FlexKraft offers a complete range of switch mode DC power supplies for industrial applications in harsh environments.
The compact and modular design offers many benefits to the user.
FLEXIBILITY
Besides regular voltage control and current control, FlexKraft HIGH POWER FACTOR
also offers power control that allows the use of a wide voltage and Low reactive power consumption throughout the range reduces
current output range. installation and electrical cost.
ISO 9001
S 107.050 GB
The FlexKraft rectifiers are designed to give the best electrical BLOCK SCHEMATIC DIAGRAM
performance in demanding industrial environments. The design
is based on primary switching technology.
The rectifiers consist of 1–10 power modules. Together with a
control module, they form a complete power supply.
CONTROL PARAMETERS
Setting: Outputs:
Set current Actual current
Set voltage Actual voltage
On / Off On signal
Start / Stop Run signal
Stand by / Run Actual Amp hours
Amp hours Actual run time
Run time Alarm (general alarm)
Clear counters Alarm status (cause of alarm)
End of process
TECHNICAL DATA
Supply voltage: 380 - 480 VAC ± 10%, 50 - 60 Hz, 3 Phase
220 VAC ± 10%, 50 - 60 Hz, 3 Phase
for maximum 2x7 VDC / 300A per module
EMC conformity: According to EN 61000-6-4, Emissions, and
EN 61000-6-2, Immunity OPTIONS
LVD conformity: According to EN 50178
- R emote control box ’basic version’ with analogue or digital
Protection class: IP 32 (except for fan)
display, potentiometers etc.
Power factor: ≥ 0.93 @ rated load
Efficiency: Typical 0.9 @ rated output - RS 232C interface control of one dual power supply.
Ambient temp.: Max. 40˚C, de-rated operation up to 50˚C - A nalogue/Digital interface. Four analogue inputs and four
Cooling: Forced air cooling analogue outputs 0-10VDC and 4 digital in and 4 digital out
Humidity: Max. 95% RH, non-condensing 24VDC.
Control precision: Voltage/current < ± 1% - Standard configuration: Iset, Uset, Iact and Uact: 0-10 VDC.
DC ripple: ≈ 1% of rated output current at constant On/Off, Block/Run, Power On and Alarm as digital signals: 24
current mode in the entire range of regulation VDC.
Regulation range: Stepless at constant voltage or current 0–100% - A nalogue interface with four inputs and four outputs
Duty ratio: Designed for continuous operation at rated galvanically isolated. Control and status signals either
load up to 1000 m altitude 0-10 VDC or 0/4-20 mA. Standard configuration: Iset, Uset, Iact
Protection: Over-current and Uact: 0-10 VDC
Over-voltage - D igital interface with four inputs and four outputs. Control
Overtemperature signals 24 VDC. Status signals via voltage free relay contacts;
Short circuit contact data 24 VDC or 24 VAC. Standard configuration:
Open circuit On/Off, Block/Run, Power On and Alarm.
Module failure - Raise / Lower function.
- Electrically controlled AC breaker.
- External reference shunt, 60 mV.
- Polarity Reversal.