HE-MRUT-001

Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

Report No.

: HE-MRUT-001/23 Page 1 of 3
MEDIUM RANGE GUIDED WAVE ULTRASONIC TESTING REPORT Our Reference : -
Test Date : February 24, 2023
Client : Harbour Energy Job No. : -
Project : MRUT (CPUS) Equipment : PowerBox H Tuning Module : 205T0015-LF
Item No. : M01 CSU Sensor : 205C0469 Scanner : PN 274A0244
Drawing No. : - Tested Material : Carbon Steel/A36
Acceptance Standard :- Procedure No. : ExWI-NDT-18052
Stage of Examination As Weld As Base Metal After Repair Coaxial Cable Type/ Length : 1.5 m
After weld 12 Hrs. Before PWHT After PWHT Other Ref./ Sensitivity Setting : Flat Bottom Holes  mm
Surface Preparation Grinding Brushing by power tool Scanning Sensitivity : + 6 dB Scanning Speed : >150 mm/s
Location Sizing
Location No. Indication No. Findings (Indications) Remarks / Follow up Priority
X-Line Y-Line Width Amplitude (%) Estimated Wall loss
10-HC-20-0209-1A3 (S16) - - - - - - No anomaly indication was detected N/A

Remark/Test Restriction : WL ≤ 25% ( WL≤1.78 ; 25% < WL ≤ 50% (1.78<WL≤3.56) ; WL > 50% (WL>3.56) Estimated Cross - Sectional Wall Loss
P1: High P2: Medium P3: Low P2: Estimated Measured thickness <= nominal-corrosion allowance, P3: Estimated measured thickness >= nominal-corrosion allowance
1.3 < Estimated Measured thickness <= 3 mm, P1 for HC service, P2 nonhydrocarbon service, P3 for portable water
P1: Estimated measured thickness <=1.3

Completed by Performed by Reviewed by Witnessed / Reviewed by Witnessed / Reviewed by Witnessed / Reviewed by


Company Qualitech PLC. Qualitech PLC.
Signature
Name Mr. Thongphan P. Mr. Chalermphol K.
Position ASNT UT Level II ASNT UT Level II
Date February 24, 2023 February 24, 2023
Report No. : HE-MRUT-001/23 Page 2 of 3
MEDIUM RANGE GUIDED WAVE ULTRASONIC TESTING REPORT Our Reference : -
Test Date : February 24, 2023
INDICATION RECORD
PIPE Dia. 10" (Corrosion Under Pipe Support)
Point No. S1
Pipe Dia. : 10 inch
Test Range 0.0 - 2,400 mm.

Findings (Indications)

W1 No anomaly indication was detected 0º


- - Flange signal
TP 1
90º
10-HC-20-0209-1A3 (S16)

180º
Tested area

270º

Remark: OD = 10" (273.1 mm.)


Remark: Tested Area Thickness = 6.35 mm.
Circumference = 857.5 mm.
Tested distance = 2,400 mm.
Report No. : HE-MRUT-001/23 Page 3 of 3
MEDIUM RANGE GUIDED WAVE ULTRASONIC TESTING REPORT Our Reference : -
Test Date : February 24, 2023
DISTANCE AMPLITUDE CURVE (Pipe diameter 6" ; Thickness 7.11 mm.)

3.35 mm. < wall loss ≤ 5.33 mm.

Findings (Indications)

W1 1.77 mm. < wall loss ≤ 3.55 mm. No anomaly indication was detected

TP 1

Wall loss ≤ 1.77 mm.


WL ≤ 25% ( WL≤1.78 ; 25% < WL ≤ 50% (1.78<WL≤3.56) ; WL > 50% (WL>3.56) Estimated Cross - Sectional Wall Loss