Pentair Mecair Non-Immersion Header Tank Systems
Pentair Mecair Non-Immersion Header Tank Systems
Pentair Mecair Non-Immersion Header Tank Systems
5”–10”
NON-IMMERSION
HEADER TANKS
CLEAN AIR SOLUTIONS PRODUCT LEAFLET
MECAIR - 5”–10”
NON-IMMERSION HEADER TANKS
PRODUCT LEAFLET
Mecair manufactures a wide range of The tank volume must be proportional to the output capacity of the installed diaphragm
tanks for the pulse-jet dust collector valve:
filters, complying with the following
1. Choose your Mecair diaphragm valve, according to needs.
European Directive: 97/23/CE (PED). Mecair
also manufactures pressure vessels in 2. Define tank length.
accordance with the American Code, ASME
VIII Div.1 (“U” and “UM” Stamp). Models 3. Using the table below, select the right tank diameter.
of tanks manufactured are listed below as 4. Write down the tank code.
follows:
TANK TYPE A: with threaded stub pipes male
Gas (for the 200 Series valves). NOTE: The diaphragm valves mentioned in this publication refer to the specific Mecair
TANK TYPE B: with unthreaded stub pipes products catalogue. (VEM: diaphragm valve with remote pilot. VNP: diaphragm valve with
(for the 300 Series valves). integrated pilot.)
TANK TYPE D: with welded flanges (for the
600 and 700 Series valves). VALVE TYPE 1 MT. 1.5 MT. 2 MT. 3 MT. 4 MT. 5 MT.
VEM/VNP 206 - 306 6” 5” 5” 5” 5” 5”
VEM/VNP 208 - 308 6” 6” 6” 5” 5” 5”
HEADER TANK VEM/VNP 214 - 314 - 608 - 708 8” 8” 6” 6” 6” 5”
VEM/VNP 216 - 614 - 714 10” 10” 10” 8” 6” 6”
The tanks manufactured by Mecair are VEM/VNP 220 - 616 - 716 10” 10” 8” 8”
designed for a maximum operating pressure
of 8 bar. We suggest the installation of
compressed-air filter units to ensure air
supply is clean and dry. Tank diameters HOW TO ORDER
range from 5”, 6”, 8”, 10”, 12” to 14”. All
tanks are manufactured in accordance with
the customer’s requirements. Part Number Code: S 6 A 08 N12 P150
NOTE: add “F” at the end of the key for tank
with flat end caps (only on request). S P
Tank Distance between outlets (mm)
Tank diameter N
• 5“ Number of outlets
• 6“
• 8“ Valve type (specify VNP or VEM)
• 10“ 06 = ¾“
• 12“ 08 = 1“
14 = 1½“ (single/double diaphragm)
Type of valve connection 16 = 2“
A Threaded stub pipes (Series 200) 20 = 2½“
B Unthreaded stub pipes (Series 300)
D Flanged stubs (Series 600/700)
TANK TYPE “A” WITH THREADED STUB PIPES GAS OR NPT MALE
Lo c k nu t
L 2K + 2R + (No. − 1) × P
NO. No. of connections
P Distance between connections
L 2K + 2R + (No. − 1) × P
NO. No. of connections
P Distance between connections
L 2K + 2R + (No. − 1) × P
NO. No. of connections
P Distance between connections