Monoblock rotary cup

SKVJ(G)

Capacity range
0.45 - 6.60 MW

Fuels
Heavy oil SKVJ
Heavy oil / gas SKVJG

Application fields, especially in the industrial heat marketFlame tube boilers, three pass
boilers, heat radiation boilers, thermal oil boilers
Advantages

• Highest quality standard by latest state of production and engineering, application of ISO
9001 quality management system
• Environment-friendly due to low NOx technology and lowest emission values
© Jan 2008 · SAACKE GmbH · All rights reserved. Content subject to alteration

• Suitable for liquid and gaseous fuels of different quality


• Standardised monoblock construction with integrated wind box, air distribution device and
combustion air fan
• High modulating range
• Economic due to optimal combustion and lost costs for energy, investment, maintenance,
and service
• Economic due to minimised standstill losses and a long service life

SAACKE GmbH · Südweststrasse 13 · 28237 Bremen · Germany


Phone: +49 - 421- 64 95 0 · Fax: +49 - 421- 64 95 224 · E-Mail: info@saacke.de · www.saacke.com
Where the combustion of liquid and gaseous fuels makes high demands on economy, operational
reliability, control range, and environmental consciousness, SAACKE rotary cup atomising
burners are the first choice. Environment-conscious and economic use of the energy that is made
available to us by nature - that is what SAACKEs rotary atomising technology makes
successfully possible.

The SAACKE rotary cup atomiser SKV(G) is a low NOx burner that combines all advantages of
the rotary cup atomising principle with low-costs, short supply times and simple assembly over the
complete control range. The SKVJ(G) is available in monoblock design i.e. the fan is integrated
into the burner. Decades of experience in handling difficult fuels ensure that even the standard
burner types have the lowest emission values compared with other firing plants that have been
launched to the market.
Being specially adapted for flame tube boilers, the robust and compact burner offers all
advantages of a complete system including an integrated silencer (sound absorber) for low-noise
operation. The SKVJ(G) burner has been designed for low-emission combustion and low
unburned solids content in exhaust air. Due to the modular construction, the SKVJ(G) can easily
be retrofitted or equipped with a water-fuel oil mixing unit whereby combustion even can be
optimised. This solution is especially suitable when heavy oil with high asphalt content is used.
Moreover, the SKVJ oil burner can be easily retrofitted at any time with a gas ring, thus being
converted to a dual-fuel burner type for the purpose of burning gas as well as fuel oil.
© Jan 2008 · SAACKE GmbH · All rights reserved. Content subject to alteration

SAACKE GmbH · Südweststrasse 13 · 28237 Bremen · Germany


Phone: +49 - 421- 64 95 0 · Fax: +49 - 421- 64 95 224 · E-Mail: info@saacke.de · www.saacke.com
© Jan 2008 · SAACKE GmbH · All rights reserved. Content subject to alteration

SAACKE GmbH · Südweststrasse 13 · 28237 Bremen · Germany


Phone: +49 - 421- 64 95 0 · Fax: +49 - 421- 64 95 224 · E-Mail: info@saacke.de · www.saacke.com
Maße / Dimensions (mm)
Brennertyp
A B C D E
Burner type
SKVJ(G) 10 374 375 829 572 579
SKVJ(G) 15 404 375 829 572 579
SKVJ(G) 25 505 375 882 624 541
© Jan 2008 · SAACKE GmbH · All rights reserved. Content subject to alteration

SAACKE GmbH · Südweststrasse 13 · 28237 Bremen · Germany


Phone: +49 - 421- 64 95 0 · Fax: +49 - 421- 64 95 224 · E-Mail: info@saacke.de · www.saacke.com
Brennstoff Leistung 0.45 0.45 0.55 0.48 0.48 0.59 0.59 0.68
Fuel Capacity
ca. (MW) 1.13 1.9 2.8 3.15 3.86 5.05 6.18 6.6
Brennertyp
10 15 25 20 30 40 50 55
Burner type
Schweröl
SKVJ
Heavy oil
Schweröl/Gas
SKVJG
Heavy oil/gas

Equipment

• Rotary cup atomiser with integrated primary air fan


• Electronic or mechanical compound regulator
• Integrated combustion air fan with suction sound absorber
• Flame detection controlled by micro processor
• Air guiding housing with control damper
• Bearing and air guiding housing with control damper
• Gas-electric or oil-electric ignition device
• Gas mixing unit (gas operation)
• Gas valve train (gas operation)
• Fuel oil valve train (oil operation)
• 2 safety shut-off valves for fuel oil (oil operation)
• Options like O2 control, frequency-controlled combustion air fan, water injection for reducing
the content of solids
• All burner components are pre-assembled, pre-wired, and prepared for external connection
© Jan 2008 · SAACKE GmbH · All rights reserved. Content subject to alteration

SAACKE GmbH · Südweststrasse 13 · 28237 Bremen · Germany


Phone: +49 - 421- 64 95 0 · Fax: +49 - 421- 64 95 224 · E-Mail: info@saacke.de · www.saacke.com