Waukesha Product Options 2022 9 26 22
Waukesha Product Options 2022 9 26 22
Waukesha Product Options 2022 9 26 22
NOTE:
Revision bars along the left margin and red highlighted text indicate
changes made since previous version of this price book.
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications, and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. June 2022
PAGE MP-2
DATA COLLECTOR
1020 Adds shipped-loose remote monitoring data collector hardware enable data collection for gas compressors and balance of plant
equipment. Data collector can connect to 5 packages. A package is defined as an engine + compressor. C1D2 and ATEX
Zone 2 Rating .....................................................................................................................................................................................
CELLULAR ROUTER
1021 Adds shipped-loose 4G LTE cellular router, SIM card, whip antenna, and antenna magnetic mounting base for remote monitoring
network connectivity. NOTE: This kit is not needed if the customer has an internet connection at the site ...................................
1021A 4G/LTE router kit that includes the Digi WR31-L1. It covers Greece and Poland. ATEX Zone 2 Rating .........................................
1021B 3G router that includes the Digi WR31-U9. It works almost all over the world but should only be used where the other two options
are not applicable, as 4G/LTE is preferred. Coverage includes Algeria, Argentina, Australia, Bahrain, Bangladesh, Bolivia,
Columbia, Ecuador, Egypt, India, Indonesia, Mexico, New Zealand, Nigeria, Oman, Pakistan, Peru, Russia, Singapore,
Thailand, Trinidad, United Arab Emirates, and Venezuela. HSPA + Rating ....................................................................................
CELLULAR BOOSTER
1022 Adds shipped-loose remote monitoring data collector hardware enable data collection for gas compressors and balance of plant
equipment. Data collector can connect to 5 packages. A package is defined as an engine + compressor. C1D2 and ATEX Zone
2 Rating...............................................................................................................................................................................................
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications, and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. June 2022
PAGE GC VHP-1
Engines purchased with optional emPact Emission Control System include 3-way catalyst with capability to achieve:
Housings are available in either carbon steel or stainless steel (“S” suffix)
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. June 2022
PAGE GC VHP-2
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. June 2022
PAGE GC VHP-3
F3514GSI & F3524GSI TURBOCHARGED AND INTERCOOLED GAS ENGINE FOR GAS COMPRESSION
9.375 Inch (238 mm) Bore x 8.5 Inch (216 mm) Stroke – 6 Cylinders
3520 Cubic Inch (57.7 Liter) Displacement
STANDARD EQUIPMENT
AIR CLEANER - Dry type with rain shield and service indicator. ENGINE MONITORING DEVICES – Factory-mounted sensors and
AIR FUEL RATIO CONTROL (AFR) – 2nd generation AFR2 integrates harnessing for pre- and post-filter lube oil pressure, oil temperature,
with ESM2 for enhanced rich-burn engine control. Utilizes fuel intake manifold temperature and pressure, crankcase pressure,
control valve between regulator and carburetor and enhanced pre- turbocharger boost pressure, jacket water temperature, post turbine
catalyst O2 sensor optimized for gaseous fuels for more stable exhaust temperatures, main bearing temperatures, exhaust port
operation through fuel swings. Optional emPact Emission Control temperatures and exhaust O2 content, all accessible through the
System adds 3-way catalyst sized for 0.15 g/bhp-hr NOx and 0.30 ESM2 interface. ESM2 continually monitors combustion
g/bhp-hr CO or 1.0 g/bhp-hr NOx and 1.0 g/bhp-hr CO. Stainless performance through individual knock sensors to provide detonation
steel or carbon steel catalyst housing. emPact also adds post- protection. Includes adjustable oil pressure permissive prior to start
catalyst O2 sensor for closed-loop control, adjusting air/fuel ratio signal. Dual magnetic pick-ups are used for accurate engine speed
based on catalyst output, and pre- and post-catalyst temperature monitoring. ESM2 provides diagnostics information related to
and pressure sensors for simplified maintenance and emission engine performance and sensor validity. Sensors meet Canadian
reporting. Standard AFR2 control system meets Canadian Standards Association Class I, Division 2, Group A, B, C, & D
Standards Association Class I, Division 2, Group A, B, C, & D (Canada & US) hazardous location requirements.
(Canada & US) hazardous location requirements. ENGINE ROTATION - Counterclockwise when facing flywheel.
ALTERNATOR - Alternator – Denso, 24V DC, 50A, Brushless, belt EXHAUST OUTLET – Single vertical at rear. Flexible stainless-steel
driven direct off crankshaft. Includes engine mounted junction box connection with 6” (152 mm) pipe flange.
for connection to battery. Alternator system meets Canadian EXHAUST THERMOCOUPLES – Seven K-type. ESM2 system
Standard Association Class I, Division 2, Group A, B, C & D (Canada incorporates exhaust port and pre-turbine thermocouples as
& US) hazardous location requirements (Code 3433E).
standard equipment, including high exhaust temperature shutdown
BARRING DEVICE - Manual.
BATTERY BOX - Designed to accommodate two series 31 12 VDC safeties. Thermocouples are read by the ESM2 STU (Smart
batteries. Includes power disconnect switch and 20 foot (6.1 m) Thermocouple Unit) and temperature and fault information is
cable for connection to ESM2 Power Distribution Box. displayed on the ESM2 Display Panel. No customer connections
BEARINGS - Heavy duty, replaceable, precision type. required.
BREATHER – Self-regulating, closed system. FLYWHEEL - Approx. WR2 = 155000 lb-in2; with ring gear (208 teeth),
CONNECTING RODS - Drop forged steel, rifle drilled. machined to accept two drive adapters. Machined for 22.5” (572
CONTROL SYSTEM - Waukesha Engine System Manager 2 (ESM2*) mm) pilot bore, 20.5” (521 mm) bolt circle, (8) 1.00”-8 tapped holes; or
integrates spark timing control, speed governing, detonation 28.875″ (733 mm) pilot bore, 27.25” (692 mm) bolt circle, (12) 0.75”-10
protection, misfire detection, start-stop control, diagnostic
tapped holes. (Code 1161C).
information, fault logging, engine safeties and AFR2 (Air/Fuel Ratio)
control in one Engine Control Unit (ECU). One customer connection FLYWHEEL HOUSING - No. 00 SAE.
to the control system via a 50-foot Customer Interface harness (15.2 FRONT STUB SHAFT – 3.5" (89 mm) diameter x 11.75" (292 mm) long,
m). ESM2 also provides a MODBUS RTU slave RS-485 connection standard keyway 7/8" (22 mm) x 7/16" (11 mm) x 8" (203 mm) keyway.
for integration into local panels. Customer connections are required Allows for customer supplied pulley sizes down to 8" (203 mm) pitch
to the local panel, fuel valve, and 24V DC power supply. Compatible diameter to customize fan drive speed. Not compatible with Code 1140A
with Woodward load sharing module. ESM2 meets Canadian or 1140B) (Code 8006).
Standards Association Class I, Division 2, Group A, B, C, & D FUEL SYSTEM – One natural gas, 4″ (102 mm) updraft carburetor
(Canada & US) hazardous location requirements. Includes 12” and one mounted Fisher 99, 2" (51 mm) gas regulator, 30-60 psi
ESM2 Display Panel.
(207-414 kPa) fuel inlet pressure required.
CRANKCASE - Integral crankcase and cylinder frame.
CRANKSHAFT - Forged steel, seven main bearings, Wire the customer-supplied fuel
counterweighted, and dynamically balanced. gas shutoff valve to be
CYLINDERS - Removable wet type bainitic cast iron cylinder liners, controlled by ESM2. If the fuel
chrome plated on outer diameter. valve is controlled independently of ESM2, fault codes will occur
CYLINDER HEADS - Six interchangeable. Four valves per cylinder, when the fuel valve is not actuated in sequence with the ESM2.
with water cooled exhaust valve seats. Roller valve lifters and GOVERNOR - Electric throttle actuator controlled by ESM2 with
hydraulic push rods. Flange mounted ignition coils.
throttle position feedback. Governor tuning is performed using the
DISPLAY PANEL, ESM2 – ESM2 Display Panel comes standard and is
a required part of the ESM2 system, allowing for user parameter ESM2 Display Panel. ESM2 includes option of a load-coming
adjustments, fault information viewing and continuous data logging feature to improve engine response to predictable step loads.
capability over the lifetime of the product. The standard ESM2 Display IGNITION SYSTEM - Ignition Power Module Diagnostics (IPM-D) -
Panel is a 12” (0.3m) resistive-touch full-color display, incorporating controlled by ESM2, with spark timing optimized for varying speed-
service tool functionality, on-screen E-Help troubleshooting information load conditions. Dual voltage energy levels automatically controlled
for ESM2 faults, and technical documentation such as manuals and by ESM2 to maximize spark plug life and improve starting. The
service bulletins. The ESM2 HMI is shipped loose and mounted in the diagnostics feature of ESM2 can be used to help monitor spark plug
customer control panel and meets CSA Class I, Div 2, Group A, B, C & life, aiding with predictive maintenance. Shielded ignition
D (Canada & US) hazardous location requirements. ESM2 Display
components meet Canadian Standard Association Class I, Division
Panel provide Remote Monitoring & Diagnostic (RM&D) capability
for engine only. Optional data collector available for compressor 2, Group A, B, C, D (Canada & US) hazardous location
and/or balance of plant. requirements.
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. June 2022
PAGE GC VHP-4
F3514GSI & F3524GSI TURBOCHARGED AND INTERCOOLED GAS ENGINE FOR GAS COMPRESSION
(Continued)
INTERCOOLER - Air-to-water. PAINT - Oilfield orange primer.
LEVELING BOLTS PISTONS - Aluminum with floating pin. Oil cooled. 8:1 compression
LIFTING EYES – Requires 9.5 ton Working Load Limit (W.L.L. anchor ratio.
shackles. STARTER – High pressure, air or gas TDI T109, inertia engaged,
LUBRICATION - Full pressure, gear type pump. Full flow lube oil filter, mounted with strainer and valve. Minimum supply pressure 90 psi.
20 gallon (76 Liters) capacity, with replaceable depth-type elements Maximum supply pressure 150 psi (Code 9208).
and flexible connections, shipped loose. Centrifugal bypass filter, SHIPPING SKID - For domestic truck or rail.
engine mounted. Lube oil strainer, mounted. Air/gas motor driven TURBOCHARGER - (1) with water-cooled bearing housing and
prelube pump, requires final piping. adjustable wastegate.
MAIN BEARING THERMOCOUPLES – Seven K-type. The ESM2 VIBRATION DAMPER - Viscous type.
system incorporates the main bearing thermocouples as standard WATER CIRCULATING SYSTEM, AUXILIARY CIRCUIT - Belt driven
equipment, including high temperature shutdown safeties. water circulating high capacity pump for intercooler and lube oil
Thermocouples are read by the ESM2 STU (Smart Thermocouple cooler. See S6543–19 performance curve for use with standard 10”
Unit) and temperature and fault information is displayed on the diameter crankshaft pulley. Auxiliary water circuit thermostatic valve for
ESM2 Display Panel. No customer connections required. 130° F (54° C) intercooler water temperature.
MANIFOLD - Exhaust, water cooled. WATER CIRCULATING SYSTEM, ENGINE JACKET - Belt driven
OIL COOLER - Shell and tube type with thermostatic temperature water circulating pump. Cluster type thermostatic temperature
controller and pressure regulating valve. Mounted on left hand side. regulating valve, full flow bypass type with 165° - 170°F (74° - 77°C)
OIL PAN - Base type. 72 gallon (273 L) capacity including filter and start to open thermostats. ANSI 4″ (102 mm) 125 psi flange
cooler. connections on inlet and outlet.
AIR CLEANERS
NOTE: Precleaners are recommended for applications in dusty environments, or when dust conditions are
unpredictable.
2320B X Precleaner – Heavy duty inertia separator, for standard air cleaner.. ........................................................................
ELECTRICAL
3441 X Delete Standard ESM battery box and cable. Customer is responsible for proper sizing of wire from battery to ESM
Power Distribution Box. ..............................................................................................................................................
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. June 2022
PAGE GC VHP-6
F3524GSI
F3514GSI
LUBRICATION
5022 X Regulator – Lubricating oil level. Kenco model LCE with explosion-proof electric low level SPDT safety switch and
Fire Safe features. Meets CSA Class I, Division 2, Group B, C, & D requirements. For oil supply with up to 15ft.
of static head. Mounted in place of standard crankcase inspection door ................................................................
CONTROLS
6012 X Valve – BICERA crankcase explosion relief. Four (4) required ..................................................................................
6190F X Magnetic Pickup – Mounted. Meets Canadian Standards Association Class I, Division 2, Group A, B, C, D, T4
hazardous location requirements .............................................................................................................................
6680 X 15" ESM2 HMI Display Panel -- Replaces standard 12" ESM2 HMI Display Panel .................................................
6680A X 19" ESM2 HMI Display Panel -- Replaces standard 12" ESM2 HMI Display Panel .................................................
MISCELLANEOUS
9974Q X Engine/Enginator that is Customs Union Compliant (Russia, Belarus, and Kazakhstan). Includes SERIAL
NUMBER SPECIFIC Technical Passport & Safety Justification in Russian and English, Engine Operator's
Manuals (one in Russian and one in English), and EAC label on unit. Enginators include supplied equipment
manuals that are in English only. May require additional lead time, consult factory for delivery information ......
9974U X Engine that is CE Mark Compliant. Includes a SERIAL NUMBER SPECIFIC Declaration of Incorporation and
Operator's Manual both in English. It is the responsibility of the entity (Packager, Distributor) placing the
complete package on the European market to ensure that the final complete package (machine) is properly CE
Marked and that the final customer is provided with the required translated manuals. Waukesha can assist with
translations at additional cost, contact Applications/Sales ....................................................................................
9974X X Required Label for Hazardous Location CSA Certification in US & Canada End Use. Adds a safety label
containing English and French language that is required to comply with the certification terms of the equipment.
Note: For end uses classified as Hazardous Locations Division 2 and in US & Canada. Contact Application
Engineering for use in other countries. ....................................................................................................................
9998A X Shipping Skid – For overseas container .....................................................................................................................
EXTENDED WARRANTY
10000AA X 6-Cylinder VHP Engine Extended Warranty -- 1 Year. Extended warranty excludes wear items and includes only
warrantable items as defined in Express Limited Warranty (ELW). Must be purchased at time of original order.
If applicable, the proper deferral process and preservation as outlined in Service Bulletin 16-1855H (or most
current) and WEDA 542 (or most current) must be followed or warranty extension is void. Emission warranties
for Waukesha’s emPact Emission Control System are NOT EXTENDED by Extended Engine Warranties........
10000BB X 6-Cylinder VHP Engine Extended Warranty -- 2 Years. Extended warranty excludes wear items and includes only
warrantable items as defined in Express Limited Warranty (ELW). Must be purchased at time of original order.
If applicable, the proper deferral process and preservation as outlined in Service Bulletin 16-1855H (or most
current) and WEDA 542 (or most current) must be followed or warranty extension is void. Emission warranties
for Waukesha’s emPact Emission Control System are NOT EXTENDED by Extended Engine Warranties........
10000CC X 6-Cylinder VHP Engine Extended Warranty -- 3 Years. Extended warranty excludes wear items and includes only
warrantable items as defined in Express Limited Warranty (ELW). Must be purchased at time of original order.
If applicable, the proper deferral process and preservation as outlined in Service Bulletin 16-1855H (or most
current) and WEDA 542 (or most current) must be followed or warranty extension is void. Emission warranties
for Waukesha’s emPact Emission Control System are NOT EXTENDED by Extended Engine Warranties........
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. June 2022
PAGE GC VHP-7
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. June 2022
PAGE GC VHP-8
STANDARD EQUIPMENT
AIR CLEANER – Two, 3″ dry type filter with hinged rain shield and temperatures and exhaust O2 content, all accessible through the ESM2
service indicator. interface. ESM2 continually monitors combustion performance through
AIR FUEL RATIO CONTROL (AFR) – 2nd generation AFR2 integrates individual knock sensors to provide detonation protection. Includes
with ESM2 for enhanced rich-burn engine control. Utilizes fuel adjustable oil pressure permissive prior to start signal. Dual magnetic
control valve between regulator and carburetor and enhanced pre- pick-ups are used for accurate engine speed monitoring. ESM2
catalyst O2 sensor optimized for gaseous fuels for more stable provides diagnostics information related to engine performance and
operation through fuel swings. Optional emPact Emission Control sensor validity. Sensors meet Canadian Standards Association Class I,
System adds 3-way catalyst sized for 0.15 g/bhp-hr NOx and 0.30 Division 2, Group A, B, C, & D (Canada & US) hazardous location
g/bhp-hr CO or 1.0 g/bhp-hr NOx and 1.0 g/bhp-hr CO. Stainless ENGINE ROTATION – Counterclockwise when facing flywheel.
steel or carbon steel catalyst housing. emPact also adds post- EXHAUST OUTLET – Single vertical at rear. Flexible stainless steel
catalyst O2 sensor for closed-loop control, adjusting air/fuel ratio connection with 8” (203 mm) pipe flange.
based on catalyst output, and pre- and post-catalyst temperature EXHAUST THERMOCOUPLES – 14 K-Type. ESM2 system
and pressure sensors for simplified maintenance and emission incorporates exhaust port and pre-turbine thermocouples as
reporting. Standard AFR2 control system meets Canadian standard equipment, including high exhaust temperature shutdown
Standards Association Class I, Division 2, Group A, B, C, & D safeties. Thermocouples are read by the ESM2 STU (Smart
(Canada & US) hazardous location requirements.
Thermocouple Unit) and temperature and fault information is
ALTERNATOR - Alternator – Denso, 24V DC, 50A, Brushless, belt
driven direct off crankshaft. Includes engine mounted junction box displayed on the ESM2 Display Panel. No customer connections
for connection to battery. Alternator system meets Canadian required.
Standard Association Class I, Division 2, Group A, B, C & D (Canada FLYWHEEL – Approx. WR2 = 155000 lb-in2; with ring gear (208 teeth),
& US) hazardous location requirements (Code 3433E). machined to accept two drive adapters. Machined for 22.5” (572
BARRING DEVICE – Manual. mm) pilot bore, 20.5” (521 mm) bolt circle, (8) 1.00”-8 tapped holes; or
BATTERY BOX – Ship loose battery box designed to accommodate 28.875″ (733 mm) pilot bore, 27.25” (692 mm) bolt circle, (12) 0.75”-10
two Series 31 12 VDC batteries. Includes power disconnect switch tapped holes. (Code 1161C).
and 20 foot (6.1 m) cable for connection to ESM2 * Power Distribution FLYWHEEL HOUSING – No. 00 SAE.
Box. FUEL SYSTEM – Single 3″ ANSI flange fuel inlet connection. Two
BEARINGS – Heavy duty, replaceable, precision type. natural gas, 4″ (102 mm) updraft carburetors and two mounted
BREATHER – Self-regulating, closed system. Fisher 99, 2” (51 mm) gas regulators. 30 – 60 psi fuel inlet pressure
CONNECTING RODS – Drop forged steel, rifle drilled. required. Fuel control valve located between regulator and
CONTROL SYSTEM - Waukesha Engine System Manager 2 (ESM2*)
carburetor replaces stepper motor.
integrates spark timing control, speed governing, detonation
protection, misfire detection, start-stop control, diagnostic Wire the customer-supplied fuel
information, fault logging, engine safeties and AFR2 (Air/Fuel Ratio) gas shutoff valve to be controlled
control in one Engine Control Unit (ECU). One customer connection by ESM2. If the fuel valve is
to the control system via a 50-foot Customer Interface harness (15.2 controlled independently of ESM2, fault codes will occur when
m). ESM2 also provides a MODBUS RTU slave RS-485 connection the fuel valve is not actuated in sequence with the ESM2.
for integration into local panels. Customer connections are required
to the local panel, fuel valve, and 24V DC power supply. Compatible FRONT STUB SHAFT – 3.5" (89 mm) diameter x 11.75" (292 mm) long,
with Woodward load sharing module. ESM2 meets Canadian standard keyway 7/8" (22 mm) x 7/16" (11 mm) x 8" (203 mm) keyway.
Standards Association Class I, Division 2, Group A, B, C, & D Allows for customer supplied pulley sizes down to 8" (203 mm) pitch
(Canada & US) hazardous location requirements. Includes 12” diameter to customize fan drive speed. Not compatible with Code 1140A
ESM2 Display Panel. or 1140B (Code 8006).
CRANKCASE – Integral crankcase and cylinder frame GOVERNOR - Electric throttle actuator controlled by ESM2 with
CRANKSHAFT – Forged steel, seven main bearings, throttle position feedback. Governor tuning is performed using the
counterweighted and dynamically balanced. ESM2 Display Panel. ESM2 includes option of a load-coming
CYLINDERS – Removable wet type cylinder liners. feature to improve engine response to predictable step loads.
CYLINDER HEADS – Twelve interchangeable. Four valves per IGNITION SYSTEM - Ignition Power Module Diagnostics (IPM-D) -
cylinder, with water cooled exhaust valve seats. Roller valve lifters controlled by ESM2, with spark timing optimized for varying speed-
and hydraulic push rods. Flange mounted ignition coils. load conditions. Dual voltage energy levels automatically controlled by
DISPLAY PANEL, ESM2 – ESM2 Display Panel comes standard and is ESM2 to maximize spark plug life and improve starting. The
a required part of the ESM2 system, allowing for user parameter
diagnostics feature of ESM2 can be used to help monitor spark plug
adjustments, fault information viewing and continuous data logging
capability over the lifetime of the product. The standard ESM2 Display life, aiding with predictive maintenance. Shielded ignition components
Panel is a 12” (0.3m) resistive-touch full-color display, incorporating meet Canadian Standard Association Class I, Division 2, Group A, B,
service tool functionality, on-screen E-Help troubleshooting information C, D (Canada & US) hazardous location requirements.
for ESM2 faults, and technical documentation such as manuals and INTERCOOLER – Air-to-water.
service bulletins. The ESM2 HMI is shipped loose and mounted in the LEVELING BOLTS
customer control panel and meets CSA Class I, Div 2, Group A, B, C & LIFTING EYES – Requires 9.5 ton Working Load Limit (W.L.L.) anchor
D (Canada & US) hazardous location requirements. ESM2 Display shackles.
Panel provide Remote Monitoring & Diagnostic (RM&D) capability LUBRICATION – Full pressure, gear type pump. Engine mounted full
for engine only. Optional data collector available for compressor
flow lube oil micro-fiberglass filters with mounted differential
and/or balance of plant.
ENGINE MONITORING DEVICES – Factory-mounted sensors and pressure gauge. Centrifugal bypass filter, engine mounted. Air/gas
harnessing for pre- and post-filter lube oil pressure, oil temperature, motor driven pre-lube pump, requires final piping.
intake manifold temperature and pressure, crankcase pressure, MAIN BEARING THERMOCOUPLES – Seven K-type. The ESM2
turbocharger boost pressure, jacket water temperature, post turbine system incorporates the main bearing thermocouples as standard
exhaust temperatures, main bearing temperatures, exhaust port equipment, including high temperature shutdown safeties.
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. June 2022
PAGE GC VHP-10
STANDARD EQUIPMENT
AIR CLEANER – Two, 3″ dry type filter with hinged rain shield and temperatures and exhaust O2 content, all accessible through the
service indicator. ESM2 interface. ESM2 continually monitors combustion
AIR FUEL RATIO CONTROL (AFR) – 2nd generation AFR2 integrates performance through individual knock sensors to provide
with ESM2 for enhanced rich-burn engine control. Utilizes fuel detonation protection. Includes adjustable oil pressure permissive
control valve between regulator and carburetor and enhanced pre- prior to start signal. Dual magnetic pick-ups are used for accurate
catalyst O2 sensor optimized for gaseous fuels for more stable engine speed monitoring. ESM2 provides diagnostics information
operation through fuel swings. Optional emPact Emission Control related to engine performance and sensor validity. Sensors meet
System adds 3-way catalyst sized for 0.15 g/bhp-hr NOx and 0.30 Canadian Standards Association Class I, Division 2, Group A, B, C,
g/bhp-hr CO or 1.0 g/bhp-hr NOx and 1.0 g/bhp-hr CO. Stainless & D (Canada & US) hazardous location
steel or carbon steel catalyst housing. emPact also adds post- ENGINE ROTATION – Counterclockwise when facing flywheel.
catalyst O2 sensor for closed-loop control, adjusting air/fuel ratio EXHAUST OUTLET – Single vertical at rear. Flexible stainless steel
based on catalyst output, and pre- and post-catalyst temperature connection with 8” (203 mm) pipe flange.
and pressure sensors for simplified maintenance and emission EXHAUST THERMOCOUPLES – 14 K-Type. ESM2 system
reporting. Standard AFR2 control system meets Canadian incorporates exhaust port and pre-turbine thermocouples as
Standards Association Class I, Division 2, Group A, B, C, & D standard equipment, including high exhaust temperature shutdown
(Canada & US) hazardous location requirements. safeties. Thermocouples are read by the ESM2 STU (Smart
ALTERNATOR - Alternator – Denso, 24V DC, 50A, Brushless, belt
Thermocouple Unit) and temperature and fault information is
driven direct off crankshaft. Includes engine mounted junction box
for connection to battery. Alternator system meets Canadian displayed on the ESM2 Display Panel. No customer connections
Standard Association Class I, Division 2, Group A, B, C & D (Canada required.
& US) hazardous location requirements (Code 3433E). FLYWHEEL – Approx. WR2 = 155000 lb-in2; with ring gear (208 teeth),
BARRING DEVICE – Manual. machined to accept two drive adapters. Machined for 22.5” (572
BATTERY BOX – Ship loose battery box designed to accommodate mm) pilot bore, 20.5” (521 mm) bolt circle, (8) 1.00”-8 tapped holes; or
two Series 31 12 VDC batteries. Includes power disconnect switch 28.875″ (733 mm) pilot bore, 27.25” (692 mm) bolt circle, (12) 0.75”-10
and 20 foot (6.1 m) cable for connection to ESM2* Power Distribution tapped holes. (Code 1161C).
Box. FLYWHEEL HOUSING – No. 00 SAE.
BEARINGS – Heavy duty, replaceable, precision type. FUEL SYSTEM – Single 3″ ANSI flange fuel inlet connection. Two
BREATHER – Self-regulating, closed system. natural gas, 4″ (102 mm) updraft carburetors and two mounted
CONNECTING RODS – Drop forged steel, rifle drilled. Fisher 99, 2” (51 mm) gas regulators. 40 – 60 psi fuel inlet pressure
CONTROL SYSTEM - Waukesha Engine System Manager 2 (ESM2*) required. Fuel control valve located between regulator and
integrates spark timing control, speed governing, detonation
carburetor replaces stepper motor.
protection, misfire detection, start-stop control, diagnostic
information, fault logging, engine safeties and AFR2 (Air/Fuel Ratio) Wire the customer-supplied fuel
control in one Engine Control Unit (ECU). One customer connection gas shutoff valve to be controlled
to the control system via a 50-foot Customer Interface harness (15.2 by ESM2. If the fuel valve is
m). ESM2 also provides a MODBUS RTU slave RS-485 connection controlled independently of ESM2, fault codes will occur when
for integration into local panels. Customer connections are required the fuel valve is not actuated in sequence with the ESM2.
to the local panel, fuel valve, and 24V DC power supply. Compatible
with Woodward load sharing module. ESM2 meets Canadian FRONT STUB SHAFT – 3.5" (89 mm) diameter x 11.75" (292 mm) long,
Standards Association Class I, Division 2, Group A, B, C, & D standard keyway 7/8" (22 mm) x 7/16" (11 mm) x 8" (203 mm) keyway.
(Canada & US) hazardous location requirements. Includes 12” Allows for customer supplied pulley sizes down to 8" (203 mm) pitch
ESM2 Display Panel. diameter to customize fan drive speed. Not compatible with Code 1140A
CRANKCASE – Integral crankcase and cylinder frame or 1140B (Code 8006).
CRANKSHAFT – Forged steel, seven main bearings, GOVERNOR - Electric throttle actuator controlled by ESM2 with
counterweighted and dynamically balanced. throttle position feedback. Governor tuning is performed using the
CYLINDERS – Removable wet type cylinder liners. ESM2 Display Panel. ESM2 includes option of a load-coming
CYLINDER HEADS – Twelve interchangeable. Four valves per feature to improve engine response to predictable step loads.
cylinder, with water cooled exhaust valve seats. Roller valve lifters IGNITION SYSTEM – 2nd generator Ignition Power Module Diagnostics
and hydraulic push rods. Flange mounted ignition coils. (IPMD2) - controlled by ESM2, with spark timing optimized for varying
DISPLAY PANEL, ESM2 – ESM2 Display Panel comes standard and is speed-load conditions. Optimized ignition energy levels, controlled by
a required part of the ESM2 system, allowing for user parameter ESM2, to maximize spark plug life and performance. The diagnostics
adjustments, fault information viewing and continuous data logging
features of IPMD2 and ESM2 can be used to help monitor spark plug
capability over the lifetime of the product. The standard ESM2 Display
Panel is a 12” (0.3m) resistive-touch full-color display, incorporating life, aiding with predictive maintenance. Shielded ignition components
service tool functionality, on-screen E-Help troubleshooting information meet Canadian Standard Association Class I, Division 2, Group A, B, C,
for ESM2 faults, and technical documentation such as manuals and D (Canada & US) hazardous location requirements.
service bulletins. The ESM2 HMI is shipped loose and mounted in the INTERCOOLER – Air-to-water.
customer control panel and meets CSA Class I, Div 2, Group A, B, C & LEVELING BOLTS
D (Canada & US) hazardous location requirements. ESM2 Display LIFTING EYES – Requires 9.5 ton Working Load Limit (W.L.L.) anchor
Panel provide Remote Monitoring & Diagnostic (RM&D) capability shackles.
for engine only. Optional data collector available for compressor LUBRICATION – Full pressure, gear type pump. Engine mounted full
and/or balance of plant. flow lube oil micro-fiberglass filters with mounted differential
ENGINE MONITORING DEVICES – Factory-mounted sensors and pressure gauge. Centrifugal bypass filter, engine mounted. Air/gas
harnessing for pre- and post-filter lube oil pressure, oil temperature, motor driven pre-lube pump, requires final piping.
intake manifold temperature and pressure, crankcase pressure, MAIN BEARING THERMOCOUPLES – Seven K-type. The ESM2
turbocharger boost pressure, jacket water temperature, post turbine system incorporates the main bearing thermocouples as standard
exhaust temperatures, main bearing temperatures, exhaust port equipment, including high temperature shutdown safeties.
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. June 2022
PAGE GC VHP-12
STANDARD EQUIPMENT
AIR CLEANER – Two, 3″ dry type filter with hinged rain shield and ENGINE MONITORING DEVICES – Factory-mounted sensors and
service indicator. harnessing for pre- and post-filter lube oil pressure, oil temperature,
AIR FUEL RATIO CONTROL (AFR) – 2nd generation AFR2 integrates intake manifold temperature and pressure, crankcase pressure,
with ESM2 for enhanced rich-burn engine control. Utilizes fuel turbocharger boost pressure, jacket water temperature, post turbine
control valve between regulator and carburetor and enhanced pre- exhaust temperatures, main bearing temperatures, exhaust port
catalyst O2 sensor optimized for gaseous fuels for more stable temperatures and exhaust O2 content, all accessible through the
operation through fuel swings. Optional emPact Emission Control
ESM2 interface. ESM2 continually monitors combustion
System adds 3-way catalyst sized for 0.15 g/bhp-hr NOx and 0.30
g/bhp-hr CO or 1.0 g/bhp-hr NOx and 1.0 g/bhp-hr CO. Stainless performance through individual knock sensors to provide detonation
steel or carbon steel catalyst housing. emPact also adds post- protection. Includes adjustable oil pressure permissive prior to start
catalyst O2 sensor for closed-loop control, adjusting air/fuel ratio signal. Dual magnetic pick-ups are used for accurate engine speed
based on catalyst output, and pre- and post-catalyst temperature monitoring. ESM2 provides diagnostics information related to
and pressure sensors for simplified maintenance and emission engine performance and sensor validity. Sensors meet Canadian
reporting. Standard AFR2 control system meets Canadian Standards Association Class I, Division 2, Group A, B, C, & D
Standards Association Class I, Division 2, Group A, B, C, & D (Canada & US) hazardous location
(Canada & US) hazardous location requirements. ENGINE ROTATION – Counterclockwise when facing flywheel.
ALTERNATOR - Alternator – Denso, 24V DC, 50A, Brushless, belt
EXHAUST OUTLET – Single vertical at rear. Flexible stainless steel
driven direct off crankshaft. Includes engine mounted junction box
for connection to battery. Alternator system meets Canadian connection with 8” (203 mm) pipe flange.
Standard Association Class I, Division 2, Group A, B, C & D (Canada EXHAUST THERMOCOUPLES – 14 K-Type. ESM2 system
& US) hazardous location requirements (Code 3433E). incorporates exhaust port and pre-turbine thermocouples as
BARRING DEVICE – Manual. standard equipment, including high exhaust temperature shutdown
BATTERY BOX – Ship loose battery box designed to accommodate safeties. Thermocouples are read by the ESM2 STU (Smart
two Series 31 12 VDC batteries. Includes power disconnect switch Thermocouple Unit) and temperature and fault information is
and 20 foot (6.1 m) cable for connection to ESM2 * Power Distribution displayed on the ESM2 Display Panel. No customer connections
Box. required.
BEARINGS – Heavy duty, replaceable, precision type. FLYWHEEL – Approx. WR2 = 155000 lb-in2; with ring gear (208 teeth),
BREATHER – Self-regulating, closed system. machined to accept two drive adapters. Machined for 22.5” (572
CONNECTING RODS – Drop forged steel, rifle drilled. mm) pilot bore, 20.5” (521 mm) bolt circle, (8) 1.00”-8 tapped holes; or
CONTROL SYSTEM - Waukesha Engine System Manager 2 (ESM2*) 28.875″ (733 mm) pilot bore, 27.25” (692 mm) bolt circle, (12) 0.75”-10
integrates spark timing control, speed governing, detonation tapped holes. (Code 1161C).
protection, misfire detection, start-stop control, diagnostic FLYWHEEL HOUSING – No. 00 SAE.
information, fault logging, engine safeties and AFR2 (Air/Fuel Ratio) FUEL SYSTEM – Single 3″ ANSI flange fuel inlet connection. Two
control in one Engine Control Unit (ECU). One customer connection natural gas, 4″ (102 mm) updraft carburetors and two mounted
to the control system via a 50-foot Customer Interface harness (15.2 Fisher 99, 2” (51 mm) gas regulators. 30 – 60 psi fuel inlet pressure
m). ESM2 also provides a MODBUS RTU slave RS-485 connection
required. Fuel control valve located between regulator and
for integration into local panels. Customer connections are required
to the local panel, fuel valve, and 24V DC power supply. Compatible carburetor replaces stepper motor.
with Woodward load sharing module. ESM2 meets Canadian Wire the customer-supplied fuel
Standards Association Class I, Division 2, Group A, B, C, & D gas shutoff valve to be controlled
(Canada & US) hazardous location requirements. Includes 12” by ESM. If the fuel valve is
ESM2 Display Panel. controlled independently of ESM, fault codes will occur when the
CRANKCASE – Integral crankcase and cylinder frame fuel valve is not actuated in sequence with the ESM.
CRANKSHAFT – Forged steel, seven main bearings,
counterweighted and dynamically balanced. FRONT STUB SHAFT – 3.5" (89 mm) diameter x 11.75" (292 mm) long,
CYLINDERS – Removable wet type cylinder liners. standard keyway 7/8" (22 mm) x 7/16" (11 mm) x 8" (203 mm) keyway.
CYLINDER HEADS – Twelve interchangeable. Four valves per Allows for customer supplied pulley sizes down to 8" (203 mm) pitch
cylinder, with water cooled exhaust valve seats. Roller valve lifters diameter to customize fan drive speed. Not compatible with Code 1140A
and hydraulic push rods. Flange mounted ignition coils. or 1140B (Code 8006).
DISPLAY PANEL, ESM2 – ESM2 Display Panel comes standard and is GOVERNOR - Electric throttle actuator controlled by ESM2 with
a required part of the ESM2 system, allowing for user parameter throttle position feedback. Governor tuning is performed using the
adjustments, fault information viewing and continuous data logging ESM2 Display Panel. ESM2 includes option of a load-coming
capability over the lifetime of the product. The standard ESM2 Display feature to improve engine response to predictable step loads.
Panel is a 12” (0.3m) resistive-touch full-color display, incorporating IGNITION SYSTEM - Ignition Power Module Diagnostics (IPM-D) -
service tool functionality, on-screen E-Help troubleshooting information controlled by ESM2, with spark timing optimized for varying speed-
for ESM2 faults, and technical documentation such as manuals and load conditions. Dual voltage energy levels automatically controlled
service bulletins. The ESM2 HMI is shipped loose and mounted in the
by ESM2 to maximize spark plug life and improve starting. The
customer control panel and meets CSA Class I, Div 2, Group A, B, C &
D (Canada & US) hazardous location requirements. ESM2 Display diagnostics feature of ESM2 can be used to help monitor spark plug
Panel provide Remote Monitoring & Diagnostic (RM&D) capability life, aiding with predictive maintenance. Shielded ignition
for engine only. Optional data collector available for compressor components meet Canadian Standard Association Class I, Division
and/or balance of plant. 2, Group A, B, C, D (Canada & US) hazardous location
requirements.
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. June 2022
PAGE GC VHP-14
.
L7044GSI TURBOCHARGED AND INTERCOOLED GAS ENGINE FOR GAS COMPRESSION
(Continued)
INTERCOOLER – Air-to-water. SHIPPING SKID – For domestic truck or rail.
LEVELING BOLTS STARTER – High pressure, air or gas TDI T109, inertia engaged,
LIFTING EYES – Requires 9.5 ton Working Load Limit (W.L.L.) anchor mounted with strainer and valve. Minimum supply pressure 90 psi.
shackles Maximum supply pressure 150 psi (Code 9208).
LUBRICATION – Full pressure, gear type pump. Engine mounted full TURBOCHARGERS – (2) with water-cooled bearing housing and
flow lube oil micro-fiberglass filters with mounted differential differential wastegates.
pressure gauge. Centrifugal bypass filter, engine mounted. Air/gas VIBRATION DAMPER – Viscous type.
motor driven prelube pump, requires final piping. WATER CIRCULATING SYSTEM, AUXILIARY CIRCUIT – Belt driven
MAIN BEARING THERMOCOUPLES – Seven K-type. The ESM2 water circulating high capacity pump for intercooler and lube oil
system incorporates the main bearing thermocouples as standard cooler. See S6543-36 performance curve for use with standard 10″
equipment, including high temperature shutdown safeties. diameter crankshaft pulley. Auxiliary water circuit thermostatic valve for
Thermocouples are read by the ESM2 STU (Smart Thermocouple 130° F (54° C) intercooler water temperature.
Unit) and temperature and fault information is displayed on the WATER CIRCULATING SYSTEM, ENGINE JACKET – Belt driven
ESM2 Display Panel. No customer connections required water circulating pump. Cluster type thermostatic temperature
MANIFOLDS – Exhaust, (2) water cooled. regulating valve, full flow bypass type with 165° - 170° F (74° - 77°C)
OIL COOLER – Shell and tube type, with thermostatic temperature start to open thermostats. Inlet water header connection includes
controller and pressure regulating valve. Factory mounted. single side-inlet water pump header with 6” (152 mm) flange
OIL PAN – Deep sump type. 190-gallon (719 L) capacity, including connection (Code 4293). Outlet water connection includes single 6”
filter and cooler. (152 mm) outlet connection for a 6” (152 mm) Dresser coupling,
PAINT – Oilfield orange primer. including coupling (Code 4342).
PISTONS – Aluminum with floating pin. Oil cooled. 8:1 compression
ratio.
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. June 2022
PAGE GC VHP-16
STANDARD EQUIPMENT
AIR CLEANER – Two, 3″ dry type filter with hinged rain shield and temperatures and exhaust O2 content, all accessible through the
service indicator. ESM2 interface. ESM2 continually monitors combustion
AIR FUEL RATIO CONTROL (AFR) – 2nd generation AFR2 integrates performance through individual knock sensors to provide
with ESM2 for enhanced rich-burn engine control. Utilizes fuel detonation protection. Includes adjustable oil pressure permissive
control valve between regulator and carburetor and enhanced pre- prior to start signal. Dual magnetic pick-ups are used for accurate
catalyst O2 sensor optimized for gaseous fuels for more stable engine speed monitoring. ESM2 provides diagnostics information
operation through fuel swings. Optional emPact Emission Control related to engine performance and sensor validity. Sensors meet
System adds 3-way catalyst sized for 0.15 g/bhp-hr NOx and 0.30 Canadian Standards Association Class I, Division 2, Group A, B, C,
g/bhp-hr CO or 1.0 g/bhp-hr NOx and 1.0 g/bhp-hr CO. Stainless & D (Canada & US) hazardous location
steel or carbon steel catalyst housing. emPact also adds post- ENGINE ROTATION – Counterclockwise when facing flywheel.
catalyst O2 sensor for closed-loop control, adjusting air/fuel ratio EXHAUST OUTLET – Single vertical at rear. Flexible stainless steel
based on catalyst output, and pre- and post-catalyst temperature connection with 8” (203 mm) pipe flange.
and pressure sensors for simplified maintenance and emission EXHAUST THERMOCOUPLES – 14 K-Type. ESM2 system
reporting. Standard AFR2 control system meets Canadian incorporates exhaust port and pre-turbine thermocouples as
Standards Association Class I, Division 2, Group A, B, C, & D standard equipment, including high exhaust temperature shutdown
(Canada & US) hazardous location requirements. safeties. Thermocouples are read by the ESM2 STU (Smart
ALTERNATOR - Alternator – Denso, 24V DC, 50A, Brushless, belt
Thermocouple Unit) and temperature and fault information is
driven direct off crankshaft. Includes engine mounted junction box
for connection to battery. Alternator system meets Canadian displayed on the ESM2 Display Panel. No customer connections
Standard Association Class I, Division 2, Group A, B, C & D (Canada required.
& US) hazardous location requirements (Code 3433E). FLYWHEEL – Approx. WR2 = 155000 lb-in2; with ring gear (208 teeth),
BARRING DEVICE – Manual. machined to accept two drive adapters. Machined for 22.5” (572
BATTERY BOX – Ship loose battery box designed to accommodate mm) pilot bore, 20.5” (521 mm) bolt circle, (8) 1.00”-8 tapped holes; or
two Series 31 12 VDC batteries. Includes power disconnect switch 28.875″ (733 mm) pilot bore, 27.25” (692 mm) bolt circle, (12) 0.75”-10
and 20 foot (6.1 m) cable for connection to ESM2* Power Distribution tapped holes. (Code 1161C).
Box. FLYWHEEL HOUSING – No. 00 SAE.
BEARINGS – Heavy duty, replaceable, precision type. FUEL SYSTEM – Single 3″ ANSI flange fuel inlet connection. Two
BREATHER – Self-regulating, closed system. natural gas, 4″ (102 mm) updraft carburetors and two mounted
CONNECTING RODS – Drop forged steel, rifle drilled. Fisher 99, 2” (51 mm) gas regulators. 40 – 60 psi fuel inlet pressure
CONTROL SYSTEM - Waukesha Engine System Manager 2 (ESM2*) required. Fuel control valve located between regulator and
integrates spark timing control, speed governing, detonation
carburetor replaces stepper motor.
protection, misfire detection, start-stop control, diagnostic
information, fault logging, engine safeties and AFR2 (Air/Fuel Ratio) Wire the customer-supplied fuel
control in one Engine Control Unit (ECU). One customer connection gas shutoff valve to be controlled
to the control system via a 50-foot Customer Interface harness (15.2 by ESM2. If the fuel valve is
m). ESM2 also provides a MODBUS RTU slave RS-485 connection controlled independently of ESM2, fault codes will occur when
for integration into local panels. Customer connections are required the fuel valve is not actuated in sequence with the ESM2.
to the local panel, fuel valve, and 24V DC power supply. Compatible
with Woodward load sharing module. ESM2 meets Canadian FRONT STUB SHAFT – 3.5" (89 mm) diameter x 11.75" (292 mm) long,
Standards Association Class I, Division 2, Group A, B, C, & D standard keyway 7/8" (22 mm) x 7/16" (11 mm) x 8" (203 mm) keyway.
(Canada & US) hazardous location requirements. Includes 12” Allows for customer supplied pulley sizes down to 8" (203 mm) pitch
ESM2 Display Panel. diameter to customize fan drive speed. Not compatible with Code 1140A
CRANKCASE – Integral crankcase and cylinder frame or 1140B (Code 8006).
CRANKSHAFT – Forged steel, seven main bearings, GOVERNOR - Electric throttle actuator controlled by ESM2 with
counterweighted and dynamically balanced. throttle position feedback. Governor tuning is performed using the
CYLINDERS – Removable wet type cylinder liners. ESM2 Display Panel. ESM2 includes option of a load-coming
CYLINDER HEADS – Twelve interchangeable. Four valves per feature to improve engine response to predictable step loads.
cylinder, with water cooled exhaust valve seats. Roller valve lifters IGNITION SYSTEM – 2nd generator Ignition Power Module Diagnostics
and hydraulic push rods. Flange mounted ignition coils. (IPMD2) - controlled by ESM2, with spark timing optimized for varying
DISPLAY PANEL, ESM2 – ESM2 Display Panel comes standard and is speed-load conditions. Optimized ignition energy levels, controlled by
a required part of the ESM2 system, allowing for user parameter ESM2, to maximize spark plug life and performance. The diagnostics
adjustments, fault information viewing and continuous data logging
features of IPMD2 and ESM2 can be used to help monitor spark plug
capability over the lifetime of the product. The standard ESM2 Display
Panel is a 12” (0.3m) resistive-touch full-color display, incorporating life, aiding with predictive maintenance. Shielded ignition components
service tool functionality, on-screen E-Help troubleshooting information meet Canadian Standard Association Class I, Division 2, Group A, B, C,
for ESM2 faults, and technical documentation such as manuals and D (Canada & US) hazardous location requirements.
service bulletins. The ESM2 HMI is shipped loose and mounted in the INTERCOOLER – Air-to-water.
customer control panel and meets CSA Class I, Div 2, Group A, B, C & LEVELING BOLTS
D (Canada & US) hazardous location requirements. ESM2 Display LIFTING EYES – Requires 9.5 ton Working Load Limit (W.L.L.) anchor
Panel provide Remote Monitoring & Diagnostic (RM&D) capability shackles.
for engine only. Optional data collector available for compressor
and/or balance of plant.
ENGINE MONITORING DEVICES – Factory-mounted sensors and
harnessing for pre- and post-filter lube oil pressure, oil temperature,
intake manifold temperature and pressure, crankcase pressure,
turbocharger boost pressure, jacket water temperature, post turbine
exhaust temperatures, main bearing temperatures, exhaust port
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. June 2022
PAGE GC VHP-17
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. June 2022
PAGE GC VHP-19
L7042GSI S5
L7044GSI S5
L5794GSI
L7044GSI
AIR CLEANERS
NOTE: Precleaners are recommended for applications in dusty environments or when dust conditions are
unpredictable.
2320B X X Precleaner – Heavy duty inertia separator, for standard air cleaner systems ..................................................
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. June 2022
PAGE GC VHP-20
L7042GSI S4
L7042GSI S5
L7044GSI S5
L5794GSI
L7044GSI
ELECTRICAL
3441 X X Delete Standard ESM battery box and cable. Customer is responsible for proper sizing of wire from battery to
ESM Power Distribution Box..............................................................................................................................
COOLING
4292 X X Header – Inlet water, and connections. Includes single center-inlet water pump header with 6” (152 mm)
flange connection, (2) inlet elbows, and (2) 4” (102 mm) Dresser couplings .................................................
4341 X X Connections – Water outlet. Single 6” (152 mm) flange, for remote cooling .....................................................
5022E X X Regulator – Lubricating oil level for engines with standard deep sump oil pan. Kenco model LCE with
explosion-proof electric low level SPDT safety switch and Fire Safe features. Meets CSA Class I, Division
2, Group A, B, C & D (Canada & US) requirements. For oil supply with up to 15ft. of static head. Mounted
in place of standard crankcase inspection door...............................................................................................
CONTROLS
6012 X X Four (4) BICERA – Crankcase explosion relief valves .......................................................................................
6190F X X Magnetic Pickup – Mounted. Meets Canadian Standards Association Class I, Division 2, Group A, B, C, &
D hazardous location requirements .................................................................................................................
6680 X X 15" ESM2 HMI Display Panel -- Replaces standard 12" ESM2 HMI Display Panel ..........................................
6680A X X 19" ESM2 HMI Display Panel -- Replaces standard 12" ESM2 HMI Display Panel ..........................................
MISCELLANEOUS
9974Q X X Engine/Enginator that is Customs Union Compliant (Russia, Belarus, and Kazakhstan). Includes SERIAL
NUMBER SPECIFIC Technical Passport & Safety Justification in Russian and English, Engine Operator's
Manuals (one in Russian and one in English), and EAC label on unit. Enginators include supplied
equipment manuals that are in English only. May require additional lead time, consult factory for delivery
information.........................................................................................................................................................
9974U X X Engine that is CE Mark Compliant. Includes a SERIAL NUMBER SPECIFIC Declaration of Incorporation
and Operator's Manual both in English. It is the responsibility of the entity (Packager, Distributor) placing
the complete package on the European market to ensure that the final complete package (machine) is
properly CE Marked and that the final customer is provided with the required translated
manuals. Waukesha can assist with translations at additional cost, contact Applications/Sales ................
9974X X X Required Label for Hazardous Location CSA Certification in US & Canada End Use. Adds a safety label
containing English and French language that is required to comply with the certification terms of the
equipment. Note: For end uses classified as Hazardous Locations Division 2 and in US & Canada. Contact
Application Engineering for use in other countries. .........................................................................................
9998A X X Shipping Skid – For overseas container..............................................................................................................
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. June 2022
PAGE GC VHP-21
L7042GSI S4
L7042GSI S5
L7044GSI S5
L5794GSI
L7044GSI
EXTENDED WARRANTY
10001AA X X 12-Cylinder VHP Engine Extended Warranty -- 1 Year. Extended warranty excludes wear items and includes
only warrantable items as defined in Express Limited Warranty (ELW). Must be purchased at time of
original order. If applicable, the proper deferral process and preservation as outlined in Service Bulletin
16-1855H (or most current) and WEDA 542 (or most current) must be followed or warranty extension is
void. Emission warranties for Waukesha’s emPact Emission Control System are NOT EXTENDED by
Extended Engine Warranties ............................................................................................................................
10001BB X X 12-Cylinder VHP Engine Extended Warranty -- 2 Years. Extended warranty excludes wear items and
includes only warrantable items as defined in Express Limited Warranty (ELW). Must be purchased at
time of original order. If applicable, the proper deferral process and preservation as outlined in Service
Bulletin 16-1855H (or most current) and WEDA 542 (or most current) must be followed or warranty
extension is void. Emission warranties for Waukesha’s emPact Emission Control System are NOT
EXTENDED by Extended Engine Warranties ..................................................................................................
10001CC X X 12-Cylinder VHP Engine Extended Warranty -- 3 Years. Extended warranty excludes wear items and
includes only warrantable items as defined in Express Limited Warranty (ELW). Must be purchased at
time of original order. If applicable, the proper deferral process and preservation as outlined in Service
Bulletin 16-1855H (or most current) and WEDA 542 (or most current) must be followed or warranty
extension is void. Emission warranties for Waukesha’s emPact Emission Control System are NOT
EXTENDED by Extended Engine Warranties ..................................................................................................
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. June 2022
PAGE GC VHP-22
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. June 2022
PAGE GC VHP-23
Alternator – Denso, 24V DC, 50A. Meets CSA Class I, Div 3441 Add: Delete Standard ESM2 Battery Box and Cable
3433E
2, Group A, B, C & D hazardous location requirements Regulator – Lubricating oil level. Kenco model
5022B Add:
Starter – High pressure, air or gas TDI T112, pre-engaged, LCE
9208B mounted with strainer and valve. Minimum supply pressure BICERA Valve – Crankcase explosion relief.
90 psi. Maximum supply pressure 150 psi 6012C Add:
Quantity 6
Magnetic Pickup -- Meets CSA Class I, Div 2,
Available Options on 6190G Add: Group A, B, C & D hazardous location
P9394GSI S5 GC Spec requirements
emPact Emission Control System -- Adds shipped- 15" ESM2 HMI Display Panel; replaces
loose 3-way catalyst sized to achieve 1.0 g/bhp-hr 6680 Add:
standard 12” ESM2 HMI Display Panel
NOx and 1.0 g/bhp-hr CO. Includes one 37.5 inch 19" ESM2 HMI Display Panel; replaces
1009A Add: 6680A Add:
(95.25 cm) element. Carbon steel catalyst standard 12” ESM2 HMI Display Panel
housing with 20 inch (50.8 cm) diameter inlet and
Low Pressure Pre-Engaged Air/Gas Starter
outlet flanges. Includes one flexible connection Add:
(TDI T121)
emPact Emission Control System -- Adds shipped- 9208C
loose 3-way catalyst sized to achieve 0.15 g/bhp- Code 9208B - High Pressure Pre-Engaged
Omit:
hr NOx and 0.30 g/bhp-hr CO. Includes two 37.5 Air/Gas Starter (TDI T112)
1009B Add:
inch (95.25 cm) elements. Carbon steel catalyst Dual High Pressure Pre-Engaged Air/Gas
housing with 20 inch (50.8 cm) diameter inlet and Add:
Starters (TDI T112); includes 2 starters
outlet flanges. Includes one flexible connection 9208D
emPact Emission Control System -- Adds shipped- Code 9208B - High Pressure Pre-Engaged
Omit:
loose 3-way catalyst sized to achieve 1.0 g/bhp-hr Air/Gas Starter (TDI T112)
NOx and 1.0 g/bhp-hr CO. Includes one 37.5 inch Dual Low Pressure Pre-Engaged Air/Gas
1009SA Add: Add:
(95.25 cm) element. Stainless steel catalyst
Starters (TDI T121); includes 2 starters
housing with 20 inch (50.8 cm) diameter inlet and 9208E
outlet flanges. Includes one flexible connection Code 9208B - High Pressure Pre-Engaged
Omit:
emPact Emission Control System -- Adds shipped- Air/Gas Starter (TDI T112)
loose 3-way catalyst sized to achieve 0.15 g/bhp- Engine/Enginator that is Customs Union
hr NOx and 0.30 g/bhp-hr CO. Includes two 37.5 9974Q Add:
Compliant (Russia, Belarus, and Kazakhstan)
1009SB Add: inch (95.25 cm) elements. Stainless steel
catalyst housing with 20 inch (50.8 cm) diameter 9974U Add: Engine that is CE Mark Compliant
inlet and outlet flanges. Includes one flexible CSA Certification Label for Hazardous
connection 997X Add:
Locations
Auxiliary water circuit thermostatic valve for
Add: 9998A Add: Shipping Skid - For Overseas Container
140° F (60° C) intercooler water temperature.
1106 Standard auxiliary water circuit thermostatic 16-Cylinder VHP Engine Extended Warranty --
10002AA Add:
Omit: valve for 130° F (54°C) intercooler water 1 Year
temperature 16-Cylinder VHP Engine Extended Warranty --
10002BB Add:
Omit Front End Drive Assembly: front shaft 2 Years
1140 Add:
drive/pulley assembly, pillow block and coupling 16-Cylinder VHP Engine Extended Warranty --
10002CC Add:
Omit Standard Air Cleaner – Standard engine 3 Years
2314B Add: mounted, dry type, including pad type
precleaner and service indicator
Code Description Weight lb. (kg) List Price
P2616J54 P9394GSI S5 34,000 (15,422)
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. June 2022
PAGE GC VHP-24
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. June 2022
PAGE GC VHP-25
P9394GSI S5
IGNITION
3441 X Delete Standard ESM battery box and cable. Customer is responsible for proper sizing of wire from battery to
ESM2 Power Distribution Box. ...................................................................................................................................
LUBRICATION
5022B X Regulator – Lubricating oil level. Kenco model LCE with explosion-proof electric low level SPDT safety switch and
Fire Safe features. Meets CSA Class I, Division 2, Group A, B, C & D (Canada & US) requirements. For oil
supply with up to 15ft. of static head. Mounted in place of standard crankcase inspection door. ...........................
6012C X BICERA Valve – Crankcase explosion relief. Quantity 6 .............................................................................................
CONTROLS
6190G X Magnetic Pickup - Mounted. Meets Canadian Standards Association Class I, Division 2, Group A, B, C, & D
hazardous location requirements ...............................................................................................................................
6680 X 15" ESM2 HMI Display Panel -- Replaces standard 12" ESM2 HMI Display Panel. ..................................................
6680A X 19" ESM2 HMI Display Panel -- Replaces standard 12" ESM2 HMI Display Panel....................................................
MISCELLANEOUS
9974Q X Engine/Enginator that is Customs Union Compliant (Russia, Belarus, and Kazakhstan). Includes SERIAL
NUMBER SPECIFIC Technical Passport & Safety Justification in Russian and English, Engine Operator's
Manuals (one in Russian and one in English), and EAC label on unit. Enginators include supplied equipment
manuals that are in English only. May require additional lead time, consult factory for delivery information ........
9974U X Engine that is CE Mark Compliant. Includes a SERIAL NUMBER SPECIFIC Declaration of Incorporation and
Operator's Manual both in English. It is the responsibility of the entity (Packager, Distributor) placing the
complete package on the European market to ensure that the final complete package (machine) is properly CE
Marked and that the final customer is provided with the required translated manuals. Waukesha can assist with
translations at additional cost, contact Applications/Sales ........................................................................................
9974X X Required Label for Hazardous Location CSA Certification in US & Canada End Use. Adds a safety label
containing English and French language that is required to comply with the certification terms of the equipment.
Note: For end uses classified as Hazardous Locations Division 2 and in US & Canada. Contact Application
Engineering for use in other countries .......................................................................................................................
9998A X Shipping Skid – For overseas container .......................................................................................................................
EXTENDED WARRANTY
10002AA X 16-Cylinder VHP Engine Extended Warranty -- 1 Year. Extended warranty excludes wear items and includes only
warrantable items as defined in Express Limited Warranty (ELW). Must be purchased at time of original order. If
applicable, the proper deferral process and preservation as outlined in Service Bulletin 16-1855H (or most
current) and WEDA 542 (or most current) must be followed or warranty extension is void. Emission warranties
for Waukesha’s emPact Emission Control System are NOT EXTENDED by Extended Engine Warranties ......... .
10002BB X 16-Cylinder VHP Engine Extended Warranty -- 2 Years. Extended warranty excludes wear items and includes
only warrantable items as defined in Express Limited Warranty (ELW). Must be purchased at time of original
order. If applicable, the proper deferral process and preservation as outlined in Service Bulletin 16-1855H (or
most current) and WEDA 542 (or most current) must be followed or warranty extension is void. Emission
warranties for Waukesha’s emPact Emission Control System are NOT EXTENDED by Extended Engine
Warranties. ..................................................................................................................................................................
10002CC X 16-Cylinder VHP Engine Extended Warranty -- 3 Years. Extended warranty excludes wear items and includes
only warrantable items as defined in Express Limited Warranty (ELW). Must be purchased at time of original
order. If applicable, the proper deferral process and preservation as outlined in Service Bulletin 16-1855H (or
most current) and WEDA 542 (or most current) must be followed or warranty extension is void. Emission
warranties for Waukesha’s emPact Emission Control System are NOT EXTENDED by Extended Engine
Warranties. ..................................................................................................................................................................
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. June 2022
PAGE ENG 275GL-1
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars, June 2022
PAGE ENG 275GL-2
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars, June 2022
PAGE ENG 275GL-3
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars, June 2022
PAGE ENG 275GL-4
16V275GL+ ESM2
FUEL SYSTEMS
2060 X X Fuel System for natural gas with heating values from 700-850 BTU/SCF.
Includes modified air/fuel mixer and ESM calibration. Available only on
P2916J2, J3 and P2912J2,J3.......................................................................
2060A X X Fuel System for natural gas with heating values from 600-750 BTU/SCF.
Includes modified air/fuel mixer, turbocharger, and ESM calibration.
Available only on P2916J2, J3 and P2912J2, J3 ........................................
AIR CLEANERS
2300A X X X X Air Filter-Dry panel type with cover for indoor or outdoor applications shipped
loose. Includes 2. Connection location is “back out”. Color-machinery gray
........................................................................................................................
2300B X X X X Heavy Duty Air Filter – Dry panel type for indoor or outdoor applications.
Includes heavy duty inertia separator. Shipped loose. Connection is “back
out”. Color – machinery grey. Includes 2. .....................................................
NOTE: For starting and/or operation below 0° F (-18° C) consult S9064-4 in
the Technical Data Book under “Starting”.
NOTE: Outdoor application of 2300B require customer provided rain cover.
2399 X Intake Air Flex Connection – Air Intake Flexes, 10” (254mm) ANSI flanges
x 11.8” (300mm) long. (Includes 2, 1 per bank). Suitable for rigidly
mounted units only. Not for use with vibration isolators ..............................
2400 X X X Intake Air Flex Connection – Air Intake Flexes, 12” (305mm) ANSI flanges
x 13.8” (352mm) long. (Includes 2, 1 per bank). ..........................................
LUBRICATION
5040 X X X X Air Driven Pre-Lube Pump – Engine mounted, air/gas motor-driven prelube
pump. Pump motor: frame size 182C, Rated 4.15HP @ 3000 rpm, air
consumption at maximum HP 181 SCFM Color-machinery gray .................
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. June 2022
PAGE ENG 275GL-6
16V275GL+ ESM2
Code 275GL+ ACCESSORIES
CONTROLS
6680 X X X X 15" ESM2HMI Display Panel --Replaces standard 12" ESM2HMI Display
Panel .............................................................................................................
6680A X X X X 19” ESM2 HMI Display Panel --Replaces standard 12" ESM2HMI Display
Panel .............................................................................................................
6690A X X X X 25' (7.6m) ESM2 Customer Interface Harness for customer connections,
local control and HMI on ESM2-equipped engines. Replaces 50’ (15.2m)
ESM2 Customer Interface Harness .............................................................
6690B X X X X 100’ (30.4m) ESM2 Customer Interface Harness for customer connections,
local control and HMI on ESM2-equipped engines. Replaces 50’ (15.2m)
ESM2 Customer Interface Harness .............................................................
6690C X X X X 200’ (60.8 m) ESM2 Customer Interface Harness for customer
connections, local control and HMI on ESM2-equipped engines.
Replaces 50’ (15.2m) ESM2 Customer Interface Harness .........................
EXHAUST
7200A X Exhaust Flexes, 8” (203 mm) ANSI flange to 14″ (356 mm) ANSI flange
(Includes 2, 1 per bank), shipped loose. Only applicable to P2912J2,J3 .
7201C X Exhaust Y – Transition, Two 14” (356 mm) ANSI flanges to a single 22″
(559 mm) ANSI flanged outlet. Includes code 7200A. Shipped loose.
Only applicable to P2912J2,J3 .....................................................................
7200B X X X Exhaust Flexes, 14″ (356 mm) ANSI flanges x 13″ (330 mm) long. (Includes
2, 1 per bank), shipped loose. P2812J2, P2816J2, P2916J2 .....................
7201B X X X Exhaust Y – Transition. Two 14″ (356 mm) ANSI flanges to a single 28″ (710
mm) ANSI flange. Includes code 7200B. Shipped Loose. P2812J2,
P2816J2, P2916J2........................................................................................
STUB SHAFT
8000B X X X X Front Stub Shaft – 200 HP maximum (12.00″ lg. X 3.43″ dia.) .......................
8010 X X X X Partial Front Stub Shaft – Provides flange connection for packager
supplied front stub shaft. 160 mm bolt circle, (6) 7/8 UNC holes with 120
mm pilot .........................................................................................................
STARTING EQUIPMENT
Starter – TDI 112V High Pressure (150 psi max) air or gas, includes 2,
9209 X X replaces 1 standard starter ...........................................................................
Starter – TDI 121 Low Pressure (90 psi max) air or gas, includes 2,
9209A X X replaces 1 standard starter ...........................................................................
X X Starter – TDI 121 Low Pressure (90 psi max) air or gas, includes 2,
9209B replaces 2 standard starters .........................................................................
MISCELLANEOUS
9801 X X X X Engine Lifting Device – Spreader bar required for proper lifting of engine.
Use this code for the purchase of the lifting device. Lifting eyes are
included with this lifting device. ...................................................................
9974Q X X X X Engine/Enginator that is Customs Union Compliant (Russia, Belarus, and
Kazakhstan). Includes SERIAL NUMBER SPECIFIC Technical
Passport & Safety Justification in Russian and English, Engine
Operator's Manuals (one in Russian and one in English), and EAC label
on unit. Enginators include supplied equipment manuals that are in
English only. May require additional lead time, consult factory for
delivery information. ......................................................................................
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. June 2022
PAGE ENG 275GL-7
16V275GL+ ESM2
Code 275GL+ ACCESSORIES
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. June 2022
PAGE ENG 275GL-8
16V275GL+ ESM2
Code 275GL+ ACCESSORIES
SERVICE PARTS
10020A X X X X Tool Kit - Includes all specialty tooling required to service the 275GL+
engine ............................................................................................................
10020B X X X X Commissioning Spares - Includes spare spark plugs, admission valve
repair kits, spare oil filters, and inertial oil filter gaskets .............................
10020C X X Emergency Spares – For application to the 275GL+ with ESM2. Includes:
spare wastegate, bypass valve assembly. Water pump rebuild kits,
cylinder head, piston/ring/liner assembly, spare temperature, pressure
and speed transducers for all locations on engine. Ignition module &
coils, engine control unit, NOx sensor, exhaust compensators. Gas
regulators and solenoid valves, various gaskets and hardware.
P2812J2,J3 P2816J2, J3 ............................................................................
10020D X X Emergency Spares – For application to the 275GL+ with ESM2. Includes:
spare wastegate, bypass valve assembly. Water pump rebuild kits,
cylinder head, piston/ring/liner assembly, spare temperature, pressure
and speed transducers for all locations on engine. Ignition module &
coils, engine control unit, NOx sensor, exhaust compensators. Gas
regulators and solenoid valves, various gaskets and hardware.
P2916J2, J3 ..................................................................................................
10020E X Emergency Spares – For application to the 275GL+ with ESM2. Includes:
spare wastegates, bypass valve assembly. Water pump rebuild kits,
cylinder head, piston/ring/liner assembly, spare temperature, pressure
and speed transducers for all locations on engine. Ignition module &
coils, engine control unit, NOx sensor, exhaust compensators. Gas
regulators and solenoid valves, various gaskets and hardware.
P2912J2, J3 ..................................................................................................
DISCLAIMER
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. June 2022
PAGE ENG VHP-1
VHP* Engines for Variable Speed Applications (Gas Compression, Mechanical Drive etc.)
MODEL ENGINE CODE LIST PRICE (JUNE 2022)
F3514GSI (w/ESM2, includes AFR2) P1610J16
F3524GSI (w/ESM2, includes AFR2) P1610J7
L5774LT (w/ESM) P2212J19
L5794LT (w/ESM) P2212J15
L5794GSI (w/ESM2, includes AFR2) P2212J14
L7042GSI S4 (w/ESM2, includes AFR2) P2212J27
L7042GSI S5 (w/ESM2, includes AFR2) P2212J52
L7044GSI (w/ESM2, includes AFR2) P2212J13
L7044GSI S5 (w/ESM2, includes AFR2) P2212J54
P9394GSI S5 (w/ESM2 & AFR2) P2616J5
Engines shown above in Variable Speed section have ability to change speeds as required for gas compression and mechanical drive
applications
Engines purchased with optional emPact Emission Control System include 3-way catalyst with capability to achieve:
Housings are available in either carbon steel or stainless steel (“S” suffix)
Engines shown above in Constant Speed section run at idle and rated speed only as required for Power Generation applications; speed turndown
is not available in these configurations
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. June 2022
PAGE ENG VHP-2
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. June 2022
PAGE ENG VHP-3
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. June 2022
PAGE ENG VHP-4
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. June 2022
PAGE ENG VHP-5
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. June 2022
PAGE ENG VHP-6
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. June 2022
PAGE ENG VHP-8
F3514GSI
F3524GSI
Code MODEL F3514, F3524 ACCESSORIES
1140A X Front Crankshaft Pulley – Six C section drive grooves, pitch diameter 9.60 inches. Not compatible with
Code 8006. ....................................................................................................................................................
1140B X Front Crankshaft Pulley – Six 5V section drive grooves, pitch diameter 9.60 inches. Not compatible with
Code 8006. ....................................................................................................................................................
FUEL SYSTEMS
NOTE: The following 2021 and 2021A Codes require a higher upstream fuel pressure into customer supplied
fuel pressure regulator.
2021 X Low Fuel Pressure System –Allows for a minimum main fuel supply pressure of 15 inches (381 mm) of
water column at the inlet of the Fisher 133L regulator. There is a maximum distance of 3 ft between the
Fisher 133L regulator outlet and the engine fuel inlet. One Fisher 133L regulator shipped loose. Natural
gas fuel only. Note: Crankcase ventilation system required. Consult S7232–118 for requirements. For
continuous duty. Single fuel applications only. Not compatible with emPact Emission Control System or
ESM2; engine will be built with Waukesha AFR system and ESM. ............................................................
2021A X Low Fuel Pressure System –Allows for a minimum main fuel supply pressure of 15 inches (381 mm) of
water column at the inlet of the Fisher 133L regulator. There is a maximum distance of 3 ft between the
Fisher 133L regulator outlet and the engine fuel inlet. One Fisher 133L regulator shipped loose. Natural
gas fuel only. Note: Crankcase ventilation system required. Consult S7232–118 for requirements. For
peak shaving or stand-by duty. Single fuel applications only. Not compatible with emPact Emission
Control System or ESM2; engine will be built with Waukesha AFR system and ESM. ..............................
AIR CLEANERS
NOTE: Precleaners are recommended for applications in dusty environments, or when dust conditions are
unpredictable.
2320B X Precleaner – Heavy duty inertia separator, for standard air cleaner. .............................................................
ELECTRICAL
3433E X Alternator – Denso, 24V DC, 50A, Brushless, belt driven direct off crankshaft. Includes engine mounted
junction box for connection to battery. Alternator system meets Canadian Standard Association Class I,
Division 2, Group A, B, C & D (Canada & US) hazardous location requirements. ............................................
3436 X AC/DC Power Supply – Lambda Model LZS-1000-3 with AC input 85-132/170-265 VAC, 47-440 Hz. 24V
DC output 50 amps at 104°F (40°C), 48 amps at 122°F (50°C), 40 amps at 140°F (60°C), and 30 amps
at 160°F (71°C), CSA950, UL1950, EN60950, CE Mark ..............................................................................
3441 X Delete Standard ESM battery box and cable. Customer is responsible for proper sizing of wire from battery
to ESM Power Distribution Box. .....................................................................................................................
COOLING
4282 X Preheater – Water jacket heating. 2500 watt, 240 volt AC, with thermostat ..................................................
LUBRICATION
5004 X Lube Oil Filter – Duplex, full flow type with valve and differential pressure gauge. Replaces standard lube
oil filter. Ship loose. Not compatible with Code 5113. ..................................................................................
5022 X Regulator – Lubricating oil level. Kenco model LCE with explosion-proof electric low level SPDT safety
switch and Fire Safe features. Meets CSA Class I, Division 2, Group B, C, & D requirements. For oil
supply with up to 15ft. of static head. Mounted in place of standard crankcase inspection door ..............
5105 X Omit flexible connections for standard lube oil filter and provide 1.5”- 11.5 NPT threaded inlet to lube oil
strainer ...........................................................................................................................................................
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. June 2022
PAGE ENG VHP-9
F3514GSI
F3524GSI
Code MODEL F3514, F3524 ACCESSORIES
5113 X Waukesha Cleanable Full Flow Oil Filter Elements replaces standard depth-type elements. Requires
standard centrifugal bypass oil filter and standard full flow oil filter canister. Elements shipped loose. Not
compatible with Code 5004 ..........................................................................................................................
5229B X Lubricating System – Electric prelube pump for prelube and post lube for automatic or remote start
applications that have time to prelube prior to starting engine. Does not include relief valve which is
required for continuous operation. Includes 115V AC, 60 HZ, single phase motor driven prelube pump,
and motor starter. Omits standard air/gas prelube motor drive system. .....................................................
5229D X Lubricating System – Electric prelube pump for prelube and post lube for automatic or remote start
applications that have time to prelube prior to starting engine. Does not include relief valve which is
required for continuous operation. Includes 208-230V AC, 50/60Hz, single phase motor driven prelube
pump, and motor starter. Omits standard air/gas prelube motor drive system. ..........................................
5235 X Prelube Pump – For electric motor drive. Includes piping between the pump and engine. Does not include
electric motor or other electrical components. Does not include relief valve for continuous pump
operation. Omits standard air/gas prelube motor. The pump rotation is counterclockwise looking at motor
end of pump. Motor to meet the following; frame size NEMA 56C, ¾ HP, 950-1200 RPM........................
CONTROLS (General)
6012 X Valve – BICERA crankcase explosion relief. Four (4) required ......................................................................
6190F X Magnetic Pickup - Mounted. Meets Canadian Standards Association Class 1, Division 2, Group A, B, C,
& D hazardous location requirements. .........................................................................................................
POWER TAKE-OFF
8000A X Rear Stub Shaft - 4.75" (121mm) diameter x 10.50" (267mm) long, 1.25" (32mm) x 0.63" x 9" (229mm) keyway
with key, for attachment to standard PTO flywheel. Not for side load applications. ................................................
8006 X Front Stub Shaft – 3.5" (89 mm) diameter x 11.75" (292 mm) long, standard keyway 7/8" (22 mm) x 7/16" (11
mm) x 8" (203 mm) keyway. Allows for customer supplied pulley sizes down to 8" (203 mm) pitch diameter to
customize fan drive speed. Not compatible with Code 1140A or 1140B ...................................................................
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. June 2022
PAGE ENG VHP-10
F3514GSI
F3524GSI
Code MODEL F3514, F3524 ACCESSORIES
MISCELLANEOUS
9974Q X Engine/Enginator that is Customs Union Compliant (Russia, Belarus, and Kazakhstan). Includes SERIAL
NUMBER SPECIFIC Technical Passport & Safety Justification in Russian and English, Engine
Operator's Manuals (one in Russian and one in English), and EAC label on unit. Enginators include
supplied equipment manuals that are in English only. May require additional lead time, consult factory
for delivery information..................................................................................................................................
9974U X Engine that is CE Mark Compliant. Includes a SERIAL NUMBER SPECIFIC Declaration of Incorporation
and Operator's Manual both in English. It is the responsibility of the entity (Packager, Distributor) placing
the complete package on the European market to ensure that the final complete package (machine) is
properly CE Marked and that the final customer is provided with the required translated
manuals. Waukesha can assist with translations at additional cost, contact Applications/Sales ............
9974X X Required Label for Hazardous Location CSA Certification in US & Canada End Use. Adds a safety label
containing English and French language that is required to comply with the certification terms of the
equipment. Note: For end uses classified as Hazardous Locations Division 2 and in US & Canada.
Contact Application Engineering for use in other countries. .......................................................................
9998A X Shipping Skid – For overseas container ..........................................................................................................
EXTENDED WARRANTY
10000AA X 6-Cylinder VHP Engine Extended Warranty -- 1 Year. Extended warranty excludes wear items and
includes only warrantable items as defined in Express Limited Warranty (ELW). Must be purchased at
time of original order. If applicable, the proper deferral process and preservation as outlined in Service
Bulletin 16-1855H (or most current) and WEDA 542 (or most current) must be followed or warranty
extension is void. Emission warranties for Waukesha’s emPact Emission Control System are NOT
EXTENDED by Extended Engine Warranties ..............................................................................................
10000BB X 6-Cylinder VHP Engine Extended Warranty -- 2 Years. Extended warranty excludes wear items and
includes only warrantable items as defined in Express Limited Warranty (ELW). Must be purchased at
time of original order. If applicable, the proper deferral process and preservation as outlined in Service
Bulletin 16-1855H (or most current) and WEDA 542 (or most current) must be followed or warranty
extension is void. Emission warranties for Waukesha’s emPact Emission Control System are NOT
EXTENDED by Extended Engine Warranties ..............................................................................................
10000CC X 6-Cylinder VHP Engine Extended Warranty -- 3 Years. Extended warranty excludes wear items and
includes only warrantable items as defined in Express Limited Warranty (ELW). Must be purchased at
time of original order. If applicable, the proper deferral process and preservation as outlined in Service
Bulletin 16-1855H (or most current) and WEDA 542 (or most current) must be followed or warranty
extension is void. Emission warranties for Waukesha’s emPact Emission Control System are NOT
EXTENDED by Extended Engine Warranties ..............................................................................................
DISCLAIMER
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. June 2022
PAGE ENG VHP-11
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. June 2022
PAGE ENG VHP-12
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. June 2022
PAGE ENG VHP-13
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. June 2022
PAGE ENG VHP-14
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. June 2022
PAGE ENG VHP-15
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. June 2022
PAGE ENG VHP-16
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. June 2022
PAGE ENG VHP-17
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. June 2022
PAGE ENG VHP-18
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. June 2022
PAGE ENG VHP-19
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. June 2022
PAGE ENG VHP-20
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. June 2022
PAGE ENG VHP-21
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. June 2022
PAGE ENG VHP-22
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. June 2022
PAGE ENG VHP-23
L7042GSI S4
L7042GSI S5
L7044GSI S5
L5794GSI
L7044GSI
L5774LT
L5794LT
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. June 2022
PAGE ENG VHP-24
L7042GSI S4
L7042GSI S5
L7044GSI S5
L5794GSI
L7044GSI
L5774LT
L5794LT
Code MODEL L5774, L5794, L7042, L7044 ACCESSORIES
FUEL SYSTEMS
Any installation using landfill gas as fuel must
dehydrate the gas by refrigeration followed by
reheating to remove significant amounts of
halogen compounds, siloxanes and water. Reference WAUKESHA Gaseous Fuel
Specification. S7884–7, in the Waukesha Engine General Technical Data Book.
NOTE: The following 2020, 202A, 2020B, 2021 and 2021B Codes require a higher
upstream fuel pressure into customer supplied fuel pressure regulators.
2020 X Low Fuel Pressure System – Natural gas fuel. Allows for main fuel supply pressure
regulated down to 6 inches (152 mm) of water column at the engine fuel connections.
Requires main fuel supply regulator. ..............................................................................
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. June 2022
PAGE ENG VHP-25
L7042GSI S4
L7042GSI S5
L7044GSI S5
L5794GSI
L7044GSI
L5774LT
L5794LT
Code MODEL L5774, L5794, L7042, L7044 ACCESSORIES
2020A X Low Fuel Pressure System – Landfill gas fuel with LHV of 400 – 550 Btu/ft3. Allows for
main fuel supply pressure regulated down to 6 inches (152 mm) of water column at
the engine fuel connections. Includes valves and main and rod bearings designed for
corrosion resistance. Requires Code 1107 High Temperature Thermostats. Consult
factory for delivery lead times..........................................................................................
2020B X Low Fuel Pressure System – Digester gas fuel with LHV of 550 – 650 Btu/ft3. Allows for
main fuel supply pressure regulated down to 6 inches (152 mm) of water column at
the engine fuel connections. Requires main fuel supply regulator. Requires Code
1107 High Temperature Thermostats. Consult factory for delivery lead times. ............
2021 X Low Fuel Pressure System – Allows for a minimum main fuel supply pressure of 15
inches (381 mm) of water column at the inlet of the Fisher 133L regulator. There is a
maximum distance of 3 ft between the Fisher 133L regulator outlet and the engine
fuel inlet. Two Fisher 133L regulators shipped loose. Natural gas fuel only. Not
compatible with emPact Emission Control System or ESM2; engine will be built with
Waukesha AFR system and ESM. ..................................................................................
NOTE: For continuous duty. Single fuel applications only.
2021D X Low Fuel Pressure System for Series Five – Allows for a minimum main fuel supply
pressure of 1.7 PSIG (11.7 kPa) at the inlet of each of the two (2) engine-mounted
fuel pressure regulators. Fuel inlets located above flywheel. Requires fuel with a
minimum LHV of 800 Btu/ft3 (31.4 MJ/m3). Two (2) fuel control valves are engine-
mounted. Two (2) high capacity turbochargers to accommodate flow of fuel. Includes
ESM2 control system with integrated AFR2 air/fuel ratio control. Compatible with
emPact Emission Control System. Applies to 7044GSI S5 (P5212J54) and 7042GSI
S5 (P5212J52) in 50 hz power generation applications only ........................................
2200 X X Low Btu Fuel System -- Fuel system for fuels with heating values from 700-850 Btu/ft3.
Includes modified carburetor and spring. .......................................................................
AIR CLEANERS
NOTE: Precleaners are recommended for applications in dusty environments or when
dust conditions are unpredictable.
2320B X X X X Precleaner – Heavy duty inertia separator, for standard air cleaner.................................
2350 X X X X Air Cleaner Housing Modification for Remote Air Intakes -- Modified air cleaner to allow
intake air to be piped from outside enclosure while leaving air filters on engine. Required
on 12-cylinder GSI, LT, and GL engines for proper operation of breather system when
using remote air intakes. Provides 5.5-inch (139.7 mm) diameter connection to flexible
hose for servicing of air filter element without disconnecting customer piping. Cannot be
used with Code 2320B or on engines with draw-through fuel systems ...........................
ELECTRICAL
3433E X X X X Alternator – Denso, 24V DC, 50A, Brushless, belt driven direct off crankshaft. Includes
engine mounted junction box for connection to battery. Alternator system meets
Canadian Standard Association Class I, Division 2, Group A, B, C & D (Canada & US)
hazardous location requirements. ..................................................................................
3436 X X X X AC/DC Power Supply – Lambda Model LZS-1000-3 with AC input 85-132/170-265 VAC,
47-440 Hz. 24V DC output 50 amps at 104°F (40°C), 48 amps at 122°F (50°C), 40
amps at 140°F (60°C), and 30 amps at 160°F (71°C), CSA950, UL1950, EN60950, CE
Mark ..................................................................................................................................
3441 X X X X Delete Standard ESM battery box and cable. Customer is responsible for proper sizing of
wire from battery to ESM Power Distribution Box.............................................................
COOLING
4282 X X X Preheater – Water jacket heating. (2) 2500 watt, 240 volt AC, with thermostat. ..............
4282A X X X Preheater - Water Jacket Heating. (2) 4500 watt, 240 volt AC, with thermostat. .............
4285 X X X Jacket Water Heater Canister – Includes all engine piping. Packager supplies heating element.
..........................................................................................................................................................
4292 X X X X Header – Inlet water, and connections. Includes single center-inlet water pump header with
6” (152 mm) flange connection, (2) inlet elbows, and (2) 4” (102 mm) Dresser couplings...
4293 X X X X Header – Inlet water, and connections. Includes single side-inlet water pump header with 6”
(152 mm) flange connection, (2) inlet elbows, and (2) 4” (102 mm) Dresser couplings .......
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. June 2022
PAGE ENG VHP-26
L7042GSI S4
L7042GSI S5
L7044GSI S5
L5794GSI
L7044GSI
L5774LT
L5794LT
Code MODEL L5774, L5794, L7042, L7044 ACCESSORIES
4341 X X X X Connections – Water outlet. Single 6” (152 mm) flange, for remote cooling ....................
4342 X X X X Connections – Water outlet. Single 6” (152 mm) outlet connection for a 6” (152 mm)
Dresser coupling, including coupling. Cannot be used with Code 7301 .......................
LUBRICATION
5005 X X X X Base Style Oil Pan – Replaces deep sump style oil pan. 90-gal (340 L) lube oil capacity
includes pan, filters, cooler and volume vessel. Lube oil volume vessel shipped loose.
Single fuel inlet not available with base style oil pan......................................................
NOTE: Please refer to S1015-30 (or latest revision) for recommended oil change intervals.
5022E X X X X Regulator – Lubricating oil level for engines with standard deep sump oil pan. Kenco
model LCE with explosion-proof electric low level SPDT safety switch and Fire Safe
features. Meets CSA Class I, Division 2, Group A, B, C & D (Canada & US)
requirements. For oil supply with up to 15ft. of static head. Mounted in place of
standard crankcase inspection door ...............................................................................
5022F X X X X Regulator – Lubricating oil level for engines with shallow base-style oil pan. Kenco
model LCE with explosion-proof electric low level SPDT safety switch and Fire Safe
features. Meets CSA Class I, Division 2, Group A, B, C & D (Canada & US)
requirements. For oil supply with up to 15ft. of static head. Mounted in place of
standard crankcase inspection door. Requires Option Code 5005 .............................
5229B X X X X Lubricating System – Electric prelube pump for prelube and post lube for automatic or
remote start applications that have time to prelube prior to starting engine. Does not
include relief valve which is required for continuous operation. Includes 115V AC,
60Hz, single phase motor driven pre-lube pump, motor starter. Omits standard air/gas
prelube motor drive system. ............................................................................................
5229D X X X X Lubricating System – Electric prelube pump for prelube and post lube for automatic or
remote start applications that have time to prelube prior to starting engine. Does not
include relief valve which is required for continuous operation. Includes 208-230V AC,
50/60Hz, single phase motor driven pre-lube pump, motor starter. Omits standard
air/gas prelube motor drive system. ................................................................................
5235 X X X X Prelube Pump – For electric motor drive. Includes piping between the pump and engine.
Does not include electric motor or other electrical components. Does not include relief
valve for continuous pump operation. Omits standard air/gas prelube motor. The
pump rotation is clockwise looking at motor end of pump. Motor to meet the following:
frame size NEMA 56C, ¾ HP, 950-1200 RPM ...............................................................
CONTROLS (General)
6012 X X X X Four (4) BICERA – Crankcase explosion relief valves ......................................................
6190F X X X X Magnetic Pickup - Mounted. Meets Canadian Standards Association Class 1, Division
2, Group A, B, C, & D hazardous location requirements................................................
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. June 2022
PAGE ENG VHP-27
L7042GSI S4
L7042GSI S5
L7044GSI S5
L5794GSI
L7044GSI
L5774LT
L5794LT
Code MODEL L5774, L5794, L7042, L7044 ACCESSORIES
6650D X X X ESM Customer Interface and Option Harnesses – Replaces standard 25-foot (7.6 m)
customer interface and option harnesses with 50 foot (15 m) harnesses. Applies to
L5774/94LT, L7044G, or when Code 2021 or 2021A is selected ..................................
6650L X X X 200-foot (60 m) ESM Customer Interface & Option Harnesses - Replaces standard 25-
foot (7.6m) Customer Interface & Option Harnesses. Applies to L5774/94LT, L7044G,
or when Code 2021 or 2021A is selected .......................................................................
6650M X X X 200-foot (60 m) Exhaust Thermocouple Harness - Replaces standard 25-foot (7.6m)
Exhaust Thermocouple harness. Applies to L5774/94LT, L7044G, or when Code
2021 or 2021A is selected ...............................................................................................
6650N X X X 200-foot (60 m) Main Bearing Thermocouple Harness - Replaces standard 25-foot (7.6
m) main bearing thermocouple harness. Requires Code 6020. Applies to L5774/94LT,
L7044G, or when Code 2021 or 2021A is selected ........................................................
6660 X X ESM Display panel - Waukesha pre-programmed display panel for digital engine
parameter readout including engine shutdown snapshot. Simple installation with
MODBUS RS485 communications including built-in MODBUS pass-thru capabilities
allowing seamless package controller communications. 128 x 64 graphic backlit
display with key pad navigation, Meets CSA Class I, Div 2, Groups B, C, and D.
Available in English only (Shipped loose). Applies to L5774/94LT, L7044G, or when
Code 2021 or 2021A is selected .....................................................................................
POWER TAKE-OFF
8000A X X X X Rear Stub Shaft - 4.75" (121mm) diameter x 10.50" (267mm) long, 1.25" (32mm) x 0.63"
x 9" (229mm) keyway with key, for attachment to standard PTO flywheel. Not for side
load applications. ..............................................................................................................
8006 X X X X Front Stub Shaft – 3.5" (89 mm) diameter x 11.75" (292 mm) long, standard keyway
7/8" (22 mm) x 7/16" (11 mm) x 8" (203 mm) keyway. Allows for customer supplied
pulley sizes down to 8" (203 mm) pitch diameter to customize fan drive speed. Not
compatible with Code 1140A or 1140B...........................................................................
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. June 2022
PAGE ENG VHP-28
L7042GSI S4
L7042GSI S5
L7044GSI S5
L5794GSI
L7044GSI
L5774LT
L5794LT
Code MODEL L5774, L5794, L7042, L7044 ACCESSORIES
MISCELLANEOUS
9974Q X X X X Engine/Enginator that is Customs Union Compliant (Russia, Belarus, and
Kazakhstan). Includes SERIAL NUMBER SPECIFIC Technical Passport & Safety
Justification in Russian and English, Engine Operator's Manuals (one in Russian
and one in English), and EAC label on unit. Enginators include supplied equipment
manuals that are in English only. May require additional lead time, consult factory for
delivery information ..........................................................................................................
9974U X X X X Engine that is CE Mark Compliant. Includes a SERIAL NUMBER SPECIFIC Declaration
of Incorporation and Operator's Manual both in English. It is the responsibility of the
entity (Packager, Distributor) placing the complete package on the European market
to ensure that the final complete package (machine) is properly CE Marked and that
the final customer is provided with the required translated manuals. Waukesha can
assist with translations at additional cost, contact Applications/Sales ..........................
9974X X X X X Required Label for Hazardous Location CSA Certification in US & Canada End Use.
Adds a safety label containing English and French language that is required to comply
with the certification terms of the equipment. Note: For end uses classified as
Hazardous Locations Division 2 and in US & Canada. Contact Application
Engineering for use in other countries. ...........................................................................
9998A X X X X Shipping Skid – For overseas container ............................................................................
EXTENDED WARRANTY
10001AA X X X X 12-Cylinder VHP Engine Extended Warranty -- 1 Year. Extended warranty excludes
wear items and includes only warrantable items as defined in Express Limited
Warranty (ELW). Must be purchased at time of original order. If applicable, the proper
deferral process and preservation as outlined in Service Bulletin 16-1855H (or most
current) and WEDA 542 (or most current) must be followed or warranty extension is
void. Emission warranties for Waukesha’s emPact Emission Control System are NOT
EXTENDED by Extended Engine Warranties.................................................................
10001BB X X X X 12-Cylinder VHP Engine Extended Warranty -- 2 Years. Extended warranty excludes
wear items and includes only warrantable items as defined in Express Limited
Warranty (ELW). Must be purchased at time of original order. If applicable, the proper
deferral process and preservation as outlined in Service Bulletin 16-1855H (or most
current) and WEDA 542 (or most current) must be followed or warranty extension is
void. Emission warranties for Waukesha’s emPact Emission Control System are NOT
EXTENDED by Extended Engine Warranties.................................................................
10001CC X X X X 12-Cylinder VHP Engine Extended Warranty -- 3 Years. Extended warranty excludes
wear items and includes only warrantable items as defined in Express Limited
Warranty (ELW). Must be purchased at time of original order. If applicable, the proper
deferral process and preservation as outlined in Service Bulletin 16-1855H (or most
current) and WEDA 542 (or most current) must be followed or warranty extension is
void. Emission warranties for Waukesha’s emPact Emission Control System are NOT
EXTENDED by Extended Engine Warranties.................................................................
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. June 2022
PAGE ENG VHP-29
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. June 2022
PAGE ENG VHP-30
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. June 2022
PAGE ENG VHP-31
Code
P9394GSI S5
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. June 2022
PAGE ENG VHP-32
Code
P9394GSI S5
FUEL SYSTEMS
2200 X Low Btu Fuel System -- Fuel system for fuels with heating values from 700-850 Btu/ft3. Includes modified
carburetor and spring. ..................................................................................................................................................
ELECTRICAL
3433E X Alternator – Denso, 24V DC, 50A, Brushless, belt driven direct off crankshaft. Includes engine mounted
junction box for connection to battery. Alternator system meets Canadian Standard Association Class
I, Division 2, Group A, B, C & D (Canada & US) hazardous location requirements. ..............................
3436 X AC/DC Power Supply – Lambda Model LZS-1000-3 with AC input 85-132/170-265 VAC, 47-440 Hz.
24V DC output 50 amps at 104°F (40°C), 48 amps at 122°F (50°C), 40 amps at 140°F (60°C), and
30 amps at 160°F (71°C), CSA950, UL1950, EN60950, CE Mark ...........................................................
3441 X Delete Standard ESM battery box and cable. Customer is responsible for proper sizing of wire from
battery to ESM Power Distribution Box. .....................................................................................................
LUBRICATION
5022B X Regulator – Lubricating oil level. Kenco model LCE with explosion-proof electric low level SPDT safety
switch and Fire Safe features. Meets CSA Class I, Division 2, Group A, B, C & D (Canada & US)
requirements. For oil supply with up to 15ft. of static head. Mounted in place of standard crankcase
inspection door ............................................................................................................................................
5229F X Lubricating System – Electric prelube pump for prelube and post lube for automatic or remote start
applications that have time to prelube prior to starting engine. Does not include relief valve which is
required for continuous operation. Includes dual voltage single phase motor driven pre-lube pump and
motor starter. Pre-lube motor voltage: 110/220 V AC 50 Hz, or 115/208-230V AC 60Hz. Omits
standard air/gas prelube motor drive system. Requires jacket water and lube oil to be heated to 65°F
(18°C) before starting. ..................................................................................................................................................
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. June 2022
PAGE ENG VHP-33
Code
P9394GSI S5
CONTROLS
6012C X BICERA Valve – Crankcase explosion relief. Quantity 6..............................................................................
6190G X Magnetic Pickup - Mounted. Meets Canadian Standards Association Class 1, Division 2, Group A, B, C,
& D hazardous location requirements. .......................................................................................................
6680 X 15" ESM2 HMI Display Panel -- Replaces standard 12" inch ESM2 HMI Display Panel ............................
6680A X 19" ESM2 HMI Display Panel -- Replaces standard 12" inch ESM2 HMI Display Panel ............................
6690A X 25' (7.6m) ESM2 Customer Interface Harness for customer connections, local control
and HMI on ESM2-equipped engines. Replaces 50’ (15.2 m) ESM2 Customer Interface Harness. .....
6690B X 100’ (30.4m) ESM2 Customer Interface Harness for customer connections, local control
and HMI on ESM2-equipped engines. Replaces 50’ (15.2 m) ESM2 Customer Interface Harness ......
6690C X 200’ (60.8m) ESM2 Customer Interface Harness for customer connections, local control
and HMI on ESM2-equipped engines. Replaces 50’ (15.2 m) ESM2 Customer Interface Harness. ......
MISCELLANEOUS
9974Q X Engine/Enginator that is Customs Union Compliant (Russia, Belarus, and Kazakhstan). Includes
SERIAL NUMBER SPECIFIC Technical Passport & Safety Justification in Russian and English,
Engine Operator's Manuals (one in Russian and one in English), and EAC label on unit. Enginators
include supplied equipment manuals that are in English only. May require additional lead time, consult
factory for delivery information ...................................................................................................................
9974U X Engine that is CE Mark Compliant. Includes a SERIAL NUMBER SPECIFIC Declaration of Incorporation
and Operator's Manual both in English. It is the responsibility of the entity (Packager, Distributor)
placing the complete package on the European market to ensure that the final complete package
(machine) is properly CE Marked and that the final customer is provided with the required translated
manuals. Waukesha can assist with translations at additional cost, contact Applications/Sales ..........
9974X X Required Label for Hazardous Location CSA Certification in US & Canada End Use. Adds a safety label
containing English and French language that is required to comply with the certification terms of the
equipment. Note: For end uses classified as Hazardous Locations Division 2 and in US & Canada.
Contact Application Engineering for use in other countries. .....................................................................
9998A X Shipping Skid – For overseas container .......................................................................................................
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. June 2022
PAGE ENG VHP-34
Code
P9394GSI S5
EXTENDED WARRANTY
10002AA X 16-Cylinder VHP Engine Extended Warranty -- 1 Year. Extended warranty excludes wear items and
includes only warrantable items as defined in Express Limited Warranty (ELW). Must be purchased at
time of original order. If applicable, the proper deferral process and preservation as outlined in Service
Bulletin 16-1855H (or most current) and WEDA 542 (or most current) must be followed or warranty
extension is void. Emission warranties for Waukesha’s emPact Emission Control System are NOT
EXTENDED by Extended Engine Warranties............................................................................................
10002BB X 16-Cylinder VHP Engine Extended Warranty -- 2 Years. Extended warranty excludes wear items and
includes only warrantable items as defined in Express Limited Warranty (ELW). Must be purchased at
time of original order. If applicable, the proper deferral process and preservation as outlined in Service
Bulletin 16-1855H (or most current) and WEDA 542 (or most current) must be followed or warranty
extension is void. Emission warranties for Waukesha’s emPact Emission Control System are NOT
EXTENDED by Extended Engine Warranties............................................................................................
10002CC X 16-Cylinder VHP Engine Extended Warranty -- 3 Years. Extended warranty excludes wear items and
includes only warrantable items as defined in Express Limited Warranty (ELW). Must be purchased at
time of original order. If applicable, the proper deferral process and preservation as outlined in Service
Bulletin 16-1855H (or most current) and WEDA 542 (or most current) must be followed or warranty
extension is void. Emission warranties for Waukesha’s emPact Emission Control System are NOT
EXTENDED by Extended Engine Warranties............................................................................................
DISCLAIMER
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. June 2022
PAGE ENG VGF-1
VGF Engines
MODEL ENGINE CODE LIST PRICE (July 2022)
F18G P2520G11
F18GL HCR P2520J11
F18GL LCR P2520J12
F18GLD P2520D11
F18SE P2520S12
H24GL HCR P2540J21
H24GL LCR P2540J22
H24GLD P2540D21
H24SE P2540S22
L36GL HCR P2560J11
L36GL LCR P2560J12
L36GLD P2560D11
L36GSI P2560S10
L36GSID P2560S11
P48GL HCR P2580J11
P48GL LCR P2580J12
P48GLD P2580D11
P48GSI P2580S10
P48GSID P2580S11
P48SE P6580S12
P48SE EPA P6580S13
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. July 2022
PAGE ENG VGF-2
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. July 2022
PAGE ENG VGF-3
GLD
GL
FUEL SYSTEM
2026 X X Gas Regulator – Fisher CS800, for G/GLD/GSID natural gas. Gas inlet pressure: 5 – 10 psig, shipped
loose. (Not for use with 9636A and 9638). ..........................................................................................
2027 X Gas Regulator – Fisher Y692, for natural gas only. Gas inlet pressure: 25 – 50 psig, mounted...............
2078 X Solenoid Valve – 2˝, 24V DC, normally closed, shipped loose. For use with fuels that do not contain
sulfur compounds. Maximum inlet pressure: 50 psi .............................................................................
IGNITION
3314A X X X Waukesha Custom Engine Control Electronic Ignition System – Components meet CSA Class I,
Division 2, Group A, B, C & D (Canada & US) hazardous location requirements. .............................
ELECTRICAL
3433F X X X Alternator – Denso, 24V DC, 50 amp, brushless, belt driven. Crankshaft pulley Code 8107 and drive
belts are included. Alternator system meets CSA Class I, Division 2, Group A, B, C & D (Canada &
US) hazardous location requirements. Cannot be used with Code 4290 .............................................
COOLING
4281A X X X Jacket Water Preheater – Thermostatically controlled, (100° F on; 120° F off), 120V AC, single
phase, 2500 watts .................................................................................................................................
4287 X X 210° F (99° C) Temperature Thermostats: Omits standard thermostats and adds high temperature
thermostats. Required for Digester/Landfill fuel systems ....................................................................
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. July 2022
PAGE ENG VGF-9
GLD
GL
Code MODEL F18G, GL, GLD ACCESSORIES
G
LUBRICATION
Kenco Oil Level Regulator for standard pan. Meets Canadian Standards Association Class 1, Division
5022 X X X 2, Group B, C & D hazardous location requirements...........................................................................
5112 X X Waukesha MICROSPIN Oil Filtration System – Includes three cleanable full flow filter elements,
MICROSPIN centrifugal bypass oil filter, shutoff valve, and oil return line. All components shipped
loose for customer mounting. Oil inlet and return lines are customer supplied. Reference Service
Bulletin 12–2698D or S7382-28 for installation information ................................................................
CONTROLS
6181B X X X Woodward EG-3P– Electrohydraulic governor actuator and oil supply system for quick start applications.
Requires appropriate control, ref: Codes 6184D. Includes magnetic pickup unit, Code 6190......................
6182 X X Woodward EG-3P -C – Electrohydraulic governor actuator and oil supply system for quick start applications.
Includes internal compensation functionality for additional stability control and response adjustment.
Requires appropriate control, ref: Codes 6184D. Includes magnetic pickup unit, Code 6190 ..........................
6184D X X Governor Control – Woodward 2301E, 24V DC, load sharing digital speed control for isochronous
operation of multiple units or a single unit stand alone or in parallel with utility. For use with Code
6181B. Meets Canadian Standards Association non-hazardous (ordinary) location requirements.
Shipped loose ........................................................................................................................................
6190 X X X Magnetic Pickup Unit – Mounted. Included in Code 6181B, 6182 .........................................................
6254A X X X Speed Control–Air Actuator – Westinghouse A2H (3 – 15 psi) for use with SG, PSG governors .......
INSTRUMENTS
Instrument Panel – Engine mounted. Includes oil pressure switchgauge, oil temperature
6410B X X X switchgauge, jacket water temperature switchgauge, intake manifold temperature switchgauge
and intake manifold pressure gauge ....................................................................................................
NOTE: All switchgauges and gauges are NOT wired by Waukesha.
6531A X X Exhaust Thermocouples – 6 individual cylinder, K–type thermocouples, plus pre and post turbine
thermocouples (8 total). Wired and terminated at engine mounted junction box ...............................
6538 X X Hourmeter/Tachometer Combination – Digital electronic, includes magnetic pick–up unit. Panel
mounted. Requires Code 6410B ..........................................................................................................
POWER TAKE–OFF
8000 X X X Stub Shaft – 3.94˝ (100 mm) diameter x 8.50˝ (216 mm) long. 1.00˝ (25 mm) x 1.00˝ (25 mm) x 6˝ (150
mm) keyway with key, for attachment to standard flywheel. Not for side load applications. Customer
to supply guarding ...................................................................................................................................
8101 X X X Front Mounted Shaft – 2.2520/2.2479˝ O.D. and 4.75˝ long. For QD bushing customer supplied
crankshaft pulleys. Mounted. Reference SA4052–13 for side load and drive data. See SC7764–28
for installation. Customer to supply guarding. Not compatible with code 4290 or 8106. ....................
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. July 2022
PAGE ENG VGF-10
GLD
GL
Code MODEL F18G, GL, GLD ACCESSORIES
G
8106 X X X Crankshaft Pulley – Four 5V section grooves, 8.76˝ pitch diameter, symmetrically spaced. Mounted
on front of crankshaft, includes guard and spacer for fan/cooler drives. Not compatible with codes
4290, 8101, or 8102. .............................................................................................................................
MISCELLANEOUS
9974Q X X X Engine/Enginator that is Customs Union Compliant (Russia, Belarus, and Kazakhstan). Includes
SERIAL NUMBER SPECIFIC Technical Passport & Safety Justification in Russian and English,
Engine Operator's Manuals (one in Russian and one in English), and EAC label on unit. Enginators
include supplied equipment manuals that are in English only. May require additional lead time,
consult factory for delivery information .................................................................................................
9974U X X X Engine that is CE Mark Compliant. Includes a SERIAL NUMBER SPECIFIC Declaration of
Incorporation and Operator's Manual both in English. It is the responsibility of the entity (Packager,
Distributor) placing the complete package on the European market to ensure that the final complete
package (machine) is properly CE Marked and that the final customer is provided with the required
translated manuals. Waukesha can assist with translations at additional cost, contact
Applications/Sales .................................................................................................................................
9974W X X X Required label for Hazardous Location CSA Certification in US & Canada end use. Adds a safety
label containing English and French language that is required to comply with the certification terms
of the equipment. For use with code 3314A. Note: For end uses classified as Hazardous Locations
Division 2 and in US & Canada. Contact Application Engineering for use in other countries. ...........
EXTENDED WARRANTY
10003AA X X X 6-Cylinder VGF Engine Extended Warranty -- 1 Year. Extended warranty excludes wear items and
includes only warrantable items as defined in Express Limited Warranty (ELW). Must be purchased
at time of original order. If applicable, the proper deferral process and preservation as outlined in
Service Bulletin 16-1855H (or most current) and WEDA 542 (or most current) must be followed or
warranty extension is void.....................................................................................................................
10003BB X X X 6-Cylinder VGF Engine Extended Warranty -- 2 Years. Extended warranty excludes wear items and
includes only warrantable items as defined in Express Limited Warranty (ELW). Must be purchased
at time of original order. If applicable, the proper deferral process and preservation as outlined in
Service Bulletin 16-1855H (or most current) and WEDA 542 (or most current) must be followed or
warranty extension is void.....................................................................................................................
10003CC X X X 6-Cylinder VGF Engine Extended Warranty -- 3 Years. Extended warranty excludes wear items and
includes only warrantable items as defined in Express Limited Warranty (ELW). Must be purchased
at time of original order. If applicable, the proper deferral process and preservation as outlined in
Service Bulletin 16-1855H (or most current) and WEDA 542 (or most current) must be followed or
warranty extension is void.....................................................................................................................
DISCLAIMER
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. July 2022
PAGE ENG VGF-11
FUEL SYSTEM
2022 Gas Regulator: 2” NPT Knockdown regulator for Low Pressure fuel (outlet 3-10 psi / inlet 20-200 psi).
Shipped Loose.....................................................................................................................................................................
2034D Dual Fuel System: Natural gas/field gas and LP(HD-5). Allows the engine to automatically or manually switch from
natural/field gas to liquid propane (LP) without shutting down. Engine mounted vaporizers, MAS (valve), pressure
relief valve, fuel pressure sensor, and switching solenoids. Switching controls included. LP fuel pressure 30-
300PSIG.See S-07546-40 for further fuel specifications. System engine mounted. .......................................................
2048A Low Btu Fuel System -- Fuel system (Carburetor) for fuels with heating values from 650-850 Btu/ft3 LHV. .....................
2320D Precleaner, Heavy Duty inertial separator, for standard air cleaner. Removes std. Air cleaner Rain Shield ....................
NOTE: Precleaners are recommended for applications in dusty environments or when dust conditions are
unpredictable.
ELECTRICAL
3433G Alternator – Denso, 24V DC, 50 amp, brushless, belt driven. Crankshaft pulley Code 8107 and drive belts are included.
Alternator system meets CSA Class I, Division 2, Group A, B, C & D (Canada & US) hazardous location requirements.
Cannot be used with Code 4290B .....................................................................................................................................
COOLING
4281D Jacket Water Preheater – Thermostatically controlled, (100° F on; 120° F off), 240V AC, single phase, 6000 watts.
Customer supplied logic & shipped loose. (Min/Max ambient temperature 40F – 1040F)...............................................
LUBRICATION
5022C Kenco Oil Level Regulator for standard pan. Meets Canadian Standards Association Class 1, Division 2, Group B, C &
D hazardous location requirements. ..................................................................................................................................
5205D Prelube Pump – Electric prelube pump for prelube and post lube. Engine mounted. Includes 24V DC motor driven pre-
lube pump. Continuous prelube not available ..................................................................................................................
5205E Prelube Pump - Air Driven prelube pump for prelube and post lube. Engine mounted, air/gas motor-driven. ................
5205F Prelube Pump – Electric prelube pump for prelube and post lube. Pump Motor engine mounted, Control Box shipped
loose. Designed for indoor duty. Continuous prelube not available. Pump motor: 208-240V AC, single phase, 50/60
Hz. .......................................................................................................................................................................................
INSTRUMENTS
6190 Magnetic Pickup Unit – Mounted. ..........................................................................................................................................
6531D Exhaust Thermocouples – 6 individual cylinder, K–type thermocouples, includes post turbine TC and values displayed
in HMI via MODBUS ...........................................................................................................................................................
6650D ESM customer interface & option harnesses 50ft. Replaces standard 25 ft. harness ........................................................
6650GG ESM customer interface & option harnesses 100ft Replaces standard 25 ft. harness. ......................................................
POWER TAKE–OFF
8000 Stub Shaft – 3.94˝ (100 mm) diameter x 8.50˝ (216 mm) long. 1.00˝ (25 mm) x 1.00˝ (25 mm) x 6˝ (150 mm) keyway with
key, for attachment to standard flywheel. Not for side load applications. Customer to supply guarding .......
8101A Front Mounted Shaft – 2.2520/2.2479˝ O.D. and 4.75˝ long. For QD bushing customer supplied crankshaft pulleys.
Mounted. Reference SA4052–13 for side load and drive data. Customer to supply guarding. .......................................
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. July 2022
PAGE ENG VGF-12
MISCELLANEOUS
7006A Exhaust Silencer – Residential Rating, Size 8” flanged, end inlet, end outlet. Shipped loose
…………………………………………………………
7117 Exhaust Flex – 8” Flange, Max design press. @ 15000F, 88psi .........................................................................................
9974Q Engine/Enginator that is Customs Union Compliant (Russia, Belarus, and Kazakhstan). Includes SERIAL NUMBER
SPECIFIC Technical Passport & Safety Justification in Russian and English, Engine Operator's Manuals (one in
Russian and one in English), and EAC label on unit. Enginators include supplied equipment manuals that are in
English only. May require additional lead time, consult factory for delivery information. ................................................
9974U Engine that is CE Mark Compliant. Includes a SERIAL NUMBER SPECIFIC Declaration of Incorporation and Operator's
Manual both in English. It is the responsibility of the entity (Packager, Distributor..) placing the complete package on
the European market to ensure that the final complete package (machine) is properly CE Marked and that the final
customer is
provided with the required translated manuals. Waukesha can assist with translations at additional cost, contact
Applications/Sales ..............................................................................................................................................................
9974X Required label for Hazardous Location CSA Certification in US & Canada end use. Adds a safety label containing English
and French language that is required to comply with the certification terms of the equipment. Note: For end uses
classified as Hazardous Locations Division 2 and in US & Canada. Contact Application Engineering for use in other
countries.......................................................................................................................................................
EXTENDED WARRANTY
10003AA 6-Cylinder VGF Engine Extended Warranty -- 1 Year. Extended warranty excludes wear items and includes only
warrantable items as defined in Express Limited Warranty (ELW). Must be purchased at time of original order. If
applicable, the proper deferral process and preservation as outlined in Service Bulletin 16-1855H (or most current)
and WEDA 542 (or most current) must be followed or warranty extension is void.
10003BB 6-Cylinder VGF Engine Extended Warranty -- 2 Years. Extended warranty excludes wear items and includes only
warrantable items as defined in Express Limited Warranty (ELW). Must be purchased at time of original order. If
applicable, the proper deferral process and preservation as outlined in Service Bulletin 16-1855H (or most current)
and WEDA 542 (or most current) must be followed or warranty extension is void.
10003CC 6-Cylinder VGF Engine Extended Warranty -- 3 Years. Extended warranty excludes wear items and includes only
warrantable items as defined in Express Limited Warranty (ELW). Must be purchased at time of original order. If
applicable, the proper deferral process and preservation as outlined in Service Bulletin 16-1855H (or most current)
and WEDA 542 (or most current) must be followed or warranty extension is void.
DISCLAIMER
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. July 2022
PAGE ENG VGF-13
STANDARD EQUIPMENT
AIR CLEANER – Two stage, dry panel type with rain shield and FLYWHEEL HOUSING – SAE #0, nodular iron housing. Provision for
service indicator. Engine mounted. two magnetic pickups and vertical mounting pads.
BARRING DEVICE – Manual. GOVERNOR – Woodward SG hydraulic with manual speed control.
BREATHER – Crankcase, closed type (mounted). IGNITION – Waukesha Custom Engine Control electronic ignition
CARBURETOR – Single natural gas Impco 400 updraft. system with coils, cables and spark plugs. Non–shielded. 24V DC
CONNECTING RODS – Drop forged alloy steel, angle split, serrated power required. Includes emergency stop/service engine protection
joint, oil jet piston pin lubrication. switch for local override of remote controls.
COOLING SYSTEM – Jacket water: gear driven jacket water pump, INTERCOOLER – Air–to–water.
thermostatically controlled, full flow bypass type with nominal 180° LIFTING EYES – For engine only.
F (82° C) outlet temperature. Auxiliary water: thermostatically LUBRICATION SYSTEM – Gear type pump, full flow spin–on filters
controlled, gear driven pump supplies water to intercooler and oil and industrial base type oil pan, 56 gallon (212 Liters) capacity,
cooler circuit. including filters. Engine mounted plate type oil cooler.
CRANKCASE – Alloy cast iron, fully ribbed, integral with cylinder MOUNTING – Base type oil pan.
frame. PAINT – Oilfield orange.
CRANKSHAFT – Drop forged alloy steel, dynamically balanced and PISTONS – Aluminum alloy, three ring, with patented high turbulence
fully counterweighted. Viscous vibration dampener. combustion bowl. Oil jet cooled with full floating piston pin. Low
CYLINDERS – Removable wet type liners of centrifugally cast alloy Compression Ratio (LCR) 8.7:1 for tolerance of low and varying
iron. fuel WKI.
CYLINDER HEADS – Eight interchangeable, valve–in–head type, TURBOCHARGER – Exhaust driven, dry type with wastegate. For
with two hard faced intake and two hard faced exhaust valves per 1400 – 1800 rpm applications.
cylinder. Replaceable intake and exhaust valve seats. Mechanical It is the customer’s responsibility to
valve lifters with pivoted roller followers. provide the necessary equipment
ENGINE ROTATION – Counterclockwise when facing flywheel. to protect the engine from low oil
EXHAUST SYSTEM – Water cooled exhaust manifold. Outlet flange pressure, high water temperature, high intake manifold temperature
for ANSI 8” 125# flange. and overspeed conditions. Also a fuel shutoff valve must be provided
FLYWHEEL – With 150 tooth ring gear (for Delco electric and air/gas to positively stop gas flow to the engine for both normal and
starters). Flywheel machined to accept SAE 620D, 18” (457 mm) emergency shutdown.
diameter clutch.
GLD
GL
FUEL SYSTEM
2024 X Gas Regulator – Maxitrol RV91, for GLD/GSID natural gas. Gas inlet pressure: 8” – 20” W.C., shipped
loose. Do not use with Code 9636A or 9638 ........................................................................................
2025 X Gas Regulator – Fisher 66, for GLD/GSID natural gas. Gas inlet pressure: 20” W.C. – 10 psig, shipped
loose .......................................................................................................................................................
2026 X Gas Regulator – Fisher CS800, for G/GLD/GSID natural gas. Gas inlet pressure: 5 – 10 psig, Shipped
loose. (Not for use with 9636A or 9638) ...............................................................................................
2027 X Gas Regulator – Fisher Y692, for natural gas only. Gas inlet pressure: 25 – 50 psig, mounted ...............
2034A Dual Fuel System – Natural gas and propane vapor. Customer must provide valves for automatic or
manual fuel changeover. Equipment includes two gas regulators. Fisher 66 for natural gas. Gas inlet
pressure: 18” wc to 10 psi. Shipped loose. Fisher Y610A for propane gas. Gas inlet pressure: 5 to 10
psi (shipped loose) lambda adjust valve. Shipped loose. Propane vaporizer not included. See S7522 –
10 in the Technical Data Manual for ratings. (Retard ignition timing when changing to propane fuel.) ..
NOTE: 10% overload is not available for propane.
2078 X Solenoid Valve – 2˝, 24V DC, normally closed, shipped loose. For use with fuels that do not contain
sulfur compounds. Maximum inlet pressure: 50 psi .............................................................................
IGNITION
3314A X X Waukesha Custom Engine Control Electronic Ignition System – Components meet CSA Class I, Division
2, Group A, B, C & D (Canada & US) hazardous location requirements ..............................................
ELECTRICAL
3433F X X Alternator – Denso, 24V DC, 50 amp, brushless, belt driven. Crankshaft pulley Code 8107 and drive
belts are included. Alternator system meets CSA Class I, Division 2, Group A, B, C & D (Canada &
US) hazardous location requirements. Cannot be used with Code 4290............................................
COOLING
4281A X X Jacket Water Preheater – Thermostatically controlled, (100° F on; 120° F off), 120V AC, single phase,
2500 watts ..............................................................................................................................................
Customer must provide engine protection shutdown
equipment for high temperature, low water level, and loss of
water circulation.
4287 X X 210° F (99° C) Temperature Thermostats: Omits standard thermostats and adds high temperature
thermostats for operation up to 210° F (99° C). Required for Digester/Landfill fuel systems .............
LUBRICATION
5022 X X Kenco Oil Level Regulator for standard pan. Meets Canadian Standards Association Class 1, Division
2, Group B, C & D hazardous location requirements. ..........................................................................
5112 X X Waukesha MICROSPIN Oil Filtration System – Includes three cleanable full flow filter elements,
MICROSPIN centrifugal bypass oil filter, shutoff valve, and oil return line. All components shipped
loose for customer mounting. Oil inlet and return lines are customer supplied per specific
application. Reference Service Bulletin 12–2698D or S7382-28 for installation information .............
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. July 2022
PAGE ENG VGF-18
GLD
GL
Code MODEL H24GL, GLD ACCESSORIES
CONTROLS
6181B X X Woodward EG-3P – Electrohydraulic governor actuator and oil supply system for quick start
applications. Requires appropriate control, ref: Codes 6184D. Includes magnetic pickup unit, Code
6190 .......................................................................................................................................................
6182 X X Woodward EG-3P-C – Electrohydraulic governor actuator and oil supply system for quick start
applications. Includes internal compensation functionality for additional stability control and response
adjustment. Requires appropriate control, ref: Codes 6184D. Includes magnetic pickup unit, Code
6190 .......................................................................................................................................................
6184D X X Governor Control – Woodward 2301E, 24V DC, load sharing digital speed control for isochronous
operation of multiple units or a single unit stand alone or in parallel with utility. For use with Code
6181B. Meets Canadian Standards Association non-hazardous (ordinary) location requirements.
Shipped loose ........................................................................................................................................
6190 X X Magnetic Pickup Unit – Mounted. Included in Code 6181B, 6182 ..........................................................
6254A X X Speed Control–Air Actuator – Westinghouse A2H (3 – 15 psi) for use with SG, PSG governors .........
INSTRUMENTS
6410B X X Instrument Panel – Engine mounted. Includes oil pressure switchgauge, oil temperature switchgauge,
jacket water temperature switchgauge, intake manifold temperature switchgauge and intake
manifold pressure gauge.
NOTE: All switchgauges and gauges are NOT wired by Waukesha.
6531 X X Exhaust Thermocouples – 8 individual cylinder, K–type thermocouples, plus pre and post turbine
thermocouples (10 total). Wired and terminated at engine mounted junction box ..............................
6538 X X Hourmeter/Tachometer Combination – Digital electronic, includes magnetic pick–up unit. Panel
mounted. Requires Code 6410B ...........................................................................................................
MISCELLANEOUS
9974Q X X Engine/Enginator that is Customs Union Compliant (Russia, Belarus, and Kazakhstan). Includes
SERIAL NUMBER SPECIFIC Technical Passport & Safety Justification in Russian and English,
Engine Operator's Manuals (one in Russian and one in English), and EAC label on unit.
Enginators include supplied equipment manuals that are in English only. May require additional
lead time, consult factory for delivery information. ..............................................................................
9974U X X Engine that is CE Mark Compliant. Includes a SERIAL NUMBER SPECIFIC Declaration of
Incorporation and Operator's Manual both in English. It is the responsibility of the entity (Packager,
Distributor) placing the complete package on the European market to ensure that the final complete
package (machine) is properly CE Marked and that the final customer is provided with the required
translated manuals. Waukesha can assist with translations at additional cost, contact
Applications/Sales .................................................................................................................................
9974 X X Required label for Hazardous Location CSA Certification in US & Canada end use. Adds a safety label
W containing English and French language that is required to comply with the certification terms of the
equipment. For use with code 3314A. Note: For end uses classified as Hazardous Locations
Division 2 and in US & Canada. Contact Application Engineering for use in other countries.................
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. July 2022
PAGE ENG VGF-19
GLD
GL
Code MODEL H24GL, GLD ACCESSORIES
EXTENDED WARRANTY
10004 X X 8-Cylinder VGF Engine Extended Warranty -- 1 Year. Extended warranty excludes wear items and
AA includes only warrantable items as defined in Express Limited Warranty (ELW). Must be purchased
at time of original order. If applicable, the proper deferral process and preservation as outlined in
Service Bulletin 16-1855H (or most current) and WEDA 542 (or most current) must be followed or
warranty extension is void. ....................................................................................................................
10004 X X 8-Cylinder VGF Engine Extended Warranty -- 2 Years. Extended warranty excludes wear items and
BB includes only warrantable items as defined in Express Limited Warranty (ELW). Must be purchased
at time of original order. If applicable, the proper deferral process and preservation as outlined in
Service Bulletin 16-1855H (or most current) and WEDA 542 (or most current) must be followed or
warranty extension is void. ....................................................................................................................
10004 X X 8-Cylinder VGF Engine Extended Warranty -- 3 Years. Extended warranty excludes wear items and
CC includes only warrantable items as defined in Express Limited Warranty (ELW). Must be purchased
at time of original order. If applicable, the proper deferral process and preservation as outlined in
Service Bulletin 16-1855H (or most current) and WEDA 542 (or most current) must be followed or
warranty extension is void. ....................................................................................................................
DISCLAIMER
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. July 2022
PAGE ENG VGF-20
FUEL SYSTEM
2022 Gas Regulator: 2” NPT Knockdown regulator for Low Pressure fuel (outlet 3-10 psi / inlet 20-200 psi). Shipped Loose....
2034D Dual Fuel System: Natural gas/field gas and LP(HD-5). Allows the engine to automatically or manually switch from
natural/field gas to liquid propane (LP) without shutting down. Engine mounted vaporizers, MAS (valve), pressure
relief valve, fuel pressure sensor, and switching solenoids. Switching controls included. LP fuel pressure 30-
300PSIG.See S-07546-40 for further fuel specifications. System engine mounted. .......................................................
2048A Low Btu Fuel System -- Fuel system (Carburetor) for fuels with heating values from 650-850 Btu/ft3 LHV .................
2320D Precleaner, Heavy Duty intertial separator. ..........................................................................................................................
NOTE: Precleaners are recommended for applications in dusty environments or when dust conditions are
unpredictable.
ELECTRICAL
3433G Alternator – Denso, 24V DC, 50 amp, brushless, belt driven. Crankshaft pulley Code 8107 and drive belts are included.
Alternator system meets CSA Class I, Division 2, Group A, B, C & D (Canada & US) hazardous location requirements.
Cannot be used with Code 4290B .....................................................................................................................................
COOLING
4281D Jacket Water Preheater – Thermostatically controlled, (100° F on; 120° F off), 240V AC, single phase, 6000 watts.
Customer supplied logic & shipped loose. (Min/Max ambient temperature 40F – 1040F) ..................................................
LUBRICATION
5022C Kenco Oil Level Regulator for standard pan. Meets Canadian Standards Association Class 1, Division 2, Group B, C &
D hazardous location requirements. ..................................................................................................................................
5205D Prelube Pump – Electric prelube pump for prelube and post lube. Engine mounted. Includes 24V DC motor driven pre-
lube pump. Continuous prelube not available .................................................................................................................
5205E Prelube Pump - Air Driven prelube pump for prelube and post lube. Engine mounted, air/gas motor-driven. ................
5205F Prelube Pump – Electric prelube pump for prelube and post lube. Pump Motor engine mounted, Control Box shipped
loose. Designed for indoor duty. Continuous prelube not available. Pump motor: 208-240V AC, single phase, 50/60
Hz. .......................................................................................................................................................................................
INSTRUMENTS
6190 Magnetic Pickup Unit – Mounted ............................................................................................................................................
6531E Exhaust Thermocouples – 8 individual cylinder, K–type thermocouples, plus post turbine TC and values displayed in
HMI via MODBUS ...............................................................................................................................................................
6650D ESM customer interface & option harnesses 50ft. Replaces standard 25 ft. harness. .......................................................
6650GG ESM customer interface & option harnesses 100ft. Replaces standard 25 ft. harness. .....................................................
POWER TAKE–OFF
8000 Stub Shaft – 3.94˝ (100 mm) diameter x 8.50˝ (216 mm) long. 1.00˝ (25 mm) x 1.00˝ (25 mm) x 6˝ (150 mm) keyway with
key, for attachment to standard flywheel. Not for side load applications. Customer to supply guarding ..........................
8101A Front Mounted Shaft – 2.2520/2.2479˝ O.D. and 4.75˝ long. For QD bushing customer supplied crankshaft pulleys.
Mounted. Reference SA4052–13 for side load and drive data. Customer to supply guarding. .......................................
8106A Crankshaft Pulley – Four 5V section grooves, 8.76˝ pitch diameter, symmetrically spaced. Mounted on front of
crankshaft, includes guard and spacer for fan/cooler drives.............................................................................................
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. July 2022
PAGE ENG VGF-21
MISCELLANEOUS
7007 Exhaust Silencer – Residential Rating, Size 8” flanged, end inlet, end outlet. Shipped loose ..........................................
9974Q Engine/Enginator that is Customs Union Compliant (Russia, Belarus, and Kazakhstan). Includes SERIAL NUMBER
SPECIFIC Technical Passport & Safety Justification in Russian and English, Engine Operator's Manuals (one in
Russian and one in English), and EAC label on unit. Enginators include supplied equipment manuals that are in
English only. May require additional lead time, consult factory for delivery information .................................................
9974U Engine that is CE Mark Compliant. Includes a SERIAL NUMBER SPECIFIC Declaration of Incorporation and Operator's
Manual both in English. It is the responsibility of the entity (Packager, Distributor..) placing the complete package on
the European market to ensure that the final complete package (machine) is properly CE Marked and that the final
customer is provided with the required translated manuals. Waukesha can assist with translations at additional cost,
contact Applications/Sales. ................................................................................................................................................
9974X Required label for Hazardous Location CSA Certification in US & Canada end use. Adds a safety label containing English
and French language that is required to comply with the certification terms of the equipment. Note: For end uses
classified as Hazardous Locations Division 2 and in US & Canada. Contact Application Engineering for use in other
countries. ............................................................................................................................................................................
EXTENDED WARRANTY
10004AA 8-Cylinder VGF Engine Extended Warranty -- 1 Year. Extended warranty excludes wear items and includes only
warrantable items as defined in Express Limited Warranty (ELW). Must be purchased at time of original order. If
applicable, the proper deferral process and preservation as outlined in Service Bulletin 16-1855H (or most current)
and WEDA 542 (or most current) must be followed or warranty extension is void. ........................................................
10004BB 8-Cylinder VGF Engine Extended Warranty -- 2 Years. Extended warranty excludes wear items and includes only
warrantable items as defined in Express Limited Warranty (ELW). Must be purchased at time of original order. If
applicable, the proper deferral process and preservation as outlined in Service Bulletin 16-1855H (or most current)
and WEDA 542 (or most current) must be followed or warranty extension is void. ........................................................
10004CC 8-Cylinder VGF Engine Extended Warranty -- 3 Years. Extended warranty excludes wear items and includes only
warrantable items as defined in Express Limited Warranty (ELW). Must be purchased at time of original order. If
applicable, the proper deferral process and preservation as outlined in Service Bulletin 16-1855H (or most current)
and WEDA 542 (or most current) must be followed or warranty extension is void. ........................................................
DISCLAIMER
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. July 2022
PAGE ENG VGF-22
L36GSID TURBOCHARGED AND INTERCOOLED GAS ENGINE FOR LOW FUEL PRESSURE
5.98 Inch (152 mm) Bore x 6.50 Inch (165 mm) Stroke – 12 Cylinders
2,193 Cubic Inch (36 Liter) Displacement
STANDARD EQUIPMENT
AIR CLEANER – Dual two stage, dry panel type with rain shield and FLYWHEEL HOUSING – SAE #00, nodular iron housing. Provision
service indicator. Engine mounted. for two magnetic pickups.
BARRING DEVICE – Manual. GOVERNOR – Woodward PSG hydraulic.
BREATHER – Crankcase, closed type (mounted). IGNITION – Waukesha Custom Engine Control electronic ignition
CARBURETOR – Two natural gas Deltec carburetors. Mounted system with coils, cables and spark plugs. Non–shielded. 24V DC
before turbochargers for low fuel pressure. Includes speed switch power required. Includes emergency stop/service engine protection
and solenoid that opens upon cranking and closes when engine switch for local override of remote controls.
rotation ceases. INTERCOOLER – Two pass, fin and tube, air–to–water.
CONTROLS – Local shutdown switch, engine mounted. LIFTING EYES – For engine only.
CONNECTING RODS – Drop forged alloy steel, angle split, serrated LUBRICATION SYSTEM – Gear type pump, replaceable spin on oil
joint, oil jet piston pin lubrication. filters and industrial base type oil pan, 86 gallon (326 Liters)
COOLING SYSTEM – Jacket water: gear driven jacket water pump, capacity. Engine mounted shell and tube oil cooler, thermostatic
thermostatically controlled, full flow bypass type with nominal 180° F valve for oil temperature control, and prelube pump. Customer
(82° C) outlet temperature. 4˝ ANSI flange connection. Auxiliary water: supplied prelube pump motor frame size must conform to frame size
thermostatically controlled, gear driven pump supplies water to 56C and “M” drive configuration.
intercooler and oil cooler circuit. 2˝ special companion flanges MOUNTING – Base type oil pan.
supplied. PAINT – Oilfield orange.
CRANKCASE – Alloy cast iron, fully ribbed, integral with cylinder PISTONS – Aluminum alloy, three ring, with deep central combustion
frame. bowl. Oil jet cooled with full floating piston pin. 8.6:1 compression
CRANKSHAFT – Drop forged alloy steel, dynamically balanced and ratio.
fully counterweighted. Viscous vibration dampener. TURBOCHARGER – Two exhaust driven, dry type with wastegate.
CYLINDERS – Removable wet type liners of centrifugally cast alloy For 1400 – 1800 rpm applications.
iron. It is the customer’s responsibility
CYLINDER HEADS – Twelve interchangeable, valve–in–head type, to provide the necessary
with two hard faced intake and two hard faced exhaust valves per equipment to protect the engine
cylinder. Replaceable intake and exhaust valve seats. Mechanical from low oil pressure, high water temperature, and overspeed
valve lifters with pivoted roller followers. conditions. Deltec Fuel system requires a shutoff valve that opens
ENGINE ROTATION – Counterclockwise when facing flywheel. upon cranking and closes whenever engine rotation ceases. Failure to
EXHAUST SYSTEM – Water cooled exhaust manifolds. Single outlet provide the valve will cause an explosive environment resulting in
flange for ANSI 10” 125# flange. severe personal injury.
FLYWHEEL – With 165 tooth ring gear (for Delco electric and air/gas
starters). Flywheel machined to accept SAE 620D-21, 21” (533 mm)
diameter clutch, or SAE J927B–210 flywheel converter.
GSID
GLD
GSI
GL
FUEL SYSTEM
2024A X X One Gas Regulator – Fisher 66Z, (3˝ flange). Gas inlet pressure 8˝ W.C. – 2.5 psig.
Shipped loose
2025A X X One Gas Regulator – Fisher 66Z, (2˝ NPT). Gas inlet pressure 2.5 – 5 psig. Shipped
loose. (For gas pressure above 5 psi, a step down regulator is required.).....................
2027 X X Gas Regulator – Fisher Y692, for natural gas only. Gas inlet pressure 25 – 50 psig. Mounted
...........................................................................................................................................
2078 X X Solenoid Valve – 2˝, 24V DC, normally closed, shipped loose. For use with fuels that do
not contain sulfur compounds. Maximum pressure: 50 psi .............................................
IGNITION
3314A X X X X Waukesha Custom Engine Control Electronic Ignition System – Components meet CSA
Class I, Division 2, Group A, B, C & D (Canada & US) hazardous location requirements
...........................................................................................................................................
COOLING
4281C X X X X Jacket Water Preheater – Thermostatically controlled, (100° F on; 120° F off), 240V AC,
single phase, 9000 watt ....................................................................................................
4287 X X X X High Temperature Thermostats: Omits standard thermostats and adds high temperature
thermostats for operation up to 210° F (99° C). Recommended for Digester/Landfill fuel
systems .............................................................................................................................
LUBRICATION
5022 X X X X Kenco Oil Level Regulator for standard pan. Meets Canadian Standards Association
Class 1, Division 2, Group B, C, & D hazardous location requirements. ........................
5112A X X X X Waukesha MICROSPIN Oil Filtration System – Includes mounted MICROSPIN
centrifugal bypass oil filter with shutoff valve ...................................................................
5206 X X X X Prelube Pump Motor – Engine mounted, designed for indoor duty. Continuous prelube
not available. Pump motor: 230V AC, single phase, 50/60 Hz. Rated ¾ hp,
950-1200 rpm .....................................................................................................................
5208 X X X X Prelube Pump Motor – Engine mounted, designed for indoor duty. Continuous prelube
not available. Pump motor: 24V DC ...............................................................................
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. July 2022
PAGE ENG VGF-28
GSID
GLD
GSI
GL
Code MODEL L36 GL, GLD, GSI, GSID ACCESSORIES
CONTROLS
6012B X X X X Pressure relief oil pan doors (three doors). Note: Oil capacity is reduced to 43 gallons ...
6181B X X X X Woodward EG-3P – Electrohydraulic governor actuator. Requires appropriate control,
Ref: Codes 6184D. Includes magnetic pickup unit, Code 6190......................................
6184D X X X X Governor Control – Woodward 2301E, 24V DC, load sharing digital speed control for
isochronous operation of multiple units or a single unit stand alone or in parallel with
utility. For use with Code 6181B. Meets Canadian Standards non-hazardous (ordinary)
location requirements. Shipped loose ..............................................................................
6190 X X X X Magnetic Pickup Unit – Mounted, included in Code 6181B................................................
6254A X X X X Speed Control, Air Actuator – Westinghouse A2H (3 – 15 psi) for use
with PSG governor ............................................................................................................
INSTRUMENTS
6410B X X X X Instrument Panel – Engine mounted. Includes oil pressure switchgauge, oil
temperature switchgauge, jacket water temperature switchgauge, intake manifold
temperature switchgauge and intake manifold pressure gauge .....................................
NOTE: All switchgauges and gauges are NOT wired by Waukesha.
6531C X X X X Exhaust Thermocouples – 12 Individual cylinders, K–type thermocouples, plus two pre
turbine and one post turbine (15 total). Wired and terminated at engine mounted
junction box .......................................................................................................................
6538 X X X X Hourmeter/Tachometer Combination – Digital electronic, includes magnetic pickup unit.
Panel mounted. Requires Code 6410B ...........................................................................
MISCELLANEOUS
9974Q X X X X Engine/Enginator that is Customs Union Compliant (Russia, Belarus, and
Kazakhstan). Includes SERIAL NUMBER SPECIFIC Technical Passport & Safety
Justification in Russian and English, Engine Operator's Manuals (one in Russian and one
in English), and EAC label on unit. Enginators include supplied equipment manuals that
are in English only. May require additional lead time, consult factory for delivery
information. ........................................................................................................................
9974U X X X X Engine that is CE Mark Compliant. Includes a SERIAL NUMBER SPECIFIC Declaration of
Incorporation and Operator's Manual both in English. It is the responsibility of the entity
(Packager, Distributor) placing the complete package on the European market to ensure
that the final complete package (machine) is properly CE Marked and that the final
customer is provided with the required translated manuals. Waukesha can assist with
translations at additional cost, contact Applications/Sales .................................................
9974W X X X X Required label for Hazardous Location CSA Certification in US & Canada end use. Adds
a safety label containing English and French language that is required to comply with the
certification terms of the equipment. For use with code 3314A. Note: For end uses
classified as Hazardous Locations Division 2 and in US & Canada. Contact Application
Engineering for use in other countries. .............................................................................
9998 X X X X Shipping Skid - For Overseas Container...............................................................................
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. July 2022
PAGE ENG VGF-29
GSID
GLD
GSI
GL
Code MODEL L36 GL, GLD, GSI, GSID ACCESSORIES
EXTENDED WARRANTY
12-Cylinder VGF Engine Extended Warranty -- 1 Year. Extended warranty excludes wear
10005AA X X X X
items and includes only warrantable items as defined in Express Limited Warranty
(ELW). Must be purchased at time of original order. If applicable, the proper deferral
process and preservation as outlined in Service Bulletin 16-1855H (or most current)
and WEDA 542 (or most current) must be followed or warranty extension is void.. ......
12-Cylinder VGF Engine Extended Warranty -- 2 Years. Extended warranty excludes
10005BB X X X X
wear items and includes only warrantable items as defined in Express Limited
Warranty (ELW). Must be purchased at time of original order. If applicable, the proper
deferral process and preservation as outlined in Service Bulletin 16-1855H (or most
current) and WEDA 542 (or most current) must be followed or warranty extension is
void. ...................................................................................................................................
12-Cylinder VGF Engine Extended Warranty -- 3 Years. Extended warranty excludes
10005CC X X X X
wear items and includes only warrantable items as defined in Express Limited
Warranty (ELW). Must be purchased at time of original order. If applicable, the proper
deferral process and preservation as outlined in Service Bulletin 16-1855H (or most
current) and WEDA 542 (or most current) must be followed or warranty extension is
void. ...................................................................................................................................
DISCLAIMER
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. July 2022
PAGE ENG VGF-30
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. July 2022
PAGE ENG VGF-32
STANDARD EQUIPMENT
AIR CLEANER – Dual two stage, dry panel type with rain shield and flange for ANSI 10” 125# flange.
service indicator. Engine mounted. FLYWHEEL – With 165 tooth ring gear (for Delco electric and air/gas
BARRING DEVICE – Manual. starters). Flywheel machined to accept SAE 620D-21, 21” (533 mm)
BREATHER – Crankcase, closed type (mounted). diameter clutch, or SAE J927B–210 flywheel converter.
CARBURETOR – Two natural gas Impco 600 Varifuel downdraft. FLYWHEEL HOUSING – SAE #00, nodular iron housing. Provision
CONNECTING RODS – Drop forged alloy steel, angle split, serrated for two magnetic pickups.
joint, oil jet piston pin lubrication. GOVERNOR – Woodward PSG hydraulic.
COOLING SYSTEM – Jacket water: gear driven jacket water pump, IGNITION – Waukesha Custom Engine Control electronic ignition
thermostatically controlled, full flow bypass type with nominal 180° F system with coils, cables and spark plugs. Non–shielded. 24V DC
(82° C) outlet temperature. 4˝ ANSI flange connection. Auxiliary water: power required. Includes emergency stop/service engine protection
thermostatically controlled, gear driven pump supplies water to switch for local override of remote controls.
intercooler and oil cooler circuit. 2˝ special companion flanges INTERCOOLER – Two pass, fin and tube, air–to–water.
supplied. LIFTING EYES – For engine only.
CRANKCASE – Alloy cast iron, fully ribbed, integral with cylinder LUBRICATION SYSTEM – Gear type pump, replaceable spin on oil
frame. filters and industrial base type oil pan, 86 gallon (326 Liters)
CRANKSHAFT – Drop forged alloy steel, dynamically balanced and capacity. Engine mounted shell and tube oil cooler, thermostatic
fully counterweighted. Viscous vibration dampener. valve for oil temperature control, and prelube pump.
CYLINDERS – Removable wet type liners of centrifugally cast alloy MOUNTING – Base type oil pan.
iron. PAINT – Oilfield orange.
CYLINDER HEADS – Twelve interchangeable, valve–in–head type, PISTONS – Aluminum alloy, three ring, with patented high turbulence
with two hard faced intake and two hard faced exhaust valves per combustion bowl. Oil jet cooled with full floating piston pin. High
cylinder. Replaceable intake and exhaust valve seats. Mechanical Compression Ratio (HCR) pistons. 11:1
valve lifters with pivoted roller followers. TURBOCHARGER – Two exhaust driven, dry type with wastegate.
ENGINE ROTATION – Counterclockwise when facing flywheel. For 1400 – 1800 rpm applications.
EXHAUST SYSTEM – Water cooled exhaust manifolds. Single outlet
STANDARD EQUIPMENT
AIR CLEANER – Dual, two stage, dry panel type with rain shield and FLYWHEEL HOUSING – SAE #00, nodular iron housing. Provision
service indicator. Engine mounted. for two magnetic pickups.
BARRING DEVICE – Manual. GOVERNOR – Woodward PSG hydraulic.
BREATHER – Crankcase, closed type (mounted). IGNITION – Waukesha Custom Engine Control electronic ignition
CARBURETOR – Two natural gas Impco 600 varifuel downdraft. system with coils, cables and spark plugs. Non–shielded. 24V DC
CONNECTING RODS – Drop forged alloy steel, angle split, serrated power required. Includes emergency stop/service engine protection
joint, oil jet piston pin lubrication. switch for local override of remote controls.
COOLING SYSTEM – Jacket water: gear driven jacket water pump, INTERCOOLER – Two pass, fin and tube, air–to–water.
thermostatically controlled, full flow bypass type with nominal 180° F LIFTING EYES – For engine only.
(82° C) outlet temperature. 4” ANSI flange connection. Auxiliary water: LUBRICATION SYSTEM – Gear type pump, replaceable spin on oil
thermostatically controlled, gear driven pump supplies water to filters and industrial base type oil pan, 113 gallon (428 Liters)
intercooler and oil cooler circuit. 2” special companion flanges capacity. Engine mounted shell and tube oil cooler, thermostatic
supplied. valve for oil temperature control, and prelube pump. Customer
CRANKCASE – Alloy cast iron, fully ribbed, integral with cylinder supplied prelube pump motor frame size must conform to frame size
frame. 56C and “M” drive configuration.
CRANKSHAFT – Drop forged alloy steel, dynamically balanced and MOUNTING – Base type oil pan.
fully counterweighted. Viscous vibration dampener. PAINT – Oilfield orange.
CYLINDERS – Removable wet type liners of centrifugally cast alloy PISTONS – Aluminum alloy, three ring, with deep central combustion
iron. bowl. Oil jet cooled with full floating piston pin. 8.6:1 compression
CYLINDER HEADS – Sixteen interchangeable, valve–in–head type, ratio.
with two hard faced intake and two hard faced exhaust valves per TURBOCHARGER – Two exhaust driven, dry type with wastegate.
cylinder. Replaceable intake and exhaust valve seats. Mechanical For 1400 – 1800 rpm applications.
valve lifters with pivoted roller followers. It is the customer’s responsibility
ENGINE ROTATION – Counterclockwise when facing flywheel. to provide the necessary
equipment to protect the engine
EXHAUST SYSTEM – Water cooled exhaust manifolds. Single outlet
from low oil pressure, high water temperature and overspeed
flange for ANSI 10” 125# flange.
conditions. Deltec Fuel system requires a shutoff valve that opens
FLYWHEEL – With 165 tooth ring gear (for Delco electric and air/gas upon cranking and closes whenever engine rotation ceases. Failure
starters). Flywheel machined to accept SAE 620D–21, 21˝ (533 mm) to provide the valve will cause an explosive environment resulting in
diameter clutch, or SAE J927B–210 flywheel converter. severe personal injury.
P48GSID TURBOCHARGED AND INTERCOOLED GAS ENGINE FOR LOW FUEL PRESSURE
5.98 Inch (152 mm) Bore x 6.50 Inch (165 mm) Stroke – 16 Cylinders
2,923 Cubic Inch (48 Liter) Displacement
STANDARD EQUIPMENT
AIR CLEANER – Dual, two stage, dry panel type with rain shield and FLYWHEEL HOUSING – SAE #00, nodular iron housing. Provision
service indicator. Engine mounted. for two magnetic pickups.
BARRING DEVICE – Manual. GOVERNOR – Woodward PSG hydraulic.
BREATHER – Crankcase, closed type (mounted). IGNITION – Waukesha Custom Engine Control electronic ignition
CARBURETOR – Two natural gas Deltec carburetors. Mounted system with coils, cables and spark plugs. Non–shielded. 24V DC
before turbochargers for low fuel pressure. Includes speed switch power required. Includes emergency stop/service engine protection
and solenoid that opens upon cranking and closes when engine switch for local override of remote controls.
rotation ceases. INTERCOOLER – Two pass, fin and tube, air–to–water.
CONNECTING RODS – Drop forged alloy steel, angle split, serrated LIFTING EYES – For engine only.
joint, oil jet piston pin lubrication. LUBRICATION SYSTEM – Gear type pump, replaceable spin on oil
COOLING SYSTEM – Jacket water: gear driven jacket water pump, filters and industrial base type oil pan, 113 gallon (428 Liters)
thermostatically controlled, full flow bypass type with nominal 180° F capacity. Engine mounted shell and tube oil cooler, thermostatic
(82° C) outlet temperature. 4” ANSI flange connection. Auxiliary water: valve for oil temperature control, and prelube pump. Customer
supplied prelube pump motor frame size must conform to frame size
thermostatically controlled, gear driven pump supplies water to
56C and “M” drive configuration.
intercooler and oil cooler circuit. 2” special companion flanges
MOUNTING – Base type oil pan.
supplied.
PAINT – Oilfield orange.
CRANKCASE – Alloy cast iron, fully ribbed, integral with cylinder
PISTONS – Aluminum alloy, three ring, with deep central combustion
frame.
bowl. Oil jet cooled with full floating piston pin. 8.6:1 compression
CRANKSHAFT – Drop forged alloy steel, dynamically balanced and
ratio.
fully counterweighted. Viscous vibration dampener.
TURBOCHARGER – Two exhaust driven, dry type with wastegate.
CYLINDERS – Removable wet type liners of centrifugally cast alloy
For 1400 – 1800 rpm applications.
iron.
CYLINDER HEADS – Sixteen interchangeable, valve–in–head type, It is the customer’s responsibility to
with two hard faced intake and two hard faced exhaust valves per provide the necessary equipment to
protect the engine from low oil
cylinder. Replaceable intake and exhaust valve seats. Mechanical
pressure, high water temperature and overspeed conditions. Deltec
valve lifters with pivoted roller followers. Fuel system requires a shutoff valve that opens upon cranking and
ENGINE ROTATION – Counterclockwise when facing flywheel. closes whenever engine rotation ceases. Failure to provide the valve
EXHAUST SYSTEM – Water cooled exhaust manifolds. Single outlet will cause an explosive environment resulting in severe personal
flange for ANSI 10” 125# flange. injury.
FLYWHEEL – With 165 tooth ring gear (for Delco electric and air/gas
starters). Flywheel machined to accept SAE 620D–21, 21˝ (533 mm)
diameter clutch, or SAE J927B–210 flywheel converter.
GSID
GLD
GSI
GL
FUEL SYSTEM
2024A X X One Gas Regulator – Fisher 66Z, (3˝ flange). Gas inlet pressure 8˝ W.C. – 2.5 psig. Shipped
loose .............................................................................................................................................
2025A X X One Gas Regulator – Fisher 66Z, (2˝ NPT). Gas inlet pressure 2.5 – 5 psig. Shipped loose. (For
gas pressure above 5 psi, a step down regulator is required.) ..................................................
2027 X X Gas Regulator – Fisher Y692, for natural gas only. Gas inlet pressure 25 – 50 psig. Mounted ....
2078 X X Solenoid Valve – 2˝, 24V DC, normally closed, shipped loose. For use with fuels that do not
contain sulfur compounds. Maximum pressure: 50 psi ................................................................
Deltec fuel system requires a shutoff valve that opens
upon cranking and closes whenever engine rotation
ceases. Failure to provide the valve will cause an
explosive environment resulting in severe personal injury.
IGNITION
3314A X X X X Waukesha Custom Engine Control Electronic Ignition System – Components meet CSA Class I,
Division 2, Group D, hazardous location requirements ..............................................................
COOLING
4281C X X X X Jacket Water Preheater – Thermostatically controlled, (100° F on; 120° F off), 240V AC, single
phase, 9000 watts ........................................................................................................................
4287 X X X X High Temperature Thermostats: Omits standard thermostats and adds high temperature
thermostats for operation up to 210° F (99° C). Recommended for Digester/Landfill fuel
systems ..........................................................................................................................................
LUBRICATION
5022 X X X X Kenco Oil Level Regulator for standard pan. Meets Canadian Standards Association Class 1,
Division 2, Group B, C & D hazardous location requirements. ...................................................
5112A X X X X Waukesha MICROSPIN Oil Filtration System – Includes mounted MICROSPIN centrifugal
bypass oil filter with shutoff valve. ...............................................................................................
5206 X X X X Prelube Pump Motor – Engine mounted, designed for indoor duty. Continuous prelube not
available. Pump motor: 230V AC, single phase, 50/60 Hz. Rated ¾ hp, 950-1200 rpm. ......
5208 X X X X Prelube Pump Motor – Engine mounted, designed for indoor duty. Continuous duty not
available. Pump motor: 24V DC. ...............................................................................................
CONTROLS
6181B X X X X Woodward EG-3P – Electrohydraulic governor actuator. Requires appropriate control, Ref:
Codes 6184D. Includes magnetic pickup unit, Code 6190 .........................................................
6184D X X X X Governor Control – Woodward 2301E, 24V DC, load sharing digital speed control for
isochronous operation of multiple units or a single unit stand alone or in parallel with utility. For
use with Code 6181B. Meets Canadian Standards Association non-hazardous (ordinary)
location requirements. Shipped loose ...........................................................................................
6190 X X X X Magnetic Pickup Unit – Mounted, included in Code 6181B .............................................................
6254A X X X X Speed Control, Air Actuator – Westinghouse A2H (3 – 15 psi) for PSG governor .........................
INSTRUMENTS
6410B X X X X Instrument Panel – Engine mounted. Includes oil pressure switch gauge, oil temperature switch
gauge, jacket water temperature switch gauge, intake manifold temperature switch gauge and
intake manifold pressure gauge ....................................................................................................
NOTE: All switch gauges and gauges are NOT wired by Waukesha.
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. July 2022
PAGE ENG VGF-36
GSID
GLD
GSI
Code GL MODEL P48 GL, GLD, GSI, GSID ACCESSORIES
6531B X X X X Exhaust Thermocouples – 16 Individual cylinder, K–type thermocouples, plus two pre turbine
and one post turbine (19 total). Wired and terminated at engine mounted junction box ...........
6538 X X X X Hourmeter/Tachometer/Overspeed Combination – Digital electronic, includes magnetic pickup
unit. Panel mounted. Requires Code 6410B ...............................................................................
MISCELLANEOUS
9974Q X X X X Engine/Enginator that is Customs Union Compliant (Russia, Belarus, and Kazakhstan). Includes
SERIAL NUMBER SPECIFIC Technical Passport & Safety Justification in Russian and English,
Engine Operator's Manuals (one in Russian and one in English), and EAC label on
unit. Enginators include supplied equipment manuals that are in English only. May require
additional lead time, consult factory for delivery information.........................................................
9974U X X X X Engine that is CE Mark Compliant. Includes a SERIAL NUMBER SPECIFIC Declaration of
Incorporation and Operator's Manual both in English. It is the responsibility of the entity
(Packager, Distributor..) placing the complete package on the European market to ensure that
the final complete package (machine) is properly CE Marked and that the final customer is
provided with the required translated manuals. Waukesha can assist with translations at
additional cost, contact Applications/Sales ...................................................................................
9974W X X X X Required label for Hazardous Location CSA Certification in US & Canada end use. Adds a safety
label containing English and French language that is required to comply with the certification
terms of the equipment. For use with code 3314A. Note: For end uses classified as Hazardous
Locations Division 2 and in US & Canada. Contact Application Engineering for use in other
countries. ........................................................................................................................................
9998 X X X X Shipping Skid – For Overseas Container........................................................................................................
EXTENDED WARRANTY
16-Cylinder VGF Engine Extended Warranty -- 1 Year. Extended warranty excludes wear items
10006AA X X X X
and includes only warrantable items as defined in Express Limited Warranty (ELW). Must be
purchased at time of original order. If applicable, the proper deferral process and preservation
as outlined in Service Bulletin 16-1855H (or most current) and WEDA 542 (or most current)
must be followed or warranty extension is void. ...........................................................................
16-Cylinder VGF Engine Extended Warranty -- 2 Years. Extended warranty excludes wear items
10006BB X X X X
and includes only warrantable items as defined in Express Limited Warranty (ELW). Must be
purchased at time of original order. If applicable, the proper deferral process and preservation
as outlined in Service Bulletin 16-1855H (or most current) and WEDA 542 (or most current)
must be followed or warranty extension is void. ...........................................................................
16-Cylinder VGF Engine Extended Warranty -- 3 Years. Extended warranty excludes wear items
10006CC X X X X
and includes only warrantable items as defined in Express Limited Warranty (ELW). Must be
purchased at time of original order. If applicable, the proper deferral process and preservation
as outlined in Service Bulletin 16-1855H (or most current) and WEDA 542 (or most current)
must be followed or warranty extension is void. ...........................................................................
DISCLAIMER
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. July 2022
PAGE ENG VGF-37
P48SE – 60Hz TURBOCHARGED AND INTERCOOLED GAS ENGINE FOR LOW FUEL PRESSURE
5.98 Inch (152 mm) Bore x 6.50 Inch (165 mm) Stroke – 16 Cylinders
2,923 Cubic Inch (48 Liter) Displacement
STANDARD EQUIPMENT
AIR CLEANER – Two high efficiency, replaceable elements and ENGINE MONITORING DEVICES – Factory-mounted sensors and
service indication. For indoor installations. harnessing for post-filter lube oil pressure, oil temperature, intake
AIR FUEL RATIO CONTROL (AFR) –integrates with ESM2 for manifold temperature, intake manifold pressure (2), boost pressure
enhanced rich-burn engine control. Utilizes fuel control valve and (2), jacket water temperature, post turbine exhaust temperature, and
enhanced pre-catalyst O2 sensor optimized for gaseous fuels for exhaust O2 content, all accessible through the ESM2 interface.
stable operation. ESM2 continually monitors combustion performance through
BARRING DEVICE – Manual. individual knock sensors to provide detonation protection. Includes
BEARINGS – Heavy duty, replaceable, precision type. adjustable oil pressure permissive prior to start signal. Dual
BREATHER – Crankcase, closed type (mounted). magnetic pick-ups are used for accurate engine speed monitoring.
CARBURETOR – Two natural gas Impco 600D carburetors. Mounted ESM2 provides diagnostics information related to engine
before turbochargers for low fuel pressure. performance and sensor validity.
CATALYST: Loose-ship three-way catalyst included as standard ENGINE ROTATION – Counterclockwise when facing flywheel.
equipment with P6580S13. Sealed, non-replaceable element with EXHAUST SYSTEM – Water cooled exhaust manifolds. Single outlet
option code 1300. flange for ANSI 10” 125# flange.
CONNECTING RODS – Drop forged alloy steel, angle split, serrated FLYWHEEL – With 165 tooth ring gear. Flywheel machined to accept
joint, oil jet piston pin lubrication. SAE 620D–21, 21˝ (533 mm) diameter clutch, or SAE J927B–210
CONTROL SYSTEM - Waukesha Engine System Manager 2 (ESM2*) flywheel converter.
integrates spark timing control, speed governing, detonation FLYWHEEL HOUSING – SAE #00, nodular iron housing. Provision
protection, misfire detection, start-stop control, diagnostic for magnetic pickup.
information, fault logging, engine safeties and AFR2 (Air/Fuel Ratio) FUEL SYSTEM – Single 3″ flange fuel inlet connection. Two natural
control in one Engine Control Unit (ECU). One customer connection gas Impco 600D carburetors, one engine mounted gas regulator..
to the control system via a 25-foot Customer Interface harness (7.6 1.5-5 psi (1032 kPa) fuel inlet pressure required.
m). ESM2 also provides a MODBUS RTU slave RS-485 connection GOVERNOR – Electric throttle actuator controlled by ESM2 with
for integration into local panels. Customer connections are required throttle position feedback.
to the local panel, fuel valve, and 24V DC power supply. Compatible IGNITION – Ignition Power Module Diagnostics (IPMD) - controlled
with Woodward load sharing module. Includes 12” ESM2 Display by ESM2. Optimized ignition energy levels, controlled by ESM2, to
Panel. maximize spark plug life and performance
COOLING SYSTEM – Jacket water: gear driven jacket water pump, INTERCOOLER – Two pass, fin and tube, air–to–water.
thermostatically controlled, full flow bypass type with nominal 180° F LIFTING EYES – For engine only.
LUBRICATION SYSTEM – Gear type pump, replaceable spin on oil
(82° C) outlet temperature. 4” ANSI flange connection. Auxiliary water:
filters and industrial base type oil pan, 113 gallon (428 Liters)
thermostatically controlled, gear driven pump supplies water to
capacity. Engine mounted shell and tube oil cooler, thermostatic
intercooler and oil cooler circuit. 2” special companion flanges
valve for oil temperature control.
supplied.
MOUNTING – Base type oil pan.
CRANKCASE – Alloy cast iron, fully ribbed, integral with cylinder
PAINT – Oilfield orange.
frame.
PISTONS – Aluminum alloy, three ring, with deep central combustion
CRANKSHAFT – Drop forged alloy steel, dynamically balanced and
bowl. Oil jet cooled with full floating piston pin. 8.6:1 compression
fully counterweighted. Viscous vibration dampener.
ratio.
CYLINDERS – Removable wet type liners of centrifugally cast alloy
STARTING SYSTEM – Single 24V DC electric starting motor. Dual
iron.
starters optional
CYLINDER HEADS – Sixteen interchangeable, valve–in–head type
TURBOCHARGER – Two exhaust driven, dry type with wastegate.
with four valves per cylinder including rotators. Replaceable intake
For 1800 rpm applications.
and exhaust valve seats. Mechanical valve lifters with pivoted roller
followers. Flange mounted ignition coils.
DISPLAY PANEL, ESM2 – ESM2 Display Panel comes standard and
is a required part of the ESM2 system, allowing for user parameter
adjustments, fault information viewing and continuous data logging
capability over the lifetime of the product. The standard ESM2
Display Panel is a 12” (0.3m) resistive-touch full-color display,
incorporating service tool functionality, on-screen E-Help
troubleshooting information for ESM2 faults, and technical
documentation such as manuals and service bulletins. The ESM2
HMI is shipped loose and mounted in the customer control panel.
P6580S13
COOLING
X X 4281C Jacket Water Preheater – Thermostatically controlled, (100° F on; 120° F off), 240V AC, single phase, 9000
watts ........................................................................................................................................................
LUBRICATION
X X 5022 Kenco Oil Level Regulator for standard pan. Meets Canadian Standards Association Class 1, Division 2,
Group B, C & D hazardous location requirements..................................................................................
X X 5112A Waukesha MICROSPIN Oil Filtration System – Includes mounted MICROSPIN centrifugal bypass oil filter
with shutoff valve. .....................................................................................................................................
X X 5206 Prelube Pump & Motor – Engine mounted, designed for indoor duty. Continuous prelube not available.
Pump motor: 230V AC, single phase, 50/60 Hz. Rated ¾ hp, 950-1200 rpm .................. ………...
X X 5208 Prelube Pump & Motor – Engine mounted, designed for indoor duty. Continuous duty not available. Pump
motor: 24V DC. .....................................................................................................................................
INSTRUMENTS
X X 6190 Magnetic Pickup Unit – Mounted
X X 6531B Exhaust Thermocouples – 16 Individual cylinder, K–type thermocouples, plus two pre turbine and one
post turbine (19 total). Wired and terminated at engine mounted junction box ......................................
X X 6650D ESM2 customer interface harness 50ft. Replaces standard 25 ft. harness ………………………………….
X X 6650GG ESM2 customer interface harness 100ft. Replaces standard 25ft harness………………………………….
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. July 2022
PAGE MF-1
mobileFLEX models are EPA certified for stationary per 40 CFR 60 subpart JJJJ and non-road per 40 CFR 1048.
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. July 2022
PAGE MF-2
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. July 2022
PAGE MF-3
F18SE TURBOCHARGED AND INTERCOOLED GAS ENGINE FOR MOBILE APPLICATIONS, EPA CERTIFIED
(Tier 2 Certified Per 40 CFR 1048)
5.98 Inch (152 mm) Bore x 6.50 Inch (165 mm) Stroke – 6 Cylinders, 1096 Cubic Inch (18 Liter) Displacement
STANDARD EQUIPMENT
AIR CLEANER – Two Stage, dry panel type with rain shield and ELECTRONIC SERVICE PROGRAM (ESP) – Microsoft Windows-
service indicator. Engine mounted. based program provided on CD-ROM for programming and
AIR/FUEL RATIO CONTROL – 2nd generation AFR2 integrates with interface to ESM. Includes E-Help for troubleshooting any ESM
ESM for enhanced rich-burn engine control. Utilizes fuel control valve faults. Serial harness is provided for connection of a customer
between regulator and carburetor and enhanced pre-catalyst O2 supplied laptop to the ECU RS-232 port.
sensor optimized for gaseous fuels for more stable operation through ENGINE MONITORING DEVICES – Factory mounted and wired
sensors for lube oil pressure and temperature, intake manifold
fuel swings. Emission Control System adds 3-way catalyst sized EPA
temperature and pressure, and jacket water temperature, all
Tier II NG emissions, certified per 40 CFR 1048 for mobile & stationary
accessible through ESM*. Dual magnetic pick-ups are used for
applications. Stainless steel housing includes 2 elements. Pre- and
accurate engine speed monitoring. ESM provides predictive spark
post-catalyst temperature for simplified maintenance and emission plug diagnostics as well as advanced diagnostics of engine and all
reporting. Standard AFR2 control system meets Canadian Standards ESM sensors and logs any faults into non-volatile flash memory.
Association Class 1, Division 2, Group A, B, C, & D (Canada & US) Sensors meet Canadian Standards Association Class 1, Division 2,
hazardous location requirements Group A, B, C, & D (Canada & US) hazardous location
BARRING DEVICE – Manual. requirements.
BEARINGS – Heavy duty, replaceable, precision type. ENGINE ROTATION – Counterclockwise when facing flywheel.
BREATHER – Self-regulating, closed system. EXHAUST SYSTEM – Water cooled exhaust manifold, Outlet flange
CARBURETOR – Single natural gas Impco 600. for ANSI 8” 125# flange.
CONNECTING RODS – Drop forged alloy steel, angle split, serrated FLYWHEEL – With 150 tooth ring gear (for Delco electric and air/gas
joint, oil jet piston pin lubrication. starters). Flywheel machined to accept SAE 620D, 18” (457 mm)
CONTROL SYSTEM – Waukesha Engine System Manager (ESM) diameter clutch.
integrates spark timing control, speed governing, detonation FLYWHEEL HOUSING – SAE #0, nodular iron housing. Provision for
detection, start-stop control, diagnostic tools, fault logging and engine two magnetic pickups and vertical mounting pads.
safeties. Engine Control Unit (ECU) is central brain of the control FUEL SYSTEM – Single 2″ NPT fuel inlet connection. One natural gas,
system and main customer interface. Interface with ESM is through updraft carburetor and one engine mounted gas regulator, 1.5-5 psi (10-
25 foot (7.6 m) harness to local panel, through MODBUS RTU slave 32 kPa) fuel inlet pressure required. Prewired for ESM control of factory
connection RS-485 multidrop hardware, digital & analog I/O and supplied fuel shutoff valve.
through the Electronic Service Program (ESP). Customer connections GOVERNOR – Electric throttle actuator controlled by ESM with throttle
are only required to the local panel and 24V DC power supply. position feedback. Governor tuning is performed using ESP. ESM
Compatible with Woodward load sharing module. ESM meets includes option of a load-coming feature to improve engine response to
Canadian Standards Association Class I, Division 2, Group A, B, C & step loads.
D (Canada & US) hazardous location requirements. IGNITION SYSTEM – Ignition Power Module (IPM) controlled by ESM,
COOLING SYSTEM – Jacket water: gear driven jacket water pump, with spark timing optimized for any speed-load condition. Dual voltage
thermostatically controlled, full flow bypass type with nominal 200° F energy levels automatically controlled by ESM to maximize spark plug
(93° C) outlet temperature. Flange connections for (1) 3” (76.2mm) life. Shielded ignition components meet Canadian Standard Association
inlet and outlet. Auxiliary water: thermostatically controlled, gear Class 1, Division 2, Group A, B, C & D (Canada & US) hazardous location
driven pump supplies water to intercooler and oil cooler circuit. NPT requirements.
connections for (1) 2” (50.8mm) inlet and (1) 1.5” (38.1mm) outlet. INTERCOOLER – Air–to–water.
CRANKCASE – Alloy cast iron, fully ribbed, integral with cylinder LIFTING EYES – For engine only.
frame. LUBRICATION SYSTEM – Gear type pump, full flow spin–on filters
CRANKSHAFT – Drop forged alloy steel, dynamically balanced and and industrial base type oil pan, 44 gallon (166 liters) capacity,
fully counterweighted. Viscous vibration dampener. including filters. Engine mounted plate type oil cooler and centrifugal
CYLINDERS – Removable wet type liners of centrifugally cast alloy bypass filter.
iron. MOUNTING – Base type oil pan.
CYLINDER HEADS – Six interchangeable, valve–in–head type with PAINT – Oilfield orange topcoat.
four valves per cylinder including rotators. Replaceable intake and PISTONS – Aluminum alloy, three ring, with deep central combustion
exhaust valve seats. Mechanical valve lifters with pivoted roller bowl. Oil jet cooled with full floating piston pin. 8.6:1 compression
followers. Flange mounted ignition coils. ratio.
DISPLAY PANEL – Waukesha-supplied full-color programmable TURBOCHARGER – Exhaust driven, dry type with differential wastegate.
display panel for engine parameter readout and emPact Emission For 1400 – 1800 rpm applications.
Control System calibration, including engine fault/shutdown
VIBRATION DAMPER – Viscous type.
information and data logging via USB connection. Simple installation
THREE WAY CATALYST (TWC) - The Waukesha converter is a dual
with MODBUS RS485 communications allowing seamless package
element design for use with Waukesha gas engines. Its removable
controller communications. 480x272 graphic backlit color display with
cover allows easy access for maintenance and catalyst element
key-press navigation. Meets CSA Class I, Div 2, Groups B, C, and D.
replacement. Inlet/Outlet flange dia 8”, thickness 0.5”, Overall
Supports the following languages: English, Spanish, French, German,
length 28.13”, Square form box construction, 21.71in wide, weight
Russian, Arabic, Chinese and Portuguese. Connects via customer
195.52 lbs. (88.69 kg). Includes Flex, bolting and additional
interface harness
hardware.
H24SE TURBOCHARGED AND INTERCOOLED, GAS ENGINE FOR MOBILE APPLICATIONS, EPA CERTIFIED
(Tier 2 Certified Per 40 CFR 1048)
5.98 Inch (152 mm) Bore x 6.50 Inch (165 mm) Stroke – 8 Cylinders, 1,462 Cubic Inch (24 Liter) Displacement
STANDARD EQUIPMENT
AIR CLEANER – Two Stage, dry panel type with rain shield and ELECTRONIC SERVICE PROGRAM (ESP) – Microsoft Windows-
service indicator. Engine mounted. based program provided on CD-ROM for programming and
AIR/FUEL RATIO CONTROL – 2nd generation AFR2 integrates with interface to ESM. Includes E-Help for troubleshooting any ESM
ESM for enhanced rich-burn engine control. Utilizes fuel control valve faults. Serial harness is provided for connection of a customer
between regulator and carburetor and enhanced pre-catalyst O2 supplied laptop to the ECU RS-232 port.
sensor optimized for gaseous fuels for more stable operation through ENGINE MONITORING DEVICES – Factory mounted and wired
sensors for lube oil pressure and temperature, intake manifold
fuel swings. Emission Control System adds 3-way catalyst sized EPA
temperature and pressure, and jacket water temperature, all
Tier II NG emissions, certified per 40 CFR 1048 for mobile & stationary
accessible through ESM*. Dual magnetic pick-ups are used for
applications. Stainless steel housing includes 2 elements. Pre- and
accurate engine speed monitoring. ESM provides predictive spark
post-catalyst temperature for simplified maintenance and emission plug diagnostics as well as advanced diagnostics of engine and all
reporting. Standard AFR2 control system meets Canadian Standards ESM sensors and logs any faults into non-volatile flash memory.
Association Class 1, Division 2, Group A, B, C, & D (Canada & US) Sensors meet Canadian Standards Association Class 1, Division 2,
hazardous location requirements Group A, B, C, & D (Canada & US) hazardous location
BARRING DEVICE – Manual. requirements.
BREATHER – Self-regulating, closed system. ENGINE ROTATION – Counterclockwise when facing flywheel.
CARBURETOR – Single natural gas Impco 400. EXHAUST SYSTEM – Water cooled exhaust manifold, Outlet flange
CONNECTING RODS – Drop forged alloy steel, angle split, serrated for ANSI 8” 125# flange.
joint, oil jet piston pin lubrication. FLYWHEEL – With 150 tooth ring gear (for Delco electric and air/gas
CONTROL SYSTEM – Waukesha Engine System Manager (ESM) starters). Flywheel machined to accept SAE 620D, 18” (457 mm)
integrates spark timing control, speed governing, detonation diameter clutch.
detection, start-stop control, diagnostic tools, fault logging and engine FLYWHEEL HOUSING – SAE #0 nodular iron housing. Provision for
safeties. Engine Control Unit (ECU) is central brain of the control two magnetic pickups and vertical mounting pads.
system and main customer interface. Interface with ESM is through FUEL SYSTEM – Single 2″ NPT fuel inlet connection. One natural gas,
25 foot (7.6 m) harness to local panel, through MODBUS RTU slave updraft carburetor and one engine mounted gas regulator, 1.5-5 psi
connection RS-485 multidrop hardware, and through the Electronic (1032 kPa) fuel inlet pressure required. Prewired for ESM control of
Service Program (ESP). Customer connections are only required to factory supplied fuel shutoff valve.
the local panel, fuel valve, and 24V DC power supply. Compatible with GOVERNOR – Electric throttle actuator controlled by ESM with throttle
Woodward load sharing module. ESM meets Canadian Standards position feedback. Governor tuning is performed using ESP. ESM
Association Class I, Division 2, Group A, B, C & D (Canada & US) includes option of a load-coming feature to improve engine response to
hazardous location requirements. step loads.
COOLING SYSTEM – Jacket water: gear driven pump, IGNITION SYSTEM – Ignition Power Module (IPM) controlled by ESM,
thermostatically controlled, full flow bypass type with nominal 200° with spark timing optimized for any speed-load condition. Dual voltage
F (93° C) outlet temperature. Auxiliary water: thermostatically energy levels automatically controlled by ESM to maximize spark plug
controlled, gear driven pump supplies water to intercooler and oil life. Shielded ignition components meet Canadian Standard Association
cooler circuit. Class 1, Division 2, Group A, B, C & D (Canada & US) hazardous location
CRANKCASE – Alloy cast iron, fully ribbed, integral with cylinder requirements.
frame. INTERCOOLER – Air–to–water.
CRANKSHAFT – Drop forged alloy steel, dynamically balanced and LIFTING EYES – For engine only.
fully counterweighted. Viscous vibration dampener. LUBRICATION SYSTEM – Gear type pump, full flow spin–on filters
CYLINDERS – Removable wet type liners of centrifugally cast alloy and industrial base type oil pan, 56 gallon (212 Liters) capacity,
iron. including filters. Engine mounted plate type oil cooler.
CYLINDER HEADS – Eight interchangeable, valve–in–head type, MOUNTING – Base type oil pan.
with two hard faced intake and two hard faced exhaust valves per PAINT – Oilfield orange.
cylinder. Replaceable intake and exhaust valve seats. Mechanical PISTONS – Aluminum alloy, three ring, with deep central combustion
valve lifters with pivoted roller followers.
bowl. Oil jet cooled with full floating piston pin. 8.6:1 compression
DISPLAY PANEL – Waukesha-supplied full-color programmable
ratio.
display panel for engine parameter readout and emPact Emission
TURBOCHARGER – Exhaust driven, dry type with wastegate. For
Control System calibration, including engine fault/shutdown
1350 – 1800 rpm applications.
information and data logging via USB connection. Simple installation
with MODBUS RS485 communications allowing seamless package THREE WAY CATALYST (TWC) - The Waukesha converter is a dual
controller communications. 480x272 graphic backlit color display with element design for use with Waukesha gas engines. Its removable
key-press navigation. Meets CSA Class I, Div 2, Groups B, C, and D. cover allows easy access for maintenance and catalyst element
Supports the following languages: English, Spanish, French, German, replacement. Inlet/Outlet flange dia 14”, thickness 0.5”, Overall
Russian, Arabic, Chinese and Portuguese. Connects via customer length 45.125”, Banded dia 30 5/16”, approx. weight 332 lbs.
interface harness Includes Flex, bolting and additional hardware.
VGF SE GAS OIL FIELD POWER GENERATION SKID* FOR MOBILE APPLICATIONS, EPA CERTIFIED
FULLY ASSEMBLED ON TAILBOARD SKID, TRAILER FREINDLY
(Tier 2 Certified Per 40 CFR 1048)
VGF18SE– VGF24SE
BASIC ENGINATOR SPECIFICATIONS
AIR CLEANER – Two stage, dry panel type with rain shield and key-press navigation. Meets CSA Class I, Div 2, Groups B, C, and D.
service indicator. Engine mounted. Supports the following languages: English, Spanish, French, German,
AIR/FUEL RATIO CONTROL – 2nd generation AFR2 integrates with Russian, Arabic, Chinese and Portuguese. Connects via customer
ESM for enhanced rich-burn engine control. Utilizes fuel control valve interface harness
between regulator and carburetor and enhanced pre-catalyst O2 ELECTRONIC SERVICE PROGRAM (ESP) – Microsoft Windows-
sensor optimized for gaseous fuels for more stable operation through based program provided on CD-ROM for programming and
fuel swings. Emission Control System adds 3-way catalyst sized EPA interface to ESM. Includes E-Help for troubleshooting any ESM
Tier II NG emissions, certified per 40 CFR 1048 for mobile & stationary faults. Serial harness is provided for connection of a customer
applications. Stainless steel housing includes 2 elements. Pre- and supplied laptop to the ECU RS-232 port.
post-catalyst temperature for simplified maintenance and emission ENGINE MONITORING DEVICES – Factory mounted and wired
reporting. Standard AFR2 control system meets Canadian Standards sensors for lube oil pressure and temperature, intake manifold
temperature and pressure, and jacket water temperature, all
Association Class 1, Division 2, Group A, B, C, & D (Canada & US)
accessible through ESM*. Dual magnetic pick-ups are used for
hazardous location requirements. TWC and Exhaust Silencer fully
accurate engine speed monitoring. ESM provides predictive spark
mounted in skid frame.
plug diagnostics as well as advanced diagnostics of engine and all
BARRING DEVICE – Manual. ESM sensors and logs any faults into non-volatile flash memory.
BASE – Engine, generator, radiator, TWC, Controls and exhaust Sensors meet Canadian Standards Association Class 1, Division 2,
silencer are mounted and aligned on a welded structural steel base Group A, B, C, & D (Canada & US) hazardous location
and 3 point mounted to an oilfield tailboard skid. Base is equipped requirements.
with lifting eyes. ENGINE ROTATION – Counterclockwise when facing flywheel.
BATTERY BOX - High density polyurethane construction with a EXHAUST – Water–cooled, cast iron exhaust manifold. Single vertical
protective cover. Holds batteries, batteries not included. Shipped flexible stainless steel exhaust connection with ANSI 125# 8” flange.
loose. FUEL SYSTEM – Single 2″ NPT fuel inlet connection. One natural gas,
BREATHER – Self-regulating, closed system. updraft carburetor and one engine mounted gas regulator, 1.5-5 psi
CONNECTING RODS – Drop forged alloy steel, angle split, serrated (1032 kPa) fuel inlet pressure required. Prewired for ESM control of
joint, oil jet piston pin lubrication. factory supplied fuel shutoff valve.
CONTROL SYSTEM – Waukesha Engine System Manager (ESM) GENERATOR – Open, drip–proof, direct connected, synchronous, fan
integrates spark timing control, speed governing, detonation cooled, AC revolving field type, 2/3 pitch, single bearing generator
detection, start-stop control, diagnostic tools, fault logging and engine with AREP excitation system for 300% short circuit sustain for 10
safeties. Engine Control Unit (ECU) is central brain of the control seconds (250% for 50 Hz) and motor starting. TIF and Deviation
system and main customer interface. Interface with ESM is through Factor within NEMA MG–1.32. Voltage: 480/277, 3 phase, 12 wire
25-foot (7.6 m) harness to local panel, through MODBUS RTU slave Wye, 60 Hz, and 400/230, 3 phase, 12 wire Wye, 50 Hz.
connection RS-485 multidrop hardware, and through the Electronic Temperature rise within NEMA 80°C OVER 40°C. Voltage
Service Program (ESP). Customer connections are only required to
regulation is ± 0.5%. All generators are rated at 0.8 power factor,
the local panel, fuel valve, and 24V DC power supply. Compatible with
are mounted on the engine flywheel housing, and have multiple
Woodward load sharing module. ESM meets Canadian Standards
steel disc flexible coupling drive.
Association Class I, Division 2, Group A, B, C & D (Canada & US)
GOVERNOR – Electric throttle actuator controlled by ESM with throttle
hazardous location requirements.
position feedback. Governor tuning is performed using ESP. ESM
COOLING SYSTEM – Thermostatically controlled. Mounted radiator
includes option of a load-coming feature to improve engine response to
with core guard, duct adapter and belt driven suction fan sized for
step loads.
110° F (43° C) ambient air and 50% ethylene glycol coolant solution.
IGNITION SYSTEM – Ignition Power Module (IPM) controlled by
CRANKCASE – Alloy cast iron, fully ribbed, integral with cylinder
ESM, with spark timing optimized for any speed-load condition. Dual
frame.
voltage energy levels automatically controlled by ESM to maximize
CRANKSHAFT – Drop forged alloy steel with thru hardened journals,
spark plug life. Shielded ignition components meet Canadian
dynamically balanced and fully counterweighted. Viscous vibration
Standard Association Class 1, Division 2, Group A, B, C & D (Canada
dampener.
& US) hazardous location requirements
CYLINDER HEADS – Individual, interchangeable valve–in–head type
INTERCOOLER – Air–to–water.
with deep section alloy casting. Two hard–faced intake and two
JUNCTION BOXES – Separate AC & DC junction boxes for engine
hard–faced exhaust valves per cylinder. Replaceable intake and
wiring and external connections.
exhaust valve seats. Mechanical valve lifters with pivoted roller
LUBRICATION SYSTEM – Gear type pump, full flow spin–on filters
followers.
and industrial base type oil pan plus bypass centrifugal filter. Engine
CYLINDERS – Removable wet type liners of centrifugally cast alloy
mounted plate type oil cooler. Lubricating oil level regulator. Kenco
iron.
model LCE with explosion-proof electric low level SPDT safety
DISPLAY PANEL – Waukesha-supplied full-color programmable
switch and Fire Safe features. Meets CSA Class I, Division 2, Group
display panel for engine parameter readout and emPact Emission
Control System calibration, including engine fault/shutdown B, C, & D requirements.
information and data logging via USB connection. Simple installation
with MODBUS RS485 communications allowing seamless package
controller communications. 480x272 graphic backlit color display with
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. July 2022
PAGE MF-6
VGF SE GAS OIL FIELD POWER GENERATION SKID* FOR MOBILE APPLICATIONS, EPA CERTIFIED
FULLY ASSEMBLED ON TAILBOARD SKID, TRAILER FREINDLY
(Tier 2 Certified Per 40 CFR 1048)
VGF18SE– VGF24SE
PAINT – Oilfield Orange. WATER CIRCULATING SYSTEM, AUXILIARY CIRCUIT – Gear driven
PISTONS – Aluminum alloy, three ring, with patented high turbulence pump for intercooler and oil cooler. Inlet temperature of 130° F (54° C)
combustion bowl. Oil jet cooled with full floating piston pin. for all models.
STARTING SYSTEM – 24V DC starting motor. WATER CIRCULATING SYSTEM, JACKET WATER CIRCUIT –
SILENCING - Exhaust Silencer – Residential Rating, Sized & 10′′ Gear driven jacket water pump, thermostatically controlled, full flow
flanged, end inlet, end outlet. Fully mounted with TWC in skid frame. bypass type with nominal 200° F (93° C) outlet temperature.
TURBOCHARGER – Dry–type with Differential wastegate. DOCUMENTATION - The following items are supplied as standard
THREE WAY CATALYST (TWC) - The Waukesha converter is a 2- with every order:
element design for use with Waukesha gas engines. Its removable – Electronic notification and access to drawings for review and or
cover allows easy access for maintenance and catalyst element approval.
replacement. Inlet/Outlet flange dia 14”, thickness 0.5”, Overall – One Enginator® manual consisting of:
length 45.125”, Banded dia 30 5/16”, approx. weight 332 lbs. Fully • Engine operation/service manual.
assembled and mounted • Engine parts book.
VOLTAGE REGULATOR – Automatic type • Generator/voltage regulator instructions.
• Instructions on major special items.
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. July 2022
PAGE MF-7
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. July 2022
PAGE MF-8
PAINT – Oilfield Orange. WATER CIRCULATING SYSTEM, AUXILIARY CIRCUIT – Gear driven
PISTONS – Aluminum alloy, three ring, with patented high turbulence pump for intercooler and oil cooler. Inlet temperature of 130° F (54° C)
combustion bowl. Oil jet cooled with full floating piston pin. for all models.
STARTING SYSTEM – 24V DC starting motor. WATER CIRCULATING SYSTEM, JACKET WATER CIRCUIT –
TURBOCHARGER – Dry–type with Differential wastegate. 180° – 190° F (82° – 88° C) thermostatic temperature regulation.
THREE WAY CATALYST (TWC) - The Waukesha converter is a 2- Gear–driven pump.
element design for use with Waukesha gas engines. Its removable DOCUMENTATION - The following items are supplied as standard
cover allows easy access for maintenance and catalyst element with every order:
replacement. Inlet/Outlet flange dia 14”, thickness 0.5”, Overall – Electronic notification and access to drawings for review and or
length 45.125”, Banded dia 30 5/16”, approx. weight 332 lbs. approval.
VOLTAGE REGULATOR – Automatic type (shipped loose). – One Enginator® manual consisting of:
* Engine operation/service manual.
* Engine parts book.
* Generator/voltage regulator instructions.
* Instructions on major special items.
GENSET
ENGINE
SKID)
FUEL SYSTEM
2022 X X X Gas Regulator: 2” NPT Knockdown regulator for Low Pressure fuel (outlet 3-10 psi / inlet 20-200 psi).
Shipped Loose..............................................................................................................................................
2034D X X X Dual Fuel System: Natural gas/field gas and LP(HD-5). Allows the engine to automatically or manually
switch from natural/field gas to liquid propane (LP) without shutting down. Engine mounted vaporizers,
MAS (valve), pressure relief valve, fuel pressure sensor, and switching solenoids. Switching controls
included. LP fuel pressure 30-300PSIG.See S-07546-40 for further fuel specifications. System engine
mounted. (Contact Application Engineering) ...............................................................................................
AIR CLEANERS
2320D X X X Precleaner, Heavy Duty inertial separator, for standard air cleaner. Removes std. Air cleaner Rain
Shield .......................................................................................................................
NOTE: Precleaners are recommended for applications in dusty environments or when dust conditions
are unpredictable.
ELECTRICAL SYSTEM
Generator Options:
3046 X X Cross Current Compensation – For reactive load control when parallel operation is required. Current
transformer included (shipped loose) (Not Required with ECP8000 Panel) .................................................
ELECTRICAL SYSTEM
Engine Options:
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. July 2022
PAGE MF-9
OFPG (TAILBOARD
GENSET
ENGINE
SKID)
COOLING
4281D X X X Jacket Water Preheater – Thermostatically controlled, (100° F on; 120° F off), 240V AC, single phase,
6000 watts. Customer supplied logic & shipped loose. (Min/Max ambient temperature 4°F – 104°F) ....
LUBRICATION
5022C X X Regulator – Lubricating oil level. Kenco model LCE with explosion-proof electric low level SPDT safety
switch and Fire Safe features. Meets CSA Class I, Division 2, Group B, C, & D requirements. ..............
5205D X X X Prelube Pump – Electric prelube pump for prelube and post lube. Engine mounted. Includes 24V DC
motor driven pre-lube pump. Continuous prelube not available ................................................................
5205E X X X Prelube Pump - Air Driven prelube pump for prelube and post lube. Engine mounted, air/gas motor-
driven. .......................................................................................................................
5205F X X X Prelube Pump – Electric prelube pump for prelube and post lube. Pump Motor engine mounted, Control
Box shipped loose. Designed for indoor duty. Continuous prelube not available. Pump motor: 208-
240V AC, single phase, 50/60 Hz ...............................................................................................................
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. July 2022
PAGE MF-10
OFPG (TAILBOARD
GENSET
ENGINE
SKID)
CONTROLS
6018 X X Load Sharing dongle for multiple units in island operation.............................................................................
6190 X X X Magnetic Pickup Unit – Mounted ....................................................................................................................
6215 X X Sensor Package, includes
- Temps for exhaust (e acyl + pre + post), aux water inlet, fuel, gen windings and bearing
- Pressure for JW and fuel
- Water level – JW and Aux
- Oil Level – High and Low
- Engine Vibration.....................................................................................................................................
6531D X Exhaust Thermocouples, F18 – 6 individual cylinder, K–type thermocouples, plus post turbine TC and
values displayed in HMI via MODBUS (Not available with 6215, already included) ................................
6531E X Exhaust Thermocouples, H24 – 8 individual cylinder, K–type thermocouples, plus post turbine TC and
values displayed in HMI via MODBUS (Not available with 6215, already included) ...............................
6650D X ESM customer interface & option harnesses 50ft. Replaces standard 25 ft. harness. ...............................
6650GG X ESM customer interface & option harnesses 100ft. Replaces standard 25 ft. harness. .............................
MISCELLANEOUS
9974U X Engine that is CE Mark Compliant. Includes a SERIAL NUMBER SPECIFIC Declaration of
Incorporation and Operator's Manual both in English. It is the responsibility of the entity (Packager,
Distributor..) placing the complete package on the European market to ensure that the final complete
package (machine) is properly CE Marked and that the final customer is provided with the required
translated manuals. Waukesha can assist with translations at additional cost, contact
Applications/Sales ........................................................................................................................................
9974V X Enginator that is CE Mark Compliant. Includes CE Mark Label, the following documentation in both
English and language of country of final installation, order to state required language; SERIAL NUMBER
SPECIFIC Declaration of Conformance, Operator, Generator and Voltage Regulator Manuals. All other
supporting documentation is supplied in English only. Contact Applications/Sales if the sale requires
additional translation requirements. May require additional lead time and cost, consult factory for
delivery information. ...................................................................................................................................
9974X X X X Required label for Hazardous Location CSA Certification in US & Canada end use. Adds a safety label
containing English and French language that is required to comply with the certification terms of the
equipment. Note: For end uses classified as Hazardous Locations Division 2 and in US & Canada.
Contact Application Engineering for use in other countries. .....................................................................
9990 X X X Paint Charge for other than Grey or Orange .................................................................................................
EXTENDED WARRANTY
10003AA X 6-Cylinder VGF Engine Extended Warranty -- 1 Year. Extended warranty excludes wear items and
includes only warrantable items as defined in Express Limited Warranty (ELW). Must be purchased at
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. July 2022
PAGE MF-11
OFPG (TAILBOARD
GENSET
ENGINE
SKID)
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. July 2022
PAGE MF-12
OFPG (TAILBOARD
GENSET
ENGINE
SKID)
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. July 2022
PAGE MF-13
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. July 2022
PAGE MF-14
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. July 2022
PAGE MF-15
L7044GSI-EPA TURBOCHARGED AND INTERCOOLED GAS ENGINE FOR MOBILE APPLICATIONS, EPA CERT
(Tier 2 Certified Per 40 CFR 1048)
9.375 Inch (238 mm) Bore x 8.5 Inch (216 mm) Stroke – 12 Cylinders, 7041 Cubic Inch (115.4 Liter) Displacement
STANDARD EQUIPMENT
AIR CLEANER – Two, 3″ dry type filter with hinged rain shield and wiring to customer’s control panel. All components shipped loose.
service indicator. EXHAUST OUTLET – Single vertical at rear. Flexible stainless steel
AIR FUEL RATIO CONTROL (AFR) – 2nd generation AFR2 integrates connection with 8” (203 mm) pipe flange.
with ESM for enhanced rich-burn engine control. Utilizes fuel control EXHAUST THERMOCOUPLES – (14) K–type. One for each cylinder
valve between regulator and carburetor and enhanced pre-catalyst exhaust. Includes pre-turbine exhaust thermocouples.
O2 sensor optimized for gaseous fuels for more stable operation FLYWHEEL – Approx. WR2 = 155000 lb-in2; with ring gear (208 teeth),
through fuel swings. Standard AFR2 control system meets machined for 24”, SAE #24 generator coupling, 28.88” (734 mm)
Canadian Standards Association Class 1, Division 2, Group A, B, pilot bore, 27.25” (692 mm) bolt circle, (12) 0.75” – 10 tapped holes.
C, & D (Canada & US) hazardous location requirements. Includes FLYWHEEL HOUSING – No. 00 SAE.
wide-band oxygen sensor. FUEL SYSTEM – Single 3″ ANSI flange fuel inlet connection. Two
BARRING DEVICE – Manual. natural gas, 4″ (102 mm) updraft carburetors and two mounted
BATTERY BOX – Ship loose battery box designed to accommodate Fisher 99, 2” (51 mm) gas regulators. 30 – 60 psi fuel inlet pressure
two Series 31 12 VDC batteries. Includes power disconnect switch required. 10 foot (3 m) harness provided for ESM* control of
and 20 foot (6.1 m) cable for connection to ESM* Power Distribution customer supplied fuel shutoff valve. Fuel control valve located
Box. between regulator and carburetor replaces stepper motor.
BEARINGS – Heavy duty, replaceable, precision type. Wire the customer-supplied fuel
BREATHER – Self-regulating, closed system. Connects to both gas shutoff valve to be controlled
banks. by ESM. If the fuel valve is
CONNECTING RODS – Drop forged steel, rifle drilled. controlled independently of ESM, fault codes will occur when the
CONTROL SYSTEM – Waukesha Engine System Manager (ESM*) fuel valve is not actuated in sequence with the ESM.
integrates spark timing control, speed governing, start-stop control, FRONT STUB SHAFT – 3.5" (89 mm) diameter x 11.75" (292 mm) long,
diagnostic tools, fault logging and engine safeties. Engine Control standard keyway 7/8" (22 mm) x 7/16" (11 mm) x 8" (203 mm) keyway.
Unit (ECU) is central brain of the control system and main customer Allows for customer supplied pulley sizes down to 8" (203 mm) pitch
interface. Interface with ESM is through a 14 ft (4.3m) harness to diameter to customize fan drive speed. Not compatible with Code 1140A
local panel, through MODBUS RTU slave connection RS-485 or 1140B.
multidrop hardware, and through the Electronic Service Program GOVERNOR – Electric throttle actuator controlled by ESM with
(ESP). Customer connections are only required to the local panel, throttle position feedback. Governor tuning is performed using ESP.
fuel valve, and 24V DC power supply. ESM meets Canadian ESM includes option of a load-coming feature to improve engine
Standards Association Class I, Division 2, Group A, B, C, & D response to step loads.
(Canada & US) hazardous location requirements. IGNITION SYSTEM – Ignition Power Module (IPM) controlled by
CRANKCASE – Integral crankcase and cylinder frame. Main bearing ESM, with spark timing. Dual voltage energy levels automatically
caps drilled and tapped for temperature sensors. Does not include controlled by ESM to maximize spark plug life. Shielded ignition
sensors. components that meet Canadian Standard Association Class 1,
CRANKSHAFT – Forged steel, seven main bearings, Division 2, Group A, B, C, & D (Canada & US) hazardous location
counterweighted and dynamically balanced. requirements.
CYLINDERS – Removable wet type cylinder liners. INTERCOOLER – Air-to-water.
CYLINDER HEADS – Twelve interchangeable. Four valves per LEVELING BOLTS
cylinder, with water cooled exhaust valve seats. Roller valve lifters LIFTING EYES – Requires 9.5 ton Working Load Limit (W.L.L.) anchor
and hydraulic push rods. Flange mounted ignition coils. shackles.
ELECTRONIC SERVICE PROGRAM (ESP) – Microsoft Windows- LUBRICATION – Full pressure, gear type pump. Engine mounted full
based program provided on CD-ROM for programming and flow lube oil micro-fiberglass filters with mounted differential
interface to ESM. Includes E-Help for troubleshooting any ESM pressure gauge. MICROSPIN™ bypass filter, engine mounted.
faults. Serial harness is provided for connection of a customer Air/gas motor driven prelube pump, requires final piping.
supplied laptop to the ECU RS-232 port. MAIN BEARING TEMPERATURE SENSORS – Electric (7, type K
ENGINE MONITORING DEVICES – Factory mounted and wired thermocouples)
sensors for lube oil pressure and temperature, intake manifold MANIFOLDS – Exhaust, (2) water cooled.
temperature and pressure, and jacket water temperature, all OIL COOLER – Shell and tube type, with thermostatic temperature
accessible through ESM*. Dual magnetic pick-ups are used for controller and pressure regulating valve. Factory mounted.
accurate engine speed monitoring. ESM provides predictive spark OIL PAN – Deep sump type. 190 gallon (719 L) capacity, including
plug diagnostics as well as advanced diagnostics of engine and all filter and cooler.
ESM sensors and logs any faults into non-volatile flash memory. PAINT – Oilfield orange primer.
Sensors meet Canadian Standards Association Class 1, Division 2, PISTONS – Aluminum with floating pin. Oil cooled. 8:1 compression
Group A, B, C, & D (Canada & US) hazardous location ratio. Optimized for drill rig application.
requirements. SHIPPING SKID – For domestic truck or rail.
ENGINE ROTATION – Counterclockwise when facing flywheel. STARTER – High pressure, air or gas TDI T109, inertia engaged,
EGC8000 I/O Box – Junction box measuring 48” tall x 24” wide x mounted with strainer and valve. Minimum supply pressure 90 psi.
10.8” deep. Provides local display for ESM engine parameters as Maximum supply pressure 150 psi.
well as exhaust and main bearing thermocouples. Also includes
Malfunction Indicator Light (MIL). Includes harnesses for wiring
the I/O Box within 15 feet of the engine harness bulkhead
connection. 50 foot customer interface harnesses included for
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. July 2022
PAGE MF-16
L7044GSI-EPA TURBOCHARGED AND INTERCOOLED GAS ENGINE FOR MOBILE APPLICATIONS, EPA
CERTIFIED
(Tier 2 Certified Per 40 CFR 1048)
(Continued)
THREE WAY CATALYST (TWC) - The Waukesha converter is a dual WATER CIRCULATING SYSTEM, ENGINE JACKET – Belt driven
element design for use with Waukesha gas engines. Its removable water circulating pump. Cluster type thermostatic temperature
cover allows easy access for maintenance and catalyst element regulating valve, full flow bypass type with 165° - 170° F (74° - 77°C)
replacement. 16” inlet and outlet flange. Overall flange-to-flange start to open thermostats. Inlet water header connection includes
length is 62”. Housing can be oriented so element access door is single side-inlet water pump header with 6” (152 mm) flange
removed vertically (12 o'clock) or horizontally (3 or 9 o'clock). Wiring connection. Outlet water connection includes single 6” (152 mm)
harness must be mounted at either 3 or 9 o'clock. Housing must be outlet connection for a 6” (152 mm) Dresser coupling, including
mounted horizontally. coupling.
TURBOCHARGERS – (2) with water-cooled bearing housing and
differential wastegates.
VIBRATION DAMPER – Viscous type.
WATER CIRCULATING SYSTEM, AUXILIARY CIRCUIT – Belt driven
water circulating high capacity pump for intercooler and lube oil
cooler. See S6543-36 performance curve for use with standard 10″
diameter crankshaft pulley. Auxiliary water circuit thermostatic valve for
130° F (54° intercooler water temperature.
Standard on
5794GSI/7044GSI EPA Mobile Certified Spec
Flywheel -- Machined for 24”, SAE #24 generator coupling,
1164 28.88” (734 mm) pilot bore, 27.25” (692 mm) bolt circle,
(12) 0.75” – 10 tapped holes.
Code ACCESSORIES
FUEL SYSTEM
2080 Solenoid Valve 2” NPT, 24V DC. Shipped loose. ...................................................................................................................
AIR CLEANERS
NOTE: Precleaners are recommended for applications in dusty environments or when dust conditions are
unpredictable.
2320B Precleaner – Heavy duty inertia separator, for standard air cleaner. .....................................................................................
ELECTRICAL
3051A Voltage regulator, shipped loose. K65-12B ............................................................................................................................
3051B Voltage regulator, shipped loose. K125-10B ...........................................................................................................................
3433E Alternator – Denso, 24V DC, 50A, Brushless, belt driven direct off crankshaft. Includes engine mounted junction box for
connection to battery. Alternator system meets Canadian Standard Association Class I, Division 2, Group A, B, C & D
(Canada & US) hazardous location requirements. .................................................................................................................
3441 Delete Standard ESM battery box and cable. Customer is responsible for proper sizing of wire from battery to ESM Power
Distribution Box. .....................................................................................................................................................................
COOLING
4282A Preheater – Water jacket heating. 2x4500 watt ......................................................................................................................
4292 Header – Inlet water, and connections. Includes single center-inlet water pump header with 6” (152 mm) flange
connection, (2) inlet elbows, and (2) 4” (102 mm) Dresser couplings.................................................................................
4341 Connections – Water outlet. Single 6” (152 mm) flange, for remote cooling .........................................................................
LUBRICATION
5022 Regulator – Lubricating oil level. Kenco model LCE with explosion-proof electric low level SPDT safety switch and Fire
Safe features. Meets CSA Class I, Division 2, Group B, C, & D requirements. For oil supply with up to 15ft. of static
head. Mounted in place of standard crankcase inspection door .........................................................................................
5229B Lubricating System – Electric prelube pump for prelube and post lube for automatic or remote start applications that have
time to prelube prior to starting engine. Does not include relief valve which is required for continuous operation. Includes
115V AC, 60 HZ, single phase motor driven prelube pump, and motor starter. Omits standard air/gas prelube motor
drive system. .........................................................................................................................................................................
5229D Lubricating System – Electric prelube pump for prelube and post lube for automatic or remote start applications that have
time to prelube prior to starting engine. Does not include relief valve which is required for continuous operation. Includes
208-230V AC, 50/60Hz, single phase motor driven prelube pump, and motor starter. Omits standard air/gas prelube
motor drive system. ...............................................................................................................................................................
5229E Lubricating System – Electric prelube pump for prelube and post lube for automatic or remote start applications that have
time to prelube prior to starting engine. Does not include relief valve which is required for continuous operation. Includes
24V DC motor driven pre-lube pump, motor starter and pressure switch. Omits standard air/gas prelube motor drive
system. Pneumatic control panel will include manual start push button .............................................................................
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. July 2022
PAGE MF-18
Code ACCESSORIES
CONTROLS
6012 Valve – BICERA crankcase explosion relief. Four (4) required ..............................................................................................
6018 Load Sharing dongle for multiple units in island operation (Requires 6665)..........................................................................
6106E Engine Vibration Sensor with 4-20mA output. Includes mounting and shipped-loose harness for connection to I/O box...
6190F Magnetic Pickup – Mounted. Meets Canadian Standards Association Class 1, Division 2, Group A, B, C, & D hazardous
location requirements ............................................................................................................................................................
6302A Battery Charger, 20 amp – Shipped Loose. Static, float/equalize type with DC ammeter and DC voltmeter. 230V AC, 1
ph 50/60 Hz input, 24V DC output. For lead–acid batteries only. Supplied in a NEMA enclosure for separate remote
mounting. ...............................................................................................................................................................................
6665 Genset Control, Includes NEMA 12 Enclosure for EGC8000 Engine - Generator Control Package. For run / stop control,
synchronizing and load sharing (with code 6018). Also adds E-Stop Switch, Warning and Shutdown Lights, Alarm
Horn, and K65-12B voltage regulator. (Not for use with code 3051A or 3051B, as already included) ..............................
6667 Customer Interface Harness – 100 ft (30 m) EGC8000 Control harness between I/O Box and control panel (either
customer control panel or EGC8000 control panel), replaces 50 ft (15 m) harness. .........................................................
6669 25ft (7.6m) Engine/Genset Control Harnesses between I/O Box and Engine Bulkhead (Group of 7 Harnesses) for remote
mount of I/O Box. Replaces standard 14ft (4.3m) group of harnesses. Reference EPA Manual page 2.05-21 for
instructions on unobstructed view of I/O Box MIL ................................................................................................................
MISCELLANEOUS
9974X Required Label for Hazardous Location CSA Certification in US & Canada End Use. Adds a safety label containing
English and French language that is required to comply with the certification terms of the equipment. Note: For end
uses classified as Hazardous Locations Division 2 and in US & Canada. Contact Application Engineering for use in
other countries.......................................................................................................................................................................
9990 Waukesha standard paint quality to match customer supplied paint chip. Requires FED-STD-595B or 595C ...................
9998A Shipping Skid – For overseas container ..................................................................................................................................
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. July 2022
PAGE MF-19
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. July 2022
PAGE MF-20
VHP7104GSI-EPA TURBOCHARGED AND INTERCOOLED GAS GENSET FOR MOBILE APPLICATIONS, EPA
CERTIFIED
(Tier 2 Certified Per 40 CFR 1048)
(Continued)
PAINT – Oilfield orange primer. WATER CIRCULATING SYSTEM, AUXILIARY CIRCUIT – Belt driven
PISTONS – Aluminum with floating pin. Oil cooled. 8:1 compression water circulating highcapacity pump for intercooler and lube oil
ratio. Optimized for drill rig application. cooler. See S6543-36 performance curve for use with standard 10″
STARTER – High pressure, air or gas TDI T109, inertia engaged, diameter crankshaft pulley. Auxiliary water circuit thermostatic valve for
mounted with strainer and valve. Minimum supply pressure 90 psi. 130° F (54° intercooler water temperature.
Maximum supply pressure 150 psi. WATER CIRCULATING SYSTEM, ENGINE JACKET – Belt driven
THREE WAY CATALYST (TWC) - The Waukesha converter is a dual water circulating pump. Cluster type thermostatic temperature
element design for use with Waukesha gas engines. Its removable regulating valve, full flow bypass type with 165° - 170° F (74° - 77°C)
cover allows easy access for maintenance and catalyst element start to open thermostats. Inlet water header connection includes
replacement. 16” inlet and outlet flange. Overall flange-to-flange single side-inlet water pump header with 6” (152 mm) flange
length is 62”. Housing can be oriented so element access door is connection. Outlet water connection includes single 6” (152 mm)
removed vertically (12 o'clock) or horizontally (3 or 9 o'clock). Wiring outlet connection for a 6” (152 mm) Dresser coupling, including
harness must be mounted at either 3 or 9 o'clock. Housing must be coupling.
mounted horizontally.
TURBOCHARGERS – (2) with water-cooled bearing housing and
differential wastegates.
VIBRATION DAMPER – Viscous type.
Standard on
VHP7104GSI EPA Mobile Certified Spec
4293 Inlet Water Header; Side Inlet
FUEL SYSTEM
2080 Solenoid Valve 2” NPT, 24V DC. Shipped loose. ....................................................................................................................
AIR CLEANERS
NOTE: Precleaners are recommended for applications in dusty environments or when dust conditions are unpredictable.
2320B Precleaner – Heavy duty inertia separator, for standard air cleaner.......................................................................................
ELECTRICAL
3051B Voltage regulator, shipped loose. K125-10B ............................................................................................................................
3433E Alternator – Denso, 24V DC, 50A, Brushless, belt driven direct off crankshaft. Includes engine mounted junction box for
connection to battery. Alternator system meets Canadian Standard Association Class I, Division 2, Group A, B, C & D
(Canada & US) hazardous location requirements. .................................................................................................................
3441 Delete Standard ESM battery box and cable. Customer is responsible for proper sizing of wire from battery to ESM Power
Distribution Box.......................................................................................................................................................................
COOLING
4282A Preheater – Water jacket heating. 2x4500 watt .......................................................................................................................
4292 Header – Inlet water, and connections. Includes single center-inlet water pump header with 6” (152 mm) flange
connection, (2) inlet elbows, and (2) 4” (102 mm) Dresser couplings .................................................................................
4341 Connections – Water outlet. Single 6” (152 mm) flange, for remote cooling ..........................................................................
LUBRICATION
5022 Regulator – Lubricating oil level. Kenco model LCE with explosion-proof electric low level SPDT safety switch and Fire
Safe features. Meets CSA Class I, Division 2, Group B, C, & D requirements. For oil supply with up to 15ft. of static
head. Mounted in place of standard crankcase inspection door ..........................................................................................
5229B Lubricating System – Electric prelube pump for prelube and post lube for automatic or remote start applications that have
time to prelube prior to starting engine. Does not include relief valve which is required for continuous operation. Includes
115V AC, 60 HZ, single phase motor driven prelube pump, and motor starter. Omits standard air/gas prelube motor
drive system. ..........................................................................................................................................................................
5229D Lubricating System – Electric prelube pump for prelube and post lube for automatic or remote start applications that have
time to prelube prior to starting engine. Does not include relief valve which is required for continuous operation. Includes
208-230V AC, 50/60Hz, single phase motor driven prelube pump, and motor starter. Omits standard air/gas prelube
motor drive system. ...............................................................................................................................................................
5229E Lubricating System – Electric prelube pump for prelube and post lube for automatic or remote start applications that have
time to prelube prior to starting engine. Does not include relief valve which is required for continuous operation. Includes
24V DC motor driven pre-lube pump, motor starter and pressure switch. Omits standard air/gas prelube motor drive
system. Pneumatic control panel will include manual start push button .............................................................................
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. July 2022
PAGE MF-22
CONTROLS
6012 Valve – BICERA crankcase explosion relief. Four (4) required ...............................................................................................
6018 Load Sharing dongle for multiple units in island operation (Requires 6665) ..........................................................................
6106E Engine Vibration Sensor with 4-20mA output. Includes mounting and shipped-loose harness for connection to I/O box ...
6190F Magnetic Pickup – Mounted. Meets Canadian Standards Association Class 1, Division 2, Group A, B, C, & D hazardous
location requirements ............................................................................................................................................................
6302A Battery Charger, 20 amp – Shipped Loose. Static, float/equalize type with DC ammeter and DC voltmeter. 230V AC, 1
ph 50/60 Hz input, 24V DC output. For lead–acid batteries only. Supplied in a NEMA enclosure for separate remote
mounting.................................................................................................................................................................................
6665 Genset Control, Includes NEMA 12 Enclosure for EGC8000 Engine - Generator Control Package. For run / stop control,
synchronizing and load sharing (with code 6018). Also adds E-Stop Switch, Warning and Shutdown Lights, Alarm
Horn, and K65-12B voltage regulator. (Not for use with code 3051A or 3051B, as already included) ..............................
6667 Customer Interface Harness – 100 ft (30 m) EGC8000 Control harness between I/O Box and control panel (either
customer control panel or EGC8000 control panel), replaces 50 ft (15 m) harness. ..........................................................
6669 25ft (7.6m) Engine/Genset Control Harnesses between I/O Box and Engine Bulkhead (Group of 7 Harnesses) for remote
mount of I/O Box. Replaces standard 14ft (4.3m) group of harnesses. Reference EPA Manual page 2.05-21 for
instructions on unobstructed view of I/O Box MIL ................................................................................................................
MISCELLANEOUS
9974X Required Label for Hazardous Location CSA Certification in US & Canada End Use. Adds a safety label containing
English and French language that is required to comply with the certification terms of the equipment. Note: For end
uses classified as Hazardous Locations Division 2 and in US & Canada. Contact Application Engineering for use in
other countries. .....................................................................................................................................................................
9990 Waukesha standard paint quality to match customer supplied paint chip. Requires FED-STD-595B or 595C ...................
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. July 2022
PAGE MF-23
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. July 2022
PAGE MF-24
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. July 2022
PAGE MF-25
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. July 2022
PAGE MF-26
Standard on
5794GSI/7044GSI MOB Spec Engines
Flywheel -- Machined for 24”, SAE #24 generator coupling,
1164 28.88” (734 mm) pilot bore, 27.25” (692 mm) bolt circle,
(12) 0.75” – 10 tapped holes
Code ACCESSORIES
FUEL SYSTEM
2080 Solenoid Valve 2” NPT, 24V DC. Shipped loose. ...................................................................................................................
AIR CLEANERS
NOTE: Precleaners are recommended for applications in dusty environments or when dust conditions are
unpredictable.
2320B Precleaner – Heavy duty inertia separator, for standard air cleaner.. ....................................................................................
ELECTRICAL
3051A Voltage regulator, shipped loose. K65-12B ............................................................................................................................
3051B Voltage regulator, shipped loose. K125-10B ...........................................................................................................................
3433E Alternator – Denso, 24V DC, 50A, Brushless, belt driven direct off crankshaft. Includes engine mounted junction box for
connection to battery. Alternator system meets Canadian Standard Association Class I, Division 2, Group A, B, C & D
(Canada & US) hazardous location requirements. .................................................................................................................
3441 Delete Standard ESM battery box and cable. Customer is responsible for proper sizing of wire from battery to ESM Power
Distribution Box. .....................................................................................................................................................................
COOLING
4282A Preheater – Water jacket heating. 2x4500 watt ......................................................................................................................
4292 Header – Inlet water, and connections. Includes single center-inlet water pump header with 6” (152 mm) flange
connection, (2) inlet elbows, and (2) 4” (102 mm) Dresser couplings.................................................................................
4341 Connections – Water outlet. Single 6” (152 mm) flange, for remote cooling .........................................................................
LUBRICATION
5022 Regulator – Lubricating oil level. Kenco model LCE with explosion-proof electric low level SPDT safety switch and Fire
Safe features. Meets CSA Class I, Division 2, Group B, C, & D requirements. For oil supply with up to 15ft. of static
head. Mounted in place of standard crankcase inspection door .........................................................................................
5229B Lubricating System – Electric prelube pump for prelube and post lube for automatic or remote start applications that have
time to prelube prior to starting engine. Does not include relief valve which is required for continuous operation. Includes
115V AC, 60 HZ, single phase motor driven prelube pump, and motor starter. Omits standard air/gas prelube motor
drive system. .........................................................................................................................................................................
5229D Lubricating System – Electric prelube pump for prelube and post lube for automatic or remote start applications that have
time to prelube prior to starting engine. Does not include relief valve which is required for continuous operation. Includes
208-230V AC, 50/60Hz, single phase motor driven prelube pump, and motor starter. Omits standard air/gas prelube
motor drive system. ...............................................................................................................................................................
5229E Lubricating System – Electric prelube pump for prelube and post lube for automatic or remote start applications that have
time to prelube prior to starting engine. Does not include relief valve which is required for continuous operation. Includes
24V DC motor driven pre-lube pump, motor starter and pressure switch. Omits standard air/gas prelube motor drive
system. Pneumatic control panel will include manual start push button .............................................................................
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. July 2022
PAGE MF-28
Code ACCESSORIES
CONTROLS
6012 Valve – BICERA crankcase explosion relief. Four (4) required
6018 Load Sharing dongle for multiple units in island operation (Requires 6665)
6106E Engine Vibration Sensor with 4-20mA output. Includes mounting and shipped-loose harness for connection to I/O
box…
6190F Magnetic Pickup – Mounted. Meets Canadian Standards Association Class 1, Division 2, Group A, B, C, & D
hazardous location requirements
6302A Battery Charger, 20 amp – Shipped Loose. Static, float/equalize type with DC ammeter and DC voltmeter. 230V AC, 1
ph 50/60 Hz input, 24V DC output. For lead–acid batteries only. Supplied in a NEMA enclosure for separate remote
mounting.
6665 Genset Control, Includes NEMA 12 Enclosure for EGC8000 Engine - Generator Control Package. For run / stop
control, synchronizing and load sharing (with code 6018). Also adds E-Stop Switch, Warning and Shutdown Lights,
Alarm Horn, and K65-12B voltage regulator. (Not for use with code 3051A or 3051B, as already included)
6667 Customer Interface Harness – 100 ft (30 m) EGC8000 Control harness between I/O Box and control panel (either
customer control panel or EGC8000 control panel), replaces 50 ft (15 m) harness.
6669 25ft (7.6m) Engine/Genset Control Harnesses between I/O Box and Engine Bulkhead (Group of 7 Harnesses) for
remote mount of I/O Box. Replaces standard 14ft (4.3m) group of harnesses. Reference EPA Manual page 2.05-21
for instructions on unobstructed view of I/O Box MIL
MISCELLANEOUS
9974Q Engine/Enginator that is Customs Union Compliant (Russia, Belarus, and Kazakhstan). Includes SERIAL NUMBER
SPECIFIC Technical Passport & Safety Justification in Russian and English, Engine Operator's Manuals (one in
Russian and one in English), and EAC label on unit. Enginators include supplied equipment manuals that are in
English only. May require additional lead time, consult factory for delivery information
9974U Engine that is CE Mark Compliant. Includes a SERIAL NUMBER SPECIFIC Declaration of Incorporation and
Operator's Manual both in English. It is the responsibility of the entity (Packager, Distributor..) placing the complete
package on the European market to ensure that the final complete package (machine) is properly CE Marked and
that the final customer is provided with the required translated manuals. Waukesha can assist with translations at
additional cost, contact Applications/Sales
9974X Required label for Hazardous Location CSA Certification in US & Canada end use. Adds a safety label containing
English and French language that is required to comply with the certification terms of the equipment. Note: For end
uses classified as Hazardous Locations Division 2 and in US & Canada. Contact Application Engineering for use in
other countries.
9990 Waukesha standard paint quality to match customer supplied paint chip. Requires FED-STD-595B or 595C
9998A Shipping Skid – For overseas container
DISCLAIMER
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. July 2022
PAGE MF-29
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. July 2022
PAGE MF-30
Standard on
VHP7104GSI MOB Spec Gas Gensets
4293 Inlet Water Header; Side Inlet
FUEL SYSTEM
2080 Solenoid Valve 2” NPT, 24V DC. Shipped loose. ....................................................................................................................
AIR CLEANERS
NOTE: Precleaners are recommended for applications in dusty environments or when dust conditions are unpredictable.
2320B Precleaner – Heavy duty inertia separator, for standard air cleaner.......................................................................................
ELECTRICAL
3051B Voltage regulator, shipped loose. K125-10B ............................................................................................................................
3433E Alternator – Denso, 24V DC, 50A, Brushless, belt driven direct off crankshaft. Includes engine mounted junction box for
connection to battery. Alternator system meets Canadian Standard Association Class I, Division 2, Group A, B, C & D
(Canada & US) hazardous location requirements. .................................................................................................................
3441 Delete Standard ESM battery box and cable. Customer is responsible for proper sizing of wire from battery to ESM Power
Distribution Box.......................................................................................................................................................................
COOLING
4282A Preheater – Water jacket heating. 2x4500 watt .......................................................................................................................
4292 Header – Inlet water, and connections. Includes single center-inlet water pump header with 6” (152 mm) flange
connection, (2) inlet elbows, and (2) 4” (102 mm) Dresser couplings .................................................................................
4341 Connections – Water outlet. Single 6” (152 mm) flange, for remote cooling ..........................................................................
LUBRICATION
5022 Regulator – Lubricating oil level. Kenco model LCE with explosion-proof electric low level SPDT safety switch and Fire
Safe features. Meets CSA Class I, Division 2, Group B, C, & D requirements. For oil supply with up to 15ft. of static
head. Mounted in place of standard crankcase inspection door ..........................................................................................
5229B Lubricating System – Electric prelube pump for prelube and post lube for automatic or remote start applications that have
time to prelube prior to starting engine. Does not include relief valve which is required for continuous operation. Includes
115V AC, 60 HZ, single phase motor driven prelube pump, and motor starter. Omits standard air/gas prelube motor
drive system. ..........................................................................................................................................................................
5229D Lubricating System – Electric prelube pump for prelube and post lube for automatic or remote start applications that have
time to prelube prior to starting engine. Does not include relief valve which is required for continuous operation. Includes
208-230V AC, 50/60Hz, single phase motor driven prelube pump, and motor starter. Omits standard air/gas prelube
motor drive system. ...............................................................................................................................................................
5229E Lubricating System – Electric prelube pump for prelube and post lube for automatic or remote start applications that have
time to prelube prior to starting engine. Does not include relief valve which is required for continuous operation. Includes
24V DC motor driven pre-lube pump, motor starter and pressure switch. Omits standard air/gas prelube motor drive
system. Pneumatic control panel will include manual start push button .............................................................................
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. July 2022
PAGE MF-32
CONTROLS
6012 Valve – BICERA crankcase explosion relief. Four (4) required ...............................................................................................
6018 Load Sharing dongle for multiple units in island operation (Requires 6665) ..........................................................................
6106E Engine Vibration Sensor with 4-20mA output. Includes mounting and shipped-loose harness for connection to I/O box ...
6190F Magnetic Pickup – Mounted. Meets Canadian Standards Association Class 1, Division 2, Group A, B, C, & D
hazardous location requirements ..........................................................................................................................................
6302A Battery Charger, 20 amp – Shipped Loose. Static, float/equalize type with DC ammeter and DC voltmeter. 230V AC, 1
ph 50/60 Hz input, 24V DC output. For lead–acid batteries only. Supplied in a NEMA enclosure for separate remote
mounting.................................................................................................................................................................................
6665 Genset Control, Includes NEMA 12 Enclosure for EGC8000 Engine - Generator Control Package. For run / stop
control, synchronizing and load sharing (with code 6018). Also adds E-Stop Switch, Warning and Shutdown Lights,
Alarm Horn, and K65-12B voltage regulator. (Not for use with code 3051A or 3051B, as already included) ....................
6667 Customer Interface Harness – 100 ft (30 m) EGC8000 Control harness between I/O Box and control panel (either
customer control panel or EGC8000 control panel), replaces 50 ft (15 m) harness. ..........................................................
6669 25ft (7.6m) Engine/Genset Control Harnesses between I/O Box and Engine Bulkhead (Group of 7 Harnesses) for
remote mount of I/O Box. Replaces standard 14ft (4.3m) group of harnesses. Reference EPA Manual page 2.05-21
for instructions on unobstructed view of I/O Box MIL ...........................................................................................................
MISCELLANEOUS
9974Q Engine/Enginator that is Customs Union Compliant (Russia, Belarus, and Kazakhstan). Includes SERIAL NUMBER
SPECIFIC Technical Passport & Safety Justification in Russian and English, Engine Operator's Manuals (one in
Russian and one in English), and EAC label on unit. Enginators include supplied equipment manuals that are in
English only. May require additional lead time, consult factory for delivery information ...................................................
9974V Enginator that is CE Mark Compliant. Includes CE Mark Label, the following documentation in both English and
language of country of final installation, order to state required language; SERIAL NUMBER SPECIFIC Declaration of
Conformance, Operator, Generator and Voltage Regulator Manuals. All other supporting documentation is supplied
in English only. Contact Applications/Sales if the sale requires additional translation requirements. May require
additional lead time and cost, consult factory for delivery information ...............................................................................
9974X Required label for Hazardous Location CSA Certification in US & Canada end use. Adds a safety label containing
English and French language that is required to comply with the certification terms of the equipment. Note: For end
uses classified as Hazardous Locations Division 2 and in US & Canada. Contact Application Engineering for use in
other countries. ...................................................................................................................................................................
9990 Waukesha standard paint quality to match customer supplied paint chip. Requires FED-STD-595B or 595C ...................
DISCLAIMER
COUNTRY-REGION REGULATORY REQUIREMENTS
Waukesha gas engines make every effort to ensure that Waukesha products meet all required regulatory requirements. However, because the
regulatory landscape is changing at an ever increasing rate, some orders will require additional work to meet local requirements. If your region has
special requirements not met by standard Waukesha product/option codes, please contact your Regional Sales Manager.
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. July 2022
PAGE GS 275GL-1
Rating Standard: All models: Ratings conform to ISO 3046/1 (latest version) with a mechanical efficiency of 90% and
auxiliary water temperature, Tcra, as specified in the Power Rating Chart, Bulletin 1079 (latest version) limited to ±10° F
(±5.5° C). Ratings are also valid for SAE J1349, BS 5514, DIN 6271 and API 7B-11C standard atmospheric reference
conditions.
Fuel Standard: All natural gas engine ratings are based on 900 BTU/ft3 (35.38 MJ/m3 [25, V(0; 101.325)]) SLHV, 91 WKI*
minimum, commercial quality natural gas. Refer to S-7884-7 (latest version) for full gaseous fuel specifications.
Generator Continuous Power Rating (kWe): The highest load and speed which can be applied 24 hours per day, seven
days per week, 365 days per year except for normal maintenance. No overload allowed.
Note: List price includes Enginator* control panel model ECP8000E. See Control Panel section for panel options.
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. June 2022
PAGE GS 275GL-2
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. June 2022
PAGE GS 275GL-3
STANDARD EQUIPMENT
AIR INLET AND EXHAUST SYSTEMS ENGINE MONITORING DEVICES - Wired sensors for NOx emissions,
Air Cleaner - Two, dry panel type with mechanical gauge for remote lube oil pressure and temperature, intake manifold temperature and
mounting (shipped loose). pressure, overspeed; jacket and auxiliary water temperature; all
Air Inlet Connection – Two horizontal inlet flanges accessible through ESM2 interface. Sensors meet Canadian Standards
Exhaust Manifold – Dry with protective insulation. Association Class 1, Division 2, Group A, B, C, & D (Canada & US)
Exhaust Outlet – Two horizontal outlet flanges. hazardous location requirements. ESM2 continually monitors combustion
BARRING DEVICE – Manual. performance through accelerometers to provide detonation protection.
BASE – Engine and generator are mounted and aligned on a structural Magnetic pick-ups are used for accurate engine speed monitoring. ESM2
steel fabricated base with lifting outriggers. Suitable for solid or spring provides predictive spark plug diagnostics as well as advanced
isolator mounting on a proper foundation. diagnostics of engine and all ESM2 sensors and logs any faults into non-
volatile flash memory. K-type thermocouples for individual cylinder
CAMSHAFT – Consists of individual segments, one per cylinder, bolted
exhaust temperatures and turbocharger temperatures are wired to ESM2.
together.
Main bearing temperature sensors – Type K sensors are wired to ESM2
CONNECTING RODS – Low alloy, forged, fully machined.
ENGINE PROTECTION DEVICES – Engine emergency
CONTROL SYSTEM – Waukesha Engine System Manager 2 (ESM2*) shutdown/starter lockout palm button (2) mounted, one wired on either
integrates spark timing control, speed governing, detonation protection, side of the engine. Engine protection is also provided by ESM for: lube
misfire detection, start-stop control, diagnostic information, fault logging, oil pressure and temperature, intake manifold temperature and
engine safeties and (Air/Fuel Ratio) control in one Engine Control Unit pressure, overspeed, and jacket water temperature.
(ECU). One customer connection to the control system via a 50-foot ENGINE ROTATION - Counterclockwise when facing flywheel.
Customer Interface harness (15.2 m). ESM2 also provides a MODBUS FLYWHEEL – Mounted, with 291 tooth ring gear. Machined for generator
RTU slave RS-485 connection for integration into local panels. Customer coupling.
connections are required to the local panel, fuel valve, and 24V DC power
supply. Compatible with Woodward load sharing module. ESM2 meets FLYWHEEL GUARD – Fabricated steel guard for protection of the rotating
Canadian Standards Association Class I, Division 2, Group A, B, C, & D components is mounted to the engine–generator base.
(Canada & US) hazardous location requirements. Includes 12” ESM2 FUEL SYSTEM – Carburetor with precombustion circuit. Single fuel inlet
Display Panel connection, mounted main and prechamber gas supply regulators and
CONTROL PANEL – ECP8000 Genset Control System consisting of: 24V DC pilot operated prechamber fuel valve. Engine-mounted 24V
• An engine-mounted panel (NEMA 4, IP 65) containing a ComAp DC pilot operated main fuel valve.
InteliSys-NTC controller, analog and discrete I/O modules GENERATOR – Open drip-proof, direct connected, fan cooled, 2/3 pitch,
harnessed to genset sensors and the ESM2 control system. A.C. revolving field type, oil lubricated sleeve bearings, with brushless
• ESM2 Display Panel is mounted in the panel along with the PMG type exciter and damper windings. TIF and deviation factor within
voltage regulator, and other control devices. NEMA MG-1.32. Voltage: 4160 V or 13,800 V, 3 phase, 6 wire WYE, 60
• Customer supplied transformers to be wired to the ECP8000 Hz, and 3300 V, 6300 V or 11000 V 3 phase, 6-wire, WYE, 50 Hz.
panel using the 100ft shipped loose AC Sensing harness. Insulation material NEMA Class F. Temperature rise within NEMA (105°
For further details, see the Engomatic Control Systems section. C) for continuous power duty. All generators are rated at 0.8 power
CRANKCASE – Single piece, stress relieved, gray iron casting. Main factor. Includes space heater,
bearing caps are retained with vertical studs and lateral tie bolts. 230 V, 1 phase, winding and bearing RTDs, and a ECP8000 mounted
CRANKCASE PRESSURE RELIEF DOORS – Seven mounted on side automatic voltage regulator. The regulator is a three phase sensing
of crankcase. type and has a regulation accuracy of 0.5%. 460V 3ph 60Hz or
CRANKCASE VENTILATION SYSTEM – Forced ventilation with CSA 380VAC 3ph 50Hz generator bearing circulation pump.
Class I Groups C&D Class II Groups F&G 230V AC/1 ph blower, NOTE: Generator is removed after testing and is shipped loose.
restriction valve, and check valve. 4” blower outlet for customer GOVERNOR – Electric throttle actuator controlled by ESM2 with throttle
connection per local codes. Motor starter must be relocated to a Safe position feedback. Governor tuning is performed provided HMI..
Area to meet CSA Class I Groups C&D Class II Groups F&G IGNITION SYSTEM – Ignition Power Module (IPMD2) controlled by
applications. Optional 115V AC/1 ph electric motor. ESM2, with spark timing optimized for any speed-load condition. Dual
CRANKSHAFT – Low alloy, forged, fully machined, counterweighted voltage energy levels automatically controlled by ESM2 to maximize
with seven main bearing journals. Bearings are heavy duty, spark plug life. Shielded ignition components meet Canadian Standard
replaceable, precision aluminum type. Association Class 1, Division 2, Group A, B, C & D (Canada & US)
CYLINDER HEAD – Twelve interchangeable, bore–cooled with two hazardous location requirements.
hard faced intake and two hard faced exhaust valves per head. INTERCOOLER – Air–to–water.
Includes stainless steel intake and exhaust valve seats and JUNCTION BOXES – Junction boxes for Enginator wiring and external
prechamber fuel control valves. No head gaskets are required. connections.
CYLINDER LINER – Removable wet type with intermediate jacket water
guide.
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. June 2022
PAGE GS 275GL-4
STANDARD EQUIPMENT
LUBRICATION SYSTEM – Gear driven, externally mounted gear type Auxiliary Circuit – Includes mounted auxiliary water temperature
pump with pressure regulator and bypass circuit. Fully mounted and control valve with mounted bypass, gear driven water pump,
integrated plate type oil cooler and full flow lube oil filters. Includes mounted intercooler, and mounted oil cooler. Provides single
centrifugal oil bypass filtration for maximum oil and filter life. customer inlet and single customer outlet connection.
Intercooler and lube oil cooler plumbed in series. Includes electric Engine Jacket – Includes mounted 180°F (82°C) jacket water
motor driven pre/post lube pump. 230VAC 1ph 50/60Hz prelube pump. temperature control valve with mounted bypass and gear driven
115VAC 1ph 50/60hz available as a no code. water pump. Provides single customer inlet and single customer
PAINT – Oilfield orange topcoat. outlet connection.
PISTON – Single piece, aluminum alloy with integrally cast cooling DOCUMENTATION
passages. Four piston rings with the top two compression rings The following items are supplied as standard with every order.
housed in a Ni–resist ring carrier. – Electronic notification and access to drawings for review and or
STARTING SYSTEM – Two TDI 112 turbine pneumatic starters with approval.
24VDC starting valve and strainer. Requires 150 psig (10.3 bar) – One Enginator* manual consisting of:
air/gas supply.
• Engine operation/service manual.
TURBOCHARGER – Two, exhaust driven. Wastegate and compressor
• Engine parts book.
bypass actuators controlled by ESM2.
• Generator/voltage regulator instructions.
VIBRATION DAMPER – Enclosed, hydrolastic type.
WATER CIRCULATION SYSTEM • Instructions on major special items.
FOR DESCRIPTIONS AND DETAILS OF CONTROL PANEL AND SWITCHGEAR OFFERINGS PLEASE REFER TO CONTROL PANELS &
SWITCHGEAR SECTION
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. June 2022
PAGE GS 275GL-5
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. June 2022
PAGE GS 275GL-6
STANDARD EQUIPMENT
PAINT – Oilfield orange topcoat. Engine Jacket – Includes mounted 180°F (82°C) jacket water
PISTON – Single piece, aluminum alloy with integrally cast cooling temperature control valve with mounted bypass and gear driven water
passages. Four piston rings with the top two compression rings housed in pump. Provides single customer inlet and single customer outlet
a Ni–resist ring carrier. connection.
STARTING SYSTEM – Two TDI 112 turbine pneumatic starters with 24VDC DOCUMENTATION
starting valve and strainer. Requires 150 psig (10.3 bar) air/gas supply. The following items are supplied as standard with every order.
TURBOCHARGER – Two, exhaust driven. Wastegate and compressor
– Electronic notification and access to drawings for review and or
bypass actuators controlled by ESM2.
approval.
VIBRATION DAMPER – Enclosed, hydroelastic type.
– One Enginator* manual consisting of:
WATER CIRCULATION SYSTEM
• Engine operation/service manual.
Auxiliary Circuit – Includes mounted auxiliary water temperature control
• Engine parts book.
valve with mounted bypass, gear driven water pump, mounted
intercooler, and mounted oil cooler. Provides single customer inlet and • Generator/voltage regulator instructions.
single customer outlet connection. • Instructions on major special items.
FOR DESCRIPTIONS AND DETAILS OF CONTROL PANEL AND SWITCHGEAR OFFERINGS PLEASE REFER TO CONTROL PANELS &
SWITCHGEAR SECTION
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. June 2022
PAGE GS 275GL-7
LUBRICATION
5040A X X X X Air Driven Pre-Lube Pump – Engine mounted, air/gas motor-driven prelube pump. Pump motor: frame size
182C, Rated 4.15HP @ 3000 rpm, air consumption at maximum HP 181 SCFM Color-machinery gray.
Replaces standard electric prelube motor. .........................................................................................................
5200C X X X X Lubrication Oil Level Regulator ............................................................................................................................
EXHAUST/FLEX SYSTEM
7200A X Combination Exhaust Transition and Flex Connection, 8″ (203 mm) ANSI flange to 14″ (356 mm) ANSI flange
(Includes 2, 1 per bank), shipped loose. Suitable for rigidly mounted units only. Not for use with vibration
isolators..............................................................................................................................................................
7200B X X X Exhaust Flexes, 14″ (356 mm) ANSI flanges x 13″ (330 mm) long. (Includes 2, 1 per bank), shipped loose.
Suitable for rigidly mounted units only. Not for use with vibration isolators. ...................................................
7201B X X X Exhaust Y – Transition. Two 14″ (356 mm) ANSI flanges to a single 28″ (710 mm) ANSI flange. Includes
code 7200B. Shipped Loose .............................................................................................................................
7201C X Exhaust Y – Transition, Two 14” (356 mm) ANSI flanges to a single 22″ (559 mm) ANSI flanged outlet.
Includes code 7200A. Shipped loose. ............................................................................................................. .
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. June 2022
PAGE GS 275GL-8
STARTING SYSTEM
9200B X X X X Pressure Reducing Regulators – Quantity 2 - To provide regulated air pressure to the air start system when
supply air pressure is a maximum of 300 PSIG (20.7 bar) inlet. Outlet pressure is adjustable up to 160 psig
(11 bar). Shipped loose (for use with standard 16V275GL+ air starters or option codes 9209, 9209A, or
9209B) .................................................................................................................................................................
BASES
9510G X X X X Vibration Isolators - Spring type. (For seismic zone applications other than Zone 0, contact Application
Engineering). Shipped loose ..............................................................................................................................
9512 X X X X Jacking Bolts – for leveling unit base in the field. Quantity (12), 6 per side, size 1” (25 mm) diameter by 3.75”
(95 mm) long ......................................................................................................................................................
MISCELLANEOUS
9990 X X X X Waukesha standard paint quality to match customer supplied paint chip. Requires FED-STD-595B or 595C.
9974Q X X X X Engine/Enginator that is Customs Union Compliant (Russia, Belarus, and Kazakhstan). Includes SERIAL
NUMBER SPECIFIC Technical Passport & Safety Justification in Russian and English, Engine
Operator's Manuals (one in Russian and one in English), and EAC label on unit. Enginators include
supplied equipment manuals that are in English only. May require additional lead time, consult factory
for delivery information. ...................................................................................................................................
9974V X X X X Enginator that is CE Mark Compliant. Includes CE Mark Label, the following documentation in both
English and language of country of final installation, order to state required language; SERIAL NUMBER
SPECIFIC Declaration of Conformance, Operator, Generator and Voltage Regulator Manuals. All other
supporting documentation is supplied in English only. Contact Applications/Sales if the sale requires
additional translation requirements. May require additional lead time and cost, consult factory for
delivery information ..........................................................................................................................................
9974X X X X X Required label for Hazardous Location CSA Certification in US & Canada end use. Adds a safety label
containing English and French language that is required to comply with the certification terms of the
equipment. Note: For end uses classified as Hazardous Locations Division 2 and in US & Canada.
Contact Application Engineering for use in other countries. ..........................................................................
EXTENDED WARRANTY
10016AA X X 12V275GL+ Enginator Extended Warranty -- 1 Year. Extended warranty excludes wear items and includes
only warrantable items as defined in Express Limited Warranty (ELW). Must be purchased at time of
original order. If applicable, the proper deferral process and preservation as outlined in Service Bulletin
16-1855H (or most current) and WEDA 542 (or most current) must be followed or warranty extension is
void. ..................................................................................................................................................................
10016BB X X 12V275GL+ Enginator Extended Warranty -- 2 Years. Extended warranty excludes wear items and
includes only warrantable items as defined in Express Limited Warranty (ELW). Must be purchased at
time of original order. If applicable, the proper deferral process and preservation as outlined in Service
Bulletin 16-1855H (or most current) and WEDA 542 (or most current) must be followed or warranty
extension is void.. ............................................................................................................................................
10016CC X X 12V275GL+ Enginator Extended Warranty -- 3 Years. Extended warranty excludes wear items and
includes only warrantable items as defined in Express Limited Warranty (ELW). Must be purchased at
time of original order. If applicable, the proper deferral process and preservation as outlined in Service
Bulletin 16-1855H (or most current) and WEDA 542 (or most current) must be followed or warranty
extension is void. .............................................................................................................................................
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. June 2022
PAGE GS 275GL-9
DISCLAIMER
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. June 2022
PAGE GS VHP-1
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. June 2022
PAGE GS VHP-2
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. June 2022
PAGE GS VHP-3
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. June 2022
PAGE GS VHP-4
FOR DESCRIPTIONS AND DETAILS OF CONTROL PANEL AND SWITCHGEAR OFFERINGS PLEASE REFER TO CONTROL PANELS &
SWITCHGEAR SECTION
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. June 2022
PAGE GS VHP-5
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. June 2022
PAGE GS VHP-6
FOR DESCRIPTIONS AND DETAILS OF CONTROL PANEL AND SWITCHGEAR OFFERINGS PLEASE REFER TO CONTROL PANELS &
SWITCHGEAR SECTION
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. June 2022
PAGE GS VHP-7
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. June 2022
PAGE GS VHP-8
FOR DESCRIPTIONS AND DETAILS OF CONTROL PANEL AND SWITCHGEAR OFFERINGS PLEASE REFER TO CONTROL PANELS &
SWITCHGEAR SECTION
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. June 2022
PAGE GS VHP-9
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. June 2022
PAGE GS VHP-10
FOR DESCRIPTIONS AND DETAILS OF CONTROL PANEL AND SWITCHGEAR OFFERINGS PLEASE REFER TO CONTROL PANELS &
SWITCHGEAR SECTION
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. June 2022
PAGE GS VHP-11
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. June 2022
PAGE GS VHP-12
FOR DESCRIPTIONS AND DETAILS OF CONTROL PANEL AND SWITCHGEAR OFFERINGS PLEASE REFER TO CONTROL PANELS &
SWITCHGEAR SECTION
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. June 2022
PAGE GS VHP-13
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. June 2022
PAGE GS VHP-14
FOR DESCRIPTIONS AND DETAILS OF CONTROL PANEL AND SWITCHGEAR OFFERINGS PLEASE REFER TO CONTROL PANELS &
SWITCHGEAR SECTION
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. June 2022
PAGE GS VHP-15
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. June 2022
PAGE GS VHP-16
FOR DESCRIPTIONS AND DETAILS OF CONTROL PANEL AND SWITCHGEAR OFFERINGS PLEASE REFER TO CONTROL PANELS &
SWITCHGEAR SECTION
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. June 2022
PAGE GS VHP-17
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. June 2022
PAGE GS VHP-18
FOR DESCRIPTIONS AND DETAILS OF CONTROL PANEL AND SWITCHGEAR OFFERINGS PLEASE REFER TO CONTROL PANELS &
SWITCHGEAR SECTION
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. June 2022
PAGE GS VHP-19
7100GSID S4 7104GSID
7100GSI S4, 7104GSI
5904LT/LTD
9504GSI S5
3604GSID
5904GSID
3604GSI
5904GSI
Code MODEL VHP 3604, 5904, 7104, 7100, and 9504 ACCESSORIES
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. June 2022
PAGE GS VHP-20
7100GSID S4 7104GSID
7100GSI S4, 7104GSI
5904LT/LTD
9504GSI S5
3604GSID
5904GSID
3604GSI
5904GSI
Code MODEL VHP 3604, 5904, 7104, 7100, and 9504 ACCESSORIES
1008A X X X emPact Emission Control System -- Adds shipped-loose 3-way catalyst sized to
achieve 1.0 g/bhp-hr NOx and 1.0 g/bhp-hr CO. Includes one 33.5 inch (85.09
cm) element. Carbon steel catalyst housing with 16 inch (40.6 cm) diameter inlet
and outlet flanges. Distance from Inlet flange to outlet flange is 62 inches (157.5
cm). Housing can be oriented so element access door is removed vertically (12
o'clock) or horizontally (3 or 9 o'clock). Wiring harness must be mounted at either 3
or 9 o'clock. Housing must be mounted horizontally. emPact adds the following to
standard AFR2: post-catalyst O2 sensor for closed-loop air/fuel ratio control to
adjust air/fuel ratio based on catalyst output, and pre- and post-catalyst temperature
and pressure sensors for simplified maintenance and emission reporting. Includes
one flexible connection with 13" (33 cm) length and 16" (40.6 cm) diameter flanges
and housing mounting brackets.................................................................................
1008B X X X emPact Emission Control System -- Adds shipped-loose 3-way catalyst sized to
achieve 0.15 g/bhp-hr NOx and 0.30 g/bhp-hr CO. Includes two 33.5 inch (85.09
cm) elements. Carbon steel catalyst housing with 16 inch (40.6 cm) diameter inlet
and outlet flanges. Distance from Inlet flange to outlet flange is 62 inches (157.5
cm). Housing can be oriented so element access door is removed vertically (12
o'clock) or horizontally (3 or 9 o'clock). Wiring harness must be mounted at either 3
or 9 o'clock. Housing must be mounted horizontally. emPact adds the following to
standard AFR2: post-catalyst O2 sensor for closed-loop air/fuel ratio control to
adjust air/fuel ratio based on catalyst output, and pre- and post-catalyst temperature
and pressure sensors for simplified maintenance and emission reporting. Includes
one flexible connection with 13" (33 cm) length and 16" (40.6 cm) diameter flanges
and housing mounting brackets.................................................................................
1008SA X X X emPact Emission Control System -- Adds shipped-loose 3-way catalyst sized to
achieve 1.0 g/bhp-hr NOx and 1.0 g/bhp-hr CO. Includes one 33.5 inch (85.09
cm) element. Stainless steel catalyst housing with 16 inch (40.6 cm) diameter
inlet and outlet flanges. Distance from Inlet flange to outlet flange is 62 inches (157.5
cm). Housing can be oriented so element access door is removed vertically (12
o'clock) or horizontally (3 or 9 o'clock). Wiring harness must be mounted at either 3
or 9 o'clock. Housing must be mounted horizontally. emPact adds the following to
standard AFR2: post-catalyst O2 sensor for closed-loop air/fuel ratio control to
adjust air/fuel ratio based on catalyst output, and pre- and post-catalyst temperature
and pressure sensors for simplified maintenance and emission reporting. Includes
one flexible connection with 13" (33 cm) length and 16" (40.6 cm) diameter flanges
and housing mounting brackets.................................................................................
1008SB X X X emPact Emission Control System -- Adds shipped-loose 3-way catalyst sized to
achieve 0.15 g/bhp-hr NOx and 0.30 g/bhp-hr CO. Includes two 33.5 inch (85.09
cm) elements. Stainless steel catalyst housing with 16 inch (40.6 cm) diameter
inlet and outlet flanges. Distance from Inlet flange to outlet flange is 62 inches (157.5
cm). Housing can be oriented so element access door is removed vertically (12
o'clock) or horizontally (3 or 9 o'clock). Wiring harness must be mounted at either 3
or 9 o'clock. Housing must be mounted horizontally. emPact adds the following to
standard AFR2: post-catalyst O2 sensor for closed-loop air/fuel ratio control to
adjust air/fuel ratio based on catalyst output, and pre- and post-catalyst temperature
and pressure sensors for simplified maintenance and emission reporting. Includes
one flexible connection with 13" (33 cm) length and 16" (40.6 cm) diameter flanges
and housing mounting brackets.................................................................................
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. June 2022
PAGE GS VHP-21
7100GSID S4 7104GSID
7100GSI S4, 7104GSI
5904LT/LTD
9504GSI S5
3604GSID
5904GSID
3604GSI
5904GSI
Code MODEL VHP 3604, 5904, 7104, 7100, and 9504 ACCESSORIES
1009A X emPact Emission Control System -- Adds shipped-loose 3-way catalyst sized to
achieve 1.0 g/bhp-hr NOx and 1.0 g/bhp-hr CO. Includes one 37.5 inch (95.25
cm) element. Carbon steel catalyst housing with 20 inch (50.8 cm) diameter
inlet and outlet flanges. Distance from Inlet flange to outlet flange is 73 inches
(185.4 cm). Housing can be oriented so element access door is removed
vertically (12 o'clock) or horizontally (3 or 9 o'clock). Wiring harness must be
mounted at either 3 or 9 o'clock. Housing must be mounted horizontally. emPact
adds the following to standard AFR2: post-catalyst O2 sensor for closed-loop
air/fuel ratio control to adjust air/fuel ratio based on catalyst output, and pre- and
post-catalyst temperature and pressure sensors for simplified maintenance and
emission reporting. Includes one flexible connection with 13" (33 cm) length and
20" (50.8 cm) diameter flanges and housing mounting brackets ............................
1009B X emPact Emission Control System -- Adds shipped-loose 3-way catalyst sized to
achieve 0.15 g/bhp-hr NOx and 0.30 g/bhp-hr CO. Includes two 37.5 inch
(95.25 cm) elements. Carbon steel catalyst housing with 20 inch (50.8 cm)
diameter inlet and outlet flanges. Distance from Inlet flange to outlet flange is 73
inches (185.4 cm). Housing can be oriented so element access door is removed
vertically (12 o'clock) or horizontally (3 or 9 o'clock). Wiring harness must be
mounted at either 3 or 9 o'clock. Housing must be mounted horizontally. emPact
adds the following to standard AFR2: post-catalyst O2 sensor for closed-loop
air/fuel ratio control to adjust air/fuel ratio based on catalyst output, and pre- and
post-catalyst temperature and pressure sensors for simplified maintenance and
emission reporting. Includes one flexible connection with 13" (33 cm) length and
20" (50.8 cm) diameter flanges and housing mounting brackets ............................
1009SA X emPact Emission Control System -- Adds shipped-loose 3-way catalyst sized to
achieve 1.0 g/bhp-hr NOx and 1.0 g/bhp-hr CO. Includes one 37.5 inch (95.25
cm) element. Stainless steel catalyst housing with 20 inch (50.8 cm) diameter
inlet and outlet flanges. Distance from Inlet flange to outlet flange is 73 inches
(185.4 cm). Housing can be oriented so element access door is removed
vertically (12 o'clock) or horizontally (3 or 9 o'clock). Wiring harness must be
mounted at either 3 or 9 o'clock. Housing must be mounted horizontally. emPact
adds the following to standard AFR2: post-catalyst O2 sensor for closed-loop
air/fuel ratio control to adjust air/fuel ratio based on catalyst output, and pre- and
post-catalyst temperature and pressure sensors for simplified maintenance and
emission reporting. Includes one flexible connection with 13" (33 cm) length and
20" (50.8 cm) diameter flanges and housing mounting brackets ............................
1009SB X emPact Emission Control System -- Adds shipped-loose 3-way catalyst sized to
achieve 0.15 g/bhp-hr NOx and 0.30 g/bhp-hr CO. Includes two 37.5 inch
(95.25 cm) elements. Stainless steel catalyst housing with 20 inch (50.8 cm)
diameter inlet and outlet flanges. Distance from Inlet flange to outlet flange is 73
inches (185.4 cm). Housing can be oriented so element access door is removed
vertically (12 o'clock) or horizontally (3 or 9 o'clock). Wiring harness must be
mounted at either 3 or 9 o'clock. Housing must be mounted horizontally. emPact
adds the following to standard AFR2: post-catalyst O2 sensor for closed-loop
air/fuel ratio control to adjust air/fuel ratio based on catalyst output, and pre- and
post-catalyst temperature and pressure sensors for simplified maintenance and
emission reporting. Includes one flexible connection with 13" (33 cm) length and
20" (50.8 cm) diameter flanges and housing mounting brackets ............................
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. June 2022
PAGE GS VHP-22
7100GSID S4 7104GSID
7100GSI S4, 7104GSI
5904LT/LTD
9504GSI S5
3604GSID
5904GSID
3604GSI
5904GSI
Code MODEL VHP 3604, 5904, 7104, 7100, and 9504 ACCESSORIES
NOTE: Code 1102B is available only for units with water connections for remote
radiators. Units can only be tested with 200° F. (93° C.) maximum (solid water).
1102B X Hot water cooling system, 235° F (113° C) maximum engine outlet temperature.
Required for jacket water outlet temperatures above 210° F (99° C). Consult
standard sheet S7424-1 for required water pump inlet pressure. Includes special
cylinder head–to–exhaust manifold water jacket connections, and high
temperature coupling seals. Jacket water thermostats are omitted. CUSTOMER
MUST PROVIDE ENGINE PROTECTION SHUTDOWN EQUIPMENT FOR LOW
WATER LEVEL AND LOSS OF WATER CIRCULATION. (Consult factory for
delivery lead time.) ....................................................................................................
1106 X X X X X X X X Auxiliary water circuit thermostatic valve for 140° F (60° C) intercooler water
temperature. Replaces standard auxiliary water circuit thermostatic valve for 130°
F (54°C) intercooler water temperature ...................................................................
1107B X High Temperature Thermostats – 220° F (104° C) jacket water thermostats and
high temperature jacket water system seals. For use with digester/landfill gas fuel
systems if Code 1102 is not specified. Lube oil thermostats are 190° F (88°C).
Consult the Application Engineering Department for recommendation on jacket
water temperature requirements before ordering this code. Independent source
cooling water is required for lube oil cooler and/or intercooler. (Consult factory for
delivery lead time.)....................................................................................................
FUEL SYSTEM
Any installation using landfill gas as fuel must
dehydrate the gas by refrigeration followed by
reheating to remove significant amounts of
halogen compounds, siloxanes and water. Reference WAUKESHA Gaseous Fuel
Specification, S7884–7 (or latest revision), in the Waukesha Engine General
Technical Data Book.
2020F X Landfill Gas Fuel System for LTD – (LHV 400 – 550 BTU/ft3) – Deletes standard
fuel system. Includes 220° F jacket water thermostats, 190° F lube oil
thermostats, engine valves and main and rod bearings designed for corrosion
resistance. Adds two gas 4” updraft carburetors, two 4” Fisher 66 gas regulators
(shipped loose), two 4” 125 lb. flanged flexible connections (shipped loose), and
one 4” 125 lb. flanged CP Maxon solenoid valve (shipped loose). Fuel pressure
– 1.50 PSIG minimum and 10 PSIG maximum Contact Sales Engineering for
VHP5904LTD power derate .....................................................................................
2020G X Digester Gas fuel system for LTD – (LHV 550 – 650 Btu/ft3) – Deletes standard fuel
system. Includes 220° F jacket water thermostats, and 190°F lube oil
thermostats. Adds two gas 3.5” updraft carburetors, two 4” Fisher 66 gas
regulators (shipped loose), two 4” to 3.5” 125 lb. flanged reducing flexible
connections (shipped loose), and one 4” 125 lb flanged CP Maxon solenoid valve
(shipped loose). Fuel pressure 1.50 psig minimum to 10 psig maximum. Contact
Application Engineering for VHP5904LTD power derate. .......................................
2200 X X Low Btu Fuel System -- Fuel system for fuels with heating values from 700-850
Btu/ft3. Includes modified carburetor and spring. ....................................................
2314B X Omit Standard Air Cleaner – Cannot use with Code 2316 .........................................
2314C X Remote Air Cleaner – Allows for off-engine mounting of air cleaner. Shipped loose.
Does not include rain shield. Includes heavy duty inertia separator precleaners.
Requires final piping by customer ............................................................................
2314D X Remote Air Cleaner – Allows for off-engine mounting of air cleaner. Shipped loose.
Does not include heavy duty inertia precleaners. Includes rain shield. Requires
final piping by customer ............................................................................................
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. June 2022
PAGE GS VHP-23
7100GSID S4 7104GSID
7100GSI S4, 7104GSI
5904LT/LTD
9504GSI S5
3604GSID
5904GSID
3604GSI
5904GSI
Code MODEL VHP 3604, 5904, 7104, 7100, and 9504 ACCESSORIES
2314E X Air cleaners shipped-loose for on-engine mounting. Includes support bracket that
must be removed once air cleaners are installed ....................................................
2316 X Weather, Louver – For unsheltered installation and average dust environment
(shipped loose). ........................................................................................................
2320B X X X X X X X X Precleaner – Heavy duty inertia separator, for standard air cleaner. .........................
2350 X X Air Cleaner Housing Modification for Remote Air Intakes -- Modified air cleaner to
allow intake air to be piped from outside enclosure while leaving air filters on
engine. Required on 12-cylinder GSI, LT, and GL engines for proper operation of
breather system when using remote air intakes. Provides 5.5-inch (139.7 mm)
diameter connection to flexible hose for servicing of air filter element without
disconnecting customer piping. Cannot be used with Code 2320B or on engines
with draw-through fuel systems................................................................................
ELECTRICAL SYSTEM
Generator Options:
3009 X 4160V Generator – Deletes 480V, 60 Hz generator and adds 4160V, 60 Hz
generator. Please contact factory for generator alternatives in 50 Hz applications
...................................................................................................................................
3046 X X X X Cross Current Compensation – For reactive load control when parallel operation is
required. Includes current transformer (shipped loose). Not required with
ECP8000 ...................................................................................................................
3050A X X X Digital voltage regulator with integral VAR/Power Factor control (shipped loose), for
paralleling with utility. Includes voltage adjust switch (shipped loose). Replaces
standard voltage regulator. Not required with ECP8000 ........................................
3068 X X X X X X X X Winding Temperature and Generator Bearing Temperature Detector-100 ohm
platinum resistive temperature detector (RTD), with a temperature coefficient of
0.00385 ohms/ohm/°C, one per phase, total of three, and one bearing.................
3433E X X X X X X X X X Alternator – Denso, 24V DC, 50A, Brushless, belt driven direct off crankshaft.
Includes engine mounted junction box for connection to battery. Alternator system
meets Canadian Standard Association Class I, Division 2, Group D, hazardous
location requirements ...............................................................................................
COOLING SYSTEM
4061 X X Jacket Water Heater – One 4500W 240V AC/1/50-60, thermostatically controlled,
automatically disconnected when engine is running. Wired to AC junction box.
REQUIRED FOR AMBIENT TEMPERATURES BELOW 70° F (21° C). For
ambients down to approximately 40° F (4° C) .........................................................
4062 X X X X X X Jacket Water Heater – Two 4500W 240V AC/1/50-60, thermostatically controlled,
automatically disconnected when engine is running. Wired to AC junction box.
REQUIRED FOR AMBIENT TEMPERATURES BELOW 70° F (21° C). For
ambients down to approximately 40° F (4° C) .........................................................
4306 X Isolator flex connect pack for jacket water and aux water cooling .............................
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. June 2022
PAGE GS VHP-24
7100GSID S4 7104GSID
7100GSI S4, 7104GSI
5904LT/LTD
9504GSI S5
3604GSID
5904GSID
3604GSI
5904GSI
Code MODEL VHP 3604, 5904, 7104, 7100, and 9504 ACCESSORIES
LUBRICATION SYSTEM
5110A X X X X X X X X Air Motor Driven Prelube – Deletes electric prelube. Includes 24V DC pilot solenoid
valve ..........................................................................................................................
5110B X Air Motor Driven Prelube – Deletes electric prelube. Includes 24V DC pilot solenoid
valve ..........................................................................................................................
5203 X X X X X X X X X Lubrication Oil Level Regulator – Kenco .....................................................................
5204 X X X X X X X X Lubrication Oil Level Regulator – Kenco with totalizing flow meter. Includes quick
fill valve Code 5205. (Unit readout in gallons.) ........................................................
5204A X X X X X X X X Lubrication Oil Level Regulator – Kenco with totalizing flow meter. Includes quick
fill valve Code 5205. (Unit readout in liters.) ............................................................
5205 X X X X X X X X X Quick fill valve and piping to bypass lube oil regulator. Requires Code 5203 ...........
5230 X X X X X X X X X 24VDC Pre-lube Motor. Replaces standard 230VAC motor ......................................
WARNING AND SHUTDOWN SENSORS – UNIT MOUNTED
(Contact rating is 2A, 24V DC resistive)
6012 X X X X X X X X Valve – BICERA crankcase explosion relief. Four (4) required ..................................
6012C X Valve – BICERA crankcase explosion relief. Quantity six (6) required ......................
6106D X X X X X X X X X Engine Vibration Sensor with 4-20mA output. Includes mounting and wiring to a
NEMA 4 junction box .................................................................................................
6109 X X X X X X X X X Low lube oil level warning switch. Requires code 5203 or 5204. ...............................
6109B X X X X X X X X X Oil level switch – High & low level shutdown ..............................................................
6201C X X X X X X X X X Pressure sensor with 4-20mA output. Includes mounting and wiring to a NEMA 4
junction box of jacket water and fuel pressure transmitters.....................................
6201D X X X X X X X X X Thermocouples, Type K – Includes mounting and wiring to a NEMA 4 junction box
of fuel and auxiliary water. ........................................................................................
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. June 2022
PAGE GS VHP-25
7100GSID S4 7104GSID
7100GSI S4, 7104GSI
5904LT/LTD
9504GSI S5
3604GSID
5904GSID
3604GSI
5904GSI
Code MODEL VHP 3604, 5904, 7104, 7100, and 9504 ACCESSORIES
6926A X Thermocouples, Type K – For exhaust temperatures. 7 points. Includes 25ft (7.6
m) harness (Ref. code 6650B for 50 ft. harness) ....................................................
6926B X X X Thermocouples, Type K – For exhaust temperatures. 14 points. Includes 25ft (7.6
m) harness (Ref. code 6650B for 50 ft. harness) ....................................................
ESM2 CONTROLS (Codes in this section are ESM2-Specific Codes and apply
only to 3604GSI, 5904GSI, 7100GSI S4, 7104GSI, 7104GSI/D S5, 7100GSI/D
S5, and 9504GSI S5 Enginators)
6690D X X X X X 25' (7.6 m) ECP8000 Customer Access Harness for customer connections, on
ESM2, ECP8000-equipped Enginators. Replaces standard 50’ (15.2 m)
Customer Access Harness .......................................................................................
6690E X X X X X 100’ (30.4 m) ECP8000 Customer Access Harness for customer connections, on
ESM2, ECP8000-equipped Enginators. Replaces standard 50’ (15.2 m)
Customer Access Harness ...................................................................................... .
6690F X X X X X 200’ (60.8 m) ECP8000 Customer Access Harness for customer connections, on
ESM2, ECP8000-equipped Enginators. Replaces standard 50’ (15.2 m)
Customer Access Harness. ......................................................................................
EXHAUST SYSTEM
Silencer – Residential Ratings – Shipped loose.
NOTE: Sizing is at standard kW ratings. Operation at non–standard ratings will affect
silencer requirements. Exhaust system back pressure calculations must be made
for all applications. Contact factory for further information.
7010 X X 10″ (254 mm) flanged end inlet and end outlet. For 3604GSI/GSID @ 1000/1200
rpm ............................................................................................................................
7012 X X X X X X 12″ (305 mm) flanged end inlet and end outlet. For 5904GSI/GSID/LT/LTD @
1000/1200 rpm or 7104GSI/GSID @ 1000/1200 rpm .............................................
7016 X 16″ (406 mm) flanged end inlet, and end outlet. For 9504GSI S5 @ 1000/1200 rpm
...................................................................................................................................
STARTING SYSTEM
9000C X X Three electric starting motors, 24 volt, solenoid engagement. Includes pneumatic
prelube unless optional electric motor driven prelube pump is specified. ..............
9200 X X X X X X X X X Pressure Reducing Regulator – To provide regulated air pressure to the air start
system when supply air pressure is between 150 and 300 PSIG (10.5 and 21
kg/cm2). Shipped loose .............................................................................................
9208 X X X X X X X X Starter – High pressure, air or gas TDI T109, inertia engaged, mounted with strainer
and valve. Minimum supply pressure 90 psi. Maximum supply pressure 150 psi.
9208A X X X X X X X X Starter – Low pressure, air or gas TDI T115, inertia engaged, mounted with strainer
and valve. Minimum supply pressure 50 psi. Maximum supply pressure 90 psi.
Includes 24VDC start valve. .....................................................................................
9208B X Starter – High pressure, air or gas TDI T112, pre-engaged, mounted with strainer
and valve. Minimum supply pressure 90 psi. Maximum supply pressure 150 psi .
9208C X Starter – Low pressure air or gas TDI T121, pre-engaged, mounted with strainer
and valve. Minimum supply pressure 50 psi. Maximum supply pressure 90 psi ...
9300 X X X X X X X X X Flexible Air Supply Connection – One, stainless steel. 1-1/2 inch (38 mm) dia., male
NPT connection, 14 inches (356 mm) long. Shipped loose ....................................
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. June 2022
PAGE GS VHP-26
7100GSID S4 7104GSID
7100GSI S4, 7104GSI
5904LT/LTD
9504GSI S5
3604GSID
5904GSID
3604GSI
5904GSI
Code MODEL VHP 3604, 5904, 7104, 7100, and 9504 ACCESSORIES
BASES
9510A X X Vibration Isolators – Spring type. For 6 cylinder units with single bearing generators.
Requires Code 9516A base modification, and a longer than standard exhaust flex
connection (not supplied). (For seismic zone applications other than Zone 0,
contact Application Engineering). Shipped loose ....................................................
9510B X X X X X X X X Vibration Isolators – Spring type. Same as Code 9510A, except for 6 cylinder units
with 2 bearing generators, and 12 cylinder units with single bearing generators.
(For seismic zone applications other than Zone 0, contact Application
Engineering). .............................................................................................................
9510C X Vibration Isolators – Spring type. For 16 cylinder units. (For seismic zone
applications other than Zone 0, contact Application Engineering). .........................
9512 X X X X X X X X X Jacking bolts – for leveling unit base in the field. Quantity (8), 4 per side ................
9516A X X Outrigger style base modification – For greater stability and reduced height for units
which will be mounted on vibration isolators. Additions to the standard base
include outrigger mounting feet extending from the sides of the unit to provide a
wider and lower footprint. For isolators add Code 9510A. If customer supplied
isolators are to be used, Waukesha will submit the style, type, quality and number
of isolators required). (For seismic zone applications other than Zone 0, contact
Application Engineering)...........................................................................................
MISCELLANEOUS
9974Q X X X X X X X X X Engine/Enginator that is Customs Union Compliant (Russia, Belarus, and
Kazakhstan). Includes SERIAL NUMBER SPECIFIC Technical Passport &
Safety Justification in Russian and English, Engine Operator's Manuals (one in
Russian and one in English), and EAC label on unit. Enginators include
supplied equipment manuals that are in English only. May require additional
lead time, consult factory for delivery information ...................................................
9974V X X X X X X X X X Enginator that is CE Mark Compliant. Includes CE Mark Label, the following
documentation in both English and language of country of final installation,
order to state required language; SERIAL NUMBER SPECIFIC Declaration of
Conformance, Operator, Generator and Voltage Regulator Manuals. All other
supporting documentation is supplied in English only. Contact Applications/
Sales if the sale requires additional translation requirements. May require
additional lead time and cost, consult factory for delivery information ...................
9990 X X X X X X X X X Waukesha standard paint quality to match customer supplied paint chip.
Requires FED-STD-595B or 595C ...........................................................................
EXTENDED WARRANTY
10009AA X X 6-Cylinder VHP Enginator Extended Warranty -- 1 Year. Extended warranty
excludes wear items and includes only warrantable items as defined in Express
Limited Warranty (ELW). Must be purchased at time of original order. If
applicable, the proper deferral process and preservation as outlined in Service
Bulletin 16-1855H (or most current) and WEDA 542 (or most current) must be
followed or warranty extension is void. Pricing applies for standard generators.
Contact Application Engineering for Extended Warranty pricing on non-standard
generators. Emission warranties for Waukesha’s emPact Emission Control
System are NOT EXTENDED by Extended Engine Warranties .............................
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. June 2022
PAGE GS VHP-27
7100GSID S4 7104GSID
7100GSI S4, 7104GSI
5904LT/LTD
9504GSI S5
3604GSID
5904GSID
3604GSI
5904GSI
Code MODEL VHP 3604, 5904, 7104, 7100, and 9504 ACCESSORIES
10009BB X X 6-Cylinder VHP Enginator Extended Warranty -- 2 Years. Extended warranty
excludes wear items and includes only warrantable items as defined in Express
Limited Warranty (ELW). Must be purchased at time of original order. If
applicable, the proper deferral process and preservation as outlined in Service
Bulletin 16-1855H (or most current) and WEDA 542 (or most current) must be
followed or warranty extension is void. Pricing applies for standard generators.
Contact Application Engineering for Extended Warranty pricing on non-standard
generators. Emission warranties for Waukesha’s emPact Emission Control
System are NOT EXTENDED by Extended Engine Warranties ............................ .
10009CC X X 6-Cylinder VHP Enginator Extended Warranty -- 3 Years. Extended warranty
excludes wear items and includes only warrantable items as defined in Express
Limited Warranty (ELW). Must be purchased at time of original order. If
applicable, the proper deferral process and preservation as outlined in Service
Bulletin 16-1855H (or most current) and WEDA 542 (or most current) must be
followed or warranty extension is void.. Pricing applies for standard generators.
Contact Application Engineering for Extended Warranty pricing on non-standard
generators. Emission warranties for Waukesha’s emPact Emission Control
System are NOT EXTENDED by Extended Engine Warranties .............................
10010AA X X X X X X 12-Cylinder VHP Enginator Extended Warranty -- 1 Year. Extended warranty
excludes wear items and includes only warrantable items as defined in Express
Limited Warranty (ELW). Must be purchased at time of original order. If
applicable, the proper deferral process and preservation as outlined in Service
Bulletin 16-1855H (or most current) and WEDA 542 (or most current) must be
followed or warranty extension is void. Pricing applies for standard generators.
Pricing applies for standard generators. Contact Application Engineering for
Extended Warranty pricing on non-standard generators. Emission warranties for
Waukesha’s emPact Emission Control System are NOT EXTENDED by
Extended Engine Warranties ....................................................................................
10010BB X X X X X X 12-Cylinder VHP Enginator Extended Warranty -- 2 Years. Extended warranty
excludes wear items and includes only warrantable items as defined in Express
Limited Warranty (ELW). Must be purchased at time of original order. If
applicable, the proper deferral process and preservation as outlined in Service
Bulletin 16-1855H (or most current) and WEDA 542 (or most current) must be
followed or warranty extension is void. Pricing applies for standard generators.
Contact Application Engineering for Extended Warranty pricing on non-standard
generators. Emission warranties for Waukesha’s emPact Emission Control
System are NOT EXTENDED by Extended Engine Warranties .............................
10010CC X X X X X X 12-Cylinder VHP Enginator Extended Warranty -- 3 Years. Extended warranty
excludes wear items and includes only warrantable items as defined in Express
Limited Warranty (ELW). Must be purchased at time of original order. If
applicable, the proper deferral process and preservation as outlined in Service
Bulletin 16-1855H (or most current) and WEDA 542 (or most current) must be
followed or warranty extension is void. Pricing applies for standard generators.
Contact Application Engineering for Extended Warranty pricing on non-standard
generators. Emission warranties for Waukesha’s emPact Emission Control
System are NOT EXTENDED by Extended Engine Warranties .............................
10011AA X 16-Cylinder VHP Enginator Extended Warranty -- 1 Year. Extended warranty
excludes wear items and includes only warrantable items as defined in Express
Limited Warranty (ELW). Must be purchased at time of original order. If
applicable, the proper deferral process and preservation as outlined in Service
Bulletin 16-1855H (or most current) and WEDA 542 (or most current) must be
followed or warranty extension is void. Pricing applies for standard generators.
Contact Application Engineering for Extended Warranty pricing on non-standard
generators. Emission warranties for Waukesha’s emPact Emission Control
System are NOT EXTENDED by Extended Engine Warranties .............................
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. June 2022
PAGE GS VHP-28
7100GSID S4 7104GSID
7100GSI S4, 7104GSI
5904LT/LTD
9504GSI S5
3604GSID
5904GSID
3604GSI
5904GSI
Code MODEL VHP 3604, 5904, 7104, 7100, and 9504 ACCESSORIES
10011BB X 16-Cylinder VHP Enginator Extended Warranty -- 2 Years. Extended warranty
excludes wear items and includes only warrantable items as defined in Express
Limited Warranty (ELW). Must be purchased at time of original order. If
applicable, the proper deferral process and preservation as outlined in Service
Bulletin 16-1855H (or most current) and WEDA 542 (or most current) must be
followed or warranty extension is void. Pricing applies for standard generators.
Contact Application Engineering for Extended Warranty pricing on non-standard
generators. Emission warranties for Waukesha’s emPact Emission Control
System are NOT EXTENDED by Extended Engine Warranties .............................
10011CC X 16-Cylinder VHP Enginator Extended Warranty -- 3 Years. Extended warranty
excludes wear items and includes only warrantable items as defined in Express
Limited Warranty (ELW). Must be purchased at time of original order. If
applicable, the proper deferral process and preservation as outlined in Service
Bulletin 16-1855H (or most current) and WEDA 542 (or most current) must be
followed or warranty extension is void. Pricing applies for standard generators.
Contact Application Engineering for Extended Warranty pricing on non-standard
generators. Emission warranties for Waukesha’s emPact Emission Control
System are NOT EXTENDED by Extended Engine Warranties .............................
DISCLAIMER
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. June 2022
PAGE GS VGF-1
*** Radiator: Based on 100° F (38° C) ambient, 1500 ft (457m) elevation, using 50/50% water/ethylene glycol solution.
**** Allows 5% overload. Required pipeline quality natural gas with a minimum of 850 Btu/ft3 SLHV.
Radiator will not be tested during standard production test or witness test.
Rating Standard: All models: Ratings conform to ISO 3046/1 (latest version) with a mechanical efficiency of 90% and auxiliary water temperature, Tcra,
as specified in the Power Rating Chart, Bulletin 1079 (latest version) limited to ±10° F (±5.5° C). Ratings are also valid for SAE J1349, BS 5514, DIN 6271
and API 7B-11C standard atmospheric reference conditions.
Fuel Standard: All natural gas engine ratings are based on 900 BTU/ft3 (35.38 MJ/m3 [25, V(0; 101.325)]) SLHV, 91 WKI* minimum, commercial quality
natural gas. Refer to S-7884-7 (latest version) for full gaseous fuel specifications.
Generator Continuous Power Rating (kWe): The highest load and speed which can be applied 24 hours per day, seven days per week, 365 days per year
except for normal maintenance. No overload allowed.
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. July 2022
PAGE GS VGF-2
*** Radiator: Based on 100° F (38° C) ambient, 1500 ft (457m) elevation, using 50/50% water/ethylene glycol solution.
**** Allows 5% overload. Required pipeline quality natural gas with a minimum of 850 Btu/ft3 SLHV.
Radiator will not be tested during standard production test or witness test.
Rating Standard: All models: Ratings conform to ISO 3046/1 (latest version) with a mechanical efficiency of 90% and auxiliary water temperature,
Tcra, as specified in the Power Rating Chart, Bulletin 1079 (latest version) limited to ±10° F (±5.5° C). Ratings are also valid for SAE J1349, BS 5514,
DIN 6271 and API 7B-11C standard atmospheric reference conditions.
Fuel Standard: All natural gas engine ratings are based on 900 BTU/ft3 (35.38 MJ/m3 [25, V(0; 101.325)]) SLHV, 91 WKI* minimum, commercial
quality natural gas. Refer to S-7884-7 (latest version) for full gaseous fuel specifications.
Generator Continuous Power Rating (kWe): The highest load and speed which can be applied 24 hours per day, seven days per week, 365 days per
year except for normal maintenance. No overload allowed.
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. July 2022
PAGE GS VGF-3
JUNCTION BOXES – Separate AC & DC junction boxes for engine VOLTAGE REGULATOR – Digital type
wiring and external connections. DOCUMENTATION - The following items are supplied as standard
LUBRICATION SYSTEM – Gear type pump, full flow spin–on filters with every order:
and industrial base type oil pan, 44 gallon (166 liters) capacity, – Electronic notification and access to drawings for review and or
including filters. Engine mounted plate type oil cooler and centrifugal approval.
bypass filter. Includes 240VAC prelube pump (mounted). – One Enginator® manual consisting of:
• Engine operation/service manual.
PAINT – Oilfield Orange topcoat.
• Engine parts book.
PISTONS – Aluminum alloy, three ring, with deep central combustion
• Generator/voltage regulator instructions.
bowl. Oil jet cooled with full floating piston pin. 8.6:1 compression
• Instructions on major special items.
ratio.
STARTING SYSTEM – 24V DC starting motor.
TURBOCHARGER – Exhaust driven, dry type with differential wastegate.
For 1400 – 1800 rpm applications.
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. July 2022
PAGE GS VGF-5
EMISSION CONTROL
1004B X X emPact Emission Control System — Adds shipped-loose 3-way catalyst sized to achieve 0.50 g/bhp-hr NOx and
1.0 g/bhp-hr CO. Stainless steel housing includes 1 element. Catalyst element access door is on top of housing.
emPact also adds the following to standard AFR2: post-catalyst O2 sensor for closed-loop air/fuel ratio control to
adjust air/fuel ratio based on catalyst output, and pre- and post-catalyst temperature and pressure sensors for
simplified maintenance and emission reporting ............................................................................................................
1005B X X emPact Emission Control System — Adds shipped-loose, 3-way catalyst sized to achieve 0.15
g/bhp-hr NOx
and 0.3 g/bhp hr CO. Stainless steel housing includes 2 elements.
emPact also adds the following to standard
AFR2: post-catalyst O2 sensor for closed-loop
air/fuel ratio control to adjust air/fuel ratio based on catalyst
output, and pre- and post-
catalyst temperature and pressure sensors for simplified maintenance and
emission reporting. .......................................................................................................................................................
FUEL SYSTEM
2022 Gas Regulator: 2” NPT Knockdown regulator for Low Pressure fuel (outlet 3-10 psi / inlet 20-200 psi).
X X
Shipped Loose ............................................................................................................................................................
2034D X X Dual Fuel System: Natural gas/field gas and LP(HD-5). Allows the engine to automatically or manually switch
from natural/field gas to liquid propane (LP) without shutting down. Engine mounted vaporizers, MAS (valve),
pressure relief valve, fuel pressure sensor, and switching solenoids. Switching controls included. LP fuel
pressure 30-300PSIG. See S-07546-40 for further fuel specifications. System engine mounted. .......................
2048A X X Low Btu Fuel System -- Fuel system (Carburetor) for fuels with heating values from 650-850 Btu/ft3 LHV ............
AIR CLEANERS
2320D X X Precleaner, Heavy Duty inertial separator, for standard air cleaner. Removes std. Air cleaner Rain Shield ........
NOTE: Precleaners are recommended for applications in dusty environments or when dust conditions are
unpredictable.
ELECTRICAL
3433G X X Alternator – Denso, 24V DC, 50 amp, brushless, belt driven. Crankshaft pulley Code 8107 and drive belts are
included. Alternator system meets CSA Class I, Division 2, Group A, B, C & D (Canada & US) hazardous
location requirements. Cannot be used with Code 4290B ...................................................................
COOLING
4281D X X Jacket Water Preheater – Thermostatically controlled, (100° F on; 120° F off), 240V AC, single phase, 6000
watts. Customer supplied logic & shipped loose. (Min/Max ambient temperature 4°F – 104°F) ........................
4300 X Flexible Water Connections for Solid Mounted Water Connect Units – Includes 2 jacket water, and 2 auxiliary
water stainless steel flexes. (Shipped loose).......................................... ..............................................................
4300A X Flexible Water Connections for Isolator Mounted Water Connect Units – Includes 2 jacket water, and 2 auxiliary
water stainless steel flexes. (Shipped loose) .........................................................................................................
4660A X Removal of unit mounted radiator to meet customer’s shipping requirements ........................................................
LUBRICATION
5022C X X Regulator – Lubricating oil level. Kenco model LCE with explosion-proof electric low level SPDT safety switch
and Fire Safe features. Meets CSA Class I, Division 2, Group B, C, & D requirements. For oil supply with up
to 15ft. of static head. Mounted in place of standard crankcase inspection door .................................................
5205D X X Prelube Pump – Electric prelube pump for prelube and post lube. Engine mounted. Includes 24V DC motor
driven pre-lube pump. Continuous prelube not available .....................................................................................
5205E X X Prelube Pump - Air Driven prelube pump for prelube and post lube. Engine mounted, air/gas motor-driven. ......
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. July 2022
PAGE GS VGF-6
Genset RAD
Genset WC
CONTROLS
6018 X X Load Sharing dongle for multiple units in island operation. ......................................................................................
6190 X X Magnetic Pickup – Mounted. ......................................................................................................................................
6215 X X Sensor Package, includes
- Temps for exhaust (ea cyl + pre + post), aux water inlet, fuel, gen windings and bearing
- Pressure for JW and fuel
- Water level – JW and Aux
- Oil Level – High and Low
- Engine Vibration..............................................................................................................................................
6302A X X Battery Charger, 20 amp – Shipped Loose. Static, float/equalize type with DC ammeter and DC voltmeter. 230V
AC, 1 ph 50/60 Hz input, 24V DC output. For lead–acid batteries only. Supplied in a NEMA enclosure for
separate remote mounting. .....................................................................................................................................
6951 X X Adjustable trip circuit breaker (400 / 500 / 600 / 800 Amp). Molded case type thermal long time trip characteristic
(ambient compensated) with magnetic instantaneous trip characteristics with shunt trip and with auxiliary (A
& B) contacts. Generator mounted and cabled for customer power connections. (Circuit breaker rating should
exceed full load rating by 10%.) .............................................................................................................................
6996 X X Utility Mains Circuit Breaker controller, shipped Loose
Only required if control of the utility CB is desired. Shipped loose for installation in customer supplied utility
tie breaker panel. Contact factory if a Waukesha-supplied utility tie breaker panel is needed. Includes the
following features:
-Import / Export control
-Utility Mains CB control and synchronizing generator bus to utility
-Utility Mains electrical protections. ..........................................................................................
BASES
9511A X X Vibration Isolators – Spring Type. Requires a longer than standard exhaust flex connection (not supplied).
(Shipped loose. For seismic zone applications other than Zone 0 contact Application Engineering) ................
MISCELLANEOUS
7006A X X F18SE - Silencer, residential rating, Size 8" flanged, end inlet, end outlet. shipped loose ....................................
7007 X X H24SE - Silencer, residential rating, Size 10" flanged, end inlet, end outlet. shipped loose..................................
7117 X X Exhaust Flex – 8” Flange, Max design press. @ 15000F, 88psi. ..............................................................................
9990 X X Paint Charge for other than Grey or Orange .............................................................................................................
9974Q X X Engine/Enginator that is Customs Union Compliant (Russia, Belarus, and Kazakhstan). Includes SERIAL
NUMBER SPECIFIC Technical Passport & Safety Justification in Russian and English, Engine Operator's
Manuals (one in Russian and one in English), and EAC label on unit. Enginators include supplied equipment
manuals that are in English only. May require additional lead time, consult factory for delivery information.....
9974V X X Enginator that is CE Mark Compliant. Includes CE Mark Label, the following documentation in both English and
language of country of final installation, order to state required language; SERIAL NUMBER SPECIFIC
Declaration of Conformance, Operator, Generator and Voltage Regulator Manuals. All other supporting
documentation is supplied in English only. Contact Applications/Sales if the sale requires additional translation
requirements. May require additional lead time and cost, consult factory for delivery information. ..................
9974X X X Required label for Hazardous Location CSA Certification in US & Canada end use. Adds a safety label
containing English and French language that is required to comply with the certification terms of the
equipment. Note: For end uses classified as Hazardous Locations Division 2 and in US & Canada. Contact
Application Engineering for use in other countries. ...............................................................................................
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. July 2022
PAGE GS VGF-7
Genset RAD
Genset WC
EXTENDED WARRANTY
10012AA X X 6-Cylinder VGF Genset Extended Warranty -- 1 Year. Extended warranty excludes wear items and includes
only warrantable items as defined in Express Limited Warranty (ELW). Must be purchased at time of original
order. If applicable, the proper deferral process and preservation as outlined in Service Bulletin 16-1855H (or
most current) and WEDA 542 (or most current) must be followed or warranty extension is void........................
10012BB X X 6-Cylinder VGF Genset Extended Warranty -- 2 Years. Extended warranty excludes wear items and includes
only warrantable items as defined in Express Limited Warranty (ELW). Must be purchased at time of original
order. If applicable, the proper deferral process and preservation as outlined in Service Bulletin 16-1855H (or
most current) and WEDA 542 (or most current) must be followed or warranty extension is void........................
10012CC X X 6-Cylinder VGF Genset Extended Warranty -- 3 Years. Extended warranty excludes wear items and includes
only warrantable items as defined in Express Limited Warranty (ELW). Must be purchased at time of original
order. If applicable, the proper deferral process and preservation as outlined in Service Bulletin 16-1855H (or
most current) and WEDA 542 (or most current) must be followed or warranty extension is void........................
10013AA X X 8-Cylinder VGF Genset Extended Warranty -- 1 Year. Extended warranty excludes wear items and includes
only warrantable items as defined in Express Limited Warranty (ELW). Must be purchased at time of original
order. If applicable, the proper deferral process and preservation as outlined in Service Bulletin 16-1855H (or
most current) and WEDA 542 (or most current) must be followed or warranty extension is void........................
10013BB X X 8-Cylinder VGF Genset Extended Warranty -- 2 Years. Extended warranty excludes wear items and includes
only warrantable items as defined in Express Limited Warranty (ELW). Must be purchased at time of original
order. If applicable, the proper deferral process and preservation as outlined in Service Bulletin 16-1855H (or
most current) and WEDA 542 (or most current) must be followed or warranty extension is void........................
10013CC X X 8-Cylinder VGF Genset Extended Warranty -- 3 Years. Extended warranty excludes wear items and includes
only warrantable items as defined in Express Limited Warranty (ELW). Must be purchased at time of original
order. If applicable, the proper deferral process and preservation as outlined in Service Bulletin 16-1855H (or
most current) and WEDA 542 (or most current) must be followed or warranty extension is void........................
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. July 2022
PAGE GS VGF-8
FOR DESCRIPTIONS AND DETAILS OF CONTROL PANEL AND SWITCHGEAR OFFERINGS PLEASE REFER TO CONTROL PANELS &
SWITCHGEAR SECTION
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. July 2022
PAGE GS VGF-9
FOR DESCRIPTIONS AND DETAILS OF CONTROL PANEL AND SWITCHGEAR OFFERINGS PLEASE REFER TO CONTROL PANELS &
SWITCHGEAR SECTION
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. July 2022
PAGE GS VGF-10
P48
F18
L36
FUEL SYSTEM
2095 X X Fuel System GLD – Low BTU gas 400 - 500 BTU – Deletes standard fuel system. Adds one low BTU gas
carburetor, one 4˝ Fisher 66 gas regulator (shipped loose), one 2˝ NPT flexible connection (shipped
loose) and one 2.5˝ 125 lb flanged Maxon gas solenoid valve (shipped loose). See Power Rating chart
for ratings. Fuel pressure - 20˝ H2O minimum and 10 PSIG maximum .......................................................
2096 X X Fuel System GLD – Low BTU gas 400 - 500 BTU – Deletes standard fuel system. Adds two low BTU gas
carburetors, one 4˝ Fisher 66Z gas regulator (shipped loose), one 4˝ 125 lb. flanged flexible connection
(shipped loose) and one 2.5˝ 125 lb flanged Maxon gas solenoid valve (shipped loose). See Power
Rating chart for ratings. Fuel pressure - 35˝ H2O minimum and 5 PSIG maximum. For use with CEC AFM
........................................................................................................................................................................
2097 X X Fuel System GLD – Low BTU gas 500 - 650 BTU – Deletes standard fuel system. Adds one low BTU gas
carburetor, one 4˝ Fisher 66 gas regulator (shipped loose), one 2˝ NPT flexible connection (shipped loose)
and one 2.5˝ 125 lb flanged Maxon gas solenoid valve (shipped loose). See Power Rating chart for ratings.
Fuel pressure - 20˝ H2O minimum and 10 PSIG maximum............................................................................
2098 X X Fuel System GLD – Low BTU gas 500 - 650 BTU – Deletes standard fuel system. Adds two low BTU gas
carburetors, one 4˝ Fisher 66Z gas regulator (shipped loose), one 4˝ 125 lb. flanged flexible connection
(shipped loose) and one 2.5˝ 125 lb flanged Maxon gas solenoid valve (shipped loose). See Power
Rating chart for ratings. Fuel pressure - 35˝ H2O minimum and 5 PSIG maximum. For use with CEC AFM
........................................................................................................................................................................
2101 X X Dual Fuel System GLD – Natural gas and propane vapor – Deletes standard fuel system. Customer must provide
control for manual or automatic fuel changeover. Adds two gas carburetors, one Fisher 66Z regulator for natural
gas (shipped loose), one 3˝-125 lb flanged flexible connection (shipped loose) and one 3˝ NPT Maxon gas
solenoid valve (shipped loose). Natural gas fuel pressure – 18˝ H2O minimum and 5 PSIG maximum. Adds
one Fisher 66Z regulator for propane vapor (shipped loose), one 2˝ NPT flexible connection (shipped loose)
and one 3˝ NPT Magnatrol gas solenoid valve (shipped loose). See Power Rating chart for ratings. Propane
vapor fuel pressure 18˝ H2O minimum and 5 PSIG maximum ...................................................................................
2102 X X Dual Fuel System GSID – Natural gas and propane vapor – Deletes standard fuel system. Customer must
provide control for manual or automatic fuel changeover. Adds two gas carburetors, one Fisher 66Z regulator
for natural gas (shipped loose), one 3˝-125 lb flanged flexible connection (shipped loose) and one 3˝ NPT
Maxon gas solenoid valve (shipped loose). Natural gas fuel pressure – 18˝ H2O minimum and 5 PSIG
maximum. Adds one Fisher 66Z regulator for propane vapor (shipped loose), one 2˝ NPT flexible connection
(shipped loose) and one 3˝ NPT Magnatrol gas solenoid valve (shipped loose). See Power Rating chart for
ratings. Propane vapor fuel pressure 18˝ H2O minimum and 5 PSIG maximum .....................................................
2103 X X Dual Fuel System GLD – Natural gas and digester gas (500 – 650 BTU) (see Technical Data for ratings) –
Deletes standard fuel system. Customer must provide control for manual or automatic fuel changeover.
Adds main adjustment screws (MAS), one per fuel. Adds two gas carburetors, one Fisher 66Z regulator for
natural gas, one 2” NPT flexible connection (shipped loose) and one 2.5” NPT CP Maxon gas solenoid
valve (shipped loose). Natural gas fuel pressure – 20” H2O minimum and 5 PSIG maximum. Adds one
Fisher 66Z regulator for digester gas (shipped loose), one 2.5” NPT flexible connection (shipped loose) and
one 2.5”-125 lb flanged Maxon gas solenoid valve (shipped loose). See Power Rating chart for ratings.
Digester fuel pressure 25” H2O minimum and 5 PSIG maximum...................................................................
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. July 2022
PAGE GS VGF-11
H24
P48
F18
L36
Code MODEL VGF F18, H24, L36, P48 ACCESSORIES
2104 X X Dual Fuel System GLD – Natural gas and digester gas (500 – 650 BTU) (see Technical Data for ratings) –
Deletes standard fuel system. Customer must provide control for manual or automatic fuel changeover.
Adds main adjustment screws (MAS), one per fuel. Adds two gas carburetors, one Fisher 66Z regulator for
natural gas (shipped loose), one 3”-125 lb flanged flexible connection (shipped loose) and one 3” NPT
Maxon gas solenoid valve (shipped loose). Natural gas fuel pressure – 18” H2O minimum and 5 PSIG
maximum. Adds one Fisher 66Z regulator for digester gas (shipped loose), one 4”-125 lb flanged flexible
connection (shipped loose) and one 2.5”-125 lb flanged Maxon gas solenoid valve (shipped loose). See
Power Rating chart for ratings. Digester fuel pressure 18” H2O minimum and 5 PSIG maximum ...............
2105 X X Dual Fuel System GLD – Natural gas and landfill gas (400 – 500 BTU) (see Technical Data for ratings) –
Deletes standard fuel system. Customer must provide control for manual or automatic fuel changeover.
Adds main adjustment screws (MAS), one per fuel. Adds two gas carburetors, one Fisher 66Z regulator for
natural gas, one 2” NPT flexible connection (shipped loose) and one 2.5” NPT CP Maxon gas solenoid
valve (shipped loose). Natural gas fuel pressure – 20” H2O minimum and 5 PSIG maximum. Adds one
Fisher 66Z regulator for landfill gas (shipped loose), one 2.5” NPT flexible connection (shipped loose) and
one 2.5”-125 lb flanged Maxon gas solenoid valve (shipped loose). See Power Rating chart for ratings.
Digester fuel pressure 25” H2O minimum and 5 PSIG maximum...................................................................
2106 X X Dual Fuel System GLD – Natural gas and landfill gas (400 – 500 BTU) (see Technical Data for ratings) –
Deletes standard fuel system. Customer must provide control for manual or automatic fuel changeover.
Adds main adjustment screws (MAS), one per fuel. Adds two gas carburetors, one Fisher 66Z regulator for
natural gas (shipped loose), one 3”-125 lb flanged flexible connection (shipped loose) and one 3” NPT
Maxon gas solenoid valve (shipped loose). Natural gas fuel pressure – 18” H2O minimum and 5 PSIG
maximum. Adds one Fisher 66Z regulator for digester gas (shipped loose), one 4”-125 lb flanged flexible
connection (shipped loose) and one 2.5”-125 lb flanged Maxon gas solenoid valve (shipped loose). See
Power Rating chart for ratings. Digester fuel pressure 18” H2O minimum and 5 PSIG maximum ...............
ELECTRICAL SYSTEM
Generator Options:
3046 X X X X Cross Current Compensation – For reactive load control when parallel operation is required. Current
transformer included (shipped loose) (Not Required with ECP8000 Panel) ...............................................
3068 X X X X Winding Temperature and Generator Bearing Temperature Detector – 100 ohm platinum resistive
temperature detector (RTD), with a temperature coefficient of 0.00385 ohms/ohm/° C, one per phase,
total of three, and one bearing. ....................................................................................................................
Engine Options:
3433E X X Alternator – Denso, 24V DC, 50 amp, brushless, belt driven. Crankshaft pulley Code 8107 and drive belts are
included. Alternator system meets CSA Class I, Division 2, Group A, B, C & D (Canada & US) hazardous
location requirements ......................................................................................................................................
COOLING SYSTEM
4021 X X Jacket Water Heater – For ambients down to 40° F (4° C) Thermally controlled, with disconnect relay. Wired
to AC junction box. 2500 watt, 120V AC, 50/60 Hz, single phase. Mounted ..............................................
X X Jacket Water Heater – For ambients down to 40° F (4° C) Thermally controlled, with disconnect relay.
4023 Wired to AC junction box. 2500 watt, 240V AC, 50/60 Hz, single phase. Mounted ....................................
4024 X X Jacket Water Heater – Thermally controlled, with disconnect relay. Wired to AC junction box. 9000 watt,
230V AC, 50/60 Hz, or 7360W, 208V AC, 60 Hz, single phase. Mounted ..................................................
4287 X X High Temperature Thermostats: Omits standard thermostats and adds high temperature thermostats for
operation up to 210° F (99° C). Recommended for Digester/Landfill fuel systems. Consult the Application
Engineering Department for recommendation on jacket water temperature requirements before ordering
this Code. For water connect units only. .......................................................................................................
4287A X X High Temperature Thermostats: Omits standard thermostats and adds high temperature thermostats for
operation up to 210° F (99° C). Recommended for Digester/Landfill fuel systems. Consult the Application
Engineering Department for recommendation on jacket water temperature requirements before ordering
this Code. For water connect units only ........................................................................................................
4300 X X X X Flexible Water Connections for Solid Mounted Water Connect Units – Includes 2 jacket water, and 2
auxiliary water stainless steel flexes. (Shipped loose) .................................................................................
4300A X X X X Flexible Water Connections for Isolator Mounted Water Connect Units – Includes 2 jacket water, and 2
auxiliary water stainless steel flexes. (Shipped loose) .................................................................................
4650A X X X X Low Water Level Gauge and Safety Sensor Switch. Mounted on Radiator (jacket and auxiliary circuit). ....
4660A X X Removal of unit mounted radiator to meet customer’s shipping requirements...............................................
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. July 2022
PAGE GS VGF-12
H24
P48
F18
L36
Code MODEL VGF F18, H24, L36, P48 ACCESSORIES
LUBRICATION SYSTEM
5001A X X Lube Oil Heater/Prelube Pump – 2,500 watt heating element with electric circulating pump.
Thermostatically controlled (100° F on 120° F off). Designed for indoor duty. 120V. AC, single phase,
50/60 Hz. Continuous prelube not available. Customer supplied logic is required. Shipped loose ........
X X
5001B Lube Oil Heater/Prelube Pump – 2,500 watt heating element with electric circulating pump.
Thermostatically controlled (100° F on 120° F off). Designed for indoor duty. 208-240V AC, single phase,
50/60 Hz. Continuous prelube not available. Customer supplied logic is required. Shipped loose. .........
5001C X X Lube Oil Heater/Prelube Pump – 2,500 watt heating element with electric circulating pump.
Thermostatically controlled (100° F on 120° F off). Engine mounted. Designed for indoor duty. 230V AC,
single phase, 50/60 Hz. Continuous prelube not available. Customer supplied logic is required. Replace
standard prelube pump. (Mounted).. ...........................................................................................................................
5050A X X Prelube Pump – Mounted on a separate base, designed for indoor duty. Continuous prelube not available.
Customer supplied logic is required. Pump motor: 120V AC, single phase, 50/60 Hz. Shipped loose.
Customer supplied logic is required. ...........................................................................................................
5050B X X Prelube Pump – Mounted on a separate base, designed for indoor duty. Continuous prelube not available.
Customer supplied logic is required. Pump motor: 208-240V AC, single phase, 50/60 Hz. Shipped loose.
Customer supplied logic is required. ...........................................................................................................
5055 X X Mounting of Codes 5000, 5050, 5203 or 5205 series. .......................................................................................
5112 X X Waukesha Microspin* Oil Filtration System – Includes three cleanable full flow filter elements Microspin*
centrifugal bypass oil filter, shutoff valve and special crankcase door for oil return line. All components
shipped loose for customer mounting. Oil inlet and return lines are customer supplied per specific
application. Reference Service bulletin 12–2698D or latest edition for installation information .................
5112A X X Waukesha Microspin* Oil Filtration System – Includes mounted Microspin* centrifugal bypass oil filter with
shutoff valve ...................................................................................................................................................
5200 X X Lubrication Oil Level Regulator - Kenco...........................................................................................................
5200A X X Lubrication Oil Level Regulator – Kenco ..........................................................................................................
5201 X X Lubrication Oil Level Regulator - Kenco with totalizing flow meter. (Unit readout in gallons.) .......................
5201A X X Lubrication Oil Level Regulator - Kenco with totalizing flow meter. (Unit readout in gallons.) .......................
5201C X X Lubrication Oil Level Regulator - Kenco with totalizing flow meter. (Unit readout in liters.) ...........................
5201E X X Lubrication Oil Level Regulator - Kenco with totalizing flow meter. (Unit readout in liters.) ...........................
CONTROL SYSTEM
6020D X X X X Governor – Woodward 2301E digital load sharing system. For isochronous parallel operation of multiple units or
single unit stand alone or in parallel with utility. Metering transformers are not included. Meets Canadian
Standards Association non-hazardous (ordinary) location requirements. (Shipped loose.) (Not Required
with ECP8000 Panel)......................................................................................................................................................
6107 X X X X Maximum Throttle Indicator – Adds a switch that closes when the throttle is in the maximum throttle position.
Detects low power situations. See switchgear Code 6231 for shutdown logic ...............................................
6109B X X X X Oil level switch – High & low level shutdown ...................................................................................................
6109C X X X X Low lube oil level warning switch, Requires Code 5200, 5200A, 5201, 5201A, 5201C, and 5201E ...........
6189 X X X X Hourmeter/Tachometer – Digital electronic. mounted in engine instrument panel. Includes magnetic pickup. ...
6190 X X X X Magnetic pickup unit, extra, for customer use. ................................................................................................
6192A X Exhaust Thermocouples, Type K, (8 total), individual cylinders plus pre and post turbine. Wired to engine
mounted junction box ....................................................................................................................................
6192B X Exhaust Thermocouples, Type K, (10 total), individual cylinders plus pre and post turbine. Wired to engine
mounted junction box ....................................................................................................................................
6192C X Exhaust Thermocouples, Type K, (15 total), individual cylinders plus (2) pre turbine and (1) post turbine.
Wired to engine mounted junction box .........................................................................................................
6192D X Exhaust Thermocouples, Type K, (19 total), individual cylinders plus (2) pre turbine and (1) post turbine.
Wired to engine mounted junction box .........................................................................................................
6201A X X Pressure senders with 4-20 mA output. Includes mounting and wiring to a junction box of lube oil, intake
manifold, jacket water and fuel pressure transmitters ..................................................................................
6201B X X Pressure senders with 4-20 mA output. Includes mounting and wiring to a junction box of lube oil, intake
manifold, jacket water and fuel pressure transmitters ..................................................................................
6202 X X X X Type K temperature senders. Includes mounting and wiring jacket water outlet, lube oil inlet, intake
manifold, auxiliary water inlet and fuel gas thermocouples..........................................................................
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. July 2022
PAGE GS VGF-13
H24
P48
F18
L36
Code MODEL VGF F18, H24, L36, P48 ACCESSORIES
LINE CIRCUIT BREAKER – Molded case type thermal long time trip characteristic (ambient compensated)
with magnetic instantaneous trip characteristics with shunt trip and with auxiliary (A & B) contacts.
Generator mounted and cabled for customer power connections. (Circuit breaker rating should exceed
full load rating by 10%.)
6951 X X Adjustable Trip Circuit Breaker (400 / 500 / 600 / 800 Amp) ..........................................................................
6952 X Adjustable Trip Circuit Breaker (600 / 800 / 1000 / 1200 Amp) ......................................................................
6953 X Adjustable Trip Circuit Breaker (1000 / 1200 / 1400 / 1600/ 1700/ 1800/ 1900/ 2000 Amp) ........................
EXHAUST SYSTEM
Silencer – Residential ratings – (Shipped loose)
Note: Sizing is at standard kW ratings. Operation at non–standard ratings will affect silencer requirements.
Exhaust system back pressure calculations must be made for all applications. Contact factory for further
information.
7006A X Exhaust Silencer – GL/GLD/GSID. 1800/1500 rpm. Size 8″ flanged, end inlet, end outlet ...........................
7007 X Exhaust Silencer – GL/GLD/GSID. 1800/1500 rpm. Size 10″ flanged, end inlet, end outlet .........................
7008A X Exhaust Silencer – GL/GLD/GSID. 1800/1500 rpm. Size 12″ flanged, end inlet, end outlet .........................
7009 X Exhaust Silencer – GL/GLD/GSID. 1800/1500 rpm. Size 14″ flanged, end inlet, end outlet .........................
STARTING SYSTEM
9050 X X X X Battery Box – High density polyurethane construction with a protective cover. Holds batteries, Batteries
not included. Shipped loose ..........................................................................................................................
9110 X X Starter – Low Pressure Air or Gas, TDI T312, inertia engaged, mounted, with strainer and valve. Minimum
pressure 30 psi (3.5 Kg/cm2) above 50° F (10° C). Maximum pressure 60 psi (10.5 Kg/cm2). For remote
control with 24V DC start valve including manual override. Deletes standard electric start. ......................
9110A X X Starter – High Pressure Air or Gas, TDI T306, inertia engaged, mounted, with strainer and valve. Minimum
pressure 60 psi (3.5 Kg/cm2) above 50° F (10° C). Maximum pressure 120 psi (10.5 Kg/cm2). For remote
control with 24V DC start valve including manual override. Deletes standard electric start. ......................
9110B X X Starter – Low Pressure Air or Gas, TDI T112, inertia engaged, mounted, with strainer and valve. Minimum
pressure 50 psi (3.5 Kg/cm2) above 50° F (10° C). Maximum pressure 90 psi (10.5 Kg/cm2). For remote
control with 24V DC start valve including manual override. Deletes standard electric start. ......................
9110C X X Starter – High Pressure Air or Gas , TDI T106, inertia engaged, mounted, with strainer and valve. Minimum
pressure 90 psi (3.5 Kg/cm2) above 50°F (10°C). Maximum pressure 150 psi (10.5 Kg/cm2). For remote
control with 24V DC start valve including manual override. Deletes standard electric start. Includes flex
air supply connection for starting air. ............................................................................................................
9300 X X X X Flexible Air Starter Supply Connection for Solid or Isolator Mounted Units – Includes 1 stainless steel flex.
(Shipped loose) ..............................................................................................................................................
BASES
9511A X X Vibration Isolators – Spring Type. Requires a longer than standard exhaust flex connection (not supplied).
(Shipped loose. For seismic zone applications other than Zone 0, contact Application Engineering) ......
9511B X X Vibration Isolators – Spring Type. Requires a longer than standard exhaust flex connection (not supplied).
(Shipped loose. For seismic zone applications other than Zone 0, contact Application Engineering) ......
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. July 2022
PAGE GS VGF-14
H24
P48
F18
L36
Code MODEL VGF F18, H24, L36, P48 ACCESSORIES
MISCELLANEOUS
9974Q X X X X Engine/Enginator that is Customs Union Compliant (Russia, Belarus, and Kazakhstan). Includes SERIAL
NUMBER SPECIFIC Technical Passport & Safety Justification in Russian and English, Engine
Operator's Manuals (one in Russian and one in English), and EAC label on unit. Enginators include
supplied equipment manuals that are in English only. May require additional lead time, consult factory
for delivery information ..................................................................................................................................
9974V X X X X Enginator that is CE Mark Compliant. Includes CE Mark Label, the following documentation in both English
and language of country of final installation, order to state required language; SERIAL NUMBER
SPECIFIC Declaration of Conformance, Operator, Generator and Voltage Regulator Manuals. All other
supporting documentation is supplied in English only. Contact Applications/Sales if the sale requires
additional translation requirements. May require additional lead time and cost, consult factory for delivery
information. ....................................................................................................................................................
9974W X X X X Required label for Hazardous Location CSA Certification in US & Canada end use. Adds a safety label
containing English and French language that is required to comply with the certification terms of the
equipment. For use with code 3314A. Note: For end uses classified as Hazardous Locations Division 2
and in US & Canada. Contact Application Engineering for use in other countries. ....................................
9990 X X X X Paint – Waukesha standard paint quality to match customer supplied paint chip.
Requires FED-STD-595B or 595C ................................................................................................................
EXTENDED WARRANTY
10012AA X 6-Cylinder VGF Genset Extended Warranty -- 1 Year. Extended warranty excludes wear items and
includes only warrantable items as defined in Express Limited Warranty (ELW). Must be purchased at
time of original order. If applicable, the proper deferral process and preservation as outlined in Service
Bulletin 16-1855H (or most current) and WEDA 542 (or most current) must be followed or warranty
extension is void. ...........................................................................................................................................
10012BB X 6-Cylinder VGF Genset Extended Warranty -- 2 Years. Extended warranty excludes wear items and
includes only warrantable items as defined in Express Limited Warranty (ELW). Must be purchased at
time of original order. If applicable, the proper deferral process and preservation as outlined in Service
Bulletin 16-1855H (or most current) and WEDA 542 (or most current) must be followed or warranty
extension is void. ...........................................................................................................................................
10012CC X 6-Cylinder VGF Genset Extended Warranty -- 3 Years. Extended warranty excludes wear items and
includes only warrantable items as defined in Express Limited Warranty (ELW). Must be purchased at
time of original order. If applicable, the proper deferral process and preservation as outlined in Service
Bulletin 16-1855H (or most current) and WEDA 542 (or most current) must be followed or warranty
extension is void. ...........................................................................................................................................
10013AA X 8-Cylinder VGF Genset Extended Warranty -- 1 Year. Extended warranty excludes wear items and
includes only warrantable items as defined in Express Limited Warranty (ELW). Must be purchased at
time of original order. If applicable, the proper deferral process and preservation as outlined in Service
Bulletin 16-1855H (or most current) and WEDA 542 (or most current) must be followed or warranty
extension is void. ...........................................................................................................................................
10013BB X 8-Cylinder VGF Genset Extended Warranty -- 2 Years. Extended warranty excludes wear items and
includes only warrantable items as defined in Express Limited Warranty (ELW). Must be purchased at
time of original order. If applicable, the proper deferral process and preservation as outlined in Service
Bulletin 16-1855H (or most current) and WEDA 542 (or most current) must be followed or warranty
extension is void. ...........................................................................................................................................
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. July 2022
PAGE GS VGF-15
H24
P48
F18
L36
Code MODEL VGF F18, H24, L36, P48 ACCESSORIES
10013CC X 8-Cylinder VGF Genset Extended Warranty -- 3 Years. Extended warranty excludes wear items and
includes only warrantable items as defined in Express Limited Warranty (ELW). Must be purchased at
time of original order. If applicable, the proper deferral process and preservation as outlined in Service
Bulletin 16-1855H (or most current) and WEDA 542 (or most current) must be followed or warranty
extension is void. ...........................................................................................................................................
10014AA X 12-Cylinder VGF Genset Extended Warranty -- 1 Year. Extended warranty excludes wear items and
includes only warrantable items as defined in Express Limited Warranty (ELW). Must be purchased at
time of original order. If applicable, the proper deferral process and preservation as outlined in Service
Bulletin 16-1855H (or most current) and WEDA 542 (or most current) must be followed or warranty
extension is void. ...........................................................................................................................................
10014BB X 12-Cylinder VGF Genset Extended Warranty -- 2 Years. Extended warranty excludes wear items and
includes only warrantable items as defined in Express Limited Warranty (ELW). Must be purchased at
time of original order. If applicable, the proper deferral process and preservation as outlined in Service
Bulletin 16-1855H (or most current) and WEDA 542 (or most current) must be followed or warranty
extension is void. ..........................................................................................................................................
10014CC X 12-Cylinder VGF Genset Extended Warranty -- 3 Years. Extended warranty excludes wear items and
includes only warrantable items as defined in Express Limited Warranty (ELW). Must be purchased at
time of original order. If applicable, the proper deferral process and preservation as outlined in Service
Bulletin 16-1855H (or most current) and WEDA 542 (or most current) must be followed or warranty
extension is void. ...........................................................................................................................................
10015AA X 16-Cylinder VGF Genset Extended Warranty -- 1 Year. Extended warranty excludes wear items and
includes only warrantable items as defined in Express Limited Warranty (ELW). Must be purchased at
time of original order. If applicable, the proper deferral process and preservation as outlined in Service
Bulletin 16-1855H (or most current) and WEDA 542 (or most current) must be followed or warranty
extension is void. ...........................................................................................................................................
10015BB X 16-Cylinder VGF Genset Extended Warranty -- 2 Years. Extended warranty excludes wear items and
includes only warrantable items as defined in Express Limited Warranty (ELW). Must be purchased at
time of original order. If applicable, the proper deferral process and preservation as outlined in Service
Bulletin 16-1855H (or most current) and WEDA 542 (or most current) must be followed or warranty
extension is void. ...........................................................................................................................................
10015CC X 16-Cylinder VGF Genset Extended Warranty -- 3 Years. Extended warranty excludes wear items and
includes only warrantable items as defined in Express Limited Warranty (ELW). Must be purchased at
time of original order. If applicable, the proper deferral process and preservation as outlined in Service
Bulletin 16-1855H (or most current) and WEDA 542 (or most current) must be followed or warranty
extension is void. ...........................................................................................................................................
DISCLAIMER
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. July 2022
PAGE CPS-1
Control Panels
MODEL APPLICABILITY LIST PRICE (JUNE 2022)
ECP8000-ESM2 Enginators with ESM2 controls (on-skid, mounted panel) Included with ESM2 Enginators
ECP8000-ESM1 Enginators with ESM1 controls (loose, free-standing panel)
ECP8000 Enginators with CEC controls (loose, free-standing panel)
Switchgear
MODEL APPLICABILITY* LIST PRICE (JUNE 2022)
LV800 800A Low Voltage Switchgear for Enginators
LV1600 1600A Low Voltage Switchgear for Enginators
LV2500 2500A Low Voltage Switchgear for Enginators
LV3000 3000A Low Voltage Switchgear for Enginators
MV3300 3.3kV Medium Voltage Switchgear for Enginators
MV4160 4.16kV Medium Voltage Switchgear for Enginators
MV6600 6.6kV Medium Voltage Switchgear for Enginators
MV11000 11kV Medium Voltage Switchgear for Enginators
MV13800 13.8kV Medium Voltage Switchgear for Enginators
*Contact Waukesha Application Engineering for sizing support if needed. Low voltage switchgear selection is dependent on unit rating. Medium
voltage switchgear selection is dependent upon Enginator voltage level.
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted US Dollars. June 2022
PAGE CPS-2
MODEL ECP8000-ESM2
ENGINATOR* CONTROL SYSTEM
FOR SINGLE OR MULTIPLE UNITS IN PARALLEL
The ECP8000-ESM2 system consists of one genset-mounted control panel for controlling single stand alone, multiple units in parallel, or utility
paralleling applications. The panel is IP65 (NEMA 4) rated for outdoor use, with the following dimensions: 1219mmH x 610mmW x 274mmD (48”H x
24”W x 10.8”D). Operating temperature -20°C to +70°C (-4°F to +158°F), relative humidity 0-95% (non-condensing).
The ECP8000-ESM2 system is pre-wired and mounted on-skid, next to the generator. The mounted panel contains input/output modules connected
to Enginator sensors and the ESM2 control system with harnesses. Inputs are provided to read all (standard and optional) sensors ordered with the
Enginator. In addition, warnings and shutdowns typically associated with the sensors are provided.
The ECP8000-ESM2 is based on the ComAp InteliSys-NTC genset controller, and provides a multitude of genset control functions, including:
start/stop, pre/post lube, engine protections, synchronizing, CB control, kW and power factor control, protective relaying, load shedding, auto
start/stop based on plant load or loss of utility, engine run hour balancing, etc. In addition, the ECP8000-ESM2 reads the engine Modbus stream to
display and log engine as well as generator data. The 12-inch ESM2 engine display panel is used to display and log both engine and genset
information and controls. The InteliSys-NTC base unit, voltage regulator, terminal blocks and other control components are mounted inside.
BASIC COMPONENTS
ALARM HORN – Sounded on any shutdown or warning signal. PROTECTIVE FUNCTIONS - Generator
Adjustable volume level.
A. #27 Under-voltage, 3 phase
CONTROLS – ComAp InteliSys-NTC genset controller based.
B. #32 Reverse Power
www.comap.cz for more detailed information.
C. #46 Current Unbalance
EMERGENCY STOP SWITCH – Local and remote
D. #47 Voltage Unbalance
ENGINATOR CONTROL – Includes (but not limited to):
E. #50/51 Phase Overcurrent
• Up to 32 units paralleled in island mode (kW/kVAR
sharing) F. #59 Over-voltage, 3 phase
• Utility paralleling (fixed kW and power factor) G. #81O/U Over/Underfrequency
• Reads ESM Modbus and displays/records engine data PROTECTIVE FUNCTIONS – Utility/Bus
• Engine and Generator protections A. #27 Under-voltage, 3 phase
• Remote start/stop and load setpoint
B. #47 Voltage Unbalance
• Start/Stop units based on site load
• Auto Standby Start based on Utility mains failure C. #59 Over-voltage, 3 phase
• Automatic synchronizer D. #78 Vector Shift
• Soft loading/unloading E. #81O/U Over/Underfrequency
• Load shedding
PROTECTIVE FUNCTIONS – Engine
• Built-in PLC functionality, including PID loops, available for
custom logic. • All optional warning/shutdown sensors ordered with the
• Analog and digital extension modules to expand I/O Enginator.
CIRCUIT BREAKER CONTROL – Controls opening and closing of an MODBUS – Serial (RS232) and TCP/IP (Ethernet) ports for customer
external, electrically operated generator circuit breaker. SCADA access to all genset parameters. May also be used for
HUMAN MACHINE INTERFACE (HMI) – 12” ESM2 resistive touch remote control.
color display with user-friendly controls. Access to all controller SOFTWARE – Configuration, programming, and monitoring software
setpoints, with multiple user access levels and protection. Includes may be downloaded for free at www.comap-control.com/
fault information viewing and continuous data logging capability over TERMINAL BLOCKS – Spring-cage style.
the lifetime of the product. On-screen E-Help troubleshooting TESTING – Panels are fully tested with the Enginator.
information for all engine ESM2 faults, and technical documentation
VOLTAGE REGULATOR – Mounted and wired.
such as manuals and service bulletins. Connect an additional HMI
(not included) for remote viewing and control. PAINT – Standard is ANSI–61 gray.
INTEGRATED AC Metering – Monitors many generator AC DOCUMENTATION – The following items are supplied as standard
parameters (current, frequency, voltage, power, power factor) and with every order:
generator bus synchronizing information. 2% accuracy. – Electronic notification and access to drawings for review and or
LOGGING – Records all vital Enginator parameters every 5 minutes approval.
while the unit is running. Logs alarms and does a fast data capture – One Enginator* Control panel manual consisting of:
of the parameters in the seconds leading up to the event. Logs are Instructions on major items
time and date stamped.
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted US Dollars. June 2022
PAGE CPS-3
MODEL ECP8000-ESM1
ENGINATOR* CONTROL SYSTEM
FOR SINGLE OR MULTIPLE UNITS IN PARALLEL
The ECP8000-ESM1 system consists of one free-standing control panel for controlling single stand alone, multiple units in parallel, or utility
paralleling applications. The panel is IP 52 (NEMA 12) rated for indoor use, with dimensions: 1830mmH x 764mmW x 459mmD (72”H x 30”W x
18”D).. Operating temperature -20°C to +70°C (-4°F to +158°F), relative humidity 0-95% (non-condensing).
Wiring between the Enginator and panel is done using standard interface harnesses and/or customer wiring. Inputs are provided to read all
(standard and optional) sensors ordered with the Enginator. In addition, warnings and shutdowns typically associated with the sensors are provided.
The ECP8000-ESM1 is based on the ComAp InteliSys-NTC genset controller, and provides a multitude of genset control functions, including:
start/stop, pre/post lube, engine protections, synchronizing, CB control, kW and power factor control, protective relaying, load shedding, auto
start/stop based on plant load or loss of utility, engine run hour balancing, etc. In addition, the ECP8000 reads the ESM Modbus stream in order to
display and log engine as well as generator data. An 8-inch color HMI (Human Machine Interface), Emergency stop switch, indicating lights, and
alarm horn are mounted on the front door. Any additional HMI for the engine control system (e.g. AFRv2) is also mounted on the front door. The
InteliSys-NTC base unit, voltage regulator, terminal blocks and other control components are mounted inside.
BASIC COMPONENTS
ALARM HORN – Sounded on any shutdown or warning signal. PROTECTIVE FUNCTIONS - Generator
Adjustable volume level.
H. #27 Under-voltage, 3 phase
CONTROLS – ComAp InteliSys-NTC genset controller based.
I. #32 Reverse Power
www.comap.cz for more detailed information.
J. #46 Current Unbalance
EMERGENCY STOP SWITCH – Local and remote
K. #47 Voltage Unbalance
ENGINATOR CONTROL – Includes (but not limited to):
L. #50/51 Phase Overcurrent
• Up to 32 units paralleled in island mode (kW/kVAR
sharing) M. #59 Over-voltage, 3 phase
• Utility paralleling (fixed kW and power factor) N. #81O/U Over/Underfrequency
• Reads ESM Modbus and displays/records engine data PROTECTIVE FUNCTIONS – Utility/Bus
• Engine and Generator protections F. #27 Under-voltage, 3 phase
• Remote start/stop and load setpoint
G. #47 Voltage Unbalance
• Start/Stop units based on site load
• Auto Standby Start based on Utility mains failure H. #59 Over-voltage, 3 phase
• Automatic synchronizer I. #78 Vector Shift
• Soft loading/unloading J. #81O/U Over/Underfrequency
• Load shedding
PROTECTIVE FUNCTIONS – Engine
• Built-in PLC functionality, including PID loops, available for
custom logic. • All optional warning/shutdown sensors ordered with the
• Analog and digital extension modules to expand I/O Enginator.
CIRCUIT BREAKER CONTROL – Controls opening and closing of an MODBUS – Serial (RS232) and TCP/IP (Ethernet) ports for customer
external, electrically operated generator circuit breaker. SCADA access to all genset parameters. May also be used for
remote control.
GOVERNOR – Electronic controller is mounted and wired (non-ESM
Enginators). SOFTWARE – Configuration, programming, and monitoring software
HUMAN MACHINE INTERFACE (HMI) – 8” TFT color display with may be downloaded for free at www.comap-control.com/
user-friendly controls. Access to all controller setpoints, with 7 levels TERMINAL BLOCKS – Spring-cage style.
of password protection. Real-time trending of all parameters. The TESTING – Panels are fully tested with the Enginator.
display is capable of displaying multiple language translations VOLTAGE REGULATOR – Mounted and wired.
including graphical languages (e.g. Chinese). Connect an additional
PAINT – Standard is ANSI–61 gray.
HMI (not included) for remote viewing and control.
DOCUMENTATION – The following items are supplied as standard
INTEGRATED AC Metering – Monitors many generator AC
with every order:
parameters (current, frequency, voltage, power, power factor) and
generator bus synchronizing information. 2% accuracy. – Electronic notification and access to drawings for review and or
LOGGING – Records all vital Enginator parameters every 5 minutes approval.
while the unit is running. Logs alarms and does a fast data capture – One Enginator* Control panel manual consisting of:
of the parameters in the seconds leading up to the event. Logs are Instructions on major items
time and date stamped.
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted US Dollars. June 2022
PAGE CPS-4
MODEL ECP8000
ENGINATOR* CONTROL SYSTEM
FOR SINGLE OR MULTIPLE UNITS IN PARALLEL
The ECP8000 system consists of one free-standing control panel for controlling single stand alone, multiple units in parallel, or utility paralleling
applications. The panel is IP 52 (NEMA 12) rated for indoor use, with dimensions: 1830mmH x 764mmW x 459mmD (72”H x 30”W x 18”D)..
Operating temperature -20°C to +70°C (-4°F to +158°F), relative humidity 0-95% (non-condensing).
Wiring between the Enginator and panel is done using standard interface harnesses and/or customer wiring. Inputs are provided to read all
(standard and optional) sensors ordered with the Enginator. In addition, warnings and shutdowns typically associated with the sensors are provided.
The ECP8000 is based on the ComAp InteliSys-NTC genset controller, and provides a multitude of genset control functions, including: start/stop,
pre/post lube, engine protections, synchronizing, CB control, kW and power factor control, protective relaying, load shedding, auto start/stop based
on plant load or loss of utility, engine run hour balancing, etc. In addition, the ECP8000 reads the engine sensors in order to display and log engine
as well as generator data. An 8-inch color HMI (Human Machine Interface), Emergency stop switch, indicating lights, and alarm horn are mounted on
the front door. The InteliSys-NTC base unit, voltage regulator, terminal blocks and other control components are mounted inside. The electronic
governor controller is also mounted inside.
BASIC COMPONENTS
ALARM HORN – Sounded on any shutdown or warning signal. PROTECTIVE FUNCTIONS - Generator
Adjustable volume level.
O. #27 Under-voltage, 3 phase
CONTROLS – ComAp InteliSys-NTC genset controller based.
P. #32 Reverse Power
www.comap.cz for more detailed information.
Q. #46 Current Unbalance
EMERGENCY STOP SWITCH – Local and remote
R. #47 Voltage Unbalance
ENGINATOR CONTROL – Includes (but not limited to):
S. #50/51 Phase Overcurrent
• Up to 32 units paralleled in island mode (kW/kVAR
sharing) T. #59 Over-voltage, 3 phase
• Utility paralleling (fixed kW and power factor) U. #81O/U Over/Underfrequency
• Reads ESM Modbus and displays/records engine data PROTECTIVE FUNCTIONS – Utility/Bus
• Engine and Generator protections K. #27 Under-voltage, 3 phase
• Remote start/stop and load setpoint
L. #47 Voltage Unbalance
• Start/Stop units based on site load
• Auto Standby Start based on Utility mains failure M. #59 Over-voltage, 3 phase
• Automatic synchronizer N. #78 Vector Shift
• Soft loading/unloading O. #81O/U Over/Underfrequency
• Load shedding
PROTECTIVE FUNCTIONS – Engine
• Built-in PLC functionality, including PID loops, available for
custom logic. • All optional warning/shutdown sensors ordered with the
• Analog and digital extension modules to expand I/O Enginator.
CIRCUIT BREAKER CONTROL – Controls opening and closing of an MODBUS – Serial (RS232) and TCP/IP (Ethernet) ports for customer
external, electrically operated generator circuit breaker. SCADA access to all genset parameters. May also be used for
remote control.
GOVERNOR – Electronic controller is mounted and wired (non-ESM
Enginators). SOFTWARE – Configuration, programming, and monitoring software
HUMAN MACHINE INTERFACE (HMI) – 8” TFT color display with may be downloaded for free at www.comap-control.com/
user-friendly controls. Access to all controller setpoints, with 7 levels TERMINAL BLOCKS – Spring-cage style.
of password protection. Real-time trending of all parameters. The TESTING – Panels are fully tested with the Enginator.
display is capable of displaying multiple language translations VOLTAGE REGULATOR – Mounted and wired.
including graphical languages (e.g. Chinese). Connect an additional
PAINT – Standard is ANSI–61 gray.
HMI (not included) for remote viewing and control.
DOCUMENTATION – The following items are supplied as standard
INTEGRATED AC Metering – Monitors many generator AC
with every order:
parameters (current, frequency, voltage, power, power factor) and
generator bus synchronizing information. 2% accuracy. – Electronic notification and access to drawings for review and or
LOGGING – Records all vital Enginator parameters every 5 minutes approval.
while the unit is running. Logs alarms and does a fast data capture – One Enginator* Control panel manual consisting of:
of the parameters in the seconds leading up to the event. Logs are Instructions on major items
time and date stamped.
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted US Dollars. June 2022
PAGE CPS-5
The Low Voltage Switchgear is a freestanding 3 phase, 4 wire unit for a single genset. The enclosure is IP 10 (NEMA 1) rated with approximate
dimensions: 660mm W x 1003mm D x 2032mm H (26”W x 39 1/2”D x 80”H) for indoor use, with top or bottom cable entry. Standard operating
temperature 10°C to 40°C (50°F to 104°F). UL891 listed and labeled for continuous duty.
Supplied breakers are 3 pole LSIG type, 100% rated, draw-out, and electrically operated. Control power is 24VDC customer supplied. Top or bottom
cable entry. Unit comes fully assembled with only external circuit connections required. Horizontal bussing (with 100% neutral) is standard including
a splice kit to connect multiple switchgear sections together.
BASIC COMPONENTS
AMPERAGE RATING– Available at ratings of 800A, 1600A, 2500A, DOCUMENTATION – The following items are supplied as standard
or 3000A. Contact Waukesha Application Engineering for with every order:
appropriate sizing per Enginator model. – Electronic notification and access to drawings for review and or
BUS – Silver plated copper. Fully rated for entire width of the approval.
switchgear assembly. Fully rated bus splice kit to join multiple – One Enginator System manual consisting of:
sections of main horizontal bus.
• Instructions on major special items.
CONTROLS – 24VDC breaker control with additional connections for
bus voltage monitoring of each phase, status, ready-to-close, and
fault trip.
CIRCUIT BREAKER:
• Electrically operated with manual control pushbutton
backup.
• Draw-out type, with interlock to prevent withdrawal of circuit
breaker in closed position.
• Insulated case circuit breaker (ICCB) UL 489 or 1066 rated
• Interrupt rating of:
o 65 kA @ 480VAC for <2500A
o 100 kA @ 480VAC for >2500A
• Color-coded visual indication of contact open/closed and
mechanism charged/discharged positions.
ENCLOSURE – NEMA 1 (IP 10), vented, gray free standing steel unit
for general indoor use. Front hinged door with two lockable t-
handles. Top or bottom cable entry.
INSTRUMENTATION TRANSFORMERS – Neutral sensing only.
OUTPUT CONTACTS – contacts for status, ready-to-close, and fault-
trip.
PAINT – Standard is ANSI–61 gray powder coat.
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted US Dollars. June 2022
PAGE CPS-6
The Medium Voltage Switchgear is a freestanding 3 phase, 3 wire (no neutral) unit for a single genset. The enclosure is IP 10 (NEMA 1) rated with
approximate dimensions: 914mm W x 1715mm D x 2540mm (36”W x 67 1/2”D x 100”H) for indoor use, with top or bottom cable entry. Standard
operating temperature 10°C to 40°C (50°F to 104°F). Rated for continuous duty.
Supplied breakers are 3 pole LSIG type, 100% rated, draw-out, and electrically operated. Control power is 24VDC customer supplied. Top or bottom
cable entry. Unit comes fully assembled with only external circuit connections required. Horizontal bussing (with 100% neutral) is standard including
a splice kit to connect multiple switchgear sections together.
BASIC COMPONENTS
SYSTEM RATINGS ENCLOSURE – NEMA 1 (IP 10), vented, gray free standing steel unit
• Main bus Ampacity 3000A continuous, 25kA interrupt rating for general indoor use. Front hinged door with two lockable t-
(IR), 95kV basic impulse level (BIL), dual 50Hz/60Hz rated. handles. Top or bottom cable entry.
• System voltages available: 3.3kV, 4.16kV, 6.6kV, 11kV, INSTRUMENTATION TRANSFORMERS
13.8kV. Contact Waukesha Application Engineering for • Current Transformers (CTs): one set of three, open delta,
appropriate sizing per Enginator model. fixed mount (ratio depending on voltage selection)
BUS – Silver plated copper. Fully rated for entire width of the • Potential Transformers (PTs): two sets of three. One set
switchgear assembly. Fully rated bus splice kit to join multiple open delta fixed mount (generator line side). One set open
sections of main horizontal bus. delta, draw-out (main bus side)
CONTROLS – 24VDC breaker control with additional connections for OUTPUT CONTACTS – contacts for status, ready-to-close, and fault-
bus voltage monitoring of each phase, status, ready-to-close, and trip.
fault trip. PAINT – Standard is ANSI–61 gray powder coat.
CIRCUIT BREAKER: DOCUMENTATION – The following items are supplied as standard
• Electrically operated with manual backup. with every order:
• Draw-out type, CULUS listed, with interlock to prevent racking – Electronic notification and access to drawings for review and or
a closed circuit breaker to or from any position. approval.
• Vacuum type (VCB) – One Enginator System manual consisting of:
• 1200A max. rating. • Instructions on major special items
• Color-coded visual indication of contact open/closed and
mechanism charged/discharged positions.
• mechanism charged/discharged positions.
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted US Dollars. June 2022
PAGE CPS-7
MV SWITCHGEAR
LV SWITCHGEAR
CONTROLS
6018 X Load Sharing Dongle for multiple units in Island operation
Enables digital kW load sharing and VAR sharing. Start / Stop units based on kW demand.
Unit priority selected by operator or automatically based on engine hours. .............................
6270 X Analog load sharing Interface module which allows the ComAp controls to connect to an analog
load sharing system (ex. Woodward 0-3 VDC load sharing lines) ................................................
6302A X X X Battery Charger, 20 amp – Shipped Loose. Programmable with digital display. 90-265 VAC, 47-
63 Hz input, 24V DC output. For lead-acid, Absorbant Glass Mat (AGM), or Nickel-Cadmium
(NiCad) batteries. NEMA 1 enclosure for wall mounting.
Approvals: North America: cULus, NFPA, ABS, Seismic. CE: EMC, LVD, RoHS .....................
6303A X X X Battery Charger, 50 amp – Shipped Loose. Static, float/equalize type with DC ammeter and DC
voltmeter. 230V AC, 1 ph 50/60 Hz input, 24V DC output. For lead–acid batteries only. Supplied
in a NEMA enclosure for separate remote mounting ........................................................................
6996 X Utility Mains CB Controller ..............................................................................................................
Only required if control of the utility CB is desired. Shipped loose for installation in customer
supplied utility tie breaker panel. Contact factory if a Waukesha-supplied utility tie breaker
panel is needed. Includes the following features:
-Import / Export control
-Utility Mains CB control and synchronizing generator bus to utility
-Utility Mains electrical protections
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted US Dollars. June 2022
PAGE SS-1
Note: Up to three to seven days may be required to process after receipt of customer P.O.
SPECIFICATION PACKAGE
9972 Specification Package – Ordered with engine or unit. Limit one per engine. .......................................................................................
PRINT CLASSIFICATION
9988 Certified Engine Outline Drawings – Standard engine outline prints showing overall dimensions, mounting holes, and customer
connection location for basic price code engines and units. These drawings are certified dimensionally correct. Note: Non-
Certified Engine Outline Drawings can be found at https://www.innio.com/en/sign-in - Documents -Outline Drawings .
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. June 2022
PAGE SS-2
9975E VHP* F3524G, F3514GSI, F3524GSI with ESM* O&M Manual- (Form 6300) ...................................................................................
9975EE VHP* Series Four 6-Cylinder with ESM2 Operation & Maintenance – (Form 10066) ........................................................................
9975Q VHP* Series Four* 12 Cyl with ESM* and Extender Series* O&M Manual– Form (6387) ................................................................
9975QB VHP* Series Four 12-Cylinder with ESM2 Operation & Maintenance– (Form 10002) .......................................................................
9975QC VHP* Series Five 12-Cylinder with ESM2 Operation & Maintenance– (Form 10063) .......................................................................
9975X VHP 12 Cyl Drill Rig/EPA Mobile Certified Engine (Form 6384) .........................................................................................................
9975AA VGF* F18/H24SE EPA Certified – O&M Manual (Form 10041) ..........................................................................................................
9976D L36/P48 G/GSI/GSID/GL/GLD Repair & Overhaul Manual – (Form 6264) .........................................................................................
9976G L5108, L5790G, L7042 G/GSI/GL Repair & Overhaul Manual – (Form 6248) ...................................................................................
9976K L5774LT, L5794GSI, L5794LT, L7042GSI S4, L7044G and L7044GSI with ESM and Extender Series Repair & Overhaul
Manual – (Form 6320) ........................................................................................................................................................................
9976KK VHP* Series Four* L5794/7044GSI with EPA Mobile Certification and mobileFLEX Repair & Overhaul – (Form 6394) ................
9976KL VHP* Series Five Repail & Overhaul Manual – (Form 10064) ...........................................................................................................
9976MN VHP* P9394GSI S5 Repair & Overhaul Manual – (Form 10087) ........................................................................................................
9979B 12V/16V 275GL/GL+ ESM2 Repair & Overhaul Manual – (Form 10099) ...........................................................................................
PARTS CATALOG
9977C VGF* F18G/GSI/GSID/GL/GLD/H24G/GSI/GSID/GL/GLD Parts Catalog – (Form 6330) ................................................................
9977E VGF* L36GSI/GSID/GL/GLD/P48GSI/GSID/GL/GLD Parts Catalog – (Form 6260) .........................................................................
9977J VHP* Series Four* 6 Cylinder with ESM* Parts Catalog – (Form 6301) ............................................................................................
9977U VHP* Series Four* 12 Cylinder with ESM* and Extender Series* Parts Catalog – (Form 6315) ......................................................
9977NN VGF F18/H24SE with ESM* and AFR2/emPact Emissions Control System Parts Catalog – (Form 10015) ...................................
9977UU VHP* Series Four* 12 Cylinder with ESM*, Extender Series*, and AFR2/emPact Emission Control System Parts Catalog –
(Form 6390) ...........................................................................................................................................................................................
9977UV VHP* Series Four 12-Cylinder with ESM2 Parts Catalog - (Form 10073)...........................................................................................
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. June 2022
PAGE SS-3
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. June 2022
PAGE SS-4
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. June 2022
PAGE SS-5
DOCUMENTATION
Electronic notification and access to submittal drawings for review and/or approval.
Enginator manual (quantity 1 per Enginator *, shipped with Enginator*) consists of:
– Engine Operation/Service Manual
– Engine Parts Book
– Generator/Voltage Regulator Instruction Manuals
– Instructions on major special items
Engomatic* Control System manual (quantity 1 per panel, shipped with control system) consists of:
– Instructions on major special items
* Waukesha generated drawings dimensioned in standard English units.
ADDITIONAL ITEMS:
MM0050 Metric dimensioning of Waukesha generated drawings instead of standard English units .....................................................
MM0100 Each additional Enginator manual ............................................................................................................................................
Enginator manual prices listed are manuals ordered at time of unit order or for units which were shipped within the last two years.
MM0100A Enginator manual for units shipped over two years ago up to five years old ...........................................................................
Specific Enginator/identification numbers must be provided.
MM0101 Each additional Engomatic manual ............................................................................................................................................
MM0101A Engomatic manual for units shipped over two years ago up to five years old .........................................................................
Specific Engomatic/identification numbers must be provided.
STANDARD TESTING
Standard testing is done at Unity (1.0) Power Factor as follows:
Make all necessary adjustments. Start unit and run at no load for five minutes, during which time an audible and visual check is
to be made for abnormal noises, vibration, water, and oil leaks. Then increase load to 50% for minimum of fifteen minutes and
100% for minimum of thirty minutes. Near the end of each load run, read and record the following information:
– Time
– Ambient Air Temperature
– RPM
– Kilowatt Load
– A.C. Voltage of Generator (phase to phase)
– A.C. Amperes of Generator (line current to load)
– Frequency
– Jacket Water Temperature from Engine
– Lube Oil Temperature to Engine
– Lube Oil Pressure to Engine
– Intake Manifold Pressure
– Fuel Pressure to Carburetor (gas/air)
– Overspeed Trip Point
– Crankcase Pressure
– Lube Oil Pressure Switch Trip Points
– Jacket Water Temperature Switch Trip Points
– Trip Points of All Special Switches
– Make Recording Charts of Voltage and Frequency for Step Loads and Load Changes
– Record Barometer, Induction Air Temperature and Power Correction Factor. Only items specific to an order will be
recorded.
– All standard production or witness tests on radiator-cooled units will be tested without the radiator
After unit has been tested, all water and oil is drained.
All engines receive the following preservation good for one year:
– Fog intake manifolds with nucle oil
– After draining oil fog oil pan with nucle oil
– See Service Bulletins 16–1858 and 16–1855D for represervation beyond one year.
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. June 2022
PAGE SS-6
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. June 2022
PAGE SS-7
PROPRIETARY INFORMATION - KEEP CONFIDENTIAL. The manufacturer reserves the right to change prices, specifications and design at any time without notice, and
without incurring obligation. All prices quoted U.S. Dollars. June 2022
© 2022 INNIO Waukesha gas engines. Information provided is subject to change without notice. All values are design or typical values when measured under laboratory conditions.