Marine Offshore
Marine Offshore
Marine Offshore
Additionally, our production facilities (in Poland, Serbia and Ukraine), the Bukowno
‑Poland recycling plant and commercial companies (responsible for the geo-regional
distribution of products) demonstrate a significant development potential. This is
also true in the case of our modern fire test laboratory in Krakow-Wielicka plant,
which performs several hundred flammability pre-tests annually, and a laboratory
of high and extra high voltages in Bydgoszcz.
TELE-FONIKA Kable
Central Europe GmbH
Hilden (Germany)
4
* JDR Cable Systems Ltd. (Sales Representative) United States. UK
Krakow-Wielicka plant – production of PVC or XLPE in- Bukowno-Poland plant (recycling of cable waste) – with
sulated 1 kV cables with copper or aluminium conductor, the recycling capacity of approx. 10 thousand tons of ca-
screened or armoured types, fire resistant and halogen ble waste per year. This allows for the recovery of frac-
free cables, overhead conductors as well as rubber in- tions from individual materials with purity of over 99.5%
sulated and/or rubber sheathed cables with voltage up
Fire Test Laboratory in the Krakow-Wielicka produc-
to 30 kV for heavy industry, signaling and control cables
tion plant – equipped with special apparatus that en-
for special applications
ables to provide flame propagation test on bundled
Krakow-Bieżanow plant – production of PCV or XLPE cables, smoke density test as well as circuit integrity
insulated copper wires and cables up to 1 kV, halogen test with water or mechanical shock, test for corrosive
free and fire resistant types and copper or silver-copper gases emission
(Cu-Ag) overhead conductors for railway traction.
Laboratory of High and Extra Voltages in the production
Bydgoszcz plant – the largest in Europe production plant in Bydgoszcz – equipped with 4 Faraday cages and
center of medium, high and extra hight voltage cables research filed for qualification tests for cables and sys-
with voltage up to 500 kV tems up to 500 kV
Myślenice plant – production copper and fiber optic tel- JDR Cable Systems – as a result of acquiring JDR Cable
ecommunication cables, data telecommunication cables Systems Limited, TFKable has expanded its assets with
and automotive wires two UK production facilities. JDR manufactures subma-
rine power cables as well as subsea umbilical cables con-
Zajecar plant (Serbia) – production of low and medium
sisting of components for power distribution, data trans-
voltage cables, signaling and control cables, telecommu-
fer, monitoring and remote control, of offshore facilities.
nication cables, as well as halogen-free cables and wires
Additionally, our sales portfolio has been extended by
Czernihov plant (Ukraine) – production of copper wires offshore installation and maintenance services, located
and cables up to 1 kV, fire resistant and flame retardant in JDR’s service centres in the United States, UK, ensur-
cables as well as insulated overhead aluminium conduc- ing constant support for our business partners
tors
Table of contents
9 Marine cables
BS6883/BS7917 (UKOOA)
NEK606
181 RFOU (i) S1/S5 & RFOU (i) EMC 150/250 (300) V EPR/EPR/TCWB/EVA
185 RFOU (c) S2/S6 & RFOU (c) EMC 150/250 (300) V EPR/EPR/TCWB/EVA
189 BFOU (i) S3/S7 & BFOU (i) EMC 150/250 (300) V MGT/EPR/EPR/TCWB/EVA
193 BFOU (c) S4/S8 & BFOU (c) EMC 150/250 (300) V MGT/EPR/EPR/TCWB/EVA
Technical section
Shipbuilding
Marine cables
Being offered by the TELE-FONIKA Kable since the early
90’s, marine cables have always been held as an important
product in cables portfolio. Years of experience, resulting
from frequent contacts with European and Far Eastern
shipyards, led to the development of light and compact
cable designs characterised by high flexibility facilitating
allow for easy installation in severely limited spaces.
12 CONSTRUCTION
Conductors: Stranded flexible bare or tinned copper class 5 acc. to IEC 60228
Insulation: Halogen-free polyolefin compound type
HF 90 acc. to IEC 60092-360
Colour of insulation: Black, red, blue, white, green/yellow
Other colors available on request
CHARACTERISTIC
Maximum conductor operating temperature: +90 oC
Lowest ambient temperature for fixed -40 oC
installation:
Lowest installation temperature: -15 oC
Maximum short-circuit conductor temperature: +250 oC
Minimum bending radius for cable with overall D < 25 mm 4D
diameter (D): D > 25 mm 6D
Fire performance
Flame retardant: IEC 60332-1-2 (test for single cable)
Smoke emission: IEC 61034-1
IEC 61034-2 min. 60%
Gases evolved during combustion: IEC 60754-1: < 0.5% HCl and HBr
IEC 60754-2: pH ≥ 4.3; conductivity ≤ 10 μSmm -1
FLAMEBLOCKER
KONS 0.6/1 kV
Cu/LSOH
Applications
For fixed wiring in switchboards, control panels and other enclosures.
13
Approvals
DNV-GL, ABS
Details related to particular Approvals are informative only. Please contact manufacturer to confirm whether
the required cross-sections are covered by the Certificate.
CHARACTERISTIC
Rated voltage U0/U/ Um: AC 0.6/1 (1.2) kV
DC 0.9/1.5 kV
Test voltage: 3.5 kV
Maximum conductor operating temperature: +90 oC
15
Lowest ambient temperature for fixed installation: -40 oC
Lowest installation temperature: -15 oC
Maximum short-circuit conductor temperature: +250 oC
Minimum bending radius for cable with overall D ≤ 25 mm 4D
diameter (D): D > 25 mm 6D
Fire performance
Flame retardant: IEC 60332-1-2
IEC 60332-3-22 Category A
Smoke emission: IEC 61034-1
IEC 61034-2 min. 60%
Gases evolved during IEC 60754-1: < 0.5% HCl and HBr
combustion: IEC 60754-2: pH ≥ 4.3; conductivity ≤ 10 µSmm -1
Applications
For fixed marine installations in all areas and open deck in ships.
Approvals
DNV-GL, ABS, LR, PRS, BV, RINA
Details related to particular Approvals are informative only. Please contact manufacturer to confirm whether
the required cross-sections are covered by the Certificate.
n × mm 2 mm kg/km
16 1 × 1 RF – 4.6 – 29
1 × 1 RM – 4.7 – 31
1 × 1.5 RF – 4.9 – 35
1 × 1.5 RM – 5 – 37
1 × 2.5 RF – 5.4 – 47
1 × 2.5 RM – 5.4 – 49
1 × 4 RF – 5.9 – 62
1 × 4 RM – 5.9 – 65
1 × 6 RF – 6.4 – 82
1 × 6 RM – 6.5 – 87
1 × 10 RF – 7.4 – 123
1 × 10 RM – 7.2 – 126
1 × 16 RF – 8.7 – 184
1 × 16 RM – 8.4 – 188
1 × 25 RF – 10.5 – 276
1 × 25 RM – 10.3 – 289
1 × 35 RF – 11.7 – 373
1 × 35 RM – 11.6 – 389
1 × 50 RF – 13.6 – 533
1 × 50 RM – 13.1 – 527
1 × 70 RF – 15.8 – 739
1 × 70 RM – 14.8 – 738
1 × 95 RF – 18.1 – 959
1 × 95 RM – 17 – 1,000
1 × 120 RF – 19.4 – 1,197
1 × 120 RM – 18.6 – 1,243
1 × 150 RF – 21.8 – 1,494
1 × 150 RM – 20.6 – 1,532
1 × 185 RF – 24.7 – 1,825
1 × 185 RM – 22.9 – 1,907
1 × 240 RF – 26.6 – 2,347
1 × 240 RM – 25.8 – 2,458
FLAMEBLOCKER
NKOXS 0.6/1 kV
Cu/XLPE/LSOH
Electrical data
Conductor class 2 Conductor class 5
Current ratings
Current ratings acc. to IEC 60092-352 based on ambient air temperature of 45ºC
mm 2 A A A
1 18 15 13
FLAMEBLOCKER
NKOXS 0.6/1 kV
Cu/XLPE/LSOH
1.5 23 20 16
2.5 40 26 21
4 51 34 28
24 6 52 44 36
10 72 61 50
16 96 82 67
25 127 108 89
35 157 133 110
50 196 167 137
70 242 206 169
95 293 249 205
120 339 288 237
150 389 331 272
185 444 377 311
240 522 444 365
300 601 511 421
1 mm 2 1.5 mm 2 2.5 mm 2
A A A
5 10.5 12 16
7 9 10 15
10 8 9 13
12 8 9 12
16 7 8 11
19 7 7 10
20 7 7 10
24 6 6.5 9.5
27 6 6.5 9
30 6 6 9
37 5 6 8
FLAMEBLOCKER
NKOXS 0.6/1 kV
Cu/XLPE/LSOH
Ambient temperature oC 35 40 45 50 55 60 65 70 75 80
Correction factors 1.10 1.05 1.00 0.94 0.88 0.82 0.74 0.67 0.58 0.47
Cross-section in mm 2 Maximum short circuit current Maximum short circuit Maximum short circuit current rating
rating for 1 s, in kA current rating for 3 s, in kA for 5 s, in kA
For 0.6/1 kV cable and maximum normal operating temperature +90 oC, short circuit temperature up to 250 oC.
FLAMEBLOCKER NKOXSekw
FLAMEBLOCKER NKOXSekw EMC
Cu/XLPE/LSOH/CWB/LSOH 0.6/1 kV
Cu/XLPE/LSOH/CWB/LSOH EMC 0.6/1 kV
IEC 60092-353
CONSTRUCTION
Conductors: •• Circular stranded bare or tinned copper class 2 (RM) 1 to 6mm 2
•• Circular compacted stranded bare or tinned copper class 2 (RM) 10 to
300 mm 2
•• Circular stranded bare or tinned copper class 5 (RF)
•• Sector shaped compacted stranded class 2 (SM) 35 to 300 mm 2
or sector stranded flex (SF) 70 to 150 mm 2
Acc. to IEC 60092-350 and IEC 60228
Insulation: ≤ 35 mm 2: cross-linked polyethylene XLPE acc. to IEC 60092-360
> 35 mm 2: cross-linked polyolefin compound HF 90 acc. to IEC 60092-360
Inner covering: Bedding tape or/and extruded layer special flame-retardant, halogen
‑free compound
Screen: NKOXSekw: Copper wire braiding
NKOXSekw EMC: Copper/polyester tape
(coverage 100%) & copper wire braid
Acc. to IEC 60092-350
Sheath: Halogen-free thermoplastic compound type SHF 1 acc. to IEC 60092-360
Colour of sheath: Black, grey or other agreed
Core identification:
Without green-yellow With green-yellow
HD 308 S2:
2-core: Blue, brown –
3-core: Brown, black, grey Green-yellow, blue, brown
4-core: Blue, brown, black, grey Green-yellow, brown, black, grey
5-core: Blue, brown, black, grey, black Green-yellow, blue, brown, black, grey
6 and more: Numbered cores Green-yellow, other cores numbered
CHARACTERISTIC
Rated voltage U0/U/ Um: AC 0.6/1 (1.2) kV
28
DC 0.6/1.5 kV
Test voltage: 3.5 kV
Maximum conductor operating temperature: +90 oC
Lowest ambient temperature for fixed installation: -40 oC
Lowest installation temperature: -15 oC
Maximum short-circuit conductor temperature: +250 oC
Minimum bending radius for: NKOXSekw: 6 × D for cables with circular copper
conductors and 8 × D for cables with sector
shaped copper conductors
NKOXSekw 8×D
EMC:
D – overall diameter of the cable
Fire performance
Flame retardant: IEC 60332-1-2
IEC 60332-3-22 Category A
Smoke emission: IEC 61034-1
IEC 61034-2 min. 60%
Gases evolved during combustion: IEC 60754-1: < 0.5% HCl and HBr
IEC 60754-2: pH ≥ 4.3; conductivity ≤ 10 μSmm -1
Applications
For fixed marine installations. Available is also version with EMC (Electro Magnetic Compatibility) protection.
Approvals
DNV-GL, ABS, LR, PRS, BV, RINA
29
Details related to particular Approvals are informative only. Please contact manufacturer to confirm whether
the required cross-sections are covered by the Certificate.
Number and cross- Approximate overall diameter Approximate net weight of cables
‑sectional area of
Extruded Tape Extruded bedding Extruded Tape Extruded bedding
conductor
bedding bedding EMC bedding bedding EMC
n × mm 2 mm kg/km
1 × 1 RF 6.2 7 7.6 66 73 95
1 × 1 RM 6.3 7.1 7.7 68 75 97
1 × 1.5 RF 6.5 7.3 7.9 73 79 103
1 × 1.5 RM 6.6 7.4 8 75 81 105
1 × 2.5 RF 7 7.8 8.4 91 91 123
1 × 2.5 RM 7 7.8 8.4 93 93 125
1 × 4 RF 7.5 8.3 8.9 107 113 141
1 × 4 RM 7.5 8.3 8.9 110 116 144
1 × 6 RF 8 8.8 9.6 128 133 174
1 × 6 RM 8.1 8.9 9.7 133 138 180
1 × 10 RF 9.2 10 10.6 181 186 222
1 × 10 RM 9 9.8 10.4 184 188 223
1 × 16 RF 10.3 11.1 11.7 246 250 291
1 × 16 RM 10 10.8 11.4 250 254 294
1 × 25 RF 12.9 13.1 13.7 377 357 416
1 × 25 RM 12.7 12.9 13.5 390 370 428
1 × 35 RF 13.9 14.1 14.7 481 459 514
1 × 35 RM 13.8 14 14.6 496 474 528
1 × 50 RF 16.6 16.8 17.4 716 689 753
1 × 50 RM 16.1 16.3 16.9 688 663 744
1 × 70 RF 18.8 19 19.6 931 900 994
1 × 70 RM 17.8 18 18.6 926 897 966
1 × 95 RF 20.9 21.1 21.7 1,171 1,134 1,219
1 × 95 RM 19.8 20 20.6 1,208 1,174 1,253
1 × 120 RF 22.4 22.6 23.2 1,443 1,404 1,495
FLAMEBLOCKER NKOXSekw
FLAMEBLOCKER NKOXSekw EMC
Cu/XLPE/LSOH/CWB/LSOH 0.6/1 kV
Cu/XLPE/LSOH/CWB/LSOH EMC 0.6/1 kV
Number and cross- Approximate overall diameter Approximate net weight of cables
‑sectional area of
Extruded Tape Extruded bedding Extruded Tape Extruded bedding
conductor
bedding bedding EMC bedding bedding EMC
30 1 × 120 RM
1 × 150 RF
21.6
24.8
21.8
25
22.4
25.6
1,467
1,750
1,429
1,726
1,536
1,827
1 × 150 RM 23.6 23.8 24.4 1,784 1,742 1,838
1 × 185 RF 27.5 27.7 28.5 2,100 2,078 2,207
1 × 185 RM 25.7 25.9 26.7 2,175 2,129 2,247
1 × 240 RF 29.4 29.6 30.2 2,658 2,604 2,727
1 × 240 RM 28.6 28.8 29.4 2,766 2,714 2,833
1 × 300 RF 33.4 33.6 34.2 3,281 3,217 3,359
1 × 300 RM 30.8 31 31.6 3,369 3,312 3,441
2 × 1 RF 9 9.8 10.4 128 117 168
2 × 1 RM 9.1 9.9 10.5 131 119 172
2 × 1.5 RF 9.6 10.4 11 151 130 194
2 × 1.5 RM 9.7 10.5 11.1 156 133 198
2 × 2.5 RF 10.6 11.4 12 184 160 236
2 × 2.5 RM 10.6 11.4 12 188 163 240
2 × 4 RF 11.7 12.5 13.1 236 203 286
2 × 4 RM 11.8 12.6 13.2 244 210 303
2 × 6 RF 12.9 13.7 14.3 297 254 355
2 × 6 RM 12.9 13.7 14.3 307 264 365
2 × 10 RF 15.3 16.1 16.7 461 387 537
2 × 10 RM 15 15.8 16.4 462 392 537
2 × 16 RF 17.8 18.6 19.2 643 535 730
2 × 16 RM 17.2 18 18.6 641 543 706
2 × 25 RF 22.1 22.1 22.9 975 842 1,026
2 × 25 RM 21.8 21.8 22.6 974 846 1,044
2 × 35 RF 24.4 24.4 25.2 1,224 1,062 1,300
2 × 35 RM 24.1 24.1 24.9 1,246 1,089 1,322
2 × 50 RF 28.6 28.6 29.4 1,719 1,498 1,786
2 × 50 RM 27.5 27.5 28.3 1,643 1,439 1,737
3 × 1 RF 9.4 10.2 10.8 140 132 187
3 × 1 RM 9.6 10.4 11 150 135 193
3 × 1.5 RF 10 10.8 11.4 167 155 211
FLAMEBLOCKER NKOXSekw
FLAMEBLOCKER NKOXSekw EMC
Cu/XLPE/LSOH/CWB/LSOH 0.6/1 kV
Cu/XLPE/LSOH/CWB/LSOH EMC 0.6/1 kV
Number and cross- Approximate overall diameter Approximate net weight of cables
‑sectional area of
Extruded Tape Extruded bedding Extruded Tape Extruded bedding
conductor
bedding bedding EMC bedding bedding EMC
3 × 1.5 RM
3 × 2.5 RF
10.2
11.1
11
11.9
11.6
12.7
173
213
160
195
218
268
31
3 × 2.5 RM 11.1 11.9 12.7 219 200 273
3 × 4 RF 12.3 13.1 13.7 277 246 333
3 × 4 RM 12.4 13.2 13.8 289 265 345
3 × 6 RF 13.5 14.3 15.5 357 315 455
3 × 6 RM 13.6 14.4 15.6 372 329 471
3 × 10 RF 16.1 16.9 17.5 545 505 625
3 × 10 RM 15.8 16.6 17.2 552 514 630
3 × 16 RF 18.8 19.6 20.2 776 707 866
3 × 16 RM 18.2 19 19.6 781 720 869
3 × 25 RF 23.4 23.4 24.4 1,179 1,062 1,245
3 × 25 RM 23 23 24 1,212 1,099 1,277
3 × 35 RF 25.8 25.8 26.8 1,526 1,385 1,599
3 × 35 RM 25.5 25.5 26.5 1,566 1,428 1,638
3 × 50 RF 30.5 30.5 31.3 2,150 1,957 2,221
3 × 50 RM 29.3 29.3 30.1 2,105 1,926 2,173
3 × 70 RF 35.2 35 36.2 2,918 2,644 3,047
3 × 70 RM 33 32.8 34 2,856 2,619 2,949
3 × 70SF 31 30.8 32 2,913 2,466 3,001
3 × 70 SM 29.5 29.3 30.5 2,829 2,448 2,912
3 × 95 RF 39.9 39.7 41.1 3,733 3,380 3,895
3 × 95 RM 37.4 37.2 38.6 3,781 3,475 3,905
3 × 95SF 33.8 33.6 35 3,682 3,143 3,794
3 × 95 SM 32.6 32.4 33.8 3,738 3,248 3,846
3 × 120 RF 43.5 43.3 44.5 4,734 4,335 4,857
3 × 120 RM 41.7 41.5 42.7 4,760 4,394 4,930
3 × 120SF 38.3 38.1 39.3 4,773 4,067 4,880
3 × 120 SM 36.3 36.1 37.3 4,702 4,095 4,856
3 × 150 RF 49.2 48.6 50.2 5,916 5,365 6,055
3 × 150 RM 46.5 45.7 47.5 5,875 5,367 6,059
3 × 150SF 42.9 42.1 43.9 6,000 5,053 6,121
FLAMEBLOCKER NKOXSekw
FLAMEBLOCKER NKOXSekw EMC
Cu/XLPE/LSOH/CWB/LSOH 0.6/1 kV
Cu/XLPE/LSOH/CWB/LSOH EMC 0.6/1 kV
Number and cross- Approximate overall diameter Approximate net weight of cables
‑sectional area of
Extruded Tape Extruded bedding Extruded Tape Extruded bedding
conductor
bedding bedding EMC bedding bedding EMC
32 3 × 150 SM
3 × 185 RF
40.8
55
40
54.4
41.8
56.2
5,859
7,184
5,024
6,501
5,973
7,368
3 × 185 RM 51.2 50.6 52.4 7,218 6,630 7,388
3 × 240 RF 59.2 58.4 60.6 8,968 8,153 9,206
3 × 240 RM 57.6 56.8 59 9,220 8,460 9,443
4 × 1 RF 10.1 10.9 11.5 162 154 207
4 × 1 RM 10.2 11 11.6 167 158 212
4 × 1.5 RF 10.8 11.6 12.4 195 176 248
4 × 1.5 RM 10.9 11.7 12.5 202 183 255
4 × 2.5 RF 12.2 13 13.6 257 232 312
4 × 2.5 RM 12.2 13 13.6 264 239 320
4 × 4 RF 13.3 14.1 15.3 332 300 429
4 × 4 RM 13.4 14.2 15.4 346 313 444
4 × 6 RF 15.3 16.1 16.7 468 426 544
4 × 6 RM 15.4 16.2 16.8 487 464 564
4 × 10 RF 17.7 18.5 19.1 676 616 762
4 × 10 RM 17.3 18.1 18.7 685 629 750
4 × 16 RF 20.7 21.5 22.1 962 874 1,060
4 × 16 RM 20 20.8 21.4 973 893 1,048
4 × 25 RF 25.7 25.7 26.5 1,465 1,343 1,525
4 × 25 RM 25.3 25.3 26.1 1,512 1,393 1,571
4 × 35 RF 28.4 28.4 29.2 1,916 1,769 1,983
4 × 35 RM 28 28 28.8 1,971 1,830 2,037
4 × 50 RF 33.6 33.6 34.4 2,705 2,506 2,784
4 × 50 RM 32.2 32.2 33 2,653 2,471 2,728
4 × 70 RF 38.8 38.6 39.8 3,679 3,398 3,790
4 × 70 RM 36.4 36.2 37.4 3,615 3,368 3,718
4 × 70SF 35.2 35 36.2 3,670 3,210 3,799
4 × 70 SM 33.2 33 34.2 3,581 3,186 3,675
4 × 95 RF 44.7 44.5 45.7 4,864 4,507 4,991
4 × 95 RM 41.9 41.7 42.9 4,949 4,581 5,067
4 × 95SF 38.9 38.7 39.9 4,794 4,226 4,903
FLAMEBLOCKER NKOXSekw
FLAMEBLOCKER NKOXSekw EMC
Cu/XLPE/LSOH/CWB/LSOH 0.6/1 kV
Cu/XLPE/LSOH/CWB/LSOH EMC 0.6/1 kV
Number and cross- Approximate overall diameter Approximate net weight of cables
‑sectional area of
Extruded Tape Extruded bedding Extruded Tape Extruded bedding
conductor
bedding bedding EMC bedding bedding EMC
4 × 95 SM
4 × 120 RF
37.4
48.3
37.2
47.7
38.4
49.5
4,885
6,027
4,365
5,572
4,989
6,188
33
4 × 120 RM 46.3 45.7 47.5 6,095 5,678 6,301
4 × 120SF 43.6 43 44.8 6,041 5,289 6,185
4 × 120 SM 41.7 41.1 42.9 6,035 5,360 6,225
4 × 150 RF 54.2 53.6 55.4 7,468 6,904 7,649
4 × 150 RM 51.2 50.6 52.4 7,461 6,957 7,632
4 × 150SF 48.2 47.6 49.4 7,547 6,548 7,707
4 × 150 SM 46 45.4 47.2 7,418 6,584 7,570
4 × 185 RF 60.9 60.3 61.9 9,071 8,366 9,255
4 × 185 RM 56.7 56.1 57.7 9,207 8,603 9,368
4 × 240 RF 65.8 65 67 11,452 10,618 11,683
4 × 240 RM 64 63.2 65.2 11,800 11,010 12,025
5 × 1 RF 10.8 11.6 12.4 190 174 243
5 × 1 RM 11 11.8 12.6 197 186 250
5 × 1.5 RF 11.8 12.6 13.2 228 215 288
5 × 1.5 RM 12 12.8 13.4 243 223 298
5 × 2.5 RF 13.1 13.9 14.5 297 280 356
5 × 2.5 RM 13.2 14 14.6 316 289 366
5 × 4 RF 15 15.8 16.4 435 402 511
5 × 4 RM 15.2 16 16.6 454 419 530
5 × 6 RF 16.6 17.4 18.2 566 522 637
5 × 6 RM 16.7 17.5 18.3 591 546 662
5 × 10 RF 19.2 20 20.8 819 756 901
5 × 10 RM 18.8 19.6 20.4 812 772 912
5 × 16 RF 22.6 23.4 24 1,171 1,079 1,256
5 × 16 RM 21.7 22.5 23.1 1,163 1,099 1,265
5 × 25 RF 28.2 28.2 29 1,793 1,610 1,860
5 × 25 RM 27.7 27.7 28.5 1,852 1,675 1,917
5 × 35 RF 31.2 31.2 32 2,317 2,092 2,420
5 × 35 RM 30.8 30.8 31.6 2,386 2,167 2,459
5 × 50 RF 37.1 36.9 38.1 3,329 3,000 3,434
FLAMEBLOCKER NKOXSekw
FLAMEBLOCKER NKOXSekw EMC
Cu/XLPE/LSOH/CWB/LSOH 0.6/1 kV
Cu/XLPE/LSOH/CWB/LSOH EMC 0.6/1 kV
Number and cross- Approximate overall diameter Approximate net weight of cables
‑sectional area of
Extruded Tape Extruded bedding Extruded Tape Extruded bedding
conductor
bedding bedding EMC bedding bedding EMC
34 5 × 50 RM
5 × 70 RF
35.6
43.3
35.4
43.1
36.6
44.3
3,236
4,660
2,935
4,222
3,366
4,782
5 × 70 RM 40.6 40.4 41.6 4,530 4,149 4,644
6 × 1.5 RF 12.7 13.5 14.1 264 252 321
6 × 1.5 RM 12.9 13.7 14.3 275 262 333
6 × 2.5 RF 14.7 15.5 16.1 394 366 449
6 × 2.5 RM 14.8 15.6 16.2 406 378 481
7 × 1 RF 11.8 12.6 13.2 222 212 282
7 × 1 RM 12 12.8 13.4 237 219 291
7 × 1.5 RF 12.7 13.5 14.1 270 258 328
7 × 1.5 RM 12.9 13.7 14.3 282 269 340
7 × 2.5 RF 14.7 15.5 16.1 406 378 461
7 × 2.5 RM 14.8 15.6 16.2 420 392 494
8 × 1.5 RF 14 14.8 15.4 348 326 400
8 × 1.5 RM 14.2 15 15.6 362 339 415
9 × 1.5 RF 14.9 15.7 16.3 383 350 459
9 × 1.5 RM 15.1 15.9 16.5 399 364 475
10 × 1 RF 15 15.8 16.4 350 322 426
10 × 1 RM 15.3 16.1 16.7 363 333 439
10 × 1.5 RF 16.2 17 17.8 431 396 500
10 × 1.5 RM 16.4 17.2 18 448 411 518
10 × 2.5 RF 18.3 19.1 19.7 556 529 645
10 × 2.5 RM 18.4 19.2 19.8 576 548 664
12 × 1 RF 15.4 16.2 16.8 375 369 452
12 × 1 RM 15.7 16.5 17.1 389 381 468
12 × 1.5 RF 16.8 17.6 18.2 473 440 535
12 × 1.5 RM 17.1 17.9 18.5 493 459 557
12 × 2.5 RF 18.8 19.6 20.2 608 584 699
12 × 2.5 RM 18.9 19.7 20.3 631 607 722
14 × 1.5 RF 17.6 18.4 19 513 480 599
14 × 1.5 RM 17.9 18.7 19.3 536 502 623
16 × 1 RF 17 17.8 18.4 467 440 531
FLAMEBLOCKER NKOXSekw
FLAMEBLOCKER NKOXSekw EMC
Cu/XLPE/LSOH/CWB/LSOH 0.6/1 kV
Cu/XLPE/LSOH/CWB/LSOH EMC 0.6/1 kV
Number and cross- Approximate overall diameter Approximate net weight of cables
‑sectional area of
Extruded Tape Extruded bedding Extruded Tape Extruded bedding
conductor
bedding bedding EMC bedding bedding EMC
16 × 1 RM
16 × 1.5 RF
17.3
18.4
18.1
19.2
18.7
19.8
486
559
457
544
550
647
35
16 × 1.5 RM 18.7 19.5 20.1 585 569 675
16 × 2.5 RF 20.9 21.7 22.3 765 720 864
16 × 2.5 RM 20.9 21.7 22.3 794 749 893
19 × 1 RF 17.8 18.6 19.2 508 479 594
19 × 1 RM 18.2 19 19.6 529 518 617
19 × 1.5 RF 19.5 20.3 20.9 642 607 715
19 × 1.5 RM 19.8 20.6 21.2 672 635 747
19 × 2.5 RF 21.9 22.7 23.5 866 818 960
19 × 2.5 RM 22 22.8 23.6 902 854 996
20 × 1 RF 18.5 19.3 19.9 532 516 621
20 × 1 RM 19 19.8 20.4 575 538 647
20 × 1.5 RF 20.4 21.2 21.8 674 631 771
20 × 1.5 RM 20.7 21.5 22.1 706 661 804
20 × 2.5 RF 23.1 23.9 24.5 922 864 1,029
20 × 2.5 RM 23.2 24 24.6 959 901 1,067
24 × 1 RF 20.5 21.3 21.9 629 590 726
24 × 1 RM 21 21.8 22.4 657 634 756
24 × 1.5 RF 22.6 23.4 24 794 745 880
24 × 1.5 RM 23 23.8 24.4 833 782 920
24 × 2.5 RF 25.7 26.5 27.1 1086 1021 1,184
24 × 2.5 RM 25.7 26.5 27.1 1130 1,065 1,228
27 × 1 RF 20.9 21.7 22.3 668 630 766
27 × 1 RM 21.4 22.2 22.8 697 677 798
27 × 1.5 RF 23 23.8 24.4 846 799 933
27 × 1.5 RM 23.4 24.2 24.8 889 840 997
27 × 2.5 RF 26.2 27 27.6 1165 1,103 1,294
27 × 2.5 RM 26.3 27.1 27.7 1216 1,153 1,345
30 × 1 RF 21.6 22.4 23.2 711 692 823
30 × 1 RM 22.1 22.9 23.7 763 722 857
30 × 1.5 RF 23.8 24.6 25.2 904 876 1,014
FLAMEBLOCKER NKOXSekw
FLAMEBLOCKER NKOXSekw EMC
Cu/XLPE/LSOH/CWB/LSOH 0.6/1 kV
Cu/XLPE/LSOH/CWB/LSOH EMC 0.6/1 kV
Number and cross- Approximate overall diameter Approximate net weight of cables
‑sectional area of
Extruded Tape Extruded bedding Extruded Tape Extruded bedding
conductor
bedding bedding EMC bedding bedding EMC
36 30 × 1.5 RM
30 × 2.5 RF
24.2
27.1
25
27.9
25.6
28.5
951
1,252
921
1,219
1,062
1,384
30 × 2.5 RM 27.1 27.9 28.5 1,307 1,273 1,439
37 × 1 RF 23.3 24.1 24.7 842 801 950
37 × 1 RM 23.9 24.7 25.3 882 858 992
37 × 1.5 RF 25.7 26.5 27.1 1,071 1,021 1,169
37 × 1.5 RM 26.1 26.9 27.5 1,128 1,076 1,256
37 × 2.5 RF 29.3 30.1 30.7 1,499 1,432 1,610
37 × 2.5 RM 29.3 30.1 30.7 1,566 1,500 1,678
Electrical data
Conductor class 2 Conductor class 5
1 mm 2 1.5 mm 2 2.5 mm 2
A A A
5 10.5 12 16
7 9 10 15
10 8 9 13
12 8 9 12
16 7 8 11
19 7 7 10
20 7 7 10
24 6 6.5 9.5
27 6 6.5 9
30 6 6 9
37 5 6 8
38 Ambient temperature oC 35 40 45 50 55 60 65 70 75 80
Correction factors 1.10 1.05 1.00 0.94 0.88 0.82 0.74 0.67 0.58 0.47
For 0.6/1 kV cable and maximum normal operating temperature +90 oC, short circuit temperature up to 250 oC.
FLAME-X 950
NKOGs 0.6/1 kV
Cu/SiR/LSOH 0.6/1 kV
IEC 60092-353
CHARACTERISTIC
Rated voltage U0/U/ Um: AC 0.6/1 (1.2) kV
DC 0.9/1.5 kV
Test voltage: 3.5 kV
Maximum conductor operating temperature: +95 oC
Lowest ambient temperature for fixed installation: -40 oC
FLAME-X 950
NKOGs 0.6/1 kV
Cu/SiR/LSOH 0.6/1 kV
40
Fire performance
Fire resistant : IEC 60331-21: for cable diameters ≤ 20 mm,
IEC 60331-1: for cable diameters > 20 mm
Flame retardant: IEC 60332-1-2
IEC 60332-3-22 Category A
Smoke emission: IEC 61034-1
IEC 61034-2 min. 60%
Gases evolved during combustion: IEC 60754-1: < 0.5% HCl and HBr
IEC 60754-2: pH ≥ 4.3; conductivity ≤ 10 μSmm -1
Applications
For fixed marine installations, where circuit integrity is required under fire conditions.
Approvals
DNV-GL, ABS, LR, PRS, BV, RINA
Details related to particular Approvals are informative only. Please contact manufacturer to confirm whether
the required cross-sections are covered by the Certificate.
Number and cross Approximate overall diameter Approximate net weight of cables
‑sectional area of Extruded Tape Extruded Tape
conductor bedding bedding bedding bedding
n × mm 2 mm kg/km
1 × 1 RM – 5.3 – 39
FLAME-X 950
NKOGs 0.6/1 kV
Cu/SiR/LSOH 0.6/1 kV
Number and cross Approximate overall diameter Approximate net weight of cables
‑sectional area of Extruded Tape Extruded Tape
conductor bedding bedding bedding bedding
1 × 1.5 RM – 5.6 – 46
1 × 2.5 RM – 6 – 58
1 × 4 RM
1 × 6 RM
–
–
6.5
7.1
–
–
76
99
41
1 × 10 RM – 8.2 – 147
1 × 16 RM – 9.2 – 208
1 × 25 RM – 11.1 – 316
1 × 35 RM – 12.2 – 413
1 × 50 RM – 14.1 – 555
1 × 70 RM – 15.4 – 755
1 × 95 RM – 18 – 1,034
1 × 120 RM – 19.6 – 1,279
1 × 150 RM – 21.6 – 1,564
1 × 185 RM – 23.7 – 1,941
1 × 240 RM – 26.8 – 2,507
1 × 300 RM – 29.2 – 3,116
2 × 1 RM 9.5 10.3 128 92
2 × 1.5 RM 10.1 10.9 150 107
2 × 2.5 RM 11 11.8 187 134
2 × 4 RM 12.2 13 244 177
2 × 6 RM 13.3 14.1 308 225
2 × 10 RM 15.2 16 431 324
2 × 16 RM 18 18.2 636 460
2 × 25 RM 21.8 21.8 819 756
2 × 35 RM 24.1 24.1 1,056 986
2 × 50 RM 27.7 27.7 1,398 1,316
3 × 1 RM 10 10.8 144 114
3 × 1.5 RM 10.7 11.5 171 135
3 × 2.5 RM 11.8 12.6 222 178
3 × 4 RM 12.9 13.7 288 232
3 × 6 RM 14.1 14.9 370 300
3 × 10 RM 16.1 16.9 527 438
3 × 16 RM 19 19.2 783 631
3 × 25 RM 23.1 23.1 1,075 1,007
FLAME-X 950
NKOGs 0.6/1 kV
Cu/SiR/LSOH 0.6/1 kV
Number and cross Approximate overall diameter Approximate net weight of cables
‑sectional area of Extruded Tape Extruded Tape
conductor bedding bedding bedding bedding
3 × 35 RM 25.6 25.6 1,401 1,326
3 × 50 RM 29.6 29.6 1,879 1,791
42 3 × 70 RM
3 × 95 RM
32.9
38.4
32.7
38.2
2,553
3,488
2,436
3,351
3 × 120 RM 41.6 41.4 4,264 4,114
3 × 150 RM 46.6 46 5,281 5,060
3 × 185 RM 51.1 50.5 6,519 6,276
3 × 240 RM 58 57.2 8,425 8,115
4 × 1 RM 10.9 11.7 169 138
4 × 1.5 RM 11.8 12.6 207 171
4 × 2.5 RM 12.8 13.6 264 219
4 × 4 RM 14.1 14.9 346 290
4 × 6 RM 15.6 16.4 456 386
4 × 10 RM 17.8 18.6 654 565
4 × 16 RM 21 21.2 974 818
4 × 25 RM 25.5 25.5 1,365 1,290
4 × 35 RM 28.3 28.3 1,787 1,703
4 × 50 RM 33 32.8 2,419 2,302
4 × 70 RM 36.4 36.2 3,279 3,149
4 × 95 RM 42.5 42.3 4,478 4,325
4 × 120 RM 46.5 45.9 5,547 5,326
4 × 150 RM 51.8 51.2 6,820 6,573
4 × 185 RM 57 56.2 8,463 8,159
4 × 240 RM 64.6 63.8 10,926 10,580
5 × 1 RM 12 12.8 206 174
5 × 1.5 RM 12.8 13.6 247 209
5 × 2.5 RM 14 14.8 318 271
5 × 4 RM 15.6 16.4 428 369
5 × 6 RM 17.3 18.1 564 491
5 × 10 RM 19.4 20.2 798 705
5 × 16 RM 23 23.2 1,191 1,026
5 × 25 RM 28.2 28.2 1,657 1,574
5 × 35 RM 31.2 31.2 2,172 2,079
5 × 50 RM 36.4 36.2 2,937 2,806
FLAME-X 950
NKOGs 0.6/1 kV
Cu/SiR/LSOH 0.6/1 kV
Number and cross Approximate overall diameter Approximate net weight of cables
‑sectional area of Extruded Tape Extruded Tape
conductor bedding bedding bedding bedding
5 × 70 RM 40.4 40 4,008 3,844
6 × 1.5 RM 13.9 14.7 290 249
6 × 2.5 RM
7 × 1 RM
15.4
13
16.2
13.8
382
247
331
211
43
7 × 1.5 RM 13.9 14.7 299 257
7 × 2.5 RM 15.4 16.2 398 347
8 × 1.5 RM 14.9 15.7 338 294
9 × 1.5 RM 16 16.8 391 327
10 × 1 RM 16.5 17.3 355 297
10 × 1.5 RM 17.8 18.6 438 371
10 × 2.5 RM 19.6 20.4 573 490
12 × 1 RM 17 17.8 392 338
12 × 1.5 RM 18.4 19.2 486 424
12 × 2.5 RM 20.4 21.2 650 573
14 × 1.5 RM 19.3 20.1 543 479
16 × 1 RM 19 19.8 497 440
16 × 1.5 RM 20.5 21.3 618 553
16 × 2.5 RM 22.6 23.4 820 739
19 × 1 RM 20.2 21 566 507
19 × 1.5 RM 21.6 22.4 695 627
19 × 2.5 RM 24 24.8 939 856
20 × 1 RM 21.1 21.9 604 533
20 × 1.5 RM 22.9 23.7 754 671
20 × 2.5 RM 25.1 25.9 1,001 900
24 × 1 RM 23.6 24.4 717 637
24 × 1.5 RM 25.4 26.2 883 790
24 × 2.5 RM 28.1 28.9 1,191 1,077
27 × 1 RM 24.1 24.9 774 697
27 × 1.5 RM 26.1 26.9 968 880
27 × 2.5 RM 29 29.8 1,310 1,201
30 × 1 RM 25 25.8 838 760
30 × 1.5 RM 27 27.8 1,050 960
30 × 2.5 RM 30 30.8 1,425 1,315
37 × 1 RM 27.1 27.9 1,001 919
FLAME-X 950
NKOGs 0.6/1 kV
Cu/SiR/LSOH 0.6/1 kV
Number and cross Approximate overall diameter Approximate net weight of cables
‑sectional area of Extruded Tape Extruded Tape
conductor bedding bedding bedding bedding
37 × 1.5 RM 29.3 30.1 1,258 1,163
37 × 2.5 RM 32.7 33.3 1,730 1,595
44
Current ratings
Current ratings acc. to IEC 60092-352 based on ambient air temperature of 45ºC
mm 2 A A A
1 18 15 13
1.5 23 20 16
2.5 40 26 21
4 51 34 28
6 52 44 36
10 72 61 50
16 96 82 67
25 127 108 89
35 157 133 110
50 196 167 137
70 242 206 169
95 293 249 205
120 339 288 237
150 389 331 272
185 444 377 311
240 522 444 365
300 601 511 421
1 mm 2
1.5 mm 2 2.5 mm 2
A A A
5 10.5 12 16
7 9 10 15
10 8 9 13 45
12 8 9 12
16 7 8 11
19 7 7 10
20 7 7 10
24 6 6.5 9.5
27 6 6.5 9
30 6 6 9
37 5 6 8
46
For 0.6/1 kV cable and maximum normal operating temperature +90 oC. Short circuit temperature up to 250 oC.
FLAME-X 950 NKOGsekw 0.6/1 kV
FLAME-X 950 NKOGsekw EMC 0.6/1 kV
Cu/SiR/LSOH/CWB/LSOH 0.6/1 kV
Cu/SiR/LSOH/CWB/LSOH EMC 0.6/1 kV
IEC 60092-353
CONSTRUCTION
Conductors: Circular or circular compacted stranded
bare or tinned copper class 2 (RM)
acc. to IEC 60092-350 and IEC 60228
Insulation: Special cross-linked compound S 95
acc. to IEC 60092-360
Inner covering: Bedding tape or/and extruded layer
special flame-retardant, halogen-free
compound
Screen: NKOGsekw: copper wire braiding
NKOGsekw EMC: copper/polyester
tape (coverage 100%) & copper wire
braid
acc. to IEC 60092-350
Sheath: Halogen-free thermoplastic compound
type SHF 1 acc. to IEC 60092-360
Colour of sheath: Orange, black or other agreed
Core identification:
Without green-yellow With green-yellow
HD 308 S2:
2-core: Blue, brown –
3-core: Brown, black, grey Green-yellow, blue, brown
4-core: Blue, brown, black, grey Green-yellow, brown, black, grey
5-core: Blue, brown, black, grey, black Green-yellow, blue, brown, black, grey
7 and more: Numbered cores Green-yellow, other cores numbered
CHARACTERISTIC
Rated voltage U0/U/ Um: AC 0.6/1 (1.2) kV
48
DC 0.9/1.5 kV
Test voltage: 3.5 kV
Maximum conductor operating temperature: +95 oC
Lowest ambient temperature for fixed installation: -40 oC
Lowest installation temperature: -15 oC
Maximum short-circuit conductor temperature: +350 oC 1)
Minimum bending radius for: NKOGsekw: 6 × D
NKOGsekw EMC: 8 × D
D – overall diameter of the cable
1)
temperature applicable only to power cables and is not appropriate for tinned conductors
Fire performance
Fire resistant : IEC 60331-21: for cable diameters ≤ 20 mm,
IEC 60331-1: for cable diameters > 20 mm
Flame retardant: IEC 60332-1-2
IEC 60332-3-22 Category A
Smoke emission: IEC 61034-1
IEC 61034-2 min. 60%
Gases evolved during combustion: IEC 60754-1: < 0.5% HCl and HBr
IEC 60754-2: pH ≥ 4.3; conductivity ≤ 10 μSmm -1
Applications
For fixed marine installations, where circuit integrity is required under fire conditions.
Available is also version with EMC (Electro Magnetic Compatibility) protection.
Approvals
DNV-GL, ABS, LR, PRS, BV, RINA
49
Details related to particular Approvals are informative only. Please contact manufacturer to confirm whether
the required cross-sections are covered by the Certificate.
Number and Approximate overall diameter Approximate net weight of cables Maximum conductor
cross-sectional resistance at
Extruded Tape EMC Extruded Tape EMC
area of conductor temperature 20 oC
bedding bedding bedding bedding
n × mm 2 mm kg/km Ω/km
1 × 1 RM 6.9 7.7 8.3 83 87 122 18.1
1 × 1.5 RM 7.2 8 8.6 91 100 131 12.1
1 × 2.5 RM 7.6 8.4 9 110 113 145 7.41
1 × 4 RM 8.1 8.9 9.7 128 137 177 4.61
1 × 6 RM 8.9 9.7 10.3 162 165 203 3.08
1 × 10 RM 9.8 10.6 11.2 215 217 259 1.83
1 × 16 RM 11.4 11.6 12.4 299 285 338 1.15
1 × 25 RM 13.3 13.5 14.1 431 406 466 0.727
1 × 35 RM 14.4 14.6 15.8 531 512 628 0.524
1 × 50 RM 16.7 16.9 17.5 751 716 794 0.387
1 × 70 RM 18.2 18.4 19 964 945 1,031 0.268
1 × 95 RM 20.8 21 21.6 1,274 1,248 1,349 0.193
1 × 120 RM 22.2 22.4 23 1,533 1,503 1,593 0.153
1 × 150 RM 24.4 24.6 25.2 1,857 1,802 1,932 0.124
1 × 185 RM 26.5 26.7 27.3 2,252 2,221 2,353 0.0991
1 × 240 RM 29.6 29.8 30.4 2,861 2,821 2,941 0.0754
1 × 300 RM 32 32.2 32.8 3,508 3,434 3,596 0.0601
2 × 1 RM 10.3 11.1 11.7 171 152 224 18.1
2 × 1.5 RM 10.9 11.7 12.5 197 167 255 12.1
2 × 2.5 RM 12 12.8 13.4 244 210 303 7.41
2 × 4 RM 13 13.8 14.4 305 256 357 4.61
2 × 6 RM 14.7 15.5 16.1 424 351 481 3.08
2 × 10 RM 16.4 17.2 18 536 463 629 1.83
2 × 16 RM 19.2 19.4 20 770 664 817 1.15
2 × 25 RM 23 23 24 993 952 1,086 0.727
2 × 35 RM 25.3 25.3 26.1 1,259 1,192 1,327 0.524
FLAME-X 950 NKOGsekw 0.6/1 kV
FLAME-X 950 NKOGsekw EMC 0.6/1 kV
Cu/SiR/LSOH/CWB/LSOH 0.6/1 kV
Cu/SiR/LSOH/CWB/LSOH EMC 0.6/1 kV
Number and Approximate overall diameter Approximate net weight of cables Maximum conductor
cross-sectional resistance at
Extruded Tape EMC Extruded Tape EMC
area of conductor temperature 20 oC
bedding bedding bedding bedding
50
2 × 50 RM 29.1 29.1 29.9 1,642 1,564 1,721 0.387
3 × 1 RM 10.8 11.6 12.4 193 173 251 18.1
3 × 1.5 RM 11.7 12.5 13.1 231 212 289 12.1
3 × 2.5 RM 12.6 13.4 14 278 249 337 7.41
3 × 4 RM 14.3 15.1 15.7 407 358 463 4.61
3 × 6 RM 15.5 16.3 16.9 487 445 568 3.08
3 × 16 RM 20.4 20.6 21.2 930 852 981 1.15
3 × 25 RM 24.5 24.5 25.3 1,279 1,215 1,355 0.727
3 × 35 RM 27 27 27.8 1,616 1,573 1,719 0.524
3 × 50 RM 30.8 30.8 31.6 2,138 2,054 2,222 0.387
3 × 70 RM 34.3 33.9 35.3 2,854 2,727 2,964 0.268
3 × 95 RM 40 39.8 41.2 3,899 3,815 4,152 0.193
3 × 120 RM 43.4 43.2 44.4 4,746 4,650 4,938 0.153
3 × 150 RM 48.4 47.8 49.4 5,807 5,607 5,963 0.124
3 × 185 RM 52.9 52.3 53.9 7,081 6,876 7,265 0.0991
3 × 240 RM 59.8 59 61 9,058 8,795 9,296 0.0754
4 × 1 RM 11.9 12.7 13.3 229 214 288 18.1
4 × 1.5 RM 12.6 13.4 14 264 242 323 12.1
4 × 2.5 RM 13.6 14.4 15.6 328 299 441 7.41
4 × 4 RM 15.5 16.3 16.9 466 435 546 4.61
4 × 6 RM 17 17.8 18.4 595 533 661 3.08
4 × 10 RM 19 19.8 20.6 802 723 886 1.83
4 × 16 RM 22.2 22.4 23 1,130 1,045 1,186 1.15
4 × 25 RM 26.9 26.9 27.7 1,580 1,537 1,682 0.727
4 × 35 RM 29.7 29.7 30.5 2,031 1,980 2,112 0.524
4 × 70 RM 38.2 38 39.2 3,709 3,581 3,831 0.268
4 × 95 RM 44.3 44.1 45.3 4,961 4,861 5,156 0.193
4 × 120 RM 48.3 47.7 49.3 6,073 5,872 6,229 0.153
4 × 150 RM 53.6 53 54.6 7,391 7,182 7,576 0.124
4 × 185 RM 58.8 58 60 9,085 8,827 9,318 0.0991
4 × 240 RM 66.4 65.4 67.6 11,631 11,307 11,893 0.0754
5 × 1 RM 12.8 13.6 14.2 264 245 324 18.1
5 × 1.5 RM 13.6 14.4 15.6 313 288 425 12.1
FLAME-X 950 NKOGsekw 0.6/1 kV
FLAME-X 950 NKOGsekw EMC 0.6/1 kV
Cu/SiR/LSOH/CWB/LSOH 0.6/1 kV
Cu/SiR/LSOH/CWB/LSOH EMC 0.6/1 kV
Number and Approximate overall diameter Approximate net weight of cables Maximum conductor
cross-sectional resistance at
Extruded Tape EMC Extruded Tape EMC
area of conductor temperature 20 oC
bedding bedding bedding bedding
51
5 × 2.5 RM 15.4 16.2 16.8 440 417 520 7.41
5 × 4 RM 17 17.8 18.4 568 515 634 4.61
5 × 6 RM 18.5 19.3 19.9 694 648 786 3.08
5 × 10 RM 20.8 21.6 22.2 954 892 1,056 1.83
5 × 16 RM 24.4 24.6 25.2 1,377 1,262 1,448 1.15
5 × 25 RM 29.6 29.6 30.4 1,907 1,855 1,988 0.727
5 × 35 RM 32.6 32.6 33.4 2,456 2,395 2,545 0.524
5 × 50 RM 38.2 37.6 39.2 3,388 3,152 3,510 0.387
5 × 70 RM 42 41.8 43.2 4,501 4,359 4,709 0.268
6 × 1.5 RM 15.3 16.1 16.7 412 394 492 12.1
6 × 2.5 RM 16.6 17.4 18.2 516 470 589 7.41
7 × 1 RM 14.4 15.2 15.8 370 338 426 18.1
7 × 1.5 RM 15.3 16.1 16.7 421 403 501 12.1
7 × 2.5 RM 16.6 17.4 18.2 531 485 605 7.41
8 × 1.5 RM 16.3 17.1 17.7 461 441 544 12.1
9 × 1.5 RM 17.4 18.2 18.8 531 492 619 12.1
10 × 1 RM 17.9 18.7 19.3 496 463 586 18.1
10 × 1.5 RM 19 19.8 20.6 589 529 674 12.1
10 × 2.5 RM 21 21.8 22.4 730 676 833 7.41
12 × 1 RM 18.4 19.2 19.8 533 504 625 18.1
12 × 1.5 RM 19.8 20.6 21.2 647 610 745 12.1
12 × 2.5 RM 21.6 22.4 23 819 769 904 7.41
14 × 1.5 RM 20.7 21.5 22.1 704 666 805 12.1
16 × 1 RM 20.4 21.2 21.8 659 626 759 18.1
16 × 1.5 RM 21.7 22.5 23.3 789 748 886 12.1
16 × 2.5 RM 24 24.8 25.4 1,019 956 1,124 7.41
19 × 1 RM 21.4 22.2 22.8 738 702 822 18.1
19 × 1.5 RM 23 23.8 24.4 876 833 987 12.1
19 × 2.5 RM 25.4 26.2 26.8 1,149 1,101 1,249 7.41
20 × 1 RM 22.5 23.3 23.9 784 739 893 18.1
20 × 1.5 RM 24.1 24.9 25.5 941 876 1,047 12.1
20 × 2.5 RM 26.5 27.3 27.9 1,208 1,146 1,343 7.41
24 × 1 RM 24.8 25.6 26.4 915 871 1,026 18.1
FLAME-X 950 NKOGsekw 0.6/1 kV
FLAME-X 950 NKOGsekw EMC 0.6/1 kV
Cu/SiR/LSOH/CWB/LSOH 0.6/1 kV
Cu/SiR/LSOH/CWB/LSOH EMC 0.6/1 kV
Number and Approximate overall diameter Approximate net weight of cables Maximum conductor
cross-sectional resistance at
Extruded Tape EMC Extruded Tape EMC
area of conductor temperature 20 oC
bedding bedding bedding bedding
52
24 × 1.5 RM 26.8 27.6 28.2 1,091 1,036 1,227 12.1
24 × 2.5 RM 29.5 30.3 30.9 1,426 1,353 1,574 7.41
27 × 1 RM 25.5 26.3 26.9 984 943 1,115 18.1
27 × 1.5 RM 27.3 28.1 28.7 1,194 1,113 1,303 12.1
27 × 2.5 RM 30.2 31 31.6 1,533 1,464 1,683 7.41
30 × 1 RM 26.4 27.2 27.8 1,048 1,006 1,183 18.1
30 × 1.5 RM 28.4 29.2 29.8 1,289 1,236 1,402 12.1
30 × 2.5 RM 31.4 32.2 32.8 1,692 1,593 1,817 7.41
37 × 1 RM 28.5 29.3 29.9 1,242 1,195 1,355 18.1
Current ratings
Current ratings acc. to IEC 60092-352 based on ambient air temperature of 45ºC
54 Ambient temperature °C
Correction factors
35
1.10
40
1.05
45
1.00
50
0.94
55
0.88
60
0.82
65
0.74
70
0.67
75
0.58
80
0.47
For 0.6/1 kV cable and maximum normal operating temperature +90 oC, short circuit temperature up to 250 oC.
FLAMEBLOCKER NKOXSekw-VFD
1.8/3 kV HD
Cu/XLPE/LSOH/CWB/LSOH VFD 1.8/3 kV
IEC 60092-353
CHARACTERISTIC
Rated voltage U0/U/ Um: AC 1.8/3 (3.6) kV
Maximum conductor operating temperature: +90 oC
Fire performance
Flame retardant: IEC 60332-1-2
IEC 60332-3-22 Category A
Smoke emission: IEC 61034-2 min. 60%
Applications
For fixed installations in ships. Special cable for variable frequency drives (VFD).
n x mm 2 mm kg/km
1 × 25 RF 16.5 15.5 539 463
1 × 25 RM 16.3 15.3 531 475
1 × 35 RF 17.5 16.5 640 580
1 × 35 RM 17.4 16.4 655 594
1 × 50 RF 19.6 18.6 858 769
1 × 50 RM 19.1 18.1 827 760
1 × 70 RF 21.4 20.4 1,070 993
1 × 70 RM 20.4 19.4 1,058 986
1 × 95 RF 23.7 22.7 1,334 1,248
1 × 95 RM 22.6 21.6 1,363 1,262
1 × 120 RF 25 24 1,606 1,495
1 × 120 RM 24.2 23.2 1,624 1,536
1 × 150 RF 26.8 25.8 1,893 1,794
1 × 150 RM 25.6 24.6 1,920 1,807
3 × 25 RF 29.3 28.1 1,539 1,308
3 × 25 RM 29 27.8 1,570 1,343
FLAMEBLOCKER NKOXSekw-VFD
1.8/3 kV HD
Cu/XLPE/LSOH/CWB/LSOH VFD 1.8/3 kV
Current ratings
Current ratings acc. to IEC 60092-352 based on ambient air temperature of 45ºC
mm 2 A
25 89
35 110
50 137
70 169
95 205
120 237
150 272
Correction factors 1.10 1.05 1.00 0.94 0.88 0.82 0.74 0.67 0.58 0.47 59
Maximum short circuit 3.58 5.01 7.15 10.01 13.59 17.16 21.45
current rating for 1 s, in kA
Maximum short circuit 2.06 2.89 4.13 5.78 7.84 9.91 12.38
current rating for 3 s, in kA
Maximum short circuit 1.6 2.24 3.2 4.48 6.08 7.67 9.59
current rating for 5 s, in kA
For 1.8/3 kV cable and maximum normal operating temperature +90 oC, short circuit temperature up to 250 oC.
All the information contained in this document – including tables and diagrams – is given in good faith and believed to be correct at the
time of publication. The information does not constitute a warranty nor representation for which TELE-FONIKA Kable assumes legal
responsibility. TELE-FONIKA Kable reserves rights to introduce changes to the document at any time.
MV single-core halogen-free
shipboard power cables
NHKOXSek
Cu/XLPE/CTS/LSOH/CWB/LSOH
6/10 (12) kV
IEC 60092-354
62 CONSTRUCTION
Conductors: Round, stranded and compacted bare copper class
2 acc. to IEC 60228
Insulation: •• Extruded semi-conductive conductor screen
•• Insulation XLPE, dry cured
•• Extruded semi-conductive insulation screen,
fully bonded
Screen: •• Semi-conductive tape
•• Metallic screen, double bare copper tape
Inner covering: Halogen-free compound
Separator: Separating tape – optional
Armour (overall screen): Bare copper braid
Separator: Separating tape – optional
Outer sheath: Halogen-free compound type SHF 1
Colour of sheath: Red
CHARACTERISTIC
Maximum conductor operating +90 oC
temperature:
Maximum short-circuit +250 oC
conductor temperature:
Lowest ambient temperature -40 oC
for fixed installation:
Lowest installation 0 oC
temperature:
Minimum bending radius: 15 × D
D – overall diameter of cable
NHKOXSek
Cu/XLPE/CTS/LSOH/CWB/LSOH
6/10 (12) kV
Fire performance
Flame retardant: IEC 60332-3-22 Category A
Smoke emission: IEC 61034-2
Corrosive gas emission: IEC 60754-1: < 0.5% HCl and HBr
IEC 60754-2: pH ≥ 4.3; conductivity ≤ 10 µSmm -1
63
Applications
Used for fixed installations on board of ships laying in air, but not on open decks
Number and nominal cross-section No. × mm 2/mm 2 1 × 35/16 1 × 50/16 1 × 70/16 1 × 95/16 1 × 120/16
of the conductors
Construction data
Mechanical data
Electrical data
Maximum D.C. phase conductor Ω/km 0.524 0.387 0.268 0.193 0.153
resistance at 20 oC
Maximum A.C. phase conductor Ω/km 0.668 0.496 0.345 0.249 0.198
resistance at 90 oC
Short circuit currents
Ampacity, in free air, ambient temperature 45 oC, acc. to IEC 60092-352 Table A.4
NHKOXSek
Cu/XLPE/CTS/LSOH/CWB/LSOH
6/10 (12) kV
65
Description Unit Details
Number and nominal cross-section No. × mm 2/mm 2 1 × 150/25 1 × 185/25 1 × 240/25 1 × 300/25
of the conductors
Construction data
Number and nominal cross-section No. × mm 2/mm 2 1 × 150/25 1 × 185/25 1 × 240/25 1 × 300/25
of the conductors
Approximate weight
of complete cable kg/km 2.,510 2,960 3,650 4,320
66 Delivery data
Length per drum ± 5% m 1.80 × 1.07 2.00 × 1.09 2.00 × 1.09 2.20 × 1.49
Diameter and max. width m×m 1.60 × 1.06 1.60 × 1.06 1.60 × 1.06 1.60 × 1.06
of wooden drum, type 18 20 20 22A
Approximate weight of heaviest reel
including cable kg 2,820 3,400 4,060 5,000
Mechanical data
Electrical data
Ampacity, in free air, ambient temperature 45 oC, acc. to IEC 60092-352 Table A.4
CONSTRUCTION 67
Conductors: Round, stranded and compacted bare copper class
2 acc. to IEC 60228
Insulation: •• Extruded semi‑conductive conductor screen
•• Insulation XLPE, dry cured
•• Extruded semi‑conductive insulation screen,
fully bonded
Screen: •• Semi‑conductive tape
•• Metallic screen, double bare copper tape
Inner covering: Halogen-free compound
Separator: Separating tape – optional
Armour (overall screen): Bare copper braid
Separator: Separating tape – optional
Outer sheath: Halogen-free compound type SHF 1
Colour of sheath: Red
CHARACTERISTIC
Maximum conductor operating +90 oC
temperature:
Maximum short-circuit +250 oC
conductor temperature:
Lowest ambient temperature -40 oC
for fixed installation:
Lowest installation 0 oC
temperature:
Minimum bending radius: 15 × D;
D – overall diameter of cable
NHKOXSek
Cu/XLPE/CTS/LSOH/CWB/LSOH
8.7/15 (17.5) kV
Fire performance
Flame retardant: IEC 60332-3-22 Category A
Smoke emission: IEC 61034-2
Corrosive gas emission: IEC 60754-1: < 0.5% HCl and HBr
Applications
Used for fixed installations on board of ships laying in air, but not on open decks
Mechanical data
Electrical data
Maximum D.C. phase conductor Ω/km 0.524 0.387 0.268 0.193 0.153
resistance at 20 oC
Maximum A.C. phase conductor Ω/km 0.668 0.496 0.345 0.249 0.198
resistance at 90 oC
Short circuit currents
70 Vertical flat formation and spaced A 175 214 277 338 395
Number and nominal cross-section No. × mm 2/mm 2 1 × 150/25 1 × 185/25 1 × 240/25 1 × 300/25
of the conductors
Construction data
71
Delivery data
Mechanical data
Electrical data
Ampacity, in free air, ambient temperature 45 oC, acc. to IEC 60092-352 Table A.4
All the information contained in this document – including tables and diagrams – is given in good faith and believed to be correct at the
time of publication. The information does not constitute a warranty nor representation for which TELE-FONIKA Kable assumes legal
responsibility. TELE-FONIKA Kable reserves rights to introduce changes to the document at any time.
MV three-core halogen-free
shipboard power cables
NHKOXSek
Cu/XLPE/CTS/LSOH/CWB/LSOH
6/10 (12) kV
IEC 60092-354
74 CONSTRUCTION
Conductors: Round, stranded and compacted bare copper class
2 acc. to IEC 60228
Insulation: •• Extruded semi‑conductive conductor screen
•• Insulation XLPE, dry cured
•• Extruded semi‑conductive insulation screen,
fully bonded
Screen: •• Semi‑conductive tape
•• Metallic screen, double bare copper tapes
over each core
Forming: Assembly of cores with central filler
Inner covering: Halogen-free compound
Separator: Separating tape – optional
Armour (overall screen): Bare copper braid
Separator: Separating tape – optional
Outer sheath: Halogen-free compound type SHF 1
Colour of sheath: Red
CHARACTERISTIC
Maximum conductor operating +90 oC
temperature:
Maximum short-circuit +250 oC
conductor temperature:
Lowest ambient temperature -40 oC
for fixed installation:
Lowest installation 0 oC
temperature:
Minimum bending radius: 15 × D;
D – overall diameter of cable
NHKOXSek
Cu/XLPE/CTS/LSOH/CWB/LSOH
6/10 (12) kV
Fire performance
Flame retardant: IEC 60332-3-22 Category A
Smoke emission: IEC 61034-2
Corrosive gas emission: IEC 60754-1: < 0.5% HCl and HBr
IEC 60754-2: pH ≥ 4.3; conductivity ≤ 10 µSmm -1
75
Applications
Used for fixed installations on board of ships laying in air, but not on open decks
76 Approximate thickness
of inner covering mm 1.4
Nominal dia. of wires
of bare copper braid mm 0.4
Number of wires in copper braid No. 36 × 8 36 × 9 36 × 9
Outer sheath thickness
•• Nominal mm 2.5 2.6 2.7
•• Minimum at a point mm 1.80 1.88 1.96
Approximate overall diameter
of complete cable (D) mm 46.4 49.2 52.5
Approximate weight
of complete cable kg/km 3,430 4,000 4,840
Delivery data
Mechanical data
Electrical data
78 Approximate weight
of complete cable kg/km 6,030 7,000 8,160
Delivery data
Mechanical data
Electrical data
CONSTRUCTION 79
Conductors: Round, stranded and compacted bare copper class
2 acc. to IEC 60228
Insulation: •• Extruded semi‑conductive conductor screen
•• Insulation XLPE, dry cured
•• Extruded semi‑conductive insulation screen,
fully bonded
Screen: •• Semi‑conductive tape
•• Metallic screen, double bare copper tapes
over each core
Forming: Assembly of cores with central filler
Inner covering: Halogen-free compound
Separator: Separating tape – optional
Armour (overall screen): Bare copper braid
Separator: Separating tape – optional
Outer sheath: Halogen-free compound type SHF 1
Colour of sheath: Red
CHARACTERISTIC
Maximum conductor operating +90 oC
temperature:
Maximum short-circuit +250 oC
conductor temperature:
Lowest ambient temperature -40 oC
for fixed installation:
Lowest installation 0 oC
temperature:
Minimum bending radius: 15 × D;
D – overall diameter of cable
NHKOXSek
Cu/XLPE/CTS/LSOH/CWB/LSOH
8.7/15 (17.5) kV
Fire performance
Flame retardant: IEC 60332-3-22 Category A
Smoke emission: IEC 61034-2
Corrosive gas emission: IEC 60754-1: < 0.5% HCl and HBr
Applications
Used for fixed installations on board of ships laying in air, but not on open decks
Mechanical data
Electrical data
CONSTRUCTION
84 Conductors Annealed stranded bare copper Class 2 in accordance IEC 60228
Conductor shield Semi‑conductive tape layer between the conductor and insulation
Insulation Ethylene-propylene rubber type E 90 to 3.22 UL 1309
Insulation shield Semi‑conductive layer + bare copper tape
Inner covering Polyolefin
Armouring Bare copper braid
Jacket: Polyolefin thermosetting compound, halogen-free
Colour of jacket Red
CHARACTERISTIC
Maximum conductor 90 oC
temperature:
Temperature range: -15 oC to +50 oC
Fire performance
Flame retardant: IEC 60332-3-22 Category A
Smoke emission: IEC 61034-2
Corrosive gas emission: IEC 60754-1
IEC 60754-2
Applications
•• For fixed installations on board of ships at all levels and open decks
•• Cables are halogen-free, non corrosive and low toxic gases
•• Other industrial applications
Type MVEPRHXCuHX
Marine Cables 6/10 (12) kV
Approvals
ABS
Details related to particular Approvals are informative only. Please contact manufacturer
to confirm whether the required cross-sections are covered by the Certificate.
Size Stranding Conductor Thickness Thickness Thickness Diameter Thickness Thickness Thickness
diameter of semi of insulation of semi-con over ins. of inner of screen Cu of outer
‑con. tape + Cu over and screens covering wires covering
+layer over insulation
conductor
mm2 mm mm mm mm mm mm mm mm
3 × 25 7 × 2.13 6.10 0.2 + 0.7 3.4 0.8 + 0.127 16.70 1.4 0.4 2.4
3 × 35 7 × 2.55 7.15 0.2 + 0.7 3.4 0.8 + 0.127 17.70 1.4 0.4 2.5
3 × 50 19 × 1.84 8.25 0.2 + 0.7 3.4 0.8 + 0.127 19.00 1.4 0.4 2.6
3 × 70 19 × 2.17 9.8 0.2 + 0.7 3.4 0.8 + 0.127 20.40 1.4 0.4 2.7
3 × 95 19 × 2.55 11.75 0.2 + 0.7 3.4 0.8 + 0.127 22.30 1.6 0.4 2.9
3 × 120 19 × 2.96 13.15 0.2 + 0.7 3.4 0.8 + 0.127 23.70 1.6 0.4 3.1
3 × 150 37 × 2.25 14.80 0.2 + 0.7 3.4 0.8 + 0.127 25.40 1.6 0.4 3.2
CONSTRUCTION
86 Conductors Annealed stranded bare copper Class 2 in accordance IEC 60228
Conductor shield Semi‑conductive tape layer between the conductor and insulation
Insulation Ethylene-propylene rubber type E 90 to 3.22 UL 1309
Insulation shield Semi‑conductive layer + bare copper tape
Inner covering Polyolefin
Armouring Bare copper braid
Jacket: Polyolefin thermosetting compound, halogen-free
Colour of jacket Red
CHARACTERISTIC
Maximum conductor temperature: 90 oC
Fire performance
Flame retardant: IEC 60332-3-22 Category A
Smoke emission: IEC 61034-2
Corrosive gas emission: IEC 60754-1
IEC 60754-2
Applications
•• For fixed installations on board of ships at all levels and open decks
•• Cables are halogen-free, non corrosive and low toxic gases
•• Other industrial applications
Type MVEPRHXCuHX
Marine Cables 8.7/15 (17.5) kV
Approvals
ABS
Details related to particular Approvals are informative only. Please contact manufacturer
to confirm whether the required cross-sections are covered by the Certificate.
mm 2
Minimum Approx. Maximum kg/km
mm mm mm
3 × 25 47.5 49.1 52.0 3,905
3 × 35 49.5 50.3 54.5 4,438
3 × 50 52.0 52.8 57.0 5,108
3 × 70 56.0 56.2 61.5 6,175
3 × 95 59.5 63.8 65.5 7,325
3 × 120 63.5 67.3 69.5 8,505
3 × 150 66.5 71.1 73.5 9,744
3 × 185 69.5 74.4 78.0 11,150
3 × 240 79.0 83.5 87.5 13,936
Size Stranding Conductor Thickness of Thickness Thickness Diameter Thickness Thickness Thickness
diameter semi‑con. tape of insulation of semi-con over ins. of inner of screen Cu of outer
+layer over + Cu over and screens covering wires covering
conductor insulation
mm2 mm mm mm mm mm mm mm mm
3 × 25 7 × 2.13 6.10 0.2 + 0.7 4.5 0.8 + 0.127 40.60 1.4 0.4 2.6
3 × 35 7 × 2.55 7.15 0.2 + 0.7 4.5 0.8 + 0.127 42.90 1.4 0.4 2.7
3 × 50 19 × 1.84 8.25 0.2 + 0.7 4.5 0.8 + 0.127 45.70 1.6 0.4 2.8
3 × 70 19 × 2.17 9.8 0.2 + 0.7 4.5 0.8 + 0.127 50.20 1.6 0.4 3.0
3 × 95 19 × 2.55 11.75 0.2 + 0.7 4.5 0.8 + 0.127 52.80 1.6 0.4 3.1
3 × 120 19 × 2.96 13.15 0.2 + 0.7 4.5 0.8 + 0.127 55.90 1.6 0.4 3.3
3 × 150 37 × 2.25 14.80 0.2 + 0.7 4.5 0.8 + 0.127 59.40 1.6 0.4 3.4
3 × 185 37 × 2.55 16.30 0.2 + 0.7 4.5 0.8 + 0.127 62.00 1.8 0.4 3.5
3 × 240 61 × 2.25 18.50 0.2 + 0.7 4.5 0.8 + 0.127 70.40 1.8 0.4 3.8
All the information contained in this document – including tables and diagrams – is given in good faith and believed to be correct at the
time of publication. The information does not constitute a warranty nor representation for which TELE-FONIKA Kable assumes legal
responsibility. TELE-FONIKA Kable reserves rights to introduce changes to the document at any time.
Shipboard instrumentation,
control and telecommunication
cables
FLAMEBLOCKER NTKOXSekw
150/250 V (300 V)
Cu/XLPE/CWB/LSOH
IEC 60092-376
CHARACTERISTIC
Inductance: Max. 0.67 mH/km
Pair capacitance: Max. 70 nF/km
Impedance at f=1MHz: 110±15 Ω
Maximum conductor operating temperature: +90 oC
Lowest ambient temperature for fixed -40 oC
installation:
FLAMEBLOCKER NTKOXSekw
150/250 V (300 V)
Cu/XLPE/CWB/LSOH
Fire performance 91
Flame retardant: IEC 60332-1-2; IEC 60332-3-22 Category A
Smoke emission: IEC 61034-2 min. 60%
Gases evolved during IEC 60754-1: < 0.5% HCl and HBr
combustion: IEC 60754-2: pH ≥ 4.3; conductivity ≤ 10 μSmm -1
Applications
Cables designed for connections of all sorts of measuring and telecommunication equipment including
emergency communications systems which proper functioning is necessary in order to ensure safety on ships.
Approvals
DNV-GL, LR, PRS, BV, RINA
Details related to particular Approvals are informative only. Please contact manufacturer to confirm whether
the required cross-sections are covered by the Certificate.
Number and cross- Number Nominal Thickness Diameter Nominal Overall diameter Net weight
sectional area of wires in thickness of tape of wires thickness of cables
of conductor conductor of in braid of sheath Min. Nom. Max.
cl. 2 insulation
n × mm 2 n mm mm mm mm mm mm mm kg/km
1 × 2 × 0.5 7 0.4 0.1 0.20 1.0 6.4 7.0 7.8 73
2 × 2 × 0.5* 7 0.4 0.1 0.20 1.0 7.0 7.8 8.6 96
FLAMEBLOCKER NTKOXSekw
150/250 V (300 V)
Cu/XLPE/CWB/LSOH
Number and cross- Number Nominal Thickness Diameter Nominal Overall diameter Net weight
sectional area of wires in thickness of tape of wires thickness of cables
of conductor conductor of in braid of sheath Min. Nom. Max.
cl. 2 insulation
Number and cross- Number Nominal Thickness Diameter Nominal Overall diameter Net weight
sectional area of wires in thickness of tape of wires thickness of cables
of conductor conductor of in braid of sheath Min. Nom. Max.
cl. 2 insulation
Number and cross- Number Nominal Thickness Diameter Nominal Overall diameter Net weight
sectional area of wires in thickness of tape of wires thickness of cables
of conductor conductor of in braid of sheath Min. Nom. Max.
cl. 2 insulation
Number and cross- Number Nominal Thickness Diameter Nominal Overall diameter Net weight
sectional area of of wires in thickness of inner of wires thickness of cables
Min. Nom. Max.
conductor conductor of bedding in braid of sheath
cl. 2 insulation
n × mm 2 n mm mm mm mm mm mm mm kg/km
2 × 0.75 7 0.5 0.1 0.20 1.0 7.2 7.8 8.8 90
3 × 0.75 7 0.5 0.1 0.20 1.0 7.5 8.1 9.2 101
4 × 0.75 7 0.5 0.1 0.20 1.0 8.0 8.7 9.8 119
5 × 0.75 7 0.5 0.1 0.20 1.1 8.8 9.5 11.0 136
7 × 0.75 7 0.5 0.1 0.20 1.1 9.4 10.2 11.5 164
10 × 0.75 7 0.5 0.1 0.20 1.2 11.5 12.6 14.0 225
12 × 0.75 7 0.5 0.1 0.20 1.2 12.0 12.9 14.5 246
14 × 0.75 7 0.5 0.1 0.20 1.2 12.5 13.5 15.0 268
16 × 0.75 7 0.5 0.1 0.20 1.2 13.0 14.1 15.5 299
FLAMEBLOCKER NTKOXSekw
150/250 V (300 V)
Cu/XLPE/CWB/LSOH
Number and cross- Number Nominal Thickness Diameter Nominal Overall diameter Net weight
sectional area of of wires in thickness of inner of wires thickness of cables
Min. Nom. Max.
conductor conductor of bedding in braid of sheath
cl. 2 insulation
Number Number Nominal Thickness Diameter Nominal Overall diameter Net weight
and cross- of wires in thickness of inner of wires thickness of cables
sectional area conductor of insulation bedding in braid of sheath Min. Nom. Max.
of conductor cl. 2
n × mm2 n mm mm mm mm mm mm mm kg/km
1 × 2 × 0.5 7 0.4 1.0 0.20 1.0 8.2 8.8 9.8 121
2 × 2 × 0.5* 7 0.4 1.0 0.20 1.1 9.2 9.7 11.0 144
3 × 2 × 0.5 7 0.4 1.0 0.20 1.1 11.0 11.7 13.0 188
4 × 2 × 0.5 7 0.4 1.0 0.20 1.2 11.5 12.7 14.0 223
7 × 2 × 0.5 7 0.4 1.0 0.20 1.2 13.0 14.4 16.0 291
10 × 2 × 0.5 7 0.4 1.0 0.30 1.4 16.5 18.2 19.5 444
12 × 2 × 0.5 7 0.4 1.0 0.30 1.4 17.0 18.7 20.0 477
14 × 2 × 0.5 7 0.4 1.0 0.30 1.4 17.5 19.4 21.0 513
19 × 2 × 0.5 7 0.4 1.0 0.30 1.5 19.5 21.4 23.0 626
24 × 2 × 0.5 7 0.4 1.0 0.30 1.6 22.5 24.5 26.0 756
37 × 2 × 0.5 7 0.4 1.0 0.30 1.7 25.0 27.7 29.5 982
1 × 3 × 0.5 7 0.4 1.0 0.20 1.1 8.6 9.2 10.5 133
3 × 3 × 0.5 7 0.4 1.0 0.20 1.2 12.0 12.9 14.0 235
7 × 3 × 0.5 7 0.4 1.0 0.30 1.3 15.0 16.4 18.0 403
12 × 3 × 0.5 7 0.4 1.0 0.30 1.4 18.5 20.5 22.0 592
1 × 2 × 0.75 7 0.5 1.0 0.20 1.1 9.4 9.7 11.0 144
2 × 2 × 0.75 7 0.5 1.0 0.20 1.1 10.0 10.7 12.0 175
3 × 2 × 0.75 7 0.5 1.0 0.20 1.2 12.5 13.3 15.0 239
4 × 2 × 0.75 7 0.5 1.0 0.20 1.2 13.5 14.3 16.0 276
FLAMEBLOCKER NTKOXSekw
150/250 V (300 V)
Cu/XLPE/CWB/LSOH
Number Number Nominal Thickness Diameter Nominal Overall diameter Net weight
and cross- of wires in thickness of inner of wires thickness of cables
sectional area conductor of insulation bedding in braid of sheath Min. Nom. Max.
of conductor cl. 2
96 5 × 2 × 0.75 7 0.5 1.0 0.23 1.3 15.0 15.9 18.0 365
7 × 2 × 0.75 7 0.5 1.0 0.30 1.3 16.0 17.0 19.0 413
10 × 2 × 0.75 7 0.5 1.0 0.30 1.5 19.5 21.0 23.5 570
12 × 2 × 0.75 7 0.5 1.0 0.30 1.5 20.0 21.6 24.0 617
14 × 2 × 0.75 7 0.5 1.0 0.30 1.5 21.0 22.5 25.0 685
19 × 2 × 0.75 7 0.5 1.0 0.30 1.6 23.0 24.8 27.5 844
20 × 2 × 0.75 7 0.5 1.0 0.30 1.6 24.5 26.0 28.5 875
24 × 2 × 0.75 7 0.5 1.0 0.30 1.7 27.0 28.6 31.5 1,025
37 × 2 × 0.75 7 0.5 1.0 0.30 1.9 30.5 32.6 36.0 1,350
1 × 3 × 0.75 7 0.5 1.0 0.20 1.1 9.6 10.1 11.5 160
3 × 3 × 0.75 7 0.5 1.0 0.30 1.3 14.0 15.1 17.0 346
7 × 3 × 0.75 7 0.5 1.0 0.30 1.4 17.5 18.8 21.0 524
12 × 3 × 0.75 7 0.5 1.0 0.30 1.6 22.5 23.9 26.5 785
1×2×1 7 0.5 1.0 0.20 1.1 9.4 10.1 11.5 162
2 × 2 × 1* 7 0.5 1.0 0.20 1.1 10.0 11.1 12.5 199
3×2×1 7 0.5 1.0 0.20 1.2 12.5 14.0 15.5 273
4×2×1 7 0.5 1.0 0.30 1.3 14.0 16.6 17.5 361
7×2×1 7 0.5 1.0 0.30 1.4 16.5 18.1 20.0 490
10 × 2 × 1 7 0.5 1.0 0.30 1.5 20.0 22.2 24.0 660
12 × 2 × 1 7 0.5 1.0 0.30 1.5 20.5 22.8 24.5 719
14 × 2 × 1 7 0.5 1.0 0.30 1.5 21.5 23.8 25.5 781
19 × 2 × 1 7 0.5 1.0 0.30 1.6 23.5 26.3 28.5 971
24 × 2 × 1 7 0.5 1.0 0.30 1.8 27.5 30.5 33.0 1,198
37 × 2 × 1 7 0.5 1.0 0.30 1.9 31.0 34.6 37.0 1,578
1×3×1 7 0.5 1.0 0.20 1.1 9.8 10.5 12.0 175
3×3×1 7 0.5 1.0 0.30 1.3 14.5 15.8 17.5 383
7×3×1 7 0.5 1.0 0.30 1.4 18.0 19.8 21.5 614
12 × 3 × 1 7 0.5 1.0 0.30 1.6 23.0 25.3 27.5 930
1 × 2 × 1.5 7 0.6 1.0 0.20 1.1 10.0 11.1 12.5 195
2 × 2 × 1.5* 7 0.6 1.0 0.20 1.2 11.5 12.5 14.0 253
3 × 2 × 1.5 7 0.6 1.0 0.30 1.3 15.0 16.3 18.0 384
FLAMEBLOCKER NTKOXSekw
150/250 V (300 V)
Cu/XLPE/CWB/LSOH
Number Number Nominal Thickness Diameter Nominal Overall diameter Net weight
and cross- of wires in thickness of inner of wires thickness of cables
sectional area conductor of insulation bedding in braid of sheath Min. Nom. Max.
of conductor cl. 2
CHARACTERISTIC
Maximum conductor operating +90 oC
temperature:
Lowest ambient temperature -40 oC
for fixed installation:
Lowest installation -15 oC
temperature:
Maximum short-circuit +250 oC
conductor temperature:
Minimum bending radius: 6×D
D – overall diameter of the cable
FLAMEBLOCKER NTKOXSekwf
150/250 V (300 V)
Cu/XLPE/LSOH
Fire performance
Flame retardant: IEC 60332-1-2; IEC 60332-3-22 Category A
Smoke emission: IEC 61034-2 min. 60%
Gases evolved during IEC 60754-1: < 0.5% HCl and HBr
combustion: IEC 60754-2: pH ≥ 4.3; conductivity ≤ 10 μSmm -1
99
Applications
Cables designed for connections of all sorts of measuring and telecommunication equipment
including emergency communications systems which proper functioning is necessary in order
to ensure safety on ships.
Approvals
DNV-GL
Details related to particular Approvals are informative only. Please contact manufacturer to confirm
whether the required cross-sections are covered by the Certificate.
Number and cross- Nominal Thickness Nominal Overall diameter Maximum Net weight
sectional area thickness of tape thickness of conductor of cables
of conductor of sheath Min. Nom. Max. resistance at
insulation temperature
20 oC
n × mm 2 mm mm mm mm mm mm kg/km Ω/km
1 × 2 × 0.5 0.4 0.1 1.0 5.4 6.2 6.6 45 40.4
2 × 2 × 0.5* 0.4 0.1 1.0 6.0 7.0 7.4 63 40.4
4 × 2 × 0.5 0.4 0.1 1.1 8.6 10.0 10.5 110 40.4
7 × 2 × 0.5 0.4 0.1 1.1 10.0 11.7 12.5 159 40.4
10 × 2 × 0.5 0.4 0.1 1.2 13.0 14.8 15.5 224 40.4
12 × 2 × 0.5 0.4 0.1 1.2 13.5 15.3 16.0 253 40.4
FLAMEBLOCKER NTKOXSekwf
150/250 V (300 V)
Cu/XLPE/LSOH
Number and cross- Nominal Thickness Nominal Overall diameter Maximum Net weight
sectional area thickness of tape thickness of conductor of cables
of conductor of sheath Min. Nom. Max. resistance at
insulation temperature
Number and cross- Nominal Thickness Nominal Overall diameter Maximum Net weight
sectional area thickness of tape thickness of conductor of cables
of conductor of sheath Min. Nom. Max. resistance at
insulation temperature
CONSTRUCTION
Conductors: Circular stranded bare or tinned copper class 2 or class
5 acc. to IEC 60228
Insulation: Cross-linked polyethylene XLPE 90 oC acc. to IEC
60092-351
Individual screen: Aluminium/polyester tape with the metallic side in
contact with tinned copper drain wire
Inner covering: Tape or extruded inner bedding (optional)
Armour (screen): Bare copper wire braid with the metallic contact
with a tinned copper drain wire
Colour code: Pair identification: Core a: blue (or black)
Core b: white
CHARACTERISTIC
Inductance: Max. 0.67 mH/km
Pair capacitance: Max. 100 nF/km
Impedance at f=1MHz: 80±15 Ω
FLAMEBLOCKER NTKOXSekf/ekw
150/250 V (300 V)
Cu/XLPE/IAM/CAM/CWB/LSOH
103
Minimum bending radius: 6×D
D – overall diameter of the cable
Fire performance
Flame retardant: IEC 60332-1-2; IEC 60332-3-22 Category A
Gases evolved during IEC 60754-1: < 0.5% HCl and HBr
combustion: IEC 60754-2: pH ≥ 4.3; conductivity ≤ 10 μSmm -1
Applications
Cables designed for measuring and control circuits on ships. For fixed installation only.
Approvals
DNV-GL, ABS, LR, PRS, RINA
Details related to particular Approvals are informative only. Please contact manufacturer to confirm
whether the required cross-sections are covered by the Certificate.
Number Number Nominal Thickness Diameter Nominal Overall diameter Net weight
and cross- of wires in thickness of tape of wires thickness of cables
sectional area conductor of insulation in braid of sheath
of conductor cl. 2
104
Min. Nom. Max.
n × mm 2 n mm mm mm mm mm mm mm kg/km
1 × 2 × 0.5 7 0.5 0.1 0.20 1.00 6.4 7.4 7.8 79
2 × 2 × 0.5 7 0.5 0.1 0.20 1.10 9.0 10.8 11.0 135
3 × 2 × 0.5 7 0.5 0.1 0.20 1.20 9.6 11.6 11.5 167
4 × 2 × 0.5 7 0.5 0.1 0.20 1.10 10.0 12.3 12.5 193
5 × 2 × 0.5 7 0.5 0.1 0.20 1.10 11.0 13.3 13.5 217
7 × 2 × 0.5 7 0.5 0.1 0.20 1.20 12.0 14.6 14.5 275
10 × 2 × 0.5 7 0.5 0.1 0.30 1.30 15.5 18.8 18.5 424
12 × 2 × 0.5 7 0.5 0.1 0.30 1.30 16.0 19.4 19.0 482
14 × 2 × 0.5 7 0.5 0.1 0.30 1.40 17.0 20.5 20.0 535
16 × 2 × 0.5 7 0.5 0.1 0.30 1.40 17.5 21.5 21.0 580
17 × 2 × 0.5 7 0.5 0.1 0.30 1.40 18.5 22.6 22.0 623
19 × 2 × 0.5 7 0.5 0.1 0.30 1.40 18.5 22.6 22.0 660
24 × 2 × 0.5 7 0.5 0.1 0.30 1.50 21.5 26.4 25.5 818
37 × 2 × 0.5 7 0.5 0.1 0.30 1.70 24.5 30.4 29.0 1,141
1 × 3 × 0.5 7 0.5 0.1 0.20 1.00 6.6 7.7 8.0 93
2 × 3 × 0.5 7 0.5 0.1 0.20 1.10 9.8 11.8 12.0 159
3 × 3 × 0.5 7 0.5 0.1 0.20 1.20 10.5 12.6 12.5 201
4 × 3 × 0.5 7 0.5 0.1 0.20 1.20 11.0 13.7 13.5 240
5 × 3 × 0.5 7 0.5 0.1 0.20 1.20 12.0 14.8 14.5 273
7 × 3 × 0.5 7 0.5 0.1 0.20 1.20 13.0 16.1 16.0 338
10 × 3 × 0.5 7 0.5 0.1 0.30 1.40 17.0 21.0 20.5 531
12 × 3 × 0.5 7 0.5 0.1 0.30 1.40 17.5 21.6 21.0 586
14 × 3 × 0.5 7 0.5 0.1 0.30 1.40 18.5 22.7 22.0 661
16 × 3 × 0.5 7 0.5 0.1 0.30 1.50 19.5 24.0 23.5 732
17 × 3 × 0.5 7 0.5 0.1 0.30 1.50 20.5 25.3 24.5 793
19 × 3 × 0.5 7 0.5 0.1 0.30 1.50 20.5 25.3 24.5 843
24 × 3 × 0.5 7 0.5 0.1 0.30 1.60 24.0 29.6 28.5 1,041
37 × 3 × 0.5 7 0.5 0.1 0.30 1.80 27.5 34.0 32.5 1,461
1 × 2 × 0.75 7 0.6 0.1 0.20 1.00 7.2 8.2 8.8 97
2 × 2 × 0.75 7 0.6 0.1 0.20 1.10 10.5 12.2 13.0 172
FLAMEBLOCKER NTKOXSekf/ekw
150/250 V (300 V)
Cu/XLPE/IAM/CAM/CWB/LSOH
Number Number Nominal Thickness Diameter Nominal Overall diameter Net weight
and cross- of wires in thickness of tape of wires thickness of cables
sectional area conductor of insulation in braid of sheath
of conductor cl. 2
105
Min. Nom. Max.
Number Number Nominal Thickness Diameter Nominal Overall diameter Net weight
and cross- of wires in thickness of tape of wires thickness of cables
sectional area conductor of insulation in braid of sheath
of conductor cl. 2
106
Min. Nom. Max.
Number and Number Nominal Nominal Diameter Nominal Overall diameter Net weight
cross-sectional of wires in thickness thickness of wires thickness of cables
area of conductor of insulation of inner in braid of outer Approximate
conductor cl. 2 sheath sheath
n × mm 2 n mm mm mm mm mm kg/km
1 × 2 × 0.5 7 0.5 1.0 0.20 1.00 9.1 123
2 × 2 × 0.5 7 0.5 1.0 0.20 1.10 12.5 206
4 × 2 × 0.5 7 0.5 1.0 0.20 1.20 14.2 271
7 × 2 × 0.5 7 0.5 1.0 0.30 1.30 16.9 404
10 × 2 × 0.5 7 0.5 1.0 0.30 1.40 20.7 551
14 × 2 × 0.5 7 0.5 1.0 0.30 1.40 22.2 659
19 × 2 × 0.5 7 0.5 1.0 0.30 1.50 24.5 815
27 × 2 × 0.5 7 0.5 1.0 0.30 1.60 28.9 1,059
37 × 2 × 0.5 7 0.5 1.0 0.30 1.70 32.1 1,327
1 × 3 × 0.5 7 0.5 1.0 0.20 1.10 9.6 138
2 × 3 × 0.5 7 0.5 1.0 0.20 1.20 13.7 244
4 × 3 × 0.5 7 0.5 1.0 0.20 1.20 15.4 319
7 × 3 × 0.5 7 0.5 1.0 0.30 1.30 18.4 485
10 × 3 × 0.5 7 0.5 1.0 0.30 1.50 22.9 670
14 × 3 × 0.5 7 0.5 1.0 0.30 1.50 24.6 817
19 × 3 × 0.5 7 0.5 1.0 0.30 1.60 27.2 987
FLAMEBLOCKER NTKOXSekf/ekw
150/250 V (300 V)
Cu/XLPE/IAM/CAM/CWB/LSOH
Number and Number Nominal Nominal Diameter Nominal Overall diameter Net weight
cross-sectional of wires in thickness thickness of wires thickness of cables
area of conductor of insulation of inner in braid of outer Approximate
conductor cl. 2 sheath sheath
Number and Number Nominal Nominal Diameter Nominal Overall diameter Net weight
cross-sectional of wires in thickness thickness of wires thickness of cables
area of conductor of insulation of inner in braid of outer Approximate
conductor cl. 2 sheath sheath
Number and Number Nominal Nominal Diameter Nominal Overall diameter Net weight
cross-sectional of wires in thickness thickness of wires thickness of cables
area of conductor of insulation of inner in braid of outer Approximate
conductor cl. 2 sheath sheath
Number and Maximum Nominal Nominal Diameter Nominal Overall Net weight
cross‑sectional diameter thickness thickness of wires thickness diameter of cables
area of wires in of insulation of inner in braid of outer Approximate
of conductor conductor cl. 5 sheath sheath
n × mm 2 mm mm mm mm mm mm kg/km
1 × 2 × 0.5 0.21 0.5 1.0 0.20 1.00 9.2 123
2 × 2 × 0.5 0.21 0.5 1.0 0.20 1.10 12.5 205
4 × 2 × 0.5 0.21 0.5 1.0 0.20 1.20 14.2 269
7 × 2 × 0.5 0.21 0.5 1.0 0.30 1.30 17.0 400
10 × 2 × 0.5 0.21 0.5 1.0 0.30 1.40 20.8 545
14 × 2 × 0.5 0.21 0.5 1.0 0.30 1.40 22.3 650
19 × 2 × 0.5 0.21 0.5 1.0 0.30 1.50 24.6 803
27 × 2 × 0.5 0.21 0.5 1.0 0.30 1.60 29.0 1,042
37 × 2 × 0.5 0.21 0.5 1.0 0.30 1.70 32.2 1,304
1 × 3 × 0.5 0.21 0.5 1.0 0.20 1.10 9.7 137
2 × 3 × 0.5 0.21 0.5 1.0 0.20 1.20 13.7 242
4 × 3 × 0.5 0.21 0.5 1.0 0.20 1.20 15.4 315
7 × 3 × 0.5 0.21 0.5 1.0 0.30 1.30 18.5 478
10 × 3 × 0.5 0.21 0.5 1.0 0.30 1.50 23.0 660
14 × 3 × 0.5 0.21 0.5 1.0 0.30 1.50 24.6 803
19 × 3 × 0.5 0.21 0.5 1.0 0.30 1.60 27.3 968
27 × 3 × 0.5 0.21 0.5 1.0 0.30 1.70 32.2 1,295
37 × 3 × 0.5 0.21 0.5 1.0 0.30 1.90 36.1 1,646
1 × 2 × 0.75 0.21 0.6 1.0 0.20 1.10 10.1 149
2 × 2 × 0.75 0.21 0.6 1.0 0.20 1.20 14.1 255
4 × 2 × 0.75 0.21 0.6 1.0 0.30 1.30 16.6 376
FLAMEBLOCKER NTKOXSekf/ekw
150/250 V (300 V)
Cu/XLPE/IAM/CAM/CWB/LSOH
Number and Maximum Nominal Nominal Diameter Nominal Overall Net weight
cross‑sectional diameter thickness thickness of wires thickness diameter of cables
area of wires in of insulation of inner in braid of outer Approximate
of conductor conductor cl. 5 sheath sheath
110 7 × 2 × 0.75
10 × 2 × 0.75
0.21
0.21
0.6
0.6
1.0
1.0
0.30
0.30
1.40
1.50
19.3
23.8
508
690
14 × 2 × 0.75 0.21 0.6 1.0 0.30 1.60 25.7 851
19 × 2 × 0.75 0.21 0.6 1.0 0.30 1.70 28.5 1,052
27 × 2 × 0.75 0.21 0.6 1.0 0.30 1.80 33.6 1,371
37 × 2 × 0.75 0.21 0.6 1.0 0.30 1.90 37.5 1,723
1 × 3 × 0.75 0.21 0.6 1.0 0.20 1.10 10.5 163
2 × 3 × 0.75 0.21 0.6 1.0 0.30 1.30 15.9 339
4 × 3 × 0.75 0.21 0.6 1.0 0.30 1.30 18.0 448
7 × 3 × 0.75 0.21 0.6 1.0 0.30 1.40 21.0 614
10 × 3 × 0.75 0.21 0.6 1.0 0.30 1.60 26.3 854
14 × 3 × 0.75 0.21 0.6 1.0 0.30 1.70 28.5 1,059
19 × 3 × 0.75 0.21 0.6 1.0 0.30 1.70 31.4 1,274
27 × 3 × 0.75 0.21 0.6 1.0 0.30 1.90 37.5 1,726
37 × 3 × 0.75 0.21 0.6 1.2 0.40 2.10 42.9 2,380
1×2×1 0.21 0.6 1.0 0.20 1.10 10.3 160
2×2×1 0.21 0.6 1.0 0.20 1.20 14.4 274
4×2×1 0.21 0.6 1.0 0.30 1.30 17.0 409
7×2×1 0.21 0.6 1.0 0.30 1.40 19.8 580
8×2×1 0.21 0.6 1.0 0.30 1.50 22.0 647
10 × 2 × 1 0.21 0.6 1.0 0.30 1.50 24.4 793
12 × 2 × 1 0.21 0.6 1.0 0.30 1.60 25.3 876
14 × 2 × 1 0.21 0.6 1.0 0.30 1.60 26.5 954
16 × 2 × 1 0.21 0.6 1.0 0.30 1.60 27.7 1,036
19 × 2 × 1 0.21 0.6 1.0 0.30 1.70 29.3 1,190
24 × 2 × 1 0.21 0.6 1.0 0.30 1.80 34.0 1,461
27 × 2 × 1 0.21 0.6 1.0 0.30 1.90 34.8 1,581
37 × 2 × 1 0.21 0.6 1.2 0.30 2.00 39.2 2,040
1×3×1 0.21 0.6 1.0 0.20 1.10 10.7 176
2×3×1 0.21 0.6 1.0 0.30 1.30 16.3 364
4×3×1 0.21 0.6 1.0 0.30 1.30 18.4 490
7×3×1 0.21 0.6 1.0 0.30 1.40 21.6 684
FLAMEBLOCKER NTKOXSekf/ekw
150/250 V (300 V)
Cu/XLPE/IAM/CAM/CWB/LSOH
Number and Maximum Nominal Nominal Diameter Nominal Overall Net weight
cross‑sectional diameter thickness thickness of wires thickness diameter of cables
area of wires in of insulation of inner in braid of outer Approximate
of conductor conductor cl. 5 sheath sheath
10 × 3 × 1
14 × 3 × 1
0.21
0.21
0.6
0.6
1.0
1.0
0.30
0.30
1.60
1.70
27.1
29.3
955
1,195
111
19 × 3 × 1 0.21 0.6 1.0 0.30 1.80 32.5 1,498
27 × 3 × 1 0.21 0.6 1.2 0.30 2.00 39.2 2,037
37 × 3 × 1 0.21 0.6 1.2 0.40 2.20 44.3 2,750
1 × 2 × 1.5 0.21 0.7 1.0 0.20 1.10 11.3 187
2 × 2 × 1.5 0.21 0.7 1.0 0.30 1.30 16.9 376
4 × 2 × 1.5 0.21 0.7 1.0 0.30 1.40 19.4 510
7 × 2 × 1.5 0.21 0.7 1.0 0.30 1.50 22.7 724
10 × 2 × 1.5 0.21 0.7 1.0 0.30 1.70 28.5 1,012
14 × 2 × 1.5 0.21 0.7 1.0 0.30 1.80 30.9 1,226
19 × 2 × 1.5 0.21 0.7 1.0 0.30 1.90 34.2 1,530
27 × 2 × 1.5 0.21 0.7 1.2 0.40 2.10 41.7 2,193
37 × 2 × 1.5 0.21 0.7 1.2 0.40 2.30 46.6 2,793
1 × 3 × 1.5 0.21 0.7 1.0 0.20 1.10 11.8 209
2 × 3 × 1.5 0.21 0.7 1.0 0.30 1.40 18.6 453
4 × 3 × 1.5 0.21 0.7 1.0 0.30 1.40 21.1 617
7 × 3 × 1.5 0.21 0.7 1.0 0.30 1.60 25.1 909
10 × 3 × 1.5 0.21 0.7 1.0 0.30 1.80 31.6 1,239
14 × 3 × 1.5 0.21 0.7 1.0 0.30 1.90 34.3 1,555
19 × 3 × 1.5 0.21 0.7 1.2 0.30 2.00 38.5 1,990
27 × 3 × 1.5 0.21 0.7 1.2 0.40 2.30 46.6 2,823
37 × 3 × 1.5 0.21 0.7 1.4 0.40 2.50 52.6 3,673
FLAMEBLOCKER NTKOXSekf/ekwf
150/250 V (300 V)
Cu/XLPE/IAM/CAM/LSOH
IEC 60092-376
CHARACTERISTIC
Maximum conductor operating +90 oC
temperature:
Lowest ambient temperature -40 oC
for fixed installation:
Lowest installation -15 oC
temperature:
Maximum short-circuit +250 oC
conductor temperature:
Minimum bending radius: 6×D
D – overall diameter of the cable
FLAMEBLOCKER NTKOXSekf/ekwf
150/250 V (300 V)
Cu/XLPE/IAM/CAM/LSOH
Fire performance
Flame retardant: IEC 60332-1-2; IEC 60332-3-22 Category A
Gases evolved during combustion: IEC 60754-1: < 0.5% HCl and HBr
IEC 60754-2: pH ≥ 4.3; conductivity ≤ 10 μSmm -1
113
Applications
Cables designed for measuring and control circuits on ships. For fixed installation only.
Approvals
DNV-GL
Details related to particular Approvals are informative only. Please contact manufacturer to confirm
whether the required cross-sections are covered by the Certificate.
Number and cross- Nominal Thickness Nominal Overall diameter Net weight Maximum conductor
sectional area thickness of tape thickness of of cables resistance at
of conductor of insulation sheath Min. Nom. Max. temperature 20 oC
n × mm 2
mm mm mm mm mm mm kg/km Ω/km
2 × 2 × 0.5 0.4 0.1 1.0 7.8 9.4 9.6 84 40.4
4 × 2 × 0.5 0.4 0.1 1.1 9.2 11.1 11.5 133 40.4
7 × 2 × 0.5 0.4 0.1 1.1 10.5 13.0 13.0 198 40.4
10 × 2 × 0.5 0.4 0.1 1.3 14.0 16.9 17.0 288 40.4
12 × 2 × 0.5 0.4 0.1 1.3 14.5 17.4 17.5 328 40.4
14 × 2 × 0.5 0.4 0.1 1.3 15.0 18.3 18.0 369 40.4
19 × 2 × 0.5 0.4 0.1 1.4 17.0 20.5 20.5 482 40.4
24 × 2 × 0.5 0.4 0.1 1.5 20.0 24.1 24.0 609 40.4
37 × 2 × 0.5 0.4 0.1 1.6 23.0 27.7 27.5 881 40.4
2 × 2 × 0.75 0.5 0.1 1.1 9.6 11.1 12.0 115 26.0
FLAMEBLOCKER NTKOXSekf/ekwf
150/250 V (300 V)
Cu/XLPE/IAM/CAM/LSOH
Number and cross- Nominal Thickness Nominal Overall diameter Net weight Maximum conductor
sectional area thickness of tape thickness of of cables resistance at
of conductor of insulation sheath Min. Nom. Max. temperature 20 oC
4 × 2 × 0.75 0.5 0.1 1.1 11.0 12.8 13.5 176 26.0
7 × 2 × 0.75 0.5 0.1 1.2 13.0 15.4 16.0 275 26.0
114 8 × 2 × 0.75
10 × 2 × 0.75
0.5
0.5
0.1
0.1
1.3
1.4
15.0
17.5
17.5
20.0
18.5
21.0
321
398
26.0
26.0
12 × 2 × 0.75 0.5 0.1 1.4 18.0 20.6 21.5 455 26.0
14 × 2 × 0.75 0.5 0.1 1.4 18.5 21.7 22.5 514 26.0
19 × 2 × 0.75 0.5 0.1 1.5 21.0 24.3 25.0 673 26.0
20 × 2 × 0.75 0.5 0.1 1.6 22.5 25.9 27.0 722 26.0
24 × 2 × 0.75 0.5 0.1 1.7 25.0 28.9 30.0 863 26.0
37 × 2 × 0.75 0.5 0.1 1.8 29.0 33.2 34.5 1,251 26.0
2×2×1 0.5 0.1 1.10 9.8 11.7 12.0 137 19.2
3×2×1 0.5 0.1 1.10 10.0 12.4 13.0 174 19.2
4×2×1 0.5 0.1 1.20 11.5 13.8 14.0 222 19.2
7×2×1 0.5 0.1 1.20 13.5 16.4 17.0 340 19.2
8×2×1 0.5 0.1 1.30 15.5 18.6 19.0 395 19.2
10 × 2 × 1 0.5 0.1 1.40 17.5 21.3 21.5 490 19.2
12 × 2 × 1 0.5 0.1 1.40 18.0 22.0 22.5 563 19.2
14 × 2 × 1 0.5 0.1 1.50 19.5 23.3 23.5 651 19.2
19 × 2 × 1 0.5 0.1 1.50 21.5 25.9 26.0 841 19.2
20 × 2 × 1 0.5 0.1 1.60 23.0 27.6 28.0 899 19.2
24 × 2 × 1 0.5 0.1 1.70 25.5 30.8 31.0 1,075 19.2
37 × 2 × 1 0.5 0.1 1.80 29.5 35.5 35.5 1,573 19.2
2 × 2 × 1.5 0.6 0.1 1.2 11.5 13.6 14.0 175 12.8
3 × 2 × 1.5 0.6 0.1 1.2 12.5 14.5 15.0 226 12.8
4 × 2 × 1.5 0.6 0.1 1.2 13.5 15.8 16.5 280 12.8
7 × 2 × 1.5 0.6 0.1 1.4 16.5 19.3 20.0 453 12.8
8 × 2 × 1.5 0.6 0.1 1.4 18.5 21.7 22.5 516 12.8
10 × 2 × 1.5 0.6 0.1 1.5 21.5 24.8 25.5 641 12.8
12 × 2 × 1.5 0.6 0.1 1.6 22.0 25.9 26.5 750 12.8
14 × 2 × 1.5 0.6 0.1 1.6 23.5 27.2 28.0 852 12.8
19 × 2 × 1.5 0.6 0.1 1.7 25.0 28.9 29.5 1,119 12.8
20 × 2 × 1.5 0.6 0.1 1.8 26.0 30.5 31.5 1,195 12.8
24 × 2 × 1.5 0.6 0.1 1.9 28.0 32.5 33.0 1,427 12.8
37 × 2 × 1.5 0.6 0.1 2.1 31.0 36.2 37.0 2,108 12.8
CHARACTERISTIC
Inductance: Max. 0.67 mH/km
Pair capacitance: Max. 70 nF/km
Impedance at f=1MHz: 110±15 Ω
Maximum conductor operating temperature: +90 oC
Lowest ambient temperature for fixed -40 oC
installation:
Lowest installation temperature: -15 oC
Minimum bending radius: 6×D
D – overall diameter of the cable
FLAME-X 950 NTKOGsekw
150/250 V (300 V)
Cu/SiR/CWB/LSOH
Fire performance
Fire resistant: IEC 60331-21: for cable diameters ≤ 20 mm
IEC 60331-1: for cable diameters > 20 mm
Flame retardant: IEC 60332-1-2; IEC 60332-3-22 Category A
Applications
Cables designed for connections of all sorts of measuring and telecommunication equipment
including emergency communications systems which proper functioning is necessary in order
to ensure safety on ships.
Approvals
DNV-GL, ABS, LR, PRS, BV, RINA
Details related to particular Approvals are informative only. Please contact manufacturer to confirm
whether the required cross-sections are covered by the Certificate.
Number and Number Nominal Thickness Diameter Nominal Overall diameter Net weight
cross-sectional of wires in thickness of tape of wires thickness of cables
area conductor of in braid of sheath Min. Nom. Max.
of conductor cl. 2 insulation
n × mm 2 n mm mm mm mm mm mm mm kg/km
1 × 2 × 0.5 7 0.6 0.1 0.20 1.0 7.0 8.0 8.6 90
2 × 2 × 0.5 * 7 0.6 0.1 0.20 1.0 8.0 9.0 9.6 119
3 × 2 × 0.5 7 0.6 0.1 0.20 1.1 10.0 11.7 12.5 167
4 × 2 × 0.5 7 0.6 0.1 0.20 1.2 11.0 12.9 13.5 205
7 × 2 × 0.5 7 0.6 0.1 0.20 1.2 13.0 15.1 15.5 288
FLAME-X 950 NTKOGsekw
150/250 V (300 V)
Cu/SiR/CWB/LSOH
Number and Number Nominal Thickness Diameter Nominal Overall diameter Net weight
cross-sectional of wires in thickness of tape of wires thickness of cables
area conductor of in braid of sheath Min. Nom. Max.
of conductor cl. 2 insulation
117
10 × 2 × 0.5 7 0.6 0.1 0.30 1.4 17.5 19.7 20.5 458
12 × 2 × 0.5 7 0.6 0.1 0.30 1.4 18.0 20.3 21.0 498
14 × 2 × 0.5 7 0.6 0.1 0.30 1.4 18.5 21.3 22.0 541
19 × 2 × 0.5 7 0.6 0.1 0.30 1.5 20.5 23.7 24.5 676
24 × 2 × 0.5 7 0.6 0.1 0.30 1.6 24.0 27.7 28.0 836
37 × 2 × 0.5 7 0.6 0.1 0.30 1.8 28.0 31.9 32.5 1,158
1 × 2 × 0.75 7 0.6 0.1 0.20 1.0 7.6 8.4 9.2 98
2 × 2 × 0.75 * 7 0.6 0.1 0.20 1.1 8.6 9.6 10.5 138
3 × 2 × 0.75 7 0.6 0.1 0.20 1.2 11.0 12.6 13.5 201
4 × 2 × 0.75 7 0.6 0.1 0.20 1.2 12.0 13.7 15.0 239
7 × 2 × 0.75 7 0.6 0.1 0.20 1.3 15.0 16.7 18.0 377
10 × 2 × 0.75 7 0.6 0.1 0.20 1.4 19.0 21.0 22.5 520
12 × 2 × 0.75 7 0.6 0.1 0.30 1.5 19.5 21.9 23.5 582
14 × 2 × 0.75 7 0.6 0.1 0.30 1.5 20.5 22.9 24.5 654
19 × 2 × 0.75 7 0.6 0.1 0.30 1.6 23.0 25.5 27.0 828
20 × 2 × 0.75 7 0.6 0.1 0.30 1.6 24.0 26.8 28.5 863
24 × 2 × 0.75 7 0.6 0.1 0.30 1.7 26.5 29.8 31.5 1,019
37 × 2 × 0.75 7 0.6 0.1 0.30 1.9 31.0 34.3 36.0 1,417
1 × 2 × 0.75 7 0.6 0.1 0.20 1.0 7.6 8.4 9.2 98
2 × 2 × 0.75 * 7 0.6 0.1 0.20 1.1 8.6 9.6 10.5 138
3 × 2 × 0.75 7 0.6 0.1 0.20 1.2 11.0 12.6 13.5 201
4 × 2 × 0.75 7 0.6 0.1 0.20 1.2 12.0 13.7 15.0 239
7 × 2 × 0.75 7 0.6 0.1 0.20 1.3 15.0 16.7 18.0 377
10 × 2 × 0.75 7 0.6 0.1 0.20 1.4 19.0 21.0 22.5 520
12 × 2 × 0.75 7 0.6 0.1 0.30 1.5 19.5 21.9 23.5 582
14 × 2 × 0.75 7 0.6 0.1 0.30 1.5 20.5 22.9 24.5 654
19 × 2 × 0.75 7 0.6 0.1 0.30 1.6 23.0 25.5 27.0 828
20 × 2 × 0.75 7 0.6 0.1 0.30 1.6 24.0 26.8 28.5 863
24 × 2 × 0.75 7 0.6 0.1 0.30 1.7 26.5 29.8 31.5 1,019
37 × 2 × 0.75 7 0.6 0.1 0.30 1.9 31.0 34.3 36.0 1,417
1 × 3 × 0.75 7 0.6 0.1 0.20 1.0 8.0 8.8 9.6 117
1 × 4 × 0.75 7 0.6 0.1 0.20 1.1 8.6 9.6 10.5 138
FLAME-X 950 NTKOGsekw
150/250 V (300 V)
Cu/SiR/CWB/LSOH
Number and Number Nominal Thickness Diameter Nominal Overall diameter Net weight
cross-sectional of wires in thickness of tape of wires thickness of cables
area conductor of in braid of sheath Min. Nom. Max.
of conductor cl. 2 insulation
118
1×2×1 7 0.6 0.1 0.20 1.0 7.6 8.7 9.4 113
2 × 2 × 1* 7 0.6 0.1 0.20 1.1 8.8 10.1 11.0 159
3×2×1 7 0.6 0.1 0.20 1.2 11.5 13.3 14.0 224
4×2×1 7 0.6 0.1 0.20 1.2 12.5 14.4 15.5 268
7×2×1 7 0.6 0.1 0.30 1.3 15.0 17.6 18.5 442
10 × 2 × 1 7 0.6 0.1 0.30 1.5 19.5 22.4 23.5 616
12 × 2 × 1 7 0.6 0.1 0.30 1.5 20.0 23.1 24.0 680
14 × 2 × 1 7 0.6 0.1 0.30 1.5 21.0 24.2 25.0 747
19 × 2 × 1 7 0.6 0.1 0.30 1.6 23.5 27.0 28.0 951
20 × 2 × 1 7 0.6 0.1 0.30 1.7 24.5 28.6 29.5 1,032
24 × 2 × 1 7 0.6 0.1 0.30 1.8 27.5 31.7 33.0 1,190
37 × 2 × 1 7 0.6 0.1 0.3 1.9 31.5 36.3 37.5 1,679
1×3×1 7 0.6 0.1 0.20 1.0 8.0 9.2 9.8 129
1×4×1 7 0.6 0.1 0.20 1.1 8.8 10.1 11.0 159
1 × 2 × 1.5 7 0.7 0.1 0.20 1.1 8.8 9.9 11.0 141
2 × 2 × 1.5 * 7 0.7 0.1 0.20 1.1 10.0 11.2 12.0 197
3 × 2 × 1.5 7 0.7 0.1 0.30 1.3 14.0 15.6 16.5 334
4 × 2 × 1.5 7 0.7 0.1 0.30 1.3 15.0 17.0 18.0 385
7 × 2 × 1.5 7 0.7 0.1 0.30 1.4 18.0 20.2 21.5 576
8 × 2 × 1.5 7 0.7 0.1 0.30 1.5 20.0 22.7 24.0 664
10 × 2 × 1.5 7 0.7 0.1 0.30 1.6 22.5 25.8 27.0 809
12 × 2 × 1.5 7 0.7 0.1 0.30 1.6 23.5 26.6 28.0 900
14 × 2 × 1.5 7 0.7 0.1 0.30 1.7 25.0 28.1 29.5 1,008
19 × 2 × 1.5 7 0.7 0.1 0.30 1.8 27.5 31.3 32.5 1,286
20 × 2 × 1.5 7 0.7 0.1 0.30 1.8 29.0 33.0 34.5 1,371
24 × 2 × 1.5 7 0.7 0.1 0.30 2.0 32.5 36.9 38.5 1,633
37 × 2 × 1.5 7 0.7 0.1 0.40 2.2 38.0 42.9 44.5 2,435
1 × 3 × 1.5 7 0.7 0.1 0.20 1.1 9.2 10.4 11.5 165
1 × 4 × 1.5 7 0.7 0.1 0.20 1.1 10.0 11.2 12.0 197
1 × 2 × 2.5 7 0.7 0.1 0.20 1.1 9.6 10.7 12.0 168
1 × 3 × 2.5 7 0.7 0.1 0.20 1.1 10.6 11.6 12.6 211
FLAME-X 950 NTKOGsekw
150/250 V (300 V)
Cu/SiR/CWB/LSOH
Number and Maximum Nominal Thickness Diameter Nominal Overall diameter Net weight
cross-sectional diameter thickness of tape of wires thickness of cables
Min. Nom. Max.
area of of wires in of insulation in braid of sheath
conductor conductor
n × mm 2
cl. 5
n mm mm mm mm mm mm mm kg/km
119
1 × 2 × 0.75 0.21 0.6 0.1 0.2 1.0 7.6 8.4 9.2 98
2 × 2 × 0.75 * 0.21 0.6 0.1 0.2 1.1 8.6 9.7 10.5 138
3 × 2 × 0.75 0.21 0.6 0.1 0.2 1.2 11.0 12.7 13.5 201
4 × 2 × 0.75 0.21 0.6 0.1 0.2 1.2 12.0 13.7 15.0 239
7 × 2 × 0.75 0.21 0.6 0.1 0.3 1.3 15.0 16.8 18.0 378
10 × 2 × 0.75 0.21 0.6 0.1 0.3 1.4 19.0 21.1 22.5 521
12 × 2 × 0.75 0.21 0.6 0.1 0.3 1.5 19.5 21.9 23.5 583
14 × 2 × 0.75 0.21 0.6 0.1 0.3 1.5 20.5 22.9 24.5 655
19 × 2 × 0.75 0.21 0.6 0.1 0.3 1.6 23.0 25.6 27.0 829
20 × 2 × 0.75 0.21 0.6 0.1 0.3 1.6 24.0 26.9 28.5 864
24 × 2 × 0.75 0.21 0.6 0.1 0.3 1.7 26.5 29.9 31.5 1,021
37 × 2 × 0.75 0.21 0.6 0.1 0.3 1.9 31.0 34.4 36.0 1,419
CHARACTERISTIC
Inductance: Max. 0.67 mH/km
Pair capacitance: Max. 70 nF/km
Impedance at f=1MHz: 110±15 Ω
Maximum conductor operating +90 oC
temperature:
Lowest ambient temperature -40 oC
for fixed installation:
Lowest installation -15 oC
temperature:
Minimum bending radius: 6×D
D – overall diameter of the cable
FLAME-X 950 NTKOGsekwf
150/250 V (300 V)
Cu/SiR/CAM/LSOH
Fire performance
Fire resistant: IEC 60331-21
Flame retardant: IEC 60332-1-2; IEC 60332-3-22 Category A
Applications
Cables designed for connections of all sorts of measuring and telecommunication equipment including
emergency communications systems which proper functioning is necessary in order to ensure safety
on ships.
n × mm 2 n mm mm mm mm mm mm kg/km
1 × 2 × 0.75 0.36 0.6 0.1 1.0 7.3 7.6 8.5 67
2 × 2 × 0.75 * 0.36 0.6 0.1 1.0 8.3 8.6 9.5 99
4 × 2 × 0.75 0.36 0.6 0.1 1.1 12.0 12.7 13.5 176
7 × 2 × 0.75 0.36 0.6 0.1 1.2 14.5 15.3 16.6 272
8 × 2 × 0.75 0.36 0.6 0.1 1.3 16.5 17.3 18.7 317
10 × 2 × 0.75 0.36 0.6 0.1 1.4 19.0 19.8 21.3 394
12 × 2 × 0.75 0.36 0.6 0.1 1.4 19.5 20.4 21.9 448
14 × 2 × 0.75 0.36 0.6 0.1 1.4 20.5 21.4 23.0 505
19 × 2 × 0.75 0.36 0.6 0.1 1.5 23.0 24.0 25.7 660
20 × 2 × 0.75 0.36 0.6 0.1 1.6 24.5 25.6 27.4 707
24 × 2 × 0.75 0.36 0.6 0.1 1.7 27.5 28.5 30.4 845
37 × 2 × 0.75 0.36 0.6 0.1 1.8 31.5 32.8 34.9 1,220
1 × 2 × 1.5 0.52 0.7 0.1 1.0 8.6 8.9 9.8 96
2 × 2 × 1.5 0.52 0.7 0.1 1.1 10.0 10.5 11.5 155
FLAME-X 950 NTKOGsekwf
150/250 V (300 V)
Cu/SiR/CAM/LSOH
122 7 × 2 × 1.5
8 × 2 × 1.5
0.52
0.52
0.7
0.7
0.1
0.1
1.4
1.4
18.4
20.5
19.0
21.3
20.5
22.7
450
515
10 × 2 × 1.5 0.52 0.7 0.1 1.5 23.5 24.3 26.0 640
12 × 2 × 1.5 0.52 0.7 0.1 1.6 24.5 25.4 27.2 745
14 × 2 × 1.5 0.52 0.7 0.1 1.6 25.5 26.7 28.5 850
19 × 2 × 1.5 0.52 0.7 0.1 1.7 29.0 29.9 31.9 1,105
20 × 2 × 1.5 0.52 0.7 0.1 1.8 30.5 31.8 33.9 1,182
24 × 2 × 1.5 0.52 0.7 0.1 1.9 34.0 35.5 37.8 1,410
37 × 2 × 1.5 0.52 0.7 0.1 2.1 39.5 41.1 43.7 2,078
All the information contained in this document – including tables and diagrams – is given in good faith and believed to be correct at the
time of publication. The information does not constitute a warranty nor representation for which TELE-FONIKA Kable assumes legal
responsibility. TELE-FONIKA Kable reserves rights to introduce changes to the document at any time.
Classification Type cables Classification Type cables
Bureau Bureau
FLAMEBLOCKER NKOXSekw
FLAMEBLOCKER NKOXSekw EMC
FLAMEBLOCKER NTKOXSekw
FLAMEBLOCKER NTKOXSekf/ekw
They are designed for operation on ships and drilling plat- 125
forms. They are characterised by excellent mechanical and
chemical resistance required to work in harsh conditions.
CONSTRUCTION
128 Conductors Tinned annealed circular stranded copper
class 2 acc. to BS EN 60228
Insulation Halogen-free elastomer compound EPR type GP4 acc. to
BS 7655-1.2
Outer sheath Halogen-free, heat-resistant, oil-resisting and flame-
retardant elastomer compound type SW4 acc. to BS
7655-2.6
Colour of outer sheath Green/yellow
Cable marking ELECTRIC CABLE Type SW4 “number of cores” “x”
“conductor size” “600/1,000 V” “TFK3” “BS6883” “UKOOA
code” “IEC60332-3-22 cat. A” “year” “metre mark”
CHARACTERISTIC
Maximum conductor operating +90 oC
temperature:
Lowest ambient temperature -40 oC
for fixed installation:
Lowest installation -15 oC
temperature:
Minimum bending radius: Overall diameter of cable (D) Minimum bending radius
≤ 10 mm 3D
16-25 mm 4D
> 25 mm 6D
D – overall diameter of cable
Fire performance
Flame retardant: IEC 60332-3-22 Category A
Smoke emission: BS EN 61034-2, IEC 61034-2
Corrosive gas emission: BS EN 50267-2-1, IEC 60754-1: type SW4 cables ≤ 0.5% HCl
6571 Earth SW4 0.6/1 kV
EPR/ZH
BS 6883
Applications
Unarmoured earth cable for fixed installations in all areas, including accommodation and open deck
in ships and offshore units.
Please refer to technical section for additional information relating to these cables.
657(*) SW4 0.6/1 kV
EPR/ZH
BS 6883
Flame retardant, halogen-free, offshore & shipboard power,
control & lighting cables with elastomeric insulation and sheath
CONSTRUCTION
130
Conductors Tinned annealed circular stranded copper
Class 5 acc. to BS EN 60228 Class 2 acc. to BS EN 60228
1)
For sizes: 1.0 � 1.5 mm 2 2)
For sizes 2.5 mm 2 and above
Insulation Halogen-free elastomer compound EPR type GP4 acc. to BS
7655-1.2
Core identification 3) All cores are white with black printed numbers
Outer sheath Heat-resistant, oil-resisting and flame-retardant elastomer
compound type SW4 acc. to BS 7655-2.6
Colour of outer Black
sheath
Cable marking ELECTRIC CABLE Type SW4 “number of cores” “x” “conductor
size” “600/1,000 V” “TFK3” “BS6883” “UKOOA code”
“IEC60332-3-22 cat. A” “year” “metre mark”
1)
Class 2 conductors for sizes below 2.5 mm 2 are available on request.
2)
Class 5 flexible conductors for sizes above 2.5 mm 2 are available on request.
3)
Coloured cores are available on request.
CHARACTERISTIC
Maximum conductor operating +90 oC
temperature:
Lowest ambient temperature -40 oC
for fixed installation:
Lowest installation -15 oC
temperature:
Minimum bending radius: Overall diameter of cable (D) Minimum bending radius
≤ 10 mm 3D
16-25 mm 4D
> 25 mm 6D
D – overall diameter of cable
657(*) SW4 0.6/1 kV
EPR/ZH
BS 6883
Fire performance
Flame retardant: IEC 60332-3-22 Category A
Smoke emission: BS EN 61034-2, IEC 61034-2
Corrosive gas emission: BS EN 50267-2-1, IEC 60754-1: type SW4 cables ≤ 0.5% HCl
UV resistant: UL 1581 131
Applications
Power, control or lighting cable for fixed installations in all areas and open deck in ships and offshore units.
Approvals
LR
Details related to particular Approvals are informative only. Please contact manufacturer to confirm whether
the required cross-sections are covered by the Certificate.
Number and Class of conductor Nominal Nominal Approximate Approximate net UKOOA Code
cross-sectional thickness of thickness of outer overall diameter weight of cables
area of conductor insulation sheath of cable SW4
n × mm 2 mm mm mm kg/km
1×1 5 0.8 1.0 4.8 34 WF101
1 × 1.5 5 0.8 1.0 5.1 40 WF102
1 × 2.5 2 0.8 1.0 5.6 54 WF103
1×4 2 1.0 1.0 6.7 78 WF104
1×6 2 1.0 1.0 7.3 101 WF106
1×6 5 1.0 1.0 7.1 96 –
1 × 10 2 1.0 1.0 8.2 144 WF110
1 × 16 2 1.0 1.1 9.5 216 WF116
1 × 25 2 1.2 1.2 11.5 328 WF125
1 × 35 2 1.2 1.2 12.6 429 WF135
657(*) SW4 0.6/1 kV
EPR/ZH
BS 6883
Number and Class of conductor Nominal Nominal Approximate Approximate net UKOOA Code
cross-sectional thickness of thickness of outer overall diameter weight of cables
area of conductor insulation sheath of cable SW4
Number and Class of conductor Nominal Nominal Approximate Approximate net UKOOA Code
cross-sectional thickness of thickness of outer overall diameter weight of cables
area of conductor insulation sheath of cable SW4
Number and Class of conductor Nominal Nominal Approximate Approximate net UKOOA Code
cross-sectional thickness of thickness of outer overall diameter weight of cables
area of conductor insulation sheath of cable SW4
* Based on standard
Please refer to technical section for additional information relating to these cables.
658(*) SW4 0.6/1 kV
TCu/EPR/ZH/GSWB/ZH
BS 6883
Halogen-free, flame retardant, offshore & shipboard power, control &
lighting cables with elastomeric insulation and sheath, with steel wire braid
CONSTRUCTION
Conductors Tinned annealed circular stranded copper
135
Class 5 acc. to BS EN 60228 Class 2 acc. to BS EN 60228
1)
For sizes: 1.0 & 1.5 mm 2 2)
For sizes 2.5 mm 2 and above
Insulation Halogen-free elastomer compound EPR type GP4 acc. to BS
7655-1.2
Core identification 3) All cores are white with black printed numbers
Inner sheath Halogen-free, heat-resistant, oil-resisting and flame-retardant
elastomer compound type SW4 acc. to BS 7655-2.6
Armour/Mechanical screen 4) Galvanized steel wire braid
Separator Separator, suitable tape between the braid and outer sheath
Outer sheath Halogen-free, heat-resistant, oil-resisting and flame-retardant
elastomer compound type SW4 acc. to BS 7655-2.6
Colour of outer sheath Black
Cable marking ELECTRIC CABLE Type SW4 “number of cores” “x” “conductor
size” “600/1,000 V” “TFK3” “BS6883” “UKOOA code”
“IEC60332-3-22 cat. A” “year” “metre mark”
1)
Class 2 conductors for sizes below 2.5 mm 2 are available on request.
2)
Class 5 flexible conductors for sizes above 2.5 mm 2 are available on request.
3)
Coloured cores are available on request.
4)
Tinned copper wire braid version is available on request.
CHARACTERISTIC
Maximum conductor operating temperature: +90 oC
Lowest ambient temperature for fixed installation: -40 oC
Lowest installation temperature: -15 oC
Minimum bending radius: Overall diameter Minimum bending
of cable (D) radius
< 25 mm 4D
> 25 mm 6D
D – overall diameter of cable
658(*) SW4 0.6/1 kV
TCu/EPR/ZH/GSWB/ZH
BS 6883
Fire performance
Flame retardant: IEC 60332-3-22 Category A
Smoke emission: BS EN 61034-2, IEC 61034-2
Corrosive gas emission: BS EN 50267-2-1, IEC 60754-1: type SW4 cables ≤ 0.5% HCl
Applications
Armoured power, control or lighting cable for fixed installations in all areas including accommodation
and open deck in ships and offshore units where halogen-free cable protection is required.
Approvals
LR
Details related to particular Approvals are informative only. Please contact manufacturer to confirm whether
the required cross-sections are covered by the Certificate.
Number Class of Nominal Nominal Diameter of Nominal Approximate Approximate UKOOA Code
and cross- conductor thickness of thickness of steel wires in thickness of overall net weight
sectional area insulation inner sheath braid outer sheath diameter of cables
of conductor of cable SW4
n × mm 2 mm mm mm mm mm kg/km
*2 × 0.75 5 0.8 1 0.3 1.2 11.3 198 –
2×1 5 0.8 1 0.3 1.2 11.6 200 WB201
2 × 1.5 5 0.8 1.1 0.3 1.2 12.4 241 WB202
2 × 2.5 2 0.8 1.1 0.3 1.2 13.4 283 WB203
2×4 2 1 1.2 0.3 1.3 15.6 387 WB204
2×6 2 1 1.2 0.3 1.4 16.9 476 WB206
2 × 10 2 1 1.3 0.3 1.4 19.2 627 WB210
2 × 16 2 1 1.4 0.3 1.5 22 853 WB216
658(*) SW4 0.6/1 kV
TCu/EPR/ZH/GSWB/ZH
BS 6883
Number Class of Nominal Nominal Diameter of Nominal Approximate Approximate UKOOA Code
and cross- conductor thickness of thickness of steel wires in thickness of overall net weight
sectional area insulation inner sheath braid outer sheath diameter of cables
of conductor of cable SW4
Number Class of Nominal Nominal Diameter of Nominal Approximate Approximate UKOOA Code
and cross- conductor thickness of thickness of steel wires in thickness of overall net weight
sectional area insulation inner sheath braid outer sheath diameter of cables
of conductor of cable SW4
Number Class of Nominal Nominal Diameter of Nominal Approximate Approximate UKOOA Code
and cross- conductor thickness of thickness of steel wires in thickness of overall net weight
sectional area insulation inner sheath braid outer sheath diameter of cables
of conductor of cable SW4
* Based on standard
4 40 34 28
6 52 44 36
10 72 61 50
140
16 96 82 67
25 127 108 89
35 157 133 110
50 196 167 137
70 242 206 169
95 293 249 205
120 339 288 237
150 389 331 272
185 444 377 311
240 522 444 365
300 601 511 421
Please refer to technical section for additional information relating to these cables.
658(*)(c) SW4 150/250 V
TCu/EPR/CAM/ZH/GSWB/ZH
BS 6883
Halogen-free, flame retardant, offshore & shipboard instrumentation
cables, elastomer insulated and sheathed, collectively
screened pairs, triples or quads with steel wire braid
CONSTRUCTION 141
Conductors Tinned annealed circular stranded copper class 5 1) acc. to BS
EN 60228
Insulation Halogen-free elastomer compound EPR type GP4 acc. to BS
7655-1.2
Pairs identification* Black and white with printed number of pairs in contrasting
colour on the insulation
Triples identification* Black, white and red with printed number of triples in
contrasting colour on the insulation
Quad identification* Black, white, red and blue with printed number of quad in
a contrasting colour on the insulation
Separator Polyester tape
Collective screen Aluminium/polyester tape with the metallic side in contact
with tinned copper drain wire
Inner sheath Halogen-free, heat-resistant, oil-resisting and flame-
retardant elastomer compound type SW4, acc. to BS
7655-2.6
Separator Polyester tape
Armour/mechanical screen Galvanized steel wire braid 2)
Outer sheath Halogen-free, heat-resistant, oil-resisting and flame-
retardant elastomer compound type SW4, acc. to BS
7655-2.6
Colour of outer sheath Grey (Non Intrinsically Safe) or blue (Intrinsically Safe) 3)
Cable marking ELECTRIC CABLE Type SW4 “number of pairs or triples,
quads” “x” “ conductor size” “(C)” “150/250 V” “TFK3”
“BS6883” “UKOOA code” “IEC60332-3-22 cat. A” “year”
“metre mark”
1)
Class 2 conductors are available on request
2)
Tinned copper wire braid version is available on request
3)
Black outer sheathing is available on request
CHARACTERISTIC
Maximum conductor operating temperature: +90 oC
Fire performance
Flame retardant: IEC 60332-3-22 Category A
Corrosive gas emission: BS EN 50267-2-1, IEC 60754-1: type SW4 cables ≤ 0.5% HCl
Applications
Armoured instrumentation cable for fixed installations in all areas including accommodation and on open deck
in ships and offshore units where halogen-free cable protection is required.
Approvals
LR
Details related to particular Approvals are informative only. Please contact manufacturer to confirm whether
the required cross-sections are covered by the Certificate.
Number of pairs Class of Nominal Nominal Diameter of Nominal Approximate Approximate UKOOA Code
and nominal area conductor thickness of thickness of steel wires thickness of overall diameter net weight of (Grey/Blue)
of conductor insulation inner sheath in braid outer sheath of cable cables
n × 2 × mm 2 mm mm mm mm mm kg/km
1 × 2 × 1.5 * 2 0.8 1.2 0.3 1.4 13.2 245 –
1 × 4 × 2.5 * 2 0.8 1.4 0.3 1.6 16.3 422 –
658(*)(c) SW4 150/250 V
TCu/EPR/CAM/ZH/GSWB/ZH
BS 6883
Number of pairs Class of Nominal Nominal Diameter of Nominal Approximate Approximate UKOOA Code
and nominal area conductor thickness of thickness of steel wires thickness of overall diameter net weight of (Grey/Blue)
of conductor insulation inner sheath in braid outer sheath of cable cables
2 × 2 × 0.75 * 5 0.8 1.2 0.3 1.4 13.3 340 –
2 × 2 × 1.0 * 5 0.8 1.2 0.3 1.4 13.5 357 –
143
2 × 2 × 1.5 * 5 0.8 1.4 0.3 1.6 15.1 352 –
2 × 2 × 2.5 * 2 0.8 1.4 0.3 1.6 16.6 404 –
2 × 2 × 2.5 * 5 0.8 1.4 0.3 1.6 16.6 404 –
3 × 2 × 0.75 5 0.8 1.2 0.3 1.4 16.9 435 KJH00/KGH00
3 × 2 × 1.0 5 0.8 1.2 0.3 1.4 17.8 483 KJH01/KGH01
3 × 2 × 1.5 * 5 0.8 1.4 0.3 1.6 18.9 497 KJH02/KGH02
4 × 2 × 1.5 * 5 0.8 1.4 0.3 1.6 20.4 561 –
5 × 2 × 0.75 * 5 0.8 1.4 0.3 1.5 19.8 563 –
5 × 2 × 1.0 * 5 0.8 1.4 0.3 1.6 20.4 613 –
5 × 2 × 1.5 * 5 0.8 1.4 0.3 1.6 21.9 716 –
5 × 2 × 2.5 * 2 0.8 1.5 0.3 1.7 24.6 846 –
6 × 2 × 1* 5 0.8 1.4 0.3 1.6 21.9 595 –
7 × 2 × 0.75 5 0.8 1.4 0.3 1.5 21.2 566 KJJ00/KGJ00
7 × 2 × 1.0 5 0.8 1.4 0.3 1.6 22.2 640 KJJ01/KGJ01
7 × 2 × 1.5 * 5 0.8 1.6 0.3 1.8 23.8 761 KJJ02/KGJ02
8 × 2 × 1.5 * 5 0.8 1.6 0.3 1.8 25.5 889 –
10 × 2 × 0.75 * 5 0.8 1.6 0.3 1.7 25.5 922 –
10 × 2 × 1.0 * 5 0.8 1.6 0.3 1.8 26.3 889 –
10 × 2 × 1.5 * 5 0.8 1.6 0.3 1.8 28.2 1,184 –
12 × 2 × 0.75 5 0.8 1.6 0.3 1.7 27.0 1,087 KJK00/KGJ00
12 × 2 × 1.0 5 0.8 1.6 0.3 1.8 28.3 1,155 KJK01/KGJ01
12 × 2 × 1.5 * 5 0.8 1.8 0.45 2.1 30.9 1,470 KJK02/KGJ02
16 × 2 × 1.5 * 5 0.8 1.8 0.45 2.1 34.2 1,540 –
20 × 2 × 0.75 5 0.8 1.8 0.45 2.0 33.4 1,549 KJL00/KGL00
20 × 2 × 1.0 5 0.8 1.8 0.45 2.1 35.7 1,810 KJL01/KGL01
20 × 2 × 1.5 * 5 0.8 2.0 0.45 2.2 37.6 2,061 KJL02/KGL02
20 × 2 × 1.5 * 2 0.8 2.0 0.45 2.2 38.2 1,919 –
24 × 2 × 1.5 * 5 0.8 2.0 0.45 2.2 40.3 2,102 –
27 × 2 × 0.75 5 0.8 1.9 0.45 2.2 37.7 1,724 –
27 × 2 × 1 5 0.8 2.0 0.45 2.2 39.9 1,993 –
27 × 2 × 1.5 * 5 0.8 2.1 0.45 2.3 42.4 2,503 –
37 × 2 × 0.75 5 0.8 2.1 0.45 2.3 43.0 2,199 –
37 × 2 × 1 5 0.8 2.2 0.45 2.4 44.5 2,454 –
658(*)(c) SW4 150/250 V
TCu/EPR/CAM/ZH/GSWB/ZH
BS 6883
Number of pairs Class of Nominal Nominal Diameter of Nominal Approximate Approximate UKOOA Code
and nominal area conductor thickness of thickness of steel wires thickness of overall diameter net weight of (Grey/Blue)
of conductor insulation inner sheath in braid outer sheath of cable cables
37 × 2 × 1.5 * 5 0.8 2.3 0.45 2.5 48.6 3,191 –
n × 3 × mm 2 mm mm mm mm mm kg/km
144
3 × 3 × 0.75 5 0.8 1.3 0.3 1.4 18.5 440 KJS00/KGS00
3 × 3 × 1.0 5 0.8 1.3 0.3 1.5 19.6 519 KJS01/KGS01
2 × 3 × 1.5 2 0.8 1.4 0.3 1.6 19.9 493 –
3 × 3 × 1.5 * 5 0.8 1.4 0.3 1.6 20.3 560 –
4 × 3 × 1.5 * 5 0.8 1.5 0.3 1.7 22.3 674 –
5 × 3 × 1* 2 0.8 1.5 0.3 1.7 22.5 700 –
7 × 3 × 0.75 5 0.8 1.4 0.3 1.6 24.2 745 KJT00/KGT00
7 × 3 × 1.0 5 0.8 1.5 0.3 1.7 25.7 871 KJT01/KGT01
7 × 3 × 1.5 * 5 0.8 1.7 0.3 1.9 27.4 1,008 –
8 × 3 × 1.5 * 5 0.8 1.7 0.45 2.0 29.8 1,229 –
12 × 3 × 0.75 5 0.8 1.7 0.45 1.9 30.4 1,381 KJU00/KGU00
12 × 3 × 1.0 5 0.8 1.7 0.45 2.0 32.2 1,591 KJU01/KGU01
12 × 3 × 1.5 * 5 0.8 1.9 0.45 2.1 34.4 1,772 –
16 × 3 × 1.5 * 5 0.8 2.0 0.45 2.2 38.5 2,044 –
n × 4 × mm 2
mm mm mm mm mm kg/km
3 × 4 × 0.75 * 5 0.8 1.4 0.3 1.5 20.6 531 –
3 × 4 × 1* 5 0.8 1.4 0.3 1.6 21.3 576 –
3 × 4 × 1.5 * 5 0.8 1.6 0.3 1.7 23.4 702 –
7 × 4 × 0.75 * 5 0.8 1.6 0.3 1.7 26.8 908 –
7 × 4 × 1* 5 0.8 1.6 0.45 1.8 28.2 1,223 –
7 × 4 × 1.5 * 5 0.8 1.7 0.45 1.9 30.8 1,466 –
* Based on standard
Electrical parameters
Nominal cross-sectional area Maximum conductor resistance at 20 oC (Ω/km)
Class 5 Class 2
0.75 mm 2
26.7 24.8
1.0 mm 2
20.0 18.2
Please refer to technical section for additional information relating to these cables.
658(*)(I) SW4 150/250 V
TCu/EPR/IAM/ZH/GSWB/ZH
BS 6883
Halogen-free, flame retardant, offshore & shipboard instrumentation
cables, elastomer insulated and sheathed, individually
screened pairs, triples or quads with steel wire braid
CONSTRUCTION 145
Conductors Tinned annealed circular stranded copper class 5 1)
acc. to BS EN 60228
Insulation Halogen-free elastomer compound EPR type GP4
acc. to BS 7655-1.2
Pairs identification * Black and white with printed number of pairs in
contrasting colour on the insulation
Triples identification * Black, white and red with printed number of triples in
contrasting colour on the insulation
Quads identification * Black, white, red and blue with printed number of quads in
contrasting colour on the insulation
Separator Polyester tape
Individual screen Aluminium/polyester tape with the metallic contact with
tinned copper drain wire
Separator Polyester tape
Inner sheath Halogen-free, heat-resistant, oil-resisting and flame-
retardant elastomer compound type SW4, acc. to BS
7655-2.6
Armour/mechanical screen Galvanized steel wire braid 2)
Outer sheath Halogen-free, heat-resistant, oil-resisting and flame-
retardant elastomer compound type SW4, acc. to BS
7655-2.6
Colour of outer sheath Grey (Non Intrinsically Safe) or blue (Intrinsically Safe) 3)
Cable marking ELECTRIC CABLE Type SW4 “number of pairs or triples,
quads” “x” “ conductor size” “(I)” “150/250 V” “TFK3”
“BS6883” “UKOOA code” “IEC60332-3-22 cat. A” “year”
“metre mark”
1)
Class 2 conductors are available on request
2)
Tinned copper wire braid version is available on request
3)
Black outer sheathing is available on request
CHARACTERISTIC
Maximum conductor operating +90 oC
temperature:
Lowest ambient temperature -40 oC
146
for fixed installation:
Lowest installation -15 oC
temperature:
Minimum bending radius: 8 × D;
D – overall diameter of cable
Fire performance
Flame retardant: IEC 60332-3-22 Category A
Smoke emission: BS EN 61034-2, IEC 61034-2
Corrosive gas emission: BS EN 50267-2-1, IEC 60754-1: type SW4 cables < 0.5% HCl
Applications
Armoured instrumentation cable for fixed installations in all areas including accommodation and on open deck
in ships and offshore units where halogen-free cable protection is required.
Approvals
LR
Details related to particular Approvals are informative only. Please contact manufacturer to confirm whether
the required cross-sections are covered by the Certificate.
Number of Class of Nominal Nominal Diameter of Nominal Approximate Approximate UKOOA Code
pairs and conductor thickness of thickness of steel wires in thickness of overall net weight (Grey/Blue)
nominal area insulation inner sheath braid outer sheath diameter of of cables
of conductor cable
n × 2 × mm 2 mm mm mm mm mm kg/km
1 × 2 × 0.75
1 × 2 × 1.0
5
5
0.8
0.8
1
1
0.3
0.3
1.2
1.2
11.5
11.7
197
205
KKF00/KHF00
KKF01/KHF01
147
1 × 2 × 1.5 * 5 0.8 1.2 0.3 1.4 13.1 252 KKF02/KHF02
1 × 2 × 1.5 * 2 0.8 1.2 0.3 1.4 13.2 257 –
1 × 2 × 2.5 * 2 0.8 1.3 0.3 1.4 14.3 301 KKF03/KHF03
2 × 2 × 0.75 * 5 0.8 1.2 0.3 1.4 13.1 260 –
2 × 2 × 1.5 * 5 0.8 1.3 0.3 1.5 14.5 344 –
3 × 2 × 0.75 5 0.8 1.2 0.3 1.4 17.1 398 KKH00/KHH00
3×2×1 5 0.8 1.3 0.3 1.4 17.8 447 KKH01/KHH01
3 × 2 × 1.5 * 5 0.8 1.3 0.3 1.5 18.3 448 KKH02/KHH02
4 × 2 × 0.75 5 0.8 1.4 0.3 1.6 18.5 453 –
4 × 2 × 1.5 * 5 0.8 1.4 0.3 1.6 20.2 552 –
5 × 2 × 1.5 * 5 0.8 1.4 0.3 1.6 21.7 673 –
7 × 2 × 0.75 5 0.8 1.4 0.3 1.6 21.8 658 KKJ00/KHJ00
7 × 2 × 1.0 5 0.8 1.4 0.3 1.6 22.9 739 KKJ01/KHJ01
7 × 2 × 1.5 * 5 0.8 1.4 0.3 1.6 23.2 786 KKJ02/KHJ02
10 × 2 × 1.5 * 5 0.8 1.7 0.45 1.9 29.1 1,248 –
10 × 2 × 2.5 * 2 0.8 1.7 0.45 1.9 32.2 1,605 –
12 × 2 × 0.75 5 0.8 1.6 0.3 1.8 26.5 944 KKK00/KHK00
12 × 2 × 1.0 5 0.8 1.7 0.45 1.9 28.9 1,200 KKK01/KHK01
12 × 2 × 1.5 * 5 0.8 1.7 0.45 1.9 30.2 1,341 KKK02/KHK02
12 × 2 × 2.5 * 5 0.8 1.9 0.45 2.1 34.2 1,696 –
Number of Class of Nominal Nominal Diameter of Nominal Approximate Approximate UKOOA Code
pairs and conductor thickness of thickness of steel wires in thickness of overall net weight (Grey/Blue)
nominal area insulation inner sheath braid outer sheath diameter of of cables
of conductor cable
148 n × 3 × mm mm mm mm mm mm kg/km
2
* Based on standard
Please refer to technical section for additional information relating to these cables.
659(*) SW4 0.6/1 kV
TCu/EPR/ZH/TPBWB/ZH
BS 6883
Halogen-free, flame retardant, offshore & shipboard power cables with
elastomeric insulation and sheath, with tinned phosphor bronze wire braid
CONSTRUCTION
Conductors Tinned annealed circular stranded copper class 2 acc.
149
to BS EN 60228
Insulation Halogen-free elastomer compound EPR type GP4 acc.
to BS 7655-1.2
Core identification Red or black
CHARACTERISTIC
Maximum conductor operating temperature: +90 oC
Lowest ambient temperature for fixed -40 oC
installation:
Lowest installation temperature: -15 oC
Minimum bending radius: Overall diameter Minimum
of cable (D) bending radius
< 25 mm 4D
> 25 mm 6D
D – overall diameter of cable
659(*) SW4 0.6/1 kV
TCu/EPR/ZH/TPBWB/ZH
BS 6883
Fire performance
Flame retardant: IEC 60332-3-22 Category A
Smoke emission: BS EN 61034-2, IEC 61034-2
Corrosive gas emission: BS EN 50267-2-1, IEC 60754-1: type SW4 cables ≤ 0.5% HCl
Applications
Armoured instrumentation cable for fixed installations in all areas including accommodation and on open deck
in ships and offshore units where halogen-free cable protection is required.
Number and Class of the Nominal Nominal Diameter of Nominal Approximate Approximate
cross-sectional conductor thickness of thickness of wires in braid thickness of overall net weight of
area of insulation inner sheath outer sheath diameter of the cable
conductor cable
n × mm 2 mm mm mm mm mm kg/km
1×1 2 0.8 1 0.3 1.1 8.5 137
1 × 1.5 2 0.8 1 0.3 1.1 8.8 145
1 × 2.5 2 0.8 1 0.3 1.1 9.2 160
1×4 2 1 1 0.3 1.1 10.2 190
1×6 2 1 1 0.3 1.1 10.8 219
1 × 10 2 1 1 0.3 1.2 11.9 280
1 × 16 2 1 1.1 0.3 1.2 13.3 371
1 × 25 2 1.2 1.2 0.3 1.3 15.4 519
1 × 35 2 1.2 1.2 0.3 1.4 16.8 644
1 × 50 2 1.4 1.3 0.3 1.4 18.5 789
1 × 50 * 5 1.4 1.3 0.3 1.4 18.7 798
1 × 70 2 1.4 1.3 0.3 1.5 20.4 1,029
1 × 95 2 1.6 1.4 0.3 1.6 23.2 1,372
1 × 120 2 1.6 1.5 0.3 1.7 25.1 1,635
1 × 150 2 1.8 1.6 0.3 1.8 27.4 1,975
659(*) SW4 0.6/1 kV
TCu/EPR/ZH/TPBWB/ZH
BS 6883
Number and Class of the Nominal Nominal Diameter of Nominal Approximate Approximate
cross-sectional conductor thickness of thickness of wires in braid thickness of overall net weight of
area of insulation inner sheath outer sheath diameter of the cable
conductor cable
*) Based on standard
Please refer to technical section for additional information relating to these cables.
TCu/MGT/EPR/IS/ZH/GSWB/ZH
150/250 V
BS 7917
Halogen-free, fire resistant, low smoke, instrumentation cables
with elastomeric insulation and sheath, with steel wire braid
CONSTRUCTION
152 Conductors Tinned annealed circular stranded copper according to BS EN
60228 class 2 or class 5
Insulation Mica glass tape
Halogen-free elastomer compound EPR type GP4 acc. to BS
7655-1.2
Pairs identification Black and white with printed number of pairs in contrasting colour
on the insulation
Triples identification Black, white and red with printed number of triples in contrasting
colour on the insulation
Quads identification Black, white, red and blue with printed number of quads in
contrasting colour on the insulation
Screen Individual screen
Aluminium/polyester tape with the metallic side in contact with
tinned copper drain wire
Inner sheath Halogen-free elastomer compound EPR type SB 1 acc. to BS 7917
Braid armour Galvanized steel wire braid
Separator Separator, suitable tape between the braid and outer sheath
Outer sheath Halogen-free, heat-resistant, oil-resisting and flame-retardant
elastomer compound type SW4 acc. to BS 7655-2.6
Colour of outer sheath Grey or other colors can be provided
Cable marking e.g. ELECTRIC CABLE “Type SW4 F1” “number of pairs or triples or
quads” “x” “conductor size” “(I)” “150/250 V” “TFK3” “BS 7917”
“UKOOA code” “IEC60331-21” “IEC60332-3-22 cat. A” “year”
“metre mark”
CHARACTERISTIC
Maximum conductor operating temperature: +90 oC
Maximum conductor temperature during short circuit: +250 oC
Lowest ambient temperature for fixed installation: -40 oC
Lowest installation temperature: -15 oC
Minimum bending radius: 6D
D – overall diameter of cable
TCu/MGT/EPR/IS/ZH/GSWB/ZH
150/250 V
BS 7917
Fire performance
Flame retardant: IEC 60332-3-22 Category A
Fire resistant: IEC 60331-21
Smoke emission: BS EN 61034-2, IEC 61034-2
Gases evolved during combustion: BS EN 50267-2-1, IEC 60754-1 type SW4 cables: ≤ 0.5% HCl 153
Applications
Elastomer insulated, fire resistant (limited circuit integrity) cables for fixed wiring in ships
and on mobile and fixed offshore units.
Approvals
LR
Details related to particular Approvals are informative only. Please contact manufacturer to confirm whether
the required cross-sections are covered by the Certificate.
Number of Class of Nominal Nominal Diameter of Nominal Approximate Approximate UKOOA Code
pairs and conductor thickness of thickness of steel wires in thickness of overall net weight of (Grey/Blue)
nominal area insulation inner sheath braid outer sheath diameter of cables
of conductor cable
n × 2 × mm 2 mm mm mm mm mm kg/km
1 × 2 × 0.75 5 0.8 1 0.3 1.2 12.9 221 GPF00/GMF00
1 × 2 × 1.0 5 0.8 1 0.3 1.2 13.1 225 GPF01/GMF01
1 × 2 × 1.5 * 5 0.8 1.2 0.3 1.4 14.6 279 GPF02/GMF02
1 × 2 × 1.5 * 2 0.8 1.2 0.3 1.4 14.6 279 –
1 × 2 × 2.5 * 2 0.8 1.3 0.3 1.4 15.7 332 GPF03/GMF03
2 × 2 × 0.75 * 5 0.8 1.2 0.3 1.4 14.9 312 –
2 × 2 × 1.0 * 5 0.8 1.2 0.3 1.4 15.1 324 –
2 × 2 × 1.5 * 2 0.8 1.3 0.3 1.5 16.4 386 –
2 × 2 × 1.5 * 5 0.8 1.3 0.3 1.5 16.3 404 –
TCu/MGT/EPR/IS/ZH/GSWB/ZH
150/250 V
BS 7917
Number of Class of Nominal Nominal Diameter of Nominal Approximate Approximate UKOOA Code
pairs and conductor thickness of thickness of steel wires in thickness of overall net weight of (Grey/Blue)
nominal area insulation inner sheath braid outer sheath diameter of cables
of conductor cable
3 × 2 × 0.75 5 0.8 1.2 0.3 1.4 19.1 433 GPH00/GMH00
3×2×1 5 0.8 1.3 0.3 1.4 19.6 453 GPH01/GMH01
154 3 × 2 × 1.5 * 5 0.8 1.3 0.3 1.5 21 522 GPH02/GMH02
3 × 2 × 2.5 * 5 0.8 1.4 0.3 1.5 23 692 GPH03/GMH03
7 × 2 × 0.75 5 0.8 1.4 0.3 1.6 24.9 740 GPJ00/GMJ00
7 × 2 × 1.0 5 0.8 1.4 0.3 1.6 25.3 759 GPJ01/GMJ01
7 × 2 × 1.5 * 5 0.8 1.4 0.3 1.6 26.9 866 GPJ02/GMJ02
12 × 2 × 0.75 5 0.8 1.6 0.3 1.8 31.3 1,129 GPK00/GMK00
12 × 2 × 1.0 5 0.8 1.7 0.45 1.9 32.9 1,296 GPK01/GMK01
12 × 2 × 1.5 * 5 0.8 1.7 0.45 1.9 35 1,475 GPK02/GMK02
20 × 2 × 0.75 5 0.8 1.9 0.45 2.1 39.8 1,925 GPL00/GML00
20 × 2 × 1.0 5 0.8 1.9 0.45 2.2 40.8 2,070 GPL01/GML01
20 × 2 × 1.5 * 5 0.8 2.0 0.45 2.3 43.9 2,444 GPL02/GML02
n × 3 × mm 2 mm mm mm mm mm kg/km
1 × 3 × 0.75 5 0.8 1 0.3 1.2 13.4 248 GPR00/GMR00
1 × 3 × 1.0 5 0.8 1.1 0.3 1.2 13.8 266 GPR01/GMR01
1 × 3 × 1.5 * 5 0.8 1.2 0.3 1.4 15.1 314 GPR02/GMR02
1 × 3 × 1.5 * 2 0.8 1.2 0.3 1.4 15.2 318 –
1 × 3 × 2.5 * 2 0.8 1.4 0.3 1.5 16.8 394 GPR03/GMR03
n × 4 × mm 2
mm mm mm mm mm kg/km
1 × 4 × 0.75 5 0.8 1.1 0.3 1.2 14.5 291 GPX00/GMX00
1 × 4 × 1.0 5 0.8 1.1 0.3 1.2 14.8 307 GPX01/GMX01
1 × 4 × 1.5 * 5 0.8 1.2 0.3 1.4 16.1 359 GPX02/GMX02
1 × 4 × 2.5 * 2 0.8 1.4 0.3 1.5 17.9 471 GPX03/GMX03
* Based on standard
Without approvals
Number of Class of Nominal Nominal Diameter of Nominal Approximate Approximate UKOOA Code
pairs and conductor thickness of thickness of steel wires in thickness of overall net weight of (Grey/Blue)
nominal area of insulation inner sheath braid outer sheath diameter of cables
conductor cable
n × 2 × mm 2 mm mm mm mm mm kg/km
TCu/MGT/EPR/IS/ZH/GSWB/ZH
150/250 V
BS 7917
Number of Class of Nominal Nominal Diameter of Nominal Approximate Approximate UKOOA Code
pairs and conductor thickness of thickness of steel wires in thickness of overall net weight of (Grey/Blue)
nominal area of insulation inner sheath braid outer sheath diameter of cables
conductor cable
155
5 × 2 × 0.75 * 2 0.8 1.4 0.3 1.6 23.3 641 –
5 × 2 × 1.5 * 2 0.8 1.4 0.3 1.6 25.5 761 –
10 × 2 × 0.75 * 2 0.8 1.6 0.3 1.8 30.2 1,054 –
24 × 2 × 1.5 * 5 0.8 2.1 0.45 2.4 47.7 2,793 –
27 × 2 × 0.75 5 0.8 2.0 0.45 2.3 45.3 2,445 –
27 × 2 × 1 5 0.8 2.1 0.45 2.4 47.6 2,646 –
27 × 2 × 1.5 * 5 0.8 2.2 0.45 2.5 50.1 3,120 –
n × 3 × mm 2
mm mm mm mm mm kg/km
3 × 3 × 0.75 5 0.8 1.3 0.3 1.5 21.0 552 –
3×3×1 5 0.8 1.3 0.3 1.5 21.4 583 –
3 × 3 × 1.5 * 5 0.8 1.5 0.3 1.7 23.5 688 –
7 × 3 × 0.75 5 0.8 1.5 0.3 1.7 28.3 1,007 –
7 × 3 × 1.0 5 0.8 1.5 0.3 1.7 28.9 1,073 GPT01/
GMT01
7 × 3 × 1.5 * 5 0.8 1.7 0.3 2.0 31.7 1,282 –
12 × 3 × 0.75 5 0.8 1.7 0.45 2.0 36.1 1,672 –
12 × 3 × 1.0 5 0.8 1.8 0.45 2.0 37.0 1,801 GPU01/
GMU01
12 × 3 × 1.5 * 5 0.8 1.9 0.45 2.1 39.8 2,083 –
n × 4 × mm 2
mm mm mm mm mm kg/km
3 × 4 × 0.75 5 0.8 1.4 0.3 1.5 24.0 670 –
3×4×1 5 0.8 1.4 0.3 1.6 24.6 727 –
3 × 4 × 1.5 * 5 0.8 1.6 0.3 1.7 26.7 854 –
7 × 4 × 0.75 5 0.8 1.6 0.3 1.7 31.6 1,229 –
7×4×1 5 0.8 1.6 0.45 1.8 33.0 1,450 –
7 × 4 × 1.5 * 5 0.8 1.7 0.45 1.9 35.6 1,644 –
* Based on standard
TCu/MGT/EPR/CS/ZH/GSWB/ZH
150/250 V
BS 7917
Halogen-free, fire resistant, low smoke, instrumentation cables
with elastomeric insulation and sheath, with steel wire braid
CONSTRUCTION
156 Conductors Tinned annealed circular stranded copper according to BS EN 60228
class 2 or class 5
Insulation Mica glass tape
Halogen-free elastomer compound EPR type GP4 acc. to BS
7655-1.2
Pairs identification Black and white with printed number of pairs in contrasting color on
the insulation
Screen Collective screen
Aluminium/polyester tape with the metallic side in contact with
tinned copper drain wire
Inner sheath Halogen-free elastomer compound EPR type SB 1 acc. to BS 7917
Braid armour Galvanized steel wire braid
Separator Separator, suitable tape between the braid and outer sheath
Outer sheath Halogen-free, heat-resistant, oil-resisting and flame-retardant
elastomer compound type SW4 acc. to BS 7655-2.6
Colour of outer sheath Grey or blue or other colors can be provided.
Cable marking ELECTRIC CABLE “Type SW4 F1” “number of pairs” “x” “conductor
e.g. size” “(C)” “150/250 V” “TFK3” “BS 7917” “UKOOA code” “IEC60331–
21” “IEC60332–3–22 cat. A” “year” “metre mark”
CHARACTERISTIC
Maximum conductor operating temperature: +90 oC
Maximum conductor temperature during short circuit: +250 oC
Lowest ambient temperature for fixed installation: -40 oC
Lowest installation temperature: -15 oC
Minimum bending radius: 6D
D – overall diameter of cable
TCu/MGT/EPR/CS/ZH/GSWB/ZH
150/250 V
BS 7917
Fire performance
Flame retardant: IEC 60332-3-22 Category A
Fire resistant: IEC 60331-21
Smoke emission: BS EN 61034-2, IEC 61034-2
Gases evolved during combustion: BS EN 50267-2-1, IEC 60754-1, 157
type SW4 cables: ≤ 0.5% HCl
Applications
Elastomer insulated, fire resistant (limited circuit integrity) cables for fixed wiring in ships and on mobile and fixed
offshore units.
Approvals
LR
Details related to particular Approvals are informative only. Please contact manufacturer to confirm whether
the required cross-sections are covered by the Certificate.
Number of Class of Nominal Nominal Diameter of Nominal Approximate Approximate UKOOA Code
pairs and conductor thickness of thickness of steel wires in thickness of overall net weight of (Grey/Blue)
nominal area insulation inner sheath braid outer sheath diameter of cables
of conductor cable
n × 2 × mm 2 mm mm mm mm mm kg/km
7 × 2 × 1.5 * 5 0.8 1.6 0.3 1.8 27.9 908 GNJ02/GLJ02
n × 2 × mm 2
mm mm mm mm mm kg/km
12 × 2 × 0.75 5 0.8 1.6 0.3 1.7 31.3 1,075 GNK00/GLK00
12 × 2 × 1.0 5 0.8 1.6 0.3 1.8 32.1 1,104 GNK01/GLK01
12 × 2 × 1.5 * 5 0.8 1.8 0.45 2.1 35.8 1,496 GNK02/GLK02
20 × 2 × 0.75 2 0.8 1.8 0.45 2 39.6 1,665 GNL00/GLL00
20 × 2 × 1.0 5 0.8 1.8 0.45 2.1 40.6 1,792 GNL01/GLL01
20 × 2 × 1.5 * 5 0.8 2 0.45 2.2 43.9 2,157 GNL02/GLL02
20 × 2 × 1.5 * 2 0.8 2 0.45 2.2 44.6 2,274 –
TCu/MGT/EPR/IS/ZH/GSWB/ZH
150/250 V
BS 7917
Number of Class of Nominal Nominal Diameter of Nominal Approximate Approximate UKOOA Code
pairs and conductor thickness of thickness of steel wires in thickness of overall net weight of (Grey/Blue)
nominal area insulation inner sheath braid outer sheath diameter of cables
of conductor cable
158
2 × 2 × 1.0 * 5 0.8 1.2 0.3 1.4 15.7 334 –
2 × 2 × 1.0 * 2 0.8 1.2 0.3 1.4 15.9 341 –
2 × 2 × 1.5 * 5 0.8 1.2 0.3 1.4 16.0 358 –
2 × 2 × 1.5 * 2 0.8 1.2 0.3 1.4 16.3 370 –
3 × 2 × 0.75 5 0.8 1.2 0.3 1.4 19.3 434 GNH00/GLH00
3 × 2 × 1.0 5 0.8 1.2 0.3 1.4 19.6 437 GNH01/GLH01
3 × 2 × 1.5 * 5 0.8 1.4 0.3 1.6 21.5 533 GNH02/GLH02
3 × 2 × 2.5 * 5 0.8 1.6 0.3 1.8 24.1 735 GNH03/GLH03
7 × 2 × 0.75 5 0.8 1.4 0.3 1.5 24.8 707 GNJ00/GLJ00
7 × 2 × 1.0 5 0.8 1.4 0.3 1.6 25.5 737 GNJ01/GLJ01
7 × 2 × 1.5 * 5 0.8 1.6 0.3 1.8 27.9 908 GNJ02/GLJ02
n × 2 × mm 2
mm mm mm mm mm kg/km
12 × 2 × 0.75 5 0.8 1.6 0.3 1.7 31.3 1,075 GNK00/GLK00
12 × 2 × 1.0 5 0.8 1.6 0.3 1.8 32.1 1,104 GNK01/GLK01
12 × 2 × 1.5 * 5 0.8 1.8 0.45 2.1 35.8 1,496 GNK02/GLK02
20 × 2 × 0.75 2 0.8 1.8 0.45 2 39.6 1,665 GNL00/GLL00
20 × 2 × 1.0 5 0.8 1.8 0.45 2.1 40.6 1,792 GNL01/GLL01
20 × 2 × 1.5 * 5 0.8 2 0.45 2.2 43.9 2,157 GNL02/GLL02
20 × 2 × 1.5 * 2 0.8 2 0.45 2.2 44.6 2,274 –
* Based on standard
Without approvals
Number of Class of Nominal Nominal Diameter of Nominal Approximate Approximate UKOOA
pairs and conductor thickness of thickness of steel wires in thickness of overall net weight of Code
nominal area of insulation inner sheath braid outer sheath diameter cables
conductor of cable
mm mm mm mm mm kg/km
1 × 2 × 1.5 * 2 0.8 1.2 0.3 1.4 14.8 282 –
2 × 2 × 2.5 * 2 0.8 1.2 0.3 1.4 17.4 425 –
7 × 4 × 1.5 * 5 0.8 1.7 0.45 1.9 35.7 1,601 –
TCu/MGT/EPR/IS/ZH/GSWB/ZH
150/250 V
BS 7917
* Based on standard
TCu/MGT/EPR/ZH/GSWB/ZH
0.6/1 kV SW4
BS 7917
Halogen-free, fire resistant, low smoke, low voltage cables
with elastomeric insulation and sheath, with steel wire braid
CONSTRUCTION
160 Conductors Tinned annealed circular stranded copper according
to BS EN 60228 class 2 or class 5
1)
Other colours available on request
CHARACTERISTIC
Maximum conductor operating temperature: +90 oC
Maximum conductor temperature during short circuit: +250 oC
Lowest ambient temperature for fixed installation: -40 oC
Lowest installation temperature: -15 oC
Minimum bending radius: Overall diameter Minimum bending
of cable (D) radius
< 25 mm 4D
> 25 mm 6D
D – overall diameter of cable
TCu/MGT/EPR/ZH/GSWB/ZH
0.6/1 kV SW4
BS 7917
Fire performance
Flame retardant: IEC 60332-3-22 Category A
Fire resistant: IEC 60331-21
Smoke emission: BS EN 61034-2, IEC 61034-2
Corrosive gas emission: BS EN 50267-2-1, IEC 60754-1: 161
type SW4 cables ≤ 0.5% HCl
Applications
Elastomer insulated, fire resistant (limited circuit integrity) cables for fixed wiring in ships and on mobile
and fixed offshore units.
Approvals
LR
Details related to particular Approvals are informative only. Please contact manufacturer to confirm whether
the required cross-sections are covered by the Certificate.
Number and Class of Nominal Nominal Diameter of Nominal Approximate Approximate UKOOA
cross-sectional conductor thickness of thickness of steel wires in thickness of overall diameter net weight of Code
area of conductor insulation inner sheath braid outer sheath of cable cables SW4
n × mm 2 mm mm mm mm mm kg/km
2 × 1.5 5 0.8 1.1 0.3 1.2 14.4 312 YD202
2 × 2.5 2 0.8 1.1 0.3 1.2 15.3 350 YD203
2×4 2 1 1.2 0.3 1.3 17.5 464 YD204
2×6 2 1 1.2 0.3 1.4 18.9 542 YD206
2 × 10 2 1 1.3 0.3 1.4 20.9 696 YD210
2 × 16 2 1 1.4 0.3 1.5 23.7 947 YD216
2 × 25 2 1.2 1.5 0.3 1.7 27.8 1,330 YD225
2 × 35 2 1.2 1.6 0.3 1.8 30.5 1,639 YD235
2 × 50 2 1.4 1.7 0.45 2 34.7 2,163 YD250
TCu/MGT/EPR/ZH/GSWB/ZH
0.6/1 kV SW4
BS 7917
Number and Class of Nominal Nominal Diameter of Nominal Approximate Approximate UKOOA
cross-sectional conductor thickness of thickness of steel wires in thickness of overall diameter net weight of Code
area of conductor insulation inner sheath braid outer sheath of cable cables SW4
162 2 × 120
3 × 1.5
2
5
1.6
0.8
2.2
1.1
0.45
0.3
2.5
1.2
48
14.2
4,483
319
YD20A
YD302
3 × 2.5 2 0.8 1.1 0.3 1.3 15.6 378 YD303
3×4 2 1 1.2 0.3 1.3 17.7 502 YD304
3×6 2 1 1.2 0.3 1.4 19.1 596 YD306
3 × 10 2 1 1.3 0.3 1.5 21.5 803 YD310
3 × 16 2 1 1.4 0.3 1.6 24.4 1,102 YD316
3 × 25 2 1.2 1.6 0.3 1.8 29.7 1,611 YD325
3 × 35 2 1.2 1.7 0.45 1.9 33.2 2,138 YD335
3 × 50 2 1.4 1.8 0.45 2 37.1 2,669 YD350
3 × 70 2 1.4 2 0.45 2.2 41.5 3,529 YD370
3 × 95 2 1.6 2.2 0.45 2.4 47.3 4,730 YD395
3 × 120 2 1.6 2.3 0.45 2.6 51.1 5,642 YD30A
4 × 1.5 2 0.8 1.1 0.3 1.3 15.6 366 YD402
4 × 2.5 2 0.8 1.1 0.3 1.3 16.7 440 YD403
4×4 2 1 1.2 0.3 1.4 19.3 594 YD404
4×6 2 1 1.3 0.3 1.5 21 727 YD406
4 × 10 2 1 1.4 0.3 1.6 23.6 973 YD410
4 × 16 2 1 1.5 0.3 1.7 26.9 1,345 YD416
4 × 25 2 1.2 1.7 0.45 1.9 33.3 2,110 YD425
4 × 35 2 1.2 1.8 0.45 2 36.5 2,671 YD435
4 × 50 2 1.4 1.9 0.45 2.2 40.7 3,350 YD450
4 × 70 2 1.4 2.1 0.45 2.4 45.8 4,436 YD470
4 × 95 2 1.6 2.3 0.45 2.6 52.2 5,960 YD495
4 × 120 2 1.6 2.5 0.45 2.8 57.7 7,093 YD40A
5 × 1.5 5 0.8 1.1 0.3 1.3 17.5 464 –
5 × 2.5 2 0.8 1.2 0.3 1.3 18.7 566 –
5 × 4* 2 1 1.3 0.3 1.5 21.3 698 –
5 × 6* 2 1 1.3 0.3 1.5 23.1 851 –
5 × 25 * 2 1.2 1.8 0.45 2.0 35.5 2,425 –
5 × 70 * 2 1.4 2.2 0.45 2.6 49.9 5,276 –
5 × 95 * 2 1.6 2.4 0.45 2.7 56.9 7,099 –
TCu/MGT/EPR/ZH/GSWB/ZH
0.6/1 kV SW4
BS 7917
Number and Class of Nominal Nominal Diameter of Nominal Approximate Approximate UKOOA
cross-sectional conductor thickness of thickness of steel wires in thickness of overall diameter net weight of Code
area of conductor insulation inner sheath braid outer sheath of cable cables SW4
* Based on standard
All the information contained in this document – including tables and diagrams – is given in good faith and believed to be correct at the
time of publication. The information does not constitute a warranty nor representation for which TELE-FONIKA Kable assumes legal
responsibility. TELE-FONIKA Kable reserves rights to introduce changes to the document at any time.
NEK606
UX P15 TCu/EVA
0.6/1 kV
NEK TS 606 Code P15, IEC 60092-353-Design guidelines
CONSTRUCTION
166
Code letter
CHARACTERISTIC
Maximum conductor operating temperature: +90 oC
Maximum conductor temperature during short circuit: +250 oC
Lowest ambient temperature for fixed installation: -40 oC
Lowest installation temperature: -15 oC
Oil resistance: IEC 60092-360 SHF2. I RM 902
(100 oC /24h)
Mud resistance: NEK 606 (SHF MUD. SHF2)
Minimum bending radius:
During installation 8D
Fixed installed 6D
D – overall diameter of cable
Fire performance
Flame retardant: IEC 60332-3-22 (Category A)
Smoke emission: IEC 61034-2
Corrosive gas emission: IEC 60754-1
UX P15 TCu/EVA
0.6/1 kV
Applications
•• Insulated conductor for earthing and bonding services
•• Meets the MUD resistance requirement in NEK TS 606:2009
•• Other industrial applications
167
Approvals
DNV-GL, ABS
Details related to particular Approvals are informative only. Please contact manufacturer to confirm whether
the required cross-sections are covered by the Certificate.
168 CONSTRUCTION
Code letter
CHARACTERISTIC
Maximum conductor operating temperature: +90 oC
Maximum conductor temperature during short circuit: +250 oC
Lowest ambient temperature for fixed installation: -40 oC
Lowest installation temperature: -15 oC 169
Oil resistance: IEC 60092-360 SHF2. I RM 902 (100 o C/24 h)
Mud resistance: NEK 606 (SHF MUD. SHF2)
Minimum bending radius for cable Overall diameter Minimum bending radius
with overall diameter (D): of cable (D)
D < 25 mm 4D
D > 25 mm 6D
D – overall diameter of cable
Fire performance
Flame retardant IEC 60332-3-22 (Category A)
Smoke emission: IEC 61034-2
Corrosive gas emission: IEC 60754-1
Applications
•• Fixed installation for power control and lighting in both EX- and safe areas, general purposes
•• For installation in areas exposed to MUD and drilling/cleaning fluids
•• Meets the MUD resistance requirement in NEK TS 606:2009
•• For fixed wiring installations on Oil and Gas Rigs,
Shipboard and other marine applications requiring screened cable for EMC
•• Other industrial applications.
RFOU P1/P8 & RFOU EMC
0.6/1 (1.2) kV
EPR/EPR/TCWB/EVA
Approvals
DNV-GL, ABS
Details related to particular Approvals are informative only. Please contact manufacturer to confirm whether
the required cross-sections are covered by the Certificate.
170
Standard length cable packing: 1,000 m on drums
Other forms of packing and delivery are available on request
N × mm 2 mm mm mm mm mm kg/km
1 × 16/2.5 * 1 1.1 0.2 1.2 12.8 328
1 × 25/4 * 1.2 1.1 0.2 1.2 14.5 454
1 × 35/6 * 1.2 1.1 0.3 1.3 16.3 610
1 × 50/6 * 1.4 1.1 0.3 1.4 18 753
1 × 70/10 * 1.4 1.1 0.3 1.4 19.7 1,010
1 × 95/10 * 1.6 1.1 0.3 1.5 22.3 1,312
1 × 120/10 * 1.6 1.2 0.3 1.6 24.1 1,562
1 × 150/10 * 1.8 1.2 0.3 1.6 26.1 1,871
1 × 185/10 * 2 1.2 0.3 1.7 28.7 2,286
1 × 240/16 * 2.2 1.2 0.3 1.8 31.8 2,987
1 × 300/16 * 2.4 1.2 0.3 1.9 34.7 3,544
2 × 1.5/4 1 1.1 0.2 1.2 12.7 263
2 × 2.5/4 1 1.1 0.2 1.2 13.6 299
2 × 4/6 1 1.1 0.3 1.3 15.5 420
2 × 6/6 1 1.1 0.3 1.3 16.6 485
2 × 10/10 1 1.1 0.3 1.4 18.6 613
2 × 16/16 1 1.1 0.4 1.5 21.5 881
2 × 25/16 * 1.2 1.2 0.4 1.6 25.4 1,240
2 × 35/16 1.2 1.2 0.3 1.7 27.5 1,510
2 × 50/25 1.4 1.2 0.4 1.8 31.1 1,929
2 × 70/35 1.4 1.2 0.5 1.9 35.2 2,656
2 × 95/50 1.6 1.4 0.5 2.1 40.7 3,686
2 × 120/70 1.6 1.4 0.5 2.2 43.9 4,441
3 × 1.5/4 1 1.1 0.2 1.2 13.3 267
3G1.5 1 1.1 0.2 1.2 13.3 271
RFOU P1/P8 & RFOU EMC
0.6/1 (1.2) kV
EPR/EPR/TCWB/EVA
Without approvals
Size Insulation Thickness Diameter Thickness Approximate Approximate
thickness inner covering of braid wire outer sheath outer diameter weight of cable
N × mm 2 mm mm mm mm mm kg/km
1 × 10/2.5 1.0 1.1 0.2 1.2 11.7 254 173
3 × 35 RF/16 1.2 1.2 0.3 1.7 28.5 1,698
3G70 1.4 1.3 0.3 2.0 37 3,047
3 × 95 RF/50 1.6 1.4 0.5 2.2 44.5 4,347
3G120 1.6 1.3 0.4 2.3 46.4 5,050
3G150 1.8 1.5 0.4 2.5 51.3 6,301
3 × 150/70 1.8 1.5 0.5 2.5 51.7 6,560
3G185 2 1.5 0.4 2.7 56.5 7,581
3 × 185/95 ** 2 1.5 0.5 2.7 58.9 8,155
3G240 2.2 1.6 0.4 3.1 64.0 9,577
3G300 2.4 1.7 0.4 3.1 70.1 11,940
4G150 1.8 1.5 0.4 2.7 56.6 7,785
4G185 2 1.7 0.4 2.9 62.9 9,647
4G240 2.2 1.7 0.4 3.1 70.5 12,325
5 × 10/10 1 1.1 0.3 1.6 23.4 1,055
5G95 1.6 1.5 0.4 2.5 52.3 6,388
6G2.5 1 1.1 0.3 1.4 18.5 537
7G1.5 1 1.1 0.3 1.4 18.3 484
7G4 1 1.1 0.3 1.5 22.0 807
9G1.5 1 1.1 0.3 1.5 20.7 653
10G1.5 1 1.1 0.3 1.5 21 633
10 × 1.5/10 1 1.1 0.3 1.5 21 633
10 × 2.5/10 1 1.1 0.3 1.6 22.9 794
12G4 1 1.1 0.3 1.7 26.3 1,198
14G2.5 1 1.1 0.3 1.6 24.5 1,057
14G4 1 1.1 0.3 1.7 27.5 1,240
15 × 2.5/10 1 1.1 0.3 1.7 25.9 1,040
16G1.5 1 1.1 0.3 1.6 23.7 920
16 × 2.5/10 1 1.1 0.3 1.7 25.9 1,063
17G1.5 1 1.1 0.3 1.6 24.7 1,005
20G2.5 1 1.1 0.3 1.8 28.5 1,266
RFOU P1/P8 & RFOU EMC
0.6/1 (1.2) kV
EPR/EPR/TCWB/EVA
** Double braided
BFOU P5/P12 & BFOU EMC
EPR/EPR/TCWB/EVA
0.6/1 (1.2) kV
NEK TS 606 Code P5/P12, IEC 60092-353-Design guidelines
CONSTRUCTION 175
Code letter
CHARACTERISTIC
Maximum conductor operating temperature: +90 oC
Maximum conductor temperature during short circuit: +250 oC
Lowest ambient temperature for fixed installation: -40 oC
Fire performance
Flame retardant: IEC 60332-3-22 (Category A)
Fire resistant: IEC 60331
Smoke emission: IEC 61034-2
Corrosive gas emission: IEC 60754-1
Applications
•• Fixed installation for power control and lighting in both EX- and safe areas emergency
and critical systems where requirement for fire resistant exists
•• For installation in areas exposed to MUD and drilling/cleaning fluids
•• Meets the MUD resistance requirement in NEK TS 606:2009
•• For fixed wiring installations on Oil and Gas Rigs. Shipboard and other marine applications
requiring screened cable for EMC
•• Other industrial applications
BFOU P5/P12 & BFOU EMC
EPR/EPR/TCWB/EVA
0.6/1 (1.2) kV
Approvals
DNV-GL, ABS
Details related to particular Approvals are informative only. Please contact manufacturer to confirm whether
the required cross-sections are covered by the Certificate.
177
Standard length cable packing: 1,000 m on drums
Other forms of packing and delivery are available on request
N × mm 2 mm mm mm mm mm kg/km
1 × 16/4 * 1 1.1 0.2 1.2 13.4 362
1 × 25/6 * 1.2 1.1 0.3 1.3 15.7 534
1 × 35/6 * 1.2 1.1 0.3 1.3 16.9 654
1 × 50/10 * 1.4 1.1 0.3 1.4 18.6 801
1 × 70/10 * 1.4 1.1 0.3 1.4 20.3 1,010
1 × 95/10 * 1.6 1.1 0.3 1.5 22.9 1,342
1 × 120/10 * 1.6 1.2 0.3 1.6 24.8 1,600
1 × 150/10 * 1.8 1.2 0.3 1.7 26.9 1,922
1 × 185/10 * 2 1.2 0.3 1.7 29.1 2,323
1 × 240/16 * 2.2 1.2 0.3 1.8 32.3 2,946
1 × 300/16 * 2.4 1.2 0.3 1.9 35.3 3,586
2 × 1.5/4 * 1 1.1 0.2 1.2 14.2 279
2 × 2.5/6 * 1 1.1 0.3 1.3 15.6 364
2 × 4/6 1 1.1 0.3 1.3 16.7 429
2 × 6/6 1 1.1 0.3 1.4 18 512
2 × 10/10 1 1.1 0.3 1.4 19.8 650
2 × 16/16 1 1.1 0.4 1.5 22.8 926
2 × 25/16 1.2 1.2 0.4 1.6 26.7 1,296
2 × 35/16 * 1.2 1.2 0.3 1.7 28.8 1,539
2 × 50/25 1.4 1.4 0.4 1.8 32.8 2,015
2 × 70/35 1.4 1.6 0.5 2 37.6 2,842
3G1.5 1 1.1 0.3 1.3 15.4 349
3 × 1.5/6 1 1.1 0.3 1.3 15.4 361
3G2.5 1 1.1 0.3 1.3 16.4 404
BFOU P5/P12 & BFOU EMC
EPR/EPR/TCWB/EVA
0.6/1 (1.2) kV
178
3 × 6/6 1 1.1 0.3 1.4 18.9 585
3 × 10/10 1 1.1 0.3 1.5 21.1 768
3 × 16/16 1 1.1 0.4 1.5 24 1,096
3 × 25/16 1.2 1.2 0.3 1.7 28 1,497
3G35 1.2 1.2 0.3 1.8 30.6 1,898
3 × 35/16 * 1.2 1.2 0.3 1.8 30.6 1,926
3 × 50/25 1.4 1.2 0.4 1.9 34.5 2,476
3 × 70/35 1.4 1.4 0.5 2 39.2 3,361
3 × 95/50 1.6 1.4 0.5 2.2 44.8 4,589
3 × 120/70 1.6 1.4 0.5 2.4 48.5 5,447
3 × 185/95 2 2 0.5 3 59.7 6,030
4 × 1.5/6 1 1.1 0.3 1.3 16.6 450
4G1.5 1 1.1 0.3 1.3 16.6 420
4 × 2.5/6 1 1.1 0.3 1.3 17.6 480
4G2.5 1 1.1 0.3 1.3 17.6 460
4 × 4/6 1 1.1 0.3 1.4 19.1 610
4G4 1 1.1 0.3 1.4 19.1 660
4 × 6/6 1 1.1 0.3 1.4 20.4 770
4G6 1 1.1 0.3 1.4 20.4 720
4 × 10/10 1 1.1 0.3 1.5 22.8 990
4G10 1 1.1 0.3 1.5 22.8 990
4 × 16/16 1 1.2 0.4 1.6 26.4 1,420
4G16 1 1.2 0.3 1.6 26 1,330
4 × 25/16 1.2 1.2 0.3 1.7 29 1,970
4G25 1.2 1.2 0.3 1.7 29 1,930
4 × 35/16 * 1.2 1.2 0.3 1.9 33.5 2,490
4G35 1.2 1.2 0.3 1.9 33.5 2,470
4 × 50/25 1.4 1.4 0.4 2 38.5 3,380
4G50 1.4 1.4 0.3 2 38 3,290
4 × 70/35 1.4 1.4 0.4 2.2 43 4,610
4G70 1.4 1.4 0.4 2.2 43 4,520
4 × 95/50 1.6 1.6 0.5 2.4 49.8 6,150
BFOU P5/P12 & BFOU EMC
EPR/EPR/TCWB/EVA
0.6/1 (1.2) kV
179
4G120 1.6 1.6 0.4 2.5 54 7,180
4G150 1.8 1.6 0.5 2.7 59 8,910
4G185 2 1.8 0.4 2.9 64.8 10,830
5G1.5 1 1.1 0.3 1.4 18 454
5 × 1.5/6 1 1.1 0.3 1.4 18 460
5G2.5 1 1.1 0.3 1.4 19.1 475
5 × 2.5/6 1 1.1 0.3 1.4 19.1 487
5G4 1 1.1 0.3 1.4 20.5 651
5G6 1 1.1 0.3 1.5 22.3 798
5G10 1 1.2 0.3 1.6 25.1 1,085
5G16 1 1.2 0.3 1.7 28.5 1,510
5G25 1.2 1.2 0.3 1.8 33.4 2,172
5G35 1.2 1.4 0.3 2 37.3 2,825
5G50 1.4 1.4 0.4 2.2 42.2 3,651
5G70 1.4 1.4 0.4 2.3 47.1 4,845
5G95 1.6 1.6 0.5 2.6 54 7,140
7 × 1.5/6 1 1.1 0.3 1.4 17 540
7 × 2.5/6 1 1.1 0.3 1.4 22 630
12 × 1.5/10 1 1.2 0.3 1.6 21.5 810
12 × 2.5/10 1 1.2 0.3 1.6 25.5 990
19 × 1.5/10 1 1.2 0.3 1.7 25 1,100
19 × 2.5/16 1 1.2 0.3 1.8 30 1,370
27 × 1.5/16 1 1.4 0.3 2 34.7 1,565
27 × 2.5/25 1 1.4 0.3 2 37.3 1,994
37 × 1.5/16 1 1.4 0.3 2 39.6 1,987
37 × 2.5/25 1 1.4 0.4 2.2 43.5 2,628
Without approvals
Size Insulation Thickness Diameter Thickness Approximate Approximate
thickness inner covering of braid wire outer covering outer diameter weight of cable
N × mm 2 mm mm mm mm mm kg/km
** Double braided
RFOU (i) S1/S5 & RFOU (i) EMC
150/250 (300) V
EPR/EPR/TCWB/EVA
NEK TS 606 Code S1/S5, IEC 60092-376-Design guidelines
CHARACTERISTIC
Maximum conductor operating temperature: +90 oC
Maximum conductor temperature during short circuit: +250 oC
Lowest ambient temperature for fixed installation: -40 oC
Fire performance
Flame retardant IEC 60332-3-22 (Category A)
Smoke emission: IEC 61034-2
Corrosive gas emission: IEC 60754-1
Applications
•• Fixed installation for instrumentation, communication, control and alarm system in both EX- and safe areas
•• Meets the MUD resistance requirement in NEK TS 606
•• For fixed wiring installations on Oil and Gas Rigs, Shipboard and other marine applications
requiring screened cable for EMC
•• Other industrial applications
Approvals
DNV-GL, ABS
Details related to particular Approvals are informative only. Please contact manufacturer to confirm whether
the required cross-sections are covered by the Certificate.
N × 2 × mm 2 mm mm mm mm mm kg/km
1 × 2 × 0.75 2 0.6 1.1 0.2 1.1 10.3 148
2 × 2 × 0.75 2 0.6 1.1 0.2 1.2 14.4 248 183
4 × 2 × 0.75 2 0.6 1.1 0.3 1.3 15.6 355
8 × 2 × 0.75 2 0.6 1.1 0.3 1.5 19.2 554
12 × 2 × 0.75 2 0.6 1.4 0.3 1.6 22.9 775
16 × 2 × 0.75 2 0.6 1.9 0.3 1.7 26.5 1,024
19 × 2 × 0.75 2 0.6 1.9 0.3 1.7 28.1 1,153
24 × 2 × 0.75 2 0.6 2.1 0.3 1.9 31.3 1,421
1 × 3 × 0.75 2 0.6 1.1 0.2 1.1 10.6 162
2 × 3 × 0.75 2 0.6 1.1 0.3 1.3 15.2 308
4 × 3 × 0.75 2 0.6 1.1 0.3 1.4 17 429
8 × 3 × 0.75 2 0.6 1.1 0.3 1.6 21.7 698
12 × 3 × 0.75 2 0.6 1.4 0.3 1.7 25.5 972
16 × 3 × 0.75 2 0.6 2.1 0.3 1.8 29.8 1,310
19 × 3 × 0.75 2 0.6 2.1 0.3 1.8 31.7 1,482
24 × 3 × 0.75 2 0.6 2.5 0.4 2 36.1 1,859
1 × 2 × 1.5 2 0.7 1.1 0.2 1.1 11.6 187
2 × 2 × 1.5 2 0.7 1.1 0.3 1.3 17.6 384
4 × 2 × 1.5 2 0.7 1.1 0.3 1.4 20.0 546
8 × 2 × 1.5 2 0.7 1.1 0.3 1.7 23.1 809
12 × 2 × 1.5 2 0.7 1.4 0.3 1.8 27.8 1,156
16 × 2 × 1.5 2 0.7 1.9 0.3 1.9 32.1 1,524
19 × 2 × 1.5 2 0.7 1.9 0.3 1.9 34.2 1,732
24 × 2 × 1.5 2 0.7 2.3 0.4 2.2 39.1 2,287
1 × 3 × 1.5 2 0.7 1.1 0.2 1.1 12.2 216
2 × 3 × 1.5 2 0.7 1.1 0.3 1.4 18 428
4 × 3 × 1.5 2 0.7 1.1 0.3 1.5 20.2 622
8 × 3 × 1.5 2 0.7 1.1 0.3 1.8 26.3 1,047
12 × 3 × 1.5 2 0.7 1.4 0.3 1.9 31.1 1,488
16 × 3 × 1.5 2 0.7 2.3 0.4 2 37.1 2,030
24 × 3 × 1.5 2 0.7 2.5 0.4 2.3 44.1 2,983
1 × 2 × 2.5 2 0.7 1.1 0.2 1.1 12.4 222
RFOU (i) S1/S5 & RFOU (i) EMC
150/250 (300) V
EPR/EPR/TCWB/EVA
184
Without approvals
Size Class of Insulation Thickness of Diameter Thickness of Approximate Approximate
conductor thickness inner sheath of braid wire outer sheath overall net weight of
diameter cable
N × 2 × mm 2 mm mm mm mm mm kg/km
5 × 2 × 0.75 2 0.6 1.1 0.3 1.3 18.1 444
10 × 2 × 0.75 2 0.6 1.1 0.3 1.5 24.1 734
20 × 2 × 0.75 2 0.6 1.9 0.3 1.7 31.9 1,321
4 × 2 × 2.5 2 0.7 1.1 0.3 1.5 21.9 677
8 × 2 × 2.5 2 0.7 1.1 0.3 1.7 29.9 1,167
16 × 2 × 2.5 2 0.7 1.1 0.3 1.9 37.2 1,969
24 × 2 × 2.5 2 0.7 1.2 0.4 2.2 46.7 2,968
1 × 3 × 2.5 2 0.7 1 0.2 1.2 13.0 265
4 × 3 × 2.5 2 0.7 1.1 0.3 1.5 24.0 840
16 × 3 × 2.5 2 0.7 1.2 0.4 2.1 42.2 2,705
1 × 4 × 2.5 2 0.7 1 0.2 1.2 13.9 309
4×3×1 2 0.6 1 0.3 1.4 22.5 635
RFOU (c) S2/S6 & RFOU (c) EMC
150/250 (300) V
EPR/EPR/TCWB/EVA
NEK TS 606 Code S2/S6, IEC 60092-376-Design guidelines
CONSTRUCTION 185
Code letter
CHARACTERISTIC
Maximum conductor operating temperature: +90 oC
Maximum conductor temperature during short circuit: +250 oC
Lowest ambient temperature for fixed installation: -40 oC
186 Lowest installation temperature: -15 oC
Oil resistance: IEC 60092-360 SHF2, I RM 902 (100 oC/24h)
Mud resistance: NEK 606 (SHF MUD, SHF2)
Minimum bending radius: 6D
D – overall diameter of cable
Fire performance
Flame retardant IEC 60332-3-22 (Category A)
Smoke emission: IEC 61034-2
Corrosive gas emission: IEC 60754-1
Applications
•• Fixed installation for instrumentation, communication, control and alarm system in both EX-
and safe areas
•• Meets the MUD resistance requirement in NEK TS 606
•• For fixed wiring installations on Oil and Gas Rigs, Shipboard and other marine applications
requiring screened cable for EMC
•• Other industrial applications
Approvals
DNV-GL, ABS
Details related to particular Approvals are informative only. Please contact manufacturer to confirm
whether the required cross-sections are covered by the Certificate.
N × 2 × mm 2 mm mm mm mm mm kg/km
2 × 2 × 0.75 2 0.6 1.1 0.2 1.2 11.4 187
4 × 2 × 0.75 2 0.6 1.1 0.3 1.3 15.9 337 187
8 × 2 × 0.75 2 0.6 1.1 0.3 1.5 21.7 496
12 × 2 × 0.75 2 0.6 1.4 0.3 1.5 24.4 685
16 × 2 × 0.75 2 0.6 1.9 0.3 1.6 26.5 899
19 × 2 × 0.75 2 0.6 1.9 0.3 1.7 28.3 1,017
24 × 2 × 0.75 2 0.6 2.1 0.3 1.8 31.3 1,231
2 × 3 × 0.75 2 0.6 1.1 0.3 1.3 15.4 306
4 × 3 × 0.75 2 0.6 1.1 0.3 1.3 17 403
8 × 3 × 0.75 2 0.6 1.1 0.3 1.6 21.8 639
12 × 3 × 0.75 2 0.6 1.4 0.3 1.6 25.5 879
16 × 3 × 0.75 2 0.6 2.1 0.3 1.7 29.9 1,183
24 × 3 × 0.75 2 0.6 2.5 0.4 2 36.3 1,680
2 × 2 × 1.5 2 0.7 1.1 0.3 1.3 13.6 288
4 × 2 × 1.5 2 0.7 1.1 0.3 1.4 18.8 475
8 × 2 × 1.5 2 0.7 1.1 0.3 1.6 23.3 740
10 × 2 × 1.5 2 0.7 1.2 0.3 1.7 26.4 900
12 × 2 × 1.5 2 0.7 1.4 0.3 1.7 27.9 1,031
16 × 2 × 1.5 2 0.7 1.9 0.3 1.8 32.2 1,353
19 × 2 × 1.5 2 0.7 1.9 0.3 1.9 34.4 1,543
24 × 2 × 1.5 2 0.7 2.3 0.3 2.1 39.1 1,932
2 × 3 × 1.5 2 0.7 1.1 0.3 1.4 18.2 420
4 × 3 × 1.5 2 0.7 1.1 0.3 1.4 20.3 585
8 × 3 × 1.5 2 0.7 1.1 0.3 1.7 26.5 975
12 × 3 × 1.5 2 0.7 1.4 0.3 1.8 31.1 1,357
16 × 3 × 1.5 2 0.7 2.1 0.4 1.9 36.7 1,810
24 × 3 × 1.5 2 0.7 2.5 0.4 2.2 44.1 2,593
2 × 2 × 2.5 2 0.7 1.1 0.3 1.4 14.8 358
4 × 2 × 2.5 2 0.7 1.1 0.3 1.4 20.6 594
8 × 2 × 2.5 2 0.7 2.1 0.3 1.8 28.1 1,110
12 × 2 × 2.5 2 0.7 2.1 0.3 1.8 32.4 1,460
RFOU (c) S2/S6 & RFOU (c) EMC
150/250 (300) V
EPR/EPR/TCWB/EVA
Without approvals
Size Class of Insulation Thickness of Diameter Thickness of Approximate Approximate
conductor thickness inner sheath of braid wire outer sheath overall net weight of
diameter cable
188 N × 2 × mm 2 mm mm mm mm mm kg/km
6 × 2 × 0.75 2 0.6 1.1 0.3 1.4 19.0 451
10 × 2 × 0.75 2 0.6 1.1 0.3 1.5 23.3 629
14 × 2 × 0.75 2 0.6 1.4 0.3 1.6 25.8 797
1×2×1 2 0.6 1.0 0.2 1.1 11.8 199
2×2×1 2 0.6 1.0 0.2 1.2 14.5 250
4×2×1 2 0.6 1.0 0.3 1.4 20.1 484
6×2×1 2 0.6 1.0 0.3 1.4 19.6 490
10 × 2 × 1 2 0.6 1.0 0.3 1.5 24.2 702
12 × 2 × 1 2 0.6 1.0 0.3 1.6 25.1 775
3 × 2 × 1.5 2 0.7 1.0 0.3 1.3 17.6 408
5 × 2 × 1.5 2 0.7 1.0 0.3 1.4 20.7 552
6 × 3 × 1.5 2 0.7 1.0 0.3 1.6 24.8 803
20 × 2 × 1.5 2 0.7 1.0 0.3 1.9 35.4 1,479
16 × 2 × 2.5 2 0.7 1.0 0.3 1.9 35.8 1,648
24 × 2 × 2.5 2 0.7 1.2 0.4 2.2 45.1 2,496
4 × 3 × 2.5 2 0.7 1.0 0.3 1.5 23.2 761
16 × 3 × 2.5 2 0.7 1.2 0.4 2.1 40.9 2,373
BFOU (i) S3/S7 & BFOU (i) EMC
150/250 (300) V
MGT/EPR/EPR/TCWB/EVA
NEK TS 606 Code S3/S7, IEC 60092-376-Design guidelines
CHARACTERISTIC
Maximum conductor operating temperature: +90 oC
Maximum conductor temperature during short circuit: +250 oC
Lowest ambient temperature for fixed installation: -40 oC
Fire performance
Flame retardant: IEC 60332-3-22 (Category A)
Fire resistant: IEC 60331
Smoke emission: IEC 61034-2
Corrosive gas emission: IEC 60754-1
Applications
•• Fixed installation for instrumentation, communication, control and alarm system in both EX-
and safe areas emergency and critical systems where requirements for fire resistance exists.
•• Meets the MUD resistance requirement in NEK TS 606
•• For fixed wiring installations on Oil and Gas Rigs, Shipboard and other marine applications
requiring screened cable for EMC
•• Other industrial applications
Approvals
DNV-GL, ABS
Details related to particular Approvals are informative only. Please contact manufacturer to confirm
whether the required cross-sections are covered by the Certificate.
BFOU (i) S3/S7 & BFOU (i) EMC
150/250 (300) V
MGT/EPR/EPR/TCWB/EVA
191
diameter cable
N × 2 × mm 2 mm mm mm mm mm kg/km
1 × 2 × 0.75 2 0.6 1.1 0.2 1.1 11.7 171
2 × 2 × 0.75 2 0.6 1.1 0.3 1.3 13.5 258
4 × 2 × 0.75 2 0.6 1.1 0.3 1.4 18.8 438
8 × 2 × 0.75 2 0.6 1.1 0.3 1.6 23.4 680
12 × 2 × 0.75 2 0.6 1.4 0.3 1.7 28 949
16 × 2 × 0.75 2 0.6 1.9 0.3 1.8 32.3 1,250
19 × 2 × 0.75 2 0.6 1.9 0.3 1.9 34.6 1,422
24 × 2 × 0.75 2 0.6 2.3 0.4 2.1 39.4 1,879
1 × 3 × 0.75 2 0.6 1.1 0.2 1.1 12.2 200
2 × 3 × 0.75 2 0.6 1.1 0.3 1.4 18.2 384
4 × 3 × 0.75 2 0.6 1.1 0.3 1.4 20.3 521
8 × 3 × 0.75 2 0.6 1.1 0.3 1.7 26.6 860
12 × 3 × 0.75 2 0.6 1.4 0.3 1.8 31.3 1,192
16 × 3 × 0.75 2 0.6 2.1 0.4 1.9 36.9 1,603
19 × 3 × 0.75 2 0.6 2.3 0.4 2 39.9 1,866
24 × 3 × 0.75 2 0.6 2.5 0.4 2.2 44.4 2,395
1 × 2 × 1.5 2 0.7 1.1 0.2 1.1 13 214
2 × 2 × 1.5 2 0.7 1.1 0.3 1.4 20.1 454
4 × 2 × 1.5 2 0.7 1.1 0.3 1.5 23.2 648
8 × 2 × 1.5 2 0.7 1.1 0.3 1.7 27.3 947
12 × 2 × 1.5 2 0.7 1.4 0.3 1.9 36.5 1,519
16 × 2 × 1.5 2 0.7 2.1 0.4 2 38.7 1,810
19 × 2 × 1.5 2 0.7 1.9 0.4 2 40.9 2,092
24 × 2 × 1.5 2 0.7 2.3 0.4 2.3 46.2 2,657
1 × 3 × 1.5 2 0.7 1.1 0.2 1.1 13.6 259
2 × 3 × 1.5 2 0.7 1.1 0.3 1.5 21 508
4 × 3 × 1.5 2 0.7 1.1 0.3 1.6 23.8 730
8 × 3 × 1.5 2 0.7 1.1 0.3 1.8 31.1 1,221
12 × 3 × 1.5 2 0.7 1.6 0.4 2 37.7 1,765
BFOU (i) S3/S7 & BFOU (i) EMC
150/250 (300) V
MGT/EPR/EPR/TCWB/EVA
Without approvals
Size Class Insulation Thickness of Diameter Thickness of Approximate Approximate
of conductor thickness inner sheath of braid wire outer sheath overall net weight of
diameter cable
N × 2 × mm 2 mm mm mm mm mm kg/km
1×2×1 2 0.6 1.0 0.2 1.1 11.9 187
5 × 2 × 1.5 2 0.7 1.1 0.3 1.5 25.1 754
6 × 2 × 1.5 2 0.7 1.1 0.3 1.6 27.4 870
10 × 2 × 1.5 2 0.7 1.1 0.3 1.8 34.6 1,299
1 × 2 × 2.5 2 0.7 1.1 0.2 1.1 13.1 222
5 × 2 × 2.5 2 0.7 1.1 0.3 1.6 27.4 953
12 × 2 × 2.5 2 0.7 1.1 0.3 1.9 39.1 1,838
20 × 2 × 2.5 2 0.7 1.2 0.4 2.2 49.1 2,855
1 × 3 × 2.5 2 0.7 1.1 0.2 1.2 14.8 312
2 × 3 × 2.5 2 0.7 1.1 0.3 1.5 23.9 653
4 × 3 × 2.5 2 0.7 1.1 0.3 1.6 27.7 985
12 × 3 × 2.5 2 0.7 1.3 0.4 2.1 44.6 2,532
BFOU (c) S4/S8 & BFOU (c) EMC
150/250 (300) V
MGT/EPR/EPR/TCWB/EVA
NEK TS 606 Code S4/S8, IEC 60092-376-Design guidelines
CHARACTERISTIC
Maximum conductor operating temperature: +90 oC
Maximum conductor temperature during short circuit: +250 oC
Lowest ambient temperature for fixed installation: -40 oC
Fire performance
Flame retardant: IEC 60332-3-22 (Category A)
Fire resistant: IEC 60331
Smoke emission: IEC 61034-2
Corrosive gas emission: IEC 60754-1
Applications
•• Fixed installation for instrumentation, communication, control and alarm system in both EX-
and safe areas emergency and critical systems where requirements for fire resistance exists.
•• Meets the MUD resistance requirement in NEK TS 606
•• For fixed wiring installations on Oil and Gas Rigs, Shipboard and other marine
applications requiring screened cable for EMC
•• Other industrial applications
Approvals
DNV-GL, ABS
Details related to particular Approvals are informative only. Please contact manufacturer to confirm
whether the required cross-sections are covered by the Certificate.
BFOU (c) S4/S8 & BFOU (c) EMC
150/250 (300) V
MGT/EPR/EPR/TCWB/EVA
195
diameter cable
N × 2 × mm 2 mm mm mm mm mm kg/km
2 × 2 × 0.75 2 0.6 1.1 0.3 1.3 13.7 258
4 × 2 × 0.75 2 0.6 1.1 0.3 1.4 19 416
8 × 2 × 0.75 2 0.6 1.1 0.3 1.5 23.4 612
12 × 2 × 0.75 2 0.6 1.4 0.3 1.6 28 842
16 × 2 × 0.75 2 0.6 1.9 0.3 1.7 32.3 1,104
19 × 2 × 0.75 2 0.6 1.9 0.3 1.8 34.6 1,247
24 × 2 × 0.75 2 0.6 2.3 0.4 2 39.4 1,561
2 × 3 × 0.75 2 0.6 1.1 0.3 1.3 18.2 372
4 × 3 × 0.75 2 0.6 1.1 0.3 1.4 20.5 497
8 × 3 × 0.75 2 0.6 1.1 0.3 1.6 22.7 703
12 × 3 × 0.75 2 0.6 1.4 0.3 1.8 31.5 1,091
16 × 3 × 0.75 2 0.6 2.1 0.4 1.9 37.1 1,463
24 × 3 × 0.75 2 0.6 2.5 0.4 2.1 44.4 2,157
2 × 2 × 1.5 2 0.7 1.1 0.3 1.4 19.7 435
4 × 2 × 1.5 2 0.7 1.1 0.3 1.4 21.8 551
8 × 2 × 1.5 2 0.7 1.1 0.3 1.7 27.5 868
12 × 2 × 1.5 2 0.7 1.4 0.3 1.8 32.9 1,207
16 × 2 × 1.5 2 0.7 1.9 0.4 1.9 38.4 1,580
24 × 2 × 1.5 2 0.7 2.3 0.4 2.3 46.4 2,379
2 × 3 × 1.5 2 0.7 1.1 0.3 1.4 21 492
4 × 3 × 1.5 2 0.7 1.1 0.3 1.5 24.9 742
8 × 3 × 1.5 2 0.7 1.1 0.3 1.8 34.4 1,139
12 × 3 × 1.5 2 0.7 1.4 0.4 1.9 39.6 1,578
16 × 3 × 1.5 2 0.7 2.3 0.4 2.1 44 2,274
24 × 3 × 1.5 2 0.7 2.7 0.4 2.4 52.8 3,210
2 × 2 × 2.5 2 0.7 1.1 0.3 1.4 16.6 402
4 × 2 × 2.5 2 0.7 1.1 0.3 1.5 23.7 683
8 × 2 × 2.5 2 0.7 1.1 0.3 1.8 30.1 1,103
16 × 2 × 2.5 2 0.7 2.3 0.4 2.1 42.9 2,228
4 × 3 × 2.5 2 0.7 1.1 0.3 1.6 26 929
BFOU (c) S4/S8 & BFOU (c) EMC
150/250 (300) V
MGT/EPR/EPR/TCWB/EVA
196
Without approvals
Size Insulation Thickness Diameter Thickness Approximate Approximate
thickness inner covering of braid wire outer covering outer diameter weight of cable
N × mm 2 mm mm mm mm mm kg/km
4×2×1 0.6 0.6 0.3 1.4 20.2 484
5×2×1 0.6 1.0 0.3 1.4 21.8 545
6×2×1 0.6 1.0 0.3 1.5 23.7 625
8×2×1 0.6 1.0 0.3 1.6 27.4 777
12 × 2 × 1 0.6 1.0 0.3 1.7 30.7 992
20 × 2 × 1 0.6 1.0 0.3 1.9 37.6 1,439
3×3×1 0.6 1.0 0.3 1.4 20.4 505
5×3×1 0.6 1.0 0.3 1.5 24.1 684
19 × 3 × 1 0.6 1.2 0.3 2.0 42.3 1,836
5 × 2 × 1.5 0.7 1.0 0.3 1.5 24.4 679
6 × 2 × 1.5 0.7 1.0 0.3 1.6 26.5 773
19 × 2 × 1.5 0.7 1.2 0.3 2.0 42.8 1,837
20 × 2 × 1.5 0.7 1.2 0.4 2.1 43.4 2,016
6 × 3 × 1.5 0.7 1.1 0.3 1.7 29.6 1,001
7 × 3 × 1.5 0.7 1.1 0.3 1.7 31.9 1,129
Classification Type cables
Bureau
RFOU (c) S2/S6 & RFOU (c) EMC 150/250 (300) V EPR/EPR/TCWB/EVA
BFOU (i) S3/S7 & BFOU (i) EMC 150/250 (300) V MGT/EPR/EPR/TCWB/EVA
BFOU (c) S4/S8 & BFOU (c) EMC 150/250 (300) V MGT/EPR/EPR/TCWB/EVA 197
ABS UX P15 TCu/EVA 0.6/1 kV
RFOU (c) S2/S6 & RFOU (c) EMC 150/250 (300) V EPR/EPR/TCWB/EVA
BFOU (i) S3/S7 & BFOU (i) EMC 150/250 (300) V MGT/EPR/EPR/TCWB/EVA
BFOU (c) S4/S8 & BFOU (c) EMC 150/250 (300) V MGT/EPR/EPR/TCWB/EVA
All the information contained in this document – including tables and diagrams – is given in good faith and believed to be correct at the
time of publication. The information does not constitute a warranty nor representation for which TELE-FONIKA Kable assumes legal
responsibility. TELE-FONIKA Kable reserves rights to introduce changes to the document at any time.
Technical section
To be read in conjunction
with the relevant cable datasheet
Installation recommendations
(in accordance with BS 6883:1999 appendix B)
Installation Temperature
Minimum recommended installation temperature for cables according to BS6883 is -15 oC
Current Ratings
(in accordance with IEC 60092-352 based on ambient air temperature of 45 oC)
200 24
27
6
6
6.5
6.5
9.5
9
30 6 6 9
37 5 6 8
The ambient temperature of 45 oC, on which the above current ratings are based, is considered as a standard value for the ambient air
temperature, generally applicable for any kind of ship or offshore platform in any climate.
2nd Character
203
(Class5)
01 1.0 mm 2 Flexible tinned copper 95 95 mm 2 Tinned copper (Class2)
(Class5)
02 1.5 mm 2 Flexible tinned copper 0A 120 mm 2 Tinned copper (Class2)
(Class5)
03 2.5 mm 2 Tinned copper (Class2) 0B 150 mm 2 Tinned copper (Class2)
04 4 mm 2
Tinned copper (Class2) 0C 185 mm 2
Tinned copper (Class2)
06 6 mm 2
Tinned copper (Class2) 0D 240 mm 2
Tinned copper (Class2)
10 10 mm 2
Tinned copper (Class2) 0E 300 mm 2
Tinned copper (Class2)
16 16 mm 2
Tinned copper (Class2) 0F 400 mm 2
Tinned copper (Class2)
25 25 mm 2
Tinned copper (Class2) 0G 500 mm 2
Tinned copper (Class2)
35 35 mm 2
Tinned copper (Class2) 0H 630 mm 2
Tinned copper (Class2)
50 50 mm 2
Tinned copper (Class2)
TELE-FONIKA Kable S.A.