Operators Manual Handheld Multi-Purpose Interface (HHMPI) : 19 October 2018 30-0005 Issue E
Operators Manual Handheld Multi-Purpose Interface (HHMPI) : 19 October 2018 30-0005 Issue E
Operators Manual Handheld Multi-Purpose Interface (HHMPI) : 19 October 2018 30-0005 Issue E
30-0005 Issue E
Operators manual
4.0 Operation 20
4.1 Download file name . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 4.3.2 Decompressing CVR data at the aircraft . . . . . . . . . . 25
4.2 Aircraft lists. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 4.3.3 Decompressing CVR away from the aircraft . . . . . . . 26
4.2.1 Loading aircraft details . . . . . . . . . . . . . . . . . . . . . . . . . 20 4.3.4 Using the CVR Rack Adaptor or Aircraft Power Cable.
27
4.2.2 Creating an Aircraft List on a PC . . . . . . . . . . . . . . . . . 21
4.4 Viewing live flight data . . . . . . . . . . . . . . . . . . . . . . . . . . 28
4.2.3 Transferring the Aircraft List to the HHMPI . . . . . . . . 21
4.4.1 Live Data View Options. . . . . . . . . . . . . . . . . . . . . . . . . 29
4.2.4 Creating the Aircraft List on the HHMPI . . . . . . . . . . 22
4.4.2 Adjusting ARINC 717 settings . . . . . . . . . . . . . . . . . . . 29
4.2.5 Adding Entries to the HHMPI Aircraft File . . . . . . . . . 22
4.4.3 Changing the display format . . . . . . . . . . . . . . . . . . . . 30
4.2.6 Deleting an aircraft from the Aircraft list on the HHMPI
22 4.5 Viewing live flight data in engineering units . . . . . . . . 31
4.2.7 Saving the Aircraft list to the USB flash drive on the 4.5.1 Assigning an Aircraft Definition file to an aircraft . . 31
HHMPI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
4.5.2 Viewing Live Flight Data . . . . . . . . . . . . . . . . . . . . . . . . 32
4.2.8 Deleting all aircraft from the Aircraft list on the HHMPI
4.6 File transfer operations . . . . . . . . . . . . . . . . . . . . . . . . . . 34
23
4.6.1 File transfer between HHMPI storage locations . . . . 34
4.2.9 Prompt for Tail No. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
4.6.2 Other storage operations . . . . . . . . . . . . . . . . . . . . . . . 34
4.3 Downloading flight data . . . . . . . . . . . . . . . . . . . . . . . . . 24
4.6.3 File transfer PC to HHMPI. . . . . . . . . . . . . . . . . . . . . . . 34
4.3.1 Downloading recorded data from the FDR to a USB
flash drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 4.7 Network operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
4.7.1 DHCP network settings . . . . . . . . . . . . . . . . . . . . . . . . . 35
2
Handheld Multi-Purpose Interface (HHMPI)
39 5.4.3 Restoring backup files via the web interface . . . . . . 43
5.4.1 Changing the HHMPI configuration via the web inter- 5.4.4 Administration settings. . . . . . . . . . . . . . . . . . . . . . . . . 43
face. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
5.4.5 Logging out of the web interface . . . . . . . . . . . . . . . . 44
5.4.2 Backing up the HHMPI configuration. . . . . . . . . . . . . 42
7.0 Troubleshooting 46
8.0 FA2100, FA2200 and FA2300 Interface Supplement 50
8.1 Download Operations . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 8.8 Dump Fault Log. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
8.2 Recorder Operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 8.9 Dump Debug Trace . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
8.3 FDR Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 8.10 Memory Marker . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
8.4 CVR Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 8.11 Audio Operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
8.5 FDR or CVR Fault Output. . . . . . . . . . . . . . . . . . . . . . . . . 51 8.12 Live Data View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
8.6 Clear Latched Fault . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 8.13 Menu Tree . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
8.7 Clear Fault Log. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
15.0 Penny & Giles Multi-purpose flight recorder (MPFR) 051615 series 65
15.1 Download Operations . . . . . . . . . . . . . . . . . . . . . . . . . . 65 15.3 Menu Tree . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
15.2 Recorder Operations . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
3
FDS40-0301
16.0 Lockheed L-209 (Plessey PV-1584) 67
16.1 Download Operations . . . . . . . . . . . . . . . . . . . . . . . . . . 67
4
Handheld Multi-Purpose Interface (HHMPI)
Record of changes
List of figures
Figure 1.0 HHMPI front view . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Figure 2.0 HHMPI top view . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Figure 3.0 HHMPI bottom view . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Figure 4.0 HHMPI Mod 1 top view . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Figure 5.0 HHMPI Mod 1 bottom view. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Figure 6.0 HHMPI kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Figure 7.0 Connecting the HHMPI to the FDR or CVR . . . . . . . . . . . . . . . . . . . . . . . . . 15
Figure 8.0 The Battery Status screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Figure 9.0 HHMPI power-on sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Figure 10.0 Creating an Aircraft List in Notepad. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Figure 11.0 Adding aircraft to the Aircraft List on the HHMPI . . . . . . . . . . . . . . . . . . . 22
Figure 12.0 Configuring the prompt for tail number option . . . . . . . . . . . . . . . . . . . . 24
Figure 13.0 Downloading progress bar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Figure 14.0 Downloading and decompressing CVR data . . . . . . . . . . . . . . . . . . . . . . . 26
Figure 15.0 Decompressing Honeywell CVR file away from the aircraft . . . . . . . . . . . 27
Figure 16.0 Viewing live data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Figure 17.0 ARINC 717 settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Figure 18.0 Multiple live data view . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Figure 19.0 Word offset adjust. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Figure 20.0 Selected tail number on the shortcut screen . . . . . . . . . . . . . . . . . . . . . . . 32
Figure 21.0 Changing from Raw Mode to EU Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Figure 22.0 Accessing aircraft parameters alphabetically . . . . . . . . . . . . . . . . . . . . . . . 33
Figure 23.0 Four parameters populated with Engineering Units . . . . . . . . . . . . . . . . . 34
Figure 24.0 DHCP or manual IP configuration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
5
FDS40-0301
Introduction
List of tables
Table 1.0 Record of changes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Table 2.0 HHMPI models and description of modifications applied . . . . . . . . . . . . . 7
Table 3.0 HHMPI equipment list. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Table 4.0 Interface cables and software options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Table 5.0 Specifications HHMPI Mod 5 (no battery). . . . . . . . . . . . . . . . . . . . . . . . . . 12
Table 6.0 Specifications HHMPI Mod 1 and 5 (battery) . . . . . . . . . . . . . . . . . . . . . . . 12
Table 7.0 Troubleshooting common issues with the HHMPI . . . . . . . . . . . . . . . . . . 47
Table 8.0 File extensions of files downloaded from the FA2100 . . . . . . . . . . . . . . . 50
Table 9.0 Additional menu items for FA2100 CVFDR . . . . . . . . . . . . . . . . . . . . . . . . . 52
Table 10.0 File extensions of files downloaded from the SRVIVR™ . . . . . . . . . . . . . . 54
Table 11.0 Additional menu items for SRVIVR™ CVFDR . . . . . . . . . . . . . . . . . . . . . . . 56
Table 12.0 Additional menu items for FA5000/FA5001 CVFDR . . . . . . . . . . . . . . . . . 60
Table 13.0 File extensions of files downloaded from the L-3 A200S . . . . . . . . . . . . . 62
Table 14.0 File extensions of files downloaded from the Smiths VADR . . . . . . . . . . 62
Table 15.0 File extensions of files downloaded from the Universal CVFDR . . . . . . . 64
Table 16.0 File extensions of files downloaded from the 91005. . . . . . . . . . . . . . . . . 65
Table 17.0 File extensions of files downloaded from the MPFR . . . . . . . . . . . . . . . . . 65
Table 18.0 Additional menu items for MPFR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
Table 19.0 File extensions of files downloaded from the L-209 . . . . . . . . . . . . . . . . . 67
Table 20.0 File extensions of files downloaded from the HFR5-V . . . . . . . . . . . . . . . 67
Table 21.0 File extensions of files downloaded from the HFR5-D . . . . . . . . . . . . . . . 67
2.0 Introduction
The Handheld Multi-Purpose Interface (HHMPI) is a portable instrument for downloading
data from a Flight Data Recorder (FDR) and audio from a Cockpit Voice Recorder (CVR). It
6
Handheld Multi-Purpose Interface (HHMPI)
Introduction
is connected to the recorder via an interface cable which identifies the attached recorder
type. The downloaded data is stored in one of the following memory options: internal
memory, USB flash drive, Compact Flash card, SD card, or optional PCMCIA card.
Cancel / exit 4.
7
FDS40-0301
Introduction
8
Handheld Multi-Purpose Interface (HHMPI)
Introduction
9
FDS40-0301
Introduction
Applicable
Part number Description mod status
DF136 Quick reference guide, HHMPI All
FDS40-0107 (FDS400-107) Cable USB, HHMPI to PC All
FDS40-0301 (FDS400-301) HHMPI Mod 5
FDS40-0301 (FDS400-301) HHMPI with internal battery Mod 5, 6
FDS40-0301 (FDS400-301) HHMPI with external battery and PCMCIA card Mod 1, 5
FDS40-0302 (FDS400-302) USB flash drive (2GB) All
FDS40-0303 (FDS400-303) Compact flash card, HHMPI Option - all
FDS40-0304 (FDS400-304) SD card, HHMPI Option - all
FDS40-0310 HHMPI - Airbus approved model Mod 5, 6, 7
FDS40-0321 (FDS400-321) Carry case, yellow All except Mod 1
FDS40-0322 (FDS400-322) Power adapter kit, global, charger for internal Mod 6
battery
FDS40-0334 (FDS400-334) Carry case, black Mod 1
FDS40-0373 (FDS400-373) Docking cradle Mod 7
10
Handheld Multi-Purpose Interface (HHMPI)
Introduction
2.3 Accessories
Table 4.0 Interface cables and software options
11
FDS40-0301
Introduction
2.4 Specifications
Table 5.0 Specifications HHMPI Mod 5 (no battery)
Parameter
Weight HHMPI: 330 g
HHMPI kit: 3 kg (see Figure 6.0, ”HHMPI kit”, on page 10)
Shipping: 4 kg
Dimensions: L x W HHMPI: 145 x 95 x 35 mm
xH HHMPI kit: 365 x 270 x 135 mm
Power USB or FDR/CVR interface cable
Environmental IP-40
protection
Temperature Operating: -20°C to +60°C
Certification FCC Part 15 Subpart B, July 2008
CE
ANSI C63.4-2003 EN55022: 2006 (CISPR22: 2005, modified)
AS/NZS CISPR22: 2006 (CISPR22: 2006)
EN55024: 1998 Amendment 1: 2001 Amendment 2: 2003
CISPR24: 1997 MODIFIED Amendment 1: 2001 Amendment 2: 2002
Data view ARINC 717 for all recorders
ARINC 429 standard
ARINC 429 periodic
Data Link Rate (DLR)
Data view formats Binary
Octal
Decimal
Hexadecimal
Memory sup- Internal
ported SD card
CF card
USB flash drive
Communications USB v2.0 to PC
Ethernet RJ-45 to network
Ethernet via recorder interface to recorder
RS-422 via recorder interface to recorder
Wireless 802.11g capability via optional USB key
Parameter
Weight HHMPI: 495 g
HHMPI kit: 3.2 kg see (Figure 6.0, ”HHMPI kit”, on page 10)
Shipping: 4.2 kg
Dimensions: L x W HHMPI: 145 x 95 x 46 mm
xH HHMPI kit: 365 x 270 x 135 mm
Power USB or FDR/CVR interface cable
Internal Lithium Ion battery
Environmental IP-40
protection
Temperature Operating: 0°C to +60°C
12
Handheld Multi-Purpose Interface (HHMPI)
Getting started
Parameter
Certification FCC Part 15 Subpart B, July 2008
CE
ANSI C63.4-2003 EN55022: 2006 (CISPR22: 2005, modified)
AS/NZS CISPR22: 2006 (CISPR22: 2006)
EN55024: 1998 Amendment 1: 2001 Amendment 2: 2003
CISPR24: 1997 MODIFIED Amendment 1: 2001 Amendment 2: 2002
Data view ARINC 717 for all recorders
ARINC 429 standard
ARINC 429 periodic
Data Link Rate (DLR)
Data view formats Binary
Octal
Decimal
Hexadecimal
Memory sup- Internal
ported SD card
CF card
USB flash drive
PCMCIA card (ATA flash type only)
Communications USB v2.0 to PC
Ethernet RJ-45 to network
Ethernet via recorder interface to recorder
RS-422 via recorder interface to recorder
Wireless 802.11g capability via optional USB key
3.1 Terminology used In this manual the hardware buttons on the HHMPI are referred to as the left, right, up,
in this manual down, OK, or cancel buttons. See Figure 1.0, ”HHMPI front view”, on page 7 for the loca-
tions of these buttons on the HHMPI.
In this manual you may also see information of special importance in the form of tips and
notes.
A note with the heading “Note” indicates neutral or positive information that emphasizes
or supplements important points in this manual. For example:
13
FDS40-0301
Getting started
A tip is a type of note that helps you apply the techniques and procedures described in
this manual. A tip may suggests an alternative method of completing a task—tips are not
essential to the basic understanding of this manual. For example:
Tip You can also use these steps to copy an aircraft definition file.
An important note provides information that is essential to the completion of a task. You
can disregard information in a note and still complete a task, but you should not disre-
gard an important note. For example:
A caution is a type of note that advises you that failure to take or avoid a specific action
could result in damage or loss of data. For example:
A menu sequence shows you how to open a series of menus. For example:
▼▲ Main Menu >Device Configuration > Settings Profile > Save Aircraft >
USB Flash Drive
3.2 Using the HHMPI To download data from a Flight Data Recorder (FDR) or Cockpit Voice Recorder (CVR), you
need the following equipment:
The HHMPI kit, see Figure 6.0, ”HHMPI kit”, on page 10.
An interface cable for the specific recorder you want to download data from, see
Table 4.0, “Interface cables and software options,” on page 11.
14
Handheld Multi-Purpose Interface (HHMPI)
Getting started
15
FDS40-0301
Getting started
Charge battery powered HHMPI devices for 12 hours before first use. Charging is indi-
cated by a blue battery icon found in the status bar of the display. Full charge is indicated
by a green four bar battery icon. When charging is required, this battery icon turns red.
You can use the HHMPI when it is charging, however this increases the charging time.
HHMPI devices with Mod 7 can also be charged by a power adapter through the HHMPI
docking cradle (P/N: FDS40-0373).
16
Handheld Multi-Purpose Interface (HHMPI)
Getting started
Flight Data Systems recommends using the HHMPI Cradle for the following reasons:
The cradle provides direct current (DC) charging which extends battery life by avoid-
ing trickle charging.
The transfer of files from the HHMPI to the PC is stable and easy to operate when
docked.
Auto-sync and transfer files from the unit to a nominated FTP server via Ethernet con-
nection.
Configure the unit in the web interface using the Ethernet connection on the cradle.
To turn on a battery powered HHMPI, press cancel or OK for 2–3 seconds until the unit
beeps.
Once turned on, the start-up process begins and the power-on self-test is carried out. If
connected, the interface cable is detected automatically, and correct connection to the
flight data recorder is indicated by a blue aircraft icon found in the status bar of the dis-
play. See Figure 9.0, ”HHMPI power-on sequence”, on page 17.
To turn off the HHMPI, press cancel until the Confirm Power Off alert is displayed, and
then press OK to confirm.
17
FDS40-0301
Getting started
3.3 Shortcuts Shortcuts are used to provide user’s with a quick path to commonly used functions. There
are four user defined shortcut buttons.
▼▲ Main Menu > Device Configuration > Shortcut Keys > Shortcut n
The HHMPI displays the shortcut keys following the start-up and self-test. The shortcut
keys default to the following functions:
Select Aircraft
FDR All
FDR Since Last
Upload File (FTP)
3.4 Menu structure The HHMPI is controlled by a menu system. The four arrow buttons are used to navigate
the menu system. Generally, the right button is used to enter menus and the OK button
is used to confirm selections.
Tip To return to the Main menu from any other menu, press left
repeatedly.
3.5 HHMPI The HHMPI can be configured via a web interface, or directly on the unit. Using the web
configuration interface is the easiest way to set up the HHMPI, see Section 5.4.1, ”Changing the HHMPI
configuration via the web interface” on page 41.
Set the brightness of the display, 1 is minimum brightness and 10 is maximum brightness.
Set the preferred memory to download or file transfer by selecting one of the following:
18
Handheld Multi-Purpose Interface (HHMPI)
Getting started
Ask for device - Prompts the user to specify a device for download or file transfer.
Priority list - Prioritize memory devices based on customised preference.
User Specified Device - Set default memory device for storage and file transfer.
When connecting the HHMPI to a network connection via an Ethernet cable, setup IP,
DHCP and FTP settings necessary for network operation. See Section 4.7, ”Network oper-
ations” on page 35.
Set or edit aircraft tail numbers. See Section 4.2, ”Aircraft lists” on page 20.
Set access to the menus and settings of the HHMPI by using password access by select-
ing the following:
Restrict Configuration - Restrict modification of any HHMPI settings.
Restrict Menus - Only allow access to previously configured shortcut keys.
Set the global live data settings to be used in the live data view from, some of these
options may only be available for the L-3 Communications SRVIVR™ interface:
ARINC 717
ARINC 429. Standard or periodic.
DLR Settings. Select the data display format and data word description.
Set shortcut keys to change by selecting one of the options from the menu.
Save or load the device configuration to a file, or reset the configuration to the factory
default settings:
19
FDS40-0301
Operation
Load Settings
Save Settings
Reset Configuration
3.6 Information All the information about the HHMPI feature set, supported recorder types and the oper-
ating system version is found in the Information menu. This information may be useful
for troubleshooting, see Section 7.0, ”Troubleshooting” on page 46.
To access the HHMPI information, from the Main Menu press down until you reach the
Information command, and then press OK. The information in the Asset., Company and
Contact fields can be changed via the web interface, see Section 5.4.1, ”Changing the
HHMPI configuration via the web interface” on page 41. The remaining fields are only
configurable by Flight Data Systems.
4.0 Operation
4.1 Download file Files downloaded from a recorder to the HHMPI follow a standard naming convention,
name configured by the Filename Style command on the Settings menu. The naming conven-
tion is: _[aircraft tail number]_[date[_time]]_download type.ext
For example:
_20101010_1204_FDR_5_MINUTES.fdr
_VHFDS_101_20101010_1204_FDR_ALL.dlu
_VHFDS_101_20101010_1204_CVR_ALL.cvr
Note The file extension can vary according to the recorder type and
download mode.
The date and time string use the time format already configured in
the HHMPI.
Dates and time stamps are stripped to remove slashes and colons.
4.2 Aircraft lists Stored in the HHMPI as a comma separated variable file, the Aircraft List contains a list of
all aircraft in the fleet. Using an Aircraft List makes it easier to assign tail numbers to
operational downloads, it also makes the file names more readable.
20
Handheld Multi-Purpose Interface (HHMPI)
Operation
Important The file must be named aircraft.csv and the data fields
must be separated by a comma with each record separated by a car-
riage return (ASCII CR-LF).
Save or export the file to a USB flash drive as aircraft.csv. If an Aircraft List is not present,
data file names will default to _[aircraft tail number]_[date[_time]]_download type.ext.
▼▲ Main Menu > Device Configuration > Settings Profile > Load Aircraft
To transfer the Aircraft List to the HHMPI, insert the USB flash drive containing the file
named aircraft.csv into the USB port on top of the HHMPI.
1. From the Main Menu, press down until you reach the Device Configuration com-
mand, and then press right.
2. Press down until you reach the Settings Profile command, and then press right.
3. Press down until you reach the Load Aircraft command, and then press right.
4. Select where the file named aircraft.csv is located, and then press right.
21
FDS40-0301
Operation
▼▲ Main Menu > Device Configuration > Aircraft Settings > Add Aircraft
To create, or add to, the Aircraft List on the HHMPI, from the Add Aircraft menu:
1. Press down until you reach the Set Model command, and then press right.
2. Press up to enter the alphabetical grid, and then press the up, down, left and right
buttons to enter data.
3. When complete, press cancel to exit the alphabetical grid.
4. Press OK to confirm your selection.
5. Repeat steps 1 to 4 for Set Tail.
6. Press down until you reach the Add command, and then press right to confirm.
7. Press OK to confirm your selection.
To add additional aircraft, repeat steps 1 to 6 for each aircraft. See Section Figure 11.0,
”Adding aircraft to the Aircraft List on the HHMPI” on page 22.
▼▲ Main Menu > Device Configuration > Aircraft Settings > Delete Aircraft
To delete an aircraft from the Aircraft list on the HHMPI, from the Device Configuration
menu:
22
Handheld Multi-Purpose Interface (HHMPI)
Operation
1. Press down until you reach the Aircraft Settings command, and then press right.
2. Press down until you reach the Delete Aircraft command, and then press right to
select the aircraft you want to delete.
3. Press OK to confirm the deletion.
Selected aircraft remain in the list but are marked by a red X.
4.2.7 Saving the Aircraft list to the USB flash drive on the HHMPI
▼▲ Main Menu > Device Configuration > Settings Profile > Save Aircraft
To save the Aircraft List to a USB flash drive, insert a USB flash drive into the USB port on
the top of the HHMPI, and from the Device Configuration menu:
1. Press down until you reach the Settings Profile command, and then press right.
2. Press down until you reach the Save Aircraft command, and then press right to save
onto USB Flash Drive.
Important The Aircraft List is saved to the USB flash drive as air-
craft.csv.bkp. To transfer this file to the HHMPI again, it must be
renamed aircraft.csv.
Tip The saved aircraft.csv file can be used as a template to add more
aircraft or aircraft definition files (databases) to the Aircraft List.
4.2.8 Deleting all aircraft from the Aircraft list on the HHMPI
▼▲ Main Menu > Device Configuration > Aircraft Settings > Erase All Air-
craft
By selecting this option all the aircraft models and tail numbers in the Aircraft List will be
removed from the HHMPI. Press OK to confirm or cancel to cancel this operation.
▼▲ Main Menu > Device Configuration > Aircraft Settings > Prompt for Tail
No.
Enabling the Prompt for Tail No. command forces a user to assign a tail number to an
operational download. This ensures that a download file name contains the aircraft tail
number, which may help in traceability of data and further analysis.
23
FDS40-0301
Operation
4.3 Downloading flight The HHMPI can be used to download recorded data from the FDR and voice from the
data CVR. It is connected to the recorder via an interface cable which identifies the attached
recorder type. When downloading flight data, the following procedure is generally used:
Create the Aircraft List, if required. See Section 4.2, ”Aircraft lists” on page 20. The Air-
craft List may be created and stored in a HHMPI to populate the aircraft tail variable
in the data file name. The manufacturer and model variables are not used in the data
file name.
Select the aircraft, model and tail number from the Aircraft List.
Note If this step is omitted the file name will only include the time
stamp. If you want to force users to assign a tail number before an
operational download enable the Prompt for Tail No. command.
See Section 4.2.9, ”Prompt for Tail No.” on page 23.
4.3.1 Downloading recorded data from the FDR to a USB flash drive
To download flight data from the FDR to a USB flash drive:
1. Connect the HHMPI to the FDR with an interface cable, see Figure 7.0, ”Connecting
the HHMPI to the FDR or CVR”, on page 15.
2. Turn on the HHMPI and FDR. Once turned on, the start-up process begins and the
power-on self-test is carried out. If connected to the HHMPI, the interface cable is
detected automatically, and correct connection to the FDR is indicated by a blue air-
craft icon found in the status bar of the display.
3. Plug the USB flash drive into the USB port on the top of the HHMPI. An alert, USB
Drive Inserted, should appear momentarily.
An orange USB flash drive icon will also appear in the status bar indicating the HHMPI
is ready to write to the USB flash drive.
4. From the Main Menu, press down until you reach the Download Operations com-
mand, and then press right. Then press down until you reach the data you want to
24
Handheld Multi-Purpose Interface (HHMPI)
Operation
download, and then press right. There are usually four download commands,
depending on the type of recorder:
FDR All, downloads all the available data.
FDR Since Last, downloads all the data recorded since the last download.
FDR Mark, downloads the data from a pre-recorded marker.
FDR Time, downloads data for a specified time, for example, 20 minutes will
download the last 20 minutes recorded.
5. If an external storage device, like a USB flash drive, is plugged into the HHMPI, you
may now select to store the data onto this device. To start downloading the data,
press right.
The display will now show the download progress. When the download completes,
press OK.
Tip You can set the preference of external storage devices from the
Memory Settings menu. For example, prioritise the USB flash drive,
when present, over the HHMPI internal memory.
After selecting CVR download, the De-multiplex to Wave option will appear. Press the
OK button to decompress the raw CVR file to waveform files. Generally there will a wave-
form for each channel recorded on the CVR. If you do not want to decompress the raw
25
FDS40-0301
Operation
CVR file to waveform files, press the cancel button. See Section Figure 14.0, ”Download-
ing and decompressing CVR data” on page 26.
After the download completes, the raw CVR file and the waveform files from each chan-
nel will be available on the nominated storage device. These files can be transferred to a
computer or another device where they can be replayed. A codec may need to be
installed, this is included as part of the HHMPI kit.
From the home screen, press right to access the Main Menu, scroll down to the Utilities
command, and then press OK.
Note To decompress CVR data away from the aircraft, the de-multi-
plexing feature needs to be enabled on the HHMPI. Contact Flight
Data Systems for more information about this feature. Decompres-
sion of CVR data away from the aircraft also only applies to Honey-
well CVRs.
On the Decompress DLU command, press OK, and then select the raw .dlu file to
decompress and the decompression process will begin.
26
Handheld Multi-Purpose Interface (HHMPI)
Operation
Figure 15.0 Decompressing Honeywell CVR file away from the aircraft
After the decompression completes, the raw CVR file and the waveform files from each
channel will be available on the nominated storage device. These files can be transferred
to a computer or another device where they can be replayed. A codec may need to be
installed, this is included as part of the HHMPI kit.
4.3.4.1 Using the Honeywell SSCVR Rack Adaptor Cable part number
FDS40-0215 (FDS400-215) – (For Honeywell SSCVR part numbers 980-6020-
XX & 980-6022-XX only)
Firstly ensuring no power is provided to the CVR, un-rack the CVR.
Connect the Honeywell SSCVR Rack Adaptor into the rear connector of the CVR and
carefully re-rack the CVR.
Connect the HHMPI interface cable from the Rack Adaptor to the HHMPI.
Power the CVR on the aircraft & start up the HHMPI. With the CVR record mode now
disabled ensure the aircraft icon in the status bar of the HHMPI’s display turns blue
and begin a CVR download.
After the download has completed, remove power from the CVR & remove the Hon-
eywell SSCVR Rack Adaptor Cable from the aircraft in the reverse order to the fitment.
4.3.4.2 Using the ARINC 757 CVR Rack Adaptor part number FDS40-0247
(FDS400-247)
Firstly ensuring no power is provided to the CVR, disconnect the aircraft power from
the back of the CVR while in the rack.
Using the HHMPI interface cable for the CVR - insert this into the CVR front GSE con-
nector and then into the HHMPI. Power the CVR and power the HHMPI. Ensure the
blue plane appears in the HHMPI and begin a CVR download at the aircraft.
After the download has completed ensure the ARINC 757 CVR Rack Adaptor is
removed from the aircraft.
27
FDS40-0301
Operation
4.4 Viewing live flight The HHMPI can be used to monitor live ARINC 717 data from the aircraft. The Live Data
data View can display data from the FDR in five formats:
Binary (Base 2)
Octal (Base 8)
Decimal (Base 10)
Hexadecimal (Base 16)
Engineering units (EU)
The Live Data View display options are accessible via the shortcut buttons 1–4.
Note These menu items will only be visible where they are supported
by the connected FDR/CVFDR.
▼▲ Main Menu > Live Data View > View Live FDR Data > View ARINC 717
Data
3. From the Main menu, press down until you reach the Live Data View command, and
then press right. Then press down until you reach the View Live FDR Data com-
mand, and then press right to View ARINC 717 Data. See Figure 16.0, ”Viewing live
data”, on page 29.
4. Wait until the HHMPI synchronises with the FDR, while synchronising, UNKNOWN is
displayed on the screen. After synchronising, you can view live data from the aircraft
parameters.
For more information about formatting and displaying data on the HHMPI, see
Section 4.4.2, ”Adjusting ARINC 717 settings” on page 29 and Section 4.4.3, ”Chang-
ing the display format” on page 30.
28
Handheld Multi-Purpose Interface (HHMPI)
Operation
▼▲ Main Menu > Live Data View > View Live FDR Data > View ARINC 717
Data
To access the ARINC 717 settings, press right on a selected parameter / word cell. The
following options will be displayed:
Word Offset, selects the current word from 1 to 2048. To change the Word Offset
number, use the up, down, left and right buttons, and then press OK to confirm your
selection.
Sub-frame, selects the sub-frame to view from 1 to 4, or ALL. ALL is the default value
for this setting. To change the sub-frame, use the up and down buttons, and then
press right to confirm your selection.
Viewing Mode, provides the option to view live data in the following formats: Binary-
Octal, Binary-Decimal and Binary-Hexadecimal. To change the viewing mode, use the
up and down buttons, and then press right to confirm your selection.
MSB (Most Significant Bit), hides all binary bits in the word before the MSB. To
change the MSB, use the up and down buttons, and then press right to confirm your
selection.
LSB (Least Significant Bit), hides all binary bits in the word after the LSB. To change
the LSB, use the up and down buttons, and then press right to confirm your selec-
tion.
29
FDS40-0301
Operation
Parameters for each displayed Live Data Word-Offset can be modified. See Section 4.4.3,
”Changing the display format” on page 30.
Main Menu > Live Data View > View Live FDR Data > View ARINC 717
Data > Up | Down | Left | Right
30
Handheld Multi-Purpose Interface (HHMPI)
Operation
4.5 Viewing live flight To view the live flight data in Engineering Units (EU Mode), you must associate an Aircraft
data in engineering Definition file with an aircraft. The Aircraft Definition file is exported from STARS with the
units extension .sdf. You will need to transfer this file to the HHMPI either through a direct USB
connection, where the HHMPI will be picked up as an external storage device, or via one
of the removable memory options such as an SD memory card, or USB flash drive.
▼▲ Main Menu > Device Configuration > Aircraft Settings > Assign Data-
base > Aircraft Tail Number
31
FDS40-0301
Operation
▼▲ Parameter / Word Cell > Select Parameter > First Letter of Parameter >
Parameter > OK
After assigning an Aircraft Definition file to an aircraft, see Section 4.5.1, ”Assigning an
Aircraft Definition file to an aircraft” on page 31, to view the live flight data in Engineer-
ing Units:
1. To view live flight data in Engineering Units, you must select an aircraft which already
has an Aircraft Definition file (database) assigned to it. To select an aircraft, from the
Main Menu, press right on the Select Aircraft command, and then press right on
the aircraft you want to view the live flight data from. The selected tail number will
appear on the shortcut screen. See Figure 20.0, ”Selected tail number on the shortcut
screen”, on page 32.
2. Follow the procedure in Section 4.4, ”Viewing live flight data” on page 28 and wait
until the HHMPI synchronises with the FDR, while synchronising, UNKNOWN is dis-
played on the screen.
3. Press a shortcut button to select a parameter / word cell.
4. Press right to display the ARINC 717 settings menu.
5. Enable the EU Mode radio button, then press down until you reach the Select
Parameter command, and then press right. An alphabetical list will be displayed, see
Figure 22.0, ”Accessing aircraft parameters alphabetically”, on page 33.
Note The EU Mode radio button will only appear if an aircraft had
been selected that has an Aircraft Definition file (database) assigned
to it.
32
Handheld Multi-Purpose Interface (HHMPI)
Operation
6. Press right on the first letter of the parameter you want to look at, and then press
right again. This command will display all the parameters starting with the letter you
have selected.
7. Press OK twice to return to the ARINC 717 view. The selected parameter / word cell
will now display live data according to the algorithm in the configured database.
As in the raw data view, up to four parameters / word cells can be displayed and con-
figured independently. Values will update once per sub-frame and SAMPLING will
flash green and white for each update. See Section Figure 23.0, ”Four parameters
populated with Engineering Units” on page 34.
33
FDS40-0301
Operation
4.6 File transfer 4.6.1 File transfer between HHMPI storage locations
operations
▼▲ Main Menu > Storage Operations > Select Files | Select All Files
The general method of transferring files between connected memory devices is:
From the Main menu press the down button until you reach the Storage Operations
command, and then press the right button on either the Select Files or Select All
Files command, and then select the preferred memory device.
Select the file(s) by pressing the right button.
Press the left button to return to the Storage Operations menu.
Select Copy Files then Select Memory Device and press the right button to confirm.
To delete, select Delete Files.
To format a memory device, from the Storage Operations menu, press right on the For-
mat command, and then select the memory device you want to format.
▼▲ Main Menu > Storage Operations > Format > Select Memory Device
34
Handheld Multi-Purpose Interface (HHMPI)
Operation
4.7 Network The HHMPI is capable of transferring files over a network using FTP and also for device
operations configuration in any web browser.
▼▲ Main Menu > Device Configuration > Network Settings > Wired Set-
tings
OR
Manually configure the IP address by pressing right on the Manual Configure com-
mand.
Use the up button to set the IP Address, Netmask and Gateway.
Press the OK button.
See Figure 24.0, ”DHCP or manual IP configuration”, on page 36.
▼▲ Main Menu > Network Operations > View Wired Address > Adaptor:
eth0
35
FDS40-0301
Configuring an FTP connection
5.1 Adding a new FTP To add a new FTP server from the HHMPI, from the Main menu:
server from the HHMPI
▼▲ Main Menu > Device Configuration > Network Settings > FTP Servers >
Add FTP Server
1. Press down until you reach the Device Configuration command, and then press
right. Then press down until you reach the Network Settings command, and then
press right. Then press down until you reach the FTP Servers command, and then
press right. See Figure 25.0, ”Setting up the FTP client”, on page 37.
2. Ensure you have access to the FTP server and the FTP server settings, including the IP
address, username, password, and the encryption type. This FTP server information is
usually available from your IT department.
3. From the FTP Servers menu, press down until you reach the Add FTP Server com-
mand, and then press right. To add an FTP server name, press up to enter the name
from the alphabet grid with the arrow buttons, pressing OK between each letter.
36
Handheld Multi-Purpose Interface (HHMPI)
Configuring an FTP connection
When complete, press cancel to exit the alphabet grid, and then press OK to confirm
your selected FTP server name.
Tip The FTP server name is not used in connection to the FTP server,
you can give the FTP server any name.
5.2 Configuring an To configure an existing FTP server, from the FTP Servers menu, press down until you
existing FTP server reach the FTP server name you want to configure, and then press right. Then do one of
from the HHMPI the following:
1. To save an IP Address, press right on the FTP IP Address command. To enter the IP
Address, press up or down on each number, and then press OK to confirm your
selection.
2. To save an FTP Type, press right on the FTP Type command, and then press down
until you reach the FTP type you want, and then press right. The HHMPI supports
three FTP types:
FTP (port 21), unsecured transmission on port 21
FTP over SSL, secured transmission that encrypts the username and pass-
word, and content with SSL
37
FDS40-0301
Configuring an FTP connection
FTP over SSH, secured transmission that encrypts the username and pass-
word, and content with SSH
3. To save an FTP username, press right on the FTP Login command, and then press up
to enter the username from the alphabet grid with the arrow buttons, pressing OK
between each letter. When complete, press cancel to exit the alphabet grid, and then
press OK to confirm the username.
4. To save an FTP password, press right on the FTP Password command, and then press
up to enter the password from the alphabet grid with the arrow buttons, pressing OK
between each letter. When complete, press cancel to exit the alphabet grid, and then
press OK to confirm the password.
5. To save a Remote Path, press right on the Remote Path command, and then press up
to enter the remote path from the alphabet grid with the arrow buttons, pressing OK
between each letter. When complete, press cancel to exit the alphabet grid, and then
press OK to confirm the remote path.
The Remote Path field controls which folder the file is uploaded to on the FTP server.
Depending on the FTP server configuration, this may be an optional field. Leaving the
remote path blank means the file will be uploaded to the default folder your FTP
account logs into.
Note Select the Use Temporary File check box if the HHMPI is to
use a temporary file when uploading. When the upload is complete,
this temporary file is renamed to the final file name. This is useful for
ensuring that remote systems do not read a partially uploaded file.
38
Handheld Multi-Purpose Interface (HHMPI)
Configuring an FTP connection
5.3 Testing an FTP To test an FTP connection, from the FTP Servers menu, press down until you reach the
server from the HHMPI FTP server name you want to test, and then press right. Then press down until you reach
the FTP Test command, and then press right. See Figure 27.0, ”Login, password, remote
path and FTP test”, on page 39.
5.4 Setting up an FTP You can configure the HHMPI through the web interface in any web-browser. Using the
connection from the web interface is the easiest way to configure the HHMPI.
web interface
▼▲ Main Menu > Network Operations > View Wired Address
39
FDS40-0301
Configuring an FTP connection
1. Open a web-browser such as Mozilla Firefox or Google Chrome and type the wired IP
address into the browser’s address bar.
2. Login to the HHMPI web interface using the default username and password:
Username: admin
Password: admin
See Figure 29.0, ”Web interface login”, on page 40.
40
Handheld Multi-Purpose Interface (HHMPI)
Configuring an FTP connection
41
FDS40-0301
Configuring an FTP connection
42
Handheld Multi-Purpose Interface (HHMPI)
Configuring an FTP connection
Important The Aircraft List is saved to the USB flash drive as air-
craft.csv.bkp. To transfer this file to the HHMPI again, it must be
renamed aircraft.csv.
43
FDS40-0301
Wirelessly uploading files from the HHMPI to a server
6.1 Setting up a Some HHMPI models, when in range of a wireless network, support the wireless upload
wireless network of files from the HHMPI to a server. This upload method uses a USB wireless network
connection adapter plugged into the USB port on top of the HHMPI.
Note The HHMPI must include the wireless option which enables
support for the wireless upload of files from the HHMPI to a server.
▼▲ Main Menu > Device Configuration > Network Settings > Enable Net-
working > Wireless Network
44
Handheld Multi-Purpose Interface (HHMPI)
Wirelessly uploading files from the HHMPI to a server
2. Plug the USB wireless network adapter into the USB port on the top of the HHMPI. An
alert Configuring Wi-Fi - Please Wait should appear momentarily.
A white antenna icon will also appear in the status bar indicating the HHMPI is ready
to connect to wireless networks in range.
3. From the Main menu, press down until you reach the Device Configuration com-
mand, and then press right. Then press down until you reach the Network Settings
command, and then press right. See Figure 35.0, ”Connecting to a wireless network”,
on page 45.
4. Press right to select the Enable Networking check box.
5. Press down until you reach Wireless Network, and then press right to Scan for wire-
less networks in range, or add a wireless network manually with an ESSID.
To select an encryption type and enter a key, from the Wireless Settings menu:
1. Press down until you reach Encryption Type command, and then press right to
select the encryption type from the following commands: WEP, WPA1, and WPA2.
2. Press left to return to the Wireless Settings menu, then press down to select the
Key command, and then press right to enter the key.
3. Press up to enter the key from the alphabet grid with the arrow buttons, pressing OK
between each letter. When you are finished, press cancel and then OK to return to
the Wireless Settings menu.
If you have successfully connected to a wireless network, the white antenna icon in
the status bar will change to a green four bar signal strength icon. If this signal
45
FDS40-0301
Troubleshooting
strength icon does not appear, you are not connected to a wireless network and may
need to contact your IT department.
To save the encryption type and key, from the Device Configuration menu:
Press down until you reach the Save Settings command, and then press right.
Figure 36.0 Configuring security settings like the encryption type and key
7.0 Troubleshooting
To troubleshoot the HHMPI, first try the following steps:
Turn the HHMPI on and off by following the steps in Section 3.2.4, ”Turning on the
HHMPI and self-test” on page 17.
46
Handheld Multi-Purpose Interface (HHMPI)
Troubleshooting
If this did not work, try connecting the HHMPI to a power adapter and plug the
power adapter into an electrical outlet, or connect the HHMPI to your computer.
Make sure the computer is turned on and isn’t set to go to sleep.
If this does not work, try resetting the HHMPI by following the steps in Section 3.2.5,
”Reset operation” on page 17.
Retry the HHMPI with a different recorder if possible.
Restart the recorder if possible and try again.
If these steps do not solve your problem, below is a list of potential problems and solu-
tions. If your problem is not listed, use the Report Error menu option (if possible) on the
HHMPI, and send the generated file to support@flightdata.aero with a description of the
problem, the serial number of the HHMPI, and the part numbers of recorders you are try-
ing to interface with (if applicable).
Issue Solution
HHMPI does not power up. Battery requires charge, for battery equipped units.
47
FDS40-0301
Troubleshooting
Issue Solution
Unable to download file from Select a memory device, see Section 3.5.3, ”Memory Settings”
recorder on page 18.
Ensure that the HHMPI is configured for the recorder, see Sys-
tem Information in Section 5.4.1, ”Changing the HHMPI config-
uration via the web interface” on page 41.
Check the aircraft interface cable for any debris that could be
causing connection issues.
A message is displayed indicat- Cancel and restart the download.
ing that the download has
stopped or stalled.
Cannot see live data in the live Ensure correct connection to the recorder. Connection is indi-
data view, only see unknown val- cated by a blue aircraft icon found in the status bar of the dis-
ues. play.
48
Handheld Multi-Purpose Interface (HHMPI)
Troubleshooting
Issue Solution
Cannot send files from the Confirm the FTP settings are correct, see Section 5.0, ”Configur-
HHMPI to an FTP server via a ing an FTP connection” on page 36.
wired network connection
Ensure that an Ethernet cable is connected, and ensure correct
connection to the recorder. Connection is indicated by a yellow
network connection icon found in the status bar of the display.
See Section 3.5.4, ”Network Settings” on page 19.
Try loading the file through the web interface, see Section 5.4.1,
”Changing the HHMPI configuration via the web interface” on
page 41.
Cannot copy file from external Ensure that the external memory device is connected. Connec-
memory device. tion is indicated by an orange USB flash drive icon found in the
status bar of the display.
Check that the file is selected before attempting to copy the file.
Check that the external memory device is not full.
Cannot delete file from media Ensure that the external memory device is connected. Connec-
storage device. tion is indicated by an orange USB flash drive icon found in the
status bar of the display.
49
FDS40-0301
FA2100, FA2200 and FA2300 Interface Supplement
Issue Solution
“Unsupported Cable Detected” Ensure that the aircraft interface cable is correctly inserted.
Ensure that the HHMPI is configured for the recorder, see Sys-
tem Information in Section 5.4.1, ”Changing the HHMPI config-
uration via the web interface” on page 41.
Check the aircraft interface cable for any debris that could be
causing connection issues.
“Mount Error” Ensure that the external memory device is not corrupt or dam-
aged in anyway.
50
Handheld Multi-Purpose Interface (HHMPI)
FA2100, FA2200 and FA2300 Interface Supplement
8.5 FDR or CVR Fault The cockpit fault light can be forced on or off using the left and right buttons.
Output
8.8 Dump Fault Log Saves the fault log to selected memory. See Figure 37.0, ”FA2100 Recorder Operations -
Dump Debug Trace”, on page 51.
8.9 Dump Debug Trace This function dumps the running debug stream from an L3 FA2100 recorder to a file on
the HHMPI. This file is a text file readable in any text editor.
51
FDS40-0301
FA2100, FA2200 and FA2300 Interface Supplement
8.10 Memory Marker Set a new FDR memory marker. The next marker will be chosen in the range 1-15, when
all the markers are set, the marker count returns to 1.
8.11 Audio Operations The FA5000/FA5001 audio can be both monitored in real time, and also play back previ-
ously recorded data. To listen to audio, plug headphones into the audio jack on the bot-
tom of the HHMPI, see Figure 3.0, ”HHMPI bottom view”, on page 8.
Press the up and down buttons to select which channel you want to listen to. Shortcut
button 2 increases the volume and shortcut button 3 decreases the volume. In playback
mode, the left and right buttons rewind or fast forward the current playback position.
See Figure 38.0, ”CVR Live Audio volume control”, on page 52.
8.12 Live Data View Real time ARINC-717 data can be monitored from the FA2100. See Section 4.4, ”Viewing
live flight data” on page 28.
8.13 Menu Tree The following menu items are enabled on connection to a FA5000/FA5001 recorder.
52
Handheld Multi-Purpose Interface (HHMPI)
SRVIVR™ Interface Supplement
53
FDS40-0301
SRVIVR™ Interface Supplement
See Figure 39.0, ”SRVIVR™ Download Operations”, on page 54 and Section 4.3, ”Down-
loading flight data” on page 24.
54
Handheld Multi-Purpose Interface (HHMPI)
SRVIVR™ Interface Supplement
9.3 Audio Operations The SRVIVR™™ audio can be monitored in real time. To listen to audio, plug headphones
into the audio jack on the bottom of the HHMPI, see Figure 3.0, ”HHMPI bottom view”,
on page 8.
Press the up and down buttons to select which channel you want to listen to. Shortcut
button 2 increases the volume and shortcut button 3 decreases the volume. See
Figure 45.0, ”CVR Live Audio volume control”, on page 60.
9.4 Live Data View Three streams of real time data can be monitored from the SRVIVR™:
Live ARINC-717, see Section 4.4, ”Viewing live flight data” on page 28.
Monitoring of Captain’s Clock on the ARINC-429 GMT BUS, both labels 125 and 150.
Monitoring of Rotor Frequency in Hz.
55
FDS40-0301
SRVIVR™ Interface Supplement
9.5 Menu Tree The following menu items are enabled on connection to a SRVIVR™ recorder.
56
Handheld Multi-Purpose Interface (HHMPI)
FA5000/FA5001 Interface Supplement
See Figure 42.0, ”FA5000/FA5001 Download Operations”, on page 58 and Section 4.3,
”Downloading flight data” on page 24.
FDR All - Retrieves all flight data from the recorder.
FDR Since Last - Retrieves only new flight data recorded since the last download oper-
ation was performed.
FDR Time - Retrieves the last specified duration of flight data.
FDR Mark - Retrieves all flight data newer than a specified memory mark.
CVR All - Retrieves all cockpit voice recordings from the recorder.
57
FDS40-0301
FA5000/FA5001 Interface Supplement
CVR Since Last - Retrieves only new cockpit voice recordings recorded since the last
download operation was performed.
CVR Time - Retrieves the last specified duration of cockpit voice recordings.
CVR Mark - Retrieves all cockpit voice recordings newer than a specified memory
mark.
DLR All - Retrieves all Datalink recordings from the recorder.
DLR Since Last - Retrieves only new Datalink recordings recorded since the last down-
load operation was performed.
DLR Mark - Retrieves all Datalink recordings newer than a specified memory mark.
58
Handheld Multi-Purpose Interface (HHMPI)
FA5000/FA5001 Interface Supplement
10.3 FDR The FDR configuration menu details information about the recorder such as part num-
Configuration bers and version numbers.
10.4 Audio Operations The FA5000/FA5001 audio can be both monitored in real time, and also play back previ-
ously recorded data. To listen to audio, plug headphones into the audio jack on the bot-
tom of the HHMPI, see Figure 3.0, ”HHMPI bottom view”, on page 8.
Press the up and down buttons to select which channel you want to listen to. Shortcut
button 2 increases the volume and shortcut button 3 decreases the volume. In playback
mode, the left and right buttons rewind or fast forward the current playback position.
See Figure 45.0, ”CVR Live Audio volume control”, on page 60.
59
FDS40-0301
FA5000/FA5001 Interface Supplement
10.5 Live Data View Three streams of real time data can be monitored from the FA5000/FA5001:
Live ARINC-717, see Section 4.4, ”Viewing live flight data” on page 28.
Monitoring of Captain’s Clock on the ARINC-429 GMT BUS, both labels 125 and 150.
Monitoring of Rotor Frequency in Hz.
10.6 Menu Tree The following menu items are enabled on connection to a FA5000/FA5001 recorder.
60
Handheld Multi-Purpose Interface (HHMPI)
FA5000/FA5001 Interface Supplement
61
FDS40-0301
A200S Interface Supplement
Table 13.0 File extensions of files downloaded from the L-3 A200S
12.1 Select Aircraft The Smiths VADR Select Aircraft menu is pre-installed with ARMY and RAAF models and
registration information. See Figure 4.2.5, ”Adding Entries to the HHMPI Aircraft File”, on
page 22 to add additional aircraft.
12.2 Download The Smiths VADR supports the following download options:
Operations FDR All - Retrieves all flight data from the recorder.
CVR All - Retrieves all cockpit voice recordings from the recorder.
Table 14.0 File extensions of files downloaded from the Smiths VADR
12.3 FDR The FDR configuration menu details information such as aircraft serial number, version
Configuration numbers (MP Software P/N and CP Software P/N), upload of Operational Flight Program
(OFP) and settings for the aircraft tail number. See Figure 46.0, ”VADR information”, on
page 63.
62
Handheld Multi-Purpose Interface (HHMPI)
SMITHS VADR Interface Supplement
Once complete return to the FDR Configuration and confirm the files are loaded in the
Information section. See Figure 47.0, ”Uploading OFP to the VADR from the HHMPI”, on
page 64.
63
FDS40-0301
Universal™ Interface Supplement
13.1 Download The Universal CVFDR supports the following download options:
Operations FDR All - Retrieves all flight data from the recorder.
FDR Time - Retrieves the last specified duration of flight data.
CVR All - Retrieves all cockpit voice recordings from the recorder.
CVR Time - Retrieves the last specified duration of cockpit voice recordings.
Table 15.0 File extensions of files downloaded from the Universal CVFDR
The cockpit voice data from the Universal CVFDR is downloaded as a waveform (one for
each channel) which can be played in most audio applications.
64
Handheld Multi-Purpose Interface (HHMPI)
B&D (Penny & Giles) 91005 series
65
FDS40-0301
Penny & Giles Multi-purpose flight recorder (MPFR) 051615 series
15.3 Menu Tree The following menu items are enabled on connection to a MPFR recorder.
66
Handheld Multi-Purpose Interface (HHMPI)
Lockheed L-209 (Plessey PV-1584)
67
FDS40-0301
Index
Index
A Power adapter 10
aircraft.csv 21, 49
Audio 7 R
Record of changes 5
B Report Error 47
Battery Fault Condition 49
S
C SCR500 11
Compact Flash card 7, 10 SD card 7, 10
Cursor keys 7 Smiths 62, 64
SRVIVR 11, 53
Stalled 48
D Stopped 48
Docking cradle 7, 10
T
E Troubleshooting 46
External battery 7
U
F Unsupported Cable Detected 50
F1000 11 Uploading files 46
FA2100 11, 52 USB flash drive 7, 10
FA2100 CVR 7 UV 49
FA2200 50
FA2300 50
FA500
V
FDR Fault 61 VADR 7, 62
FA5000 11, 57
CAM Audio Present and Sending W
Data 61 Wireless interface 11
CVR Fault 61
Datalink Data Received 61
FDR Input Data Lock 61
GMT Data Received 61
Latest CVR Marker 61
OMS Data Received 61
Rotor Data Received 61
FA5001 11, 57
I
Interface cable 11
Internal battery 7, 10
Introduction 6
L
List of figures 5
List of tables 6
M
MCR500 7, 11
Mount Error 50
P
PCMCIA card 7, 10
68
FDS40-0301