Main
Range of product Harmony Safety Automation
Safety level Can reach PL e/category 4 for normally open relay contact conforming to ISO 13849-1
Can reach SILCL 3 for normally open relay contact conforming to IEC 62061
Can reach SIL 3 for normally open relay contact conforming to IEC 61508
Can reach PL c/category 1 for normally closed relay contact conforming to ISO 13849-1
Can reach SILCL 1 for normally closed relay contact conforming to IEC 62061
Can reach SIL 1 for normally closed relay contact conforming to IEC 61508
Connections - terminals Removable screw terminal block, 0.2...2.5 mm² solid or flexible
Removable screw terminal block, 0.25...2.5 mm² flexible with ferrule single conductor
Removable screw terminal block, 0.2...1.5 mm² solid or flexible twin conductor
Removable screw terminal block, 2 x 0.25...1 mm² flexible with ferrule without cable end, with bezel
Removable screw terminal block, 2 x 0.5...1.5 mm² flexible with ferrule with cable end, with bezel
Complementary
Synchronisation time between 0.5 s
inputs 2s
14/11/2023 1
4s
Power consumption in W 3 W 24 V DC
[Ie] rated operational current 5 A AC-1 for normally open relay contact
3 A AC-15 for normally open relay contact
5 A DC-1 for normally open relay contact
3 A DC-13 for normally open relay contact
3 A AC-1 for normally closed relay contact
1 A AC-15 for normally closed relay contact
3 A DC-1 for normally closed relay contact
1 A DC-13 for normally closed relay contact
Associated fuse rating 10 A gG for NO relay output circuit conforming to IEC 60947-1
[Ui] rated insulation voltage 250 V (pollution degree 2) conforming to EN/IEC 60947-1
Depth 120 mm
Height 100 mm
Width 45 mm
Environment
Standards IEC 60947-5-1
IEC 61508-1 functional safety standard
IEC 61508-2 functional safety standard
IEC 61508-3 functional safety standard
IEC 61508-4 functional safety standard
IEC 61508-5 functional safety standard
IEC 61508-6 functional safety standard
IEC 61508-7 functional safety standard
ISO 13849-1 functional safety standard
IEC 62061 functional safety standard
2
14/11/2023
IP40 (housing) conforming to EN/IEC 60947-1
IP20 (terminals) conforming to EN/IEC 60947-1
Packing Units
Unit Type of Package 1 PCE
Offer Sustainability
Sustainable offer status Green Premium product
WEEE The product must be disposed on European Union markets following specific waste collection and
never end up in rubbish bins
14/11/2023 3
Product datasheet XPSUAT13A3AP
Dimensions Drawings
Dimensions
4
14/11/2023
Product datasheet XPSUAT13A3AP
Mounting and Clearance
14/11/2023 5
Product datasheet XPSUAT13A3AP
Mounting and Clearance
Screw-mounting
6
14/11/2023
Product datasheet XPSUAT13A3AP
Connections and Schema
Wiring Drawing
Recommended replacement(s)