Nothing Special   »   [go: up one dir, main page]

iCP-640 Capacitor Bank Protection Relay

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

iCP-640 Capacitor Bank Protection Relay

Ample Sensitivity to Detect Unit Failures in Larger Banks

Your Solution for Shunt


Capacitor or Filter Bank
Protection and Control
iCP-640
T h e i C P - 6 4 0 r e l a y m o n i t o r s c a p a c i t or p e r f o r m a n c e
by checking the voltage differential quantity of
single or double wye, fuseless or externally fused
g r o u n d e d b a n k s . To o p t i m i z e p r o t e c t i o n m a r g i n s ,
this relay has the intelligence to track self-canceling
relay

Externally
Fused Bank
Application
Example
failures found in double-wye banks or single-wye
banks with mid-point taps.

Exclus ive Cooper features and fu n c t i o n s , i n c l u d i n g t h e I d e a Wo r k b e n c h T M , V i r t u a l Te st S e t T M , a n d


Relay Replay T M software functiona l i t y, p r o v i d e t h e u n p r e c e d e n t e d a b i l i t y t o o b s e r v e t h e r e l a y ’s p r o t e c t i o n
protection

and co ntrol functions while offer i n g f l e x i b i l i t y f o r c u s t o m a p p l i c a t i o n s .

Technically Advanced Capacitor Relay


n With advanced features for detection and control, the iCP-640 relay helps improve reliability and reduce outage time. It detects
capacitor unit failure when the compensated voltage differential or impedance change quantity increases beyond a threshold. It
then reduces outage time by pinpointing the smallest affected area within the bank. Because it is easily configured to permit
the nulling of inherent bank unbalance, the relay provides maximum sensitivity for detecting internal problems.

Complete Capacitor Bank Protection


n The iCP-640 relay is used for protection and control of shunt capacitor or filter banks. It provides backup overcurrent and
bank

under- and overvoltage protection, voltage control, and comprehensive metering up to the 15th harmonic. Cooper
offers protective relays for a wide range of capacitor bank applications including:
voltage differential, neutral unbalance, impedance, and negative sequence.

Get the Right Solution to Improve Reliability


capacitor

n The Edison® Idea™ family of relays offers inherent communications options that
improve reliability. Cooper can provide protective relays for a wide range of
applications including distribution feeders, transformers, transmission lines,
and capacitor bank protection. Our experienced relay engineers are available
to provide application support when you need it.

For more information, visit our


Web site at www.cooperpower.com,
iCP-640

contact your Cooper Power Systems


sales engineer, or call 877-CPS-INFO. 1045 Hickory Street
Pewaukee, WI 53072 USA
Edison is a registered trademark of Cooper Power Systems, Inc., or its affiliates.
®
www.cooperpower.com
Idea™, Idea WorkbenchTM, Virtual Test SetTM and Relay ReplayTM
are trademarks of Cooper Power Systems, Inc., or its affiliates.

©2007 Cooper Power Systems, Inc., or its affiliates. Bulletin B165-07006 • March 2007 • New Issue

You might also like