Nothing Special   »   [go: up one dir, main page]

Power Supplies and UPS

Download as pdf or txt
Download as pdf or txt
You are on page 1of 88

Power supplies and UPS

2020/2021
Power for superior system availability
Our POWER products supply your applications with leading technology and high
quality. Power supplies, DC/DC converters, redundancy modules, and uninterruptible
power supplies are tailored in terms of their functionality and design to the demands of
various different industries.
With our QUINT, TRIO, UNO, and STEP product families, you are equipped to handle
competitors on an international scale.

The comprehensive solution for your control cabinet


The QUINT POWER product family is a
part of COMPLETE line. COMPLETE line
is a system comprised of coordinated
hardware and software products,
consulting services, and system solutions
that help you optimize your processes in
control cabinet manufacturing. Engineering,
purchasing, installation, and operation
become significantly easier for you. More
information on pages 86 to 87.

2 PHOENIX CONTACT
Contents
Power supplies for every application 4
QUINT POWER 8
TRIO POWER 16
Device circuit breakers 18
TRIO CROSS POWER 20
UNO POWER 22
STEP POWER 24

DC/DC converters 28
QUINT DC/DC converters 30
MINI DC/DC converters 34
TRIO DC/DC converters 35
UNO DC/DC converters 36

Inverters 38

Redundancy modules 42
Active redundancy modules 46
Passive redundancy modules 47

Uninterruptible power supplies 48


QUINT DC UPS 60
QUINT AC UPS 64
UPS with integrated energy storage 68
UPS with integrated power supply 72

Accessories 74

Approvals 78

COMPLETE line 86

Find out more


with the web code
For detailed information, use the web codes provided in this
brochure. Simply enter the # and the four-digit number in the
search field on our website.

Web code: #1234 (example)

Or use the direct link:


phoenixcontact.net/webcode/#1234

PHOENIX CONTACT 3
Power supplies for every application
Our power supplies are used in a wide variety of sectors and industries. With their
various functionalities, performance classes, and designs, they are the right partner for
your application.
• QUINT POWER: Automotive industry, systems manufacturing, process industry,
ship building
• TRIO POWER: Machine building
• UNO POWER: Electromobility
• STEP POWER: Urban infrastructure, building automation

4 PHOENIX CONTACT
PHOENIX CONTACT 5
Power supplies –
a comparison of your advantages
The product families differ with regard to their design, power, and functionality. Select
your solution here based on the requirements:
• QUINT POWER – powerful, and with maximum functionality
• TRIO POWER – robust with standard functionality
• UNO POWER – compact with basic functionality
• STEP POWER – for building automation

Shared features and differences


The power supplies of all the product families increase system features high operational safety. They can all be connected in parallel
availability and can be used worldwide, thanks to their international and can also be installed easily in outdoor control cabinets.
approval package and their wide range input. Each power supply

QUINT POWER
STEP UNO TRIO
POWER POWER POWER
<100 W >100 W

Worldwide application with a wide-range input and international approval package • • • • •

Maximum operating time with a high MTBF >500,000 h at +40°C • • • • •


Can be switched in parallel for increased performance and redundancy • • • • •
Outdoor installation permissible with a wide temperature range of -25°C ... +70°C • • • • •
Can be used in household applications in accordance with EN 60335 •
Active function monitoring via switching output for remote diagnostics • • •
Three-phase devices continue to operate without errors, even if one phase fails permanently • •

Reliable start-up of high loads with the dynamic boost power reserve • • •

Easy system extension with the static boost power reserve •* •


Magnetic tripping of miniature circuit breakers with SFB Technology •

Preventive function monitoring reports critical operating states before errors occur • •

Can be configured individually •

* Applies to the following devices: 2904597, 2904598, 2909575, 2909576, 2904605, 2904595

6 PHOENIX CONTACT
TRIO POWER QUINT POWER

UNO POWER

STEP POWER

PHOENIX CONTACT 7
QUINT POWER power supplies
The QUINT POWER power supplies from 1 A to 40 A form the core of our
QUINT portfolio.
With our small, compact QUINT POWER power supplies, we provide you with the
combination of preventive function monitoring and exceptional power reserves in a
compact size.
The powerful QUINT POWER power supplies with SFB Technology, preventive
function monitoring, and configurable settings ensure the availability of your system.

8 PHOENIX CONTACT
PHOENIX CONTACT 9
QUINT POWER power supplies <100 W

Powerful and space-saving


For the first time, QUINT POWER provides can choose between Push-in and screw
Web code: #1513
superior system availability in the smallest size connection technology for these power
in the power range of up to 100 W. Preventive supplies for the low-power range.
function monitoring and exceptional power
reserves are now also available for applications
in the low-power range. Furthermore, you

Your advantages
Startup of high loads, thanks to dynamic boost
Preventive function monitoring reports critical
operating states before errors occur
High efficiency and long service life with low power
dissipation and low heating
Space savings in the control cabinet, thanks to a
narrow, slim-line design

10 PHOENIX CONTACT
QUINT POWER power supplies >100 W

Maximum functionality with SFB Technology


Our powerful QUINT POWER power combination of SFB Technology, preventive
Web code: #1513
supplies with SFB Technology are ideally function monitoring, and long service life
suited for ensuring the availability of your increases the availability of your application.
system. The power reserve enables the The range of features is rounded out with
trouble-free start-up of high loads as well the customized configuration of signaling
as the easy extension of your system. The thresholds and characteristic curves.

SFB Technology Your advantages


(Selective Fuse Breaking) SFB Technology selectively triggers standard circuit
• Six times the nominal current for 15 ms triggers breakers; loads connected in parallel continue working
standard miniature circuit breakers quickly and reliably without interruption
• In the event of short-circuits, faulty current paths are Preventive function monitoring reports critical
disconnected selectively operating states before errors occur
• Faults are isolated to ensure that key system parts Power reserve for easy system extension with a static
remain in operation without interruptions boost with a sustained power of up to 125% and the
ability to start heavy loads with a dynamic boost of up
For superior system availability, standard circuit to 200% for five seconds
breakers must be triggered magnetically to disconnect High level of immunity with integrated gas discharge
faulty current paths selectively. To ensure this, the SFB tube, more than 20 ms mains buffering
Technology supplies several times the nominal current
Available preconfigured: from a batch quantity of just
for a short period, thus providing the necessary power
one
reserve.

Designed by PHOENIX CONTACT

PHOENIX CONTACT 11
QUINT POWER <100 W

QUINT POWER, with Push-in connection, 1~

Input 85 V AC ... 264 V AC 85 V AC ... 264 V AC 85 V AC ... 264 V AC

W x H x D in mm 22.5 x 106 x 90 32 x 106 x 90 45 x 106 x 90

24 V / 1.3 A 24 V / 2.5 A 24 V / 3.8 A


Type QUINT4-PS/1AC/24DC/1.3/PT QUINT4-PS/1AC/24DC/2.5/PT QUINT4-PS/1AC/24DC/3.8/PT
Order No. 2909575 2909576 2909577
12 V / 2.5 A 12 V / 7.5 A
Type QUINT4-PS/1AC/12DC/2.5/PT QUINT4-PS/1AC/12DC/7.5/PT
Order No. 2904605 2904607
5 V / 5 A
Type QUINT4-PS/1AC/5DC/5/PT
Order No. 2904595

QUINT POWER, with screw connection, 1~

Input 85 V AC ... 264 V AC 85 V AC ... 264 V AC 85 V AC ... 264 V AC

W x H x D in mm 22.5 x 99 x 90 32 x 99 x 90 45 x 99 x 90

24 V / 1.3 A 24 V / 2.5 A 24 V / 3.8 A


Type QUINT4-PS/1AC/24DC/1.3/SC QUINT4-PS/1AC/24DC/2.5/SC QUINT4-PS/1AC/24DC/3.8/SC
Order No. 2904597 2904598 2904599

12 PHOENIX CONTACT
QUINT POWER >100 W

QUINT POWER, 1~

85 V AC ... 264 V AC, 85 V AC ... 264 V AC, 85 V AC ... 264 V AC, 85 V AC ... 264 V AC,
Input
90 V DC ... 350 V DC 90 V DC ... 350 V DC 90 V DC ... 350 V DC 90 V DC ... 350 V DC
W x H x D in mm 36 x 130 x 125 50 x 130 x 125 70 x 130 x 125 120 x 130 x 140

24 V / 5 A 24 V / 10 A 24 V / 20 A 24 V / 40 A


Type QUINT4-PS/1AC/24DC/5 QUINT4-PS/1AC/24DC/10 QUINT4-PS/1AC/24DC/20 QUINT4-PS/1AC/24DC/40
Order No. 2904600 2904601 2904602 2904603
12 V / 15 A
Type QUINT4-PS/1AC/12DC/15
Order No. 2904608
48 V / 5 A 48 V / 10 A
Type QUINT4-PS/1AC/48DC/5 QUINT4-PS/1AC/48DC/10
Order No. 2904610 2904611

QUINT POWER, 3~

3 x 320 V AC ... 550 V AC, 3 x 320 V AC ... 550 V AC, 3 x 320 V AC ... 550 V AC, 3 x 320 V AC ... 550 V AC,
Input 2 x 360 V AC ... 550 V AC, 2 x 360 V AC ... 550 V AC, 2 x 360 V AC ... 550 V AC, 2 x 360 V AC ... 550 V AC,
+/- 300 V DC +/- 260 ... 300 V DC +/- 260 ... 300 V DC +/- 260 ... 300 V DC
W x H x D in mm 36 x 130 x 125 50 x 130 x 125 70 x 130 x 125 120 x 130 x 125

24 V / 5 A 24 V / 10 A 24 V / 20 A 24 V / 40 A


Type QUINT4-PS/3AC/24DC/5 QUINT4-PS/3AC/24DC/10 QUINT4-PS/3AC/24DC/20 QUINT4-PS/3AC/24DC/40
Order No. 2904620 2904621 2904622 2904623

QUINT POWER*, 1~ and 3~

85 V AC ... 264 V AC, 85 V AC ... 264 V AC, 85 V AC ... 264 V AC, 3 x 320 V AC ... 575 V AC,
Input
90 V DC ... 350 V DC 90 V DC ... 350 V DC 90 V DC ... 300 V DC 450 V DC ... 800 V DC
W x H x D in mm 32 x 130 x 125 90 x 130 x 125 180 x 130 x 125 96 x 130 x 176

1 AC / 24 V / 3.5 A 1 AC / 12 V / 20 A 1 AC / 48 V / 20 A 3 AC / 48 V / 20 A
Type QUINT-PS/1AC/24DC/3.5 QUINT-PS/1AC/12DC/20 QUINT-PS/1AC/48DC/20 QUINT-PS/3AC/48DC/20
Order No. 2866747 2866721 2866695 2320827
* Devices with differing functions; additional information is available on the product pages at www.phoenixcontact.com
PHOENIX CONTACT 13
QUINT POWER power supplies >100 W

QUINT POWER with SFB Technology for extreme ambient conditions


The PCB coating (CO stands for coated)
protects against dust, corrosive gases, and
100% humidity. Failures due to creepage
currents and electrochemical migration
caused by corrosion are also prevented. The
components are protected within a wide
temperature range of -40°C to +70°C.

DC/DC converters with the same properties


are listed on page 31.

Redundancy modules for extreme conditions


are listed on page 46.

QUINT POWER Plus version – the power supply for demanding applications
Then QUINT POWER Plus version is the accordance with IEC 61508 and IEC 61511),
solution for demanding applications under thus ensuring maximum operational safety.
extreme ambient conditions.
With a protective coating and ATEX and
With integrated decoupling MOSFET for IECEx approval in accordance with the
1+1 and n+1 redundancy, the Plus version standards IEC 60079-0, IEC 60079-7,
provides symmetrical load distribution and IEC 60079-11, and IEC 60079-15, it can also
increases system availability. Furthermore, be used within potentially explosive areas
errors can be detected early on via of zone 2.
configurable output current signaling
thresholds. At the same time, you save time The Plus version is rounded off with a wide
and space thanks to the reduced wiring temperature range of -40°C to +75°C for
work. use under extreme ambient conditions.

The Plus version with double OVP


(OverVoltage Protection) also protects
your system against voltage increases. In the
event of an error, the output is switched off
to protect the loads against overvoltages.

The functional safety standards and


directives ensure reliable protection for
people, the environment, and machinery.

The QUINT POWER Plus version satisfies


these requirements (SIL 3, HFT = 1 in

14 PHOENIX CONTACT
QUINT POWER 1~

85 V AC ... 264 V AC, 85 V AC ... 264 V AC, 85 V AC ... 264 V AC,


Input
90 V DC ... 350 V DC 90 V DC ... 350 V DC 90 V DC... 350 V DC
W x H x D in mm 70 x 130 x 125 50 x 130 x 125 70 x 130 x 125

24 V / 20 A / + 24 V / 10 A / CO New 48 V / 10 A / CO New


Type QUINT4-PS/1AC/24DC/20/+ QUINT4-PS/1AC/24DC/10/CO QUINT4-PS/1AC/48DC/10/CO
Order No. 2904617 2904625 2904626

QUINT POWER*, 1~ and 3~, with protective coating

1-phase, 85 V AC ... 264 V AC, 1-phase, 85 V AC ... 264 V AC, 1-phase, 85 V AC ... 264 V AC, 3-phase, 3 x 320 ... 575 V AC,
Input
90 V DC ... 430 V DC 90 V DC ... 430 V DC 90 V DC ... 430 V DC 450 V DC ... 800 V DC
W x H x D in mm 40 x 130 x 125 60 x 130 x 125 90 x 130 x 125 69 x 130 x 125

1 AC / 24 V / 5 A / CO 1 AC / 24 V / 10 A / CO 1 AC / 24 V / 20 A / CO 3 AC / 24 V / 20 A / CO
Type QUINT-PS/1AC/24DC/5/CO QUINT-PS/1AC/24DC/10/CO QUINT-PS/1AC/24DC/20/CO QUINT-PS/3AC/24DC/20/CO
Order No. 2320908 2320911 2320898 2320924
* Devices with differing functions; additional information is available on the product pages at www.phoenixcontact.com

Maximum protection for your system


For extreme operating conditions, use Further information and conditions can be
the ideally matched combination of the found on the Internet under Order Number
PLUGTRAB SEC surge protection device 2907928 at www.phoenixcontact.com
and the powerful fourth generation
QUINT POWER power supply.

5-year warranty
If your fourth-generation QUINT POWER
becomes damaged in the first five years
following purchase despite the using
this combination, you will receive a free
replacement.

PHOENIX CONTACT 15
TRIO POWER power supplies

Robust with standard functionality


The TRIO POWER power supplies are The power supplies, which feature a robust
characterized by standard functionality, high electrical and mechanical design, ensure the
quality, and reliability. They are particularly reliable supply to all loads, even under harsh
well-suited for use in machine building. All ambient conditions.
functions and the space-saving design are
Web code: #0497
tailored to the stringent demands in this field.

Your advantages
Very cost-effective with time-saving, tool-free Push-in
connection and a slim design
Reliable startup of high loads thanks to the dynamic
power reserve, with 150% of the nominal current for
a maximum of five seconds
Electrically robust with a high electric strength
Mechanically robust with high vibration and shock
resistance

16 PHOENIX CONTACT
TRIO POWER with Push-in connection, 1~

Input 85 ... 264 V AC, 99 ... 275 V DC 85 ... 264 V AC, 99 ... 275 V DC 85 ... 264 V AC, 99 ... 275 V DC 85 ... 264 V AC, 99 ... 275 V DC
W x H x D in mm 30 x 130 x 115 35 x 130 x 115 42 x 130 x 160 68 x 130 x 160

24 V / 3 A / C2LPS* 24 V / 5 A 24 V / 10 A 24 V / 20 A


TRIO-PS-2G/ TRIO-PS-2G/ TRIO-PS-2G/ TRIO-PS-2G/
Type
1AC/24DC/3/C2LPS 1AC/24DC/5 1AC/24DC/10 1AC/24DC/20
Order No. 2903147 2903148 2903149 2903151
24 V / 5 A / B+D 24 V / 10 A / B+D
TRIO-PS-2G/ TRIO-PS-2G/
Type
1AC/24DC/5/B+D 1AC/24DC/10/B+D
Order No. 2903144 2903145
12 V/5 A/C2LPS* 12 V / 10 A
TRIO-PS-2G/ TRIO-PS-2G/
Type
1AC/12DC/5/C2LPS 1AC/12DC/10
Order No. 2903157 2903158
48 V / 5 A 48 V / 10 A
Type TRIO-PS-2G/1AC/48DC/5 TRIO-PS-2G/1AC/48DC/10
Order No. 2903159 2903160

TRIO POWER with Push-in connection, 3~

3 x 320 V AC ... 575 V AC, 3 x 320 V AC ... 575 V AC, 3 x 320 V AC... 575 V AC, 3 x 320 V AC ... 575 V AC
Input
2 x 360 V AC ... 575 V AC 2 x 360 V AC ... 575 V AC 2 x 360 V AC ... 575 V AC
W x H x D in mm 35 x 130 x 115 42 x 130 x 160 65 x 130 x 160 110 x 130 x 160

24 V / 5 A 24 V / 10 A 24 V / 20 A 24 V / 40 A


Type TRIO-PS-2G/3AC/24DC/5 TRIO-PS-2G/3AC/24DC/10 TRIO-PS-2G/3AC/24DC/20 TRIO-PS-2G/3AC/24DC/40
Order No. 2903153 2903154 2903155 2903156

TRIO POWER with


Push-in connection, Robust, with IP67 degree of protection
3~
The new TRIO POWER power supplies with IP67 degree of protection are
particularly well suited for installation in the field. Thanks to its weather-
resistant design, you can also use the device in harsh ambient conditions.

• TRIO-PS-IP67/1AC/24DC/20,
Input: 100 V AC ... 240 V AC
Order No.: 1039830
Input 3 x 320 V AC ... 575 V AC
W x H x D in mm 110 x 130 x 160 • TRIO-PS-IP67/3AC/24DC/20,
Input: 3 x 400 V AC ... 500 V AC
72 V / 14 A Order No.: 1039829
Type TRIO-PS-2G/3AC/72DC/14
Order No. 1076188

* NEC Class 2 output, certified in accordance with UL 1310 / Web code: #2177


Limited Power Source (LPS) in accordance with UL 60950-1

PHOENIX CONTACT 17
Power supplies

Device circuit breakers – suitable for all applications


Increase the availability of your system by The complete portfolio of electronic circuit
safeguarding the output voltage of your power breakers also provides intelligent protection.
supply. Protect your system effectively against Take advantage of the easy handling and
overload and short-circuit currents at the simple product selection.
same time.

Your advantages
Suitable device protection for any requirement, thanks
to the comprehensive portfolio
System statuses under control with intelligent analysis
and fault signaling
Easy startup with tool-free connection technology
and intuitive operation

18 PHOENIX CONTACT
Multi-channel electronic circuit breakers

Web code: #1646

4-channel 8-channel 4-channel 4-channel


Nominal current 0.5 A ... 10 A 0.5 A ... 10 A 1 A ... 4 A* 1 A... 10 A
Type CBM E4 24DC/0.5-10A NO-R CBM E8 24DC/0.5-10A NO-R CBMC E4 24DC/1-4A NO CBMC E4 24DC/1-10A NO
Order No. 2905743 2905744 2906031 2906032

Single-channel electronic circuit breakers

Web code: #1645

Single-channel Single-channel Single-channel Single-channel


Nominal current 1 A ... 3 A* 1 A ... 8 A 2 A* 6 A
Type PTCB E1 24DC/1-3A NO PTCB E1 24DC/1-8A NO PTCB E1 24DC/2A NO PTCB E1 24DC/6A NO
Order No. 2909909 2908262 2909903 2909908
* NEC Class 2 outputs, in accordance with UL 1310

Single-channel electronic circuit breakers

Web code: #1645

Base element /
Single-channel Single-channel Single-channel
Push-in connection
Nominal current 1 A 6 A 10 A
Type CB E1 24DC/1A NO P CB E1 24DC/6A NO P CB E1 24DC/10A NO P CB 1/6-2/4 PT-BE
Order No. 2800901 2800905 2800907 2800929

Thermomagnetic device circuit breakers

Web code: #1647

Base element /
F1 SFB M1
screw connection
Nominal current 0.5 A 6 A 16 A
Type CB TM1 0.5A F1 P CB TM1 6A SFB P CB TM1 16A M1 P CB 1/10-1/10 UT-BE
Order No. 2800857 2800841 2800856 2801305

PHOENIX CONTACT 19
TRIO CROSS POWER power supplies

The DIN rail with built-in power distribution


The new TRIO POWER power supplies for The Push-in connection enables quick and
the CrossPowerSystem power distribution easy connection of 24 V DC loads. Tool-free
board are perfectly suited for use in machine mounting and automatic contacting via
building. All functions and the space-saving convenient snap-on connections enable easy
design are tailored to the stringent demands startup.
in this field.
Web code: #2178

Connection side of the


power distribution board

Your advantages
Push-in connection enables the quick and easy
snap-on connection of 24 V DC loads
Rapid startup: tool-free mounting and automatic
contacting in just one step (CrossPowerSystem)
Reliable startup of high loads with dynamic boost
Electrically robust with a high electric strength
High degree of flexibility with the wide temperature
range of -25°C … +70°C and device startup at -40°C

20 PHOENIX CONTACT
TRIO CROSS POWER 3~

Input 3 x 400 V AC ... 500 V AC 3 x 400 V AC ... 500 V AC


W x H x D in mm 36 x 160 x 159 70.5 x 209.7 x 170

24 V / 5 A 24 V / 20 A / 8C / IOL New

Type EM-CPS-PS/3AC/24DC/5 EM-CPS-PS/3AC/24DC/20/8C/IOL

Order No. 1064922 1067898

TRIO CROSS POWER with 8-channel electronic circuit breakers


The 20 A power supply with integrated The channel-specific nominal voltages
8-channel electronic circuit breaker is a can be configured without tools via LED
new addition. The power supply with eight buttons in 1 A increments (1 A to 10 A).
independent channels also provides reliable Furthermore, the power supply can be
protection for disconnection in the event accessed from anywhere in the world via
of errors (overload or short circuit) and the IO-Link infrastructure.
comprehensive diagnostics options.

CrossPowerSystem
The CrossPowerSystem is a new and
open platform for modular and functional
control cabinets. Three-phase devices can
be mounted onto the power distributor
easily via Plug and Play. Time is money, and
this is particularly true in the construction
of machines and systems. Thanks to the
combination of power distribution and
switching devices, mounting on the power
distribution board is now even faster.
Furthermore, the integrated reverse pole
protection prevents errors and ensures even
simpler startup.

PHOENIX CONTACT 21
UNO POWER power supplies

Compact with basic functionality


Thanks to their high power density, UNO The range of 18 devices covers output
Web code: #1512
POWER power supplies are the perfect voltages of 5 to 48 V DC and includes six
solution, particularly in compact control designs. The UNO UPS uninterruptible power
cabinets. The efficient technology with low supply and the UNO DIODE redundancy
no-load losses and high efficiencies in a small module suitable for the power supplies are
housing covers loads from 25 W to 480 W. also available.

Your advantages
High energy efficiency with an efficiency of up to
94% and with extremely low idling losses of less than
0.3 W
Particularly compact, thanks to high power density
Outdoor installation possible with a wide temperature
range of -25°C to +70°C

22 PHOENIX CONTACT
UNO POWER, 1~

Input 85 V AC ... 264 V AC 85 V AC ... 264 V AC 85 V AC ... 264 V AC
W x H x D in mm 22.5 x 90 x 84 35 x 90 x 84 55 x 90 x 84

24 V/30 W 24 V/60 W 24 V/100 W


Type UNO-PS/1AC/24DC/30W UNO-PS/1AC/24DC/60W UNO-PS/1AC/24DC/100W
Order No. 2902991 2902992 2902993
24 V / 100 W / H**
Type UNO-PS/1AC/24DC/100W/H
Order No. 1088851
24 V / 90 W / C2LPS*
Type UNO-PS/1AC/24DC/90W/C2LPS
Order No. 2902994
48 V/60 W 48 V/100 W
Type UNO-PS/1AC/48DC/60W UNO-PS/1AC/48DC/100W
Order No. 2902995 2902996
15 V/30 W 15 V/55 W 15 V/100 W
Type UNO-PS/1AC/15DC/30W UNO-PS/1AC/15DC/55W UNO-PS/1AC/15DC/100W
Order No. 2903000 2903001 2903002
12 V/30 W 12 V/55 W 12 V/100 W
Type UNO-PS/1AC/12DC/30W UNO-PS/1AC/12DC/55W UNO-PS/1AC/12DC/100W
Order No. 2902998 2902999 2902997
12 V / 55 W / H**
Type UNO-PS/1AC/12DC/55W/H
Order No. 1088850
5 V/25 W 5 V/40 W
Type UNO-PS/1AC/5DC/25W UNO-PS/1AC/5DC/40W
Order No. 2904374 2904375

UNO POWER, 1~ UNO POWER, 2~

Input 85 V AC ... 264 V AC 85 V AC ... 264 V AC 85 V AC ... 264 V AC 264 V AC ... 575 V AC
W x H x D in mm 37 x 130 x 125 45 x 130 x 125 59 x 130 x 125 55 x 90 x 84

24 V/150 W 24 V/240 W 24 V/480 W 24 V / 90 W / C2LPS*


UNO-PS/2AC/24DC/90W/
Type UNO-PS/1AC/24DC/150W UNO-PS/1AC/24DC/240W UNO2-PS/1AC/24DC/480W
C2LPS
Order No. 2904376 2904372 2910105 2904371

* NEC Class 2 output, certified in accordance with UL 1310 / Limited Power Source (LPS) in accordance with UL 60950-1
** Can be used in household applications in accordance with EN 60335

PHOENIX CONTACT 23
STEP POWER power supplies

For building automation


The STEP POWER power supplies have been the terminal block provides twice the number
Web code: #2433
specifically developed for building automation of terminal points. The power of the new
applications. The new generation of devices device generation has been increased by up
are among the first power supplies in the to 100%, while the overall width has been
world with Efficiency Level VI. With EN 60335 reduced by one horizontal pitch. With the
certification, the power supplies can be used new 5 A device, a power supply in the higher
in all domestic applications. The Push-in power range is now available.
connection of the 45° terminal blocks enables
quick and easy commissioning. Furthermore,

Your advantages
Energy savings with efficiency in no-load and part-load
operation (Efficiency Level VI)
Space savings in the control cabinet with the narrow
design, combined with increased power (up to 100%)
Approval for household purposes (EN 60335) enables
use in domestic applications for the first time, built
into in horizontal pitches (DIN 43880)
Quick and easy startup with tool-free Push-in
connection technology at a 45° angle with double
terminal points

24 PHOENIX CONTACT
Efficiency standards for external power supplies
The new generation of the STEP POWER The new power supplies of the In no-load operation, the no-load losses
power supplies satisfy the currently highest STEP POWER family currently have the of all STEP POWER power supplies are
efficiency standard requirements. With the highest efficiencies on the market. below 0.1 W or 0.21 W depending on
combination of very high efficiencies and • Efficiency during normal operation: performance class, and are therefore setting
low no-load losses, the power supplies are >94.5% new standards.
the first DIN rail devices in the world rated • Efficiency during part-load operation:
with Efficiency Level VI. >90%

Back in the 1990s, the efficiency of external With the new 5 A power supply, a device is
power supply units was just 50%. This now available that provides twice the power
prompted the United States Environmental compared to previous power supplies with
Protection Agency to develop a voluntary an identical overall width (four horizontal
program to promote energy efficiency and pitches).
reduce pollution in 1992. However, it was
only in 2004 that the first regulations were
developed with minimum requirements [%] STEP-PS/1AC/24DC/5/PT
on efficiency and load-free electricity 96
consumption. A great deal has happened
since then, and efforts are continually being 94
made to significantly reduce the energy
consumption of external power supply units.
92
The result of these efforts, Efficiency Level
VI, currently places the highest demands on
energy efficiency. 90
Efficiency

In addition to Efficiency Level VI, the 88


STEP POWER power supplies also satisfy
the EU commission regulation on ecodesign 86
requirements (EU) 2019/1782, which comes
into effect on April 1, 2020. The aim of this 84
is also to improve the energy efficiency and
environmental compatibility. 82

80 [%]

0 20 40 60 80 100 120

Output power of the device

Safe use of electrical devices


The new STEP POWER power supplies devices and their supply must therefore be
satisfy DIN EN 60335 for the first time. taken particularly seriously.
This standard describes the requirements
to be satisfied for the safety of electrical The new STEP POWER power supplies
devices for household use and similar or for satisfy both the requirements in the field of
commercial purposes. building automation and in the commercial
sector.
Devices with a rated voltage of between
250 V and 480 V are to be found in bakery
ovens in supermarkets, in large washing
machines in hotels, and also in agriculture
and in conventional residential buildings.
Normally, these devices and machines
are operated by users without specialist
training. The electrical safety of these

PHOENIX CONTACT 25
STEP POWER with household approval (EN 60335)

STEP POWER, 1~

100 V AC ... 240 V AC 100 V AC ... 240 V AC 100 V AC ... 240 V AC 100 V AC ... 240 V AC
Input
110 V DC ... 250 V DC 110 V DC ... 250 V DC 110 V DC ... 250 V DC 110 V DC ... 250 V DC
W x H x D in mm 18 x 90 x 55 36 x 90 x 55 54 x 90 x 55 72 x 90 x 55

24 V / 0.63 A 24 V / 1.3 A 24 V / 2.5 A 24 V / 4 A


Type STEP3-PS/1AC/24DC/0.63/PT STEP3-PS/1AC/24DC/1.3/PT STEP3-PS/1AC/24DC/2.5/PT STEP3-PS/1AC/24DC/4/PT
Order No. 1088495 1088494 1088491 1140066
24 V / 5 A
Type STEP3-PS/1AC/24DC/5/PT
Order No. 1088478

26 PHOENIX CONTACT
STEP POWER

STEP POWER, 1~

Shallow
design

85 V AC ... 264 V AC 85 V AC ... 264 V AC 85 V AC ... 264 V AC 85 V AC ... 264 V AC
Input
95 V DC ... 250 V DC 95 V DC ... 250 V DC 95 V DC ... 250 V DC 95 V DC ... 250 V DC
W x H x D in mm 18 x 90 x 61 36 x 90 x 43 36 x 90 x 61 54 x 90 x 61

24 V / 0.5 A 24 V / 0.75 A FL 24 V / 0.75 A 24 V / 1.75 A


Type STEP-PS/1AC/24DC/0.5 STEP-PS/1AC/24DC/0.75/FL STEP-PS/1AC/24DC/0.75 STEP-PS/1AC/24DC/1.75
Order No. 2868596 2868622 2868635 2868648
12 V / 1 A 12 V / 1.5 A FL 12 V / 1.5 A 12 V / 3 A
Type STEP-PS/1AC/12DC/1 STEP-PS/1AC/12DC/1.5/FL STEP-PS/1AC/12DC/1.5 STEP-PS/1AC/12DC/3
Order No. 2868538 2868554 2868567 2868570
5 V/2 A
Type STEP-PS/1AC/5DC/2
Order No. 2320513

STEP POWER, 1~ STEP for 48 V AC STEP for 277 V AC

85 V AC ... 264 V AC 85 V AC ... 264 V AC 43 V AC ... 52 V AC 85 V AC ... 305 V AC
Input
95 V DC ... 250 V DC 95 V DC ... 250 V DC 60 V DC ... 80 V DC 95 V DC ... 250 V DC
W x H x D in mm 72 x 90 x 61 90 x 90 x 61 18 x 90 x 61 90 x 90 x 61

24 V / 2.5 A 24 V / 4.2 A 48 V AC / 24 V DC / 0.5 A 277 V AC / 24 V DC / 3.5 A


Type STEP-PS/1AC/24DC/2.5 STEP-PS/1AC/24DC/4.2 STEP-PS/48AC/24DC/0.5 STEP-PS/277AC/24DC/3.5
Order No. 2868651 2868664 2868716 2904945
15 V / 4 A 24 V / 100 W / C2LPS*
Type STEP-PS/1AC/15DC/4 STEP-PS/1AC/24DC/3.8/C2LPS
Order No. 2868619 2868677
12 V / 5 A 48 V / 2 A
Type STEP-PS/1AC/12DC/5 STEP-PS/1AC/48DC/2
Order No. 2868583 2868680
5 V / 6.5 A
Type STEP-PS/1AC/5DC/6.5
Order No. 2868541
* NEC Class 2 output, certified in accordance with UL 1310 / Limited Power Source (LPS) in accordance with UL 60950-1

PHOENIX CONTACT 27
DC/DC converters
For a regulated direct voltage
Avoid disturbances in your application by using DC/DC converters. The load is
always supplied with a regulated direct voltage, even when using long cable lengths.
Phoenix Contact provides:
• DC/DC converters with SFB Technology and for extreme demands
• DC/DC converters for control technology
• DC/DC converters for photovoltaic applications

28 PHOENIX CONTACT
PHOENIX CONTACT 29
QUINT DC/DC converters

Adapt voltages
DC/DC converters provide a regulated direct QUINT DC/DC converters with the connection technology for the new
voltage. They regenerate voltages so that the SFB Technology, preventive function generation.
load is always supplied with a regulated DC monitoring, long service life, and IECEx
Web code: #0152
voltage, even in the case of long cable lengths. approval increase the availability of your
Furthermore, the electrical isolation ensures application. Furthermore, the dynamic
the establishment of independent supply boost feature allows high loads to be
systems. started. In addition, you are free to choose

Your advantages
SFB Technology selectively triggers standard circuit
breakers; loads connected in parallel continue working
without interruption
Preventive function monitoring reports critical
operating states before errors occur
Power reserve for easy system extension with a static
boost with a sustained power of up to 125% and the
ability to start heavy loads with a dynamic boost of up
to 200% for five seconds
Free selection between Push-in and screw connection

30 PHOENIX CONTACT
Plus version for extreme ambient conditions
The Plus version of the DC/DC converter The new Plus version is rounded out with a
with integrated decoupling MOSFET for 1+1 wide temperature range of -40°C to +70°C
and n+1 redundancy provides symmetrical for use under extreme ambient conditions.
load distribution and increases system
availability. Furthermore, it satisfies the The protective PCB coating (CO stands
requirements for functional safety (SIL 2). for coated) protects against dust, corrosive
gases, and also against 100% humidity.
With a protective coating, and ATEX Failures due to creepage currents and
and IECEx approval in accordance with electrochemical migration caused by
the standards IEC 60079-0, IEC 60079-7, corrosion are also prevented.
IEC 60079-11, and IEC 60079-15, it can also
be used within potentially explosive areas
of zone 2.

Fourth generation QUINT POWER voltage levels


The fourth generation of the DC/DC Input
converters of the QUINT family is suitable 24 V DC* 48 V DC
for high powers with currents up to 20 A. (18 V DC … 32 V DC) (29  V DC … 57.5 V DC)

Thanks to the large input voltage range,


all common input and output voltages in
the performance classes up to 480 W are
covered.
24 V DC*
12 V DC 48 V DC
The IECEx approvals enable use in all (12 V DC ... 15 V DC)
(24 V DC ...
(48 V DC ... 56 V DC)
29.5 V DC)
industries, including the process industry. Output

* From 14 ... 32 V DC during operation

Third generation QUINT POWER voltage levels


The third generation of the DC/DC Input Input
converters of the QUINT family is suitable
for high powers with currents up to 20 A. 12 V DC 24 V DC* 60 V DC … 72 V DC 96 V DC … 110 V DC*
(9 V DC … 18 V DC) (18 V DC … 32 V DC) (42 V DC … 96 V DC) (67.2 V DC … 154 V DC)

The common input and output voltages


in the performance classes up to 480 W
are covered. The IECEx approvals for the
devices with protective coating enable
use in all industries, including the process
industry. 12 V DC 24 V DC* 24 V DC
(5 V DC … 18 V DC) (18 V DC … 29.5 V DC) (18 V DC … 29.5 V DC)

The QUINT DC/DC converters with Output Output


wide-range input are ideal for applications in
* From 14 ... 32 V DC during operation
the rail industry and power generation, for
example.

PHOENIX CONTACT 31
QUINT DC/DC converters

QUINT DC/DC converters with Push-in connection

Input 18 V DC ... 32 V DC 18 V DC ... 32 V DC 18 V DC ... 32 V DC
W x H x D in mm 36 x 130 x 125 50 x 130 x 125 70 x 130 x 125

24 V / 24 V / 5 A 24 V / 24 V / 10 A 24 V / 24 V / 20 A New


QUINT4-PS/ QUINT4-PS/ QUINT4-PS/
Type
24DC/24DC/5/PT 24DC/24DC/10/PT 24DC/24DC/20/PT
Order No. 2910119 2910120 2910121

QUINT DC/DC converters with Push-in connection

Input 18 V DC ... 32 V DC 29 V DC ... 57.5 V DC 18 V DC ... 32 V DC 29 V DC ... 57.5 V DC
W x H x D in mm 36 x 130 x 125 36 x 130 x 125 50 x 130 x 125 50 x 130 x 125

24 V / 12 V / 8 A 48 V / 24 V / 5 A 24 V / 48 V / 5 A New 48 V / 48 V / 5 A New
QUINT4-PS/ QUINT4-PS/ QUINT4-PS/ QUINT4-PS/
Type
24DC/12DC/8/PT 48DC/24DC/5/PT 24DC/48DC/5/PT 48DC/48DC/5/PT
Order No. 2910122 2910125 2910123 2910128

QUINT DC/DC converters with screw connection

Input 18 V DC ... 32 V DC 18 V DC ... 32 V DC 18 V DC ... 32 V DC 18 V DC ... 32 V DC
W x H x D in mm 36 x 130 x 125 50 x 130 x 125 70 x 130 x 125 70 x 130 x 125

24 V / 24 V / 5 A 24 V / 24 V / 10 A 24 V / 24 V / 20 A New 24 V/24 V/20 A/+ New


QUINT4-PS/ QUINT4-PS/ QUINT4-PS/ QUINT4-PS/
Type
24DC/24DC/5/SC 24DC/24DC/10/SC 24DC/24DC/20/SC 24DC/24DC/20/SC/+
Order No. 1046800 1046803 1046805 1046881

32 PHOENIX CONTACT
QUINT DC/DC converters*

Input 9 V DC ... 18 V DC 9 V DC ... 18 V DC


W x H x D in mm 32 x 130 x 125 32 x 130 x 125

12 V/24 V/5 A 12 V/12 V/8 A
QUINT-PS/ QUINT-PS/
Type
12DC/24DC/5 12DC/12DC/8
Order No. 2320131 2905007

QUINT DC/DC converters* …, with protective coating

Input 42 V DC ... 96 V DC 67.2 V DC ... 154 V DC 42 V DC ... 96 V DC 67.2 V DC ... 154 V DC
W x H x D in mm 48 x 130 x 125 48 x 130 x 125 48 x 130 x 125 48 x 130 x 125

60 V ... 72 V / 24 V / 10 A 96 V ... 110 V / 24 V / 10 A 60 V ... 72 V / 24 V / 10 A / CO 96 V ... 110 V / 24 V / 10 A / CO
QUINT-PS/ QUINT-PS/ QUINT-PS/ QUINT-PS/
Type
60-72 DC/24DC/10 96-110 DC/24DC/10 60-72 DC/24DC/10/CO 96-110 DC/24DC/10/CO
Order No. 2905009 2905010 2905011 2905012

QUINT DC/DC converters*, with protective coating

Input 18 V DC ... 32 V DC 18 V DC ... 32 V DC 18 V DC ... 32 V DC
W x H x D in mm 32 x 130 x 125 48 x 130 x 125 82 x 130 x 125

24 V/24 V/5 A/ CO 24 V/24 V/10 A/ CO 24 V/24 V/20 A/ CO


QUINT-PS/ QUINT-PS/ QUINT-PS/
Type
24DC/24DC/5/CO 24DC/24DC/10/CO 24DC/24DC/20/CO
Order No. 2320542 2320555 2320568
* Devices with differing functions; additional information is available on the product pages at www.phoenixcontact.com

PHOENIX CONTACT 33
MINI DC/DC converters

For low powers


MINI DC/DC converters are particularly The MINI DC/DC converters are suitable
Web code: #0152
suitable for measurement and control for low power ratings. They are available for
technology. Connection is quick and easy voltages from 10 V DC to 75 V DC. They
using COMBICON connectors. An LED and supply currents between 0.7 A and 2 A.
an active switching output monitor the output
voltage.

MINI POWER voltage levels

Input

12 V DC … 24 V DC 48 V DC … 60 V DC
(10 V DC … 32 V DC) (36 V DC … 75 V DC)

5 V DC … 15 V DC 24 V DC 48 V DC
(5 V DC … 15 V DC) (22.5 V DC … 28.5 V DC) (30 V DC … 56 V DC)

Output

MINI DC/DC converters Accessories*

Input 10 V DC ... 32 V DC 10 V DC ... 32 V DC 36 ... 75 V DC / 10 ... 32 V DC 1-phase, 10 V DC ... 42 V AC
W x H x D in mm 22.5 x 99 x 107 22.5 x 99 x 107 22.5 x 99 x 107 22.5 x 99 x 107

10 V AC ... 42 V AC /


12 V ... 24 V / 24 V / 1 A 12 V ... 24 V / 5 ... 15 V / 2 A 48 V ... 60 V / 24 V / 1 A
15 V DC ... 60 V DC / 3 A*
Type MINI-PS-12-24DC/24DC/1 MINI-PS-12-24DC/5-15DC/2 MINI-PS-48-60DC/24DC/1 MINI-PS-10-42AC/15-60DC/3
Order No. 2866284 2320018 2866271 2320199
12 V ... 24 V / 48 V / 0.7 A
Type MINI-PS-12-24DC/48DC/0.7
Order No. 2320021
* AC power terminal for connection upstream of MINI DC/DC converters; the AC voltage of a transformer is rectified and filtered.

34 PHOENIX CONTACT
TRIO DC/DC converters

For decentralized power supply


The DC/DC converter with 1500 V DC possible to start the central inverter with the
Web code: #2431
supplies your system directly from the TRIO DC/DC converter without a supply
field and provides a reliable power supply grid. In drive technology, the device also
even without a central grid. It is suitable generates 24 V DC directly in the machine to
for applications in photovoltaics and drive supply the system controller.
technology. In photovoltaic systems, it is even

Your advantages
Specifically developed for the
high DC voltages of photovoltaic
systems
Suitable for use in all photovoltaic
systems with high input voltage
due to conformity with standard
UL 62109; supports potential-free
grounding
In photovoltaic systems, the
central inverter can be started
without an additional AC
connection
High system availability due to the
robust design
Quick and easy installation with
Push-in connection

TRIO DC/DC converters

Input 600 V DC ... 1500 V DC


W x H x D in mm 88.5 x 130 x 160

1500 V / 8 A New

Type TRIO-PS-2G/1500DC/24DC/8
Order No. 1075240

PHOENIX CONTACT 35
UNO DC/DC converters

For direct supply


Supply your control cabinet directly from therefore save additional installation costs
Web code: #0152
the photovoltaic system with the DC/DC and increase system efficiency. In a further
converters of the UNO POWER range. The expansion stage, the signal line can be
Combiner Box is supplied directly from the replaced by a wireless connection.
PV panel, thanks to the direct connection
to string voltages of up to 1000 V DC. You

Your advantages
Wide input voltage range of 300 V DC … 1000 V DC
Direct field installation possible; an AC connection is
no longer necessary
Simplified approval of the overall system, thanks to
UL 1741 certification for the DC/DC converter
Low space requirement in the control box, thanks to
the compact design and a high degree of efficiency
Simplified startup, thanks to LED function monitoring

36 PHOENIX CONTACT
UNO DC/DC converters

Input 350 V DC ... 900 V DC


W x H x D in mm 55 x 90 x 84

350 DC ... 900 DC / 24 DC / 60 W


Type UNO-PS/350-900DC/24DC/60W
Order No. 2906300

Connection options for Combiner Boxes in photovoltaic systems

In the application shown, the Combiner Box is connected UNO POWER devices allow direct connection to string In a further expansion stage, the signal line can be replaced
to a supply line (red, e.g. 230 V AC) and a signal line (black). voltages of up to 1000 V DC. This means that the by a wireless connection.
Laying the lines involves significant installation costs. Combiner Box is supplied directly from the photovoltaic
panel, and additional installation costs are not incurred.

PHOENIX CONTACT 37
Inverters for converting direct current into
alternating current
The QUINT inverter reliably converts direct current into alternating current.
The inverter from Phoenix Contact provides:
• A pure sine curve
• Electricity with a constant high quality, without dangerous voltage fluctuations
• Trouble-free supply of voltage-sensitive loads

38 PHOENIX CONTACT
PHOENIX CONTACT 39
QUINT inverters

For generating alternating current


With the new DC/AC inverter in the increased power. A three-phase grid can be
QUINT POWER family, a compact solution created, for example for operating alternating
is now available for the first time to generate current drives, by connecting three inverters
alternating current in DC applications. in parallel.
Connect two DC/AC inverters in parallel to
Web code: #2426
create a redundant system or to benefit from

Your advantages
Manual selection of AC output voltage via a signal
terminal enables use worldwide
A pure sine curve at the output
USB interface for connection to industrial PCs, for
example
Can be switched in parallel for various applications
Space savings, thanks to compact design

40 PHOENIX CONTACT
QUINT DC/AC inverters

Input 20 V DC ... 30 V DC


W x H x D in mm 180 x 130 x 125

480 W / 600 VA New


Type QUINT4-INV/24DC/1AC/600VA/USB
Order No. 1067325

Parallel connection with synchronized AC output


You can connect two devices in parallel.
This increases the operational safety of
your systems in the event of a power supply
failure (redundancy) or it gives you the
option to increase the power. The output
power can be doubled by using the DC/AC
inverter. Communication between the two
24 V DC
devices synchronizes the phase relation in
PE
both operating modes.

L / N / PE
e.g. 230 V AC

Three-phase grid for a drive application


Connect three devices in parallel to
create a three-phase grid. The inverters
communicate with each other in order to
synchronize the 120° phase shift in real
time. This allows alternating current drives
to be operated.

24 V DC
PE

L1 / L2 / L3
e.g. 400 V AC

PHOENIX CONTACT 41
Redundancy modules
Redundant power supply solutions are necessary in applications with the highest
demands on operational safety. They ensure that the failure of one power supply unit
does not result in system downtime.
A redundant system is the result of the parallel connection of two power supply units
that are decoupled from one another. This decoupling via an active redundancy module
or a simple diode ensures the high availability and productivity of your system.

42 PHOENIX CONTACT
PHOENIX CONTACT 43
Redundancy modules

QUINT SINGLE ORING


With the QUINT S-ORING you can increase monitored continuously. The Plus version and
Web code: #2180
your system availability and operational safety the VP version with protective circuit and
even further. Supply networks are decoupled overvoltage protection protect sensitive loads.
and lines are disconnected continuously Overvoltages are limited to <28.8 V DC or
while they are routed to the load. In <30 V DC respectively.
combination with the fourth generation of
the QUINT POWER power supplies, the
input voltage and decoupling section are

Your advantages
Consistent redundancy through to the load
Constant monitoring of input voltage and decoupling
path
Energy savings of 70% with decoupling with MOSFET
Protection against overvoltages at the output
(overvoltage protection) increases the operational
safety
Protective coating with ATEX and IECEx approval for
extreme ambient conditions

44 PHOENIX CONTACT
QUINT ORING with ACB Technology (Auto Current Balancing)
• Even load distribution for redundant The ACB Technology extends the service lower level of power dissipation ensures
power supplies life of redundantly operated power supplies that all the control cabinet components stay
• Lower thermal load on both power by evenly utilizing the power supply units. cooler and the service life of devices in the
supplies As a result of asymmetries, the load is often redundant system is doubled.
• Service life of the redundant solution is supplied by just one power supply unit,
doubled while the other power supply unit runs in
no-load operation. This results in a thermal
load on the working power supply unit and,
therefore, rapid aging. Thanks to the use of
modern MOSFET technology, the resulting
thermal load is reduced by up to 70%. This

Designed by PHOENIX CONTACT

QUINT ORING active redundancy modules with ACB Technology


The three QUINT ORING modules feature
ACB Technology and preventive function
monitoring. The input voltage, output Auto Current Balancing Technology
current, and decoupling path are monitored Designed by PHOENIX CONTACT
continuously, so a loss of redundancy can
be reported early on. Two positive output
terminals ensure consistent redundancy
through to the load. The installed MOSFETS 50% 50%
reduce the power dissipation to an extent power power
that energy savings of around 70% are
achieved. Overvoltage protection limits
overvoltages to 32 V DC.

Detect and avoid critical states IIN1= 2.5 A

The QUINT ORING modules monitor However, there is no longer any


the load current and generate a warning as redundancy: if one of the two power
13 14 23 24

IN1 IN2
Input DC 24V 2x10A

IOUT= 5 A
OK

soon as a set value is exceeded. If the user supplies fails, the second device is no longer Redundancy
OK

Redundancy OK
connects additional loads to a redundant able to provide 8 A. The LED immediately
QUINT ORING

I<In

10A
In

power supply as part of a system extension, warns the system operator that there is no
5A 20A

Output DC 20A

this can result in a loss of redundancy. longer any redundancy.


IIN2= 2.5 A
This is illustrated in the example scenario
described below.

Two redundant power supplies, each with IIN1= 4 A


5 A nominal current, supply a controller
with the 5 A required.
13 14 23 24

IN1 IN2
Input DC 24V 2x10A

IOUT= 8 A Message:


OK

If an additional load of 3 A is now Redundancy

Redundancy
OK

connected, it can be supplied by the power


QUINT ORING

not OK
I<In

10A
In
5A 20A

supply’s power reserve. The required Output DC 20A

current of 8 A will be supplied without a


voltage dip. IIN2= 4 A

PHOENIX CONTACT 45
Active redundancy modules

Our 1- or 2-channel active redundancy AC feed-in to the the DC load. By continually reduces the thermal loads due to self-heating
module versions monitor themselves and monitoring the AC and DC voltage levels, to a minimum.
the connection wiring through to the load. the respective wiring, and at the same time,
In combination with a QUINT POWER the decoupling of the load current, critical
supply, you can extend the system to include operating states can be detected and signaled
complete redundancy monitoring from the early on. The integrated MOSFET technology

Decoupling and monitoring Power supply 1


Active, single-channel redundancy module
Load
for the separate structuring of a redundant
system. In combination with the new Power supply 2
QUINT POWER power supplies, your system
is monitored continuously.

QUINT S-ORING

Input 8 V DC ... 30 V DC 8 V DC ... 27.5 V DC 8 V DC ... 26 V DC
W x H x D in mm 32 x 130 x 125 32 x 130 x 125 32 x 130 x 125

12 V … 24 V / 1 x 40 A 12 V … 24 V / 1 x 40 A /VP* 12 V … 24 V / 1 x 40 A / +**
Type QUINT4-ORING/12-24DC/1x40 QUINT4-S-ORING/12-24DC/1x40/VP QUINT4-ORING/12-24DC/1x40/+
Order No. 2907752 1043418 2907753

* Overvoltages arising are limited to 30 V, ** overvoltages arising are limited to 28.8 V

Decoupling, monitoring, and control Power supply 1


Active redundancy module for decoupling power
Load
supplies. With monitoring of the input voltage,
wiring, and load current.
Power supply 2

QUINT ORING Auto Current Balancing Technology


Designed by PHOENIX CONTACT

Input 18 V DC ... 28 V DC 18 V DC ... 28 V DC 18 V DC ... 28 V DC
W x H x D in mm 32 x 130 x 125 38 x 130 x 125 66 x 130 x 125

24 V/2 x 10 A/1 x 20 A 24 V/2 x 20 A/1 x 40 A 24 V/2 x 40 A/1 x 80 A


Type QUINT-ORING/24DC/2x10/1x20 QUINT-ORING/24DC/2x20/1x40 QUINT-ORING/24DC/2x40/1x80
Order No. 2320173 2320186 2902879

46 PHOENIX CONTACT
Passive redundancy modules

Passive redundancy modules enable simple second power supply automatically takes over connecting cables through to the DC load are
decoupling of two power supplies on the the entire supply for the DC load. The diode not monitored.
DC side. This is useful in particular when power losses arising during operation are
power supplies are connected in parallel to dissipated completely as thermal energy to
increase power or for redundancy purposes. the control cabinet. The diode is not subject
If one device fails due to malfunctions, the to preventive function monitoring, and the

Decoupling via diodes Power supply 1


Simple decoupling via diodes.
Load

Power supply 2

QUINT DIODE

Input 10 V DC ... 30 V DC 30 V DC ... 56 V DC


W x H x D in mm 50 x 130 x 125 50 x 130 x 125

12 V … 24 V / 2 x 20 A / 1 x 40 A 48 V/2 x 20 A/1 x 40 A


Type QUINT4-DIODE/12-24DC/2x20/1X40 QUINT4-DIODE/48DC/2x20/1X40
Order No. 2907719 2907720

TRIO DIODE UNO DIODE STEP DIODE

Input 10 V DC ... 30 V DC 10 V DC ... 30 V DC 4.5 V DC ... 30 V DC 4.5 V DC ... 30 V DC
W x H x D in mm 35 x 130 x 115 41 x 130 x 115 22.5 x 90 x 84 18 x 90 x 61

12 V … 24 V / 2 x 10 A / 12 V … 24 V / 2 x 20 A / 5 V … 24 V / 2 x 10 A / 5 V … 24 V / 2 x 5 A /
1 x 20 A 1 x 40 A 1 x 20 A 1 x 10 A
TRIO2-DIODE/ TRIO2-DIODE/ UNO-DIODE/ STEP-DIODE/
Type
12-24DC/2x10/1x20 12-24DC/2x20/1x40 5-24DC/2x10/1x20 5-24DC/2x5/1x10
Order No. 2907380 2907379 2905489 2868606

Monitored
Not monitored

PHOENIX CONTACT 47
Uninterruptible power supplies
Mains interruptions can have serious consequences. Do not take any risks. You can rely
on our uninterruptible power supplies.
We provide the following solutions for high system availability, even in the event of a
mains failure:
• DC and AC UPS modules with communication interfaces
• UPS modules with integrated power supply or energy storage system
• Comprehensive selection of energy storage systems

48 PHOENIX CONTACT
PHOENIX CONTACT 49
Uninterruptible power supplies

IQ Technology for an intelligent UPS system


Superior system availability, thanks to IQ Technology:
• You know the state of charge and remaining runtime of your energy storage system
• You will be warned of pending failures at an early stage, making it possible to plan
servicing
• You can increase the service life of the energy storage system
• All relevant information is available to you on your industrial PC and higher-level
controllers

Web code: #0154

IQ Technology
Designed by PHOENIX CONTACT

Uninterruptible power supply units with IQ Technology


• Battery management system (BMS) with optimize its service life, and warn of The intelligent battery management system
IQ Technology pending failures in good time. All relevant calculates the remaining runtime available.
• Provides information on the remaining information is transferred to higher-level It advises as soon as a threshold value is
runtime, state of charge, and service life computers and controllers. reached. In this way, your system works as
of the energy storage system long as possible and is shut down before the
• Optimizes the charging characteristic for The intelligent UPS with IQ Technology battery voltage runs out.
an even longer service life monitors and optimizes the energy storage,
• Interfaces enable integration into any reduces the maintenance effort, and
industrial network increases the availability of your systems.
It determines all relevant energy storage
Uninterruptible power supplies (UPS) states. This ensures the crucial transparency
continue to deliver power even in the required to guarantee the stability of the
event of a mains failure. Thanks to our supply and the best possible utilization of
IQ Technology, you're one step ahead: the energy storage system at all times.
they advise on the charging state and the
remaining runtime of the energy storage,

50 PHOENIX CONTACT
Intelligent charging
Intelligent battery management
Adapts the charging current and
SOC (State of Charge)
thereby ensures fast recharging and
Describes the current state of charge and the
availability.
remaining energy storage system runtime.

Intelligent battery control


Detects the connected battery type and
increases its remaining service life by optimally
adapting the charging characteristic.

Intelligent battery management


SOH (State of Health)
Reports on the life remaining for the
energy storage device, and warns of
pending failures in good time. Interfaces
Easy integration into industrial networks:
• PROFINET
• EtherNet/IP™
• EtherCAT®
• USB

PHOENIX CONTACT 51
QUINT DC UPS uninterruptible power
supplies – intelligent and communicative
With the intelligent QUINT DC UPS for integration into existing industrial networks,
you are ready for Industrie 4.0. With the QUINT DC UPS and the integrated
interfaces for PROFINET, EtherNet/IP™, EtherCAT®, and USB, monitoring,
configuration, and shutting the system down in a safe state are possible at all times and
anywhere in the world.

Signaling The USB interface is suitable for


LEDs and floating relay contacts provide • Monitoring and configuration with UPS-CONF
function monitoring. QUINT UPS • Safe shutdown of industrial PCs with optimum utilization of the
supplies the following information via energy storage system
the wired contacts: • Automatic startup when mains returns
• The load is being supplied by the
energy storage system
• The energy storage system is being
charged
• An alarm is present

Intelligent monitoring of the


energy storage system
• Automatic detection of the battery
type connected and service life
increase thanks to adaptive charging
characteristics
• Adapting the charging current ensures
fast recharging and availability of the
energy storage system

52 PHOENIX CONTACT
The first intelligent QUINT DC UPS for integration into established industrial networks
Interfaces Extended load management
The QUINT DC-UPS can be easily The extended load management system
integrated into the following existing consists of the following functions:
industrial networks via various interfaces: • Energy monitoring – monitoring input
• PROFINET and output voltages and the associated
• EtherNet/IP™ currents
• EtherCAT® • PC shutdown function – reliable
shutdown of your industrial PC in the
All network technologies, devices with USB event of a mains failure without data loss,
interface, and devices without an interface and automatic restart of the industrial PC
are available in all four performance classes when the mains power returns
(5 A, 10 A, 20 A, and 40 A). • Cold-start function – UPS startup even
without mains power
2-port switch Device descriptions
Our QUINT DC UPS has a 2-port switch. Function blocks If the appropriate function block for your
The device can therefore be integrated We include the corresponding function application is not available, you can create
flexibly into existing industrial networks. blocks for the following engineering your own custom function blocks using our
environments so that the QUINT DC UPS device descriptions.
can be started up quickly:
• PLCnext
• TIA Portal
• Studio 5000
• TwinCAT

UPS-CONF configuration and management software


The software is available free of charge as a download on the
Phoenix Contact website under "Downloads" on the QUINT-UPS/...
product pages.

Integrated data recorder Configuration Preventive function monitoring


The log file archives events, e.g., when and for Flexible adaptation of the QUINT UPS All relevant operating parameters are
how long the QUINT UPS has bridged mains behavior to individual requirements. displayed graphically. Important messages
failures. appear in the foreground.

PHOENIX CONTACT 53
Uninterruptible power supplies

Intelligence in any combination


Create your own individual QUINT DC-UPS solution – tailored to your application:
1. Choose your power supply
2. Choose your UPS module
3. Choose your energy storage system

Intelligence for increasing system availability


Task Solution with QUINT UPS The QUINT UPS indicates whether the
Supply an industrial PC consistently with The intelligent QUINT UPS determines all remaining buffer time is actually still
24 V DC. relevant energy storage system states. This 20 minutes. As soon as an adjustable
ensures the crucial transparency required threshold value has been reached, a
Previous solution to guarantee the stability of the supply and warning message is sent via signal contact,
One UPS with 3.4 Ah buffers 24 V DC / 5 A to optimize utilization of the energy storage via software, or directly to higher-level
for 20 minutes under optimal conditions. system at all times. controllers.
Can the energy storage system actually The intelligent battery management
bridge this time? The state of charge, detects the current state of charge of the
performance, and remaining runtime of the connected energy storage system and
energy storage system are unknown. uses it to calculate the remaining runtime
available.

54 PHOENIX CONTACT
~ ~ ~ + –+ –+ –

Power supply UPS module Energy storage systems

PHOENIX CONTACT 55
Uninterruptible power supplies

QUINT UPS for DC and AC applications


The QUINT UPS for 24 V DC with output currents of 5 to 40 A is suitable for mains
interruptions that last for up to several hours.
The QUINT UPS for AC applications delivers a pure sine curve at the output. The sine
wave generated during battery operation is synchronized to the grid previously used
for supply. Only one energy storage system is required to safeguard your system.

IQ Technology
Designed by PHOENIX CONTACT

Substantial power reserve


• For mains and battery operation
• Power Boost static power reserve
• SFB Technology (Selective Fuse Breaking,
page 11)

Adaptive current management


• For fast recharging and high energy storage
system availability

Easy integration into industrial


networks thanks to interfaces
• PROFINET
• EtherNet/IP™
• EtherCAT®
• USB

Web code: #1992 Web code: #1988

56 PHOENIX CONTACT
Seamless transition, thanks to online Comprehensive signaling and
topology configuration
• Classification in accordance with • Floating relay contacts
EN 62040-3: VFI-SS-111 • Signal contacts

Convection cooling
• Fan-free heat dissipation

Startup from the energy storage system


• Possible even without power supply input

Can be switched in parallel


• For redundancy and increased
performance

USB interface
• For connection to industrial PCs
and controllers

Optimized use of the buffer


time and preventive monitoring
of the energy storage system
• Intelligent battery management

PHOENIX CONTACT 57
Uninterruptible power supplies

Energy storage systems for QUINT UPS


With the energy storage systems for our modular system of uninterruptible power
supplies, you will always have the right solution for your system.
• UPS-BAT/LI-ION for a long service life
• UPS-BAT/VRLA-WTR for use in extreme ambient temperatures
• UPS-BAT/VRLA for longer buffer times

Your advantages
Fast installation thanks to automatic detection of
the energy storage system and tool-free replacement
during operation
Constant communication with QUINT UPS for
continuous monitoring and intelligent management
Extremely long service life with optimized charging
characteristics based on the technology and the
ambient conditions UPS-BAT/LI-ION...
Immediate availability: all energy storage systems leave • Long service life with long buffer times
our warehouse fully charged • Lithium iron phosphate technology

58 PHOENIX CONTACT
Typical Service life Service life Charging cycles Weight
Type Temperature
buffer time at +20°C at +50°C at +20°C (standardized)
UPS-BAT/LI-ION… >40 min -20°C ... +58°C 15 years 2 years 7,000 0.45 kg
UPS-BAT/VRLA-WTR… >5 h -25°C ... +60°C 12 years 1.5 years 300 1.3 kg
UPS-BAT/VRLA… >8 h 0°C ... +40°C 6 years … 9 years 1 year 250 1 kg

Particularly good product characteristics

UPS-BAT/VRLA-WTR... UPS-BAT/VRLA...
(Valve Regulated Lead Acid / (Valve Regulated Lead Acid)
Wide Temperature Range) • Longer buffer times
• Longer buffer times at extreme • Lead AGM technology (Absorbent
temperatures Glass Mat)
• Pure lead AGM technology (Absorbent
Glass Mat)

PHOENIX CONTACT 59
Uninterruptible power supplies

QUINT DC UPS with IQ Technology – for industrial networks


The first intelligent UPS with integrated UPS module, and energy storage system. With
Web code: #1992
Ethernet interface for integration into IQ Technology and a powerful battery charger,
established industrial networks. The UPS the battery management system (BMS)
modules for 24 V DC with output currents ensures superior system availability.
ranging from 5 to 40 A allow you to create a
custom solution combining a power supply,

Your advantages
Evaluation of the state of health (SOH) and state
of charge (SOC), thanks to the intelligent battery
management system (BMS)
Automatic recognition of the battery capacities and
technologies (VRLA, WTR, LiFePO4)
Monitoring of output current and voltage, as well as
manual connection and disconnection of the system
SFB Technology selectively trips standard miniature
circuit breakers; loads connected in parallel continue
working

60 PHOENIX CONTACT
QUINT DC UPS* IQ Technology
Designed by PHOENIX CONTACT

W x H x D in mm 35 x 130 x 125 35 x 130 x 125 40 x 130 x 125 47 x 130 x 125

24 V / 5 A/ PN 24 V / 10 A/ PN 24 V / 20 A/ PN 24 V / 40 A/ PN


QUINT4-UPS/24DC/24DC/5/ QUINT4-UPS/24DC/24DC/10/ QUINT4-UPS/24DC/24DC/20/ QUINT4-UPS/24DC/24DC/40/
Type PROFINET
PN PN PN PN
Order No. 2906993 2907068 2907073 2907079
24 V / 5 A / EIP 24 V / 10 A / EIP 24 V / 20 A / EIP 24 V / 40 A / EIP
QUINT4-UPS/24DC/24DC/5/ QUINT4-UPS/24DC/24DC/10/ QUINT4-UPS/24DC/24DC/20/ QUINT4-UPS/24DC/24DC/40/
Type EtherNet/IP™
EIP EIP EIP EIP
Order No. 2906994 2907069 2907074 2907080
24 V / 5 A / EC 24 V / 10 A / EC 24 V / 20 A / EC 24 V / 40 A / EC
QUINT4-UPS/24DC/24DC/10/ QUINT4-UPS/24DC/24DC/20/ QUINT4-UPS/24DC/24DC/40/
Type EtherCAT® QUINT4-UPS/24DC/24DC/5/EC
EC EC EC
Order No. 2906996 2907070 2907076 2907081
24 V / 5 A / USB 24 V / 10 A / USB 24 V / 20 A / USB 24 V / 40 A / USB
QUINT4-UPS/24DC/24DC/5/ QUINT4-UPS/24DC/24DC/10/ QUINT4-UPS/24DC/24DC/20/ QUINT4-UPS/24DC/24DC/40/
Type USB
USB USB USB USB
Order No. 2906991 2907067 2907072 2907078
24 V / 5 A 24 V / 10 A 24 V / 20 A 24 V / 40 A
Type without
QUINT4-UPS/24DC/24DC/5 QUINT4-UPS/24DC/24DC/10 QUINT4-UPS/24DC/24DC/20 QUINT4-UPS/24DC/24DC/40
interface
Order No. 2906990 2907066 2907071 2907077

QUINT CHARGER
QUINT DC UPS* IQ Technology
Additional charger for increasing the charging
with dual output Designed by PHOENIX CONTACT
current

W x H x D in mm 60 x 130 x 126 W x H x D in mm 35 x 130 x 125

24 V / 10 A New 12 V / 5 A 12 V / 5 A; 24 V / 10 A


Type QUINT4-CHARGER/1AC/24DC/10 Type QUINT-UPS/24DC/12DC/5/24DC/10
Order No. 2907990 Order No. 2320461

* These devices support SFB Technology.

PHOENIX CONTACT 61
Selection guide for QUINT DC UPS and energy storage system

Select the appropriate combination of QUINT DC UPS and energy storage system here.

~ + –

Power supply UPS module Energy storage


systems

UPS-BAT/LI-ION UPS-BAT/VRLA-WTR

+ –

W x H x D in mm 135 x 202 x 110 264 x 224 x 197 172 x 177 x 178 358 x 174 x 169

120 Wh 924 Wh 13 Ah 26 Ah


UPS-BAT/VRLA-WTR/ UPS-BAT/VRLA-WTR/
Type UPS-BAT/LI-ION/24DC/120WH UPS-BAT/LI-ION/24DC/924WH
24DC/13AH 24DC/26AH
Order No. 2320351 2908232 2320416 2320429

Buffer times for your QUINT DC UPS with the following energy storage systems: LI-ION, and VRLA-WTR

Select your energy storage system for Buffer time


24 V DC applications here. Example: 20 A is Load Seconds Minutes Hours
to be buffered for 6 minutes. current 10 15 30 1 2 3 5 6 7 8 9 10 20 30 40 45 50 1 2 3 5 8 10 15 20
1A
2A 1+1 1+1
3A 1+1 1+1
5A 1+1 1+1
7A 1+1 1+1
QUINT4-UPS/24DC/24DC/20A and 10 A 1+1 1+1
15 A 1+1 1+1
UPS-BAT/LI-ION/24DC/120WH 20 A 1+1
25 A 1+1 1+1
30 A 1+1 1+1 1+1
35 A 1+1 1+1 1+1 1+1
40 A 1+1 1+1 1+1 1+1
1+1: Two energy storage systems of the same capacity are required in this case. The data is based on an
ambient temperature of +20°C.

62 PHOENIX CONTACT
IQ Technology … with dual
QUINT DC UPS Designed by PHOENIX CONTACT output

~ + –

W x H x D in mm 35 x 130 x 125 35 x 130 x 125 40 x 130 x 125 47 x 130 x 125 35 x 130 x 125

24 V / 5 A 24 V / 10 A 24 V / 20 A 24 V / 40 A 12 V / 5 A; 24 V / 10 A
QUINT4-UPS QUINT4-UPS QUINT4-UPS QUINT4-UPS QUINT-UPS
Type
24DC/24DC/5... 24DC/24DC/10... 24DC/24DC/20... 24DC/24DC/40... 24DC/12DC/5/24DC/10
Recommended LI-ION LI-ION LI-ION LI-ION 924WH
LI-ION
energy storage VRLA-WTR VRLA-WTR VRLA-WTR VRLA-WTR
VRLA/1.3 ... 38 AH
system VRLA/1.3 ... 12 AH VRLA/1.3 ... 38 AH VRLA/3.4 ... 38 AH VRLA/7.2 ... 38 AH
(max. 60 AH)
UPS-BAT/... (max. 40 AH) (max. 80 AH) (max. 100 AH) (max. 100 AH)

These devices support SFB Technology.

UPS-BAT/VRLA

+ –

W x H x D in mm 54 x 157 x 113 85 x 191 x 110 135 x 202 x 110 202 x 202 x 110 152 x 167 x 181 330 x 221 x 197

1.3 Ah 3.4 Ah 7.2 Ah 12 Ah 20 Ah New 38 Ah

UPS-BAT/VRLA/ UPS-BAT/VRLA/ UPS-BAT/VRLA/ UPS-BAT/VRLA/ UPS-BAT/VRLA/ UPS-BAT/VRLA/


Type
24DC/1.3AH 24DC/3.4AH 24DC/7.2AH 24DC/12AH 24DC/20AH 24DC/38AH

Order No. 2320296 2320306 2320319 2320322 1109004 2320335

Buffer times for your QUINT DC UPS with VRLA energy storage systems

Select your energy storage system for Buffer time


24 V DC applications here. Example: 7 A is Load Minutes Hours
to be buffered for one hour. current 1 2 3 5 6 7 8 9 10 20 30 40 45 50 1 2 3 5 8 10 15 20
1A
2A 1+1 1+1
3A 1+1 1+1
5A 1+1 1+1
7A 1+1 1+1
QUINT4-UPS/24DC/24DC/10A and 10 A 1+1 1+1
15 A 1+1 1+1
UPS-BAT/VRLA/24DC/12AH 20 A 1+1
25 A 1+1 1+1
30 A 1+1 1+1 1+1
35 A 1+1 1+1 1+1 1+1
40 A 1+1 1+1 1+1 1+1
1+1: Two energy storage systems of the same capacity are required in this case. The data is based on an
ambient temperature of +20°C.

PHOENIX CONTACT 63
Selection guide for QUINT AC-UPS/500VA and energy storage system

Select the appropriate combination of QUINT AC-UPS/500VA and energy storage system here.

~ + –

Power supply UPS module Energy storage


systems

UPS-BAT/LI-ION UPS-BAT/VRLA-WTR

+ –

W x H x D in mm 135 x 202 x 110 264 x 224 x 197 172 x 177 x 178 358 x 174 x 169

120 Wh 924 Wh 13 Ah 26 Ah


UPS-BAT/VRLA-WTR/ UPS-BAT/VRLA-WTR/
Type UPS-BAT/LI-ION/24DC/120WH UPS-BAT/LI-ION/24DC/924WH
24DC/13AH 24DC/26AH
Order No. 2320351 2908232 2320416 2320429

Buffer times for your QUINT AC-UPS/500VA with the following energy storage systems: LI-ION, and
VRLA-WTR
Select your energy storage system for Buffer time
your QUINT AC-UPS/500VA (120 / 230 V Seconds Minutes Hours
application). Power 0.2 0.4 2 8 15 20 40 1 2 3 5 10 20 30 40 45 50 1 2 3 5 8 10 15 20
Example: 125 W is to be buffered for one 15 W 1+1
hour. 35 W 1+1 1+1
55 W 1+1 1+1
90 W 1+1 1+1
125 W 1+1 1+1 1+1
180 W 1+1 1+1
275 W 1+1 1+1
400 W 1+1 1+1
QUINT4-UPS/1AC/1AC/500VA/USB
and UPS-BAT/VRLA-WTR/24DC/26AH 1+1: Two energy storage systems of the same capacity are required in this case. The data is based on an
ambient temperature of +20°C.

64 PHOENIX CONTACT
QUINT AC UPS 1~ IQ Technology Accessories Web code: #1988
Designed by PHOENIX CONTACT

~ + –

W x H x D in mm 180 x 130 x 125

400 W/500 VA New USB data cable


Type QUINT4-UPS/1AC/1AC/500VA/USB MINI-SCREW-USB-DATACABLE
Order No. 1067327 2908217

Recommended
LI-ION For communication between the UPS
energy storage
VRLA-WTR module and the UPS-CONF, length 3 m
system
VRLA/3.4 ... 38 AH
1 x UPS-BAT/...

UPS-BAT/VRLA

+ –

W x H x D in mm 85 x 191 x 110 135 x 202 x 110 202 x 202 x 110 152 x 167 x 181 330 x 221 x 197

3.4 Ah 7.2 Ah 12 Ah 20 Ah New 38 Ah


UPS-BAT/VRLA/ UPS-BAT/VRLA/ UPS-BAT/VRLA/ UPS-BAT/VRLA/ UPS-BAT/VRLA/
Type
24DC/3.4AH 24DC/7.2AH 24DC/12AH 24DC/20AH 24DC/38AH
Order No. 2320306 2320319 2320322 1109004 2320335

Buffer times for QUINT AC-UPS/500VA with VRLA energy storage systems

Select your energy storage system for Buffer time


your QUINT AC-UPS/500VA (120 / 230 V Minutes Hours
application). Power 1 2 3 5 10 20 30 40 45 50 1 2 3 5 8 10 15 20
Example: 125 W is to be buffered for one 15 W 1+1
hour. 35 W 1+1
55 W 1+1
90 W 1+1
125 W 1+1 1+1
180 W 1+1
275 W 1+1 1+1
400 W 1+1
QUINT4-UPS/1AC/1AC/500VA/USB
and UPS-BAT/VRLA/24DC/20AH 1+1: Two energy storage systems of the same capacity are required in this case. The data is based on an
ambient temperature of +20°C.

PHOENIX CONTACT 65
Selection guide for QUINT AC-UPS/1kVA and energy storage system

Select the appropriate combination of QUINT AC-UPS/1kVA and energy storage system here.

~ + –

Power supply UPS module Energy storage


systems

UPS-BAT/LI-ION UPS-BAT/VRLA-WTR

+ –

W x H x D in mm 135 x 202 x 110 264 x 224 x 197 172 x 177 x 178 358 x 174 x 169

120 Wh 924 Wh 13 Ah 26 Ah


UPS-BAT/LI-ION/ UPS-BAT/VRLA-WTR/ UPS-BAT/VRLA-WTR/
Type UPS-BAT/LI-ION/24DC/924WH
24DC/120WH 24DC/13AH 24DC/26AH
Order No. 2320351 2908232 2320416 2320429

Buffer times for your QUINT AC-UPS/1kVA with the following energy storage systems: LI-ION, and
VRLA-WTR
Select your energy storage system for Buffer time
your QUINT AC-UPS/1kVA (120 / 230 V Minutes Hours
application). Power 2 3 4 5 8 10 15 20 25 30 40 50 1 1.5 2 3 4 6 9 10
Example: 400 W is to be buffered for three 100 W 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1
hours. 200 W 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1
300 W 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1
400 W 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1
500 W 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1
600 W 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1
700 W 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1
800 W 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1
QUINT4-UPS/1AC/1AC/1KVA and 900 W 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1
2 x UPS-BAT/LI-ION/24DC/924WH
1+1: For the QUINT AC-UPS/1kVA, two energy storage systems of the same capacity are always required.
The data is based on an ambient temperature of +20°C.

66 PHOENIX CONTACT
QUINT AC UPS 1~ IQ Technology Accessories Web code: #1988
Designed by PHOENIX CONTACT

~ + –

W x H x D in mm 290 x 130 x 125

900 W / 1 kVA USB data cable


Type QUINT4-UPS/1AC/1AC/1KVA MINI-SCREW-USB-DATACABLE
Order No. 2320283 2908217

Recommended
energy storage LI-ION For communication between the UPS
system VRLA-WTR module and the UPS-CONF, length 3 m
2 x UPS-BAT/... VRLA/3.4 ... 38 AH

UPS-BAT/VRLA

+ –

W x H x D in mm 85 x 191 x 110 135 x 202 x 110 202 x 202 x 110 152 x 167 x 181 330 x 221 x 197

3.4 Ah 7.2 Ah 12 Ah 20 Ah New 38 Ah


UPS-BAT/VRLA/ UPS-BAT/VRLA/ UPS-BAT/VRLA/ UPS-BAT/VRLA/ UPS-BAT/VRLA/
Type
24DC/3.4AH 24DC/7.2AH 24DC/12AH 24DC/20AH 24DC/38AH
Order No. 2320306 2320319 2320322 1109004 2320335

Buffer times for your QUINT AC-UPS/1kVA with VRLA energy storage systems:

Select your energy storage system for Buffer time


your QUINT AC-UPS/1kVA (120 /230 V Minutes Hours
application). Power 2 3 4 5 8 10 15 20 25 30 40 50 1 1.5 2 3 4 6 9 10
Example: 400 W is to be buffered for 100 W 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1
50 minutes. 200 W 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1
300 W 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1
400 W 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1
500 W 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1
600 W 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1
700 W 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1
800 W 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1
QUINT4-UPS/1AC/1AC/1KVA and 900 W 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1 1+1
2 x UPS-BAT/VRLA/24DC/12AH
1+1: For the QUINT AC-UPS/1kVA, two energy storage systems of the same capacity are always required.
The data is based on an ambient temperature of +20°C.

PHOENIX CONTACT 67
Selection guide for QUINT UPS modules with integrated energy storage system

Buffer modules QUINT CAP QUINT UPS


QUINT CAP for cyclic failures lasting up to
The QUINT CAP and QUINT BUFFER are several minutes. Your PC can be shut down Space saving and easy to install in existing
both suitable for the DIN rail and combine an conveniently thanks to the USB interface. systems. Simply connect a 24 V DC power
electronic switch-over unit and maintenance- supply unit upstream, and the UPS solution
free, capacitor-based energy storage system in is complete. Utilize the benefits of IQ
the same housing. QUINT BUFFER Technology and the minimum wiring outlay.
The compact buffer module for bridging The maintenance-free energy storage device is
failures within seconds. integrated.

Web code: #1989

~ + –

Power supply UPS module Energy storage


systems

QUINT CAP QUINT CAP Accessories

~ + –

Input 22.5 V DC ... 30 V DC 22.5 V DC ... 30 V DC 22.5 V DC ... 30 V DC
W x H x D in mm 85 x 102.5 x 90 94 x 130 x 125 118 x 130 x 125 Length: 3 m

24 DC / 3,8 A New 24 DC / 5 A 24 DC / 10 A USB data cable
QUINT4-CAP/ QUINT4-CAP/ QUINT4-CAP/ MINI-SCREW-USB-
Type
24DC/3.8/1KJ/PT 24DC/5/4KJ 24DC/10/8KJ DATACABLE
Order No. 2320526 2320539 2320571 2908217

Energy storage system based For communication between


Energy storage system based on maintenance-free double-
Information on maintenance-free double- the UPS module and the
layer capacitors
layer capacitors industrial PC

These devices support SFB Technology.

Buffer times for QUINT CAP


Example: 5 A is to be buffered for Buffer time
Load Seconds Minutes
40 seconds.
current 9 10 15 20 30 40 50 1 2 3 5 10 30 40
0.05 A
0.50 A
1.00 A
2.00 A
QUINT4-CAP/24DC/10/8KJ 2.50 A
3.80 A
5.00 A
6.25 A
7.50 A
10.00 A
12.50 A
The data is based on an ambient temperature of +25°C.

68 PHOENIX CONTACT
IQ Technology
QUINT UPS Designed by PHOENIX CONTACT

~ + –

Input 18 V DC ... 30 V DC 18 V DC ... 30 V DC


W x H x D in mm 88 x 138 x 125 120 x 169 x 125

24 DC / 5 A / 1.3 Ah 24 DC / 10 A / 3.4 Ah


QUINT-UPS/ QUINT-UPS/
Type
24DC/24DC/5/1.3AH 24DC/24DC/10/3.4AH
Order No. 2320254 2320267
Energy storage systems Lead AGM technology Lead AGM technology
Information Integrated temperature sensor optimizes charging currents, thereby increasing the service life
These devices support SFB Technology.

QUINT BUFFER

~ + –

Input 22.5 V DC ... 30 V DC 22.5 V DC ... 30 V DC


W x H x D in mm 57 x 130 x 125 73 x 130 x 125

24 V / 20 A 24 V / 40 A


QUINT4-BUFFER/ QUINT4-BUFFER/
Type
24DC/20 24DC/40
Order No. 2907913 2908283

Information Energy storage system based on maintenance-free electrolytic capacitors

These devices support SFB Technology.

Buffer times for QUINT UPS and QUINT BUFFER


Example: 5 A is to be buffered for Buffer time
Seconds Minutes Hours
20 minutes. Power 0.2 0.4 0.5 1 1.5 2 4 6 8 16 30 1 2 3 5 6 7 8 9 10 15 20 25 30 40 45 50 1 2 3
0.5 A
1A
2A
3A
QUINT4-UPS/24DC/24DC/10/3.4AH 5A
7A
10 A
20 A
30 A
40 A
The data is based on an ambient temperature of +20°C.

PHOENIX CONTACT 69
Selection guide for UPS modules with integrated energy storage system

Particularly space-saving TRIO AC UPS UNO UPS


UPS module and energy storage system The TRIO AC UPS with Push-in Technology The compact and narrow UNO UPS with
combined in one housing. Just one power for the DIN rail saves space and reliably integrated lead AGM energy storage system
supply needs to be connected upstream. supplies your AC loads. It delivers a pure sine ensures long buffer times.
curve at the output. The sine wave generated
The energy storage systems can be replaced during battery operation is synchronized to STEP UPS
quickly and easily when they reach the end of the grid previously used for supply. Connected
their service life. industrial PCs can be shut down via the The STEP DC UPS has been designed
integrated USB interface. specifically for use in distribution boards. It
requires a space of just 108 mm on the DIN
rail.
Web code: #1987

Web code: #1990

TRIO AC UPS 1~ Accessories

~ + –

Input 184 V AC ... 264 V AC 96 V AC ... 138 V AC


W x H x D in mm 210 x 169 x 139 210 x 169 x 139 Length: 3 m

230 V / 750 VA 120 V / 750 VA USB data cable


TRIO-UPS-2G/ TRIO-UPS-2G/ MINI-SCREW-
Type
1AC/1AC/230V/750VA 1AC/1AC/120V/750VA USB-DATACABLE
Order No. 2905909 2905908 2908217

Energy storage system with Energy storage system with For communication between UPS
Information
lead AGM technology lead AGM technology module and UPS-CONF

Buffer times for TRIO AC UPS


1+1: An additional energy storage system Buffer time
Minutes Hours
of the same capacity (3.4 Ah) of type Power 1 1.5 2 4 6 8 10 15 20 30 40 50 1 1.5
UPS-BAT/VRLA/24DC/3.4AH (2320306) 50 W 1+1 1+1 1+1
or QUINT-BAT/24DC/3.4AH (2866349) is 100 W 1+1 1+1 1+1
required in this case. 150 W 1+1 1+1 1+1
200 W 1+1 1+1 1+1
250 W 1+1 1+1 1+1
300 W 1+1 1+1 1+1
400 W 1+1 1+1 1+1
500 W 1+1 1+1 1+1
600 W 1+1 1+1 1+1
1+1: For the TRIO AC-UPS, two energy storage systems of the same capacity are always required.
The data is based on an ambient temperature of +20°C.

70 PHOENIX CONTACT
~ + –

Power supply UPS module Energy storage


systems

UNO UPS STEP UPS

~ + –

Input 23 V DC ... 30 V DC 22.5 V DC ... 29.5 V DC 10 V DC ... 16.5 V DC
W x H x D in mm 110 x 90 x 90 108 x 90 x 61 108 x 90 x 61

24 V/60 W 24 DC / 24 DC / 3 A 12 DC / 12 DC / 4 A


Type UNO-UPS/24DC/24DC/60W STEP-UPS/24DC/24DC/3/46WH STEP-UPS/12C/12DC/4/46WH
Order No. 2905907 1081430 1082548
Energy storage systems Lead AGM technology Lithium-ion technology Lithium-ion technology

Buffer times for UNO UPS and STEP UPS


Example: 2.5 A is to be buffered for Buffer time
Load Seconds Minutes Hours
10 minutes. current 0.2 0.4 1 2 8 16 30 1 2 3 5 6 7 8 9 10 15 20 25 30 40 45 50 1 1.5 2 3
0.5 A
1A
1.5 A
2A
STEP-UPS/24DC/24DC/3A 2.5 A
3A
4A
The data is based on an ambient temperature of +20°C.

PHOENIX CONTACT 71
Selection guide for UPS modules with integrated power supply

Small and flexible MINI UPS TRIO UPS


The MINI UPS and TRIO UPS combine a The MINI UPS, with its comprehensive Supply DC loads reliably and save space with
power supply and electronic switch-over signaling functions, is always used in the new uninterruptible TRIO power supplies.
unit in the same housing. They ensure the applications where space-saving solutions An input grid is no longer necessary for
operation of DC loads in the event of mains are needed. The energy storage system with startup. Connected industrial PCs can be shut
faults. lead AGM technology enables buffer times at down easily via the integrated USB interface.
Just one energy storage system is required to nominal load of up to 40 minutes at output
complete the UPS system. voltages of 24 V DC or 12 V DC.

Web code: #1991

~ + –

Power supply UPS module Energy storage


systems

Energy storage systems for MINI


MINI UPS 1~
UPS

~ + – ~ + –

85 V AC ... 264 V AC, 85 V AC ... 264 V AC, Energy storage


Input Lead AGM technology Lead AGM technology
100 V DC ... 350 V DC 100 V DC ... 350 V DC systems
W x H x D in mm 67.5 x 99 x 107 67.5 x 99 x 107 W x H x D in mm 67.5 x 99 x 107 52 x 130 x 110

24 DC / 2 A 12 DC / 4 A 24 DC / 0.8 Ah 24 DC / 1.3 Ah


Type MINI-DC-UPS/24DC/2 MINI-DC-UPS/12DC/4 Type MINI-BAT/24DC/0.8AH MINI-BAT/24DC/1.3AH
Order No. 2866640 2866598 Order No. 2866666 2866417
12 DC / 1.6 Ah 12 DC / 2.6 Ah
Type MINI-BAT/12DC/1.6AH MINI-BAT/12DC/2.6AH
Order No. 2866572 2x 2866569 2x

Buffer times for MINI DC UPS


Select your MINI BAT for your MINI UPS Minutes Hours
here. Load current 2 3 5 6 7 8 9 10 20 30 40 45 50 1 2
Example: 1 A is to be buffered for 0.5 A
1A
20 minutes. 1.5 A
2A
The data is based on an ambient temperature of +20°C.
MINI-DC-UPS/24DC/2 and
MINI-BAT/24DC/0.8AH

72 PHOENIX CONTACT
TRIO DC UPS 1~ TRIO DC UPS 3~ Accessories

~ + –

100 V AC ... 240 V AC, 100 V AC ... 240 V AC, 3 x 400 V AC ... 500 V AC For communication between
Input
110 V DC ... 250 V DC 110 V DC ... 250 V DC 2 x 400 V AC ... 500 V AC the UPS module and the
UPS-CONF, length 3 m
W x H x D in mm 60 x 130 x 115 68 x 130 x 160 88 x 130 x 160

24 DC / 5 A 24 DC / 10 A 24 DC / 20 A USB data cable


MINI-SCREW-
Type TRIO-UPS-2G/1AC/24DC/5 TRIO-UPS-2G/1AC/24DC/10 TRIO-UPS-2G/3AC/24DC/20
USB-DATACABLE
Order No. 2907160 2907161 2906367 2908217

UPS-BAT/VRLA

+ –

W x H x D in mm 85 x 191 x 110 135 x 202 x 110 202 x 202 x 110 152 x 167 x 181 330 x 221 x 197

3.4 Ah 7.2 Ah 12 Ah 20 Ah New 38 Ah


UPS-BAT/VRLA/ UPS-BAT/VRLA/ UPS-BAT/VRLA/ UPS-BAT/VRLA/ UPS-BAT/VRLA/
Type
24DC/3.4AH 24DC/7.2AH 24DC/12AH 24DC/20AH 24DC/38AH
Order No. 2320306 2320319 2320322 1109004 2320335

Buffer times for TRIO DC UPS with VRLA energy storage system
Select your energy storage system for your Load Seconds Minutes Hours
TRIO DC UPS here. current 10 15 30 1 2 3 5 6 7 8 9 10 20 30 40 45 50 1 2 3 5 8 10 15 20
1A
Example: 10 A is to be buffered for
2A 1+1 1+1
10 minutes. 3A 1+1 1+1
5A 1+1 1+1
7A 1+1 1+1
10 A 1+1 1+1
15 A 1+1 1+1
TRIO-UPS-2G/1AC/24DC/10 and 20 A 1+1
UPS-BAT/VRLA/24DC/3.4AH The data is based on an ambient temperature of +20°C.

PHOENIX CONTACT 73
Product overview Accessories

Mounting on level surfaces

Adapter UWA 182/52 Adapter UWA 130


Order No. 2938235 2901664
Information For: For:
QUINT-PS QUINT-PS
QUINT4-PS QUINT4-PS
QUINT-UPS QUINT4-UPS
QUINT4-UPS/24DC/24DC/... QUINT4-CHARGER
QUINT4-UPS/1AC/1AC/500VA/USB QUINT4-CAP
QUINT4-CHARGER QUINT4-BUFFER
QUINT4-CAP QUINT4-INV
QUINT4-BUFFER TRIO-UPS-2G
QUINT4-INV
TRIO-PS from 10 A
TRIO-UPS-2G/1AC/24DC/...

Programming adapters Cooling fans

Fan for QUINT,


TWN4 MIFARE NFC USB ADAPTER
QUINT-PS/FAN/4
Order No. 2909681 2320076
Description • Programming adapter for near field communication (NFC) • In the standard power supply mounting position, the temperature
• With USB interface range increases by 10 K (max. ambient temperature of +70°C)
• For configuring NFC-capable QUINT POWER power supplies • When the mounting position is rotated, position-dependent
wirelessly derating no longer applies
• Tool-free mounting

74 PHOENIX CONTACT
Product overview Accessories for uninterruptible power supplies

Accessories for QUINT UPS

Programming adapters RS-232 data cable Open End data cable MINI DIN data cable
Type IFS-BT-PROG-ADAPTER IFS-RS232-DATACABLE IFS-OPEN-END-DATACABLE IFS-MINI-DIN-DATACABLE
Order No. 2905872 2320490 2320450 2320487
Description • Bluetooth programming adapter • Modbus communication with • Open cable for flexible • Direct communication with the
for wireless communication RS-232 interface communication Inline controller (ILC) from the
between the UPS module and • COM server from • Length: 2 m Phoenix Contact Inline system
the UPS-CONF Phoenix Contact for Ethernet (100 series)
communication • Length: 2 m
• Address higher-level controllers
such as Inline controllers (ILCs)
or Remote Field Controllers
(RFCs) directly
• Use the Phoenix Contact Inline
controller as a gateway and
access other communication
protocols
• Length: 2 m

Accessories for QUINT UPS

FL COMSERVER
Software USB data cable Memory block Memory block
UNI 232/422/485
Type UPS-CONF IFS-USB-DATACABLE IFS-CONFSTICK IFS-CONFSTICK-L
Order No. 2320403 2320500 2986122 2901103 2313452
Description • Available free-of-charge • For communication • For saving and • For saving and • Integration of serial RS-
on the Phoenix Contact between the UPS transferring configured transferring configured 232, RS-422, and
website under module and the UPS- values to other values to other RS-485 interfaces
“Downloads” on the CONF QUINT UPS modules or QUINT UPS modules or • For machine and system
access via Ethernet
QUINT-UPS/... product • Length: 3 m for use as a service stick for use as a service stick
network
pages • With lock • Without lock
• Can remain in the UPS

PHOENIX CONTACT 75
Accessories for uninterruptible power supplies

Energy storage system mounting

BATTERY BATTERY BATTERY


MOUNTING KIT MOUNTING CASE MOUNTING CASE
Order No. 2320788 1134645 2320458
Information For: For: For:
UPS-BAT/VRLA/24DC/20AH UPS-BAT/VRLA/24DC/20AH UPS-BAT/LI-ION/24DC/924WH
UPS-BAT/VRLA/24DC/38AH UPS-BAT/VRLA-WTR/24DC/13AH UPS-BAT/VRLA-WTR/24DC/26AH
UPS-BAT/VRLA-WTR/24DC/13AH UPS-BAT/VRLA/24DC/38AH
UPS-BAT/VRLA-WTR/24DC/26AH
UPS-BAT/LI-ION/24DC/924WH

Fuses for AC UPS

FUSE 40 A / 32 V ATOF FUSE 10 A / 400 V GRL


Order No. 2908357 2908358
Information For: For:
TRIO-UPS-2G/1AC/1AC/230V/750VA TRIO-UPS-2G/1AC/1AC/230V/750VA
TRIO-UPS-2G/1AC/1AC/120V/750VA TRIO-UPS-2G/1AC/1AC/120V/750VA
QUINT4-UPS/1AC/1AC/500VA/USB

Fuses for UPS-BAT energy storage system

FUSE 15 A / 32 V FK1 FUSE 25 A / 32 V ATOF FUSE 30 A / 32 V ATOF
Order No. 2908360 2908366 2908365
Information For: For: For:
UPS-BAT/VRLA/24DC/1.3AH UPS-BAT/VRLA/24DC/3.4AH UPS-BAT/LI-ION/24DC/120WH
UPS-BAT/VRLA/24DC/7.2AH
UPS-BAT/VRLA/24DC/12AH
UPS-BAT/VRLA/24DC/38AH
UPS-BAT/VRLA-WTR/24DC/13AH
UPS-BAT/VRLA-WTR/24DC/26AH
UPS-BAT/LI-ION/24DC/924WH

76 PHOENIX CONTACT
Accessories for uninterruptible power supplies

MINI-BAT and UNO-UPS fuses for energy storage systems

FUSE 5 A / 32 V FK1 FUSE 15 A / 32 V FKS FUSE 10 A / 32 V FK1 FUSE 25 A / 32 V FKS
Order No. 1104162 2908361 2908364 2908363
Information For: For: For: For:
UNO-UPS/24DC/24DC/60W MINI-BAT/24DC/1.3AH MINI-BAT/12DC/1.6AH MINI-BAT/12DC/2.6AH

Replacement
Replacement battery
Replacement batteries for UPS-BAT/VRLA batteries for UPS-
for UPS-BAT/LI-ION
BAT/VRLA/WTR

BAT-KIT 2X12V/1.3AH BAT-KIT 2X12V/38AH BAT-KIT-WTR 2X12V/13AH BAT-KIT 2V/120AH


Order No. 2908665 2908237 2908368 2908370
BAT-KIT 2X12V/3.4AH BAT-KIT-WTR 2X12V/26AH
Order No. 2908233 2908369
BAT-KIT 2X12V/7.2AH
Order No. 2908234
BAT-KIT 2X12V/12AH
Order No. 2908235

PHOENIX CONTACT 77
Approvals for QUINT POWER
UL CSA Ship EX

Medical stand. IEC 60601, 2 x MOOP


UL Listed ANSI/ISA-12.12.01 Class I,

ABS – American Bureau of Shipping


UL/C-UL Recognized UL 60950

Division 2, Groups A, B, C, D

SEMI F47-0706 Compliance


NK – Nippon Kaiji Kyokai
CSA 22.2 No 60950-1-07
UL/C-UL Listed UL 508

CSA 22.2 No 107.1-01


UL 1310 NEC Class 2
UL/C-UL listed 61010

LR – Lloyd’s Register

EN 50121-4, -5, -3-2


BV – Bureau Veritas

Installation altitude
UL Listed UL 508

Startup at -40°C
DNV GL Group

ATEX/IECEx

DeviceNet™

CB Scheme
EAC-Ex
RINA

EAC
CE
QUINT POWER power supplies with SFB Technology
QUINT4-PS/1AC/24DC/5 2904600 • • • • • • • • • • • • • • c
QUINT4-PS/1AC/24DC/10 2904601 • • • • • • • • • • • • • • • c
QUINT4-PS/1AC/24DC/20 2904602 • • • • • • • • • • • • • • • c
QUINT4-PS/1AC/24DC/20/+ 2904617 • • • • • • • • • • • • • • c
QUINT4-PS/1AC/24DC/40 2904603 • • • • • • * • • • • • c
QUINT-PS/1AC/24DC/3.5 2866747 • • • • • • • • • • • • • • • • • c
QUINT4-PS/1AC/12DC/15 2904608 • • • • • • • * * * • • • • • c
QUINT-PS/1AC/12DC/20 2866721 • • • • • • • • • • • • d
QUINT4-PS/1AC/48DC/5 2904610 • • • • • • • * * * • • • • • c
QUINT4-PS/1AC/48DC/10 2904611 • • • • • • • • • • • • • • • c
QUINT-PS/1AC/48DC/20 2866695 • • • • • • • • • • • d
QUINT4-PS/3AC/24DC/5 2904620 • • • • • • • • • • • • • • • c
QUINT4-PS/3AC/24DC/10 2904621 • • • • • • • • • • • • • • • c
QUINT4-PS/3AC/24DC/20 2904622 • • • • • • • • • • • • • • • c
QUINT4-PS/3AC/24DC/40 2904623 • • • • • • * • • • • • c
QUINT-PS/3AC/48DC/20 2320827 • • • • • • • • • • b
QUINT4-PS/1AC/24DC/10/CO 2904625 • • • • • • • • • • • • • • • c
QUINT4-PS/1AC/48DC/10/CO 2904626 • • • • • • • • • • • • • • • c
QUINT-PS/1AC/24DC/5/CO 2320908 • • • • • • • • • • • • • • • • d
QUINT-PS/1AC/24DC/10/CO 2320911 • • • • • • • • • • • • • • • • • • • • • c
QUINT-PS/1AC/24DC/20/CO 2320898 • • • • • • • • • • • • • • • • d
QUINT-PS/3AC/24DC/20/CO 2320924 • • • • • • • • • • • • c

QUINT POWER power supplies <100 W


QUINT4-PS 1AC/24DC/1.3/PT 2909575 • • • • • • • • • • c
QUINT4-PS 1AC/24DC/1.3/SC 2904597 • • • • • • • • • • c
QUINT4-PS 1AC/24DC/2.5/PT 2909576 • • • • • • • • • • c
QUINT4-PS 1AC/24DC/2.5/SC 2904598 • • • • • • • • • • c
QUINT4-PS 1AC/24DC/3.8/PT 2909577 • • • • • • • • • • c
QUINT4-PS 1AC/24DC/3.8/SC 2904599 • • • • • • • • • • c
QUINT4-PS 1AC/5DC/5/PT 2904595 • • • • * • • • • • c
QUINT4-PS 1AC/12DC/2.5/PT 2904605 • • • • • • • • • c
QUINT4-PS 1AC/12DC/7.5/PT 2904607 • • • • • • • • • c

* Approval in preparation
a) max. 3000 m b) max. 4000 m c) max. 5000 m d) max. 6000 m e) max. 2000 m
All products receive further approvals on a continual basis.
For up-to-date information, please refer to the Phoenix Contact website under “Downloads” on the respective product pages.

78 PHOENIX CONTACT
Approvals for TRIO POWER
UL CSA Ship EX

Medical stand. IEC 60601, 2 x MOOP


UL Listed ANSI/ISA-12.12.01 Class I,

ABS – American Bureau of Shipping


UL/C-UL Recognized UL 60950

Division 2, Groups A, B, C, D

SEMI F47-0706 Compliance

Railway standard EN 50155


NK – Nippon Kaiji Kyokai
UL/C-UL Listed UL 508

CSA 22.2 No 107.1-01


UL 1310 NEC Class 2
UL/C-UL listed 61010

cCSAus 61010-2-201

LR – Lloyd’s Register
BV – Bureau Veritas

Installation altitude
UL Listed UL 508

Startup at -40°C
DNV GL Group

DeviceNet™

CB Scheme
IECEx
ATEX
RINA

EAC
CE

TRIO POWER power supplies


TRIO-PS-2G/1AC/24DC/3/C2LPS 2903147 • • • • • • •* • • c
TRIO-PS-2G/1AC/24DC/5 2903148 • • • • • •* • • c
TRIO-PS-2G/1AC/24DC/5/B+D 2903144 • • • • • • c
TRIO-PS-2G/1AC/24DC/10 2903149 • • • • • •* • • • c
TRIO-PS-2G/1AC/24DC/10/B+D 2903145 • • • • • • c
TRIO-PS-2G/1AC/24DC/20 2903151 • • • • • •* • • • b
TRIO-PS-2G/1AC/12DC/5/C2LPS 2903157 • • • • • • • c
TRIO-PS-2G/1AC/12DC/10 2903158 • • • • • • c
TRIO-PS-2G/1AC/48DC/5 2903159 • • • • • • c
TRIO-PS-2G/1AC/48DC/10 2903160 • • • • • • c
TRIO-PS-2G/3AC/24DC/5 2903153 • • • • • • • c
TRIO-PS-2G/3AC/24DC/10 2903154 • • • • • • • • c
TRIO-PS-2G/3AC/24DC/20 2903155 • • • • • • • • c
TRIO-PS-2G/3AC/24DC/40 2903156 • • • • • • b
TRIO-PS-2G/3AC/72DC/14 1076188 • • b

TRIO POWER IP67 power supplies


TRIO-PS-IP67/1AC/24DC/20 1039830 • • • • • b
TRIO-PS-IP67/3AC/24DC/20 1039829 • • • • • c

TRIO CROSS POWER power supplies


EM-CPS-PS/3AC/24DC/5 1064922 • • • • c
EM-CPS-PS/3AC/24DC/20/8C/IOL 1067898 • • • • c

PHOENIX CONTACT 79
Approvals for UNO POWER
UL CSA Ship EX

SEMI F47-0706 Compliance Certificate

Railway standard EN 50155, 50121-4


UL Listed ANSI/ISA-12.12.01 Class I,

ABS – American Bureau of Shipping

IEC 60335-1 household standard

Medical standard IEC 60601, 2 x


UL/C-UL Recognized UL 60950

Division 2, Groups A, B, C, D

NK – Nippon Kaiji Kyokai


CSA 22.2 No 60950-1-07
UL/C-UL Listed UL 508

CSA 22.2 No 107.1-01


UL 1310 NEC Class 2
UL/C-UL listed 61010

LR – Lloyd’s Register
BV – Bureau Veritas

Installation altitude
Startup at -40°C
DNV GL Group

DeviceNet™

CB Scheme
PQ Star

MOOP
ATEX
RINA

EAC
CE

UNO POWER power supplies


UNO-PS/1AC/24DC/30W 2902991 • • • • • • • a
UNO-PS/1AC/24DC/60W 2902992 • • • • • • • • d
UNO-PS/1AC/24DC/90W/C2LPS 2902994 • • • • • • • a
UNO-PS/1AC/24DC/100W 2902993 • • • • • • a
UNO-PS/1AC/24DC/100W/H 1088851 • • • • • • a
UNO-PS/1AC/24DC/150W 2904376 • • • • • • c
UNO-PS/1AC/24DC/240W 2904372 • • • • • • a
UNO2-PS/1AC/24DC/480W 2910105 • • • • a
UNO-PS/1AC/5DC/25W 2904374 • • • • • • • b
UNO-PS/1AC/5DC/40W 2904375 • • • • • • a
UNO-PS/1AC/12DC/30W 2902998 • • • • • • a
UNO-PS/1AC/12DC/55W 2902999 • • • • • • d
UNO-PS/1AC/12DC/55W/H 1088850 • • • • • • d
UNO-PS/1AC/12DC/100W 2902997 • • • • • • c
UNO-PS/1AC/15DC/30W 2903000 • • • • • • • a
UNO-PS/1AC/15DC/55W 2903001 • • • • • • d
UNO-PS/1AC/15DC/100W 2903002 • • • • • • d
UNO-PS/1AC/48DC/60W 2902995 • • • • • • • d
UNO-PS/1AC/48DC/100W 2902996 • • • • • • c
UNO-PS/2AC/24DC/90W/C2LPS 2904371 • • • • • • • b

* Approval in preparation
a) max. 3000 m b) max. 4000 m c) max. 5000 m d) max. 6000 m e) max. 2000 m
All products receive further approvals on a continual basis.
For up-to-date information, please refer to the Phoenix Contact website under “Downloads” on the respective product pages.

80 PHOENIX CONTACT
Approvals for STEP POWER
UL CSA Ship EX

SEMI F47-0706 Compliance Certificate

Railway standard EN 50155, 50121-4


UL Listed ANSI/ISA-12.12.01 Class I,

ABS – American Bureau of Shipping

IEC 60335-1 household standard

Medical standard IEC 60601, 2 x


UL/C-UL Recognized UL 60950

Division 2, Groups A, B, C, D

NK – Nippon Kaiji Kyokai


CSA 22.2 No 60950-1-07
UL/C-UL Listed UL 508

CSA 22.2 No 107.1-01


UL 1310 NEC Class 2
UL/C-UL listed 61010

LR – Lloyd’s Register
BV – Bureau Veritas

Installation altitude
Startup at -40°C
DNV GL Group

DeviceNet™

CB Scheme
PQ Star

MOOP
ATEX
RINA

EAC
CE

STEP POWER power supplies


STEP3-PS/1AC/24DC/0.63/PT 1088495 • • • • • • • b
STEP3-PS/1AC/24DC/1.3/PT 1088494 • • • • • • • b
STEP3-PS/1AC/24DC/2.5/PT 1088491 • • • • • • • b
STEP3-PS/1AC/24DC/4/PT 1040066 • • • • • • b
STEP3-PS/1AC/24DC/5/PT 1088478 • • • • • • b
STEP-PS/1AC/24DC/0.5 2868596 • • • • • • • • b
STEP-PS/1AC/24DC/0.75FL 2868622 • • • • • • • • • • • • c
STEP-PS/1AC/24DC/0.75 2868635 • • • • • • • • • • • • • • • c
STEP-PS/1AC/24DC/1.75 2868648 • • • • • • • • • • • c
STEP-PS/1AC/24DC/2.5 2868651 • • • • • • • • • • • • • • a
STEP-PS/1AC/24DC/3.8/C2LPS 2868677 • • • • • • • • • • d
STEP-PS/1AC/24DC/4.2 2868664 • • • • • • • • • • d
STEP-PS/1AC/5DC/2 2320513 • • • • • • b
STEP-PS/1AC/5DC/6.5 2868541 • • • • • • • • • • d
STEP-PS/1AC/12DC/1 2868538 • • • • • • • • b
STEP-PS/1AC/12DC/1.5FL 2868554 • • • • • • • • • • • • c
STEP-PS/1AC/12DC/1.5 2868567 • • • • • • • • • • • • c
STEP-PS/1AC/12DC/3 2868570 • • • • • • • • • • • c
STEP-PS/1AC/12DC/5 2868583 • • • • • • • • • • d
STEP-PS/1AC/15DC/4 2868619 • • • • • • • • • • c
STEP-PS/1AC/48DC/2 2868680 • • • • • • • • • • d
STEP-PS/48AC/24DC/0.5 2868716 • • • • • • • b
STEP-PS/277AC/24DC/3.5 2904945 • • • • • • a

PHOENIX CONTACT 81
Approvals for DC/DC converters
UL CSA Ship EX

UL Listed ANSI/ISA-12.12.01 Class I,

ABS – American Bureau of Shipping


UL/C-UL Recognized UL 62109-1

Railway standard EN 50155:2007


UL/C-UL Recognized UL 60950

Division 2, Groups A, B, C, D

Railway standard EN 50121-4


NK – Nippon Kaiji Kyokai
CSA 22.2 No 60950-1-07
UL/C-UL Listed UL 508

CSA 22.2 No 107.1-01


UL 1310 NEC Class 2
UL/C-UL listed 61010

LR – Lloyd’s Register
BV – Bureau Veritas

Installation altitude
Startup at -40°C
DNV GL Group

EN 50121-3-2
ATEX/IECEx

CB Scheme
EAC-Ex
RMRS
RINA

EAC
CE
DC/DC converters
QUINT4-PS/24DC/24DC/5/PT 2910119 • • • • * * * * * • • • • • • c
QUINT4-PS/24DC/24DC/5/SC 1046800 • • • • * * * * * • • • • • • c
QUINT4-PS/24DC/24DC/10/PT 2910120 • • • • * * * * * • • • • • • c
QUINT4-PS/24DC/24DC/10/SC 1046803 • • • • * * * * * • • • • • • c
QUINT4-PS/24DC/24DC/20/PT 2910121 • * * * * * * * • • • • • c
QUINT4-PS/24DC/24DC/20/SC 1046805 • * * * * * * * • • • • • c
QUINT4-PS/24DC/24DC/20/SC/+ 1046881 • * * * * * * * • • • • • c
QUINT4-PS/24DC/12DC/8/PT 2910122 • • • • * * * * * • • • • • • c
QUINT4-PS/24DC/48DC/5/PT 2910123 • * * * * * * *
QUINT4-PS/48DC/24DC/5/PT 2910125 • • • • * * * * * • • • • • • c
QUINT4-PS/48DC/48DC/5/PT 2910128 • * * * * * * *
QUINT-PS/12DC/24DC/5 2320131 • • • • • • • • • • • • • • • d
QUINT-PS/12DC/12DC/8 2905007 • • • • • • • • • d
QUINT-PS/60-72DC/24DC/10 2905009 • • • • • • • • • d
QUINT-PS/96-110DC/24DC/10 2905010 • • • • • • • • • d
QUINT-PS/24DC/24DC/5/CO 2320542 • • • • • • • • • • • • • • • • • • d
QUINT-PS/24DC/24DC/10/CO 2320555 • • • • • • • • • • • • • • • • • • d
QUINT-PS/24DC/24DC/20/CO 2320568 • • • • • • • • • • • • • • • • • d
QUINT-PS/60-72DC/24DC/10/CO 2905011 • • • • • • • • • • d
QUINT-PS/96-110DC/24DC/10/CO 2905012 • • • • • • • • • • d
UNO-PS/350-900DC/24DC/60W 2906300 • • • • c
TRIO-PS-2G/1500DC/24DC/8 1075240 • • • • • b
MINI-PS-12-24DC/24DC/1 2866284 • • • • • • d
MINI-PS-12-24DC/5-15DC/2 2320018 • • • • • • • d
MINI-PS-12-24DC/48DC/0.7 2320021 • • • • • • • d
MINI-PS-48-60DC/24DC/1 2866271 • • • • • d
MINI-PS/10-42AC/15-60DC/3 2320199 • • • • • d

* Approval in preparation
a) max. 3000 m b) max. 4000 m c) max. 5000 m d) max. 6000 m e) max. 2000 m
All products receive further approvals on a continual basis.
For up-to-date information, please refer to the Phoenix Contact website under “Downloads” on the respective product pages.

82 PHOENIX CONTACT
Inverters

Redundancy modules

STEP-DIODE/5-24DC/2x5/1x10
QUINT4-ORING/12-24DC/1x40

QUINT-ORING/24DC/2x40/1x80
QUINT-ORING/24DC/2x20/1x40
QUINT-ORING/24DC/2x10/1x20

UNO-DIODE/5-24DC/2x10/1x20
QUINT4-ORING/12-24DC/1x40/+

QUINT4-DIODE/48DC/2x20/1X40

TRIO2-DIODE/12-24DC/2x20/1x40
TRIO2-DIODE/12-24DC/2x10/1x20
QUINT4-INV/24DC/1AC/600VA/USB

QUINT4-S-ORING/12-24DC/1x40/VP

QUINT4-DIODE/12-24DC/2x20/1X40

2868606
2905489
2907379
2907380
2907720
2907719
2902879
2320186
2320173
1043418
2907753
2907752
1067325














CE CE
UL Listed UL 508 * ANSI/UL 61010-1

UL
UL













*
UL/C-UL Listed UL 508 ANSI/UL 61010-2-201













UL/C-UL Recognized UL 60950 UL/C-UL Recognized UL 60950
UL 1778 UL 1778
UL Listed ANSI/ISA-12.12.01 Class I,









UL 121201 Class I and II, Div 2 and
*

Division 2, Groups A, B, C, D Class III, Div 1 and 2 Hazardous


UL 1310 NEC Class 2 Locations
Approvals for inverters and redundancy modules

CSA 22.2 No 107.1-01 CAN/CSA-C22.2 No. 61010-1


CSA
CSA

CSA 22.2 No 60950-1-07 CAN/CSA-C22.2 No. 61010-2-201








DNV GL Group DNV GL Group
Ship
Ship




ABS – American Bureau of Shipping ABS – American Bureau of Shipping




BV – Bureau Veritas BV – Bureau Veritas




LR – Lloyd’s Register LR – Lloyd’s Register




NK – Nippon Kaiji Kyokai NK – Nippon Kaiji Kyokai




RINA RINA







ATEX/IECEx ATEX
EX
EX







EAC-Ex IECEx
DeviceNet™ DeviceNet™
SEMI F47-0706 Compliance Certificate SEMI F47-0706 Compliance Certificate
PQ Star PQ Star









*

CB Scheme CB Scheme in acc. with IEC 61010-1


*

Medical standard IEC 60601 CB Scheme in acc. w. IEC 61010-2-201












EAC EAC

PHOENIX CONTACT











Startup at -40°C Startup at -40°C


c
c
c

e
e
e
e
e
e
e
e
e

Installation altitude Installation altitude

83
Approvals for uninterruptible power supplies
UL CSA Ship EX

UL Listed ANSI/ISA-12.12.01 Class I,

ABS – American Bureau of Shipping


UL/C-UL Recognized UL 60950

Division 2, Groups A, B, C, D

Medical standard IEC 60601


SEMI F47-0706 Compliance
NK – Nippon Kaiji Kyokai
CSA 22.2 No 60950-1-07
UL/C-UL Listed UL 508

CSA 22.2 No 107.1-01


UL 1310 NEC Class 2
UL/C-UL listed 61010

LR – Lloyd’s Register
BV – Bureau Veritas

Installation altitude
UL Listed UL 508

Startup at -40°C
DNV GL Group

CB Scheme
UL 1778

ATEX
RINA

EAC
CE
Uninterruptible power supplies
QUINT4-UPS/24DC/24DC/5/PN 2906993 • • • * * * * * * • • • b
QUINT4-UPS/24DC/24DC/10/PN 2907068 • • • * * * * * * • • • b
QUINT4-UPS/24DC/24DC/20/PN 2907073 • • • * * * * * * • • • b
QUINT4-UPS/24DC/24DC/40/PN 2907079 • • • * * * * * * • • • b
QUINT4-UPS/24DC/24DC/5/EIP 2906994 • • • * * * * * * • • • b
QUINT4-UPS/24DC/24DC/10/EIP 2907069 • • • * * * * * * • • • b
QUINT4-UPS/24DC/24DC/20/EIP 2907074 • • • * * * * * * • • • b
QUINT4-UPS/24DC/24DC/40/EIP 2907080 • • • * * * * * * • • • b
QUINT4-UPS/24DC/24DC/5/EC 2906996 • • • * * * * * * • • • b
QUINT4-UPS/24DC/24DC/10/EC 2907070 • • • * * * * * * • • • b
QUINT4-UPS/24DC/24DC/20/EC 2907076 • • • * * * * * * • • • b
QUINT4-UPS/24DC/24DC/40/EC 2907081 • • • * * * * * * • • • b
QUINT4-UPS/24DC/24DC/5/USB 2906991 • • • * * * * * * • • • b
QUINT4-UPS/24DC/24DC/10/USB 2907067 • • • * * * * * * • • • b
QUINT4-UPS/24DC/24DC/20/USB 2907072 • • • * * * * * * • • • b
QUINT4-UPS/24DC/24DC/40/USB 2907078 • • • * * * * * * • • • b
QUINT4-UPS/24DC/24DC/5 2906990 • • • * * * * * * • • • b
QUINT4-UPS/24DC/24DC/10 2907066 • • • * * * * * * • • • b
QUINT4-UPS/24DC/24DC/20 2907071 • • • * * * * * * • • • b
QUINT4-UPS/24DC/24DC/40 2907077 • • • * * * * * * • • • b
QUINT4-CHARGER/1AC/24DC/10 2907990 • • •
QUINT-UPS/24DC/12DC/5/24DC/10 2320461 • • • • e
QUINT4-UPS/1AC/1AC/500VA/USB 1067327 • • * * * a
QUINT4-UPS/1AC/1AC/1KVA 2320283 • • • • • • a
TRIO-UPS-2G/1AC/1AC/230V/750VA 2905909 • • • • a
TRIO-UPS-2G/1AC/1AC/120V/750VA 2905908 • • • • a
QUINT-UPS/24DC/24DC/5/1.3AH 2320254 • • • • • d
QUINT-UPS/24DC/24DC/10/3.4AH 2320267 • • • • • d
QUINT4-BUFFER/24DC/24DC/20 2907913 • • • • • • • • b
QUINT4-BUFFER/24DC/24DC/40 2909283 • • • • • • • • b
QUINT4-CAP/24DC/3.8/1KJ/PT 2320526 • • • • •
QUINT4-CAP/24DC/5/4KJ 2320539 • • • • • • • • b
QUINT4-CAP/24DC/10/8KJ 2320571 • • • • • • • • b
UNO-UPS/24DC/24DC/60W 2905907 • • • • e
STEP-UPS/24DC/24DC/3/46WH 1081430 • • • • • e
STEP-UPS/12DC/12DC/4/46WH 1082548 • • • • • e
* Approval in preparation
a) max. 3000 m b) max. 4000 m c) max. 5000 m d) max. 6000 m e) max. 2000 m
All products receive further approvals on a continual basis.
For up-to-date information, please refer to the Phoenix Contact website under “Downloads” on the respective product pages.

84 PHOENIX CONTACT
Approvals for energy storage systems
UL CSA Ship EX

UL Listed ANSI/ISA-12.12.01 Class I,

ABS – American Bureau of Shipping


UL/C-UL Recognized UL 60950

Division 2, Groups A, B, C, D

Medical standard IEC 60601


SEMI F47-0706 Compliance
NK – Nippon Kaiji Kyokai
CSA 22.2 No 60950-1-07
UL/C-UL Listed UL 508

CSA 22.2 No 107.1-01


UL 1310 NEC Class 2
UL/C-UL listed 61010

LR – Lloyd’s Register
BV – Bureau Veritas

Installation altitude
UL Listed UL 508

Startup at -40°C
DNV GL Group

CB Scheme
UL 1778

ATEX
RINA

EAC
CE
Uninterruptible power supplies
TRIO-UPS-2G/1AC/24DC/5 2907160 • • • * • • d
TRIO-UPS-2G/1AC/24DC/10 2907161 • • • * • • d
TRIO-UPS-2G/3AC/24DC/20 2906367 • • • * • • d
MINI-DC-UPS/24DC/2 2866640 • • • • • c
MINI-DC-UPS/12DC/4 2866598 • • • • • • d

UL CSA Ship EX

SEMI F47-0706 Compliance Certificate


UL Listed ANSI/ISA-12.12.01 Class I,

ABS – American Bureau of Shipping


UL/C-UL Recognized UL 60950

Division 2, Groups A, B, C, D

Medical standard IEC 60601


NK – Nippon Kaiji Kyokai
CSA 22.2 No 60950-1-07
UL/C-UL Listed UL 508

CSA 22.2 No 107.1-01


UL 1310 NEC Class 2

LR – Lloyd’s Register
BV – Bureau Veritas

Installation altitude
UL Listed UL 508

Startup at -40°C
DNV GL Group

CB Scheme
DeviceNet
UL 1778

PQ Star
IECEx
ATEX
RINA

EAC
CE

Energy storage systems


UPS-BAT/VRLA/24DC/1.3AH 2320296 • • • • • d
UPS-BAT/VRLA/24DC/3.4AH 2320306 • • • • • • • d
UPS-BAT/VRLA/24DC/7.2AH 2320319 • • • • • • • d
UPS-BAT/VRLA/24DC/12AH 2320322 • • • • • • • d
UPS-BAT/VRLA/24DC/20AH 1109004 • • • • * • • d
UPS-BAT/VRLA/24DC/38AH 2320335 • • • • • • • • d
UPS-BAT/VRLA-WTR/24DC/13AH 2320416 • • • • • • • • d
UPS-BAT/VRLA-WTR/24DC/26AH 2320429 • • • • • • • • d
UPS-BAT/LI-ION/24DC/120WH 2320351 • • • • • d
UPS-BAT/LI-ION/24DC/924 WH 2908232 • • • • • d
UPS-CAP/24DC/10A/10KJ 2320377 • • • • • • • • d
UPS-CAP/24DC/20A/20KJ 2320380 • • • • • • • • d
STEP-BAT/LI-ION/18.5DC/46WH 1081355 • • • e
MINI-BAT/24DC/0.8AH 2866666 • • • d
MINI-BAT/24DC/1.3AH 2866417 • • • d
MINI-BAT/12DC/1.6AH 2866572 • • • d
MINI-BAT/12DC/2.6AH 2866569 • • • d

PHOENIX CONTACT 85
COMPLETE line
The comprehensive solution for the control
cabinet
COMPLETE line is a system comprised of technologically leading and coordinated
hardware and software products, consulting services, and system solutions that help
you optimize your processes in control cabinet manufacturing. Engineering, purchasing,
installation, and operation become significantly easier for you.

Web code: #2089

86 PHOENIX CONTACT
Your advantages in detail:

Comprehensive product portfolio Intuitive handling Save time throughout the entire
With COMPLETE line, we offer a complete Thanks to the simple, intuitive handling of engineering process
product portfolio of technologically leading the coordinated hardware components, you The PROJECT complete planning and marking
products. This includes: will save time during installation, startup, software supports the entire process of
• Controllers and I/O modules and maintenance. Push-in connection control cabinet manufacturing. The program
• Power supplies and device circuit breakers technology enables you to wire applications features an intuitive user interface that
• Terminal blocks and distribution blocks quickly – without using tools. The broad, enables the individual planning, automatic
• Relay modules and motor starters technologically leading product portfolio will checking, and direct ordering of terminal
• Signal conditioners always provide you with the right product for strips.
• Safety technology standard or special applications.
• Surge protection
• Heavy-duty connectors

Reduced logistics costs Optimized processes in control The new standard for the control
Reduced variety of parts, thanks to cabinet manufacturing cabinet
standardized marking, bridging, and testing COMPLETE line supports you, from Discover the extensive COMPLETE line
accessories. The COMPLETE line system engineering through to manufacturing, in product portfolio and find out more about
coordinates products, design, and accessories designing your control cabinet production COMPLETE line and your comprehensive
so that you benefit from maximum reusability as efficient as possible. This is how your solutions for the control cabinet.
and thus reduce your logistics costs. customized concept for optimizing your
processes in control cabinet manufacturing is Visit our website:
created. Our terminal strip production helps phoenixcontact.com/completeline
you to flexibly manage order peaks or to
supply your control cabinet production with
fully assembled DIN rails just in time.

PHOENIX CONTACT 87
Iceland Finland

Norway
Sweden Estonia
Latvia
Denmark Lithuania
Ireland Belarus
Netherlands Poland
United Kingdom
Blomberg, Germany Russia
Canada Belgium
Luxembourg Czech Republic
France Austria Slovakia Ukraine Kazakhstan Mongolia
Switzerland Hungary Moldova
Slovenia
Croatia Romania South Korea
USA Bosnia and
Spain Italy Serbia
Herzegovina Kosovo Japan
Montenegro Bulgaria Georgia Uzbekistan
Portugal Armenia China
Macedonia Turkey Azerbaijan
Greece
Tunisia
Lebanon Iraq
Morocco Cyprus Pakistan Taiwan, China
Kuwait Bangladesh
Mexico Israel
Algeria India Myanmar
Dominican Republic Jordan Bahrain
Guatemala Egypt Qatar Sri Lanka
Honduras Saudi Arabia
Nicaragua Thailand Philippines
Trinidad and Tobago UAE
Costa Rica
Panama Venezuela Oman Malaysia Vietnam
Ghana Nigeria
Colombia Cameroon Uganda Singapore
Kenya

Ecuador
Indonesia
Brazil
Peru Tanzania

Zambia
Bolivia Mozambique Mauritius
Namibia Zimbabwe
Botswana
Paraguay
South Africa
Chile

Uruguay

Australia
Argentina
New Zealand

Open communication with customers and partners


worldwide
Phoenix Contact is a global market leader based in Germany. We are known for producing
future-oriented components, systems, and solutions in the fields of electrical engineering,
electronics, and automation. With a global network reaching across more than
100 countries with over 17,600 employees, we maintain close relationships with our
customers, something we believe is essential for our common success.
Our wide variety of innovative products makes it easy for our customers to implement the
latest technology in a variety of applications and industries. We focus on developing the
MNR 52004103/2020-02-15/15
fields of energy, infrastructure, process, and factory automation.

You can find your local partner at

phoenixcontact.com
PS 02-20.000.L3