VQ4000V-OMV0001
Solenoid Valve
PRODUCT NAME
VQ4000/5000
(Pilot Valve V100)
MODEL/ Series
Contents
Mounting ---------------------------------------------------------------------------------------- 6
Piping -------------------------------------------------------------------------------------------- 6
Wiring -------------------------------------------------------------------------------------------- 6
Lubrication -------------------------------------------------------------------------------------- 7
-1-
S
VQ4000V-OMV0001
Safety Instructions
These safety instructions are intended to prevent hazardous situations and/or equipment damage.
These instructions indicate the level of potential hazard with the labels of “Caution,” “Warning” or “Danger.”
They are all important notes for safety and must be followed in addition to International Standards
(ISO/IEC)*1), and other safety regulations.
*1) ISO 4414: Pneumatic fluid power -- General rules relating to systems
ISO 4413: Hydraulic fluid power -- General rules relating to systems
IEC 60204-1: Safety of machinery -- Electrical equipment of machines (Part 1: General requirements)
ISO 10218-1992: Manipulating industrial robots -- Safety
Caution Caution indicates a hazard with a low level of risk which, if not avoided,
could result in minor or moderate injury.
Danger Danger indicates a hazard with a high level of risk which, if not avoided, will
result in death or serious injuty.
Warning
1. The compatibility of the product is the responsibility of the person who designs the equipment or
decides its specifications.
Since the product specified here is used under various operating conditions, its compatibility with specific
equipment must be decided by the person who designs the equipment or decides its specifications based on
necessary analysis and test results.
The expected performance and safety assurance of the equipment will be the responsibility of the person who
has determined its compatibility with the product.
This person should also continuously review all specifications of the product referring to its latest catalog
information, with a view to giving due consideration to any possibility of equipment failure when configuring the
equipment.
2. Only personnel with appropriate training should operate machinery and equipment.
The product specified here may become unsafe if handled incorrectly.
The assembly, operation and maintenance of machines or equipment including our products must be
performed by an operator who is appropriately trained and experienced.
3. Do not service or attempt to remove product and machinery/equipment until safety is confirmed.
1.The inspection and maintenance of machinery/equipment should only be performed after measures to
prevent falling or runaway of the driven objects have been confirmed.
2.When the product is to be removed, confirm that the safety measures as mentioned above are implemented
and the power from any appropriate source is cut, and read and understand the specific product precautions
of all relevant products carefully.
3.Before machinery/equipment is restarted, take measures to prevent unexpected operation and malfunction.
4. Contact SMC beforehand and take special consideration of safety measures if the product is to
be used in any of the following conditions.
1.Conditions and environments outside of the given specifications, or use outdoors or in a place exposed to
direct sunlight.
2.Installation on equipment in conjunction with atomic energy, railways, air navigation, space, shipping,
vehicles, military, medical treatment, combustion and recreation, or equipment in contact with food and
beverages, emergency stop circuits, clutch and brake circuits in press applications, safety equipment or
other applications unsuitable for the standard specifications described in the product catalog.
3.An application which could have negative effects on people, property, or animals requiring special safety
analysis.
4.Use in an interlock circuit, which requires the provision of double interlock for possible failure by using a
mechanical protective function, and periodical checks to confirm proper operation.
-2-
VQ4000V-OMV0001
Safety Instructions
Caution
The product is provided for use in manufacturing industries.
The product herein described is basically provided for peaceful use in manufacturing industries.
If considering using the product in other industries, consult SMC beforehand and exchange specifications
or a contract if necessary.
If anything is unclear, contact your nearest sales branch.
2.For any failure or damage reported within the warranty period which is clearly our responsibility, a
replacement product or necessary parts will be provided.
This limited warranty applies only to our product independently, and not to any other damage
incurred due to the failure of the product.
3.Prior to using SMC products, please read and understand the warranty terms and disclaimers
noted in the specified catalog for the particular products.
Compliance Requirements
1.The use of SMC products with production equipment for the manufacture of weapons of mass
destruction (WMD) or any other weapon is strictly prohibited.
2.The exports of SMC products or technology from one country to another are govemed by the
relevant security laws and regulation of the countries involved in the transaction. Prior to the
shipment of a SMC product to another country, assure that all local rules goveming that export
are known and followed.
-3-
VQ4000V-OMV0001
VQ4000/5000 Series
5-Port Solenoid Valves Precautions 1
Be sure to read this before handling products.
-4-
VQ4000V-OMV0001
VQ4000/5000 Series
5-Port Solenoid Valves Precautions 2
Be sure to read this before handling products.
Design/Selection
3. Solenoid valve drive for AC with a solid state output 5. Surge voltage intrusion
(SSR, TRIAC output, etc.) With non-polar type solenoid valves, at times of sudden
1) Current leakage interruption of the loading power supply, such as emergency
When using a snubber circuit (C-R element) for surge protection shutdown, surge voltage intrusion may be generated from
of the output, a very small amount of electrical current will loading equipment with a large capacity (power consumption),
continue to flow even during the OFF state. and a solenoid valve in a de-energized state may switch over
This results in the valve not returning. In a situation where the (see Figure 1).
tolerance is exceeded, as in the above case, take measures to When installing a breaker circuit for the loading power supply,
install a bleeder resistor. consider using a solenoid valve with polarity (with polarity
2) Minimum allowable load amount (Min. load current) protection diode), or install a surge absorption diode between the
When the consumption current of a valve is less than the loading equipment COM line and the output equipment COM line
output’s minimum allowable load volume or the margin is small, (see Figure 2).
the output may not switch normally. Please contact SMC.
3) Solenoid valve with full wave rectifier circuit
When the solenoid valve built-in full wave rectifier circuit with AC
specifications is used, a return failure of the solenoid valve may
occur depending on the kind of triac output circuit. Carefully
check this point when selecting a SSR or sequencer.
For details, contact the SSR or sequencer manufacturer.
4. Surge voltage suppressor
1) The surge voltage suppressor built into the valve is intended
to protect the output contacts so that the surge generated inside
valve does not adversely affect the output contacts. Therefore, if
an overvoltage or overcurrent is received from an external
peripheral device, the surge voltage protection element inside
the valve is overloaded, causing the element to break. In the
worst case, the breakage causes the electric circuit to enter
short-circuit status. If energizing continues while in this state, a
large current flows. This may cause secondary damage to the
output circuit, external peripheral device, or valve, and may also
cause a fire. So, take appropriate protective measures, such as
the installation of an overcurrent protection circuit in the power
supply or a drive circuit to maintain a sufficient level of safety.
2) If a surge protection circuit contains nonstandard diodes,
such as Zener diodes or varistor, a residual voltage that is in
proportion to the protective circuit and the rated voltage will
remain. Therefore, take into consideration the surge voltage
protection of the controller. In the case of diodes, the residual
voltage is approximately 1 V.
-5-
VQ4000V-OMV0001
VQ4000/5000 Series
5-Port Solenoid Valves Precautions 3
Be sure to read this before handling products.
1. Polarity
There is no polarity.
-6-
VQ4000V-OMV0001
VQ4000/5000 Series
5-Port Solenoid Valves Precautions 4
Be sure to read this before handling products.
3. Drain flushing
If condensation in the drain bowl is not emptied on a regular
2. Applied voltage basis, the bowl will overflow. This may cause the malfunction of
When electric power is connected to a solenoid valve, be careful pneumatic equipment. If the drain bowl is difficult to check and
to apply the proper voltage. Improper voltage may cause remove, the installation of a drain bowl with an auto drain option
malfunction or coil damage. is recommended.
3. Check the connections. For compressed air quality, refer to the SMC Best Pneumatics No. 6
Check if the connections are correct after completing all wiring. catalog.
4. External force applied to the lead wire 4. Use clean air.
If an excessive force is applied to the lead wire, this may cause Do not use compressed air that contains chemicals, synthetic
faulty wiring. Take appropriate measures so that a force of 30 N oils that include organic solvents, salt, corrosive gases, etc., as
or more is not applied to the lead wire. it can cause damage or malfunction.
Lubrication
-7-
VQ4000V-OMV0001
VQ4000/5000 Series
5-Port Solenoid Valves Precautions 5
Be sure to read this before handling products.
3. Low-frequency operation
Operating Environment Valves should be operated at least once every 30 days to
prevent malfunction. (Use caution regarding the air supply.)
4. Manual override
When a manual override is operated, connected equipment
will be actuated.
5. Do not use in a place subject to heavy vibration
Operate only after safety is confirmed.
and/or shock.
5. If the volume of air leakage increases or the valve
6. The valve should not be exposed to prolonged
does not operate normally, do not use the valve.
sunlight. Use a protective cover. Note that the valve
Perform periodic maintenance on the valve to
is not for outdoor use. confirm the operating condition and check for any
7. Remove any sources of excessive heat. air leakage.
8. If it is used in an environment where there is
possible contact with oil, weld spatter, etc., exercise
preventive measures.
9. When the solenoid valve is mounted in a control 1. Drain flushing
panel or it’s energized for a long period of time, make Remove drainage from the air filters regularly.
sure the ambient temperature is within the 2. Lubrication
specifications of the valve. In the case of rubber seals, once lubrication has been started,
it must be continued.
Use class 1 turbine oil (with no additives), VG32. If other
lubricant oil is used, it may cause a malfunction. Please
1. Temperature of ambient environment contact SMC for information on the suggested class 2 turbine
Use the valve within the range of the ambient temperature oil (with additives), VG32.
specification of each valve. In addition, pay attention when using
the valve in environments where the temperature changes 3. Manual override operation
drastically. When switching a double solenoid valve via the manual override
2. Humidity of ambient environment operation, Instantaneous operation may cause the malfunction of
• When using the valve in environments with low humidity, take the cylinder. It is recommended that the manual override be held
measures to prevent static.
until the cylinder reaches the stroke end position.
• If the humidity rises, take measures to prevent the adhesion of
water droplets on the valve.
Maintenance
-8-
VQ4000V-OMV0001
VQ4000/5000 series
Specific Product Precautions 1
Be sure to read this before handling the products.
Continuous Duty Valve Mounting
Manual Override
-9-
VQ4000V-OMV0001
VQ4000/5000 series
Specific Product Precautions 2
Be sure to read this before handling the products.
●Applicable terminal:1.25-3s,1.25Y-3,1.25Y-3N,1.25Y-3.5
Installation and Removal of Light Cover
Lead Wire Connection
● Removal
Remove the mounting screw that holds the pilot valve
using a small screwdriver.
● Installation
After confirming the gasket is correctly placed under the
Installation and Removal of Light Cover valve, securely tighten the bolts with the proper torque
shown in the table below.
Proper tightening torque [N·m]
0.1 to 0.13
Installation/Removal of light cover (VQ4000) Note) The light circuit boards: A side is orange and the B
●Removal side is green. It must be mounted on the pilot valve in
Open the cover by inserting a small flat head accordance with the mounting indicators.
screwdriver into the slot on the side of the pilot assembly
(see drawing below), lift the cover out about 1 mm and
then pull off. If it is pulled off at an angle, the pilot valve
may be damaged or the protective O-ring may be
scratched.
- 10 -
VQ4000V-OMV0001
VQ4000/5000 series
Specific Product Precautions 3
Be sure to read this before handling the products.
Plug Lead Type
Attaching and detaching connectors
● To attach a connector, hold the lever and connector unit Internal Wiring Specifications
between your fingers and insert straight onto the pins of
the solenoid valve so that the lever’s pawl is pushed into
the groove and locks.
● To detach a connector, remove the pawl from the groove
by pushing the lever downward with your thumb, and
pull the connector straight out.
Enclosure IP65
- 11 -
VQ4000V-OMV0001
VQ4000 Series
Construction
Plug-in Unit
Component Parts
Number Description Material Note Component Parts
1 Body Aluminum Number Description Material Note
die-casted 1 Body Aluminum die-casted
2 Spool/Sleeve Stainless steel 2 Spool/Sleeve Aluminum, HNBR
3 Piston Resin 3 Piston Resin
- 12 -
VQ4000V-OMV0001
VQ4000 Series
Construction
- 13 -
VQ4000V-OMV0001
VQ5000 Series
Construction
Plug-in Unit
- 14 -
VQ4000V-OMV0001
VQ5000 Series
Construction
- 15 -
VQ4000V-OMV0001
For valve failure, take following countermeasure
Problem Possible causes Countermeasures
referring to Problem.
1) Sliding failure or sticking of the • Replace the valve.
The valve operate when main valve Foreign matter • Purify the air source.
the manual override coming from the air source is
NO
caught in the main valve, causing
button is pushed? sliding failure or sticking.
2) Decreased pressure • Adjust the pressure within the
Air source pressure is reduced specification range for the valve.
and minimum operating pressure
YES
of the valve was not reached.
1) Non-conformance of electric
system
Indicator LED turns • Incorrect wiring
on when the valve is • Fuse blown out, breakage of lead Check all possible causes and make
wire sure the wiring is correct. Replace the
energized? NO • Incorrect contact at the contact part, if necessary.
and connection
Operation • Sequencer non-conformance
failure • Supply voltage insufficient
1) Drop of supply voltage • Check the supply voltage. Take corrective
Air is not Even if the indicator LED turns on, action if voltage drop is confirmed.
switched. YES the valve may not operate due to
voltage drop.
2) Leakage current Check the residual voltage.
The valve does not switch due to Keep the residual voltage.
the residual voltage when OFF.
DC coil:3% or less of the rated voltage.
AC coil:8% or less of the rated voltage.
3) Failure of the installed pilot
valve
• Pilot valve coil breakage • Replace the pilot valve assembly.
• Foreign matter is caught in the
pilot valve armature. • Clean the air supply
• Swelling of the pilot valve poppet
• Pilot valve coil burnt • Check the voltage, and replace the pilot
(High voltage, difference of the coil valve assembly.
specifications, entry of water) • Protect the valve, especially the coil to
prevent being exposed to water.
1) Leakage current Check the residual voltage.
Response delayed due to the Keep the residual voltage.
Response residual voltage when the valve is DC coil:3% or less of the rated voltage.
failure off. AC coil:8% or less of the rated voltage.
2) Sliding failure or sticking of the • Replace the valve.
Slow main valve. • Clean the air supply
response Foreign matter coming from the air
source is caught in the main valve,
causing sliding failure or sticking.
1-1) Valve mounting screw is loose Make sure that the gasket of the valve
Check the air leakage point mounting surface is not displaced or
deformed before tightening.
Appropriate tightening torque
Air leakage 1. Leakage between the valve and base
• VQ4000 : 0.8 to 1.2N・m
• VQ5000 : 1.0 to 1.8N・m
If gasket is scratched, replace the gasket.
1-2) Gasket is caught Replace the gasket.
- 16 -
VQ4000V-OMV0001
For valve failure, take following countermeasure
Problem Possible causes Countermeasures
referring to Problem.
2. Air leaks from the One-touch fitting. 2-1) Tube is not inserted all the
way into the fitting. Check all possible causes and make sure
2-2) Tube has a gouge the piping is correct. Replace the part, if
2-3) The cut surface of the tube is necessary.
slanted.
2-4) One-touch fitting seal is
Replace One-touch fitting assembly
damaged
3. Air leakage from the exhaust (R) port. 3-1) Internal leakage increased
Air leakage Note) Metal seal type has approximately 250cc of because foreign matter coming • Replace the valve.
leakage per valve set. This is within specification from the air source is caught in
value. (Supply pressure: 0.5 MPa) • Purify the air source.
the main valve.
4. Air leaks from the manifold 4-1) Loose DIN rail clamp screw Hold manifolds tightly for tightening so that
there is no gap between the valves.
Appropriate tightening torque
• VQ4000 : 0.8 to 1.2N・m
• VQ5000 : 1.0 to 1.8N・m
- 17 -
VQ4000V-OMV0001
Revision history
Note: Specifications are subject to change without prior notice and any obligation on the part of the manufacturer.
© 2017 SMC Corporation All Rights Reserved
VQ4000V-OMV0001