GB 4 Dispenser Interface Converter Technical Guide
GB 4 Dispenser Interface Converter Technical Guide
GB 4 Dispenser Interface Converter Technical Guide
TECHNICAL GUIDE
(PCB board modification: GB-4)
CONTENT
REVISION HISTORY ................................................................................................................................................ 3
PURPOSE OF THE DOCUMENT .............................................................................................................................. 4
TECHNICAL FEATURES ........................................................................................................................................... 5
TECHNICAL SPECIFICATIONS ................................................................................................................................. 6
COMPLETE SET ...................................................................................................................................................... 7
PCB BOARD CONNECTORS OVERVIEW ................................................................................................................. 8
CONNECTION SCHEME TO PTS CONTROLLER ....................................................................................................... 9
CONNECTION SCHEME TO PC COM-PORT (DATA COMMUNICATION)...............................................................11
FIRMWARE UPDATE ............................................................................................................................................12
INSTALLATION REQUIREMENTS FOR PETROL STATION ......................................................................................14
EXAMPLES OF FUEL DISPENSERS CONNECTION SCHEMES .................................................................................16
Gilbarco dispenser connection scheme....................................................................................................... 16
Wayne Dresser dispenser connection scheme (current loop interface) ..................................................... 19
Bennett dispenser connection scheme (2-wire current loop interface) ..................................................... 20
Batchen Email dispenser connection scheme ............................................................................................. 21
Petrotec dispenser connection scheme ...................................................................................................... 22
Galileo dispenser connection scheme ......................................................................................................... 23
Prowalco dispenser connection scheme ..................................................................................................... 24
Petposan-S4 / Meksan-S4 / Europump-S4 dispensers connection scheme ................................................ 25
Yenen dispensers connection scheme ........................................................................................................ 26
Petposan-Beta / Europump-Beta dispensers connection scheme .............................................................. 27
EuroPump dispenser connection scheme ................................................................................................... 28
Mekser dispenser connection scheme ........................................................................................................ 29
Fuelsis dispenser connection scheme ......................................................................................................... 30
Falcon dispenser connection scheme.......................................................................................................... 31
ORDER INFORMATION ........................................................................................................................................32
REVISION HISTORY
Technotrade LLC
Ukraine, 04114 Kiev, Priorska str. 10, office 1
Tel: +38-044-502-46-55, +38-044-502-46-77
Web: www.technotrade.ua
Mail: mail@technotrade.ua
TECHNICAL FEATURES
GB interface converter (RS-485/RS-232 interface to 2-wire optically isolated active current loop interface
and backwards) is intended for communication with fuel dispensers, which use 2-wire current loop
interface, through interfaces:
− RS-232
− RS-485 (2-wire)
GB interface converter can be applied for communication with following brands of fuel dispensers, which
use 2-wire current loop for communication with control systems:
− AG Walker
− ANGI International
− Baransay
− Batchen
− Bennett
− CFT Clean Fuel
− COMPAC
− EuroPump
− Falcon
− Fuelsis
− Galileo
− Gilbarco
− Greenfield
− Kalvacha
− Kraus
− Maser
− Meksan
− Mekser
− PEC (Gallagher Fuel Systems)
− Petposan
− Petrotec
− Prowalco
− Salzkotten
− Tankanlagen Salzkotten
− Wayne Dresser (USCL communication protocol)
− Yenen
− others
TECHNICAL SPECIFICATIONS
Specification
PARAMETER VALUE
Power supply voltage 12 V DC
Current consumption 300 mA max
Temperature range From -40°C to +80°C
Weight 45 g
Dimensions 85 x58 x 25 mm
Technical characteristics
PARAMETER VALUE
Current value in current loop Adjustable using DIP-switches, located on PCB board, selected
interface values: 20 mA, 40 mA, 60 mA
Isolation in current loop interface Optical isolation
Current loop generator Сurrent generator
Communication ports
PORT NAME INTERFACE PURPOSE
RS-232
RS-232 Communication with a control system (POS
DATA (3 wires: TxD, RxD, Gnd)
terminal, cash register, OPT). Selection of
PORTS RS-485
RS-485 interface is made using DIP-switch.
(2-wires: line A, line B)
Pump ports Connection with fuel dispensers using 2 wires.
1…4 One dispenser is to be connected to each of
PUMP Optically isolated active
the pump ports. Selection of current value in
PORTS (2-wire current current loop
current loop of pump ports is made using DIP-
loop) switches.
PROGRAM RS-232
RS-232 Update of the interface converter firmware
PORT (3 wires: TxD, RxD, Gnd)
COMPLETE SET
Depending on the order code (see section “Order information”) GB interface can be supplied either in a
view of electrical board (variant of converter supply GB4-PCB-z), or installed in a mounting box with cables
inputs and a power switching button (variant of converter supply GB4-BOX-z).
Variant of GB-4 interface converter supply installed in a plastic box with cables inputs and
power switching button (GB4-BOX-z)
NOTE!
Configuration DIP-switch SA2 serves for selection of interface converter operation mode:
- switch 1 should be set in position “ON”
- switch 2 should be set in position “OFF”
- switch 3 should be set in position “OFF”
- switch 4 should be set in position “OFF”
DIP-switches SA3, SA4, SA5, SA6 in each of the pump ports serve for selection of current value in current
loop of each pump port and are adjusted in accordance with an image located on PCB board, which
indicates current value in pump ports in accordance with set DIP-switch positions. Possible current values:
- switch 1 OFF, switch 2 OFF => 20 mA
- switch 1 ON, switch 2 OFF => 40 mA
- switch 1 OFF, switch 2 ON => 40 mA
- switch 1 ON, switch 2 ON => 60 mA
Connection scheme to PTS-1 controller (information about PTS controller over fuel dispensers and ATG
systems can be found on PTS-1 controller web-page: http://www.technotrade.ua/fuel-pump-
controller.html):
Connection scheme to PTS-2 controller (information about PTS controller over fuel dispensers and ATG
systems can be found on PTS-2 controller web-page: http://www.technotrade.ua/pts2-forecourt-
controller.html):
✓ DIP-switch SA2:
o switch 1 should be set to position “ON”
o switch 2 should be set to position “OFF”
o switch 3 should be set to position “OFF”
o switch 4 should be set to position “OFF”
✓ DIP-switch SA1 should be in position “RS-485”
✓ LED HL1 “WORK” indicates normal operation of firmware, toggling its state once per second
✓ LED HL3 indicates presence of 12 V DC on the board, should be constantly shining
✓ Green and red LEDs “Tx” and “Rx”, which indicate communication exchange in DATA PORT, should be
blinking, which indicates communication with the PTS controller over RS-485 interface:
- in case if both LEDs “Rx” and “Tx” are not blinking – there are no requests from the control system
and no responses from the dispenser.
- in case if LED “Rx” is blinking and LED “Tx” is not blinking – there are requests from the control
system (LED “Rx” is blinking), but there are no responses from the dispenser.
- in case if LED “Rx” is blinking and LED “Tx” is blinking – there are requests from the control system
(LED “Rx” is blinking) and there are responses from the dispenser (LED “Tx” is blinking).
✓ LEDs on pump ports, where the dispenser is connected, should be constantly shining at closing of the
current loop interface
✓ DIP-switches on pump ports (SA3, SA4, SA5, SA6), where dispenser is connected, should be set in
accordance with a current value in current loop. Possible current values:
- switch 1 OFF, switch 2 OFF => 20 mA
- switch 1 ON, switch 2 OFF => 40 mA
- switch 1 OFF, switch 2 ON => 40 mA
- switch 1 ON, switch 2 ON => 60 mA
Control over dispensers through the interface converter from a personal computer:
connection to dispensers
COM-port
+ -+ -
TxD
+ -+ -
Personal computer
GB interface converter
✓ DIP-switch SA2:
o switch 1 should be set to position “ON”
o switch 2 should be set to position “OFF”
o switch 3 should be set to position “OFF”
o switch 4 should be set to position “OFF”
✓ DIP-switch SA1 should be in position “RS-232”
✓ LED HL1 “WORK” indicates normal operation of firmware, toggling its state once per second
✓ LED HL3 indicates presence of 12 V DC on the board, should be constantly shining
✓ Green and red LEDs “Tx” and “Rx”, which indicate communication exchange in DATA PORT, should be
blinking, which indicates communication with the PTS controller over RS-232 interface:
- in case if both LEDs “Rx” and “Tx” are not blinking – there are no requests from the control system
and no responses from the dispenser.
- in case if LED “Rx” is blinking and LED “Tx” is not blinking – there are requests from the control
system (LED “Rx” is blinking), but there are no responses from the dispenser.
- in case if LED “Rx” is blinking and LED “Tx” is blinking – there are requests from the control system
(LED “Rx” is blinking) and there are responses from the dispenser (LED “Tx” is blinking).
✓ LEDs on pump ports, where the dispenser is connected, should be constantly shining at closing of the
current loop interface
✓ DIP-switches on pump ports (SA3, SA4, SA5, SA6), where dispenser is connected, should be set in
accordance with a current value in current loop. Possible current values:
- switch 1 OFF, switch 2 OFF => 20 mA
- switch 1 ON, switch 2 OFF => 40 mA
- switch 1 OFF, switch 2 ON => 40 mA
- switch 1 ON, switch 2 ON => 60 mA
FIRMWARE UPDATE
GB interface converter’s firmware is constantly being improved and new versions of firmware with
improved functionality, new possibilities and fixed bugs of the previous firmware versions are proposed to
be applied. Latest version of interface converter firmware is always available for downloading for
customers.
Update of the interface converter firmware is made through a COM-port of personal computer using a
built-in updater in Pts_config.exe utility. Please read more about the Pts_config.exe utility in PTS controller
technical guide, which can be downloaded from PTS controller web-page
http://www.technotrade.ua/fuel_pump_controller.html.
Gnd POWER
12 V DC
SUPPLY
Pts_config utility
TxD
RxD
Gnd
4th switch of
COM-port configuration DIP-
switch SA2
Personal computer GB interface converter set to position ON
Before start of firmware update it is necessary to 4th switch of configuration DIP-switch SA2 on GB interface
converter to position ON. After the firmware update process is complete it is strongly recommended to set
4th switch of configuration DIP-switch SA2 back to position OFF.
In Pts_config.exe utility leave a COM-port closed and go to tab “Firmware update”. On the opened form
select a COM-port of connected interface converter, path to a file with a new firmware and press a button
“Start update”. Firmware will start to be updated. Wait until the process is finished. In case of any errors -
restart a tool and try again.
In case if the firmware is not being updated – power off the interface converter, click to start firmware
update and power on the interface converter. At this the firmware update process should start.
NOTE! In order to prevent interface converter firmware from accidental update it is strictly recommended
to keep 4th switch of configuration DIP-switch SA2 in OFF position in any moment of time except for
firmware update needs.
WARNING! Manufacturer guarantees reliable and stable operation of products only at compliance with
below requirements. In case of absence of uninterruptible power supply or incorrect wiring of products
to it any claims to malfunction of software are not accepted.
The described products come into structure of control system (POS) for petrol station. Power supply of the
products should be done from a separate power supply with built-in filter of radio frequency interferences
and limiter of high voltage pulse interferences. Power supply should have a safety factor of 1.5.
At emergency switching off the power supply or in case of power voltage exceeding its permitted ranges
the products can switch off with loss or corruption of data and possible damage of hardware and software.
Power supply of all electronic blocks of POS and electronic pumpheads of dispensers, which are connected
through information lines, should be made from single common uninterruptible power supply source (UPS).
Connection of other devices to given UPS is strictly prohibited. UPS should be of continuous action (online)
and work with double conversion with output voltage regulation. UPS should have a safety factor of 1.5.
Filter of radio frequency interferences and limiter of high voltage pulse interferences should be used for
feeding equipment from UPS.
Supply of electronic pumpheads of dispensers should be made from the UPS unit using 3-wires scheme
with isolated neutral through dedicated two-pole breaker for each dispenser. Connection of other parts of
dispenser to UPS unit (expect electronic pumpheads) is strictly prohibited.
UPS unit should be connected to a separate three-pole socket fed through the three-wire feeder (phase,
neutral, ground wires) with insulated neutral from a dedicated circuit breaker of switchboard. Feeder
coming from the switchboard to the socket should located not closer than 0.3 meters to other feeders. The
socket should be located at a distance of not more than 1 meter away from the POS. Phase wire of the
feeder should not have any other consumer, which are sources of interferences (for example motors).
For protection of POS and UPS from secondary effects of atmospheric electricity it is required to install
high-voltage arresters (dischargers) at the transformer substation or on poles of power lines.
2. Requirements to grounding
In the switchboard the ground wire of feeder socket should be connected to the grounding screw, which
should be connected by means of welding with a protection grounding circuit of petrol station by steel wire
with a diameter of not less than 5 mm.
Protection grounding circuit of petrol station should correspond to safety requirements and be separated
from the station lightning protection circuit. Distance from the nearest electrode of protection grounding
circuit to electrode of lightning protection circuit must be at least 10 meters. Resistance of the protection
grounding circuit should be not more than 4 Ohms and must be confirmed by the test report. Length of
wires from the switchboard to the nearest electrode of protection grounding circuit should not exceed 15
meters.
Laying of power and information wires to dispensers should be done in separate pipes with distance of not
less than 0.3 meters between each other. For informational wires (current loops, RS-485, other interfaces)
it is recommended to use shielded twisted-pair cables (recommended type – FTP CAT 5E). The cable shield
must be connected to the ground connector on one side only – on the side of the dispenser.
Connection of ATG probes installed inside the tanks should be done only with provision of required safety
measures: in case if probes have explosion-proof protection – then armored cables should be used, in case
if probes have intrinsic safety – then connection should be performed through suitable safety barriers.
- +
- +
+ -
+ -
Gilbarco Highline / Dimension Assy dispenser board Gilbarco Endeavor dispenser board
+ -
(pins 23 and 24 of port P101)
+ -
+ - dispenser board
Gilbarco Endeavor
Gilbarco 3202 series dispenser board
- +
- +
+ -
- +
Wayne Dresser dispenser iGEM board Wayne Dresser V387 dispenser board
- +
- +
- +
S4 computer
- +
IntBox
Petposan-Beta CPU
- +
- +
+
-
+
-
ORDER INFORMATION
Variant of GB-4 interface converter supply is marked with GB4-y-z, where
- y – type of supply:
o “PCB” in case if GB-4 interface converter is supplied in a view of electric board;
o “BOX” in case if GB-4 interface converter is supplied installed in mounting box with hermetic
inputs for connection of wires and a button for power supply switching;
- z – variant of supply:
o 001 – variant of supply with installed terminal blocks for controller ports
Examples of order:
- order of GB-4 interface converter in a view of electric board: GB4-PCB-001
- order of GB-4 interface converter installed in a mounting box: GB4-BOX-001