Nothing Special   »   [go: up one dir, main page]

4 - 3D Ah-5vcm

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

Index Maintenance Manuals Technical Data Drawing Information

PUMP FRAME KW RATING


SIZE CAM 30 PUMP
For contact details -
4/3
PERFORMANCE
CCAM 55
visit www.warman.co.za CURVE
D* 60 REFERENCE
TYPE DD 110
IMPELLER D3147 LINER
WPG
AH VANES TYPE MAT’L VANE O MAT’L
43AH30
5 CLOSED METAL 245 METAL
COPYRIGHT RESEARCH AND DEVELOPMENT PTY LTD
Reprinted
GLAND SEAL PUMP June 2004

Last Issue: November 2002


WE RESERVE THE RIGHT TO MODIFY OR DELETE
IMPELLERS WITHOUT PRIOR NOTICE POWER CONSUMTION MAY INCREAS BY 5% WITH CENTRIFUGAL SEAL
MIN PASSAGE SIZE
CURVE SHOWS APPROXIMATE PERFORMANCE FOR CLEAR WATER (IN ACCORDANCE NORM MAX RPM
WITH PUMP TESTING ISO9906-1999 GRADE 2 (IS02548 CLASS C)). FOR MEDIA OTHER 36 mm
THAN WATER, CORRECTIONS MUST BE MADE FOR DENSITY, VISCOSITY AND/OR THE
2750 SPHERE
PRESENCE AND EFFECTS OF SOLIDS
* Indicates standard frame size fitted, refer to Head Office for availability of frame sizes quoted, other than standard. Operating pumps over maximum speed refer to Head Office.
Rated kilowatts is the maximum that any particular bearing assembly can transmit and is not the maximum motor frame size that can be fitted to any particular bearing assembly.

90

2750 30% 40%


r/min 50%
80 60%
2600 65%

70

2400 68%

60
65%

Test Date: November 2002


2200
H (m)

50

2000

40
1800

30 1600

1400
20
1200
Reference Test: RB0138

1000
10

0 90
0 10 20 30 40 50 60 70 80

20
Q (l/sec)

16
2750
r/min
NPSH (m)

12

8
Revision: 0