Nothing Special   »   [go: up one dir, main page]

iCP-630 Capacitor Bank Protection Relay

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

iCP-630 Capacitor Bank Protection Relay

Lowers Installation Costs and Reduces Outage Time

Your Solution for Ungrounded


Shunt Capacitor or Filter Bank
Protection and Control
T h e i C P - 6 3 0 r e l a y m o n i t o r s c a p a c i t o r p e r f or ma nc e
b y c o m p a r i n g r e a l - t i m e m e a s u r e m e n t s o f c o mp en sa te d
n e g a t i v e s e q u e n c e c u r r e n t t o u s e r s e t - p o i n t s. U si ng
t h i s r e l a y s a v e s i n s t a l l a t i o n a n d m a i n t e n a n c e co st s
b e c a u s e i t p r o v i d e s s e n s i t i v e u n b a l a n c e p r o te ct io n
RELAY

u s i n g t h e e x i s t i n g b u s V Ts a n d b a n k C Ts , a nd d oe s
n o t r e q u i r e a n e u t r a l - t o - g r o u n d v o l t a g e t r a nd uc er.

Exclusive Cooper features and functions , i n c l u d i n g t h e I d e a Wo r k b e n c h T M , V i r t u a l Te s t S e t T M , a nd


Relay Replay T M software functionality, pr o v i d e t h e u n p r e c e d e n t e d a b i l i t y t o o b s e r v e t h e r e l a y ’s
PROTECTION

protection and control functions while o f f e r i n g f l e x i b i l i t y f o r c u s t o m a p p l i c a t i o n s .

Technically Advanced Capacitor Relay


■ The iCP-630 relay offers the features you need to increase system reliability and lower costs. First, the relay protects the
system by detecting capacitor bank unbalance when the compensated negative sequence increases beyond a threshold.
Then the iCP-630 relay reduces outage time by pinpointing the phase of a capacitor can failure. Eliminating the neutral
ground voltage transducer lowers installation and maintenance costs. Because it is easily configured to permit the
nulling of inherent bank unbalance, the relay provides maximum sensitivity for detecting internal problems.

Complete Capacitor Bank Protection


Use the iCP-630 relay for protection and control of ungrounded shunt capacitor or filter banks. It provides backup overcurrent
BANK

and under- and overvoltage protection, voltage control, and comprehensive metering up to the 15th harmonic. Cooper offers
protective relays for a wide range of capacitor bank applications including: voltage
differential, neutral unbalance, impedance, and negative sequence.

Get the Right Solution to Improve Reliability


CAPACITOR

■ The Edison® Idea™ family of relays offers inherent communications options that improve
reliability. Cooper can provide protective relays for a wide range of applications including
distribution feeders, transformers, transmission lines, and capacitor bank protection. Our
experienced relay engineers are available to provide application support when you need it.

For more information, visit our


Web site at www.cooperpower.com,
iCP-630

contact your Cooper Power Systems


sales engineer, or call 877-CPS-INFO. 1045 Hickory Street
Edison® is a registered trademark of Cooper Power Systems, Inc., or its affiliates.
Pewaukee, WI 53072 USA
Idea™, Idea WorkbenchTM, Virtual Test SetTM and Relay ReplayTM
www.cooperpower.com
are trademarks of Cooper Power Systems, Inc., or its affiliates.

©2007 Cooper Power Systems, Inc., or its affiliates. Bulletin B165-06052 • March 2007 • New Issue