Ace G300LH
Ace G300LH
Ace G300LH
by Nemko
Starting current A
Model PG225X2C-4FT
Rotary
Type
TOSHIBA
Brand
Input W 1290/1335
Compressor
Rated current(RLA) A 6.1
Capacitor uF 35
Refrigerant oil ml 480
RPG20D
Model
49.2
Input W
Indoor fan motor
1.5
Capacitor uF
Speed(hi/mi/lo) r/min 1060/900/800
580/550/520
Indoor air flow (Hi/Mi/Lo) m3/h
36/32/29
Indoor noise level (Hi/Mi/Lo) dB(A)
815X280X195
Dimension (W*H*D) mm
Indoor unit 915X360X275
Packing (W*H*D) mm
Net/Gross weight Kg 10.5/13.5
YDK24-6H
Model
Dimension(W*H*D) mm 780X540X250
Outdoor unit Packing (W*H*D) mm 910X575X335
Net/Gross weight Kg 36/40
730
Refrigerant type R407C g
2.8
Design pressure MPa
Operation temp ℃
17-30
Ambient temp ℃ 17-45
★1 The noise date is base on anechoic chamber, during actual operation, these values are normally somewhat different as a result of ambient
condition.
3.Dimensions
3.1 Indoor unit
MSG-05/07/09C(H)R(N2),MSG-12C(H)R
280
3.5 Outdoor unit
Valve
. 4 way valve
Compressor
Valve Capillary
Valve
Compressor
Valve Capillary
5.Operation limits
5.1Cooling operation
Outdoor unit air temp.℃ DB
45
DRY COOLING
40
35
30
25
20
10 15 20 25 30 35 40
Indoor air temp. ℃ DB
Note : The chart is the result from the continuous operation under constant air
temperature
conditions. However, excludes the initial pull-down stage.
5.2Heating operation
Indoor air temp. ℃ DB
30
25
20
15
10
-5 5 15 25
Outdoor unit air temp.℃ DB
Note : The chart is the result from the continuous operation under constant air
temperature conditions. However, excludes the initial pull-down stage.
6.2.2 ACE-G300LH
7.Troubleshooting
7.1 For all cooling only model
Failure phenomenon Operation lamp Timer lamp
Indoor fan speed has been out of control for over 1 minute ☆ X
Indoor room temp. or evaporator sensor is open circuit or short
☆ On
circuit
Over current protection of the compressor occurs 4 times X ☆
EEROM error On ☆
No over-zero signal ☆ ☆
Extinguish
☆ Flash at 5Hz
7.2 For all heat pump model
Failure phenomenon Operation lamp Timer lamp Defrosting lamp
Over current protection of the compressor occurs 4 times ☆ X ☆
Indoor fan speed has been out of control for over 1 minute X ☆ ☆
No over-zero signal ☆ ☆ ☆
Temp. sensor on indoor evaporator is open circuit or short circuit X X ☆
Indoor room temp. sensor is open circuit or short circuit X ☆ X
EEROM error On ☆ X
Extinguish
☆ Flash at 5Hz
8 Electronic function
8.1 Electric Control working environment
8.1.1 input voltage: 175~253V
8.1.2 Input power frequency:50Hz
8.1.3 Ambient temperature: -7C~+43C
8.1.4 Indoor fan normal working amp is less than 1A,
8.1.5 Outdoor fan. Normal working amp is less than 1.5A
8.1.6 Four-way valve normal working amp is less than 1A.
8.1.7 Swing motor: DC12V.
8.1.8 Compressor: single-phase power supply. Its normal working amp is less than 15A
8.2 Proper symbols and their meanings:
TA: Indoor ambient temperature
TE: Indoor evaporator temperature
TS: Setting temperature through the remote controller
I3sec: Self-protection amp of compressor, continue three seconds until turns off the
compressor.
I5MIN: Self-protection amp of compressor, continue five minutes until turns off the
compressor.
IFAN: Self-protection amp of outdoor fan/indoor fans when they change from higher wind
to lower wind.
IRESTORE: Amp self-protection return value
THDEFROST: High wind, defrosting temperature difference
TMDEFROST: Middle wind, defrosting temperature difference
TLDEFROST: Low wind, defrosting temperature difference
TE1: Anti-cold wind, from Fan Off to Breeze temperature
TE2: Anti-cold wind, from Breeze to Setting Fan Speed temperature
TE3: Anti-cold wind, from Setting Fan Speed to Breeze temperature
TE4: Anti-cold wind, from Breeze to Fan Off temperature
TE5: Evaporator low temperature protection entering temperature
TE6: Evaporator low temperature protection restoring temperature
TE7: Evaporator high temperature protection, compressor off temperature
TE8: Evaporator high temperature protection, fan off temperature
TE9: Evaporator high temperature protection, restoring temperature
I< IRESTORE On On On
If compressor turns off for continuously 4 times due to current protection in 5
minutes from Compressor On, the unit stops and LED displays failure information
and can’t returns to normal operation automatically.
T>5℃ High
Temp. down T> 3℃ High
1℃<T<3℃ Med.
T<1℃ Low
T<Ts+3 On On
Room temp. down T< Ts+2 On On
TE1<T<TE2 Breeze
TE3<T<TE4 Breeze
T<TE4 Off
8.8.5 Auto wind at heating mode
Condition Indoor fan speed
T=Indoor Temp.-Setting Temp.
Room temp. up T<2℃ High
T>2℃ Med.
Room temp. down T> 0℃ Med.
T<0℃ High
8.8.6 Indoor evaporator high-temperature protection at heating mode
Condition Compressor Outdoor fan
T= Indoor exchanger temp.
Indoor exchanger temp. up T<TE8 On On
TE8<T<TE7 On Off
T<TE9 On On
8.8.7. The louver opens to Standard Angle ANGLHEAT when power is on for the first time
8.9 Defrosting operation (Available for heating only).
8.9.1 Defrosting condition: Defrosting starts when either of the following ①&②:
① A and B are satisfied:
A: The compressor keeps running for 40 minutes or more.
B: The temperature difference of evaporator and room temperature meets one of
the following:
Temp. of evaporator---room temp.
℃
Fan speed is high ≤THDEFROST
Fan speed is mid ≤TMDEFROST
Fan speed is low ≤TLDEFROST
Breeze Meet only if it is Breeze
② Calculate from the end of latest defrost, evaporator high temp. protection only
closes outdoor fan with the compressor still running. Add up to 90 minutes.
8.9.2 Defrosting time
If the temp. difference condition ① is satisfied for less than 40 minutes, this can be
regarded as severe frosting. The defrosting time is 10 minutes.
If the temp. difference condition ② is satisfied for more than 40 minutes, the
defrosting time is 6 minutes.
If the temp. difference condition ① is satisfied out of 40 minutes, generally the
defrosting time is 6 minutes, after three continuous 6-minute defrost, the fourth
should be 10 minutes defrost. The circulation is as following:
→6-minute defrost → 6-minute defrost→6-minute defrost→10-minute
defrost→
45S 25S
Compressor
Indoor Fan
10S
8.9.7 Turn into heating mode, turn off the heating mode in 7 minutes.
ACE-G300LH
I3SEC 14.5A
I5MIN 13.5A
IFAN 9.5A
IRESTORE 8.5A
IDEFROST 6.5A
TE1 34℃
TE2 37℃
TE3 33℃
TE4 22℃
TE5 2℃
TE6 7℃
TE7 62℃
TE8 56℃
TE9 50℃
ANGLCOOL 40°
ANGLHEAT 197°
ANGLOFF 100°
THDEFROSt 17C
TMDEFROSt 18C
TLDEFROSt 19C
Exploded View Parts for Model ACE-G300LH 220--240V,50Hz : Indoor Unit
22
21
20
19
18 23
17
16
24
12
11 25
10
9
4
3 15
2 14
13
33 32
1 34 31
26
7 8
27
6
28 29
5 30