Manual
8.803.8001EN / 2019-09-26
Metrohm AG
CH-9100 Herisau
Switzerland
Phone +41 71 353 85 85
Fax +41 71 353 89 01
info@metrohm.com
www.metrohm.com
803 Ti Stand
Manual
8.803.8001EN / 2019-09-26
Technical Communication
Metrohm AG
CH-9100 Herisau
techcom@metrohm.com
Table of contents
1 Introduction 1
1.1 Instrument description ......................................................... 1
1.2 About the documentation ................................................... 1
1.2.1 Symbols and conventions ........................................................ 1
1.3 Safety instructions ................................................................ 2
1.3.1 General notes on safety ........................................................... 2
1.3.2 Electrical safety ........................................................................ 2
1.3.3 Working with liquids ................................................................ 3
1.3.4 Flammable solvents and chemicals ........................................... 3
1.3.5 Recycling and disposal ............................................................. 4
4 Troubleshooting 15
4.1 Problems .............................................................................. 15
5 Technical specifications 16
5.1 Rotational speed ................................................................. 16
5.2 Pump .................................................................................... 16
5.3 Power supply ...................................................................... 16
5.4 Ambient temperature ......................................................... 16
5.5 Dimensions .......................................................................... 17
5.6 Material of housing ............................................................ 17
6 Accessories 18
Table of figures
Figure 1 Front 803 Ti Stand ............................................................................. 5
Figure 2 Rear 803 Ti Stand .............................................................................. 6
Figure 3 Connecting the 803 Ti Stand ........................................................... 10
Figure 4 Connecting the Dosino to the 803 Ti Stand ..................................... 11
Figure 5 803 Ti Stand with volumetric titration vessel and equipment for auto-
matic reagent exchange. ................................................................. 12
1 Introduction
CAUTION
Warning
This symbol draws attention to a possible hazard due
to heat or hot instrument parts.
Warning
This symbol draws attention to a possible biological
hazard.
Caution
This symbol draws attention to a possible damage of
instruments or instrument parts.
Note
This symbol marks additional information and tips.
WARNING
WARNING
WARNING
WARNING
CAUTION
Periodically check all system connections for leaks. Observe the relevant
regulations in respect to working with flammable and/or toxic fluids
and their disposal.
WARNING
5
Figure 1 Front 803 Ti Stand
5 Key
Pressing the key pumps air into the solvent
bottle. The overpressure in the solvent bottle
pushes solvent into the KF titration cell.
Waste
Solvent
3 MSB
1 Connection nipple for PVC tubing 2 Connection nipple for PVC tubing
For aspirating the titration vessel content. For aspirating solvent.
3 Installation
3.1.2 Checks
Immediately after receipt, check whether the shipment has arrived com-
plete and without damage by comparing it with the delivery note.
3.1.3 Location
The instrument has been developed for operation indoors and may not be
used in explosive environments.
Place the instrument in a location of the laboratory which is suitable for
operation and free of vibrations and which provides protection against
corrosive atmosphere and contamination by chemicals.
The instrument should be protected against excessive temperature fluctua-
tions and direct sunlight.
6.2001.060
2 Attach the opening on the bottom of the KF titration stand onto the
hexagon screw in the stand plate.
3 Slide the 6.2016.070 support rod from above into the opening of the
KF titration stand intended for this purpose up to the hexagon screw
and tighten.
6.2016.070
6.1414.030
2
3 4
6.2013.010
1
6.1415.220
6.1903.020
2 Mount the 6.1414.030 vessel lid of the KF titration cell to the sup-
port rod. Keep the locking lever pressed down until it can be released
at the desired position.
4 Press the holding bracket downwards in order to fix the titration ves-
sel. The levers of the holding bracket must enclose the pins of the
plastic ring on the titration vessel in order to ensure a secure hold.
5 Adjust the height of the KF titration cell by pressing the locking lever.
It should almost touch the surface of the stirrer. The position can
now be fixed by readjusting the clamping ring.
Once the height of the KF titration cell has been adjusted correctly,
the entire cell can be raised and swiveled to the right as required by
pressing the locking lever.
Waste
Solvent
MSB
Waste
Solvent
MSB
1 4 12 20
21
2 5 16
10 13 22
6 17
21
7
3
8 18
23
11 14
9 15
Figure 5 803 Ti Stand with volumetric titration vessel and equipment for automatic reagent
exchange.
23 Cannula 6.1819.030
4 Cut the 6.1801.120 PVC tubing into two halves and use one to aspi-
rate.
5 Fasten the one end of the aspiration tubing to the tubing adapter,
the other to the connection nipple for the waste on the rear of the
titration stand.
8 Screw the 6.1543.120 aspiration tip to the other end of the PTFE
tubing.
9 Insert the aspiration tip down to the bottom of the titration vessel to
be emptied and fasten it to the titration vessel lid.
NOTICE
2 Use the other half of the 6.1801.120 PVC tubing previously cut in
two pieces for aspirating the solvent. Fasten the one end of the tub-
ing to the lower end of the adsorber tube, the other end to the con-
nection nipple for aspirating the solvent.
5 Insert the 6.1819.030 cannula into the last open hole (with medium-
sized diameter) of the 6.1602.105 bottle attachment.
7 Screw the 6.1543.110 transfer tip to the free end of the 6.1805.200
PTFE tubing, insert into the titration vessel and fasten to the titration
vessel lid.
4 Troubleshooting
4.1 Problems
Problem Cause Remedy
Solvent is added at The drying tube is blocked. ■ Enlarge the hole of the drying tube cover
the same time dur- to 2 mm at least.
ing aspiration. ■ Refill the drying tube, not packing too
tightly, eventually removing some of the
molecular sieve.
The pump conveys The add/aspirate key is not ■ It is usually the case that the bottle attach-
no liquid. pressed tightly enough. ments are not screwed tightly enough to
the reagent and waste bottles.
■ Check all connections for leak-tightness.
■ Check whether the 803 Ti Stand has been
set up correctly.
The solvent flows on The solvent bottle is not set Set the solvent bottle up in such a way that
into the titration up correctly. the liquid level in the bottle is lower than that
vessel after the in the titration vessel.
addition, without
the add key being
pressed.
5 Technical specifications
5.2 Pump
Add > 600 mL/min. (at 25 °C; standard accessories)
Aspirate > 400 mL/min. (at 25 °C; standard accessories)
5.5 Dimensions
Width 106 mm
Height (without 101 mm
stand)
Height (with 412 mm
stand)
Depth 220 mm
Weight 1100 g
6 Accessories
Up-to-date information on the scope of delivery and optional accessories
for your product can be found on the Internet. You can download this
information using the article number as follows:
2 Enter the article number (e.g. 803) into the search field.
The search result is displayed.
NOTICE