DFE 3 118 (2003) Manual
DFE 3 118 (2003) Manual
DFE 3 118 (2003) Manual
DFE 3÷118
GB
USER’S MAINTENANCE GB
PIECES DE RECHANGE
AIR - COOLED
REFROIDISSEMENT A AIR
ISSUE • EDITION
2003
Dear Customer,
thank you for choosing our product. In order to get the best performance from this product, please read this
manual carefully. To avoid incorrect operation of the equipment and possible physical risk to the operator,
please read and strictly follow the instructions contained in this manual. Note, these instructions are in
addition to the safety rules that apply in the country where the dryer is installed.
Before packing for shipment each DF series refrigerated air dryer is subjected to a rigorous test to ensure
the absence of any manufacturing faults and to demonstrate that the device can perform all the functions
for which it has been designed.
Once the dryer has been properly installed according to the instructions in this manual, it will be ready for
use without any further adjustment.
The operation is fully automatic, and the maintenance is limited to few controls and some cleaning
operations, as detailed in the following chapters.
This manual must be maintained available in any moment for future references and it has to be
intended as inherent part of the relevant dryer.
Due to the continuous technical evolution, we reserve the right to introduce any necessary change without
giving previous notice.
Should you experience any trouble, or for further information, please do not hesitate to contact us.
IDENTIFICATION PLATE
The product identification plate,
on the back of the dryer, shows
all the primary data of the
machine.
Model Model
Upon installation, fill in the table
Serial No. Serial No.
copying the data shown on the
Nominal Flow Rate Nominal Flow Rate Nl/min
identification plate. This data
must always be provided to the Max Air Pressure Max Air Pressure barg
manufacturer or to the dealer Max Inlet Air Temp. Max Inlet Air Temp. °C
Manufactured Manufactured
WARRANTY CONDITIONS
For 12 months from the installation date, but no longer than 14 months from the delivery date, the warranty
covers faulty parts, which will be repaired or replaced free of charge, except the travel, hotel and restaurant
expenses of our technician.
The warranty doesn’t cover any responsibility for direct or indirect damages to persons, animals or
equipment caused by improper usage or maintenance, and it’s limited to manufacturing faults only.
The right to warranty repairs is subordinated to the strict compliance with the installation, use and
maintenance instructions contained in this manual.
The warranty will be immediately voided in case of even small changes or alterations to the dryer.
To initiate repairs during the warranty period, the data reported on the identification plate must be provided.
GB
1. SAFETY RULES
1.1 Definition of the safety symbols used
1.2 Warnings
1.3 Proper Use of the Dryer
2. INSTALLATION
2.1 Transport
2.2 Installation site
2.3 Installation layout
2.4 Correction factors
2.5 Connection to the Compressed Air System
2.6 Connection to the Mains
2.7 Condensate Drain
3. START UP
3.1 Preliminary Operations
3.2 First Start-Up
3.3 Operation and Switching-Off
4. TECHNICAL CHARACTERISTICS
4.1 Technical Features of the Dryers Series DFE 3÷23 (115/1/60)
4.2 Technical Features of the Dryers Series DFE 3÷23 (230/1/60)
4.3 Technical Features of the Dryers Series DFE 31÷52 (115/1/60)
4.4 Technical Features of the Dryers Series DFE 31÷75 (230/1/60)
4.5 Technical Features of the Dryers Series DFE 98-118 (230/1/60)
5. TECHNICAL DESCRIPTION
5.1 Control Panel
5.2 Operation
5.3 Flow Diagram DFE 3÷52
5.4 Flow Diagram DFE 31÷75
5.5 Flow Diagram DFE 98-118
5.6 Refrigerating Compressor
5.7 Condenser
5.8 Liquid receiver (DFE 98-118)
5.9 Dehydration Filter
5.10 Capillary tube
5.11 Liquid sight-glass (DFE 98-118)
5.12 Thermostatic valve (DFE 98-118)
5.13 Evaporator
5.14 Liquid separator
5.15 Hot Gas By-pass Solenoid Valve
5.16 Air-to-Air Exchanger
5.17 Condensate Separator
5.18 Refrigerant Pressure-Switch PB - PA - PV
5.19 DMC11 Air Dryer Controller
5.20 ADS93 Controller
5.21 Electrical Layout DFE 3÷23 (115/1/60)
5.22 Electrical Layout DFE 3÷23 (230/1/60)
5.23 Electrical Layout DFE 31÷52 (115/1/60)
5.24 Electrical Layout DFE 31÷75 (230/1/60)
5.25 Electrical Layout DFE 98-118
5.26 Electrical Layout DFE 98-118 - Connections
6. MAINTENANCE, TROUBLESHOOTING, SPARES AND DISMANTLING
6.1 Controls and Maintenance
6.2 Troubleshooting
6.3 Suggested Spare Parts
6.4 Dismantling of the Dryer
7. LIST OF ATTACHMENTS
7.1 Exploded View
GB
Before attempting any intervention on the dryer, read carefully the instructions reported in this use
and maintenance manual.
General warning sign. Risk of danger or possibility of damage to the machine. Read carefully the
text related to this sign.
Electrical hazard. The relevant text outlines conditions which could result fatal. The related
instructions must be strictly respected.
Danger hazard. Part or system under pressure.
Danger hazard. Component or system which during the operation can reach high temperature.
Danger hazard. It’s absolutely forbidden to breath the air treated with this apparatus.
Danger hazard: It’s absolutely forbidden to use water to extinguish fire on the dryer on in the
surrounding area.
Danger hazard. It’s absolutely forbidden to operate the machine when the panels are not in place.
ARIA
AIR
LUFT
AIR
Compressed air inlet connection point.
ARIA
AIR
LUFT
AIR
Compressed air outlet connection point.
Operations which can be worked out by the operator of the machine, if qualified 1.
NOTE : Text to be taken into account, but not involving safety precautions.
In designing this unit a lot of care has been devoted to the protection of the environment:
• CFC free refrigerants
• Foamed insulation parts produced without CFC
• Energy saving design
• Limited acoustic emission
• Dryer and relevant packaging composed of recyclable materials
Not to spoil our commitment, the user should follow the few ecological suggestions marked with
this sign.
1 Experienced and trained personnel acquainted with the relevant rules and laws, capable to perform the needed activities and to
identify and avoid possible dangerous situations while handling, installing, using and servicing the machine.
GB
1.2 WARNINGS
Compressed air is a highly hazardous energy source.
Never work on the dryer with parts under pressure.
Never point the compressed air or the condensate drain jet towards anybody.
The user is responsible for the installation of the dryer, which has to be executed on the basis of
the instructions given in the “Installation” chapter. Otherwise, the warranty will be voided and
dangerous situations for the personnel and/or damages to the machine could occur.
Only qualified personnel can use and service electrically powered devices. Before attempting any
maintenance action, the following conditions must be satisfied :
• Ensure that no part of the machine is under voltage and that it cannot be connected to the
mains.
• Ensure that no part of the dryer is under pressure and that it cannot be connected to the
compressed air system
These refrigeration air dryers contain R134,a type refrigerant fluid, not considered potential ozone
depleting. Maintenance on refrigeration systems must be carried out only by refrigeration
engineers according to local rules. R134,a may be dangerous for men only if it is present in bulk
concentrations. In case of leaks the room is to be aired before any intervention.
Any change to the machine or to the relevant operating parameters, if not previously verified and
authorized by the Manufacturer, in addition to create the possibility of dangerous conditions it will
void the warranty.
Don’t use water to extinguish fire on the dryer on in the surrounding area.
2.1 TRANSPORT
Once the integrity of the packaging is verified, place the unit near to the installation point and unpack the
contents.
• To move the packaged unit we suggest to use a suitable trolley or forklift. Transportation by hands is
discouraged.
• Keep the dryer always in vertical position. Turning it upside down some parts could be irreparably
damaged.
• Handle with care. Heavy blows could cause irreparable damage.
• Even when packaged, keep the machine protected from severity of the weather.
The packaging materials are recyclable. Each single material must be properly disposed in
a manner complying with the rules in force in the destination country.
GB
1,26
• Minimum ambient temperature +34 °F
(+1 °C). 0,51
-A-
OUT
7
3 4 8
1 Air compressor
IN
1 2 Aftercooler
5
3 Condensate separator
9
2 9
9
9
6
4 Pre-Filter
5 By-pass group
-B- 6 Dryer
OUT
7
7 Compressed air tank
3 4 8 8 Final filter
IN
1
9 Condensate drain
5
9
2 9 9
9
6
Type A installation is suggested when the compressor operates at reduced intermittence and the total
consumption equals the compressor flow rate.
Type B installation is suggested when the air consumption can consistently change with peak values highly
exceeding the flow rate of the compressors. The capacity of the tank must be sized in order to compensate
eventual instantaneous demanding conditions (peak air consumption).
GB
How to find the air flow capacity: How to select a suitable dryer for a given duty:
Air flow Nominal Factor Factor Factor Factor Minimum Design Factor Factor Factor Factor
capacity = duty X (F1) X (F2) X (F3) X (F4) Std. air = ÷ (F1) ÷ (F2) ÷ (F3) ÷ (F4)
flow rate air flow
Example: Example:
A DFE 31 has a nominal duty of 100 scfm (170 The procedure here is to list the operating
3
Nm /h). What is the maximum allowable flow conditions and then to locate the corresponding
through the dryer under the following operating numerical factors:
conditions: 3
− Design air flow = 118 scfm (200 Nm /h)
− Inlet air pressure = 115 psig (7.9 barg)
− Inlet air pressure = 115 psig (7.9 barg)
− Ambient temperature = 90 °F (32.2 °C)
− Ambient temperature = 90 °F (32.2 °C)
− Inlet air temperature = 100 °F (37.8 °C)
− Inlet air temperature = 100 °F (37.8 °C)
− Pressure DewPoint = 38 °F (3.3 °C)
− Pressure DewPoint = 38 °F (3.3 °C)
In order to select the correct dryer model the
Each item of data has a corresponding numerical required flow rate is to be divided by the correction
factor as follows: factors relating to above mentioned parameters:
= 112 scfm (190 Nm3/h) → This is the = 105 scfm (178 Nm3/h) → Therefore the
maximum flow rate that the dryer can accept model suitable for the conditions above is DFE 43
under these operating conditions. (137 scfm, 233 Nm3/h - nominal duty).
GB
In realizing the dryer, particular measures have been taken in order to limit the vibration which could occur
during the operation. Therefore we recommend to use of connecting pipes able to insulate the dryer from
possible vibrations originating from the line (flexible hoses, vibration damping fittings, etc.).
Before connecting the unit to the electric power, verify that the voltage and the frequency available on the
mains correspond to the data reported on the data plate of the dryer. In terms of voltage, a ±5% tolerance is
allowed.
Dryer supplied at 1/115/60 comes with a mains connecting cable already installed and ending with a North-
American standard plug 2 poles + ground.
Dryer supplied at 1/230/60 comes with a box for the connection to the mains.
The mains socket must be provided with a mains magneto-thermal differential breaker (I∆n=0.03A),
adjusted on the basis of the consumption of the dryer (see the nominal values on the data plate of the
dryer).
The cross section of the power supply cables must comply with the consumption of the dryer, while also
taking into account the ambient temperature, the conditions of the mains installation, the length of the
cables, and the requirements enforced by the local Power Provider.
It is mandatory to ensure the connection to the ground terminal.
Don’t use adapters on the mains socket. If necessary, have the pug replaced by qualified
personnel.
GB
The dryer comes already fitted with tubing in flexible plastics 6 mm (1/4" in) diameter and 1500 mm (59.1/16"
in) long for the connection to the collection plant (2 attacks for plastic flexible tube 6 mm, 1/4" in diameter on
dryers DFE 98-118).
The condensate drain operates through a solenoid valve protected with a mechanical strainer. In order to
avoid clogging of the solenoid valve, the condensate coming from the high efficiency separator is previously
filtered, than discharged. The solenoid valve coil is operated by an adjustable electronic timer or by dryer
controller (DMC11 - ADS93).
Connect and properly fasten the condensate drain to a collecting plant or container.
The drain cannot be connected to pressurized systems.
Don’t dispose the condensate to the environment.
The condensate collected in the dryer contains oil particles released in the air by the compressor.
Dispose the condensate in compliance with the local rules.
We suggest the installation of water-oil separator where to collect all the condensate coming from
compressors, dryers, tanks, filters, etc.
Before delivery, each dryer is submitted to accurate tests simulating real operating conditions.
Nevertheless, the unit could be damaged during transportation. We therefore suggest that you check the
integrity of the dryer upon arrival and to keep it under close watch during the first hours of operation.
The start-up must be performed by qualified personnel.
It’s mandatory that the engineer in charge will adopt safety operational conditions complying with
the local safety and accident prevention requirements.
The same engineer will be responsible for the proper and safe operation of the dryer.
Never operate the dryer if their panels are not in place.
Note : Note :
A DewPoint included in the green operating Taking into account the possible operating
area of the DMC11 is correct according to the conditions (flow-rate, temperature of the
possible working conditions (flow-rate, incoming air, ambient temperature, etc.) a
temperature of the incoming air, ambient temperature within 0 ºC and +8 ºC (+ 32 °F and
temperature, etc.). +46 °F) can be considered correct.
During the operation, the refrigerating compressor will run continuously. The dryer must remain on during
the full usage period of the compressed air, even if the air compressor works intermittently.
GB
210 mm
8.1/4 in
210 mm
8.1/4 in
6.5/16 in
160 mm
MODEL DFE 3 DFE 5 DFE 8 DFE 11 DFE 18 DFE 23
Air flow at nominal condition * [scfm] 12 17 27 35 56 75
[Nl/min] 340 480 765 990 1585 2125
[Nm³/h] 20 29 46 59 95 127
Pressure DewPoint at nominal condition * +38°F (+3°C) equal to 0.73 g/Nm³ of H2O
Ambient temperature nom. (max) [°F/°C] +100 (+113) / +38 (+45)
Min. ambient temperature [°F/°C] +34 / +1
Nom. (max) inlet air temperature [°F/°C] +100 (+113) / +38 (+45)
Nominal inlet air pressure [psig / barg] 100 / 7
Max. inlet air pressure [psig / barg] 218 / 15
Max. outlet air pressure drop - ∆p [psi / bar] 4.4 / 0.3
Inlet - outlet connections NPT-F 1/2” 3/4” 1”
Refrigerant type R 134.a (HFC) - CH 2 F-CF 3
Refrigerant quantity [oz] 8.7/8 7.7/8 12.3/8 9.3/4 13.1/4 15
[kg] 0.250 0.225 0.350 0.275 0.375 0.425
Cooling air flow [cfm / m³/h] 118 / 200 177 / 300
Electric Power Supply [V/Phase/Hz] 115/1/60
Nominal electric consumption [A / W] 2.2 / 190 2.7 / 220 3.9 / 310 3.8 / 350 4.5 / 400 6.1 / 540
Max. electric consumption [A / W] 2.5 / 210 3.2 / 250 4.8 / 350 4.5 / 400 5.3 / 450 7.4 / 620
Fan electric consumption [A / W] 0.30 / 27 0.54 / 40
Max. noise level at 40 in - 1 m [dbA] < 70
Weight [lb / kg] 68 / 31 71 / 32 79 / 36 82 / 37 84 / 38 88 / 40
* The nominal condition refers to an ambient temperature of +100 °F (+38 °C) with inlet air at 100 psig (7 barg) and
+100 °F (+38 °C).
GB
210 mm
8.1/4 in
mm
in
210 mm
2.9/16 3.3/8
8.1/4 in
85
65
MODEL DFE 3 DFE 5 DFE 8 DFE 11 DFE 18 DFE 23
Air flow at nominal condition * [scfm] 12 17 27 35 56 75
[Nl/min] 340 480 765 990 1585 2125
[Nm³/h] 20 29 46 59 95 127
Pressure DewPoint at nominal condition * +38°F (+3°C) equal to 0.73 g/Nm³ of H2O
Ambient temperature nom. (max) [°F/°C] +100 (+113) / +38 (+45)
Min. ambient temperature [°F/°C] +34 / +1
Nom. (max) inlet air temperature [°F/°C] +100 (+113) / +38 (+45)
Nominal inlet air pressure [psig / barg] 100 / 7
Max. inlet air pressure [psig / barg] 218 / 15
Max. outlet air pressure drop - ∆p [psi / bar] 4.4 / 0.3
Inlet - outlet connections NPT-F 1/2” 3/4” 1”
Refrigerant type R 134.a (HFC) - CH 2 F-CF 3
Refrigerant quantity [oz] 8.7/8 7.7/8 12.3/8 9.3/4 13.1/4 15
[kg] 0.250 0.225 0.350 0.275 0.375 0.425
Cooling air flow [cfm / m³/h] 118 / 200 177 / 300
Electric Power Supply [V/Phase/Hz] 230/1/60
Nominal electric consumption [A / W] 1.3 / 200 1.6 / 240 2.0 / 320 2.1 / 360 2.5 / 420 3.7 / 590
Max. electric consumption [A / W] 1.5 / 220 1.8 / 260 2.3 / 350 2.5 / 400 2.9 / 480 4.4 / 680
Fan electric consumption [A / W] 0.23 / 38 0.39 / 63
Max. noise level at 40 in - 1 m [dbA] < 70
Weight [lb / kg] 68 / 31 71 / 32 79 / 36 82 / 37 84 / 38 88 / 40
* The nominal condition refers to an ambient temperature of +100 °F (+38 °C) with inlet air at 100 psig (7 barg) and
+100 °F (+38 °C).
GB
320mm (245mm)
12.5/8in (9.5/8in)
( ) DFE 31
MODEL DFE 31 DFE 43 DFE 52
Air flow at nominal condition * [scfm] 100 137 168
[Nl/min] 2832 3879 4757
[Nm³/h] 170 233 285
Pressure DewPoint at nominal condition * +38°F (+3°C) equal to 0.73 g/Nm³ of H2O
Ambient temperature nom. (max) [°F/°C] +100 (+113) / +38 (+45)
Min. ambient temperature [°F/°C] +34 / +1
Nom. (max) inlet air temperature [°F/°C] +100 (+113) / +38 (+45)
Nominal inlet air pressure [psig / barg] 100 / 7
Max. inlet air pressure [psig / barg] 218 / 15
Max. outlet air pressure drop - ∆p [psi / bar] 4.4 / 0.3
Inlet - outlet connections NPT-F 1” 1.1/4” 1.1/2”
Refrigerant type R134.a (HFC) - CH2F-CF3
Refrigerant quantity [oz] 20.1/4 23 23.7/8
[kg] 0.575 0.650 0.675
Cooling air flow [cfm / m³/h] 235 / 400 265 / 450
Electric Power Supply [V/Phase/Hz] 115/1/60
Nominal electric consumption [A / W] 7.9 / 650 9.0 / 780 12.4 / 1000
Max. electric consumption [A / W] 9.8 / 780 11.3 / 960 15.6 / 1220
Fan electric consumption [A / W] 0.85 / 70 0.85 / 70 0.78 / 95
Max. noise level at 40 in - 1 m [dbA] < 70
Weight [lb / Kg] 126 / 57 170 / 77 203 / 92
* The nominal condition refers to an ambient temperature of +100 °F (+38 °C) with inlet air at 100 psig (7 barg) and
+100 °F (+38 °C).
GB
mm
in3.3/8
85
9.1/16 (5.1/2)
230 (140)
( ) DFE 31
MODEL DFE 31 DFE 43 DFE 52 DFE 61 DFE 75
Air flow at nominal condition * [scfm] 100 137 168 200 235
[Nl/min] 2832 3879 4757 5663 6654
[Nm³/h] 170 233 285 340 399
Pressure DewPoint at nominal condition * +38°F (+3°C) equal to 0.73 g/Nm³ of H2O
Ambient temperature nom. (max) [°F/°C] +100 (+113) / +38 (+45)
Min. ambient temperature [°F/°C] +34 / +1
Nom. (max) inlet air temperature [°F/°C] +100 (+113) / +38 (+45)
Nominal inlet air pressure [psig / barg] 100 / 7
Max. inlet air pressure [psig / barg] 218 / 15
Max. outlet air pressure drop - ∆p [psi / bar] 4.4 / 0.3
Inlet - outlet connections NPT-F 1” 1.1/4” 1.1/2” 2”
Refrigerant type R134.a (HFC) - CH2F-CF3
Refrigerant quantity [oz] 20.1/4 23 23.7/8 26.1/2 28.1/4
[kg] 0.575 0.650 0.675 0.750 0.800
Cooling air flow [cfm / m³/h] 235 / 400 265 / 450
Electric Power Supply [V/Phase/Hz] 230/1/60
Nominal electric consumption [A / W] 4.2 / 650 4.8 / 780 6.2 / 970 6.4 / 1200 6.6 / 1270
Max. electric consumption [A / W] 5.2 / 780 6.1 / 960 7.6 / 1170 8.5 / 1500 8.7 / 1580
Fan electric consumption [A / W] 0.43 / 70 0.35 / 87
Max. noise level at 40 in - 1 m [dbA] < 70
Weight [lb / Kg] 126 / 57 170 / 77 203 / 92 218 / 99 225 / 102
* The nominal condition refers to an ambient temperature of +100 °F (+38 °C) with inlet air at 100 psig (7 barg) and
+100 °F (+38 °C).
GB
4.1/2 in
115 mm
1 2 1 2
O ON
set
O ON
set
N set N set 4
3 K 3 K
O
N
K 3
K 3
5.2 OPERATION
The dryer described in this manual basically consists of two separated circuits: a compressed air circuit,
divided into two heat exchangers, and a refrigeration circuit.
The warm and humid entering air goes through an air-to-air exchanger before entering the evaporator (air-
to-refrigerant exchanger) where, due to the contact with the refrigeration circuit, it cools down to allow the
condensation of the humidity it contains.
The condensed humidity is than separated and expelled into the separator.
The cooled air goes through the air-to-air exchanger, where it partially warms up in cooling down the
entering warm air (pre-refrigeration).
The refrigeration circuit needed for these operations is basically composed of a refrigeration compressor, a
condenser and the evaporator, also called air-to-refrigerant exchanger.
GB
15
DMC
5
7 21 8
PV
10 1
16 2
6
M
14
4 3
13
11 12
15 DMC
8
18
ADS
5
7 17
PA
10
19
1
2
6
18 ADS M
14
4 3
20
13
11 12
18 ADS
11
10
12
1
8
PB PA
2
17 17 18
19 9
ADS M
16
ADS 18
20
6 5 4
3
15
13 14 ADS 18
13 14 15
5.7 CONDENSER
The condenser is the element in which the gas coming from the compressor is cooled down and condensed
becoming a liquid. Mechanically, it is formed by a copper tubing circuit (with the gas flowing inside)
immersed in an aluminum blades package. The cooling operation occurs via a high efficiency axial
ventilator which, in applying pressure on the air contained within the dryer, forces it into the blades package.
It’s mandatory that the temperature of the ambient air will not exceed the nominal values. It’s as well
important TO KEEP THE UNIT FREE FORM DUST AND OTHER IMPURITIES.
5.13 EVAPORATOR
Also called an air-to-refrigerant exchanger. The liquid formed in the condenser is evaporated in this part of
the circuit. In the evaporation phase the refrigerator tends to absorb the heat from the compressed air
present in the other side of the exchanger. The evaporator is immersed in the base of the dryer and
insulated with non-CFC expanded insulating foam. The part is entirely constructed in copper and the cooler
goes in the opposite direction to the air, thus contributing to limit pressure loss and to provide efficient
thermal exchange.
PA : This high-pressure switch, located on the pushing side on the compressor, is activated when the
pressure exceeds the pre-set value. It features a manual resetting button mounted on the controller
itself.
Calibrated pressure : R 134.a Stop 290 psig (20 barg) - Restart Manual
PV : Condenser unit fan control pressure safety switch (115/1/60 DFE 31÷52 only) placed at the outlet
side of condenser unit. It keeps the condensation temperature/pressure constant within preset
limits.
Calibrated pressure : R 134.a Stop 126 psig / 100°F - Restart 183 psig / 118°F
Stop 8.6 barg / 38°C - Restart 12.5 barg / 48°C
GB
The DMC11 device controls the whole operation of the dryer, and allows the calibration of the operating
parameters. The activation of the hot-gas solenoid valve is driven by means of a probe located at the end of
the evaporator, while a cyclic electronic timer drives the condensate drain solenoid valve at regular
intervals.
ON
The ADS93 device controls all the functions of the dryer, allowing also the calibration of all the parameters.
A probe located at the end of the evaporator pilots the activation of the hot gas by-pass solenoid valve. A
second probe, located at the end of the condenser, activate the relevant fan. Moreover, the ADS93
controller acts as a timer controlling the activation at regular intervals of the condensate drain solenoid
valve. During the final test, the following values are factory set:
• The hot gas by-pass solenoid valve is activated when a temperature below the SetPoint (+2ºC,
36°F) is detected, and it is deactivated at a temperature equal to the SetPoint + Differential
SetPoint (2 + 2 = +4ºC, 36 + 4 = +40°F). To modify the Set-Point (within the limits and set
while programming), hold down the key and change the value with the keys and .
• Fan of the condenser: It is active when the temperature exceeds + (25 + 5 = +30 ºC, 77 + 9 =
+86°F) and goes out when the temperature goes back to (+25 ºC, +77°F).
• Condensate drain solenoid valve: It remains on for a period equal to (3 seconds) with a 60 seconds
pause. To change the pause time between two successive drainage (within the limits and set
while programming) hold down the key and modify the value with the keys and .
SET-UP (PROGRAMMING)
At the start up, the dryer displays the current dew point temperature.
Pressing the key the condensation temperature will be visualized.
Holding down simultaneously the keys and for at leas 5 seconds the programming is initiated
and on the display will appear .
To select the desired parameter, press sequentially the key .
To change the value of the selected parameter, use the keys and .
All the parameters can be modified referring the following table.
Adjustment Pre-set
Display Description Equal to
Range value
Minimum limit of the Set-Point -9 ÷ 30 02 +2ºC(36°F)
Max. limit of the Set-Point ÷ 30 05 +5ºC (41°F)
Differential value of the Set-Point 1÷7 02 2ºC (4°F)
Minimum limit for the condensate drain pause 01 ÷ 99 06 60 sec
Max. limit for the condensate drain pause ÷ 99 18 180 sec
Duration of he condensate drainage 01 ÷ 99 30 3 sec
STOP temperature for the condenser fan 00 ÷ 99 25 +25ºC(77°F)
Differential value for he condenser fan 00 ÷ 15 05 5ºC (9°F)
Not in use -9 ÷ 09 - -
Nor in use -9 ÷ 09 - -
To exit the programming mode, press any time the key .
In case any entry is made within 10 seconds, the system exits automatically the programming mode.
GB
DMC11
Air Dryer Controller
POWER
PE
2 1 4 5 11 12
Vc
M M
PD
EVB EVD
PE
DMC11
Air Dryer Controller
POWER
2 1 4 5 11 12 Vc
M M
EVB EVD
PD
COMPRESSOR
FAN & CONTROLS CIRCUIT BREAKER
CIRCUIT BREAKER 10A
5A
Legend :
IG : Main switch VC : Condenser fan
K : Refrigerating compressor PD : DewPoint probe
KR : Compressor start-up relay EVB : Hot gas by-pass solenoid valve
KM : Compressor electric motor EVD : Condensate drain solenoid valve
KT : Compressor thermal protection
GB
DMC11
Air Dryer Controller
POWER
PE
Pv
2 1 4 5 11 12
Vc
M M
PD
EVB EVD
Y/G PE
15
6
6 15
ADS 93 Controller
POWER
Bn
Bn
8
CONNECTOR KR
PA
Bn
Bn
Bn
2 4
KM
Vc M
1
EVB EVD M
PD PF
KT
Bu
Bu
Bu
Bu
Bu
2
11
1
Legend :
IG : Main switch PA : Refrigerant pressure-switch (DFE 75)
VC : Condenser fan PV : Refrigerant pressure-switch (115/1/60 DFE 31÷52)
K : Refrigerating compressor PD : DewPoint probe
KR : Compressor start-up relay PF : Fan probe
KM : Compressor electric motor EVB : Hot gas by-pass solenoid valve
KT : Compressor thermal protection EVD : Condensate drain solenoid valve
GB
Y/G PE
3
R
15
6
PK
6 15
Bn
ADS 93 Controller
POWER P A
2 4
PROBE 1 PROBE 2 OUT 1 OUT 2 OUT 3
8 1 2 3 4 5 7 16 K
1
Bn
PB
9
8
7
4 2
KR
EV ES V 1
Bu
KM
M
Bn
Bn
Bn
Bn
Vc PK
Bu
Bu
Bu
Bu
Bu
K
S
EV ES V
4 4
FAN & CONTROLS COMPRESSOR
CIRCUIT BREAKER CIRCUIT BREAKER
5A 10A
3G14AWG
JOINT
BOX
SUPPLY
YG
PROBE PD
BN
BU
PROBE PF
ELECTRIC
OUT 1
OUT 2
OUT 3
YG
YG
BN
BU
PWR
8
SUPPLY
BOX
1 2 3 4 5 6 7 8 15 16
ES
ES
PK
PK
EV
EV
N
A
V
V
R
K
K
15
5
6
7
8
9
YG
YG
YG
YG
YG
YG
YG
BU
BN
BU
BN
BU
BN
BU
BN
BU
BN
PD
1
2
4
7
5
8
0 1
IG
12G14AWG
3G14AWG
3G14AWG
3G18AWG
3G18AWG
3G18AWG
PF
01
02
DETAIL :
FAN BOX CONNECTION
M 5A
EVD
YG
M M
1
4
3
9
8
EVB
YG
BU
BN
BK
K VC
N
L
YG
BN
BU
3G18AWG
Legend :
IG : Main switch PA : Refrigerant pressure switch (high-pressure)
VC : Condenser fan PB : Refrigerant pressure switch (low-pressure)
K : Refrigerating compressor PD : DewPoint probe
KR : Compressor start-up relay PF : Fan probe
KM : Compressor electric motor EVB : Hot gas by-pass solenoid valve
KT : Compressor thermal protection EVD : Condensate drain solenoid valve
GB
DAILY
• Verify that the DewPoint displayed on the controller is correct.
• Check the proper operation of the condensate drain systems.
• Verify the condenser for cleanliness.
EVERY 200 HOURS OR MONTHLY
• With an air jet (Max. 29 psig, 2 barg) blowing from inside towards outside clean the condenser;
repeat this operation blowing in the opposite way; be careful not to damage the aluminum blades
of the cooling package.
• Close the manual condensate drain valve, unscrew the mechanical strainer and clean it with
compressed air and a brush. Reinstall the strainer properly tight, and then open the manual valve.
• At the end, check the operation of the machine.
EVERY 1000 HOURS OR YEARLY
• Verify for tightness all the screws of the electric system and that all the “Faston” type
connections are in their proper position.
• Check the conditions of the condensate drain flexible hoses, and replace if necessary.
• At the end, check the operation of the machine.
6.2 TROUBLESHOOTING
The troubleshooting and the eventual checks have to be worked out by qualified personnel. Pay
particular attention in case of interventions on the refrigerating circuit. The refrigerating fluid, if
under pressure, while expanding could cause congelation burns and serious damage to the eyes,
should it get in contact with them.
The fan of the condenser Where installed - The “fan & control” circuit breaker(s) on the control panel
doesn’t work. was enabled - reset it pressing the button.
Verify the electric wiring.
PV pressure switch is faulty - contact a refrigeration engineer to replace it
(115/1/60 DFE 31÷52 only).Verify the electric wiring.
ADS93 - ADS93 doesn’t work - replace it.
If the fan still doesn’t work, replace it.
The dryer doesn’t drain Verify the electric wiring.
the condensate. The condensate drain strainer is clogged - remove and clean it.
The drain solenoid valve is jammed - remove and clean it.
The coil of the condensate drain solenoid valve burned out - replace it.
DMC11 - DMC11 doesn’t work - replace it.
ADS93 - ADS93 doesn’t work - replace it.
The DewPoint is too low - the condensate is frost - see specific point.
The dryer continuously The drain solenoid valve is jammed - remove and clean it.
drains condensate. Verify the electric wiring.
DMC11 - DMC11 doesn’t work - replace it.
ADS93 - ADS93 doesn’t work - replace it.
Water within the line. The dryer is off - switch it on.
Where installed - Untreated air flows through the by-pass unit - close the
by-pass.
The dryer doesn’t drain condensate - see specific point.
DewPoint too high - see specific section.
Where installed - The Check which of the following has caused the enabling of the controller :
high pressure controller 1. Room temperature is too high or there is poor ventilation; restore an
device PA was enabled. adequate ventilation.
2. The condenser is dirty - clean it.
3. The fan is not operating - see specific point.
4. There is a leak in the refrigerating fluid circuit - contact a refrigerating
systems engineer.
Restore the pressure controller by pressing the button on the controller itself
- verify the correct functioning of the dryer.
The PA pressure switch is faulty - contact a refrigeration engineer to replace it.
Where installed - The There is a leak in the refrigerating fluid circuit - contact a refrigerating
Low pressure controller systems engineer.
device PB was enabled. The pressure controller is automatically reset when the nominal conditions
are restored - check the correct functioning of the dryer.
DewPoint too high. The dryer is off - switch it on.
The refrigerating compressor doesn’t work - see specific point.
The fan of the condenser doesn’t work - see specific point.
The inlet air is too hot - restore the nominal conditions.
The inlet air flow rate is higher than the rate of the dryer - reduce the flow
rate - restore the normal conditions.
The ambient temperature is too high or the room aeration is insufficient -
provide proper ventilation.
The condenser is dirty - clean it.
The dryer doesn’t drain the condensate - see specific point.
DMC11 - LED of the DMC11 is always on - see specific point.
DMC11 - The set-point of the DMC11 is very high - see paragraph SET-UP
of the DMC11.
ADS93 - The green LED on the front of the ADS93 device is glowing
continuously - see specific point.
ADS93 - The ADS93 device is set at a dew point too high - see specific point.
There is a leak in the refrigerating fluid circuit - contact a refrigeration engineer.
GB
Excessive pressure drop The DewPoint is too low - the condensate is frost and blocks the air - see
within the dryer. the specific section.
Check for throttling the flexible connection hoses.
DewPoint too low. DMC11 - Verify the electric wiring of the DMC11.
ADS93 - Verify the electric wiring of the ADS93.
Verify the wiring of the hot gas by pass solenoid valve.
The coil of the hot gas by-pass solenoid valve burned out - replace it.
DMC11 - The probe of the DMC11 does not properly detect the temperature
of the evaporator - push the probe until it reaches the bottom of the
measurement well.
ADS93 - The probe of the ADS93 does not properly detect the temperature
of the evaporator - push the probe until it reaches the bottom of the
measurement well.
DMC11 - The set-point of the DMC11 is very low - see paragraph SET-UP
of the DMC11.
ADS93 - The set-point of the ADS93 is very low - see paragraph SET-UP of
the ADS93.
DMC11 - DMC11 Air Dryer Controller doesn’t work - replace it.
ADS93 - ADS93 Controller doesn’t work - replace it.
The hot gas solenoid valve is blocked - contact a refrigerating systems
engineer.
DMC11 - LED of the Verify the electric wiring of the probe of the DMC11.
DMC11 is always on. The first and the last led of the display of DMC11 blink simultaneously, the
probe doesn’t work - replace it.
DMC11 Air Dryer Controller doesn’t work - replace it.
ADS93 - The green LED Check the electric wiring of the probe (dew point) of the ADS93 device.
on the front of the The probe (dew point) of the electronic device ADS93 is faulty - replace it.
ADS93 device is The device ADS93 doesn’t work - replace it.
constantly on and on the
display appears the
message .
ADS93 - The green LED Check the electric wiring of the probe (fan) of the ADS93 device.
on the front of the The probe (fan) of the electronic device ADS93 is faulty - replace it.
ADS93 device is The device ADS93 doesn’t work - replace it.
constantly on and on the
display appears the
message .
GB
DFE Model
115/1/60 230/1/60
DESCRIPTION CODE 3 5 8 11 18 23 3 5 8 11 18 23
Condensate Y type drain filter 64355FF011 1 1 1 1 1 1 1 1 1 1 1 1
Fan motor 5210135005 1 1
Fan motor 5210135010 1 1 1 1
Fan motor 5210110005 1 1
Fan motor 5210110011 1 1 1 1
Fan of the fan motor 5215000010 1 1 1 1
Fan of the fan motor 5215000019 1 1 1 1 1 1 1 1
Fan grid 5225000010 1 1 1 1 1 1 1 1
DMC11 Air Dryer Controller 115V 5620130100 1 1 1 1 1 1
DMC11 Air Dryer Controller 230V 5620110100 1 1 1 1 1 1
DMC11 probe 5625NNN020 1 1 1 1 1 1 1 1 1 1 1 1
Condensate drain solenoid valve 64320FF005 1 1 1 1 1 1 1 1 1 1 1 1
Coil for solenoid valve 115V 64N22MM035 1 1 1 1 1 1
Coil for solenoid valve 230V 64N22MM005 1 1 1 1 1 1
By-pass solenoid valve 64120SS005 1 1 1 1 1 1
By-pass solenoid valve 64120SS010 1 1 1 1 1 1
Coil for by-pass solenoid valve 115V 64N22MM055 1 1 1 1 1 1
Coil for by-pass solenoid valve 230V 64N22MM060 1 1 1 1 1 1
Glowing switch 2P 0/1 5450SZN005 1 1 1 1 1 1 1 1 1 1 1 1
Panel circuit breaker 5A 54441K7005 2 2 2 2 2 2
Panel circuit breaker 10A 54441K7010 2 2 2 2 2 2
Refrigerating compressor 5015135001 1
Refrigerating compressor 5015135003 1
Refrigerating compressor 5015135005 1
Refrigerating compressor 5015135007 1
Refrigerating compressor 5015135009 1
Refrigerating compressor 5015135011 1
Refrigerating compressor 5015110001 1
Refrigerating compressor 5015110004 1
Refrigerating compressor 5015110007 1
Refrigerating compressor 5015110109 1
Refrigerating compressor 5015115010 1
Refrigerating compressor 5015115011 1
Suggested spare part.
NOTE : To order the suggested spare parts or any other part, it’s necessary to quote the data
reported on the identification plate.
GB
DFE Model
115/1/60 230/1/60
DESCRIPTION CODE 31 43 52 31 43 52 61 75 98 118
Condensate Y type drain filter 64355FF011 1 1 1 1 1 1 1 1 2 2
Fan motor 5210135015 1 1
Fan motor 5210135021 1
Fan motor 5210110017 1 1
Fan motor 5210110022 1 1 1
Fan of the fan motor 5215000025 1 1 1 1
Fan of the fan motor 5215000034 1 1 1 1
Fan grid 5225000027 1 1 1 1
Fan grid 5225000030 1 1 1 1
Fan 5250110071 1 1
DMC11 Air Dryer Controller 115V 5620130100 1 1 1
ADS93 Controller 230V 5620110001 1 1 1 1 1 1 1
DMC11 probe 5625NNN020 1 1 1
ADS93 probe 5625NNN021 1 1 1 1 1
ADS93 probe 5625NNN023 1 1 1 1 1 1 1
ADS93 probe (DewPoint) 5625NNN025 1 1
Condensate drain solenoid valve 64320FF011 1 1 1 1 1 1 1 1 2 2
Coil for sol. valve 64N22MM018 1 1 1
Coil for sol. valve 64N22MM021 1 1 1 1 1 2 2
By-pass solenoid valve 64120SS010 1 1
By-pass solenoid valve 64120SS015 1 1 1 1 1 1 1 1
Coil for by-pass solenoid valve 115V 64N22MM055 1 1 1
Coil for by-pass solenoid valve 230V 64N22MM060 1 1 1 1 1 1 1
Glowing switch 2P 0/1 5450SZN005 1 1 1 1 1 1 1 1
SEZ - Main Switch 5450SZN115 1 1
Panel circuit breaker 5A 54441K7005 2 2 2 2 2 2 2
Panel circuit breaker 10A 54441K7010 2 2 2 2 2 2 2
Refrigerating compressor 5015135020 1
Refrigerating compressor 5015135023 1
Refrigerating compressor 5015135026 1
Refrigerating compressor 5015115020 1
Refrigerating compressor 5015115023 1
Refrigerating compressor 5015115026 1
Refrigerating compressor 5015115029 1 1 1 1
Thermostatic valve 64130SS100 1 1
Refrigerant pressure switch PV 5655NNN150 1 1 1
Refrigerant pressure switch PA 5655NNN092 1
Refrigerant pressure switch PA-PB 5655NNN095 1 1
1 2 3
DFE 75 DFE 98-118 230/1/60
4
115/1/60 DFE 31÷52
F
Cher Client,
Nous vous remercions de la confiance que vous nous avez accordée et vous prions de lire attentivement le
présent manuel afin d’exploiter au maximum les caractéristiques de notre produit.
Afin de ne pas travailler dans de mauvaises conditions et d’éviter tout danger pour les opérateurs, nous
vous rappelons qu’il est indispensable d’observer scrupuleusement les directives figurant dans le présent
manuel ainsi que les normes de prévention des accidents en vigueur dans le pays où le matériel est utilisé.
Avant d’être emballé, chaque sécheur à cycle frigorifique de la série DF subit une série de tests sévères.
Cette phase sert à vérifier l’absence de vices de fabrication et que la machine remplit correctement les
fonctions pour lesquelles elle a été conçue. Après l’avoir correctement installé conformément aux
instructions données dans le présent manuel, le sécheur est prêt à l’emploi et n’a besoin d’aucun réglage.
Son fonctionnement est entièrement automatique; son entretien se limite à quelques contrôles et aux
opérations de nettoyage décrites en détail dans les chapitres suivants.
Le présent manuel doit être conservé afin de pouvoir le consulter à tout moment et fait partie
intégrante du sécheur que vous avez acheté.
En raison de l’évolution permanente de la technique, nous nous réservons le droit d’apporter toute
modification nécessaire sans préavis.
N’hésitez pas à nous contacter en cas de problème ou pour tout complément d’information.
PLAQUE D’IDENTIFICATION
Les caractéristiques principales
de la machine figurent sur la
plaque d’identification, qui se
trouve dans la partie postérieure
Modèle Model
du sécheur. Lors de
No. de série Serial No.
l’installation, remplir le tableau
Débit Nominale d’Air Nominal Flow Rate Nl/min
en reportant celles figurant sur
la plaque d’identification. Les Pression Maximum d’Air Max Air Pressure barg
CONDITION DE GARANTIE
La garantie couvre, pendant 12 mois à partir de la date de mise en service et une durée ne dépassant pas
14 mois à compter de la date d’expédition, les éventuelles pièces défectueuses à l’origine qui seront
réparées ou remplacées gratuitement. Sont exclus les frais de transport, de voyage, de logement et de
nourriture de nos techniciens.
La garantie exclut toute responsabilité pour des dommages directs ou indirects à des personnes, des
animaux et/des objets causés par un usage ou un entretien inadéquat et se limite seulement et uniquement
aux vices de fabrication.
Le droit à la réparation sous garantie est subordonné au respect des instructions d’installation, d’utilisation
et d’entretien figurant dans le présent manuel. La garantie devient immédiatement nulle en cas de
modification ou altération du sécheur, même si minime. Lors de la demande d’intervention sous garantie, il
est nécessaire de communiquer les données figurant sur la plaque d’identification du produit.
F
1. NORMES DE SECURITE
1.1 Définition des symboles utilisés
1.2 Avertissements
1.3 Utilisation correcte du sécheur
2. INSTALLATION
2.1 Transport
2.2 Lieu d’installation
2.3 Schéma d’installation
2.4 Facteurs de correction
2.5 Branchement à la prise d’air comprimé
2.6 Branchement à l’installation électrique
2.7 Évacuation de la condensation
3. MISE EN SERVICE
3.1 Préliminaires à la mise en service
3.2 Première mise en service
3.3 Marche et arrêt
4. CARACTERISTIQUES TECHNIQUES
4.1 Caractéristiques techniques sécheurs séries DFE 3÷23 (115/1/60)
4.2 Caractéristiques techniques sécheurs séries DFE 3÷23 (230/1/60)
4.3 Caractéristiques techniques sécheurs séries DFE 31÷52 (115/1/60)
4.4 Caractéristiques techniques sécheurs séries DFE 31÷75 (230/1/60)
4.5 Caractéristiques techniques sécheurs séries DFE 98-118 (230/1/60)
5. DESCRIPTION TECHNIQUE
5.1 Pupitre de commande
5.2 Description du fonctionnement
5.3 Schéma fonctionnel DFE 3÷52
5.4 Schéma fonctionnel DFE 31÷75
5.5 Schéma fonctionnel DFE 98-118
5.6 Compresseur frigorifique
5.7 Condenseur
5.8 Récepteur de liquide (DFE 98-118)
5.9 Filtre déshydrater
5.10 Tuyau capillaire
5.11 Témoin du liquide (DFE 98-118)
5.12 Vanne thermostatique (DFE 98-118)
5.13 Evaporateur
5.14 Séparateur de liquide
5.15 Electrovanne by-pass gaz chaud
5.16 Echangeur air-air
5.17 Séparateur de condensation
5.18 Pressostat gaz frigorigène PB - PA - PV
5.19 DMC11 Air Dryer Controller
5.20 ADS93 Controller
5.21 Schéma électrique DFE 3÷23 (115/1/60)
5.22 Schéma électrique DFE 3÷23 (230/1/60)
5.23 Schéma électrique DFE 31÷52 (115/1/60)
5.24 Schéma électrique DFE 31÷75 (230/1/60)
5.25 Schéma électrique DFE 98-118
5.26 Schéma électrique DFE 98-118 - Connexions
6. ENTRETIEN, RECHERCHE DES AVARIES, PIECES DE RECHANGE ET DEMOLITION
6.1 Contrôles et entretien
6.2 Recherche des avaries
6.3 Pièces détachées conseillées
6.4 Démolition du sécheur
7. LISTE DES ANNEXES
7.1 Vue éclatée
F
Risque de danger; élément ou installation pouvant atteindre des températures élevées pendant le
fonctionnement.
Risque de danger; interdiction absolue de respirer l’air traité avec cet appareil.
Risque de danger; interdiction absolue d’utiliser de l’eau pour éteindre des incendies à proximité
ou sur le sécheur.
Risque de danger; interdiction absolue de faire marcher la machine avec les panneaux ouverts.
Opérations d’entretien et/ou contrôle pour lesquels il est nécessaire de prendre des précautions
particulières et devant être effectuées par du personnel qualifié 1.
ARIA
AIR
LUFT
AIR
Point de branchement pour l’entrée de l’air comprimé.
ARIA
AIR
LUFT
AIR
Point de branchement pour la sortie de l’air comprimé.
Opérations pouvant être effectuées par le personnel chargé de faire fonctionner la machine, à
condition qu’il soit qualifié 1.
REMARQUE : Phrase devant attirer l’attention mais qui donne pas d’instructions pour la sécurité.
Nous sommes efforcés de concevoir et de fabriquer le sécheur en respectant l’environnement :
• Réfrigérants sans CFC
• Mousses isolantes expansées sans l’aide de CFC
• Précautions visant à réduire la consommation d’énergie
• Niveau de pollution sonore limité
• Sécheur et emballage réalisés à partir de matériaux recyclables
Pour ne pas annihiler nos efforts, l’utilisateur est invité à suivre les simples avertissements de
nature écologique portant ce symbole.
1 Il s’agit de personnes jouissant d’une certaine expérience, possédant une formation technique et au courant des normes et des
réglementations, en mesure d’effectuer les interventions nécessaires et de reconnaître et éviter tout éventuel danger lors de la
manutention, de l’installation, de l’utilisation et de l’entretien de la machine.
F
1.2 AVERTISSEMENTS
L’air comprimé est une source d’énergie très dangereuse.
Ne jamais travailler sur le sécheur s’il a des pièces sous pression.
Ne pas diriger le jet d’air comprimé ou d’évacuation de la condensation vers des personnes.
L’utilisateur doit veiller à faire installer le sécheur conformément aux instructions données dans le
chapitre “Installation”.
Dans le cas contraire, la garantie devient nulle, certaines situations à risque peuvent se créer pour
les opérateurs et/ou entraîner une détérioration de la machine.
Seul un personnel qualifié est habilité à utiliser et à effectuer les opérations d’entretien d’appareils
à alimentation électrique. Avant de commencer à effectuer toute opération d’entretien, il est
nécessaire d’observer les instructions suivantes :
• S’assurer que la machine n’ait pas de pièces sous pression et qu’elle ne puisse pas être
rebranchée au réseau d’alimentation électrique.
• S’assurer que le sécheur n’ait pas de pièces sous pression et qu’il ne puisse pas être rebranché
à l’installation de l’air comprimé.
Ces sécheurs à circuit frigorifique contiennent fluide réfrigérant type R134,a, n’est pas considéré
potentiellement nuisible pour l’ozone. La maintenance du circuit frigorifique doit être effectuée
exclusivement par du personnel qualifié, en accord avec les normes du pays en vigueur. Le
réfrigérant R134.a peut être dangereux pour l’homme seulement si présent en concentrations
élevées. En cas de pertes, le local doit être aéré avant chaque intervention.
Toute modification de la machine ou de ses paramètres de fonctionnement annulera la garantie si
elle n’est pas vérifiée et autorisée au préalable par le Constructeur et peut devenir une source de
danger.
Ne pas utiliser d’eau pour éteindre les incendies à proximité ou sur le sécheur.
2.1 TRANSPORT
S’assurer que l’emballage est parfaitement intègre, placer l’unité près du lieu d’installation choisi et
procéder à l’ouverture de l’emballage.
• Pour déplacer l’unité dans son emballage, on conseille d’utiliser un chariot adapté ou un élévateur. Le
transport à main est déconseillé.
• Maintenir toujours le sécheur en position verticale. D’éventuels renversements peuvent abîmer des
éléments de l’unité.
• Déplacer le sécheur avec soin. Des chocs violents peuvent causer des dommages irréparables.
• Tenir la machine, même emballée, à l’abri des intempéries.
L’emballage est réalisé dans une matière recyclable. Éliminer l’emballage de façon adéquate
et conformément aux prescriptions en vigueur dans le pays d’utilisation.
F
1,26
supporter le poids du sécheur.
• Température ambiante minimum de +34 °F
0,51
(+1 °C).
• Température ambiante maximum de +113 °F DFE 3÷23
(+45°C).
• Faire en sorte de laisser 40 in (1 mètre)
minimum de chaque côté du sécheur afin de
faciliter la ventilation et toute éventuelle
opération d’entretien.
Le sécheur n’a pas besoin de fixation au plan
d’appui.
Seulement des installations particulières
requièrent des ancrages (sécheur sur brides,
suspendus, etc.).
-A-
OUT
7
3 4 8
1 Compresseur d’air
IN
1 2 Réfrigérant final
5
3 Séparateur de condensation
9
2 9
9
9
6
4 Pre - Filtre
5 Groupe by-pass
-B- 6 Sécheur
OUT
7
7 Bac air comprimé
3 4 8 8 Filtre final
IN
1
9 Purgeur de condensation
5
9
2 9 9
9
6
Il est conseillé d’utiliser l’installation du type A lorsque les compresseurs marchent par intermittence réduite
tandis que la somme des consommations équivaut au débit du compresseur.
Il est conseillé d’utiliser l’installation du type B lorsque les consommations d’air sont très variables et les
valeurs instantanées sont supérieures au débit des compresseurs. Le bac doit avoir une capacité
suffisante à satisfaire avec l’air emmagasiné les demandes de courte durée et valeur élevée (impulsives).
F
Comment déterminer le débit d'air réel : Comment déterminer le bon modèle de sécheur
une fois les conditions de service connues :
Débit Débit Facteur Facteur Facteur Facteur Débit Débit Facteur Facteur Facteur Facteur
d'air
réel
= nominal X
(F1) X (F2) X (F3) X (F4) de principe
= d'air
demandé
÷ (F1) ÷ (F2) ÷ (F3) ÷ (F4)
Exemple : Exemple :
Un sécheur DFE 31 a un débit nominal de Sachant que les paramètres de fonctionnement
3
principe de 100 scfm (170 Nm /h). Quel est le sont les suivants :
débit maximum pouvant être obtenu dans les 3
− Débit d'air demandé = 118 scfm (200 Nm /h)
conditions de fonctionnement suivantes :
− Pression air en entrée = 115 psig (7.9 barg)
− Pression air en entrée = 115 psig (7.9 barg)
− Température ambiante = 90 °F (32.2 °C)
− Température ambiante = 90 °F (32.2 °C)
− Température air en entrée = 100 °F (37.8 °C)
− Température air en entrée = 100 °F (37.8 °C)
− DewPoint sous pression = 38 °F (3.3 °C)
− DewPoint sous pression = 38 °F (3.3 °C)
= 112 scfm (190 Nm3/h) → C'est le débit = 105 scfm (178 Nm3/h) → Pour
d'air maximum que le sécheur est en mesure de satisfaire ces critères, sélectionner le modèle DFE
supporter aux conditions de travail ci-dessus. 43 (dont le débit nominal de principe est de 137
3
scfm, 233 Nm /h).
F
Le sécheur a été conçu en prenant certaines précautions de façon à réduire les vibrations susceptibles de
se produire pendant son fonctionnement. Par conséquent, il est conseillé d’utiliser des tuyaux de
raccordement protégeant le sécheur contre d’éventuelles vibrations provenant de la ligne (tuyaux flexibles,
joints anti-vibrations, etc.).
Avant d’effectuer le branchement, s’assurer que la tension et la fréquence disponibles dans l’installation
d’alimentation électrique correspondent aux paramètres figurant sur la plaque du sécheur. Une tolérance de
±5% par rapport à la tension indiquée sur la plaque est admise.
A sa livraison, les sécheurs est prêt à être branché à l’installation électrique à l’aide d’un câble se terminant
par une fiche avec le standard Nord-Américain (prise de courant avec 2 pôles + terre) sur sécheur modèle
115/1/60. Lors de la livraison le sécheur est prêt pour être raccordé au secteur par l’intermédiaire d’un
boîtier électrique sur sécheur modèle 230/1/60.
Installer une prise d’alimentation dotée d’un interrupteur de secteur différentiel (I∆n=0.03A) et
magnétothermique taré de façon adéquate par rapport à l’absorption du sécheur (se reporter aux
paramètres figurant sur le sécheur).
Les câbles d’alimentation doivent avoir une section adéquate par rapport à l’absorption du sécheur, tenant
compte de la température ambiante, des conditions de pose, de leur longueur et conformément aux normes
de référence de l’Organisme Energétique Nationale.
Il est indispensable de garantir le branchement à l’installation de dispersion à terre.
Ne pas utiliser d’adaptateurs pour la fiche d’alimentation. Faire éventuellement remplacer la prise
par du personnel qualifié.
F
Le sécheur est livré prêt à être raccordé à l’installation de collecte du condensat à l’aide de deux dispositifs
de fixation pour tuyau en plastique flexible de 6 mm (1/4" in) de diamètre et de 1500 mm (59.1/16" in) de
longueur (2 raccords pour tuyau en plastique de 6 mm, 1/4" in de diamètre sur DF*98-118).
L’évacuation du condensat est assurée par une électrovanne protégée par un filtre mécanique; le
condensat prélevé par le séparateur à haute efficacité est tout d’abord filtré pour éviter que l’électrovanne
ne se bloque pour être ensuite expulsé. La bobine d'électrovanne est commandée par l’instrument
électronique DMC11 ou ADS93. Raccorder le dispositif d’évacuation du condensat à une installation ou un
récipient de collecte et le fixer correctement.
Le dispositif d’évacuation ne peut pas être introduit dans de circuit sous pression.
Ne pas laisser la condensation s’évacuer dans l’atmosphère.
La condensation séparée du sécheur contient des particules d’huile laissées par le compresseur
dans l’air. Éliminer la condensation conformément aux normes en vigueur dans le pays
d’installation. Il est conseillé d’installer un séparateur eau-huile permettant d’acheminer toute la
condensation à évacuer : compresseurs, sécheurs, réservoirs, filtres, etc.
Arrêt : Arrêt :
Remarque : Remarque :
210 mm
8.1/4 in
210 mm
8.1/4 in
6.5/16 in
160 mm
MODELE DFE 3 DFE 5 DFE 8 DFE 11 DFE 18 DFE 23
Débit d’air * [scfm] 12 17 27 35 56 75
[Nl/min] 340 480 765 990 1585 2125
[Nm³/h] 20 29 46 59 95 127
Point de rosée * +38°F (+3°C) égale à 0.73 g/Nm³ de H2O
Température ambiante nom. (max) [°F/°C] +100 (+113) / +38 (+45)
Température ambiante minimum [°F/°C] +34 / +1
Température air entrée nom. (max) [°F/°C] +100 (+113) / +38 (+45)
Pression nominale air entrée [psig / barg] 100 / 7
Pression maximum air entrée [psig / barg] 218 / 15
Chute de pression en sortie - ∆p [psi / bar] 4.4 / 0.3
Branchements entrée - sortie NPT-F 1/2” 3/4” 1”
Type de réfrigérant R 134.a (HFC) - CH 2 F-CF 3
Charge réfrigérant [oz] 8.7/8 7.7/8 12.3/8 9.3/4 13.1/4 15
[kg] 0.250 0.225 0.350 0.275 0.375 0.425
Débit de l’air de refroidissement [cfm / m³/h] 118 / 200 177 / 300
Alimentation électrique standard [V/Phase/Hz] 115/1/60
Puissance électrique nominale [A / W] 2.2 / 190 2.7 / 220 3.9 / 310 3.8 / 350 4.5 / 400 6.1 / 540
Puissance électrique maximum [A / W] 2.5 / 210 3.2 / 250 4.8 / 350 4.5 / 400 5.3 / 450 7.4 / 620
Puissance électrique ventilateur [A / W] 0.30 / 27 0.54 / 40
Niveau de pression sonore à 40 in - 1 m [dbA] < 70
Poids [lbs / kg] 68 / 31 71 / 32 79 / 36 82 / 37 84 / 38 88 / 40
* Le condition nominal se réfère à une température ambiante de +100 °F (+38 °C) et de l’air en entrée à 100 psig
(7 barg) et +100 °F (+38 °C).
F
210 mm
8.1/4 in
mm
in
210 mm
2.9/16 3.3/8
8.1/4 in
85
65
MODELE DFE 3 DFE 5 DFE 8 DFE 11 DFE 18 DFE 23
Débit d’air * [scfm] 12 17 27 35 56 75
[Nl/min] 340 480 765 990 1585 2125
[Nm³/h] 20 29 46 59 95 127
Point de rosée * +38°F (+3°C) égale à 0.73 g/Nm³ de H2O
Température ambiante nom. (max) [°F/°C] +100 (+113) / +38 (+45)
Température ambiante minimum [°F/°C] +34 / +1
Température air entrée nom. (max) [°F/°C] +100 (+113) / +38 (+45)
Pression nominale air entrée [psig / barg] 100 / 7
Pression maximum air entrée [psig / barg] 218 / 15
Chute de pression en sortie - ∆p [psi / bar] 4.4 / 0.3
Branchements entrée - sortie NPT-F 1/2” 3/4” 1”
Type de réfrigérant R 134.a (HFC) - CH 2 F-CF 3
Charge réfrigérant [oz] 8.7/8 7.7/8 12.3/8 9.3/4 13.1/4 15
[kg] 0.250 0.225 0.350 0.275 0.375 0.425
Débit de l’air de refroidissement [cfm / m³/h] 118 / 200 177 / 300
Alimentation électrique standard [V/Phase/Hz] 230/1/60
Puissance électrique nominale [A / W] 1.3 / 200 1.6 / 240 2.0 / 320 2.1 / 360 2.5 / 420 3.7 / 590
Puissance électrique maximum [A / W] 1.5 / 220 1.8 / 260 2.3 / 350 2.5 / 400 2.9 / 480 4.4 / 680
Puissance électrique ventilateur [A / W] 0.23 / 38 0.39 / 63
Niveau de pression sonore à 40 in - 1 m [dbA] < 70
Poids [lbs / kg] 68 / 31 71 / 32 79 / 36 82 / 37 84 / 38 88 / 40
* Le condition nominal se réfère à une température ambiante de +100 °F (+38 °C) et de l’air en entrée à 100 psig
(7 barg) et +100 °F (+38 °C).
F
320mm (245mm)
12.5/8in (9.5/8in)
( ) DFE 31
MODELE DFE 31 DFE 43 DFE 52
Débit d’air * [scfm] 100 137 168
[Nl/min] 2832 3879 4757
[Nm³/h] 170 233 285
Point de rosée * +38°F (+3°C) égale à 0.73 g/Nm³ de H2O
Température ambiante nom. (max) [°F/°C] +100 (+113) / +38 (+45)
Température ambiante minimum [°F/°C] +34 / +1
Température air entrée nom. (max) [°F/°C] +100 (+113) / +38 (+45)
Pression nominale air entrée [psig / barg] 100 / 7
Pression maximum air entrée [psig / barg] 218 / 15
Chute de pression en sortie - ∆p [psi / bar] 4.4 / 0.3
Branchements entrée - sortie NPT-F 1” 1.1/4” 1.1/2”
Type de réfrigérant R134.a (HFC) - CH2F-CF3
Charge réfrigérant [oz] 20.1/4 23 23.7/8
[kg] 0.575 0.650 0.675
Débit de l’air de refroidissement [cfm / m³/h] 235 / 400 265 / 450
Alimentation électrique standard [V/Phase/Hz] 115/1/60
Puissance électrique nominale [A / W] 7.9 / 650 9.0 / 780 12.4 / 1000
Puissance électrique maximum [A / W] 9.8 / 780 11.3 / 960 15.6 / 1220
Puissance électrique ventilateur [A / W] 0.85 / 70 0.85 / 70 0.78 / 95
Niveau de pression sonore à 40 in - 1 m [dbA] < 70
Poids [lbs / kg] 126 / 57 170 / 77 203 / 92
* Le condition nominal se réfère à une température ambiante de +100 °F (+38 °C) et de l’air en entrée à 100 psig
(7 barg) et +100 °F (+38 °C).
F
mm
in3.3/8
85
9.1/16 (5.1/2)
230 (140)
( ) DFE 31
MODELE DFE 31 DFE 43 DFE 52 DFE 61 DFE 75
Débit d’air * [scfm] 100 137 168 200 235
[Nl/min] 2832 3879 4757 5663 6654
[Nm³/h] 170 233 285 340 399
Point de rosée * +38°F (+3°C) égale à 0.73 g/Nm³ de H2O
Température ambiante nom. (max) [°F/°C] +100 (+113) / +38 (+45)
Température ambiante minimum [°F/°C] +34 / +1
Température air entrée nom. (max) [°F/°C] +100 (+113) / +38 (+45)
Pression nominale air entrée [psig / barg] 100 / 7
Pression maximum air entrée [psig / barg] 218 / 15
Chute de pression en sortie - ∆p [psi / bar] 4.4 / 0.3
Branchements entrée - sortie NPT-F 1” 1.1/4” 1.1/2” 2”
Type de réfrigérant R134.a (HFC) - CH2F-CF3
Charge réfrigérant [oz] 20.1/4 23 23.7/8 26.1/2 28.1/4
[kg] 0.575 0.650 0.675 0.750 0.800
Débit de l’air de refroidissement [cfm / m³/h] 235 / 400 265 / 450
Alimentation électrique standard [V/Phase/Hz] 230/1/60
Puissance électrique nominale [A / W] 4.2 / 650 4.8 / 780 6.2 / 970 6.4 / 1200 6.6 / 1270
Puissance électrique maximum [A / W] 5.2 / 780 6.1 / 960 7.6 / 1170 8.5 / 1500 8.7 / 1580
Puissance électrique ventilateur [A / W] 0.43 / 70 0.35 / 87
Niveau de pression sonore à 40 in - 1 m [dbA] < 70
Poids [lbs / kg] 126 / 57 170 / 77 203 / 92 218 / 99 225 / 102
* Le condition nominal se réfère à une température ambiante de +100 °F (+38 °C) et de l’air en entrée à 100 psig
(7 barg) et +100 °F (+38 °C).
F
4.1/2 in
115 mm
1 2 1 2
O ON
set
O ON
set
N set N set 4
3 K 3 K
O
N
K 3
K 3
15
DMC
5
7 21 8
PV
10 1
16 2
6
M
14
4 3
13
11 12
15 DMC
8
18
ADS
5
7 17
PA
10
19
1
2
6
18 ADS M
14
4 3
20
13
11 12
18 ADS
11
10
12
1
8
PB PA
2
17 17 18
19 9
ADS M
16
ADS 18
20
6 5 4
3
15
13 14 ADS 18
13 14 15
5.7 CONDENSEUR
Le condenseur est l’élément du circuit où le gaz provenant du compresseur est refroidi et condensé en
passant à l’état liquide. Il se présente sous forme de circuit de tuyaux en cuivre (à l’intérieur duquel circule
le gaz) intégrés dans des ailettes de refroidissement en aluminium. Le refroidissement se produit grâce à
un ventilateur axial très efficace. Il est indispensable que la température de l’air ambiant ne dépasse pas les
valeurs figurant sur la plaque. Il est également extrêmement important que LA BATTERIE SOIT
TOUJOURS EXEMPTE DE DEPOTS DE POUSSIERE ET DE TOUTES AUTRE IMPURETE.
5.13 EVAPORATEUR
Egalement appelé échangeur de chaleur air- réf rigérant. Dans cette partie se produit l’évaporation du
liquide qui s’est formé dans le condensateur. Pendant la phase d’évaporation, le cryogène tend à absorber
la chaleur de l’air comprimé présent dans l’autre côté de l’échangeur. L’évaporateur, enroulé en spirale, est
immergé dans la base du sécheur et calorifugé avec de la mousse isolante expansée sans CFC. La
construction entièrement en cuivre et le flux du réfrigérant opposé à celui de l’air contribuent à limiter la
chute de pression et à obtenir une efficacité élevée dans l’échange thermique.
PA : Pressostat haut pression : placé sur le côté refoulant du compresseur; il intervient si la pression
augmente au-delà de celle réglée. Le réarmement est manuel et s’effectue à l’aide d’une touche
située sur le pressostat.
Pressions de réglage : R 134.a Arrêt 290 psig (20 barg) - Départ manuel
PV : Le pressostat de ventilateur est positionné sur la ligne haute pression du compresseur. Il permet de
maintenir la température/pression de condensation constante à l'intérieur des valeurs prévues
(115/1/60 PDE 30÷50 -S).
Pressions de réglage : R 134.a Arrêt 126 psig / 100°F - Départ 183 psig / 118°F
Arrêt 8.6 barg / 38°C - Départ 12.5 barg / 48°C
F
L’instrument DMC11 contrôle toutes les opérations du sécheur permettant le calibrage des paramètres de
fonctionnement. L’intervention de l’électrovanne du by-pass gaz chaud est commandée par une sonde
positionnée à la fin de l’évaporateur; un timer électronique cyclique commande, à intervalles réguliers,
l’électrovanne de l’évacuation condensat.
ON
L’indication de “hors échelle” est représentée par l’intermittence du premier et du dernier LED du display,
respectivement pour le dépassement de la limite inférieure ou supérieure du champ de mesure.
En appuyant sur la touche il est possible de sortir de la programmation n’importe quand ; si l’on n’effectue
aucune opération pendant 2 minutes, l’instrument sort automatiquement de la programmation.
F
L’instrument ADS93 contrôle toutes les fonctions du sécheur en permettant le réglage de tous les paramètres.
A l’aide d’une sonde placée à la fin de l’évaporateur, l’intervention de l’électrovanne de by-pass gaz chaud est
commandée tandis qu’une deuxième sonde placée à la fin du condensateur active son ventilateur. L’ADS93
Controller fait en outre office de temporisateur en commandant à intervalles réguliers l’électrovanne
d’évacuation de la condensation. Lors des essais, les valeurs d’intervention standard suivantes sont définies :
• Electrovanne by-pass gaz chaud : s’active lorsqu’une température inférieure au Set Point (+2ºC, 36°F) est
relevée et se désactive à une température égale au Set-Point + Différentiel Set-Point (2 + 2 = +4ºC, 36 + 4 =
+40°F). Pour modifier le Set-Point (dans les limites et définies lors de la programmation), appuyer de
façon continue sur la touche et modifier la valeur à l’aide des touches et .
• Ventilateur du condensateur : est actif si la température dépasse + (25 + 5 = +30 ºC, 77 + 9 =
+86°F) et s’éteint lorsqu’elle retourne à (+25 ºC, +77°F).
• Electrovanne d’évacuation de la condensation : s’active pendant une durée de (3 secondes) avec
une pause de 60 secondes. Pour modifier la pause entre deux cycles d’évacuation (dans les limites
et définies lors de la programmation), appuyer de façon continue sur la touche et modifier la
valeur à l’aide des touches et .
SET-UP (PROGRAMMATION)
Lors de la mise sous tension du sécheur, l’écran affiche la température du point de rosée actuel.
En appuyant sur la touche il est possible d’afficher la température de condensation.
En appuyant de façon continue et simultanée sur les touches et pendant au moins 5 secondes, on
active la programmation et s’affiche à l’écran.
Pour sélectionner le paramètre voulu, appuyer séquentiellement sur la touche .
Pour modifier la valeur du paramètre sélectionné, appuyer sur les touches et .
Tous les paramètres peuvent être modifiés suivant le diagramme figurant ci-dessous.
Plage de Valeur
Affichage Description Soit
réglage définie
Limite minimum du Set-Point -9 ÷ 30 02 +2ºC (36°F)
Limite maximum du Set-Point ÷ 30 05 +5ºC(41°F)
Valeur différentielle du Set-Point 1÷7 02 2ºC (4°F)
Limite minimum de la pause évacuation condensation 01 ÷ 99 06 60 sec
Limite maximum de la pause évacuation condensation ÷ 99 18 180 sec
Temps d’évacuation de la condensation 01 ÷ 99 30 3 sec
Température de STOP du ventilateur du condensateur 00 ÷ 99 25 +25ºC(77°F)
Valeur différentielle du ventilateur du condensateur 00 ÷ 15 05 5ºC (9°F)
Pas utilisé -9 ÷ 09 - -
Pas utilisé -9 ÷ 09 - -
Il est possible de sortir de la programmation à tout moment en appuyant sur la touche .
Si aucune opération n’est effectuée dans les 10 secondes, l’instrument sort automatiquement de la programmation.
F
DMC11
Air Dryer Controller
POWER
PE
2 1 4 5 11 12
Vc
M M
PD
EVB EVD
PE
DMC11
Air Dryer Controller
POWER
2 1 4 5 11 12 Vc
M M
EVB EVD
PD
COMPRESSOR
FAN & CONTROLS CIRCUIT BREAKER
CIRCUIT BREAKER 10A
5A
Légende :
IG : Interrupteur général VC : Ventilateur condensateur
K : Compresseur frigorifique PD : Sonde DewPoint
KR : Relais démarrage compresseur EVB : Electrovanne by-pass gaz chaud
KM : Moteur électrique compresseur EVD : Electrovanne évac. condensat
KT : Protection thermique compresseur
F
DMC11
Air Dryer Controller
POWER
PE
Pv
2 1 4 5 11 12
Vc
M M
PD
EVB EVD
Y/G PE
15
6
6 15
ADS 93 Controller
POWER
Bn
Bn
8
CONNECTOR KR
PA
Bn
Bn
Bn
2 4
KM
Vc M
1
EVB EVD M
PD PF
KT
Bu
Bu
Bu
Bu
Bu
2
11
1
Légende :
IG : Interrupteur général PA : Pressostat gaz frigorigène (DFE 75)
VC : Ventilateur condensateur PV : Pressostat gaz frigorigène (115/1/60 DFE 31÷52)
K : Compresseur frigorifique PD : Sonde DewPoint
KR : Relais démarrage compresseur PF : Sonde Ventilateur
KM : Moteur électrique compresseur EVB : Electrovanne by-pass gaz chaud
KT : Protection thermique compresseur EVD : Electrovanne évac. condensat
F
Y/G PE
3
R
15
6
PK
6 15
Bn
ADS 93 Controller
POWER P A
2 4
PROBE 1 PROBE 2 OUT 1 OUT 2 OUT 3
8 1 2 3 4 5 7 16 K
1
Bn
PB
9
8
7
4 2
KR
EV ES V 1
Bu
KM
M
Bn
Bn
Bn
Bn
Vc PK
Bu
Bu
Bu
Bu
Bu
K
S
EV ES V
4 4
FAN & CONTROLS COMPRESSOR
CIRCUIT BREAKER CIRCUIT BREAKER
5A 10A
3G14AWG
JOINT
BOX
SUPPLY
YG
PROBE PD
BN
BU
PROBE PF
ELECTRIC
OUT 1
OUT 2
OUT 3
YG
YG
BN
BU
PWR
8
SUPPLY
BOX
1 2 3 4 5 6 7 8 15 16
ES
ES
PK
PK
EV
EV
N
A
V
V
R
K
K
15
5
6
7
8
9
YG
YG
YG
YG
YG
YG
YG
BU
BN
BU
BN
BU
BN
BU
BN
BU
BN
PD
1
2
4
7
5
8
0 1
IG
12G14AWG
3G14AWG
3G14AWG
3G18AWG
3G18AWG
3G18AWG
PF
01
02
DETAIL :
FAN BOX CONNECTION
M 5A
EVD
YG
M M
1
4
3
9
8
EVB
YG
BU
BN
BK
K VC
N
L
YG
BN
BU
3G18AWG
Légende :
IG : Interrupteur général PA : Pressostat gaz frigorigène (haut pression)
VC : Ventilateur condensateur PB : Pressostat gaz frigorigène (basse pression)
K : Compresseur frigorifique PD : Sonde DewPoint
KR : Relais démarrage compresseur PF : Sonde Ventilateur
KM : Moteur électrique compresseur EVB : Electrovanne by-pass gaz chaud
KT : Protection thermique compresseur EVD : Electrovanne évac. condensat
F
Chute de pression dans Le point de rosée est trop bas - la condensation a congelé et l’air ne peut
le sécheur trop élevée. pas passer - voir paragraphe spécifique.
Les tuyaux flexibles de raccordement sont étranglés - les contrôler.
Point de rosée trop bas. DMC11 - Vérifier le câblage électrique du DMC11.
ADS93 - V Vérifier le câblage électrique du ADS93.
Vérifier les câbles électriques de l’électrovanne by-pass gaz chaud.
La bobine de l’électrovanne by-pass gaz chaud est brûlée - la remplacer.
DMC11 - La sonde (point de rosée) de l’instrument électronique DMC11 ne
mesure pas correctement la température dans l’évaporateur - pousser la
sonde jusqu’à atteindre le fond du puisard.
ADS93 - La sonde (point de rosée) de l’instrument électronique ADS93 ne
mesure pas correctement la température dans l’évaporateur - pousser la
sonde jusqu’à atteindre le fond du puisard.
DMC11 - Le DMC11 est réglé à un set-point trop bas - voir paragraphe SET-
UP du DMC11.
ADS93 - Le ADS93 est réglé à un set-point trop bas - voir paragraphe SET-
UP du ADS93.
DMC11 - DMC11 est en panne - le remplacer.
ADS93 - ADS93 est en panne - le remplacer.
L’électrovanne by-pass gaz chaud s’est coincée - contacter un technicien
frigoriste.
Modèle DFE
115/1/60 230/1/60
DESCRIPTION CODE 3 5 8 11 18 23 3 5 8 11 18 23
Filtre Y évacuation condensat 64355FF011 1 1 1 1 1 1 1 1 1 1 1 1
Moteur ventilateur 5210135005 1 1
Moteur ventilateur 5210135010 1 1 1 1
Moteur ventilateur 5210110005 1 1
Moteur ventilateur 5210110011 1 1 1 1
Ventilateur moteur ventilateur 5215000010 1 1 1 1
Ventilateur moteur ventilateur 5215000019 1 1 1 1 1 1 1 1
Grille ventilateur 5225000010 1 1 1 1 1 1 1 1
DMC11 Air Dryer Controller 115V 5620130100 1 1 1 1 1 1
DMC11 Air Dryer Controller 230V 5620110100 1 1 1 1 1 1
Sonde DMC11 5625NNN020 1 1 1 1 1 1 1 1 1 1 1 1
Electrovanne évacuation cond. 64320FF005 1 1 1 1 1 1 1 1 1 1 1 1
Bobine 115V 64N22MM035 1 1 1 1 1 1
Bobine 230V 64N22MM005 1 1 1 1 1 1
Electrovanne by-pass 64120SS005 1 1 1 1 1 1
Electrovanne by-pass 64120SS010 1 1 1 1 1 1
Bobine électrov. by-pass 115V 64N22MM055 1 1 1 1 1 1
Bobine électrov. by-pass 230V 64N22MM060 1 1 1 1 1 1
Interrupteur lumineux 2P 0/1 5450SZN005 1 1 1 1 1 1 1 1 1 1 1 1
Interrupteur automatique 5A 54441K7005 2 2 2 2 2 2
Interrupteur automatique 10A 54441K7010 2 2 2 2 2 2
Compresseur frigorifique 5015135001 1
Compresseur frigorifique 5015135003 1
Compresseur frigorifique 5015135005 1
Compresseur frigorifique 5015135007 1
Compresseur frigorifique 5015135009 1
Compresseur frigorifique 5015135011 1
Compresseur frigorifique 5015110001 1
Compresseur frigorifique 5015110004 1
Compresseur frigorifique 5015110007 1
Compresseur frigorifique 5015110109 1
Compresseur frigorifique 5015115010 1
Compresseur frigorifique 5015115011 1
Pièce détachée conseillée.
REMARQUE : Pour commander les pièces détachées conseillées ou tout autre pièce, il est
indispensable de préciser les données figurant sur la plaque d’identification.
F
Modèle DFE
115/1/60 230/1/60
DESCRIPTION CODE 31 43 52 31 43 52 61 75 98 118
Filtre Y évacuation condensat 64355FF011 1 1 1 1 1 1 1 1 2 2
Moteur ventilateur 5210135015 1 1
Moteur ventilateur 5210135021 1
Moteur ventilateur 5210110017 1 1
Moteur ventilateur 5210110022 1 1 1
Ventilateur moteur ventilateur 5215000025 1 1 1 1
Ventilateur moteur ventilateur 5215000034 1 1 1 1
Grille ventilateur 5225000027 1 1 1 1
Grille ventilateur 5225000030 1 1 1 1
Ventilateur 5250110071 1 1
DMC11 Air Dryer Controller 115V 5620130100 1 1 1
ADS93 Controller 230V 5620110001 1 1 1 1 1 1 1
Sonde DMC11 5625NNN020 1 1 1
Sonde ADS93 5625NNN021 1 1 1 1 1
Sonde ADS93 5625NNN023 1 1 1 1 1 1 1
Sonde ADS93 (DewPoint) 5625NNN025 1 1
Electrovanne évacuation cond. 64320FF011 1 1 1 1 1 1 1 1 2 2
Bobine 115V 64N22MM018 1 1 1
Bobine 230V 64N22MM021 1 1 1 1 1 2 2
Electrovanne by-pass 64120SS010 1 1
Electrovanne by-pass 64120SS015 1 1 1 1 1 1 1 1
Bobine électrov. by-pass 115V 64N22MM055 1 1 1
Bobine électrov. by-pass 230V 64N22MM060 1 1 1 1 1 1 1
Interrupteur lumineux 2P 0/1 5450SZN005 1 1 1 1 1 1 1 1
Sectionneur général 5450SZN115 1 1
Interrupteur automatique 5A 54441K7005 2 2 2 2 2 2 2
Interrupteur automatique 10A 54441K7010 2 2 2 2 2 2 2
Compresseur frigorifique 5015135020 1
Compresseur frigorifique 5015135023 1
Compresseur frigorifique 5015135026 1
Compresseur frigorifique 5015115020 1
Compresseur frigorifique 5015115023 1
Compresseur frigorifique 5015115026 1
Compresseur frigorifique 5015115029 1 1 1 1
Vanne thermostatique 64130SS100 1 1
Pressostat gaz réfrigérant PV 5655NNN150 1 1 1
Pressostat gaz réfrigérant PA 5655NNN092 1
Pressostat gaz réfrigérant PA - PB 5655NNN095 1 1
1 2 3
DFE 75 DFE 98-118 230/1/60
4
115/1/60 DFE 31÷52
GB GB
F F
7.1.1 DFE 3-5
7.1.2 DFE 8÷23
7.1.3 DFE 31
7.1.4 DFE 43
7.1.5 DFE 52-61
7.1.6 DFE 75