either direction. 100 sqm 251.25 120.00 30150.00

Uprooting rank vegetation and weeds by digging the area to a depth of 60cm removing all weeds and other
growth with roots by forking repeatedly, breaking clods, rough dressing, flooding with water, uprooting fresh
growths after 10 to 15 days and then fine dressing for planting new grass, including disposal of all rubbish with 100
296 23.12 all leads and lifts. 1318.20 5.00 6591.00
sqm

Preparation of beds for hedging and shrubbery by excavating 60cm deep and trenching the excavated base to
a further depth of 30cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in
the ratio of 8:1 (8 parts of stacked volume of earth after reduction by 20% : one part of stacked volume of
sludge or manure after reduction by 8%), flooding with water, filling with earth if necessary, watering and finally
fine dressing, levelling etc. including stacking and disposal of materials declared unserviceable and surplus
297 23.13 earth by spreading and levelling as directed, within a lead of 50m lift upto 1.5 m complete (cost of sludge, cum 47.90 2842.00 136131.80
manure or extra earth to be paid for separately).

Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in
the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume
of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if
any with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) :
298 23.14 0.00 0.00 0.00

23.14.1 Holes 1.2 m dia and 1.2 m deep. each 146.65 1000.00 146650.00

23.14.2 Holes 60 cm dia, and 60 cm deep. each 19.25 225.00 4331.25

39 of 242
Balance work for Construction of ESIC Medical College and Hospital at Bihta ,Patna(Bihar)

Civil & Plumbing Work


Quantity Amount
S. No. Item Code Item of Work Unit Rate Remarks
DSR Non DSR DSR Non DSR
1 2 3 4 5 6 7 8 9 10
Filling mixture of earth and sludge or manure in the desired proportion in trenches, flooding with water and
levelling (cost of supplying earth and sludge or manure and mixing excluded).
299 23.20 cum 3.95 4000.00 15800.00

Flooding the ground with water including making kiaries and dismantling the same. 100
300 23.24 68.40 108.00 7387.20
sqm

providing and fixing regal garden bench of length 1.2 m and depth .6 m complete
301 NSI each 10000.00 50.00 0.00 500000.00

Providing and fixing aluminium dustbin of height 600mm and dia 300mm in all complete.
302 NSI each 4700.00 45.00 0.00 211500.00

0.00
303 NSI Supplying at site ,weed free selection no.1 grass in carpet form sqm 15.00 12000.00 0.00 180000.00
Roadside and boundary wall side plantation 0.00 0.00 0.00 0.00

304 NSI Grevillea Robusta 8ft ht each 80.00 1000.00 0.00 80000.00

305 NSI Alestonia Scholaris 8 ft ht each 80.00 25.00 0.00 2000.00

306 NSI Schleichera (kusum)5 ft ht each 200.00 25.00 0.00 5000.00

307 NSI Bottle Palm 8 ft ht each 1200.00 100.00 0.00 120000.00

308 NSI Plumerea alba 6ft ht each 300.00 25.00 0.00 7500.00

309 NSI Cassia fistula 4-5 ft ht each 60.00 25.00 0.00 1500.00

310 NSI Azadirecta indica 5-6 ftht each 60.00 50.00 0.00 3000.00

311 NSI Bauhinia blakena 6 ft ht each 60.00 25.00 0.00 1500.00

312 NSI Delonix regia 8 ft ht each 80.00 40.00 0.00 3200.00

313 NSI Peltophorum terocarpum 6 ft ht each 80.00 25.00 0.00 2000.00

314 NSI Acacia auriculiformis 6 ft ht each 60.00 25.00 0.00 1500.00

315 NSI Mimosops elengi 6 ft ht each 200.00 25.00 0.00 5000.00

316 NSI Ficus retusa 8ft ht each 200.00 25.00 0.00 5000.00

317 NSI Lagerstromia flosrajani 8ft ht each 60.00 25.00 0.00 1500.00

318 NSI Bombax ceiba8ft ht each 200.00 25.00 0.00 5000.00

319 NSI Chorosea spesiosa 8ft ht each 500.00 15.00 0.00 7500.00

320 NSI Kanak champa 8ft ht each 100.00 15.00 0.00 1500.00

321 NSI Baugenvilla 1 ft ht (Kolkata varieties) each 20.00 500.00 0.00 10000.00

Central Park - plantation 0.00 0.00 0.00 0.00


322 NSI Murraya exotica (hedge ) 1 ft ht each 10.00 600.00 0.00 6000.00

40 of 242
Balance work for Construction of ESIC Medical College and Hospital at Bihta ,Patna(Bihar)

Civil & Plumbing Work


Quantity Amount
S. No. Item Code Item of Work Unit Rate Remarks
DSR Non DSR DSR Non DSR
1 2 3 4 5 6 7 8 9 10
323 NSI Durenta golden ( edge) 1 ft ht each 8.00 1000.00 0.00 8000.00
324 NSI Cassia biflora 4ft ht 8”potted each 80.00 15.00 0.00 1200.00
325 NSI Lagerstromia indica rosea 4ft ht 8”potted each 80.00 15.00 0.00 1200.00
326 NSI Bauhinia accuminata 2ft ht 8”potted each 200.00 15.00 0.00 3000.00
327 NSI Ticoma gaurichauri 2ft ht 8”potted each 80.00 15.00 0.00 1200.00
328 NSI Nyctanthes arbor-tristis (harsingar) each 100.00 5.00 0.00 500.00
329 NSI Plumerea champa 6 ft ht each 800.00 15.00 0.00 12000.00
Parks plantation 0.00 0.00 0.00 0.00
330 NSI Narium oleander varigated 8” potted each 50.00 100.00 0.00 5000.00
331 NSI Acalypha 8” potted each 25.00 100.00 0.00 2500.00
332 NSI Plumbego 8” potted each 80.00 50.00 0.00 4000.00
333 NSI Hybrid Euphorbea milli 8” potted each 100.00 100.00 0.00 10000.00
334 NSI Exora 8”potted each 150.00 100.00 0.00 15000.00
335 NSI Ficus variegated 4-5 ft ht each 800.00 5.00 0.00 4000.00
336 NSI Ficus westland 4-5 ft ht each 800.00 5.00 0.00 4000.00
337 NSI Ticoma capansis 8” potted each 80.00 50.00 0.00 4000.00
338 NSI Ticoma gaurichauri 8” potted each 80.00 50.00 0.00 4000.00
339 NSI Ficus viviana 4-5 ft ht each 400.00 10.00 0.00 4000.00
340 NSI Mussaenda erythrophylla 8” potted each 150.00 50.00 0.00 7500.00
341 NSI Tabernae Montana coronaria variegated 8” potted each 80.00 50.00 0.00 4000.00
342 NSI Thryallis glauca 8” potted each 80.00 50.00 0.00 4000.00
343 NSI Murraya exotica 8” potted each 60.00 50.00 0.00 3000.00
344 NSI Asperagus mairry 8” potted each 100.00 100.00 0.00 10000.00
345 NSI Alenthera each 5.00 2000.00 0.00 10000.00
346 NSI Erasin each 5.00 2000.00 0.00 10000.00
347 NSI Durenta golden 1 ft ht (edge) each 8.00 1500.00 0.00 12000.00
348 NSI Hamelia patans 8” potted (hedge) each 60.00 750.00 0.00 45000.00
349 NSI Plumeria rubra 6 ft ht each 2000.00 20.00 0.00 40000.00
350 NSI Foxtail palm 8 ft ht each 2000.00 15.00 0.00 30000.00
351 NSI Cycus revolute 1 ft ht black stem each 3000.00 15.00 0.00 45000.00
352 NSI Magnolia champa 5 ft ht each 3000.00 8.00 0.00 24000.00
supplying and installation of Geyser jet and string fall fountain with LED based lights
353 NSI each 164536.00 2.00 0.00 329072.00

supplying and installation of vertical jet and water sheet fountain with LED based lights
354 NSI each 279496.00 2.00 0.00 558992.00

TOTAL HORTICULTURE AND LANDSCAPE WORKS 0.00 644928.25 2376364.00

41 of 242
Balance work for Construction of ESIC Medical College and Hospital at Bihta ,Patna(Bihar)

BALANCE BOQ of Furniture, Roller Blinds, Signages, Back lit Glass, Modular Lockers & Toilets, Acoustic

Sl. No. Description DSR NON DSR Total

1 2 3 4 5

1 FURNITURE 14764810.68 14764810.68

2 ROLLER BLINDS 9300096.00 9300096.00

3 SIGNAGES (EXTERNAL & INTERNAL) 0.00 0.00

4 BACK LIT GLASS 0.00 0.00

5 MODULAR LOCKERS & MODULAR TOILETS 44015070.48 44015070.48

ACOUSTICS & PA/ LIGHT SYSTEMS (FOR LECTURE ROOMS/


6 94661875.00 94661875.00
AUDITORIUM)

SUB TOTAL = ( A ) = 162741852.16


Balance work for Construction of ESIC Medical College and Hospital at Bihta ,Patna(Bihar)

Interior Works

BOQ of Roller Blind, Back lit Glass, Modular Lockers & Toilets, Acoustic

Quantity Amount
S.No. Description Unit Rate Remarks
DSR Non DSR DSR Non DSR
1 2 3 4 5 6 7 8 9
1 Part 1 FURNITURE

Providing & fixing/installation of fixed/moveable modular furniture items of


Godrej/ equivalent make as approved by the client. The furniture shall be of
standard make and design and shall comply all relevant BIS codes and shall
1 be of/ match Godrej or equilent make products, as mentioned below. The
work is inclusive of all the fixtures, fittings, accessories, assembly units and
parts required for effective functional usage of the furniture & to the
satisfaction of Engineers-in charge.

Bed EUDORA KING BED NEW BEECH Each


32435.00 32.00 1037920.00

Sofa 3 Seater D-ALPINA as per Sr.no. A7 Each


17655.00 65.00 1147575.00
Sofa 1 Seater D-ALPINA Each
10711.00 2.00 21422.00
sofa 2 seater D-ALPINA: as per Sr.no. A8 Each
13589.00 74.00 1005586.00
Center Table ALICE Each
8531.00 11.00 93841.00
Side Table C531EX Centre piece-530 Each
2575.00 154.00 396550.00
Non-Celeicel Staff Table VERSATILA V2 Each
11000.58 19.00 209011.02
Center Table ALICE Each
8531.00 85.00 725135.00
Lecture Table Chair PCH-9P02 A Each
8087.03 750.00 6065272.50
Chair PCH-9103RV Each
7859.93 12.00 94319.16
Computer Table COMPANION - C3 D Each
6941.00 5.00 34705.00
BOQ of Roller Blind, Back lit Glass, Modular Lockers & Toilets, Acoustic

Quantity Amount
S.No. Description Unit Rate Remarks
DSR Non DSR DSR Non DSR
Easy Chair WALES RECLINER SYNTHETIC LEATHER: as per Sr.no. A5 Each
24900.00 56.00 1394400.00
T.V Unit ODEUM X2 WALL UNIT (2 GLASS DOOR UNIT) Each
9226.00 37.00 341362.00
Cabinet STORWEL PLAIN Each
12487.00 176.00 2197712.00

Total Furniture 14764810.68

SH 1 ROLLER BLINDS

Providing and fixing Roller Blinds of standard make using fabric


woven in a nature weave pattern. The fabric shall be composed
of75% PVC 25% POLISTER. It shall be 0.55mm thk and weight
380 gms /sq. mtr, The fabric shall have Screen of the fabric to
give stiffness and reduce intensity of sunlight. Fabric shall be
constructed from spun - bounded fibre, precision manufactured
to form a hexagonally shaped, dual pleat , celluar construction.
1 Sqm 968.40 9603.57 9300096.00
All cords & cords holes shall be fully concealed inside the fabric
structure. pleats operated independently of each other providing
superor pleat retention & structure strength. the work shall
include complete installation including providing tilt rod, runners,
spacers, transverse cord, tilter chain, cord weight, bottom weight
& chain etc., as detail specifications and to the satisfaction of the
Engineer-in-Charge.

Toal for Roller Blinds 9300096.00


BOQ of Roller Blind, Back lit Glass, Modular Lockers & Toilets, Acoustic

Quantity Amount
S.No. Description Unit Rate Remarks
DSR Non DSR DSR Non DSR
SIGNAGES (EXTERNAL & INTERNAL)

Providing and installation of fixed/ moveable signages at various


locations made up of 1.2mm thick stainless steel sheet duly
etching letter (single side) complete as per the detail architectural Sqm 0.00 0.00 0.00
drawings and specifications as to the satisfaction of the
Engineer-in-Charge.

TOTAL SIGNAGES (EXTERNAL & INTERNAL) 0.00


SH 3 BACK LIT GLASS

Providing & fixing of 21.52mm thick toughened laminated glass


with one layer of milky white PBB amd 3 layers of clear PBB. The
glass façade fixed with the spider fittings (Dorma or equivalent)
along with CSB M12 Boards. The glasses to be supported on
1 steel structure. the parameter of facade to be fixed with anodized Sqm 0.00 0.00 0.00
aluminum channels of required size and filled with silicon. the
work shall be executed as per the detail drawings complete with
all necessary hardware fitting, fixtures, scaffoldings etc. and to
the satisfaction of the Engineer-in-Charge.

Total for Back Lit Glass 0.00


SH 4 MODULAR LOCKERS
BOQ of Roller Blind, Back lit Glass, Modular Lockers & Toilets, Acoustic

Quantity Amount
S.No. Description Unit Rate Remarks
DSR Non DSR DSR Non DSR

Providing and installation of modular locker units (Width 300mm


x Depth 450mm x Height 1800 mm) of standard make (Merino/
equivalant) complete door made of 12mm thick solid compact
laminate, back & side dividers shall be 3mm thick solid compact
laminate, top & bottom base 9mm thick solid compact laminate,
constructed on aluminum interlocking support frame work with
1 No. 0.00 0.00 0.00
consealed hinges (grade 304), 5 pin security lock with numbering
plate, color shade and tier as per the detail drawing, with all
fixtures, fittings, shelves, base work for installation etc. The
laminate shall be high pressure laminates conforming to EN 438:
1991 Standards and shall be made as to the satisfaction of
Engineer-in-Charge and to comply the detail specifications.

SH 5 MODULAR TOILETS

Supply and installation of standard modular toilet units of repute


make with standard cubical dimensions 900 x 1550mm, standard
door size 650mm with standard floor clearance 150mm. all doors
shall be single color 12mm thick compact laminate with
shamphard edge and each will be supported by nylon hinges
1 affixed to vertical aluminum pole. Pilasters shall be of same color No 38009.56 1158.00 44015070.48
as door, 12mm thick compact laminated. The design and
accessories shall be of nylon and shall meet the standards. The
design and fixing shall match Merino (Doric Series)/ equivalent
as per Engineer-in-Charge's approval and shall be as per the
detail specifications.

Total for Modular Lockers & Toilets 44015070.48


BOQ of Roller Blind, Back lit Glass, Modular Lockers & Toilets, Acoustic

Quantity Amount
S.No. Description Unit Rate Remarks
DSR Non DSR DSR Non DSR
PART II - ACOUSTICAL TREATMENT, PROJECTION
SH 6
SYSTEM, AUDIO-VISUAL SYSTEM, LIGHTING WORKS
SH 1 ACOUSTICAL TREATMENT CEILING:
1
P/f of acoustical ceiling consisting of Square edge Acoustical
panels offering a crisp, granulated surface Glass fiber acoustic
ceiling tile ANUTONE, SUBTEX or equivalent make in size
600x600x15mm having noise reduction co-efficient of 0.9,
Density of 100 kg / m3, and Humidity resistance of 95% to be laid sqm 1875.00 1710.00 3206250.00
on exposed grid system with white wrap comprising main runner
3.00 mm x 38mm web height cross tee 1.2 mtrs x 38 mm web
height and 0.6 mtrs x 38 mm web height. The wall angle shall be
3.0 mtrs.

2
Providing & fixing at all height false ceiling of 20 mm thick Mat
Black ANUTONE or equivalent make panels of size1200 x 600
mm laid over MS Suspension Grid consisting of 2 nos 40 X 40X sqm 4450.00 450.00 2002500.00
5mm MS Angles welded back to back @1200mm c/c & M.S.
Tees @ 600mm c/c .
SH 2 ACOUSTICAL TREATMENT WALL PANELING:
1
Providing and Fixing Anutone Sound Soft Respond ACT
(Guilford) -25mm. For wall panel, this fabric is treated with fire
retardant and dirt repellant coating of size 1200x600x25mm to be
installed on 9mm th. Commercial ply, Anutone Sound profile,
sqm 8375.00 1580.00 13232500.00
Impaling clip/ sound stick S7. The treatment will give an NRC of
0.8 Anutone Sound Soft Respond ACT 25mm for wall meet the
stringent fire test required having class-A rating for flame
ignitibility test as per ASTM E-84 with Anutone Sound Profile .
BOQ of Roller Blind, Back lit Glass, Modular Lockers & Toilets, Acoustic

Quantity Amount
S.No. Description Unit Rate Remarks
DSR Non DSR DSR Non DSR
2
Providing and Fixing Anutone Ekcelsior SoundSlats 16mm Panel
L32 or equivalent make for Wall Ideacustic Tile is to be fixed
on ASP C-System Anutone SoundStrut pre-engineered cross
channel section & perimeter channel of G I section Knurled Web
of size 18 mm and two equal flanges of 15 mm each with 0.45
mm thickness of prime quality cold rolled steel as per IS 513 hot
dipped galvanized 120 gsm as per BS 2989 and zinc coating as
per IS 277 on CC-18 main channel and perimeter channel on sqm 18125.00 550.00 9968750.00
floor and ceiling channel is to be fixed with plastic sleeves and
wooden screws to form the proper framework with Fixing Cleat
for holding Tiles in Tongue &Groove system. The SoundSynth
AW 10x50 of density 1000 GSM should be used as inserted in
the cavity of channels. The SoundSlats 16mm Panel L32 for Wall
Ideacustic Tile can be installed with fixing cleat in line & level
of the framework with Cleat system as shown in Drawing.

3 Providing & fixing 150mm high polished wooden skirting. Rmtr 495.00 325.00 160875.00
SH 3 HALL FURNISHING
a Providing and fixing Push back type Auditorium chairs with PU
seat and back and upholstered with inherent fire retardant fabric
Each 0.00 0.00 0.00
Make: Rana Chairs or equivalent make
Model : PBPR/PBEX
i Installation of Chairs at Site as per direction of Engineer-in-
Each 0.00 0.00 0.00
charge.
ii Providing and fixing Cut pile tufted Carpet flooring made of 100%
BCF heatset nylon, Dyed by Chromojet injection dye with a tufted
weight of +/- 1165 G/SQM (34.35 Oz/Sqyd) , Gauge : 1/10" with
sqm 1925.00 969.00 1865325.00
14 stitches per inch and a total weight of 2500 G/SQM with
primary backing in woven polypropelene and secondary
synthetic action back.
SH 4 SOUND REDUCING DOORS
BOQ of Roller Blind, Back lit Glass, Modular Lockers & Toilets, Acoustic

Quantity Amount
S.No. Description Unit Rate Remarks
DSR Non DSR DSR Non DSR
i Fabricating and fixing on site 75mm thk accoustic sound
reducing doors made with 2nd class Teak Wood framework, infill
in 48 kg/ cum density resin bonded glasswool with 12mm
sqm 18500.00 37.00 684500.00
commercial ply and 4mm thick veneer on both sides . Cost
includes Sal wood Chowkhat (section size : 5" x 3") and
melamine polish over veneer ply.
ii Providing and fixing Panic Bars for double leaf doors.
Each 38000.00 15.00 570000.00
Make: Dorma or Briton or equivalent make
iii Providing and fixing heavy duty Stainless steel hinges with ball
bearings. Make: Door Each 950.00 40.00 38000.00
King or equivalent.
iv
Providing and fixing door closers. Make:
Each 6500.00 23.00 149500.00
Dorma or Briton or equivalent make
v Providing and fixing 600mm long Stainless steel door handles in
MAT finish. Make: Door Each 4500.00 23.00 103500.00
King or equivalent or equivalent make
SH 5 Supplying, Installation & Commissioning of VIDEO
PROJECTION SYSTEM consisting of below mentioned
equipments & components etc. complete to the satisfaction
of Engineer-in-charge.
i Projection System with DLP Technology, with native resolution of
1920 x 1080 pixels , 12000 ANSI lumens , 16:9 aspect ratio Each 4968000.00 3.00 14904000.00
HD .3 chip Wide projector
Approved Make : Panasonic or equivalent make
ii Long Throw Projection Lens, complete as per specification and
Each 475000.00 3.00 1425000.00
as required.
iii 30' x 22' motorized screen Each 1170000.00 3.00 3510000.00
Approved make : Draper/ Dalite
iv Prof DVD Player Each 18000.00 3.00 54000.00
Approved Make: PHILIPS or equivalent make
BOQ of Roller Blind, Back lit Glass, Modular Lockers & Toilets, Acoustic

Quantity Amount
S.No. Description Unit Rate Remarks
DSR Non DSR DSR Non DSR
v Multisystem Format Converter to convert NTSC,, PAL ,SECAM
Each 80000.00 3.00 240000.00
to any format as per requirement.
Approved Make JVC / PANASONIC /Cyer P
vi RGB Video Data Switcher, 7 inputs , 1 output with matrix &
Each 295000.00 3.00 885000.00
scaler
Approved Make : Extron / falsom / Anologway
vii Touch Control System complete with 15" colour panel , Button
panel , Processor , IR Probes with all required interface to control Each 1080000.00 3.00 3240000.00
audio-video system.
Makes : Crestron/ AMX or equivalent make
viii
Multipoint Video Conferencing with compatability with ISDN Lines Each 1155000.00 3.00 3465000.00
Makes : Polycom/ Sony / Tanbers
ix CCD Camera with integrated tilt , Pan & zoom with cordless
Each 190000.00 23.00 4370000.00
remote control.
Makes : Canon/ Sony/ Palco
x High Definition LCD Plasma Screen, 50" Each 247500.00 3.00 742500.00
Makes: Hitachi, LG, Samsung
xi Wiring for system in PVC conduits job 325000.00 3.00 975000.00
xii Installation, testing and commissioning of Video Projection
job 250000.00 3.00 750000.00
system.
SH 6 Supplying, Installation & Commissioning of SOUND
REINFORCEMENT SYSTEM consisting of below mentioned
equipments & components etc. complete to the satisfaction
of Engineer-in-charge.
(a) SPEAKER
i
12"-inch two-way Line-array loudspeaker in a Trapezoidal
Enclosure; 800W @ 8 ohm continues power handling, 3 x 1" HF Each 180000.00 29.00 5220000.00
on 100° x 15° Horn, passive/ bi-amplification. (Flyable)

Approved make- JBL/EV/MARTIN AUDIO


BOQ of Roller Blind, Back lit Glass, Modular Lockers & Toilets, Acoustic

Quantity Amount
S.No. Description Unit Rate Remarks
DSR Non DSR DSR Non DSR
ii Array Frame for Suspending up to 6 Enclosures with 10:1
Design Factor. Includes 4 x Quick Release Pins, 2 x Shackles, 2 Each 92000.00 9.00 828000.00
x Drop Levers.
Approved make- JBL/EV/MARTIN AUDIO

iii Bass reflex Subwoofer system with 1600 watt long term power
Each 165000.00 19.00 3135000.00
handling, with 2 x 18" LF driver, flyable
Approved make- JBL/EV/MARTIN AUDIO

iv Two-Way Monitor System 80 Hz - 16 kHz (-10dB) frequency


response, 88 dB SPL sensitivity @ 1W / 1m, long term power Each 22000.00 17.00 374000.00
handling 75W, single 5.25" LF and 0.75" HF.
Approved make- JBL/EV/MARTIN AUDIO

v
12" Two-Way Stage Monitor System in a Trapezoidal Enclosure;
400W @ 8 ohm Continues Power Handling, LF 1 x 262H
Each 87000.00 9.00 783000.00
Differential Drive® ;HF 1.5" 1 x 2408H on 70° x 70° Horn;
Passive or Bi- Amplified Operation.
Approved make- JBL/EV/MARTIN AUDIO

(b) AMPLIFIER
i Power amplifier, Dual channel 1500 + 1500 Watts RMS @ 4
ohms, THD<0.05%, damping factor >700 @ 8ohms, Input
Each 110000.00 17.00 1870000.00
CMRR(1khz) <60db, input sensitivity @ 8ohms 1V, with
integrtaed LCD dispaly
Approved make-Crown/QSC/ VP
BOQ of Roller Blind, Back lit Glass, Modular Lockers & Toilets, Acoustic

Quantity Amount
S.No. Description Unit Rate Remarks
DSR Non DSR DSR Non DSR
ii
Power amplifier with 200 W @ 4 ohms per channel power output;
signal to noise ratio <-100dB, Damping factor greater than 200
Each 45000.00 3.00 135000.00
@ 8 ohms, frequency response 20Hz - 20 kHz. Input impedance
20k Ohms (balanced) & 10k Ohms (unbalanced).

Approved make-Crown/QSC/MARTIN AUDIO


iii
Power amplifier with 800 W @ 4 ohms per channel power output;
signal to noise ratio <-100dB, Damping factor greater than 200
Each 67000.00 8.00 536000.00
@ 8 ohms, frequency response 20Hz - 20 kHz. Input impedance
20k Ohms (balanced) & 10k Ohms (unbalanced).

Approved make-Crown/QSC/MARTIN AUDIO

(c ) MIXER & PROCESSOR


i 24 channels Mixing console with 4-Sub-group, 8-Aux sends,
Stereo returns, Direct outputs on every channel (pre/ post
selectable), 4 segment output meters on every channel, Each 325000.00 3.00 975000.00
Switchable 48V phantom powering on every channel, 18dB/
octave high pass filter.
Approved make-Soundcraft/midas/allen & Heath

ii 2-input, 6-output Loudspeaker Management System with digital


display, RTA mic, phantom voltage15v DC, impedance 120 Each 96000.00 8.00 768000.00
ohms, sample rate 48kHz, THD 0.002%.
Approved make-EV/DBX/BSS

(d) MICROPHONE, CD-CASSETTE DECK & ACCESSORIES


i Dynamic Vocal Microphone with cardioid polar pattern, frequency
response 70Hz - 20kHz (@ 1 cm: 20Hz - 18kHz), THD 147/156 Each 14500.00 26.00 377000.00
dB,Impedence <=600 ohms
Approved make-EV/Shure/AKG
BOQ of Roller Blind, Back lit Glass, Modular Lockers & Toilets, Acoustic

Quantity Amount
S.No. Description Unit Rate Remarks
DSR Non DSR DSR Non DSR

ii 50cm gooseneck cardioid Microphone, polar pattern Cardioid,


Frequency Range 70-18,000 Hz, Sensitivity 18mV/Pa, Each 16800.00 4.00 67200.00
Recommended load Impedance >2000 ohms
Approved make-EV/Shure/AKG

iii Dynamic Instrumental Microphone with supercardioid polar


pattern, frequency response 60Hz - 20kHz (@ 1 cm: 20Hz - Each 9200.00 28.00 257600.00
20kHz), THD 147/156 dB.
Approved make-EV/Shure/AKG

iv Proffessional Cd-Cassette player Each 62000.00 3.00 186000.00


Approved make-Tascam/Teac/Denon

v Wiring for system including miscellaneous connectors in PVC


job 275000.00 3.00 825000.00
conduits.

vi Installation, testing and commissioning of Sound reinforcement


job 125000.00 3.00 375000.00
system.
SH 7
GENERAL ILLUMINATION AND EFFECT LIGHTING SYSTEM
1
Providing, fixing & commissioning concealed light fittings in false
ceiling with PAR 38 lamps of 120W including copper wiring in
Each 4800.00 198.00 950400.00
PVC conduits (MD) upto control room and all electrical works to
be executed as per respective individual or specifications.

2 Providing,fixing & commissioning of digital Dimmer in control


room for controlling auditorium lights complete as per drawing & Each 200000.00 3.00 600000.00
to the satisfaction of Engineer-in-charge.
BOQ of Roller Blind, Back lit Glass, Modular Lockers & Toilets, Acoustic

Quantity Amount
S.No. Description Unit Rate Remarks
DSR Non DSR DSR Non DSR
3
Providing,fixing & commissioning of Step lighting and Cove
lighting in coloured LED"s with transformers and controllers
Rmtr. 2650.00 523.00 1385950.00
complete as per drawing & to the satisfaction of Engineer-in-
charge.
4
Providing,fixing & commissioning ofbracket lights with LED's over
chair side stand towards gangways complete as per drawing & to Each 500.00 433.00 216500.00
the satisfaction of Engineer-in-charge.

5
Providing,fixing & commissioning of 5/15amp plug points
complete with metal box, modular plate and switches, including
Each 7000.00 49.00 343000.00
wiring in PVC conduits upto control room complete as per
drawing & to the satisfaction of Engineer-in-charge.

6
Providing,fixing & commissioning of Distribution board on stage
for stage services e.g. stage lights, curtains etc. complete as per Each 325000.00 3.00 975000.00
drawing & to the satisfaction of Engineer-in-charge.

7
Providing,fixing & commissioning of Distribution board in control
room for ceiling lights, EXIT panels, light & power points
Each 250000.00 3.00 750000.00
etc.complete as per drawing & to the satisfaction of Engineer-in-
charge.

8
Providing,fixing & commissioning of Backlit "EXIT" acrylic
signage complete including powder coated housing box and
adequate luminares and wiring complete including mounting as
Each 12000.00 18.00 216000.00
per approved design.With 30 minutes backup facility and
rechargeable battery complete as per drawing & to the
satisfaction of Engineer-in-charge.
SH 8 STAGE FURNISHING
Stage Curtains:
BOQ of Roller Blind, Back lit Glass, Modular Lockers & Toilets, Acoustic

Quantity Amount
S.No. Description Unit Rate Remarks
DSR Non DSR DSR Non DSR
1
Providing and fixing Act Curtain, Centre Parting Horizontal
moving, motorised with min. 1.0 HP,3 phase, 415V 50Hz, AC
motor, complete with Velvet Curtain duly stitched with pleats Each 210000.00 1.00 210000.00
decorative strips, without linning, as required to the satisfaction of
Engineer-in-charge.
2
Providing and fixing Middle and Rear Curtain, Centre Parting
Horizontal moving, motorised with min. 1.0 HP,3 phase, 415V
50Hz, AC motor, complete with Glazed cotton Curtain duly Each 180000.00 2.00 360000.00
stitched with pleats decorative strips, without linning, as required
to the satisfaction of Engineer-in-charge.

3
Providing and fixing Motorized Light/set bars with min. 1.0 HP,3
phase, 415V 50Hz, AC motor, complete with steel ropes to the
Each 75000.00 3.00 225000.00
satisfaction of Engineer-in-charge.
Max. length of bar 10 mtr.

4
Providing and fixing Main Frill bar, fixed type, made out of 42mm
dia GI pipe, supported from ceiling Structure, as required. Frill to
Each 35000.00 1.00 35000.00
be made out of Velvet cloth, stitched with pleats, frills, etc., as
required to the satisfaction of Engineer-in-charge.

5
Providing and fixing Frill bars, fixed type made out of 25mm dia
GI pipe, supported from ceiling structure, As required, Frill to be
made out of Black Glazed Cotton Cloth, stitched with Each 30000.00 4.00 120000.00
pleats,Frills, etc., as required to the satisfaction of Engineer-in-
charge.
BOQ of Roller Blind, Back lit Glass, Modular Lockers & Toilets, Acoustic

Quantity Amount
S.No. Description Unit Rate Remarks
DSR Non DSR DSR Non DSR
6
Providing and fixing Side Wings made out of Black 50x25 mm
MS rectangular tube frame covered with 6 mm thick commercial
Each 35000.00 5.00 175000.00
ply and Black Glazed Cotton Cloth to the satisfaction of
Engineer-in-charge.
7
Fabricating and fixing on the stage cyclorama . Cyclorama to be
fabricated out of tubular framework of MS Tubes section 50 X25
mm square at 600mm c/c bothways; applying 15-20mm
sqm 2200.00 65.00 143000.00
Gypsum plaster over metal lathe secured over the MS frame;
finishing with1 coat of Gypsum base coat & 2 or more cotas of
plastic emulsion paint to the satisfaction of Engineer-in-charge.

8
Fabricating and fixing on the Stage Proescinium to be fabricated
out of tubular framework of MS Tubes section 50 X25 mm
square at 600mm c/c bothways; fixing ANUTONE Sound Slats
on front side and 15-20mm Gypsum plaster over metal lathe sqm 16600.00 65.00 1079000.00
secured over the MS frame on back side including finishing with
2 or more coats of plastic emulsion paintto the satisfaction of
Engineer-in-charge.

9
Providing & Fixing 12mm thick Teakwood flooring over stage
laid over a layer of 65 mm thick ANUTONE Sound Float .The top
sqm 10500.00 98.00 1029000.00
surface to be finished with orbital sanding & polishing with PU
polish to the satisfaction of Engineer-in-charge.

SH 9 STAGE LIGHTING SYSTEM


i
PAR 64 1000Watt, 240 Volts, Shielded beam with 1mtr, 3 core
wire, 15Amp. Plug top & clamp. Make: Each 5000.00 18.00 90000.00
New Stage Craft or equivalent make
BOQ of Roller Blind, Back lit Glass, Modular Lockers & Toilets, Acoustic

Quantity Amount
S.No. Description Unit Rate Remarks
DSR Non DSR DSR Non DSR
ii
Spot Light 1000Watt, with T-11 type lamp &1mtr, 3 core wire, 15
Amp. Plug top & Clamp. Make: New Each 5200.00 9.00 46800.00
Stage Craft or equivalent make

iii
FRESNELS Light 1000Watt, 240 Volts, Halogen Lamp 150 mm
dia Fresnel lens, barn door, 3- core copper wire with 15 amp plug
Each 8700.00 5.00 43500.00
top & Clamp. Make: New
Stage Craft or equivalent make
iv
PROFILE Light, 1000 Watt, 240Volt with 1mtr, 3- core, wire, 15
amp. Plug top & Clamp. Make: Each 8700.00 5.00 43500.00
New Stage Craft or equivalent make
v Halogen Flood, Barn door type with 1000 Watt halogen tube, 1
mtr, 3-core wire,15 amp. Plug top & clamp. Make: Each 2800.00 5.00 14000.00
New Stage Craft or equivalent make

vi
Supply of Motor head light (Spot) strong function spot computer
light, with 9 color + white rotate rainbow effect, 4 metal gobos +
white + 3 glass gobos, rainbow effect, auto rotation of gobos in
both directions, prism effect. DMX 512 Channels: 9 CHS, Color Each 395000.00 2.00 790000.00
temperature: 6500K, Luminous: 22000Lux, Pan / Tilt Movement:
Pan 450 degree; Tilt: 270 degree, 575 W HMI Complete in all
respect as required.

Geni, OBY-5 or Equivalent make.


BOQ of Roller Blind, Back lit Glass, Modular Lockers & Toilets, Acoustic

Quantity Amount
S.No. Description Unit Rate Remarks
DSR Non DSR DSR Non DSR
vii
Supply of DMX controller for programming up to 9 intelligent
lights, 36 channels with 9 projector banks of 4 channels each,
Scene, program & projector LED displays, 9 programs with up to
50 steps per program, fade & speed control, built-in microphone Each 162500.00 1.00 162500.00
for sound active mode Complete in all respect as required.
Neo-Neon Silver Star, SRC-232 or Equivalent make.

viii Cyclorama Lights, with 500 Watt halogen tube and colour film, 1
mtr, 3-core wire,15 amp. Plug top & clamp. Make: Each 4200.00 18.00 75600.00
New Stage Craft or equivalent make

ix
Electronic Dimmer wall mount type 18 Channel X 4 KW per
Channel with patch panel. Make: Each 215000.00 2.00 430000.00
New Stage Craft or equivalent make
48 Channel stage light mixer with programming facility.
x Each 385000.00 1.00 385000.00
xi DMX Cables for Patch panel Each 100.00 33.00 3300.00
xii Light Bars 50mm dia MS Pipe with clamps Rmtr 450.00 21.00 9450.00
xiii Stage side ladders with Clamps Each 7500.00 7.00 52500.00
xiv Making points for Stage Lights with 1.5mm,3-core cables in PVC
Each 5200.00 57.00 296400.00
conduits including 15 amp plugs.
xv
Supplying, Installation, testing & commissioning of Stage lighting
system including miscellaneous connectors & fittings complete job 150000.00 1.00 150000.00
as per drawing & to the satisfaction of Engineer-in-charge.

SH 10 FIRE DETECTION AND SUPPRESSION SYSTEM


1 Pipes & Accessories:
BOQ of Roller Blind, Back lit Glass, Modular Lockers & Toilets, Acoustic

Quantity Amount
S.No. Description Unit Rate Remarks
DSR Non DSR DSR Non DSR

Supply, installation, testing & commissioning of medium grade


M.S. pipe as relevant IS: 1239 with special accessories like tees,
elbows etc. as complete with supporting with primer & p.o. red
paint etc. Complete as required of following sizes: -

a 80 mm dia. mtr 0.00 0.00 0.00

b 100 mm dia. mtr 0.00 0.00 0.00

2 Supply, installation, testing & commissioning of first aid hose reel


full swinging type with 30mtrs. Long 20mm dia rubber lined hose
pipe with shut off nozzle of 5 mm dia the hose reel confirming to Each 0.00 0.00 0.00
IS: 884-1969. Complete as required including 25mm dia. ball
valve as required. (OMEX)

3 Supply, installation, testing & commissioning of air release vessel


of 150 mm dia pipe as complete with air release valve as Each 0.00 0.00 0.00
necessary.

4 Fire Extinguishers
Providing & Fixing with brackets wall mounted fire extinguisher
as per details below:
ABC type fire extinguisher siphon tube, plunger (spring operated)
Each 0.00 0.00 0.00
& discharge tube.
Capacity – 5Kg

5 Supply & Fixing of ABS body Manual call Box with hinge type
Each 0.00 0.00 0.00
transparent cover. (Agni suraksha)
6 Supply, Fixing & commissioning of Wall mounted acoustically
Each 0.00 0.00 0.00
treated box with 4-watt speaker. (Agni suraksha)
BOQ of Roller Blind, Back lit Glass, Modular Lockers & Toilets, Acoustic

Quantity Amount
S.No. Description Unit Rate Remarks
DSR Non DSR DSR Non DSR
7 Supply, Fixing & commissioning of Ionisation type smoke
Each 0.00 0.00 0.00
detector.(Below false ceiling) (Apollo-U.K)
8 Supply, Fixing & commissioning of Optical type smoke detector.
Each 0.00 0.00 0.00
(above false ceiling) (Apollo-U.K) or equivalent make
9 Providing, fixing, testing and commissioning of 2 Zone Manual
Main Fire Alarm Panel (window type), relay for actuation of
Each 0.00 0.00 0.00
hooter sealed maintenance free batteries of 15 Ah capacity of 24
volts. (Agni suraksha or equivalent make)
10 Supply & fixing of PVC Conduit of 20 mm dia along with the
mtr 0.00 0.00 0.00
accessories as complete as required.
11 Providing & fixing of wires of 1.5 sq.mm.(FRLS) mtr 0.00 0.00 0.00
12 Supply, installation, testing & commissioning of response
Each 0.00 0.00 0.00
indicator.
Pump & Accessories
13
Supplying, installing, testing, & commissioning of electric driven
Terrace pump of 900 LPM monoblock type, 7.5 HP, 30M.H.,
2900 R.P.M as complete with concrete base, angle frame, anti- Each 0.00 0.00 0.00
vibration pad etc. as required according to as specified in the
quotation. (Main Pump)---KIRLOSKAR or equivalent make

14 Supplying, testing, installation & commissioning of pressure


switches for Terrace Pump complete with 2 x 1.5 sq. mm-
Each 0.00 0.00 0.00
unarmored cable, clamping and terminations complete as
required.
15 Supplying, testing, installation & commissioning of Hydrant
Each 0.00 0.00 0.00
Valve.(ISI MARKED)
16 Supplying, testing, installation & commissioning of RLL Hose
Each 0.00 0.00 0.00
(ISI MARKED)
17
Supplying, testing, installation & commissioning of Hose Boxes. Each 0.00 0.00 0.00
BOQ of Roller Blind, Back lit Glass, Modular Lockers & Toilets, Acoustic

Quantity Amount
S.No. Description Unit Rate Remarks
DSR Non DSR DSR Non DSR
18 Supplying, testing, installation & commissioning of Branch pipe.
Each 0.00 0.00 0.00
(ALU.)

Valves & Accessories.


19 Supplying, testing, installation & commissioning of butter fly
Valves as complete with Flanges etc. of following sizes: -
(Castle/C&R)
a 100 mm dia Each 0.00 0.00 0.00
b 80 mm dia. Each 0.00 0.00 0.00
c 50 mm dia Each 0.00 0.00 0.00
20 Supplying, testing, installation & commissioning of Non Return
Valves as complete with Flanges etc. of following sizes: -
(Castle/C&R)
a 100 mm dia Each 0.00 0.00 0.00
b 50 mm dia Each 0.00 0.00 0.00

ELECTRICAL
21 Fabricating, supplying, erection, testing and commissioning of
totally enclosed cubicle type wall mounted panel suitable for Each 0.00 0.00 0.00
specified pump. (Automation)
22 Supplying and fixing of one number PVC insulated and PVC
sheathed / XLPE aluminium conductor cable of 1.1 KV grade of
size not exceeding 25 sq mm on surface as required. (PUMP TO
PANEL/MCC)
10 Sq mm X 4 core. mtr 275.00 9.00 2475.00
23 PVC Tank Capacity – 20000 ltrs. FIRE tank at terrace. As
complete with concrete or angle framed bases complete as job 0.00 0.00 0.00
required.
TOTAL OF ACOUSTIC 94661875.00
Balance work for Construction of ESIC Medical College and Hospital at Bihta ,Patna(Bihar)

SUMMARY SHEET (Combined Package of Fire Fighting Works)

SUBHEAD DESCRIPTION DSR NON DSR TOTAL

A Fire Pumps & Equipments 1,755,824.00 1,755,824.00

B Piping, Hydrants & Accessories 73,192,248.00 73,192,248.00

Total Cost (In Rs.) 74,948,072.00


Balance work for Construction of ESIC Medical College and Hospital at Bihta ,Patna(Bihar)

Fire Fighting works

Quantity Amount

S.N. Description Rate Unit Remarks


DSR Non DSR DSR Non DSR

1 2 3 4 5 6 7 8 9

Sub Head-A : Fire Pumps & Equipments (Down Comer System)

1 Providing, fixing, testing and commissioning of pressure vessel (450 mm dia &
2000 mm height) for pressurization of fire system complete with pressure
switches with isolation valves, pressure gauge with isolation valve, valves at
outlet / drain to operate as per operating sequences including 25 mm dia
drain valve, air release valve with stop cock on the top Duly painted from
inside and outside complete as required.

32,912.00 Sets 2 65,824.00


-
2 Supply (installation, testing and commissioning) of electrically driven fire,
sprinkler pump, suitable for automatic operation consisting of the following :
-
-
a) Horizontally mounted end suction centrifugal pump, suitable for operation on
415 volts ± 10%, 3 phase, 50 HZ A.C supply, complete with flexible coupling
and coupling guard as required. Fire pump having C.I. body, bronze
impeller and S.S. Shaft with mechanical seal, capable for delivering
2280Lpm water at 85 mts.head to ensure a minimum pressure of 3.5kg/cm2 at
the farthest hydrant. Complete with necessary pressure gauge with gun metal
shut off cock on delivery side. The pump should meet the condition of Local
fire Authority).

-
-
b) Squirrel cage induction motor, TEFC type suitable for operation on 415 volts, 3
phase 50 HZ A.C supply, for the above pump with synchronous speed of
2900 RPM. -
-
c) Common base plate for (a) and (b) from M.S. Channel for required size. -
-
d) Suitable cement concrete foundation with cement concrete plaster complete
with antivibration arrangement of cushy foot mountings.
280,000.00 Sets 3 840,000.00
-
Fire Fighting works

Quantity Amount

S.N. Description Rate Unit Remarks


DSR Non DSR DSR Non DSR

3 Supply, installation, testing and commissioning of Down Comer pump of


electrical-operated of capacity 900 LPM of water at 35 mts.Head to ensure a
minimum pressure of 3.5kg/cm2 at the farthest hydrant with pressure switch.

4 Supply, installation, testing and commissioning of Diesel Engine driven fire


pump suitable for automatic operation comprising of the following :
-
-
a) Horizontally mounted end suction centrifugal pump, suitable for operation on
415 volts ± 10%, 3 phase, 50 HZ A.C supply, complete with flexible coupling
and coupling guard as required. Fire pump having C.I. body, bronze
impeller and S.S. Shaft with mechanical seal, capable for delivering 2280
LPM of water at 85 mts.head to ensure a minimum pressure of 3.5kg/cm2 at
the farthest hydrant. Complete with necessary pressure gauge with gun metal
shut off cock on delivery side. The pump should meet the condition of Local
fire Authority).

-
-
b) Water Coolad Diesel engine of speed 1800 RPM for the above pump with
automatic starting mechanism and other accessories including fuel tank
(fabricated from 3mm MS sheet painting with two coats of synthetic enamel
paint over a coat of primer) capacity 600 Its (fitted with Magnetic oil level
indicator, MH with cover drain valve, Air vent hydraulic pumps including
structural supports (painted with approved shade), 2 Nos. x 12 volt battery,
heat exchanger with necessary piping connections & fittings flexible coupling,
coupling guard & exhaust pipe as per drawing complete as required.

-
-
c) Common base plate for (a) and (b) from M.S. channel of required size. -
-
d) Suitable cement concrete foundation with plaster, Antivibration arrangement
of cushy foot mountings -
-
e) 24 volts, 180 AH Lead battery - Exide make ( 12 volts-2 Nos) with boost /
trickle charger for starting the engine automatically as required. 550,000.00 Set 1 550,000.00
-
5 Supply, installation, testing and commissioning of jockey pump comprising of
the following : -
-
Fire Fighting works

Quantity Amount

S.N. Description Rate Unit Remarks


DSR Non DSR DSR Non DSR

a) Horizontally mounted end suction centrifugal pump, suitable for operation on


415 volts ± 10%, 3 phase, 50 HZ A.C supply, complete with flexible coupling
and coupling guard as required. pump having C.I. body, bronze impeller
and S.S. Shaft with mechanical seal, capable for delivering 180 LPM of water
at 85 mts.head to ensure a minimum pressure of 3.5kg/cm2 at the farthest
hydrant. Complete with necessary pressure gauge with gun metal shut off cock
on delivery side. The pump should meet the condition of Local fire Authority).

-
-
b) Squirrel cage induction motor TEFC type for operation on 415 V, 3 phase 50
HZ AC supply for the above pump with a synchronous speed of 2900
R.P.M. with flexible coupling and coupling guard etc. as required.
-
-
c) Common base plate for (a) and (b) from M.S. channel as required size. -
-
d) Suitable cement concrete foundation with plaster, Antivibration arrangement
of cushy foot mounting. 150,000.00 Set 2 300,000.00
-
6 Fire Fighting Panels:- -
Supply Installation testing and commissioning of following items including inter
connections:- -
a) Fully automatic Star- Delta Motor Starter for 10 HP, 3 Phase down comer
pump in sheet steel enclosure:-
b) 32 A TP MCB Isolator in sheet steel enclosure

7 Fire Fighting Pump Panel


A INCOMER -
i) 1No. 500A TP&N MCCB(35 KA) -
B METERING & INDICATION -
i) 1 set of phase indicating lamps -
ii) 1 set of Voltmeter (0-500V) with Built-in VSS with 3 nos. 2A SP MCB -
iii) 1 set Ammeter (0-500A) with ASS and 3 nos.500/5A, CT's
-
C BUS-BAR -
i) 1 Set of 600A TPN Aluminium Bus Bar with colour coded PVC Sleeves -
D OUTGOINGS -
i) 2 Nos. 250A TP MCCB (35 KA) -
ii) 2 No. 63A TP MCB (10 KA) C curve -
iii) 2 No. 25A DP MCB (10 KA) C curve -
iv) 2 Nos. of S/D starter with self illuminated Push button for ON & OFF and
suitable rating of contactor and O/L relays, suitable for 90 HP Pump.
-
Fire Fighting works

Quantity Amount

S.N. Description Rate Unit Remarks


DSR Non DSR DSR Non DSR

v) 1 No. DOL starter with self illuminated Push button for ON & OFF and suitable
rating of contactor and O/L relays, suitable for 7.5 HP Motor.
-
NOTE : The starters of Fire Fighting Pump shall be interlocked with the fire
alarm panel & Axial flow fan to start these fans in case of fire -
8 Supply of Fire Fighting Pump Panel as described above
9 Receiving, fixing, testing & commissioning of Fire Fighting Pump Panel
as described above
-
Note:
Contractor shall include in his rates for providing level controllers, switches,
wiring, cabling from level controller to panel etc. complete as required to
operate the system automatic/manual and pump shall be protected against
running dry. -
TOTAL Sub Head A 1,755,824.00

Sub Head-B : Piping, Hydrant and Accessories System


1 Providing, laying, jointing and testing of following sizes of pipes conforming to
IS-1239 with all accessories like all fittings including tees, elbows, reducers,
flanges, rubber gaskets, nuts bolts, washer. And fixing the pipe on floor / wall
/ceiling with suitable size clamps, hangers, structural steel supports as per
specification. And G.I. pipe sleeve to be provided wherever the pipes are
crossing the walls/floors and sealing the sleeves as per consultants
requirements including cutting holes and chases in brick, R.C.C work and
making good the same to original conditions complete in all respects. Pipe
shall be MS black as per IS-1239 heavy grade and fitting for 40 mm and below
be of galvanised iron screwed fittings and above BW 'C' class fittings

For Fire System - M.S. `C' Heavy class pipe


a) 25 mm dia 262.00 RM 30575 8,010,650.00
b) 32 mm dia 339.00 RM 2786 944,454.00
c) 40 mm dia 390.00 RM 4205 1,639,950.00
d) 50 mm dia 477.00 RM 5345 2,549,565.00
e) 65 mm dia 494.00 RM 1568 774,592.00
f) 80 mm dia 884.00 RM 2535 2,240,940.00
g) 100 mm dia 1,286.00 RM 3062 3,937,732.00
h) 150 mm dia 1,895.00 RM 5555 10,526,725.00
Fire Fighting works

Quantity Amount

S.N. Description Rate Unit Remarks


DSR Non DSR DSR Non DSR

-
2 Providing two coats of synthetic enamel paint of approved shade over a coat
of primer. Including painting of legends both direction arrow as per the
approval of the architects / consultants. -

a) 25 mm dia 5.00 RM 30575 152,875.00


b) 32 mm dia 7.00 RM 2786 19,502.00
c) 40 mm dia 8.00 RM 4205 33,640.00
d) 50 mm dia 10.00 RM 5345 53,450.00
e) 65 mm dia 11.00 RM 1568 17,248.00
f) 80 mm dia 14.00 RM 2535 35,490.00
g) 100 mm dia 16.00 RM 3062 48,992.00
h) 150 mm dia 25.00 RM 5555 138,875.00
-
3 Providing, laying, jointing and testing in trenches the following sizes of M.S.
class `C' (heavy class) pipes conforming to IS:1239 with accessories like
fittings including tees, elbows, reducers, flanges, rubber gaskets, G.I. nuts,
bolts and washers and providing 150mm thick fine sand layer all around the
pipe, including excavation in all kind of soil/ hard rock, refilling, ramming and
removing the excavated surplus material and making good the same complete
as required.and providing anti corrosive treatment (coating and wrapping) with
4 mm thick anti corresive tape as per IS :10221 complete as required. (for -
external works)

a) 80 mm dia 1,310.00 RM 180 235,800.00


b) 150 mm dia 2,150.00 RM 5242 11,270,300.00
-
4 Providing and fixing Chrome finish quartzoid bulb sprinklers of size 15mm dia
(Pendant / upright / side wall) to be Operated at 68 Deg C. Including two
piece of adjustable C.P. Rosset complete as required. -

350.00 Nos. 13022 4,557,700.00


-
5 Providing and fixing gun metal ball valve suitable for pressure 15 Kg/Cm2 and
confirming to IS: 778 of the following size including providing necessary -
union / flange.
a) 25 mm dia 815.00 Nos. 486 396,090.00
b) 32 mm dia 1,388.00 Nos. 1 1,388.00
c) 40 mm dia 1,782.00 Nos. 1 1,782.00
d) 50 mm dia 2,716.00 Nos. 2 5,432.00
Fire Fighting works

Quantity Amount

S.N. Description Rate Unit Remarks


DSR Non DSR DSR Non DSR

-
6 Providing & fixing of butterfly valve suitable for pressure 15 Kg/Sqcm. with
-
flanges, nut bolts & gaskets complete required.
a) 65 mm dia 2,207.00 Nos. 4 8,828.00
b) 80 mm dia 2,369.00 Nos. 21 49,749.00
c) 100 mm dia 3,082.00 Nos. 32 98,624.00
d) 150 mm dia 6,895.00 Nos. 209 1,441,055.00
e) 200 mm dia 13,766.00 Nos. 4 55,064.00
-
7 Providing & fixing cast iron Slim seal dual type non-return valves (PN 1.6)
complete with matching flanges, rubber insertion, nuts, bolts and washer
complete as required.etc. of following sizes. -

a) 100 mm dia 7,054.00 Nos. 2 14,108.00


b) 150 mm dia 15,577.00 Nos. 53 825,581.00
-
8 Providing & fixing 150 mm dia installation Control Valve assembly comprising
of vertical wet alarm valve, including 150 mm butterfly valve, hydraulic alarm
motor & gong , 15 mm dia .Test valve and all necessary trimming connections
including 2 nos. pressure gauge as per manufacturer ‘s catalogue
-
(UL/FM/LPC/TAC listed approved).

a) 150 mm dia 45,000.00 Nos. 3 135,000.00

9 Providing & fixing single action air release valve with brass gate valve,
flanges/union , suitable for sprinkler/wet riser system with all necessary
connections

-
10 Providing & fixing Air Cushion tank (Air - vessel) 250 mm dia x 1.0 M high with
dished top made of minimum 6 mm thick M.S Sheet pipe/ plate complete with
25 mm dia brass .Air Valve (Ball type) 25 mm dia stopcock. Nipple tees.
Elbows and all accessories as required including fixing brackets. -

a) 25 mm dia 15,000.00 Nos. 59 885,000.00


-
11 Providing & fixing double flanged flexicon rubber expansion joint with unit
control of standard length as per maufacturers specs. Tested to a pressure of
15Kg/Sqcm including rubber gaskets, flanges, nuts, bolts and washers -
complete as required.
Fire Fighting works

Quantity Amount

S.N. Description Rate Unit Remarks


DSR Non DSR DSR Non DSR

a) 65 mm dia 3,700.00 Nos, 2 7,400.00


b) 80 mm dia 4,400.00 Nos, 1 4,400.00
c) 100 mm dia 5,050.00 Nos, 3 15,150.00
d) 150 mm dia 6,300.00 Nos, 17 107,100.00
-
12 Providing and fixing C.I. 'POT' strainer with bronze perforated sheet
basket tested to a pressure of 15 Kg/sqcm including rubber gasket,
flanges, nuts, bolts and washers, complete as required. -

a) 150 mm dia 26,025.00 Nos. 0 -


b) 200 mm dia 26,025.00 Nos. 2 52,050.00
-
13 Supply, Installation, Testing & Commissioning of single headed, Gunmetal ISI
marked oblique pattern hydrant landing valve with 80 mm dia flange inlet and
63 mm dia instantaneous type female out let complete with gunmetal cap and
G.I chain twist release type plug and all accessories as per IS:5290-1983 3,066,880.00
(Type A)

5,990.00 Each 512


-
14 Providing & fixing swinging type First Aid hose reel in red colour with 36
mts long and 20 mm dia heavy duty rubber water hose, 20 mm dia globe
valve stop cock, terminating with G.M. coupling & nozzle of 5mm outlet with
shut off valve confirming to IS 8090 - 1976 complete with drum and brackets
for fixing on wall, bolts & nuts conforming to IS:884-1969 complete as required. 3,401,040.00

7,660.00 Nos. 444


-
15 Providing & fixing Controlled Percolating (CP) Hose ISI marked (IS:8423) 63
mm dia x 15 m long complete with instantaneous type gunmetal 63 mm dia ISI
marked Male & Female couplings (IS:903) bound and riveted to hose pipe with
copper rivets and 1.5 mm copper wire.brusting pressure not less than 22 475,728.00
Kg/Sqcm. (two nos. for each hydrant-valve)

3,498.00 Each 136


-
16 Providing & fixing Non per colating flexible hose (RRL type – A) ISI marked
(IS:636 Type A) 63 mm dia x 15 m long complete with ISI marked Male and
female coupling (IS:903) bound and riveted to hose pipe with copper rivets and
1.5 Sq.mm.copper wire.brusting pressure not less than 22 Kg/Sqcm. (two
3,536,016.00
nos. for each hydrant-valve)

3,982.00 Each 888


Fire Fighting works

Quantity Amount

S.N. Description Rate Unit Remarks


DSR Non DSR DSR Non DSR

-
17 Providing & Fixing Gun-metal 63 mm dia short size branch pipes with 20 mm
1,536,512.00
dia nozzle with 63 mm instantaneous coupling ISI marked (IS:903) 3,001.00 Each 512
-
18 Providing and fixing standard firemans axe with heavy rubber handle. 1,411.00 Nos. 512 722,432.00
-
19 Providing and fixing inlet breeching having C.I. body Two way gun metal 63
mm dia instantaneous inlets conforming to IS 903 fitted with non return valves,
25 mm dia gun metal drain cock, blank cap, brass chains and 150 mm dia
flanges with all accessories suitable for local fire tender complete as required
138,510.00
in Down Comer Riser

4,617.00 No. 30
-
20 Providing and fixing inlet breeching having C.I. body four way gun metal 63
mm dia instantaneous inlets conforming to IS 903 fitted with non return valves,
25 mm dia gun metal drain cock, blank cap, brass chains and 150 mm dia
flanges with all accessories suitable for local fire tender complete as 36,938.00
required.

18,469.00 Nos. 2
-
21 Providing & fixing Gunmetal fire Bridge Suction hose coupling (Draw out
Connection) with nut for100mm dia female coupling as per IS:902-1974 etc. 9,235.00
complete as required. 9,235.00 Each 1
-
22 Providing & fixing Gunmetal fire Bridge Suction hose coupling (Draw out
Connection) with nut for female coupling as per IS:902-1974 complete with
100mm dia. 1 No C.I Foot valve flanged (to be connected to static water tank) 42,300.00
21,150.00 Each 2
-
23 Providing and fixing weather proof cabinet of size not less than 0.75 x 0.6 x
0.25 mtr made out of M.S. sheet not less than 1.5 mm thick having central
opening and 4 mm thick glazed glass doors (Two nos.) suitably marked on
the outside 'with the letters "FIRE HOSE" including necessary locking
arrangement and painting in red colour suitable to accommodate, external
yard hydrant valve, 2 nos 15 mtr long Hose pipe, branch pipe, nozzle and fire 445,400.00
man's axe. It shall be mounted on boundary wall complete as required.

6,550.00 Nos. 68
-
Fire Fighting works

Quantity Amount

S.N. Description Rate Unit Remarks


DSR Non DSR DSR Non DSR

24 Providing and fixing 4mm thick glass door of size 2.1m x 0.9m with MS frame
of size 0.10 x 0.05 M with centre opening for fire hose cabinet. Suitable
marked on the outside with the letters "FIRE HOSE" including locking
arrangement. All MS work to be in Red P.O. colour. 3,251,412.00

7,323.00 Nos. 444


-
25 Providing and fixing suction & delivery headers of required length fabricated
from 6mm thick M.S. rolled and welded pipe suitable for 15 Kg/Sqcm working
pressure with end flange connections having inlet&outlet flanged connections
as per drawing. 150 mm dia pressure gauge with stop cock. Including
supports from wall, floors & ceiling complete as required. -

a) 150 mm dia 1,895.00 RM 220 416,900.00


b) 100 mm dia 1,286.00 RM 160 205,760.00
c) 80 mm dia 884.00 RM 140 123,760.00
d) 200 mm dia 2,464.00 RM 30 73,920.00
e) 250 mm dia 3,535.00 RM 30 106,050.00
-
26 Providing and laying Cement concrete for anchor / thrust blocks of 1:4:8
[1 cement : 4 fine aggregate : 8 coarse aggregate, 40 mm nominal size as 280,000.00
per standard design. 3,500.00 Cum 80
-
27 Providing and fixing Fire Extinguishers (A, B, C type powder) complete with
-
all accessories as per manufacturers specifications.
a) Capacity 2 Kg 1,427.00 Nos. 698 996,046.00
b) Capacity 5 Kg 2,283.00 Nos. 542 1,237,386.00
d) Capacity 10Kg 3,425.00 Nos. 116 397,300.00
-
28 ISI marked fire extinguisher Mech. Foam type capacity 50 litres with gunmetal
cap and nozzle, trolly mounted and complete in all respects including initial fill. 220,454.00
16,958.00 Each 13
-
29 ISI marked (IS: 10204) portable fire extinguisher Mech. Foam type capacity 9
litres with gunmetal cap and nozzle and complete in all respects including initial 156,214.00
fill and wall suspension. 2,111.00 Each 74
-
30 Fire Extinguisher 25Kg Capacity ISI Mark IS 10658 Mounted on Trolley Wheel
with G.M Cap Hose CO2 Gas Cartridges ISI Mark Powder ISI Mark IS 4947 &
ISI Mark Powder IS 4308 Complete in all respect. 143,916.00
11,993.00 Nos. 12
-
Fire Fighting works

Quantity Amount

S.N. Description Rate Unit Remarks


DSR Non DSR DSR Non DSR

31 Providing and fixing electricaly operated flow indicating switches model


System Sensor in sprinkler branch line on each floor with necessary junction
box installed in accessible place (Wiring from switches to panel and stair case
-
pressurisation not included)

a) 80 mm dia 5,000.00 Each 6 30,000.00


b) 100 mm dia 7,000.00 Each 6 42,000.00
c) 150 mm dia 7,500.00 Each 64 480,000.00
-
32 Providing and fixing dial type pressure gauge with isolation cock and copper
pipe on main header Dial diameter 100 mm celebration 0-14 / sq. cm. 129,600.00
800.00 Nos. 162
-
33 Providing & fixing 2 zone working +1 standby enunciator Panel for flow control
switches providing Audio / Visual indication of actuation of automatic Sprinkler
system or each zone complete as per specifications. The panel should have 20,000.00
interface for connection to complete controlled building management system.
20,000.00 Set 1
-
34 Providing & fixing 28zone working +6 standby enunciator Panel for flow
control switches providing Audio / Visual indication of actuation of automatic
Sprinkler system or each zone complete as per specifications. The panel 75,000.00
should have interface for connection to complete controlled building
management system. 75,000.00 Set 1
-
35 Providing & fixing cast iron foot valve complete with flange.-150mm dia. 10,000.00 Nos. 1 10,000.00
-
36 Providing and fixing four bucket stand incluiding four nos. buckets and sand for
93,258.00
internal fire protection Complete as required. 1,413.00 Sets 66
TOTAL Sub Head B 73192248.00
Balance work for Construction of ESIC Medical College and Hospital at Bihta ,Patna(Bihar)

SUMMARY SHEET of FIRE ALARM

SUB
DESCRIPTION DSR Non DSR Total
HEAD

Addressable Fire Alarm


I 3370027.00 61029679.00 64399706.00
System

II Public Address System 3130590.00 4401354.00 7531944.00

III CCTV Surveillance System 234850.00 1951109.00 2185959.00

Total 6735467.00 67382142.00 74117609.00

22% on DSR Items 1481802.74 1481802.74

Grand Total 8217269.74 67382142.00 75599411.74


Balance work for Construction of ESIC Medical College and Hospital at Bihta ,Patna(Bihar)

Balance work for Intelligent Analogue Addressable Fire Detection & Alarm System

Quantity Amount
S.No. Description Unit Rate Remarks
DSR NON DSR DSR NON DSR
1 2 3 4 5 6 7 8 9

NON DSR

A Supply, installation testing and commissioning of the


following as per specification
1 Analogue addressable type Multi Sensor combined
photoelectric smoke and rate of rise type heat detector
including mounting base with LED etc. complete as required. Each 3,626.00 3726 13,510,476.00

2 Analogue addressable photo electric smoke detector


including mounting base with LED etc. complete as required. Each 3,417.00 2540 8,679,180.00
-
3 Analogue addressable Rate to rise tempreture(thermister) type
Heat detector including mounting base with LED etc.
complete as required. Each 2,995.00 7 20,965.00
-
4 Analogue Addressable manual call point as per specification Each 3,154.00 108 340,632.00
-
5 Addressable Multisensor with inbuilt fault Isolator for
isolating shorted,dewired and loose circuits between two
successive fault with automatic resetting arrangement Each 5,159.00 167 861,553.00
-
6 Addressable control modules for controlling AHU's and fire
damper, pressurization fan etc. Each 3,365.00 353 1,187,845.00
-
7 a) Addressable monitor module Each 3,206.00 255 817,530.00
b) Addressable Fault Isolator Each 3,206.00 129 413,574.00
-
8 Analogue Addressable Piezo electric Hooters/ Sounders
including Control Module (If required) complete with
ceiling/wall mounting arrangements

Each 5,336.00 129 688,344.00


Balance work for Intelligent Analogue Addressable Fire Detection & Alarm System

Quantity Amount
S.No. Description Unit Rate Remarks
DSR NON DSR DSR NON DSR
-
9 Water flow/damper supervisory switch with 2 NO + 2NC
auxiliary contact
Each 3,035.00 255 773,925.00

-
10 Response Indicator as per specification Each 134.00 2874 385,116.00

-
11 Microprocessor based 2 loops analogue addressable type
fire alarm control panel with not less than 140 addreses, 80
character LCD display, four access levels. 400 event historical
logging & flash, lift shaft and lift lobby pressurization fans,
ventilation fans at fire pump room monitoring of fire sprinkler
and fire hydrant pumps, 240 volts AC power supply,
automatic battery charger, 24 volts sealed lead acid batteries
sufficient for 24 hours normal working and then be capable of
operating the system for 2 hours during and emergency
condition and shall be compatable with BMS Software.(Note:
The bidder can quote a diferent configuration/ no. of loop
Panels as per their panel/equipment design but they must
accomondate the no. of detectors & devices mentioned in the
items above with twenty percent surplus capacity for
expansion)

Each 72,007.00 4 288,028.00


-
12 Repeater Panel for the above 2 Loops panel, 80character
back lit LCD display with complete system function keys for
programing and control like system reset , alarm
acknowledge, alarm silence, trouble acknowledge etc. and
LED indicated Mimic diagram as required.
Each 33,868.00 4 135,472.00
-
Balance work for Intelligent Analogue Addressable Fire Detection & Alarm System

Quantity Amount
S.No. Description Unit Rate Remarks
DSR NON DSR DSR NON DSR
13 Microprocessor based 8 loops analogue addressable type
fire alarm control panel with not less than 140 addreses, 80
character LCD display, four access levels. 400 event historical
logging & flash, lift shaft and lift lobby pressurization fans,
ventilation fans at fire pump room monitoring of fire sprinkler
and fire hydrant pumps, 240 volts AC power supply,
automatic battery charger, 24 volts sealed lead acid batteries
sufficient for 24 hours normal working and then be capable of
operating the system for 2 hours during and emergency
condition and shall be compatable with BMS Software.(Note:
The bidder can quote a diferent configuration/ no. of loop
Panels as per their panel/equipment design but they must
accomondate the no. of detectors & devices mentioned in the
items above with twenty percent surplus capacity for
expansion)

Each 280,769.00 7 1,965,383.00


-
14 Repeater Panel for the above 8 Loops panel, 80character
back lit LCD display with complete system function keys for
programing and control like system reset , alarm
acknowledge, alarm silence, trouble acknowledge etc. and
LED indicated Mimic diagram as required.
Each 33,868.00 7 237,076.00
-
15 Providing, fixing, testing and commissioning of Manual
Break glass type call box made of 16 SWG CRCA Sheet and
having chrome plated hammer 1. Providing, fixing, testing
and commissioning of Manual Break glass type call box made
of 16 SWG CRCA Sheet and having chrome plated hammer
and chain etc. complete as specified.

Each 721.00 181 130,501.00


-
16 Providing, Installing, Testing and commissioning of
electronic alarm sounders on the surface of wall or false
ceiling connections etc. complete as specified. Each 1,075.00 181 194,575.00
-
Balance work for Intelligent Analogue Addressable Fire Detection & Alarm System

Quantity Amount
S.No. Description Unit Rate Remarks
DSR NON DSR DSR NON DSR
17 Providing, fixing testing and commissioning of Local Control
panel of following number of zones, strictly as per IS-2189,
without battery, without power supply. The operating supply
to the local control panel system shall be fed from main
control panel. Each and every zone shall have visual
indications like – isolation, fire, open circuit in detector circuit
short circuit in detector circuit, fire alarm acknowledged,
additionally each and every zone shall have the following
switches- isolation fire test, open circuit test, short circuit test,
fire alarm acknowledge, fault alarm acknowledge, lamp test,
panel system switch etc. as required. The panel shall be wall
mounted, and enclosure shall be made of 16 SWG CRCA
sheet steel and having front door lock and key etc. complete
as specified

-
a) 6 Zones Each 21,058.00 6 126,348.00
b) 8 Zones Each 26,336.00 10 263,360.00
c) 10 Zones Each 28,975.00 6 173,850.00
d) 20 Zones Each 42,700.00 2 85,400.00
-
18 Supply, and fixing of following sizes 500V grade Mineral
Insulated Copper conductor Fire Survival with outer sheathed
Copper cable approved by LPCB and as per IEC60331, BS
5839-1, BS 6387 and BS 7346 standard along with
accessories/ termination/glands asper BS EN 60702 Part 2 and
all necessary material to complete the Termination. The cable
can sustain 950degree temp for three hours.

-
a) 2C x 1.5 sqmm MICC cable RM 469.00 63434 29,750,546.00
-
DSR Items
Balance work for Intelligent Analogue Addressable Fire Detection & Alarm System

Quantity Amount
S.No. Description Unit Rate Remarks
DSR NON DSR DSR NON DSR
19 Supply, and fixing of 16 gauge, MS conduits in following
sizes including cost of junction boxes, bends, elbows, sockets,
tees and MS flexible conduit to connect from ceiling to false
ceiling etc. laying in slab, cutting chases and making good or
surface mounted including all fixing hardware.
a) 20 mm dia- (DSR-2007 1.20.1 STLCON) RM 77.00 27381 2108337
b) 25 mm dia- (DSR-2007 1.20.2 STLCON) RM 86.00 2165 186190

20 Providing and drawing following sizes of FR P.V.C. insulated


copper conductor cable in existing surface/recessed conduit
as required.
a) 2X1.5 sqmm - (DSR-2007 1.17.2 WGEC) RM 25.00 43020 1075500
TOTAL AMOUNT 3370027 61029679

Balance work for Public Address System

NON DSR

Supply installation testing and commissioning of the


1 following as per specification
Recess mounted Speakers equivalent to Philips cat
No.LBD8353 (6 Watts Read Power) including linematching Nos. 711.00 2804 1,993,644.00
transformer ceiling recessed mounting in false ceiling with
clamp complete as required.(PHILIPS/AHUJA)
2 Out door type Speakers equivalent to Philips cat No.LBD8353
(15 Watts Read Power) including linematching transformer Nos. 2,219.00 88 195,272.00
Wall Mounted with clamp complete as required
(PHILIPS/AHUJA)
-
3 AMPLIFIER -
3a 1 x 160 W PA Amplifier complete with Rack of suitable size
and 4 channel mixer , 5 band Grafic qualizer complete with
internal wiring including MS Painted Rack as required. 10,771.00 1 10,771.00
(PHILIPS/AHUJA)
-
Balance work for Intelligent Analogue Addressable Fire Detection & Alarm System

Quantity Amount
S.No. Description Unit Rate Remarks
DSR NON DSR DSR NON DSR
3b 1 x 350 W PA Amplifier complete with Rack of suitable size
and 4 channel mixer , 5 band Grafic qualizer complete with
internal wiring including MS Painted Rack as required. 17,974.00 5 89,870.00
(PHILIPS/AHUJA)
-
3c 1 x 750 W PA Amplifier complete with Rack of suitable size
and 4 channel mixer , 5 band Grafic qualizer complete with
internal wiring including MS Painted Rack as required. No. 34,631.00 27 935,037.00
(PHILIPS/AHUJA)
-
4 Four channel Audio mixer with Goose neck call station inside
the Security room or in control room complete as required.
(equivalent to Philips cat No.LBB 1950or /AHUJA) No. 4,630.00 9 41,670.00

-
5 Wireless microphone complete with all assoseries as required
(Optional).(PHILIPS/AHUJA) Nos. 1,780.00 10 17,800.00
-
6a Zone Selection Switch Including 6 zones through Selector
Switch.(PHILIPS/AHUJA) -
-
6b Zone Selection Switch Including 12 zones through Selector
Switch.(PHILIPS/AHUJA) No. 18,390.00 11 202,290.00
-
7 Moduler type Volume controller in MS Box complete with
inter connection as required. No. 1,000.00 915 915,000.00

DSR Items
1 Supply, and fixing of 16 gauge, MS conduits in following
sizes including cost of junction boxes, bends, elbows, sockets,
tees and MS flexible conduit to connect from ceiling to false
ceiling etc. laying in slab, cutting chases and making good or
surface mounted including all fixing hardware.
a) 20 mm dia- (DSR-2007 1.20.1 STLCON) RM 77.00 28920 2226840

2 Providing and drawing following sizes of FR P.V.C. insulated


copper conductor cable in existing surface/recessed conduit
a) as required.
2X1.5 sqmm - (DSR-2007 1.17.2 WGEC) RM 25.00 36150 903750
Balance work for Intelligent Analogue Addressable Fire Detection & Alarm System

Quantity Amount
S.No. Description Unit Rate Remarks
DSR NON DSR DSR NON DSR
TOTAL AMOUNT 3130590 4401354

Balance work for CCTV Surveillance System

NON DSR

1 Supply installation testing and commissioning of the


following as per specification
1/3" day and night indoor mini Dome color Camera, 530 TV
Lines, 0.002 Lux with 3m fixed iris lens.
Nos. -

2 1/3" day and night indoor 3 axis Dome color Camera, Pan
/Tilt, 570 TV Lines, 0.002 Lux with f = 3-9mm 3X Veri-focal Nos. 15,248.00 60 914,880.00
lens. -
3a 4 Channel Real time Digital Vedio Recorder, 4 loop through
vedio output Respectively, TCP/IP Connectivity, Live
monitoring at 400FPS, Recording at 200 FPS, Simultaneous
recording & Play Back Built in motion sensor, 4 Channel
audio recording, Two Way audio over anetwork, Built in CD-
R/RW, Auto recording with Optimum file size, easy back up
through USB, One monitor and 1 VGA output, Support
multiprotocols with 540GB HDD complete as required.

118,578.00 1 118,578.00
-
3b 16 Channel Real time Digital Vedio Recorder, 16 loop
through vedio output Respectively, TCP/IP Connectivity,
Live monitoring at 400FPS, Recording at 200 FPS,
Simultaneous recording & Play Back Built in motion sensor,
4 Channel audio recording, Two Way audio over anetwork,
Built in CD-R/RW, Auto recording with Optimum file size,
easy back up through USB, One monitor and 1 VGA output,
Support multiprotocols with 540GB HDD complete as Nos. 166,084.00 4 664,336.00
required. -
4 21-INCH Color LCD CCTV MONITOR for viewing No. 32,029.00 5 160,145.00
complete as required
-
Balance work for Intelligent Analogue Addressable Fire Detection & Alarm System

Quantity Amount
S.No. Description Unit Rate Remarks
DSR NON DSR DSR NON DSR
5 PVC insulated copper conductor 1100 volts grade
"FR"Signal wires in existing MS conduits complete as
required -
a) RG 59 coaxial cable Mtrs. 22.00 4235 93,170.00
DSR Items
6 Supply, and fixing of 16 gauge, MS conduits in following
sizes including cost of junction boxes, bends, elbows, sockets,
tees and MS flexible conduit to connect from ceiling to false
ceiling etc. laying in slab, cutting chases and making good or
surface mounted including all fixing hardware.

-
a) 20 mm dia- (DSR-2007 1.20.1 STLCON) RM 77.00 3050 234,850.00
-
TOTAL AMOUNT 234850 1951109
Balance work for Construction of ESIC Medical College and Hospital at Bihta ,Patna(Bihar)

SUMMARY SHEET OF ELECTRICAL

Amount
SUB
DESCRIPTION
HEAD
DSR Non DSR Total

I MV Panels 76714100.00 76714100

II Circuit cum Point Wiring 591515.00 69252197.00 69843712

III LT Cables 12622596.00 68253048.00 80875644

IV Conduit & Wiring for LV System (Tel., Data) 9385573.00 12425429.00 21811002

V Fixing of Fan & Fixtures 1585916.00 1377895.00 2963811

VI Supply of Light Fixtures 21146355.00 21146355

VII Earthing & Lightning Protection System 5605300.00 5842750.00 11448050

VIII Distribution Boards 11621095.00 1587359.00 13208454

IX Optional Capital Items 20243000.00 20243000

X Misc. Items 636600.00 636600

XII HT System 163990.00 33204900.00 33368890

XIII External Lighting 6686275.00 6686275

TOTAL (in Rs.) 41575985.00 317369908.00 358945893.00

Cost Index @ 22% for DSR Items 9146716.7 9146716.7

TOTAL (in Rs.) 50722701.70 317369908.00 368092609.70


Balance work for Construction of ESIC Medical College and Hospital at Bihta ,Patna(Bihar)
Sub-Head-I : Preamble to BOQ for MV Panels
Item Quantity Amount
S.N. Description Unit Rate Remarks
code DSR NON DSR DSR NON DSR
1 2 3 4 5 6 7 8 9 10
Sub-Head-I : MV Panels
Design, Fabrication, Supply, Erection,Testing and commisioning of Powder coated
Main Distribution Panel fabricated out of 14 guage CRCA sheet steel in cubical,
compartmentallised, free standing floor /wall mounted, dust and vermin proof, with
reinforcement of suitable size angle iron, channel, T -iron or flats as required. Cable
gland plates shall be provided on top as well as bottom of the panels. Panels shall
be treated with all anti-corrosive process before painting as per specification.
Panels shall be suitable for 415V, 3-Phase, Four wire, 50 Hz supply complete with
earth bus and lifting hooks as required in case of large panels.Approval shall be
taken for each panel before fabrication. (All hardwares like nuts and bolts used
shall be Galvanized and Zinc passivated)
1 MAIN L.T. Panel (MAIN ESS BLOCK)
A INCOMER FROM TRANSFORMERS(2 Nos. 1500 KVA Each)
Incomer from each transformer shall be provided with the following:
1 nos. 2500 A FP EDO ACB having microprocessor based programmable &
variable trip setting for releases with integral protection for the following:
i) IDMTL Protection for S/C, O/C & E/f releases.
ii) U/V & O/V protection
iii) Anti Pumping device
iv) Trip circuit supervision relay
v) Master trip relay
vi) The ACB shall be complete with 3nos. 2500A/5A, 15VA, 5P10 CTs for protection .
B METERING & INDICATION (for each Incomer)
i) 1 set of phase indicating lamps
ii) 1 set of Voltmeter (0-500V) with VSS with 3 nos. 2A SP MCBs each
1 Nos. Load Analyser cum digital Multifunction Meter with 3 nos. 2500/5A, CL-1
iii)
CTs, as required.
iv) 1 Set of Breaker ON-OFF-TRIP, Spring charged indication Lamps
v) 1 no. of 2500/5A, 15 VA, class-1 CTs for APFC relay
1 No. 400V AC/12V DC, 100VA SMPS (Rectifiers) with TP MCB of suitable rating &
vi)
2nos 6way terminal strip .
C INCOMER FROM GENERATOR (4 nos.- 750 KVA )
Each Incomer from D.G.set shall be provided with the following:
1 nos. 1250 A FP EDO ACB having microprocessor based programmable &
variable trip setting for releases with integral protection for the following:
i) IDMTL Protection for S/C, O/C & E/f releases.
ii) U/V & O/V protection
iii) Anti Pumping device
iv) Trip circuit supervision relay
v) Master trip relay
vi) Reverse power Protection.
vii) The ACB shall be complete with 3nos. 1250A/5A, 15VA, 5P10 CTs for protection.
D METERING & INDICATION (for each Incomer)
i) 1 sets of phase indicating lamps
ii) 1 sets of Voltmeter (0-500V) with VSS each with 3 nos. 2A SP MCBs each
iii) 1 Nos. digital Multifunction Meter with 3 nos. 1250/5A, CL-1 CTs, as required
iv) 1 Sets of Breaker ON-OFF-TRIP, Spring charged indication Lamps
Sub-Head-I : Preamble to BOQ for MV Panels
Item Quantity Amount
S.N. Description Unit Rate Remarks
code DSR NON DSR DSR NON DSR
E BUS COUPLERS
i) 1 nos. 2500A FP EDO ACB
ii) 2 nos. 1250A FP EDO ACB
iii) 3 Set of Breaker ON-OFF-TRIP indication Lamps with each Bus Coupler
F INTERLOCKING.
Incomers from Transformer, Incomers from D.Gs. & Bus couplers shall be
i)
electrically & mechanically interlocked.
G BUS BAR:-
i) 2 Sets of 2500A, TPN Aluminum bus bars with colour coded sleeves.
ii) 2 Sets of 1500A, TPN Aluminum bus bars with colour coded sleeves.
H OUTGOINGS
i) 2 Nos. 1000A TPN ACB
ii) 4 Nos. 500A FP MCCB (50 KA)
iii) 9 Nos. 400A FP MCCB (50 KA)
iv) 7 Nos. 300A FP MCCB (50 KA)
v) 4 Nos. 100A FP MCCB (50 KA)
Supply of LT Panel (ESS-1) as described above Set - 0 0.00
Receiving, fixing, testing & commissioning of LT Panel (ESS-1) as described
Set - 0 0.00
above

2 MAIN L.T. Panel (ESS-2)


A INCOMER FROM TRANSFORMERS(2 Nos. 1500 KVA Each)
Incomer from each transformer shall be provided with the following:
1 nos. 2500 A FP EDO ACB having microprocessor based programmable &
variable trip setting for releases with integral protection for the following:
i) IDMTL Protection for S/C, O/C & E/f releases.
ii) U/V & O/V protection
iii) Anti Pumping device
iv) Trip circuit supervision relay
v) Master trip relay
vi) The ACB shall be complete with 3nos. 2500A/5A, 15VA, 5P10 CTs for protection .
B METERING & INDICATION (for each Incomer)
i) 1 set of phase indicating lamps
ii) 1 set of Voltmeter (0-500V) with VSS with 3 nos. 2A SP MCBs each
1 Nos. Load Analyser cum digital Multifunction Meter with 3 nos. 2500/5A, CL-1
iii)
CTs, as required.
iv) 1 Set of Breaker ON-OFF-TRIP, Spring charged indication Lamps
v) 1 no. of 2500/5A, 15 VA, class-1 CTs for APFC relay
1 No. 400V AC/12V DC, 100VA SMPS (Rectifiers) with TP MCB of suitable rating &
vi)
2nos 6way terminal strip .
C INCOMER FROM GENERATOR (4 nos.- 750 KVA )
Each Incomer from D.G.set shall be provided with the following:
1 nos. 1250 A FP EDO ACB having microprocessor based programmable &
variable trip setting for releases with integral protection for the following:
i) IDMTL Protection for S/C, O/C & E/f releases.
ii) U/V & O/V protection
iii) Anti Pumping device
iv) Trip circuit supervision relay
v) Master trip relay
vi) Reverse power Protection.
Sub-Head-I : Preamble to BOQ for MV Panels
Item Quantity Amount
S.N. Description Unit Rate Remarks
code DSR NON DSR DSR NON DSR
vii) The ACB shall be complete with 3nos.1250A/5A, 15VA, 5P10 CTs for protection.
D METERING & INDICATION (for each Incomer)
i) 1 sets of phase indicating lamps
ii) 1 sets of Voltmeter (0-500V) with VSS each with 3 nos. 2A SP MCBs each
iii) 1 Nos. digital Multifunction Meter with 3 nos. 1250/5A, CL-1 CTs, as required
iv) 1 Sets of Breaker ON-OFF-TRIP, Spring charged indication Lamps
E BUS COUPLERS
i) 1 nos. 2500A FP EDO ACB
ii) 2 nos. 1250A FP EDO ACB
iii) 3 Set of Breaker ON-OFF-TRIP indication Lamps with each Bus Coupler
F INTERLOCKING.
Incomers from Transformer, Incomers from D.Gs. & Bus couplers shall be
i)
electrically & mechanically interlocked.
G BUS BAR:-
i) 2 Sets of 2500A, TPN Aluminum bus bars with colour coded sleeves.
ii) 2 Sets of 1500A, TPN Aluminum bus bars with colour coded sleeves.
H OUTGOINGS
i) 2 Nos. 1000A TPN ACB
ii) 2 Nos. 800A FP MCCB (50 KA)
iii) 4 Nos. 630A FP MCCB (50 KA)
iv) 1 No. 500A FP MCCB (50 KA)
v) 4 Nos. 400A FP MCCB (50 KA)
vi) 6 Nos. 250A FP MCCB (50 KA)
vii) 2 Nos. 200A FP MCCB (50 KA)
viii) 2 Nos. 125A FP MCCB (50 KA)
ix) 2 Nos. 100A FP MCCB (50 KA)
Supply of LT Panel (ESS-2) as described above Set 0.00 0 0.00
Receiving, fixing, testing & commissioning of LT Panel (ESS-2) as described
Set - 0 0.00
above

3 MAIN L.T. Panel (Service Block, ESS-3)


A INCOMER FROM TRANSFORMERS(4 Nos. 1500 KVA Each)
Incomer from each transformer shall be provided with the following:
1 nos. 2500 A FP EDO ACB having microprocessor based programmable &
variable trip setting for releases with integral protection for the following:
i) IDMTL Protection for S/C, O/C & E/f releases.
ii) U/V & O/V protection
iii) Anti Pumping device
iv) Trip circuit supervision relay
v) Master trip relay
vi) The ACB shall be complete with 3nos. 2500A/5A, 15VA, 5P10 CTs for protection .
B METERING & INDICATION (for each Incomer)
i) 1 set of phase indicating lamps
ii) 1 set of Voltmeter (0-500V) with VSS with 3 nos. 2A SP MCBs each
1 Nos. Load Analyser cum digital Multifunction Meter with 3 nos. 2500/5A, CL-1
iii)
CTs, as required.
iv) 1 Set of Breaker ON-OFF-TRIP, Spring charged indication Lamps
v) 1 no. of 2500/5A, 15 VA, class-1 CTs for APFC relay
C INCOMER FROM SYNCHRONISING PANEL (4 nos.)
Sub-Head-I : Preamble to BOQ for MV Panels
Item Quantity Amount
S.N. Description Unit Rate Remarks
code DSR NON DSR DSR NON DSR
Each Incomer from Synchronising panel shall be provided with the following:
1 nos. 2500 A FP EDO ACB having microprocessor based programmable &
variable trip setting for releases with integral protection for the following:
i) IDMTL Protection for S/C, O/C & E/f releases.
ii) U/V & O/V protection
iii) Anti Pumping device
iv) Trip circuit supervision relay
v) Master trip relay
vi) The ACB shall be complete with 3nos. 2500A/5A, 15VA, 5P10 CTs for protection.
D METERING & INDICATION (for each Incomer)
i) 1 sets of phase indicating lamps
ii) 1 sets of Voltmeter (0-500V) with VSS each with 3 nos. 2A SP MCBs each
iii) 1 Nos. digital Multifunction Meter with 3 nos. 2500/5A, CL-1 CTs, as required
iv) 1 Sets of Breaker ON-OFF-TRIP, Spring charged indication Lamps
E BUS COUPLER:-
i) 3 nos. 2500 A FP EDO ACB
ii) 3 Sets of Breaker ON-OFF-TRIP indication Lamps with each Bus Coupler
F INTERLOCKING.
Incomers from Transformer, Incomers from Synch.panel & Bus couplers shall be
i)
electrically & mechanically interlocked.
G BUS BAR:-
i) 4 Sets of 2500A, TPN Aluminum bus bars with colour coded sleeves.
H OUTGOINGS
i) 8 Nos. 1250A FP ACB
ii) 4 Nos. 1250A TP ACB
iii) 2 Nos. 800A FP MCCB (50 KA)
iv) 2 Nos. 630A FP MCCB (50 KA)
v) 10 Nos. 400A FP MCCB (50 KA)
vi) 8 Nos. 250A FP MCCB (50 KA)
vii) 6 No. 200A FP MCCB (50 KA)
viii) 4 No. 100A FP MCCB (50 KA)
Supply of LT Panel (ESS-3) as described above Set 10,485,000.00 1 10485000.00
Receiving, fixing, testing & commissioning of LT Panel (ESS-3) as described
Set 20,000.00 1 20000.00
above

4 MAIN L.T. Panel (ESS-HVAC Plant)


A INCOMER FROM TRANSFORMERS(4 Nos. 1500 KVA Each)
Incomer from each transformer shall be provided with the following:
1 nos. 2500 A FP EDO ACB having microprocessor based programmable &
variable trip setting for releases with integral protection for the following:
i) IDMTL Protection for S/C, O/C & E/f releases.
ii) U/V & O/V protection
iii) Anti Pumping device
iv) Trip circuit supervision relay
v) Master trip relay
vi) The ACB shall be complete with 3nos. 2500A/5A, 15VA, 5P10 CTs for protection .
B METERING & INDICATION (for each Incomer)
i) 1 set of phase indicating lamps
Sub-Head-I : Preamble to BOQ for MV Panels
Item Quantity Amount
S.N. Description Unit Rate Remarks
code DSR NON DSR DSR NON DSR
ii) 1 set of Voltmeter (0-500V) with VSS with 3 nos. 2A SP MCBs each
1 Nos. Load Analyser cum digital Multifunction Meter with 3 nos. 2500/5A, CL-1
iii)
CTs, as required.
iv) 1 Set of Breaker ON-OFF-TRIP, Spring charged indication Lamps
v) 1 no. of 2500/5A, 15 VA, class-1 CTs for APFC relay
C INCOMER FROM SYNCHRONISING PANEL (4 nos.)
Each Incomer from Synchronising panel shall be provided with the following:
1 nos. 2500 A FP EDO ACB having microprocessor based programmable &
variable trip setting for releases with integral protection for the following:
i) IDMTL Protection for S/C, O/C & E/f releases.
ii) U/V & O/V protection
iii) Anti Pumping device
iv) Trip circuit supervision relay
v) Master trip relay
vi) The ACB shall be complete with 3nos. 1250A/5A, 15VA, 5P10 CTs for protection.
D METERING & INDICATION (for each Incomer)
i) 1 sets of phase indicating lamps
ii) 1 sets of Voltmeter (0-500V) with VSS each with 3 nos. 2A SP MCBs each
iii) 1 Nos. digital Multifunction Meter with 3 nos. 2500/5A, CL-1 CTs, as required
iv) 1 Sets of Breaker ON-OFF-TRIP, Spring charged indication Lamps
E BUS COUPLER:-
i) 3 nos. 2500 A FP EDO ACB
ii) 3 Sets of Breaker ON-OFF-TRIP indication Lamps with each Bus Coupler
F INTERLOCKING.
Incomers from Transformer, Incomers from D.Gs. & Bus couplers shall be
i)
electrically & mechanically interlocked.
G BUS BAR:-
i) 4 Sets of 2500A, TPN Aluminum bus bars with colour coded sleeves.
H OUTGOINGS
i) 7 Nos. 1600A TP ACB
ii) 4 Nos. 1250A TP ACB
iii) 9 Nos. 1000A TP ACB
iv) 1 Nos. 630A TPN MCCB (50 KA)
v) 2 Nos. 400A FP MCCB (50 KA)
vi) 4 Nos. 250A TP MCCB (50 KA)
vii) 9 Nos. 160A TP MCCB (50 KA)
viii) 8 Nos. 125A FP MCCB (50 KA)
7 Nos. S/D starter with self illuminated Push button for ON & OFF and suitable
ix)
rating of contactor and O/L relays, suitable for 80 HP Motor.
7 Nos. S/D starter with self illuminated Push button for ON & OFF and suitable
x)
rating of contactor and O/L relays, suitable for 30 HP Motor.
xi) 4 Nos. space for S/D starter with self illuminated Push button for ON & OFF.
Supply of MAIN L.T. Panel (ESS-HVAC) as described above Set 11,870,000.00 1 11870000.00
Receiving, fixing, testing & commissioning of MAIN L.T. Panel (ESS-HVAC) as
Set 25,000.00 1 25000.00
described above

5 AC Aux. Panel - 1 & 2


A INCOMER
i) 2 Nos. 400A TPN MCCB (35 KA)
Sub-Head-I : Preamble to BOQ for MV Panels
Item Quantity Amount
S.N. Description Unit Rate Remarks
code DSR NON DSR DSR NON DSR
B METERING & INDICATION
i) 2 sets of phase indicating lamps
ii) 2 Nos. Voltmeter (0-500V) each with VSS & 3 nos. 2A SP MCB
iii) 2 sets Ammeter (0-400A) each with ASS and 3 nos.100/5A, CT's
C BUS COUPLER:-
i) 1 nos. 400A FP MCCB (35 KA)
D INTERLOCKING.
i) Incomers & Bus couplers shall be electrically & mechanically interlocked.
E BUS-BAR
i) 2 Sets of 400A TPN Aluminium Bus Bar with colour coded PVC Sleeves
D OUTGOINGS
i) 3 Nos. 63A TPN MCCB (35KA)
ii) 24 Nos. 32A TPN MCB (10KA)
iii) 4 No. 32A FP MCB (10KA)
iv) 2 No. 32A DP MCB (10KA)
v) 2 No. 16A TP MCB (10KA)
24 Nos. DOL starter with self illuminated Push button for ON & OFF and suitable
vi)
rating of contactor and O/L relays, suitable for 7.5 HP Motor.
6 Set of Timer (0-3mins.) with Auto manual switch - One each for Time delaying
vii)
among a group of 4 nos. of Starters for Cooling Towers
3 Nos. DOL starter with self illuminated Push button for ON & OFF and suitable
viii)
rating of contactor and O/L relays, suitable for 1.5 HP Motor.
Supply of A.C.Aux. Panel - 1 & 2 as described above Set - 0 0.00
Receiving, fixing, testing & commissioning of A.C.Aux. Panel - 1 & 2 as
Set - 0 0.00
described above

6 Miscleneous Panel ESS-1 (Typical for ESS-2, ESS-3, ESS-HVAC)


A INCOMER
i) 1No. 100A FP Isolator
B METERING & INDICATION
i) 1 set of phase indicating lamps
ii) 1 No. Voltmeter (0-500V) with VSS with 3 nos. 2A SP MCB
iii) 1 set Ammeter (0-100A) with ASS and 3 nos.100/5A, CT's
C BUS-BAR
i) 1 Set of 150A TPN Aluminium Bus Bar with colour coded PVC Sleeves
D OUTGOINGS
i) 3 Nos. 63A FP MCB (10KA)
ii) 2 Nos. 40A FP MCB (10KA)
iii) 1 No. 32A DP MCB (10KA)
Supply of Miscleneous Panel as described above Sets 20,000.00 4 80000.00
Receiving, fixing, testing & commissioning of Miscleneous Panel as
Sets 500.00 4 2000.00
described above

7 Capacitor Panel for ESS-1 (Typical for ESS-2) (400 KVAR)


A INCOMER
i) 1No. 1000A TPN Isolator
B METERING & INDICATION
i) 1 set of phase indicating lamps
ii) 1 No. (0-500V) Voltmeter with VSS with 3 nos. 2A SP MCB
iii) 1 No. 8 steps APFC relay
C BUS-BAR
Sub-Head-I : Preamble to BOQ for MV Panels
Item Quantity Amount
S.N. Description Unit Rate Remarks
code DSR NON DSR DSR NON DSR
i) 1 Set of 1000A TPN Aluminium Bus Bar with colour coded PVC Sleeves
D OUTGOINGS
i) 2 Nos.of 250A TP MCCB (25 KA) with 300A TP contactor (AC-3 duty)
ii) 3 Nos.of 125A TP MCCB (25 KA) with 140A TP contactor (AC-3 duty)
iii) 2 Nos. of 63A TP MCCB (25 KA) with 70A TP contactor (AC-3 duty)
iv) 8 Sets self-Illuminated Red-Green (ON-OFF) push buttons.
2 Nos. 100 KVAR capacitor Bank with 7% detuned harmonic filter & discharge
v)
resistor.
3 Nos. 50 KVAR capacitor Bank with 7% detuned harmonic filter & discharge
vi)
resistor.
2 Nos. 25 KVAR capacitor Bank with 7% detuned harmonic filter & discharge
vii)
resistor.
Supply of Capacitor panel as described above Sets 910,000.00 4 3640000.00
Receiving, fixing, testing & commissioning of Capacitor panel as described
Sets 5,000.00 4 20000.00
above

8 Capacitor Panel for ESS-HVAC (500 KVAR)


A INCOMER
i) 1No. 1250A TPN Isolator
B METERING & INDICATION
i) 1 set of phase indicating lamps
ii) 1 No. (0-500V) Voltmeter with VSS with 3 nos. 2A SP MCB
iii) 1 No. 8 steps APFC relay
C BUS-BAR
i) 1 Set of 1250A TPN Aluminium Bus Bar with colour coded PVC Sleeves
D OUTGOINGS
i) 3 Nos.of 250A TP MCCB (25 KA) with 300A TP contactor (AC-3 duty)
ii) 3 Nos.of 125A TP MCCB (25 KA) with 140A TP contactor (AC-3 duty)
iii) 2 Nos. of 63A TP MCCB (25 KA) with 70A TP contactor (AC-3 duty)
iv) 12 Sets self-Illuminated Red-Green (ON-OFF) push buttons.
3 Nos. 100 KVAR capacitor Bank with 7% detuned harmonic filter & discharge
v)
resistor.
3 Nos. 50 KVAR capacitor Bank with 7% detuned harmonic filter & discharge
vi)
resistor.
2 Nos. 25 KVAR capacitor Bank with 7% detuned harmonic filter & discharge
vii)
resistor.
Supply of Capacitor panel as described above Sets 1060000.00 8 8480000.00
Receiving, fixing, testing & commissioning of Capacitor panel as described
Sets 5000.00 8 40000.00
above

9 FEEDER PILLAR
Design, Fabrication, Supply, Erection, Testing and commisioning of Powder coated,
Weather Proof Double door type Feeder pillar fabricated out of 14 guage CRCA
sheet steel in cubical, free standing, dust and vermin proof, with reinforcement of
suitable size angle iron, channel, T -iron or flats as required. Feeder pillar shall be
treated with all anti-corrosive process before painting as per specification. Feeder
Pillar shall be suitable for 415V, 3-Phase, Four wire, 50 Hz supply complete with
earth bus and lifting hooks as required in case of large panels.Approval shall be
taken for each panel before fabrication. (All hardwares like nuts and bolts used
shall be Galvanized and Zinc passivated )
9.1 FEEDER PILLAR-1
A INCOMER
Sub-Head-I : Preamble to BOQ for MV Panels
Item Quantity Amount
S.N. Description Unit Rate Remarks
code DSR NON DSR DSR NON DSR
i) 1No. 63A FP MCCB(10 KA)
1No. 70A FP Contactor, AOM switch & Astronomical Watch Timers for 24 Hrs.
ii)
setting
B Metering & Indication
1 set of phase indicating lamps
C BUS-BAR
1 Set of 100A TPN Aluminium Bus Bar with colour coded PVC Sleeves
D OUTGOINGS
i) 6 Nos. 20A FP MCB
ii) 12 Nos. 20A DP MCB
Feeder pillars as described above Sets 100000.00 2 200000.00

9.2 FEEDER PILLAR-2


A INCOMER
i) 1No. 63A FP MCCB(10 KA)
1No. 70A FP Contactor, AOM switch & Astronomical Watch Timers for 24 Hrs.
ii)
setting
B Metering & Indication
1 set of phase indicating lamps
C BUS-BAR
1 Set of 100A TPN Aluminium Bus Bar with colour coded PVC Sleeves
D OUTGOINGS
i) 3 Nos. 20A FP MCB
ii) 18 Nos. 20A DP MCB
Feeder pillars as described above Sets 100000.00 2 200000.00

10 Bus Trunking.
SANDWICH TYPE BUS TRUNKING
Design, supply, installation, testing and commisioning of following ratings of powder
coated sheet steel enclosed (IP 42) 415V, 50 Hz., Three phase & neutral
Aluminium conductor Bus Duct suitable for 35 MVA fault rating, including
bends/elbows, transposition piece, expansion joint, Terminal End connector & all
flexible connections as per specifications with all accessories, supports, hardwares
and termination of bus duct to switchgear.

10.1 2500A TPN Aluminium Bus Duct (35 MVA fault rating) in weather proof Enclosure RM 38200.00 456 17419200.00
10.2 Copper flexible End Termination for 2500A TPN No 46800.00 16 748800.00
Notes:
The fabrication of bus duct shall be taken up only after actual measurement and
site routing. Necessary bends, joints and transposition pieces after every 10m or as
i) per local rules whichever is stringent shall be estimated & included in this item.
Payment will be made on running meter basis and no extra shall be paid for the
flexible & transposition pieces.
The supply and fabrication of structural steel support for bus duct support shall be
ii)
paid separately elsewhere in BoQ.

Supply, Design, fabrication, installation, testing & commissioning of a set of 2 nos.


DOL starters for Sump Pumps/Drainage sump pumps in powder coated MS
enclosure complete with 16A TP MCB as incomer, suitable rating of Contactor &
12 Sets 20000.00 2 40000.00
Over load relay suitable for upto 1.5HP Motors including providing of 2 set of Level
controllers. The starter shall start the two motors if the water level increases from
thier pre-determined level.
Sub-Head-I : Preamble to BOQ for MV Panels
Item Quantity Amount
S.N. Description Unit Rate Remarks
code DSR NON DSR DSR NON DSR

Total of MAIN ESS BLOCK

HOSPITAL BLOCK
Sub-Head-I : MV Panels
Design, Fabrication, Supply, Erection,Testing and commisioning of Powder coated
Main Distribution Panel fabricated out of 14 guage CRCA sheet steel in cubical,
compartmentallised, free standing floor /wall mounted, dust and vermin proof, with
reinforcement of suitable size angle iron, channel, T -iron or flats as required. Cable
gland plates shall be provided on top as well as bottom of the panels. Panels shall
be treated with all anti-corrosive process before painting as per specification.
Panels shall be suitable for 415V, 3-Phase, Four wire, 50 Hz supply complete with
earth bus and lifting hooks as required in case of large panels.Approval shall be
taken for each panel before fabrication. (All hardwares like nuts and bolts used
shall be Galvanized and Zinc passivated)

1a Ground Floor Panel-G1 & G2


A INCOMER
2 Nos. 500A FP MCCB (25 KA) with E/f Module & Core Balancing type CT (CBCT)
complete.
B METERING & INDICATION
i) 2 sets. of R,Y,B phase indicating lamps
ii) 2 Sets of Breaker ON-OFF-TRIP indication Lamps.
2 sets of Digital Multifunction meter for Voltage, Current & KW with selector switch.
iii)
Each with 3nos. Of 2A SP MCB & 3nos 400/5A CTs (400A/500V) rating
C BUS COUPLER:-
i) 1 No. 250A FP MCCB with all accessories required.
ii) 1 Set of Breaker ON-OFF-TRIP indication Lamps.
D INTERLOCKING.
Incomer-1, Incomer-2 & Bus coupler shall be electrically & mechanically interlocked.
E BUS BAR:-
2 Sets of 600A, TPN Al.bus bar with colour coded PVC sleeves
F OUTGOINGS
i) 5 Nos. 16A/20A/25A/32A TPN MCB (10KA) as required
ii) 20 Nos. 40A FP MCB (10KA)
iii) 13 Nos. 63A FP MCB (10KA)
iv) 6 Nos.125A FP MCCB (25KA)
Supply of Floor Panel-G1 & G2 as described above Set 0.00 0 0.00
Receiving, fixing, testing & commissioning of Floor Panel as described above Set 0.00 0 0.00

1b Ground Floor Panel-G3 & G4


A INCOMER
2 Nos. 400A FP MCCB (25 KA) with E/f Module & Core Balancing type CT (CBCT)
complete.
B METERING & INDICATION
i) 2 sets. of R,Y,B phase indicating lamps
ii) 2 Sets of Breaker ON-OFF-TRIP indication Lamps.
2 sets of Digital Multifunction meter for Voltage, Current & KW with selector switch.
iii)
Each with 3nos. Of 2A SP MCB & 3nos 400/5A CTs (400A/500V) rating
Sub-Head-I : Preamble to BOQ for MV Panels
Item Quantity Amount
S.N. Description Unit Rate Remarks
code DSR NON DSR DSR NON DSR
C BUS COUPLER:-
i) 1 No. 250A FP MCCB with all accessories required.
ii) 1 Set of Breaker ON-OFF-TRIP indication Lamps.
D INTERLOCKING.
Incomer-1, Incomer-2 & Bus coupler shall be electrically & mechanically interlocked.
E BUS BAR:-
2 Sets of 400A, TPN Al.bus bar with colour coded PVC sleeves
F OUTGOINGS
i) 3 Nos. 16A/20A/25A/32A TPNMCB (10KA) as required
ii) 18 Nos. 40A FP MCB (10KA)
iii) 8 Nos. 63A FP MCB (10KA)
iv) 2 Nos. 63A FP MCCB (25KA)
Supply of Floor Panel-G3 & G4 as described above Set 0.00 0 0.00
Receiving, fixing, testing & commissioning of Floor Panel as described above Set 0.00 0 0.00

1c Ground Floor Panel-G5 & G6


A INCOMER
2 Nos. 300A FP MCCB (25 KA) with E/f Module & Core Balancing type CT (CBCT)
complete.
B METERING & INDICATION
i) 2 sets. of R,Y,B phase indicating lamps
ii) 2 Sets of Breaker ON-OFF-TRIP indication Lamps.
2 sets of Digital Multifunction meter for Voltage, Current & KW with selector switch.
iii)
Each with 3nos. Of 2A SP MCB & 3nos 400/5A CTs (300A/500V) rating
C BUS COUPLER:-
i) 1 No. 160A FP MCCB with all accessories required.
ii) 1 Set of Breaker ON-OFF-TRIP indication Lamps.
D INTERLOCKING.
Incomer-1, Incomer-2 & Bus coupler shall be electrically & mechanically interlocked.
E BUS BAR:-
2 Sets of 300A, TPN Al.bus bar with colour coded PVC sleeves
F OUTGOINGS
i) 3 Nos. 16A/20A/25A/32A TPNMCB (10KA) as required
ii) 9 Nos. 40A FP MCB (10KA)
iii) 8 Nos. 63A FP MCB (10KA)
iv) 3 Nos. 63A FP MCCB (25KA)
Supply of Floor Panel-G5 & G6 as described above Set 0.00 0 0.00
Receiving, fixing, testing & commissioning of Floor Panel as described above Set 0.00 0 0.00

2a First Floor Panel-11 & 12


A INCOMER
2 Nos. 250A FP MCCB (25 KA) with E/f Module & Core Balancing type CT (CBCT)
complete.
B METERING & INDICATION
i) 2 sets. of R,Y,B phase indicating lamps
ii) 2 Sets of Breaker ON-OFF-TRIP indication Lamps.
Sub-Head-I : Preamble to BOQ for MV Panels
Item Quantity Amount
S.N. Description Unit Rate Remarks
code DSR NON DSR DSR NON DSR
2 sets of Digital Multifunction meter for Voltage, Current & KW with selector switch.
iii)
Each with 3nos. Of 2A SP MCB & 3nos 300/5A CTs (300A/500V) rating
C BUS COUPLER:-
i) 1 No. 125.A FP MCCB with all accessories required.
ii) 1 Set of Breaker ON-OFF-TRIP indication Lamps.
D INTERLOCKING.
Incomer-1, Incomer-2 & Bus coupler shall be electrically & mechanically interlocked.
E BUS BAR:-
2 Sets of 300A, TPN Al.bus bar with colour coded PVC sleeves
F OUTGOINGS
i) 4 Nos. 16A/20A/25A/32A TPN MCB (10KA) as required
ii) 13 Nos. 40A FP MCB (10KA)
iii) 7 Nos. 63A FP MCB (10KA)
iv) 3 Nos. 63A FP MCCB (25KA)
Supply of Floor Panel-11 & 12 as described above Set 0.00 0 0.00
Receiving, fixing, testing & commissioning of Floor Panel as described above Set 0.00 0 0.00

2b First Floor Panel-13 & 14


A INCOMER
2 Nos. 400A FP MCCB (25 KA) with E/f Module & Core Balancing type CT (CBCT)
complete.
B METERING & INDICATION
i) 2 sets. of R,Y,B phase indicating lamps
ii) 2 Sets of Breaker ON-OFF-TRIP indication Lamps.
2 sets of Digital Multifunction meter for Voltage, Current & KW with selector switch.
iii)
Each with 3nos. Of 2A SP MCB & 3nos 300/5A CTs (400A/500V) rating
C BUS COUPLER:-
i) 1 No. 250A FP MCCB with all accessories required.
ii) 1 Set of Breaker ON-OFF-TRIP indication Lamps.
D INTERLOCKING.
Incomer-1, Incomer-2 & Bus coupler shall be electrically & mechanically interlocked.
E BUS BAR:-
2 Sets of 400A, TPN Al.bus bar with colour coded PVC sleeves
F OUTGOINGS
i) 3 Nos. 16A/20A/25A/32A TPN MCB (10KA) as required
ii) 16 Nos. 40A FP MCB (10KA)
iii) 11 Nos. 63A FP MCB (10KA)
iv) 3 Nos. 63A FP MCCB (25KA)
Supply of Floor Panel-13 & 14 as described above Set 0.00 0 0.00
Receiving, fixing, testing & commissioning of Floor Panel as described above Set 0.00 0 0.00

2c First Floor Panel-15 & 16


A INCOMER
2 Nos. 200A FP MCCB (25 KA) with E/f Module & Core Balancing type CT (CBCT)
complete.
B METERING & INDICATION
i) 2 sets. of R,Y,B phase indicating lamps
Sub-Head-I : Preamble to BOQ for MV Panels
Item Quantity Amount
S.N. Description Unit Rate Remarks
code DSR NON DSR DSR NON DSR
ii) 2 Sets of Breaker ON-OFF-TRIP indication Lamps.
2 sets of Digital Multifunction meter for Voltage, Current & KW with selector switch.
iii)
Each with 3nos. Of 2A SP MCB & 3nos 400/5A CTs (200A/500V) rating
C BUS COUPLER:-
i) 1 No. 125A FP MCCB with all accessories required.
ii) 1 Set of Breaker ON-OFF-TRIP indication Lamps.
D INTERLOCKING.
Incomer-1, Incomer-2 & Bus coupler shall be electrically & mechanically interlocked.
E BUS BAR:-
2 Sets of 250A, TPN Al.bus bar with colour coded PVC sleeves
F OUTGOINGS
i) 3 Nos. 16A/20A/25A/32A TPNMCB (10KA) as required
ii) 6 Nos. 40A FP MCB (10KA)
iii) 8 Nos. 63A FP MCB (10KA)
iv) 2 Nos. 63A FP MCCB (25KA)
Supply of Floor Panel-15 & 16 as described above Set 0.00 0 0.00
Receiving, fixing, testing & commissioning of Floor Panel as described above Set 0.00 0 0.00

3a Second Floor Panel-21 & 22


A INCOMER
2 Nos. 400A FP MCCB (25 KA) with E/f Module & Core Balancing type CT (CBCT)
complete.
B METERING & INDICATION
i) 2 sets. of R,Y,B phase indicating lamps
ii) 2 Sets of Breaker ON-OFF-TRIP indication Lamps.
2 sets of Digital Multifunction meter for Voltage, Current & KW with selector switch.
iii)
Each with 3nos. Of 2A SP MCB & 3nos 400/5A CTs (400A/500V) rating
C BUS COUPLER:-
i) 1 No. 250A FP MCCB with all accessories required.
ii) 1 Set of Breaker ON-OFF-TRIP indication Lamps .
D INTERLOCKING.
Incomer-1, Incomer-2 & Bus coupler shall be electrically & mechanically interlocked.
E BUS BAR:-
2 Sets of 400A, TPN Al.bus bar with colour coded PVC sleeves
F OUTGOINGS
i) 3 Nos. 16A/20A/25A/32A TPN MCB (10KA) as required
ii) 16 Nos. 40A FP MCB (10KA)
iii) 10 Nos. 63A FP MCB (10KA)
iv) 2 Nos. 63A FP MCCB (25KA)
Supply of Floor Panel-21 & 22 as described above Set 0.00 0 0.00
Receiving, fixing, testing & commissioning of Floor Panel as described above Set 0.00 0 0.00

3b Second Floor Panel-23 & 24


A INCOMER
2 Nos. 300A FP MCCB (25 KA) with E/f Module & Core Balancing type CT (CBCT)
complete.
B METERING & INDICATION
Sub-Head-I : Preamble to BOQ for MV Panels
Item Quantity Amount
S.N. Description Unit Rate Remarks
code DSR NON DSR DSR NON DSR
i) 2 sets. of R,Y,B phase indicating lamps
ii) 2 Sets of Breaker ON-OFF-TRIP indication Lamps.
2 sets of Digital Multifunction meter for Voltage, Current & KW with selector switch.
iii)
Each with 3nos. Of 2A SP MCB & 3nos 300/5A CTs (300A/500V) rating.
C BUS COUPLER:-
i) 1 No. 160A FP MCCB with all accessories required.
ii) 1 Set of Breaker ON-OFF-TRIP indication Lamps .
D INTERLOCKING.
Incomer-1, Incomer-2 & Bus coupler shall be electrically & mechanically interlocked.
E BUS BAR:-
2 Sets of 400A, TPN Al.bus bar with colour coded PVC sleeves
F OUTGOINGS
i) 3 Nos. 16A/20A/25A/32A TPN MCB (10KA) as required
ii) 18 Nos. 40A FP MCB (10KA)
iii) 5 Nos. 63A FP MCB (10KA)
iv) 3 Nos. 63A FP MCCB (25KA)
Supply of Floor Panel-23 & 24 as described above Set 0.00 0 0.00
Receiving, fixing, testing & commissioning of Floor Panel as described above Set 0.00 0 0.00

3c Second Floor Panel-25 & 26


A INCOMER
2 Nos. 250A FP MCCB (25 KA) with E/f Module & Core Balancing type CT (CBCT)
complete.
B METERING & INDICATION
i) 2 sets. of R,Y,B phase indicating lamps
ii) 2 Sets of Breaker ON-OFF-TRIP indication Lamps.
2 sets of Digital Multifunction meter for Voltage, Current & KW with selector switch.
iii)
Each with 3nos. Of 2A SP MCB & 3nos 250/5A CTs (250A/500V) rating
C BUS COUPLER:-
i) 1 No. 125A FP MCCB with all accessories required.
ii) 1 Set of Breaker ON-OFF-TRIP indication Lamps.
D INTERLOCKING.
Incomer-1, Incomer-2 & Bus coupler shall be electrically & mechanically interlocked.
E BUS BAR:-
2 Sets of 250A, TPN Al.bus bar with colour coded PVC sleeves
F OUTGOINGS
i) 2 Nos. 16A/20A/25A/32A TPNMCB (10KA) as required
ii) 7 Nos. 40A FP MCB (10KA)
iii) 7 Nos. 63A FP MCB (10KA)
iv) 2 Nos. 63A FP MCCB (25KA)
Supply of Floor Panel-25 & 26 as described above Set 192100.00 6 1152600.00
Receiving, fixing, testing & commissioning of Floor Panel as described above Set 4000.00 6 24000.00

4a Third Floor Panel-31 & 32


A INCOMER
2 Nos. 400A FP MCCB (25 KA) with E/f Module & Core Balancing type CT (CBCT)
complete.
Sub-Head-I : Preamble to BOQ for MV Panels
Item Quantity Amount
S.N. Description Unit Rate Remarks
code DSR NON DSR DSR NON DSR
B METERING & INDICATION
i) 2 sets. of R,Y,B phase indicating lamps.
ii) 2 Sets of Breaker ON-OFF-TRIP indication Lamps.
2 sets of Digital Multifunction meter for Voltage, Current & KW with selector switch.
iii)
Each with 3nos. Of 2A SP MCB & 3nos 400/5A CTs (400A/500V) rating.
C BUS COUPLER:-
i) 1 No. 250A FP MCCB with all accessories required.
ii) 1 Set of Breaker ON-OFF-TRIP indication Lamps.
D INTERLOCKING.
Incomer-1, Incomer-2 & Bus coupler shall be electrically & mechanically interlocked.
E BUS BAR:-
2 Sets of 400A, TPN Al.bus bar with colour coded PVC sleeves
F OUTGOINGS
i) 4 Nos. 16A/20A/25A/32A TPN MCB (10KA) as required.
ii) 10 Nos. 40A FP MCB (10KA)
iii) 14 Nos. 63A FP MCB (10KA)
iv) 2 Nos. 63A FP MCCB (25KA)
Supply of Floor Panel-31& 32 as described above Set 0.00 0 0.00
Receiving, fixing, testing & commissioning of Floor Panel as described above Set 0.00 0 0.00

4b Third Floor Panel-33 & 34


A INCOMER
2 Nos. 400A FP MCCB (25 KA) with E/f Module & Core Balancing type CT (CBCT)
complete.
B METERING & INDICATION
i) 2 sets. of R,Y,B phase indicating lamps
ii) 2 Sets of Breaker ON-OFF-TRIP indication Lamps.
2 sets of Digital Multifunction meter for Voltage, Current & KW with selector switch.
iii)
Each with 3nos. Of 2A SP MCB & 3nos 400/5A CTs (400A/500V) rating.
C BUS COUPLER:-
i) 1 No. 250A FP MCCB with all accessories required.
ii) 1 Set of Breaker ON-OFF-TRIP indication Lamps.
D INTERLOCKING.
Incomer-1, Incomer-2 & Bus coupler shall be electrically & mechanically interlocked.
E BUS BAR:-
2 Sets of 400A, TPN Al.bus bar with colour coded PVC sleeves.
F OUTGOINGS
i) 2 Nos. 16A/20A/25A/32A TPN MCB (10KA)
ii) 15 Nos. 40A FP MCB (10KA)
iii) 11 Nos. 63A FP MCB (10KA)
iv) 3 Nos. 63A FP MCCB (25KA)
Supply of Floor Panel-33 & 34as described above Set 0.00 0 0.00
Receiving, fixing, testing & commissioning of Floor Panel as described above Set 0.00 0 0.00

4c Third Floor Panel-35 & 36


A INCOMER
Sub-Head-I : Preamble to BOQ for MV Panels
Item Quantity Amount
S.N. Description Unit Rate Remarks
code DSR NON DSR DSR NON DSR
2 Nos. 250A FP MCCB (25 KA) with E/f Module & Core Balancing type CT (CBCT)
complete.
B METERING & INDICATION
i) 2 sets. of R,Y,B phase indicating lamps
ii) 2 Sets of Breaker ON-OFF-TRIP indication Lamps.
2 sets of Digital Multifunction meter for Voltage, Current & KW with selector switch.
iii)
Each with 3nos. Of 2A SP MCB & 3nos 250/5A CTs (250A/500V) rating
C BUS COUPLER:-
i) 1 No. 125A FP MCCB with all accessories required.
ii) 1 Set of Breaker ON-OFF-TRIP indication Lamps.
D INTERLOCKING.
Incomer-1, Incomer-2 & Bus coupler shall be electrically & mechanically interlocked.
E BUS BAR:-
2 Sets of 300A, TPN Al.bus bar with colour coded PVC sleeves
F OUTGOINGS
i) 2 Nos. 16A/20A/25A/32A TPNMCB (10KA) as required
ii) 10 Nos. 40A FP MCB (10KA)
iii) 6 Nos. 63A FP MCB (10KA)
iv) 2 Nos. 63A FP MCCB (25KA)
Supply of Floor Panel-35 & 36 as described above Set 197300.00 8 1578400.00
Receiving, fixing, testing & commissioning of Floor Panel as described above Set 4000.00 8 32000.00

5a Fourth Floor Panel-41 & 42


A INCOMER
2 Nos. 400A FP MCCB (25 KA) with E/f Module & Core Balancing type CT (CBCT)
complete.
B METERING & INDICATION
i) 2 sets. of R,Y,B phase indicating lamps
ii) 2 Sets of Breaker ON-OFF-TRIP indication Lamps.
2 sets of Digital Multifunction meter for Voltage, Current & KW with selector switch.
iii)
Each with 3nos. Of 2A SP MCB & 3nos 250/5A CTs (250A/500V) rating
C BUS COUPLER:-
i) 1 No. 250A FP MCCB with all accessories required.
ii) 1 Set of Breaker ON-OFF-TRIP indication Lamps.
D INTERLOCKING.
Incomer-1, Incomer-2 & Bus coupler shall be electrically & mechanically interlocked.
E BUS BAR:-
2 Sets of 400A, TPN Al.bus bar with colour coded PVC sleeves
F OUTGOINGS
i) 3 Nos. 16A/20A/25A/32A TPN MCB (10KA) as required
ii) 10 Nos. 40A FP MCB (10KA)
iii) 14 Nos. 63A FP MCB (10KA)
iv) 3 Nos. 63A FP MCCB (25KA)
Supply of Floor Panel-41 & 42 as described above Set 0.00 0 0.00
Receiving, fixing, testing & commissioning of Floor Panel as described above Set 0.00 0 0.00

5b Fourth Floor Panel-43 & 44


Sub-Head-I : Preamble to BOQ for MV Panels
Item Quantity Amount
S.N. Description Unit Rate Remarks
code DSR NON DSR DSR NON DSR
A INCOMER
2 Nos. 400A FP MCCB (25 KA) with E/f Module & Core Balancing type CT (CBCT)
complete.
B METERING & INDICATION
i) 2 sets. of R,Y,B phase indicating lamps
ii) 2 Sets of Breaker ON-OFF-TRIP indication Lamps.
2 sets of Digital Multifunction meter for Voltage, Current & KW with selector switch.
iii)
Each with 3nos. Of 2A SP MCB & 3nos 300/5A CTs (300A/500V) rating
C BUS COUPLER:-
i) 1 No. 250A FP MCCB with all accessories required.
ii) 1 Set of Breaker ON-OFF-TRIP indication Lamps.
D INTERLOCKING.
Incomer-1, Incomer-2 & Bus coupler shall be electrically & mechanically interlocked.
E BUS BAR:-
2 Sets of 400A, TPN Al.bus bar with colour coded PVC sleeves
F OUTGOINGS
i) 3 Nos. 16A/20A/25A/32A TPN MCB (10KA) as required
ii) 13 Nos. 40A FP MCB (10KA)
iii) 10 Nos. 63A FP MCB (10KA)
iv) 3 Nos. 63A FP MCCB (25KA)
Supply of Floor Panel-43 & 44 as described above Set 0.00 0 0.00
Receiving, fixing, testing & commissioning of Floor Panel as described above Set 0.00 0 0.00

5c Fourth Floor Panel-45 & 46


A INCOMER
2 Nos. 250A FP MCCB (25 KA) with E/f Module & Core Balancing type CT (CBCT)
complete.
B METERING & INDICATION
i) 2 sets. of R,Y,B phase indicating lamps
ii) 2 Sets of Breaker ON-OFF-TRIP indication Lamps.
2 sets of Digital Multifunction meter for Voltage, Current & KW with selector switch.
iii)
Each with 3nos. Of 2A SP MCB & 3nos 400/5A CTs (250A/500V) rating
C BUS COUPLER:-
i) 1 No. 125A FP MCCB with all accessories required.
ii) 1 Set of Breaker ON-OFF-TRIP indication Lamps.
D INTERLOCKING.
Incomer-1, Incomer-2 & Bus coupler shall be electrically & mechanically interlocked.
E BUS BAR:-
2 Sets of 300A, TPN Al.bus bar with colour coded PVC sleeves
F OUTGOINGS
i) 2 Nos. 16A/20A/25A/32A TPNMCB (10KA) as required
ii) 11 Nos. 40A FP MCB (10KA)
iii) 6 Nos. 63A FP MCB (10KA)
iv) 2 Nos. 63A FP MCCB (25KA)
Supply of Floor Panel-45 & 46 as described above Set 0.00 0 0.00
Receiving, fixing, testing & commissioning of Floor Panel as described above Set 0.00 0 0.00
Sub-Head-I : Preamble to BOQ for MV Panels
Item Quantity Amount
S.N. Description Unit Rate Remarks
code DSR NON DSR DSR NON DSR
6a Fifth Floor Panel-51 & 52
A INCOMER
2 Nos. 400A FP MCCB (25 KA) with E/f Module & Core Balancing type CT (CBCT)
complete.
B METERING & INDICATION
i) 2 sets. of R,Y,B phase indicating lamps
ii) 2 Sets of Breaker ON-OFF-TRIP indication Lamps.
2 sets of Digital Multifunction meter for Voltage, Current & KW with selector switch.
iii)
Each with 3nos. Of 2A SP MCB & 3nos 400/5A CTs (400A/500V) rating
C BUS COUPLER:-
i) 1 No. 250A FP MCCB with all accessories required.
ii) 1 Set of Breaker ON-OFF-TRIP indication Lamps .
D INTERLOCKING.
Incomer-1, Incomer-2 & Bus coupler shall be electrically & mechanically interlocked.
E BUS BAR:-
2 Sets of 400A, TPN Al.bus bar with colour coded PVC sleeves
F OUTGOINGS
i) 4 Nos. 16A/20A/25A/32A TPN MCB (10KA) as required
ii) 10 Nos. 40A FP MCB (10KA)
iii) 14 Nos. 63A FP MCB (10KA)
iv) 3 Nos. 63A FP MCCB (25KA)
Supply of Floor Panel-51 & 52 as described above Set 0.00 0 0.00
Receiving, fixing, testing & commissioning of Floor Panel as described above Set 0.00 0 0.00

6b Fifth Floor Panel-53 & 54


A INCOMER
2 Nos. 400A FP MCCB (25 KA) with E/f Module & Core Balancing type CT (CBCT)
complete.
B METERING & INDICATION
i) 2 sets. of R,Y,B phase indicating lamps
ii) 2 Sets of Breaker ON-OFF-TRIP indication Lamps.
2 sets of Digital Multifunction meter for Voltage, Current & KW with selector switch.
iii)
Each with 3nos. Of 2A SP MCB & 3nos 300/5A CTs (300A/500V) rating
C BUS COUPLER:-
i) 1 No. 250A FP MCCB with all accessories required.
ii) 1 Set of Breaker ON-OFF-TRIP indication Lamps.
D INTERLOCKING.
Incomer-1, Incomer-2 & Bus coupler shall be electrically & mechanically interlocked.
E BUS BAR:-
2 Sets of 400A, TPN Al.bus bar with colour coded PVC sleeves
F OUTGOINGS
i) 4 Nos. 16A/20A/25A/32A TPN MCB (10KA)
ii) 17 Nos. 40A FP MCB (10KA)
iii) 10 Nos. 63A FP MCB (10KA)
iv) 3 Nos. 63A FP MCCB (25KA)
Supply of Floor Panel-53 & 54 as described above Set 0.00 0 0.00
Receiving, fixing, testing & commissioning of Floor Panel as described above Set 0.00 0 0.00
Sub-Head-I : Preamble to BOQ for MV Panels
Item Quantity Amount
S.N. Description Unit Rate Remarks
code DSR NON DSR DSR NON DSR

6c Fifth Floor Panel-55 & 56


A INCOMER
2 Nos. 200A FP MCCB (25 KA) with E/f Module & Core Balancing type CT (CBCT)
complete.
B METERING & INDICATION
i) 2 sets. of R,Y,B phase indicating lamps
ii) 2 Sets of Breaker ON-OFF-TRIP indication Lamps.
2 sets of Digital Multifunction meter for Voltage, Current & KW with selector switch.
iii)
Each with 3nos. Of 2A SP MCB & 3nos 200/5A CTs (200A/500V) rating
C BUS COUPLER:-
i) 1 No. 100A FP MCCB with all accessories required.
ii) 1 Set of Breaker ON-OFF-TRIP indication Lamps.
D INTERLOCKING.
Incomer-1, Incomer-2 & Bus coupler shall be electrically & mechanically interlocked.
E BUS BAR:-
2 Sets of 200A, TPN Al.bus bar with colour coded PVC sleeves
F OUTGOINGS
i) 2 Nos. 16A/20A/25A/32A TPNMCB (10KA) as required
ii) 9 Nos. 40A FP MCB (10KA)
iii) 7 Nos. 63A FP MCB (10KA)
iv) 2 Nos. 63A FP MCCB (25KA)
Supply of Floor Panel-55 & 56 as described above Set 0.00 0 0.00
Receiving, fixing, testing & commissioning of Floor Panel as described above Set 0.00 0 0.00

7a Sixth Floor Panel-61 & 62


A INCOMER
2 Nos. 400A FP MCCB (25 KA) with E/f Module & Core Balancing type CT (CBCT)
complete.
B METERING & INDICATION
i) 2 sets. of R,Y,B phase indicating lamps
ii) 2 Sets of Breaker ON-OFF-TRIP indication Lamps.
2 sets of Digital Multifunction meter for Voltage, Current & KW with selector switch.
iii)
Each with 3nos. Of 2A SP MCB & 3nos 250/5A CTs (250A/500V) rating
C BUS COUPLER:-
i) 1 No. 250A FP MCCB with all accessories required.
ii) 1 Set of Breaker ON-OFF-TRIP indication Lamps.
D INTERLOCKING.
Incomer-1, Incomer-2 & Bus coupler shall be electrically & mechanically interlocked.
E BUS BAR:-
2 Sets of 400A, TPN Al.bus bar with colour coded PVC sleeves
F OUTGOINGS
i) 10 Nos. 63A FP MCB (10KA)
ii) 14 Nos. 40A FP MCB (10KA)
iii) 3 Nos. 63A FP MCCB (25KA)
Supply of Floor Panel-61 & 62 as described above Set 0.00 0 0.00
Receiving, fixing, testing & commissioning of Floor Panel as described above Set 0.00 0 0.00
Sub-Head-I : Preamble to BOQ for MV Panels
Item Quantity Amount
S.N. Description Unit Rate Remarks
code DSR NON DSR DSR NON DSR

7b Sixth Floor Panel-63 & 64


A INCOMER
2 Nos. 400A FP MCCB (25 KA) with E/f Module & Core Balancing type CT (CBCT)
complete.
B METERING & INDICATION
i) 2 sets. of R,Y,B phase indicating lamps
ii) 2 Sets of Breaker ON-OFF-TRIP indication Lamps.
2 sets of Digital Multifunction meter for Voltage, Current & KW with selector switch.
iii)
Each with 3nos. Of 2A SP MCB & 3nos 300/5A CTs (400A/500V) rating
C BUS COUPLER:-
i) 1 No. 250A FP MCCB with all accessories required.
ii) 1 Set of Breaker ON-OFF-TRIP indication Lamps.
D INTERLOCKING.
Incomer-1, Incomer-2 & Bus coupler shall be electrically & mechanically interlocked.
E BUS BAR:-
2 Sets of 400A, TPN Al.bus bar with colour coded PVC sleeves
F OUTGOINGS
i) 9 Nos. 63A FP MCB (10KA)
ii) 20 Nos. 40A FP MCB (10KA)
iii) 4 Nos. 63A FP MCCB (25KA)
Supply of Floor Panel-63 & 64 as described above Set 0.00 0 0.00
Receiving, fixing, testing & commissioning of Floor Panel as described above Set 0.00 0 0.00

7c Sixth Floor Panel-65 & 66


A INCOMER
2 Nos. 200A FP MCCB (25 KA) with E/f Module & Core Balancing type CT (CBCT)
complete.
B METERING & INDICATION
i) 2 sets. of R,Y,B phase indicating lamps
ii) 2 Sets of Breaker ON-OFF-TRIP indication Lamps.
2 sets of Digital Multifunction meter for Voltage, Current & KW with selector switch.
iii)
Each with 3nos. Of 2A SP MCB & 3nos 200/5A CTs (200A/500V) rating
C BUS COUPLER:-
i) 1 No. 100A FP MCCB with all accessories required.
ii) 1 Set of Breaker ON-OFF-TRIP indication Lamps.
D INTERLOCKING.
Incomer-1, Incomer-2 & Bus coupler shall be electrically & mechanically interlocked.
E BUS BAR:-
2 Sets of 200A, TPN Al.bus bar with colour coded PVC sleeves
F OUTGOINGS
i) 2 Nos. 16A/20A/25A/32A TPNMCB (10KA) as required
ii) 9 Nos. 40A FP MCB (10KA)
iii) 5 Nos. 63A FP MCB (10KA)
iv) 2 Nos. 63A FP MCCB (25KA)
Supply of Floor Panel-65 & 66 as described above Set 174300.00 8 1394400.00
Receiving, fixing, testing & commissioning of Floor Panel as described above Set 4000.00 8 32000.00
Sub-Head-I : Preamble to BOQ for MV Panels
Item Quantity Amount
S.N. Description Unit Rate Remarks
code DSR NON DSR DSR NON DSR

8a Seventh Floor Panel-71 & 72


A INCOMER
2 Nos. 400A FP MCCB (25 KA) with E/f Module & Core Balancing type CT (CBCT)
complete.
B METERING & INDICATION
i) 2 sets. of R,Y,B phase indicating lamps
ii) 2 Sets of Breaker ON-OFF-TRIP indication Lamps.
2 sets of Digital Multifunction meter for Voltage, Current & KW with selector switch.
iii)
Each with 3nos. Of 2A SP MCB & 3nos 250/5A CTs (250A/500V) rating
C BUS COUPLER:-
i) 1 No. 250A FP MCCB with all accessories required.
ii) 1 Set of Breaker ON-OFF-TRIP indication Lamps.
D INTERLOCKING.
Incomer-1, Incomer-2 & Bus coupler shall be electrically & mechanically interlocked.
E BUS BAR:-
2 Sets of 400A, TPN Al.bus bar with colour coded PVC sleeves
F OUTGOINGS
i) 10 Nos. 63A FP MCB (10KA)
ii) 14 Nos. 40A FP MCB (10KA)
iii) 3 Nos. 63A FP MCCB (25KA)
Supply of Floor Panel-71 & 72 as described above Set 0.00 0 0.00
Receiving, fixing, testing & commissioning of Floor Panel as described above Set 0.00 0 0.00

8b Seventh Floor Panel-73 & 74


2 Nos. 500A FP MCCB (25 KA) with E/f Module & Core Balancing type CT (CBCT)
complete.
B METERING & INDICATION
i) 2 sets. of R,Y,B phase indicating lamps
ii) 2 Sets of Breaker ON-OFF-TRIP indication Lamps.
2 sets of Digital Multifunction meter for Voltage, Current & KW with selector switch.
iii)
Each with 3nos. Of 2A SP MCB & 3nos 250/5A CTs (500A/500V) rating
C BUS COUPLER:-
i) 1 No. 300A FP MCCB with all accessories required.
ii) 1 Set of Breaker ON-OFF-TRIP indication Lamps.
D INTERLOCKING.
Incomer-1, Incomer-2 & Bus coupler shall be electrically & mechanically interlocked.
E BUS BAR:-
2 Sets of 500A, TPN Al.bus bar with colour coded PVC sleeves
F OUTGOINGS
i) 12 Nos. 63A FP MCB (10KA)
ii) 21 Nos. 40A FP MCB (10KA)
iii) 3 Nos. 63A FP MCCB (25KA)
Supply of Floor Panel-73 & 74 as described above Set 0.00 0 0.00
Receiving, fixing, testing & commissioning of Floor Panel as described above Set 0.00 0 0.00

8c Seventh Floor Panel-75 & 76


Sub-Head-I : Preamble to BOQ for MV Panels
Item Quantity Amount
S.N. Description Unit Rate Remarks
code DSR NON DSR DSR NON DSR
A INCOMER
2 Nos. 200A FP MCCB (25 KA) with E/f Module & Core Balancing type CT (CBCT)
complete.
B METERING & INDICATION
i) 2 sets. of R,Y,B phase indicating lamps
ii) 2 Sets of Breaker ON-OFF-TRIP indication Lamps.
2 sets of Digital Multifunction meter for Voltage, Current & KW with selector switch.
iii)
Each with 3nos. Of 2A SP MCB & 3nos 200/5A CTs (200A/500V) rating
C BUS COUPLER:-
i) 1 No. 100A FP MCCB with all accessories required.
ii) 1 Set of Breaker ON-OFF-TRIP indication Lamps.
D INTERLOCKING.
Incomer-1, Incomer-2 & Bus coupler shall be electrically & mechanically interlocked.
E BUS BAR:-
2 Sets of 200A, TPN Al.bus bar with colour coded PVC sleeves
F OUTGOINGS
i) 2 Nos. 16A/20A/25A/32A TPNMCB (10KA) as required
ii) 7 Nos. 40A FP MCB (10KA)
iii) 7 Nos. 63A FP MCB (10KA)
iv) 2 Nos. 63A FP MCCB (25KA)
Supply of Floor Panel-75 & 76 as described above Set 0.00 0 0.00
Receiving, fixing, testing & commissioning of Floor Panel as described above Set 0.00 0 0.00

9 Basement Floor Panel


A INCOMER
1 nos. 400 A 4 pole MCCB (35KA) with E/f Module & Core Balancing type CT
(CBCT) complete.
B METERING & INDICATION
i) 1 setof R,Y,B phase indicating lamps
ii) 1 Set of Breaker ON-OFF-TRIP indication Lamps.
1 set of Digital Multifunction meter for Voltage, Current & KW with selector switch.
iii)
Each with 3nos. Of 2A SP MCB & 3nos 400/5A CTs (400A/500V) rating
C BUS BAR:-
1 Set of 400A, TPN Al.bus bar with colour coded PVC sleeves
D OUTGOINGS
i) 8 Nos. 40A FP MCB (10KA)
ii) 10 Nos. 63A FP MCB (10KA)
iii) 1 No. 30A TPN MCCB (35KA)
iv) 3 Nos. 40A TPN MCCB (35KA)
v) 2 Nos. 63A TPN MCCB (35KA)
vi) 1 No. 80A FP MCCB (35KA)
vii) 1 No.100A FP MCCB (35KA)
Supply of Basement Panel-1 as described above Set 0.00 0 0.00
Receiving, fixing, testing & commissioning of Basement Panel-1 as described
Set 0.00 0 0.00
above

10 Ventilation & Press.Panel-1 (Loc.-Basement)


A INCOMER
Sub-Head-I : Preamble to BOQ for MV Panels
Item Quantity Amount
S.N. Description Unit Rate Remarks
code DSR NON DSR DSR NON DSR
1 nos. 250 A 4 pole MCCB (25KA) with E/f Module & Core Balancing type CT
(CBCT) complete.
B METERING & INDICATION
i) 1 setof R,Y,B phase indicating lamps
ii) 1 Set of Breaker ON-OFF-TRIP indication Lamps.
1 set of Digital Multifunction meter for Voltage, Current & KW with selector switch.
iii)
Each with 3nos. Of 2A SP MCB & 3nos 250/5A CTs (250A/500V) rating
C BUS BAR:-
1 Set of 300A, TPN Al.bus bar with colour coded PVC sleeves
D OUTGOINGS
i) 2 Nos. 20A TPN MCB (10KA)
ii) 2 Nos. 20A TP MCB (10KA)
iii) 5 Nos. 30A TP MCCB (25KA)
iv) 2 Nos. 40A TP MCCB (25KA)
v) 4 Nos. 63A TP MCCB (25KA)
3 sets of S/D starter each with self illuminated Push button for ON & OFF and
vi)
suitable rating of contactor and O/L relays, suitable for 25 HP Motor.
1 set of S/D starter each with self illuminated Push button for ON & OFF and
vii)
suitable rating of contactor and O/L relays, suitable for 15 HP Motor.
4 sets of DOL starter each with self illuminated Push button for ON & OFF and
viii)
suitable rating of contactor and O/L relays, suitable for 7.5 HP Motor.
1 set of DOL starter each with self illuminated Push button for ON & OFF and
ix)
suitable rating of contactor and O/L relays, suitable for 5 HP Motor.
1 set of DOL starter each with self illuminated Push button for ON & OFF and
x)
suitable rating of contactor and O/L relays, suitable for 3 HP Motor.
Supply of Vent.& Press.Panel-1 as described above Set 0.00 0 0.00
Receiving, fixing, testing & commissioning of Vent.& Press. Panel-1 as
Set 0.00 0 0.00
described above

11 Ventilation & Press. Panel-2 (Loc.-Basement)


A INCOMER
1 nos. 250 A 4 pole MCCB (25KA) with E/f Module & Core Balancing type CT
(CBCT) complete.
B METERING & INDICATION
i) 1 setof R,Y,B phase indicating lamps
ii) 1 Set of Breaker ON-OFF-TRIP indication Lamps.
1 set of Digital Multifunction meter for Voltage, Current & KW with selector switch.
iii)
Each with 3nos. Of 2A SP MCB & 3nos 250/5A CTs (250A/500V) rating
C BUS BAR:-
1 Set of 300A, TPN Al.bus bar with colour coded PVC sleeves
D OUTGOINGS
i) 1 No. 20A TPN MCB (10KA)
ii) 2 Nos. 20A TP MCB (10KA)
iii) 5 Nos. 30A TP MCCB (25KA)
iv) 2 Nos. 40A TP MCCB (25KA)
v) 2 Nos. 63A TP MCCB (25KA)
vi) 1 No.125A FP MCCB (25KA)
1 set of S/D starter each with self illuminated Push button for ON & OFF and
vii)
suitable rating of contactor and O/L relays, suitable for 25 HP Motor.
1 set of S/D starter each with self illuminated Push button for ON & OFF and
viii)
suitable rating of contactor and O/L relays, suitable for 15 HP Motor.
Sub-Head-I : Preamble to BOQ for MV Panels
Item Quantity Amount
S.N. Description Unit Rate Remarks
code DSR NON DSR DSR NON DSR
4 sets of DOL starter each with self illuminated Push button for ON & OFF and
ix)
suitable rating of contactor and O/L relays, suitable for 7.5 HP Motor.
1 set of DOL starter each with self illuminated Push button for ON & OFF and
x)
suitable rating of contactor and O/L relays, suitable for 5 HP Motor.
Supply of Vent.& Press.Panel-2 as described above Set 0.00 0 0.00
Receiving, fixing, testing & commissioning of Vent.& Press. Panel-2 as
Set 0.00 0 0.00
described above

12 Ventilation & Press. Panel-3 (Loc.-Basement)


A INCOMER
1 No.125A FP MCCB (16KA)
B METERING & INDICATION
i) 1 setof R,Y,B phase indicating lamps
ii) 1 Set of Breaker ON-OFF-TRIP indication Lamps.
1 set of Digital Multifunction meter for Voltage, Current & KW with selector switch.
iii)
Each with 3nos. Of 2A SP MCB & 3nos 125/5A CTs (125A/500V) rating
C BUS BAR:-
1 Set of 150A, TPN Al.bus bar with colour coded PVC sleeves
D OUTGOINGS
i) 2 Nos. 20A TPN MCB (10KA)
ii) 2 Nos. 20A TP MCB (10KA)
iii) 9 Nos. 32A TP MCB (10KA)
6 sets of DOL starter each with self illuminated Push button for ON & OFF and
iv)
suitable rating of contactor and O/L relays, suitable for 7.5 HP Motor.
1 set of DOL starter each with self illuminated Push button for ON & OFF and
v)
suitable rating of contactor and O/L relays, suitable for 5 HP Motor.
1 set of DOL starter each with self illuminated Push button for ON & OFF and
vi)
suitable rating of contactor and O/L relays, suitable for 3 HP Motor.
vii) Supply of Vent.& Press.Panel-3 as described above Set 0.00 0 0.00
Receiving, fixing, testing & commissioning of Vent.& Press. Panel-3 as
viii) Set 0.00 0 0.00
described above

13 MDB-UPS-1 & MDB-UPS-2 (Loc.-Basement)


A INCOMER
2 nos. 1000A 4 pole MCCB (35KA) with over-rated neutral.
B METERING & INDICATION
i) 2 sets. of R,Y,B phase indicating lamps
ii) 2 Sets of Breaker ON-OFF-TRIP indication Lamps.
2 sets of Digital Multifunction meter for Voltage, Current & KW with selector switch.
iii)
Each with 3nos. Of 2A SP MCB & 3nos 800/5A CTs (800A/500V) rating
C BUS COUPLER:-
i) 1 No. 630A FP MCCB (35KA) with over-rated neutral.
ii) 1 Set of Breaker ON-OFF-TRIP indication Lamps .
D INTERLOCKING.
Incomer-1, Incomer-2 & Bus coupler shall be electrically & mechanically interlocked.
E BUS BAR:-
2 Set of 1000A, FP Al.bus bar with colour coded PVC sleeves
F OUTGOINGS
i) 6 Nos. 63A FP MCCB (35KA) with over-rated neutral.
ii) 10 Nos. 100A FP MCCB (35KA) with over-rated neutral.
iii) 4 Nos. 125A FP MCCB (35KA) with over-rated neutral.
Sub-Head-I : Preamble to BOQ for MV Panels
Item Quantity Amount
S.N. Description Unit Rate Remarks
code DSR NON DSR DSR NON DSR
iv) 2 Nos. 160A FP MCCB (35KA) with over-rated neutral.
v) 4 Nos. 200A FP MCCB (35KA) with over-rated neutral.
Supply of MDB-UPS-1 & MDB UPS-2 as described above Set 0.00 0 0.00
Receiving, fixing, testing & commissioning of MDB-UPS-1 & MDB UPS-2 as
Set 0.00 0 0.00
described above

14 UPS Panel- GD1 & GD2 (typ.for 2A1 & 2A2; 3A1 & 3A2)
A INCOMER
2 nos.100A 4 pole MCCB (25KA) with over-rated neutral.
B METERING & INDICATION
i) 2 sets. of R,Y,B phase indicating lamps
ii) 2 Sets of Breaker ON-OFF-TRIP indication Lamps.
2 sets of Digital Multifunction meter for Voltage, Current & KW with selector switch.
iii)
Each with 3nos. Of 2A SP MCB & 3nos 100/5A CTs (100A/500V) rating
C BUS COUPLER:-
i) 1 No. 63A FP MCCB (25KA) with over-rated neutral.
ii) 1 Set of Breaker ON-OFF-TRIP indication Lamps .
D INTERLOCKING.
Incomer-1, Incomer-2 & Bus coupler shall be electrically & mechanically interlocked.
E BUS BAR:-
2 Set of 100A, FP Al.bus bar with colour coded PVC sleeves
F OUTGOINGS
i) 4 Nos. 40A FP MCB (10KA)
ii) 4 Nos. 63A FP MCB (10KA)
Supply of UPS Panel-GD1 & GD2 as described above Sets 0.00 0 0.00
Receiving, fixing, testing & commissioning of UPS Panel-GD1 & GD2 as
Sets 0.00 0 0.00
described above

15 UPS Panel- 5A1 & 5A2


A INCOMER
2 Nos. 63A 4P Change Over Switch
2 nos.63A 4 pole MCCB (25KA) with over-rated neutral.
B METERING & INDICATION
i) 2 sets. of R,Y,B phase indicating lamps
ii) 2 Sets of Breaker ON-OFF-TRIP indication Lamps.
2 sets of Digital Multifunction meter for Voltage, Current & KW with selector switch.
iii)
Each with 3nos. Of 2A SP MCB & 3nos 60/5A CTs (60A/500V) rating
C BUS COUPLER:-
i) 1 No. 63A FP MCCB (25KA) with over-rated neutral.
ii) 1 Set of Breaker ON-OFF-TRIP indication Lamps .
D INTERLOCKING.
Incomer-1, Incomer-2 & Bus coupler shall be electrically & mechanically interlocked.
E BUS BAR:-
2 Set of 100A, FP Al.bus bar with colour coded PVC sleeves
F OUTGOINGS
i) 6 Nos. 40A FP MCB (10KA)
ii) 2 Nos. 63A FP MCB (10KA)
Supply of UPS Panel-5A1 & 5A2 as described above Set 0.00 0 0.00
Sub-Head-I : Preamble to BOQ for MV Panels
Item Quantity Amount
S.N. Description Unit Rate Remarks
code DSR NON DSR DSR NON DSR
Receiving, fixing, testing & commissioning of UPS Panel-5A1 & 5A2 as
Set 0.00 0 0.00
described above

16 UPS Panel- 6D1 & 6D2 (ICU Panel)


A INCOMER
2 Nos. 125A 4P Change Over Switch
2 nos.125A 4 pole MCCB (25KA) with over-rated neutral.
B METERING & INDICATION
i) 2 sets. of R,Y,B phase indicating lamps
ii) 2 Sets of Breaker ON-OFF-TRIP indication Lamps.
2 sets of Digital Multifunction meter for Voltage, Current & KW with selector switch.
iii)
Each with 3nos. Of 2A SP MCB & 3nos 125/5A CTs (125A/500V) rating
C BUS COUPLER:-
i) 1 No. 100A FP MCCB (25KA) with over-rated neutral.
ii) 1 Set of Breaker ON-OFF-TRIP indication Lamps .
D INTERLOCKING.
Incomer-1, Incomer-2 & Bus coupler shall be electrically & mechanically interlocked.
E BUS BAR:-
2 Set of 200A, FP Al.bus bar with colour coded PVC sleeves
F OUTGOINGS
i) 4 Nos. 40A DP MCB (10KA)
ii) 6 Nos. 63A DP MCB (10KA)
Supply of UPS Panel-6D1 & 1D2 as described above Set 130000.00 2 260000.00
Receiving, fixing, testing & commissioning of UPS Panel-6D1 & 6D2 as
Set 2000.00 2 4000.00
described above

17 UPS Panel- 6A1 & 6A2,6B3 & 6B4 (OT Panel)


A INCOMER
2 Nos. 160A 4P Change Over Switch
2 nos.160A 4 pole MCCB (25KA) with over-rated neutral.
B METERING & INDICATION
i) 2 sets. of R,Y,B phase indicating lamps
ii) 2 Sets of Breaker ON-OFF-TRIP indication Lamps.
2 sets of Digital Multifunction meter for Voltage, Current & KW with selector switch.
iii)
Each with 3nos. Of 2A SP MCB & 3nos 160/5A CTs (160A/500V) rating
C BUS COUPLER:-
i) 1 No. 125A FP MCCB (25KA) with over-rated neutral.
ii) 1 Set of Breaker ON-OFF-TRIP indication Lamps .
D INTERLOCKING.
Incomer-1, Incomer-2 & Bus coupler shall be electrically & mechanically interlocked.
E BUS BAR:-
2 Set of 200A, FP Al.bus bar with colour coded PVC sleeves
F OUTGOINGS
i) 2 Nos. 32A FP MCB (10KA)
ii) 10 Nos. 63A FP MCB (10KA)
Supply of UPS Panel-1A1 & 1A2 as described above Sets 141000.00 4 564000.00
Receiving, fixing, testing & commissioning of UPS Panel-1A1 & 1A2 as
Sets 3000.00 4 12000.00
described above
Sub-Head-I : Preamble to BOQ for MV Panels
Item Quantity Amount
S.N. Description Unit Rate Remarks
code DSR NON DSR DSR NON DSR
18 UPS Panel- GA1 & GA2 ,GB3 & GB4
A INCOMER
2 nos.63A 4 pole MCCB (25KA) with over-rated neutral.
B METERING & INDICATION
i) 2 sets. of R,Y,B phase indicating lamps
ii) 2 Sets of Breaker ON-OFF-TRIP indication Lamps.
2 sets of Digital Multifunction meter for Voltage, Current & KW with selector switch.
iii)
Each with 3nos. Of 2A SP MCB & 3nos 60/5A CTs (60A/500V) rating
C BUS COUPLER:-
i) 1 No. 40A FP MCCB (25KA) with over-rated neutral.
ii) 1 Set of Breaker ON-OFF-TRIP indication Lamps .
D INTERLOCKING.
Incomer-1, Incomer-2 & Bus coupler shall be electrically & mechanically interlocked.
E BUS BAR:-
2 Set of 100A, FP Al.bus bar with colour coded PVC sleeves
F OUTGOINGS
i) 4 Nos. 32A DP MCB (10KA)
ii) 4 Nos. 40A DP MCB (10KA)
Supply of UPS Panel-GA1 & GA2 as described above Sets 84700.00 4 338800.00
Receiving, fixing, testing & commissioning of UPS Panel-GA1 & GA2 as
Sets 2000.00 4 8000.00
described above

19 SDB- UPS-G1
A INCOMER
1 no. 63A 4 pole MCB (10KA)
B METERING & INDICATION
i) 1 No. (0-500V) Voltmeter with Built-in VSS with 3 nos. 2A SP MCB
ii) 1 No. (0-60A) Ammeter with ASS with 3 nos. 60/5A CTs
D OUTGOINGS
i) 3 Nos. 25A / 32A DP MCB (10KA)
ii) 2 Nos. 40A FP MCB (10KA)
Supply of SDB-UPS-G1 as described above Set 0.00 0 0.00
Receiving, fixing, testing & commissioning of SDB-UPS-G1 as described
Set 0.00 0 0.00
above

20 SDB- UPS-G2,G3
A INCOMER
1 no. 63A 4 pole MCB (10KA)
B METERING & INDICATION
i) 1 No. (0-500V) Voltmeter with Built-in VSS with 3 nos. 2A SP MCB
ii) 1 No. (0-60A) Ammeter with ASS with 3 nos. 60/5A CTs
D OUTGOINGS
i) 2 Nos. 25A / 32A DP MCB (10KA)
ii) 2 Nos. 40A DP MCB (10KA)
Supply of SDB-UPS-G2 as described above Sets 0.00 0 0.00
Receiving, fixing, testing & commissioning of SDB-UPS-G2 as described
Sets 0.00 0 0.00
above

21 SDB- UPS-21 (typ.for SDB-UPS-22,23)


A INCOMER
Sub-Head-I : Preamble to BOQ for MV Panels
Item Quantity Amount
S.N. Description Unit Rate Remarks
code DSR NON DSR DSR NON DSR
1 no. 63A 4 pole MCB (10KA)
B METERING & INDICATION
i) 1 No. (0-500V) Voltmeter with Built-in VSS with 3 nos. 2A SP MCB
ii) 1 No. (0-60A) Ammeter with ASS with 3 nos. 60/5A CTs
D OUTGOINGS
i) 1 No. 25A / 32A DP MCB (10KA)
ii) 3 Nos. 40A DP MCB (10KA)
Supply of SDB-UPS-21 as described above Sets 0.00 0 0.00
Receiving, fixing, testing & commissioning of SDB-UPS-21 as described
Sets 0.00 0 0.00
above

22 SDB- UPS-31 (typ.for SDB-UPS-32,33)


A INCOMER
1 no. 63A 4 pole MCB (10KA)
B METERING & INDICATION
i) 1 No. (0-500V) Voltmeter with Built-in VSS with 3 nos. 2A SP MCB
ii) 1 No. (0-60A) Ammeter with ASS with 3 nos. 60/5A CTs
D OUTGOINGS
i) 3 Nos. 25A / 32A DP MCB (10KA)
ii) 1 No. 40A DP MCB (10KA)
Supply of SDB-UPS-31 as described above Sets 0.00 0 0.00
Receiving, fixing, testing & commissioning of SDB-UPS-31 as described
Sets 0.00 0 0.00
above

23 SDB- UPS-11 (typ.for SDB-UPS-12; 41; 42; 52,53)


A INCOMER
1 no. 40A 4 pole MCB (10KA)
B METERING & INDICATION
i) 1 No. (0-500V) Voltmeter with Built-in VSS with 3 nos. 2A SP MCB
ii) 1 No. (0-40A) Ammeter with ASS with 3 nos. 40/5A CTs
D OUTGOINGS
4 Nos. 25A / 32A DP MCB (10KA)
Supply of SDB-UPS-11 as described above Sets 0.00 0 0.00
Receiving, fixing, testing & commissioning of SDB-UPS-11 as described
Sets 0.00 0 0.00
above

24 MDB-Lift Panel-1
A INCOMER
1 No. 400A FP MCCB (35 KA) with E/f Module & Core Balancing type CT (CBCT)
complete.
B METERING & INDICATION
i) 1 set. of R,Y,B phase indicating lamps
ii) 1 set of Breaker ON-OFF-TRIP indication Lamps.
1 set of Digital Multifunction meter for Voltage, Current & KW with selector switch.
iii)
Each with 3nos. Of 2A SP MCB & 3nos 400/5A CTs (400A/500V) rating
C BUS COUPLER:-
i) 1 No. 250A FP MCCB with all accessories required.
ii) 1 Set of Breaker ON-OFF-TRIP indication Lamps .
D INTERLOCKING.
Incomer-1, Bus coupler & Incomer-2 of MDB Lift Panel-2 shall be mechanically
interlocked.
Sub-Head-I : Preamble to BOQ for MV Panels
Item Quantity Amount
S.N. Description Unit Rate Remarks
code DSR NON DSR DSR NON DSR
E BUS BAR:-
1 Sets of 400A, TPN Al.bus bar with colour coded PVC sleeves
F OUTGOINGS
i) 4 No. 63A TPN MCCB (35KA)
ii) 6 Nos.125A TPN MCCB (35 KA)
iii) 2 Nos. 160A TPN MCCB (35KA)
Supply of MDB Lift Panels-1 as described above Set 267000.00 1 267000.00
Receiving, fixing, testing & commissioning of MDB Lift Panel-1 as described
Set 4000.00 1 4000.00
above

25 MDB-Lift Panel-2
A INCOMER
1 No. 400A FP MCCB (35 KA) with E/f Module & Core Balancing type CT (CBCT)
complete.
B METERING & INDICATION
i) 1 set. of R,Y,B phase indicating lamps
ii) 1 set of Breaker ON-OFF-TRIP indication Lamps.
1 set of Digital Multifunction meter for Voltage, Current & KW with selector switch.
iii)
Each with 3nos. Of 2A SP MCB & 3nos 400/5A CTs (400A/500V) rating
D INTERLOCKING.
Incomer-2 and Bus coupler & Incomer-1of MDB Lift Panel-1 shall be mechanically
interlocked.
E BUS BAR:-
1 Sets of 400A, TPN Al.bus bar with colour coded PVC sleeves
F OUTGOINGS
i) 2 Nos. 63A TPN MCCB (35KA)
ii) 2 Nos. 80A TPN MCCB (35 KA)
iii) 2 Nos. 125A TPN MCCB (35KA)
Supply of MDB Lift Panels-2 as described above Set 198000.00 1 198000.00
Receiving, fixing, testing & commissioning of MDB Lift Panel-2 as described
Set 3000.00 1 3000.00
above

26 Lift Panel-C3,B2,B3
A INCOMER
1 No. 63 A, 4 pole MCCB (16KA)
B METERING & INDICATION
i) 1 set of phase indicating lamps
ii) 1 No. (0-500V) Voltmeter with Built-in VSS with 3 nos. 2A SP MCB
iii) 1 No. (0-60A) Ammeter with ASS with 3 nos. 60/5A CTs
C INTERLOCKING.
Incomer-2 and Bus coupler & Incomer-1of MDB Lift Panel-1 shall be mechanically
interlocked.
D BUS BAR:-
1 Set of 100A, TPN Aluminium bus bar with colour coded PVC sleeves
E OUTGOINGS
i) 1 No. 20A DP MCB (10KA)
ii) 2 Nos. 63A TPN MCB (10KA)
Supply of Lift Panel-D2 as described above Sets 25000.00 5 125000.00
Receiving, fixing, testing & commissioning of Lift Panel-D2 as described
Sets 1000.00 5 5000.00
above
Sub-Head-I : Preamble to BOQ for MV Panels
Item Quantity Amount
S.N. Description Unit Rate Remarks
code DSR NON DSR DSR NON DSR
27 Lift Panel-A1,C1 ,C2,C3
A INCOMER
1 No. 125A, TPN MCCB (16KA)
B METERING & INDICATION
i) 1 set of phase indicating lamps
ii) 1 No. (0-500V) Voltmeter with Built-in VSS with 3 nos. 2A SP MCB
iii) 1 No. (0-125A) Ammeter with ASS with 3 nos. 125/5A CTs
C BUS BAR:-
1 Set of 150A, TPN Aluminium bus bar with colour coded PVC sleeves
D OUTGOINGS
i) 1 No. 32A DP MCB (10KA)
ii) 1 No. 40A TPN MCB (10KA)
iii) 3 Nos. 63A TPN MCB (10KA)
Supply of Lift Panel-C2 as described above Sets 26000.00 7 182000.00
1 Added for
Receiving, fixing, testing & commissioning of Lift Panel-C2 as described Type VII
Sets 1000.00 7 7000.00
above

28 Lift Panel-B1
A INCOMER
1 No. 160A, TPN MCCB (16KA)
B METERING & INDICATION
i) 1 set of phase indicating lamps
ii) 1 No. (0-500V) Voltmeter with Built-in VSS with 3 nos. 2A SP MCB
iii) 1 No. (0-160A) Ammeter with ASS with 3 nos. 160/5A CTs
C BUS BAR:-
1 Set of 200A, TPN Aluminium Bus bar with colour coded PVC sleeves
D OUTGOINGS
i) 1 No. 32A DP MCB (10KA)
ii) 3 No. 40A TPN MCB (10KA)
iii) 4 Nos. 63A TPN MCB (16KA)
Supply of Lift Panel-A1 as described above Set 32800.00 1 32800.00
Receiving, fixing, testing & commissioning of Lift Panel-A as described above Set 1000.00 1 1000.00

29 SDB - CSSD
A INCOMER
1 No. 400A FP MCCB (35 KA) with E/f Module & Core Balancing type CT (CBCT)
complete.
B METERING & INDICATION
i) 1 set. of R,Y,B phase indicating lamps
ii) 1 set of Breaker ON-OFF-TRIP indication Lamps.
1 set of Digital Multifunction meter for Voltage, Current & KW with selector switch.
iii)
Each with 3nos. Of 2A SP MCB & 3nos 400/5A CTs (400A/500V) rating
C BUS BAR:-
1 Set of 200A, TPN Aluminium Bus bar with colour coded PVC sleeves
D OUTGOINGS
i) 2 Nos. 100A FP MCCB (35KA)
ii) 8 Nos. 63A FP MCCB (35KA)
iii) 4 Nos. 40A FP MCCB (35KA)
Supply of SDB - CSSD as described above Set 325000.00 2 650000.00
Sub-Head-I : Preamble to BOQ for MV Panels
Item Quantity Amount
S.N. Description Unit Rate Remarks
code DSR NON DSR DSR NON DSR
Receiving, fixing, testing & commissioning of SDB - CSSD as described
Set 4000.00 2 8000.00
above

30 SDB - LAUNDRY
A INCOMER
1 No. 300 A 4 pole MCCB (35KA)
B METERING & INDICATION
i) 1 set of phase indicating lamps
ii) 1 No. (0-500V) Voltmeter with Built-in VSS with 3 nos. 2A SP MCB
iii) 1 No. (0-300A) Ammeter with ASS with 3 nos. 300/5A CTs
C BUS BAR:-
1 Set of 300A, TPN Aluminium Bus bar with colour coded PVC sleeves
D OUTGOINGS
i) 2 Nos. 63A FP MCCB (35KA)
ii) 4 Nos. 40A FP MCCB (35KA)
iii) 4 Nos. 32A FP MCB (10KA)
iv) 8 Nos. 32A DP MCB (10KA)
Supply of SDB - Laundry as described above Set 0.00 0 0.00
Receiving, fixing, testing & commissioning of SDB - Laundry as described
Set 0.00 0 0.00
above

31 SDB - KITCHEN
A INCOMER
1 No. 400 A 4 pole MCCB (25KA)
B METERING & INDICATION
i) 1 set of phase indicating lamps
ii) 1 No. (0-500V) Voltmeter with Built-in VSS with 3 nos. 2A SP MCB
iii) 1 No. (0-200A) Ammeter with ASS with 3 nos. 200/5A CTs
C BUS BAR:-
1 Set of 250A, TPN Aluminium Bus bar with colour coded PVC sleeves
D OUTGOINGS
i) 2 Nos. 100A FP MCCB (25KA)
ii) 3 Nos. 63A FP MCCB (25KA)
iii) 3 Nos. 40A FP MCCB (25KA)
iv) 4 Nos. 32A FP MCB (10KA)
v) 4 Nos. 20A FP MCB (10KA)
vi) 8 Nos. 32A DP MCB (10KA)
Supply of SDB - Kitchen as described above Set 235800.00 1 235800.00
Receiving, fixing, testing & commissioning of SDB - Kitchen as described
Set 4000.00 1 4000.00
above

32 SDB - RADIOLOGY
A INCOMER
1 No. 125 A, 4 pole MCCB (25KA)
B METERING & INDICATION
i) 1 set of phase indicating lamps
ii) 1 No. (0-500V) Voltmeter with Built-in VSS with 3 nos. 2A SP MCB
iii) 1 No. (0-100A) Ammeter with ASS with 3 nos. 100/5A CTs
C BUS BAR:-
1 Set of 150A, TPN Aluminium Bus bar with colour coded PVC sleeves
D OUTGOINGS
Sub-Head-I : Preamble to BOQ for MV Panels
Item Quantity Amount
S.N. Description Unit Rate Remarks
code DSR NON DSR DSR NON DSR
i) 11 Nos. 32A DP MCB (25KA)
ii) 1 Nos. 20A DP MCB (25KA)
iii) 6 Nos. 20A / 32A FP MCB (10KA)
Supply of SDB - Radiology as described above Set 38600.00 1 38600.00
Receiving, fixing, testing & commissioning of SDB - Radiology as described
Set 1000.00 1 1000.00
above

33 ISOLATION PANEL
Design, fabrication, supply, erction, testing & commissioning of surface/ recessed
mouted 16 SWG Stainless steel body, compartmantallised with hinged door
Isolation panel as per technical specification, complete with the following:
33.1 Isolation panel - Type-1 (for OTs)
A INCOMER
1No. 63A DP MCB(10KA)
1No. 63A DP ELCB(300mA)
B METERING & INDICATION
i) 1 set of ON /OFF indicating lamps
ii) 1 No. (0-500V) Voltmeter (size-72 sq.mm.) with Built-in VSS with 2A SP MCB
iii) 1 No. (0-63A) Ammeter
iv) Scale Selection Indicator (5mA-10mA) with selector switch for LIM
v) Green indication lamp for safe zone
vi) Red indication lamp for hazard zone
vii) 1 No. Buzzer for Alarm
C LINE ISOLATION MONITOR
Solid state Line isolation monitor suitable for detecting 2-4 mA (adjustable) leaKAge
current
D TRANSFORMER
1 no. 12.5 KVA, Single Phase, air cooled, copper conductor, double wound core
type Isolation transformer
E OUTGOINGS
12 Nos 6A /16A SP MCB(10KA)
Supply of Isolation Panel(Type-1) as described above Sets 0.00 0 0.00
Receiving, fixing, testing & commissioning of Isolation Panel(Type-1) as
Sets 0.00 0 0.00
described above

33.2 Isolation panel - Type-2 (for ICUs)


A INCOMER
i) 1No. 63A DP MCB(10KA)
ii) 1No. 63A DP ELCB(300mA)
B METERING & INDICATION
i) 1 set of ON /OFF indicating lamps
ii) 1 No. (0-500V) Voltmeter (size-72 sq.mm.) with Built-in VSS with 2A SP MCB
iii) 1 No. (0-40A) Ammeter
iv) Scale Selection Indicator (5mA-10mA) with selector switch for LIM
v) Green indication lamp for safe zone
vi) Red indication lamp for hazard zone
vii) 1 No. Buzzer for Alarm
C LINE ISOLATION MONITOR
Solid state Line isolation monitor suitable for detecting 2-4 mA (adjustable) leaKAge
current
D TRANSFORMER
Sub-Head-I : Preamble to BOQ for MV Panels
Item Quantity Amount
S.N. Description Unit Rate Remarks
code DSR NON DSR DSR NON DSR
1 no 10 KVA, Single Phase, air cooled, copper conductor, double wound core type
Isolation transformer
E OUTGOINGS
20 Nos 6A /16A SP MCB (10KA)
Supply of Isolation Panel(Type-2) as described above Sets 319500.00 7 2236500.00
Receiving, fixing, testing & commissioning of Isolation Panel(Type-2) as
Sets 3000.00 7 21000.00
described above

33.3 Isolation panel - Type-3 (for ICUs)


A INCOMER
i) 1No. 63A DP MCB(10KA)
ii) 1No. 63A DP ELCB(300mA)
B METERING & INDICATION
i) 1 set of ON /OFF indicating lamps
ii) 1 No. (0-500V) Voltmeter (size-72 sq.mm.) with Built-in VSS with 2A SP MCB
iii) 1 No. (0-40A) Ammeter
iv) Scale Selection Indicator (5mA-10mA) with selector switch for LIM
v) Green indication lamp for safe zone
vi) Red indication lamp for hazard zone
vii) 1 No. Buzzer for Alarm
C LINE ISOLATION MONITOR
Solid state Line isolation monitor suitable for detecting 2-4 mA (adjustable) leaKAge
current
D TRANSFORMER
1 no 10 KVA, Single Phase, air cooled, copper conductor, double wound core type
Isolation transformer
E OUTGOING
14 Nos 6A /16A SP MCB (10KA)
Supply of Isolation Panel(Type-3) as described above Sets 0.00 0 0.00
Receiving, fixing, testing & commissioning of Isolation Panel(Type-3) as
Sets 0.00 0 0.00
described above

33.4 Isolation panel - Type-4 (for Casualty)


A INCOMER
i) 1No. 63A DP MCB(10KA)
ii) 1No. 63A DP ELCB(300mA)
B METERING & INDICATION
i) 1 set of ON /OFF indicating lamps
ii) 1 No. (0-500V) Voltmeter (size-72 sq.mm.) with Built-in VSS with 2A SP MCB
iii) 1 No. (0-40A) Ammeter
iv) Scale Selection Indicator (5mA-10mA) with selector switch for LIM
v) Green indication lamp for safe zone
vi) Red indication lamp for hazard zone
vii) 1 No. Buzzer for Alarm
C LINE ISOLATION MONITOR
Solid state Line isolation monitor suitable for detecting 2-4 mA (adjustable) leaKAge
current
D TRANSFORMER
1 no 7.5 KVA, Single Phase, air cooled, copper conductor, double wound core
type Isolation transformer
E OUTGOINGS
Sub-Head-I : Preamble to BOQ for MV Panels
Item Quantity Amount
S.N. Description Unit Rate Remarks
code DSR NON DSR DSR NON DSR
12 Nos 6A /16A SP MCB (10KA)
Supply of Isolation Panel(Type-4) as described above Sets 289000.00 3 867000.00
Receiving, fixing, testing & commissioning of Isolation Panel(Type-4) as
Sets 2000.00 3 6000.00
described above

33.5 Isolation panel - Type-5 (for NICU)


A INCOMER
i) 1No. 40A DP MCB(10KA)
ii) 1No. 40A DP ELCB(300mA)
B METERING & INDICATION
i) 1 set of ON /OFF indicating lamps
ii) 1 No. (0-500V) Voltmeter (size-72 sq.mm.) with Built-in VSS with 2A SP MCB
iii) 1 No. (0-40A) Ammeter
iv) Scale Selection Indicator (5mA-10mA) with selector switch for LIM
v) Green indication lamp for safe zone
vi) Red indication lamp for hazard zone
vii) 1 No. Buzzer for Alarm
C LINE ISOLATION MONITOR
Solid state Line isolation monitor suitable for detecting 2-4 mA (adjustable) leaKAge
current
D TRANSFORMER
1 no 5 KVA, Single Phase, air cooled, copper conductor, double wound core type
Isolation transformer
E OUTGOINGS
12 Nos 6A /16A SP MCB (10KA)
Supply of Isolation Panel(Type-5) as described above Sets 232000.00 11 2552000.00
Receiving, fixing, testing & commissioning of Isolation Panel(Type-5) as
Sets 2000.00 11 22000.00
described above

Supply, Design, fabrication, installation, testing & commissioning of DOL starters


for Sump Pumps (1W+1S) in powder coated MS enclosure complete with suitable
34 rating of Contactor & Over load relay suitable for 3 HP Motors complete with 2 sets Sets 20000.00 10 200000.00
of Level controller. The starter shall operate the two motors in such a way that they
will start/ stop automaticaly at preset liquid level ias per thier level controller.

35 Bus Trunking :
Design, supply, installation, testing and commisioning of following ratings of powder
coated sheet steel enclosed (IP 42) 415V, 50 Hz., Three phase & neutral
Sandwich type Aluminium conductor Bus Duct suitable for 35 MVA fault rating,
including bends/elbows, transposition piece, expansion joint, Terminal End
connector & all flexible connections as per specifications with all accessories,
supports, hardwares and termination of bus duct to switchgear.
1250A, TPN Aluminium Bus Duct Riser Main with provision for mounting of 2
36 RM 16000.00 235 3760000.00
nos.of Tap-off in every 4.0 meter length (height per floor)
Notes:
The procurement of bus duct/ riser mains shall be taken up only after actual
measurement and site routing. Necessary bends expansion joints and transposition
i)
pieces after every 10m or as per local rules whichever is stringent shall be
estimated & included. Payment will be made on running meter basis.
The supply and fabrication of structural steel for bus duct support shall be paid
ii)
separately.
Sub-Head-I : Preamble to BOQ for MV Panels
Item Quantity Amount
S.N. Description Unit Rate Remarks
code DSR NON DSR DSR NON DSR

37 Tap OFF Box with Isolator


Design, supply, installation, testing & commissioning of following ratings of powder
coated sheet steel enclosed, 415V Three phase & neutral suitable for 25 MVA fault
rating & Indoor application, Aluminium conductor Tap-OFF Box with TPN Isolator
i)
for Sandwich type Bus duct riser main as per specifications with all accessories,
supports, hardwares and termination of switchgear as required. The Tap-Box shall
be suitable for mechanical interlock.
a 500A TPN Tap-OFF Box with 500A TPN Isolator Sets 32300.00 2 64600.00
b 400A TPN Tap-OFF Box with 400A TPN Isolator Sets 0.00 0 0.00
c 300A TPN Tap-OFF Box with 400A TPN Isolator Sets 21400.00 2 42800.00
d 250A TPN Tap-OFF Box with 250A TPN Isolator Set 18300.00 28 512400.00
e 200A TPN Tap-OFF Box with 200A TPN Isolator Sets 13900.00 16 222400.00
f 160A TPN Tap-OFF Box with 160A TPN Isolator Sets

38 Adaptor Box/ End feed Cable Unit

Design, supply, installation, testing & commissioning of following ratings of powder


coated sheet steel enclosed, 415V Three phase & neutral suitable for 35 MVA fault
rating & Indoor application, Aluminium conductor Adaptor box/ End Feed Cable
Unit Box with MCCB for Sandwich type Bus duct riser main as per specifications
with all accessories, supports, hardwares and termination of switchgear as
required. The Adaptor Box shall be suitable for mechanical interlock with Bus Duct
including cable termination box suitable for 6 Nos 300 Sq.mm XLPE Al Ar Cable.

a 1250A TPN Adaptor Box with 1250A FP MDO ACB(35KA) with SR 18 release Sets 111100.00 6 666600.00
b 1250A TPN ISOLATOR Sets 100500.00 6 603000.00

Supply & erection of Spring support for Vertical Installation of Riser main fabricated
from not less than ISMC75 G.I. Channels & ISA 50 G.I.Angles (ISA75), 3mm. Thick
39 G.I. flats,suitable size of Helixical Spring etc., as required for the size & weight ot Sets 3200.00 162 518400.00
support complete with all accessories & hardwares as required for fixing including
providing of not less than 2.5mm thick G.I. Floor Flange for sealing.

Total of HOSPITAL BLOCK

MEDICAL COLLEGE
Sub-Head-I : Panels & Distribution boards
Sub-Head-I : Preamble to BOQ for MV Panels
Item Quantity Amount
S.N. Description Unit Rate Remarks
code DSR NON DSR DSR NON DSR

Design, Fabrication, Supply, Erection,Testing and commisioning of Powder coated


Main Distribution Panel fabricated out of 14 guage CRCA sheet steel in cubical,
compartmentallised free standing floor /wall mounted, dust and vermin proof, with
reinforcement of suitable size angle iron, channel, T -iron or flats as required. Cable
gland plates shall be provided on top as well as bottom of the panels. Panels shall
be treated with all anti-corrosive process before painting complete as per
specification & SLD. Panels shall be suitable for 415V, 3-Phase, Four wire, 50 Hz
supply complete with earth bus and lifting hooks as required in case of large
panels.Approval shall be taken for each panel before fabrication. (All hardwares like
nuts and bolts used shall be Galvanized and Zinc passivated) (Note: Contractor
can select the next higher fault rating of MCCB if it is not readily available, without
any extra cost, as the figure indicated within the bracket are required maximum
fault level of that panel)

1 MDB-1 (Medical College) (LHS)


A INCOMER
2 No. 630A FP MCCB (35 KA) with E/f Module & Core Balancing type CT (CBCT)
i)
complete.
B METERING & INDICATION
i) 2 Sets of R,Y,B phase indicating lamps
ii) 2 Nos. (0-500V) Voltmeter with VSS with 3 nos. 2A SP MCB.
iii) 2 Nos. (0-630A) Ammeter with ASS with 3 nos.630/5A CT's.
iv) 2 Nos. 630/5A Cl.1 CT for APFC Relay.in Capacitor panel.
C BUS-BAR
i) 1 Sets of 800A TPN Aluminium Bus Bar with colour coded PVC Sleeves
D BUS COUPLER:-
i) 1 No. 630A FP MCCB (25KA)
ii) 1 Set of Breaker ON-OFF-TRIP indication Lamps .
E INTERLOCKING.
Incomer-1, Incomer-2 & Bus coupler shall be electrically & mechanically interlocked.
F OUTGOINGS
i) 1 No.400A FP MCCB (25KA)
ii) 10 No.160A FP MCCB (25KA)
iii) 5 Nos. 40A FP MCB (16KA)
Supply of MDB-1 as described above. Set 0.00 0.00 0 0.00
Receiving, fixing, testing & commissioning of MDB-1 Set 0.00 0 0.00

2 MDB-2 (Medical College) (RHS)


A INCOMER
2 No. 630A FP MCCB (35 KA) with E/f Module & Core Balancing type CT (CBCT)
i)
complete.
B METERING & INDICATION
i) 2 Sets of R,Y,B phase indicating lamps
ii) 2 Nos. (0-500V) Voltmeter with VSS with 3 nos. 2A SP MCB.
iii) 2 Nos. (0-630A) Ammeter with ASS with 3 nos.630/5A CT's.
iv) 2 Nos. 630/5A Cl.1 CT for APFC Relay.in Capacitor panel.
C BUS-BAR
i) 1 Sets of 800A TPN Aluminium Bus Bar with colour coded PVC Sleeves
D BUS COUPLER:-
i) 1 No. 630A FP MCCB (25KA)
ii) 1 Set of Breaker ON-OFF-TRIP indication Lamps .
E INTERLOCKING.
Sub-Head-I : Preamble to BOQ for MV Panels
Item Quantity Amount
S.N. Description Unit Rate Remarks
code DSR NON DSR DSR NON DSR
Incomer-1, Incomer-2 & Bus coupler shall be electrically & mechanically interlocked.
F OUTGOINGS
i) 1 No.400A FP MCCB (25KA)
ii) 10 No.160A FP MCCB (25KA)
iii) 7 Nos. 40A FP MCB (16KA)
Supply of MDB-2 as described above. Set 0.00 0 0.00
Receiving, fixing, testing & commissioning of MDB-2 Set 0.00 0 0.00

3 SDB-1 & SDB-2 (Ground floor) (Typical For First to Fourth )


A INCOMER
1 No. 160A FP MCCB (16 KA) with E/f module & Core Balancing type CT (CBCT)
i)
complete.
B METERING & INDICATION
i) 1 Sets of R,Y,B phase indicating lamps
ii) 1 Nos. (0-500V) Voltmeter with VSS with 3 nos. 2A SP MCB.
iii) 1 Nos. (0-160A) Ammeter with ASS with 3 nos. 160/5A CT's.
C BUS-BAR
i) 1 Sets of 200A TPN Aluminium Bus Bar with colour coded PVC Sleeves
D OUTGOINGS
i) 4 Nos. 63A FP MCB (10KA)
ii) 8 Nos. 40A FP MCB (10KA)
iii) 2 Nos. 32A FP MCB (10KA)
Supply of SDB-1 (Ground floor) (Typical For first,second,Third,Fourth ) as
Sets 67000.00 2 134000.00
described above.
Receiving, fixing, testing & commissioning of SDB-1 (Ground floor) (Typical
Sets 1000.00 2 2000.00
For first,second,Third,Fourth ) as described above

4 SDB-1 & SDB-2 (Fifth Floor)


A INCOMER
1 No. 200A FP MCCB (16 KA) with E/f module & Core Balancing type CT (CBCT)
i)
complete.
B METERING & INDICATION
i) 1 Sets of R,Y,B phase indicating lamps
ii) 1 Nos. (0-500V) Voltmeter with VSS with 3 nos. 2A SP MCB.
iii) 1 Nos. (0-200A) Ammeter with ASS with 3 nos. 200/5A CT's.
C BUS-BAR
i) 1 Sets of 200A TPN Aluminium Bus Bar with colour coded PVC Sleeves
D OUTGOINGS
i) 3 Nos. 63A FP MCB (10KA)
ii) 7 Nos. 40A FP MCB (10KA)
iii) 1 Nos. 32A FP MCB (10KA)
Supply of SDB-1 & SDB-2 as described above. Sets 66000.00 12 792000.00
Receiving, fixing, testing & commissioning of SDB-1 & SDB-2 (Fifth Floor) as
Sets 1000.00 12 12000.00
described above

5 SDB-1 & SDB-2 ( For UPS)


A INCOMER
1 No. 160A FP MCCB (16 KA) with E/f module & Core Balancing type CT (CBCT)
i)
complete.
B METERING & INDICATION
Sub-Head-I : Preamble to BOQ for MV Panels
Item Quantity Amount
S.N. Description Unit Rate Remarks
code DSR NON DSR DSR NON DSR
i) 1 Sets of R,Y,B phase indicating lamps
ii) 1 Nos. (0-500V) Voltmeter with VSS with 3 nos. 2A SP MCB.
iii) 1 Nos. (0-160A) Ammeter with ASS with 3 nos. 160/5A CT's.
C BUS-BAR
i) 1 Sets of 200A TPN Aluminium Bus Bar with colour coded PVC Sleeves
D OUTGOINGS
ii) 14 Nos. 40A DP MCB (10KA)
Supply of SDB-1 & SDB-2 ( For UPS) as described above. Sets 49000.00 2 98000.00
Receiving, fixing, testing & commissioning of SDB-1 & SDB-2 (For UPS) as
Sets 1000.00 2 2000.00
described above
6
CAPACITOR PANEL-150 KVAR
A INCOMER
1 no. 400A TPN Isolator
B METERING & INDICATION
i) 1 set of phase indicating lamps
ii) 1 No. (0-500V) Voltmeter with Built-in VSS with 3 nos. 2A SP MCB
iii) 1 No. 8 step APFC relay
C BUS-BAR
1 Set of 400A TP Al. Bus Bar with colour coded PVC Sleeves
D OUTGOINGS
i) 5 Nos. of 63A TP MCB(10 KA) with 70A TP contactor (AC-3 duty)
ii) 3 Nos. of 20A/ 32A TP MCB(10 KA) with 30A/ 40A TP contactor (AC-3 duty)
iii) 8 Sets self Illuminated Red-Green (ON-OFF) push buttons.
iv) 5 Nos. 25 KVAR capacitor Bank with harmonic filter & discharge resistor.
v) 2 Nos. 10 KVAR capacitor Bank with harmonic filter & discharge resistor.
vi) 1 No. 5 KVAR capacitor Bank with harmonic filter & discharge resistor.
Supply of Capacitor Panel as described above Sets 405000.00 4 1620000.00
Receiving, fixing, testing & commissioning of Capacitor Panel as described
Sets 2500.00 4 10000.00
above

7 MDB (Auditorium)
A INCOMER
2 No.250A FP MCCB (25 KA) with E/f Module & Core Balancing type CT (CBCT)
i)
complete.
B METERING & INDICATION
i) 2 Set of R,Y,B phase indicating lamps
ii) 2 No. (0-500V) Voltmeter with VSS with 3 nos. 2A SP MCB
iii) 2 No. (0-250A) Ammeter with ASS with 3 nos. 250/5A CT's
C BUS-BAR
i) 1 Set of 300A TPN Aluminium Bus Bar with colour coded PVC Sleeves
D BUS COUPLER:-
i) 1 No. 250A FP MCCB (25KA) with over-rated neutral.
ii) 1 Set of Breaker ON-OFF-TRIP indication Lamps .
E INTERLOCKING.
Incomer-1, Incomer-2 & Bus coupler shall be electrically & mechanically interlocked.
F OUTGOINGS
i) 1 Nos.160A FP MCCB (25KA)
ii) 1 Nos.63A FP MCB (10KA)
iii) 8 Nos.40A FP MCB (10KA)
Sub-Head-I : Preamble to BOQ for MV Panels
Item Quantity Amount
S.N. Description Unit Rate Remarks
code DSR NON DSR DSR NON DSR
iv) 13 Nos.32A FP MCB (10KA)
Supply of MDB Audi as described above. Set 198000.00 1 198000.00
Receiving, fixing, testing & commissioning of MDB Audi Set 1500.00 1 1500.00

8 Ventilation Panel-1 (Loc.-Basement, Auditorium )


A INCOMER
1 nos. 160 A TPN MCCB (25KA) with E/f Module & Core Balancing type CT
(CBCT) complete.
B METERING & INDICATION
i) 1 setof R,Y,B phase indicating lamps
ii) 1 Set of Breaker ON-OFF-TRIP indication Lamps.
1 set of Digital Multifunction meter for Voltage, Current & KW with selector switch.
iii)
Each with 3nos. Of 2A SP MCB & 3nos 160/5A CTs (160A/500V) rating
C BUS BAR:-
1 Set of 200A, TPN Al.bus bar with colour coded PVC sleeves
D OUTGOINGS
i) 1 Nos.32A FP MCB (10KA)
ii) 8 Nos.40A TP MCB (10KA)
7set of S/D starter each with self illuminated Push button for ON & OFF and
iii)
suitable rating of contactor and O/L relays, suitable for 10 HP Motor.
Supply of Vent.Panel-1 as described above Set 0.00 0 0.00
Receiving, fixing, testing & commissioning of Vent. Panel-1 as described
Set 0.00 0 0.00
above

9 Ventilation Panel-1 & 2 (Loc.- Medical College, LHS & RHS )


A INCOMER
1 nos. 160 A TPN MCCB (25KA) with E/f Module & Core Balancing type CT
(CBCT) complete.
B METERING & INDICATION
i) 1 setof R,Y,B phase indicating lamps
ii) 1 Set of Breaker ON-OFF-TRIP indication Lamps.
1 set of Digital Multifunction meter for Voltage, Current & KW with selector switch.
iii)
Each with 3nos. Of 2A SP MCB & 3nos 160/5A CTs (160A/500V) rating
C BUS BAR:-
1 Set of 200A, TPN Al.bus bar with colour coded PVC sleeves
D OUTGOINGS
i) 1 Nos. 32A FP MCB (10KA)
ii) 5 Nos. 63A TP MCB (10KA)
4 set of S/D starter each with self illuminated Push button for ON & OFF and
iii)
suitable rating of contactor and O/L relays, suitable for 20 HP Motor.
Supply of Vent.Panel-1 & 2 as described above Sets 0.00 0 0.00
Receiving, fixing, testing & commissioning of Vent.Panel-1 & 2 as described
Sets 0.00 0 0.00
above

10 Pressurization fan Panel-1 (Medical College,LHS)


A INCOMER
i) 1 No. 160A TPN MCB (25 KA)
B METERING & INDICATION
i) 1 Sets of R,Y,B phase indicating lamps
ii) 1 Nos. (0-500V) Voltmeter with VSS with 3 nos. 2A SP MCB
Sub-Head-I : Preamble to BOQ for MV Panels
Item Quantity Amount
S.N. Description Unit Rate Remarks
code DSR NON DSR DSR NON DSR
iii) 1 Nos. (0-160A) Ammeter with ASS with 3 nos. 160/5A CT's
C BUS-BAR
i) 1 Sets of 200A TPN Aluminium Bus Bar with colour coded PVC Sleeves
D OUTGOINGS
i) 3 nos. 6A-32A TP MCB(10kA) as required
ii) 4 Nos.40A TP MCB (10KA)
iii) 2 no. DOL starter complete with Contactor & O/L relay suitable for 5 HP motor
3 no. Star-Delta starter complete with Contactor & O/L relay suitable for 15 HP
iv)
motor
Supply of Pressurization fan Panel-1 as described above. Set 0.00 0 0.00
Receiving, fixing, testing & commissioning of Pressurization fan Panel-1 Set 0.00 0 0.00

11 Pressurization fan Panel-2 (Medical College,RHS)


A INCOMER
i) 1 No. 160A TPN MCB (25 KA)
B METERING & INDICATION
i) 1 Sets of R,Y,B phase indicating lamps
ii) 1 Nos. (0-500V) Voltmeter with VSS with 3 nos. 2A SP MCB
iii) 1 Nos. (0-160A) Ammeter with ASS with 3 nos. 160/5A CT's
C BUS-BAR
i) 1 Sets of 200A TPN Aluminium Bus Bar with colour coded PVC Sleeves
D OUTGOINGS
i) 4 nos. 6A-32A TP MCB(10kA) as required
ii) 4 Nos.40A TP MCB (10KA)
iii) 3 no. DOL starter complete with Contactor & O/L relay suitable for 5 HP motor
3 no. Star-Delta starter complete with Contactor & O/L relay suitable for 15 HP
iv)
motor
Supply of Pressurization fan Panel-2 as described above. Set 0.00 0 0.00
Receiving, fixing, testing & commissioning of Pressurization fan Panel-2 Set 0.00 0 0.00

HOSTEL BLOCK
Sub-Head-I : Panels & Distribution boards (NS Items)

Design, Fabrication, Supply, Erection,Testing and commisioning of Powder coated


Main Distribution Panel fabricated out of 14 guage CRCA sheet steel in cubical,
compartmentallised free standing floor /wall mounted, dust and vermin proof, with
reinforcement of suitable size angle iron, channel, T -iron or flats as required. Cable
gland plates shall be provided on top as well as bottom of the panels. Panels shall
be treated with all anti-corrosive process before painting complete as per
specification & SLD. Panels shall be suitable for 415V, 3-Phase, Four wire, 50 Hz
supply complete with earth bus and lifting hooks as required in case of large
panels.Approval shall be taken for each panel before fabrication. (All hardwares like
nuts and bolts used shall be Galvanized and Zinc passivated) (Note: Contractor
can select the next higher fault rating of MCCB if it is not readily available, without
any extra cost, as the figure indicated within the bracket are required maximum
fault level of that panel)

1 MDB-1 , 2 & 3 for Boys Hostel & MDB-5 for Nurse Hostel)
A INCOMER
1 No. 400A FP MCCB (25 KA) with E/f module & Core Balancing type CT (CBCT)
a)
complete.
B METERING & INDICATION
Sub-Head-I : Preamble to BOQ for MV Panels
Item Quantity Amount
S.N. Description Unit Rate Remarks
code DSR NON DSR DSR NON DSR
a) 1 Sets of R,Y,B phase indicating lamps
b) 1 Nos. (0-500V) Voltmeter with VSS with 3 nos. 2A SP MCB
c) 1 Nos. (0-400A) Ammeter with ASS with 3 nos. 400/5A CT's
C BUS-BAR
a) 1 Sets of 400A TPN Aluminium Bus Bar with colour coded PVC Sleeves
D OUTGOINGS
a) 8 Nos. 80A FP MCCB (25KA)
b) 3 Nos. 63A TP MCCB (25KA)
c) 6 Nos. 63A FP MCB (10KA)
d) 2 Nos 40A DP MCB(10 KA)
Supply of MDB-1 Boys Hostel as described above Sets 0.00 0 0.00
Receiving, fixing, testing & commissioning of MDB-1 Boys Hostel & Nurse
Sets 0.00 0 0.00
Hostel

2 MDB-4 for Girls Hostel


A INCOMER
1 No. 500A FP MCCB (25 KA) with E/f module & Core Balancing type CT (CBCT)
a)
complete.
B METERING & INDICATION
a) 1 Sets of R,Y,B phase indicating lamps
b) 1 Nos. (0-500V) Voltmeter with VSS with 3 nos. 2A SP MCB
c) 1 Nos. (0-500A) Ammeter with ASS with 3 nos. 500/5A CT's
C BUS-BAR
a) 1 Sets of 600A TPN Aluminium Bus Bar with colour coded PVC Sleeves
D OUTGOINGS
a) 17 Nos. 80A FP MCCB (25KA)
b) 3 Nos. 63A TP MCCB (25KA)
c) 5 Nos. 63A FP MCB (10KA)
d) 5 Nos. 40A DP MCB (10KA)
Supply of MDB-4 Girls Hostel as described above. Set 446000.00 1 446000.00
Receiving, fixing, testing & commissioning of MDB-4 Girls Hostel Set 2500.00 1 2500.00

3 MDB-6 Guest House


A INCOMER
1 No. 250A FP MCCB (25 KA) with E/f module & Core Balancing type CT (CBCT)
a)
complete.
B METERING & INDICATION
a) 1 Sets of R,Y,B phase indicating lamps
b) 1 No. (0-500V) Voltmeter with VSS with 3 nos. 2A SP MCB
c) 1 No. (0-250A) Ammeter with ASS with 3 nos. 250/5A CT's
C BUS-BAR
a) 1 Sets of 400A TPN Aluminium Bus Bar with colour coded PVC Sleeves
D OUTGOINGS
a) 6 Nos. 80A FP MCCB (25KA)
b) 2 Nos. 63A TP MCCB (25KA)
c) 2 Nos. 40A DP MCB (16KA)
Supply of MDB-6 Guest House as described above. Set 195000.00 1 195000.00
Receiving, fixing, testing & commissioning of MDB-6 Guest House Set 2500.00 1 2500.00

4 MDB-7 Doctor Hostel


A INCOMER
Sub-Head-I : Preamble to BOQ for MV Panels
Item Quantity Amount
S.N. Description Unit Rate Remarks
code DSR NON DSR DSR NON DSR
1 No. 400A FP MCCB (25 KA) with E/f module & Core Balancing type CT (CBCT)
a)
complete.
B METERING & INDICATION
a) 1 Sets of R,Y,B phase indicating lamps
b) 1 Nos. (0-500V) Voltmeter with VSS with 3 nos. 2A SP MCB
c) 1 Nos. (0-400A) Ammeter with ASS with 3 nos. 400/5A CT's
C BUS-BAR
a) 1 Sets of 600A TPN Aluminium Bus Bar with colour coded PVC Sleeves
D OUTGOINGS
a) 8 Nos. 80A FP MCCB (25KA)
b) 3 Nos. 63A TP MCCB (25KA)
c) 5 Nos. 63A TPN MCB (10KA)
Supply of MDB-7 Doctor Hostel as described above. Set 0.00 0 0.00
Receiving, fixing, testing & commissioning of MDB-7 Doctor Hostel Set 0.00 0 0.00

5 MDB-8 Service Block


A INCOMER
1 No.500A FP MCCB (25 KA) with E/f Module & Core Balancing type CT (CBCT)
a)
complete.
B METERING & INDICATION
a) 1 Set of R,Y,B phase indicating lamps
b) 1 No. (0-500V) Voltmeter with VSS with 3 nos. 2A SP MCB
c) 1 No. (0-500A) Ammeter with ASS with 3 nos. 500/5A CT's
C BUS-BAR
a) 1 Set of 600A TPN Aluminium Bus Bar with colour coded PVC Sleeves
D OUTGOINGS
a) 5 Nos.100A FP MCCB (16KA)
b) 10 Nos.63A FP MCB (10KA)
c) 4 Nos.40A FP MCB (10KA)
Supply of MDB-8 Service Block as described above. Set 188000.00 1 188000.00
Receiving, fixing, testing & commissioning of MDB-8 Service Block Set 2500.00 1 2500.00

6 MDB-9 Staff Recreation


A INCOMER
1 No. 125A FP MCCB (25 KA) with E/f module & Core Balancing type CT (CBCT)
a)
complete.
B METERING & INDICATION
a) 1 Sets of R,Y,B phase indicating lamps
b) 1 Nos. (0-500V) Voltmeter with VSS with 3 nos. 2A SP MCB
c) 1 Nos. (0-125A) Ammeter with ASS with 3 nos. 125/5A CT's
C BUS-BAR
a) 1 Sets of 200A TPN Aluminium Bus Bar with colour coded PVC Sleeves
D OUTGOINGS
a) 5 Nos. 63A FP MCCB (16 KA)
b) 3 Nos. 32A DP MCB (10KA)
Supply of MDB-9 Staff Recreation as described above. Set 121000.00 1 121000.00
Receiving, fixing, testing & commissioning of MDB-9 Staff Recreation Set 2500.00 1 2500.00

7 MDB-10 Student Recreation


A INCOMER
Sub-Head-I : Preamble to BOQ for MV Panels
Item Quantity Amount
S.N. Description Unit Rate Remarks
code DSR NON DSR DSR NON DSR
1 No. 200A FP MCCB (25 KA) with E/f Module & Core Balancing type CT (CBCT)
a)
complete.
B METERING & INDICATION
a) 1 Set of R,Y,B phase indicating lamps
b) 1 No. (0-500V) Voltmeter with VSS with 3 nos. 2A SP MCB
c) 1 No. (0-200A) Ammeter with ASS with 3 nos. 200/5A CT's
C BUS-BAR
a) 1 Set of 300A TPN Aluminium Bus Bar with colour coded PVC Sleeves
D OUTGOINGS
a) 6 Nos. 63A FP MCCB (16 KA)
b) 4 Nos.40A FP MCB (10KA)
c) 2 Nos.32A DP MCB (10KA)
Supply of MDB-10 Student recreation as described above. Set 155000.00 1 155000.00
Receiving, fixing, testing & commissioning of MDB-10 Student recreation Set 2500.00 1 2500.00
RESIDENTIAL BLOCK
Sub-Head-I : Panels & Distribution boards (NS Items)

Design, Fabrication, Supply, Erection,Testing and commisioning of Powder coated


Main Distribution Panel fabricated out of 14 guage CRCA sheet steel in cubical,
compartmentallised free standing floor /wall mounted, dust and vermin proof, with
reinforcement of suitable size angle iron, channel, T -iron or flats as required. Cable
gland plates shall be provided on top as well as bottom of the panels. Panels shall
be treated with all anti-corrosive process before painting complete as per
specification & SLD. Panels shall be suitable for 415V, 3-Phase, Four wire, 50 Hz
supply complete with earth bus and lifting hooks as required in case of large
panels.Approval shall be taken for each panel before fabrication. (All hardwares like
nuts and bolts used shall be Galvanized and Zinc passivated) (Note: Contractor
can select the next higher fault rating of MCCB if it is not readily available, without
any extra cost, as the figure indicated within the bracket are required maximum
fault level of that panel)

1 Meter Panel(Type-I & type II)


INCOMER
1 No. 300A FP MCCB (35 KA) with E/f module & Core Balancing type CT (CBCT)
complete.
METERING & INDICATION
1 Sets of R,Y,B phase indicating lamps
1 Nos. (0-500V) Voltmeter with VSS with 3 nos. 2A SP MCB
1 Nos. (0-300A) Ammeter with ASS with 3 nos. 300/5A CT's
BUS-BAR
1 Sets of 400A TPN Aluminium Bus Bar with colour coded PVC Sleeves
OUTGOINGS
a) 36 No. 63A FP MCB with Three phase Dual type digital energy meter
b) 3 Nos. 40A TPN MCB (10 KA) C series
c) 3 No. 63A TPN MCB (10 KA)
d) Supply of Meter Panel described above. Sets 0.00 0 0.00
Receiving, fixing, testing & commissioning of above Metering Panel Sets 0.00 0 0.00

2 Meter Panel(Type-III )
INCOMER
1 No. 500A FP MCCB (35 KA) with E/f module & Core Balancing type CT (CBCT)
complete.
Sub-Head-I : Preamble to BOQ for MV Panels
Item Quantity Amount
S.N. Description Unit Rate Remarks
code DSR NON DSR DSR NON DSR
METERING & INDICATION
a) 1 Sets of R,Y,B phase indicating lamps
b) 1 Nos. (0-500V) Voltmeter with VSS with 3 nos. 2A SP MCB
c) 1 Nos. (0-500A) Ammeter with ASS with 3 nos. 500/5A CT's
2.2 BUS-BAR
1 Sets of 600A TPN Aluminium Bus Bar with colour coded PVC Sleeves

a) 36 No. 63A FP MCB with Three phase Dual type digital energy meter
b) 3 Nos. 40A TPN MCB (10 KA) C series
c) 3 No. 63A TPN MCB (10 KA)
d) Supply of Meter Panel described above. Sets 0.00 0 0.00
Receiving, fixing, testing & commissioning of above Metering Panel Sets 0.00 0 0.00

3 Meter Panel(Type-IV) )
A INCOMER
1 No. 400A FP MCCB (35 KA) with E/f module & Core Balancing type CT (CBCT)
complete.
b) METERING & INDICATION
a) 1 Sets of R,Y,B phase indicating lamps
b) 1 Nos. (0-500V) Voltmeter with VSS with 3 nos. 2A SP MCB
c) 1 Nos. (0-400A) Ammeter with ASS with 3 nos. 400/5A CT's
c) BUS-BAR
1 Sets of 500A TPN Aluminium Bus Bar with colour coded PVC Sleeves
OUTGOINGS
a) 28 No. 63A FP MCB with Three phase Dual type digital energy meter
b) 3 Nos. 40A TPN MCB (10 KA) C series
c) 3 No. 63A TPN MCB (10 KA)
d) Supply of Meter Panel described above. Sets 0.00 0 0.00
Receiving, fixing, testing & commissioning of above Metering Panel Sets 0.00 0 0.00

4 Meter Panel(Type-V & VI )


A INCOMER
1 No. 250A FP MCCB (35 KA) with E/f module & Core Balancing type CT (CBCT)
complete.
b) METERING & INDICATION
a) 1 Sets of R,Y,B phase indicating lamps
b) 1 Nos. (0-500V) Voltmeter with VSS with 3 nos. 2A SP MCB
c) 1 Nos. (0-500A) Ammeter with ASS with 3 nos. 500/5A CT's
c) BUS-BAR
1 Sets of 400A TPN Aluminium Bus Bar with colour coded PVC Sleeves
d) OUTGOINGS
a) 14 No. 63A FP MCB with Three phase Dual type digital energy meter
b) 3 Nos. 40A TPN MCB (10 KA) C series
c) 3 No. 63A TPN MCB (10 KA)
d) Supply of Meter Panel described above. Sets 0.00 0 0.00
Receiving, fixing, testing & commissioning of above Metering Panel Sets 0.00 0 0.00

Total Sub-Head-I : MV Panels 76714100.00


Sub-Head-I : Preamble to BOQ for MV Panels
Item Quantity Amount
S.N. Description Unit Rate Remarks
code DSR NON DSR DSR NON DSR
Sub-Head-II : Circuit Cum Point Wiring ( DSR Items)
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR
1.3
PVC insulated copper conductor single core cable in surface/ recessed steel
WGSTL
1 conduit with modular switch modular plate suitable GI box and earthing the point
MOD
with 1.5 sq.mm FR PVC insulated copper conductor single core cable etc.as
Group C
required.
1.3.1 Group A Point 392.00 700 274400
1.3.3 Group C Point 589.00 20750 12221750

Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR
1.10 PVC insulated copper conductor single core cable in surface/ recessed PVC
2 WGPVC conduit with modular switch modular plate suitable GI box and earthing the point
MOD with 1.5 sq.mm FR PVC insulated copper conductor single core cable etc.as
required.
1.10.1 Group A Point 293.00 13600 3984800
1.10.2 Group B Point 335.00 6712 2248520

Wiring for twin light point with 1.5 sq.mm FR PVC insulated copper conductor
1.4
single core cable in surface/ recessed steel conduit with 2 way modular switch
3 WGSTL Point 617.00 17276
modular plate suitable GI box and earthing the point with 1.5 sq.mm FR PVC
MODTC
insulated copper conductor single core cable etc.as required. 28

Wiring for twin light point with 1.5 sq.mm FR PVC insulated copper conductor
1.11
single core cable in surface/ recessed PVC conduit with 2 way modular switch
4 WGSTL Point 453.00 122310
modular plate suitable GI box and earthing the point with 1.5 sq.mm FR PVC
MODTC
insulated copper conductor single core cable etc.as required. 270

1.5 Wiring for power plug points with 2 x 4 sq.mm. FR PVC insulated, Cu. Conductor,
5 WGSTL single core cable in surface/ recessed steel conduit along with 1 No. 4sq.mm. FR Mtr. 136.00 4737832
PP2 PVC insulated copper conductor single core cable etc. as required. 34837

1.12 Wiring for power plug points with 2 x 4 sq.mm. FR PVC insulated, Cu. Conductor,
6 WGPVC single core cable in surface/ recessed PVC conduit along with 1 No. 4sq.mm. FR Mtr. 97.00 3074900
PP2 PVC insulated copper conductor single core cable etc. as required. 31700

Wiring for light plug points / power plug points with 4 x 4 sq.mm. FR PVC insulated,
1.6
Cu. Conductor, single core cable in surface/ recessed steel conduit along with 2
7 WGSTL Mtr. 191.00 8212427
Nos. 4sq.mm. FR PVC insulated copper conductor single core cable etc. as
PP4
required. 42997

Wiring for light plug points / power plug points with 4 x 4 sq.mm. FR PVC insulated,
1.13
Cu. Conductor, single core cable in surface/ recessed PVC conduit along with 2
8 WGPVC Mtr. 149.00 1624100
Nos. 4sq.mm. FR PVC insulated copper conductor single core cable etc. as
PP4
required. 10900

1.7 Wiring for circuit/ submain wiring alongwith earth wire with the follwing size of PVC
9 WGSTL Insulated copper conductor single core cable in surface/ recess Steel conduit as
SB required.
a 1.7.1 2x 1.5 sqmm+ 1x 1.5 sqmm earth wire Mtr. 109 71250 7766250
b 1.7.2 2x 2.5 sqmm+ 1x 2.5 sqmm earth wire for outlet on UPS Mtr. 120 22800 2736000
c 1.7.3 2x 4 sqmm+ 1x 4 sqmm earth wire Mtr. 135 5000 675000
d 1.7.4 2x 6 sqmm+ 1x 6 sqmm earth wire Mtr. 169 5000 845000
Sub-Head-I : Preamble to BOQ for MV Panels
Item Quantity Amount
S.N. Description Unit Rate Remarks
code DSR NON DSR DSR NON DSR
e 1.7.5 2x 10 sqmm+ 1x 10 sqmm earth wire for 40A Industrial socket Mtr. 213 5500 1171500
f 1.7.8 4x 2.5 sqmm+ 2x 2.5 sqmm earth wire for outlet on UPS Mtr. 160 11820 1891200
g 1.7.9 4x 4 sqmm+ 2x 4 sqmm earth wire Mtr. 190 2500 475000
h 1.7.10 4x 6 sqmm+ 2x 6 sqmm earth wire Mtr. 258 4800 1238400
i 1.7.11 4x 10 sqmm+ 2x 10 sqmm earth wire for 40A Industrial socket Mtr. 367 1500 550500
j 1.7.12 4x 16 sqmm+ 2x 16 sqmm earth wire for submain wiring Mtr. 590 150 88500

1.14 Wiring for circuit/ submain wiring alongwith earth wire with the follwing size of PVC
10 WGPVC Insulated copper conductor single core cable in surface/ recess PVC conduit as
SB required.
a 1.14.1 2x 1.5 sqmm+ 1x 1.5 sqmm earth wire Mtr. 71.00 57215 4062265
b 1.14.2 2x 2.5 sqmm+ 1x 2.5 sqmm earth wire for outlet on UPS Mtr.
c 1.14.8 4x 2.5 sqmm+ 2x 2.5 sqmm earth wire for outlet on UPS Mtr.
d 1.14.4 2x 6 sqmm+ 1x 6 sqmm earth wire Mtr. 127.00 15500 1968500
e 1.14.11 4x 10 sqmm+ 2x 10 sqmm earth wire Mtr. 294.00 500 147000
f 1.14.12 4x 16 sqmm+ 2x 16 sqmm earth wire Mtr. 487.00

1.17 Supply & drawing of following sizes of FR PVC insulated copper conductor, single
11
WGEC core cable in the existing surface/ recessed steel/ PVC conduit as required.
a 1.17.1 1 x 1.5 sq.mm.for dedicated earth wire for outlet on UPS Mtr. 19.00 19845 377055
b 1.17.2 2 x 1.5 sq.mm.for dedicated earth wire for outlet on UPS Mtr. 25.00 11970 299250
c 1.17.3 3 x 1.5 sq.mm. Mtr. 32.00 76945 2462240
d 1.17.11 2 x 2.5 sq.mm.for dedicated earth wire for Power outlet on UPS Mtr. 32.00 4000 128000

Supplying and fixing suitable size GI box with modular plate and cover in front on
1.31
surface or in recess including providing and fixing 3 pin 5/6 Amp modular socket
12 LPACC Each 160.00 1710 273600
outlet and 5/6 A modular type switch, connections painting etc. as reqd, for Light
MOD
plug point.(For light plugs to be used in non residential buildings.)

Supplying and fixing suitable size GI box with modular plate and cover in front on
1.32
surface or in recess including providing and fixing 6 pin 15/16 & 5/6 Amp modular
13 PPACC Each 214.00 1947400
socket outlet and 15/16 A modular type switch, connections painting etc. as reqd.
MOD
(for power sockets) 9100

1.24.1
Supplying and fixing of 5/6 Amps switch on the existing modular plate & switch box
14 MODS Each 46.00 413126
including connections but excluding modular plate etc. as reqd.
WEB 8981

1.24.4
Supplying and fixing of 3 pin 5/6 Amps socket outlet on the existing modular plate &
15 MODS Each 64.00 482624
switch box including connections but excluding modular plate etc. as reqd.
WEB 7541

1.24.3
Supplying and fixing of 15/16 Amps switch on the existing modular plate & switch
16 MODS Each 67.00 118925
box including connections but excluding modular plate etc. as reqd.
WEB 1775

1.24.5
Supplying and fixing of 6 pin 15/16 Amps Socket on the existing modular plate &
17 MODS Each 101.00 294011
switch box including connections but excluding modular plate etc. as reqd.
WEB 2911
Sub-Head-I : Preamble to BOQ for MV Panels
Item Quantity Amount
S.N. Description Unit Rate Remarks
code DSR NON DSR DSR NON DSR
1.26
Supplying and fixing of modular Blanking plate on the existing modular plate &
18 MODBP Each 20.00 129340
switch box including connections but excluding modular plate etc. as reqd.
EB 6467

1.25 Supplying and fixing of Stepped type electronic fan regulator on the existing
19 MODFR modular plate & switch box including connections but excluding modular plate etc. Each 247.00 759525
EB as reqd. 3075

1.27 Supply and fixing of following size/ modules, GI box along with modular base &
20 MODGI cover plate for modular switch/ regulator in recess, including connection as
BXCP required.
a 1.27.1 1or 2 module (75mmx 75mm) Each 88.00 2046 180048
b 1.27.2 4 module (75mmx 75mm) Each 113.00 4532 512116
c 1.27.3 6 module (200mmx 75mm) Each 153.00 1461 223533

1.33 Supplying & fixing of 3 pin, 5 amp ceiling rose on the existing junction box/ wooden
21 Each 19.00 11286
CREB block including connection as required, for Exit signage. 594

Supply & fixing of Call bell/ Buzzer suitable for A.C. single phase, 230 volts
22
1.38 CALLBELL Each 26.00 12688
complete as required 488

Supplying and fixing 20 Amps. 240 Volts SPN industrial type socket outlet, with 2
2.62 pole and earth metal enclosed plug top along with 20 A `C' series SP MCB in sheet
23 MCBDP steel enclosure, on surface or in recess with chained metal cover for the socket Each 520.00 494000
SOC20 outlet complete with connections testing and commissioning etc. as reqd, for A.C.
outlet 950

Sub-Head-II : Circuit Cum Point Wiring (Non Schedule Items)


Providing & fixing, testing & commssioning of 20A Moulded Plastic 3 pin Socket
24 NS outlet and Top with 20A SP MCB in a suitable size of moulded PVC box (IP44), Nos. 1260.00 56700
including earthing of third pin of the socket . 45

Providing & fixing, testing & commssioning of 32A Moulded Plastic 3 pin Socket
25 NS outlet and Top with 32A SP MCB in a suitable size of moulded PVC box (IP44), Nos. 1610.00 16100
including earthing of third pin of the socket . 10

Providing & Fixing of 20A Moulded Plastic 5 pin Socket outlet and Top with 20A
26 NS TPN MCB in a suitable size of moulded PVC box (IP44), including earthing of third Nos.
pin of the socket.

Providing & Fixing of 32A Moulded Plastic 5 pin Socket outlet and Top with 32A
27 NS TPN MCB in a suitable size of moulded PVC box (IP44), including earthing of third Nos. 2900.00 63800
pin of the socket. 22

Providing & Fixing of 40A Moulded Plastic 5 pin Socket outlet and Top with 40A
28 NS TPN MCB in a suitable size of moulded PVC box (IP44), including earthing of third Nos. 7025.00 21075
pin of the socket. (Conduit & wires are paid elsewhere in BOQ) 3

Supply, fixing, testing & commissioning of 20A, 250V AC Key fob switch with Key
29 NS Nos. 935.00 433840
fob complete. 464
Sub-Head-I : Preamble to BOQ for MV Panels
Item Quantity Amount
S.N. Description Unit Rate Remarks
code DSR NON DSR DSR NON DSR
Supply of Bedhead side console/panel in moulded plastic box of suitable size and
suitable nos. of knockout holes for conduit entry, complete with cutout on console
30 NS suitable for fixing of follwing modular sockets, switches & gas outlets but excluding
of socket & outlets: (Note: The contractor shall submit sample and take written
approval from Project Manager before procuring this item)
30.1 Bedhead side panel Type-1(for Casualty)
1 no. - 16A, 6 pin switched socket for UPS Power.
1 Set. -2 no. 5 pin 6Asoc. with 1 no. switch on Raw power
1 no. - 6A Switch for light.
1 no. - Bell Push with reset button for Nurse Call Station.
3nos.Outlets for Medical Gases
Bedhead side panel Type-1 as described above: Sets 0.00 0

30.2 Bedhead side panel Type-2(for ICU & Pre/Post OP)


4 nos. - 16A, 6 pin switched socket on UPS power
3 Sets -2 nos. 6A, 5 pin socket controlled by 1 no.6A switch on UPS power
1 no. - 6A Switch for light.
3nos.Outlets for Medical Gases
Bedhead side panel Type-2 as described above: Sets 0.00 0

30.3 Bedhead side panel Type-3(for NICU )


2 nos. - 16A, 6 pin switched socket on UPS power
1 Set. -2 no. 5 pin 6Asoc. with 1 no. switch on Raw power
1 no. - 6A Switch for light.
3nos.Outlets for Medical Gases
Bedhead side panel Type-3 as described above: Sets 0.00 0

30.4 Bedhead side panel Type-4 (General wards)


1 no. - 16A, 6 pin switched socket on Raw power
1 Set. -2 no. 5 pin 6Asoc. with 1 no. switch on Raw power
1 no. - Bell Push with reset button for Nurse Call Station.
2 nos.Outlets for Medical Gases
Bedhead side panel Type-4 as described above: Sets 0.00 0

Total of Sub-Head - II Circuit Cum Point Wiring 591515 69252197

Sub-Head -III : L.T Cables ( DSR Items)


1 1.21 Supplying and fixing of following sizes of steel conduit along with accessories in
MSCON surface / recess including painting in case of surface conduit,or cutting the wall and
making good the same in case of receeesed conduit as required
a) 1.21.3 32mm Dia. Mtrs.

2 1.7 Wiring for circuit/ submain wiring alongwith earth wire with the follwing size of FR
PVC Insulated copper conductor, single core cable in surface/ recess Steel conduit
as required.
a) 1.7.3 2 x 4 sq.mm. + 1 x 4 sq.mm. (E) for Submain wiring. Mtrs. 135.00 85 11475
b) 1.7.4 2 x 6 sq.mm. + 1 x 6 sq.mm. (E) for Submain wiring. Mtrs. 0.00 0
c) 1.7.5 2 x 10 sq.mm. + 1 x 10 sq.mm. (E) for Submain wiring. Mtrs. 0.00 0
d) 1.7.10 4 x 6 sq.mm. + 2 x 6.0 sq.mm. (E) for Submain wiring. Mtrs. 0.00 0
e) 1.7.11 4 x10 sq.mm. + 2 x10.0 sq.mm. (E) for Submain wiring. Mtrs. 0.00 0
f) 1.7.12 4 x16 sq.mm. + 2 x16.0 sq.mm. (E) for Submain wiring. Mtrs. 0.00 0
Sub-Head-I : Preamble to BOQ for MV Panels
Item Quantity Amount
S.N. Description Unit Rate Remarks
code DSR NON DSR DSR NON DSR
3 1.14 Wiring for circuit/ submain wiring alongwith earth wire with the follwing size of FR
WGPVC PVC Insulated copper conductor, single core cable in surface/ recess PVC conduit
SB as required.
a) 1.14.3 2 x 4 sq.mm. + 1 x 4 sq.mm. (E) for Submain wiring. Mtrs. 97.00 2700 261900
b) 1.14.4 2 x 6 sq.mm. + 1 x 6 sq.mm. (E) for Submain wiring. Mtrs. 127.00 3200 406400
c) 1.14.5 2 x 10 sq.mm. + 1 x 10 sq.mm. (E) for Submain wiring. Mtrs. 171.00 2500 427500
d) 1.14.9 4 x 4 sq.mm. + 2 x 4 sq.mm. (E) for Submain wiring. Mtrs. 148.00 4700 695600
e) 1.14.10 4 x 6 sq.mm. + 2 x 6.0 sq.mm. (E) for Submain wiring. Mtrs. 207.00 5000 1035000
f) 1.14.11 4 x10 sq.mm. + 2 x10.0 sq.mm. (E) for Submain wiring. Mtrs. 294.00 150 44100
g) 1.14.12 4 x16 sq.mm. + 2 x16.0 sq.mm. (E) for Submain wiring. Mtrs. 487.00 150 73050

4 1.22.9 Supply & Fixing surface/ recessed mounted 16 SWG CRCA sheet steel fabricated
MB 200mm x 250mm x 60mm deep powder coated Junction box with phenolic
laminated cover, with suitable nos. of knockout holes for 32mm/ 25mm dia conduit, 8494
in Electrical Shaft for coupling of MS cond. to PVC cond. Sets 137.00 62

5 1.22.7 Supply & Fixing surface/ recessed mounted 16 SWG CRCA sheet steel fabricated
MB 200mm x 150mm x 60mm deep powder coated Junction box with phenolic
laminated cover, with suitable nos. of knockout holes for 32mm/ 25mm dia conduit, 4410
in Electrical Shaft for coupling of MS cond. to PVC cond. Sets 105.00 42

Part- Laying of one number PVC insulated & PVC sheathed/ XLPE Power cable of 1.1
II,Extern KV grade of size not exceeding 25 sq.mm direct in ground including excavation,
6 al 1.1 sand cushioning, protective covering and refilling the trench etc. as required. Meter 313650
MVCBG
R25 85.00 3690

Part- Laying of one number PVC insulated & PVC sheathed/ XLPE Power cable of 1.1
II,Extern KV grade of size exceeding 120 sq.mm but not exceeding 400 sq.mm. direct in
7 al 1.3 ground including excavation, sand cushioning, protective covering and refilling the Meter 339500
MVCBG trench etc. as required.
R400 97.00 3500

Part- Laying of one number PVC insulated & PVC sheathed/ XLPE Power cable of 1.1
II,Extern KV grade of size not exceeding 25 sq.mm. direct in ground in the same trench in
8 al 1.4 onr tier horizental formation including excavation, sand cushioning, protective Meter 45600
MVCBG covering and refilling the trench etc. as required.
RT25 57.00 800

Part- Laying of one number PVC insulated & PVC sheathed/ XLPE Power cable of 1.1
II,Extern KV grade of size exceeding 25 sq.mm but not exceeding 120sq.mm. direct in
9 al 1.5 ground in the same trench in onr tier horizental formation including excavation, Meter 228000
MVCBG sand cushioning, protective covering and refilling the trench etc. as required.
RT120 60.00 3800

Part- Laying of one number PVC insulated & PVC sheathed/ XLPE Power cable of 1.1
II,Extern KV grade of size exceeding 120 sq.mm but not exceeding 400 sq.mm. direct in
10 al 1.6 ground in the same trench in onr tier horizental formation including excavation, Meter 651420
MVCBG sand cushioning, protective covering and refilling the trench etc. as required.
RT400 63.00 10340
0
Sub-Head-I : Preamble to BOQ for MV Panels
Item Quantity Amount
S.N. Description Unit Rate Remarks
code DSR NON DSR DSR NON DSR
11 Part- Laying & fixing of one number PVC insulated & PVC sheathed/ XLPE Aluminium
II,Extern conductor cable of 1.1 KV grade of size not exceeding 25sq.mm on surface as
al 1.11 required.
MVCBS 1111970
UR25
Mtr. 31.00 35870
0
12 Part- Laying & fixing of one number PVC insulated & PVC sheathed/ XLPE Aluminium
II,Extern conductor cable of 1.1 KV grade of size exceeding 25sq.mm but not exceeding 120
al 1.12 sq.mm on surface as required.
MVCBS 249570
UR120
Mtr. 59.00 4230

13 Part- Laying & fixing of one number PVC insulated & PVC sheathed/ XLPE Aluminium
II,Extern conductor cable of 1.1 KV grade of size exceeding 120 sq.mm but not exceeding
al 1.13 400 sq.mm on surface as required.
MVCBS 962580
UR400
Mtr. 61.00 15780

14 PartII,Ex Supplying & making of end terminations with brass compression gland and Al. lugs
ternal for following sizes of PVC insulated and PVC sheathed/ XLPE Al. conductor cable
4.1.32 of 1.1 KV grade as required.
MVET
a) 4.1.1 2 x 6 sq.mm. Each 69.00 542 37398
b) 4.1.2 2 x 10 sq.mm. Each 76.00 44 3344
c) 4.1.3 2 x 16 sq.mm. Each 0.00 0
d) 4.1.8 3 x 16 sq.mm. Each 120.00 60 7200
e) 4.1.7 3 x 10 sq.mm. Each 102.00 126 12852
f) 4.1.11 3 x 50 sq.mm. Each 0.00 0
f.1) 4.1.12 3 x 70 sq.mm. Each 169.00 28 4732
g) 4.1.13 3 x 95 sq.mm. Each 0.00 0
h.1) 4.1.9 3 x 25 sq.mm. Each 128.00 12 1536
h) 4.1.20 3.5 x 25 sq.mm. Each 106.00 38 4028
i) 4.1.21 3.5 x 35 sq.mm. Each 137.00 14 1918
j) 4.1.22 3.5 x 50 sq.mm. Each 146.00 12 1752
k) 4.1.23 3.5 x 70 sq.mm. Each 168.00 30 5040
l) 4.1.24 3.5 x 95 sq.mm. Each 197.00 46 9062
m) 4.1.25 3.5 x 120 sq.mm. Each 199.00 26 5174
n) 4.1.26 3.5 x 150 sq.mm. Each 278.00 30 8340
o) 4.1.27 3.5 x 185 sq.mm. Each 319.00 104 33176
p) 4.1.29 3.5 x 240 sq.mm. Each 381.00 142 54102
q) 4.1.30 3.5 x 300 sq.mm. Each 508.00 220 111760
r) 4.1.36 4 x 50 sq.mm. Each 0.00 0
s) 4.1.35 4 x 35 sq.mm. Each 157.00 14 2198
t) 4.1.33 4 x 16 sq.mm. Each 196.00 338 66248
u) 4.1.32 4 x 10 sq.mm. Each 104.00 410 42640
v) 4.1.34 4 x 25 sq.mm. Each 137.00 68 9316
Sub-Head-I : Preamble to BOQ for MV Panels
Item Quantity Amount
S.N. Description Unit Rate Remarks
code DSR NON DSR DSR NON DSR
15 PartII,Ex Fabricating and Installation of following size of perforated M.S. cable Trays
ternal including horizontal & vertical bends, reducers, tees, cross members, and other
3.1 accessories as required and duly suspended from the ceiling with MS suspenders
CBTR and including painting with powder coating etc. as required.
a) 3.1.2 150 mm width x 50 mm depth x 1.6 mm thickness Metre 335.00 2655 889425
b) 3.1.4 300 mm width x 50 mm depth x 1.6 mm thickness Metre 524.00 2225 1165900
c) 3.1.7 450 mm width x 50 mm depth x 2.0 mm thickness Metre 775.00 860.48 666872
d) 3.1.7 600 mm width x 50 mm depth x 2.0 mm thickness Metre 974.00 28.75 28002.5
e) 3.1.16 900 mm width x 75 mm depth x 2.0 mm thickness Metre 1310.00 1210 1585100

16 DSR for Constructing brick masonary Mayholes in cement mortar (cement: coarse sand-1:4)
Drainag R.C.C. top slab with ( cement: coarse sand: stone aggregate-1:2:4), foundation
e works concrete ( cement: sand; stone aggregate-1:4:8 ) inside plastering 12 mm thick with
cement mortar (1:3) finshed with floating coat of neat cement making cannels in
cement concrete (1:2:4) as per standard design

19.7.1.1 Inside 900mmx800mm and 750mm deep with F.P.S. brickss with class
+ designation-75, including pre-cast RCC manhole cover & frame of rectangular
19.8.1.1 shape of 600mmx 450mm internal dimension
-
a) 19.18.1 6055.70 30 181671
+
19.19.1.
1
Nos.

19.7.2.1 Inside 1200mmx900mm and 900mm deep with F.P.S. brickss with class
- designation-75, including pre-cast RCC manhole cover & frame of rectangular
19.18.1 shape of 600mmx 450mm internal dimension
b) + 11758.00 45 529110
19.19.1.
1
Nos.

DSR for Supplying and laying NP2 class RCC hume pipe with collars jointed with stiff
Earth mixture of cement mortar in the proportion of 1:2 as required, complete with
17 works- excavation of suitable size of trenches and making good of the same.
19.6
19.6.2 +
a) 2.13.1.2 150 mm dia Mtrs. 450.95 120 54114

19.6.3 +
b) 2.13.1.2 250 mm dia Mtrs. 506.30 455 230366.5

Total of Sub-Head - III carried to summary sheet (DSR Item)

Sub-Head-III: L.T Cables (Non- Schedule Items)


18 NS Supply of following sizes of XLPE/ PVC insulated Aluminum/ Copper conductor
strip/ wire Armoured, overall PVC sheathed 1.1 KV grade cables conforming to
relevant IS code and technical specifications.
18.1 XLPE insulated Al. Ar.Cable
a) 3.5C x 300 sq.mm. RM 2046.00 17112 35011152
Sub-Head-I : Preamble to BOQ for MV Panels
Item Quantity Amount
S.N. Description Unit Rate Remarks
code DSR NON DSR DSR NON DSR
b) 3.5C x 240 sq.mm. RM 1671.00 7150 11947650
c) 3.5C x 185 sq.mm. RM 1306.00 4115 5374190
d) 3.5C x 150 sq.mm. RM 1053.00 495 521235
e) 3.5C x 120 sq.mm. RM 910.00 1350 1228500
f) 3.5C x 95 sq.mm. RM 0.00 0
f.1) 3.5C x 95 sq.mm. RM 720.00 1270 914400
g) 3.5C x 70 sq.mm. RM 585.00 1610 941850
h) 3.5C x 50 sq.mm. RM 457.00 605 276485
i) 3.5C x 35 sq.mm. RM 346.00 815 281990
j) 3.5C x 25 sq.mm. RM 294.00 350 102900
k) 4C x 35 sq.mm. RM 385.00 60 23100
l) 4C x 25 sq.mm. RM 310.00 490 151900
m) 4C x 16 sq.mm. RM 250.00 12050 3012500
n) 4C x 10 sq.mm. RM 199.00 11700 2328300
o) 4C x 6 sq.mm. RM 0.00 0
o.1) 4C x 6 sq.mm. RM 193.00 6580 1269940
p) 4C x 4 sq.mm. RM 165.00 350 57750
q) 3C x 95 sq.mm. RM 0.00 0
r) 3C x 70 sq.mm. RM
s) 3C x 50 sq.mm. RM 0.00 0
t) 3C x 35 sq.mm. RM 0.00 0
u) 3C x 25 sq.mm. RM 247.00 300 74100
v) 3C x 16 sq.mm. RM 0.00 0
v.1) 3C x 16 sq.mm. RM 200.00 1230 246000
w) 3C x 10 sq.mm. RM 0.00 0
w) 3C x 10 sq.mm. RM 180.00 2830 509400
x) 3C x 6 sq.mm. RM 174.00 3050 530700
y) 3C x 4 sq.mm. RM 135.00 350 47250
z) 2C x 16 sq.mm. RM 0.00 0
aa) 2C x 10 sq.mm. RM 163.00 2020 329260
ab) 2C x 6 sq.mm. RM 151.00 4010 605510
ac) 2C x 4 sq.mm. RM 80.00 50 4000
18.2 PVC insulated Cu. Ar. Cables
a) 4C x 70 sq.mm. RM 4298.00 100 429800
b) 4C x 50 sq.mm. RM 3118.00 150 467700
c) 4C x 35 sq.mm. RM 2305.00 250 576250
d) 4C x 25 sq.mm. RM 1694.00 150 254100
e) 4C x 4 Sq.mm. RM 324.00 520 168480
f) 2C x 4 Sq.mm. RM 202.00 410 82820
g) 2C x 2.5 Sq.mm. RM 157.00 380 59660
h) 7C x 2.5 Sq.mm. RM 370.00 320 118400
i) 12C x 2.5 Sq.mm. RM 562.00 380 213560

19 NS Supply and making End termination with brass Single/ Double compression gland
including providing and crimping of aluminum/copper solderless lugs/ferrules for
XLPE/PVC insulated armoured power aluminum/copper conductor cables 1.1 KV
grade of following sizes:
19.1 Single Compression Gland for Al. Ar.Cable
a) 4 x 4 sq.mm. Each 107.00 14 1498
b) 4 x 6 sq.mm. Each 107.00 502 53714
c) 3 x 6 sq.mm. Each 0.00 0
19.2 Single Compression Gland for Cu. Cable
a) 4C x 70 sq.mm. Each 595.00 2 1190
b) 4C x 50 sq.mm. Each 385.00 20 7700
Sub-Head-I : Preamble to BOQ for MV Panels
Item Quantity Amount
S.N. Description Unit Rate Remarks
code DSR NON DSR DSR NON DSR
c) 4C x 35 sq.mm. Each 285.00 28 7980
d) 4C x 25 sq.mm. Each 215.00 10 2150
e) 4C x 4 Sq.mm. Each 115.00 16 1840
f) 2C x 4 Sq.mm. Each 98.00 12 1176
g) 7C x 2.5 sq.mm. Sets 143.00 16 2288
h) 12C x 2.5 sq.mm. Sets 216.00 32 6912
i) 2C/ 4C x 2.5/ 4.0 sq.mm. Sets 103.00 56 5768

Total Sub-Head -III : L.T Cables 12622596 68253048

SR-2007 Sub-Head - IV : Conduits and Wiring for Tel., MATV & Nurse Call System ( DSR Item)
11.21 PVCCONSupply & fixing of following sizes of PVC conduit along with accessories in surface /
recessed including cutting the wall & making good the same in case of recessed
conduit as required, for conduiting in Flat and from flat to LV shaft
a) 1.21.1 20 mm dia. Mtrs. 41.00 5500.00 225500.00
b) 1.21.2 25 mm dia. Mtrs. 47.00 38800.00 1823600.00
c) 1.21.3 32 mm dia. Mtrs. 56.00 250.00 14000.00

2 1.20 Supplying and fixing of following sizes of steel conduit along with accessories in
STLCO surface / recess including painting in case of surface conduit,or cutting the wall and
N making good the same in case of receeesed conduit as required

a) 1.20.1 20 mm dia. Mtrs. 77.00 23050.00 1774850.00


b) 1.20.2 25 mm dia. Mtrs. 86.00 43300.00 3723800.00
c) 1.20.3 32 mm dia. Mtrs. 105.00 2200.00 231000.00
d) 1.20.4 40 mm dia. Mtrs. 0.00 0.00 0.00

3 1.22.6 Supply & Fixing surface/ recessed mounted 16 SWG CRCA sheet steel fabricated
MB 200mm x 125mm x 60mm deep powder coated Junction box with phenolic
laminated cover, with suitable nos. of knockout holes for 32mm/ 25mm dia conduit, 940
in LV Shaft for coupling of MS cond. to PVC cond. Sets 97.00 91180.00

4 1.19 Supply and drawing of Co-axial TV cable RG-6 grade, 0.7mm solid Cu. Conductor
TVWGE PE insulated, shielded with fine tinned Cu. Braid & protected with PVC sheath in 27960
C exisiting surface / recessed steel/ PVC conduit as reqd. Mtrs. 23.00 643080.00

5 1.18.3 Supplying, drawing,of 4 pair 0.5sq.mm. FR PVC cable insulated Cu. Conductor Un
TLWGE ar. Tel. cable in existing surface/ recessed steel/ PVC conduit as reqd. 250
C Mtrs. 21.00 5250.00

6 1.18.1 Supplying, drawing,of 4 pair 0.5sq.mm. FR PVC cable insulated Cu. Conductor Un
TLWGE ar. Tel. cable in existing surface/ recessed steel/ PVC conduit as reqd. 0
C Mtrs. 0.00 0.00

7 1.24.6 Supplying and fixing of modular Telephone socket outlet on the existing Modular
MODS plate & switch including connection but excluding modular plate etc. as required. 2725
WEB Each 61.00 166225.00
Sub-Head-I : Preamble to BOQ for MV Panels
Item Quantity Amount
S.N. Description Unit Rate Remarks
code DSR NON DSR DSR NON DSR
8 1.24.7 Supplying and fixing of modular TV antenna socket outlet on the existing Modular
MODS plate & switch including connection but excluding modular plate etc. as required. 1642
WEB Each 60.00 98520.00

9 1.26 Supplying and fixing of modular Blanking Plate on the existing Modular plate &
MODBP switch including connection but excluding modular plate etc. as required.
EB Each 0.00 0.00

10 1.27 Supply and fixing of following size/ modules, GI box along with modular base &
MODGI cover plate for modular switch/ regulator in recess, including connection as
BXCP required.
a) 1.27.1 1or 2 module (75mmx 75mm) Each 88.00 4411 388168.00

11 DSR for Excavating Trenches of required width for Pipes / cables etc. in ordinary rock
Earth terrain including excavation for scokets, depth upto 1.5 mtr. Including getting out
works- the excavated materials, returning of the soilas required in layers, not exceeding 20 2000
2.13.1.1 cms in depth including consolidating each deposited layers by ramming, watering
etc. and disposal of surplus soil as required. Mtrs. 100.20 200400.00

Total of Sub-Head - IV carried to summary sheet (DSR Item)

Sub-Head - IV : Conduits and Wiring for Telephones, MATV System (Non Schedule Items)
12 Supplying and laying PVC pipe (heavy duty-6Kg Pr. class) under the road
crossings, including making of joints complete with excavation of suitable size of
trenches, refilling & removal of surplus soil.
a) 125 mm dia pipe RM. 550.00 210 115500
b) 80 mm dia pipe RM. 400.00 100 40000

13 NS Supply, installation, testing and commissioning of following krone type tag blocks
enclosed in MS enclosure of suitable size with lockable cover.
a 1000 pair Tag block No 46900.00 1 46900
b 800 pair Tag block No 40100.00 1 40100
c 400 pair Tag block No 19800.00 1 19800
d 300 pair Tag block No 14600.00 2 29200
e 250 pair Tag block No 12500.00 4 50000
f 200 pair Tag block No 9465.00 8 75720
g 160 pair Tag block No 7986.00 8 63888
h 150 pair Tag block No 7600.00 2 15200
i 100 pair Tag block No 5200.00 12 62400
j 80 pair Tag block No 4040.00 1 4040
k 60 pair Tag block No 3075.00 3 9225
l 50 pair Tag block No 2700.00 7 18900
m 40 pair Tag block No 2200.00 3 6600
n 20 pair Tag block No 1230.00 6 7380
o 10 pair Tag block No 0.00
o.1 10 pair Tag block No 738.00 7 5166

14 NS Supply, laying, testing and commissioning of following size of 0.61mm dia copper
conductor multi pair Armoured telephone cable as per suitable for indoor telephone
wiring conforming for ITD S/WS - 113 C and S/WS - 114 (actual qty. may vary as
per site) in existing conduit/ trench/ tray.
a 5 pair Ar. Cable RM 85.00 690 58650
b 10 pair Ar.cable RM 125.00 2690 336250
Sub-Head-I : Preamble to BOQ for MV Panels
Item Quantity Amount
S.N. Description Unit Rate Remarks
code DSR NON DSR DSR NON DSR
d 20 pair Ar. Cable RM 195.00 2000 390000
d 25 pair Ar.cable RM 225.00 740 166500
e 40 pair Ar.cable RM 310.00 150 46500
f 50 pairs Ar.cable RM 390.00 1810 705900
g 60 pairs Ar.cable RM 450.00 20 9000
h 100 pairs Ar. cable RM 710.00 6490 4607900
f) 120 pair Tag block Set 0.00 0 0
g) 60 pair Tag block Sets 0.00 0 0

15 NS Supplying, drawing, connecting & testing of 4 pair CAT-5(E) wire for Data Outlet in
94300 2357500
existing conduit RM 25.00

16 NS Supplying, drawing, connecting & testing of 4 pair CAT-6 (E) wire for Data Outlet in
46740 1635900
existing conduit RM 35.00

17 NS Supply, fixing, testing & commisssioning of Modular RJ-45 with data outlet socket
1280 595200
with grid & cover plate in suitable size of 16 SWG GI box. Nos 465.00

18 NS
Supply of Line Amplifiers for TV signal Booster from 70db to 110db.
0 0
(Note:contractor shall submit the brochure for approval of the item.)(Optional Item)
Nos. 0.00

19 NS Recieving, installation, testing and commissioning of Line Amplifiers. Nos. 0.00 0 0

20 NS Supply, erection, testing and commissioning of splitter/ Tap-off terminals for Co-
axial cables in suitable size of G.I. Boxes with hinged lockable cover complete.
a NS Two way Splitter(S2) Nos. 200.00 38 7600
b NS 3 way splitter Nos 300.00 7 2100
c NS 4 way splitter Nos 300.00 111 33300
d NS 1 way Tap-off Box. Nos. 150.00 129 19350
e NS 2 way Tap-off Box. Nos. 200.00 63 12600
f NS 3 way Tap-off box Nos 250.00 30 7500
g NS 4 way Tap-off box Nos 275.00 42 11550

21 NS Supply, laying and connecting of RG11 Co-axial TV cable as per specifications in


9852 541860
the existing conduit / raceways trays etc. RM 55.00

22 NS Receiving, fixing, effecting proper connection & testing of following bedside panel
( to be mounted on the bedhead side of patients' bed) complete with cutting of
chases & making good of the same and providing of all necessary hardware as
required for fixing.
a Bedside panel Type-1 (Casuality) Sets 150.00 35 5250
b Bedside panel Type-2 (ICU) Sets 250.00 148 37000
c Bedside panel Type-3 (NICU) Sets 150.00 32 4800
d Bedside panel Type-4 (General Ward) Sets 150.00 634 95100

23 NS Providing & laying of 65 mm dia.medium class GI pipe including all fixing


accessories, concealed or exposed as called for including cutting of chases and 420 128100
making good of the same. RM 305.00

24 NS Supplying and laying PVC pipe (heavy duty-6Kg Pr. class) under the road
crossings, including making of joints complete with excavation of suitable size of
trenches, refilling & removal of surplus soil.
Sub-Head-I : Preamble to BOQ for MV Panels
Item Quantity Amount
S.N. Description Unit Rate Remarks
code DSR NON DSR DSR NON DSR
a) 125 mm dia pipe RM. 0.00 0 0
b) 80 mm dia pipe RM. 0.00 0 0
Total Sub-Head - IV : Conduits and Wiring for Tel., MATV & Nurse Call System 9385573 12425429

SR-2007Sub-Head-V: Fixing of Fan & Light Fixtures (DSR Items)


1 1.41 Installation, testing & commissioning of pre-wired, fluorescent fitting / compact
ITCFFS fluoroscent fitting of all type, complete with all accessories & tubes etc. directly on
UR ceiling / wall, including connection with 1.5 sq.mm. FRLS PVC insulated, copper 43.00 19856 853,808.00
condutor, single core cable and earthing etc. as required. Each

21.45 ITCCFFC
Installation, testing & commissioning of ceiling fan including wiring the down rods
of standard length (upto 30 cm) with 1.5 sq.mm FRLS PVC insulated, copper
conductor, single core cable, including providing and fixing phenolic laminated 68.00 3075 209,100.00
sheet cover on the fan box etc. as reqd. Each

3.1 1.52 Installation of Exhaust fan upto 450mm sweep in the existing opening , including
ITCEF4 making the hole to suit the size of the above fan, making good the damage 223.00 1816 404,968.00
50 connection, testing commissioning etc. as required. Each
3.2 1.54
LOUSH Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all 65.00 1816 118,040.00
EF sizes.
Each

Total of Sub-Head - V carried to summary sheet (DSR Item)

Sub-Head-V: Fixing of Fan & Light Fixtures (Non-Schedule Items)


Receiving, storing, assembling, installation, testing & commissioning of following
pre-wired light fixtures including providing of all necessary hardwares like chian
suspenders, anchor bolts, nuts & bolts etc., as required for fixing, Including
connection with 1.5 sq.mm FR PVC insulated, Cu. Conductor single core cable &
earthing etc. as reqd.

4 NS All type of Recessed mounted Flourescent fitting in false ceiling Each 100.00 129 12900

5 NS All type of Recessed mounted CFL fitting in false ceiling Each 75.00 16543 1240725

6 NS Illuminated Double faced 8W CFL exit sign with batteries and battery charger
392 39200
complete. Each 100.00

7 NS All type of Flood Light & Medium bay luminiare & Chandaliare complete with control
gear including providing and grouting of mounting brackets, hardwares etc. as 137 20550
required for fixing. Each 150.00

8 NS All type of Post Top luminiare complete with controlgear on upto 4 Meter high poles
194 29100
etc. as required for fixing. Each 150.00

9 NS All type of Street Light luminiare complete with controlgear on upto 7 Meter high
139 27800
poles etc. as required for fixing. Each 200.00

10 NS All type of Bollard light complete with all fixing hardwares etc. as required for fixing.
26 3120
Each 120.00
Sub-Head-I : Preamble to BOQ for MV Panels
Item Quantity Amount
S.N. Description Unit Rate Remarks
code DSR NON DSR DSR NON DSR
11 NS All type of Under water light complete with cutting of brick-work, grouting of box,
24 3600
and making good of the same with cement mortar plaster. Each 150.00

12 NS Bracket Fan upto 600mm sweep with 3 core flexible wire as required upto socket/
ceiling boxes as required, complete with cutting of wall, grouting of mounting 6 900
braqcket and making good of the wall. Each 150.00

Total of Sub-Head - V carried to summary sheet 1585916 1377895

Sub-Head - VI: Supply of Light Fixtures


Supply of following fans & Light fittings with Electronic Ballast (THD<10%, HF-P),
starter, control gears, lamps holder, transformer etc. as called for and flexible wires 0 0
as required for fixing including providing of Lamps as required. 0.00

1 1 x 36 W Box type Fluorescent luminiare wall/surface mounted including providing


of 36W fluorescent tube rod complete (Philips Cat. No. TMC 55/136 HF or
equivalent) Each
0
2 1 x 36 W Fluorescent Industrial luminiare wall/surface mounted including providing
of 36W fluorescent tube rod complete (Philips Cat. No. TKC 203/136 HF or 305 475800
equivalent) Each 1560.00
0
2.a 0
0
3 1 x 36 W Decorative Surface mounted Fluorescent luminiare including providing of
36W fluorescent tube rod complete (Philips Cat. No. TMS 2001/136 HF or 252 163800
equivalent). Each 650.00
0
4 1 x 36 W Fluorescent Industrial luminiare wall/surface mounted including providing
of 36W fluorescent tube rod complete (Philips Cat. No. TCW 097/136 HF or 0 0
equivalent) Each 2950.00
0
5 2 x 36 W Fluorescent Industrial luminiare wall/surface mounted including providing
of 2 Nos of 36W fluorescent tube rod complete (Philips Cat. No. TCS 605/236 HF 0 0
or equivalent) Each 2950.00
0
6 2 x 36 W Box type Fluorescent luminiare wall/surface mounted including providing
of 2Nos.36W fluorescent tube rod complete (Philips Cat. No. TCS 306/236 HF or 0 0
equivalent) Each 0.00
0
7 1 x 36 W Box type Fluorescent luminiare wall/surface mounted including providing
of 1Nos.36W fluorescent tube rod complete (Philips Cat. No. TCS 19/136 HF or 48 51072
equivalent) Each 1064.00
0
8 Recessed mounted 1 x 36 Watt Fl. luminiare including providing of 1 nos. 36W
12 22800
tube complete.(Philips Cat. No. TBS 50/136 M2 HF or equivalent) . Each 1900.00
0
9 Recessed mounted 2 x 36 Watt Fl. luminiare including providing of 2 nos. 36W
5 13250
tube complete.(Philips Cat. No. TBS 50/236 M2, HF or equivalent) . Each 2650.00
0
Sub-Head-I : Preamble to BOQ for MV Panels
Item Quantity Amount
S.N. Description Unit Rate Remarks
code DSR NON DSR DSR NON DSR
10 Recessed mounted 2 x 36 Watt Fl. luminiare including providing of 2 nos. 36W
86 354750
tube complete.(Philips Cat. No. TBS 369/236 D6 HF or equivalent) . Each 4125.00
0
11 Recessed mounted 2 X 40 Watt fluoresent clean Room luminiare and suitable for
access for lamps from bottom, as approved. (Philips Cat. No. TBS 670/236 TLD-EB 0 0
BO GT or equivalent) . Each
0
12 Recessed type 2 x 36 Watt CFL luminiare including providing of 2 nos. 36W CFL
0 0
complete.(Philips Cat. No. FBS 450/236 HF or equivalent) Each
0
12a Recessed type 2 x 36 Watt CFL luminiare including providing of 2 nos. 36W CFL
162 669060
complete.(Philips Cat. No. FBS 450/236 M2 or equivalent) Each 4130.00
0
13 Recessed type 2 x 18 Watt CFL luminiare including providing of 2 nos. 18W CFL
334 484300
complete.( Philips Cat. No. FBS 285/218 HF or equivalent) Each 1450.00
0
14 Recessed type 2 x 18 Watt CFL luminiare including providing of 2 nos. 18W CFL
6 15000
complete.(Philips Cat. No. FBH 145/218 HF or equivalent) Each 2500.00
0
15 Recessed type 2 x 13 Watt CFL luminiare including providing of 2 nos. 13W CFL
2692 6595400
complete.(Philips Cat. No. FBH 145/213 HF or equivalent) Each 2450.00
0
16 Recessed type 1 x 13 Watt CFL luminiare including providing of 1 nos. 13W CFL
0 0
complete.(Philips Cat. No. FBH 145/113 HF or equivalent) Each 1450.00
0
17 Recessed type 1 x 11 Watt CFL luminiare including providing of 1 nos. 11W CFL
0 0
complete.( Philips Cat. No. FBH 145/111 HF or equivalent) Each 1425.00
0
18 Surface mounted 2 x 9 Watt CFL luminiare including providing of 2 nos. 9W CFL
310 302250
complete.(Philips Cat. No. FCS 518/209 or equivalent) Each 975.00
0
19 Surface mounted 2 x 18 Watt CFL luminiare including providing of 2 nos. 18W CFL
3 3750
complete.( Philips Cat. No. FCS 518/218 or equivalent) Each 1250.00
0
20 Surface mounted 1 x 9 Watt Fl. luminiare including providing of 1 nos. 9W CFL
686 329280
complete.(Philips Cat. No. FMS 200/109 or equivalent) for Mirror Light Each 480.00
0
21 Wall mounted Bedhead 18W FTL light fitting including providing of 1 no.18W
0 0
Fl.tube lamp complete. (Wipro Cat. No. WVF 90118 or equivalent) Each 0.00
0
22 Decorative Bracket/ Picture Light with 13W CFL including providing of lamp
0 0
complete, Bajaj Cat. No.-BJC111 or equiv.) Each 0.00
0
22.a Decorative Bracket/ Picture Light with 13W CFL including providing of lamp
69 37674
complete, Bajaj Cat. No.-BJC111 or equiv.) Each 546.00
0
23 Decorative Chandaliare fitting with CFL as approved by Arch. (optional Item) Each 1500.00 40 60000
0
24 Decorative ceiling mounted 11 Watt Light fixture. (Decon Cat. No.-03TV or equiv.) Each 850.00 4164 3539400
0
25 Bulk head light fitting including providing of 9 W CFL lamp complete (Philips Cat.
0 0
No. FXC 101or equivalent) Each 0.00
0
Sub-Head-I : Preamble to BOQ for MV Panels
Item Quantity Amount
S.N. Description Unit Rate Remarks
code DSR NON DSR DSR NON DSR
25a Bulk head light fitting including providing of 9 W CFL lamp complete (Philips Cat.
5 3925
No. FXC 101or equivalent) Each 785.00
0
26 Decorative Under water Light with 75W Reflector including providing of lamp
0 0
complete.(Philips Cat. No. NHG 10 or equivalent) Each 0.00
0
27 Decorative ceiling mounted 25W Light Fixture (Philips DCOTWIST RIDGE WW
0 0
BCS 1901) or Equivalent. Each 0.00
0
28 Illuminated 2 x 8W CFL exit sign including providing 12 V DC maintenance free
batteries for 60 minutes back-up and battery charger.(Legrand Cat. No. 61736 or 367 6147250
equivalent) Each 16750.00
0
29 Recessed type 2 x 42 Watt CFL luminiare including providing of 2 nos. 42W PL-T
89 442775
Lamp complete.( Philips Cat. No. FBH 225/242 HF-R or equivalent) Each 4975.00
0
30 Decorative integral 70W CDMT Medium bay luminiare with prismatic diffusers,
polycarbonate reflector & bottom cover with fixing ring complete with 1 no. 70W 0 0
CDM-ET lamp (Philips Cat. No. HPK225 1 x CDM-ET 70W PR or equivalent) Each 8100.00
0
31 Flood Light Luminiare with 150W MHN-TD lamp complete with mounting bracket.
99 512325
(Philips Cat. No. MWF 230 AK/150W or equivalent) Each 5175.00
0
32 Decorative integral 150W CDMT Medium bay luminiare with prismatic diffusers,
polycarbonate reflector & bottom cover with fixing ring complete with 1 no. 150W 13 105300
CDM-ET lamp (Philips Cat. No. HPK225 1 x CDM-ET 150W PR or equivalent) Each 8100.00
0
33 1200mm sweep 3 blade Ceiling fan complete with assembling of blades, down rod,
0 0
shackle insulator, canopy etc. (Optional Item) Each 1537.00
0
34 1400mm sweep 3 blade Ceiling fan complete with assembling of blades, down rod,
198 336600
shackle insulator, canopy etc. (Optional Item) Each 1700.00
0
35 Exhaust fan with louver and with 3 core flexible wire of Bajaj/ Newtek/ Crompton
0
make.
a) 300mm 900 RPM Each 2328.00 28 65184
b) 230mm 1400 RPM Each 1306.00 150 195900
c) 600mm dia man cooler bracket fan Each 0.00 0 0
0
36 2 x 11 W Street light luminiare with single piece die cast aluminium housing
including providing of 2 Nos 11W PL-S lamp complete (Philips Cat. No. FRP 51 / 0 0
211 or equivalent) Each 2070.00
0
37 1 x 70 W Street light luminiare with pressure die cast aluminium housing having
POT optics, including providing of 70W SON lamp complete ( Philips Cat. No. 0 0
SGP301 GLA SON 70W(I) or equivalent) Each 3400.00
0
38 1 x 70 W Street light luminiare including providing of 70W SON lamp complete
4 31880
( Bajaj Cat. No. BRSGL 70W SV or equivalent) Each 7970.00
0
39 Bollard Light including providing of 11W CFL as required. (Baja Cat. No. BRBOL
0 0
111 or equivalent) Each. 4530.00
0
Sub-Head-I : Preamble to BOQ for MV Panels
Item Quantity Amount
S.N. Description Unit Rate Remarks
code DSR NON DSR DSR NON DSR
40 Post Top Lantern fitting including providing 18W CFL Lamp as required. (Bajaj Cat.
0 0
No. BRPTCI 118 or equivalent) (Optional) Each. 2375.00
0
41 Post Top Lantern fitting including providing 11W CFL Lamp as required. (Bajaj Cat.
31 69130
No. BRPTCI 111 or equivalent) (Optional) Each. 2230.00
0
42 Extra for Providing Dimmable High frequency Ballast (Electronic- HF-R) for in place
0
of normal Electronic Ballast suitable for following:
18W CFL fitting Each. 750.00 30 22500
36W FL fitting Each. 0
42W CFL fitting Each. 1200.00 80 96000
Total of Sub-Head - VI carried to summary sheet 0 21146355

Sub-Head- VII- Earthing and Lightning Conductor System (DSR Items)


SR-2007
1.1 3.5 Earthing with G.I. earth Plate 600mm x 600mm x 6mm thick including
EARGIP accesssories, and providing masonary enclosure with cover plate having locking
L arrangement and watering pipe etc. (but without charcoal or coke and salt ) as 143 226655
required. Sets 1585.00
1.2 3.8 Extra for using salt and coke for G.I. Or copper plate earth electrocode as required.
EARCO 143 212212
KPL Sets 1484.00

2.1 3.6 Earthing with Cu. earth Plate 600mm x 600mm x 36mm thick including
EARCU accesssories, and providing masonary enclosure with cover plate having locking
PL arrangement and watering pipe etc. (but without charcoal or coke and salt ) as 102 332826
required. Sets 3263.00
2.2 3.8 Extra for using salt and coke for G.I. Or copper plate earth electrocode as required.
EARCO 102 151368
KPL Sets 1484.00

3 3.12
Providing and fixing following sizes of G.I.strip on surface/ existing cable tray /
PVC Pipe complete with all necessary hardwares as required for fixing.
a EARGI25X6
25mm x 6mm RM 60.00 10180 610800

3.18 Providing and fixing 25mm x 5mm GI Strip on surface or in recess for connections
4 EARGIS etc. as required. RM 7650 504900
TSUR 66.00

4.14 Providing and laying 32mm x 6mm G.I. strip


5 LCEAR
GIT Mtrs. 0.00

3.17 Providing and fixing 25mm x 5mm copper Strip on surface or in recess for
6 EARCU connections etc. as required. RM 800 286400
STSUR 358.00

7 3.19 Providing and fixing 6SWG dia GI Wire on surface or in recess for lop earthing as
EARGI required. 14000 336000
WRSUR Mtr 24
Sub-Head-I : Preamble to BOQ for MV Panels
Item Quantity Amount
S.N. Description Unit Rate Remarks
code DSR NON DSR DSR NON DSR
3.23 Providing and fixing of 50mm x 5mm copper strip on surface for connection etc. as
EARBU required. 400 266000
S Mtr 665

8 4.2 LCFGIProviding and fixing of 25mm dia., 300mm long G.I. Rod lightning conductor finial
having single prong at top, with 85mm dia. 6mm thick G.I. base plate including 52 12636
holes etc. complete with all hardwares as required for fixing. Each 243.00

9 4.7 Providing and fixing 20 mm x 3mm GI Strip on parapet or surface of wall for
LCGITS lightning conductor as required. (for horizontal run). 8300 257300
URH Mtrs. 31.00

10 4.8 Providing and fixing G.I. tape 20 x 3mm thick on surface of wall for lightning
LCGITS conductor as required. (For vertical run). 3420 147060
URV Mtrs. 43.00

11 4.12 Providing and fixing of 20mm x 3mm thick G.I. strip, 125mm long test joint with G.I.
104 3848
LCTJGI bolts, nuts, check nuts and spring washers etc. complete as required. Sets 37.00

12 4.14 Providing and laying 32mm x 6mm G.I. strip for earth grid & from test joint to grid.
LCEAR 1410 91650
GIT Mtrs. 65.00

13 3.1 Earthing with G.I. earth pipe 4.5 mtr. long, 40 mm dia including accesssories, and
EARGIP providing masonary enclosure with cover plate having locking arrangement and 112 167552
IP watering pipe etc. (but without charcoal or coke and salt ) as required. Sets 1496.00

14 3.4 Extra for using salt and coke for pipe earth electrocode as required.
EARCO 112 119056
KPIP Sets 1063.00

15 3.1 Earthing with G.I. earth pipe 4.5 mtr long 40 mm dia including accesssories and
EARGIP providing masonary enclosure with cover plate having locking arrangement and
IP + 3.4 watering pipe etc. ( but without charcoal or coke and salt ) as required. Extra for
EARCO using salt and coke for pipe earth electrocode as required. 0 0
KPIP
Sets 0.00

16 4.4 Reverting, sweating & soldering of copper / G.I. tape ( with another copper/ GI
7350 411600
LCRSS tape, base of the finial, or any other metallic object as required. Each 56.00

17 3.14 Providing and fixing 25mm x 5mm GI Strip in 40mm dia GI Pipe earth electroled as
EARGIS required. 2160 470880
TPIP Mtr 218.00

18 3.18 Providing and fixing 25mm x 5mm GI Strip on surface or in recess for connections
EARGIS etc. as required. 1152 76032
TSUR Mtr 66.00

19 3.13 Providing and fixing 25mm x 5mm copper Strip in 40mm dia GI Pipe earth
EARCU electroled as required. 1280 632320
STPIP Mtr 494.00
Sub-Head-I : Preamble to BOQ for MV Panels
Item Quantity Amount
S.N. Description Unit Rate Remarks
code DSR NON DSR DSR NON DSR
20 3.17 Providing and fixing 25mm x 5mm copper Strip on surface or in recess for
EARCU connections etc. as required. 800 286400
STSUR Mtr 358.00

2.71 Providing & fixing of M.V. danger notice plate of 200 mm x 150 mm, made of mild
DANPL steel, at least 2 mm thick, and vitreous enamelled white on both sides, and with 10 680
MV inscription in single red colour on front side as required. Each 68.00

2.71 Providing & fixing of H.V. danger notice plate of 200 mm x 150 mm, made of mild
DANPL steel, at least 2 mm thick, and vitreous enamelled white on both sides, and with 15 1125
HV inscription in single red colour on front side as required. Each 75.00

Total of Sub-Head - VII carried to summary sheet (DSR Items)

Sub-Head- VII- Earthing and Lightning Conductor System (NDSR Items)


Non-Schedule Items
21 NS Providing and fixing following sizes of G.I.strip on surface/ existing cable tray /
PVC Pipe complete with all necessary hardwares as required for fixing.
a 32mm x 6mm RM 120.00 1420 170400
b 40mm x 6mm RM 0.00 0 0

22 NS Providing and Fixing of 8 SWG GI wire. Mtrs. 8.00 17000 136000

23 NS Providing & Laying of following PVC insulated Cu. Conductor unarmoured cable.
a 1C x 120 sq.mm. (MDB-UPS) RM 975.00 200 195000
b 1C x 70 sq.mm.( MRI. CT-Scan & Floor UPS panel) RM 570.00 1000 570000
c 1C x 35 sq.mm. (for Isolation panel, X-ray M/c,Server room & EPABX) RM 240.00 2360 566400
d 1C x 10 sq.mm. (for UPS DBs) RM 103.00 3500 360500
e 1C x 300 sq.mm. (for Chillers and Hot water Generator) RM 5105.00 730 3726650

24 NS Supply, fabrication, erection, testing & commissioning of 2 nos. 300mm long, 25mm
x 6mm thick Copper Bus-bar on insulated PVC stud/ support in 500mm(L) x
400mm(W) x 150mm(D) size of 16SWG, powder coated MS box for dedicated 32 56000
earthing, complete with effecting proper connection of exisiting wires/cables with
copper thimbles. Sets 1750.00

25 NS Providing and laying of following PVC Pipe (6Kg. Pr. Class) in ground
a 65 mm dia pipe RM 135.00 280 37800
b 50 mm dia pipe RM 80.00 300 24000
Total of Sub-Head - VII carried to summary sheet 5605300 5842750

SR-2007 Distribution Boards


1 2.35 Supplying, installtion, testing & comissioning of surface/ recessed mounting
VTTPM Vertical type 415V TPN MCB distribution board of sheet steel, dust protected duly
CBDB Phosphatized and powder painted inclusive of 200 amps tinned Cu. Bas bar,
neutral link, earth bar DIN bar for mounting MCBs, detachable gland/ knockout
plate, and with 100 amps 10KA MCCB as incomer, interconnection between
incomer MCCB 7 bus bar of following ways( but without MCBs) as reqd.
a) 2.35.1 4 ways with 100amps MCCB as incomer Each 2,992.00 7 20,944.00
b) 2.35.2 8 ways with 100amps MCCB as incomer Each 3,553.00 19 67,507.00
c) 2.35.3 12 ways with 100amps MCCB as incomer Each 4,070.00 2 8,140.00
Sub-Head-I : Preamble to BOQ for MV Panels
Item Quantity Amount
S.N. Description Unit Rate Remarks
code DSR NON DSR DSR NON DSR
2 2.42 Supplying and fixing following way, three Pole and neutral, prewired.sheet steel
PWTPM MCB distribution board, 415 volts, on surface/ recess, complete with loose wire box
CBDB terminal blocks duly prewired with suitable size FR PVC insulated copper conductor
up to terminal block,tinned copper busbars, nrutral link, earth bar, dinbar,
detachable gland plate , interconnections including phosphatized and powder
painted including earthing etc. as required.(But without MCB/RCCB/Isolator)

a) 2.42.5 4 Way(4+12), Double door Each 5,395.00 4 21,580.00


b) 2.42.6 6 Way(4+18), Double door Each 6,941.00 50 347,050.00
c) 2.42.7 8 Way(4+24), Double door Each 8,337.00 331 2,759,547.00
d) 2.42.8 12 Way(4+36), Double door Each 9,833.00 184 1,809,272.00

3 2.41 Supplying and fixing following way, single pole and neutral, prewired.sheet steel
PWSPM MCB distribution board, 240 volts, on surface/ recess, complete with loose wire box
CBDB terminal blocks duly prewired with suitable size FR PVC insulated copper conductor
up to terminal block,tinned copper busbars, nrutral link, earth bar, dinbar,
detachable gland plate , interconnections including phosphatized and powder
painted including earthing etc. as required.(But without MCB/RCCB/Isolator)

a) 2.41.5 2+8 WAY Double door Each 3,024.00 47 142,128.00


b) 2.41.6 2+12 WAY Double door Each 3,959.00 268 1,061,012.00
C) 2.41.4 2+4 WAY Double door Each 2,139.00 472 1,009,608.00

4 2.31 Supplying and fixing following way, single pole and neutral, prewired.sheet steel
SPMCB MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper
DB busbars, nrutral bus bar, earth bar, dinbar, detachable gland plate ,
interconnections including phosphatized and powder painted including earthing etc.
as required.(But without MCB/RCCB/Isolator)
a) 2.31.5 4 way, double door Each 450.00 21 9,450.00

5 2.43 Supplying, installation, testing & commissioning of Surface / recessed mounting,


PWTPM Vertical type 415V, prewired.TPN MCB distribution board of shhet steel, dust
CBDB protected, duly phosphatised & powder painted, inclusive of 200 amps tinned
copper bus bar, common neutral link, earth bar, din bar for mounting MCBs,
detachable gland / knockout plate, & with built-in loose wire box and superior make
terminal connectors for all incomer & outgoing circuits, duly prewired with adequate
size of FR PVC insulated Cu. conductor upto terminal connector / neutral link for
installtion of the following ways (but without MCBs & incomer) as required.

a) 2.43.5 4 way, double door Each 6,717.00 6 40,302.00


b) 2.43.6 6 way, double door Each 8,649.00 4 34,596.00
c) 2.43.7 8 way, double door Each 10,394.00 7 72,758.00
d) 2.43.8 12 way, double door Each 12,451.00 4 49,804.00

6 2.56 Supplying & Fixing of following rating double pole (single phase and neutral) 240
RCCBS volts, Residual Current Circuit Breaker (RCCB), having a sensitivity current upto
PN 300 milli-amperes in the existing MCB DB complete with connections, testing and
commissioning etc. as required.
a) 2.56.1 25 Amps Each 949.00 460 436,540.00
b) 2.56.2 40 Amps Each
b.1) 2.56.3 40 Amps Each 1,007.00 1293 1,302,051.00
c) 2.56.3 63 Amps Each 1,343.00 510 684,930.00
Sub-Head-I : Preamble to BOQ for MV Panels
Item Quantity Amount
S.N. Description Unit Rate Remarks
code DSR NON DSR DSR NON DSR
7 2.57 Supplying & Fixing of following rating four pole (three phase and neutral) 240 volts,
RCCBT Residual Current Circuit Breaker (RCCB), having a sensitivity current upto 300 milli-
PN amperes in the existing MCB DB complete with connections, testing and
commissioning etc. as required.
a) 2.57.1 25 Amps Each 0 -
b) 2.57.2 40 Amps Each 1,208.00 44 53,152.00
c) 2.57.3 63 Amps Each 0 -
d) 2.57.3 63 Amps Each 1,426.00 36 51,336.00

8 2.51 Supplying & fixing 5 amps to 32 amps rating 240 volts `B' series, Miniature Circuit
MCBB Breaker osuitable for Power loads of following poles in the existing MCB DB
complete with connections, testing and commissioning etc. as required.
a) 2.51.1 Single Pole Each 86.00 7336 630,896.00

9 2.52 Supplying & fixing 5 amps to 32 amps rating 240 volts `C' series, Miniature Circuit
MCBC Breaker osuitable for lighting loads of following poles in the existing MCB DB
complete with connections, testing and commissioning etc. as required.
a) 2.52.1 Single Pole Each 94.00 9715 913,210.00
b) 2.52.3 Triple Pole Each 386.00 233 89,938.00

10 2.53 Supply & fixing of single pole blanking plate in the existing MCB DB complete etc.
1618 3,236.00
MCBBP as required Each 2.00

11 2.71 Providing & fixing of M.V. danger notice plate of 200 mm x 150 mm, made of mild
DANPL steel, at least 2 mm thick, and vitreous enamelled white on both sides, and with 31 2,108.00
MV inscription in single red colour on front side as required. Each 68.00
Total of Sub-Head - I carried to summary sheet ( DSR Item)

Distribution Boards (Non- DSR Items)


1 NS Supplying & fixing following rating 415 volts `C' series, Four Pole Miniature Circuit
Breaker in the existing MCB DB complete with connections, testing and
commissioning etc. as required.
a) 32A DP MCB 550.00 517 284,350.00
b) 32A FP MCB 1,168.00 48 56,064.00
c) 40A FP MCB 1,725.00 340 586,500.00
d) 63A FP MCB 1,765.00 0 -
d.1) 63A FP MCB 1,725.00 186 320,850.00
e) 63A TP MCB 1,725.00 4 6,900.00
f) 40A DP MCB 880.00 236 207,680.00
g) 63A DP MCB 880.00 8 7,040.00

2 NS Supplying & fixing following rating of Double/ Four Pole Contactor with 24 Hrs
setting Timer in the existing MCB DB complete with connections, testing and
commissioning etc. as required.
a) 40A TP Contactor, AOM with Timer ( 24 Hrs.) 9,075.00 13 117,975.00
b) 40A DP Contactor, AOM with Timer ( 24 Hrs.) - 0 -

3 NS Supplying & fixing3phase Dual type Energy Meter 415 volts including Sheet Steel
0 -
MS box complete with connections, testing and commissioning etc. as required. -
Total Distribution Boards 11621095 1587359

Sub-Head-IX : Optional Capital Items ( NS Items)


Sub-Head-I : Preamble to BOQ for MV Panels
Item Quantity Amount
S.N. Description Unit Rate Remarks
code DSR NON DSR DSR NON DSR
1 Supply of 230V, 2.5 KVA Inverter complete with Over-load protection relay, battery
charger, 12V, 180 AH Lead Acid battery, Moulded Plastic Cabinet/rack for Battery
& Inverter including interconnection wiring with suitable size of PVC insulated Sets 48000.00 13 624,000.00
Copper wire from battery to Inverter.

2 Supply, Installation, testing & Commissioning of high performance IGBT/PWM base


true on line double conversion fully microprocessor controlled UPS System of
following ratings complete with in-built solid state By-pass switch, complete
including Sealed maintenance free Batteries for 30 minutes back up, complete
with battery racks, inter connection links, DC cable, inbuilt DC isolator with fuse
protection.
2.1 80 KVA Sets 1053000.00 2 2,106,000.00
2.2 60 KVA Sets 911000.00 6 5,466,000.00
2.3 50 KVA Sets 882000.00 2 1,764,000.00
2.4 40 KVA Sets 683000.00 4 2,732,000.00
2.5 30 KVA Sets 598000.00 6 3,588,000.00
2.6 20 KVA Set 501000.00 7 3,507,000.00
2.7 15 KVA Sets 456000.00 1 456,000.00

3 Supply, Installation, testing & Commissioning of following Sensors including


interconnections with suitable size of PVC insulated Cu. Wire from existing junction
box, complete with housing and mounting bracket/ supports for the sensors, as
required.
i) Infrared Occupancy Sensor. Sets 0.00 0 -
ii) Photo Lux Sensor. Sets 0.00 0 -

Total of Sub-Head - IX carried to summary sheet 20,243,000.00

Sub-Head-X: Miscellaneous Items (Non DSR Items)


1 NSI Supplying and fixing of non-skid rubber mat 20mm thick and 900mm width as
required including cutting to required lengths of approved make with Test Mtrs. 2400.00 60 144,000.00
Certificates suitable for 11 KV grade

2 NSI Supplying and fixing of non-skid rubber mat 12mm thick and 900mm width as
required including cutting to required lengths of approved make with Test Mtrs. 1800.00 260 468,000.00
Certificates suitable for 1100 Volt.

3 NSI Supplying and fixing of shock treatment chart written in English and Hindi duly
Each 750.00 6 4,500.00
framed in as required.

4 NSI Supplying and fixing of first aid box as approved complete with standard kit as
Each 1000.00 6 6,000.00
prescribed by Indian Red Cross.

5 NSI Supply of Hand gloves made out of rubber suitable for 1100 volt grade Pairs 800.00 12 9,600.00

6 NSI Supply of Hand gloves made out of rubber suitable for 11000 volt grade Pairs 1500.00 3 4,500.00

Total of Sub-Head - X carried to summary sheet 636,600.00


Sub-Head-I : Preamble to BOQ for MV Panels
Item Quantity Amount
S.N. Description Unit Rate Remarks
code DSR NON DSR DSR NON DSR
Non
DSR Sub-Head-12 : 11 KV HT Equipment & Transformer
Items
1 PACKAGE SUB-STATION
Supply, unloading, shifting, erection, testing & commissioning of Package type sub-
stations (PSS) as per Specifications, complete with 11 KV Switchgears,
Transformers and 1100V switchgear as per specification & as described below:
(Note:-The civil RCC foundation for PSS shall be in the scope of Civil contractor but
approval of related drawings & co-ordination is part of the electrical works/item).

1.1 ESS-1 (Typical for ESS-2)


PSS (Package Sub-Station )-1
A Transformer :-11KV / 433V, 1600 KVA, copper wound, ONAN, delta-star
connected, Dyn11 vector group Transformer with Off circuit tap -link for voltage
regulation from -10% to +5% in steps of 2.5%, complete with OTI, WTI alarm and
Trip contact in Marshalling Box, bidirectional roller and all standard accessories
including providing of inter-connection cable between Trafo. & HT Panel with
3CX120sqmm, 11KV (E)XLPE insulation Al. Ar. cable and 2500A TPN Al. Bus
Duct between LT side of Trafo. & LT Switch.

B HT Panel (Ring Main Unit) :- 1 no. 11KV, 50Hz, 630A, 21KA/ 3sec., Ring Main
Unit consisting of 2 nos.Earthed Isolator & 1 no.VCB / SF6 Motorised Circuit
Breaker for transformer protection & complete with all interconnection with suitable
sizes of Power & Cu. control cables as required, including following Protection &
Metering:
i) Ring core type CT's as follows:
ii) Set I - 90/5A class 5P10 (15VA) for Protection
iii) Set II - 90/5A class 1 (15VA) for Metering
iv) 1 - No. Ammeter(0-60A) with selector switch (Built-in)
v) 1 - KW, KVA, KWH & KVAH Meter
vi) 1 - Set of ON/OFF/Trip/ Spring Charged and phase indicating lamps.
vii) 1 - No.extra Push Button for Emergency Trip outside of the PSS Enclosure, in a
lockable transparent Box.
viii) Cable Termination box suitable for 3C x 240 sq.mm.11 KV(E), aluminium conductor
XLPE Ar. cable .
ix) 1- set of self powered Microprcessored based relay for IDMTL protection for 3-O/C
protection (50%-200%) & 1-E/F protection (10%-40%)
x) Auxiliary/ Shunt relay for OTI, WTI & Bucholtz Tripping
xi) 1 no. 8 window Annunciation system for alarm & Trip condition for Transformer &
Breakers complete with acknowledgement & Reset Button.
Interconnection - 3x1Cx95 sq.mm. xlpe Al. ar. Cable, 11KV grade between HT
switchgear & Transformer and 1600A TPN Al. Bus-bar between Transformer & LT
panel
C LT Switch - 1 nos. 1600 A FP MDO ACB having microprocessor based
programmable trip setting for S/C, O/C & E/F protection complete with Phase
indicating, Spring Charged & Trip indication Lamps, Multifunction Meter for Volt.,
Current, KW, KVA & P.F.
Supply Rate for Package Substation-1 as described above Sets 3,676,000.00 2 7,352,000.00
Installation & Commissioning Rate for Pakage Substation-1 as described
Sets 53,000.00 2 106,000.00
above
Sub-Head-I : Preamble to BOQ for MV Panels
Item Quantity Amount
S.N. Description Unit Rate Remarks
code DSR NON DSR DSR NON DSR
2 11 KV HT ESS Panel (13-switch HT Panel)
Supplying/Receiving, Installation, testing and commissioning of HT three panel
board suitable for indoor installation for use on 11 KV, 50 C/S earthed system
having a symmertrical breaking capacity of 350 MVA for 1 Sec. at 11 KV
comprising VCB/SF6 circuit breaker Panel shall be equipped with following
accessories and as per specifications and schematic drawing. ( Note; In case of
SF6 breaker Power pack of 200% of peak Trip current requirement shall be
provided with each breaker)

A INCOMINGING PANELS - 2 Nos. & EACH SHALL COMPRISING OF:


i) 1No. - Metal Clad housing with having 1250A Vacumm circuit/ SF6 breaker with
Manual & Electric operated mechanism (spring charged motor - 230V AC)
ii) 1Set- Tripping coil & closing Coil 24V DC
iii) 1 - Set of isolating plug and receptacle
iv) 1 - Set of Automatic safety shutter
v) 1- Set of breaker control switch (TNC)
vi) 1 -Set of dual core CT's as follows:
vii) Core I -200-400-600/5-5A class 5P-10 (15 VA)
viii) Core II - 200-400-600/5-5A class -1 (15 VA)
ix) 1set of 11/ 3KV / 110/ 3 Volt, 100 VA burden & accuracy class 1, 3 nos. single
phase construction, dry type cast resin PT
x) 1 - Multifunction Meter with selector switch for per phase Current, Voltmeter, KW,
KWH, Reactive & Active power & frequency.
xi) 1 - Set of ON/OFF/Trip/ Spring Charged & Trip circuit healthy and phase indicating
lamps.
xii) 1 No.- H.T. Cable joint box suitable for 2R - 3C x 400 sq.mm aluminium conductor
XLPE cable, 11 KV (E)
xiii) 1- set of IDMTL relay with 3 elements of O/C protection(50%-200%), instantaneous
O/C protection (200%-800%) & 1 element of E/F protection (10%-40%).

xiv) 1 no. U/V & O/V relay


xv) 1 no. Anti Pumping Relay
xvi) 1 no. Trip Circuit supervision relay.
xvii) 1 no. Negative phase sequence protection relay.
xviii) 1 no. Master Trip relay.
xix) 1 no. 8 window Annunciation system for alarm & Trip status of relays, HT Breakers
complete with acknowledgement & Reset Button.
B. BUS COUPLER:-
i) 1 nos. 1250 Amp TP Vacuum/ SF6 circuit breaker.
ii) 1 Set of Breaker ON-OFF-TRIP indication Lamps with each Bus Coupler

C INTERLOCKING.
i) Both Incomers from grid Transformer & Bus couplers shall be electrically &
mechanically interlocked.

D Bus Bar : - 2 Set of 1200 amps TP air insulated Cu. bus bar & chamber.
E OUTGOING PANELS:
E.1 2 Nos. & EACH SHALL COMPRISING OF:
i) 1 - Metal clad housing with having 800A Vacuum/ SF6 circuit breaker Manual &
Electric operated mechanism (spring charged motor 230VAC)
ii) 1 - Tripping coil & closing Coil 24V DC
iii) 1 - Set of isolating plug and receptacle
iv) 1 - Set of Automatic safety shutter
Sub-Head-I : Preamble to BOQ for MV Panels
Item Quantity Amount
S.N. Description Unit Rate Remarks
code DSR NON DSR DSR NON DSR
v) 1- Set of breaker control switch (TNC)
vi) 1 -Set of dual core CT's with Ammeter as given below for outgoing feeders
respectively:
a. Core I - 180-360/5-5A class 5P-10 (15VA)
b. Core II - 180-360/5-5A class I (15VA)
vii) 1 - Multifunction Meter with selector switch for per phase Current, Voltmeter, KW,
KWH, Reactive & Active power & Power factor.
viii) 1- Set ON/OFF, Trip & Trip ckt healthy indication lamp
ix) 1 No.- H.T. Cable joint box suitable for 2R - 3C x 300 sq.mm aluminium conductor
XLPE cable, 11 KV (E)
x) 1- set of IDMTL relay with 3 element of O/C protection(50%-200%), Instantanous
Over Current protection(200%-800% and 1 element of E/F protection (10%-40%)
xi) 1 - Aux. relay
xii) 1 - Trip circuit supervision relay
xiii) 1 - no. Anti Pumping Relay
xiv) 1 - Master Trip relay
xv) 1 No.- 8 window Annunciation system for alarm & Trip status of relays, HT Breakers
complete with acknowledgement & Reset Button.
E.2 8 Nos. & EACH SHALL COMPRISING OF:
i) 1 - Metal clad housing with having 630A Vacuum/ SF6 circuit breaker Manual &
Electric operated mechanism (spring charged motor 230VAC)
ii) 1 - Tripping coil & closing Coil 24V DC
iii) 1 - Set of isolating plug and receptacle
iv) 1 - Set of Automatic safety shutter
v) 1 - Set of breaker control switch (TNC)
vi) 1- Set of dual core CT's with Ammeter as given below for outgoing feeders
respectively:
a. Core I - 90/5A class 5P-10 (15VA)
b. Core II - 90/5A class I (15VA)
vii) 1- Multifunction Meter with selector switch for per phase Current, Voltmeter, KW,
KWH, Reactive & Active power & Power factor.
viii) 1- Set ON/OFF, Trip & Trip ckt healthy indication lamp
ix) 1 No.- H.T. Cable joint box suitable for 3C x 300 sq.mm aluminium conductor
XLPE cable, 11 KV (E)
x) 1- set of IDMTL relay with 3 element of O/C protection(50%-200%), Instantanous
Over Current protection(200%-800% and 1 element of E/F protection (10%-40%)
xi) 1 - Aux. relay
xii) 1 - Trip circuit supervision relay
xiii) 1 - no. Anti Pumping Relay
xiv) 1 - Master Trip relay
xv) 1 no. 8 window Annunciation system for alarm & Trip status of relays, HT Breakers
complete with acknowledgement & Reset Button.
Supply Rate for HT Panel as per specification & as described above Set 6,584,000.00 1 6,584,000.00
Installation & Commissioning Rate for HT Panel as per specification & as
Set 65,000.00 1 65,000.00
described above

3 Main 11 KV HT Panel (1-switch HT Panel)


i) Supplying/Receiving, Installation, Testing and Commissioning of 11 KV H.T. Panel
complete with 1250 amps TP VCB having a symmetrical fault of 350 MVA for 1 sec.
including CT's and PT's with the following:
ii) 1 - Metal Clad housing with truck having 1250A TP integral VCB with Electric
operated mechanism (spring charged motor - 230V AC), Tripping coil & closing Coil
24V DC
Sub-Head-I : Preamble to BOQ for MV Panels
Item Quantity Amount
S.N. Description Unit Rate Remarks
code DSR NON DSR DSR NON DSR
iii) 1 - Set of 1200A TP air insulated Cu bus bar & chamber.
iv) 1 - Set of isolating plug and receptacle.
v) 1 - Set of Automatic safety shutter.
vi) 1 - Set of breaker control switch (TNC)
vii) 1 - Set of ON/OFF/Trip & Trip circuit healthy and phase indicating lights.
viii) 1set of 11/ 3KV / 110/ 3 Volt, 100 VA burden & accuracy class 0.5, 3 nos. single
phase construction, dry type cast resin PT.
ix) 1 -Set of dual core CT's with Ammeter as given below for outgoing feeders
respectively:
x) Core I - 600-400/5-5A class 5P-10 (15VA)
xi) Core II - 600-400/5-5A class I (15VA)
xii) 2 Sets of HRC fuses with fuse base (H.T. Fuse - 1A & LT fuse 2-6A).
xiii) 1 No. digital multifunction meter having voltage, current, frequency, Power factor &
KW reading parameters with selector switch.
xiv) 1- set of IDMTL relay with 3 element of O/C protection(50%-200%), Instantanous
Over Current protection(200%-800% and 1 element of E/F protection (10%-40%)
xv) 1 - Trip circuit supervision relay
xvi) 1 - no. Anti Pumping Relay
xvii) 1 - Master Trip relay
1 no. 4 window Annunciation system for alarm & Trip status of relays, HT Breakers
xviii) complete with acknowledgement & Reset Button.
2 Nos. cable end box for suitable for 3C x 300 sq.mm.11 KV(E), aluminium
xix) conductor XLPE Ar. cable (Incoming & Outgoing cable).
Supply Rate for HT Panel as described above Sets - 0 -
Installation & Commissioning Rate for HT Panel as described above Sets - 0 -

4 Supply, erection, testing and commissioning of 230V, single phase 2 wire AC to


24V DC Batteries charger with semiconductor/IGBT fullwave rectifier with auto
/manual float cum boost facility complete with 24V DC, 200 AH sealed maintenance
free batteries including one no. distribution board having 63 Amps DP MCCB as
Sets 90,000.00 2 180,000.00
incomer and 16 Nos. 20/16A DP MCB's (D.C. duty) as outgoing complete as
required and as per technical specifications

-
5 Transformer
Supplying/Receiving, Installation/Erection, Testing and Commissioning of 1600
KVA ONAN, Copper wound 11/0.433 KV, 50 C/S, Delta star connected, Dyn11
vector group, Oil immersed Outdoor transformer with On Load Circuit Tap changer
for Voltage regulation from -10% to +5% in steps of 1.25% on HV side complete
with AVR and RTCC panel, including Bucholtz relay, MOG, Oil & Winding
temperature alarm and trip contacts with wiring upto marshalling box,and all
standard accessories as required, complete with Cable End box suitable for 3C x
300 sq.mm. 11 KV(E) XLPE insulated Al. Ar. Cable at HT side and 3200 amps TPN
Al. Bus duct for LT side, including S/F of M.S. channel of size 100 x 50 x 6mm for
foundation support for transformer,including Drying/filteration of oil of transformer
and OLTC Enclousere.Connection with Tap Changing Mechanisem and RTCC
Panel etc. as per specification and drawing.

Supply Rate for Transformer as described above Sets 2,057,000.00 8 16,456,000.00


Installation & Commissioning Rate for Transformer as described above Sets 34,000.00 8 272,000.00

6 Supplying of following Aluminum conductor, XLPE insulated & armoured and over
all PVC sheathed, 11 KV (E) grade earthed cable as per technical specifications
Sub-Head-I : Preamble to BOQ for MV Panels
Item Quantity Amount
S.N. Description Unit Rate Remarks
code DSR NON DSR DSR NON DSR
3C x 400 sq.mm. XLPE insulated Al. Ar. Cable RM - 0 -
3C x 300 sq.mm. XLPE insulated Al. Ar. Cable RM 2,594.00 150 389,100.00
3C x 240 sq.mm. XLPE insulated Al. Ar. Cable RM 2,251.00 800 1,800,800.00

7 Supplying, and making Indoor/ Outdoor cable end termination with Heat shrinkable
jointing kit complete with all accessories, including lugs suitable for following sizes
of 3 core XLPE aluminum conductor cable of 11 KV grade as required.

i) Indoor Type
3C x 400 sq.mm. XLPE insulated Al. Ar. Cable Each -
ii) Outdoor Type
3C x 400 sq.mm. XLPE insulated Al. Ar. Cable Each -
Total of Sub-Head - I Non DSR Total
DSR
Item
Code
8 5.4 Supplying, and making Indoor cable end termination with Heat shrinkable jointing
11HXLIJ kit complete with all accessories, including lugs suitable for following sizes of 3 core
XLPE aluminum conductor cable of 11 KV grade as required.

8.1 Indoor Type


i) 5.4.4 3C x 300 sq.mm. XLPE insulated Al. Ar. Cable Sets 3,390.00 8 27,120.00 -
ii) 5.4.3 3C x 240 sq.mm. XLPE insulated Al. Ar. Cable Sets 3,390.00 22 74,580.00 -

9 2.2 Laying of one no.PVC insulated & PVC sheathed/ XLPE power cable of grade
11CBG exceeding 1.1.KV but not exceeding 11KV of size exceeding 120 sq.mm. but not
R400 exceeding 400 sq.mm. direct in ground including excavation, sand cushioning, Metre 121.00 280 33,880.00 -
protective covering andd refilling the trench etc. as required.

10 2.4 Laying of one no. additional PVC insulated & PVC sheathed/ XLPE power cable of
11CBG grade exceeding 1.1.KV but not exceeding 11KV of size exceeding 120 sq.mm. but
RT400 not exceeding 400 sq.mm. direct in ground in the same trench in one tier horizontal Metre 78.00 220 17,160.00 -
formation including excavation, sand cushioning, protective covering andd refilling
the trench etc. as required.

11 2.6 Laying of one no.PVC insulated & PVC sheathed/ XLPE power cable of grade
11CBO exceeding 1.1.KV but not exceeding 11KV of size not exceeding 400 sq.mm. In Metre 25.00 450 11,250.00 -
D400 the existing masonary open duct as required.

Total HT Cable 163,990.00 33,204,900.00

Sub-Head-XIII : External Lighting


Sub-Head-I : Preamble to BOQ for MV Panels
Item Quantity Amount
S.N. Description Unit Rate Remarks
code DSR NON DSR DSR NON DSR
1 Supply, Assembling and Erection of 76mm dia.(5mm Av.thickness) 4 meter long
GRP Pole (reinforced polymer composite) of pre-pegmented approved colour with
bracket for Post top lantern fitting, burried 750mm deep in prefabricated MS
foundation housing, grouted & embedded in 300mm x 300mm, 1.0 meter deep and
250 mm above ground PCC (1:3:6) foundation complete with excavation and Sets 15000 194 2,910,000.00
removal of surplus soil as required, complete with integral J.box with 10/16A SP
MCB and 3 way connector, fixing of 40 mm dia. `B' class G.I. pipe of suitable length
for cable entry, including providing of 3x1.5 sq.mm. Cu. wire from JB to Light fittings
as required.

2 Supply, Assembling and Erection of 7 meter long Tubular jointless G.I. Pole with
180mm dia. at base & 80mm dia.at top, of suitable thickness to withstand wind
speed of 180 km/hr., complete with 40mm dia., 750mm long single / double arm
G.I. bracket, nipple for street light fitting, grouted & embedded 1000mm deep in
450mm x 450mm, 1.2 meter deep and 400mm above ground PCC (1:3:6)
foundation complete with excavation and removal of surplus soil as required,
complete with integral J.box with 10/16A SP MCB and 3 way connector, fixing of 40
mm dia. `B' class G.I. pipe of suitable length for cable entry, including providing of
3x1.5 sq.mm. Cu. wire from JB to Light fittings as required, including painting with 2
coats of Al.colour paint.

a) Poles with Single bracket Sets 12500 73 912,500.00


b) Poles with Double bracket Sets 15000 66 990,000.00

3 Supply, Assembling and Erection of 30meter High Winch Mast Polygonal Pole with
10 nos. Flood light fixtures & controlgear, fabricated from continuously tapered
folded steel section of suitable size & thickness to withstand wind speed of 180
km/hr., complete with all standard accessories like winches, lantern carriage etc.
including the cost of providing foundation and base pedestal of approved design
incorporating a suitable cable looping box with terminal blocks, MCBs etc. and
including Power tool consisting of 3 phase, 415V, 50Hz, IP-55 and above reversible
motor, suitable Chord connected control module to operate from appx 5meter
distance, protection interlocks and accessories as required, including providng of Sets 600000 3 1,800,000.00
80 mm dia. `B' class G.I. pipe of suitable length for cable entry, 3x10/6 sq.mm. Al.
Unar.cable as required from JB to Light fittings as required, including painting with
2 coats of Al.colour paint, & as per specs. including providing of 400W SON-T
Flood Light Luminiares with lamps complete

4 Supply and erection bracket for Gate light of 750mm long, 40mm dia. MS pipe with
300mm x 300mm x 6 mm thick MS base plate including grouted 300 mm deep with
PCC in column of gate, grouting/fixing of suitable size of J.box with 10/16A SP
MCB and 4way connector, 40 mm dia. `B' class G.I. pipe of suitable length for
cable entry, 3x1.5 sq.mm. Cu. wire from JB to Light fittings as required, complete Sets 1500 31 46,500.00
with painting with 1 coat of primer and 2 coat of white enamel paint or approved
colour complete with recieving, assembling and fixing of light fitting on the pole.

5 Supply and making of 600mm deep PCC (1:3:6) foundation with grouting bolts of
suitable size as reuired for mounting of Bollard Light as per vendor's drawing,
including providing of 40mm dia. G.I. Pipe for cable entry complete with recieving, Sets 900 26 23,400.00
assembling and fixing of Bollard light.
Sub-Head-I : Preamble to BOQ for MV Panels
Item Quantity Amount
S.N. Description Unit Rate Remarks
code DSR NON DSR DSR NON DSR

6 Supply, fixing testing & commissioning of Suitable size of Weather Proof J.box
Nos. 125 31 3,875.00
(Hensel Make) mounted on wall/ MS angle as required.

Total of Sub-Head - XIII External Lighting 6,686,275.00


Balance work for Construction of ESIC Medical College and Hospital at Bihta ,Patna(Bihar)

SUMMARY SHEET

SECTION DESCRIPTION AMOUNT ( In Rs. )

1 SEWAGE TREATMENT PLANT 10,926,280.00

TOTAL 10,926,280.00
Balance work for Construction of ESIC Medical College and Hospital at Bihta ,Patna(Bihar)

S.No. Description of Item Quantity Amount


A) SEWAGE TREATMENT PLANT: Rate Remarks
Unit DSR NON DSR DSR NON DSR

3 4 5 6 7 8 9
1

a) Capacity A/D cum/hr. @ A/D m head-2 Sets.

b) Plant room sump pump A/D cum / hr @ A/D m head- 2 Sets

2 Sewage Treatment Plant Based on Fludised Media Reactor:

Package type Sewage Treatment Plant based on Fludised Media Reactor


below ground for a sewage handling capacity of 900 cum. Per day. The
raw sewage collection sump, bar screen, grit chamber, sludge sump,
chlorine contact tank, treated water collection sump shall be a part of the
STP & shall be designed as water retaining structures in RCC M – 20.>
The Fludised Media Reactor , tube settler shall be M. S. epoxy coated,
non-skid type, including piping, valves, necessary chemical dosing as
required by the manufacturer’s design. All the equipments, piping,
pumps, blowers and electrical are to be housed in a plant-room including
MS puddle flanges, inlet, outlet, overflow vents. The STP shall be
designed based on the following parameters :

pH -- 6.0 – 8.5

BOD5 -- 500 mg/lt

COD -- 1000 mg/lt.

SS -- 400 mg/lt.

Oil & Grease – up to 50 mg/lt.

EColi -- 106 MPN/100 ml


S.No. Description of Item Quantity Amount
A) SEWAGE TREATMENT PLANT: Rate Remarks
Unit DSR NON DSR DSR NON DSR

After the filtration plant :

pH -- 6.0 – 8.5
BOD5 -- 30 mg/lt
COD -- 100 mg/lt.

SS --100 mg/lt.

Oil & Grease --upto 10 mg/lt.

EColi -- 103 MPN/100 m

The STP shall consists of following units:

Bar Screen cum Grit chamber (Gravity type) – for epoxy coated,
manually cleaned, MS bar screen having provision for lifting, etc.

- screen chamber in RCC.-1 No.

– Grit Chamber in RCC.- 1 No.

– Collection / Equalization tank in RCC.-1 No.

Plant room sump 1.5 x 1.5 x 1.5 m swd

Collection cum equalization sump. Provision for aeration of sump may


be kept to avoid any smell problems.

Secondary Clarifier (Tube settler) in MS epoxy construction fitted with


PVC tubular media at 60 deg. Angle of suitable layer height & surface
area with baffle wall and launders at outlet etc. with arrangement of
draining sludge from the bottom.
S.No. Description of Item Quantity Amount
A) SEWAGE TREATMENT PLANT: Rate Remarks
Unit DSR NON DSR DSR NON DSR

– 2 no.

Chlorine contact tank in RCC with baffles for chlorine mixing and desired
minimum vol. As it is also acting as a sump for the filter feed pumps /
back wash sump.

A/D capacity-1 No.

Treated water storage tank in RCC for collection of treated water.

A/D Capacity-1 No.

HDPE hypochlorite solution tank (cap. 200 ltrs.) with constant head
dosing box.

Sludge Storage Sump in RCC with air grid for sludge mixing.

A/D Capacity-1 No.

Foundations for all pumps, blowers & other equipment of suitable size in
RCC.1 No.

Designing, supervising, providing, fixing and installing STP as mentioned


above excluding civil works.-1 No.

Note: All the Civil Works including equipment foundation shall be in the
scope of the Owners. The contractor shall co-ordinate, supervise and get
all the inserts installed. All MS works shall be in the scope of the
contractor.Drawings will be provide by the S.T.P.contractor.- 1 Job

3 Media Feed Pumps:


S.No.
3 Description of Item Quantity Amount
A) SEWAGE TREATMENT PLANT: Rate Remarks
Unit DSR NON DSR DSR NON DSR

Providing and fixing Horizontal centrifugal pumping set for Media feed
sewage. The pumps shall have CI casing & impeller, mono block type &
connected by a flexible tier type coupling to a TEFC induction motor
mounted on a common channel base-plate with coupling guard,. Pressure
gauge, GM isolation cock. Including all necessary piping, valves and
other accessories from STP to filtration units and soft water tanks.
Concrete foundations complete as required.

a) Capacity A/D LPH @ A/D m head- 2 Nos.

4 Filter Feed Pumps :

Providing and fixing Horizontal centrifugal pumping set for filtration and
feed pumps and discharging into the irrigation water tank. The pumps
shall have CI casing & impeller, monoblock type & connected by a
flexible tier type coupling to a TEFC induction motor mounted on a
common channel base-plate with coupling guard,. Pressure gauge, GM
isolation cock. Including all necessary piping, valves and other
accessories from STP to filtration units and soft water tanks. Concrete
foundations complete as required.

a) Capacity A/D LPH @ A/D m head

5 Treated Water Distribution Pumps :

Providing and fixing horizontal, centrifugal Treated water transfer pumps,


mono-bloc-type. The pumps shall have CI casing, CI impeller connected
by the flexible tier type coupling to a TEFC induction motor mounted on
a common channel base-plate with coupling guard, 150 mm dia pressure
gauge, GM isolation cock. Including all necessary piping, valves and
other accessories.

a) Capacity A/D LPH @ A/D m head- 2 Nos.


S.No. Description of Item Quantity Amount
A) SEWAGE TREATMENT PLANT: Rate Remarks
Unit DSR NON DSR DSR NON DSR

6 Sludge Pumps :

Providing and fixing screw type pump to transfer sludge from the
secondary setting tank to sludge sump & disposal. Also sludge pump to
be provided at sludge sump for pumping the collected sludge for disposal.
The pumps shall be in alloy steel construction connected by a flexible tier
type coupling to a TEFC induction motor mounted on a common channel
base-plate with coupling guard, 150 mm dia pressure gauge, GM isolation
cock. Motor to be suitable for 400 / 440 V, 3 Phase, 50 cycles AC power
supply including all necessary piping, valves and other accessories.

a) Capacity A/D LPH @ A/D m head for Sludge Transfer-2 Nos

b) Capacity A/D LPH @ A/D m head for sludge disposal- 2 Nos

7 Dual Media Filter

Providing, fixing, testing & commissioning of vertical pressure filter


fabricated from 5 mm thick. MS sheet as per manufacturer’s
specifications with MS frontal piping and multiport valve to provide
service, backwash and rinsing operations. Complete with initial charge of
filter media. Including painting inside with two coats of non toxic water
paint, one coat of zinc chromate two coats of synthetic enamel paint
outside.

Test pressure – A/D kg/cm2

Capacity A/D Ltr./hr.- 1 Set

8 Activated Carbon Filter


8
S.No. Description of Item Quantity Amount
A) SEWAGE TREATMENT PLANT: Rate Remarks
Unit DSR NON DSR DSR NON DSR

Providing and fixing vertical MS filter using activated carbon as filter


media. The shell shall be fabricated from 5 mm thick MS plate ends
complete with initial charge of filter media. MS frontal piping, with
multiport valve for service, rinse and backwash along with other
accessories. Including painting inside with two coats of non toxic water
paint, one coat of zinc chromate two coats of synthetic enamel paint
outside.

Test pressure - A/D kg/cm2

Capacity - A/D ltrs./hr.-1 Set

9 Softener- optional

Providing and fixing vertical MS filter resin for hardness removal. The
shell shall be fabricated from 5 mm thick MS shell and 5 mm thick MS
plate ends complete with initial charge of resin, PVC/HDPE brine tank of
suitable capacity with ejector & MS frontal piping with multiport valve,
fittings for service, regeneration and rinsing along with other accessories.
Including painting inside with two coats of non toxic water paint, one
coat of zinc chromate two coats of synthetic enamel paint outside.

Test pressure - A/D kg/cm2

Capacity- A/D ltrs / hr.

Regeneration Period – twice a day

Total Inlet Hardness - …. ppm

Outgoing hardness - < 50 ppm

10 Electrical Panel
S.No. Description of Item Quantity Amount
A) SEWAGE TREATMENT PLANT: Rate Remarks
Unit DSR NON DSR DSR NON DSR

10.1 Supply, installation, testing and commissioning of electrical panel,


modular type, front accessible only, free floor standing confirming to
Minimum IP:42 degree of protection as per Manufacturers standard or as
follows. The panel sheet structure shall be powder coated. The sheet steel
shall be all of 2 mm thick CRCA sheet. All the open able compartments
of the panel shall be completely shrouded. All bus bar links in the panel
shall be solid bus bars with coloured PVC shrinkable sleeves, no wires
will be acceptable. Continuous earth bus shall run around the panel with
earthing studs provided at minimum 2 places. The control wiring shall be
carried out with minimum 1.5 sq. mm copper wires and adequate for
remote operation of the starters. Proper sized cable termination gland
plates shall be provided on cable alleys. The panel shall be provided with
a thermostatically controlled heating arrangement (200W) to take care of
high humidity conditions. A 5A socket service outlet (single phase) shall
be provided in one of the compartments as service outlet in the panel.
Panel shall be so designed at to have minimum 10% spare feeders. Panel
shall undergo epoxy powder coated paint, colour as per IS:5
requirements. All cable terminations shall be from top.

All bus bars shall be of aluminium, electrolytic grade only. Maximum


design density shall not exceed 1Amps./Sq. mm.

All bus bars shall be insulated with coloured heat shrinkable PVC
sleeved. All bus bar supports shall be non hygroscopic DMC / SML
supports.

The minimum clearances between bus bars shall be as follows :

a) Phase to phase – minimum 20 mm

b) Phase to neutral – minimum 15 mm

11 Effluent Treatment Plant Panel:


S.No. Description of Item Quantity Amount
A) SEWAGE TREATMENT PLANT: Rate Remarks
Unit DSR NON DSR DSR NON DSR

A. Incomer Section :

One (1) Nos. TPN FSU

One (1) No. ammeter with ammeter selector switch & required CTs.

One (1) No., 0-500 V, voltmeter with voltmeter selector switch

B. Bus Bars :

Set of TPN aluminum bus bars suitable for 415V.

C. Outgoings :

DOL starter …
DOL starter shall consist of following components :

a) TP – FSU – 1 no.
b) Power contactor – 1 no.
c) Overload relay – 1 no.
d) Push button with 1 element – stop.
e) Control fuse – 1 no.
f) Motor On / OFF lamp – 1 no each.

Star Delta starter …..


Star delta starter shall consist of following components :

a) TP – FSU – 1 no.
b) Power contactors – 3 nos.
S.No. Description of Item Quantity Amount
A) SEWAGE TREATMENT PLANT: Rate Remarks
Unit DSR NON DSR DSR NON DSR

c) Over load relay – 1 no.


d) Timer – 1 no.
e) Push button with 1 element – stop.
f) Control fuse – 1 no.
g) Motor ON / OFF lamp – 1 no each.

Note: Switchgear ratings for DOL / SD starters shall be as per


manufacturers standard selection chart. – 1 Set.
Above total job Set 10926280 1 10926280
Balance work for Construction of ESIC Medical College and Hospital at Bihta ,Patna(Bihar)

SUMMARY SHEET OF HVAC

SUBHEAD SECTIONS DSR NON DSR Amount

A HIGH SIDE-A 122,703,658.00 122,703,658.00

B LOW SIDE-(B1 & B2) 336,450,331.00 336,450,331.00

TOTAL ( In Rupees) - 459,153,989.00 459,153,989.00


Balance work for Construction of ESIC Medical College and Hospital at Bihta ,Patna(Bihar)

HVAC

Rate (Rs.) Quantity Amount


S.N. Description Unit Remarks
DSR NON DSR DSR NON DSR
1 2 3 4 5 6 7 8 9

Section-A- High Side

1 WATER CHILLING UNIT


Supply, installation, testing and commissioning of Centrifugal type water
chilling unit with variable speed drive (VSD) of 700 TR actual capacity at the
parameters indicated below. complete with compressors, motor, insulated
chiller, water cooled condenser, vibration isolators, integral refrigerant piping
and wiring, flow switches at chiller and condenser outlets, first charge of
refrigerant and lubricant, microprocessor based control panel, accessories as
required and called for, automatic and safety controls and all mounted on a
steel frame as per specifications. Motor shall be suitable for 415 ± 10% V,
50Hz, 3ph AC supply as per specification. (6 working and 1 Standby)

Chiller
Chilled water in : 54o F
Chilled water out : 44o F
Chilled water flow rate: 1680 USGPM
Fouling Factor : 0.0005 (FPS)

Condenser
Condenser water in : 90o F
Condenser water out : 97.5o F
Condenser water flow rate: 2800 USGPM
Fouling Factor : 0.001 (FPS) Nos. 14690100 7 102830700

2 PUMPS
Rate (Rs.) Quantity Amount
S.N. Description Unit Remarks
DSR NON DSR DSR NON DSR

Supply, installation, testing and commissioning of End Suction Back pull out
centrifugal pumps complete with motor, base frame, vibration isolators, drain
valves and other accessories (except suction and discharge shut off valves,
suction strainer, discharge check valves and drain piping which are covered
under separate item). Pumps shall have mechanical seal and Bronze Impeller.
The pump motor shall be suitable for 415 Volts ± 10%, 50 cycles, 3 phase
power supply. The quoted price shall include cost of thermal insulation and
cladding for chilled water pumps as well as M.S base frame for mounting
both pump and motor along with VI pads. Pumps shall be complete as per
specifications and shall have operating parameters as given below:

2.1 Primary Chilled water pumps


Water flow rate : 1680 USGPM
Head : 12M
Motor HP : 30 HP(suggested) Nos. 264491 7 1851437
(1 No. standby pump included in above quantity)

2.2 Condenser water pumps


Water flow rate : 2800 USGPM
Head : 25M
Motor HP : 80 HP(suggested) Nos. 489521 7 3426647
(1 No. standby pump included in above quantity)

2.3 Secondary chilled water pumps

Water flow rate : 1800 USGPM


Head : 24M
Motor HP : 60 HP(suggested) Nos. 692771 7 4849397
(1 No. standby pump included in above quantity)

Microprocessor based BMS compatible, variable frequency speed controller


2.3.1 7
complete with necessary fittings and wiring Sets Incl in above

2.3.2 Controllers suitable to control 6 nos. pumps separately No. Incl in above 1

2.3.3 Sensor / Transformer Nos. Incl in above 7

2.4 Hot Water Pump for OT


Rate (Rs.) Quantity Amount
S.N. Description Unit Remarks
DSR NON DSR DSR NON DSR
Water flow rate : 20 USGPM
Head : 12M
Motor HP : 1.5 HP(suggested) Nos. 59874 3 179622
(1 No. standby pump included in above quantity)

3 COOLING TOWER

Supply, installation, testing and commissioning of induced draft cooling


towers . Each tower shall be complete with distribution system, fillings,
louvers, Hot dipped galvanised ladder, axial flow fan and motor. Motor
(IP:55) shall be suitable for 415 ± 10% volts, 50 cycles, 3 phase power
supply. Isolator enclosed in weather proof panel complete with cabling &
earthing shall be included. Tower shall be selected on the basis of water
temperature in of 97.50F & water temp. out of 900F, ambient wet bulb temp.
of 830F. The Cooling Tower shall be complete in all respect with level
switch,Thermostatic control (for switching off the fan motor during low
ambient wet bulb temperature) and associated wiring as per specifications and
the capacity of each Cooling tower shall be as follows:

Capacity: To Cool 2800 USGPM of water at parameters indicated above Nos. 1133816 6 6802896
Suggested Motor capacity for each CT:40 HP

4 Hot Water Generator


Supply, installation, testing & commissioning of Hot Water Generator
complete in all respect with all accessories and mountings as per
specifications

4.1 Capacity : 400 KW For General Areas Nos. 517499 5 2587495


(1 No. Hot Water Genrator Standby include in above quantity)
4.2 Capacity: 20 KW for OTs Nos. 87732 2 175464
Water temp in at 450 C & temp. out at 550 C

TOTAL HIGH SIDE A 0 122703658


Rate (Rs.) Quantity Amount
S.N. Description Unit Remarks
DSR NON DSR DSR NON DSR
Section B - Low Side

1 Air Handling Units


Supply, installation, testing and commissioning of double skin modular construction, draw

through Ceiling Suspended (CS) / Floor Mounted Horizontal type (FM) Air Handling Units of

0.6 mm thick Plain GSS Sheet from inside & 0.6 mm thick Preplasticized GSS Sheet from

Outside. AHU Shall be complete with DIDW Centrifugal fan, Squirrel cage induction motor,

cooling coil (Copper tubes and Aluminium fins), pre-filter (Washable Synthetic fibre of

efficiency 90% down to 20 micron), drain pan, V belt drive, fireproof double canvass

connection and other accessories as per specifications (except water shut off valves, drain

piping, Thermometer and pressure gauges which are covered under separate item). Quoted

price shall include starter, cabling, wiring, conduiting, cable tray etc. Motor shall be suitable

for 415 ± 10% volts, 50 cycle, 3 Phase AC supply as indicated below.


Sl. No. AHU CFM (TYPE)

1.1 22000 (FM) Nos. 490128 2 980256


1.2 21000 (FM) No. 483138 14 6763932
1.3 18000 (FM) Nos. 441255 2 882510
1.4 17500(FM) Nos. 391884 8 3135072
1.5 17500(FM) Nos. 399020 4 1596080
1.6 16500(FM) Nos. 391156 8 3129248
1.7 15500 (FM) No. 320231 10 3202310
1.8 15000(FM) Nos. 323158 4 1292632
1.9 15000(FM) Nos. 316459 7 2215213
1.10 14700 (FM) No. 314857 3 944571
1.11 14500 (FM) Nos. 313838 4 1255352
1.12 14000 (FM) Nos. 311216 2 622432
1.13 13700 (FM) Nos. 309614 1 309614
1.14 13500(FM) Nos. 308595 4 1234380
Rate (Rs.) Quantity Amount
S.N. Description Unit Remarks
DSR NON DSR DSR NON DSR
1.15 13500(FM) Nos. 314711 1 314711
1.16 12200 (FM) Nos.
1.17 12000(FM) Nos. 256838 7 1797866
1.18 10000 (FM) Nos. 245041 6 1470246
1.19 9000(FM) Nos. 210671 1 210671
1.20 8600 (FM) Nos. 234118 2 468236
1.21 8500(FM) Nos. 207904 4 831616
1.22 7000(CS) Nos.
1.23 6000(CS) Nos. 148429 2 296858
1.24 5500(CS) Nos. 141729 7 992103
1.25 5000(FM) Nos. 141016 4 564064
1.26 5000(CS) Nos. 141016 3 423048
1.27 5000(CS) Nos. 122666 17 2085322
1.28 4500(FM) Nos.
1.29 4500(CS) Nos.
1.30 4200(FM / CS) Nos. 118199 2 236398
1.31 4000(FM / CS) Nos. 117179 10 1171790
1.32 3500(CS) Nos. 101596 2 203192
1.33 3200(CS) Nos. 99994 5 499970
1.34 3000(FM) Nos.
1.35 3000(CS) Nos.
1.36 2800(CS) No. 94897 7 664279
1.37 2500(CS) Nos. 81644 10 816440
1.38 2200(CS) Nos. 78018 4 312072
1.39 2000(CS) Nos. 73649 2 147298
1.40 1800(CS) Nos. 72630 7 508410
1.41 1500(CS) Nos. 69280 18 1247040
Rate (Rs.) Quantity Amount
S.N. Description Unit Remarks
DSR NON DSR DSR NON DSR
2 Air Handling Units for OTs and ICUs
Supply, installation, testing and commissioning of double skin modular construction, draw

through Sectional, Air Handling Units consisting of 0.8 mm Thick al/ss sheet inside and 0.6

mm thick preplastisized GSS Sheet from outside. AHU Shall be complete with imported

DIDW Backward curved Centrifugal fan, Squirrel cage induction motor with VFD, cooling coil

(Copper tubes and Aluminium fins 12-13 fin./inch), Heating Coil, pre-filter (Washable

Synthetic fibre of efficiency 90% down to 10 micron), Filter frame Flange type, drain pan, V

belt drive, fireproof double canvass connection and other accessories as per specifications

(except water shut off valves, drain piping and pressure gauges which are covered under

separate item). Quoted price shall include starter, cabling, wiring, conduiting, cable tray etc.

Motor shall be suitable for 415 ± 10% volts, 50 cycle, 3 Phase AC supply as indicated below.

AHU shall include the cost of fine and HEPA filter. Fine & HEPA Filters shall be installed in

the Double skin plenum above AHU.


Sl. No. AHU CFM (TYPE)
2.1 2600 (FM) No. 372916 6 2237496
2.2 4000 (FM) Nos. 404263 2 808526
2.3 3500 (FM) Nos. 378529 6 2271174
2.6 11500 (FM) Nos. 644281 2 1288562

3 Treated Fresh Air


Rate (Rs.) Quantity Amount
S.N. Description Unit Remarks
DSR NON DSR DSR NON DSR
The AHU shall be of double skin construction complete with filter, cooling coil and constant

volume supply air fan sections.The unit shall be of uniform cross section throughout and free

standing type.Construction shall be prefabricated individual framed sections bolted together

with neoprene gaskets between to make a complete unit.All AHU's shall be Horizontal Floor

Mounted type. The AHU casing to have a "Penta-Post" perimeter frame with wholly be easily

removable.Formed from galvanised sheet externally powder coated, rigidly reinforced with

50mm thick foam or fibreglass insulation. The outer skin of casing panels shall be of

minimum 1.0mm thick galvanised steel sheet and the internal skin shall be of minimum

0.8mm thick galvanised steel sheet. All air handling units shall include thermal breaks on

casing framework,and wherever required to prevent condensation on the casing.Thermal

breaks shall be in the form of profiled rubber inserts between internal and external surfaces.

Quoted price shall include starter, cabling, wiring, conduiting, cable tray etc.

Sl. No. TFA CFM (TYPE)

3.1 23500 (FM) No. 633872 1


3.2 21500 (FM) No. 590909 1

4 Variable Frequency Drive (VFD)


Variable Frequency Drive (VFD) with transducers, control wiring etc. as per specifications
and drawings.
4.1 15 HP Nos. 122985 28 3443580
4.2 12.5 HP Nos. 122985 5 614925
4.3 10 HP Nos. 91604 51 4671804
4.4 7.5 HP Nos. 88174 13 1146262
4.5 5 HP Nos. 77458 25 1936450
4.6 3 HP Nos. 62426 35 2184910
4.7 2 HP Nos. 54801 14 767214
4.8 1.5 HP Nos. 48957 23 1126011
4.9 1.0 HP Nos. 47730 18 859140
Rate (Rs.) Quantity Amount
S.N. Description Unit Remarks
DSR NON DSR DSR NON DSR

Section B- Low Side


5 Fan Coil Units (Ceiling Suspended type)
Supply, installation, testing and commissioning of ceiling suspended
type fan coil units complete with fan motor, cooling coil, filter plenum
with filters, supports, etc. as per specifications and drawings

5.1 1400 CFM (3.5 TR) Nos. 24118.00 2 48236


5.2 1200 CFM (3.0 TR) Nos. 21367.00 18 384606
5.3 1000 CFM (2.5 TR) Nos. 19214.00 5 96070
5.4 800 CFM (2.0 TR) Nos. 17659.00 24 423816
5.5 600 CFM (1.5 TR) Nos. 15985.00 39 623415
5.6 400 CFM (1.0 TR) Nos. 14789.00 1 14789

6 Fan Coil Unit Controls


Supply, installation, testing and commissioning of controls for fan coil
units consisting of 2-way motorized spring return valves, wiring etc.
6.1 Water Flow Rate 8.4 GPM Nos. 2712.00 2 5424
6.2 Water Flow Rate 7.2 GPM Nos. 2712.00 18 48816
6.3 Water Flow Rate 6.0 GPM Nos. 2712.00 5 13560
6.4 Water Flow Rate 4.8 GPM No. 2712.00 24 65088
6.5 Water Flow Rate 3.6 GPM No. 2500.00 39 97500
6.6 Water Flow Rate 2.4 GPM Nos. 2500.00 1 2500

7 Inline Fans for Ventilation


Supply, installation, testing and commissioning of inline ducted Fans
as shown in drawings. Fan motor shall be suitable for single phase, 50
Hz AC supply. The capacity of the fan given as under:-

7.1 Air Quantity 2300 CFM


Static Pressure : 25 mm
Motor Rating : 750 Watt. No 31427.00 10 314270

7.2 Air Quantity 2050 CFM


Static Pressure : 25mm
Motor Rating : 750 Watt. No. 24299.00 3 72897

7.3 Air Quantity 2000 CFM


Static Pressure : 25mm
Motor Rating : 750 Watt. No. 24299.00 10 242990
Rate (Rs.) Quantity Amount
S.N. Description Unit Remarks
DSR NON DSR DSR NON DSR

7.4 Air Quantity 1900 CFM


Static Pressure : 25mm
Motor Rating : 750 Watt. Nos. 24299.00 2 48598

7.5 Air Quantity 1600 CFM


Static Pressure : 25mm
Motor Rating : 750 Watt. No. 22114.00 3 66342

7.6 Air Quantity 1400 CFM


Static Pressure : 25mm
Motor Rating : 750 Watt. No. 22114.00 7 154798

7.7 Air Quantity 1275 CFM


Static Pressure : 20mm
Motor Rating : 500 Watt. No. 22114.00 16 353824

7.8 Air Quantity 1100 CFM


Static Pressure : 20mm
Motor Rating : 500 Watt. No. 22114.00 22 486508

7.9 Air Quantity 1050 CFM


Static Pressure : 25 mm
Motor Rating : 500 Watt. No. 22114.00 14 309596

7.10 Air Quantity 1000 CFM


Static Pressure : 24 mm
Motor Rating : 500 Watt. No

7.11 Air Quantity : 900 CFM


Static Pressure : 20 mm
Motor Rating : 300 Watt. No 20512.00 22 451264

7.12 Air Quantity: 800 CFM


Static Pressure : 20mm
Motor Rating : 300 Watt. No. 20512.00 21 430752

7.13 Air Quantity 700 CFM


Static Pressure : 15mm
Motor Rating : 300 Watt. No. 13820.00 10 138200

7.14 Air Quantity 600 CFM


Rate (Rs.) Quantity Amount
S.N. Description Unit Remarks
DSR NON DSR DSR NON DSR
Static Pressure : 15mm
Motor Rating : 300 Watt. No. 13820.00 4 55280

7.15 Air Quantity 650 CFM


Static Pressure : 20mm
Motor Rating : 300 Watt. No. 13820.00 8 110560

7.16 Air Quantity 550 CFM


Static Pressure : 20mm
Motor Rating : 300 Watt. No. 13820.00 7 96740

7.17 Air Quantity 500 CFM


Static Pressure : 20mm
Motor Rating : 300 Watt. No. 13820.00 20 276400

7.18 Air Quantity 400 CFM


Static Pressure : 10mm
Motor Rating : 150 Watt. No. 11126.00 13 144638

7.19 Air Quantity 375 CFM


Static Pressure : 10mm
Motor Rating : 150 Watt. No.

7.20 Air Quantity 350 CFM


Static Pressure : 20mm
Motor Rating : 300 Watt. No. 10241.00 12 122892

7.21 Air Quantity 300 CFM


Static Pressure : 10mm
Motor Rating : 150 Watt. No. 10241.00 10 102410

7.22 Air Quantity 250 CFM


Static Pressure : 10 mm
Motor Rating : 150 Watt. No 9896.00 4 39584

7.23 Air Quantity 200 CFM


Static Pressure : 10 mm
Motor Rating : 150 Watt. No 6910.00 17 117470

7.24 Air Quantity 150 CFM


Static Pressure : 25 mm
Motor Rating : 750 Watt. No 6910.00 11 76010
Rate (Rs.) Quantity Amount
S.N. Description Unit Remarks
DSR NON DSR DSR NON DSR

7.25 Air Quantity 100 CFM


Static Pressure : 5mm
Motor Rating : 60 Watt. No. 6692.00 20 133840

7.26 Air Quantity 75 CFM


Static Pressure : 20mm
Motor Rating : 300 Watt. No. 6692.00 13 86996

8 Air washer - single skin


Supply, installation, testing and commissioning of Single skin Air
washer unit with 200 mm thick impregnated cellulose paper media
(Celdek pads) of imported Origin (Munter's make) of minimum 90%
efficiency, factory assembled, distribution header, GI 'B' class piping,
makeup, quickfill and drain connections, Butterfly/Gate valves for
Pumps, make up, drain & quickfill connections of Sump, 2 Nos. pumps
of suitable capacity (1W +1 S), Y strainers and necessary fittings etc..
The quoted price shall also include GI frame and supporting structure
for Celdek pads, washable synthetic fibre filters (of 90% efficiency
down to 10 micron) and SS(16 gauge) sump,TEFC Motor (IP:55)
Control panel complete with necessary Switchgear, Starters, metering,
power and control wiring between Control panel and Motor/Pump etc.
& drive unit complete with Pulley, Belts, Fresh air Louvers with bird
screen (GI Construction) etc as per specification.

8.1 Duty: DG Room


Air Qty : 60,000 CFM
Static Pressure : 50 mm wg
Fan Motor HP : 30 HP(Suggested)
Pump Motor HP : 2.0 (Suggested) Nos. 786316.00 6 4717896

9 Axial Flow Fans


Rate (Rs.) Quantity Amount
S.N. Description Unit Remarks
DSR NON DSR DSR NON DSR
Supply, installation, testing and commissioning of direct driven Axial
Flow Fans as shown in drawings and as per specifications. Each fan
shall be complete with totally enclosed fan cooled motor (IP:55), motor
mount and vibration isolators. Fan motor shall be suitable for 3
Phase, 415 +/- 10% V, 50 Hz AC supply.(Motor speed shall not
exceed 1440 rpm).

9.1 Duty : Parking exhaust


Air Quantity : 40500 CFM
Static Pressure : 20 mm wg
Motor Rating : 15 KW (Suggested) Nos. 134448.00 4 537792
9.2 Duty : DG exhaust
Air Quantity : 40000 CFM
Static Pressure : 25 mm wg
Motor Rating : 15 KW (Suggested) Nos. 114059.00 9 1026531
9.3
Duty : CSSD Exhaust, Kitchen Exhaust & smoke extraction

Air Quantity :13600 CFM


Static Pressure : 25 mm wg
Motor Rating : 5.5 KW (Suggested) Nos. 54400.00 27 1468800
9.4 Duty : Store Exhaust & Smoke extraction
Air Quantity :5700 CFM
Static Pressure : 20 mm wg
Motor Rating : 1.5 KW (Suggested) Nos. 37914.00 25 947850
9.5 Duty : Kitchen Exhaust
Air Quantity :4600 CFM
Static Pressure : 20 mm wg
Motor Rating : 1.5 KW (Suggested) Nos. 37914.00 36 1364904
9.6 Duty : Kitchen Exhaust
Air Quantity :4000 CFM
Static Pressure : 10 mm wg
Motor Rating : 1.5 KW (Suggested) No. 37914.00 10 379140

10 Propeller Fans
Supply, installation, testing and commissioning of direct driven
Propeller fans for exhaust air as shown on drawings and as per
specifications. Each fan shall be complete with permanent split
capacitor or shaded pole motor, mounting plate, accessories like wire
guard, bird screen and fixed louvers for weather protection as
required. Fan capacities and Electrical characteristics shall be as
follows:
Rate (Rs.) Quantity Amount
S.N. Description Unit Remarks
DSR NON DSR DSR NON DSR
10.1 Duty : Exhaust
Air Quantity : 3,000 CFM
Motor Rating : 750 watt Nos. 5169.00 12 62028
10.2 Duty : Exhaust
Air Quantity :2300 CFM
Motor Rating : 500 Watt. Nos.
10.3 Duty : Exhaust
Air Quantity :2000 CFM
Motor Rating : 500 Watt. Nos. 5169.00 6 31014
10.4 Duty : Exhaust
Air Quantity :1500 CFM
Motor Rating : 500 Watt. Nos. 5169.00 13 67197
10.5 Duty : Exhaust
Air Quantity :1100 CFM
Motor Rating : 300 Watt. Nos. 4516.00 16 72256
10.6 Duty : Exhaust
Air Quantity :500 CFM
Motor Rating : 200 Watt. Nos. 3574.00 6 21444
10.7 Duty : Exhaust
Air Quantity :350 CFM
Motor Rating : 100 Watt. Nos. 3318.00 4 13272

11 Fan Section
Supply, Installation, Testing and commissioning of Single skin Fan
Section as shown in drawing and as per specifications. Each unit
shall be complete with casing (16G) DIDW centrifugal fan, belt drive,
motor, louvers etc. The quoted price shall include cost of starter,
wiring and cabling from electrical panel to unit with conduit/ cable tray.
Fan motor shall be suitable for 3 Phase, 415 ± 10% V, 50 Hz AC
supply
11.1 Duty : Toilet Exhaust
Air Quantity : 16000 CFM
Static Pressure : 40 mm wg
Motor Rating : 7.5 KW No. 257916.00 1 257916
11.2 Duty : Toilet Exhaust
Air Quantity : 8000 CFM
Static Pressure : 40 mm wg
Motor Rating :3.7 KW No. 161018.00 1 161018
11.3 Duty :Lift Pressurization
Air Quantity : 19200 CFM
Static Pressure : 40 mm wg
Rate (Rs.) Quantity Amount
S.N. Description Unit Remarks
DSR NON DSR DSR NON DSR
Motor Rating : 7.5 KW Nos. 329620.00 4 1318480
11.4 Duty :Lift Pressurization
Air Quantity : 12800 CFM
Static Pressure : 40 mm wg
Motor Rating : 5.5 KW Nos. 183277.00 2 366554

11.5 Duty :Lift Pressurization


Air Quantity : 6400 CFM
Static Pressure : 40 mm wg
Motor Rating : 3.5 KW Nos.

11.6 Duty :Staircase Pressurization


Air Quantity : 6000 CFM
Static Pressure : 40 mm wg
Motor Rating : 3.7 KW Nos. 127116.00 7 889812
11.7 Duty :Liftwell Pressurization
Air Quantity : 11200 CFM
Static Pressure : 40 mm wg
Motor Rating :9.3 KW Nos. 172805.00 5 864025
11.8 Duty :Staircase Pressurization
Air Quantity : 5200 CFM
Static Pressure : 40 mm wg
Motor Rating : 3.7 KW Nos. 76300.00 5 381500

12 Centrifugal Fans

Supply, installation, testing and commissioning of Double inlet double


width centrifugal Fans as per specifications and as shown on
drawings. Each fan shall be complete with totally enclosed fan cooled
motor (IP:55), belt drive, pulley mounted on motor and fan shafts, belt
guard, motor mounts and vibration isolators. Fan motor shall be
suitable for 3 Phase, 415 ± 10% V, 50 Hz AC supply. The quoted
price shall include cost of starter, wiring and cabling from electrical
panel to unit with conduit/ cable tray. Fan capacities as indicated
below:

12.1 Duty : Car Parking Fresh air/ Exhaust


Air Quantity :52000 CFM
Static Pressure : 50 mm wg
Motor Rating : 23.7 KW (Suggested) Nos. 778139.00 15 11672085
Rate (Rs.) Quantity Amount
S.N. Description Unit Remarks
DSR NON DSR DSR NON DSR
12.2 Duty : Car Parking Fresh air and Exhaust
Air Quantity :22500 CFM
Static Pressure : 40 mm wg
Motor Rating : 7.0 KW (Suggested) Nos. 321325.00 7 2249275

12.3 Duty : Car Parking Fresh air and Exhaust


Air Quantity :54000 CFM
Static Pressure : 40 mm wg
Motor Rating : 15.0 KW (Suggested) Nos.

13 Expansion Tank

Providing and installation of expansion tank, fabricated out of 6 mm


thick M.S. plate construction, duly insulated as per the specifications
and shall be complete with 50mm dia outlets for system connection
and overflow, make up connection, overflow connection, drain
connection, drain valve, vent connections, valves and fittings as
required. Expansion tank shall be complete with insulation as per
specifications and drawings.

13.1 SIZE : 1000 mm X 1000 mm X 1000 mm (high) No. 37260.00 2 74520


14 Condenser Water Piping

Providing and fixing in position the following MS 'C' class pipes, cut to
required length and installed with welded joints, providing and fixing
all necessary fittings such as bends, elbows, tees, reducers, flanges,
sockets etc as required and conforming to the specifications.

14.1 700 mm dia MS Pipes RMT 7282.00 225 1638450


14.2 500 mm dia MS Pipes RMT
14.3 400 mm dia MS Pipes RMT 3125.00 285 890625
14.4 200 mm dia MS Pipes RMT 1663.00 120 199560
14.5 100 mm dia MS Pipes RMT 670.00 140 93800
14.6 50 mm dia MS Pipes RMT 284.00 140 39760

Providing and fixing in position the butterfly valves as per specification


15
of following sizes:
15.1 400 mm dia Nos. 68342.00 28 1913576
15.2 200 mm dia Nos.
15.3 100 mm dia Nos.
15.4 50 mm dia Nos. 2259.00 18 40662
Rate (Rs.) Quantity Amount
S.N. Description Unit Remarks
DSR NON DSR DSR NON DSR
Providing and fixing in position the following balancing valves as per
16
specifications:
16.1 400 mm dia Nos. 171534.00 7 1200738

Providing and fixing in position the Check (Non return) valves as per
17
specifications of following sizes:
17.1 400 mm dia Nos. 93843.00 7 656901

Providing and fixing of Y strainer as per specifications of following


18
sizes:
18.1 400 mm dia Nos. 69686.00 7 487802

Providing and fixing in position the following Flexible coupling (with


19
conrtol rods) for the condenser water pumps.
19.1 400 mm dia Nos. 18343.00 28 513604

20 (CHILLED WATER / DRAIN)


20.1 CHILLED WATER PIPING-A

Providing and fixing MS pipes 'C' class cut to required lengths and
installed with all welded joints, insulation, aluminium cladding with 26
gauge, providing and fixing in position necessary fittings like bends,
elbows, tees, reducers, sockets, flanges etc fabricated to site as per
specifications.

20.1.1 700 mm dia MS Pipes RM 10186.00 220 2240920


20.1.2 600 mm dia MS Pipes RM 8930.00 376 3357680
20.1.3 500 mm dia MS Pipes RM 6071.00 515 3126565
20.1.4 450 mm dia MS Pipes RM 5320.00 200 1064000
20.1.5 400 mm dia MS Pipes RM 4649.00 150 697350
20.1.6 350 mm dia MS Pipes RM
20.1.7 300 mm dia MS Pipes RM 4229.00 256 1082624
20.1.8 250 mm dia MS Pipes RM 3701.00 200 740200
20.1.9 200 mm dia MS Pipes RM 2530.00 120 303600
20.1.10 150 mm dia MS Pipes RM 1679.00 250 419750

20.2 CHILLED WATER PIPING-B


Rate (Rs.) Quantity Amount
S.N. Description Unit Remarks
DSR NON DSR DSR NON DSR
Providing and fixing MS pipes heavy class cut to required lengths and
installed with all welded joints, providing and fixing in position
necessary fittings like bends, elbows, tees, reducers, sockets, flanges
etc fabricated to site and insulated TF quality thermocoal pipe section
as per specifications and drawings.

20.2.1 500 mm dia MS Pipes RM 5546.00 81 449226


20.2.2 450 mm dia MS Pipes RM 5008.00 210 1051680
20.2.3 400 mm dia MS Pipes RM 4368.00 270 1179360
20.2.4 350 mm dia MS Pipes RM 4346.00 90 391140
20.2.5 300 mm dia MS Pipes RM 4023.00 150 603450
20.2.6 250 mm dia MS Pipes RM 3444.00 570 1963080
20.2.7 200 mm dia MS Pipes RM 2318.00 550 1274900
20.2.8 150 mm dia MS Pipes RM 1523.00 850 1294550
20.2.9 125 mm dia MS Pipes RM 1302.00 900 1171800
20.2.10 100 mm dia MS Pipes RM 1087.00 2000 2174000
20.2.11 80 mm dia MS Pipes RM 829.00 2320 1923280
20.2.12 65 mm dia MS Pipes RM 707.00 2160 1527120
20.2.13 50 mm dia MS Pipes RM 577.00 2500 1442500
20.2.14 40 mm dia MS Pipes RM 475.00 2220 1054500
20.2.15 32 mm dia MS Pipes RM 432.00 1800 777600
20.2.16 25 mm dia MS Pipes RM 374.00 2100 785400
20.2.17 20 mm dia MS Pipes RM 340.00 800 272000

21 Providing and fixing in position the following butterfly valves duly


insulated as per specifications and drawings

21.1 500 mm dia Nos 117815.00 4 471260


21.2 300 mm dia Nos 32247.00 44 1418868
21.3 150 mm dia Nos 5322.00 2 10644
21.4 125 mm dia Nos 5249.00 24 125976
21.5 100 mm dia Nos 4176.00 70 292320
21.6 80 mm dia Nos 2895.00 72 208440
21.7 65 mm dia Nos. 2583.00 122 315126
21.8 50 mm dia Nos. 2406.00 104 250224
21.9 40 mm dia Nos. 2206.00 98 216188
21.10 32 mm dia Nos. 2057.00 72 148104

22 Providing and fixing in position the following balancing valves duly


insulated as per specifications and drawings

22.1 300 mm dia Nos 97344.00 8 778752


Rate (Rs.) Quantity Amount
S.N. Description Unit Remarks
DSR NON DSR DSR NON DSR
22.2 125 mm dia Nos 23360.00 12 280320
22.3 100 mm dia Nos 16856.00 30 505680
22.4 80 mm dia Nos 9313.00 36 335268
22.5 65 mm dia Nos 8658.00 61 528138
22.6 50 mm dia Nos 5622.00 47 264234
22.7 40 mm dia Nos. 3421.00 44 150524
22.8 32 mm dia Nos. 2814.00 36 101304

23 Providing and fixing in position the following Y strainer duly insualted


as per specifications and drawings
23.1 300 mm dia Nos 42096.00 14 589344
23.2 125 mm dia Nos 8764.00 1 8764
23.3 100 mm dia Nos 6625.00 14 92750
23.4 80 mm dia Nos. 4966.00 27 134082
23.5 65 mm dia Nos. 3753.00 59 221427
23.6 50 mm dia Nos. 3420.00 46 157320
23.7 40 mm dia Nos. 3156.00 46 145176
23.8 32 mm dia Nos. 3143.00 36 113148

24 Providing and fixing in position the following Ball Valves with Strainer
24.1 duly
25 mminsulated
dia as per specifications and drawings Sets 2660.00 40 106400
24.2 20 mm dia Sets 1207.00 40 48280

25 Providing and fixing in position the following Ball Valves without


strainer duly insulated as per specifications and drawings

25.1 25 mm dia Sets 1500.00 40 60000


25.2 20 mm dia Sets 962.00 40 38480

26 2-way butterfly motorized valve ONN/OFF with BMS compatible with/


without insulation.
26.1 700 mm dia Valve Nos. 743125.00 2 1486250
26.2 400 mm dia Valve Nos. 219414.00 19 4168866
26.3 300 mm dia Valve Nos. 89837.00 7 628859
26.4 150 mm dia Valve Nos.

27 Providing and fixing in position industrial type pressure gauges with Nos. 862.00
Gun metal, stainless steel syphon & ball valve and necessary fittings,
544 468928
for the ease of maintenance and operation as per specifications and
drawings.
Rate (Rs.) Quantity Amount
S.N. Description Unit Remarks
DSR NON DSR DSR NON DSR
28 Providing and fixing in position stem type mercury-in-glass filled Nos. 729.00
496 361584
industrial thermometers

29 Supply, installation, testing and commissioning of 2-way motorized


valves suitable for Chilled water as well as hot water application
complete with Electrical/Electronic actuator, necessary wiring and
required accessories for proper operation and control of valves of
following sizes. (Vendor to submit the Selection sheets of the Control
Valves for all sizes individually)
29.1 100 mm dia Nos. 93518.00 1 93518
29.2 65 mm dia Nos. 37655.00 38 1430890
29.3 50 mm dia Nos. 22683.00 59 1338297
29.4 40 mm dia Nos. 20960.00 46 964160
29.5 32 mm dia Nos. 18604.00 43 799972
29.6 25 mm dia Nos. 18105.00 40 724200

30 Supply, installation, testing and commissioning of cooling thermostats


for various Air Handling Units and Fan Coil Units as per specifications
including all accessaries ,mountings,wiring between thermostat & unit,
terminations etc.
30.1 Proportional thermostats for Air Handling Units Nos. 5117.00 212 1084804
30.2 Snap acting thermastates for Fan Coil Units Nos. 2705.00 89 240745

31 Providing and fixing in position the following Drain Valves (For Drain)

duly insulataed as per specifications and drawings


31.1 25 mm dia Nos. 1470.00 372 546840
31.2 20 mm dia Nos. 936.00 233 218088

32 Providing and fixing in position the following Purge Valves duly


insulataed as per specifications and drawings
32.1 25 mm dia Nos. 1348.00 50 67400
32.2 20 mm dia Nos. 1170.00 240 280800

33 Providing and fixing in position the following descaling valves for


condensing units as per specification.
33.1 32 mm dia Valve Nos. 2944.00 28 82432
Rate (Rs.) Quantity Amount
S.N. Description Unit Remarks
DSR NON DSR DSR NON DSR
34 Providing and fixing of Water Flow Switch Nos. 1381.00 28 38668

35 Auto air vents of following size


35.1 15 mm dia. Nos. 1013.00 30 30390

36 DRAIN PIPING
Providing and fixing in position the following GI medium class cut to
required length and installed with screw joints including the necessary
fittings (bends, tees, unions, sockets etc) duly insulated with 25 mm
thick TF quality thermocole pipe section as per specifications.
36.1 50 mm dia RMT 449.00 1220 547780
36.2 40 mm dia RMT 362.00 1740 629880
36.3 25 mm dia RMT 263.00 3430 902090

37 Air Distribution
Supply, fabrication, installation and testing of G.I. sheet metal ducts
factory fabricated as per SMACNA in accordance with the approved
shop floor drawing complete with all accessories, bends, fittings,
specials, chutes, vanes, necessary supports and joint/flange in sealed
with 5 mm thick gasket & silicon sealant etc. as per specifications and
drawings.
37.1 0.63 MM (24 gauge) Galvanized Sheet Steel Ducting Sqm. 664.00
54819 36399816
37.2 0.8 MM (22 gauge) Galvanized Sheet Steel Ducting Sqm. 726.00
17956 13036056
37.3 1.0 MM (20 gauge) Galvanized Sheet Steel Ducting Sqm. 820.00
18885 15485700
37.4 1.25 MM (18 gauge) Galvanized Sheet Steel Ducting Sqm. 953.00
13373 12744469

38 Supply, fabrication, installation and testing of Aluminium ducts for OT's


in accordance with the approved shop floor drawing complete with all
accessories, bends, fittings, specials, chutes, vanes, necessary
supports etc. as per specification.

38.1 20 gauge Aluminium Ducting Sqm. 2000.00 1750 3500000

39 Laminar Flow Diffuser


Rate (Rs.) Quantity Amount
S.N. Description Unit Remarks
DSR NON DSR DSR NON DSR
Supply, Installation, Testing and commissioning of laminar flow
plenum as per drawing and specification. Plenum shall be of
precoated GI sheets and openable from front and shall be made of 18
gauge Aluminium. It shall be insulated and have Aluminium volume
control damper on each entry level. It shall have Aluminium perforated
grills for air outlets.

39.1 Size: 900 x 600 mm Nos. 14295.00 108 1543860

40 Supply, installation and testing of multiblade box type Galvanized Sqm. 9823.00
Sheet Steel construction damper for ducts to be provided with suitable 312 3064776
links and quadrants for control of volume of air.

41 Supply,installation,testing and balancing of square shape ceiling

diffusers with removable core.


41.1 Extruded aluminium construction, powder coated with volume control Sqm.

damper for supply air.


41.2 Extruded aluminium construction, powder coated without volume Sqm.

control damper for return/ exhaust air.

42 Supply, installation, testing and commissioning of extruded aluminium


powder coated supply / return air grills of approved shade and make
as per specifications including any framework required for fixing of
grills.

42.1 Extruded aluminium construction, powder coated with volume control Sqm. 12400.00
65 806000
damper for supply air.
0
42.2 Extruded aluminium construction, powder coated without volume Sqm. 7320.00
150 1098000
control damper for return/ exhaust air.
Rate (Rs.) Quantity Amount
S.N. Description Unit Remarks
DSR NON DSR DSR NON DSR
43 Supply, installation, testing and commissioning of extruded aluminium
powder coated linear grills of approved shade and make as per
specifications including any framework required for fixing of linear
grilles.
43.1 150 mm wide Linear Grilles Rmt. 1039.00
600 623400
43.2 100 mm wide Linear Grilles Rmt. 732.00
63 46116

Supply, installation, testing and commissioning of volume control Sqm. 4727.00


44 10 47270
damper of Anodised Aluminum material for grills.

45 Supply, installation and balancing of extruded aluminium powder


coated fresh / exhaust air louvers complete with aluminium wire mesh
birdscreen.
45.1 Fresh air louvers with VCD. Sqm. 13688.00
65 889720
45.2 Exhaust air louvers(without volume control dampers) Sqm. 8682.00
151 1310982

46 Supply, installation, testing and commissioning of extruded M.S.


powder coated exhaust air grills of approved shade and make

46.1 Single Louvered Supply air grills with dampers. Sqm.


46.2 Single Louvered exhaust air grills without dampers. Sqm. 5039.00 145 730655

47 Fire Dampers
47.1 Providing and fixing of motorised combination fire & smoke dampers Sqm. 13661.00
of approved make of atleast 90 minutes fire rating and as per the
specifications. The fire damper shall be complete with electronic
292 3989012
temperature sensor and electrically operated actuator. The fire
damper shall be located in the supply / return air ducts. The control
panel will be such located that the reset can be done easily.
Accessories for fire dampers
47.2 Control panel actuator, including spring type actuator with smoke Nos. 16104.00
sensor and remote indication of fire damper position. 760 12239040

48 Insulation
Rate (Rs.) Quantity Amount
S.N. Description Unit Remarks
DSR NON DSR DSR NON DSR
Supply, Installation, Testing & Commissioning of external thermal
insulation with closed cell cross-linked polythelene foam with self
adhesive and density for insulation of ducts as per specifications &
drawings.
48.1 20 mm thick (For insulation in Non conditioned space) Sqm. 767.00
2060 1580020
48.2 12 mm thick (For insulation in Air-conditioned space) Sqm. 544.00
60000 32640000

49 Supply and fixing of Acoustic lining inside the ducts with fibre glass as
per specifications and as shown on drawings.
49.1 25 mm thick Sqm. 1200.00
5250 6300000

50 Supply and fixing of Acoustic lining inside the AHU rooms with fibre
glass as per specifications and as shown on drawings.

50.1 50 mm thick (32 kgs / cum) Sqm. 1500.00 9950 14925000

51 Supply and fixing of underdeck insulation with expanded polystyrene


as per specifications and drawings.
51.2 50 mm thick Sqm. 499.00 13570 6771430

Total HVAC B1+B2 0 336450331


Balance work for Construction of ESIC Medical College and Hospital at Bihta ,Patna(Bihar)

SUMMARY OF LIFT

SUB
DESCRIPTION NON DSR
HEAD

1 Lifts 43,958,200.00

Total 43,958,200.00
Balance work for Construction of ESIC Medical College and Hospital at Bihta ,Patna(Bihar)

ESTIMATE OF LIFTS
Quantity Ampount
S.No. Description & Type of Lifts Unit Rate NON Remarks
DSR DSR NON DSR
DSR
1 Passenger elecators
1.1 Supply Installation testing and commissioning of passenger elevotors as per specification
a) Passenger elecators- with 2 stops & 1.0 MPS speed (Passenger : 13 Nos/844 kgs)about 3.2 Meters NOS

b) Passenger elecators- with 6 stops & 1.0 MPS speed (Passenger : 13 Nos/844 kgs)about 16 Meters NOS

c) Passenger elecators- with 7 stops & 1.0 MPS speed (Passenger : 13 Nos/844 kgs)about 19.2 Meters NOS 1899800 2 3799600
d) Passenger elecators- with 8 stops & 1.0 MPS speed (Passenger : 13 Nos/844 kgs)about 22.4 Meters NOS 1971400 4 7885600
e) Passenger elecators- with10 stops & 1.0 MPS speed (Passenger : 13 Nos/844 kgs)about 28.8Meters NOS

2 BED Elevators

2.1
Supply Installation testing and commissioning of passenger elevotors as per specification

a) with 3 stops & 1.0 MPS speed (Passenger : 26 Nos/1768 kgs)about 16.4 Meters NOS

b) with 4 stops & 1.0 MPS speed (Passenger : 26 Nos/1768 kgs)about 9.6 Meters NOS

c) with stops & 1.0 MPS speed (Passenger : 26 Nos/1768 kgs)about 25.6 Meters NOS 3227300 10 32273000

Total 43958200
Balance work for Construction of ESIC Medical College and Hospital at Bihta ,Patna(Bihar)

SUMMARY SHEET (Pumps & Equipments)

S.No. DESCRIPTION OF SUB HEAD DSR NON DSR Total Amount

1 Pumps & Equipments 152,496.00 1,695,879.00 1,848,375.00

Total 152,496.00 1,695,879.00 1,848,375.00

Add 22% on DSR Items(NEW) 33,549.12 33,549.12

DSR Total 186,045.12 1,695,879.00 1,881,924.12


Balance work for Construction of ESIC Medical College and Hospital at Bihta ,Patna(Bihar)

Quantity Amount
Rate
S.N. Description Unit Remarks
(in Rs.) DSR NON DSR DSR NON DSR
1 2 3 4 5 6 7 8 9
1 Providing and fixing horizontal / vertical single/multistage
centrifugal pumping set with CI connections, SS impeller,
stainless steel shaft and induction motor mounted on common
base frame, vibration eleminating pads accessories complete as
per specifications. Motor to be suitable for 415 Volts

+ 10%, 3 phase 50 Hz. A/C supply.

a) Filter Feed Pumps (1W +1S)


Type of pump-Horizontal Multi-stage centrifugal pump with axial
suction port and radial discharge port with a three phase motor,
mounted on a common baseplate.
Location - Plant Room
Capacity - 3250LPM
Head - 35 M.
RPM - 2900 Each 0 -
-
b) Softner Feed Pumps (1W+1S) -
Capacity - 1200LPM -
Head - 35 M. -
RPM - 2900 Each 0 -
-
c) Domestic Transfer Pump(HYDO.) for Hospital -
Location - Plant Room (1W+1SB) -
Capacity - 275LPM. -
Head - 60 M. -
RPM - 2900 Set 0 -
-
d) Flushing water transfer PUMP(HYDO.)for hospital
-
Location - Plant Room (1W+1SB) -
Capacity - 370LPM. -
Head - 60 M. -
RPM - 2900 Set 0 -
-
e) DOMESTIC TRANSFER PUMP for other building -
Location - Plant Room (1W+1SB) -
Capacity - 335LPM. -
Quantity Amount
Rate
S.N. Description Unit Remarks
(in Rs.) DSR NON DSR DSR NON DSR

Head - 60 M. -
RPM - 2900 Set 0 -
-
f) Flushing water transfer PUMPfor other building -
Location - Plant Room (1W+1SB) -
Capacity - 475LPM. -
Head - 60 M. -
RPM - 2900 Set 0 -
-
g) Soft-Water Transfer Pumps (1W+1S) STP TO UGT -
Capacity - 670LPM -
Head - 50 M. -
RPM - 2900 Each 0 -
-
2 Submersible Drainage Sump Pumps (1W +1S) -
Sumersible drainage Pumps vertical stage S.S. pump with float
type controller automatic operation required flow rate per
hour,required head, submersible type, suitable for clear water
drainage & 38 mm solid handling capacity complete with motor,
control panel, submersible cable, built in suction strainer,
bottom support frame and dual plate type NRV’s as required. -

-
2.1 Location - Plant Room Sump (1w+1SB) -
Capacity - 100LPM -
Head - 10 M. -
RPM - 2900 Each 94,891.00 2 189,782.00
-
2.2 Location - HOSPITAL BASMENT DRAINAG (1w+1SB)
-
Capacity - 285LPM -
Head - 10M. -
RPM - 2900 Each - 0 -
-
2.3 Location - OTHER BASMENT DRAINAG (1w+1SB) -
Capacity - 100LPM -
Head - 10M. -
RPM - 2900 Each - 0 -
2.4 Location - R.W.Supply (1w+1SB) -
Capacity - 150LPM -
Quantity Amount
Rate
S.N. Description Unit Remarks
(in Rs.) DSR NON DSR DSR NON DSR

Head - 45M. -
RPM - 2900 Each 65,238.00 6 391,428.00
-
2.5 Location - SEWAGE SUMP (1w+1SB) -
Capacity - 100 LPM -
Head - 10M. -
RPM - 2900 Each 94,891.00 6 569,346.00
-
Note: -
a) The Motor HP to be confirmed by the manufacturer for the duty
mentioned for each pump alongwith performance characteristic
curve. -
-
b) The Motor of pumps shall be suitable for operation with variable
frequency drives system. -
-
3 The following Automation and instrumentation including supply,
installation, testing and commissioning of all sensors, relays,
level controller/switches, level indicators etc. Relays/Modules
and wiring for completely functional system.
-
a) For Automatic switching ON-OFF of following pumps: -
i) Raw water pumps from Level Controller (four level float type)
installed in Filter Water Tank. Each 6,500.00 4 26,000.00
ii) Tubewell pumps from Level Controller (four level float type)
installed in Raw Water Tank. Each 6,500.00 4 26,000.00
-
b) Dry Run Preventor for each of the above pumps by providing
Low level sensor in the three tank viz Raw Water tank, Filter
water tank and Soft water tank. -
-
c) Water Level Indicator -
i) Side mounted Magnetic float type with fluorescent indication
properly protected for Underground tank. Each 12,500.00 8 100,000.00
-
d) Flow switches for inter locking of Chlorine Dosing Pump with
Hydropneumatic filter water supply pump. Each 7,500.00 1 7,500.00
-
Note: -
Regulation of Pumps includes cut in, cut-outs, switching ON-
OFF pumps based on requirements. -
-
Quantity Amount
Rate
S.N. Description Unit Remarks
(in Rs.) DSR NON DSR DSR NON DSR

4 Providing and fixing cast iron dual plate type non-return value
(as per Technical specification) including nuts, bolts, 1.5mm
thick CAF gasket sheets complete in all respects (PN 1.6)
-

a) 40 NB
Each 1,800.00 4 7,200.00
-
5 Providing and fixing Pressure Reduce value from 6.kg/cm2 to
4kg/cm2 as per IS, including nuts and bolts complete in all
respects.
-
a) 32 dia Each 5,000.00 2 10,000.00
b) 40 dia Each 6,100.00 1 6,100.00
-
6 Providing and fixing standard dial type pressure gauge dia 100
mm with screwed inlet with isolation cock suitable for liquid
gauge to show pressure upto: Make - Guru
-
a) (0-5) KG/Sq.cm Each 850.00 4 3,400.00
b) (0-10) Kg/Sq.cm Each 850.00 4 3,400.00
-
7 Water Filtration Units -
a) The Multi-grad filter &Activated carbon filter shall be constructed
of M.S. material with inner shell of integrated polyethylene,
polypropylene and other material as per manufacturer's
standard.
The inter distribution system and the underbed draw off system
shall be of Hub & Lateral type of polypropylene material. The
filter shall be provide with manhole cover, hand hole, flanged
outlet for piping/valve connection and adequate tripod with skid
self supporting structure for making the installation completed.
The filter shall also be provided with vacuums breaking
connection / accessories to avoid any collapse of internal lining.
All filters shall be provided with lifting lugs and making the
installation completed as required. Flow Rate : 97.5.0 m3 / h
FOR 10 hr Rate of Flow not to be exceed : 98Cu.M/Hr/Sq. M.
of surface area

Set 0 -
-
8 Chemical Dosing Unit -
Quantity Amount
Rate
S.N. Description Unit Remarks
(in Rs.) DSR NON DSR DSR NON DSR

a) Medium pressure synchronous motor type chemical dosing


pump with noryl Plastic body and PVC parts, dispensing valves,
foot valves, relief valves, mounting plate, chemical tank of 100
litre capacity complete.
-
Capacity 0-6 LPH at pressure head of 40 MWC.. Set 0 -
-
9 Softerner Unit -
The filter shall be constructed of M.S. material with inner shell of
integrated polyethylene, polypropylene and other material as
per manufacturer's standard.
The inter distribution system and the underbed draw off system
shall be of Hub & Lateral type of polypropylene material. The
filter shall be provide with manhole cover, hand hole, flanged
outlet for piping/valve connection and adequate tripod with skid
self supporting structure for making the installation completed.
The filter shall also be provided with vacuums breaking
connection / accessories to avoid any collapse of internal lining.
All filters shall be provided with lifting lugs and making the
installation completed as required.With SS salt-saturator &
Moter.
Flow Rate :90.3 m3 / h for 10hr
Rate of Flow not to be exceed : 95 Cu.M/Hr/Sq. M. of surface
area

Set 1,001,908.00 0 -
-
10 Regeneration Tank/Salt Dilution Tank -
FRP construction of suitable capacity tank to store and measure
brine for regeneration of softening plant. Tank to be complete
with interconnecting MS/HDPE pipe and other assembly
required for commissioning. Salt Dilution Tank shall be provided
with structural support of suitable dimensions for proper
operating space at height of 1500mm.
-
a) Brine Measuring Tank - 1000 litres capacity Set 14,228.00 1 14,228.00
b) Salt Dilution Tank - 1000 litres capacity Set 10,000.00 1 10,000.00
-
11 Water Supply Panel -
A INCOMER -
i) 2Nos. 250A TP&N MCCB (25 KA) -
B METERING & INDICATION -
i) 2 sets of phase indicating lamps -
Quantity Amount
Rate
S.N. Description Unit Remarks
(in Rs.) DSR NON DSR DSR NON DSR

ii) 2 Nos. Voltmeter (0-500V) with Built-in VSS each with 3 nos. 2A
SP MCB -
iii) 2 sest Ammeter (0-160A) each with ASS and 3 nos.160/5A,
CT's -
C BUS COUPLER -
1 no. 250A TP&N MCCB (25KA) -
Interlocking- The Incomesr & Bus coupler shall be Electrically
& Mechanically Interlocked -
D BUS-BAR -
i) 2 Set of 300A TPN Aluminium Bus Bar with colour coded PVC
Sleeves -
E OUTGOINGS -
i) 2 nos. 125A TP MCCB (25 KA) -
ii) 5 Nos.63A TPN MCB -
iii) 4 Nos.40A TP MCB(10KA) C curve -
iv) 8 Nos. 16A / 32A TP MCB(10KA) C curve -
v) 2 sets of S/D starter with self illuminated Push button for ON &
OFF and suitable rating of contactor, SPPR and O/L relays,
suitable for 50 HP Motor.
-
vi) 4 sets of S/D starter with self illuminated Push button for ON &
OFF and suitable rating of contactor, SPRR and O/L relays,
suitable for 15 HP Motor. -
vii) 4 sets of DOL starter with self illuminated Push button for ON &
OFF and suitable rating of contactor, SPPR and O/L relays,
suitable for 7.5 HP Motor. -
viii) 2 sets of DOL starter with self illuminated Push button for ON &
OFF and suitable rating of contactor, SPPR and O/L relays,
suitable for 1.5 HP Motor. -
ix) 3 Nos. space for S/D or DOL starter -
x) Provision of providing float level controller for interlocking for
automatic operation alongwith Relays/Modules required for all
respective work as required in the control panel
-
Supply of Water Supply Panel as described above
Set 0 -
Receiving, fixing, testing & commissioning of Water Supply
Panel as described above Set 0 -
-
Note: -
Quantity Amount
Rate
S.N. Description Unit Remarks
(in Rs.) DSR NON DSR DSR NON DSR

1 The rating of all switchgear must match the HP of all pumps


quoted and 20% space for spare to be kept in the panel.
-
2 Item to be operated after confirmation from Project Manager
-
-
12 Electrical cable -
Power cabling including supply, laying of armoured cable, PVC
insulated, XLPE aluminium conductor, 1.1 KV of sizes as
mentioned below as per approved design/specifications.
-
i) 4C x 16 sq.mm Mtrs. 250.00 75 18,750.00
ii) 3C x 4 sq.mm Mtrs. 135.00 120 16,200.00
iii) 3C x 6 sq.mm Mtrs. - 0 -
iv) 3C x 10 sq.mm Mtrs. 190.00 800 152,000.00
v) 3C x 25 sq.mm Mtrs. 247.00 210 51,870.00
vi) 3C x 35 sq.mm Mtrs. 315.00 55 17,325.00
vii) 3C x 16 sq.mm Mtrs. 200.00 350 70,000.00
-
13 Supply and making end termination with brass compession
gland and aluminun lugs for following size of PVC insulated and
PVC sheathed/ XLPe aluminum conductor cable of 1.1 grade
required. -

. 3C x 4 /6 sq.mm / 4C x 16 sq.mm.
Nos 107.00 50 5,350.00
-
-
Total Non DSR Items (New Items)

DSR Items
25 Supply and making end termination with brass compession
gland and aluminun lugs for following size of PVC insulated and
PVC sheathed/ XLPe aluminum conductor cable of 1.1 grade
required. -
3C x 10 sq.mm (DSR2007 4.1.7 MVET)
i) Nos 102.00 18 1,836.00
3C x 25 sq.mm (DSR2007 4.1.9 MVET)
iii) Nos 128.00 30 3,840.00
3C x 35 sq.mm (DSR2007 4.1.10 MVET)
iv) Nos 125.00 6 750.00
-
26 Earthing work -
Quantity Amount
Rate
S.N. Description Unit Remarks
(in Rs.) DSR NON DSR DSR NON DSR

i) Providing and fixing of 6 SWG dia GI wire on surface or in


recess forr loop earthing as required. Mtrs. 24.00 250 6,000.00
(DSR2007 3.19 EARGIWRSUR) -
ii) Providing and fixing of 25x5mm GI strip on surfce or in recess
for connections etc. as required. Mtrs. 66.00 250 16,500.00
(DSR2007 3.19 EARGISTRSUR) -
27 Fabricating and installing following size of perforated MS cable
trays including horizontal and vertical bends, reducers, tees
cross members and others accessories as required and duly
suspended from the ceiling wih MS suspended and including
painting with powder coating etc. as required.

-
300 mm width X 50mm depth X 1.6mm thickness (DSR2007
i)
3.1.4 CBTR) Mtrs. 524.00 120 62,880.00
150 mm width X 50mm depth X 1.6mm thickness (DSR2007
ii)
3.1.2 CBTR) Mtrs. 335.00 75 25,125.00
100 mm width X 50mm depth X 1.6mm thickness (DSR2007
iii)
3.1.1 CBTR) Mtrs. 279.00 50 13,950.00
-
28 Supply, and fixing of 16 gauge, MS conduits in following sizes
including cost of junction boxes, bends, elbows, sockets, tees
and MS flexible conduit to connect from ceiling to false ceiling
etc. laying in slab, cutting chases and making good or surface
mounted including all fixing hardware.

-
i) 20 mm dia- (DSR-2007 1.20.1 STLCON) Mtrs. 77.00 125 9,625.00
ii) 25 mm dia- (DSR-2007 1.20.2 STLCON) Mtrs. 86.00 65 5,590.00
-
29
Supply and drawing following sizes of FR PVC insulated copper
conductor , single core cable in the existing surface/ recessed
steel/ PVC conduit as required. (DSR Item code :- 1.17 WGEC)
-
i) 1.17.3 3 x 1.5 sq.mm. 32.00 50 1,600.00
ii) 1.17.4 4 x 1.5 sq.mm. 38.00 50 1,900.00
iii) 1.17.7 7 x 1.5 sq.mm. 58.00 50 2,900.00
TOTAL of DSR Items 152,496.00 1,695,879.00
Balance work for Construction of ESIC Medical College and Hospital at Bihta ,Patna(Bihar)

SUMMARY SHEET OF HOT WATER BOILER

S.N. SECTIONS DSR NON DSR Amount

1 Hot Water Boiler 3,661,161.00 3,661,161.00

Total Cost (In Rupees) 3,661,161.00 3,661,161.00


Balance work for Construction of ESIC Medical College and Hospital at Bihta ,Patna(Bihar)

HOT WATER BOILER

Quantity Amount
S.N Description Rate Unit Remarks
DSR NON DSR DSR NON DSR
1 2 3 4 5 6 7 8 9
1 HOT WATER GENERATOR
a) Supplying, installing, testing and commissioning of MS
Vartical oil oprated type factory assembled hot water
generators consisting of two closely wound, helical,
concentric coils arranged to give three passes on flue
gas side made of ERW tubes. Hot water Generator
shall be capable on rated for delivery of 400,000
Kcal/hr with thermal efficiency 93+-2%, The unit sall be
well factory insulated as per standards. (Hot water
generators shall be IBR type).
754,164.00 Nos. 2 1,508,328.00
b) Hot water Circulation Pump -
Hot water primary Circulation pump, Centrifugal type
with mechanical seal having flow rate of 0--cubic mtr
per hr. . 87,845.00 Nos. 2 175,690.00
c) Secondary circulation pump of flow ...m3/hr, ...m head
with all valves, gauges and allied accessories.( 1 W +1
S) 87,845.00 Nos. 2 175,690.00
d) All interconnecting wiring / cabling between hot water
generator and electrical panel. -
e) The HWG shall have an in-built facility to start / stop
depending on variation in demand all different periods. -
-
2 HOT WATER TANK -
Quantity Amount
S.N Description Rate Unit Remarks
DSR NON DSR DSR NON DSR
Supply, installation, testing & commissioning of SS
horizontal hot water tank (Capacity 10000 Ltrs.)
suitable for 4 Kg/Scm Working pressure and test
pressure of 6 Kg/ Scm. The tank shall have shell
thickness of 6 mm and Dished end thickness of 8
mm.The tank shall consist all required accessories and
fittings like pressure reflief vlaves, pressured gauge at
inlet/outlet with isolation cock, thermometer at
inlet/outlet. The tank shall be duly insulated with
mineral wool 50mm thick, density 120 Kg/m3 . with
chicken wire mesh and aluminium cladding 24
SWG.the tank shall be mounted on M.S saddle. Tank
shall be fabricated with all necessary mountings and
accessories with valves and Provision for inlet / outlet,
drain, overflow, manhole, air vent system. Coil for heat
transfer inside the tank shall be fabricated from ERW
helical tubes with seamless bends. Tank shall be
supplied with temp controller,RTD,Air regulator
compensating cables with pre wired control panel.

-
Calorifier shall be supplied with required nogzzles
40/50 NB with valves for connecting main hot water
generators inlet and outlet, overhead tank, process
outlet process return line 0 -
-
3 BOILER PANEL AS PER MANUFACTURE -
a Incoming -
i) One (1) no. 160 Amps MCCB (20KA). -
ii) One (1) Set of phase indication lamps with fuses. -
One (1) No. of 0-200 Amps Ammeter with selector
iii)
switch. -
iv) One (1) no. 0-500 volts voltmeter with selector switch. -
b Bus Bars -
i) One (1) set of 400 Amps, TPN+E, 415 V, Aluminium
busbars. -
c Outgoing -
Quantity Amount
S.N Description Rate Unit Remarks
DSR NON DSR DSR NON DSR
i) 2 Nos. 32 A TP & N MCCB for fuel pumps (two
working, one standby). Each MCCB compartment shall
be equipped with suitable range ammeter, ameter
selector switch, separate single phasing preventor,
on/off/ trip indication lamps contorls, push button with
indication lamps contactors, phase indication lamps,
DOL starter for 3 HP pumps relays, control wiring
between day oil storage tank & main panel for high
level trip, low level & high level audio visual alarm.

-
ii) Three (3) No. 63 Amps MCCB for HWG. -
iii) Four (4 ) Nos. 32 Amps MCCB (2 for Steam Boilers
and 2 for 9KW outflow heaters) -
iv) Five (3) Nos. DOL starter for 2.25 KW pump motors. (3
HW Secondary and 2 HW Recirc pumps) -
-
SPARE -
i) One No 63A MCCB -
ii) One no. 32A MCCB -
Control panel as described above. -
Erection and commissioning charges for the above job 98,041.00 Job 1 98,041.00
Note: -
Cabling, wiring earthing shall be included in quoted
prices from main panel to individual equipment. -
-
4 Supplying, installing, testing and commissioning of HSD
storage tank 6 mm thick shell and 8mm thick plains
ends including the following: 415,000.00 Set 2 830,000.00
a) Inlet and Outlet connections -
b) Vent pipe with flame arrester -
c) Dip pipe assembly with calibration chart, complete with
cap, with locking arrangements, with dip, stick
engraving in it. -
d) 500 mm internal dia manhole with cover. -
e) Cleats for anchoring (4 Nos.) -
f) Lifting Lugs -
-
Quantity Amount
S.N Description Rate Unit Remarks
DSR NON DSR DSR NON DSR
g) (The design, fabrication, pressure testing, corrosion
protection, anchoring, earthing etc. will be done strictly
as per IS: 10987-1992 and duly apporved by 'CCOE'
suitable for uderground installation.) -
-
20 KL capacity HSD tank size (Approx.) 2.6 mm dia
and 6 meter long, dimension shall be adjustable as per
site conditions. Including anti- corrosive paint with
primer, bitumin treatment. -
-
5 Supplying, installing, testing and commissioning of
electreical driver rotary gear pumps (Two nos- One
working and one standby) suitable for pumping of HSD
consisting of following: (Pumps shall be suitable for
automatic/manual operation). Self priming gear pump
with weather protection cover for motor (Location:
Inside HSD yard)
45000.00 Nos. 2 90,000.00
a) Horizongally mounted single stage each capable of
delivering 110 LPM at 30 meter head while running at
required RPM, complete with tail pieces for proper
connection to suction and delivery line. -
b) Flame proof motor suitable for 415/-+ 10% V, 3 phase,
50 HZ AC supply and of suitable HP for the above
pumps. -
c) Common bed plate of required strength manufactured
out of MS channel or of cast iron. -
d) Suitable any vibration damping arrangement. -
e) Couping and coupling guard of direct coupling of pump
and motor. -
f) 1 No. pressure gauge on the delivery side of each
pump with isolation cock -
-
6 Providing and fixing MS class 'C' (heavy duty) pipes·
and fittings like Tees, Elbows, Junctions, Unions,
Bends, Plugs, Flanges etc. Clamps, Structural support
as required at site. -
a) 25 mm dia 370.00 RM 20 7,400.00
b) 32 mm dia 440.00 RM 50 22,000.00
c) 40 mm dia 505.00 RM 50 25,250.00
Quantity Amount
S.N Description Rate Unit Remarks
DSR NON DSR DSR NON DSR
d) 50 mm dia 600.00 RM 10 6,000.00
e) 65 mm dia 830.00 RM 10 8,300.00
f) 80 mm dia 1,100.00 RM 10 11,000.00
-
7 Providing installing and testing CI Bucket type strainer
with SS Screen (80 mesh) -
a) 25 mm dia -
b) 32 mm dia -
c) 40 mm dia 5,050.00 Nos. 3 15,150.00
d) 50 mm dia -
e) 65 mm dia -
f) 80 mm dia 10,150.00 Nos. 1 10,150.00
-
8 Providing and fixing forged brass ball valves of the
following sizes: tested to 15 Kg per sq.mm pressure. -
a) 25 mm dia 2,770.00 Nos. 6 16,620.00
b) 32 mm dia 4,150.00 Nos. 4 16,600.00
c) 40 mm dia 6,000.00 Nos. 6 36,000.00
d) 50 mm dia 7,400.00 Nos. 6 44,400.00
e) 65 mm dia 0 -
e) 80 mm dia 13,850.00 Nos. 3 41,550.00
-
9 Providing and fixing GM non return valve of the
following sizes screwed ends. -
a) 25 mm dia -
b) 32 mm dia -
c) 40 mm dia 3,899.00 Nos. 3 11,697.00
d) 50 mm dia - 0 -
-
10 Providing and fixing oil flow meter on the pipes of
following dia complete with bucket tpe strainer, bypass
vallve and full way ball valves on each side with flanged
joints. -
a) 80 mm dia (Unloading) 175,000.00 Set 1 175,000.00
b) 40 mm dia (for DG set) 83,000.00 Set 1 83,000.00
-
Quantity Amount
S.N Description Rate Unit Remarks
DSR NON DSR DSR NON DSR
11 Providing and fixing rubber hose suitalbe for HSD
service at unloading point 3 meter length with coupling
joints. -
a) 80 mm dia 20,250.00 No. 1 20,250.00
-
12 Supply, testing and commissioning of automatic level
controller with low level and high level cut off and alarm
indication. -
a) Day oil tank 27,500.00 Set 1 27,500.00
-
13 FIRE PROTECTION EQUIPMENTS -
a) Providing and fixing of fire bucket (6 nos.) with stand
having capacity of 9 liters conforming to relevant BIS
specifications. 1,250.00 Nos. 6 7,500.00
b) Providing and fixing fire extinguisher mechanical foam
type having capacity of 9 liters (for fighting oil fires) in
accordance with OIS standard- 117 7,500.00 Nos. 6 45,000.00
c) Providing and fixing of 'No smoking and No
Uauthorized Entry sign boards in English and Hindi. 709.00 Nos. 6 4,254.00
-
14 OVERFLOW TANK AND PUMP,: -
Supply, installation, testing and commissioning of 990
ltrs. Capacity overflow storage tanks for HSD
overflowing from day oil tanks installed in DG room.,
The tanks shall be fabricated from 5mm thick MS
Plates.Tank shall include float operated level indicator,
flanged:connections for inlet, outlet,vent,drain etc.Tank
shall be placed at 450 mm below finished floor level
inside plant room. The tank shall be having 550mm dia
manhole for easy access to all equipments/instruments
inside the tank. All equipments/instruments inside
or ,near this tank to be of flame proof construction.

-
a) HSD overflow tank 990 Itrs. (1000 x 1000 x 1000mm
deep) with all accessories as above. 28,500.00 Set 1 28,500.00
b) Rotary or semi rotary manual pump for pumping the
overflow HSD back to day tanks complete with
operating crank/handle etc. 18,500.00 Set 1 18,500.00
NOTE -
Quantity Amount
S.N Description Rate Unit Remarks
DSR NON DSR DSR NON DSR
(Piping, ball valve, NRV,strainer etc. included items
3,5,6 & 4 of this BOQ.) -
-
15 ELECTRICAL WORKS -
STARTER -
DOL starter panel in sheet metal enclosure (three
phase) comprising of TPN MCB, overload relay with
single phasing protection features, ON-OFF and trip
indication lamps, contractors contacts for building
automation system interlocking etc. suitable for 2 No.
motors of motor of 2 HP each.
42,500.00 Set 1 42,500.00
-
16 POWER & CONTROL CABLE END TERMINATION -
Supply and making end termination with brass, single
compression glands for the following PVC insulated
PVC sheathed ,and armoured 1100 volt grad cable
including cost of crimping with crimping tools including,
insullation tapes etc. complete as required. -
-
Suitable for following armoured cables. -
17 4CX1.5 sq.mm copper control cable, 156.00 Nos. 100 15,600.00
-
18 Supply, installation, testing and commissioning of
mushroom head emergency stop flame proof push
buttons with NC contact in sheet metal enclosure
suitable for outdoor use. Push button shall have the
features push to lock and turn to release. 4,608.00 Sets 2 9,216.00
-
19 POWER/CONTROL CABLING AS PER
SPECIFICATIONS -
Supply,installation testing and commissioning of
following sizes of PVC sheated insulated multi-core
sizes of PVC sheathed insulated multi-core power
control armoured , cable of 1.1 KV grade,
copper/aluminium conductor cable in ground including
digging the trench, (upto 1m depth) . laying the cable
with sand and brick covering, back filling etc.or cable
tray including cost of cable tray etc.
-
Quantity Amount
S.N Description Rate Unit Remarks
DSR NON DSR DSR NON DSR
a) 3CX 16 sq.mm Aluminium power cable. 197.00 RM 175 34,475.00

Total Hot Water 3,661,161.00


Balance work for Construction of ESIC Medical College and Hospital at Bihta ,Patna(Bihar)

SOLAR WATER

S.No Description Unit Qty. Rate Amount


DSR NON DSR
Solar Heating System
Supply
1 Supply, Installation & Commissioning of Solar Water Heating System with
all required fittings, clamps, insulation, valves, isolation valves, suitable for
working pressure with flanges, frame, nut bolts & gaskets complete as
required.

a) Commercial System with 24 LC Collector,Heat Exchanger SHX 1500,


60LPM With built in HE Primary Circuit Pumps, Insulation,Electrical Pannel
with Boost
Sets 5.00 2,384,304.00 11,921,520.00

b) Solar collector System unit(with two solar collector on each) -302 with
water capacity of 300 ltr. Sets 76.00 192,081.00 14,598,156.00

2 Civil Works

a) RCC Pillar (300mmx300mm) foundation complete as required. Job L.S. 100,000.00 100,000.00

TOTAL 26,619,676.00
Balance work for Construction of ESIC Medical College and Hospital at Bihta ,Patna(Bihar)

SUMMARY SHEET (BMS)

S.No. DESCRIPTION DSR NON DSR Total

1 BMS 1,407,800.00 19,151,643.00 20,559,443.00

Add 22% on DSR Items 309,716.00 309,716.00

Total BMS 1,717,516.00 19,151,643.00 20,869,159.00


Balance work for Construction of ESIC Medical College and Hospital at Bihta ,Patna(Bihar)

BMS

Quantity Amount
S.N. Description Unit Unit Price Remarks
DSR NON DSR DSR NON DSR

Building Management System (BMS)


1 BMS Workstation with minimum PC
configuration Intel Core 2 Duo, 2 GHz, 250 GB
HDD, 4 GB RAM, 12X DVD drive, 17 " LCD
colour monitor and Colour inkjet printer of A4
size. The system shall have 1000 VA UPS with
30 minutes run time.
No. 107,127.00 1 107127.00

2 BMS Software with following requiment


a Network Management Tool - shall be
compatible with Microsoft Windows XP
Professional and a complete set of integrated
LONWORKS network/ BACnet management
tools for working with LONWORKS/ BACnet
networks.
No. 179,051.00 1 179051.00
b Graphical Programming Software - A set of
tools for the development of the DDC control
logic, point management, global properties such
as alarm, trend and scheduling with 15 user
licenses.
No. 259,927.00 1 259927.00
c System programming software & hardware
provided shall comply with the current release
version of the AX Niagara Framework platform.
No. 391,082.00 1 391082.00
Quantity Amount
S.N. Description Unit Unit Price Remarks
DSR NON DSR DSR NON DSR
3 System Interface Controller (should be capable
of connecting to TCP/IP network) and must
provide hardware features as must provide the
following hardware features as a minimum:
a) One Ethernet Port -10 / 100 Mbps
b) One RS-485 port
c) One LONWORKS Interface Port – 78KB
TP/FT-10
d) Battery Backup
e) Flash memory for long term data backup (If
battery backup or flash memory is not supplied,
the controller must contain a hard disk with at
least 1 gigabyte storage capacity) No. 1,228,660.00 1 1228660.00

f) capable of Calendar
functions,Scheduling, Trending,Alarm
monitoring and routing,Time synchronization,
Integration of LONWORKS controller
data,Integration of BACnet MS/TP and BACnet
IP controllers.

a Digital Electrical Meters Integration No. 54,211.00 1 54211.00


b Chiller Integration No. 54,211.00 1 54211.00
c DG Integration No. 54,211.00 1 54211.00
d FAS Integration No. 54,211.00 1 54211.00
Quantity Amount
S.N. Description Unit Unit Price Remarks
DSR NON DSR DSR NON DSR
4 DDC Controllers with Enclures panels and must
provide hardware features as must provide the
following hardware features as a minimum:

a) shall have a
minimum of 64K of Non-volatile Flash memory
for control applications and 128K non-volatile
flash memory for storage

b) 16 bit A to D resolution

c) Outputs shall
have an adjustable range of 2 seconds to 15
minutes
d) All controllers shall be
LONMARK/ Bacnet Certified
e) Each
controller shall be provided with a XIF file that is
fixed from the manufacture & such XIF file shall
I be
HVACa part of the manufactures normal product

a AHUs Lot 9,558,989.00 1 9558989.00


b Ventilation System Lot 365,779.00 1 365779.00
c Plant Room Lot 477,831.00 1 477831.00

II Electricals

a Main LT & HT panel Lot 116,028.00 1 116028.00


b DG's Lot 98,371.00 1 98371.00
c Internal Lighting Lot 445,863.00 1 445863.00
d External Lighting Lot 72,433.00 1 72433.00

0.00
III Water Supply System Lot 179,751.00 1 179751.00
Quantity Amount
S.N. Description Unit Unit Price Remarks
DSR NON DSR DSR NON DSR

0.00
IV Lifts Lot 117,102.00 1 117102.00
0.00
V Fire Fighting Lot 38,902.00 1 38902.00

5 Field Equipments

a. Oil Level Transmitter No. 27,069.00 1 27069.00


b. Electro magnetic Type Flow Meter No. 382,154.00 1 382154.00
c. Flow Switch Nos. 5,644.00 18 101592.00
d. Immesrsion Type Temp Sensor Nos. 3,591.00 24 86184.00
e. Differntial Pressure Air Flow switch for AHU
runs status and Filter Status 3,055.00
Nos. 434 1325870.00
Differntial Pressure Water Flow Switch for
f. Nos. 11,575.00 45
Pumps
520875.00
g. Duct Temperature Senosr Nos. 4,215.00 434 1829310.00
h. Current Relay Nos. 2,519.00 73 183887.00
i. Level Switch with High/Low Nos. 9,215.00 28 258020.00
j. Pressure Transmitter for water Nos. 15,464.00 2 30928.00
k. LUX Sensor Nos. 21,177.00 3 63531.00
l. Occupancy Sensor Nos. 9,215.00 30 276450.00
m. Ambient Temp Sensor No. 1 34211.00
34,211.00
n. Ambient Humidity Sensor No. 1

o. Voltage Transducer No. 12,786.00 1 12786.00


Quantity Amount
S.N. Description Unit Unit Price Remarks
DSR NON DSR DSR NON DSR

6 Portable operator terminal No. 44,636.00 1 44636.00

7 Cables & conduit


a. Communication Cables CAT 5e/CAT 6 to
interconnect all the controllers, to the
intermediate Bus duct and to the work station.

RM 43.00 2800 120400.00

DSR ITEMS

8 Supplying & drawing following sizes of FR PVC


insulated copper conductor, single core cable in
the existing surface / recessed steel / PVC
conduit as required.(DSR Code No. 1.17,
WGEC)

2 X 1.5 mm2
RM 25.00 23000 575,000.00

9 Supplying & fixing of following sizes of PVC


conduit along with accessories in surface /
recess including cutting the wall & making good
the same in case of recessed conduit as
required. (DSR Code No. 1.21, PVCCON)

a. 20 mm Conduit RM 41.00 2800 114,800.00


b. 25 mm Conduit RM 11000
47.00 517,000.00
Quantity Amount
S.N. Description Unit Unit Price Remarks
DSR NON DSR DSR NON DSR
10 Fabricating and installing following size of
ferforated M.S. cable trays including horizontal
and vertical bends, reducers, tees, cross
members and other accessories as required
and duly suspended from the ceiling with M.S.
suspenders and including painting with powder
coating etc. as required.(DSR Code No. 3.1
CBTR)

11 150 mm width X 50 mm depth X 1.6 mm


thickness(item code 3.1.2) RM 335.00 600 201,000.00

Total For DSR 1,407,800.00 19,151,643.00


Balance work for Construction of ESIC Medical College and Hospital at Bihta ,Patna(Bihar)

SUMMARY SHEET OF DG SETS

SUB As per Deviation-5


DESCRIPTION DSR NON DSR Remarks
HEAD Amount

I DG set & Auxiliary works 131147457 131,147,457.00

II Electrical Panels 20464400 20,464,400.00

III Electrical Works 546018 3840482 4,386,500.00

TOTAL OF DSR ITEMS 546018 155452339 155998357

22% @ OF DSR ITEMS 120123.96 120,123.96

GRAND TOTAL 666141.96 155452339 156,118,480.96


Estimated BOQ of DG Sets & Auxiliaries for Proposed ESIC Medical College & Hospital Campus, Bihta at Patna (Bihar)

DG

Quantity Amunt
S.N. Description Unit Rates Remarks
DSR NON DSR DSR NON DSR

Sub-Head-I : DG set & Auxiliary works


1 D.G. Set
1.1 Design, manufacture, supply, erection, testing & commissioning of
DG Sets of the ratings as given below, having self excited & self
regulated 415 V, 3 Phase, 4-Wire, 50 Hz, 0.8 p.f. Alternator coupled
with multi-cylinder, turbo-charged/ turbo-charged after cooled as
called for, Diesel Engine capable to generate the power not less than
the required BHP to achieve the alternator capacity as given below,
with Heat exchanger cooled radiator, Hospital type silencers and
Electronic governor suitable for Synchronised Operation including
Engine control panel, 24 V batteries of suitable rating, battery-
charger with battery leads and complete with all standard
accessories & protection as required and as specified in the
specifications, including first filling of lube oil providing common
base plate, anti vibration pads, drip trays, foundation bolts, nuts,
bolts, cable termination/adopter box sutiable to terminate upto 7
nos. of 3.5Cx240 sq.mm. XLPE cables/ or Flanges suitable for 2000A /
1600A TPN Al. Bus Duct respectively etc as required for a complete
installation including initial filling
Quantity Amunt
S.N. Description Unit Rates Remarks
DSR NON DSR DSR NON DSR

of fuel and lubricants required during trial run of DG sets on full load
for 12 hours followed by 10% overload for one hour in any 12 hours
duration, as per specifications & drawings complete with RCC/PCC
foundation for DG set as per the structural detail for Dynamic Load
submitted by the Vendor and approve by the Consultant.

Note : The exhaust system should have exhaust bellow just near to
DG sets and before the exhaust silencer to accommidate the
expansion in the exhaust system.
a) 1250 KVA (Without Acoustic Enclosure) Sets 11627233.00 10 116272330
b) 750 KVA (With Acoustic Enclosure) Sets
Quantity Amunt
S.N. Description Unit Rates Remarks
DSR NON DSR DSR NON DSR

Design, manufacture, supply, erection, testing & commissioning of


following rating of DG Sets in Accoustic Enclosure, having self
excited & self regulated 415 V, 3 Phase, 4-Wire, 50 Hz, 0.8 p.f.
Alternator coupled with multi-cylinder, turbo-charged/ turbo-
charged after cooled as called for, Diesel Engine capable to generate
the power not less than the required BHP to achieve the alternator
capacity as given below, with Air-cooled radiator, hospital type
silencers and Electronic governer suitable for Synchronised
Operation including providing of AMF relay, 1600/1000A Circuit
Breaker as called for, & Engine control panel, 24V batteries of
suitable rating, battery-charger with battery leads and complete
with all standard accessories & protection as required and as per
specifications, including first filling of lube oil providing common
base plate, anti vibration pads, drip trays, foundation bolts, nuts,
bolts, cable termination/adopter box sutiable to terminate upto 6/4
nos. of 3.5Cx300 sq.mm. XLPE cables, as required for a complete
installation including initial filling of fuel and lubricants required
during trial run of DG sets on full load for 12 hours followed by 10%
overload for one hour in any 12 hours duration, as per specifications
& drawings complete with RCC/PCC foundation for DG set as per the
structural detail for Dynamic Load submitted by the Vendor and
approve by the Consultant.

Note : The exhaust system should have exhaust bellow just near to
DG sets and before the exhaust silencer to accommidate the
expansion in the exhaust system.
Quantity Amunt
S.N. Description Unit Rates Remarks
DSR NON DSR DSR NON DSR

b) 750 KVA (With Acoustic Enclosure) Sets 0 0

0
3 Exhaust Piping 0
Supply, installation, testing & commissioning of Class ‘C’ M.S. pipe
including bends, flanges, supports etc. as required complete with 75
mm dia fibre glass wool insulation with 26 swg aluminium sheet
cladding.

0
a) 400 mm dia pipe Mtrs 4994.00 350 1747900
b) 300 mm dia pipe Mtrs 4023.00 335 1347705
c) 250 mm dia pipe Mtrs 3457.00 270 933390
d) 200 mm dia pipe Mtrs 0 0
e) 125 mm dia pipe Mtrs 1306.00 110 143660
0
4 Fuel Day Oil Tank ,Vall valves & stainers 0
Supply, fabrication, installation testing & commissioning of M.S. day
oil tanks of following capacity fabricated out of min. 6mm thick
sheet installed on steel frame with all associated accessories, filters,
breathers and fittings including level indicator, complete as required,
including level controller for automatic operation of pumps. The
tank shall be suitably treated with anti corrosive treatment on inside
& outside surface complete with PCC foundation 75mm thick (1:3:6)

a) 990 Litre Sets 55000.00 17 935000

5 Fuel Oil Piping


Supply, installation, testing and commissioning of following 'C-class'
M.S. piping conforming to IS:1239 for fuel piping complete with all
necessary fittings and valves between day oil storage tanks & DG
sets/ priming motor including jointing of pipes, painting of pipes
with two coats of red oxide & two coats of black enamel paint.
Quantity Amunt
S.N. Description Unit Rates Remarks
DSR NON DSR DSR NON DSR

a) 32 mm dia Pipe Mtrs 0.00 0 0


b) 25 mm dia Pipe Mtrs 143.00 500 71500
c) 20 mm dia Pipe Mtrs 0 0
d) 32 mm dia Ball valves Mtrs 0 0
e) 25 mm dia Ball valves Nos. 1851.00 20 37020
f) 20 mm dia Ball valves Nos. 0 0
g) Y-strainer suitable for 32mm dia. pipe. Nos. 0 0
h) Y-strainer suitable for 25mm dia. pipe. Nos. 0 0
i) Y-strainer suitable for 20mm dia. pipe. Nos. 0 0
0
6 Cooling System 0
Supply, installation, testing and commissioning of Induced Draft
Counter flow type FRP cooling tower of following rating of DG &
suitable for heat rejection capacity equivalent to the indicated DG
Set with FRP water basin PVC fillings with integral louvres and drift
eliminators hot water distribution by gravity, complete with
statically and dynamically balanced axial flow gear driven fans with
TEFC induction motor suitable for operation on 415 ± 10% Volts, 3
phase, 50 HZ, A.C. supply, complete with suction screen, make up
and quick fill arrangement, overflow and drain connections, suitable
inspection ladder, access arrangement for cooling tower interior,
and concrete foundation, steel supporting structure, and vibration
mountings etc. complete as per specifications.

0
a) Suitable for 1250 KVA DG set (approx 130 TR) Sets 176000.00 10 1760000
b) Suitable for 625 KVA DG set (approx 80 TR) Sets 128000.00 2 256000
NOTE: Bidder to select suitable capacity cooling tower for the DG
sets offered by them)

7 Supply, installation, testing and commissioning of cooling tower


water pump set of suitable capacity against a head of 25 Mtrs., each
comprising the following and complete as per specifications for the
above system.
Quantity Amunt
S.N. Description Unit Rates Remarks
DSR NON DSR DSR NON DSR

a) Monoblock pump of 1300 LPM for 1250 KVA DG sets (10W+2S)


Nos 108370.00 12 1300440
b) Monoblock pump of 900 LPM for 625 KVA DG sets (2W+1S)
Nos 55000.00 3 165000

8 Supply, installation, testing and commissioning of following sizes of


Nominal Bore (NB) MS 'C'-class pipe suitable for Heat Exchanger to
cooling tower along with necessary clamps, supports, hangers and
fittings including painting as per specs

a) 200 mm dia (NB) Mtr. 1673.00 870 1455510


b) 150 mm dia (NB) Mtr. 988.00 175 172900
c) 125 mm dia (NB) Mtr. 831.00 245 203595
d) 100 mm dia (NB) Mtr. 674.00 93 62682
0
9 Supply, installation, testing and commissioning of following B-class
M.S.ERW pipes of following sizes and material along with necessary
clamps, supports, hangers and fittings such as bends, tees, reducers
etc.but excluding of Valves & strainers and painting as per
specifications.
a) 40 mm dia (from make-up line) Mtrs. 210.00 130 27300
b) 32 mm dia (for Drain Header & Equaliser pipe) Mtrs. 180.00 125 22500
0
10 Supply, installation, testing and commissioning of follwing pipe
accessories like valves, strainers and gauges etc. as per specifications
and conforming to IS:1239.

a) Pot-strainer suitable for 200 mm NB pipe. Nos 20584.00 5 102920


b) Pot-strainer suitable for 150 mm NB pipe. No 13937.00 1 13937
c) Y-strainer suitable for 125 mm NB pipe. Nos 6218.00 15 93270
d) Y-strainer suitable for 100 mm NB pipe. Nos 5003.00 3 15009
e) 200 mm NB Butterfly valves Nos 11421.00 15 171315
f) 150 mm NB Butterfly valves Nos 5175.00 3 15525
g) 125 mm NB Butterfly valves Nos 4774.00 74 353276
h) 100 mm NB Butterfly valves Nos 3759.00 12 45108
i) 40 mm dia Ball valves Nos 2401.00 12 28812
Quantity Amunt
S.N. Description Unit Rates Remarks
DSR NON DSR DSR NON DSR

j) 32 mm dia Ball valves Nos 1951.00 12 23412


k) 125 mm NB non-return valve Nos 5075.00 25 126875
l) 100 mm NB non-return valve Nos 4488.00 5 22440
m) 125 mm NB Balancing (Gate) Valve Nos 12865.00 10 128650
n) 100 mm NB Balancing (Gate) Valve Nos 9302.00 2 18604
o) Gun metal float valve Nos 2400.00 12 28800
p) 125 mm dia. Flexible coupler complete with flanges Sets 6200.00 20 124000
q) 100 mm dia. Flexible coupler complete with flanges Sets 5500.00 4 22000
0
11 a) Supply, installation, testing and commissioning of pressure guage
etc. for above system. Sets 881.00 24 21144
0
b ) Supply, installation, testing and commissioning of temperature
guage etc. for above system.
Sets 747.00 24 17928
0
12 Providing Accoustic insulation in DG Rooms walls & roof by providing
50 mm thickfiber glass blanket of 42 Kg/Cu.M density on angle iron
frame and making a grid of 500mmx500mm. The fiber glass blanket
will be covered with 20 gauge, GI chicken wire mesh and hold to
wall/roof by means of Hilti, Dash fasteners or approved equivalent.
This will be further covered with 26 gauge perforated GI sheet fitted
to angle iron with self tapping screws or other suitable fasteners in
grid of 600x600mm. A thick coat of bitumin primer will be applied to
wall before putting up this accoustic lining.

Sq.M. 1300.00 2200 2860000


0
Total of Sub-Head - I carried to Summary Sheet 131147457

1A PLC based AMF & Synchronisation control Panel-1 for D.G.sets for
L&P
A INCOMER FOR GENERATORS (4 nos.-each 1250 KVA )
Each Incomer for D.G. set shall be provided with the following:
Quantity Amunt
S.N. Description Unit Rates Remarks
DSR NON DSR DSR NON DSR

1 no. 2000A TP EDO ACB (80 KA) with 650A Neutral Isolation Contactor
having programmable trip setting for releases with the following
microprocessor based integral protection:
i) Voltage restraint IDMTL Overcurrent relay,
ii) Unbalance Load protection
iii) Reverse power Protection.
iv) U/V & O/V protection
v) Master trip relay
vi) Restricted Earth fault relay along with 2000/1A PS class CT to be mounted
on neutral of D.G. set
In addition to above relays shall be provided for the following protection:
vii) Anti Pumping device
viii) Trip circuit supervision relay
ix) The ACB shall be complete with 3nos. 2000A/5A, 15VA, 5P10 CTs for
protection .

B Metering & Indication


i) 1 set of R,Y,B phase indicating lamps with 3 nos. 2A SP MCBs.
ii) 1 No. Load Analyser cum digital Multifunction Meter with 3 nos. 2000/5A,
CL-1 CTs, as required.
iii) 1 Set of Breaker ON-OFF-TRIP, Spring charged & Trip circuit healthy
indication Lamps
iv) 1 set of Indication Lamps for NeutraI Isolation Contactor ON & OFF and
Battery charger ON

C INCOMER FOR GENERATORS 2 no.- (625 KVA )

Each Incomer for D.G.set shall be provided with the following:


1 no. 1250A TP EDO ACB (80 KA) with 400A Neutral Isolation Contactor
having programmable trip setting for releases with the following
microprocessor based integral protection:
i) Voltage restraint IDMTL Overcurrent relay,
ii) Unbalance Load protection
iii) Reverse power Protection.
iv) U/V & O/V protection
Quantity Amunt
S.N. Description Unit Rates Remarks
DSR NON DSR DSR NON DSR

v) Master trip relay


vi) Restricted Earth fault relay along with 1250/1A PS class CT to be mounted
on neutral of D.G. set
In addition to above relays shall be provided for the following protection:
vii) Anti Pumping device
viii) Trip circuit supervision relay
ix) The ACB shall be complete with 3nos. 1250A/5A, 15VA, 5P10 CTs for
protection .
D Metering & Indication
i) 1 set of R,Y,B phase indicating lamps with 3 nos. 2A SP MCBs.
ii) 1 No. Load Analyser cum digital Multifunction Meter with 3 nos. 1250/5A,
CL-1 CTs, as required.
iii) 1 Set of Breaker ON-OFF-TRIP, Spring charged & Trip circuit healthy
indication Lamps
iv) 1 set of Indication Lamps for NeutraI Isolation Contactor ON & OFF and
Battery charger ON
E BUS COUPLERs
i) 1no.4000A FP EDO ACB (80KA) with all accessories required.
ii) 1 Set of Breaker ON-OFF-TRIP, Spring charged indication Lamps as
required.
F INTERLOCKING
Incomers from D.G. sets & Bus couplers shall be electrically &
mechanically interlocked.
The Interlocking scheme shall be such that Bus Bar shall be fed individually
by only One D.G. sets under normal operation (No syncronisation) or all the
bus bars shall be fed by any D.G.set in case of Synchronisation mode.

G BUS BARs
i) 2 Sets of 6000A, TPN Aluminum bus bars with colour coded PVC sleeves
H OUTGOINGS
i) 4nos.2500A FP EDO ACB (80KA)
ii) 2 nos. 400A TPN MCCB (80KA)
1.1 Microprocessor based PLC Synchronisation Panel
Design, manufacture, assembly, supply, Installation , Testing &
Commissioning of PLC based Logic Control having follwing features:
Quantity Amunt
S.N. Description Unit Rates Remarks
DSR NON DSR DSR NON DSR

i) AMF operation through Microprocessor including selector switch to Bypass


the PLC for manual operation of D.G. sets
ii) Auto Synchronisation system.
iii) Auto Load sharing among D.G. sets.
The automatic operations to be incorporated in the panel are as follows:-
a The system will directly accept Digital meter & voltmeter signals for
Electrical parameter monitoring and control. Only 1 no. Phase Angle
Transducer shall be provided for all the DG Set Synchronization.
b DG Panel’s logic shall be able to automatically start generators when mains
supply fails by closing the DG switchgear for generator supply. It shall also
transfer the power from emergency to mains supply, when the main healthy
voltage persists for more than two minitues.
c The Transfer of load shall take place only when the generator output reaches
90% of its rated voltage and frequency.
d Automatic load transfer should take place within thirty seconds of mains fail.

e ‘B’ checkup alarm of each D.G. set after 300 hours of running for proper
maintenance.
f All parameters of individual D.G. set shall be monitored & necessary
commands shall adjust the parameters of that D.G. Set feeding the bus bar
of Main Panel.
g Auto synchronizing system shall verify the phase angle of D.G. sets and also
compensate for ACB closing time by initiating closing of the breaker ahead
of the actual predictable synchronism thereby ensuring a phase difference of
zero degree.
h System shall also monitor the slip frequency and the beat voltage of the
machine or system.
i Neutral Isolation switch of Generator running in the system shall not trip
until the Neutral Isolation switch of other Generator is closed in the event of
shutting off of first Generator and starting the other.
j It shall be possible to alter sequence of D.G.set through manual selectors or
through man-machine interface.
k Active power shall be made equal on all the sets automatically with the help
of ACTIVE LOAD BALANCING system through Governor Control.
l Reactive power shall be balanced automatically with the help of quadrature
droop kit already fitted on the machine.
Quantity Amunt
S.N. Description Unit Rates Remarks
DSR NON DSR DSR NON DSR

m However if qudrature droop system is not functioning accurately


‘REACTIVE LOAD BALANCING’ system shall control the motorised
potentiometer to achieve KVAR regulation within preset band.
n In the event of set failing to synchronize, alarm from Annunciator would
invite attention of operator for manual intervention.
o It shall be possible to alter crucial setting / time delays through MAN
MACHINE INTERFACE. (through BMS Software)
p Relays shall have compatibility for future interface with BMS Software
graphic displays / report generation.
q System shall have TOTAL MANUAL synchronization facility.
r The Microprocessor (PLC) shall start DG sets in sequence as per the
readings of KW/KVA meter provided on transformer & D.G. set incomers at
the instant of power failure and the sequence of operation will be as
specified.
s The PLC shall start the the two bigger set to feeding the two bus and it will
share the load of the these two bus if the total demand load on the two
segement on each side of Bus-coupler is below 90% of the capacity of the
any one running D.G.set,by opening Incomer of the second set before
closing the Bus-coupler.

t The PLC system shall able to monitor the Load on the each Bus-section
individually.
u If the Total/ Individual demand Load on Bus-section increases from the 90%
capacity of the running D.G. sets then the PLC will start the other D.G. sets
one by one as per the Demand load requirement, and after sysnchronising
with the system bus it will transfer the proportional load on the set by
closing the Incomer of that set, and accordingly switch OFF the smaller D.G.
sets as per the Demand Load on that Bus.

v Similiary during the reduction of Demand load the Relay will switch OFF or
Switch ON the relevant D.G.sets as per preset demand load.
w On restoration of grid supply, Incomer Switches from D.G. sets and Bus
coupler shall be switched ‘OFF’ in preset sequence and then switch ON the
Incomer ACB of Transformer. DG Set shall continue to run for three
minutes at reduced speed after DG Switch has been switched ‘OFF’ after
that the D.G. set will be Switched Off.

1.2 The PLC panel shall be provided with all the necessary protection
switches, relays, potential free contacts , Anuunciation windows, etc as
required to achieve the above logic and complete with the following:
Quantity Amunt
S.N. Description Unit Rates Remarks
DSR NON DSR DSR NON DSR

a D.G. control Panel with Mannual synchronization for Each D.G. set
with the following:
i. 1 No. Digital Multifunction Meter
ii. 1 No. D.C. Voltmeter for Battery
iii. 1 No. D.C. Ammeter for Battery
iv. Switch for Speed Raise & Low
v. Switch for Voltage Raise & Low
vi. Push Button for D.G. Start
vii. Push Button for D.G. Stop
viii. Emergency Stop Push Button
ix. 16 windows Annunciator with hooter.
x. Field Failure Relay
xi. Out of Step protection Relay
xii. AMF Relay
xiii. 3 nos. Potentiometers
b AUTO SYNCHRONIZING
1 No. PLC Comprising of:
i. Main Processing unit
ii. Power Monitor 3000.
iii. Digital input Modules
iv. Digital output Modules
v. EPROM for Main Processor
vi. Panel view 550
vii. 1 No. Double Voltmeter
viii. 1 No. Double Frequency Meter
ix. 1 No. Synchroscope
x. 1 No. Synchronizing Switch
xi. DG Selector Switch (6 way Selector switch )
xii. 1 Set Dark Lamps
xiii. Manual Overriding facility from Auto Synchronizing.
xiv. Auto / Manual / Test Switch
Quantity Amunt
S.N. Description Unit Rates Remarks
DSR NON DSR DSR NON DSR

xv.
2 Nos. 16 windows Annunciator with hooter for status indicator for breakers.
xvi. Mimic with Led Indicator for Power supply Status
xvii. The PLC shall be complete with all necesaary switches, fuses etc. as given
below, to fulfill the desired application as required.
xviii. Aux. Relays
xix. Indicating Lights & Push Buttons
xx. Control fuses/ MCBs
c Load Analyser (Power monitor 3000)shall have following features: -
i. Voltage, current, frequency, P.F., KVA, KVAR, KW, KVAH, KVARH,
KWH measurement for single and three phase source.
ii. 50 ms update rates for metering results
iii. Port for PC compatibility
iv. Output Control via control relays or PLC
v. Input monitoring via status inputs
vi. Time stamped data logging of system measurements and events
vii. Total Harmonic Distortion
viii. Configurable trend log, upto 45,000 records
ix. Firmware upgrades without removing module
d Annunciation Window for each Generator as follows:
i. Electrical Fault
ii. Excitation Failure
iii. Reverse Power
iv. Emergency Shutdown
v. Over Speed
vi. Low Lube Oil Pressure
vii. High Water Temperature
viii. Engine Overheating
ix. Cooling Water Flow Failure
x. Bearing Temperature High
xi. Winding Temperature High
xii. Low Fuel Level
Quantity Amunt
S.N. Description Unit Rates Remarks
DSR NON DSR DSR NON DSR

xiii. Spare- 4nos.


e Annunciation Window for Auto Synchronising (2 nos.)
i. DG - 1 / 4 Fails to Start
ii. DG - 1 / 4 Fails to Synchronize
iii. DG - 1 / 4 Neutral Discrepancy
iv. DG - 1 / 4 ACB Fails to close
v. DG - 2 / 5 Fails to Start
vi. DG - 2 / 5 Fails to Synchronize
vii. DG - 2 / 5 Neutral Discrepancy
viii. DG - 2 / 5 ACB Fails to close
ix. DG - 3 / 6 Fails to start
x. DG - 3 / 6 Fails to synchronize
xi. DG - 3 / 6 Neutral discrepancy
xii. DG - 3 / 6 ACB Fails to close
xiii. Bus coupler - fails to close
xiv. Spare-3nos.
f For Power Supply Status Indicator (Mimic)
i. DG - 1 Supply available
ii. DG - 1 Neutral '‘ON/ OFF'
iii. DG - 2 Supply available
iv. DG - 2 Neutral '‘ON/ OFF'’
v. DG - 3 Supply available
vi. DG - 3 Neutral ‘'ON/ OFF'’
vii. DG - 4 Supply available
viii. DG - 4 Neutral ‘'ON/ OFF'’
ix. DG - 5 Supply available
x. DG - 5 Neutral ‘'ON/ OFF'’
xi. DG - 6 Supply available
xii. DG - 6 Neutral ‘'ON/ OFF'’
xiii. Bus coupler - ‘'ON/ OFF'’
xiv. Mains Supply available
Quantity Amunt
S.N. Description Unit Rates Remarks
DSR NON DSR DSR NON DSR

Note:-
1
All the above mentioned components like I/O ports, relay modules,
synchronisation relay, annunciation window shall be housed in the
Synchronisatio Panel.
2 The PLC control panel shall be complete in alll respect to accompolished the
desired operation and the vendor shall supply all the necessary switches
fuses, relays, CTs, Digital/ Analogue Input/Output racks for interface, 2
KVA UPS backup with SMF battery
3 Contractor shall provide the detail of NO & NC contacts required in the
D.G.sets' control panel for AMF & Auto-synchronisation proccess which
will be provided alongwith the motorised potentio-meter with the D.G.set
within the accoustic enclosure.
Supply for Microproccesor based Synchronisation Panel-1 as described
above Set 7530000.00 1 7530000
Receiving, Installation, testing & Commissioning for the above Panel-1.
Set 20000.00 1 20000

2.A PLC based AMF & Synchronisation control Panel-2 for D.G.sets for
HVAC Plant
A INCOMER FOR GENERATORS (6 nos.-each 1250 KVA )
Each Incomer for D.G. set shall be provided with the following:
1 no. 2000A TP EDO ACB (80 KA)with 650A Neutral Isolation Contactor
having programmable trip setting for releases with the following
microprocessor based integral protection:

i) Voltage restraint IDMTL Overcurrent relay,


ii) Unbalance Load protection
iii) Reverse power Protection.
iv) U/V & O/V protection
v) Master trip relay
vi) Restricted Earth fault relay along with 2000/1A PS class CT to be mounted
on neutral of D.G. set
In addition to above relays shall be provided for the following protection:
vii) Anti Pumping device
viii) Trip circuit supervision relay
Quantity Amunt
S.N. Description Unit Rates Remarks
DSR NON DSR DSR NON DSR

ix) The ACB shall be complete with 3nos. 2000A/5A, 15VA, 5P10 CTs for
protection .
B METERING & INDICATION
i) 1 set of R,Y,B phase indicating lamps with 3 nos. 2A SP MCBs.
ii) 1 No. Load Analyser cum digital Multifunction Meter with 3 nos. 2000/5A,
CL-1 CTs, as required.
iii) 1 Set of Breaker ON-OFF-TRIP, Spring charged & Trip circuit healthy
indication Lamps
iv) 1 set of Indication Lamps for NeutraI Isolation Contactor ON & OFF and
Battery charger ON
C BUS COUPLER
i) 1no.4000A FP EDO ACB (80 KA) with all accessories required.
ii) 1 Set of Breaker ON-OFF-TRIP, Spring charged indication Lamps as
required.
D INTERLOCKING
Incomers from D.G. sets & Bus couplers shall be electrically &
mechanically interlocked.

The Interlocking scheme shall be such that Bus Bar shall be fed individually
by only One D.G. sets under normal operation (No syncronisation) or both
the bus bars shall be fed by any D.G.set in case of Synchronisation mode.
E BUS BARS
2 Sets of 6000A, TPN Aluminum bus bars with colour coded PVC sleeves
F OUTGOINGS
i) 4 nos.2500A FP EDO ACB (80KA)
ii) 2 nos. 400A TPN MCCB (80KA)
2.1 Microprocessor based PLC Synchronisation Panel
Design, manufacture, assembly, supply, Installation , Testing &
Commissioning of PLC based Logic Control having follwing features:
i) AMF operation through Microprocessor including selector switch to Bypass
the PLC for manual operation of D.G. sets
ii) Auto Synchronisation system.
iii) Auto Load sharing among D.G. sets.
The automatic operations to be incorporated in the panel are as follows:-
Quantity Amunt
S.N. Description Unit Rates Remarks
DSR NON DSR DSR NON DSR

a The system will directly accept Digital meter & voltmeter signals for
Electrical parameter monitoring and control. Only 1 no. Phase Angle
Transducer shall be provided for all the DG Set Synchronization.
b DG Panel’s logic shall be able to automatically start generators when mains
supply fails by closing the DG switchgear for generator supply. It shall also
transfer the power from emergency to mains supply, when the main healthy
voltage persists for more than two minitues.
c The Transfer of load shall take place only when the generator output reaches
90% of its rated voltage and frequency.
d Automatic load transfer should take place within thirty seconds of mains fail.

e ‘B’ checkup alarm of each D.G. set after 300 hours of running for proper
maintenance.
f All parameters of individual D.G. set shall be monitored & necessary
commands shall adjust the parameters of that D.G. Set feeding the bus bar
of Main Panel.
g Auto synchronizing system shall verify the phase angle of D.G. sets and also
compensate for ACB closing time by initiating closing of the breaker ahead
of the actual predictable synchronism thereby ensuring a phase difference of
zero degree.
h System shall also monitor the slip frequency and the beat voltage of the
machine or system.
i Neutral Isolation switch of Generator running in the system shall not trip
until the Neutral Isolation switch of other Generator is closed in the event of
shutting off of first Generator and starting the other.
j It shall be possible to alter sequence of D.G.set through manual selectors or
through man-machine interface.
k Active power shall be made equal on all the sets automatically with the help
of ACTIVE LOAD BALANCING system through Governor Control.
l Reactive power shall be balanced automatically with the help of quadrature
droop kit already fitted on the machine.
m However if qudrature droop system is not functioning accurately
‘REACTIVE LOAD BALANCING’ system shall control the motorised
potentiometer to achieve KVAR regulation within preset band.
n In the event of set failing to synchronize, alarm from Annunciator would
invite attention of operator for manual intervention.
Quantity Amunt
S.N. Description Unit Rates Remarks
DSR NON DSR DSR NON DSR

o It shall be possible to alter crucial setting / time delays through MAN


MACHINE INTERFACE. (through BMS Software)
p Relays shall have compatibility for future interface with BMS Software
graphic displays / report generation.
q System shall have TOTAL MANUAL synchronization facility.
r The Microprocessor (PLC) shall start DG sets in sequence as per the
readings of KW/KVA meter provided on transformer & D.G. set incomers at
the instant of power failure and the sequence of operation will be as
specified.
s The PLC shall start the the two bigger set to feeding the two bus and it will
share the load of the these two bus if the total demand load on the two
segement on each side of Bus-coupler is below 90% of the capacity of the
any one running D.G.set,by opening Incomer of the second set before
closing the Bus-coupler.

t The PLC system shall able to monitor the Load on the both the Bus-section
individually.
u If the Total/ Individual demand Load on Bus-section increases from the 90%
capacity of the running D.G. sets then the PLC will start the other D.G. sets
one by one as per the Demand load requirement, and after sysnchronising
with the system bus it will transfer the proportional load on the set by
closing the Incomer of that set, and accordingly switch OFF the smaller D.G.
sets as per the Demand Load on that Bus.

v Similiary during the reduction of Demand load the PLC will switch OFF or
Switch ON the relevant D.G.sets as per preset demand load.
w On restoration of grid supply, Incomer Switches from D.G. sets and Bus
coupler shall be switched ‘OFF’ in preset sequence and then switch ON the
Incomer ACB of Transformer. DG Set shall continue to run for three
minutes at reduced speed after DG Switch has been switched ‘OFF’ after
that the D.G. set will be Switched Off.

2.2 The PLC panel shall be provided with all the necessary protection switches,
relays, potential free contacts , Anuunciation windows, etc as required to
achieve the above logic and complete with the following:
a D.G. control Panel with Mannual synchronization for Each D.G. set with the
following:
i. 1 No. Digital Multifunction Meter
ii. 1 No. D.C. Voltmeter for Battery
iii. 1 No. D.C. Ammeter for Battery
Quantity Amunt
S.N. Description Unit Rates Remarks
DSR NON DSR DSR NON DSR

iv. Switch for Speed Raise & Low


v. Switch for Voltage Raise & Low
vi. Push Button for D.G. Start
vii. Push Button for D.G. Stop
viii. Emergency Stop Push Button
ix. 16 windows Annunciator with hooter.
x. Field Failure Relay
xi. Out of Step protection Relay
xii. AMF Relay
xiii. 3 nos. Potentiometers
b AUTO SYNCHRONIZING
1 No. PLC Comprising of:
i. Main Processing unit
ii. Power Monitor 3000.
iii. Digital input Modules
iv. Digital output Modules
v. EPROM for Main Processor
vi. Panel view 550
vii. 1 No. Double Voltmeter
viii. 1 No. Double Frequency Meter
ix. 1 No. Synchroscope
x. 1 No. Synchronizing Switch
xi. DG Selector Switch (4 way Selector switch )
xii. 1 Set Dark Lamps
xiii. Manual Overriding facility from Auto Synchronizing.
xiv. Auto / Manual / Test Switch
xv.
2 Nos. 16 windows Annunciator with hooter for status indicator for breakers.
xvi. Mimic with Led Indicator for Power supply Status
xvii. The PLC shall be complete with all necesaary switches, fuses etc. as given
below, to fulfill the desired application as required.
xviii. Aux. Relays
Quantity Amunt
S.N. Description Unit Rates Remarks
DSR NON DSR DSR NON DSR

xix. Indicating Lights & Push Buttons


xx. Control fuses/ MCBs
c Load Analyser (Power monitor 3000)shall have following features: -
i. Voltage, current, frequency, P.F., KVA, KVAR, KW, KVAH, KVARH,
KWH measurement for single and three phase source.
ii. 50 ms update rates for metering results
iii. Port for PC compatibility
iv. Output Control via control relays or PLC
v. Input monitoring via status inputs
vi. Time stamped data logging of system measurements and events
vii. Total Harmonic Distortion
viii. Configurable trend log, upto 45,000 records
ix. Firmware upgrades without removing module
d Annunciation Window for each Generator as follows:
i. Electrical Fault
ii. Excitation Failure
iii. Reverse Power
iv. Emergency Shutdown
v. Over Speed
vi. Low Lube Oil Pressure
vii. High Water Temperature
viii. Engine Overheating
ix. Cooling Water Flow Failure
x. Bearing Temperature High
xi. Winding Temperature High
xii. Low Fuel Level
xiii. Spare- 4nos.
e Annunciation Window for Auto Synchronising
i. DG - 1 / 4 Fails to Start
ii. DG - 1 / 4 Fails to Synchronize
iii. DG - 1 / 4 Neutral Discrepancy
iv. DG - 1 / 4 ACB Fails to close
v. DG - 2 / 5 Fails to Start
Quantity Amunt
S.N. Description Unit Rates Remarks
DSR NON DSR DSR NON DSR

vi. DG - 2 / 5 Fails to Synchronize


vii. DG - 2 / 5 Neutral Discrepancy
viii. DG - 2 / 5 ACB Fails to close
ix. DG - 3 / 6 Fails to start
x. DG - 3 / 6 Fails to synchronize
xi. DG - 3 / 6 Neutral discrepancy
xii. DG - 3 / 6 ACB Fails to close
xiii. Bus coupler - fails to close
xiv. Spare-3nos.
f For Power Supply Status Indicator (Mimic)
i. DG - 1 Supply available
ii. DG - 1 Neutral '‘ON/ OFF'
iii. DG - 2 Supply available
iv. DG - 2 Neutral '‘ON/ OFF'’
v. DG - 3 Supply available
vi. DG - 3 Neutral ‘'ON/ OFF'’
vii. DG - 4 Supply available
viii. DG - 4 Neutral ‘'ON/ OFF'’
ix. DG - 5 Supply available
x. DG - 5 Neutral ‘'ON/ OFF'’
xi. DG - 6 Supply available
xii. DG - 6 Neutral ‘'ON/ OFF'’
xiii. Bus coupler - ‘'ON/ OFF'’
xiv. Mains Supply available
Note:-
1 All the above mentioned components like I/O ports, relay modules,
synchronisation relay, annunciation window shall be housed in the
Synchronisatio Panel.
2
The PLC control panel shall be complete in alll respect to accompolished the
desired operation and the vendor shall supply all the necessary switches
fuses, relays, CTs, Digital/ Analogue Input/Output racks for interface, 1
KVA UPS backup with SMF battery
Quantity Amunt
S.N. Description Unit Rates Remarks
DSR NON DSR DSR NON DSR

3
Contractor shall provide the detail of NO & NC contacts required in the
D.G.sets' control panel for AMF & Auto-synchronisation proccess which
will be provided alongwith the motorised potentio-meter with the D.G.set
within the accoustic enclosure.
Supply for Microproccesor based Synchronisation Panel-2 as described
above Set 7550000.00 0

Receiving, Installation, testing & Commissioning for the above Panel-2. Set 20000.00 0

3 DG Auxillary Panel - 1 & 2 (Typical for 3 & 4)


A INCOMER
2Nos. 400A TPN MCCB (50 KA)
B METERING & INDICATION
i) 2 sets of R,Y,B phase indicating lamps
ii) 2 No. (0-500V) Voltmeter with Built-in VSS each with 3 nos. 2A SP MCB
iii) 2 No. (0-400A) Ammeter each with ASS with 3 nos. 400/5A CT's
C BUS-BAR
2 Set of 400A TPN Aluminium Bus Bar with colour coded PVC Sleeves
D BUS COUPLER:
i) 1 No. 400A FP MCCB (35KA)
E INTERLOCKING
Incomers for L.T. Panel & Bus coupler shall be electrically & mechanically
interlocked.
F OUTGOINGS
i) 4 Nos. 80A TP MCCB (45 KA)
ii) 10 Nos. 63A TP MCCB (45 KA)
iii) 12 Nos. 40A TP MCCB (45 KA)
iv) 10 Nos. 10A / 32A TP MCB (10 KA)
v) 6 Nos. 10A / 32A DP MCB (10 KA)
vi) 3 Nos. S/D starter with self illuminated Push button for ON & OFF and
suitable rating of contactor and O/L relays, suitable for 30 HP Motor.
vii) 3 Nos. S/D starter with self illuminated Push button for ON & OFF and
suitable rating of contactor and O/L relays, suitable for 20 HP Motor.
viii) 6 Nos. S/D starter with self illuminated Push button for ON & OFF and
suitable rating of contactor and O/L relays, suitable for 15 HP Motor.
Quantity Amunt
S.N. Description Unit Rates Remarks
DSR NON DSR DSR NON DSR

ix) 2 Nos. S/D starter with self illuminated Push button for ON & OFF and
suitable rating of contactor and O/L relays, suitable for 10 HP Motor.
x) 6 No. DOL starter with self illuminated Push button for ON & OFF and
suitable rating of contactor and O/L relays, suitable for 7.5 HP Motor.
xi) 2 No. DOL starter with self illuminated Push button for ON & OFF and
suitable rating of contactor and O/L relays, suitable for 5 HP Motor.
xii) 2 Nos.space for S/D starter with self illuminated Push button for ON &
OFF.
xiii) Connector Block/Strip of suitable no.of pairs complete with wiring upto all
Starters, for interlocking the pumps & Cooling tower's fan with individual
D.G.set.
G INTERLOCKING
The starters shall automatically start the CT Pumps and fans with their
respective DG Sets
Supply of D.G Auxillary Panel- 1 & 2 as described above. Set 0
Receiving, fixing, testing & commissioning of D.G Auxillary Panel-1 &
2 as described above Set 0

5 SANDWICH TYPE BUS TRUNKING 0


Design, supply, installation, testing and commisioning of following ratings
of powder coated sheet steel enclosed (IP 42) 415V, 50 Hz., Three phase &
neutral Aluminium conductor Bus Duct suitable for 25 MVA fault rating,
including bends/elbows, transposition piece, expansion joint, Terminal End
connector & all flexible connections as per specifications with all
accessories, supports, hardwares and termination of bus duct to switchgear.

0
5.1 2000A TPN Aluminium Bus Duct (35 MVA fault rating) in weather proof
Enclosure RM 34200.00 290 9918000
5.2 1250A TPN Aluminium Bus Duct (35 MVA fault rating) in weather proof
Enclosure RM 27800.00 78 2168400
5.3 Copper flexible End Termination for 2000A TPN No 37000.00 20 740000
5.4 Copper flexible End Termination for 1250A TPN No 22000.00 4 88000

Sub-Head-II 20464400

Sub-Head-III : L.T. Cables & Bus Trunking


Quantity Amunt
S.N. Description Unit Rates Remarks
DSR NON DSR DSR NON DSR

1 Supplying of following sizes of XLPE/ PVC insulated Aluminum/ Copper


conductor and Armoured, overall PVC sheathed 1.1 KV grade cables
conforming to relevant IS code and technical specifications.
1.1 XLPE insulated Al. Ar.Cable
a 3.5C x 300 sq.mm. RM 2046.00 800 1636800
b 3.5C x 240 sq.mm. RM 0 0
c 3C x 25 sq. mm. RM 249.00 480 119520
d 3C x 16 sq. mm. RM 211.00 640 135040
e 3C x 10 sq. mm. RM 190.00 1040 197600
f 3C x 6 sq. mm. RM 174.00 900 156600
g 3C x 4 sq. mm. RM 135.00 60 8100
0
1.2 Supplying of following sizes of XLPE/ PVC insulated Copper control
conductor and Armoured/Unarmoured cable with lugs conforming to 0
relevant IS code and technical specifications.
a 4C x 4 Sq.mm. RM 339.00 568 192552
b 3C x 2.5 Sq.mm. RM 206.00 702 144612
c 7C x 2.5 Sq.mm. RM 389.00 398 154822
d 12C x 2.5 Sq.mm. RM 588.00 500 294000
e 14C x 2.5 Sq.mm. RM 671.00 606 406626
f 19C x 2.5 Sq.mm. RM 883.00 400 353200
0
2 Supply and making End termination with brass Single compression gland
including providing and crimping of copper/Al. solderless lugs/ferrules for
XLPE/PVC insulated armoured power aluminum/copper conductor cables 0
1.1 KV grade of following sizes:
2.1 Single Compression Gland for Cu.Ar.Cable 0
a 2C/ 4C x 2.5/ 4.0 sq.mm. Sets 103.00 56 5768
b 7C x 2.5 sq.mm. Sets 143.00 24 3432
c 12C / 14C x 2.5 sq.mm. Sets 216.00 64 13824
d 19C x 2.5 Sq.mm. Sets 290.00 48 13920
0
2.2 Single Compression Gland for Al. Ar.Cable 0
3C / 4C x 6 sq.mm. Sets 107.00 38 4066

Total of Sub Head III Non DSR Items


DSR Items
Quantity Amunt
S.N. Description Unit Rates Remarks
DSR NON DSR DSR NON DSR

1 Laying and fixing of one number PVC insulated and PVC sheathed/XLPE
aluminum conductor cable of 1.1 KV grade of size not exceeding 25 sqmm
on surface as required. (DSR 2007 1.11 MVCBSUR25) RM 31.00 5090 157790

2 Laying and fixing of one number PVC insulated and PVC sheathed/XLPE
aluminum conductor cable of 1.1 KV grade of size exceeding 120 sqmm but
not eceeding 400sqmm on surface as required. (DSR 2007 1.13
MVCBSUR400)
RM 61 800 48800

3 Supply and making End termination with brass compression gland and
aluminum lugs for following sizes of PVC insulated and PVC sheathed/
XLPE aluminum conductor cable of 1.1KV grade as required.
a 3.5C x 300 sq.mm. (DSR2007 4.1.30 MVET) Sets 508.00 64 32512
b 3.5C x 240 sq.mm. (DSR2007 4.1.29 MVET) Sets
c 3C x 25 sq.mm. (DSR2007 4.1.9 MVET) Sets 128.00 24 3072
d 3C x 16 sq. mm. (DSR2007 4.1.8 MVET) Sets 120.00 32 3840
e 3C x10 sq. mm. (DSR2007 4.1.7 MVET) Sets 102.00 52 5304

4 Fabricating and installing following size of perforated MS cable trays


including horizontal and vertical bends, reducers, tees cross members and
others accessories as required and duly suspended from the ceiling wih MS
suspended and including painting with powder coating etc. as required
a 900 mm width X 75mm depth X 2mm thickness (DSR2007 3.1.16 CBTR) Mtrs. 1310.00 40 52400
b
600 mm width X 62.5 mm depth X 2mm thickness (DSR2007 3.1.11 CBTR) Mtrs. 1010.00 220
222200
c 150 mm width X 50mm depth X 1.6mm thickness (DSR2007 3.1.2 CBTR) Mtrs. 335.00 60 20100

Total of Sub-Head - III carried to summary sheet (DSR ITEM) 546018 3840482