Nothing Special   »   [go: up one dir, main page]

Click Here To The Previous Page

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

1/4/22, 11:47 AM VERSION I98191A08

Click here to the previous page.

Error
Message Coil Item
Code

EX0908 Parts catcher out command has been given


PARTS CATCHER NOT without in finish position. Parts catcher in
PER0908
HOME POSITION command has been given without out finish
position.
EX0910 PLEASE CLOSED THE A parts cather OUT command has been given
PER0910
DOOR while the door is not closed.
EX0913 An auto presetter arm down command has been
SPINDLE OR ROTARY
PER0913 given during spindle or rotary tool spindle
TOOL SPINDLE ON
rotation.
EX0914 TOOL PRESETTER ARM The parts catcher OUT command has been
PER0914
DOWN given while the presetter arm does not rise.
EX0915 AXIS NEED ZERO An auto presetter arm down command has been
PER0915
RETURN given while axis is not at the zero point.
EX0916 Auto presetter arm down, auto door open/close,
PARTS CATCHER NOT tailstock unclamp command has been given
PER0916
HOME POSITION while the parts catcher is not in the home
position.
EX0922 Bar feeder command has been given during
CHUCK IS CLAMPED PER0922
chuck clamped.
EX0923 TOOL PRESETTER An auto presetter arm rise command has been
PER0923
SENSOR ON given while the sensor is ON.
EX0930 Alarm in special design. Refer to the
OPTION ALARM 1 TER0930
accompanying documents for the special design.
EX0931 Alarm in special design. Refer to the
OPTION ALARM 2 TER0931
accompanying documents for the special design.
EX0932 Alarm in special design. Refer to the
OPTION ALARM 3 TER0932
accompanying documents for the special design.
EX0933 Alarm in special design. Refer to the
OPTION ALARM 4 TER0933
accompanying documents for the special design.
EX0934 Alarm in special design. Refer to the
OPTION ALARM 5 TER0934
accompanying documents for the special design.
EX0935 Alarm in special design. Refer to the
OPTION ALARM 6 TER0935
accompanying documents for the special design.
EX0936 Alarm in special design. Refer to the
OPTION ALARM 7 TER0936
accompanying documents for the special design.
EX0937 Alarm in special design. Refer to the
OPTION ALARM 8 TER0937
accompanying documents for the special design.
EX0945 ROBOT/LOADER ROBOT/LOADER command has been given
PER0945
COMMAND ERROR while the machine is not in home position.
EX0946 ROBOT/LOADER ARM PER0946 T-code, coolant on, auto presetter arm down,

file:///D:/DOCUMENT/DURA HELP/Lang00/EXHLP002.htm 1/4


1/4/22, 11:47 AM VERSION I98191A08

IN spindle forward/reverse, rotary tool spindle


forward/reverse. Rotary tool connection check
command has been given while robot/loader arm
is moving in.
EX0951 TOOL PRESETTER The sensor has been activated without setting
MER0951
SENSOR ON the presetter mode.
EX0952 TOOL PRESETTER The sensor has been activated with the presetter
MER0952
SENSOR ON arm rising.
EX0953 ROOL PRS. ARM DOWN The presetter arm rise detection signal has been
MER0953
IN AUTO MODE deactivated during automatic mode.
EX0956 TWO OR MORE
Two sensors or more have been activated during
SENSORS ON SAME MER0956
presetter mode.
TIME
EX0959 BAR FEEDER EMG. The bar feeder alarm signal has been sent from
MER0959
STOP SIGNAL ON bar feeder.
EX0962 ROBOT/LOADER ROBOT/LOADER cycle has been completed in
MER0962
CYCLE TIME OVER the specified time.
EX0964 MATERIAL IN
On models equipped with a robot/loader,
ROBOT/LOADER MER0964
workpieces have run out.
EMPTY
EX0966 ROBOT/LOADER
MER0966 The robot/loader alarm has been output.
ALARM SIGNAL ON
EX0968 On the model equipped with one piece bar
BAR IN STOCK EMPTY MER0968
feeder, bar stock has run out.
EX0979 The chuck clamp opertion has not been
WORK SEATING
MER0979 completed within the specified time when
SIGNAL TIME OVER
workpiece holding direction specification.
EX0980 Alarm in special design. Refer to the
OPTION ALARM 21 TER0980
accompanying documents for the special design.
EX0981 Alarm in special design. Refer to the
OPTION ALARM 22 TER0981
accompanying documents for the special design.
EX0982 Alarm in special design. Refer to the
OPTION ALARM 23 TER0982
accompanying documents for the special design.
EX0983 Alarm in special design. Refer to the
OPTION ALARM 24 TER0983
accompanying documents for the special design.
EX0984 Alarm in special design. Refer to the
OPTION ALARM 25 TER0984
accompanying documents for the special design.
EX0985 Alarm in special design. Refer to the
OPTION ALARM 26 TER0985
accompanying documents for the special design.
EX0986 Alarm in special design. Refer to the
OPTION ALARM 27 TER0986
accompanying documents for the special design.
EX0987 Alarm in special design. Refer to the
OPTION ALARM 28 TER0987
accompanying documents for the special design.
EX0999 SEQUENCE PROGRAM MER0999 Abnormality in sequence program. Contact Mori

file:///D:/DOCUMENT/DURA HELP/Lang00/EXHLP002.htm 2/4


1/4/22, 11:47 AM VERSION I98191A08

ABNORMAL Seiki.
EX1005 A cycle start has been activated when the bar
PLEASE SUPPLY THE
PER1005 stock runs out. Put the new stock. (one piece bar
NEW MATERIAL
feeder)
EX1024 The door has never been opened after executing
PLEASE OPEN THE
PER1024 M02 or M30 command. Open and close the door
DOOR ONCE
before atarting new cycle.
EX1030 ROTARY TOOL
PER1030 Rotary tool spindle is overloaded. #2
SPINDLE OVERLOAD #2
EX1033 ROTARY TOOL
Rotary tool spindle is overloaded warning level.
SPINDLE LOAD MER1033
#2
WARNING #2
EX1034 POWER MUST BE OFF PER1034 After turning off the power once, turn it on again.
EX1035 LOAD MONITOR Parameter for load monitor function is improperly
PER1035
PARAMETER ERROR set.
EX1036 ALARM AT TEACHING
PER1036 Alarm occurs during teaching mode.
MODE
EX1037 SPINDLE OVERLOAD PER1037 Spindle is overloaded.
EX1038 X-AXIS OVERLOAD PER1038 X-axis is overloaded.
EX1039 Y-AXIS OVERLOAD PER1039 Y-axis is overloaded.
EX1040 Z-AXIS OVERLOAD PER1040 Z-axis is overloaded.
EX1041 SPINDLE OVERLOAD #2 PER1041 Sub spindle is overloaded.
EX1042 X-AXIS OVERLOAD PER1042 X-axis is overloaded.#2
EX1043 Z-AXIS OVERLOAD PER1043 Z-axis is overloaded.#2
EX1046 ROTARY TOOL
PER1046 Rotary tool spindle is overloaded.
SPINDLE OVERLOAD
EX1047 SPECIFIED PC Parameter for machine specification is
PER1047
PARAMETER CLEARED improperly set.
EX1050 SPINDLE LOAD
MER1050 Spindle is overloaded warning level.
WARNING
EX1051 X-AXIS LOAD WARNING MER1051 X-axis is overloaded warning level.
EX1052 Y-AXIS LOAD WARNING MER1052 Y-axis is overloaded warning level.
EX1053 Z-AXIS LOAD WARNING MER1053 Z-axis is overloaded warning level.
EX1054 SPINDLE LOAD
MER1054 Sub spindle is overloaded warning level.
WARNING #2
EX1055 X-AXIS LOAD WARNING
MER1055 X-axis is overloaded warning level #2.
#2
EX1056 Z-AXIS LOAD WARNING
MER1056 Z-axis is overloaded warning level #2.
#2
EX1057 ROTARY TOOL
SPINDLE LOAD MER1057 Rotary tool spindle is overloaded warning level.
WARNING
file:///D:/DOCUMENT/DURA HELP/Lang00/EXHLP002.htm 3/4
1/4/22, 11:47 AM VERSION I98191A08

EX1058 C-AXIS LOAD WARNING MER1058 C-axis is overloaded warning level.


EX1061 Spindle & servo motor shut off check signal error
(time over). ・shut off check signal is ON though
MER0956 power is not OFF at power supply. ・shut off
MOTOR INTERRUPTION
IS ABNORMAL check signal is OFF though power is OFF at
power supply. ・shut off check signal is OFF
though power is OFF at normal operation.
EX1064 WORK NUMBER
MER1064 Work number search signal is disconnected.
PARITY ERROR
EX1067 AUTO DOOR IS
MER1067 Auto door close detection signal has turned off.
OPENED
EX1068 AUTO DOOR
Auto door open or close detection signal has not
OPEN/CLOSE TIME MER1068
been turned on within the specified time.
OVER
EX1079 The one of following commands has not been
completed within the specified time.(Commands
spindle 1,2 and chuck 1,2 spindle rotation or
orientation, spindle stop, phase or speed
synchronous ON/OFF, rotary tool spindle rotation
COMMAND TIME OVER MER1079 or orientation, chuck clamp/unclamp, C-axis
connection, C-axis rerease, spindle brake
clamp/unclamp, work unload, tailstock spindle
IN/OUT, automatic tool presetter arm UP/DOWN,
work unloader IN/OUT, ceiling shutter
open/close, forkardt chuck index)
EX1080 X,Y-AXIS NEED ZERO
MER1080 Manually return X,Y-axis to the zero point.
RETURN
EX1084 Manual door close detection signal has turned
DOOR IS OPENED MER1084
off.
EX1300 Atailstock out/in command, or tailstock
TOOL PRESETTER ARM
PER1300 forward/unclamp command has been given with
DOWN
the presetter arm not fully raised.
EX1301 A tailstock out/in command, or auto tool presetter
TAILSTOCK IS
PER1301 down command has been given with the tailstock
UNCLAMPED
unclamped.
EX1302 A tailstock out/in/unclamp command, steady rest
open/close command, or tailstock
TURRET ROTATING PER1302
forward/backward command has been given
during turret indexing.

Click here to the next page.

file:///D:/DOCUMENT/DURA HELP/Lang00/EXHLP002.htm 4/4

You might also like