This is a quick installation sheet for the Axxon MAP/950 Pro RS422/RS485 2 Port I/O Card for PCI Express
This product is capable of RS422 or RS485 communications up to 10 Mbps speed with a minor clock change.
Compatible with x1, x4, x8, x16 lane expansion slots. The LF686KB is a RoHS & Pb-free compliant product.
RS422/RS485 Contacts are 25kv ESD, thermal and short circuit protected. The transceivers applied in this model are
1/8th load devices and are the part # MAX3079EESD+ (RoHS) by Maxim Semiconductor.
Dipswitches
This adapter card contains 6 banks of dipswitches. A switch positioned to the RIGHT is OFF. Positioned to the LEFT is
ON. The plastic molding on the dipswitch covers contain an ON label with arrow to denote switch orientation.
Configuration Modes
In RS422 mode of operation, the Transmitter and Receiver will be ALWAYS ACTIVE.
For RS422 mode of operation, switch the dipswitch to RS422 position.
In RS485 mode of operation, the Transmitter will be AUTO-GATED (using the DTR line) for multi-drop applications under
the Windows OS. The Receiver is ALWAYS ACTIVE in this mode. See the end of this document to cancel local echo.
For RS485 mode of operation, switch the dipswitch to the RS485 position. You must also select RS485 Active High
Mode under the serial port configuration. This configuration will toggle the DTR line HIGH during a byte transmit and
LOW otherwise.
RS485 communication mode is presently supported under Windows 9x, ME, NT, XP, XP64, 2000, 2003, Vista 32/64.
Additional operating systems support may be available upon request. Please contact Axxon for a WinNT device driver for
RS485 operation.
RS422 communication mode is supported in at least Win 9x, ME, NT, XP, XP64, 2000, 2003, Vista 32/64 and Linux. For
RS422 configuration, as an option you may use the default Microsoft serial driver.
DB9M P1 Connector (close to the PCI edge fingers) = Lower COM Port #.
DB9M P2 Connector (close to the top mounting screw) = Higher COM Port #.
Pin # 1 Ground
Pin # 2 CTS- (optional)
Pin # 3 RTS- (optional)
Pin # 4 RX-
Pin # 5 RTS+ (optional)
Pin # 6 CTS+(optional)
Pin # 7 TX+
Pin # 8 TX-
Pin # 9 RX+
1
3979 Tecumseh Road East, Windsor, Ontario, N8W 1J5 Canada
Voice: 1-519-974-0163 Fax: 1-519-974-0165 Toll Free: 1-800-361-1913
The use of the balanced hardware flow control lines is optional. If the h/w flow control lines are not required, configure as
follows:
J1 (CTS0) = Middle and Left pins shorted to DISABLE flow control on P1. Do not use pins 3 & 5 on the DB9M connector.
J3 (CTS1) = Middle and Left pins shorted to DISABLE flow control on P2. Do not use pins 3 & 5 on the DB9M connector.
J1 (CTS0) = Middle and Right pins shorted to ENABLE flow control on P1.
Connect RTS+,RTS- and CTS+,CTS- to your remote device.
That is,
J3 (CTS1) = Middle and Right pins shorted to ENABLE flow control on P2.
Connect RTS+,RTS- and CTS+,CTS- to your remote device.
Pin # 1 Ground
Pin # 2 CTS- (optional)
Pin # 3 RTS- (optional)
Pin # 5 RTS+ (optional)
Pin # 6 CTS+(optional)
Pin #7 TX+ / RX+
Pin #8 TX- / RX-
The use of the balanced hardware flow control lines is optional. If the h/w flow control lines are not required, configure as
follows:
J1 (CTS0) = Middle and Left pins shorted to DISABLE flow control on P1. Do not use pins 3 & 5 on the DB9M connector.
J3 (CTS1) = Middle and Left pins shorted to DISABLE flow control on P2. Do not use pins 3 & 5 on the DB9M connector.
OR
J1 (CTS0) = Middle and Right pins shorted to ENABLE flow control on P1.
Connect RTS+,RTS- and CTS+,CTS- to your remote device.
J3 (CTS1) = Middle and Right pins shorted to ENABLE flow control on P2.
Connect RTS+,RTS- and CTS+,CTS- to your remote device.
J2 will configure the slew rate for the interface on connector P1 (bottom DB9M).
2
3979 Tecumseh Road East, Windsor, Ontario, N8W 1J5 Canada
Voice: 1-519-974-0163 Fax: 1-519-974-0165 Toll Free: 1-800-361-1913
J4 will configure the slew rate for the interface on connector P2 (top DB9M).
This circuit board offers the option for 2 methods of termination for the Transmitter, Receiver, CTS and RTS lines for each
of the 2 serial ports.
S2_Switch 4: Off (Right) = No termination, ON (Left) = Terminate TX lines with onboard 120 ohm resistor (Port P1)
S2_Switch 3: Off (Right) = No termination, ON (Left) = Terminate RTS lines with onboard 120 ohm resistor (Port P1)
S2_Switch 2: Off (Right) = No termination, ON (Left) = Terminate CTS lines with onboard 120 ohm resistor (Port P1)
S2_Switch 1: Off (Right) = No termination, ON (Left) = Terminate RX lines with onboard 120 ohm resistor (Port P1)
S5_Switch 4: Off (Right) = No termination, ON (Left) = Terminate TX lines with onboard 120 ohm resistor (Port P2)
S5_Switch 3: Off (Right) = No termination, ON (Left) = Terminate RTS lines with onboard 120 ohm resistor (Port P2)
S5_Switch 2: Off (Right) = No termination, ON (Left) = Terminate CTS lines with onboard 120 ohm resistor (Port P2)
S5_Switch 1: Off (Right) = No termination, ON (Left) = Terminate RX lines with onboard 120 ohm resistor (Port P2)
Method # 2 – DO NOT use the Dip Switch S2 = Leave OFF. This method allows for user provided termination values.
R31 = User provided termination resistor for TX (through hole ¼ watt or higher) (Port P1)
R30 = User provided termination resistor for RX (through hole ¼ watt or higher) (Port P1)
R51 = User provided termination resistor for TX (through hole ¼ watt or higher) (Port P2)
R52 = User provided termination resistor for RX (through hole ¼ watt or higher) (Port P2)
S2_Switch 4: Off (Right) = No termination, ON (Left) = Terminate TX lines with onboard 120 ohm resistor (Port P1)
S2_Switch 3: Off (Right) = No termination, ON (Left) = Terminate RTS lines with onboard 120 ohm resistor (Port P1)
3
3979 Tecumseh Road East, Windsor, Ontario, N8W 1J5 Canada
Voice: 1-519-974-0163 Fax: 1-519-974-0165 Toll Free: 1-800-361-1913
Common Configuration Example # 2
S2_Switch 4: Off (Right) = No termination, ON (Left) = Terminate TX lines with onboard 120 ohm resistor (Port P1)
S2_Switch 3: Off (Right) = No termination, ON (Left) = Terminate RTS lines with onboard 120 ohm resistor (Port P1)
S5_Switch 4: Off (Right) = No termination, ON (Left) = Terminate TX lines with onboard 120 ohm resistor (Port P2)
S5_Switch 3: Off (Right) = No termination, ON (Left) = Terminate RTS lines with onboard 120 ohm resistor (Port P2)
S2_Switch 4: Off (Right) = No termination, ON (Left) = Terminate TX lines with onboard 120 ohm resistor (Port P1)
S2_Switch 3: Off (Right) = No termination, ON (Left) = Terminate RTS lines with onboard 120 ohm resistor (Port P1)
S5_Switch 4: Off (Right) = No termination, ON (Left) = Terminate TX lines with onboard 120 ohm resistor (Port P2)
S5_Switch 3: Off (Right) = No termination, ON (Left) = Terminate RTS lines with onboard 120 ohm resistor (Port P2)
4
3979 Tecumseh Road East, Windsor, Ontario, N8W 1J5 Canada
Voice: 1-519-974-0163 Fax: 1-519-974-0165 Toll Free: 1-800-361-1913
In RS485 mode of operation, the Transmitter will be AUTO-GATED (using the DTR line) for multi-drop applications. The
Receiver can be switch configured to either ENABLE or DISABLE the Local Echo.
For RS485 mode of operation, switch the dipswitch to the RS485 position. You must also select RS485 Active High
Mode under the serial port configuration. This configuration will toggle the DTR line HIGH during a byte transmit and
LOW otherwise.
Fail-Safe Biasing
Varying with your installation, external resistors may be required for fail-safe biasing of other devices in your
communication wiring. That is, to ensure an IDLE state during the absence of all transmitters in the RS485 interface,
external pull up resistor for the TX+/RX+ and an external pull down resistor for the TX-/RX- connection. Note: The
receivers used in the LF686KB design are internally fail-safe but other non-Axxon designs may not offer this feature.
Without a fail-safe biasing the receiver may pick up stray noise as a start bit causing data corruption.
The values for these resistors are based on the total load of the RS485 network. A common tested value is 330 ohms for
both the pull up and pull down leads. This value assumes that termination will be used, otherwise 4.7K is another choice.
Axxon uses 4.7k to fail-safe bias the externally connected devices, so termination should NOT be used. You may
use your own values as an option as noted.
Switch S3 & S6 permit selection between Axxon or user provided fail-safe resistors.
S3_Switch 1: Off (Right) = No fail-safe resistor on RX+ OR User provided fail-safe resistor using R43 (Pull-Up)
S3_Switch 1: ON (Left) = 4.7k Fail-safe resistor on RX+ (User provided fail-safe resistor at R43 should not be
installed)
S3_Switch 2: Off (Right) = No fail-safe resistor on TX- OR User provided fail-safe resistor using R41 (Pull-Down)
S3_Switch 2: ON (Left) = 4.7k Fail-safe resistor on TX- (User provided fail-safe resistor at R41 should not be
installed)
S3_Switch 3: Off (Right) = No fail-safe resistor on RX- OR User provided fail-safe resistor using R42 (Pull-Down)
S3_Switch 3: ON (Left) = 4.7k Fail-safe resistor on RX- (User provided fail-safe resistor at R42 should not be
installed)
S3_Switch 4: Off (Right) = No fail-safe resistor on TX+ OR User provided fail-safe resistor using R39 (Pull-Up)
S3_Switch 4: ON (Left) = 4.7k Fail-safe resistor on TX+ (User provided fail-safe resistor at R39 should not be
installed)
R43 = User provided Pull Up resistor for RX+ (through hole ¼ watt or higher) (Port P1)
R41 = User provided Pull Down resistor for TX- (through hole ¼ watt or higher) (Port P1)
R42 = User provided Pull Down resistor for RX- (through hole ¼ watt or higher) (Port P1)
R39 = User provided Pull Up resistor for TX+ (through hole ¼ watt or higher) (Port P1)
5
3979 Tecumseh Road East, Windsor, Ontario, N8W 1J5 Canada
Voice: 1-519-974-0163 Fax: 1-519-974-0165 Toll Free: 1-800-361-1913
S6 is for the fail-safe biasing configuration of connector P2
S6_Switch 1: Off (Right) = No fail-safe resistor on RX+ OR User provided fail-safe resistor using R67 (Pull-Up)
S6_Switch 1: ON (Left) = 4.7k Fail-safe resistor on RX+ (User provided fail-safe resistor at R67 should not be
installed)
S6_Switch 2: Off (Right) = No fail-safe resistor on TX- OR User provided fail-safe resistor using R65 (Pull-Down)
S6_Switch 2: ON (Left) = 4.7k Fail-safe resistor on TX- (User provided fail-safe resistor at R65 should not be
installed)
S6_Switch 3: Off (Right) = No fail-safe resistor on RX- OR User provided fail-safe resistor using R64 (Pull-Down)
S6_Switch 3: ON (Left) = 4.7k Fail-safe resistor on RX- (User provided fail-safe resistor at R64 should not be
installed)
S6_Switch 4: Off (Right) = No fail-safe resistor on TX+ OR User provided fail-safe resistor using R63 (Pull-Up)
S6_Switch 4: ON (Left) = 4.7k Fail-safe resistor on TX+ (User provided fail-safe resistor at R63 should not be
installed)
R67 = User provided Pull Up resistor for RX+ (through hole ¼ watt or higher) (Port P1)
R65 = User provided Pull Down resistor for TX- (through hole ¼ watt or higher) (Port P1)
R64 = User provided Pull Down resistor for RX- (through hole ¼ watt or higher) (Port P1)
R63 = User provided Pull Up resistor for TX+ (through hole ¼ watt or higher) (Port P1)
6
3979 Tecumseh Road East, Windsor, Ontario, N8W 1J5 Canada
Voice: 1-519-974-0163 Fax: 1-519-974-0165 Toll Free: 1-800-361-1913
Reference reading documents:
MAX3079EESD+ datasheet:
http://pdfserv.maxim-ic.com/en/ds/MAX3070E-MAX3079E.pdf
Questions? Please contact us via email: support@softio.com or phone: 1-800-361-1913 to speak with our Tech Support
staff from 10 AM to 6 PM (EST).
7