Architectural Interiors - Architectural Interior Standards
Architectural Interiors - Architectural Interior Standards
Architectural Interiors - Architectural Interior Standards
ARCHITECTURAL
INTERIOR
STANDARDS
SUBMITTED BY:
BACOLOR, LYANNA AVRIL M.
CALDITO, BERNADETH B.
CAYABYAB, JEZRAEL S.
LIPAE, PAULINE O.
SADIA, DANIELLE THERESE A.
SUBMITTED TO:
AR. GABRIELLE LOIS M. BENEDICTOS, UAP
DATE:
JANUARY 29, 2024
REFERENCES:
P.D. 1096, BP 344, RA 9514
COLEGIO DE MUNTINLUPA
Mayor J.Posadas Ave, Sucat, Muntinlupa,
1770 Metro Manila
Department of Architecture
Architectural Interiors
Instructor:
Ar. Gabrielle Lois M. Benedictos, UAP
References:
Section 707- Maximum Height Slip Resistant Materials Section 10.2.5.2, para-F & N -
- Flooring must be slip- Means of Egress
- more than 3.00 meters resistant - [F.] Minimum width: 915
a. Walkways/ Passageways mm
b. Corridors: turnabouts - [N.] Minimum
c. Stairs: thread surfaces, headroom:
nosing
- COF (coefficient of friction)
for level surfaces: 0.6
- COF (coefficient of friction)
for sloping surfaces: 0.8
Section 708- Stairs Section 03, appx. A – Walkways Section 10.2.5.4, para-B, G –
and Passageways Stairs
- at least 750 millimeters in - 3.4 Minimum width of
clear width, with a rise of 200 walkways: 1.20 m - [G.2] Load capacity: 488
millimeters and a minimum kg/m2 / 136 kg
run of 200 millimeters. - [G.3] Maximum width of
treads and height of
risers: 5 mm (except as
allowed for monumental
stairs)
- [G.4] Treads less than
250 mm must have a
nosing or project about
25 mm over the level
COLEGIO DE MUNTINLUPA
Mayor J.Posadas Ave, Sucat, Muntinlupa,
1770 Metro Manila
Department of Architecture
Architectural Interiors
Instructor:
Ar. Gabrielle Lois M. Benedictos, UAP
below.
Section 805- Ceiling Heights Section 04, appx. A – Handrails Section 10.2.5.4, para-H –
- Rooms with artificial - Handrail height: 0.90 m or Handrails
ventilation: 0.70 m above steps or
a. First storey: 2.70 meters ramps - [H.4.a] Height: between
- Installation of handrails for 760 mm and 865 mm
protection at greater (measured vertically
heights: 1.0 m to 1.06 m. from a point 25 mm back
- Handrail extensions at from the leading edge of
stair/ramp beginnings and the tread)
ends: 30 cm - [H.4.b] Minimum
a. diameters between 30 mm clearance: 38 mm from
and 50 mm for a secure the wall
grasp, - [H.4.b] Load capacity: at
- Clearance: 50 mm from least 91 kg
walls and 40 mm from
ledges.
Section 806- Size and Dimension of Section 03, appx. C – Doors Section 10.2.5.3, para-E & F –
Rooms: - Minimum clear width of Doors
- Rooms for Human each door: 900 mm
Habitation: – 6.00 square a. the clear openings should - (E.1) Minimum door
meters with a least dimension be measured from the fully openings in clear width:
of 2.00 meters open door, positioned at a 710 mm
right angle (90°) to the door - (E.2) Maximum doorway
jamb. width: 1.22 m
- Minimum level area before - (E.3) Maximum height of
and beyond a door: 1.50 m thresholds at doorways:
× 1.50 m 13 mm
a. EXCEPTION: If a door - (E.3) Floor surfaces on
opens into but does not both sides of a door must
enter a corridor, the not differ by more than
COLEGIO DE MUNTINLUPA
Mayor J.Posadas Ave, Sucat, Muntinlupa,
1770 Metro Manila
Department of Architecture
Architectural Interiors
Instructor:
Ar. Gabrielle Lois M. Benedictos, UAP
Section 807- Air Space Requirements Section 04, appx. C – Thresholds Section 10.2.5.10, para-A.3 &
in Determining the Size of Rooms: - Maximum height of A.6.B – Fire Escape Stairs
- School Rooms: 3.00 cubic threshold and sliding door
meters with 1.00 square meter tracks: 25 mm, preferably - [A. 3] Minimum widths:
of floor area per person 600 mm clear between
ramped.
- Workshops, Factories, and rails
- Minimum horizontal
COLEGIO DE MUNTINLUPA
Mayor J.Posadas Ave, Sucat, Muntinlupa,
1770 Metro Manila
Department of Architecture
Architectural Interiors
Instructor:
Ar. Gabrielle Lois M. Benedictos, UAP
with no obstruction
- Minimum area of
recesses/turnabout spaces:
1.50 m x 1.50 m
- Maximum area of
recesses/turnabout spaces:
12.00 m
- Turnabout spaces: within 3.50
m. of every dead end
- Maximum height of
lavatories: 0.80
a. with a knee recess of 0.60
- 0.70m vertical clearance
b. 0.50 m. depth.
HUMAN ANTHROPOMETRICS
Female Male
Standing
- Shoulder height:1355mm
- Shoulder height:1430mm
- Shoulder width: 405mm
- Shoulder width: 460mm
- Upward reach: 1970mm
- Upward reach dimension: 2120mm
- Side reach: 820mm
- Side reach: 885mm
- Full reach finger to finger: 1650mm
- Full reach finger to finger: 1790mm
- Forward reach: 705mm
- Forward reach: 780mm
- Knuckle height: 740mm
- Knuckle height: 770mm
- Hip width: 400mm
- Hip width: 370mm
- Sitting Down
In Wheelchairs
- Forward reach (over table): 510mm - Forward reach (over table): 580mm