L K B ENGINEERING PV T L TD

Regd. Office: A -56/1, Mayapuri Industrial A rea, Phase-II, Mayapuri, New Delhi-110064
Cust. Care-: 1800-11-2311 (Toll Free) Email ID: marketing@rallison.com www.rallison.com

PR IC E L IST ( F L E X IBL E C A BL E S ) wef. 22.07.2022


"R A L L IS ON" Multis tranded C opper C onductor Indus trial cable , HR F R /F R L S PV C /ZHF R Ins ulated 1100 volts confirming to IS
694/1990
Mas ter
C urrent
S . No. C ond. A rea C ond. C onst. C arton R s. per 180 mtrs . C oil
R ating
(C oils )
(S qmm) (No/dia in mm) (Amp) 180Mtrs HR F R PV C F R LS PV C ZHF R FS
1 0.75 24/0.2 8 12 2655 2730 2835 3980
2 1 14/0.3 13 12 3475 3585 3720 5220
3 1.5 22/0.3 18 10 5120 5275 5480 7680
4 2.5 36/0.3 24 5 8320 8570 8900 12480
5 4 56/0.3 32 4 12635 13015 13515 18955
6 6 84/0.3 41 3 18900 19470 20225 28355
"R A L L IS ON" F lexible Indus trial C ables , C opper C onductor, HR F R PV C Ins ulated 1100 volts confirming to IS 694/1990
C urrent R s . per 100 R s . per 100 mtrs . R s . per 100mtrs
S . No. C ond. Area C ond. C ons t.
R ating mtrs . C oil C oil C oil
(S qmm) (No/dia in mm) (Amp) HR F R PV C F R LS PV C ZHF R
7 0.5 16/0.2 5 1070 1105 1150
8 0.75 24/0.2 8 1540 1590 1650
9 1 32/0.2 13 2020 2080 2160
10 1.5 30/0.25 17 2855 2945 3055
11 2.5 50/0.25 24 4735 4875 5070
12 4 56/0.3 30 7285 7505 7795
13 6 84/0.3 38 10845 11170 11605
14 10 80/0.4 52 18645 19200 19950
15 16 126/0.4 70 30150 31060 32260
16 25 196/0.4 88 47085 48495 50380
17 35 276/0.4 110 65345 67305 69920
18 50 396/0.4 145 92645 95425 99130
19 70 354/0.5 215 130025 133925 139125
20 95 484/0.5 260 177395 182715 189810
21 120 608/0.5 305 231705 238655 247920
22 150 750/0.5 355 288395 297050 308580
23 185 925/0.5 415 356590 367290 381555
24 240 1210/0.5 500 459985 473780 492185
25 300 1527/0.5 585 573550 590760 613700
26 400 2036/0.5 695 763595 786500 817045

"R A L L IS ON" Telephone C ables confirming to ITD s pecification S /WS -113C & 114D and colour code as per ITD S /WS -129D

R ate R s . per 90 mtrs. C oil


S . No. No of Pairs
C ond. Dia 0.40 mm C ond. dia 0.50 mm C ond. dia 0.60 mm
27 1 (F lat) 775 1145 1440
28 2 1255 1945 2450
29 3 1810 2800 3510
30 4 2315 3685 4630
31 5 2990 4385 5500
32 10 5965 9055 11360
33 20 11945 18340 22765
34 50 29715 43665
35 100 59250 87325
As per International practice which is also adopted by Bureau of Indian S tandards, the diameter of the condutcotr shown above is normal. The size of the
1
conductor is determined by resistance. The construction of the condutor is as per market convention.
2 This cancels all our previous Price - Lists
3 R ates are exclusive of S ales Tax, Octroi etc and are subject to change without notice
4 All disputes are subject to Delhi jurisdiction only.
LK B ENGINEERING PV T LTD
Regd. Office: A -56/1, Mayapuri Industrial Area, Phase-II, Mayapuri, New Delhi-110064
Tel:-:91-11-42015577 Email ID:marketing@rallison.com www.rallison.com

PR IC E L IST ( F L E X IBL E C A BL E S ) wef. 22.07.2022


"R AL L IS ON" F lexible Indus trial C ables ,C opper C onductor, HR PV C Insulated & F R PV C s heathed 1100 volts confirming to IS
694/1990
S . No C onductor Area C onduc tor C ons t. C urrent R ating R ate R s . per 100 mtrs . C oil

Pac king Pac king Pac king


(S qmm) (No/dia in mm) (Amp) T wo C ore T hree C ore F our C ore
(C oils ) (C oils ) (C oils )
36 0.5 16/0.2 5 3445 5 4555 3 5675 2
37 0.75 24/0.2 8 4695 5 5980 3 7715 2
38 1 32/0.2 13 5230 4 7130 2 9370 2
39 1.5 30/0.25 17 7130 3 9965 2 12860 2
40 2.5 50/0.25 24 11555 2 16020 1 20990 1
41 4 56/0.3 30 18020 1 26065 1 33545 1
42 6 84/0.3 38 26565 1 37760 1 50360 1
43 10 140/0.3 52 44400 1 63740 1 84110 1
44 16 226/0.3 70 68390 1 97980 1 129325 1
45 25 157/0.45 88 108105 1 157695 1 207000 1
46 35 220/0.45 110 149065 219285 285955
47 50 314/0.45 145 213570 314010 410500
48 70 360/0.5 216 297375 433315 570165
49 95 480/0.5 262 528880 754400
50 120 608/0.5 310 687540 908935
3% extra applic able on Drum Packing .
F R L S L oading 7.5% extra upto 1 S qmm and 5% extra on above
"R AL L IS ON" F lexible Indus trial C ables , C opper C onductor, HR P V C Ins ulated & F R PV C s heathed 1100 volts confirming to IS 694/1990
R ate R s . per 100 mtrs . C oil
S . No. No of C ores 0.75 s qmm 2.5S qmm 4S qmm 6S qmm
0.5 s qmm (16/0.2) 1 s qmm (32/0.2) 1.5 s qmm (30/0.25)
(24/0.2) (50/0.25) (56/0.3) (84/0.3)
51 5 7715 10640 12390 17295 27425 45010 64815
52 6 8935 12140 14705 20250 32425 51565 78630
53 7 9740 13400 16510 22705 36205 59740 93390
54 8 10550 14970 19025 26650 42655 69025 108115
55 10 15120 20370 25020 33770 53490 87900 135885
56 12 17465 23675 28935 39730 63315 104240 159230
57 14 19915 27335 33435 46020 74055 120890 186560
58 16 22730 31130 38150 52555 84100 137545 213130
59 19 26260 36150 44195 61055 98445 161555 252380
60 24 33585 46195 56350 78140 125705 207610 315545
3% extra applic able on Drum Packing .

"R AL L IS ON" 3 core F lat S ubmers ible C ables , C opper C onductor, HR P V C Ins ulated & F R PV C s heathed 1100 volts

C onductor
S . No. C onductor Area C urrent R ating R ate R s .
C ons truc tion
(S qmm) (No/dia in mm) (Amp) 100 mtrs . C oil
61 1.5 22/0.3 17 10240
62 2.5 36/0.3 24 15835
63 4 56/0.3 30 23545
64 6 84/0.3 38 35055
65 10 140/0.3 52 59020
66 16 101/0.45 70 93270
67 25 157/0.45 88 140175
68 35 220/0.45 110 202945
69 50 314/0.45 145 249125
3% extra applic able on Drum Packing .

As per International practice which is also adopted by Bureau of Indian S tandards, the diameter of the condutcotr shown above is normal. The size of
1 the conductor is determined by resistance. The construction of the condutor is as per market convention.
2 This cancels all our previous P rice - Lists
3 R ates are exclusive of S ales Tax, Octroi etc and are subject to change without notice
4 All disputes are subject to Delhi jurisdiction only.
L K B ENGINEERING PV T L TD
Regd. Office: A -56/1, Mayapuri Industrial A rea, Phase-II, Mayapuri, New Delhi-110064
T :011-42015577 Email ID: marketing@rallison.com www.rallison.com

L IST PR IC E NO 02/2022-23 05/07/2022

RA LLISON Brand Power Cables, Solid Aluminium conductor upto 10 sqmm balance stranded conductor, X LPE Insulated, cores laid up, PV C tape
innersheath, unarmoured / A rmour (Aluminium wire for single core up to 70 sqmm balance A luminium strip, Glavanised wire for cables upto 2 x 10
sqmm, 3 x 10sqmm, 4 x 6 sqmm balance all galvansed steel strip), extruded PV C T ype ST 2 sheath, 650/1100V grade as per IS 7098 (Part I) 1988

(Rate in Rs. Per Metre)


UN A R MOUR E D A R MOUR E D
C able C ore -1 C ore - 2 C ore -3 C ore -3.5 C ore -4 C ore -1 C ore - 2 C ore -3 C ore -3.5 C ore -4 C able
Size in Size in
A 2X W aY A 2X W Y A 2X W Y A 2X W Y
sqmm A 2X Y A 2X Y A 2X Y A 2X Y A 2X Y A 2X F Y sqmm
A 2X F aY A 2X F Y A 2X F Y A 2X F Y
4 74 93 111 128 145 170 4
6 103 123 150 168 181 217 6
10 140 168 197 197 231 262 10
16 76 138 189 250 139 201 239 313 16
25 118 208 281 357 375 181 265 324 382 406 25
35 146 273 387 419 465 215 311 426 460 520 35
50 187 342 477 569 622 260 395 549 620 692 50
70 248 493 686 776 894 333 554 738 827 942 70
95 326 573 835 987 1064 370 665 905 1051 1154 95
120 390 714 1090 1269 1291 447 810 1150 1311 1436 120
150 469 888 1258 1485 1600 526 1016 1338 1518 1710 150
185 576 1059 1585 1899 1979 644 1213 1684 1948 2160 185
240 680 1386 2046 2279 2638 818 1552 2146 2463 2770 240
300 847 1693 2507 2954 3213 1006 1891 2654 3056 3495 300
400 1063 2114 3128 3692 4230 1269 2327 3422 3866 4410 400
500 1391 2602 4194 4917 5584 1550 3117 4400 5100 5900 500
630 1747 3314 5524 6522 7473 1909 3924 5745 6790 7803 630
800 2220 2378 800
1000 2856 3005 1000

E X T R A F OR SPE C IA L C ONST R UC T ION:


a) Round Wire A rmouring F R L S L oading F actor L SZ H
C able Size
- 2 x 16 & above 25.00% Inner Outer Sheath Inner Outer
(Sqmm)
- 3 x 16 & 3.5C x 25 & above 25.00% Sheath A rmd. Unarmd Sheath Sheath
- 4 x 10 & above 25.00% Power (A l.)
- For Single core 95 & above 25.00% Upto 16 10.0% 15.0% 15.0% 15.0% 20%
b) Stranding 10 sqmm and below 10.00% 25-50 7.5% 10.0% 12.5% 12.5% 15%
c) Extruded PV C Innersheath Up 50 5.00% 70 & above 5.0% 7.5% 7.5% 15.0% 12.5%
Extruded PV C Innersheath 70 & above 2.50% Power Single C ore (A l.)
d) HR PV C Insulation 10.00% Upto 16 - NA- 20.0% 20.0% 25% 25%
e) HR PV C Inner Sheath 5.00% 25-70 - NA- 15.0% 15.0% 20% 20%
f) HR PV C Outer Sheath 5.00% 95 & above - NA- 12.5% 12.5% 17.5% 17.5%
g) Oxygen Index (FR) 2.50%
h) PV C Insulated Cables 8.00%

* The above rates are exclusive of GST & any other statutory levies which shall be charged extra
* This cancels all our previous Price Lists, T his Price List is subject to change without prior notice
LK B ENGINEERING PV T LT D
Regd. Office: A -56/1, Mayapuri Industrial A rea, Phase-II, Mayapuri, New Delhi-110064
T:011-42015577 Email ID: marketing@rallison.com www.rallison.com

L IST PR IC E NO 02/2022-23 05/07/2022


RA LLISON Brand Power/Control Copper Cables, Solid Copper conductor, X LPE Insulated, cores laid up, PV C tape innersheath, unarmoured / A rmour
(Galvanised wire for cables upto 10 x 1.5 sqmm, 8 x 2.5 sqmm, 2 x 10 sqmm, 3 x 10 sqmm, 4 x 6 sqmm balance all galvansed steel strip), extruded PV C
Type ST2 sheathed, 650/1100V grade as per IS 7098 (Part I) 1988
(Rate in Rs. Per Metre)
UN A R MOUR E D A R MOUR E D
C able C able
Size in C ore -1 C ore - 2 C ore -3 C ore -3.5 C ore -4 C ore -1 C ore - 2 C ore -3 C ore -3.5 C ore -4 C ore -5 Size in
sqmm 2X W aY 2X W Y 2X W Y 2X W Y 2X W Y sqmm
2X Y 2X Y 2X Y 2X Y 2X Y 2X F Y
2X F aY 2X F Y 2X F Y 2X F Y 2X F Y
4 232 330 402 273 366 461 576 4
6 329 468 569 373 506 652 793 6
10 572 786 940 594 813 1038 1292 10
16 407 730 1122 1406 487 797 1170 1507 2010 16
25 643 1210 1685 1881 2205 737 1250 1782 2143 2348 3138 25
35 871 1662 2308 2640 3080 992 1748 2468 2800 3246 4364 35
50 1248 2278 3198 3771 4189 1394 2367 3400 3937 4482 5822 50
70 1736 3024 4554 5425 6377 1928 3272 4798 5640 6665 70
95 2364 4204 6483 7516 8362 2477 4455 6620 7552 8657 95
120 2959 5143 7627 9811 10528 3073 5312 8158 9970 11012 120
150 3639 6437 9687 11094 13025 3766 6651 10120 11500 13300 150
185 4509 7939 11965 14016 16533 4606 8233 12700 14830 16870 185
240 5807 10165 15868 18436 21305 5872 10607 16500 19080 21740 240
300 7304 12666 19371 22806 26328 7417 13434 20470 24000 27662 300
400 9603 16906 24797 28405 33156 9950 18275 27000 30900 35400 400
500 12224 12305 500
630 15389 15471 630
800 19491 19581 800
1000 24368 24614 1000
C ONT R OL C A BL E S (R ate in R s. Per Metre)
UN A R MOUR E D A R MOUR E D UN A R MOUR E D A R MOUR E D
No. of No. of No. of No. of
2X Y 2X W Y /2X F Y 2X Y 2X W Y /2X F Y
C ores C ores C ores C ores
1.5sqmm 2.5sqmm 1.5sqmm 2.5sqmm 1.5sqmm 2.5sqmm 1.5sqmm 2.5sqmm
2 112 161 152 208 2 14 509 914 615 961 14
3 141 226 184 270 3 16 612 1047 690 1091 16
4 182 296 227 339 4 19 733 1261 819 1308 19
5 223 355 272 395 5 24 928 1593 1025 1638 24
6 263 409 320 477 6 27 999 1960 1110 2036 27
7 304 474 357 522 7 30 1204 2194 1257 2365 30
8 383 537 435 590 8 37 1613 2576 1700 2752 37
10 446 671 492 740 10 44 1948 3016 2113 3315 44
12 460 812 540 850 12 61 2936 4294 3084 4720 61

E X T R A F OR SPE C IA L C ONST R UC T ION (C ONT R OL C A BL E S): E) OX Y GEN INDEX (FR) 2.50%


A ) Tinning 3.00% F) HR PV C INSULA TION 7%
B) Stranding (Upto 6 Sqmm) 6.00% HR I/SH. & O/SH 5% EA CH
C) Extruded Innersheath 2.50% G) FRLS Loading-Power Cable 7.50%
D) Round Wire A rmouring H) PV C Insulated Cables 5%
S/C x 95 sqmm & above 7.50% F R L S L oading F actor - C ontrol C able L SZ H
1.5 sqmm - 12 core & above 15.00% Inner Outer Sheath Inner Outer
C ores
2.5 sqmm - 9 core & above 15.00% Sheath A rmd. Unarmd Sheath Sheath
10 sqmm - 4 core & above 15.00% 2-4 10.0% 10.0% 10.0% 15.0% 15.0%
16 sqmm - 2 core & above 15.00% 5 - 10 7.5% 10.0% 10.0% 15.0% 15.0%
16 sqmm - 3 core & above 15.00% 12 & above 7.5% 7.5% 7.5% 12.5% 12.5%
A s per international practice which is also adopted by BIS, the size of the conductor is decided by its resistance only. The construction of the conductor
mentioned in the price list are only for guide-lines and are as per market convention. It may vary within the prescribed limit of IS 8130-1994 with related
classes and tables
* The above rates are exclusive of GST & any other statutory levies which shall be charged extra
* This cancels all our previous Price Lists, This Price List is subject to change without prior notice

Powered by TCPDF (www.tcpdf.org)