Nothing Special   »   [go: up one dir, main page]

Heat Exchanger 120-180KVA-2

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

HEAT EXCHANGER COOLED SERIES

( 120KVA – 180 KVA)

STANDARD SPECIFICATION

• Natural aspirated or turbocharged inline diesel engine


• Hear exchanger cooled
• 12 Volt / 24 Volt DC electrical system
• Digital controller module with monitoring and protection for oil pressure, water
temperature, engine speed, voltage, ampere and frequency
• Power switch, emergency stop button and indicator lamps
• Vibration isolators
• Brushless self excited AC marine alternator with AVR +/-1.5% regulation.
HEAT EXCHANGER COOLED SERIES
TECHNICAL DATA ( 120KVA – 180 KVA)

POWERDRIVE MARINE MODEL PDM 120E70HE PDM 140E70HE PDM 160E70HE PDM 180E70HE

1500rpm KVA 120 140 160 180

1800rpm KVA 140 160 180 200


Prime Rating (100%)
1500rpm KWE 96 112 128 144

1800rpm KWE 112 128 144 160

Governor Electronic Electronic Electronic Electronic

Starting System 12/24 V

ENGINE
Brand PERKINS PERKINS PERKINS PERKINS

Model E70 TAG1M E70 TAG2M E70 TAG3M E70 TAG3M

Number of Cylinder 6 6 6 6

Cylinder Arrangement In-line In-line In-line In-line

Bore & Stroke (mm) 105 X 135 105 X 135 105 X 135 105 X 135

Displacement 7 litres 7 litres 7 litres 7 litres

Aspiration Turbocharged Turbocharged Turbocharged Turbocharged

Compression Ratio 16:5:1 16:5:1 16:5:1 16:5:1

ALTERNATOR

Stamford UCM274 UCM274 UCM274 UCDM274K

Mecc Alte ECP34 ECP34 ECO38 ECO38

Type Brushless

Excitation Self-excited

Voltage Regulation +/- 1.5%

Alternator Bearing Single

No. of Poles 4

LENGTH WIDTH HEIGHT WEIGHT


MODEL
(mm) (mm) (mm) (kg)

PDM120E70HE 2212 1052 1950 1935

PDM140E70HE 2212 1052 1950 1935

PDM160E70HE 2320 1052 1950 2040

PDM180E70HE 2490 1052 1950 2310

Note :
• All above rating based on Prime Power Rating & available at variable load in lieu of main power network
• An overload of 10% is permitted for one hour in every twelve hours of operation
• Test conditions based on air temperature 25°C (80.6°F), barometric pressure 100 kPa (29.5 in Hg), relative humidity 30%, maximum exhaust back pressure 6
kPa, maximum inlet restriction 3 kPa
• Electrical ratings assume a power factor of 0.8 & generator efficiency of 90%
• Fuel specificaiton based on BS 2869: Part 2 1998 Class A2 or ASTM D975 D2
• Performance tolerance for the above power rating is + 5%
• Final weight and dimensions will depend on completed specification

Distributed by :

All information in this leaflet is substantially correct at the time


of printing but may be altered subsequently by the Company
Publication Number : MPD/MP/0715