User Manual
EC30 Door Controller
用户名 机器名 日期 时间
Danger: dangers arising from operating not as required may cause serious injury or even death.
Notice: dangers arising from operating not as required may cause moderate or minor injury as
well as damage to equipment.
We strongly
gly suggest that when installing, debugging and maintaining the system the users
should carefully read this chapter and strictly follow the safety precautions required in the content
of this chapter to operate. Any injury or damage caused by violation operations shall have no nothing
to do with our company.
1. Installation
Danger
Please install
all the controller onto the flame-retardant
retardant objects such as metal to avoid possible
breaking out of fire!
Please keep away from combustible articles to avoid possible breaking out of fire!
Notice
The lead head or screw is not allowed to fall into the system in order to avoid possible damage
to the controller!
Please make sure the place where the controller is installed to have little vibration and have no
direct sunshine!
Please make sure the site where the controller is installed to be strong enough to bear the
weight of the controller to avoid possible falling accident and the relevant injury!
In unpacking, if the controller is found damaged, please don't install!
In case that the packing list is not in conformity with
with the name of the real object, please don't
install!
In moving the controller, you should handle gently, or there will be possible damage to the
equipment!
Don’t touch the components of the controller with your hands, or there will be possible
electrostaticc damage to the controller!
2. Wiring
Danger
The guidance of the manual must be followed, and the constructors have to be professional
electric engineering personnel, in order to avoid electric shock and injury accident!
The controller and the power supply have to be separated by a breaker to avoid possible
用户名 机器名 日期 时间
Notice
Definitely not connect the input
inpu power supply to the output terminals (U, V, W) of the
controller. Please notice the mark of the wiring terminals so as not to connect wrongly! Or the
controller may be damaged!
Make sure the wiring circuits meet the EMC requirements and the safety standard in your
region. Or accident may occur!
The communication line must adopt the shielded twisted pair with the line space of 20~30mm
and the shielded layer being grounded!
Make sure the rated voltage of the product is consistent with the voltage of the alternat
alternating
current power supply, in order to avoid possible injury accident and possible breaking out of
fire!
Notice to check whether the peripheral circuit connecting to the controller has short circ
circuit;
whether the connected circuit is secure, otherwise the controller will be damaged!
No part of the controller needs any withstand voltage test which has been conducted when the
product leaves the factory, or accident may occur!
3. Power On
Danger
Power on is only allowed when the cover plate of the controller is covered. After power on,
don’t open the cover plate and touch any input or output terminal of the controller
controller, otherwise
possible electric shock may be caused!
The wiring of all peripheral accessories must follow the guidance of the manual, and wiring
shall be made properly according to the circuit wiring
wiring method provided in the manual
manual. Or
accident may occur!
Please don't arbitrarily change the factory parameters of the controller. Or possible damage to
the equipment may be caused!
Non-professional technical personnel are not allowed to test the signal in running of the
controller, or possible injury or possible damage to the equipment may occur!
Danger
Please don't carry out repair and maintenance for the equipment when it's electrified. Or
possible electric shock may occur!
Personnel who haven't received professional training are not allowed to carry out repair and
maintenance for the controller. Or personal injury or damage to equipment may be caused!
After replacement of controller,
controller the parameters have to be set, and all pluggable
uggable inserts have to
用户名 机器名 日期 时间
Table of Contents
1. Product Introduction ............................................................................................................................. 1
1.1. Ratings .................................................................................................................................................. 2
1.2. Operating Conditions ............................................................................................................................ 2
2. Electric debugging .............................................................................................................................. 3
2.1. Description on the Controller Interface ................................................................................................ 3
2.2. Panel Operation Instructions ................................................................................................................. 5
2.3. Basic Operation of the Buttons ............................................................................................................. 6
2.4. Wiring Diagram .................................................................................................................................... 7
2.5. Debugging Steps ................................................................................................................................... 7
2.6. Adjustment for motion curve ................................................................................................................ 9
2.6.1. Opening motion curve................................................................................................................................... 9
2.6.2. Closing motion curve .................................................................................................................................. 10
2.6.3. Door vane regulation parameters ................................................................................................................ 11
2.6.4. Motor regulation parameters ....................................................................................................................... 11
3. Description on Functional Parameters ................................................................................................ 13
3.1. Monitoring Parameter List .................................................................................................................. 13
3.2. Parameter list ...................................................................................................................................... 14
3.2.1. F0 Curve parameters ................................................................................................................................... 14
3.2.2. F1 Speed regulation parameters .................................................................................................................. 15
3.2.3. F2 Motor parameters ................................................................................................................................... 15
3.2.4. F3 Driver parameters .................................................................................................................................. 16
3.2.5. F4 Door operator parameters ...................................................................................................................... 16
3.2.6. F5 Door operator parameters ...................................................................................................................... 17
3.2.7. F8 Adjustment parameters of door operator ................................................................................................ 18
3.3. Fault listing ......................................................................................................................................... 19
用户名 机器名 日期 时间
1. Product Introduction
EC30 door controller unit is a driving system controlling permanent magnet synchronous
motor and is specified for elevator door, and it's able to achieve the best door opening and closing
speed curve, efficient, reliable, easy to operate and of small mechanical vibration; the EC30 door
operator controller is applicable to the door system whose net door opening width is (700~1500)
mm.
Its main characteristics are as follows:
Self-learning of door width;
Demonstration of automatic door opening and closing;
Failure alarm and self-protection function;
Selectable sandwich and detection function;
1
用户名 机器名 日期 时间
Input voltage Rated frequency Rated power Output voltage Output current
AC220V±15% 50/60Hz 400W 0~220V 2A
1. Altitude:
Below 1000m, 100% rated current output;
1000~2000m, 95% rated current output;
2000~3000m, 85% rated current output:
2. Relative humidity is not bigger than 90% (at 25℃);
3. Voltage: 200V~250V.50~60Hz;
4. In the ambient air, there shouldn't be corrosive and inflammable gases and conductive
dust;
2
用户名 机器名 日期 时间
2. Electric debugging
2.1. Description on the Controller Interface
3
用户名 机器名 日期 时间
4
用户名 机器名 日期 时间
Through the operation panel, the user may modify the functional parameters of the door
controller and monitor the operating state of the controller.
1. Description on buttons of the operation panel
Button Description
Programming key, for entering or exiting the first
MODE
class menu and for deleting the shortcut parameters.
Confirmation key, for gradually entering the menu
SET
screen and for confirmation of setting of parameters.
Ascending key, for ascending of the data or function
code.
Decreasing key, for decreasing of the data or
function code.
Operation key, for the controller to execute
RUN
corresponding run command.
In running state, press the key may stop the running
STOP
operation.
2. Dial switch function description
Dial 1 state Dial 2 Function Function description
state
ON ON Normal The door operator enters into the state to normally
receive the door opening and closing commands
ON OFF Demonstration The door operator enters into the demonstration running
state, and press RUN key will start the demonstration
running
OFF ON Learning The door operator enters into the running state to learn
the door width, and press the RUN key will start
learning the door width
OFF OFF Positioning The door operator enters into the running state to
position the motor, and press the RUN key will start
learning the angle of the motor.
5
用户名 机器名 日期 时间
6
用户名 机器名 日期 时间
7
用户名 机器名 日期 时间
Not
.. .ice
... : The
.. . modified
.. .. ......parameter
.. ... ...can
... not
.. .be
.
..written
....... when
....the
...motor
.
....movement,
........
ple
... ase
....turn
.. .. the
...dial
....to
..the
. positioning
... ..........state
.....to modify
.... ....the
. parameters
... .... ....
8
用户名 机器名 日期 时间
Velocity changing when door operator opening: the door operator accelerate to F0 F0-07(starting
speed),when opening command take effect. The door operator accelerate to F0 F0-11(maximum
allowable speed),till the door position reached to F0 F0-08(starting
08(starting low speed distance).After a
period of time ,beginn to slow down to F0-09(open
F0 09(open to get to speed).The door operator creeping
motion
otion with velocity of open to get to low speed ,after the door position reached to F0
F0-10(open to
get to low speed distance).And into the holding state ,the value of torque is F4-02(opening
02(opening hold
torque).
Acceleration changing when door operator
oper opening: Thee acceleration gradually increase,
when the door position reached to F0 F0-08(starting
08(starting low speed distance).The acceleration jerk is
F0-03.Eventually,the
03.Eventually,the acceleration reached to F0 F0-12(maximum
12(maximum allowable acceleration).The
acceleration decreases gradually until iit reaches zero, when the velocity will be reached to
F0-11(maximum
11(maximum allowable speed).The acceleration is F0-04.The
F0 04.The speed will slow down after a
period of time. The deceleration jerk is F0-05.Eventually
F0 05.Eventually the deceleration reached to
F0-13(maximum allowable deceleration).The
eleration).The deceleration changed to F0-06(deceleration
F0 06(deceleration jerk 2),
when the velocity will be reached to F0-09(open
F0 to get to speed)
The maximum allowable speed and maximum allowableallowable acceleration already has been
determined in general .The speed controlled
ontrolled by four acceleration jerk.. Sometimes the door width
is too narrow to complete action of the door operator , so it can’tt reached to the maximum
allowable speed and maximum allowable acceleration. The motion curve as shown in the
following figure.
用户名 机器名 日期 时间
Velocity changing when door operator opening:: the door operator accelerate to
F0-18(starting speed),when opening command take effect. The door operator accelerate to
F0-22(maximum
(maximum allowable speed),till the door position reached to F0-19(starting
F ing low speed
distance).After a period of time ,begin to slow down to F0-20(close
F to get to speed).
speed).Though
parameters F0-25(unlocking
25(unlocking distance of synchronous door vane) and F0-27(speed
27(speed of closing door
vane) to set the working of door vane
vane. The door operator into the holding state when it completed
comp .
The value of torque is F4-05(closing
ing hold torque).
Acceleration changing when door operator opening: The acceleration gradually increase,
when the door position reached to F0 F0-19(starting low speeded distance).The acceleration jerk is
F0-14.Eventually,the
14.Eventually,the acceleration reached to F0 F0-23(maximum
23(maximum allowable acceleration).The
acceleration decreases gradually until it reaches zero, when the velocity
velocity will be reached to
F0-22(maximum allowable speed).The The acceleration
acc is F0-15.The
.The speed will slow down after a
period of time. The deceleration jerk is F0-16.Eventually
F0 .Eventually the deceleration reached to
F0-24(maximum
(maximum allowable deceleration).The deceleration
deceler changed to F0-17(deceleration
(deceleration jerk 2),
when the velocity will bee reached to F0-20(close
F0 to get to speed)
用户名 机器名 日期 时间
Modifying the parameters F0-2828(Types of door vane)in order to make different types of
door operator functional . Corresponding parameter 0: Asynchronous,;1: Synchronous
Linkage parameters will change if you modifying this parameter .The
The linkage parameters as
the following table.
Code Description Asynchronous Synchronous Unit
Running direction selection of motor 0 1 1
F0-01 0: forward
1: reverse
F0-08 Opening curve: starting low speed distance 22 10 mm
F0-21 Closing curve: close to get to low speed distance 25 15 mm
F0-25 Unlocking distance of synchronous door vane 0 45 mm
Close hole toque at thee outside of the cclose to reach 1 0 1
the error scope
F4-24
0: no hold torque
1: have hold torque
12