Nothing Special   »   [go: up one dir, main page]

300 Ma Catalog

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

HINDLAND EQUIPMEN

HINDLAND H RAY 300


HRAY300 diagnostic High Quality X-ray generator
IMAGE 100
200
300

Equipment
mA

MAINS

RESET mA mAS KVP

SYSTEM
READY

OFF

ON
BUCKY

RAY
TABLE VERTICAL COLIMETER I EXPOSER II EXPOSER 300
CAUTION X-RAY
R A D I AT I O N HAZARD
THIS EQUIPMENT MAY BE DANGEROUS TO THE PATIENT
AND THE OPERATOR, UNLESS SAFE EXPOSURE FACTORS,
OPERATING INSTRUCTIONS AND REGULAR MAINTENANCE
SCHEDULES ARE FOLLOWED.

Control Panel:-

mA up mA up / down selector
mAs up MAs time selector
KVP Kvp up / down selector
Table Bucky Table BUCKY on / off
Vertical Bucky Vertical BUCKY on/off
Collimator Collimator on/off
I Exposure I Exposure ready
II Exposure X- Ray Exposure
Reset Parameters Reset
X-Ray X Ray indicator
Mains Main power supply indicator
System ready Machine ready indicator
ON Machine switch on button
OFF Machine switch off button
Volt Volt meter (220v indicator)
mA up Current meter
Technical Specification Model: HRAY 300

Type of Model Static (Floor to Ceiling)


Power Supply Two Phase
Input Voltage 415 VAC, 50/60 Hz
Control Panel Digital display control based
mA Range 50, 100, 200, & 300 mA
mAs Range 4 to 600 (6 sec.)
KVP Range 40 to 125 KVP
Digital Display mA, mAs, KVP Displayed on
Control Panel
Power Rating 24 kW
Type of X-Ray Tube Rotating Anode (20/40 dual focus)

X-RAY Tube Data:-


These tube have focus 2.0 & 1.0 and are available for maximum tube
voltage 125 kV.
Class I ME Equipment as per IEC Classification ( IEC60601-1:2005)
X-ray Tube voltage - 125 kV.
.
Nominal Focal Spot Value large focus - 2.0, small Focus 1.0.
.
Nominal Radiographic Anode Input Power : At - , .
50 Hz 60 Hz
Large Focus 42.5 kW 47 kW
Small Focus 21 kW 22.5 kW
Salient Features:
 Microcontroller Based, Easy Operational and user friendly X-Ray Control Console.

 Auto shut down Facilities(Collimator will automatically switched off).

 Certified Silicon/PVC wires used for internal wiring for protection against heat and fire.

Microntroller based Program protects X-Ray Tube life from overload due to exposure time.

 Powerful circuit design provides maximum mA and Kvp output accuracy (actual result).

 Two types of Exposure switches (wire hand switch and Touch switches on control console)

 Audio Tone at the time of X-RAY Exposure.

 Booster transfarmer used in filament circuit.

 Movements of Tube (up & down) controlled by electro-mechanical device.

 Measuring Tape and LED Based Collimator.

 HRAY 300 is protected by its in build protection circuits, Fuses and MCBs .

Results:

HINDLAND EQUIPMENT
103,First Floor, Vardhman Master Plaza, DDA LSC Market, Ghazipur Crossing,Delhi-110096,INDIA
Contact No.+91 11- 45390403,+91 9711780403 Email:Info@hindlandequipment.com,
hindlandequipment@gmail.com Website: hindlandequipment.com

You might also like