Auditorium RT60 Calculation
Auditorium RT60 Calculation
Auditorium RT60 Calculation
BOARD
FOR RT 60 CALCULATION FOR AUDITORIUM
ACCOUSICS
CONTROL
6000.0
ROOM CONSIDER L = 27.5M B= 27M H= 6M
BACK
STAGE THEREFORE VOLUME OF AUDITORIUM = 4455 CU M
900.0
TO FLOOR RT = 0.16 X VOL. OF AUDITORIUM/ TOTAL ABSORBING POWER
WHERE, A = a1s1+a2s2+a3s3......
a = AREA OF SURFACE COEFFICIENT OF ABSORPTION
SECTION AT AA' s = TOTAL SURFACE AREA
FOR FLOORING,
GREEN GREEN FLOORING AREA = 27.5X27 = 742.5SQ M
ROOM ROOM SURFACE COEFFICIENT OF FLOORING s1 = 0.30
(FEMALE) (MALE) (CONSIDER CARPET 6MM FLUSH TO FLOOR)
= 742.5X0.30 = 222.750------------a1s1
FOR CEILING,
CEILING AREA = 27.5x27 = 742.5 SQ M
SURFACE COEFFICIENT OF CEILING s2 = 0.07
(CONSIDER GYPSUM BOARDS ON STUDS OR JOIST)
STORE ROOM =742.5X 0.07= 51.975---------a2s2
FOR WALL,
CONSIDER 10% ACOUSTIC TREATMENT TO THE WALLS
SURFACE COEFFICIENT OF WALL s = 0.07
(CONSIDER .02 FOR GYPSUM AND PLASTER WALL)