Power Supplies and UPS
Power Supplies and UPS
Power Supplies and UPS
2020/2021
Power for superior system availability
Our POWER products supply your applications with leading technology and high
quality. Power supplies, DC/DC converters, redundancy modules, and uninterruptible
power supplies are tailored in terms of their functionality and design to the demands of
various different industries.
With our QUINT, TRIO, UNO, and STEP product families, you are equipped to handle
competitors on an international scale.
2 PHOENIX CONTACT
Contents
Power supplies for every application 4
QUINT POWER 8
TRIO POWER 16
Device circuit breakers 18
TRIO CROSS POWER 20
UNO POWER 22
STEP POWER 24
DC/DC converters 28
QUINT DC/DC converters 30
MINI DC/DC converters 34
TRIO DC/DC converters 35
UNO DC/DC converters 36
Inverters 38
Redundancy modules 42
Active redundancy modules 46
Passive redundancy modules 47
Accessories 74
Approvals 78
COMPLETE line 86
PHOENIX CONTACT 3
Power supplies for every application
Our power supplies are used in a wide variety of sectors and industries. With their
various functionalities, performance classes, and designs, they are the right partner for
your application.
• QUINT POWER: Automotive industry, systems manufacturing, process industry,
ship building
• TRIO POWER: Machine building
• UNO POWER: Electromobility
• STEP POWER: Urban infrastructure, building automation
4 PHOENIX CONTACT
PHOENIX CONTACT 5
Power supplies –
a comparison of your advantages
The product families differ with regard to their design, power, and functionality. Select
your solution here based on the requirements:
• QUINT POWER – powerful, and with maximum functionality
• TRIO POWER – robust with standard functionality
• UNO POWER – compact with basic functionality
• STEP POWER – for building automation
QUINT POWER
STEP UNO TRIO
POWER POWER POWER
<100 W >100 W
Reliable start-up of high loads with the dynamic boost power reserve • • •
Preventive function monitoring reports critical operating states before errors occur • •
* Applies to the following devices: 2904597, 2904598, 2909575, 2909576, 2904605, 2904595
6 PHOENIX CONTACT
TRIO POWER QUINT POWER
UNO POWER
STEP POWER
PHOENIX CONTACT 7
QUINT POWER power supplies
The QUINT POWER power supplies from 1 A to 40 A form the core of our
QUINT portfolio.
With our small, compact QUINT POWER power supplies, we provide you with the
combination of preventive function monitoring and exceptional power reserves in a
compact size.
The powerful QUINT POWER power supplies with SFB Technology, preventive
function monitoring, and configurable settings ensure the availability of your system.
8 PHOENIX CONTACT
PHOENIX CONTACT 9
QUINT POWER power supplies <100 W
Your advantages
Startup of high loads, thanks to dynamic boost
Preventive function monitoring reports critical
operating states before errors occur
High efficiency and long service life with low power
dissipation and low heating
Space savings in the control cabinet, thanks to a
narrow, slim-line design
10 PHOENIX CONTACT
QUINT POWER power supplies >100 W
Designed by PHOENIX CONTACT
PHOENIX CONTACT 11
QUINT POWER <100 W
Input 85 V AC ... 264 V AC 85 V AC ... 264 V AC 85 V AC ... 264 V AC
Input 85 V AC ... 264 V AC 85 V AC ... 264 V AC 85 V AC ... 264 V AC
W x H x D in mm 22.5 x 99 x 90 32 x 99 x 90 45 x 99 x 90
12 PHOENIX CONTACT
QUINT POWER >100 W
QUINT POWER, 1~
85 V AC ... 264 V AC, 85 V AC ... 264 V AC, 85 V AC ... 264 V AC, 85 V AC ... 264 V AC,
Input
90 V DC ... 350 V DC 90 V DC ... 350 V DC 90 V DC ... 350 V DC 90 V DC ... 350 V DC
W x H x D in mm 36 x 130 x 125 50 x 130 x 125 70 x 130 x 125 120 x 130 x 140
QUINT POWER, 3~
3 x 320 V AC ... 550 V AC, 3 x 320 V AC ... 550 V AC, 3 x 320 V AC ... 550 V AC, 3 x 320 V AC ... 550 V AC,
Input 2 x 360 V AC ... 550 V AC, 2 x 360 V AC ... 550 V AC, 2 x 360 V AC ... 550 V AC, 2 x 360 V AC ... 550 V AC,
+/- 300 V DC +/- 260 ... 300 V DC +/- 260 ... 300 V DC +/- 260 ... 300 V DC
W x H x D in mm 36 x 130 x 125 50 x 130 x 125 70 x 130 x 125 120 x 130 x 125
85 V AC ... 264 V AC, 85 V AC ... 264 V AC, 85 V AC ... 264 V AC, 3 x 320 V AC ... 575 V AC,
Input
90 V DC ... 350 V DC 90 V DC ... 350 V DC 90 V DC ... 300 V DC 450 V DC ... 800 V DC
W x H x D in mm 32 x 130 x 125 90 x 130 x 125 180 x 130 x 125 96 x 130 x 176
1 AC / 24 V / 3.5 A 1 AC / 12 V / 20 A 1 AC / 48 V / 20 A 3 AC / 48 V / 20 A
Type QUINT-PS/1AC/24DC/3.5 QUINT-PS/1AC/12DC/20 QUINT-PS/1AC/48DC/20 QUINT-PS/3AC/48DC/20
Order No. 2866747 2866721 2866695 2320827
* Devices with differing functions; additional information is available on the product pages at www.phoenixcontact.com
PHOENIX CONTACT 13
QUINT POWER power supplies >100 W
QUINT POWER Plus version – the power supply for demanding applications
Then QUINT POWER Plus version is the accordance with IEC 61508 and IEC 61511),
solution for demanding applications under thus ensuring maximum operational safety.
extreme ambient conditions.
With a protective coating and ATEX and
With integrated decoupling MOSFET for IECEx approval in accordance with the
1+1 and n+1 redundancy, the Plus version standards IEC 60079-0, IEC 60079-7,
provides symmetrical load distribution and IEC 60079-11, and IEC 60079-15, it can also
increases system availability. Furthermore, be used within potentially explosive areas
errors can be detected early on via of zone 2.
configurable output current signaling
thresholds. At the same time, you save time The Plus version is rounded off with a wide
and space thanks to the reduced wiring temperature range of -40°C to +75°C for
work. use under extreme ambient conditions.
14 PHOENIX CONTACT
QUINT POWER 1~
1-phase, 85 V AC ... 264 V AC, 1-phase, 85 V AC ... 264 V AC, 1-phase, 85 V AC ... 264 V AC, 3-phase, 3 x 320 ... 575 V AC,
Input
90 V DC ... 430 V DC 90 V DC ... 430 V DC 90 V DC ... 430 V DC 450 V DC ... 800 V DC
W x H x D in mm 40 x 130 x 125 60 x 130 x 125 90 x 130 x 125 69 x 130 x 125
1 AC / 24 V / 5 A / CO 1 AC / 24 V / 10 A / CO 1 AC / 24 V / 20 A / CO 3 AC / 24 V / 20 A / CO
Type QUINT-PS/1AC/24DC/5/CO QUINT-PS/1AC/24DC/10/CO QUINT-PS/1AC/24DC/20/CO QUINT-PS/3AC/24DC/20/CO
Order No. 2320908 2320911 2320898 2320924
* Devices with differing functions; additional information is available on the product pages at www.phoenixcontact.com
5-year warranty
If your fourth-generation QUINT POWER
becomes damaged in the first five years
following purchase despite the using
this combination, you will receive a free
replacement.
PHOENIX CONTACT 15
TRIO POWER power supplies
Your advantages
Very cost-effective with time-saving, tool-free Push-in
connection and a slim design
Reliable startup of high loads thanks to the dynamic
power reserve, with 150% of the nominal current for
a maximum of five seconds
Electrically robust with a high electric strength
Mechanically robust with high vibration and shock
resistance
16 PHOENIX CONTACT
TRIO POWER with Push-in connection, 1~
Input 85 ... 264 V AC, 99 ... 275 V DC 85 ... 264 V AC, 99 ... 275 V DC 85 ... 264 V AC, 99 ... 275 V DC 85 ... 264 V AC, 99 ... 275 V DC
W x H x D in mm 30 x 130 x 115 35 x 130 x 115 42 x 130 x 160 68 x 130 x 160
3 x 320 V AC ... 575 V AC, 3 x 320 V AC ... 575 V AC, 3 x 320 V AC... 575 V AC, 3 x 320 V AC ... 575 V AC
Input
2 x 360 V AC ... 575 V AC 2 x 360 V AC ... 575 V AC 2 x 360 V AC ... 575 V AC
W x H x D in mm 35 x 130 x 115 42 x 130 x 160 65 x 130 x 160 110 x 130 x 160
• TRIO-PS-IP67/1AC/24DC/20,
Input: 100 V AC ... 240 V AC
Order No.: 1039830
Input 3 x 320 V AC ... 575 V AC
W x H x D in mm 110 x 130 x 160 • TRIO-PS-IP67/3AC/24DC/20,
Input: 3 x 400 V AC ... 500 V AC
72 V / 14 A Order No.: 1039829
Type TRIO-PS-2G/3AC/72DC/14
Order No. 1076188
PHOENIX CONTACT 17
Power supplies
Your advantages
Suitable device protection for any requirement, thanks
to the comprehensive portfolio
System statuses under control with intelligent analysis
and fault signaling
Easy startup with tool-free connection technology
and intuitive operation
18 PHOENIX CONTACT
Multi-channel electronic circuit breakers
Base element /
Single-channel Single-channel Single-channel
Push-in connection
Nominal current 1 A 6 A 10 A
Type CB E1 24DC/1A NO P CB E1 24DC/6A NO P CB E1 24DC/10A NO P CB 1/6-2/4 PT-BE
Order No. 2800901 2800905 2800907 2800929
Base element /
F1 SFB M1
screw connection
Nominal current 0.5 A 6 A 16 A
Type CB TM1 0.5A F1 P CB TM1 6A SFB P CB TM1 16A M1 P CB 1/10-1/10 UT-BE
Order No. 2800857 2800841 2800856 2801305
PHOENIX CONTACT 19
TRIO CROSS POWER power supplies
Your advantages
Push-in connection enables the quick and easy
snap-on connection of 24 V DC loads
Rapid startup: tool-free mounting and automatic
contacting in just one step (CrossPowerSystem)
Reliable startup of high loads with dynamic boost
Electrically robust with a high electric strength
High degree of flexibility with the wide temperature
range of -25°C … +70°C and device startup at -40°C
20 PHOENIX CONTACT
TRIO CROSS POWER 3~
CrossPowerSystem
The CrossPowerSystem is a new and
open platform for modular and functional
control cabinets. Three-phase devices can
be mounted onto the power distributor
easily via Plug and Play. Time is money, and
this is particularly true in the construction
of machines and systems. Thanks to the
combination of power distribution and
switching devices, mounting on the power
distribution board is now even faster.
Furthermore, the integrated reverse pole
protection prevents errors and ensures even
simpler startup.
PHOENIX CONTACT 21
UNO POWER power supplies
Your advantages
High energy efficiency with an efficiency of up to
94% and with extremely low idling losses of less than
0.3 W
Particularly compact, thanks to high power density
Outdoor installation possible with a wide temperature
range of -25°C to +70°C
22 PHOENIX CONTACT
UNO POWER, 1~
Input 85 V AC ... 264 V AC 85 V AC ... 264 V AC 85 V AC ... 264 V AC
W x H x D in mm 22.5 x 90 x 84 35 x 90 x 84 55 x 90 x 84
Input 85 V AC ... 264 V AC 85 V AC ... 264 V AC 85 V AC ... 264 V AC 264 V AC ... 575 V AC
W x H x D in mm 37 x 130 x 125 45 x 130 x 125 59 x 130 x 125 55 x 90 x 84
* NEC Class 2 output, certified in accordance with UL 1310 / Limited Power Source (LPS) in accordance with UL 60950-1
** Can be used in household applications in accordance with EN 60335
PHOENIX CONTACT 23
STEP POWER power supplies
Your advantages
Energy savings with efficiency in no-load and part-load
operation (Efficiency Level VI)
Space savings in the control cabinet with the narrow
design, combined with increased power (up to 100%)
Approval for household purposes (EN 60335) enables
use in domestic applications for the first time, built
into in horizontal pitches (DIN 43880)
Quick and easy startup with tool-free Push-in
connection technology at a 45° angle with double
terminal points
24 PHOENIX CONTACT
Efficiency standards for external power supplies
The new generation of the STEP POWER The new power supplies of the In no-load operation, the no-load losses
power supplies satisfy the currently highest STEP POWER family currently have the of all STEP POWER power supplies are
efficiency standard requirements. With the highest efficiencies on the market. below 0.1 W or 0.21 W depending on
combination of very high efficiencies and • Efficiency during normal operation: performance class, and are therefore setting
low no-load losses, the power supplies are >94.5% new standards.
the first DIN rail devices in the world rated • Efficiency during part-load operation:
with Efficiency Level VI. >90%
Back in the 1990s, the efficiency of external With the new 5 A power supply, a device is
power supply units was just 50%. This now available that provides twice the power
prompted the United States Environmental compared to previous power supplies with
Protection Agency to develop a voluntary an identical overall width (four horizontal
program to promote energy efficiency and pitches).
reduce pollution in 1992. However, it was
only in 2004 that the first regulations were
developed with minimum requirements [%] STEP-PS/1AC/24DC/5/PT
on efficiency and load-free electricity 96
consumption. A great deal has happened
since then, and efforts are continually being 94
made to significantly reduce the energy
consumption of external power supply units.
92
The result of these efforts, Efficiency Level
VI, currently places the highest demands on
energy efficiency. 90
Efficiency
80 [%]
0 20 40 60 80 100 120
PHOENIX CONTACT 25
STEP POWER with household approval (EN 60335)
STEP POWER, 1~
100 V AC ... 240 V AC 100 V AC ... 240 V AC 100 V AC ... 240 V AC 100 V AC ... 240 V AC
Input
110 V DC ... 250 V DC 110 V DC ... 250 V DC 110 V DC ... 250 V DC 110 V DC ... 250 V DC
W x H x D in mm 18 x 90 x 55 36 x 90 x 55 54 x 90 x 55 72 x 90 x 55
26 PHOENIX CONTACT
STEP POWER
STEP POWER, 1~
Shallow
design
85 V AC ... 264 V AC 85 V AC ... 264 V AC 85 V AC ... 264 V AC 85 V AC ... 264 V AC
Input
95 V DC ... 250 V DC 95 V DC ... 250 V DC 95 V DC ... 250 V DC 95 V DC ... 250 V DC
W x H x D in mm 18 x 90 x 61 36 x 90 x 43 36 x 90 x 61 54 x 90 x 61
85 V AC ... 264 V AC 85 V AC ... 264 V AC 43 V AC ... 52 V AC 85 V AC ... 305 V AC
Input
95 V DC ... 250 V DC 95 V DC ... 250 V DC 60 V DC ... 80 V DC 95 V DC ... 250 V DC
W x H x D in mm 72 x 90 x 61 90 x 90 x 61 18 x 90 x 61 90 x 90 x 61
PHOENIX CONTACT 27
DC/DC converters
For a regulated direct voltage
Avoid disturbances in your application by using DC/DC converters. The load is
always supplied with a regulated direct voltage, even when using long cable lengths.
Phoenix Contact provides:
• DC/DC converters with SFB Technology and for extreme demands
• DC/DC converters for control technology
• DC/DC converters for photovoltaic applications
28 PHOENIX CONTACT
PHOENIX CONTACT 29
QUINT DC/DC converters
Adapt voltages
DC/DC converters provide a regulated direct QUINT DC/DC converters with the connection technology for the new
voltage. They regenerate voltages so that the SFB Technology, preventive function generation.
load is always supplied with a regulated DC monitoring, long service life, and IECEx
Web code: #0152
voltage, even in the case of long cable lengths. approval increase the availability of your
Furthermore, the electrical isolation ensures application. Furthermore, the dynamic
the establishment of independent supply boost feature allows high loads to be
systems. started. In addition, you are free to choose
Your advantages
SFB Technology selectively triggers standard circuit
breakers; loads connected in parallel continue working
without interruption
Preventive function monitoring reports critical
operating states before errors occur
Power reserve for easy system extension with a static
boost with a sustained power of up to 125% and the
ability to start heavy loads with a dynamic boost of up
to 200% for five seconds
Free selection between Push-in and screw connection
30 PHOENIX CONTACT
Plus version for extreme ambient conditions
The Plus version of the DC/DC converter The new Plus version is rounded out with a
with integrated decoupling MOSFET for 1+1 wide temperature range of -40°C to +70°C
and n+1 redundancy provides symmetrical for use under extreme ambient conditions.
load distribution and increases system
availability. Furthermore, it satisfies the The protective PCB coating (CO stands
requirements for functional safety (SIL 2). for coated) protects against dust, corrosive
gases, and also against 100% humidity.
With a protective coating, and ATEX Failures due to creepage currents and
and IECEx approval in accordance with electrochemical migration caused by
the standards IEC 60079-0, IEC 60079-7, corrosion are also prevented.
IEC 60079-11, and IEC 60079-15, it can also
be used within potentially explosive areas
of zone 2.
PHOENIX CONTACT 31
QUINT DC/DC converters
Input 18 V DC ... 32 V DC 18 V DC ... 32 V DC 18 V DC ... 32 V DC
W x H x D in mm 36 x 130 x 125 50 x 130 x 125 70 x 130 x 125
Input 18 V DC ... 32 V DC 29 V DC ... 57.5 V DC 18 V DC ... 32 V DC 29 V DC ... 57.5 V DC
W x H x D in mm 36 x 130 x 125 36 x 130 x 125 50 x 130 x 125 50 x 130 x 125
24 V / 12 V / 8 A 48 V / 24 V / 5 A 24 V / 48 V / 5 A New 48 V / 48 V / 5 A New
QUINT4-PS/ QUINT4-PS/ QUINT4-PS/ QUINT4-PS/
Type
24DC/12DC/8/PT 48DC/24DC/5/PT 24DC/48DC/5/PT 48DC/48DC/5/PT
Order No. 2910122 2910125 2910123 2910128
Input 18 V DC ... 32 V DC 18 V DC ... 32 V DC 18 V DC ... 32 V DC 18 V DC ... 32 V DC
W x H x D in mm 36 x 130 x 125 50 x 130 x 125 70 x 130 x 125 70 x 130 x 125
32 PHOENIX CONTACT
QUINT DC/DC converters*
12 V/24 V/5 A 12 V/12 V/8 A
QUINT-PS/ QUINT-PS/
Type
12DC/24DC/5 12DC/12DC/8
Order No. 2320131 2905007
Input 42 V DC ... 96 V DC 67.2 V DC ... 154 V DC 42 V DC ... 96 V DC 67.2 V DC ... 154 V DC
W x H x D in mm 48 x 130 x 125 48 x 130 x 125 48 x 130 x 125 48 x 130 x 125
60 V ... 72 V / 24 V / 10 A 96 V ... 110 V / 24 V / 10 A 60 V ... 72 V / 24 V / 10 A / CO 96 V ... 110 V / 24 V / 10 A / CO
QUINT-PS/ QUINT-PS/ QUINT-PS/ QUINT-PS/
Type
60-72 DC/24DC/10 96-110 DC/24DC/10 60-72 DC/24DC/10/CO 96-110 DC/24DC/10/CO
Order No. 2905009 2905010 2905011 2905012
Input 18 V DC ... 32 V DC 18 V DC ... 32 V DC 18 V DC ... 32 V DC
W x H x D in mm 32 x 130 x 125 48 x 130 x 125 82 x 130 x 125
PHOENIX CONTACT 33
MINI DC/DC converters
Input
12 V DC … 24 V DC 48 V DC … 60 V DC
(10 V DC … 32 V DC) (36 V DC … 75 V DC)
5 V DC … 15 V DC 24 V DC 48 V DC
(5 V DC … 15 V DC) (22.5 V DC … 28.5 V DC) (30 V DC … 56 V DC)
Output
Input 10 V DC ... 32 V DC 10 V DC ... 32 V DC 36 ... 75 V DC / 10 ... 32 V DC 1-phase, 10 V DC ... 42 V AC
W x H x D in mm 22.5 x 99 x 107 22.5 x 99 x 107 22.5 x 99 x 107 22.5 x 99 x 107
34 PHOENIX CONTACT
TRIO DC/DC converters
Your advantages
Specifically developed for the
high DC voltages of photovoltaic
systems
Suitable for use in all photovoltaic
systems with high input voltage
due to conformity with standard
UL 62109; supports potential-free
grounding
In photovoltaic systems, the
central inverter can be started
without an additional AC
connection
High system availability due to the
robust design
Quick and easy installation with
Push-in connection
Type TRIO-PS-2G/1500DC/24DC/8
Order No. 1075240
PHOENIX CONTACT 35
UNO DC/DC converters
Your advantages
Wide input voltage range of 300 V DC … 1000 V DC
Direct field installation possible; an AC connection is
no longer necessary
Simplified approval of the overall system, thanks to
UL 1741 certification for the DC/DC converter
Low space requirement in the control box, thanks to
the compact design and a high degree of efficiency
Simplified startup, thanks to LED function monitoring
36 PHOENIX CONTACT
UNO DC/DC converters
In the application shown, the Combiner Box is connected UNO POWER devices allow direct connection to string In a further expansion stage, the signal line can be replaced
to a supply line (red, e.g. 230 V AC) and a signal line (black). voltages of up to 1000 V DC. This means that the by a wireless connection.
Laying the lines involves significant installation costs. Combiner Box is supplied directly from the photovoltaic
panel, and additional installation costs are not incurred.
PHOENIX CONTACT 37
Inverters for converting direct current into
alternating current
The QUINT inverter reliably converts direct current into alternating current.
The inverter from Phoenix Contact provides:
• A pure sine curve
• Electricity with a constant high quality, without dangerous voltage fluctuations
• Trouble-free supply of voltage-sensitive loads
38 PHOENIX CONTACT
PHOENIX CONTACT 39
QUINT inverters
Your advantages
Manual selection of AC output voltage via a signal
terminal enables use worldwide
A pure sine curve at the output
USB interface for connection to industrial PCs, for
example
Can be switched in parallel for various applications
Space savings, thanks to compact design
40 PHOENIX CONTACT
QUINT DC/AC inverters
L / N / PE
e.g. 230 V AC
24 V DC
PE
L1 / L2 / L3
e.g. 400 V AC
PHOENIX CONTACT 41
Redundancy modules
Redundant power supply solutions are necessary in applications with the highest
demands on operational safety. They ensure that the failure of one power supply unit
does not result in system downtime.
A redundant system is the result of the parallel connection of two power supply units
that are decoupled from one another. This decoupling via an active redundancy module
or a simple diode ensures the high availability and productivity of your system.
42 PHOENIX CONTACT
PHOENIX CONTACT 43
Redundancy modules
Your advantages
Consistent redundancy through to the load
Constant monitoring of input voltage and decoupling
path
Energy savings of 70% with decoupling with MOSFET
Protection against overvoltages at the output
(overvoltage protection) increases the operational
safety
Protective coating with ATEX and IECEx approval for
extreme ambient conditions
44 PHOENIX CONTACT
QUINT ORING with ACB Technology (Auto Current Balancing)
• Even load distribution for redundant The ACB Technology extends the service lower level of power dissipation ensures
power supplies life of redundantly operated power supplies that all the control cabinet components stay
• Lower thermal load on both power by evenly utilizing the power supply units. cooler and the service life of devices in the
supplies As a result of asymmetries, the load is often redundant system is doubled.
• Service life of the redundant solution is supplied by just one power supply unit,
doubled while the other power supply unit runs in
no-load operation. This results in a thermal
load on the working power supply unit and,
therefore, rapid aging. Thanks to the use of
modern MOSFET technology, the resulting
thermal load is reduced by up to 70%. This
Designed by PHOENIX CONTACT
IN1 IN2
Input DC 24V 2x10A
IOUT= 5 A
OK
soon as a set value is exceeded. If the user supplies fails, the second device is no longer Redundancy
OK
Redundancy OK
connects additional loads to a redundant able to provide 8 A. The LED immediately
QUINT ORING
I<In
10A
In
power supply as part of a system extension, warns the system operator that there is no
5A 20A
Output DC 20A
IN1 IN2
Input DC 24V 2x10A
Redundancy
OK
not OK
I<In
10A
In
5A 20A
PHOENIX CONTACT 45
Active redundancy modules
Our 1- or 2-channel active redundancy AC feed-in to the the DC load. By continually reduces the thermal loads due to self-heating
module versions monitor themselves and monitoring the AC and DC voltage levels, to a minimum.
the connection wiring through to the load. the respective wiring, and at the same time,
In combination with a QUINT POWER the decoupling of the load current, critical
supply, you can extend the system to include operating states can be detected and signaled
complete redundancy monitoring from the early on. The integrated MOSFET technology
QUINT S-ORING
Input 8 V DC ... 30 V DC 8 V DC ... 27.5 V DC 8 V DC ... 26 V DC
W x H x D in mm 32 x 130 x 125 32 x 130 x 125 32 x 130 x 125
12 V … 24 V / 1 x 40 A 12 V … 24 V / 1 x 40 A /VP* 12 V … 24 V / 1 x 40 A / +**
Type QUINT4-ORING/12-24DC/1x40 QUINT4-S-ORING/12-24DC/1x40/VP QUINT4-ORING/12-24DC/1x40/+
Order No. 2907752 1043418 2907753
* Overvoltages arising are limited to 30 V, ** overvoltages arising are limited to 28.8 V
Input 18 V DC ... 28 V DC 18 V DC ... 28 V DC 18 V DC ... 28 V DC
W x H x D in mm 32 x 130 x 125 38 x 130 x 125 66 x 130 x 125
46 PHOENIX CONTACT
Passive redundancy modules
Passive redundancy modules enable simple second power supply automatically takes over connecting cables through to the DC load are
decoupling of two power supplies on the the entire supply for the DC load. The diode not monitored.
DC side. This is useful in particular when power losses arising during operation are
power supplies are connected in parallel to dissipated completely as thermal energy to
increase power or for redundancy purposes. the control cabinet. The diode is not subject
If one device fails due to malfunctions, the to preventive function monitoring, and the
Power supply 2
QUINT DIODE
Input 10 V DC ... 30 V DC 10 V DC ... 30 V DC 4.5 V DC ... 30 V DC 4.5 V DC ... 30 V DC
W x H x D in mm 35 x 130 x 115 41 x 130 x 115 22.5 x 90 x 84 18 x 90 x 61
12 V … 24 V / 2 x 10 A / 12 V … 24 V / 2 x 20 A / 5 V … 24 V / 2 x 10 A / 5 V … 24 V / 2 x 5 A /
1 x 20 A 1 x 40 A 1 x 20 A 1 x 10 A
TRIO2-DIODE/ TRIO2-DIODE/ UNO-DIODE/ STEP-DIODE/
Type
12-24DC/2x10/1x20 12-24DC/2x20/1x40 5-24DC/2x10/1x20 5-24DC/2x5/1x10
Order No. 2907380 2907379 2905489 2868606
Monitored
Not monitored
PHOENIX CONTACT 47
Uninterruptible power supplies
Mains interruptions can have serious consequences. Do not take any risks. You can rely
on our uninterruptible power supplies.
We provide the following solutions for high system availability, even in the event of a
mains failure:
• DC and AC UPS modules with communication interfaces
• UPS modules with integrated power supply or energy storage system
• Comprehensive selection of energy storage systems
48 PHOENIX CONTACT
PHOENIX CONTACT 49
Uninterruptible power supplies
IQ Technology
Designed by PHOENIX CONTACT
50 PHOENIX CONTACT
Intelligent charging
Intelligent battery management
Adapts the charging current and
SOC (State of Charge)
thereby ensures fast recharging and
Describes the current state of charge and the
availability.
remaining energy storage system runtime.
PHOENIX CONTACT 51
QUINT DC UPS uninterruptible power
supplies – intelligent and communicative
With the intelligent QUINT DC UPS for integration into existing industrial networks,
you are ready for Industrie 4.0. With the QUINT DC UPS and the integrated
interfaces for PROFINET, EtherNet/IP™, EtherCAT®, and USB, monitoring,
configuration, and shutting the system down in a safe state are possible at all times and
anywhere in the world.
52 PHOENIX CONTACT
The first intelligent QUINT DC UPS for integration into established industrial networks
Interfaces Extended load management
The QUINT DC-UPS can be easily The extended load management system
integrated into the following existing consists of the following functions:
industrial networks via various interfaces: • Energy monitoring – monitoring input
• PROFINET and output voltages and the associated
• EtherNet/IP™ currents
• EtherCAT® • PC shutdown function – reliable
shutdown of your industrial PC in the
All network technologies, devices with USB event of a mains failure without data loss,
interface, and devices without an interface and automatic restart of the industrial PC
are available in all four performance classes when the mains power returns
(5 A, 10 A, 20 A, and 40 A). • Cold-start function – UPS startup even
without mains power
2-port switch Device descriptions
Our QUINT DC UPS has a 2-port switch. Function blocks If the appropriate function block for your
The device can therefore be integrated We include the corresponding function application is not available, you can create
flexibly into existing industrial networks. blocks for the following engineering your own custom function blocks using our
environments so that the QUINT DC UPS device descriptions.
can be started up quickly:
• PLCnext
• TIA Portal
• Studio 5000
• TwinCAT
PHOENIX CONTACT 53
Uninterruptible power supplies
54 PHOENIX CONTACT
~ ~ ~ + –+ –+ –
PHOENIX CONTACT 55
Uninterruptible power supplies
IQ Technology
Designed by PHOENIX CONTACT
56 PHOENIX CONTACT
Seamless transition, thanks to online Comprehensive signaling and
topology configuration
• Classification in accordance with • Floating relay contacts
EN 62040-3: VFI-SS-111 • Signal contacts
Convection cooling
• Fan-free heat dissipation
USB interface
• For connection to industrial PCs
and controllers
PHOENIX CONTACT 57
Uninterruptible power supplies
Your advantages
Fast installation thanks to automatic detection of
the energy storage system and tool-free replacement
during operation
Constant communication with QUINT UPS for
continuous monitoring and intelligent management
Extremely long service life with optimized charging
characteristics based on the technology and the
ambient conditions UPS-BAT/LI-ION...
Immediate availability: all energy storage systems leave • Long service life with long buffer times
our warehouse fully charged • Lithium iron phosphate technology
58 PHOENIX CONTACT
Typical Service life Service life Charging cycles Weight
Type Temperature
buffer time at +20°C at +50°C at +20°C (standardized)
UPS-BAT/LI-ION… >40 min -20°C ... +58°C 15 years 2 years 7,000 0.45 kg
UPS-BAT/VRLA-WTR… >5 h -25°C ... +60°C 12 years 1.5 years 300 1.3 kg
UPS-BAT/VRLA… >8 h 0°C ... +40°C 6 years … 9 years 1 year 250 1 kg
UPS-BAT/VRLA-WTR... UPS-BAT/VRLA...
(Valve Regulated Lead Acid / (Valve Regulated Lead Acid)
Wide Temperature Range) • Longer buffer times
• Longer buffer times at extreme • Lead AGM technology (Absorbent
temperatures Glass Mat)
• Pure lead AGM technology (Absorbent
Glass Mat)
PHOENIX CONTACT 59
Uninterruptible power supplies
Your advantages
Evaluation of the state of health (SOH) and state
of charge (SOC), thanks to the intelligent battery
management system (BMS)
Automatic recognition of the battery capacities and
technologies (VRLA, WTR, LiFePO4)
Monitoring of output current and voltage, as well as
manual connection and disconnection of the system
SFB Technology selectively trips standard miniature
circuit breakers; loads connected in parallel continue
working
60 PHOENIX CONTACT
QUINT DC UPS* IQ Technology
Designed by PHOENIX CONTACT
QUINT CHARGER
QUINT DC UPS* IQ Technology
Additional charger for increasing the charging
with dual output Designed by PHOENIX CONTACT
current
PHOENIX CONTACT 61
Selection guide for QUINT DC UPS and energy storage system
Select the appropriate combination of QUINT DC UPS and energy storage system here.
~ + –
UPS-BAT/LI-ION UPS-BAT/VRLA-WTR
+ –
W x H x D in mm 135 x 202 x 110 264 x 224 x 197 172 x 177 x 178 358 x 174 x 169
Buffer times for your QUINT DC UPS with the following energy storage systems: LI-ION, and VRLA-WTR
62 PHOENIX CONTACT
IQ Technology … with dual
QUINT DC UPS Designed by PHOENIX CONTACT output
~ + –
W x H x D in mm 35 x 130 x 125 35 x 130 x 125 40 x 130 x 125 47 x 130 x 125 35 x 130 x 125
24 V / 5 A 24 V / 10 A 24 V / 20 A 24 V / 40 A 12 V / 5 A; 24 V / 10 A
QUINT4-UPS QUINT4-UPS QUINT4-UPS QUINT4-UPS QUINT-UPS
Type
24DC/24DC/5... 24DC/24DC/10... 24DC/24DC/20... 24DC/24DC/40... 24DC/12DC/5/24DC/10
Recommended LI-ION LI-ION LI-ION LI-ION 924WH
LI-ION
energy storage VRLA-WTR VRLA-WTR VRLA-WTR VRLA-WTR
VRLA/1.3 ... 38 AH
system VRLA/1.3 ... 12 AH VRLA/1.3 ... 38 AH VRLA/3.4 ... 38 AH VRLA/7.2 ... 38 AH
(max. 60 AH)
UPS-BAT/... (max. 40 AH) (max. 80 AH) (max. 100 AH) (max. 100 AH)
UPS-BAT/VRLA
+ –
W x H x D in mm 54 x 157 x 113 85 x 191 x 110 135 x 202 x 110 202 x 202 x 110 152 x 167 x 181 330 x 221 x 197
Buffer times for your QUINT DC UPS with VRLA energy storage systems
PHOENIX CONTACT 63
Selection guide for QUINT AC-UPS/500VA and energy storage system
Select the appropriate combination of QUINT AC-UPS/500VA and energy storage system here.
~ + –
UPS-BAT/LI-ION UPS-BAT/VRLA-WTR
+ –
W x H x D in mm 135 x 202 x 110 264 x 224 x 197 172 x 177 x 178 358 x 174 x 169
Buffer times for your QUINT AC-UPS/500VA with the following energy storage systems: LI-ION, and
VRLA-WTR
Select your energy storage system for Buffer time
your QUINT AC-UPS/500VA (120 / 230 V Seconds Minutes Hours
application). Power 0.2 0.4 2 8 15 20 40 1 2 3 5 10 20 30 40 45 50 1 2 3 5 8 10 15 20
Example: 125 W is to be buffered for one 15 W 1+1
hour. 35 W 1+1 1+1
55 W 1+1 1+1
90 W 1+1 1+1
125 W 1+1 1+1 1+1
180 W 1+1 1+1
275 W 1+1 1+1
400 W 1+1 1+1
QUINT4-UPS/1AC/1AC/500VA/USB
and UPS-BAT/VRLA-WTR/24DC/26AH 1+1: Two energy storage systems of the same capacity are required in this case. The data is based on an
ambient temperature of +20°C.
64 PHOENIX CONTACT
QUINT AC UPS 1~ IQ Technology Accessories Web code: #1988
Designed by PHOENIX CONTACT
~ + –
Recommended
LI-ION For communication between the UPS
energy storage
VRLA-WTR module and the UPS-CONF, length 3 m
system
VRLA/3.4 ... 38 AH
1 x UPS-BAT/...
UPS-BAT/VRLA
+ –
W x H x D in mm 85 x 191 x 110 135 x 202 x 110 202 x 202 x 110 152 x 167 x 181 330 x 221 x 197
Buffer times for QUINT AC-UPS/500VA with VRLA energy storage systems
PHOENIX CONTACT 65
Selection guide for QUINT AC-UPS/1kVA and energy storage system
Select the appropriate combination of QUINT AC-UPS/1kVA and energy storage system here.
~ + –
UPS-BAT/LI-ION UPS-BAT/VRLA-WTR
+ –
W x H x D in mm 135 x 202 x 110 264 x 224 x 197 172 x 177 x 178 358 x 174 x 169
Buffer times for your QUINT AC-UPS/1kVA with the following energy storage systems: LI-ION, and
VRLA-WTR
Select your energy storage system for Buffer time
your QUINT AC-UPS/1kVA (120 / 230 V Minutes Hours
application). Power 2 3 4 5 8 10 15 20 25 30 40 50 1 1.5 2 3 4 6 9 10
Example: 400 W is to be buffered for three 100 W 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1
hours. 200 W 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1
300 W 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1
400 W 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1
500 W 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1
600 W 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1
700 W 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1
800 W 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1
QUINT4-UPS/1AC/1AC/1KVA and 900 W 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1
2 x UPS-BAT/LI-ION/24DC/924WH
1+1: For the QUINT AC-UPS/1kVA, two energy storage systems of the same capacity are always required.
The data is based on an ambient temperature of +20°C.
66 PHOENIX CONTACT
QUINT AC UPS 1~ IQ Technology Accessories Web code: #1988
Designed by PHOENIX CONTACT
~ + –
Recommended
energy storage LI-ION For communication between the UPS
system VRLA-WTR module and the UPS-CONF, length 3 m
2 x UPS-BAT/... VRLA/3.4 ... 38 AH
UPS-BAT/VRLA
+ –
W x H x D in mm 85 x 191 x 110 135 x 202 x 110 202 x 202 x 110 152 x 167 x 181 330 x 221 x 197
Buffer times for your QUINT AC-UPS/1kVA with VRLA energy storage systems:
PHOENIX CONTACT 67
Selection guide for QUINT UPS modules with integrated energy storage system
~ + –
~ + –
Input 22.5 V DC ... 30 V DC 22.5 V DC ... 30 V DC 22.5 V DC ... 30 V DC
W x H x D in mm 85 x 102.5 x 90 94 x 130 x 125 118 x 130 x 125 Length: 3 m
24 DC / 3,8 A New 24 DC / 5 A 24 DC / 10 A USB data cable
QUINT4-CAP/ QUINT4-CAP/ QUINT4-CAP/ MINI-SCREW-USB-
Type
24DC/3.8/1KJ/PT 24DC/5/4KJ 24DC/10/8KJ DATACABLE
Order No. 2320526 2320539 2320571 2908217
68 PHOENIX CONTACT
IQ Technology
QUINT UPS Designed by PHOENIX CONTACT
~ + –
QUINT BUFFER
~ + –
PHOENIX CONTACT 69
Selection guide for UPS modules with integrated energy storage system
~ + –
Energy storage system with Energy storage system with For communication between UPS
Information
lead AGM technology lead AGM technology module and UPS-CONF
70 PHOENIX CONTACT
~ + –
~ + –
Input 23 V DC ... 30 V DC 22.5 V DC ... 29.5 V DC 10 V DC ... 16.5 V DC
W x H x D in mm 110 x 90 x 90 108 x 90 x 61 108 x 90 x 61
PHOENIX CONTACT 71
Selection guide for UPS modules with integrated power supply
~ + –
~ + – ~ + –
72 PHOENIX CONTACT
TRIO DC UPS 1~ TRIO DC UPS 3~ Accessories
~ + –
100 V AC ... 240 V AC, 100 V AC ... 240 V AC, 3 x 400 V AC ... 500 V AC For communication between
Input
110 V DC ... 250 V DC 110 V DC ... 250 V DC 2 x 400 V AC ... 500 V AC the UPS module and the
UPS-CONF, length 3 m
W x H x D in mm 60 x 130 x 115 68 x 130 x 160 88 x 130 x 160
UPS-BAT/VRLA
+ –
W x H x D in mm 85 x 191 x 110 135 x 202 x 110 202 x 202 x 110 152 x 167 x 181 330 x 221 x 197
Buffer times for TRIO DC UPS with VRLA energy storage system
Select your energy storage system for your Load Seconds Minutes Hours
TRIO DC UPS here. current 10 15 30 1 2 3 5 6 7 8 9 10 20 30 40 45 50 1 2 3 5 8 10 15 20
1A
Example: 10 A is to be buffered for
2A 1+1 1+1
10 minutes. 3A 1+1 1+1
5A 1+1 1+1
7A 1+1 1+1
10 A 1+1 1+1
15 A 1+1 1+1
TRIO-UPS-2G/1AC/24DC/10 and 20 A 1+1
UPS-BAT/VRLA/24DC/3.4AH The data is based on an ambient temperature of +20°C.
PHOENIX CONTACT 73
Product overview Accessories
74 PHOENIX CONTACT
Product overview Accessories for uninterruptible power supplies
Programming adapters RS-232 data cable Open End data cable MINI DIN data cable
Type IFS-BT-PROG-ADAPTER IFS-RS232-DATACABLE IFS-OPEN-END-DATACABLE IFS-MINI-DIN-DATACABLE
Order No. 2905872 2320490 2320450 2320487
Description • Bluetooth programming adapter • Modbus communication with • Open cable for flexible • Direct communication with the
for wireless communication RS-232 interface communication Inline controller (ILC) from the
between the UPS module and • COM server from • Length: 2 m Phoenix Contact Inline system
the UPS-CONF Phoenix Contact for Ethernet (100 series)
communication • Length: 2 m
• Address higher-level controllers
such as Inline controllers (ILCs)
or Remote Field Controllers
(RFCs) directly
• Use the Phoenix Contact Inline
controller as a gateway and
access other communication
protocols
• Length: 2 m
FL COMSERVER
Software USB data cable Memory block Memory block
UNI 232/422/485
Type UPS-CONF IFS-USB-DATACABLE IFS-CONFSTICK IFS-CONFSTICK-L
Order No. 2320403 2320500 2986122 2901103 2313452
Description • Available free-of-charge • For communication • For saving and • For saving and • Integration of serial RS-
on the Phoenix Contact between the UPS transferring configured transferring configured 232, RS-422, and
website under module and the UPS- values to other values to other RS-485 interfaces
“Downloads” on the CONF QUINT UPS modules or QUINT UPS modules or • For machine and system
access via Ethernet
QUINT-UPS/... product • Length: 3 m for use as a service stick for use as a service stick
network
pages • With lock • Without lock
• Can remain in the UPS
PHOENIX CONTACT 75
Accessories for uninterruptible power supplies
FUSE 15 A / 32 V FK1 FUSE 25 A / 32 V ATOF FUSE 30 A / 32 V ATOF
Order No. 2908360 2908366 2908365
Information For: For: For:
UPS-BAT/VRLA/24DC/1.3AH UPS-BAT/VRLA/24DC/3.4AH UPS-BAT/LI-ION/24DC/120WH
UPS-BAT/VRLA/24DC/7.2AH
UPS-BAT/VRLA/24DC/12AH
UPS-BAT/VRLA/24DC/38AH
UPS-BAT/VRLA-WTR/24DC/13AH
UPS-BAT/VRLA-WTR/24DC/26AH
UPS-BAT/LI-ION/24DC/924WH
76 PHOENIX CONTACT
Accessories for uninterruptible power supplies
FUSE 5 A / 32 V FK1 FUSE 15 A / 32 V FKS FUSE 10 A / 32 V FK1 FUSE 25 A / 32 V FKS
Order No. 1104162 2908361 2908364 2908363
Information For: For: For: For:
UNO-UPS/24DC/24DC/60W MINI-BAT/24DC/1.3AH MINI-BAT/12DC/1.6AH MINI-BAT/12DC/2.6AH
Replacement
Replacement battery
Replacement batteries for UPS-BAT/VRLA batteries for UPS-
for UPS-BAT/LI-ION
BAT/VRLA/WTR
PHOENIX CONTACT 77
Approvals for QUINT POWER
UL CSA Ship EX
Division 2, Groups A, B, C, D
LR – Lloyd’s Register
Installation altitude
UL Listed UL 508
Startup at -40°C
DNV GL Group
ATEX/IECEx
DeviceNet™
CB Scheme
EAC-Ex
RINA
EAC
CE
QUINT POWER power supplies with SFB Technology
QUINT4-PS/1AC/24DC/5 2904600 • • • • • • • • • • • • • • c
QUINT4-PS/1AC/24DC/10 2904601 • • • • • • • • • • • • • • • c
QUINT4-PS/1AC/24DC/20 2904602 • • • • • • • • • • • • • • • c
QUINT4-PS/1AC/24DC/20/+ 2904617 • • • • • • • • • • • • • • c
QUINT4-PS/1AC/24DC/40 2904603 • • • • • • * • • • • • c
QUINT-PS/1AC/24DC/3.5 2866747 • • • • • • • • • • • • • • • • • c
QUINT4-PS/1AC/12DC/15 2904608 • • • • • • • * * * • • • • • c
QUINT-PS/1AC/12DC/20 2866721 • • • • • • • • • • • • d
QUINT4-PS/1AC/48DC/5 2904610 • • • • • • • * * * • • • • • c
QUINT4-PS/1AC/48DC/10 2904611 • • • • • • • • • • • • • • • c
QUINT-PS/1AC/48DC/20 2866695 • • • • • • • • • • • d
QUINT4-PS/3AC/24DC/5 2904620 • • • • • • • • • • • • • • • c
QUINT4-PS/3AC/24DC/10 2904621 • • • • • • • • • • • • • • • c
QUINT4-PS/3AC/24DC/20 2904622 • • • • • • • • • • • • • • • c
QUINT4-PS/3AC/24DC/40 2904623 • • • • • • * • • • • • c
QUINT-PS/3AC/48DC/20 2320827 • • • • • • • • • • b
QUINT4-PS/1AC/24DC/10/CO 2904625 • • • • • • • • • • • • • • • c
QUINT4-PS/1AC/48DC/10/CO 2904626 • • • • • • • • • • • • • • • c
QUINT-PS/1AC/24DC/5/CO 2320908 • • • • • • • • • • • • • • • • d
QUINT-PS/1AC/24DC/10/CO 2320911 • • • • • • • • • • • • • • • • • • • • • c
QUINT-PS/1AC/24DC/20/CO 2320898 • • • • • • • • • • • • • • • • d
QUINT-PS/3AC/24DC/20/CO 2320924 • • • • • • • • • • • • c
* Approval in preparation
a) max. 3000 m b) max. 4000 m c) max. 5000 m d) max. 6000 m e) max. 2000 m
All products receive further approvals on a continual basis.
For up-to-date information, please refer to the Phoenix Contact website under “Downloads” on the respective product pages.
78 PHOENIX CONTACT
Approvals for TRIO POWER
UL CSA Ship EX
Division 2, Groups A, B, C, D
cCSAus 61010-2-201
LR – Lloyd’s Register
BV – Bureau Veritas
Installation altitude
UL Listed UL 508
Startup at -40°C
DNV GL Group
DeviceNet™
CB Scheme
IECEx
ATEX
RINA
EAC
CE
PHOENIX CONTACT 79
Approvals for UNO POWER
UL CSA Ship EX
Division 2, Groups A, B, C, D
LR – Lloyd’s Register
BV – Bureau Veritas
Installation altitude
Startup at -40°C
DNV GL Group
DeviceNet™
CB Scheme
PQ Star
MOOP
ATEX
RINA
EAC
CE
* Approval in preparation
a) max. 3000 m b) max. 4000 m c) max. 5000 m d) max. 6000 m e) max. 2000 m
All products receive further approvals on a continual basis.
For up-to-date information, please refer to the Phoenix Contact website under “Downloads” on the respective product pages.
80 PHOENIX CONTACT
Approvals for STEP POWER
UL CSA Ship EX
Division 2, Groups A, B, C, D
LR – Lloyd’s Register
BV – Bureau Veritas
Installation altitude
Startup at -40°C
DNV GL Group
DeviceNet™
CB Scheme
PQ Star
MOOP
ATEX
RINA
EAC
CE
PHOENIX CONTACT 81
Approvals for DC/DC converters
UL CSA Ship EX
Division 2, Groups A, B, C, D
LR – Lloyd’s Register
BV – Bureau Veritas
Installation altitude
Startup at -40°C
DNV GL Group
EN 50121-3-2
ATEX/IECEx
CB Scheme
EAC-Ex
RMRS
RINA
EAC
CE
DC/DC converters
QUINT4-PS/24DC/24DC/5/PT 2910119 • • • • * * * * * • • • • • • c
QUINT4-PS/24DC/24DC/5/SC 1046800 • • • • * * * * * • • • • • • c
QUINT4-PS/24DC/24DC/10/PT 2910120 • • • • * * * * * • • • • • • c
QUINT4-PS/24DC/24DC/10/SC 1046803 • • • • * * * * * • • • • • • c
QUINT4-PS/24DC/24DC/20/PT 2910121 • * * * * * * * • • • • • c
QUINT4-PS/24DC/24DC/20/SC 1046805 • * * * * * * * • • • • • c
QUINT4-PS/24DC/24DC/20/SC/+ 1046881 • * * * * * * * • • • • • c
QUINT4-PS/24DC/12DC/8/PT 2910122 • • • • * * * * * • • • • • • c
QUINT4-PS/24DC/48DC/5/PT 2910123 • * * * * * * *
QUINT4-PS/48DC/24DC/5/PT 2910125 • • • • * * * * * • • • • • • c
QUINT4-PS/48DC/48DC/5/PT 2910128 • * * * * * * *
QUINT-PS/12DC/24DC/5 2320131 • • • • • • • • • • • • • • • d
QUINT-PS/12DC/12DC/8 2905007 • • • • • • • • • d
QUINT-PS/60-72DC/24DC/10 2905009 • • • • • • • • • d
QUINT-PS/96-110DC/24DC/10 2905010 • • • • • • • • • d
QUINT-PS/24DC/24DC/5/CO 2320542 • • • • • • • • • • • • • • • • • • d
QUINT-PS/24DC/24DC/10/CO 2320555 • • • • • • • • • • • • • • • • • • d
QUINT-PS/24DC/24DC/20/CO 2320568 • • • • • • • • • • • • • • • • • d
QUINT-PS/60-72DC/24DC/10/CO 2905011 • • • • • • • • • • d
QUINT-PS/96-110DC/24DC/10/CO 2905012 • • • • • • • • • • d
UNO-PS/350-900DC/24DC/60W 2906300 • • • • c
TRIO-PS-2G/1500DC/24DC/8 1075240 • • • • • b
MINI-PS-12-24DC/24DC/1 2866284 • • • • • • d
MINI-PS-12-24DC/5-15DC/2 2320018 • • • • • • • d
MINI-PS-12-24DC/48DC/0.7 2320021 • • • • • • • d
MINI-PS-48-60DC/24DC/1 2866271 • • • • • d
MINI-PS/10-42AC/15-60DC/3 2320199 • • • • • d
* Approval in preparation
a) max. 3000 m b) max. 4000 m c) max. 5000 m d) max. 6000 m e) max. 2000 m
All products receive further approvals on a continual basis.
For up-to-date information, please refer to the Phoenix Contact website under “Downloads” on the respective product pages.
82 PHOENIX CONTACT
Inverters
Redundancy modules
STEP-DIODE/5-24DC/2x5/1x10
QUINT4-ORING/12-24DC/1x40
QUINT-ORING/24DC/2x40/1x80
QUINT-ORING/24DC/2x20/1x40
QUINT-ORING/24DC/2x10/1x20
UNO-DIODE/5-24DC/2x10/1x20
QUINT4-ORING/12-24DC/1x40/+
QUINT4-DIODE/48DC/2x20/1X40
TRIO2-DIODE/12-24DC/2x20/1x40
TRIO2-DIODE/12-24DC/2x10/1x20
QUINT4-INV/24DC/1AC/600VA/USB
QUINT4-S-ORING/12-24DC/1x40/VP
QUINT4-DIODE/12-24DC/2x20/1X40
2868606
2905489
2907379
2907380
2907720
2907719
2902879
2320186
2320173
1043418
2907753
2907752
1067325
•
•
•
•
•
•
•
•
•
•
•
•
•
CE CE
UL Listed UL 508 * ANSI/UL 61010-1
UL
UL
•
•
•
•
•
•
•
•
•
•
•
•
*
UL/C-UL Listed UL 508 ANSI/UL 61010-2-201
•
•
•
•
•
•
•
•
•
•
•
•
UL/C-UL Recognized UL 60950 UL/C-UL Recognized UL 60950
UL 1778 UL 1778
UL Listed ANSI/ISA-12.12.01 Class I,
•
•
•
•
•
•
•
•
UL 121201 Class I and II, Div 2 and
*
•
•
•
•
•
•
•
DNV GL Group DNV GL Group
Ship
Ship
•
•
•
ABS – American Bureau of Shipping ABS – American Bureau of Shipping
•
•
•
BV – Bureau Veritas BV – Bureau Veritas
•
•
•
LR – Lloyd’s Register LR – Lloyd’s Register
•
•
•
NK – Nippon Kaiji Kyokai NK – Nippon Kaiji Kyokai
•
•
•
RINA RINA
•
•
•
•
•
•
ATEX/IECEx ATEX
EX
EX
•
•
•
•
•
•
EAC-Ex IECEx
DeviceNet™ DeviceNet™
SEMI F47-0706 Compliance Certificate SEMI F47-0706 Compliance Certificate
PQ Star PQ Star
•
•
•
•
•
•
•
•
*
•
•
•
•
•
•
•
•
•
•
•
•
EAC EAC
PHOENIX CONTACT
•
•
•
•
•
•
•
•
•
•
•
•
e
e
e
e
e
e
e
e
e
83
Approvals for uninterruptible power supplies
UL CSA Ship EX
Division 2, Groups A, B, C, D
LR – Lloyd’s Register
BV – Bureau Veritas
Installation altitude
UL Listed UL 508
Startup at -40°C
DNV GL Group
CB Scheme
UL 1778
ATEX
RINA
EAC
CE
Uninterruptible power supplies
QUINT4-UPS/24DC/24DC/5/PN 2906993 • • • * * * * * * • • • b
QUINT4-UPS/24DC/24DC/10/PN 2907068 • • • * * * * * * • • • b
QUINT4-UPS/24DC/24DC/20/PN 2907073 • • • * * * * * * • • • b
QUINT4-UPS/24DC/24DC/40/PN 2907079 • • • * * * * * * • • • b
QUINT4-UPS/24DC/24DC/5/EIP 2906994 • • • * * * * * * • • • b
QUINT4-UPS/24DC/24DC/10/EIP 2907069 • • • * * * * * * • • • b
QUINT4-UPS/24DC/24DC/20/EIP 2907074 • • • * * * * * * • • • b
QUINT4-UPS/24DC/24DC/40/EIP 2907080 • • • * * * * * * • • • b
QUINT4-UPS/24DC/24DC/5/EC 2906996 • • • * * * * * * • • • b
QUINT4-UPS/24DC/24DC/10/EC 2907070 • • • * * * * * * • • • b
QUINT4-UPS/24DC/24DC/20/EC 2907076 • • • * * * * * * • • • b
QUINT4-UPS/24DC/24DC/40/EC 2907081 • • • * * * * * * • • • b
QUINT4-UPS/24DC/24DC/5/USB 2906991 • • • * * * * * * • • • b
QUINT4-UPS/24DC/24DC/10/USB 2907067 • • • * * * * * * • • • b
QUINT4-UPS/24DC/24DC/20/USB 2907072 • • • * * * * * * • • • b
QUINT4-UPS/24DC/24DC/40/USB 2907078 • • • * * * * * * • • • b
QUINT4-UPS/24DC/24DC/5 2906990 • • • * * * * * * • • • b
QUINT4-UPS/24DC/24DC/10 2907066 • • • * * * * * * • • • b
QUINT4-UPS/24DC/24DC/20 2907071 • • • * * * * * * • • • b
QUINT4-UPS/24DC/24DC/40 2907077 • • • * * * * * * • • • b
QUINT4-CHARGER/1AC/24DC/10 2907990 • • •
QUINT-UPS/24DC/12DC/5/24DC/10 2320461 • • • • e
QUINT4-UPS/1AC/1AC/500VA/USB 1067327 • • * * * a
QUINT4-UPS/1AC/1AC/1KVA 2320283 • • • • • • a
TRIO-UPS-2G/1AC/1AC/230V/750VA 2905909 • • • • a
TRIO-UPS-2G/1AC/1AC/120V/750VA 2905908 • • • • a
QUINT-UPS/24DC/24DC/5/1.3AH 2320254 • • • • • d
QUINT-UPS/24DC/24DC/10/3.4AH 2320267 • • • • • d
QUINT4-BUFFER/24DC/24DC/20 2907913 • • • • • • • • b
QUINT4-BUFFER/24DC/24DC/40 2909283 • • • • • • • • b
QUINT4-CAP/24DC/3.8/1KJ/PT 2320526 • • • • •
QUINT4-CAP/24DC/5/4KJ 2320539 • • • • • • • • b
QUINT4-CAP/24DC/10/8KJ 2320571 • • • • • • • • b
UNO-UPS/24DC/24DC/60W 2905907 • • • • e
STEP-UPS/24DC/24DC/3/46WH 1081430 • • • • • e
STEP-UPS/12DC/12DC/4/46WH 1082548 • • • • • e
* Approval in preparation
a) max. 3000 m b) max. 4000 m c) max. 5000 m d) max. 6000 m e) max. 2000 m
All products receive further approvals on a continual basis.
For up-to-date information, please refer to the Phoenix Contact website under “Downloads” on the respective product pages.
84 PHOENIX CONTACT
Approvals for energy storage systems
UL CSA Ship EX
Division 2, Groups A, B, C, D
LR – Lloyd’s Register
BV – Bureau Veritas
Installation altitude
UL Listed UL 508
Startup at -40°C
DNV GL Group
CB Scheme
UL 1778
ATEX
RINA
EAC
CE
Uninterruptible power supplies
TRIO-UPS-2G/1AC/24DC/5 2907160 • • • * • • d
TRIO-UPS-2G/1AC/24DC/10 2907161 • • • * • • d
TRIO-UPS-2G/3AC/24DC/20 2906367 • • • * • • d
MINI-DC-UPS/24DC/2 2866640 • • • • • c
MINI-DC-UPS/12DC/4 2866598 • • • • • • d
UL CSA Ship EX
Division 2, Groups A, B, C, D
LR – Lloyd’s Register
BV – Bureau Veritas
Installation altitude
UL Listed UL 508
Startup at -40°C
DNV GL Group
CB Scheme
DeviceNet
UL 1778
PQ Star
IECEx
ATEX
RINA
EAC
CE
PHOENIX CONTACT 85
COMPLETE line
The comprehensive solution for the control
cabinet
COMPLETE line is a system comprised of technologically leading and coordinated
hardware and software products, consulting services, and system solutions that help
you optimize your processes in control cabinet manufacturing. Engineering, purchasing,
installation, and operation become significantly easier for you.
86 PHOENIX CONTACT
Your advantages in detail:
Comprehensive product portfolio Intuitive handling Save time throughout the entire
With COMPLETE line, we offer a complete Thanks to the simple, intuitive handling of engineering process
product portfolio of technologically leading the coordinated hardware components, you The PROJECT complete planning and marking
products. This includes: will save time during installation, startup, software supports the entire process of
• Controllers and I/O modules and maintenance. Push-in connection control cabinet manufacturing. The program
• Power supplies and device circuit breakers technology enables you to wire applications features an intuitive user interface that
• Terminal blocks and distribution blocks quickly – without using tools. The broad, enables the individual planning, automatic
• Relay modules and motor starters technologically leading product portfolio will checking, and direct ordering of terminal
• Signal conditioners always provide you with the right product for strips.
• Safety technology standard or special applications.
• Surge protection
• Heavy-duty connectors
Reduced logistics costs Optimized processes in control The new standard for the control
Reduced variety of parts, thanks to cabinet manufacturing cabinet
standardized marking, bridging, and testing COMPLETE line supports you, from Discover the extensive COMPLETE line
accessories. The COMPLETE line system engineering through to manufacturing, in product portfolio and find out more about
coordinates products, design, and accessories designing your control cabinet production COMPLETE line and your comprehensive
so that you benefit from maximum reusability as efficient as possible. This is how your solutions for the control cabinet.
and thus reduce your logistics costs. customized concept for optimizing your
processes in control cabinet manufacturing is Visit our website:
created. Our terminal strip production helps phoenixcontact.com/completeline
you to flexibly manage order peaks or to
supply your control cabinet production with
fully assembled DIN rails just in time.
PHOENIX CONTACT 87
Iceland Finland
Norway
Sweden Estonia
Latvia
Denmark Lithuania
Ireland Belarus
Netherlands Poland
United Kingdom
Blomberg, Germany Russia
Canada Belgium
Luxembourg Czech Republic
France Austria Slovakia Ukraine Kazakhstan Mongolia
Switzerland Hungary Moldova
Slovenia
Croatia Romania South Korea
USA Bosnia and
Spain Italy Serbia
Herzegovina Kosovo Japan
Montenegro Bulgaria Georgia Uzbekistan
Portugal Armenia China
Macedonia Turkey Azerbaijan
Greece
Tunisia
Lebanon Iraq
Morocco Cyprus Pakistan Taiwan, China
Kuwait Bangladesh
Mexico Israel
Algeria India Myanmar
Dominican Republic Jordan Bahrain
Guatemala Egypt Qatar Sri Lanka
Honduras Saudi Arabia
Nicaragua Thailand Philippines
Trinidad and Tobago UAE
Costa Rica
Panama Venezuela Oman Malaysia Vietnam
Ghana Nigeria
Colombia Cameroon Uganda Singapore
Kenya
Ecuador
Indonesia
Brazil
Peru Tanzania
Zambia
Bolivia Mozambique Mauritius
Namibia Zimbabwe
Botswana
Paraguay
South Africa
Chile
Uruguay
Australia
Argentina
New Zealand
phoenixcontact.com
PS 02-20.000.L3