Maglinklx
Maglinklx
Maglinklx
CONSOLE MAGLINK LX
Maglink LX rev.06 2015-07 - ENG
INDEX
REVISION INDEX........................................................................................................................................................................................................................ 2
INTRODUCTION ........................................................................................................................................................................................................................ 3
GENERAL WARNINGS .............................................................................................................................................................................................................. 3
DESCRIPTION ............................................................................................................................................................................................................................. 4
COMPATIBLE PROBES MODEL LIST ..................................................................................................................................................................................... 4
INSTALLATION ........................................................................................................................................................................................................................... 5
MAIN COMPONENTS .............................................................................................................................................................................................................. 6
PROBES CONNECTIONS ......................................................................................................................................................................................................... 8
MAGLINK LX SLAVE CONNECTORS ..................................................................................................................................................................................... 9
CONSOLE VIA RS232 HOST CONNECTION ..................................................................................................................................................................... 10
MANAGEMENT SYSTEMS COMMON CONNECTION ..................................................................................................................................................... 11
PROGRAM DESCRIPTION...................................................................................................................................................................................................... 12
MANUAL UPDATE PROCEDURE .......................................................................................................................................................................................... 18
SEND LOG INFORMATION FOR SUPPORT ....................................................................................................................................................................... 18
STOCK PRINTOUT ................................................................................................................................................................................................................... 19
SHIFT REPORT .......................................................................................................................................................................................................................... 19
EXTERNAL DISCONNECTION EQUIPMENT ...................................................................................................................................................................... 20
SAFETY INSTRUCTIONS ......................................................................................................................................................................................................... 20
PRODUCT LABEL ..................................................................................................................................................................................................................... 21
CERTIFICATION........................................................................................................................................................................................................................ 22
NOTIFICATION......................................................................................................................................................................................................................... 26
REVISION INDEX
2
Maglink LX rev.06 2015-07 - ENG
INTRODUCTION
The handbook gives all the instructions for installation and use of Maglink LX console.
GENERAL WARNINGS
Please read carefully the instructions given in this handbook before working on this equipment.
The manufacture is not responsible of any operation performed not mentioned in this handbook.
In case of failure or faulty operations, please refer to authorized people in charge for maintenance or directly to the manufacturer.
The manufacturer refuses all responsibility for any eventual injury and/or damage to things caused by the missing observation of safety
requirements.
The assigned personnel is required to know all the safety requirements relative to this equipment.
In case of doubts about functioning of the equipment please refer to authorized people for maintenance or directly to the manufacturer.
Every tampering of the equipment relieves the manufacturer from any responsibility in front of competent authorities.
This product is used in fuel tanks and in hazardous areas for risk of explosion and fire. Subterranean leakage of fuel tanks may cause serious damages to
environment and people injury.
Improper use, not in accordance with the requirements, may affect the safety of the product
Note: Start Italiana Srl, in respect of its quality duties may modify its production and the data shown on this handbook. This manual cannot be
reproduced, totally and neither partially, without authorization.
3
Maglink LX rev.06 2015-07 - ENG
DESCRIPTION
Console for monitoring level gauge and tanks alarms. Bus management up to 32 probes, 16 ON-OFF sensors, 4 slave displays, 2 channel each, 4
integrated relays and other 16 relays on the bus with outputs and programmable events, 20 relays in total. Can be interfaced with the major
management systems located in petrol stations.
Main features
Consumption 15 VA
Number of probes 32
Enclosure Plastic
Protection IP20
Dimensions 265x190x95 mm
Probes output power supply 12Vdc, 100mA for each probe output, MR3 and MR4 connectors
4
Maglink LX rev.06 2015-07 - ENG
INSTALLATION
If mixed with air, the flammable vapors may cause explosion. Hazardous areas may be originated therefore by the presence of gas or vapors.
Explosions or fires may cause damage, even lethal.
This console is not explosion proof.
Do not install the console in hazardous area.
Use only fuse 250V – 1A on input power supply
INSTALLATION SITE
Regarding the installation site, it is necessary to consider that the console must be protected against vibrations and extreme climatic conditions (in
particular high/low temperatures, humidity, etc.) which may damage the electrical circuits. Please be sure to install in an area protected from humidity
and sprinkles of water.
INSTALLATION PROCEDURE
Fix the console to the wall using the holes on the plastic enclosure. To fix the console to the wall use bolt sleeves.
Bottom side.
PRODUCT CLEANING
For product cleaning must be used a cloth dampened only with water and common detergents non aggressive without use of any acids, chemical
solvents or organic substances.
5
Maglink LX rev.06 2015-07 - ENG
MAIN COMPONENTS
6
Maglink LX rev.06 2015-07 - ENG
MR3 MR4
JH3 RED (+12volt) JH3 RED (+12volt)
JH1 BROWN (RS485A) JH1 BROWN (RS485A)
JH2 BLUE (RS485B) JH2 BLUE (RS485B)
JH10 WHITE (-0 volt) JH10 WHITE (-0 volt)
MR1 connection to CN7 (Main Board Connection)
7
Maglink LX rev.06 2015-07 - ENG
PROBES CONNECTIONS
8
Maglink LX rev.06 2015-07 - ENG
9
Maglink LX rev.06 2015-07 - ENG
USB
RJ45 used to connect MagLink LX to local network for web access configuration (WebConfig). If you connect directly to other computer remember
to use a cross cable.
RS232 PORT 2
10
Maglink LX rev.06 2015-07 - ENG
ES:
CONSOLE SYSTEM
PIN 2 > PIN 2
PIN 3 > PIN 3
PIN 5 > PIN 5
CONSOLE SYSTEM
PIN 2 > PIN 2
PIN 3 > PIN 3
PIN 5 > PIN 5
PIN 4 > PIN 6
----------------------------------------------------------------------------------------------------------------------------
GILBARCO Passport Europe (9600 O71):
CONSOLE SYSTEM
PIN 2 > PIN 8
PIN 3 > PIN 1
PIN 5 > PIN 4
11
Maglink LX rev.06 2015-07 - ENG
PROGRAM DESCRIPTION
The console is provided with a Qt application that handles all fundamental values for optimal tank management.
The application is very easy and user friendly. It has a sort of circular menu from which the user can navigate through all available
functions. The application first page is the following:
In this page it’s summarized all main tank information. At the very top you’ll find configured tank list. The page can contain a maximum
of 4 tanks, if you want to see other tanks you must click on the big red right/left arrow button that you find at the right/left edge of the
touch screen.
Console functions are accessible by clicking up/down red arrow button that you find near the top left corner and bottom left corner of
the touch screen. Use these up/down arrows button to navigate through all console function as shown below:
12
Maglink LX rev.06 2015-07 - ENG
Alarm log.
To acknowledge active alarms click on the ACK button to the right of the alarm table.
List fuel represents the tank, fuel, meter configuration for those who have dispensing system connected to the console.
To access detail tank information you can either click on the tank number or directly on the tank image.
13
Maglink LX rev.06 2015-07 - ENG
Detail tank view. Alarms are graphically reported beside the green level product indicator.
14
Maglink LX rev.06 2015-07 - ENG
History list
Delivery list
15
Maglink LX rev.06 2015-07 - ENG
Diagnostic page
16
Maglink LX rev.06 2015-07 - ENG
Fuel list is the configuration between tanks and dispensers and noozles.
17
Maglink LX rev.06 2015-07 - ENG
To update the console application and the web application follow the steps:
Download the zip file with the latest version
Take an usb pen drive with at least 50MB of free space
BE SURE THE USB PEN DRIVE IS FAT32 FORMATTED
From usb pen drive create from root lx-update folder
Connect the usb pen drive to the computer and unzip the content of the downloaded file in to newly created folder lx-update
Connect the usb pen drive to the console
Click on the Info button to access info page
Wait until Usb download button appears and press the button to copy all updated files to the console newversion folder
Now press Update button to complete update procedure
Most of the times the console will reboot nor the application will be reloaded
When internet connection is not available for any reason user must provide to StartItaliana all information needed for debug process.
This is done by pressing Info button to access info page then follow the steps:
Take an usb pen drive with at least 50MB of free space
BE SURE THE USB PEN DRIVE IS FAT32 FORMATTED
Connect the usb pen drive to the console
Click on the Info button to access info page
Wait until Export log button appears and press the button to start copy process, all required files will be copied to the console
lx-support folder
Zip the lx-support folder content and email it to support@startitaliana.it
18
Maglink LX rev.06 2015-07 - ENG
STOCK PRINTOUT
Console can be provided with Sprint printer that must be connected to RS232 com1 serial port. When the printer is connected user can
print current stock, this means total product for each tank, summary product stock group by product type.
To proceed with the printout, click on Info button to access the info page and then click on Print situation button, wait until the ticket
printer comes out.
SHIFT REPORT
Console can manage shift reports. To open/close shifts just follow the instructions below.
To proceed with the shift report, click on Info button to access the info page and then click on Set shift report button and confirm the
following message box. This operation will close current shift and open next one.
19
Maglink LX rev.06 2015-07 - ENG
You can navigate through the tank dedicated pages and view the daily shift report:
SAFETY INSTRUCTIONS
“Safety Instruction” attached.
20
Maglink LX rev.06 2015-07 - ENG
PRODUCT LABEL
21
Maglink LX rev.06 2015-07 - ENG
CERTIFICATION
22
Maglink LX rev.06 2015-07 - ENG
23
Maglink LX rev.06 2015-07 - ENG
24
Maglink LX rev.06 2015-07 - ENG
25
Maglink LX rev.06 2015-07 - ENG
NOTIFICATION
26
Maglink LX rev.06 2015-07 - ENG
27
Maglink LX rev.06 2015-07 - ENG
28