Lighting Catalogue © Nardeen 2017.

All rights
reserved for all countries.
No part of this work may

2017 be reproduced or utilized


in any means, including
photographic
0U[YVK\J[PVU ǛƸŲǍŽȚǜƵŲǍŽȚʇȚǛƉŮ

Founded in 1982, our company has left no issue in the light- έϭργ ϲϓ ϥϳΩέΎϧ
ing business without addressing it in depth. At Nardeen Light-
ing we are committed to our customers and we have focused ϕϭΫΑ ϙϠϬΗγϣϟ΍ ϊΗϣΗϭ ˬ ΕϻΎΟϣϟ΍ ΔϓΎϛ ϲϓ ϱΩϭόγϟ΍ ϕϭγϟ΍ έϭρΗ ϝυ ϲϓ
our corporate life on the quality of both our products and our .....ΕΎϣΩΧϟ΍ ϝοϓ΃ϭ ΓΩϭΟϟ΍ ΕΎΟέΩ ϰϠϋ΄Α ϪϛγϣΗϭ ˬίϳϣΗϣ ϝΎϋ
services. Although we manufacture a wide range of lighting
¿[tures to meet most e[pectations, we never say no to spe- ϰϟ· ΢ϣρΗ Δγγ΅ϣϛ ΓέΎϧϹ΍ ϡϟΎϋ ϲϓ ϡ 1982 ϡΎϋ ϥϳΩέΎϧ ΓΩϻϭ ΕϧΎϛ
cial requirements by Architects, Consultants and 6peci¿ers. ϡΎϋ ϲϓ ΕΩϏ ϰΗΣ ϯέΑϛϟ΍ ϑ΍ΩϫϷ΍ ϥϣ ΩϳΩόϟ΍ ϰϟ·ϭ έϭρΗϟ΍ ϥϣ έϳΛϛϟ΍
Customization is a must in our business, and our engineering ϼΛϣϣϭ ΔϘΛϠϟ Ύόοϭϣ Εϟ΍ί ϻϭ ΕϧΎϛ ΓΩϭΩΣϣ Δϳϟϭ΅γϣ Ε΍Ϋ Δϛέη ϡ1987
department is constantly developing and improving designs.
The keywords of our manufacturing strategy are: ρΎηϧ έλΗϘϳ ϡϟϭ ˬΔϛϠϣϣϟ΍ ϲϓ ΔϳϣϟΎόϟ΍ ΓέΎϧϹ΍ ΕϻΎϛϭ ϰϗέ΃ϭ έϬηϷ
Safety: Our models are built to meet National/International
ˬϯϭΗγϣϟ΍ Δόϳϓέϟ΍ ΎϬΗΎΟΗϧϣ Ω΍έϳΗγ΍ϭ ΔϳϣϟΎόϟ΍ ΕϻΎϛϭϟ΍ ϝϳΛϣΗ ϰϠϋ ϥϳΩέΎϧ
Standards. ϝϣόϟ΍ϭ ΓέΎϧϹ΍ ΓίϬΟ΃ Ω΍έϳΗγ΍ ϡΟΣ ϥϣ ϝϳϠϘΗϟ΍ ΔϳγΎγϷ΍ ΎϬϓ΍Ωϫ΃ ϥϣ ϥΎϛ ϝΑ
Quality: Our ¿[tures are tested at several steps of the manu- ΎϫΩϭϬΟ ΕέϣΛ΃ ϰΗΣ ˬ Ϫϟ ΕϧΎϛ ϱΫϟ΍ Ρϭϣρϟ΍ ϯϭΗγϣΑ ΎϳϠΣϣ ΎϬΟΎΗϧ΍ ϰϠϋ
facturing process.
Durability: We design for a long lasting product. ϰϠϋ ϡΧο ϊϧλϣ ΔϣΎϗΈΑ ΔϛϠϣϣϟ΍ ϲϓ έϭρΗϟ΍ Γέϳγϣ ΔΑϛ΍ϭϣϟ ΔϠλ΍ϭΗϣϟ΍
Product performance: To give more value to our customers. ΔϓΎϛΑ ΕϧγϳέϭϠϔϟ΍ ΓέΎϧ· Ε΍ΩΣϭ ϊϳϣΟ ΝΎΗϧϹ ϊΑέϣ έΗϣ ϑϟ΃ 25 ΔΣΎγϣ
With these four pillars - offering holistic lighting solutions and ΍Ϋϫ ˯Ύηϧ· ΦϳέΎΗ ϭϫ Ύοϳ΃ ϡ1987 ϡΎϋ ϥΎϛϭ .....ΎϬΗΎϳϭΗγϣ ϰϗέ΃ϭ ΎϫΎϳ΍ίϣ
a full customers service commitment - we are further consoli- ΩόΑ ΎϣΎϋ ΕΩϳ΍ίΗ ˬΎϳϭϧγ ΓΩΣϭ 75ˬ000 Ύϫέ΍ΩϘϣ ΔϳΟΎΗϧ· ΔϗΎρΑ ϊϧλϣϟ΍
dating our aim of lighting the way as your partner of choice.
It is the ability to offer perfect lighting solutions based on ad- Ϫϳϟ· ΕϠλϭΗ Ύϣ ΙΩΣ΃ ϕϓϭ ϊϧλΗ ΓΩΣϭ 2ˬ700ˬ000 ΕΣΑλ΃ ϰΗΣ ϡΎϋ
vanced technologies, competent system planning and intel- ΔϳΩϭόγϟ΍ ΔϳΑέόϟ΍ Δ΋ϳϬϟ΍ έϳϳΎόϣϭ ΕΎϔλ΍ϭϣϟ ΔϣΎΗ ΔϘΑΎρϣ ϊϣ ΓέΎϧϹ΍ ΔϳϧϘΗ
ligent lighting management that makes Nardeen your part-
ner of choice for professional lighting. Nardeen obtained in ϊϳϣΟ ϕϓ΍ϭΗϭ ˬΔϳϣϟΎόϟ΍ ΕΎϔλ΍ϭϣϟ΍ϭ (SASO) αϳϳΎϘϣϟ΍ϭ ΕΎϔλ΍ϭϣϠϟ
1999 the %S (N ISO 9001 certi¿cation that recognizes quality ˬΓέϭρΗϣϭ ΔϳϟΎϋ ΓΩϭΟΑϭ ΔλΎΧ ϭ΃ ΔϣΎϋ ϥϣ ΔϛϠϣϣϟ΍ ϲϓ ΓέΎϧϹ΍ ϊϳέΎηϣ
procedures, which are consistently aimed at improving cus-
tomer satisfaction by means of optimization of the company ΓΩϭΟϟ΍ ΓΩΎϬη ϰϠϋ ϡ1999 ϡΎϋ ϲϓ ϥϳΩέΎϧ ΕίΎΣ ΩϘϓ Ϫϧϭϋϭ ௌ ϝοϔΑϭ
internal system, and in 2004 the Underwriters Laboratories ΓΩΎϬη ϰϠϋ ΕίΎΣ ϡ 2004 ϡΎϋ ϲϓϭ ˬ(BS EN ISO 9001) ΔϳϣϟΎόϟ΍
(UL) safety mark. Thus assur-ing to our customers a reliable .(UL) ΔϳϛϳέϣϷ΍ Δϣϼγϟ΍ Δ΋ϳϫ Ε΍έΑΗΧϣ
and hassle-free service and product that e[tends to e[port
markets in other Gulf Countries and the Middle East region ˬΔϳΩϭόγϟ΍ ΔϳΑέόϟ΍ ΔϛϠϣϣϟ΍ ˯ΎΣϧ΃ ΔϓΎϛϟ ϥϳΩέΎϧ ΕΎΟΗϧϣ ΔϳρϐΗ ϥϋ ϼοϓϭ
as well. Our factory is equipped with modern machinery and ΔϳΑέόϟ΍ ϝϭΩϟ΍ ϡυόϣϟ ΔϓΎοϹΎΑ ϲΑέόϟ΍ ΞϳϠΧϟ΍ ϝϭΩ ϊϳϣΟϟ έΩλϧ ΎϧϧΈϓ
the most up-to-date production facilities, which create with
the backing of our quali¿ed electrical and mechanical engi- .ϯέΧϷ΍
neers a ¿ne line of high products presented in this edition, ΓέΎϧϹ΍ ϡϟΎϋ ϲϓ ϥϘΗϣϟ΍ ˯Ύρόϟ΍ ϥϣ Ωϳίϣϟ΍ ϰϟ· ϰόγϧ ௌ ϥϭόΑ Ύϧϟί ϻ Ύϣϛ
manufactured in accordance with international standards and
in full con-formity with Saudi Arabian Standard Organization ΙΩΣ΃ ϥϋ ϝλ΍ϭΗϣϟ΍ ΙΣΑϟ΍ϭ ϰϗέϷ΍ϭ ϰϣγϷ΍ ϭΣϧ ϝΛϣϷ΍ ϊϠρΗϟ΍ ϰϟ· ϭ
( SASO ). .ϝΎΟϣϟ΍ ΍Ϋϫ ϲϓ ΕΎϳϧϘΗϟ΍
Nardeen Luminaires are designed to be FINISH
architectural building elements, providing
To measure a long lasting protection of the
outstanding lighting performance with good visual
luminaires, utmost care is brought to the coating
comfort.
process, particularly treatments operations of
They are durable,easy to install and maintain.
the surface and powdering. This involves a
They can be used under demand environments.
multistage treatment of:
They incorporate only high grade, ef¿cacious
Degreasing and preparation of all surfaces.
materials and components.
Treatment with phosphates.
Nardeen indoor luminaires undergo tight quality
Electrostatically applied epo[y base polyester
controls and comply with e[isting international
powder ¿nishing.
standards.
Powder enamelling in stove ovens.

ELECTRICAL EQUIPMENT
The light ¿ttings are commonly supplied with
127/220V 60Hz, normal or rapid start, HPF
electrical circuits. LPF can be supplied on
request.
Other voltages 120/277V 60Hz rapid start,
220-240V 50Hz normal start, are available on
request.
Electronic, electronic dimmable ballast, RIS
capacitor and electronic starter also available on
request.
Special electrical wiring for countries with
particular standards are available on request.
PHOTOMETRIC LABORATORY AND
SOFTWARE
Luminaire optical design is supported by an
opto-mechanical software for pre-design and
testing in our laboratory to ensure its optical
data.
Polar, cone and cartesian intensity curves,
isolu[ curves, fast calculation table,
illuminance distribution, intensity table,
utilisation factors, luminance curves, light
output ratios, luminance classi¿cation.
The intensity data can be e[ported to any
lighting software design as «eulumdat» or
«ies» ¿les.

CUSTOMIZATION
To respond to most client demands, either in:
‡ Lighting results
‡ Aesthetic design
‡ Mechanical or dimensions adaptation
‡ New concept creation

We dispose of technical department «new


product» which design, develop, and
industrialize on demand of lighting solutions,
in relation with the clients.
Surface Mounted Luminaire
Rectangular Opal/Prismatic Rectangular Opal/Prismatic

SURFACE OPAL SURFACE PRISMATIC WHITE BASE OPAL WHITE BASE FLAT WHITE PLASTIC SILVER PLASTIC GOLDEN PLASTIC
PRISMATIC LOUVERS LOUVERS LOUVERS

SMO 18-19 SMP 20-21 WBO 22-23 WBP 24-25 RSL 64-65 RSLS 66-67 RSLG 68-69

RECTANGULAR FLAT RECTANGULAR FLAT RECTANGULAR WRAP- RECTANGULAR WRAP-


OPAL PRISMATIC AROUND OPAL AROUND PRISMATIC

RSO 26-27 RSP 28-29 RWO 30-31 RWP 32-33 Hygienic Luminaires
RECTANGULAR HEMI- HYGIENIC PLAIN
RECTANGULAR HEMI- ABOVE MIRROR ABOVE MIRROR HYGIENIC OPAL HYGIENIC PRISMATIC HYGIENIC ALUMINIUM
SPHERICAL DISHED ALUMINIUM PARABOLIC
SPHERICAL PRISMATIC LUMINAIRE OPAL LUMINAIRE PRISMATIC V-LOUVERS
LOUVERS LOUVERS

RHP 34-35 RHF 36-37 CWO 38-39 CWP 40-41 SFOH 70-71 SFPH 72-73 RSAH 74-75 RSSH 76-77

HYGIENIC WHITE
STEEL V-LOUVERS
Rectangular Louvers

RECTANGULAR ROUND CORNER RECTANGULAR PLAIN ROUND CORNER PLAIN


ALUMINIUM V-LOUVERS ALUMINIUM V-LOUVERS ALUMINIUM PARABOLIC ALUMINIUM PARABOLIC
V-LOUVERS LOUVERS
RSWH 78-79

RSA 42-43 RSAR 44-45 RSS 46-47 RSSR 48-49

RECTANGULAR WHITE ROUND CORNER WHITE RECTANGULAR ROUND DOUBLE PARABOLIC Circular Opal
STEEL V-LOUVERS STEEL V-LOUVERS ALUMINIUM V-LOUVERS MATT ALUMINIUM LOU-
VERS
CIRCULAR OPAL

RSW 50-51 RSWR 52-53 RRA 54-55 SDPM 56-57

SOC 80-81
DOUBLE PARABOLIC DEEP DOUBLE DEEP DOUBLE PARA-
SPECULAR ALUMINIUM PARABOLIC MATT ALU- BOLIC SEMI-SPECULAR
LOUVERS MINIUM LOUVERS ALUMINIUM LOUVERS

SDPS 58-59 SDDPM 60-61 SDDPS 62-63


Surface Opal
SERIES : SMO
IP53
Technical Data
To Order : follow the sequence mr - ln / ls - cgt - v/h - pf - acc - emu

Physical Characteristics

Frequency

Accessories
Voltage

Emergency
Reference

Lamp
Size

Optional
Number

Control

Power
Factor
Model

Lamp

/
Gear
Type

Unit
L W H

watt V / Hz mm mm mm

1 18 655 105 104


NS
Normal
1 36 Start 3/NM 1260 105 104
3 hours
FTB
DEOS Non-
Fused
1 58 Electronic Maintained 1560 105 104
Terminal
Starter
HPF Block
High
2 18 220 - 240V 665 190 84
Power TRW
SMP Factor Temperature
EB
50 / 60 Hz Resistant
2 36 Electronic 1260 190 84
Wire
High
Frequency
TW
Applications Suitable to be used in: of¿ces, clinics, education premises, circulation area general indoor application. 2 58 1560 190 84
HF Through
EBD 3/M
High Wire
Dimmable 3 hours
Made of press welded Cold Rolled Steel ³CRS´ sheet of tight construction to prevent light leakage, all metal 4 Frequency 665 665 87
18 Electronic Maintained
Housing parts pre-treated with a full degreasing and phosphate process, painted in stove enameled white baked epo[y High
polyester mi[-powder to ensure high reÀectance of painted surfaces. Other color ¿nishes upon request. Frequency
4 36 1260 430 87
Molded from one piece metacrylate opal sheet with sharply de¿ned rigid edges and corners. Diffuser is held to
Light Controller
the body by means of clamps.

Mounting Surface.

High Power Factor ³HPF´ ( • 90 ) Conventional Control Gear ³CCG´.


Control Gear High Frequency Electronic Control Gear ³ECG´. Photometrics & Dimensions
High Frequency Dimmable Electronic Control Gear ³ECG´.

220 - 240V , 50 / 60 Hz SMO 4/18w


Voltage / Frequency
³Other Voltages upon request´

1[22 mm ‘ hole on top.


Cable Entry
³E[tra knock-out holes upon request´

18, 36 58 watt T8/T26 Fluorescent for Normal Start ³NS´, Electronic Start ³DEOS´ or Electronic High
Frequency ³HF´ Ballast ³EB´.
17 32 watt T8 Fluorescent for Electronic High Frequency ³HF´ Ballast ³EB´.
14, 28 35 watt FH T5/T16 Fluorescent for Electronic High Frequency ³HF´ Ballast ³EB´.
Lamps
24, 49, 54 80 watt F4 T5/T16 Fluorescent for Electronic High Frequency ³HF´ Ballast ³EB´.

³Other lamps (T5/T16 ± T8/T26 ± TCL - TC-DE ± TC-TE) upon request ¿tting housing dimensions subMect to
changes accordingly´

3 Hours duration Emergency Unit ³EMU´ with battery pack Maintained ³/M´ or Non-Maintained ³/NM´ for one
Emergency Unit lamp, and for various lamp types and voltage networks combinations.
³Additional Emergency Units to operate more than one lamp on request´

18
Surface Prismatic
SERIES : SMP IP53
Technical Data
To Order : follow the sequence mr - ln / ls - cgt - v/h - pf - acc - emu

Physical Characteristics

Frequency

Accessories
Voltage

Emergency
Reference

Lamp
Size

Optional
Number

Control

Power
Factor
Model

Lamp

/
Gear
Type

Unit
L W H

watt V / Hz mm mm mm

1 18 655 105 104


NS
Normal
1 36 Start 3/NM 1260 105 104
3 hours
FTB
DEOS Non-
Fused
1 58 Electronic Maintained 1560 105 104
Terminal
Starter
HPF Block
High
2 18 220 - 240V 665 190 84
Power TRW
SMP Factor Temperature
EB
50 / 60 Hz Resistant
2 36 Electronic 1260 190 84
Wire
High
Frequency
TW
Applications Suitable to be used in: of¿ces, clinics, education premises, circulation area general indoor application. 2 58 1560 190 84
HF Through
EBD 3/M
High Wire
Dimmable 3 hours
Made of press welded Cold Rolled Steel “CRS” sheet of tight construction to prevent light leakage. All metal parts treated 4 Frequency 665 665 87
with full degreasing and phosphating process, painted in stove enameled white baked epo[y polyester mi[ powder to 18 Electronic Maintained
Housing High
ensure high reÀectance of painted surfaces.
Other color ¿nishes upon request. Frequency
4 36 1260 430 87
Molded from one piece metacrylate prismatic sheet with sharply de¿ned rigid edges and corners. Diffuser is held to the
Light Controller
body by means of clamps.

Mounting Surface.

Control Gear
High Power Factor “HPF” ( • 90 - 0.9 ) Conventional Control Gear “CCG”.
High Frequency Electronic Control Gear “ECG”. Photometrics & Dimensions
High Frequency Dimmable Electronic Control Gear “ECG”.

220 - 240V , 50 / 60 Hz SMP 4/18W


Voltage / Frequency
“Other Voltages upon request”

1[22 mm ‘ hole on top.


Cable Entry
E[tra knockout holes upon request.

18, 36 58 watt T8/T26 Fluorescent for Normal Start “NS”, Electronic Start “DEOS” or Electronic High Frequency “HF”
Ballast “EB”.
17,32 watt T8 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
Lamps 14,28 35 watt FH T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
24, 49, 54 80 watt F4 T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
Other lamps (T5/T16 – T8/T26 – TCL - TC-DE – TC-TE)
upon request ¿ttings housing dimensions subMect to changes accordingly.”.

3 hours duration Emergency Unit “EMU” with batteries pack Maintained “/M” or Non Maintained “/NM” for vari-
Emergency Unit ous lamp combinations and voltage networks. Additional Emergency additional Emergency.
Additional Emergency Units to operate more than one lamp on request.

20
White Base Opal
SERIES : WBO
IP53
Technical Data
To Order : follow the sequence mr - ln / ls - cgt - v/h - pf - acc - emu

Physical Characteristics

Frequency
Voltage

Accessories

Emergency
Lamp
Reference

Size

Optional
Number

Control

Power
Factor
Model

/
Lamp

Gear
Type

Unit
L W H - H1

watt V / Hz mm mm mm

1 623 175 35 - 110


14
NS
2 17 623 210 35 - 110
Normal
3/NM
3 18 Start 623 300 35 - 110
3 hours
24 FTB
Non-
4 DEOS Fused 623 623 35 - 110
Maintained
Electronic Terminal
1 Starter Block 623 175 35 - 110
28 HPF
2 220 - 240V High 1233 210 35 - 110
32 TRW
Power
WBO 36 EB Temperature
3 Factor 1233 300 35 - 110
Electronic 50 / 60 Hz Resistant
54 High Wire
4 1233 623 35 - 110
Frequency
Applications Suitable to be used in: of¿ces, clinics, education premises, circulation area general indoor application.
1 TW 1533 175 35 - 110
35 EBD Through
HF 3/M
Made of press welded Cold Rolled Steel “CRS” sheet of tight construction to prevent light leakage, all metal parts 2 Dimmable Wire 1533 210 35 - 110
49 High 3 hours
Housing pre-treated with a full degreasing and phosphate process, painted in stove enameled white baked epo[y polyester Electronic
3 58 Frequency Maintained 1533 300 35 - 110
mi[-powder to ensure high reÀectance of painted surfaces. “Other color ¿nishes upon request” High
80 Frequency
4 1533 623 35 - 110
Metacrylate opal sheet with strong e[truded opal pro¿le and sharply de¿ned rigid edges and corners. Diffuser is held to
Light Controller
the body by means of special springs allowing easy opening and diffuser suspension during maintenance.

Mounting Surface.

High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.


Control Gear High Frequency Electronic Control Gear “ECG”. Photometrics & Dimensions
High Frequency Dimmable Electronic Control Gear “ECG”.

220 - 240V , 50 / 60 Hz WBO 2/36W


Voltage / Frequency
“Other Voltages upon request”

1[22 mm ‘ hole on top.


Cable Entry
“E[tra knock-out holes upon request”
W
18, 36 58 watt T8/T26 Fluorescent for Normal Start “NS”, Electronic Start “DEOS” or Electronic High
Frequency “HF” Ballast “EB”.
17 32 watt T8 Fluorescent for Electronic High Frequency “HF” Ballast “EB”. H
Lamps 14, 28 35 watt FH T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
H1
24, 49, 54 80 watt F4 T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
“Other lamps (T5/T16 – T8/T26 – T12/T38 – TCL - TC-DE – TC-TE) upon request ¿tting housing dimensions
subMect to changes accordingly”
3 Hours duration Emergency Unit “EMU” with battery pack Maintained “/M” or Non-Maintained “/NM” for one
lamp, and for various lamp types and voltage networks combinations. L
Emergency Unit
“Additional Emergency Units to operate more than one lamp on request”

22
White Base Prismatic
SERIES : WBP
IP53
Technical Data
To Order : follow the sequence mr - ln / ls - cgt - v/h - pf - acc - emu

Physical Characteristics

Frequency

Accessories
Voltage
Lamp

Emergency
Reference

Size

Optional
Number

Control

Power
Factor
Model

Lamp

Gear
Type

Unit
L W H - H1

watt V / Hz mm mm mm

1 623 175 35 - 110


14
NS
2 17 Normal 623 210 35 - 110
3/NM
18 Start
3 3 hours 623 300 35 - 110
FTB
24 Non-
4 DEOS Fused 623 623 35 - 110
Maintained
Electronic Terminal
1 Starter Block 623 175 35 - 110
28 HPF
2 240V - 220 High 1233 210 35 - 110
32 TRW
Power
WBP 36 EB Temperature
3 Factor 1233 300 35 - 110
Electronic 50 / 60 Hz Resistant
54 High Wire
4 1233 623 35 - 110
Frequency
Applications Suitable to be used in: of¿ces, clinics, education premises, circulation area general indoor application. 1 TW 1533 175 35 - 110
35 EBD Through
HF 3/M
2 Dimmable Wire 1533 210 35 - 110
Made of press welded Cold Rolled Steel “CRS” sheet of tight construction to prevent light leakage, all metal parts 49 High 3 hours
Electronic
Housing pre-treated with a full degreasing and phosphate process, painted in stove enameled white baked epo[y polyester mi[- 3 58 Frequency Maintained 1533 300 35 - 110
High
powder to ensure high reÀectance of painted surfaces. “Other color ¿nishes upon request”
80 Frequency
4 1533 623 35 - 110
Metacrylate prismatic sheet with transparent e[truded pro¿le sharply de¿ned with rigid edges and corners. Diffus-
Light Controller
er is held to the body by means of special springs allowing easy opening and diffuser suspension during maintenance.

Mounting Surface.

Control Gear
High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.
High Frequency Electronic Control Gear “ECG”. Photometrics & Dimensions
High Frequency Dimmable Electronic Control Gear “ECG”.

220 - 240V , 50 / 60 Hz WBP 4/18W


Voltage / Frequency
“Other Voltages upon request”

1[22 mm ‘ hole on top.


Cable Entry
“E[tra knock-out holes upon request”
W
18, 36 58 watt T8/T26 Fluorescent for Normal Start “NS”, Electronic Start “DEOS” or Electronic High
Frequency “HF” Ballast “EB”.
17 32 watt T8 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
Lamps 14, 28 35 watt FH T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”. H
24, 49, 54 80 watt F4 T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”. H1
“Other lamps (T5/T16 – T8/T26 – T12/T38 – TCL - TC-DE – TC-TE) upon request ¿tting housing dimensions
subMect to changes accordingly”

3 Hours duration Emergency Unit “EMU” with battery pack Maintained “/M” or Non-Maintained “/NM” for one
Emergency Unit lamp, and for various lamp types and voltage networks combinations. L
“Additional Emergency Units to operate more than one lamp on request”

24
Rectangular Flat Opal
SERIES : RSO
IP23
Technical Data
To Order : follow the sequence mr - ln / ls - cgt - v/h - pf - acc - emu

Physical Characteristics

Frequency

Accessories
Voltage

Emergency
Lamp
Reference

Optional
Size
Number

Control

Power
Factor
Model

/
Lamp

Gear
Type

Unit
L W H

watt V / Hz mm mm mm

1 14 624 196 90
2 17 624 305 90
3 18 624 450 90
NS
4 24 Normal 624 624 90
3/NM
Start
1 FTB 3 hours 1226 196 90
28 Fused Non-
2 DEOS 1226 305 90
32 Terminal Maintained
RSO Electronic
36 Block
3 Starter 1226 450 90
HPF
4 54 High TRW 1226 624 90
220 - 240V
Power Temperature
1 EB 1526 196 90
35 Factor Resistant
Electronic
2 49
50 / 60 Hz Wire 1526 305 90
High
3 58 Frequency 1526 450 90
TW
Applications Suitable to be used in: of¿ces, clinics, education premises, circulation area general indoor application. 4 80 Through 1526 624 90
EBD
HF Wire 3/M
Dimmable
11L High 3 hours
Electronic
Made of press welded Cold Rolled Steel “CRS” sheet of tight construction to prevent light leakage, diffuser frame made of 13D/T Frequency Maintained
1 High 304 304 90
Plain Aluminum, All metal parts pre-treated with a full degreasing and phosphate process, painted in stove enameled 18D/T
Housing Frequency
white baked epo[y polyester mi[-powder to ensure high reÀectance of painted surfaces. RSOC 18L
“Other color ¿nishes upon request” 26D/T
2 32T 304 304 304
Standard opal Àat diffuser secured in an e[truded aluminum frame ¿nished in satin white. Frame is held to the body by 42T
Light Controller
means of special springs allowing easy opening and diffuser suspension during maintenance.

Mounting Surface.

Control Gear
High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.
High Frequency Electronic Control Gear “ECG”. Photometrics & Dimensions
High Frequency Dimmable Electronic Control Gear “ECG”.

220 - 240V , 50 / 60 Hz WBP 4/18W


Voltage / Frequency
“Other Voltages upon request”

1[22 mm ‘ hole on top.


Cable Entry
“E[tra knock-out holes upon request”
W
18, 36 58 watt T8/T26 Fluorescent for Normal Start “NS”, Electronic Start “DEOS” or Electronic High
Frequency “HF” Ballast “EB”.
17 32 watt T8 Fluorescent for Electronic High Frequency “HF” Ballast “EB”. H
Lamps 14, 28 35 watt FH T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
24, 49, 54 80 watt F4 T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
“Other lamps (T5/T16 – T8/T26 – T12/T38 – TCL - TC-DE – TC-TE) upon request ¿tting housing dimensions
subMect to changes accordingly”

3 Hours duration Emergency Unit “EMU” with battery pack Maintained “/M” or Non-Maintained “/NM” for one
Emergency Unit lamp, and for various lamp types and voltage networks combinations. L
“Additional Emergency Units to operate more than one lamp on request”

26
Rectangular Flat Prismatic
SERIES : RSP
IP23
Technical Data
To Order : follow the sequence mr - ln / ls - cgt - v/h - pf - acc - emu

Physical Characteristics

Frequency

Accessories
Voltage

Emergency
Lamp
Reference

Optional
Size
Number

Control

Power
Factor
Model

/
Lamp

Gear
Type

Unit
L W H

watt V / Hz mm mm mm

1 14 624 196 90
2 17 624 305 90
3 18 624 450 90
NS
4 24 Normal 624 624 90
3/NM
Start
1 FTB 3 hours 1226 196 90
28 Fused Non-
2 DEOS 1226 305 90
32 HPF Terminal Maintained
RSP Electronic
3 36 High Block 1226 450 90
Starter
Power
4 54 Factor TRW 1226 624 90
220 - 240V
Temperature
1 35 EB 1526 196 90
Resistant
Electronic
2 49 50 / 60 Hz Wire 1526 305 90
High
3 58 Frequency 1526 450 90
HF TW
4 80 High Through 1526 624 90
Applications Suitable to be used in: of¿ces, clinics, education premises, circulation area general indoor application. EBD
Frequency Wire 3/M
11L Dimmable
3 hours
Made of press welded Cold Rolled Steel “CRS” sheet of tight construction to prevent light leakage, diffuser frame made of 1 13D/T Electronic 304 304 90
Maintained
Plain Aluminum, All metal parts pre-treated with a full degreasing and phosphate process, painted in stove enameled 18D/T High
Housing Frequency
white baked epo[y polyester mi[-powder to ensure high reÀectance of painted surfaces. RSPC 18L
“Other color ¿nishes upon request” 26D/T
2 32T 304 304 90
Standard prismatic Àat diffuser secured in an e[truded aluminum frame ¿nished in satin white. Frame is held to the 42T
Light Controller
body by means of special springs allowing easy opening and diffuser suspension during maintenance.

Mounting Surface.

Control Gear
High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.
High Frequency Electronic Control Gear “ECG”. Photometrics & Dimensions
High Frequency Dimmable Electronic Control Gear “ECG”.

220 - 240V , 50 / 60 Hz RSP 4/18W


Voltage / Frequency
“Other Voltages upon request”

1[22 mm ‘ hole on top.


Cable Entry
“E[tra knock-out holes upon request”
W
18, 36 58 watt T8/T26 Fluorescent for Normal Start “NS”, Electronic Start “DEOS” or Electronic High
Frequency “HF” Ballast “EB”.
17 32 watt T8 Fluorescent for Electronic High Frequency “HF” Ballast “EB”. H
Lamps 14, 28 35 watt FH T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
24, 49, 54 80 watt F4 T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
“Other lamps (T5/T16 – T8/T26 – T12/T38 – TCL - TC-DE – TC-TE) upon request ¿tting housing dimensions
subMect to changes accordingly”

3 Hours duration Emergency Unit “EMU” with battery pack Maintained “/M” or Non-Maintained “/NM” for one
Emergency Unit lamp, and for various lamp types and voltage networks combinations. L
“Additional Emergency Units to operate more than one lamp on request”

28
Rectangular Wraparound Opal
SERIES : RWO
IP23
Technical Data
To Order : follow the sequence mr - ln / ls - cgt - v/h - pf - acc - emu

Physical Characteristics

Accessories

Emergency
Frequency
Reference

Optional
Number

Voltage
Control

Power
Factor
Model

Lamp

Lamp

Gear
Type
Size

Unit
/
L W H

watt V / Hz mm mm mm
1 18 620 225 64
1 36 1240 225 64
1 58 1540 225 64
2 18 620 225 64
2 36 1240 225 64
NS
2 58 Normal 1540 225 64
3/NM
3 18 Start 620 350 64
FTB 3 hours
3 36 Fused Non- 1240 350 64
DEOS
Terminal Maintained
3 58 Electronic 1540 350 64
Block
Starter
4 18 HPF 620 450 64
4 36 220 - 240V High TRW 1240 450 64
Power Temperature
RWO 1 14 EB 585 225 64
Factor Resistant
Electronic 50 / 60 Hz Wire
1 28 High 1190 225 64
Frequency
1 80 TW 1490 225 64
Through
Applications Suitable to be used in: of¿ces, clinics, education premises, circulation area general indoor application. 2 14 EBD 585 225 64
HF Wire 3/M
Dimmable
2 28 High 3 hours 1190 225 64
Electronic
Frequency Maintained
Made of press welded Cold Rolled Steel “CRS” sheet of tight construction to prevent light leakage. All metal parts 2 80 High 1490 225 64
Housing pre-treated with a full degreasing and phosphate process, painted in stove enameled white baked epo[y polyester 3 14 Frequency 585 350 64
mi[-powder to ensure high reÀectance of painted surfaces. “Other color ¿nishes upon request”
3 28 1190 350 64
3 80 1490 350 64
One piece acrylic opal sheet bent into a U form.
Light Controller 4 14 585 450 64
Diffuser is ¿[ed to the body by means of two steel sheet end-cap painted white.
4 28 1190 450 64

Mounting Surface.

Control Gear
High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.
High Frequency Electronic Control Gear “ECG”. Photometrics & Dimensions
High Frequency Dimmable Electronic Control Gear “ECG”.

220 - 240V , 50 / 60 Hz RWO 4/18W


Voltage / Frequency
“Other Voltages upon request”

1[22 mm ‘ hole on top.


Cable Entry
“E[tra knock-out holes upon request”

18, 36 58 watt T8/T26 Fluorescent for Normal Start “NS”, Electronic Start “DEOS” or Electronic High
Frequency “HF” Ballast “EB”.
17 32 watt T8 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
Lamps 14, 28 35 watt FH T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
24, 49, 54 80 watt F4 T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
“Other lamps (T5/T16 – T8/T26 – T12/T38 – TCL - TC-DE – TC-TE) upon request ¿tting housing dimensions
subMect to changes accordingly”

3 Hours duration Emergency Unit “EMU” with battery pack Maintained “/M” or Non-Maintained “/NM” for one
Emergency Unit lamp, and for various lamp types and voltage networks combinations.
“Additional Emergency Units to operate more than one lamp on request”

30
Rectangular Wraparound Prismatic
SERIES : RWP
IP23
Technical Data
To Order : follow the sequence mr - ln / ls - cgt - v/h - pf - acc - emu

Physical Characteristics

Accessories

Emergency
Frequency
Reference

Optional
Number

Voltage
Control

Power
Factor
Model

Lamp

Lamp

Gear
Type
Size

Unit
/
L W H

watt V / Hz mm mm mm
1 18 620 225 64
1 36 1240 225 64
1 58 1540 225 64
2 18 620 225 64
2 36 1240 225 64
NS
2 58 Normal 1540 225 64
3/NM
3 18 Start 620 350 64
FTB 3 hours
3 36 Fused Non- 1240 350 64
DEOS
Terminal Maintained
3 58 Electronic 1540 350 64
Block
Starter
4 18 HPF 620 450 64
4 36 220 - 240V High TRW 1240 450 64
Power Temperature
RWP 1 14 EB 585 225 64
Factor Resistant
Electronic 50 / 60 Hz Wire
1 28 High 1190 225 64
Frequency
1 80 TW 1490 225 64
Through
Applications Suitable to be used in: of¿ces, clinics, education premises, circulation area general indoor application. 2 14 EBD 585 225 64
HF Wire 3/M
Dimmable
2 28 High 3 hours 1190 225 64
Electronic
Frequency Maintained
Made of press welded Cold Rolled Steel “CRS” sheet of tight construction to prevent light leakage. All metal parts 2 80 High 1490 225 64
Housing pre-treated with a full degreasing and phosphate process, painted in stove enameled white baked epo[y polyester 3 14 Frequency 585 350 64
mi[-powder to ensure high reÀectance of painted surfaces. “Other color ¿nishes upon request”
3 28 1190 350 64
3 80 1490 350 64
One piece acrylic prismatic sheet bent into a U form.
Light Controller 4 14 585 450 64
Diffuser is ¿[ed to the body by means of two steel sheet end-cap painted white.
4 28 1190 450 64

Mounting Surface.

Control Gear
High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.
High Frequency Electronic Control Gear “ECG”. Photometrics & Dimensions
High Frequency Dimmable Electronic Control Gear “ECG”.

220 - 240V , 50 / 60 Hz RWP 2/36W


Voltage / Frequency
“Other Voltages upon request”

1[22 mm ‘ hole on top.


Cable Entry
“E[tra knock-out holes upon request”

18, 36 58 watt T8/T26 Fluorescent for Normal Start “NS”, Electronic Start “DEOS” or Electronic High
Frequency “HF” Ballast “EB”.
17 32 watt T8 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
Lamps 14, 28 35 watt FH T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
24, 49, 54 80 watt F4 T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
“Other lamps (T5/T16 – T8/T26 – T12/T38 – TCL - TC-DE – TC-TE) upon request ¿tting housing dimensions
subMect to changes accordingly”

3 Hours duration Emergency Unit “EMU” with battery pack Maintained “/M” or Non-Maintained “/NM” for one
Emergency Unit lamp, and for various lamp types and voltage networks combinations.
“Additional Emergency Units to operate more than one lamp on request”

32
Rectangular Hemispherical Prismatic
SERIES : RHP
IP23
Technical Data
To Order : follow the sequence mr - ln / ls - cgt - v/h - pf - acc - emu

Physical Characteristics

Frequency
Voltage
Lamp
Size

Accessories

Emergency
Reference

Optional
Number

Control

Power
Factor
Model

Lamp

Gear
Type

Unit
L W H

watt V / Hz mm mm mm

14 FTB
2 17 Fused
EB Terminal 3/NM 616 240 75
18 HPF
Electronic Block 3 hours
24 High
High Non-
Power
Frequency 220 - 240V TRW Maintained
Factor
Temperature
RHP
Applications Suitable to be used in: of¿ces, clinics, education premises, circulation area general indoor application. EBD Resistant
Dimmable 50 / 60 Hz Wire
28 Electronic 3/M
HF
Made of press welded Cold Rolled Steel “CRS” sheet of tight construction to prevent light leakage. All metal parts 2 32 High TW 3 hours
High 1226 240 75
Housing pre-treated with a full degreasing and phosphate process, painted in stove enameled white baked epo[y polyester Frequency Through Maintained
36 Frequency
mi[-powder to ensure high reÀectance of painted surfaces. “Other color ¿nishes upon request” Wire
54

One piece translucent acrylic molded in a hemispherical shape.


Light Controller
Diffuser is ¿[ed to the body by means of two clicking lateral grooves.

Mounting Surface.

Control Gear
High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.
High Frequency Electronic Control Gear “ECG”. Photometrics & Dimensions
High Frequency Dimmable Electronic Control Gear “ECG”.

220 - 240V , 50 / 60 Hz RHP 2/36W


Voltage / Frequency
“Other Voltages upon request”

1[22 mm ‘ hole on top.


Cable Entry
“E[tra knock-out holes upon request”

18, 36 58 watt T8/T26 Fluorescent for Normal Start “NS”, Electronic Start “DEOS” or Electronic High
Frequency “HF” Ballast “EB”.
17 32 watt T8 Fluorescent for Electronic High Frequency “HF” Ballast “EB”. W
Lamps 14, 28 35 watt FH T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
24, 49, 54 80 watt F4 T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
“Other lamps (T5/T16 – T8/T26 – T12/T38 – TCL - TC-DE – TC-TE) upon request ¿tting housing dimensions
subMect to changes accordingly” H

3 Hours duration Emergency Unit “EMU” with battery pack Maintained “/M” or Non-Maintained “/NM” for one
Emergency Unit lamp, and for various lamp types and voltage networks combinations.
“Additional Emergency Units to operate more than one lamp on request” L

34
Rectangular Hemispherical Dished
Louvers
SERIES : RHF
IP20
Technical Data
To Order : follow the sequence mr - ln / ls - cgt - v/h - pf - acc - emu

Physical Characteristics

Frequency
Voltage
Lamp

Accessories
Size

Emergency
Reference

Optional
/
Number

Control

Power
Factor
Model

Lamp

Gear
Type

Unit
L W H

watt V / Hz mm mm mm

14 FTB
Fused
17 EB Terminal 3/NM
2 616 240 75
18 Electronic HPF Block 3 hours
24 High High Non-
Frequency 220 - 240V Power TRW Maintained
Factor Temperature
RHF
EBD Resistant
Dimmable 50 / 60 Hz Wire
28 Electronic HF 3/M
32 High High TW 3 hours
Applications Suitable to be used in: of¿ces, clinics, education premises, circulation area general indoor application. 2 Frequency Frequency Through Maintained 1226 240 75
36
Wire
54
Made of press welded Cold Rolled Steel “CRS” sheet of tight construction
to prevent light leakage,. All metal parts pre-treated with a full degreasing and phosphating process, painted in stove
Housing
enameled white baked epo[y polyester mi[-powder to ensure high reÀectance of painted surfaces.
“Other color ¿nishes upon request”

Light Controller Dished plate white metallic concaved louvers. Diffuser is ¿[ed to the body by means of two clicking lateral grooves.

Mounting Surface.
Photometrics & Dimensions
High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.
Control Gear High Frequency Electronic Control Gear “ECG”.
High Frequency Dimmable Electronic Control Gear “ECG”.
RSF 2/18W
220 - 240V , 50 / 60 Hz
Voltage / Frequency
“Other Voltages upon request”

Cable Entry 1[22 mm ‘ hole on top. “E[tra knock-out holes upon request”
W
18, 36 58 watt T8/T26 Fluorescent for Normal Start “NS”, Electronic Start “DEOS” or Electronic High
Frequency “HF” Ballast “EB”.
17 32 watt T8 Fluorescent for Electronic High Frequency “HF” Ballast “EB”. H
Lamps 14, 28 35 watt FH T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
24, 49, 54 80 watt F4 T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
“Other lamps (T5/T16 – T8/T26 – T12/T38 – TCL - TC-DE – TC-TE) upon request ¿tting housing dimensions
subMect to changes accordingly”
L
3 Hours duration Emergency Unit “EMU” with battery pack Maintained “/M” or Non-Maintained “/NM” for one
Emergency Unit lamp, and for various lamp types and voltage networks combinations.
“Additional Emergency Units to operate more than one lamp on request”

36
Above Mirror Luminaire Opal
SERIES : CWO
IP23
Technical Data
To Order : follow the sequence mr - ln / ls - cgt - v/h - pf - acc - emu

Physical Characteristics

Frequency

Accessories
Voltage

Emergency
Reference

Lamp
Size

Optional
Number

Control

Power
Factor
Model

Lamp

/
Gear
Type

Unit
L (T8) L (T5) W H

watt V / Hz mm mm mm mm

633 595 77 127


1
14 633 595 77 177
18 NS
-- -- --
2 Normal Pull Switch 3/NM
Start 3 hours -- -- --
Non-
DEOS Maintained 1240 1195 77 127
1
28 Electronic 1240 1195 77 177
HPF
Starter Rocker
36 High -- -- --
220 - 240V Switch
2 Power
EB
CWO Factor -- -- --
Electronic
High 50 / 60 Hz 1540 1495 77 127
Frequency
1 Normal -- -- --
Applications Suitable to be used in: of¿ces, clinics, education premises, circulation area general indoor application. EBD Socket
HF -- -- --
58 Dimmable Outlet 3/M
High
Made of press welded Cold Rolled Steel “CRS” sheet of tight construction to prevent light leakage. All metal parts Electronic 3 hours
80 Frequency 1540 1495 77 177
pre-treated with a full degreasing and phosphate process, painted in stove enameled white baked epo[y polyester High Maintained
Housing
mi[-powder to ensure high reÀectance of painted surfaces. Frequency
“Other color ¿nishes upon request” 2
-- -- --
One piece acrylic opal sheet bent into an L form. Diffuser is ¿[ed to the body by means of two steel sheet end-cap
Light Controller
painted white.

Mounting Surface.

Control Gear
High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.
High Frequency Electronic Control Gear “ECG”. Photometrics & Dimensions
High Frequency Dimmable Electronic Control Gear “ECG”.

220 - 240V , 50 / 60 Hz
Voltage / Frequency
“Other Voltages upon request” CWO 2/36W
Cable Entry 1[22 mm ‘ hole on top.“E[tra knock-out holes upon request”

18, 36 58 watt T8/T26 Fluorescent for Normal Start “NS”, Electronic Start “DEOS” or Electronic High
Frequency “HF” Ballast “EB”.
17 32 watt T8 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
Lamps 14, 28 35 watt FH T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
24, 49, 54 80 watt F4 T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
“Other lamps (T5/T16 – T8/T26 – T12/T38 – TCL - TC-DE – TC-TE) upon request ¿tting housing dimensions
subMect to changes accordingly”

3 Hours duration Emergency Unit “EMU” with battery pack Maintained “/M” or Non-Maintained “/NM” for one
Emergency Unit lamp, and for various lamp types and voltage networks combinations.
“Additional Emergency Units to operate more than one lamp on request”

“Can be provide with pull-switch, rocker-switch, normal socket outlet and socket outlet with isolator transformer on
Optional Accessories request”

38
Above Mirror Luminaire Prismatic
SERIES : CWP
IP23
Technical Data
To Order : follow the sequence mr - ln / ls - cgt - v/h - pf - acc - emu

Physical Characteristics

Frequency

Accessories
Voltage

Emergency
Reference

Lamp
Size

Optional
Number

Control

Power
Factor
Model

Lamp

/
Gear
Type

Unit
L (T8) L (T5) W H

watt V / Hz mm mm mm mm

633 595 77 127


1
14 633 595 77 177
18 NS
-- -- --
2 Normal 3/NM
Start Pull Switch 3 hours -- -- --
Non-
DEOS Maintained 1240 1195 77 127
1
28 Electronic 1240 1195 77 177
HPF
Starter
36 High -- -- --
220 - 240V Rocker Switch
2 Power
EB
CWP Factor -- -- --
Electronic
High 50 / 60 Hz 1540 1495 77 127
Frequency
1 Normal -- -- --
Applications Suitable to be used in: of¿ces, clinics, education premises, circulation area general indoor application. EBD Socket Outlet
HF -- -- --
58 Dimmable 3/M
High
Made of press welded Cold Rolled Steel “CRS” sheet of tight construction to prevent light leakage. All metal parts Electronic 3 hours
80 Frequency 1540 1495 77 177
pre-treated with a full degreasing and phosphate process, painted in stove enameled white baked epo[y polyester High Maintained
Housing
mi[-powder to ensure high reÀectance of painted surfaces. Frequency
“Other color ¿nishes upon request” 2
-- -- --
One piece acrylic prismatic sheet bent into an L form.
Light Controller
Diffuser is ¿[ed to the body by means of two steel sheet end-cap painted white.

Mounting Surface.

Control Gear
High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.
High Frequency Electronic Control Gear “ECG”. Photometrics & Dimensions
High Frequency Dimmable Electronic Control Gear “ECG”.

220 - 240V , 50 / 60 Hz
Voltage / Frequency
“Other Voltages upon request” CWP 2/36W
Cable Entry 1[22 mm ‘ hole on top. “E[tra knock-out holes upon request”

18, 36 58 watt T8/T26 Fluorescent for Normal Start “NS”, Electronic Start “DEOS” or Electronic High
Frequency “HF” Ballast “EB”.
20 40 watt T12/T38 Fluorescent for Rapid Start “RS”.
17 32 watt T8 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
Lamps
14, 28 35 watt FH T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
24, 49, 54 80 watt F4 T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
“Other lamps (T5/T16 – T8/T26 – T12/T38 – TCL - TC-DE – TC-TE) upon request ¿tting housing dimensions
subMect to changes accordingly”

3 Hours duration Emergency Unit “EMU” with battery pack Maintained “/M” or Non-Maintained “/NM” for one
Emergency Unit lamp, and for various lamp types and voltage networks combinations. “Additional Emergency Units to operate
more than one lamp on request”

“Can be provided with pull-switch, rocker-switch, normal socket outlet and socket outlet with isolator transformer on
Optional Accessories request”

40
Rectangular Aluminium V-Louvers
SERIES : RSA
IP20
Technical Data
To Order : follow the sequence mr - ln / ls - cgt - v/h - pf - acc - emu

Physical Characteristics

Frequency

Accessories
Voltage

Emergency
Lamp
Reference

Optional
Size
Number

Control

Power
Factor
Model

/
Lamp

Gear
Type

Unit
L W H

watt V / Hz mm mm mm

1 14 624 196 90
2 17 624 305 90
3 18 624 450 90
24 NS
4 Normal 3/NM 624 624 90
1 Start FTB 3 hours 1226 196 90
28
Fused Non-
2 32 DEOS Terminal Maintained 1226 305 90
RSA
3 36 Electronic Block 1226 450 90
HPF
Starter
54 High
4 220 - 240V TRW 1226 624 90
Power
EB Temperature
1 35 Factor 1526 196 90
Electronic Resistant
2 49 High 50 / 60 Hz Wire 1526 305 90
Frequency
3 58 1526 450 90
TW
4 80 EBD Through 1526 624 90
HF
Dimmable Wire 3/M
High
11L Electronic 3 hours
Frequency
Applications Suitable to be used in: of¿ces, clinics, education premises, circulation area general indoor application. 1 13D/T High Maintained 304 304 90
18D/T Frequency
Made of press welded Cold Rolled Steel “CRS” sheet of tight construction RSAC 18L
to prevent light leakage,. All metal parts pre-treated with a full degreasing and phosphating process, painted in stove 26D/T
Housing enameled white baked epo[y polyester mi[-powder to ensure high reÀectance of painted surfaces. 2 32T 304 304 90
R- models characterized with chamfered edges and plastic corners. 42T
“Other color ¿nishes upon request”

V shaped specular anodized aluminum louvers, with stepped surface strip aluminum cross-bafÀe. Louvers are held to
Light Controller
the body by means of special steel springs allowing easy opening and diffuser suspension during maintenance.

Mounting Surface.
Photometrics & Dimensions
High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.
Control Gear High Frequency Electronic Control Gear “ECG”.
High Frequency Dimmable Electronic Control Gear “ECG”.
RSA 4/36W
220 - 240V , 50 / 60 Hz
Voltage / Frequency
“Other Voltages upon request”

1[22 mm ‘ hole on top.


Cable Entry
“E[tra knock-out holes upon request”
18, 36 58 watt T8/T26 Fluorescent for Normal Start “NS”, Electronic Start “DEOS” or Electronic High
Frequency “HF” Ballast “EB”.
17 32 watt T8 Fluorescent for Electronic High Frequency “HF” Ballast “EB”. W
Lamps 14, 28 35 watt FH T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
24, 49, 54 80 watt F4 T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
“Other lamps (T5/T16 – T8/T26 – T12/T38 – TCL - TC-DE – TC-TE) upon request ¿tting housing dimensions H
subMect to changes accordingly”

3 Hours duration Emergency Unit “EMU” with battery pack Maintained “/M” or Non-Maintained “/NM” for one
lamp, and for various lamp types and voltage networks combinations. L
Emergency Unit
“Additional Emergency Units to operate more than one lamp on request”

42
Round Corner Aluminium V-Louvers
SERIES : RSAR IP20
Technical Data
To Order : follow the sequence mr - ln / ls - cgt - v/h - pf - acc - emu

Physical Characteristics

Frequency

Accessories
Voltage

Emergency
Lamp
Reference

Optional
Size
Number

Control

Power
Factor
Model

/
Lamp

Gear
Type

Unit
L W H

watt V / Hz mm mm mm

1 -- -- --
14
2 17 624 310 75
3 18 -- -- --
24
4 NS 630 630 75
Normal 3/NM
1 Start FTB 3 hours -- -- --
28
Fused Non-
2 32 1242 310 75
RSAR DEOS Terminal Maintained
3 36 Electronic HPF Block -- -- --
Starter High
54 220 - 240V
4 Power TRW 1242 630 75
EB Factor Temperature
1 Electronic Resistant -- -- --
35 High 50 / 60 Hz Wire
2 49 Frequency 1526 305 75
58 TW
3 EBD HF Through -- -- --
80 Dimmable High Wire 3/M
4 -- -- --
Electronic Frequency 3 hours
High Maintained
11L
Applications Suitable to be used in: of¿ces, clinics, education premises, circulation area general indoor application. 13D/T
Frequency
1 304 304 90
18D/T
Made of press welded Cold Rolled Steel “CRS” sheet of tight construction RSARC 18L
to prevent light leakage,. All metal parts pre-treated with a full degreasing and phosphating process, painted in stove 26D/T
Housing enameled white baked epo[y polyester mi[-powder to ensure high reÀectance of painted surfaces. 2 32T 304 304 90
R- models characterized with chamfered edges and plastic corners. 42T
“Other color ¿nishes upon request”

V shaped specular anodized aluminum louvers, with stepped surface strip aluminum cross-bafÀe. Louvers are held to
Light Controller
the body by means of special steel springs allowing easy opening and diffuser suspension during maintenance.

Mounting Surface.
Photometrics & Dimensions
High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.
Control Gear High Frequency Electronic Control Gear “ECG”.
High Frequency Dimmable Electronic Control Gear “ECG”.
RSAR 4/18W
220 - 240V , 50 / 60 Hz
Voltage / Frequency
“Other Voltages upon request”

1[22 mm ‘ hole on top.


Cable Entry
“E[tra knock-out holes upon request”
18, 36 58 watt T8/T26 Fluorescent for Normal Start “NS”, Electronic Start “DEOS” or Electronic High
Frequency “HF” Ballast “EB”.
17 32 watt T8 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
Lamps 14, 28 35 watt FH T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
24, 49, 54 80 watt F4 T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”. W
“Other lamps (T5/T16 – T8/T26 – T12/T38 – TCL - TC-DE – TC-TE) upon request ¿tting housing dimensions
subMect to changes accordingly”
H
3 Hours duration Emergency Unit “EMU” with battery pack Maintained “/M” or Non-Maintained “/NM” for one
Emergency Unit lamp, and for various lamp types and voltage networks combinations.
“Additional Emergency Units to operate more than one lamp on request”
L

44
Rectangular Plain Aluminium Parabolic
V-Louvers
SERIES : RSS IP20
Technical Data
To Order : follow the sequence mr - ln / ls - cgt - v/h - pf - acc - emu

Physical Characteristics

Frequency

Accessories
Voltage

Emergency
Lamp
Reference

Optional
Size
Number

Control

Power
Factor
Model

/
Lamp

Gear
Type

Unit
L W H

watt V / Hz mm mm mm

1 14 624 196 90
2 17 624 305 90
3 18 624 450 90
24 NS
4 Normal 3/NM 624 624 90
1 Start FTB 3 hours 1226 196 90
28 Fused Non-
2 32 DEOS Terminal Maintained 1226 305 90
RSS HPF
36 Electronic Block
3 High 1226 450 90
Starter
54 Power
4 220 - 240V TRW 1226 624 90
Factor
EB Temperature
1 35 Electronic Resistant 1526 196 90
2 High 50 / 60 Hz Wire 1526 305 90
49
Frequency
3 58 TW 1526 450 90
HF
80 EBD Through
4 High 1526 624 90
Dimmable Wire 3/M
Frequency
11L Electronic 3 hours
Applications Suitable to be used in: of¿ces, clinics, education premises, circulation area general indoor application. 13D/T High Maintained
1 304 304 90
18D/T Frequency
Made of press welded Cold Rolled Steel “CRS” sheet of tight construction RSSC 18L
to prevent light leakage,. All metal parts pre-treated with a full degreasing and phosphating process, painted in stove 26D/T
Housing enameled white baked epo[y polyester mi[-powder to ensure high reÀectance of painted surfaces. 2 32T 304 304 90
R- models characterized with chamfered edges and plastic corners. 42T
“Other color ¿nishes upon request”

V shaped matt anodized aluminum louvers, with strip plain aluminum cross-bafÀe. Louvers are held to the body by
Light Controller
means of special steel springs allowing easy opening and diffuser suspension during maintenance.

Mounting Surface.
Photometrics & Dimensions
High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.
Control Gear High Frequency Electronic Control Gear “ECG”.
High Frequency Dimmable Electronic Control Gear “ECG”.
RSS 4/18w
220 - 240V , 50 / 60 Hz
Voltage / Frequency
“Other Voltages upon request”

1[22 mm ‘ hole on top.


Cable Entry
“E[tra knock-out holes upon request” W
18, 36 58 watt T8/T26 Fluorescent for Normal Start “NS”, Electronic Start “DEOS” or Electronic High
Frequency “HF” Ballast “EB”.
17 32 watt T8 Fluorescent for Electronic High Frequency “HF” Ballast “EB”. H
Lamps 14, 28 35 watt FH T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
24, 49, 54 80 watt F4 T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
“Other lamps (T5/T16 – T8/T26 – T12/T38 – TCL - TC-DE – TC-TE) upon request ¿tting housing dimensions
subMect to changes accordingly”
L
3 Hours duration Emergency Unit “EMU” with battery pack Maintained “/M” or Non-Maintained “/NM” for one
Emergency Unit lamp, and for various lamp types and voltage networks combinations.
“Additional Emergency Units to operate more than one lamp on request”

46
Round Corner Plain Aluminium Parabolic
V-Louvers
IP20
SERIES : RSSR
Technical Data
To Order : follow the sequence mr - ln / ls - cgt - v/h - pf - acc - emu
Physical Characteristics

Frequency

Accessories
Voltage

Emergency
Lamp
Reference

Optional
Size
Number

Control

Power
Factor
Model

/
Lamp

Gear
Type

Unit
L W H

watt V / Hz mm mm mm

1 -- -- --
14
2 17 624 310 75
3 18 -- -- --
24 NS
4 630 630 75
Normal
FTB 3/NM
1 Start -- -- --
28 Fused 3 hours
Terminal Non-
2 32 DEOS 1242 310 75
RSSR Maintained
Electronic Block
3 36 Starter -- -- --
HPF
54 220 - 240V TRW
4 High 1242 630 75
Power Temperature
EB
1 Factor Resistant -- -- --
35 Electronic
High 50 / 60 Hz Wire
2 49 1526 305 75
Frequency
3 58 TW -- -- --
80 EBD Through
HF 3/M
4 Dimmable Wire -- -- --
High 3 hours
Electronic
Frequency Maintained
11L High
Applications Suitable to be used in: of¿ces, clinics, education premises, circulation area general indoor application. 1 13D/T Frequency 304 304 75
18D/T
Made of press welded Cold Rolled Steel “CRS” sheet of tight construction RSSRC 18L
to prevent light leakage,. All metal parts pre-treated with a full degreasing and phosphating process, painted in stove 26D/T
2 32T 304 304 75
Housing enameled white baked epo[y polyester mi[-powder to ensure high reÀectance of painted surfaces. 42T
R- models characterized with chamfered edges and plastic corners.
“Other color ¿nishes upon request”

V shaped matt anodized aluminum louvers, with strip plain aluminum cross-bafÀe. Louvers are held to the body by
Light Controller
means of special steel springs allowing easy opening and diffuser suspension during maintenance.

Mounting Surface.
Photometrics & Dimensions
High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.
Control Gear High Frequency Electronic Control Gear “ECG”.
High Frequency Dimmable Electronic Control Gear “ECG”.
RSSR 2/36W
220 - 240V , 50 / 60 Hz
Voltage / Frequency
“Other Voltages upon request”

1[22 mm ‘ hole on top.


Cable Entry
“E[tra knock-out holes upon request”
18, 36 58 watt T8/T26 Fluorescent for Normal Start “NS”, Electronic Start “DEOS” or Electronic High
Frequency “HF” Ballast “EB”. W
17 32 watt T8 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
Lamps 14, 28 35 watt FH T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
H
24, 49, 54 80 watt F4 T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
“Other lamps (T5/T16 – T8/T26 – T12/T38 – TCL - TC-DE – TC-TE) upon request ¿tting housing dimensions
subMect to changes accordingly”

L
3 Hours duration Emergency Unit “EMU” with battery pack Maintained “/M” or Non-Maintained “/NM” for one
Emergency Unit lamp, and for various lamp types and voltage networks combinations.
“Additional Emergency Units to operate more than one lamp on request”

48
Rectangular White Steel V Louvers
IP20
SERIES : RSW
Technical Data
To Order : follow the sequence mr - ln / ls - cgt - v/h - pf - acc - emu

Physical Characteristics

Frequency

Accessories
Voltage

Emergency
Reference

Lamp
Size

Optional
Number

Control

Power
Factor
Model

Lamp

Gear
Type

Unit
L W H

watt V / Hz mm mm mm
1 14 624 196 90
2 17 624 305 90
3 18 NS 624 450 90
4 24 Normal 3/NM 624 624 90
Start FTB 3 hours
1 28 Fused Non- 1226 196 90
2 32 DEOS Terminal Maintained 1226 305 90
RSW Electronic Block
3 36 1226 450 90
Starter HPF
4 54 220 - 240V High TRW 1226 624 90
EB Power Temperature
1 35 Electronic Factor Resistant 1526 196 90
2 49 High 50 / 60 Hz Wire 1526 305 90
Frequency
3 58 1526 450 90
TW
4 80 EBD Through 1526 624 90
11L Dimmable HF Wire 3/M
13D/T Electronic High 3 hours
Applications Suitable to be used in: of¿ces, clinics, education premises, circulation area general indoor application. 1 304 304 90
18D/T High Frequency Maintained
SMWC 18L Frequency
Made of press welded Cold Rolled Steel “CRS” sheet of tight construction
to prevent light leakage,. All metal parts pre-treated with a full degreasing and phosphating process, painted in stove 26D/T
Housing enameled white baked epo[y polyester mi[-powder to ensure high reÀectance of painted surfaces. 2 32T 304 304 90
R- models characterized with chamfered edges and plastic corners. 42T
“Other color ¿nishes upon request”
V shaped steel sheets louvers, with strip cross-bafÀe all painted white.
Light Controller Louvers are held to the body by means of special steel springs allowing easy opening and diffuser suspension during
maintenance.

Mounting Surface.
Photometrics & Dimensions
High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.
Control Gear High Frequency Electronic Control Gear “ECG”.
High Frequency Dimmable Electronic Control Gear “ECG”.
RSW 4/18W
220 - 240V , 50 / 60 Hz
Voltage / Frequency
“Other Voltages upon request”

1[22 mm ‘ hole on top.


Cable Entry W
“E[tra knock-out holes upon request”
18, 36 58 watt T8/T26 Fluorescent for Normal Start “NS”, Electronic Start “DEOS” or Electronic High
Frequency “HF” Ballast “EB”. H
17 32 watt T8 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
Lamps 14, 28 35 watt FH T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
24, 49, 54 80 watt F4 T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
“Other lamps (T5/T16 – T8/T26 – T12/T38 – TCL - TC-DE – TC-TE) upon request ¿tting housing dimensions
subMect to changes accordingly” L

3 Hours duration Emergency Unit “EMU” with battery pack Maintained “/M” or Non-Maintained “/NM” for one
Emergency Unit lamp, and for various lamp types and voltage networks combinations.
“Additional Emergency Units to operate more than one lamp on request”

50
Round Corner White Steel V Louvers
SERIES : RSWR
IP20
Technical Data
To Order : follow the sequence mr - ln / ls - cgt - v/h - pf - acc - emu

Physical Characteristics

Frequency

Accessories
Voltage

Emergency
Lamp
Reference

Optional
Size
Number

Control

Power
Factor
Model

/
Lamp

Gear
Type

Unit
L W H

watt V / Hz mm mm mm

1 -- -- --
14
2 17 624 310 75
3 18 -- -- --
24
4 NS 630 630 75
Normal NM/3
1 Start FTB hours 3 -- -- --
28
Fused Non-
2 32 DEOS HPF Terminal Maintained 1242 310 75
RSWR Electronic High Block
3 36 -- -- --
Starter Power
54 220 - 240V Factor TRW
4 1242 630 75
EB Temperature
1 Electronic Resistant -- -- --
35 High Wire
50 / 60 Hz
2 49 Frequency 1526 305 75
58 HF TW
3 EBD High Through -- -- --
80 Dimmable Frequency Wire M/3
4 -- -- --
Electronic hours 3
11L High Maintained
Applications Suitable to be used in: of¿ces, clinics, education premises, circulation area general indoor application. 1 13D/T Frequency 304 304 75
18D/T
SMWRC 18L
Made of press welded Cold Rolled Steel “CRS” sheet of tight construction 26D/T
to prevent light leakage,. All metal parts pre-treated with a full degreasing and phosphating process, painted in stove 2 32T 304 304 75
Housing enameled white baked epo[y polyester mi[-powder to ensure high reÀectance of painted surfaces. 42T
R- models characterized with chamfered edges and plastic corners.
“Other color ¿nishes upon request”
V shaped steel sheets louvers, with strip cross-bafÀe all painted white.
Light Controller Louvers are held to the body by means of special steel springs allowing easy opening and diffuser suspension during
maintenance.

Mounting Surface.
Photometrics & Dimensions
High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.
Control Gear High Frequency Electronic Control Gear “ECG”.
High Frequency Dimmable Electronic Control Gear “ECG”.
RSWR 2/36W
220 - 240V , 50 / 60 Hz
Voltage / Frequency
“Other Voltages upon request”

1[22 mm ‘ hole on top.


Cable Entry
“E[tra knock-out holes upon request”
18, 36 58 watt T8/T26 Fluorescent for Normal Start “NS”, Electronic Start “DEOS” or Electronic High
Frequency “HF” Ballast “EB”.
17 32 watt T8 Fluorescent for Electronic High Frequency “HF” Ballast “EB”. W
Lamps 14, 28 35 watt FH T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
24, 49, 54 80 watt F4 T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
“Other lamps (T5/T16 – T8/T26 – T12/T38 – TCL - TC-DE – TC-TE) upon request ¿tting housing dimensions H
subMect to changes accordingly”

3 Hours duration Emergency Unit “EMU” with battery pack Maintained “/M” or Non-Maintained “/NM” for one
L
Emergency Unit lamp, and for various lamp types and voltage networks combinations.
“Additional Emergency Units to operate more than one lamp on request”

52
Rectangular Round Aluminium
V-Louvers IP20
SERIES : RRA Technical Data
To Order : follow the sequence mr - ln / ls - cgt - v/h - pf - acc - emu

Physical Characteristics

Frequency
Voltage

Accessories

Emergency
Lamp
Reference

Size

Optional
Number

Control

Power
Factor
Model

/
Lamp

Gear
Type

Unit
L W H

watt V / Hz mm mm mm

1 622 190 75
14
NS
2 17 622 290 75
Normal
3/NM
3 18 Start -- -- --
FTB 3 hours
24 Fused Non-
4 DEOS -- -- --
HPF Terminal Maintained
Electronic
1 High Block 1232 190 75
Starter
28 Power
2 32 220 - 240V Factor TRW 1232 290 75
Temperature
RRA 3 36 EB -- -- --
Resistant
54 Electronic 50 / 60 Hz Wire
4 High -- -- --
Frequency
1 HF TW 1532 190 75
High Through
35 EBD
2 Frequency Wire 3/M 1532 290 75
Applications Suitable to be used in: of¿ces, clinics, education premises, circulation area general indoor application. Dimmable
49 3 hours
Electronic
3 58 Maintained -- -- --
High
Made of press welded Cold Rolled Steel “CRS” sheet of tight construction 80 Frequency
to prevent light leakage,. All metal parts pre-treated with a full degreasing and phosphating process, painted in stove 4 -- -- --
Housing
enameled white baked epo[y polyester mi[-powder to ensure high reÀectance of painted surfaces.
“Other color ¿nishes upon request”

Made of high brightened anodized aluminum V louvers. Louvers are held to the body by means of special steel springs
Light Controller
allowing easy opening and diffuser suspension during maintenance.

Mounting Surface.
Photometrics & Dimensions
High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.
Control Gear High Frequency Electronic Control Gear “ECG”.
High Frequency Dimmable Electronic Control Gear “ECG”.
RRA 1/36W
220 - 240V , 50 / 60 Hz
Voltage / Frequency
“Other Voltages upon request”
W
Cable Entry 1[22 mm ‘ hole on top. “E[tra knock-out holes upon request”

18, 36 58 watt T8/T26 Fluorescent for Normal Start “NS”, Electronic Start “DEOS” or Electronic High
Frequency “HF” Ballast “EB”.
17 32 watt T8 Fluorescent for Electronic High Frequency “HF” Ballast “EB”. H
Lamps 14, 28 35 watt FH T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
24, 49, 54 80 watt F4 T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
“Other lamps (T5/T16 – T8/T26 – TCL - TC-DE – TC-TE) upon request ¿tting housing dimensions subMect to
changes accordingly”

3 Hours duration Emergency Unit “EMU” with battery pack Maintained “/M” or Non-Maintained “/NM” for one
Emergency Unit lamp, and for various lamp types and voltage networks combinations. L
“Additional Emergency Units to operate more than one lamp on request”

54
Double Parabola Matt Aluminium
Louvers
SERIES : SDPM
IP20
Technical Data
To Order : follow the sequence mr - ln / ls - cgt - v/h - pf - acc - emu

Physical Characteristics

Frequency

Accessories
Voltage

Emergency
Reference

Lamp
Size

Optional
Number

Control

Power
Factor
Model

Lamp

/
Gear
Type

Unit
L W H

watt V / Hz mm mm mm

1 18 NS 624 196 110


Normal
1 36 3/NM 1224 196 110
Start
FTB 3 hours
1 58 Fused Non- 1524 196 110
DEOS
HPF Terminal Maintained
2 18 Electronic 624 305 110
High Block
Starter
2 36 Power 1224 305 110
220 - 240V Factor TRW
2 58 Temperature 1524 305 110
SDPM EB
Resistant
3 18 Electronic 50 / 60 Hz 620 620 110
Wire
High
3 36 Frequency 1224 620 110
HF TW
3 58 High Through 1524 620 110
EBD
Frequency Wire 3/M
4 18 Dimmable 620 620 110
3 hours
Electronic
4 36 Maintained 1224 620 110
High
Applications Suitable to be used in: of¿ces, clinics, education premises, circulation area general indoor application. Frequency
4 58 1524 620 110

Made of press welded Cold Rolled Steel “CRS” sheet of tight construction
to prevent light leakage,. All metal parts pre-treated with a full degreasing and phosphating process, painted in stove
Housing
enameled white baked epo[y polyester mi[-powder to ensure high reÀectance of painted surfaces.
“Other color ¿nishes upon request”

Double parabolic matt anodized aluminum louvers, with cut-off angle less than 60o. Louvers are held to the body by
Light Controller
means of special steel springs allowing easy opening and diffuser suspension during maintenance.

Mounting Surface.
Photometrics & Dimensions
High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.
Control Gear High Frequency Electronic Control Gear “ECG”.
High Frequency Dimmable Electronic Control Gear “ECG”.
SDPM 4/18W
220 - 240V , 50 / 60 Hz
Voltage / Frequency
“Other Voltages upon request”

1[22 mm ‘ hole on top.


Cable Entry
“E[tra knock-out holes upon request”
18, 36 58 watt T8/T26 Fluorescent for Normal Start “NS”, Electronic Start “DEOS” or Electronic High
Frequency “HF” Ballast “EB”.
17 32 watt T8 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
Lamps 14, 28 35 watt FH T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
24, 49, 54 80 watt F4 T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
“Other lamps (T5/T16 – T8/T26 – T12/T38 – TCL - TC-DE – TC-TE) upon request ¿tting housing dimensions
subMect to changes accordingly”

3 Hours duration Emergency Unit “EMU” with battery pack Maintained “/M” or Non-Maintained “/NM” for one
Emergency Unit lamp, and for various lamp types and voltage networks combinations.
“Additional Emergency Units to operate more than one lamp on request”

56
Double Parabolic Specular Aluminium
Louvers
SERIES : SDPS IP20
Technical Data
To Order : follow the sequence mr - ln / ls - cgt - v/h - pf - acc - emu

Physical Characteristics

Frequency

Accessories
Voltage

Emergency
Reference

Lamp
Size

Optional
Number

Control

Power
Factor
Model

Lamp

/
Gear
Type

Unit
L W H

watt V / Hz mm mm mm

1 18 NS 624 196 110


Normal
1 36 3/NM 1224 196 110
Start
FTB 3 hours
1 58 Fused Non- 1524 196 110
DEOS
HPF Terminal Maintained
2 18 Electronic 624 305 110
High Block
Starter
2 36 Power 1224 305 110
220 - 240V Factor TRW
2 58 Temperature 1524 305 110
SDPS EB
Resistant
3 18 Electronic 50 / 60 Hz 620 620 110
Wire
High
3 36 Frequency 1224 620 110
HF TW
3 58 High Through 1524 620 110
EBD
Frequency Wire 3/M
4 18 Dimmable 620 620 110
3 hours
Electronic
4 36 Maintained 1224 620 110
High
Applications Suitable to be used in: of¿ces, clinics, education premises, circulation area general indoor application. Frequency
4 58 1524 620 110

Made of press welded Cold Rolled Steel “CRS” sheet of tight construction
to prevent light leakage,. All metal parts pre-treated with a full degreasing and phosphating process, painted in stove
Housing
enameled white baked epo[y polyester mi[-powder to ensure high reÀectance of painted surfaces.
“Other color ¿nishes upon request”

Double parabolic semi-specular anodized aluminum louvers, with cut-off angle less than 60o.Louvers are held to the
Light Controller
body by means of special steel springs allowing easy opening and diffuser suspension during maintenance.

Mounting Surface.
Photometrics & Dimensions
High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.
Control Gear High Frequency Electronic Control Gear “ECG”.
High Frequency Dimmable Electronic Control Gear “ECG”.
SDPS 4/36W
220 - 240V , 50 / 60 Hz
Voltage / Frequency
“Other Voltages upon request”

1[22 mm ‘ hole on top.


Cable Entry
“E[tra knock-out holes upon request”
18, 36 58 watt T8/T26 Fluorescent for Normal Start “NS”, Electronic Start “DEOS” or Electronic High
Frequency “HF” Ballast “EB”.
17 32 watt T8 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
Lamps 14, 28 35 watt FH T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
24, 49, 54 80 watt F4 T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
“Other lamps (T5/T16 – T8/T26 – T12/T38 – TCL - TC-DE – TC-TE) upon request ¿tting housing dimensions
subMect to changes accordingly”

3 Hours duration Emergency Unit “EMU” with battery pack Maintained “/M” or Non-Maintained “/NM” for one
Emergency Unit lamp, and for various lamp types and voltage networks combinations.
“Additional Emergency Units to operate more than one lamp on request”

58
Deep Double Parabolic Matt
Aluminium Louvers
IP20
SERIES : SDDPM
Technical Data
To Order : follow the sequence mr - ln / ls - cgt - v/h - pf - acc - emu

Physical Characteristics

Frequency
Voltage
Lamp
Size

Accessories

Emergency
Reference

Optional
Number

Control

Power
Factor
Model

Lamp

Gear
L W H

Type

Unit
watt V / Hz mm mm mm

2 18 NS 624 305 145


Normal 3/NM
Start FTB 3 hours
2 36 Fused Non- 1226 305 145
DEOS HPF Terminal Maintained
Electronic High Block
Starter Power
2 58 Factor TRW 1526 305 145
220 - 240V
EB Temperature
SDDPM
Electronic Resistant
High 50 / 60 Hz Wire
4 18 624 624 145
Frequency
HF TW
EBD High Through
4 36 Dimmable Frequency Wire 3/M 1226 624 145
Applications Suitable to be used in: of¿ces, clinics, education premises, circulation area general indoor application. Electronic 3 hours
High Maintained
Made of press welded Cold Rolled Steel “CRS” sheet of tight construction 4 58 Frequency 1526 624 145
to prevent light leakage,. All metal parts pre-treated with a full degreasing and phosphating process, painted in stove
Housing
enameled white baked epo[y polyester mi[-powder to ensure high reÀectance of painted surfaces.
“Other color ¿nishes upon request”

Deep double parabolic matt anodized aluminum louvers, with cut-off angle less than 55o. Louvers are held to the body
Light Controller
by means of special steel springs allowing easy opening and diffuser suspension during maintenance.

Mounting Surface.
Photometrics & Dimensions
High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.
Control Gear High Frequency Electronic Control Gear “ECG”.
High Frequency Dimmable Electronic Control Gear “ECG”.
SDDPM 4/36W
220 - 240V , 50 / 60 Hz
Voltage / Frequency
“Other Voltages upon request”

1[22 mm ‘ hole on top.


Cable Entry
“E[tra knock-out holes upon request”
18, 36 58 watt T8/T26 Fluorescent for Normal Start “NS”, Electronic Start “DEOS” or Electronic High
Frequency “HF” Ballast “EB”.
17 32 watt T8 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
Lamps 14, 28 35 watt FH T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
24, 49, 54 80 watt F4 T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
“Other lamps (T5/T16 – T8/T26 – T12/T38 – TCL - TC-DE – TC-TE) upon request ¿tting housing dimensions
subMect to changes accordingly”

3 Hours duration Emergency Unit “EMU” with battery pack Maintained “/M” or Non-Maintained “/NM” for one
Emergency Unit lamp, and for various lamp types and voltage networks combinations.
“Additional Emergency Units to operate more than one lamp on request”

60
Deep Double Parabolic Semi-Specular
Aluminium Louvers
SERIES : SDDPS IP20
Technical Data
To Order : follow the sequence mr - ln / ls - cgt - v/h - pf - acc - emu

Physical Characteristics

Frequency
Voltage
Lamp
Size

Accessories

Emergency
Reference

Optional
Number

Control

Power
Factor
Model

Lamp

Gear
L W H

Type

Unit
watt V / Hz mm mm mm

2 18 NS 624 305 145


Normal 3/NM
Start FTB 3 hours
2 36 Fused Non- 1226 305 145
DEOS HPF Terminal Maintained
Electronic High Block
Starter Power
2 58 Factor TRW 1526 305 145
220 - 240V
EB Temperature
SDDPS
Electronic Resistant
High 50 / 60 Hz Wire
4 18 624 624 145
Frequency
HF TW
EBD High Through
4 36 Dimmable Frequency Wire 3/M 1226 624 145
Applications Suitable to be used in: of¿ces, clinics, education premises, circulation area general indoor application. Electronic 3 hours
High Maintained
Made of press welded Cold Rolled Steel “CRS” sheet of tight construction 4 58 Frequency 1526 624 145
to prevent light leakage,. All metal parts pre-treated with a full degreasing and phosphating process, painted in stove
Housing
enameled white baked epo[y polyester mi[-powder to ensure high reÀectance of painted surfaces.
“Other color ¿nishes upon request”

Deep double parabolic semi-specular anodized aluminum louvers,


Light Controller with cut-off angle less than 55o.Louvers are held to the body by means of special steel springs allowing easy opening
and diffuser suspension during maintenance.

Mounting Surface.
Photometrics & Dimensions
High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.
Control Gear High Frequency Electronic Control Gear “ECG”.
High Frequency Dimmable Electronic Control Gear “ECG”.
SDDPS 4/18W
220 - 240V , 50 / 60 Hz
Voltage / Frequency
“Other Voltages upon request”

1[22 mm ‘ hole on top.


Cable Entry
“E[tra knock-out holes upon request”
18, 36 58 watt T8/T26 Fluorescent for Normal Start “NS”, Electronic Start “DEOS” or Electronic High
Frequency “HF” Ballast “EB”.
17 32 watt T8 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
Lamps 14, 28 35 watt FH T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
24, 49, 54 80 watt F4 T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
“Other lamps (T5/T16 – T8/T26 – T12/T38 – TCL - TC-DE – TC-TE) upon request ¿tting housing dimensions
subMect to changes accordingly”

3 Hours duration Emergency Unit “EMU” with battery pack Maintained “/M” or Non-Maintained “/NM” for one
Emergency Unit lamp, and for various lamp types and voltage networks combinations.
“Additional Emergency Units to operate more than one lamp on request”

62
Flat White Plastic Louvers
SERIES : RSL IP20
Technical Data
To Order : follow the sequence mr - ln / ls - cgt - v/h - pf - acc - emu

Physical Characteristics

Frequency

Accessories
Voltage

Emergency
Lamp
Reference

Optional
Size
Number

Control

Power
Factor
Model

/
Lamp

Gear
Type

Unit
L W H

watt V / Hz mm mm mm

1 624 196 90
14
2 17 624 305 90
3 18 624 450 90
24 NS
4 624 624 90
Normal
3/NM
1 Start 1226 196 90
28 FTB 3 hours
Fused Non-
2 32 DEOS 1226 305 90
RSL HPF Terminal Maintained
Electronic
3 36 High Block 1226 450 90
Starter
54 Power
4 220 - 240V Factor TRW 1226 624 90
Temperature
1 EB 1526 196 90
35 Resistant
Electronic
50 / 60 Hz Wire
2 49 High 1526 305 90
Frequency
3 58 HF TW 1526 450 90
High Through
80 EBD
4 Frequency Wire 3/M 1526 624 90
Dimmable
3 hours
Electronic
11L Maintained
Applications Suitable to be used in: of¿ces, clinics, education premises, circulation area general indoor application. High
1 13D/T Frequency 304 304 90
18D/T
Made of press welded Cold Rolled Steel “CRS” sheet of tight construction RSLC 18L
to prevent light leakage, diffuser frame made of Plain Aluminum, All metal parts pre-treated with a full degreasing and 26D/T
Housing phosphate process, painted in stove enameled white baked epo[y polyester mi[-powder to ensure high reÀectance of 2 32T 304 304 90
painted surfaces. 42T
“Other color ¿nishes upon request”

Flat half-inch styrene plastic silver louvers, secured in an e[truded aluminum frame painted white. Frame is held to the
Light Controller
body by means of special steel springs allowing easy opening and diffuser suspension during maintenance.

Mounting Surface.
Photometrics & Dimensions
High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.
Control Gear High Frequency Electronic Control Gear “ECG”.
High Frequency Dimmable Electronic Control Gear “ECG”.
RSL 4/18W
220 - 240V , 50 / 60 Hz
Voltage / Frequency
“Other Voltages upon request”

Cable Entry 1[22 mm ‘ hole on top. “E[tra knock-out holes upon request”

18, 36 58 watt T8/T26 Fluorescent for Normal Start “NS”, Electronic Start “DEOS” or Electronic High Frequency “HF”
Ballast “EB”.
14, 28 35 watt FH T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”. W
Lamps
24, 49, 54 80 watt F4 T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
“Other lamps (T5/T16 – T8/T26 - T12/T38 – TCL - TC-DE – TC-TE) upon request ¿tting housing dimensions
subMect to changes accordingly” H

3 Hours duration Emergency Unit “EMU” with battery pack Maintained “/M” or Non-Maintained “/NM” for one
Emergency Unit lamp, and for various lamp types and voltage networks combinations.
“Additional Emergency Units to operate more than one lamp on request
L

64
Silver Plastic Louvers
SERIES : RSLS IP20
Technical Data
To Order : follow the sequence mr - ln / ls - cgt - v/h - pf - acc - emu

Physical Characteristics

Frequency
Voltage

Accessories

Emergency
Lamp
Reference

Size

Optional
Number

Control

Power
Factor
Model

/
Lamp

Gear
Type

Unit
L W H

watt V / Hz mm mm mm

1 624 196 90
14
2 17 624 305 90
3 18 624 450 90
24 NS
4 Normal 624 624 90
3/NM
1 Start 1226 196 90
FTB 3 hours
28
Fused Non-
2 32 DEOS 1226 305 90
HPF Terminal Maintained
RSLS Electronic
3 36 High Block 1226 450 90
Starter
Power
54 220 - 240V Factor TRW
4 1226 624 90
Temperature
EB
1 Resistant 1526 196 90
35 Electronic
50 / 60 Hz Wire
2 High 1526 305 90
49
Frequency
58 HF TW
3 High Through 1526 450 90
80 EBD
4 Frequency Wire 3/M 1526 624 90
Dimmable
3 hours
Electronic
11L Maintained
Applications Suitable to be used in: of¿ces, clinics, education premises, circulation area general indoor application. High
1 13D/T Frequency 304 304 90
18D/T
Made of press welded Cold Rolled Steel “CRS” sheet of tight construction RSLSC 18L
to prevent light leakage, diffuser frame made of Plain Aluminum, All metal parts pre-treated with a full degreasing and 26D/T
Housing phosphate process, painted in stove enameled white baked epo[y polyester mi[-powder to ensure high reÀectance of 2 32T 304 304 90
painted surfaces. 42T
“Other color ¿nishes upon request”

Flat half-inch styrene plastic silver louvers, secured in an e[truded aluminum frame painted white. Frame is held to the
Light Controller
body by means of special steel springs allowing easy opening and diffuser suspension during maintenance.

Mounting Surface.
Photometrics & Dimensions
High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.
Control Gear High Frequency Electronic Control Gear “ECG”.
High Frequency Dimmable Electronic Control Gear “ECG”.
RSLS 4/18W
220 - 240V , 50 / 60 Hz
Voltage / Frequency
“Other Voltages upon request”

Cable Entry 1[22 mm ‘ hole on top. “E[tra knock-out holes upon request”

18, 36 58 watt T8/T26 Fluorescent for Normal Start “NS”, Electronic Start “DEOS” or Electronic High Frequency “HF” W
Ballast “EB”.
17 32 watt T8 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
Lamps 14, 28 35 watt FH T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”. H
24, 49, 54 80 watt F4 T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
“Other lamps (T5/T16 – T8/T26 - T12/T38 – TCL - TC-DE – TC-TE) upon request ¿tting housing dimensions
subMect to changes accordingly”

3 Hours duration Emergency Unit “EMU” with battery pack Maintained “/M” or Non-Maintained “/NM” for one L
Emergency Unit lamp, and for various lamp types and voltage networks combinations.
“Additional Emergency Units to operate more than one lamp on request”

66
Golden Plastic Louvers
SERIES : RSLG
IP20
Technical Data
To Order : follow the sequence mr - ln / ls - cgt - v/h - pf - acc - emu

Physical Characteristics

Frequency
Voltage

Accessories

Emergency
Lamp
Reference

Size

Optional
Number

Control

Power
Factor
Model

/
Lamp

Gear
Type

Unit
L W H

watt V / Hz mm mm mm

1 624 196 90
2 14 624 305 90
3 24 624 450 90
4 NS 624 624 90
Normal 3/NM
1 Start FTB 3 hours 1226 196 90
Fused Non-
2 28 1226 305 90
RSLG DEOS HPF Terminal Maintained
3 54 Electronic High Block 1226 450 90
Starter Power
4 220 - 240V Factor TRW 1226 624 90
EB Temperature
1 Electronic Resistant 1526 196 90
High 50 / 60 Hz Wire
2 35 Frequency 1526 305 90
3 80 HF TW 1526 450 90
EBD High Through
4 Dimmable Frequency Wire 3/M 1526 624 90
Electronic 3 hours
11L High Maintained
Applications Suitable to be used in: of¿ces, clinics, education premises, circulation area general indoor application. 13D/T Frequency
1 304 304 90
18D/T
Made of press welded Cold Rolled Steel “CRS” sheet of tight construction RSLGC 18L
to prevent light leakage, diffuser frame made of Plain Aluminum, All metal parts pre-treated with a full degreasing and 26D/T
Housing phosphate process, painted in stove enameled white baked epo[y polyester mi[-powder to ensure high reÀectance of 2 32T 304 304 90
painted surfaces. 42T
“Other color ¿nishes upon request”

Flat half-inch styrene plastic golden louvers, secured in an e[truded aluminum frame painted white. Frame is held to
Light Controller
the body by means of special steel springs allowing easy opening and diffuser suspension during maintenance.

Mounting Surface.
Photometrics & Dimensions
High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.
Control Gear High Frequency Electronic Control Gear “ECG”.
High Frequency Dimmable Electronic Control Gear “ECG”.
RSLG 2/36W
220 - 240V , 50 / 60 Hz
Voltage / Frequency
“Other Voltages upon request”

Cable Entry 1[22 mm ‘ hole on top. “E[tra knock-out holes upon request”

18, 36 58 watt T8/T26 Fluorescent for Normal Start “NS”, Electronic Start “DEOS” or Electronic High Frequency “HF” W
Ballast “EB”.
17 32 watt T8 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
Lamps 14, 28 35 watt FH T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”. H
24, 49, 54 80 watt F4 T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
“Other lamps (T5/T16 – T8/T26 - T12/T38 – TCL - TC-DE – TC-TE) upon request ¿tting housing dimensions
subMect to changes accordingly”

3 Hours duration Emergency Unit “EMU” with battery pack Maintained “/M” or Non-Maintained “/NM” for one L
Emergency Unit lamp, and for various lamp types and voltage networks combinations.
“Additional Emergency Units to operate more than one lamp on request”

68
IP65
Hygienic Opal
SERIES : SFOH

Technical Data
To Order : follow the sequence mr - ln / ls - cgt - v/h - pf - acc - emu

Physical Characteristics

Frequency
Voltage

Accessories

Emergency
Lamp
Reference

Size

Optional
Number

Control

Power
Factor
Model

/
Lamp

Gear
Type

Unit
L W H

watt V / Hz mm mm mm

1 635 196 90
14
2 17 635 250 90
3 18 635 450 90
24
4 NS 635 500 90
Normal 3/NM
1 Start FTB 3 hours 1240 196 90
28
Fused Non-
2 32 DEOS HPF Terminal Maintained 1240 250 90
SFOH
3 36 Electronic High Block 1240 450 90
Starter Power
54 220 - 240V Factor TRW
4 1240 500 90
EB Temperature
1 Electronic Resistant 1540 196 90
35 High 50 / 60 Hz Wire
2 49 Frequency 1540 250 90
58 HF TW
3 EBD High Through 1540 450 90
80 Dimmable Frequency Wire 3/M
4 1540 500 90
Electronic 3 hours
Suitable to be used in: Hygienic areas with low dust particles and germ counts, e.g. hospital, operating theaters, pharmacies, 11L High Maintained
Applications
laboratories, pharmaceutical, food processing, patients rooms, etc. 1 13D/T Frequency 250 250 107
18D/T
Made of press welded Cold Rolled Steel “CRS” sheet of tight construction SOHC 18L
to prevent light leakage, diffuser frame made of Plain Aluminum, All metal parts pre-treated with a full degreasing and phos- 26D/T
Housing 2 32T 250 250 107
phate process, painted in stove enameled white baked epo[y polyester mi[-powder to ensure high reÀectance of painted
surfaces. “Other color ¿nishes upon request” 42T

Standard opal Àat diffuser secured in an e[truded aluminum frame ¿nished in satin white. Louvers ¿[ed on white aluminum
frame incorporates tempered glass or polycarbonate hygienic layer, special UV resistant gasket seal ensures tight ¿t between
body and diffuser, suspension kit supplied for easy maintenance, also for easy installation, a suspension system consisting of a
Light Controller
special kit adMustable from inside the luminaire can be supplied on request. Hygienic layer features UV resistant, High resistant
for mechanical impact and high resistant for most of the disinfectant chemicals used in operation theatre rooms, delivery
rooms, etc… Photometrics & Dimensions
Mounting Surface.

High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”. SFOH 2/36W
Control Gear High Frequency Electronic Control Gear “ECG”.
High Frequency Dimmable Electronic Control Gear “ECG”.

220 - 240V , 50 / 60 Hz
Voltage / Frequency
“Other Voltages upon request”

Cable Entry 1[22 mm ‘ hole on top. “E[tra knock-out holes upon request”
W
18, 36 58 watt T8/T26 Fluorescent for Normal Start “NS”, Electronic Start “DEOS” or Electronic High Frequency “HF” Ballast
“EB”. H
17 32 watt T8 Fluorescent for Electronic High Frequency “HF” Ballast “EB”
Lamps
14, 28 35 watt FH T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”. 24, 49, 54 80 watt F4 T5/T16
Fluorescent for Electronic High Frequency “HF” Ballast “EB”. “Other lamps (T5/T16 – T8/T26 – T12/T38 – TCL - TC-DE – TC-
TE) upon request ¿tting housing dimensions subMect to changes accordingly”

L
3 Hours duration Emergency Unit “EMU” with battery pack Maintained “/M” or Non-Maintained “/NM” for one lamp,
Emergency Unit and for various lamp types and voltage networks combinations. “Additional Emergency Units to operate more than one
lamp on request”

70
IP65
Hygienic Prismatic
SERIES : SFPH

Technical Data
To Order : follow the sequence mr - ln / ls - cgt - v/h - pf - acc - emu

Physical Characteristics

Frequency
Voltage

Accessories

Emergency
Lamp
Reference

Size

Optional
Number

Control

Power
Factor
Model

/
Lamp

Gear
Type

Unit
L W H

watt V / Hz mm mm mm

1 635 196 90
14
2 17 635 250 90
3 18 635 450 90
24
4 NS 635 500 90
Normal 3/NM
1 Start FTB 3 hours 1240 196 90
28
Fused Non-
2 32 DEOS HPF Terminal Maintained 1240 250 90
SFPH
3 36 Electronic High Block 1240 450 90
Starter Power
54 220 - 240V Factor TRW
4 1240 500 90
EB Temperature
1 Electronic Resistant 1540 196 90
35 High 50 / 60 Hz Wire
2 49 Frequency 1540 250 90
58 HF TW
3 EBD High Through 1540 450 90
80 Dimmable Frequency Wire 3/M
4 1540 500 90
Electronic 3 hours
Suitable to be used in: Hygienic areas with low dust particles and germ counts, e.g. hospital, operating theaters, pharmacies, 11L High Maintained
Applications Frequency
laboratories, pharmaceutical, food processing, patients rooms, etc. 1 13D/T 250 250 107
18D/T
SPHC 18L
Made of press welded Cold Rolled Steel “CRS” sheet of tight construction
to prevent light leakage, diffuser frame made of Plain Aluminum, All metal parts pre-treated with a full degreasing and phos- 26D/T
Housing 2 32T 250 250 107
phate process, painted in stove enameled white baked epo[y polyester mi[-powder to ensure high reÀectance of painted
surfaces. “Other color ¿nishes upon request” 42T

Standard prismatic Àat diffuser secured in an e[truded aluminum frame ¿nished in satin white.Louvers ¿[ed on white aluminum
frame incorporates tempered glass or polycarbonate hygienic layer, special UV resistant gasket seal ensures tight ¿t between
body and diffuser, suspension kit supplied for easy maintenance,also for easy installation, a suspension system consisting of a
Light Controller
special kit adMustable from inside the luminaire can be supplied on request. Hygienic layer features UV resistant, High resistant
for mechanical impact and high resistant for most of the disinfectant chemicals used in operation theatre rooms, delivery
rooms, etc. Photometrics & Dimensions
Mounting Surface.

High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”. SFPH 4/18W
Control Gear High Frequency Electronic Control Gear “ECG”.
High Frequency Dimmable Electronic Control Gear “ECG”.

220 - 240V , 50 / 60 Hz
Voltage / Frequency
“Other Voltages upon request”

Cable Entry 1[22 mm ‘ hole on top. “E[tra knock-out holes upon request” W

18, 36 58 watt T8/T26 Fluorescent for Normal Start “NS”, Electronic Start “DEOS” or Electronic High Frequency “HF” Ballast H
“EB”.
17 32 watt T8 Fluorescent for Electronic High Frequency “HF” Ballast “EB”
Lamps
14, 28 35 watt FH T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”. 24, 49, 54 80 watt F4 T5/T16
Fluorescent for Electronic High Frequency “HF” Ballast “EB”. “Other lamps (T5/T16 – T8/T26 – T12/T38 – TCL - TC-DE – TC-
TE) upon request ¿tting housing dimensions subMect to changes accordingly”

L
3 Hours duration Emergency Unit “EMU” with battery pack Maintained “/M” or Non-Maintained “/NM” for one lamp,
Emergency Unit and for various lamp types and voltage networks combinations. “Additional Emergency Units to operate more than one
lamp on request”

72
IP65
Hygienic Aluminium V-Louvers
SERIES : RSAH

Technical Data
To Order : follow the sequence mr - ln / ls - cgt - v/h - pf - acc - emu

Physical Characteristics

Frequency
Voltage

Accessories

Emergency
Lamp
Reference

Size
Number

Control

Power
Factor
Model

/
Lamp

Gear
Type

Unit
L W H

watt V / Hz mm mm mm

1 14 630 196 90
2 17 630 250 90
18
3 630 450 90
20
NS
4 24 Normal 630 500 90
3/NM
Start
1 FTB 3 hours 1226 196 90
28
Fused Non-
32 DEOS HPF
2 Terminal Maintained 1226 250 90
RSAH Electronic High
36 Block
3 Starter Power 1226 450 90
40 Factor
220 - 240V TRW
4 54 Temperature 1226 500 90
EB
Resistant
Electronic
1 50 / 60 Hz Wire 1526 196 90
35 High
2 Frequency HF 1526 250 90
49 TW
High
3 58 Through 1526 450 90
EBD Frequency
Wire 3/M
Suitable to be used in: Hygienic areas with low dust particles and germ counts, e.g. hospital, operating theaters, pharmacies, 80 Dimmable
Applications 4 3 hours 1526 500 90
laboratories, pharmaceutical, food processing, patients rooms, etc. Electronic
Maintained
11L High
Made of press welded Cold Rolled Steel “CRS” sheet of tight construction 13D/T Frequency
1 250 250 107
to prevent light leakage, diffuser frame made of Plain Aluminum. All metal parts pre-treated with a full degreasing and phos- 18D/T
Housing SAHC 18L
phating process, painted in stove enameled white baked epo[y polyester mi[-powder to ensure high reÀectance of painted
surfaces. R- models characterized with chamfered edges and plastic corners. “Other color ¿nishes upon request” 26D/T
2 32T 250 250 107
V shaped specular anodized aluminum mirror louvers, with stepped surface strip aluminum cross-blades. Louvers ¿[ed on 42T
white aluminum frame incorporates tempered glass or polycarbonate hygienic layer, special UV resistant gasket seal en-
sures tight ¿t between body and diffuser, suspension kit supplied for easy maintenance, also for easy installation, a suspen-
Light Controller
sion system consisting of a special kit adMustable from inside the luminaire can be supplied on request. Hygienic layer features
UV resistant, High resistant for mechanical impact and high resistant for most of the disinfectant chemicals used in operation
theatre rooms, delivery rooms, etc. Photometrics & Dimensions
Mounting Surface.

High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”. RSAH 4/18W
Control Gear High Frequency Electronic Control Gear “ECG”.
High Frequency Dimmable Electronic Control Gear “ECG”.

220 - 240V , 50 / 60 Hz
Voltage / Frequency
“Other Voltages upon request”

Cable Entry 1[22 mm ‘ hole on top. “E[tra knock-out holes upon request”

18, 36 58 watt T8/T26 Fluorescent for Normal Start “NS”, Electronic Start “DEOS” or Electronic High Frequency “HF” Ballast
“EB”. W
17 32 watt T8 Fluorescent for Electronic High Frequency HF Ballast EB
Lamps
14, 28 35 watt FH T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”. 24, 49, 54 80 watt F4 T5/T16
Fluorescent for Electronic High Frequency “HF” Ballast “EB”. “Other lamps (T5/T16 – T8/T26 – T12/T38 – TCL - TC-DE – TC- H
TE) upon request ¿tting housing dimensions subMect to changes accordingly”

3 Hours duration Emergency Unit “EMU” with battery pack Maintained “/M” or Non-Maintained “/NM” for one lamp,
Emargency Unit and for various lamp types and voltage networks combinations. “Additional Emergency Units to operate more than one
lamp on request” L

74
IP65
Hygienic Plain Aluminium V-Louvers
SERIES : RSSH

Technical Data
To Order : follow the sequence mr - ln / ls - cgt - v/h - pf - acc - emu

Physical Characteristics

Frequency
Voltage

Accessories

Emergency
Lamp
Reference

Size

Optional
Number

Control

Power
Factor
Model

/
Lamp

Gear
Type

Unit
L W H

watt V / Hz mm mm mm

1 630 196 90
14
2 17 630 250 90
3 18 630 450 90
NS
24 Normal
4 3/NM 630 500 90
Start
1 FTB 3 hours 1226 196 90
28 Fused Non-
DEOS HPF
2 32 Terminal Maintained 1226 250 90
RSSH Electronic High
Block
3 36 Starter Power 1226 450 90
Factor
54 220 - 240V TRW
4 1226 500 90
Temperature
EB
1 35 Resistant 1526 196 90
Electronic
50 / 60 Hz Wire
2 49 High 1526 250 90
Frequency HF
3 58 TW 1526 450 90
High
80 Through
4 EBD Frequency 1526 500 90
Wire 3/M
Dimmable
11L 3 hours
Electronic
Suitable to be used in: Hygienic areas with low dust particles and germ counts, e.g. hospital, operating theaters, pharmacies, 13D/T Maintained
Applications 1 High 250 250 107
laboratories, pharmaceutical, food processing, patients rooms, etc. 18D/T Frequency
SSHC 18L
Made of press welded Cold Rolled Steel “CRS” sheet of tight construction 26D/T
to prevent light leakage, diffuser frame made of Plain Aluminum, all metal parts pre-treated with a full degreasing and phos- 2 32T 250 250 107
Housing
phating process, painted in stove enameled white baked epo[y polyester mi[-powder to ensure high reÀectance of painted 42T
surfaces. “Other color ¿nishes upon request”

V shaped matt anodized aluminum louvers, with strip plain aluminum cross-bafÀe. Louvers ¿[ed on white aluminum frame incor-
porates tempered glass or polycarbonate hygienic layer, special UV resistant gasket seal ensures tight ¿t between body and
diffuser, suspension kit supplied for easy maintenance, also for easy installation, a suspension system consisting of a special
Light Controller kit adMustable from inside the luminaire can be supplied on request.
Hygienic layer features UV resistant, High resistant for mechanical impact
and high resistant for most of the disinfectant chemicals used in operation
theatre rooms, delivery rooms, etc…
Photometrics & Dimensions
Mounting Surface.

RSSH 4/18W
High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.
Control Gear High Frequency Electronic Control Gear “ECG”.
High Frequency Dimmable Electronic Control Gear “ECG”.

220 - 240V , 50 / 60 Hz
Voltage / Frequency
“Other Voltages upon request”

Cable Entry 1[22 mm ‘ hole on top. “E[tra knock-out holes upon request”
W
18, 36 58 watt T8/T26 Fluorescent for Normal Start “NS”, Electronic Start “DEOS” or Electronic High Frequency “HF” Ballast
“EB”.
17 32 watt T8 Fluorescent for Electronic High Frequency “HF” Ballast “EB” H
Lamps
14, 28 35 watt FH T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”. 24, 49, 54 80 watt F4 T5/T16
Fluorescent for Electronic High Frequency “HF” Ballast “EB”. “Other lamps (T5/T16 – T8/T26 – T12/T38 – TCL - TC-DE – TC-
TE) upon request ¿tting housing dimensions subMect to changes accordingly”

3 Hours duration Emergency Unit “EMU” with battery pack Maintained “/M” or Non-Maintained “/NM” for one lamp, L
Emergency Unit and for various lamp types and voltage networks combinations. “Additional Emergency Units to operate more than one
lamp on request”

76
IP65
Hygienic White Steel V-Louvers
SERIES : RSWH

Technical Data
To Order : follow the sequence mr - ln / ls - cgt - v/h - pf - acc - emu

Physical Characteristics

Frequency
Voltage

Accessories

Emergency
Lamp
Reference

Size

Optional
Number

Control

Power
Factor
Model

/
Lamp

Gear
Type

Unit
L W H

watt V / Hz mm mm mm

1 630 196 90
14
2 17 630 250 90
3 18 630 450 90
24 NS
4 Normal 630 500 90
3/NM
Start
1 FTB 3 hours 1226 196 90
28
Fused Non-
2 32 DEOS 1226 250 90
RSWH LFB Terminal Maintained
Electronic
3 36 LOW Block 1226 450 90
Starter
Power
54
4 220 - 240V Factor TRW 1226 500 90
Temperature
1 35 EB 1526 196 90
Resistant
Electronic
2 49 50 / 60 Hz Wire 1526 250 90
High
58 Frequency
3 HF TW 1526 450 90
80 High Through
4 EBD 1526 500 90
Frequency Wire 3/M
Dimmable
Suitable to be used in: Hygienic areas with low dust particles and germ counts, e.g. hospital, operating theaters, pharmacies, 11L 3 hours
Applications Electronic
laboratories, pharmaceutical, food processing, patients rooms, etc. 1 13D/T Maintained 250 250 107
High
18D/T Frequency
Made of press welded Cold Rolled Steel “CRS” sheet of tight construction SWHC 18L
to prevent light leakage, diffuser frame made of Plain Aluminum, all metal parts pre-treated with a full degreasing and phos- 26D/T
Housing 2 32T 250 250 107
phating process, painted in stove enameled white baked epo[y polyester mi[-powder to ensure high reÀectance of painted
surfaces. R- models characterized with chamfered edges and plastic corners.. “Other color ¿nishes upon request” 42T

V shaped steel sheets louvers, with strip cross-bafÀe all painted white. Louvers ¿[ed on white aluminum frame incorporates
tempered glass or
polycarbonate hygienic layer, special UV resistant gasket seal ensures tight ¿t between body and diffuser, suspension kit
Light Controller
supplied for easy maintenance, also for easy installation, a suspension system consisting of a special kit adMustable from inside
the luminaire can be supplied on request. Hygienic layer features UV resistant, High resistant for mechanical impact and high
resistant for most of the disinfectant chemicals used in operation theatre rooms, delivery rooms, etc. Photometrics & Dimensions
Mounting Surface.

High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”. RSWH 2/36W
Control Gear High Frequency Electronic Control Gear “ECG”.
High Frequency Dimmable Electronic Control Gear “ECG”.

220 - 240V , 50 / 60 Hz
Voltage / Frequency
“Other Voltages upon request”

Cable Entry 1[22 mm ‘ hole on top. “E[tra knock-out holes upon request”

18, 36 58 watt T8/T26 Fluorescent for Normal Start “NS”, Electronic Start “DEOS” or Electronic High Frequency “HF” Ballast
“EB”. W
17 32 watt T8 Fluorescent for Electronic High Frequency “HF” Ballast “EB”
Lamps
14, 28 35 watt FH T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”. 24, 49, 54 80 watt F4 T5/T16
Fluorescent for Electronic High Frequency “HF” Ballast “EB”. “Other lamps (T5/T16 – T8/T26 – T12/T38 – TCL - TC-DE – TC- H
TE) upon request ¿tting housing dimensions subMect to changes accordingly”

3 Hours duration Emergency Unit “EMU” with battery pack Maintained “/M” or Non-Maintained “/NM” for one lamp,
Emergency Unit and for various lamp types and voltage networks combinations. “Additional Emergency Units to operate more than one
lamp on request” L

78
Circular Opal
SERIES : SOC IP53
Technical Data
To Order : follow the sequence mr - ln / ls - cgt - v/h - pf - acc - emu

Physical Characteristics

Frequency
Voltage

Emergency
Lamp
Reference

Accessories
Size
Number

Control

Optional
Power
Factor
Model

/
Lamp

Gear
Type

Unit
L W H

watt V / Hz mm mm mm

1 337 -- 90
NS -- -- --
FTB
32 Normal
Fused 3/NM
Start -- -- --
Terminal 3 hours
Block Non-
DEOS -- -- --
HPF Maintained
Electronic
1 High 452 -- 90
Starter
40 Power TRW
220 - 240V Factor Temperature -- -- --
55 Resistant
SOC EB
Wire -- -- --
Electronic 50 / 60 Hz
60 High
-- -- --
Frequency
HF TW
1 High Through -- -- --
Applications Suitable to be used in: circulation area, stairs, general indoor applications. EBD
Frequency Wire 3/M
40 + 32 Dimmable 452 -- 90
3 hours
Made of press welded Cold Rolled Steel “CRS” sheet of tight construction Electronic
Maintained
to prevent light leakage, diffuser frame made of Plain Aluminum, all metal parts pre-treated with a full degreasing and phos- High -- -- --
Housing phate process, painted in stove enameled white baked epo[y polyester mi[-powder to ensure high reÀectance of painted 60 + 32 Frequency
surfaces. -- -- --
“Other color ¿nishes upon request”

One piece, non glued, molded metacrylate opal, UV resistant. Diffuser is held to the body by means of special springs allowing
Light Controller
easy opening and suspension during maintenance.

Mounting Surface.
Photometrics & Dimensions
High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.
Control Gear High Frequency Electronic Control Gear “ECG”.
High Frequency Dimmable Electronic Control Gear “ECG”.
SOC 1/32W
220 - 240V , 50 / 60 Hz
Voltage / Frequency
“Other Voltages upon request”

1[22 mm ‘ hole on top.


Cable Entry
“E[tra knock-out holes upon request”
L H
22, 32 40 watt T8/T26 Circular Fluorescent for Normal Start “NS”, Electronic Start “DEOS” or Electronic High Frequency
“HF” Ballast “EB”.
Lamps 22, 40 55 watt FC T5/T16 Circular Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
“Other lamps (T5/T16 – T8/T26 – T12/T38 – TCL - TC-DE – TC-TE) upon request ¿tting housing dimensions subMect to
changes accordingly”

3 Hours duration Emergency Unit “EMU” with battery pack Maintained “/M” or Non-Maintained “/NM” for one lamp,
Emergency Unit and for various lamp types and voltage networks combinations.
“Additional Emergency Units to operate more than one lamp on request”

80
Recessed Mounted Luminaire
Recessed Flat Sheet Opal / Prismatic Recessed Louvers

LAY-IN OPAL LAY-IN FLAT HINGED FRAME FLAT HINGED FRAME WHITE PLASTIC SILVER PLASTIC GOLDEN PLASTIC METALIZED PLASTIC
PRISMATIC OPAL PRISMATIC LOUVERS LOUVERS LOUVERS LOUVERS

NO 86-87 NP 88-89 TO 90-91 TP 92-93 TL 124-125 TLS 126-127 TLG 128-129 NRI 130-131

Recessed Drop Opal / Prismatic Recessed Indirect

DROP OPAL DROP PRISMATIC MELLOW TWIN MELLOW

DO 94-95 DP 96-97 RCE 132-133 RT 134-135

Recessed Louvers Recessed Hygienic

ALUMINIUM MATT ALUMINIUM WHITE STEEL ALUMINIUM HYGIENIC OPAL HYGIENIC PRISMATIC HYGIENIC ALUMINIUM HYGIENIC PLAIN
V-LOUVERS V-LOUVERS V-LOUVERS V-LOUVERS V-LOUVERS ALUMINIUM V-LOUVERS

NA 98-99 NS 100-101 NW 102-103 VA 104-105 TOH 136-137 TPH 138-139 VAH 140-141 VSH 142-143

MATT ALUMINIUM WHITE STEEL DOUBLE PARABOLIC DOUBLE PARABOLIC HYGIENIC WHITE
V-LOUVERS V-LOUVERS MATT ALUMINIUM0 SPECULAR ALUMINIUM STEEL V-LOUVERS
LOUVERS LOUVERS

VS 106-107 VW 108-109 DPM 110-111 DPS 112-113 VWH 144-145

DEEP DOUBLE PARA- T5 SPECULAR


WHITE PLASTIC SILVER PLASTIC
BOLIC SEMI-SPECULAR
LOUVERS LOUVERS
ALUMINIUM LOUVERS

Recessed Mounted - Strip Ceiling


DDP 114-115 R5S 116-117 NL 118-119 NLS 120-121

PANEL OPAL PANEL PRISMATIC PANEL WHITE DISHED


GOLDEN PLASTIC
PLATE
LOUVERS

NLG 122-123 POC 146-147 PPC 148-149 PWC 150-151


Lay-In Flat Opal
SERIES : NOM/NOI
IP40
Technical Data
To Order : follow the sequence mr+gt+ht - ln / ls – cgt – vh – cgm – emu
Physical Characteristics

Model Reference

Frequency

Accessories
Grid Type

Emergency
Voltage
Lamp

Optional
Housing

Size
Number

Control
UC

Power
Factor
Lamp
H

Gear
Type

Type

/
M I U

Unit
(Universal
(Metric) (Imperial) (Universal)
Compact)
L W L W L W L W T8 T5
mm mm mm mm mm mm mm mm mm mm watt v / Hz
595 293 605 300 620 315 1
14
595 293 605 300 620 315 2 17
595 595 605 605 620 620 3 18
None NS
standard) 24
595 595 605 605 620 620 4 Normal
plastic FTB
Start
1195 293 1215 300 1230 315 (end-caps 1 Fused
28
Terminal
1195 293 1215 300 1230 315 2 32 Block
1195 595 1215 605 1230 620 3 36 DEOS
3/NM
54 Electronic HPF
1195 595 1215 605 1230 620 4 3 hours
Starter High
- - 80 70 G TRW Non-
1495 293 1515 300 1530 315 1 Power
for CRS) Temperature Maintained
35 220 - 240V Factor
(end-bo[ Resistant
NP 1495 293 1515 300 1530 315 2 49 Wire
EB
1495 595 1515 605 1530 620 3 58 Electronic 50 / 60 Hz
80 High
1495 595 1515 605 1530 620 4 3/M
Frequency HF
TW 3 hours
595 293 605 300 620 315 1 High
Through Maintained
36L Frequency
Wire
595 293 605 300 620 315 2 40L
Applications Suitable to be used in: of¿ces, clinics, education premises, circulation area general indoor application. EBD
595 595 605 605 620 620 3 55L Dimmable
80L Electronic
595 595 605 605 620 620 CRS 4
Made of press welded Cold Rolled Steel “CRS” sheet of tight construction to prevent light leakage, all metal parts pre-treated end-bo[
High
with a full degreasing and phosphate process, painted in stove enameled white baked epo[y polyester mi[-powder to ensure 11L Frequency
Housing 18L/D/T
high reÀectance of painted surfaces. 1
Other color ¿nishes upon request. 26D/T
- - - - - - 312 312 90
32T
2 42T
Standard opal Àat diffuser secured in an e[truded aluminum frame ¿nished in satin white. Frame is held to the body by means 70T
Light Controller
of special springs allowing easy opening and diffuser suspension during maintenance.

Mounting Recessed lay-in or universal. Suitable for ¿[ in Metric or Imperial or Universal Concealed standard T-pro¿le false ceiling.
Photometrics & Dimensions
High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.
Control Gear High Frequency Electronic Control Gear “ECG”.
High Frequency Dimmable Electronic Control Gear “ECG”.
NO 4/36W
220 - 240V , 50 / 60 Hz
Voltage / Frequency
“Other Voltages upon request”

1[22 mm ‘ hole on top.


Cable Entry
“E[tra knock-out holes upon request”
18, 36 58 watt T8/T26 Fluorescent for Normal Start “NS”, Electronic Start “DEOS” or Electronic High Frequency
“HF” Ballast “EB”.
17 32 watt T8 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
Lamps 14, 28 35 watt FH T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
24, 49, 54 80 watt F4 T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”. “Other lamps (T5/T16
– T8/T26 – T12/T38 – TCL – TC-D – TC-DE – TC-TE) upon request ¿tting housing dimensions subMect to changes
accordingly”

3 Hours duration Emergency Unit “EMU” with battery pack Maintained “/M” or Non-Maintained “/NM” for one lamp,
Emergency Unit and for various lamp types and voltage networks combinations.
“Additional Emergency Units to operate more than one lamp on request”

86
Lay-In Flat Prismatic
SERIES : NPM/NPI IP40
Technical Data
To Order : follow the sequence mr+gt+ht - ln / ls – cgt – vh – cgm – emu
Physical Characteristics

Model Reference

Frequency

Accessories
Grid Type

Emergency
Voltage
Lamp

Optional
Housing

Size
Number

Control
UC

Power
Factor
Lamp
H

Gear
Type

Type

/
M I U

Unit
(Universal
(Metric) (Imperial) (Universal)
Compact)
L W L W L W L W T8 T5
mm mm mm mm mm mm mm mm mm mm watt v / Hz
595 293 605 300 620 315 1
14
595 293 605 300 620 315 2 17
595 595 605 605 620 620 3 18
None NS
standard) 24
595 595 605 605 620 620 4 Normal
plastic FTB
Start
1195 293 1215 300 1230 315 (end-caps 1 Fused
28
Terminal
1195 293 1215 300 1230 315 2 32 Block
1195 595 1215 605 1230 620 3 36 DEOS
3/NM
54 Electronic HPF
1195 595 1215 605 1230 620 4 3 hours
Starter High
- - 80 70 G TRW Non-
1495 293 1515 300 1530 315 1 Power
for CRS) Temperature Maintained
35 220 - 240V Factor
(end-bo[ Resistant
NP 1495 293 1515 300 1530 315 2 49 Wire
EB
1495 595 1515 605 1530 620 3 58 Electronic 50 / 60 Hz
80 High
1495 595 1515 605 1530 620 4 3/M
Frequency HF
TW 3 hours
595 293 605 300 620 315 1 High
Through Maintained
36L Frequency
Wire
595 293 605 300 620 315 2 40L
EBD
Applications Suitable to be used in: of¿ces, clinics, education premises, circulation area general indoor application. 595 595 605 605 620 620 3 55L Dimmable
80L Electronic
595 595 605 605 620 620 CRS 4
Made of press welded Cold Rolled Steel “CRS” sheet of tight construction to prevent light leakage, all metal parts High
end-bo[
pre-treated with a full degreasing and phosphate process, painted in stove enameled white baked epo[y polyester mi[- 11L Frequency
Housing 1 18L/D/T
powder to ensure high reÀectance of painted surfaces.
26D/T
Other color ¿nishes upon request. - - - - - - 312 312 90
32T
2 42T
Standard Prismatic Àat diffuser secured in an e[truded aluminum frame ¿nished in satin white. Frame is held to the 70T
Light Controller
body by means of special springs allowing easy opening and diffuser suspension during maintenance.

Recessed lay-in or universal. Suitable for ¿[ in Metric or Imperial or Universal Concealed standard T-pro¿le false ceil-
Mounting
ing.
Photometrics & Dimensions
High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.
Control Gear High Frequency Electronic Control Gear “ECG”.
High Frequency Dimmable Electronic Control Gear “ECG”.
NP 4/18W
220 - 240V , 50 / 60 Hz
Voltage / Frequency
“Other Voltages upon request”

1[22 mm ‘ hole on top.


Cable Entry
“E[tra knock-out holes upon request”
18, 36 58 watt T8/T26 Fluorescent for Normal Start “NS”, Electronic Start “DEOS” or Electronic High
Frequency “HF” Ballast “EB”.
17 32 watt T8 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
Lamps 14, 28 35 watt FH T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
24, 49, 54 80 watt F4 T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”. “Other lamps
(T5/T16 – T8/T26 – T12/T38 – TCL – TC-D – TC-DE – TC-TE) upon request ¿tting housing dimensions
subMect to changes accordingly”

3 Hours duration Emergency Unit “EMU” with battery pack Maintained “/M” or Non-Maintained “/NM” for one
Emergency Unit lamp, and for various lamp types and voltage networks combinations.
“Additional Emergency Units to operate more than one lamp on request”

88
Hinged Frame Flat Opal
SERIES : TOM/TOI/TOC/TOCM IP40
Technical Data
To Order : follow the sequence mr+gt+ht - ln / ls – cgt – vh – cgm - emu
Physical Characteristics

Model Reference

Frequency

Accessories

Emergency
Grid Type

Voltage
Lamp

Optional
Housing

Size
Number

Control

Power
Factor
Lamp

Gear
Type

Type

/
CM

Unit
M I C
(concealed
(metric) (imperial) (concealed)
metric)
L W L W L W L W H
mm mm mm mm mm mm mm mm mm watt V / Hz

595 295 605 300 624 324 600 300 1


14
595 295 605 300 624 324 600 300 2 17

595 595 605 605 624 624 600 600 3 18 NS


24 Normal
Start FTB
595 595 605 605 624 624 600 600 4
None Fused
(standard Terminal
1195 295 1215 300 1226 324 1200 300 1 Block
plastic
28 DEOS
end-caps)
1195 295 1215 300 1226 324 1200 300 2 32 Electronic
3/NM
Starter HPF
1195 595 1215 605 1226 624 1200 600 3 36 3 hours
High TRW
54 Non-
G Power Temperature
1195 595 1215 605 1226 624 1200 600 4
220 - 240V Maintained
(for CRS Factor Resistant
TO 100 end-bo[) Wire
1495 295 1515 300 1526 324 1500 300 1 EB
Electronic 50 / 60 Hz
35 3/M
1495 295 1515 300 1526 324 1500 300 2 High HF
49 3 hours
Frequency High TW
Maintained
1495 595 1515 605 1526 624 1500 600 3 58 Frequency Through
80 Wire
Applications Suitable to be used in: of¿ces, clinics, education premises, circulation area general indoor application. 1495 595 1515 605 1526 624 1500 600 4
EBD
Dimmable
595 295 605 300 624 324 600 300 1
Electronic
Made of press welded Cold Rolled Steel “CRS” sheet of tight construction to prevent light leakage, all metal parts 36L High
pre-treated with a full degreasing and phosphate process, painted in stove enameled white baked epo[y polyester mi[- 595 295 605 300 624 324 600 300 2
Housing CRS 40L Frequency
powder to ensure high reÀectance of painted surfaces.
end-bo[ 55L
Other color ¿nishes upon request. 595 595 605 605 624 624 600 600 3
80L
Standard opal Àat diffuser secured in an e[truded aluminum frame ¿nished in satin white. Frame is held to the body by 595 595 605 605 624 624 600 600 4
Light Controller means of special hinges and latches allow easy opening and diffuser suspension during maintenance. A special gasket
led on the back of the frame reduces penetration of dust particles.
Recessed lay-in or universal. Suitable for ¿[ in Metric or Imperial or Universal Concealed standard T-pro¿le false ceil-
Mounting
ing.
Photometrics & Dimensions
High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.
Control Gear High Frequency Electronic Control Gear “ECG”.
High Frequency Dimmable Electronic Control Gear “ECG”.
TO 4/18W
220 - 240V , 50 / 60 Hz
Voltage / Frequency
“Other Voltages upon request”

1[22 mm ‘ hole on top.


Cable Entry
“E[tra knock-out holes upon request”
18, 36 58 watt T8/T26 Fluorescent for Normal Start “NS”, Electronic Start “DEOS” or Electronic High
Frequency “HF” Ballast “EB”.
17 32 watt T8 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
Lamps 14, 28 35 watt FH T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
24, 49, 54 80 watt F4 T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”. “Other lamps
(T5/T16 – T8/T26 – T12/T38 – TCL – TC-D – TC-DE – TC-TE) upon request ¿tting housing dimensions
subMect to changes accordingly”

3 Hours duration Emergency Unit “EMU” with battery pack Maintained “/M” or Non-Maintained “/NM” for one
Emergency Unit lamp, and for various lamp types and voltage networks combinations.
“Additional Emergency Units to operate more than one lamp on request”

90
Hinged Frame Flat Prismatic
SERIES : TPM/TPI/TPC/TPCM
IP40
Technical Data
To Order : follow the sequence mr+gt+ht - ln / ls – cgt – vh – cgm - emu
Physical Characteristics

Model Reference

Frequency

Accessories
Grid Type

Emergency
Voltage
Lamp
Housing

Size
Number

Control

Power
Factor
CM

Lamp

Gear
Type

Type

Unit
M I C
(concealed
(metric) (imperial) (concealed)
metric)
L W L W L W L W H
mm mm mm mm mm mm mm mm mm watt V / Hz

595 295 605 300 624 324 600 300 1


14
595 295 605 300 624 324 600 300 2 17

595 595 605 605 624 624 600 600 3 18 NS


24 Normal
Start FTB
595 595 605 605 624 624 600 600 4
None Fused
(standard Terminal
1195 295 1215 300 1226 324 1200 300 1 Block
plastic
28 DEOS
end-caps)
1195 295 1215 300 1226 324 1200 300 2 32 Electronic
3/NM
Starter HPF
1195 595 1215 605 1226 624 1200 600 3 36 3 hours
High TRW
54 Non-
G Power Temperature
1195 595 1215 605 1226 624 1200 600 4
220 - 240V Maintained
(for CRS Factor Resistant
TP 100 end-bo[) Wire
1495 295 1515 300 1526 324 1500 300 1 EB
Electronic 50 / 60 Hz
35 3/M
1495 295 1515 300 1526 324 1500 300 2 High HF
49 3 hours
Frequency High TW
58 Maintained
1495 595 1515 605 1526 624 1500 600 3 Frequency Through
80 Wire
Applications Suitable to be used in: of¿ces, clinics, education premises, circulation area general indoor application. 1495 595 1515 605 1526 624 1500 600 4
EBD
Dimmable
595 295 605 300 624 324 600 300 1
Made of press welded Cold Rolled Steel “CRS” sheet of tight construction to prevent light leakage, all metal parts Electronic
36L High
pre-treated with a full degreasing and phosphate process, painted in stove enameled white baked epo[y polyester mi[-
Housing 595 295 605 300 624 324 600 300 2 40L Frequency
powder to ensure high reÀectance of painted surfaces. CRS
Other color ¿nishes upon request. end-bo[ 55L
595 595 605 605 624 624 600 600 3
80L
Standard prismatic Àat diffuser secured in an e[truded aluminum frame ¿nished in satin white. Frame is held to the
595 595 605 605 624 624 600 600 4
Light Controller body by means of special hinges and latches allow easy opening and diffuser suspension during maintenance. A
special gasket led on the back of the frame reduces penetration of dust particles

Mounting Recessed lay-in or concealed. Suitable for ¿[ in Metric or Imperial or Concealed standard T-pro¿le false ceiling.
Photometrics & Dimensions
High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.
Control Gear High Frequency Electronic Control Gear “ECG”.
High Frequency Dimmable Electronic Control Gear “ECG”.
TP 4/18W
220 - 240V , 50 / 60 Hz
Voltage / Frequency
“Other Voltages upon request”

1[22 mm ‘ hole on top.


Cable Entry
“E[tra knock-out holes upon request”
18, 36 58 watt T8/T26 Fluorescent for Normal Start “NS”, Electronic Start “DEOS” or Electronic High
Frequency “HF” Ballast “EB”.
17 32 watt T8 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
Lamps 14, 28 35 watt FH T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
24, 49, 54 80 watt F4 T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”. “Other lamps
(T5/T16 – T8/T26 – T12/T38 – TCL – TC-D – TC-DE – TC-TE) upon request ¿tting housing dimensions
subMect to changes accordingly”

3 Hours duration Emergency Unit “EMU” with battery pack Maintained “/M” or Non-Maintained “/NM” for one
Emargency Unit lamp, and for various lamp types and voltage networks combinations.
“Additional Emergency Units to operate more than one lamp on request”

92
Drop Opal
SERIES : DOM/DOI/DOC/DOCM
IP53
Technical Data
To Order : follow the sequence mr+gt+ht - ln / ls – cgt – vh – cgm - emu
Physical Characteristics

Model Reference

Frequency

Accessories
Grid Type

Emergency
Voltage
Lamp

Optional
Housing

Size
Number

Control

Power
Factor
CM

Lamp

Gear
Type

Type

Unit
M I C
concealed)
(metric) (imperial) (concealed)
(metric
L W L W L W L W H
mm mm mm mm mm mm mm mm mm watt V / Hz

595 295 605 300 624 324 600 300 1


14
595 295 605 300 624 324 600 300 2 17

595 595 605 605 624 624 600 600 3 18 NS


24 Normal
Start FTB
595 595 605 605 624 624 600 600 4
None Fused
standard) Terminal
1195 295 1215 300 1226 324 1200 300 1 Block
plastic
28 DEOS
(end-caps
1195 295 1215 300 1226 324 1200 300 2 32 Electronic
NM/3
Starter
1195 595 1215 605 1226 624 1200 600 3 36 HPF hours 3
TRW
54 High Non-
G Temperature
1195 595 1215 605 1226 624 1200 600 4
220 - 240V Power Maintained
for CRS) Resistant
Factor
DO 100 (end-bo[ Wire
1495 295 1515 300 1526 324 1500 300 1 EB
Electronic 50 / 60 Hz
35 M/3
1495 295 1515 300 1526 324 1500 300 2 High
49 HF hours 3
Frequency TW
High Maintained
1495 595 1515 605 1526 624 1500 600 3 58 Through
Frequency
80 Wire
Applications Suitable to be used in: of¿ces, clinics, education premises, circulation area general indoor application. 1495 595 1515 605 1526 624 1500 600 4
EBD
Dimmable
595 295 605 300 624 324 600 300 1
Made of press welded Cold Rolled Steel “CRS” sheet of tight construction to prevent light leakage, all metal parts Electronic
36L High
pre-treated with a full degreasing and phosphate process, painted in stove enameled white baked epo[y polyester mi[- 595 295 605 300 624 324 600 300 2
Housing CRS 40L Frequency
powder to ensure high reÀectance of painted surfaces.
Other color ¿nishes upon request. end-bo[ 55L
595 595 605 605 624 624 600 600 3
80L
Drop opal metacrylate diffuser with strong e[truded sides Frame is held to the body by means of special springs allow- 595 595 605 605 624 624 600 600 4
Light Controller ing easy opening and diffuser suspension during maintenance.

Mounting Recessed lay-in or concealed. Suitable for ¿[ in Metric or Imperial or Concealed standard T-pro¿le false ceiling.
Photometrics & Dimensions
High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.
Control Gear High Frequency Electronic Control Gear “ECG”.
High Frequency Dimmable Electronic Control Gear “ECG”.
DO 4/18W
220 - 240V , 50 / 60 Hz
Voltage / Frequency
“Other Voltages upon request”

1[22 mm ‘ hole on top.


Cable Entry
“E[tra knock-out holes upon request”
18, 36 58 watt T8/T26 Fluorescent for Normal Start “NS”, Electronic Start “DEOS” or Electronic High
Frequency “HF” Ballast “EB”.
17 32 watt T8 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
Lamps 14, 28 35 watt FH T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
24, 49, 54 80 watt F4 T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”. “Other lamps
(T5/T16 – T8/T26 – T12/T38 – TCL – TC-D – TC-DE – TC-TE) upon request ¿tting housing dimensions
subMect to changes accordingly”

3 Hours duration Emergency Unit “EMU” with battery pack Maintained “/M” or Non-Maintained “/NM” for one
Emergency Unit lamp, and for various lamp types and voltage networks combinations.
“Additional Emergency Units to operate more than one lamp on request”

94
Drop Prismatic
SERIES : DPM/DPI/DPC/DPCM
IP53
Technical Data
To Order : follow the sequence mr+gt+ht - ln / ls – cgt – vh – cgm - emu
Physical Characteristics

Model Reference

Frequency

Accessories
Grid Type

Emergency
Voltage
Lamp

Optional
Housing

Size
Number

Control

Power
Factor
Lamp
CM

Gear
Type

Type

Unit
M I C
(concealed
(metric) (imperial) (concealed)
metric)
L W L W L W L W H
mm mm mm mm mm mm mm mm mm watt V / Hz

595 295 605 300 624 324 600 300 1


14
595 295 605 300 624 324 600 300 2 17

595 595 605 605 624 624 600 600 3 18 NS


24 Normal
Start FTB
595 595 605 605 624 624 600 600 4
None Fused
standard) Terminal
1195 295 1215 300 1226 324 1200 300 1 Block
plastic
28 DEOS
(end-caps
1195 295 1215 300 1226 324 1200 300 2 32 Electronic
3/NM
Starter HPF
1195 595 1215 605 1226 624 1200 600 3 36 3 hours
High TRW
54 Non-
G Power Temperature
1195 595 1215 605 1226 624 1200 600 4
220 - 240V Maintained
for CRS) Factor Resistant
DP 100 (end-bo[ Wire
1495 295 1515 300 1526 324 1500 300 1 EB
Electronic 50 / 60 Hz
35 3/M
1495 295 1515 300 1526 324 1500 300 2 High HF
49 3 hours
Frequency High TW
58 Maintained
1495 595 1515 605 1526 624 1500 600 3 Frequency Through
80 Wire
Applications Suitable to be used in: of¿ces, clinics, education premises, circulation area general indoor application. 1495 595 1515 605 1526 624 1500 600 4
EBD
Dimmable
595 295 605 300 624 324 600 300 1
Electronic
Made of press welded Cold Rolled Steel “CRS” sheet of tight construction to prevent light leakage, all metal parts 36L High
pre-treated with a full degreasing and phosphate process, painted in stove enameled white baked epo[y polyester mi[- 595 295 605 300 624 324 600 300 2 Frequency
Housing CRS 40L
powder to ensure high reÀectance of painted surfaces.
end-bo[ 55L
Other color ¿nishes upon request. 595 595 605 605 624 624 600 600 3
80L
595 595 605 605 624 624 600 600 4
Drop prismatic metacrylate diffuser with strong e[truded sides Frame is held to the body by means of special springs
Light Controller
allowing easy opening and diffuser suspension during maintenance.

Mounting Recessed lay-in or concealed. Suitable for ¿[ in Metric or Imperial or Concealed standard T-pro¿le false ceiling.
Photometrics & Dimensions
High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.
Control Gear High Frequency Electronic Control Gear “ECG”.
High Frequency Dimmable Electronic Control Gear “ECG”.
DP 4/36W
220 - 240V , 50 / 60 Hz
Voltage / Frequency
“Other Voltages upon request”

1[22 mm ‘ hole on top.


Cable Entry
“E[tra knock-out holes upon request”
18, 36 58 watt T8/T26 Fluorescent for Normal Start “NS”, Electronic Start “DEOS” or Electronic High
Frequency “HF” Ballast “EB”.
17 32 watt T8 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
Lamps 14, 28 35 watt FH T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
24, 49, 54 80 watt F4 T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”. “Other lamps
(T5/T16 – T8/T26 – T12/T38 – TCL – TC-D – TC-DE – TC-TE) upon request ¿tting housing dimensions
subMect to changes accordingly”

3 Hours duration Emergency Unit “EMU” with battery pack Maintained “/M” or Non-Maintained “/NM” for one
Emergency Unit lamp, and for various lamp types and voltage networks combinations.
“Additional Emergency Units to operate more than one lamp on request”

96
Aluminium V-Louvers
SERIES : NAM/NAI
IP20
Technical Data
To Order : follow the sequence mr+gt+ht - ln / ls – cgt – vh – cgm – emu
Physical Characteristics

Model Reference

Frequency

Accessories
Grid Type

Emergency
Voltage
Lamp

Optional
Housing

Size
Number

Control

Power
Factor
UC

Lamp

Gear
Type

Type

/
H

Unit
M I U
(Universal
(Metric) (Imperial) (Universal)
Compact)
L W L W L W L W T8 T5
mm mm mm mm mm mm mm mm mm mm watt v / Hz
595 293 605 300 620 315 1
14
595 293 605 300 620 315 2 17
595 595 605 605 620 620 3 18
None
(standard 24
595 595 605 605 620 620 4 NS
plastic
Normal FTB
1195 293 1215 300 1230 315 end-caps) 1 28 Start Fused
1195 293 1215 300 1230 315 2 32 Terminal
Block
1195 595 1215 605 1230 620 3 36
54 DEOS 3/NM
1195 595 1215 605 1230 620 4 HPF
Electronic 3 hours
- - 80 70 G High
1495 293 1515 300 1530 315 1 Starter TRW Non-
(for CRS 35 Power
Temperature Maintained
end-bo[) 220 - 240V Factor
1495 293 1515 300 1530 315 2 49 Resistant
NA Wire
1495 595 1515 605 1530 620 3 58 Electronic
80 High 50 / 60 Hz
1495 595 1515 605 1530 620 4 Frequency 3/M
HF
595 293 605 300 620 315 1 TW 3 hours
High
36L Through Maintained
Frequency
595 293 605 300 620 315 2 40L Wire
EBD
Applications Suitable to be used in: of¿ces, clinics, education premises, circulation area general indoor application. 595 595 605 605 620 620 3 55L Dimmable
80L Electronic
595 595 605 605 620 620 CRS 4 High
Made of press welded Cold Rolled Steel “CRS” sheet of tight construction to prevent light leakage, all metal parts end-bo[ Frequency
pre-treated with a full degreasing and phosphate process, painted in stove enameled white baked epo[y polyester mi[- 11L
Housing 1 18L/D/T
powder to ensure high reÀectance of painted surfaces.
Other color ¿nishes upon request. 26D/T
- - - - - - 312 312 90
32T
2 42T
V shaped specular anodized aluminum louvers, with strip plain aluminum cross-bafÀe. Louvers are held to the body by 70T
Light Controller
means of special steel springs.

Recessed lay-in or universal. Suitable for ¿[ in Metric or Imperial or Universal Concealed standard T-pro¿le false ceil-
Mounting
ing.
Photometrics & Dimensions
High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.
Control Gear High Frequency Electronic Control Gear “ECG”.
High Frequency Dimmable Electronic Control Gear “ECG”.
NA 4/18W
220 - 240V , 50 / 60 Hz
Voltage / Frequency
“Other Voltages upon request”

1[22 mm ‘ hole on top.


Cable Entry
“E[tra knock-out holes upon request”
18, 36 58 watt T8/T26 Fluorescent for Normal Start “NS”, Electronic Start “DEOS” or Electronic High
Frequency “HF” Ballast “EB”.
17 32 watt T8 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
Lamps 14, 28 35 watt FH T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
24, 49, 54 80 watt F4 T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”. “Other lamps
(T5/T16 – T8/T26 – T12/T38 – TCL – TC-D – TC-DE – TC-TE) upon request ¿tting housing dimensions
subMect to changes accordingly”

3 Hours duration Emergency Unit “EMU” with battery pack Maintained “/M” or Non-Maintained “/NM” for one
Emergency Unit lamp, and for various lamp types and voltage networks combinations.
“Additional Emergency Units to operate more than one lamp on request”

98
Matt Aluminium V-Louvers
SERIES : NSM/NSI
IP20
Technical Data
To Order : follow the sequence mr+gt+ht - ln / ls – cgt – vh – cgm – emu
Physical Characteristics

Model Reference

Frequency

Accessories
Grid Type

Emergency
Voltage
Lamp

Optional
Housing

Size
Number

Control

Power
Factor
UC

Lamp

Gear
Type

Type

/
H

Unit
M I U
(Universal
(Metric) (Imperial) (Universal)
Compact)
L W L W L W L W T8 T5
mm mm mm mm mm mm mm mm mm mm watt v / Hz
595 293 605 300 620 315 1
14
595 293 605 300 620 315 2 17
595 595 605 605 620 620 3 18
None
(standard 24
595 595 605 605 620 620 4 NS
plastic
Normal FTB
1195 293 1215 300 1230 315 end-caps) 1 28 Start Fused
1195 293 1215 300 1230 315 2 32 Terminal
Block
1195 595 1215 605 1230 620 3 36
54 DEOS 3/NM
1195 595 1215 605 1230 620 4 HPF
Electronic 3 hours
- - 80 70 G High
1495 293 1515 300 1530 315 1 Starter TRW Non-
(for CRS 35 Power
Temperature Maintained
end-bo[) 220 - 240V Factor
1495 293 1515 300 1530 315 2 49 Resistant
NA Wire
1495 595 1515 605 1530 620 3 58 Electronic
80 High 50 / 60 Hz
1495 595 1515 605 1530 620 4 Frequency 3/M
HF
595 293 605 300 620 315 1 TW 3 hours
High
36L Through Maintained
Frequency
595 293 605 300 620 315 2 40L Wire
EBD
Applications Suitable to be used in: of¿ces, clinics, education premises, circulation area general indoor application. 595 595 605 605 620 620 3 55L Dimmable
80L Electronic
595 595 605 605 620 620 CRS 4 High
Made of press welded Cold Rolled Steel “CRS” sheet of tight construction to prevent light leakage, all metal parts end-bo[ Frequency
pre-treated with a full degreasing and phosphate process, painted in stove enameled white baked epo[y polyester mi[- 11L
Housing 1 18L/D/T
powder to ensure high reÀectance of painted surfaces.
Other color ¿nishes upon request. 26D/T
- - - - - - 312 312 90
32T
2 42T
V shaped matt anodized aluminum louvers, with strip plain aluminum cross-bafÀe. Louvers are held to the body by 70T
Light Controller
means of special steel springs.

Recessed lay-in or universal. Suitable for ¿[ in Metric or Imperial or Universal Concealed standard T-pro¿le false ceil-
Mounting
ing.
Photometrics & Dimensions
High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.
Control Gear High Frequency Electronic Control Gear “ECG”.
High Frequency Dimmable Electronic Control Gear “ECG”.
NS 4/36W
220 - 240V , 50 / 60 Hz
Voltage / Frequency
“Other Voltages upon request”

1[22 mm ‘ hole on top.


Cable Entry
“E[tra knock-out holes upon request”
18, 36 58 watt T8/T26 Fluorescent for Normal Start “NS”, Electronic Start “DEOS” or Electronic High
Frequency “HF” Ballast “EB”.
17 32 watt T8 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
Lamps 14, 28 35 watt FH T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
24, 49, 54 80 watt F4 T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”. “Other lamps
(T5/T16 – T8/T26 – T12/T38 – TCL – TC-D – TC-DE – TC-TE) upon request ¿tting housing dimensions
subMect to changes accordingly”

3 Hours duration Emergency Unit “EMU” with battery pack Maintained “/M” or Non-Maintained “/NM” for one
Emergency Unit lamp, and for various lamp types and voltage networks combinations.
“Additional Emergency Units to operate more than one lamp on request”

100
White Steel V-Louvers
SERIES : NWM/NWI
IP20
Technical Data
To Order : follow the sequence mr+gt+ht - ln / ls – cgt – vh – cgm – emu
Physical Characteristics

Model Reference

Frequency

Accessories
Grid Type

Emergency
Voltage
Lamp

Optional
Housing

Size
Number

Control

Power
Factor
UC

Lamp

Gear
Type

Type

/
H

Unit
M I U
(Universal
(Metric) (Imperial) (Universal)
Compact)
L W L W L W L W T8 T5
mm mm mm mm mm mm mm mm mm mm watt v / Hz
595 293 605 300 620 315 1
14
595 293 605 300 620 315 2 17
595 595 605 605 620 620 3 18
None
(standard 24
595 595 605 605 620 620 4 NS
plastic
Normal FTB
1195 293 1215 300 1230 315 end-caps) 1 28 Start Fused
1195 293 1215 300 1230 315 2 32 Terminal
Block
1195 595 1215 605 1230 620 3 36
54 DEOS 3/NM
1195 595 1215 605 1230 620 4 HPF
Electronic 3 hours
- - 80 70 G High
1495 293 1515 300 1530 315 1 Starter TRW Non-
(for CRS 35 Power
Temperature Maintained
end-bo[) 220 - 240V Factor
1495 293 1515 300 1530 315 2 49 Resistant
NA Wire
1495 595 1515 605 1530 620 3 58 Electronic
80 High 50 / 60 Hz
1495 595 1515 605 1530 620 4 Frequency 3/M
HF
595 293 605 300 620 315 1 TW 3 hours
High
36L Through Maintained
Frequency
595 293 605 300 620 315 2 40L Wire
EBD
Applications Suitable to be used in: of¿ces, clinics, education premises, circulation area general indoor application. 595 595 605 605 620 620 3 55L Dimmable
80L Electronic
595 595 605 605 620 620 CRS 4 High
Made of press welded Cold Rolled Steel “CRS” sheet of tight construction to prevent light leakage, all metal parts end-bo[ Frequency
11L
Housing pre-treated with a full degreasing and phosphate process, painted in stove enameled white baked epo[y polyester mi[- 1 18L/D/T
powder to ensure high reÀectance of painted surfaces. Other color ¿nishes upon request. 26D/T
- - - - - - 312 312 90
32T
2 42T
V shaped steel sheets louvers, with strip cross-bafÀe all painted white. Louvers are held to the body by means 70T
Light Controller
of special steel springs.

Recessed lay-in or universal. Suitable for ¿[ in Metric or Imperial or Universal Concealed standard T-pro¿le
Mounting
false ceiling.
Photometrics & Dimensions
High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.
Control Gear High Frequency Electronic Control Gear “ECG”.
High Frequency Dimmable Electronic Control Gear “ECG”.
NW 4/18W
220 - 240V , 50 / 60 Hz
Voltage / Frequency
“Other Voltages upon request”

1[22 mm ‘ hole on top.


Cable Entry
“E[tra knock-out holes upon request”
18, 36 58 watt T8/T26 Fluorescent for Normal Start “NS”, Electronic Start “DEOS” or Electronic High
Frequency “HF” Ballast “EB”.
17 32 watt T8 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
Lamps 14, 28 35 watt FH T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
24, 49, 54 80 watt F4 T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”. “Other lamps
(T5/T16 – T8/T26 – T12/T38 – TCL - TC-DE – TC-TE) upon request ¿tting housing dimensions subMect to
changes accordingly”

3 Hours duration Emergency Unit “EMU” with battery pack Maintained “/M” or Non-Maintained “/NM” for one
Emergency Unit lamp, and for various lamp types and voltage networks combinations. “Additional Emergency Units to operate
more than one lamp on request”

102
Aluminium V-Louvers
SERIES : VAM/VAI/VAC/VACM
IP20
Technical Data
To Order : follow the sequence mr+gt+ht - ln / ls – cgt – vh – cgm - emu
Physical Characteristics

Frequency

Accessories
Grid Type

Emergency
Voltage
Reference

Lamp

Optional
Housing

Size
Number

Control
CM

Power
Factor
Model

Lamp

Gear
Type

Type

Unit
M I C
(concealed
(metric) (imperial) (concealed)
metric)
L W L W L W L W H
mm mm mm mm mm mm mm mm mm watt V / Hz

595 295 605 300 624 324 600 300 1


14
595 295 605 300 624 324 600 300 2 17

595 595 605 605 624 624 600 600 3 18 NS


24 Normal
595 595 605 605 624 624 600 600 4 Start FTB
None Fused
standard) Terminal
1195 295 1215 300 1226 324 1200 300 1
plastic Block
28
(end-caps DEOS
1195 295 1215 300 1226 324 1200 300 2 32 Electronic 3/NM
HPF
36 Starter 3 hours
1195 595 1215 605 1226 624 1200 600 3 High
TRW Non-
54 Power
1195 595 1215 605 1226 624 1200 600
G
4
220 - 240V Factor
Temperature Maintained
for CRS) Resistant
VA 100
(end-bo[ EB Wire
1495 295 1515 300 1526 324 1500 300 1
35
Electronic 50 / 60 Hz
High 3/M
1495 295 1515 300 1526 324 1500 300 2 49 HF
Frequency 3 hours
High
58 TW Maintained
1495 595 1515 605 1526 624 1500 600 3 Frequency
Through
80
Wire
Applications Suitable to be used in: of¿ces, clinics, education premises, circulation area general indoor application. 1495 595 1515 605 1526 624 1500 600 4
EBD
Dimmable
595 295 605 300 624 324 600 300 1 Electronic
Made of press welded Cold Rolled Steel “CRS” sheet of tight construction to prevent light leakage, all metal parts 36L High
Housing pre-treated with a full degreasing and phosphate process, painted in stove enameled white baked epo[y polyester mi[- 595 295 605 300 624 324 600 300
CRS
2 40L Frequency
powder to ensure high reÀectance of painted surfaces. Other color ¿nishes upon request. end-bo[
595 595 605 605 624 624 600 600 3 55L
80L
V shaped specular anodized aluminum mirror louvers, with stepped surface strip aluminum cross-blades. 595 595 605 605 624 624 600 600 4
Light Controller
Louvers are held to the body by means of special steel springs.

Recessed lay-in or universal. Suitable for ¿[ in Metric or Imperial or Universal Concealed standard T-pro¿le
Mounting
false ceiling.
Photometrics & Dimensions
High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.
Control Gear High Frequency Electronic Control Gear “ECG”.
High Frequency Dimmable Electronic Control Gear “ECG”.
VA 4/18W
220 - 240V , 50 / 60 Hz
Voltage / Frequency
“Other Voltages upon request”

1[22 mm ‘ hole on top.


Cable Entry
“E[tra knock-out holes upon request”
18, 36 58 watt T8/T26 Fluorescent for Normal Start “NS”, Electronic Start “DEOS” or Electronic High
Frequency “HF” Ballast “EB”.
17 32 watt T8 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
Lamps 14, 28 35 watt FH T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
24, 49, 54 80 watt F4 T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”. “Other lamps
(T5/T16 – T8/T26 – T12/T38 – TCL - TC-DE – TC-TE) upon request ¿tting housing dimensions subMect to
changes accordingly”

3 Hours duration Emergency Unit “EMU” with battery pack Maintained “/M” or Non-Maintained “/NM” for one
Emergency Unit lamp, and for various lamp types and voltage networks combinations. “Additional Emergency Units to operate
more than one lamp on request”

104
Matt Aluminium V-Louvers
SERIES : VSM/VSI/VSC/VSCM
IP20
Technical Data
To Order : follow the sequence mr+gt+ht - ln / ls – cgt – vh – cgm - emu
Physical Characteristics

Frequency

Accessories
Grid Type

Emergency
Voltage
Reference

Lamp

Optional
Housing

Size
Number

Control

Power
Factor
Model
CM

Lamp

Gear
Type

Type

Unit
M I C
(concealed
(metric) (imperial) (concealed)
metric)
L W L W L W L W H
mm mm mm mm mm mm mm mm mm watt V / Hz

595 295 605 300 624 324 600 300 1


14
595 295 605 300 624 324 600 300 2 17

595 595 605 605 624 624 600 600 3 18 NS


24 Normal
Start FTB
595 595 605 605 624 624 600 600 4
None Fused
standard) Terminal
1195 295 1215 300 1226 324 1200 300 1 Block
plastic
28 DEOS
(end-caps
1195 295 1215 300 1226 324 1200 300 2 32 Electronic
3/NM
Starter HPF
1195 595 1215 605 1226 624 1200 600 3 36 3 hours
High TRW
54 Non-
G Power Temperature
1195 595 1215 605 1226 624 1200 600 4
220 - 240V Maintained
for CRS) Factor Resistant
VS 100 (end-bo[ Wire
1495 295 1515 300 1526 324 1500 300 1 EB
Electronic 50 / 60 Hz
35 3/M
1495 295 1515 300 1526 324 1500 300 2 High HF
49 3 hours
Frequency High TW
58 Maintained
1495 595 1515 605 1526 624 1500 600 3 Frequency Through
80 Wire
Applications Suitable to be used in: of¿ces, clinics, education premises, circulation area general indoor application. 1495 595 1515 605 1526 624 1500 600 4
EBD
Dimmable
595 295 605 300 624 324 600 300 1
Made of press welded Cold Rolled Steel “CRS” sheet of tight construction to prevent light leakage, all metal parts Electronic
36L High
Housing pre-treated with a full degreasing and phosphate process, painted in stove enameled white baked epo[y polyester mi[- 595 295 605 300 624 324 600 300 2
CRS 40L Frequency
powder to ensure high reÀectance of painted surfaces. Other color ¿nishes upon request.
end-bo[ 55L
595 595 605 605 624 624 600 600 3
80L
V shaped matt anodized aluminum louvers, with strip plain aluminum cross-bafÀe. Louvers are held to the body 595 595 605 605 624 624 600 600 4
Light Controller
by means of special steel springs.

Mounting Recessed lay-in or concealed. Suitable for ¿[ in Metric or Imperial or Concealed standard T-pro¿le false ceiling.
Photometrics & Dimensions
High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.
Control Gear High Frequency Electronic Control Gear “ECG”.
High Frequency Dimmable Electronic Control Gear “ECG”.
VS 4/18W
220 - 240V , 50 / 60 Hz
Voltage / Frequency
“Other Voltages upon request”

1[22 mm ‘ hole on top.


Cable Entry
“E[tra knock-out holes upon request”
18, 36 58 watt T8/T26 Fluorescent for Normal Start “NS”, Electronic Start “DEOS” or Electronic High
Frequency “HF” Ballast “EB”.
17 32 watt T8 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
Lamps 14, 28 35 watt FH T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
24, 49, 54 80 watt F4 T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”. “Other lamps
(T5/T16 – T8/T26 – T12/T38 – TCL - TC-DE – TC-TE) upon request ¿tting housing dimensions subMect to
changes accordingly”

3 Hours duration Emergency Unit “EMU” with battery pack Maintained “/M” or Non-Maintained “/NM” for one
Emergency Unit lamp, and for various lamp types and voltage networks combinations. “Additional Emergency Units to operate
more than one lamp on request”

106
White Steel V-Louvers
SERIES : VWM/VWI/VWC/VWCM
IP20
Technical Data
To Order : follow the sequence mr+gt+ht - ln / ls – cgt – vh – cgm - em
Physical Characteristics

Frequency

Accessories

Emergency
Grid Type

Voltage
Reference

Lamp

Optional
Housing

Size
Number

Control

Power
Factor
Model
CM

Lamp

Gear
Type

Type

Unit
M I C
(concealed
(metric) (imperial) (concealed)
metric)
L W L W L W L W H
mm mm mm mm mm mm mm mm mm watt V / Hz

595 295 605 300 624 324 600 300 1


14
595 295 605 300 624 324 600 300 2 17

595 595 605 605 624 624 600 600 3 18 NS


24 Normal
Start FTB
595 595 605 605 624 624 600 600 4
None Fused
(standard Terminal
1195 295 1215 300 1226 324 1200 300 1 Block
plastic
28 DEOS
end-caps)
1195 295 1215 300 1226 324 1200 300 2 32 Electronic
3/NM
Starter HPF
1195 595 1215 605 1226 624 1200 600 3 36 3 hours
High TRW
54 Non-
G Power Temperature
1195 595 1215 605 1226 624 1200 600 4
220 - 240V Maintained
(for CRS Factor Resistant
VW 100 end-bo[) Wire
1495 295 1515 300 1526 324 1500 300 1 EB
Electronic 50 / 60 Hz
35 3/M
1495 295 1515 300 1526 324 1500 300 2 High HF
49 3 hours
Frequency High TW
58 Maintained
1495 595 1515 605 1526 624 1500 600 3 Frequency Through
80 Wire
Applications Suitable to be used in: of¿ces, clinics, education premises, circulation area general indoor application. 1495 595 1515 605 1526 624 1500 600 4
EBD
Dimmable
595 295 605 300 624 324 600 300 1
Electronic
Made of press welded Cold Rolled Steel “CRS” sheet of tight construction to prevent light leakage, all metal parts 36L High
Housing pre-treated with a full degreasing and phosphate process, painted in stove enameled white baked epo[y polyester mi[- 595 295 605 300 624 324 600 300 2 40L Frequency
CRS
powder to ensure high reÀectance of painted surfaces. Other color ¿nishes upon request. end-bo[ 55L
595 595 605 605 624 624 600 600 3
80L
V shaped steel sheets louvers, with strip cross-bafÀe all painted white. Louvers are held to the body by means 595 595 605 605 624 624 600 600 4
Light Controller
of special steel springs.

Mounting Recessed lay-in or concealed. Suitable for ¿[ in Metric or Imperial or Concealed standard T-pro¿le false ceiling.
Photometrics & Dimensions
High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.
Control Gear High Frequency Electronic Control Gear “ECG”.
High Frequency Dimmable Electronic Control Gear “ECG”.
VW 4/18W
220 - 240V , 50 / 60 Hz
Voltage / Frequency
“Other Voltages upon request”

1[22 mm ‘ hole on top.


Cable Entry
“E[tra knock-out holes upon request”
18, 36 58 watt T8/T26 Fluorescent for Normal Start “NS”, Electronic Start “DEOS” or Electronic High
Frequency “HF” Ballast “EB”.
17 32 watt T8 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
Lamps 14, 28 35 watt FH T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
24, 49, 54 80 watt F4 T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”. “Other lamps
(T5/T16 – T8/T26 – T12/T38 – TCL - TC-DE – TC-TE) upon request ¿tting housing dimensions subMect to
changes accordingly”

3 Hours duration Emergency Unit “EMU” with battery pack Maintained “/M” or Non-Maintained “/NM” for one
Emergency Unit lamp, and for various lamp types and voltage networks combinations. “Additional Emergency Units to operate
more than one lamp on request”

108
Double Parabolic Matt Aluminium
Louver
SERIES : DPMM/DPMI/DPMC/DPMCM
IP20
Technical Data

To Order : follow the sequence mr+gt+ht - ln / ls – cgt – vh – cgm - emu


Physical Characteristics

Frequency

Accessories

Emergency
Voltage
Grid Type

Reference

Lamp

Optional
Housing

Size
Number

Control

Power
Factor
Model
CM

Lamp

Gear
Type

Type

Unit
M I C
(concealed
(metric) (imperial) (concealed)
metric)
L W L W L W L W H
mm mm mm mm mm mm mm mm mm watt V / Hz

595 295 605 300 624 324 600 300 1


14
595 295 605 300 624 324 600 300 2 17

595 595 605 605 624 624 600 600 3 18


NS
24 Normal
FTB
595 595 605 605 624 624 600 600 4 Start
None Fused
(standard Terminal
1195 295 1215 300 1226 324 1200 300 1 Block
plastic
28
end-caps) DEOS
1195 295 1215 300 1226 324 1200 300 2 32 Electronic 3/NM
HPF
1195 595 1215 605 1226 624 1200 600 3 36 Starter 3 hours
High TRW
54 Non-
G Power Temperature
1195 595 1215 605 1226 624 1200 600 4
220 - 240V Maintained
(for CRS Factor Resistant
DPM 110 end-bo[) Wire
EB
1495 295 1515 300 1526 324 1500 300 1 Electronic 50 / 60 Hz
35 High 3/M
1495 295 1515 300 1526 324 1500 300 2 HF
49 Frequency 3 hours
High TW
58 Maintained
1495 595 1515 605 1526 624 1500 600 3 Frequency Through
80 Wire
Applications Suitable to be used in: of¿ces, clinics, education premises, circulation area general indoor application. 1495 595 1515 605 1526 624 1500 600 4 EBD
Dimmable
595 295 605 300 624 324 600 300 1 Electronic
Made of press welded Cold Rolled Steel “CRS” sheet of tight construction to prevent light leakage, all metal parts 36L High
Housing pre-treated with a full degreasing and phosphate process, painted in stove enameled white baked epo[y polyester mi[- 595 295 605 300 624 324 600 300 2 Frequency
CRS 40L
powder to ensure high reÀectance of painted surfaces. Other color ¿nishes upon request.
end-bo[ 55L
595 595 605 605 624 624 600 600 3
80L
Double parabolic matt anodized aluminum louvers, with cut-off angle less than 60 . Louvers are held to the
o
595 595 605 605 624 624 600 600 4
Light Controller
body by means of special steel springs allowing easy opening and diffuser suspension during maintenance.

Mounting Recessed lay-in or concealed. Suitable for ¿[ in Metric or Imperial or Concealed standard T-pro¿le false ceiling.
Photometrics & Dimensions
High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.
Control Gear High Frequency Electronic Control Gear “ECG”.
High Frequency Dimmable Electronic Control Gear “ECG”.
DPM 4/18W
220 - 240V , 50 / 60 Hz
Voltage / Frequency
“Other Voltages upon request”

1[22 mm ‘ hole on top.


Cable Entry
“E[tra knock-out holes upon request”
18, 36 58 watt T8/T26 Fluorescent for Normal Start “NS”, Electronic Start “DEOS” or Electronic High
Frequency “HF” Ballast “EB”.
17 32 watt T8 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
Lamps 14, 28 35 watt FH T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
24, 49, 54 80 watt F4 T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”. “Other lamps
(T5/T16 – T8/T26 – T12/T38 – TCL - TC-DE – TC-TE) upon request ¿tting housing dimensions subMect to
changes accordingly”

3 Hours duration Emergency Unit “EMU” with battery pack Maintained “/M” or Non-Maintained “/NM” for one
Emergency Unit lamp, and for various lamp types and voltage networks combinations. “Additional Emergency Units to operate
more than one lamp on request”

110
Double Parabolic Specular Aluminium
Louver
SERIES : DPSM/DPSI/DPSC/DPSCM IP20
Technical Data
To Order : follow the sequence mr+gt+ht - ln / ls – cgt – vh – cgm - emu
Physical Characteristics

Frequency

Accessories

Emergency
Grid Type

Voltage
Reference

Lamp

Optional
Housing

Size
Number

Control
CM

Power
Factor
Model

Lamp

Gear
Type

Type

Unit
M I C
(concealed
(metric) (imperial) (concealed)
metric)
L W L W L W L W H
mm mm mm mm mm mm mm mm mm watt V / Hz

595 295 605 300 624 324 600 300 1


14
595 295 605 300 624 324 600 300 2 17

595 595 605 605 624 624 600 600 3 18 NS


24 Normal
Start FTB
595 595 605 605 624 624 600 600 4
None Fused
(standard Terminal
1195 295 1215 300 1226 324 1200 300 1 Block
plastic
28 DEOS
end-caps)
1195 295 1215 300 1226 324 1200 300 2 32 Electronic
3/NM
Starter HPF
1195 595 1215 605 1226 624 1200 600 3 36 3 hours
High TRW
54 Non-
G Power Temperature
1195 595 1215 605 1226 624 1200 600 4
220 - 240V Maintained
(for CRS Factor Resistant
DPS 110 end-bo[) Wire
1495 295 1515 300 1526 324 1500 300 1 EB
Electronic 50 / 60 Hz
35 3/M
1495 295 1515 300 1526 324 1500 300 2 High HF
49 3 hours
Frequency High TW
58 Maintained
1495 595 1515 605 1526 624 1500 600 3 Frequency Through
80 Wire

Applications Suitable to be used in: of¿ces, clinics, education premises, circulation area general indoor application. 1495 595 1515 605 1526 624 1500 600 4
EBD
Dimmable
595 295 605 300 624 324 600 300 1
Electronic
Made of press welded Cold Rolled Steel “CRS” sheet of tight construction to prevent light leakage, all metal parts 36L High
595 295 605 300 624 324 600 300 2 40L Frequency
Housing pre-treated with a full degreasing and phosphate process, painted in stove enameled white baked epo[y polyester mi[- CRS
powder to ensure high reÀectance of painted surfaces. Other color ¿nishes upon request. end-bo[ 55L
595 595 605 605 624 624 600 600 3
80L
Double parabolic specular anodized aluminum louvers, 595 595 605 605 624 624 600 600 4
Light Controller with cut-off angle less than 60o. Louvers are held to the body by means of special steel springs allowing easy
opening and diffuser suspension during maintenance.

Mounting Recessed lay-in or concealed. Suitable for ¿[ in Metric or Imperial or Concealed standard T-pro¿le false ceiling.
Photometrics & Dimensions
High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.
Control Gear High Frequency Electronic Control Gear “ECG”.
High Frequency Dimmable Electronic Control Gear “ECG”.
DPS 4/18W
220 - 240V , 50 / 60 Hz
Voltage / Frequency
“Other Voltages upon request”

1[22 mm ‘ hole on top.


Cable Entry
“E[tra knock-out holes upon request”
18, 36 58 watt T8/T26 Fluorescent for Normal Start “NS”, Electronic Start “DEOS” or Electronic High
Frequency “HF” Ballast “EB”.
17 32 watt T8 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
Lamps 14, 28 35 watt FH T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
24, 49, 54 80 watt F4 T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”. “Other lamps
(T5/T16 – T8/T26 – T12/T38 – TCL - TC-DE – TC-TE) upon request ¿tting housing dimensions subMect to
changes accordingly”

3 Hours duration Emergency Unit “EMU” with battery pack Maintained “/M” or Non-Maintained “/NM” for one
Emergency Unit lamp, and for various lamp types and voltage networks combinations. “Additional Emergency Units to operate
more than one lamp on request”

112
Deep Double Parabolic
Semi-Specular Aluminium Louvers
SERIES : DDPM/DDPI/DDPC/DDPCM IP20
Technical Data
To Order : follow the sequence mr+gt+ht - ln / ls – cgt – vh – cgm - emu
Physical Characteristics

Frequency

Accessories
Grid Type

Emergency
Voltage
Reference

Lamp

Optional
Housing

Size
Number

Control
CM

Power
Factor
Model

Lamp

Gear
Type

Type
M I C

Unit
(concealed
(metric) (imperial) (concealed)
metric)
L W L W L W L W H
mm mm mm mm mm mm mm mm mm watt V / Hz

595 295 605 300 624 324 600 300 1


14
595 295 605 300 624 324 600 300 2 17

595 595 605 605 624 624 600 600 3 18 NS


24 Normal
Start
595 595 605 605 624 624 600 600 4 FTB
None Fused
1195 295 1215 300 1226 324 1200 300 (standard 1 Terminal
plastic Block
28 DEOS
end-caps)
1195 295 1215 300 1226 324 1200 300 2 32 Electronic
HPF 3/NM
Starter
1195 595 1215 605 1226 624 1200 600 3 36 High 3 hours
54 Power TRW Non-
G 220 - 240V Factor Temperature Maintained
1195 595 1215 605 1226 624 1200 600 (for CRS 4
Resistant
DDP 145 end-bo[)
Wire
1495 295 1515 300 1526 324 1500 300 1 EB
35 Electronic 50 / 60 Hz
HF 3/M
1495 295 1515 300 1526 324 1500 300 2 High
49 Frequency High 3 hours
Frequency TW Maintained
1495 595 1515 605 1526 624 1500 600 3 58
Through
80 Wire
Applications Suitable to be used in: of¿ces, clinics, education premises, circulation area general indoor application. 1495 595 1515 605 1526 624 1500 600 4
EBD
Dimmable
595 295 605 300 624 324 600 300 1 Electronic
Made of press welded Cold Rolled Steel “CRS” sheet of tight construction to prevent light leakage, all metal parts 36L High
Housing pre-treated with a full degreasing and phosphate process, painted in stove enameled white baked epo[y polyester mi[- 595 295 605 300 624 324 600 300 2 40L Frequency
CRS
powder to ensure high reÀectance of painted surfaces. Other color ¿nishes upon request. end-bo[ 55L
595 595 605 605 624 624 600 600 3
80L
Deep double parabolic semi-specular anodized aluminum louvers, 595 595 605 605 624 624 600 600 4
Light Controller with cut-off angle less than 55o. Louvers are held to the body by means of special steel springs allowing easy
opening and diffuser suspension during maintenance.

Mounting Recessed lay-in or concealed. Suitable for ¿[ in Metric or Imperial or Concealed standard T-pro¿le false ceiling.
Photometrics & Dimensions
High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.
Control Gear High Frequency Electronic Control Gear “ECG”.
High Frequency Dimmable Electronic Control Gear “ECG”.
DDP 4/36W
220 - 240V , 50 / 60 Hz
Voltage / Frequency
“Other Voltages upon request”

1[22 mm ‘ hole on top.


Cable Entry
“E[tra knock-out holes upon request”
18, 36 58 watt T8/T26 Fluorescent for Normal Start “NS”, Electronic Start “DEOS” or Electronic High
Frequency “HF” Ballast “EB”.
17 32 watt T8 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
Lamps 14, 28 35 watt FH T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
24, 49, 54 80 watt F4 T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”. “Other lamps
(T5/T16 – T8/T26 – T12/T38 – TCL - TC-DE – TC-TE) upon request ¿tting housing dimensions subMect to
changes accordingly”

3 Hours duration Emergency Unit “EMU” with battery pack Maintained “/M” or Non-Maintained “/NM” for one
Emergency Unit lamp, and for various lamp types and voltage networks combinations. “Additional Emergency Units to operate
more than one lamp on request”

114
Spaced T5 Matt
SERIES : NRS5MM/NRS5MI/NRS5MC/NRS5MCM
IP20
Technical Data
To Order : follow the sequence mr+gt+ht - ln / ls – cgt – vh – cgm - emu
Physical Characteristics

Frequency

Accessories
Grid Type

Voltage

Emergency
Reference

Lamp

Optional
Size
Housing

Number

Control

Power
Factor
CM

Model

Lamp

Gear

/
Type

Type

Unit
M I C
(concealed
(metric) (imperial) (concealed)
metric)
L W L W L W L W H
mm mm mm mm mm mm mm mm mm watt V / Hz

- - - - - - - - -
FTB
Fused
595 295 605 300 - - - - 2
14 Terminal
24 Block
595 595 605 605 - - - - 3 3/NM
3 hours
Non-
595 595 605 605 - - - - 4 Maintained
TRW
EB Temperature
- - - - - - - - - Electronic Resistant
High Wire
1195 295 1215 300 - - - - 2 Frequency 220 - 240V
28 HF
CRS
NRS5M 55 High
end-bo[ 54 EBD
1195 595 1215 605 - - - - 3 Frequency
Dimmable 50 / 60 Hz
Electronic TW
1195 595 1215 605 - - - - 4 High Through
Frequency Wire
- - - - - - - - - 3/M
3 hours
Applications Suitable to be used in: of¿ces, clinics, education premises, circulation area general indoor application. 1495 295 1515 300 - - - - 2 35 Maintained
49
Made of press welded Cold Rolled Steel “CRS” sheet of tight construction to prevent light leakage, all metal parts 1495 595 1515 605 - - - - 3 80
pre-treated with a full degreasing and phosphate process, painted in stove enameled white baked epo[y polyester mi[-
Housing
powder to ensure high reÀectance of painted surfaces. 1495 595 1515 605 - - - - 4
Other color ¿nishes upon request.

Parabolic matt anodized aluminum spaced louvers, with cut-off angle less than 65o. Louvers are held to the
Light Controller
body by means of special steel springs allowing easy opening and diffuser suspension during maintenance.

Mounting Recessed lay-in or concealed. Suitable for ¿[ in Metric or Imperial or Concealed standard T-pro¿le false ceiling.
Photometrics & Dimensions
High Frequency Electronic Control Gear “ECG”.
Control Gear
High Frequency Dimmable Electronic Control Gear “ECG”.
NRS5M 2/28W
220 - 240V , 50 / 60 Hz
Voltage / Frequency
“Other Voltages upon request”

1[22 mm ‘ hole on top.


Cable Entry
“E[tra knock-out holes upon request”

14, 28 35 watt FH T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
Lamps
24, 49, 54 80 watt F4 T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”. H
W
3 Hours duration Emergency Unit “EMU” with battery pack Maintained “/M” or Non-Maintained “/NM” for one
Emergency Unit lamp, and for various lamp types and voltage networks combinations.
“Additional Emergency Units to operate more than one lamp on request”

116
White Plastic Louvers
SERIES : NLM/NLI
IP20
Technical Data
To Order : follow the sequence mr+gt+ht - ln / ls – cgt – vh – cgm – emu
Physical Characteristics

Frequency

Accessories

Emergency
Voltage
Grid Type

Reference

Lamp

Optional
Housing

Size
Number

Control

Power
Factor
Model

Lamp
UC

Gear
Type

Type

Unit
M I U
(Universal
(Metric) (Imperial) (Universal)
Compact)
L W L W L W L W H
mm mm mm mm mm mm mm mm mm watt v / Hz
595 293 605 300 620 315 1
14
595 293 605 300 620 315 2 17
595 595 605 605 620 620 3 18
None
(standard 24 NS
595 595 605 605 620 620 4
plastic Normal
FTB
1195 293 1215 300 1230 315 end-caps) 1 Start
28 Fused
1195 293 1215 300 1230 315 2 32 Terminal
Block
1195 595 1215 605 1230 620 3 36
DEOS
54 3/NM
1195 595 1215 605 1230 620 4 Electronic HPF
3 hours
- - 80 G Starter High
1495 293 1515 300 1530 315 1 TRW Non-
(for CRS 35 Power
Temperature Maintained
end-bo[) 220 - 240V Factor
1495 293 1515 300 1530 315 2 49 Resistant
NL Wire
1495 595 1515 605 1530 620 3 58 EB
Electronic 50 / 60 Hz
80
1495 595 1515 605 1530 620 4 High
3/M
Frequency HF
595 293 605 300 620 315 1 TW 3 hours
High
36L Through Maintained
Frequency
595 293 605 300 620 315 2 40L Wire

595 595 605 605 620 620 3 55L EBD


Applications Suitable to be used in: of¿ces, clinics, education premises, circulation area general indoor application. Dimmable
80L Electronic
595 595 605 605 620 620 CRS 4
Made of press welded Cold Rolled Steel “CRS” sheet of tight construction to prevent light leakage, all metal parts High
end-bo[
11L Frequency
pre-treated with a full degreasing and phosphate process, painted in stove enameled white baked epo[y polyester mi[- 1
Housing 18L/D/T
powder to ensure high reÀectance of painted surfaces. 26D/T
Other color ¿nishes upon request. - - - - - - 312 312 90
32T
2 42T
Flat half-inch styrene plastic white louvers, secured in an e[truded aluminum frame painted white. Frame 70T
Light Controller is held to the body by means of special steel springs allowing easy opening and diffuser suspension during
maintenance.
Recessed lay-in or universal. Suitable for ¿[ in Metric or Imperial or Universal Concealed standard T-pro¿le
Mounting
false ceiling.
Photometrics & Dimensions
High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.
Control Gear High Frequency Electronic Control Gear “ECG”.
High Frequency Dimmable Electronic Control Gear “ECG”.
NL 2/36W
220 - 240V , 50 / 60 Hz
Voltage / Frequency
“Other Voltages upon request”

1[22 mm ‘ hole on top.


Cable Entry
“E[tra knock-out holes upon request”
18, 36 58 watt T8/T26 Fluorescent for Normal Start “NS”, Electronic Start “DEOS” or Electronic High
Frequency “HF” Ballast “EB”.
17 32 watt T8 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
Lamps 14, 28 35 watt FH T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
24, 49, 54 80 watt F4 T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”. “Other lamps
(T5/T16 – T8/T26 – T12/T38 – TCL – TC-D – TC-DE – TC-TE) upon request ¿tting housing dimensions
subMect to changes accordingly”

3 Hours duration Emergency Unit “EMU” with battery pack Maintained “/M” or Non-Maintained “/NM” for one
Emergency Unit lamp, and for various lamp types and voltage networks combinations.
“Additional Emergency Units to operate more than one lamp on request”

118
Silver Plastic Louvers
SERIES : NLSM/NLSI
IP20
Technical Data
To Order : follow the sequence mr+gt+ht - ln / ls – cgt – vh – cgm – emu
Physical Characteristics

Frequency

Accessories
Grid Type

Emergency
Voltage
Reference

Lamp

Optional
Housing

Size
Number

Control
UC

Power
Factor
Model

Lamp

Gear
Type

Type
M I U

Unit
(Universal
(Metric) (Imperial) (Universal)
Compact)
L W L W L W L W H
mm mm mm mm mm mm mm mm mm watt v / Hz
595 293 605 300 620 315 1
14
595 293 605 300 620 315 2 17
595 595 605 605 620 620 3 18
None
24 NS
595 595 605 605 620 620 (standard 4 Normal
plastic
Start FTB
1195 293 1215 300 1230 315 end-caps) 1 28 Fused
1195 293 1215 300 1230 315 2 32 Terminal
Block
1195 595 1215 605 1230 620 3 36 DEOS
54 Electronic HPF 3/NM
1195 595 1215 605 1230 620 4 Starter High 3 hours
- - 80 G
1495 293 1515 300 1530 315 1 Power TRW Non-
(for CRS 35 Factor Temperature Maintained
end-bo[) 220 - 240V
1495 293 1515 300 1530 315 2 49 Resistant
NLS Wire
1495 595 1515 605 1530 620 3 58 EB
80 Electronic 50 / 60 Hz
1495 595 1515 605 1530 620 4 High HF 3/M
595 293 605 300 620 315 1 Frequency High TW 3 hours
36L Frequency Through Maintained
595 293 605 300 620 315 2 40L Wire

Applications Suitable to be used in: of¿ces, clinics, education premises, circulation area general indoor application. 595 595 605 605 620 620 3 55L EBD
80L Dimmable
595 595 605 605 620 620 CRS 4 Electronic
Made of press welded Cold Rolled Steel “CRS” sheet of tight construction to prevent light leakage, all metal parts end-bo[ High
pre-treated with a full degreasing and phosphate process, painted in stove enameled white baked epo[y polyester mi[- 11L
Housing 1 Frequency
powder to ensure high reÀectance of painted surfaces. 18L/D/T
Other color ¿nishes upon request. 26D/T
- - - - - - 312 312 90
32T
Flat half-inch styrene plastic silver louvers, secured in an e[truded aluminum frame painted white. Frame 2 42T
70T
Light Controller is held to the body by means of special steel springs allowing easy opening and diffuser suspension during
maintenance.
Recessed lay-in or universal. Suitable for ¿[ in Metric or Imperial or Universal Concealed standard T-pro¿le
Mounting
false ceiling.
Photometrics & Dimensions
High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.
Control Gear High Frequency Electronic Control Gear “ECG”.
High Frequency Dimmable Electronic Control Gear “ECG”.
NLS 2/36W
220 - 240V , 50 / 60 Hz
Voltage / Frequency
“Other Voltages upon request”

1[22 mm ‘ hole on top.


Cable Entry
“E[tra knock-out holes upon request”
18, 36 58 watt T8/T26 Fluorescent for Normal Start “NS”, Electronic Start “DEOS” or Electronic High
Frequency “HF” Ballast “EB”.
17 32 watt T8 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
Lamps 14, 28 35 watt FH T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
24, 49, 54 80 watt F4 T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”. “Other lamps
(T5/T16 – T8/T26 – T12/T38 – TCL – TC-D – TC-DE – TC-TE) upon request ¿tting housing dimensions
subMect to changes accordingly”

3 Hours duration Emergency Unit “EMU” with battery pack Maintained “/M” or Non-Maintained “/NM” for one
Emergency Unit lamp, and for various lamp types and voltage networks combinations.
“Additional Emergency Units to operate more than one lamp on request”

120
Golden Plastic Louvers
SERIES : NLGM/NLGI
IP20
Technical Data
To Order : follow the sequence mr+gt+ht - ln / ls – cgt – vh – cgm – emu
Physical Characteristics

Frequency

Accessories
Grid Type

Emergency
Voltage
Reference

Lamp

Optional
Housing

Size
Number

Control
UC

Power
Factor
Model

Lamp

Gear
Type

Type

/
M I U

Unit
(Universal
(Metric) (Imperial) (Universal)
Compact)
L W L W L W L W H
mm mm mm mm mm mm mm mm mm watt v / Hz
595 293 605 300 620 315 1
14
595 293 605 300 620 315 2 17
595 595 605 605 620 620 3 18
None
24 NS
595 595 605 605 620 620 (standard 4 Normal
plastic
Start FTB
1195 293 1215 300 1230 315 end-caps) 1 28 Fused
1195 293 1215 300 1230 315 2 32 Terminal
Block
1195 595 1215 605 1230 620 3 36 DEOS
54 Electronic HPF 3/NM
1195 595 1215 605 1230 620 4 Starter High 3 hours
- - 80 G
1495 293 1515 300 1530 315 1 Power TRW Non-
(for CRS 35 Factor Temperature Maintained
1495 293 1515 300 1530 315
end-bo[)
2
220 - 240V
49 Resistant
NLG Wire
1495 595 1515 605 1530 620 3 58
EB
80 Electronic 50 / 60 Hz
1495 595 1515 605 1530 620 4
High HF 3/M
595 293 605 300 620 315 1 Frequency High TW 3 hours
36L Frequency Through Maintained
595 293 605 300 620 315 2 40L Wire
Applications Suitable to be used in: of¿ces, clinics, education premises, circulation area general indoor application.
595 595 605 605 620 620 3 55L EBD
80L Dimmable
Made of press welded Cold Rolled Steel “CRS” sheet of tight construction to prevent light leakage, all metal parts 595 595 605 605 620 620 CRS 4 Electronic
pre-treated with a full degreasing and phosphate process, painted in stove enameled white baked epo[y polyester mi[- end-bo[ High
Housing 11L
powder to ensure high reÀectance of painted surfaces. 1 18L/D/T
Frequency
Other color ¿nishes upon request. 26D/T
- - - - - - 312 312 90
32T
Flat half-inch styrene plastic golden louvers, secured in an e[truded aluminum frame painted white. Frame 2 42T
Light Controller is held to the body by means of special steel springs allowing easy opening and diffuser suspension during 70T
maintenance.
Recessed lay-in or universal. Suitable for ¿[ in Metric or Imperial or Universal Concealed standard T-pro¿le
Mounting
false ceiling.
Photometrics & Dimensions
High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.
Control Gear High Frequency Electronic Control Gear “ECG”.
High Frequency Dimmable Electronic Control Gear “ECG”.
NLG 2/36W
220 - 240V , 50 / 60 Hz
Voltage / Frequency
“Other Voltages upon request”

1[22 mm ‘ hole on top.


Cable Entry
“E[tra knock-out holes upon request”
18, 36 58 watt T8/T26 Fluorescent for Normal Start “NS”, Electronic Start “DEOS” or Electronic High
Frequency “HF” Ballast “EB”.
17 32 watt T8 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
Lamps 14, 28 35 watt FH T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
24, 49, 54 80 watt F4 T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”. “Other lamps
(T5/T16 – T8/T26 – T12/T38 – TCL – TC-D – TC-DE – TC-TE) upon request ¿tting housing dimensions
subMect to changes accordingly”

3 Hours duration Emergency Unit “EMU” with battery pack Maintained “/M” or Non-Maintained “/NM” for one
Emergency Unit lamp, and for various lamp types and voltage networks combinations.
“Additional Emergency Units to operate more than one lamp on request”

122
White Plastic Louvers
SERIES : TLM/TLI/TLC/TLCM
IP20
Technical Data
To Order : follow the sequence mr+gt+ht - ln / ls – cgt – vh – cgm - emu
Physical Characteristics

Frequency

Accessories
Grid Type

Emergency
Voltage
Reference

Lamp

Optional
Housing

Size
Number

Control
CM

Power
Factor
Model

Lamp

Gear
Type

Type

/
M I C

Unit
(concealed
(metric) (imperial) (concealed)
metric)
L W L W L W L W H
mm mm mm mm mm mm mm mm mm watt V / Hz

595 295 605 300 624 324 600 300 1


14
595 295 605 300 624 324 600 300 2 17

595 595 605 605 624 624 600 600 3 18 NS


24 Normal
Start FTB
595 595 605 605 624 624 600 600 4
None Fused
(standard Terminal
1195 295 1215 300 1226 324 1200 300 1 Block
plastic
28 DEOS
end-caps)
1195 295 1215 300 1226 324 1200 300 2 32 Electronic
3/NM
Starter
1195 595 1215 605 1226 624 1200 600 3 36 HPF 3 hours
TRW
54 High Non-
G Temperature
1195 595 1215 605 1226 624 1200 600 4
220 - 240V Power Maintained
(for CRS Resistant
Factor
TL 100 end-bo[) Wire
1495 295 1515 300 1526 324 1500 300 1 EB
Electronic 50 / 60 Hz
35 3/M
1495 295 1515 300 1526 324 1500 300 2 High
49 HF 3 hours
Frequency TW
High Maintained
1495 595 1515 605 1526 624 1500 600 3 58 Through
Frequency
80 Wire
1495 595 1515 605 1526 624 1500 600 4
Applications Suitable to be used in: of¿ces, clinics, education premises, circulation area general indoor application. EBD
Dimmable
595 295 605 300 624 324 600 300 1 Electronic
Made of press welded Cold Rolled Steel “CRS” sheet of tight construction to prevent light leakage, all metal parts 36L High
pre-treated with a full degreasing and phosphate process, painted in stove enameled white baked epo[y polyester mi[- 595 295 605 300 624 324 600 300 2 40L Frequency
Housing CRS
powder to ensure high reÀectance of painted surfaces. end-bo[ 55L
595 595 605 605 624 624 600 600 3
Other color ¿nishes upon request. 80L
Flat half-inch styrene plastic white louvers, secured in an e[truded aluminum frame painted white. Frame is 595 595 605 605 624 624 600 600 4
Light Controller held to the body by means of special hinges and latches allow easy opening and diffuser suspension during
maintenance.

Mounting Recessed lay-in or concealed. Suitable for ¿[ in Metric or Imperial or Concealed standard T-pro¿le false ceiling.
Photometrics & Dimensions
High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.
Control Gear High Frequency Electronic Control Gear “ECG”.
High Frequency Dimmable Electronic Control Gear “ECG”.
TL 2/36W
220 - 240V , 50 / 60 Hz
Voltage / Frequency
“Other Voltages upon request”

1[22 mm ‘ hole on top.


Cable Entry
“E[tra knock-out holes upon request”
18, 36 58 watt T8/T26 Fluorescent for Normal Start “NS”, Electronic Start “DEOS” or Electronic High
Frequency “HF” Ballast “EB”.
17 32 watt T8 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
Lamps 14, 28 35 watt FH T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
24, 49, 54 80 watt F4 T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”. “Other lamps
(T5/T16 – T8/T26 – T12/T38 – TCL – TC-D – TC-DE – TC-TE) upon request ¿tting housing dimensions
subMect to changes accordingly”

3 Hours duration Emergency Unit “EMU” with battery pack Maintained “/M” or Non-Maintained “/NM” for one
Emergency Unit lamp, and for various lamp types and voltage networks combinations.
“Additional Emergency Units to operate more than one lamp on request”

124
Silver Plastic Louvers
SERIES : TLSM/TLSI/TLSC/TLSCM
IP20
Technical Data
To Order : follow the sequence mr+gt+ht - ln / ls – cgt – vh – cgm - emu
Physical Characteristics

Frequency

Accessories

Emergency
Grid Type

Voltage
Reference

Lamp

Optional
Housing

Size
Number

Control

Power
Factor
Model

Lamp
CM

Gear
Type

Type

Unit
M I C
(concealed
(metric) (imperial) (concealed)
metric)
L W L W L W L W H
mm mm mm mm mm mm mm mm mm watt V / Hz

595 295 605 300 624 324 600 300 1


14
595 295 605 300 624 324 600 300 2 17

595 595 605 605 624 624 600 600 3 18


NS
24 Normal
FTB
595 595 605 605 624 624 600 600 4 Start
None Fused
(standard Terminal
1195 295 1215 300 1226 324 1200 300 1 Block
plastic
28
end-caps) DEOS
1195 295 1215 300 1226 324 1200 300 2 32 Electronic 3/NM
HPF
1195 595 1215 605 1226 624 1200 600 3 36 Starter 3 hours
High TRW
54 Non-
G Power Temperature
1195 595 1215 605 1226 624 1200 600 4
220 - 240V Maintained
(for CRS Factor Resistant
TLS 100 end-bo[) Wire
EB
1495 295 1515 300 1526 324 1500 300 1
Electronic 50 / 60 Hz
35 High 3/M
1495 295 1515 300 1526 324 1500 300 2 HF
49 Frequency 3 hours
High TW
Maintained
1495 595 1515 605 1526 624 1500 600 3 58 Frequency Through
80 Wire
Applications Suitable to be used in: of¿ces, clinics, education premises, circulation area general indoor application. 1495 595 1515 605 1526 624 1500 600 4 EBD
Dimmable
595 295 605 300 624 324 600 300 1 Electronic
Made of press welded Cold Rolled Steel “CRS” sheet of tight construction to prevent light leakage, all metal parts 36L High
pre-treated with a full degreasing and phosphate process, painted in stove enameled white baked epo[y polyester mi[- 595 295 605 300 624 324 600 300 2 Frequency
Housing CRS 40L
powder to ensure high reÀectance of painted surfaces.
Other color ¿nishes upon request. end-bo[ 55L
595 595 605 605 624 624 600 600 3
80L
Flat half-inch styrene plastic silver louvers, secured in an e[truded aluminum frame painted white. Frame is 595 595 605 605 624 624 600 600 4
Light Controller held to the body by means of special hinges and latches allow easy opening and diffuser suspension during
maintenance.

Mounting Recessed lay-in or concealed. Suitable for ¿[ in Metric or Imperial or Concealed standard T-pro¿le false ceiling.
Photometrics & Dimensions
High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.
Control Gear High Frequency Electronic Control Gear “ECG”.
High Frequency Dimmable Electronic Control Gear “ECG”.
TLS 2/36W
220 - 240V , 50 / 60 Hz
Voltage / Frequency
“Other Voltages upon request”

1[22 mm ‘ hole on top.


Cable Entry
“E[tra knock-out holes upon request”
18, 36 58 watt T8/T26 Fluorescent for Normal Start “NS”, Electronic Start “DEOS” or Electronic High
Frequency “HF” Ballast “EB”.
17 32 watt T8 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
Lamps 14, 28 35 watt FH T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
24, 49, 54 80 watt F4 T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”. “Other lamps
(T5/T16 – T8/T26 – T12/T38 – TCL – TC-D – TC-DE – TC-TE) upon request ¿tting housing dimensions
subMect to changes accordingly”

3 Hours duration Emergency Unit “EMU” with battery pack Maintained “/M” or Non-Maintained “/NM” for one
Emergency Unit lamp, and for various lamp types and voltage networks combinations.
“Additional Emergency Units to operate more than one lamp on request”

126
Golden Plastic Louvers
SERIES : TLGM/TLGI/TLGC/TLGCM IP20
Technical Data
To Order : follow the sequence mr+gt+ht - ln / ls – cgt – vh – cgm - emu
Physical Characteristics

Frequency

Accessories
Grid Type

Emergency
Voltage
Reference

Lamp

Optional
Housing

Size
Number

Control

Power
Factor
CM

Model

Lamp

Gear
Type

Type

Unit
M I C
(concealed
(metric) (imperial) (concealed)
metric)
L W L W L W L W H
mm mm mm mm mm mm mm mm mm watt V / Hz

595 295 605 300 624 324 600 300 1


14
595 295 605 300 624 324 600 300 2 17

595 595 605 605 624 624 600 600 3 18


NS
24 Normal
FTB
595 595 605 605 624 624 600 600 4 Start
None Fused
(standard Terminal
1195 295 1215 300 1226 324 1200 300 1 Block
plastic
28
end-caps) DEOS
1195 295 1215 300 1226 324 1200 300 2 32 Electronic 3/NM
HPF
1195 595 1215 605 1226 624 1200 600 3 36 Starter 3 hours
High TRW
54 Non-
G Power Temperature
1195 595 1215 605 1226 624 1200 600 4
220 - 240V Maintained
(for CRS Factor Resistant
TLG 100 end-bo[) Wire
EB
1495 295 1515 300 1526 324 1500 300 1 Electronic 50 / 60 Hz
35 High 3/M
1495 295 1515 300 1526 324 1500 300 2 HF
49 Frequency 3 hours
High TW
58 Maintained
1495 595 1515 605 1526 624 1500 600 3 Frequency Through
80 Wire
1495 595 1515 605 1526 624 1500 600 4 EBD
Applications Suitable to be used in: of¿ces, clinics, education premises, circulation area general indoor application.
Dimmable
595 295 605 300 624 324 600 300 1 Electronic
Made of press welded Cold Rolled Steel “CRS” sheet of tight construction to prevent light leakage, all metal parts 36L High
pre-treated with a full degreasing and phosphate process, painted in stove enameled white baked epo[y polyester mi[- 595 295 605 300 624 324 600 300 2 Frequency
Housing CRS 40L
powder to ensure high reÀectance of painted surfaces. end-bo[
595 595 605 605 624 624 600 600 3 55L
Other color ¿nishes upon request.
80L
Flat half-inch styrene plastic silver louvers, secured in an e[truded aluminum frame painted white. Frame is 595 595 605 605 624 624 600 600 4
Light Controller held to the body by means of special hinges and latches allow easy opening and diffuser suspension during
maintenance.

Mounting Recessed lay-in or concealed. Suitable for ¿[ in Metric or Imperial or Concealed standard T-pro¿le false ceiling.
Photometrics & Dimensions
High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.
Control Gear High Frequency Electronic Control Gear “ECG”.
High Frequency Dimmable Electronic Control Gear “ECG”.
TLG 2/36W
220 - 240V , 50 / 60 Hz
Voltage / Frequency
“Other Voltages upon request”

1[22 mm ‘ hole on top.


Cable Entry
“E[tra knock-out holes upon request”
18, 36 58 watt T8/T26 Fluorescent for Normal Start “NS”, Electronic Start “DEOS” or Electronic High
Frequency “HF” Ballast “EB”.
17 32 watt T8 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
Lamps 14, 28 35 watt FH T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
24, 49, 54 80 watt F4 T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”. “Other lamps
(T5/T16 – T8/T26 – T12/T38 – TCL – TC-D – TC-DE – TC-TE) upon request ¿tting housing dimensions
subMect to changes accordingly”

3 Hours duration Emergency Unit “EMU” with battery pack Maintained “/M” or Non-Maintained “/NM” for one
Emergency Unit lamp, and for various lamp types and voltage networks combinations.
“Additional Emergency Units to operate more than one lamp on request”

128
Metalized Plastic Louvers
SERIES : NRM/NRI/NRC/NRCM
IP20
Technical Data

To Order : follow the sequence mr+gt+ht - ln / ls – cgt – vh – cgm - emu


Physical Characteristics

Frequency

Accessories
Grid Type

Emergency
Voltage
Reference

Lamp

Optional
Housing

Size
Number

Control
CM

Power
Factor
Model

Lamp

Gear
Type

Type

Unit
M I C
(concealed
(metric) (imperial) (concealed)
metric)
L W L W L W L W H
mm mm mm mm mm mm mm mm mm watt V / Hz

FTB
600 595 605 605 624 624 600 600 14 Fused
Terminal
Block
EB
Electronic
High 3/NM
Frequency 3 hours
TRW
Non-
Temperature
None 220 - 240V Maintained
Resistant
(standard HF
NR 600 595 605 605 624 624 600 600 95 4 18 Wire
plastic High
end-caps) 50 / 60 Hz Frequency
3/M
EBD 3 hours
TW
Dimmable Maintained
Through
Electronic
Wire
High
Frequency
Applications Suitable to be used in: of¿ces, clinics, education premises, circulation area general indoor application.
600 595 605 605 624 624 600 600 24

Made of press welded Cold Rolled Steel “CRS” sheet of tight construction to prevent light leakage, all metal parts
pre-treated with a full degreasing and phosphate process, painted in stove enameled white baked epo[y polyester mi[-
Housing
powder to ensure high reÀectance of painted surfaces.
Other color ¿nishes upon request.
Parabolic shaped specular anodized aluminum louvers and transversal vanes with translucent ribbed prisms polycar-
bonate sheet.
Louvers are held to the body by means of special steel springs.
Light Controller
“The patented optic gives precise light control, discomfort reÀectance¶s
And glare are avoided by use of transversal vanes with precise prisms,
And the use of batwing mirrors avoids glare on the horizontal plane.”
Photometrics & Dimensions
Mounting Recessed lay-in or concealed. Suitable for ¿[ in Metric or Imperial or Concealed standard T-pro¿le false ceiling.

High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.


Control Gear High Frequency Electronic Control Gear “ECG”. NRI 4/18W
High Frequency Dimmable Electronic Control Gear “ECG”.

220 - 240V , 50 / 60 Hz
Voltage / Frequency
“Other Voltages upon request”

1[22 mm ‘ hole on top.


Cable Entry
“E[tra knock-out holes upon request”
18, 36 58 watt T8/T26 Fluorescent for Normal Start “NS”, Electronic Start “DEOS” or Electronic High
Frequency “HF” Ballast “EB”.
17 32 watt T8 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
Lamps
14, 28 35 watt FH T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
24, 49, 54 80 watt F4 T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.“Other lamps (T5/
T16 – T8/T26 – T12/T38 – TCL ) upon request ¿tting housing dimensions subMect to changes accordingly”

3 Hours duration Emergency Unit “EMU” with battery pack Maintained “/M” or Non-Maintained “/NM” for one
Emergency Unit lamp, and for various lamp types and voltage networks combinations. “Additional Emergency Units to operate
more than one lamp on request”

130
Mellow
SERIES : RCE
IP20
Technical Data
To Order : follow the sequence mr+gt+ht - ln / ls – cgt – vh – cgm - emu
Physical Characteristics

Frequency
Grid Type

Accessories
Voltage/

Emergency
Reference

Lamp

Optional
Size
Housing

Number

Control

Power
Factor
Model
CM

Lamp

Gear
Type

Type

Unit
M I C
(concealed
(metric) (imperial) (concealed)
metric)
L W L W L W L W H
mm mm mm mm mm mm mm mm mm watt V / Hz

- - - - - - - - 1
FTB
Fused
- - - - - - - - 2
Terminal
36L Block
- - - - - - - - - 3/NM
3 hours
NS Non-
- - - - - - - - - Normal Maintained
Start TRW
Temperature
- - - - - - - - 1
EB Resistant
Electronic 220 - 240V HPF Wire
598 598 - - - - - - 2
CRS High High
RCE 167 40L
end-bo[ Frequency Power
- - - - - - - - - Factor
50 / 60 Hz
EBD TW
- - - - - - - - - Dimmable Through
Electronic Wire
- - - - - - - - 1 High 3/M
Frequency 3 hours
Applications Suitable to be used in: of¿ces, clinics, education premises, circulation area general indoor application. - - - - - - - - 2 HF Maintained
55L High
- - - - - - - - - Frequency
Made of press welded Cold Rolled Steel “CRS” sheet of tight construction to prevent light leakage, all metal parts
pre-treated with a full degreasing and phosphate process, painted in stove enameled white baked epo[y polyester mi[-
Housing - - - - - - - - -
powder to ensure high reÀectance of painted surfaces.
Other color ¿nishes upon request.
Involute reÀector comprises two sheet steel elements accurately pro¿led to a precision curve, ¿nish with a special white
Light Controller paint to obscure the reÀected lamp images and ensure a slow rate of change of luminance on the reÀector surface.
The die-cast end pieces rigidly hold the perforated white steel refractor and opal backing diffuser in place.

Mounting Concealed. Suitable for ¿[ in Metric or Imperial or Concealed standard T-pro¿le false ceiling.
Photometrics & Dimensions
High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.
Control Gear High Frequency Electronic Control Gear “ECG”.
High Frequency Dimmable Electronic Control Gear “ECG”.
RCE 2/55W
220 - 240V , 50 / 60 Hz
Voltage / Frequency
“Other Voltages upon request”

1[22 mm ‘ hole on top.


Cable Entry
“E[tra knock-out holes upon request”

36, 40 55 watt TC-L Compact Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
Lamps
H1

3 Hours duration Emergency Unit “EMU” with battery pack Maintained “/M” or Non-Maintained “/NM” for one
Emergency Unit lamp, and for various lamp types and voltage networks combinations.
“Additional Emergency Units to operate more than one lamp on request” W

L
132
Twin Mellow
SERIES : RTM/RTI/RTC/RTCM
IP20
Technical Data

To Order : follow the sequence mr+gt+ht - ln / ls – cgt – vh – cgm - emu


Physical Characteristics

Frequency

Accessories
Voltage
Grid Type

Emergency
Reference

Lamp
Size

Optional
Housing

Number

Control

Power
Factor
Model
CM

Lamp

/
Gear
Type

Type

Unit
M I C
(concealed
(metric) (imperial) (concealed)
metric)
L W L W L W L W H
mm mm mm mm mm mm mm mm mm watt V / Hz

- - - - - - - - -
FTB
Fused
- - - - - - - - 2
Terminal
36L Block
- - - - - - - - - 3/NM
3 hours
Non-
- - - - - - - - - NS Maintained
Normal TRW
Start Temperature
- - - - - - - - -
Resistant
EB Wire
595 595 605 605 624 624 600 600 2 Electronic 220 - 240V HPF
CRS High High
RT 100 40L
end-bo[ Frequency Power
- - - - - - - - - 50 / 60 Hz Factor
EBD TW
- - - - - - - - - Dimmable Through
Electronic Wire
High
Applications Suitable to be used in: of¿ces, clinics, education premises, circulation area general indoor application. - - - - - - - - - Frequency 3/M
3 hours
Made of press welded Cold Rolled Steel “CRS” sheet of tight construction to prevent light leakage, all metal parts - - - - - - - - 2 Maintained
HF
pre-treated with a full degreasing and phosphate process, painted in stove enameled white baked epo[y polyester mi[- 55L High
Housing
powder to ensure high reÀectance of painted surfaces. Frequency
- - - - - - - - -
Other color ¿nishes upon request.
Vault reÀector made of quality sheet steel accurately pro¿led to a precision curve, ¿nish with a special white paint to obscure - - - - - - - - -
Light Controller the reÀected lamp images and ensure a slow rate of change of luminance on the reÀector surface. Two sideward perfo-
rated or plain white steel reÀectors with or without opal backing diffuser in place.

Mounting Recessed lay-in or concealed. Suitable for ¿[ in Metric or Imperial or Concealed standard T-pro¿le false ceiling.
Photometrics & Dimensions
High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.
Control Gear High Frequency Electronic Control Gear “ECG”.
High Frequency Dimmable Electronic Control Gear “ECG”.
RT 2/36W
220 - 240V , 50 / 60 Hz
Voltage / Frequency
“Other Voltages upon request”

1[22 mm ‘ hole on top.


Cable Entry
“E[tra knock-out holes upon request”

36, 40 55 watt TC-L Compact Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
Lamps

H
3 Hours duration Emergency Unit “EMU” with battery pack Maintained “/M” or Non-Maintained “/NM” for one W
Emergency Unit lamp, and for various lamp types and voltage networks combinations.
“Additional Emergency Units to operate more than one lamp on request”

134
Hygienic Opal
SERIES : TOHM/TOHI/TOHC/TOHCM
IP65
Technical Data
To Order : follow the sequence mr+gt+ht - ln / ls – cgt – vh – cgm - emu
Physical Characteristics

Frequency

Accessories
Grid Type

Emergency
Voltage
Reference

Lamp

Optional
Housing

Size
Number
CM

Control

Power
Factor
Model

Lamp

Gear
M I C

Type

Type

Unit
(concealed
(metric) (imperial) (concealed)
metric)
L W L W L W L W H
mm mm mm mm mm mm mm mm mm watt V / Hz

595 295 605 300 624 324 600 300 1


14
595 295 605 300 624 324 600 300 2 17
NS
595 595 605 605 624 624 600 600 3 18
Normal
24 Start
FTB
595 595 605 605 624 624 600 600 4
None Fused
(standard Terminal
1195 295 1215 300 1226 324 1200 300 1 Block
plastic DEOS
28
end-caps) Electronic
1195 295 1215 300 1226 324 1200 300 2 32 Starter 3/NM
HPF
1195 595 1215 605 1226 624 1200 600 3 36 3 hours
High TRW
54 Non-
G Power Temperature
1195 595 1215 605 1226 624 1200 600 4
220 - 240V Maintained
(for CRS Factor Resistant
TOH 100 end-bo[) Wire
1495 295 1515 300 1526 324 1500 300 1 EB 50 / 60 Hz
35 Electronic 3/M
1495 295 1515 300 1526 324 1500 300 2 HF
49 High 3 hours
High TW
Frequency Maintained
1495 595 1515 605 1526 624 1500 600 3 58 Frequency Through
80 Wire
Suitable to be used in: Hygienic areas with low dust particles and germ counts, e.g. hospital, operating theaters, pharmacies, 1495 595 1515 605 1526 624 1500 600 4
Applications
laboratories, pharmaceutical, food processing, patients rooms, etc… EBD
595 295 605 300 624 324 600 300 1 Dimmable
Made of press welded Cold Rolled Steel “CRS” sheet of tight construction to prevent light leakage, diffuser frame 36L Electronic
made of Plain Aluminum, all metal parts pre-treated with a full degreasing and phosphate process painted in stove 595 295 605 300 624 324 600 300 2 High
Housing CRS 40L
Frequency
enameled white baked epo[y polyester mi[-powder to ensure high reÀectance of painted surfaces.
end-bo[ 55L
“Other color ¿nishes upon request” 595 595 605 605 624 624 600 600 3
80L
Standard opal Àat diffuser secured in an e[truded aluminum frame ¿nished in satin white. Louvers ¿[ed on white 595 595 605 605 624 624 600 600 4
aluminum frame incorporates tempered glass or polycarbonate hygienic layer, special UV resistant gasket seal
ensures tight ¿t between body and diffuser, suspension kit supplied for easy maintenance, also for easy installation,
Light Controller
a suspension system consisting of a special kit adMustable from inside the luminaire can be supplied on request.
Hygienic layer features UV resistant, High resistant for mechanical impact and high resistant for most of the
disinfectant chemicals used in operation theatre rooms, delivery rooms, etc…
Photometrics & Dimensions
Mounting Concealed. Suitable for ¿[ in Metric or Imperial or Concealed standard T-pro¿le false ceiling.

High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.


Control Gear High Frequency Electronic Control Gear “ECG”. TOH 2/36W
High Frequency Dimmable Electronic Control Gear “ECG”.

220 - 240V , 50 / 60 Hz
Voltage / Frequency
. “Other Voltages upon request”

Cable Entry 1[22 mm ‘ hole on top. “E[tra knock-out holes upon request”

18, 36 58 watt T8/T26 Fluorescent for Normal Start “NS”, Electronic Start “DEOS” or Electronic High Frequency
17 32 watt T8 Fluorescent for Electronic High Frequency “HF” Ballast “EB”. 14, 28 35 watt FH T5/T16 Fluorescent
Lamps for Electronic High Frequency “HF” Ballast “EB”. 24, 49, 54 80 watt F4 T5/T16 Fluorescent for Electronic High
Frequency “HF” Ballast “EB”. “Other lamps (T5/T16 – T8/T26 – T12/T38 – TCL - TC-DE – TC-TE upon request
¿tting housing dimensions subMect to changes accordingly”

3 Hours duration Emergency Unit “EMU” with battery pack Maintained “/M” or Non-Maintained “/NM” for one lamp,
Emergency Unit and for various lamp types and voltage networks combinations.
“Additional Emergency Units to operate more than one lamp on request”

136
IP65
Hygienic Prismatic
SERIES : TPHM/TPHI/TPHC/TPHCM

Technical Data
To Order : follow the sequence mr+gt+ht - ln / ls – cgt – vh – cgm - emu
Physical Characteristics

Frequency

Accessories
Grid Type

Emergency
Voltage
Reference

Lamp

Optional
Housing

Size
Number

Control

Power
Factor
CM

Model

Lamp

Gear
Type

Type

Unit
M I C
(concealed
(metric) (imperial) (concealed)
metric)
L W L W L W L W H
mm mm mm mm mm mm mm mm mm watt V / Hz

595 295 605 300 624 324 600 300 1


14
595 295 605 300 624 324 600 300 2 17

595 595 605 605 624 624 600 600 3 18 NS


24 Normal
Start FTB
595 595 605 605 624 624 600 600 4
None Fused
(standard Terminal
1195 295 1215 300 1226 324 1200 300 1 Block
plastic
28 DEOS
end-caps)
1195 295 1215 300 1226 324 1200 300 2 32 Electronic
3/NM
Starter
1195 595 1215 605 1226 624 1200 600 3 36 HPF 3 hours
TRW
54 High Non-
G Temperature
1195 595 1215 605 1226 624 1200 600 4
220 - 240V Power Maintained
(for CRS Resistant
Factor
TPH 100 end-bo[) Wire
1495 295 1515 300 1526 324 1500 300 1 EB
Electronic 50 / 60 Hz
35 3/M
1495 295 1515 300 1526 324 1500 300 2 High
49 HF 3 hours
Frequency TW
High Maintained
1495 595 1515 605 1526 624 1500 600 3 58 Through
Frequency
Suitable to be used in: Hygienic areas with low dust particles and germ counts, e.g. hospital, operating theaters, pharmacies, 80 Wire
Applications 1495 595 1515 605 1526 624 1500 600 4
laboratories, pharmaceutical, food processing, patients rooms, etc…
EBD
Dimmable
Made of press welded Cold Rolled Steel “CRS” sheet of tight construction to prevent light leakage, diffuser frame 595 295 605 300 624 324 600 300 1 Electronic
made of Plain Aluminum, all metal parts pre-treated with a full degreasing and phosphate process painted in stove 36L High
Housing 595 295 605 300 624 324 600 300 2
enameled white baked epo[y polyester mi[-powder to ensure high reÀectance of painted surfaces. CRS 40L Frequency
“Other color ¿nishes upon request” end-bo[ 55L
595 595 605 605 624 624 600 600 3
Standard prismatic Àat diffuser secured in an e[truded aluminum frame ¿nished in satin white. Louvers ¿[ed on 80L
white aluminum frame incorporates tempered glass or polycarbonate hygienic layer, special UV resistant gasket 595 595 605 605 624 624 600 600 4
seal ensures tight ¿t between body and diffuser, suspension kit supplied for easy maintenance, also for easy
Light Controller
installation, a suspension system consisting of a special kit adMustable from inside the luminaire can be supplied on
request. Hygienic layer features UV resistant, High resistant for mechanical impact and high resistant for most of the
disinfectant chemicals used in operation theatre rooms, delivery rooms, etc…
Photometrics & Dimensions
Mounting Concealed. Suitable for ¿[ in Metric or Imperial or Concealed standard T-pro¿le false ceiling.

High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.


Control Gear High Frequency Electronic Control Gear “ECG”. TPH 2/36W
High Frequency Dimmable Electronic Control Gear “ECG”.

220 - 240V , 50 / 60 Hz
Voltage / Frequency
. “Other Voltages upon request”

Cable Entry 1[22 mm ‘ hole on top. “E[tra knock-out holes upon request”

18, 36 58 watt T8/T26 Fluorescent for Normal Start “NS”, Electronic Start “DEOS” or Electronic High Frequency
17 32 watt T8 Fluorescent for Electronic High Frequency “HF” Ballast “EB”. 14, 28 35 watt FH T5/T16 Fluorescent
Lamps for Electronic High Frequency “HF” Ballast “EB”. 24, 49, 54 80 watt F4 T5/T16 Fluorescent for Electronic High
Frequency “HF” Ballast “EB”. “Other lamps (T5/T16 – T8/T26 – T12/T38 – TCL - TC-DE – TC-TE upon request
¿tting housing dimensions subMect to changes accordingly”

3 Hours duration Emergency Unit “EMU” with battery pack Maintained “/M” or Non-Maintained “/NM” for one lamp,
Emergency Unit and for various lamp types and voltage networks combinations.
“Additional Emergency Units to operate more than one lamp on request”

138
Hygienic Aluminium V-Louvers IP65

SERIES : VAHC/VAHCM

Technical Data
To Order : follow the sequence mr+gt+ht - ln / ls – cgt – vh – cgm - emu
Physical Characteristics

Frequency

Accessories

Emergency
Grid Type

Voltage
Reference

Lamp

Optional
Housing

Size
Number

Control
CM

Power
Factor
Model

Lamp

Gear
Type

Type

Unit
M I C
(concealed
(metric) (imperial) (concealed)
metric)
L W L W L W L W H
mm mm mm mm mm mm mm mm mm watt V / Hz

- - - - 624 324 600 300 1


14
- - - - 624 324 600 300 2 17

- - - - 624 624 600 600 3 18 NS


24 Normal
Start FTB
- - - - 624 624 600 600 4
None Fused
(standard Terminal
- - - - 1226 324 1200 300 1 Block
plastic
28 DEOS
end-caps)
- - - - 1226 324 1200 300 2 32 Electronic
3/NM
Starter
- - - - 1226 624 1200 600 3 36 HPF 3 hours
TRW
54 High Non-
G Temperature
- - - - 1226 624 1200 600 4
220 - 240V Power Maintained
(for CRS Resistant
Factor
VAH 100 end-bo[) Wire
- - - - 1526 324 1500 300 1 EB
35 Electronic 50 / 60 Hz
3/M
- - - - 1526 324 1500 300 2 High
49 HF 3 hours
Frequency TW
High Maintained
- - - - 1526 624 1500 600 3 58 Through
Frequency
80 Wire
Suitable to be used in: Hygienic areas with low dust particles and germ counts, e.g. hospital, operating theaters, pharmacies,
Applications - - - - 1526 624 1500 600 4
laboratories, pharmaceutical, food processing, patients rooms, etc… EBD
Dimmable
- - - - 624 324 600 300 1
Made of press welded Cold Rolled Steel “CRS” sheet of tight construction to prevent light leakage, diffuser frame Electronic
35 High
made of Plain Aluminum, all metal parts pre-treated with a full degreasing and phosphate process painted in stove
Housing - - - - 624 324 600 300 2 49 Frequency
enameled white baked epo[y polyester mi[-powder to ensure high reÀectance of painted surfaces. CRS
“Other color ¿nishes upon request” end-bo[ 58
- - - - 624 624 600 600 3
80
V shaped specular anodized aluminum mirror louvers, with stepped surface strip aluminum cross-blades. Louvers
- - - - 624 624 600 600 4
¿[ed on white aluminum frame incorporates tempered glass or polycarbonate hygienic layer, special UV resistant
gasket seal ensures tight ¿t between body and diffuser, suspension kit supplied for easy maintenance, also for easy
Light Controller
installation, a suspension system consisting of a special kit adMustable from inside the luminaire can be supplied on
request. Hygienic layer features UV resistant, High resistant for mechanical impact and high resistant for most of the
disinfectant chemicals used in operation theatre rooms, delivery rooms, etc…
Photometrics & Dimensions
Mounting Concealed. Suitable for ¿[ in Metric or Imperial or Concealed standard T-pro¿le false ceiling.

High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.


Control Gear High Frequency Electronic Control Gear “ECG”. VAH 4/36W
High Frequency Dimmable Electronic Control Gear “ECG”.

220 - 240V , 50 / 60 Hz
Voltage / Frequency
“Other Voltages upon request”

Cable Entry 1[22 mm ‘ hole on top. “E[tra knock-out holes upon request”

18, 36 58 watt T8/T26 Fluorescent for Normal Start “NS”, Electronic Start “DEOS” or Electronic High Frequency
17 32 watt T8 Fluorescent for Electronic High Frequency “HF” Ballast “EB”. 14, 28 35 watt FH T5/T16 Fluorescent
Lamps for Electronic High Frequency “HF” Ballast “EB”. 24, 49, 54 80 watt F4 T5/T16 Fluorescent for Electronic High
Frequency “HF” Ballast “EB”. “Other lamps (T5/T16 – T8/T26 – T12/T38 – TCL - TC-DE – TC-TE upon request
¿tting housing dimensions subMect to changes accordingly”

3 Hours duration Emergency Unit “EMU” with battery pack Maintained “/M” or Non-Maintained “/NM” for one lamp,
Emergency Unit and for various lamp types and voltage networks combinations.
“Additional Emergency Units to operate more than one lamp on request”

140
Hygienic Plain Aluminium V-Louvers IP65

SERIES : VSHC/VSHCM

Technical Data
To Order : follow the sequence mr+gt+ht - ln / ls – cgt – vh – cgm - emu
Physical Characteristics

Frequency

Accessories
Grid Type

Emergency
Voltage
Reference

Lamp

Optional
Housing

Size
Number
CM

Control

Power
Factor
Model

Lamp
M I C

Gear
Type

Type

Unit
(concealed
(metric) (imperial) (concealed)
metric)
L W L W L W L W H
mm mm mm mm mm mm mm mm mm watt V / Hz

- - - - 624 324 600 300 1


14
- - - - 624 324 600 300 2 17
18
- - - - 624 624 600 600 3 NS
20 Normal
24 Start FTB
- - - - 624 624 600 600 4
None Fused
(standard Terminal
- - - - 1226 324 1200 300 1
plastic 28 Block
end-caps) 32 DEOS
- - - - 1226 324 1200 300 2 Electronic
36 3/NM
Starter HPF
- - - - 1226 624 1200 600 3 3 hours
40 High TRW
Non-
G Power Temperature
- - - - 1226 624 1200 600 4 54 220 - 240V Maintained
(for CRS Factor Resistant
VSH 100 end-bo[) Wire
- - - - 1526 324 1500 300 1 EB
Electronic 50 / 60 Hz
35 3/M
- - - - 1526 324 1500 300 2 High HF
49 3 hours
Frequency High TW
58 Maintained
- - - - 1526 624 1500 600 3 Frequency Through
80 Wire
Suitable to be used in: Hygienic areas with low dust particles and germ counts, e.g. hospital, operating theaters, pharmacies,
Applications - - - - 1526 624 1500 600 4
laboratories, pharmaceutical, food processing, patients rooms, etc… EBD
Dimmable
- - - - 624 324 600 300 1 Electronic
Made of press welded Cold Rolled Steel “CRS” sheet of tight construction to prevent light leakage, diffuser frame
35 High
made of Plain Aluminum, all metal parts pre-treated with a full degreasing and phosphate process painted in stove - - - - 624 324 600 300 2
Housing CRS 49 Frequency
enameled white baked epo[y polyester mi[-powder to ensure high reÀectance of painted surfaces.
“Other color ¿nishes upon request” end-bo[ 58
- - - - 624 624 600 600 3
80
V shaped matt anodized aluminum louvers, with strip plain aluminum cross-bafÀe. Louvers ¿[ed on white - - - - 624 624 600 600 4
aluminum frame incorporates tempered glass or polycarbonate hygienic layer, special UV resistant gasket seal
ensures tight ¿t between body and diffuser, suspension kit supplied for easy maintenance, also for easy installation,
Light Controller
a suspension system consisting of a special kit adMustable from inside the luminaire can be supplied on request.
Hygienic layer features UV resistant, High resistant for mechanical impact and high resistant for most of the
disinfectant chemicals used in operation theatre rooms, delivery rooms, etc…
Photometrics & Dimensions
Mounting Concealed. Suitable for ¿[ in Metric or Imperial or Concealed standard T-pro¿le false ceiling.

High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.


Control Gear High Frequency Electronic Control Gear “ECG”. VSH 2/36W
High Frequency Dimmable Electronic Control Gear “ECG”.

220 - 240V , 50 / 60 Hz
Voltage / Frequency
. “Other Voltages upon request”

Cable Entry 1[22 mm ‘ hole on top. “E[tra knock-out holes upon request”

18, 36 58 watt T8/T26 Fluorescent for Normal Start “NS”, Electronic Start “DEOS” or Electronic High Frequency
17 32 watt T8 Fluorescent for Electronic High Frequency “HF” Ballast “EB”. 14, 28 35 watt FH T5/T16 Fluorescent
Lamps for Electronic High Frequency “HF” Ballast “EB”. 24, 49, 54 80 watt F4 T5/T16 Fluorescent for Electronic High
Frequency “HF” Ballast “EB”. “Other lamps (T5/T16 – T8/T26 – T12/T38 – TCL - TC-DE – TC-TE upon request
¿tting housing dimensions subMect to changes accordingly”

3 Hours duration Emergency Unit “EMU” with battery pack Maintained “/M” or Non-Maintained “/NM” for one lamp,
Emergency Unit and for various lamp types and voltage networks combinations.
“Additional Emergency Units to operate more than one lamp on request”

142
IP65
Hygienic White Steel V-Louvers
SERIES : VWHC/VWHCM

Technical Data
To Order : follow the sequence mr+gt+ht - ln / ls – cgt – vh – cgm - emu
Physical Characteristics

Frequency

Accessories

Emergency
Voltage
Grid Type

Reference

Lamp

Optional
Housing

Size
Number

Control

Power
Factor
Model

Lamp
CM

Gear
Type

Type

Unit
M I C
(concealed
(metric) (imperial) (concealed)
metric)
L W L W L W L W H
mm mm mm mm mm mm mm mm mm watt V / Hz

- - - - 624 324 600 300 1


14
- - - - 624 324 600 300 2 17

- - - - 624 624 600 600 3 18 NS


24 Normal
Start FTB
- - - - 624 624 600 600 4
None Fused
(standard Terminal
- - - - 1226 324 1200 300 1 Block
plastic
28 DEOS
end-caps)
- - - - 1226 324 1200 300 2 32 Electronic
HPF 3/NM
Starter
- - - - 1226 624 1200 600 3 36 High 3 hours
TRW
54 Power Non-
G Temperature
- - - - 1226 624 1200 600 4
220 - 240V Factor Maintained
(for CRS Resistant
VWH 100 end-bo[) Wire
- - - - 1526 324 1500 300 1 EB
Electronic 50 / 60 Hz
35 HF 3/M
- - - - 1526 324 1500 300 2 High
49 High 3 hours
Frequency TW
Frequency Maintained
- - - - 1526 624 1500 600 3 58 Through
80 Wire
Suitable to be used in: Hygienic areas with low dust particles and germ counts, e.g. hospital, operating theaters, pharmacies,
Applications - - - - 1526 624 1500 600 4
laboratories, pharmaceutical, food processing, patients rooms, etc… EBD
Dimmable
Made of press welded Cold Rolled Steel “CRS” sheet of tight construction to prevent light leakage, diffuser frame - - - - 624 324 600 300 1 Electronic
made of Plain Aluminum, all metal parts pre-treated with a full degreasing and phosphate process painted in stove 35 High
Housing - - - - 624 324 600 300 2 49 Frequency
enameled white baked epo[y polyester mi[-powder to ensure high reÀectance of painted surfaces. CRS
“Other color ¿nishes upon request” end-bo[ 58
- - - - 624 624 600 600 3
V shaped steel sheets louvers, with strip cross-bafÀe all painted white. Louvers ¿[ed on white aluminum frame 80
incorporates tempered glass or polycarbonate hygienic layer, special UV resistant gasket seal ensures tight ¿t - - - - 624 624 600 600 4
between body and diffuser, suspension kit supplied for easy maintenance, also for easy installation, a suspension
Light Controller
system consisting of a special kit adMustable from inside the luminaire can be supplied on request. Hygienic layer
features UV resistant, High resistant for mechanical impact and high resistant for most of the disinfectant chemicals
used in operation theatre rooms, delivery rooms, etc…
Photometrics & Dimensions
Mounting Concealed. Suitable for ¿[ in Metric or Imperial or Concealed standard T-pro¿le false ceiling.

High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.


Control Gear High Frequency Electronic Control Gear “ECG”. VWH 2/36W
High Frequency Dimmable Electronic Control Gear “ECG”.

220 - 240V , 50 / 60 Hz
Voltage / Frequency
“Other Voltages upon request”

Cable Entry 1[22 mm ‘ hole on top. “E[tra knock-out holes upon request”

18, 36 58 watt T8/T26 Fluorescent for Normal Start “NS”, Electronic Start “DEOS” or Electronic High Frequency
17 32 watt T8 Fluorescent for Electronic High Frequency “HF” Ballast “EB”. 14, 28 35 watt FH T5/T16 Fluorescent
Lamps for Electronic High Frequency “HF” Ballast “EB”. 24, 49, 54 80 watt F4 T5/T16 Fluorescent for Electronic High
Frequency “HF” Ballast “EB”. “Other lamps (T5/T16 – T8/T26 – T12/T38 – TCL - TC-DE – TC-TE upon request
¿tting housing dimensions subMect to changes accordingly”

3 Hours duration Emergency Unit “EMU” with battery pack Maintained “/M” or Non-Maintained “/NM” for one lamp,
Emergency Unit and for various lamp types and voltage networks combinations.
“Additional Emergency Units to operate more than one lamp on request”

144
Panel Opal
SERIES : POC
IP40
Technical Data
To Order : follow the sequence mr - ln / ls - cgt - v/h - pf - emu

Physical Characteristics

Frequency
Housing Type

Voltage
Lamp

Emergency
Size
Reference

Number

Control

Power
Factor
Model

Lamp

Gear
Type

Unit
L W H

watt V / Hz mm mm mm

1 14 615 115 92
17
18
2 24 615 216 60
NS
Normal
Start 3/NM
1 28 3 hours 1224 115 92
32 DEOS Non-Maintained
HPF
Electronic
36 High
Starter
Power
2 54 220 - 240V 1224 216 60
Factor
CRS
POC EB
end-bo[
Electronic
1 35 High 50 / 60 Hz 1524 115 92
49 Frequency
HF
58 High
EBD 3/M
Applications Suitable to be used in: Toilets, washing and ablution areas and general lighting application. 2 80 Dimmable
Frequency
3 hours 1524 216 60
Electronic Maintained
Made of press welded Cold Rolled Steel “CRS” sheet of tight construction to prevent light leakage, all metal High
Frequency
parts pre-treated with a full degreasing and phosphate process, painted in stove enameled white baked epo[y 1 36L 615 115 92
Housing
polyester mi[-powder to ensure high reÀectance of painted surfaces.
“Other color ¿nishes upon request” 40L

2 55L 615 216 60


Light Controller .One piece e[truded methacrylate opal diffuser

Mounting Recessed, suitable for ¿[ in Strip ceiling.


Photometrics & Dimensions
High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.
Control Gear High Frequency Electronic Control Gear “ECG”.
High Frequency Dimmable Electronic Control Gear “ECG”.
POC 1/36W
220 - 240V , 50 / 60 Hz
Voltage / Frequency
“Other Voltages upon request”

1[22 mm ‘ hole on top.


Cable Entry
“E[tra knock-out holes upon request”
18, 36 58 watt T8/T26 Fluorescent for Normal Start “NS”, Electronic Start “DEOS” or Electronic High
Frequency “HF” Ballast “EB”.
17 32 watt T8 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
Lamps 14, 28 35 watt FH T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
24, 49, 54 80 watt F4 T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
”Other lamps (T5/T16 – T8/T26 – T12/T38 – TCL - TC-DE – TC-TE upon request ¿tting housing dimensions
subMect to changes accordingly”

3 Hours duration Emergency Unit “EMU” with battery pack Maintained “/M” or Non-Maintained “/NM” for one
Emergency Unit lamp, and for various lamp types and voltage networks combinations.
“Additional Emergency Units to operate more than one lamp on request”

146
Panel Prismatic
SERIES : PPC
IP40
Technical Data

To Order : follow the sequence mr - ln / ls - cgt - v/h - pf - emu


Physical Characteristics

Frequency
Housing Type

Voltage

Emergency
Lamp
Reference

Size
Number

Control

Power
Factor
Model

/
Lamp

Gear
Type

Unit
L W H

watt V / Hz mm mm mm

14
1 17 615 115 92

18

2 20 615 216 60
NS
24 Normal
Start 3/NM
28 3 hours
1 32 DEOS Non-Maintained 1224 115 92

36 Electronic
Starter HPF
2 40 High 1224 216 60
220 - 240V
54 Power
CRS
PPC EB Factor
end-bo[
Electronic
1 35
High 50 / 60 Hz 1524 115 92
49 Frequency
58
2 EBD HF 3/M 1524 216 60
80 Dimmable High 3 hours
Applications Suitable to be used in: Toilets, washing and ablution areas and general lighting application. Electronic Frequency Maintained
High
1 36L Frequency 615 115 92
Made of press welded Cold Rolled Steel “CRS” sheet of tight construction to prevent light leakage, all metal
parts pre-treated with a full degreasing and phosphate process, painted in stove enameled white baked epo[y 40L
Housing
polyester mi[-powder to ensure high reÀectance of painted surfaces. 2 615 216 60
55L
“Other color ¿nishes upon request”

Light Controller One piece e[truded methacrylate prismatic diffuser.

Mounting Recessed, suitable for ¿[ in strip ceiling.


Photometrics & Dimensions
High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.
Control Gear High Frequency Electronic Control Gear “ECG”.
High Frequency Dimmable Electronic Control Gear “ECG”.
PPC 2/18W
220 - 240V , 50 / 60 Hz
Voltage / Frequency
“Other Voltages upon request”

1[22 mm ‘ hole on top.


Cable Entry
“E[tra knock-out holes upon request”
18, 36 58 watt T8/T26 Fluorescent for Normal Start “NS”, Electronic Start “DEOS” or Electronic High
Frequency “HF” Ballast “EB”.
17 32 watt T8 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
Lamps 14, 28 35 watt FH T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
24, 49, 54 80 watt F4 T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
”Other lamps (T5/T16 – T8/T26 – T12/T38 – TCL - TC-DE – TC-TE upon request ¿tting housing dimensions
subMect to changes accordingly”

3 Hours duration Emergency Unit “EMU” with battery pack Maintained “/M” or Non-Maintained “/NM” for one
Emergency Unit lamp, and for various lamp types and voltage networks combinations.
“Additional Emergency Units to operate more than one lamp on request”

148
Panel White Dished Plate
SERIES : PWC
IP20
Technical Data
To Order : follow the sequence mr - ln / ls - cgt - v/h - pf - emu

Physical Characteristics

Frequency
Housing Type

Voltage

Emergency
Lamp
Reference

Size
Number

Control

Power
Factor
Model

/
Lamp

Gear
Type

Unit
L W H

watt V / Hz mm mm mm

1 14 615 115 60
17
18
2 24 NS 615 216 90
Normal
Start 3/NM
28 3 hours
1 DEOS Non-Maintained 1224 115 60
32 Electronic HPF
36 Starter High
2 Power 1224 216 90
54 220 - 240V
Factor
CRS
PWC EB
end-bo[
Electronic
1 35
High 50 / 60 Hz 1524 115 60
49 Frequency
58 HF
2 EBD High 3/M 1524 216 90
80 Dimmable Frequency 3 hours
Electronic Maintained
Applications Suitable to be used in: Toilets, washing and ablution areas and general lighting application. High
1 36L Frequency 615 115 60
Made of press welded Cold Rolled Steel “CRS” sheet of tight construction to prevent light leakage, all metal 40L
parts pre-treated with a full degreasing and phosphate process, painted in stove enameled white baked epo[y
Housing 2 55L 615 216 90
polyester mi[-powder to ensure high reÀectance of painted surfaces.
“Other color ¿nishes upon request”

Dished plate white ¿nish metallic louvers.


Light Controller

Mounting Recessed, suitable for ¿[ in panel ceiling.


Photometrics & Dimensions
High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.
Control Gear High Frequency Electronic Control Gear “ECG”.
High Frequency Dimmable Electronic Control Gear “ECG”.
PWC 2/36W
220 - 240V , 50 / 60 hz
Voltage / Frequency
“Other Voltages upon request”

1[22 mm ‘ hole on top.


Cable Entry PWC 2/36w
“E[tra knock-out holes upon request”
18, 36 58 watt T8/T26 Fluorescent for Normal Start “NS”, Electronic Start “DEOS” or Electronic High
Frequency “HF” Ballast “EB”.
17 32 watt T8 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
Lamps 14, 28 35 watt FH T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
24, 49, 54 80 watt F4 T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
”Other lamps (T5/T16 – T8/T26 – T12/T38 – TCL - TC-DE – TC-TE upon request ¿tting housing dimensions
subMect to changes accordingly”

3 Hours duration Emergency Unit “EMU” with battery pack Maintained “/M” or Non-Maintained “/NM” for one
Emergency Unit lamp, and for various lamp types and voltage networks combinations.
“Additional Emergency Units to operate more than one lamp on request”

150
Industrial
Rectangular Batten

RECTANGULAR BATTEN RECTANGULAR BATTEN WATERPROOF STRIP


REFLECTOR

SB 156-157 SBR 158-159 SWB 160-161

Aluminium Pro¿le

CONICAL ALUMINIUM

RAP 162-163

INDUSTRIAL HIGHBAY INDUSTRIAL HIGHBAY ORNAMENTAL HIGHBAY ORNAMENTAL HIGHBAY


ALUMINIUM ALUMINIUM ALUMINIUM ALUMINIUM

4NE 164-165 HB1 166-167 HB100 168-169 HBP 170-171

ORNAMENTAL LOWBAY ORNAMENTAL LOWBAY


ALUMINIUM PRISMATIC

LB100 172-173 LBP 174-175


Rectangular Batten
SERIES : SB
IP20
Technical Data
To Order : follow the sequence mr - ln / ls - cgt - v/h - pf - acc - emu
Physical Characteristics

Frequency

Accessories
Voltage

Emergency
Reference

Lamp

Optional
Size
Number

Control

Power
Factor
Model

Lamp

Gear
Type

Unit
L W H

watt V / Hz mm mm mm
1 14 575 46 40
2 14 575 78 40
1 18 622 75 57
NS
2 18 Normal 622 305 57
3/NM
Start FTB
4 18 3 hours 622 210 57
Fused
Non-
1 24 DEOS Terminal 575 46 40
HPF Maintained
Electronic Block
2 24 High 575 78 40
Starter
Power
TRW
1 28 220 - 240V Factor 1175 46 40
Temperature
SB
2 28 EB Resistant 1175 78 40
Electronic Wire
1 36 High 50 / 60 Hz 1233 75 57
2 36 Frequency TW 1233 101 57
HF
Through
3 36 High 1233 140 57
EBD Wire
Frequency 3/M
4 36 Dimmable 1233 210 57
3 hours
Electronic
1 58 Maintained 1533 75 57
High
Frequency
2 58 1533 101 57

Applications Suitable to be used in: of¿ces, clinics, education premises, circulation area, cove lighting general indoor application. 1 54 1175 46 40
2 54 1175 78 40
Made of press welded Cold Rolled Steel “CRS” sheet of tight construction to prevent light leakage, all metal parts pre-
treated with a full degreasing and phosphate process, painted in stove enameled white baked epo[y polyester mi[-
Housing
powder to ensure high reÀectance of painted surfaces.
“Other color ¿nishes upon request”

Light Controller N/A

Mounting Surface

Photometrics & Dimensions


High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.
Control Gear High Frequency Electronic Control Gear “ECG”.
High Frequency Dimmable Electronic Control Gear “ECG”.

SB 2/36W
220 - 240V , 50 / 60 hz
Voltage / Frequency
“Other Voltages upon request”

1[22 mm ‘ hole on top.


Cable Entry
“E[tra knock-out holes upon request”
18, 36 58 watt T8/T26 Fluorescent for Normal Start “NS”, Electronic Start “DEOS” or Electronic High Frequency
“HF” Ballast “EB”.
17 32 watt T8 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
Lamps 14, 28 35 watt FH T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
24, 49, 54 80 watt F4 T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
“Other lamps (T5/T16 – T8/T26 – T12/T38 – TCL - TC-DE – TC-TE upon request ¿tting housing dimensions subMect
to changes accordingly”

3 Hours duration Emergency Unit “EMU” with battery pack Maintained “/M” or Non-Maintained “/NM” for one lamp,
Emergency Unit and for various lamp types and voltage networks combinations.
“Additional Emergency Units to operate more than one lamp on request”

156
Rectangular Batten Reflector
SERIES : SBR
IP20
Technical Data
To Order : follow the sequence mr - ln / ls - cgt - v/h - pf - acc - emu
Physical Characteristics

Frequency

Accessories
Voltage

Emergency
Reference

Lamp

Optional
Size
Number

Control

Power
Factor
Model

Lamp

Gear
Type

Unit
L W H H1

watt V / Hz mm mm mm mm
1 14 575 46 40 95
2 14 575 78 40 95
1 18 622 75 57 112
NS
2 18 Normal 622 305 57 112
3/NM
Start FTB
4 18 3 hours 622 210 57 112
Fused
Non-
1 24 DEOS Terminal 575 46 40 95
HPF Maintained
Electronic Block
2 24 High 575 78 40 95
Starter
Power
TRW
1 28 220 - 240V Factor 1175 46 40 95
Temperature
SBR
2 28 EB Resistant 1175 78 40 95
Electronic Wire
1 36 High 50 / 60 Hz 1233 75 57 112
2 36 Frequency TW 1233 101 57 112
HF
Through
3 36 High 1233 140 57 112
EBD Wire
Frequency 3/M
4 36 Dimmable 1233 210 57 112
3 hours
Electronic
1 58 Maintained 1533 75 57 112
High
Frequency
2 58 1533 101 57 112

Applications Suitable to be used in: of¿ces, clinics, education premises, circulation area, general indoor application. 1 54 1175 46 40 95
2 54 1175 78 40 95
Made of press welded Cold Rolled Steel “CRS” sheet of tight construction to prevent light leakage, all metal parts pre-
treated with a full degreasing and phosphate process, painted in stove enameled white baked epo[y polyester mi[-
Housing
powder to ensure high reÀectance of painted surfaces.
“Other color ¿nishes upon request”

Light Controller CRS Painted in white

Mounting Surface

Photometrics & Dimensions


High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.
Control Gear High Frequency Electronic Control Gear “ECG”.
High Frequency Dimmable Electronic Control Gear “ECG”.

SBR 2/36W
220 - 240V , 50 / 60 hz
Voltage / Frequency
“Other Voltages upon request”

1[22 mm ‘ hole on top.


Cable Entry
“E[tra knock-out holes upon request”
18, 36 58 watt T8/T26 Fluorescent for Normal Start “NS”, Electronic Start “DEOS” or Electronic High Frequency
“HF” Ballast “EB”.
17 32 watt T8 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
Lamps 14, 28 35 watt FH T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
24, 49, 54 80 watt F4 T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
“Other lamps (T5/T16 – T8/T26 – T12/T38 – TCL - TC-DE – TC-TE upon request ¿tting housing dimensions subMect
to changes accordingly”

3 Hours duration Emergency Unit “EMU” with battery pack Maintained “/M” or Non-Maintained “/NM” for one lamp,
Emergency Unit and for various lamp types and voltage networks combinations.
“Additional Emergency Units to operate more than one lamp on request”

158
Weatherproof Strip
SERIES : SWB
IP65
Technical Data
To Order : follow the sequence mr - ln / ls - cgt - v/h - pf - acc - emu

Physical Characteristics

Frequency
Voltage
Lamp
Size

Accessories

Emergency
/
Reference

Optional
Number

Control

Power
Factor
Model

Lamp

Gear
Type

Unit
L W H

watt V / Hz mm mm mm

1 17 NS 645 65 135
Normal
Start
2 18 645 155 135
DEOS HPF
Electronic High
Starter Power
1 32 220 - 240V Factor 1255 65 135
EB
SWB ---
Electronic
2 36 High 50 / 60 Hz 1255 155 135
Frequency
Suitable to be used in: of¿ces, clinics, education premises, circulation area, warehouses general indoor and outdoor HF
Applications 1 EBD High 1555 65 135
application.
Dimmable Frequency
Made of grey ¿berglass reinforced polyester resin. 58 Electronic
High
Body with sealed grommet at each end. 2 1555 155 135
Frequency
Housing Cover-plate supporting the electrical equipment and held by self retaining nuts.
Sealing gasket made of durable high density polyurethane poured on the body.
Turret lamp holder with sealing screw grip collars.

Light Controller “Optional protection tube (40mm) made of polycarbonate”

Mounting Surface
Photometrics & Dimensions
High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.
Control Gear High Frequency Electronic Control Gear “ECG”.
High Frequency Dimmable Electronic Control Gear “ECG”.
SWB 2/36W
220 - 240V , 50 / 60 hz
Voltage / Frequency
“Other Voltages upon request”

Cable Entry Two holes at each side.

18, 36 58 watt T8/T26 Fluorescent for Normal Start “NS”, Electronic Start “DEOS” or Electronic High Frequency
Lamps
“HF” Ballast “EB”.

160
Conical Aluminium
SERIES : RAP
IP65
Technical Data
To Order : follow the sequence mr - ln / ls - cgt - v/h - pf - acc - emu

Physical Characteristics

Frequency
Voltage
Lamp

Accessories
Size

Emergency
Reference

Optional
/
Number

Control

Power
Factor
Model

Lamp

Gear
Type

Unit
L W H

watt V / Hz mm mm mm

14
1 628 133 121
17
18 NS
2 Normal 3/NM 628 133 121
24
Start 3 hours
28 Non-
1 HPF FTB 1238 133 121
DEOS Maintained
32 High Fused
Electronic
Power Terminal
36 Starter
2 Factor Block 1238 133 121
54 220 - 240V
EB
RAP TRW
Electronic
1 Temperature 1538 133 121
High 50 / 60 Hz Resistant
58 Frequency
HF Wire
2 High 1538 133 121
Applications Suitable to be used in: of¿ces, clinics, education premises, circulation area general indoor application. EBD
Frequency
Dimmable 3/M
Electronic 3 hours
Made of anodized aluminum in natural ¿nish. Aluminum end-plates and steel gear tray treated with a full degreasing 1 18D 183 133 121
High Maintained
and phosphating process and ¿nish in white stove backing enamel ensuring high Frequency
Housing reÀectance of painted surfaces.
“Other color ¿nishes upon request” 1 26D 224 133 121
“ WG “ can be supplied with Wire Guard upon request
“ G “ one piece clear or obscured toughened tempered glass vandal proof,
Light Controller “ L “ one piece clear or opal le[an sheet. Diffuser is inserted into the body by mean of two lateral grooves and
secured by two aluminum end-plates. Specular aluminum reÀector

Mounting Surface on wall or ceiling, or with adMustable aluminum or galvanized bracket


Photometrics & Dimensions
High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.
Control Gear High Frequency Electronic Control Gear “ECG”.
High Frequency Dimmable Electronic Control Gear “ECG”.
RAP 2/36W
220 - 240V , 50 / 60 hz
Voltage / Frequency
“Other Voltages upon request”

Cable Entry 1[22 mm ‘ hole on top. “E[tra knock-out holes upon request”

18, 36 58 watt T8/T26 Fluorescent for Normal Start “NS”, Electronic Start “DEOS” or Electronic High Frequency
“HF” Ballast “EB”.
17 32 watt T8 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
14, 28 35 watt FH T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
Lamps
24, 49, 54 80 watt F4 T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
“Other lamps (T5/T16 – T8/T26 – T12/T38 – TCL - TC-DE – TC-TE)
upon request ¿tting housing dimensions subMect to changes
accordingly”

3 Hours duration Emergency Unit “EMU” with battery pack Maintained “/M” or Non-Maintained “/NM” for one lamp,
Emergency Unit and for various lamp types and voltage networks combinations.
“Additional Emergency Units to operate more than one lamp on request”

162
Industrial Highbay Aluminium IP54

SERIES : QNE IP20

Technical Data
To order : follow the sequence mr - ln / ls - lt - lsr - v/h - pf – acc - emu
Physical

Lamp Screw Reference


Characteristics

Frequency
Voltage

Accessories
Lamp

Emergency
Lamp Type
Reference

Size

Optional
Number

Control

Power
Factor
Model

Lamp

Gear
Type

Unit
D W H

watt V / Hz mm mm mm

HME
Conventional
( high pressure
4NE 50 Control Gear 420 -- 584
mercury )
( elliptic ) LPF
70 constructed of
Low
HIE Power
80 - choke ballast
( metal halide ) Factor - remote -
E27 for ASL
( elliptic )
100 (mercury Au[iliary
220 - 240V 3/NM
vapor) Startup
HIT 50w 12v
1 125 Lamp
( Metal halide ) GY6,35
( ma[ 230w )
( tubular ) 50 / 60 Hz 3 hours
150 - choke ballast ( B15d /
Non-
E40 + E27 )
HSE HPF Maintained
175 igniter
(high pressure sodium ) High
for
( elliptic ) Power
4NEG 250 (metal halide) 400 -- 579
Applications Suitable to be used in: Gyms, sport centers, commercial premises, warehouses and stores, etc… Factor

HST
400 (sodium vapor)
(high pressure sodium )
Made of press welded Cold Rolled Steel “CRS” sheet of tight construction all metal parts pre-treated with a full ( tubular )
degreasing and phosphating process, painted in stove enameled white baked epo[y polyester mi[-powder.
Housing
Screw type ceramic lamp holder
“Other color ¿nishes upon request”
ReÀector is made of high purity aluminum anodized matt silver.
Tempered safety glass for high protection degree is available on request,
The glass is tenable to the reÀector with UV balanced silicon gasket
Light Controller
by means of stainless steel ring and ¿[ing screw.
“ / CG “ Clear tempered glass
“ / FG “ Frosted tempered glass
Photometrics & Dimensions
Mounting Surface / Pendant.

Control Gear High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.
QNE 400W HIE

220 - 240V , 50 / 60 Hz
Voltage / Frequency
“Other Voltages upon request”

Cable Entry 1[22 mm ‘ hole on top.

125w, 175w, 250w , 400w High Pressure Mercury HME (MBF)


Mercury-Tungsten blended self ballasted (no control gear required)
150w, 175w, 250w, 400w Metal Halide HIE/HIT (Edison Base)
Lamps
150w, 250w, 400w High Pressure Sodium HSE/HST (Edison Base)
“Other HID lamps upon request”

164
Industrial Highbay Prismatic IP44
SERIES : QNEP
IP20 W/O Cover

Technical Data
To order : follow the sequence mr - ln / ls - lt - lsr - v/h - pf – acc - emu

Physical Characteristics

Frequency
Voltage
Lamp Screw

Accessories

Emergency
Lamp

Lamp Type
Reference

Reference
Size
Number

Control

Power
Factor
Model

/
Lamp

Gear
Type

Unit
D W H

watt V / Hz mm mm mm

HME
Conventional
( high pressure
Control Gear
50 mercury )
( elliptic ) E27
constructed of
70
HIE
- choke ballast
80 ( metal halide )
for
( elliptic )
(mercury
100 HPF
vapor) 220 - 240V
HIT High
QNEP 1 -- -- 410 -- 584
125 ( Metal halide ) Power
50 / 60Hz
( tubular ) Factor
- choke ballast
150
+
HSE
igniter
175 (high pressure sodium)
for
( elliptic )
(metal halide)
250
&
HST E40
(sodium vapor)
(high pressure sodium)
( tubular )

Applications Suitable to be used in: Gyms, sport centers, commercial premises, warehouses and stores, etc…

Made of press welded Cold Rolled Steel “CRS” sheet of tight construction all metal parts pre-treated with a full
degreasing and phosphating process, painted in stove enameled white baked epoxy polyester mix-powder.
Housing
Screw type ceramic lamp holder
“Other color ¿nishes upon request”

ReÀector is made of UV stabilized prismatic polycarbonate.


Light Controller
Protection prismatic polycarbonate cover available on request.

Mounting Surface / Pendant.


Photometrics & Dimensions
Control Gear High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.

QNEP 250W HSE


220v - 240v, 50 / 60Hz.
Voltage / Frequency
“Other Voltages upon request”

Cable Entry 1x22 mm Ø hole on top.

125w, 175w, 250w


160w, 250w
Mercury-Tungsten blended self ballasted (no control gear required)
Lamps
150w, 175w, 250w
150w, 250w

“Other HID lamps upon request”

166
Industrial Highbay Aluminium IP65
SERIES : HB1

Technical Data
To order : follow the sequence mr - ln / ls - lt - lsr - v/h - pf – acc - emu
Physical
Characteristics

Frequency
Voltage
Lamp Screw

Accessories

Emergency
Lamp

Lamp Type
Reference

Reference
Size
Number

Control

Power
Factor
Model

/
Lamp

Gear
Type

Unit
D W H

watt V / Hz mm mm mm

HME Conventional
( high pressure Control Gear
50
mercury )
( elliptic ) E27 constructed of LPF
70
Low
HIE - choke ballast Power
80
( metal halide ) for Factor - remote -
ASL
( elliptic ) (mercury
100 Auxiliary
vapor) 3/NM
220 - 240V Startup
HIT 50w 12v
HB1 1 125 Lamp 490 -- 510
( Metal halide ) GY6,35
50 / 60Hz ( max 230w )
( tubular ) - choke ballast 3 hours
150 ( B15d /
+ Non-
E27 )
HSE igniter HPF Maintained
175
(high pressure sodium) for High
( elliptic ) (metal halide) Power
250
& Factor
HST E40 (sodium
400
(high pressure sodium) vapor)
( tubular )

Applications Suitable to be used in: Gyms, sport centers, commercial premises, warehouses and stores, etc…

Made of die-cast aluminum –appliance body- with cooling ¿ns on top-cover, Painted black
Housing
“Other color ¿nishes upon request”

Shaped reÀector in 99.8 s aluminum oxidized, anode process polished for high light output.
Tempered safety glass heat resistant and shock-proof for high protection,
Light Controller
The glass is tenable to the reÀector with UV balanced silicon gasket
by means of securing nickel coated steel ring with locking latch .

Mounting Surface / Pendant. Photometrics & Dimensions


Control Gear High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.
HB1 400W HIE
220v - 240v, 50 / 60Hz.
Voltage / Frequency
“Other Voltages upon request”

Cable Entry 1x22 mm Ø hole on top.

125w, 175w, 250w , 400w High Pressure Mercury HME (MBF)

160w, 250w, 500w High Pressure Mercury HME (MBF)


Mercury-Tungsten blended self ballasted (no control gear required)
Lamps
150w, 175w, 250w, 400w Metal Halide HIE/HIT (Edison Base)
150w, 250w, 400w High Pressure Sodium HSE/HST (Edison Base)

“Other HID lamps upon request”

168
Ornamental Highbay Aluminium IP65
SERIES : HB100
IP20 W/O Cover

Technical Data
To order : follow the sequence mr - ln / ls - lt - lsr - v/h - pf – acc - emu
Physical
Characteristics

Frequency
Voltage
Lamp Screw

Accessories

Emergency
Lamp

Lamp Type
Reference

Reference
Size
Number

Control

Power
Factor
Model

/
Lamp

Gear
Type

Unit
D W H

watt V / Hz mm mm mm

HME
Conventional
( high pressure
50 Control Gear
mercury )
( elliptic ) E27
HB100 70 constructed of 413 -- 665
HIE
80 - choke ballast
( metal halide ) - remote -
for
( elliptic ) ASL
100 (mercury
HPF Auxiliary 3/NM
vapor) 220 - 240V
HIT High Startup 50w 12v
1 125
( Metal halide ) Power Lamp GY6,35
50 / 60Hz
( tubular ) Factor ( max 230w ) 3 hours
150 - choke ballast
( B15d / E27 ) Non-
+
HSE Maintained
175 igniter
(high pressure sodium)
for
HB100G ( elliptic ) 420 -- 665
250 (metal halide)
&
HST E40
400 (sodium vapor)
(high pressure sodium)
( tubular )
Applications Suitable to be used in: Gyms, sport centers, commercial premises, warehouses and stores, etc…

Made of die-cast aluminum –appliance body- with cooling ¿ns on top-cover, Painted Grey
Housing
“Other color ¿nishes upon request”

Shaped reÀector in 99.8 s aluminum oxidized, anode process polished for high light output.
Tempered safety glass for high protection degree is available on request,
The glass is tenable to the reÀector with UV balanced silicon gasket
Light Controller
by means of stainless steel ring and ¿xing screw.
“ / CG “ Clear tempered glass
“ / FG “ Frosted tempered glass Photometrics & Dimensions
Mounting Surface / Pendant.

HB100 400W HIE


Control Gear High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.

220v - 240v, 50 / 60Hz.


Voltage / Frequency
“Other Voltages upon request”

Cable Entry 1x22 mm Ø hole on top.

125w, 175w, 250w , 400w High Pressure Mercury HME (MBF)

160w, 250w, 500w High Pressure Mercury HME (MBF)


Mercury-Tungsten blended self ballasted (no control gear required)
Lamps
150w, 175w, 250w, 400w Metal Halide HIE/HIT (Edison Base)
150w, 250w, 400w High Pressure Sodium HSE/HST (Edison Base)

“Other HID lamps upon request”

170
Ornamental Highbay Prismatic IP44
SERIES : HB100P

Technical Data
to order : follow the sequence mr - ln / ls - lt - lsr - v/h - pf – acc - emu

Physical Characteristics

Frequency
Voltage
Lamp Screw

Accessories

Emergency
Lamp

Lamp Type
Reference

Reference
Size
Number

Control

Power
Factor
Model

/
Lamp

Gear
Type

Unit
D W H

watt V / Hz mm mm mm

HME
Conventional
( high pressure
Control Gear
50 mercury )
( elliptic ) E27
constructed of
70
HIE
- choke ballast
80 ( metal halide )
for
( elliptic )
(mercury
100 HPF
vapor) 220 - 240V
HIT High
HB100P 1 -- -- 410 -- 675
125 ( Metal halide ) Power
50 / 60Hz
( tubular ) Factor
- choke ballast
150
+
HSE
igniter
175 (high pressure sodium)
for
( elliptic )
(metal halide)
250
&
HST E40
(sodium vapor)
(high pressure sodium)
( tubular )
Applications Suitable to be used in: Gyms, sport centers, commercial premises, warehouses and stores, etc…

Made of die-cast aluminum –appliance body- with cooling ¿ns on top-cover, Painted grey
Housing
“Other color ¿nishes upon request”

ReÀector is made of UV stabilized prismatic polycarbonate.


Light Controller
Protection prismatic polycarbonate cover available on request.

Mounting Surface / Pendant.


Photometrics & Dimensions
Control Gear High Power Factor “HPF” ( • 90 ) Control Gear.

HB100P 400W HIE


220v - 240v, 50 / 60Hz.
Voltage / Frequency
“Other Voltages upon request”

Cable Entry 1x22 mm Ø hole on top.

125w, 175w, 250w

160w, 250w
Mercury-Tungsten blended self ballasted (no control gear required)
Lamps
150w, 175w, 250w
150w, 250w

“Other HID lamps upon request”

172
Ornamental Lowbay Aluminium IP65
SERIES : LB100
IP20 W/O Cover

Technical Data
To order : follow the sequence mr - ln / ls - lt - lsr - v/h - pf – acc - emu
Physical

Frequency
Characteristics

Lamp Screw

Voltage

Accessories

Emergency
Lamp Type
Reference

Reference
Lamp
Size
Number

Control

Power
Factor
Model

Lamp

/
Gear
Type

Unit
D W H

watt V / Hz mm mm mm

EB
Electronic
CFL G24d-3 High
( compact Àuorescent ) Frequency
26D/T
HME G24q-3 EBD
HPF
32T ( high pressure Dimmable - remote -
High
mercury ) Electronic
Power
42T ( elliptic ) GX24q-3 High 3/NM
Factor
Frequency 3 hours
57T HIE Non-
( metal halide ) GX24q-4 Maintained
HF
70T ( elliptic ) 220 - 240V
High
LB100 1 Conventional -- 350 -- 480
Frequency
70 HIT GX24q-5 Control Gear 50 / 60Hz
( Metal halide ) constructed of: 3/M
80 ( tubular ) - choke ballast 3 hours
EBD
GX24q-6 for Maintained
Dimmable
100 HSE (mercury
Electronic
(high pressure sodium) vapor) - for CFL
High
125 ( elliptic ) E27 - choke ballast only -
Frequency
+
150 HST igniter
(high pressure sodium) E27 for
Applications Suitable to be used in: Gyms, sport centers, commercial premises, warehouses and stores, etc… ( tubular ) (metal halide)
&
(sodium vapor)

Made of die-cast aluminum –appliance body- with cooling ¿ns on top-cover, Painted grey
Housing
“Other color ¿nishes upon request”

Shaped reÀector in 99.8 s aluminum oxidized, anode process polished for high light output.
Tempered safety glass for high protection degree is available on request,
The glass is tenable to the reÀector with UV balanced silicon gasket
Light Controller
by means of stainless steel ring and ¿xing screw.
“ / CG “ Clear tempered glass
“ / FG “ Frosted tempered glass Photometrics & Dimensions
Mounting Surface / Pendant.

LB100 150W HIT


Control Gear High Power Factor “HPF” ( • 90 ) Control Gear .

220v - 240v, 50 / 60Hz.


Voltage / Frequency
“Other Voltages upon request”

Cable Entry 1x22 mm Ø hole on top.

26w TC-D – TC-DE, 32w, 42w TC-TE Compact Fluorescent


80w, 125w High Pressure Mercury HME (MBF)
Lamps
70w, 150w Metal Halide HIE/HIT (Edison Base)
50w, 70w, 150w Pressure Sodium HSE/HST (Edison Base)

174
Ornamental Lowbay Prismatic IP44
SERIES : LBP
IP20
Technical Data
To order : follow the sequence mr - ln / ls - lt - lsr - v/h - pf – acc - emu
Physical
Characteristics

Frequency
Voltage
Lamp Screw

Accessories

Emergency
Lamp

Lamp Type
Reference

Reference
Size
Number

Control

Power
Factor
Model

/
Lamp

Gear
Type

Unit
D W H

watt V / Hz mm mm mm

EB
Electronic
G24d-3 High
CFL
Frequency
( compact Àuorescent )
26D/T
G24q-3 EBD
HME
Dimmable HPF
32T ( high pressure - remote -
Electronic High
mercury )
GX24q-3 High Power
42T ( elliptic ) 3/NM
Frequency Factor
3 hours
57T HIE Non-
GX24q-4
( metal halide ) Maintained
HF
70T ( elliptic ) 220 - 240V
Conventional High
LBP 1 -- 320 -- 450
GX24q-5 Control Gear Frequency
70 HIT 50 / 60Hz
constructed of:
( Metal halide ) 3/M
- choke ballast
80 ( tubular ) 3 hours
GX24q-6 for EBD
Maintained
(mercury Dimmable
100 HSE
vapor) Electronic
(high pressure sodium) - for CFL
E27 - choke ballast High
125 ( elliptic ) only -
Applications Suitable to be used in: Gyms, sport centers, commercial premises, warehouses and stores, etc… + Frequency
igniter
150 HST
for
(high pressure sodium)
(metal halide)
( tubular )
Made of die-cast aluminum –appliance body- with cooling ¿ns on top-cover, Painted grey &
Housing (sodium vapor)
“Other color ¿nishes upon request”

ReÀector is made of UV stabilized prismatic polycarbonate.


Light Controller
Protection prismatic polycarbonate cover available on request.

Mounting Surface / Pendant.


Photometrics & Dimensions
Control Gear High Power Factor “HPF” ( • 90 ) Control Gear .

LBP 2/42W TC-TE


220v - 240v, 50 / 60Hz.
Voltage / Frequency
“Other Voltages upon request”

Cable Entry 1x22 mm Ø hole on top.

26w TC-D – TC-DE, 32w, 42w TC-TE Compact Fluorescent


80w, 125w High Pressure Mercury HME (MBF)
Lamps
70w, 150w Metal Halide HIE/HIT (Edison Base)
50w, 70w, 150w Pressure Sodium HSE/HST (Edison Base)

176
Hazard Location Luminaires
Moisture Proof

SQUARE LUMINAIRE SQUARE PRISMATIC WEATHERPROOF OPAL WEATHERPROOF


PRISMATIC

SQL 223-222 SQP 225-224 WPO 227-226 WPP 229-228

WEATHERPROOF MOISTUREPROOF
CIRCULAR LUMINAIRE FITTING (ACRYLIC + EXTRA PROTECTION
OPAL POLYESTER (PC+PC)

CLO 231-230 WPZM 233-232 WPLN 237-236


Square Luminaire IP65
SERIES : SQL

Technical Data
To Order : follow the sequence mr - ln / ls - cgt - v/h - pf - acc - emu

Physical Characteristics

Frequency
Voltage
Lamp
Size

Accessories

Emergency
Reference

Optional
Number

Control

Power
Factor
Model

Lamp

Gear
Type

Unit
L W H

watt V / Hz mm mm mm

1
11S
NS
Normal
18L Start
2
HPF
DEOS 300 300 83
High
16DD Electronic
Power
1 28DD Starter
220 - 240V Factor
38DD
EB
SQL 50 / 60Hz -- --
22LC Electronic
1 High
22FC Frequency
HF
High
EBD
Applications Suitable to be used in: corridors, circulation area & general indoor and outdoor application. Dimmable
Frequency
1
Electronic
High
9S Frequency 200 200 58
Housing Molded polycarbonate base suitable for energy savings compact lamps.
2

Molded opal polycarbonate, with self-tight locking between base and diffuser making it dust and water
Light Controller
protected type

Mounting Surface.
Photometrics & Dimensions
High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.
Control Gear High Frequency Electronic Control Gear “ECG”.
High Frequency Dimmable Electronic Control Gear “ECG”.
SQL 2/11W TC-S
220v - 240v, 50 / 60Hz.
Voltage / Frequency
“Other Voltages upon request”

Cable Entry 1x22 mm Ø hole on top.

9w, 11w TC-S Compact Fluorescent for Normal Start “NS”, Electronic Start “DEOS” or Electronic High
Frequency “HF” Ballast “EB”.

16w, 26w, 38w TC-DD Compact Fluorescent for Normal Start “NS”, Electronic Start “DEOS” or Electronic High
Lamps
Frequency “HF” Ballast “EB”.

22w T-R Circular Fluorescent for Normal Start “NS”, Electronic Start “DEOS” or Electronic High Frequency
“HF” Ballast “EB”

3 Hours duration -remote- Emergency Unit “EMU” with battery pack Maintained “/M” or Non-Maintained “/NM”
for one lamp, and for various lamp types and voltage networks combinations.
Emergency Unit
“Additional Emergency Units to operate more than one lamp on request”

182
Weatherproof Opal IP54
SERIES : WPO

Technical Data
To Order : follow the sequence mr - ln / ls - cgt - v/h - pf - acc - emu

Physical Characteristics

Frequency
Voltage
Lamp
Size

Accessories

Emergency
Reference

Optional
Number

Control

Power
Factor
Model

Lamp

Gear
Type

Unit
L W H

watt V / Hz mm mm mm

1 665 103 116

14 NS
2 Normal NM/3 640 640 110
17 Start hours 3
FTB
18 Non-
3 HPF Fused 640 640 110
DEOS Maintained
24 High Terminal
Electronic
Power Block
Starter
4 Factor 640 640 110
TRW
EB 220 - 240V
WPO Temperature
28 Electronic 50 / 60Hz
1 Resistant 1260 103 116
High
32 Wire
Frequency
36 HF
2 High AR 1260 190 98
Applications Suitable to be used in: corridors, circulation area & general indoor and outdoor application. 54 EBD
Frequency Aluminum
Dimmable M/3
ReÀector
35 Electronic hours 3
1 High Maintained 1560 103 116
49
Housing Base-plate is made of grey ¿berglass reinforced polyester Frequency
58
2 1560 190 98
80

One piece injected methacrylate opal diffuser, providing good light distribution and ensures uniformity of
Light Controller luminance and good ceiling lighting. Special UV resistant is gasket made of durable high density polyurethane
Poured on the base-plate seal with locking latches, ensures tight ¿t between the body and diffuser

Mounting Surface.
Photometrics & Dimensions
High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.
Control Gear High Frequency Electronic Control Gear “ECG”.
High Frequency Dimmable Electronic Control Gear “ECG”.
WPO 2/36W
220v - 240v, 50 / 60Hz.
Voltage / Frequency
“Other Voltages upon request”

Cable Entry 1x22 mm Ø hole on top.

18, 36 & 58 watt T8/T26 Fluorescent for Normal Start “NS”, Electronic Start “DEOS” or Electronic High
Frequency “HF” Ballast “EB”.
17& 32 watt T8 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
Lamps 14, 28 & 35 watt FH T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
24, 49, 54 & 80 watt FQ T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
“Other lamps (T5/T16 – T8/T26 – T12/T38 – TC-L) upon request & ¿tting housing dimensions subject to
changes accordingly”

3 Hours duration -remote- Emergency Unit “EMU” with battery pack Maintained “/M” or Non-Maintained “/NM”
for one lamp, and for various lamp types and voltage networks combinations.
Emergency Unit
“Additional Emergency Units to operate more than one lamp on request”

184
Weatherproof Prismatic IP54
SERIES : WPP

Technical Data
To Order : follow the sequence mr - ln / ls - cgt - v/h - pf - acc - emu

Physical Characteristics

Frequency
Voltage
Lamp
Size

Accessories

Emergency
Reference

Optional
Number

Control

Power
Factor
Model

Lamp

Gear
Type

Unit
L W H

watt V / Hz mm mm mm

1 665 103 116

14 NS
2 Normal 3/NM 640 640 110
17
Start 3 hours
18 FTB
Non-
3 HPF Fused 640 640 110
24 DEOS Maintained
High Terminal
Electronic
Power Block
Starter
4 Factor 640 640 110
TRW
EB 220 - 240V
WPP Temperature
28 Electronic 50 / 60Hz
1 Resistant 1260 103 116
High
32 Wire
Frequency
36 HF
Applications Suitable to be used in: corridors, circulation area & general indoor and outdoor application. 2 High AR 1260 190 98
54 EBD
Frequency Aluminum
Dimmable 3/M
ReÀector
35 Electronic 3 hours
1 High Maintained 1560 103 116
Housing Base-plate is made of grey ¿berglass reinforced polyester 49 Frequency
58
2 1560 190 98
One piece injected methacrylate prismatic diffuser, providing good light distribution and ensuring a partial 80
upward light intensity towards the ceiling, thus avoiding unpleasant glare characterizes the diffuser. Special
Light Controller UV resistant is gasket made of durable high density polyurethane Poured on the base-plate seal with locking
latches, ensures tight ¿t between
the body and diffuser

Mounting Surface. Photometrics & Dimensions


High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.
Control Gear High Frequency Electronic Control Gear “ECG”.
High Frequency Dimmable Electronic Control Gear “ECG”. WPP 2/36W
220v - 240v, 50 / 60Hz.
Voltage / Frequency
“Other Voltages upon request”

Cable Entry 1x22 mm Ø hole on top.

18, 36 & 58 watt T8/T26 Fluorescent for Normal Start “NS”, Electronic Start “DEOS” or Electronic High
Frequency “HF” Ballast “EB”.
17& 32 watt T8 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
Lamps 14, 28 & 35 watt FH T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
24, 49, 54 & 80 watt FQ T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
“Other lamps (T5/T16 – T8/T26 – T12/T38 – TC-L) upon request & ¿tting housing dimensions subject to
changes accordingly”
3 Hours duration -remote- Emergency Unit “EMU” with battery pack Maintained “/M” or Non-Maintained “/NM”
for one lamp, and for various lamp types and voltage networks combinations.
Emergency Unit
“Additional Emergency Units to operate more than one lamp on request”

186
Circular Luminaire Opal IP65
SERIES : CLO

Technical Data
To Order : follow the sequence mr - ln / ls - cgt - v/h - pf - acc - emu

Physical Characteristics

Frequency
Voltage
Lamp
Size

Accessories

Emergency
Reference

Optional
Number

Control

Power
Factor
Model

Lamp

Gear
Type

Unit
L W H

watt V / Hz mm mm mm

1 11S
NS
2 18L
Normal
Start
16DD HPF
DEOS
High
Electronic
1 28DD Power
Starter
Factor
38DD
EB 220 - 240V
CLO -- -- 380 -- 83
Electronic 50 / 60Hz
High
22LC
Frequency
HF
Applications Suitable to be used in: corridors, circulation area & general indoor and outdoor application. 22FC High
EBD
Frequency
Dimmable
1 32LC
Electronic
High
40FC
Housing Molded polycarbonate base suitable for energy savings compact lamps. Frequency
55FC

Molded opal polycarbonate, with self-tight locking between base and diffuser making it dust and water
Light Controller
protected type

Mounting Surface.
Photometrics & Dimensions
High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.
Control Gear High Frequency Electronic Control Gear “ECG”.
High Frequency Dimmable Electronic Control Gear “ECG”.
CLO 2/18W TC-L
220v - 240v, 50 / 60Hz.
Voltage / Frequency
“Other Voltages upon request”

Cable Entry 1x22 mm Ø hole on top.

9w, 11w TC-S Compact Fluorescent for Normal Start “NS”, Electronic Start “DEOS” or Electronic High
Frequency “HF” Ballast “EB”.

16w, 26w, 38w TC-DD Compact Fluorescent for Normal Start “NS”, Electronic Start “DEOS” or Electronic High
Lamps
Frequency “HF” Ballast “EB”.

22w T-R Circular Fluorescent for Normal Start “NS”, Electronic Start “DEOS” or Electronic High Frequency
“HF” Ballast “EB”

3 Hours duration -remote- Emergency Unit “EMU” with battery pack Maintained “/M” or Non-Maintained “/NM”
for one lamp, and for various lamp types and voltage networks combinations.
Emergency Unit
“Additional Emergency Units to operate more than one lamp on request”

188
Weatherproof Fitting (Acrylic+Polyester) IP65
SERIES : WPZM

Technical Data
To Order : follow the sequence mr - ln / ls - cgt - v/h - pf - acc - emu

Physical Characteristics

Frequency
Voltage
Lamp
Size

Accessories

Emergency
/
Reference

Optional
Number

Control

Power
Factor
Model

Lamp

Gear
Type

Unit
L W H

watt V / Hz mm mm mm

1 14 NS 680 112 120


17 Normal 3/NM
18 Start FTB 3 hours
2 Fused Non- 680 182 120
24 HPF
DEOS Terminal Maintained
High
Electronic Block
Power
Starter
1 28 Factor 1280 112 120
TRW
32 220 - 240V
EB Temperature
WPZM
36 Electronic Resistant
50 / 60Hz
2 High Wire 1280 182 120
54 Frequency
HF
TW
Applications Suitable to be used in: stores and cold stores rooms, warehouses, parking area and general outdoor application….
EBD
High
Through
1 35 Frequency 1580 112 120
Dimmable Wire 3/M
49 Electronic 3 hours
58 High Maintained
Housing Base-plate is made of self extinguishing grey ¿berglass reinforced polyester 2
80
Frequency 1580 182 120

Clear acrylic injected UV stable diffuser, ReÀector of steel plating, degreased and treated and coated with powder
Light Controller epoxy-polyester heat-hardened, stable against UV radiation. Diffuser is tightened to the body by mean of
expandable polyurethane seal and closing (polycarbonate or stainless steel) clips to ensure perfect tightness.

Mounting Surface.
Photometrics & Dimensions
High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.
High Power Factor “HPF” ( • 90 ) Pre-Heat Rapid Start “RS”.
Control Gear High Frequency Electronic Control Gear “ECG”.
High Frequency Dimmable Electronic Control Gear “ECG”.
WPZM 2/36w
220v - 240v, 50 / 60Hz.
Voltage / Frequency
“Other Voltages upon request”

Cable Entry 1x22 mm Ø hole on top.

18, 36 & 58 watt T8/T26 Fluorescent for Normal Start “NS”, Electronic Start “DEOS” or Electronic High Frequency
“HF” Ballast “EB”.
17& 32 watt T8 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
Lamps 14, 28 & 35 watt FH T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
24, 49, 54 & 80 watt FQ T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
“Other lamps (T5/T16 – T8/T26 – T12/T38 – TC-L) upon request & ¿tting housing dimensions subject to changes
accordingly”

3 Hours duration -remote- Emergency Unit “EMU” with battery pack Maintained “/M” or Non-Maintained “/NM” for
one lamp, and for various lamp types and voltage networks combinations.
Emergency Unit
“Additional Emergency Units to operate more than one lamp on request”

190
Moistureproof Extra Protection (PC+PC) IP65
SERIES : WPLV

Technical Data
To Order : follow the sequence mr - ln / ls - cgt - v/h - pf - acc - emu

Physical Characteristics

Frequency
Voltage
Lamp
Size

Accessories

Emergency
/
Reference

Optional
Number

Control

Power
Factor
Model

Lamp

Gear
Type

Unit
L W H

watt V / Hz mm mm mm

1 14 660 86 90
NS
17 Normal 3/NM
18 Start FTB 3 hours
2 24 Fused Non- 660 136 90
HPF
DEOS Terminal Maintained
High
Electronic Block
Power
28 Starter
1 Factor 1270 86 90
TRW
32 220 - 240V
EB Temperature
WPLV
36 Electronic Resistant
Suitable to be used in: stores and cold stores rooms, warehouses, parking area and general outdoor 50 / 60Hz
Applications 2 High Wire 1270 136 90
application…. 54
Frequency
HF
TW
High
EBD Through
1 35 Frequency 1570 86 90
Dimmable Wire 3/M
Housing Made of grey impact resistant polycarbonate body 49 Electronic 3 hours
58 High Maintained
2 Frequency 1570 136 90
80
Clear polycarbonate injected UV stable diffuser, ReÀector of steel plating, degreased and treated and coated with
powder epoxy-polyester heat-hardened, stable against UV radiation. To narrow the luminous Àux down it is possible to
Light Controller use specular aluminum reÀector placed under the lamps.
Diffuser is tightened to the body by mean of expandable polyurethane seal and closing (polycarbonate or
stainless steel) clips to ensure perfect tightness.

Mounting Surface. Photometrics & Dimensions


High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.
Control Gear High Frequency Electronic Control Gear “ECG”.
High Frequency Dimmable Electronic Control Gear “ECG”. WPLC 2/36w

220v - 240v, 50 / 60Hz.


Voltage / Frequency
“Other Voltages upon request”

1x22 mm Ø hole on top.


Cable Entry
2x22 mm Ø knock-out holes at each side for continuous row.

18, 36 & 58 watt T8/T26 Fluorescent for Normal Start “NS”, Electronic Start “DEOS” or Electronic High
Frequency “HF” Ballast “EB”.
17& 32 watt T8 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
Lamps 14, 28 & 35 watt FH T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
24, 49, 54 & 80 watt FQ T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
“Other lamps (T5/T16 – T8/T26 – T12/T38 – TC-L) upon request & ¿tting housing dimensions subject to
changes accordingly”

3 Hours duration -remote- Emergency Unit “EMU” with battery pack Maintained “/M” or Non-Maintained “/NM”
for one lamp, and for various lamp types and voltage networks combinations.
Emergency Unit
“Additional Emergency Units to operate more than one lamp on request”

192
Emergency - Exit Signs
Ceiling / Wall

EMERGENCY SURFACE EMERGENCY EMERGENCY SURFACE EMERGENCY RECESSED


- DOUBLE SIDE RECESSED SINGLE - DOUBLE SIDE SINGLE - DOUBLE SIDE

VX - VXD 198-199 VXR 200-201 VXP - VXPD 202-203 VXPR - VXPDR 204-205

EMERGENCY SINGLE EMERGENCY SINGLE EMERGENCY SURFACE EMERGENCY RECESSED


- DOUBLE SIDE - DOUBLE SIDE SINGLE - DOUBLE SIDE SINGLE - DOUBLE SIDE

SE - SED 206-207 NEU - NEUD 208-209 NEUP - NEUPD 210-211 NEUPR - NEUPDR 212-213
Emergency Surface Single - Double Side IP40
SERIES : VX - VXD

Technical Data
To Order : follow the sequence mr – ln ls / d – et – v/h

Physical Characteristics

Frequency
Duration

Voltage
Emergency
Lamp
Reference

Size
Number
Model

/
Lamp

Type
L1 W H

watt hour V / Hz mm mm mm

6 290 130 83

8 365 130 83

VX Mains

6 290 130 83

2
1
Non-Maintained
8 365 130 83
220 - 240V

50 / 60Hz
6 290 130 170
Maintained
3
1

8 365 130 170

VXD Sustained
Suitable to be used in: of¿ces, premises, rooms-doorways, corridors & passages and other alike directional
Applications
use. 6 290 130 170

Made of press welded Cold Rolled Steel “CRS” sheet of tight construction to prevent light leakage, all metal 2
parts pre-treated with a full degreasing and phosphate process, painted in stove enameled white baked epoxy
Housing polyester mix-powder to ensure high reÀectance of painted surfaces. “Other color ¿nishes upon request” 8 365 130 170
The unit can be supplied in single sided, double sided and recessed versions. The double sided version has
an increase height.

Light Controller Opal polycarbonate diffuser.

Mounting Surface or suspended .

High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.


Photometrics & Dimensions
Control Gear
High Frequency Electronic Control Gear “ECG”.

220v - 240v, 50 / 60Hz.


Voltage / Frequency
“Other Voltages upon request”

Cable Entry 1x22 mm Ø hole on top. “Extra knock-out holes upon request”

Lamps 6 & 8 watt T5/T16 Fluorescent for Normal Start “NS” or Electronic High Frequency “HF” Ballast “EB”.

Various legends and pictographs can be supplied upon request.


- White color for pictographs with directional arrows and text (Arabic & English) on green or red background
Legend Kits
according to international NORMS (NFPA, BSC, ….)
- Green or red text color in Arabic and English with directional arrows on white background.
Excluding slave version, all ¿xtures are supplied with emergency converter unit, maintenance-free sealed
battery, fully automatic constant current charging system, charge monitoring LED and system-test reset
switch. Types of emergency systems :
- Non-maintained, where emergency lighting is systems in W/C emergency lamp (lamps) are in operation only
when the normal lighting or main AC power fails.
Emergency Unit
- Maintained, where emergency lighting is systems in W/C emergency lamp (lamps) are in operation at all
times, lamp (lamps) operated from AC mains and from the battery on mains failure.
- Sustained, where emergency lighting luminaire contains two or more lamps, one of which is energized from
the AC mains supply and the others from the battery on mains failure.
Emergency operation is for 3 hours duration.

198
Emergency Recessed IP40
SERIES : VXR

Technical Data
To Order : follow the sequence mr – ln ls / d – et – v/h

Physical Characteristics

Frequency
Duration

Voltage
Emergency
Lamp
Reference

Size
Number
Model

/
Lamp

Type
L1 W H

watt hour V / Hz mm mm mm

Mains

1 6 1
Non-Maintained
220 - 240V
VXR 432 190 85
50 / 60Hz
Maintained
2 8 3

Suitable to be used in: of¿ces, premises, rooms-doorways, corridors & passages and other alike directional Sustained
Applications
use.
Made of press welded Cold Rolled Steel “CRS” sheet of tight construction to prevent light leakage, all metal
parts pre-treated with a full degreasing and phosphate process, painted in stove enameled white baked epoxy
Housing polyester mix-powder to ensure high reÀectance of painted surfaces. “Other color ¿nishes upon request”
The unit can be supplied in single sided, double sided and recessed versions. The double sided version has
an increase height.

Light Controller Opal polycarbonate diffuser.

Mounting Recessed.

High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.


Photometrics & Dimensions
Control Gear
High Frequency Electronic Control Gear “ECG”.

220v - 240v, 50 / 60Hz.


Voltage / Frequency
“Other Voltages upon request”

Cable Entry 1x22 mm Ø hole on top. “Extra knock-out holes upon request”

Lamps 6 & 8 watt T5/T16 Fluorescent for Normal Start “NS” or Electronic High Frequency “HF” Ballast “EB”.

Various legends and pictographs can be supplied upon request.


- White color for pictographs with directional arrows and text (Arabic & English) on green or red background
Legend Kits
according to international NORMS (NFPA, BSC, ….)
- Green or red text color in Arabic and English with directional arrows on white background.
Excluding slave version, all ¿xtures are supplied with emergency converter unit, maintenance-free sealed
battery, fully automatic constant current charging system, charge monitoring LED and system-test reset
switch. Types of emergency systems :
- Non-maintained, where emergency lighting is systems in W/C emergency lamp (lamps) are in operation only
when the normal lighting or main AC power fails.
Emergency Unit
- Maintained, where emergency lighting is systems in W/C emergency lamp (lamps) are in operation at all
times, lamp (lamps) operated from AC mains and from the battery on mains failure.
- Sustained, where emergency lighting luminaire contains two or more lamps, one of which is energized from
the AC mains supply and the others from the battery on mains failure.
Emergency operation is for 3 hours duration.

200
Emergency Surface Single - Double Side IP40
SERIES : VXP - VXPD

Technical Data
To Order : follow the sequence mr – ln ls / d – et – v/h

Physical Characteristics

Frequency
Duration

Voltage
Emergency
Lamp
Reference

Size
Number
Model

/
Lamp

Type
L1 L2 W H X Y

watt hour V / Hz mm mm mm mm mm mm

VXP

Mains

220 - 240V
Non-Maintained
1 8 380 350 80 80 200 100
50 / 60Hz

3
Maintained

Suitable to be used in: of¿ces, premises, rooms-doorways, corridors & passages and other alike directional VXPD
Applications
use.
Made of press welded Cold Rolled Steel “CRS” sheet of tight construction to prevent light leakage, all metal
parts pre-treated with a full degreasing and phosphate process, painted in stove enameled white baked epoxy
Housing polyester mix-powder to ensure high reÀectance of painted surfaces. “Other color ¿nishes upon request”
The unit can be supplied in single sided, double sided and recessed versions. The double sided version has
an increase height.

Light Controller Polycarbonate diffuser.

Mounting Surface or suspended.

High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.


Photometrics & Dimensions
Control Gear
High Frequency Electronic Control Gear “ECG”.

220v - 240v, 50 / 60Hz.


Voltage / Frequency
“Other Voltages upon request”

Cable Entry 1x22 mm Ø hole on top. “Extra knock-out holes upon request”

Lamps 8 watt T5/T16 Fluorescent for Normal Start “NS” or Electronic High Frequency “HF” Ballast “EB”.

Various legends and pictographs can be supplied upon request.


- White color for pictographs with directional arrows and text (Arabic & English) on green or red background
Legend Kits
according to international NORMS (NFPA, BSC, ….)
- Green or red text color in Arabic and English with directional arrows on white background.
Excluding slave version, all ¿xtures are supplied with emergency converter unit, maintenance-free sealed
battery, fully automatic constant current charging system, charge monitoring LED and system-test reset
switch. Types of emergency systems :
- Non-maintained, where emergency lighting is systems in W/C emergency lamp (lamps) are in operation only
when the normal lighting or main AC power fails.
Emergency Unit
- Maintained, where emergency lighting is systems in W/C emergency lamp (lamps) are in operation at all
times, lamp (lamps) operated from AC mains and from the battery on mains failure.
- Sustained, where emergency lighting luminaire contains two or more lamps, one of which is energized from
the AC mains supply and the others from the battery on mains failure.
Emergency operation is for 3 hours duration.

202
Emergency Recessed Single - Double Side IP40
SERIES : VXPR - VXPDR

Technical Data
To Order : follow the sequence mr – ln ls / d – et – v/h

Physical Characteristics

Frequency
Duration

Voltage
Emergency
Lamp
Reference

Size
Number
Model

/
Lamp

Type
L1 L2 W H X Y

watt hour V / Hz mm mm mm mm mm mm

VXPR

Mains

220 - 240V
Non-Maintained
1 8 405 350 80 80 200 150
50 / 60Hz

3
Maintained

Suitable to be used in: of¿ces, premises, rooms-doorways, corridors & passages and other alike directional VXPRD
Applications
use.
Made of press welded Cold Rolled Steel “CRS” sheet of tight construction to prevent light leakage, all metal
parts pre-treated with a full degreasing and phosphate process, painted in stove enameled white baked epoxy
Housing polyester mix-powder to ensure high reÀectance of painted surfaces. “Other color ¿nishes upon request”
The unit can be supplied in single sided, double sided and recessed versions. The double sided version has
an increase height.

Light Controller Opal or clear polycarbonate diffuser.

Mounting Ceiling Recessed.

High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.


Photometrics & Dimensions
Control Gear
High Frequency Electronic Control Gear “ECG”.

220v - 240v, 50 / 60Hz.


Voltage / Frequency
“Other Voltages upon request”

Cable Entry 1x22 mm Ø hole on top. “Extra knock-out holes upon request”

Lamps 8 watt T5/T16 Fluorescent for Normal Start “NS” or Electronic High Frequency “HF” Ballast “EB”.

Various legends and pictographs can be supplied upon request.


- White color for pictographs with directional arrows and text (Arabic & English) on green or red background
Legend Kits
according to international NORMS (NFPA, BSC, ….)
- Green or red text color in Arabic and English with directional arrows on white background.
Excluding slave version, all ¿xtures are supplied with emergency converter unit, maintenance-free sealed
battery, fully automatic constant current charging system, charge monitoring LED and system-test reset
switch. Types of emergency systems :
- Non-maintained, where emergency lighting is systems in W/C emergency lamp (lamps) are in operation only
when the normal lighting or main AC power fails.
Emergency Unit
- Maintained, where emergency lighting is systems in W/C emergency lamp (lamps) are in operation at all
times, lamp (lamps) operated from AC mains and from the battery on mains failure.
- Sustained, where emergency lighting luminaire contains two or more lamps, one of which is energized from
the AC mains supply and the others from the battery on mains failure.
Emergency operation is for 3 hours duration.

204
Emergency Single - Double Side IP40
SERIES : SE - SED

Technical Data
To Order : follow the sequence mr – ln ls / d – et – v/h

Physical Characteristics

Frequency
Duration

Voltage
Emergency
Lamp
Reference

Size
Number
Model

/
Lamp

Type
L1 D1 D2 W H

watt hour V / Hz mm mm mm mm mm

SE Mains 490 -- -- 244 65

1 1
Non-Maintained
220 - 240V
8
50 / 60Hz
Maintained
2 3

Suitable to be used in: of¿ces, premises, rooms-doorways, corridors & passages and other alike directional SED Sustained 490 105 75 244 --
Applications
use.
Made of press welded Cold Rolled Steel “CRS” sheet of tight construction to prevent light leakage, all metal
parts pre-treated with a full degreasing and phosphate process, painted in stove enameled white baked epoxy
Housing polyester mix-powder to ensure high reÀectance of painted surfaces. “Other color ¿nishes upon request”
The unit can be supplied in single sided, double sided and recessed versions. The double sided version has
an increase height.

Light Controller Opal polycarbonate diffuser.

Mounting Surface or suspended .

High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.


Photometrics & Dimensions
Control Gear
High Frequency Electronic Control Gear “ECG”.

220v - 240v, 50 / 60Hz.


Voltage / Frequency
“Other Voltages upon request”

Cable Entry 1x22 mm Ø hole on top. “Extra knock-out holes upon request”

Lamps 8 watt T5/T16 Fluorescent for Normal Start “NS” or Electronic High Frequency “HF” Ballast “EB”.

Various legends and pictographs can be supplied upon request.


- White color for pictographs with directional arrows and text (Arabic & English) on green or red background
Legend Kits
according to international NORMS (NFPA, BSC, ….)
- Green or red text color in Arabic and English with directional arrows on white background.
Excluding slave version, all ¿xtures are supplied with emergency converter unit, maintenance-free sealed
battery, fully automatic constant current charging system, charge monitoring LED and system-test reset
switch. Types of emergency systems :
- Non-maintained, where emergency lighting is systems in W/C emergency lamp (lamps) are in operation only
when the normal lighting or main AC power fails.
Emergency Unit
- Maintained, where emergency lighting is systems in W/C emergency lamp (lamps) are in operation at all
times, lamp (lamps) operated from AC mains and from the battery on mains failure.
- Sustained, where emergency lighting luminaire contains two or more lamps, one of which is energized from
the AC mains supply and the others from the battery on mains failure.
Emergency operation is for 3 hours duration.

206
Emergency Single - Double Side IP40
SERIES : NEU - NEUD

Technical Data
To Order : follow the sequence mr – ln ls / d – et – v/h

Physical Characteristics

Frequency
Duration

Voltage
Emergency
Lamp
Reference

Size
Number
Model

/
Lamp

Type
L W H

watt hour V / Hz mm mm mm

NEU Mains 642 112 212

1 1
Non-Maintained
220 - 240V
18
50 / 60Hz
Maintained
2 3

Suitable to be used in: of¿ces, premises, rooms-doorways, corridors & passages and other alike directional
Applications NEUD Sustained 642 212 212
use.
Made of press welded Cold Rolled Steel “CRS” sheet of tight construction to prevent light leakage, all metal
parts pre-treated with a full degreasing and phosphate process, painted in stove enameled white baked epoxy
Housing polyester mix-powder to ensure high reÀectance of painted surfaces. “Other color ¿nishes upon request”
The unit can be supplied in single sided, double sided and recessed versions. The double sided version has
an increase height.

Light Controller Opal polycarbonate diffuser.

Mounting Surface or suspended .

Control Gear
High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”. Photometrics & Dimensions
High Frequency Electronic Control Gear “ECG”.

220v - 240v, 50 / 60Hz.


Voltage / Frequency
“Other Voltages upon request”

Cable Entry 1x22 mm Ø hole on top. “Extra knock-out holes upon request”

Lamps 18 watt T8/T26 Fluorescent for Normal Start “NS” or Electronic High Frequency “HF” Ballast “EB”.

Various legends and pictographs can be supplied upon request.


- White color for pictographs with directional arrows and text (Arabic & English) on green or red background
Legend Kits
according to international NORMS (NFPA, BSC, ….)
- Green or red text color in Arabic and English with directional arrows on white background.
Excluding slave version, all ¿xtures are supplied with emergency converter unit, maintenance-free sealed NEUD
battery, fully automatic constant current charging system, charge monitoring LED and system-test reset
switch. Types of emergency systems :
- Non-maintained, where emergency lighting is systems in W/C emergency lamp (lamps) are in operation only
when the normal lighting or main AC power fails.
Emergency Unit
- Maintained, where emergency lighting is systems in W/C emergency lamp (lamps) are in operation at all
times, lamp (lamps) operated from AC mains and from the battery on mains failure.
- Sustained, where emergency lighting luminaire contains two or more lamps, one of which is energized from
the AC mains supply and the others from the battery on mains failure. Emergency operation is for 3 hours
duration.

208 NEU
Emergency Surface Single - Double Side IP40
SERIES : NEUP - NEUPD

Technical Data
To Order : follow the sequence mr – ln ls / d – et – v/h

Physical Characteristics

Frequency
Duration

Voltage
Emergency
Lamp
Reference

Size
Number
Model

/
Lamp

Type
L1 L2 W H X Y

watt hour V / Hz mm mm mm mm mm mm

NEUP

Mains

220 - 240V
Non-
1 18 656 625 65 160 200 100
Maintained
50 / 60Hz

Maintained
Suitable to be used in: of¿ces, premises, rooms-doorways, corridors & passages and other alike directional
Applications NEUPD
use.
Made of press welded Cold Rolled Steel “CRS” sheet of tight construction to prevent light leakage, all metal
parts pre-treated with a full degreasing and phosphate process, painted in stove enameled white baked epoxy
Housing polyester mix-powder to ensure high reÀectance of painted surfaces. “Other color ¿nishes upon request”
The unit can be supplied in single sided, double sided and recessed versions. The double sided version has
an increase height.
Opal or clear polycarbonate diffuser.
Light Controller

Mounting Surface or suspended .

Control Gear
High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”. Photometrics & Dimensions
High Frequency Electronic Control Gear “ECG”.

220v - 240v, 50 / 60Hz.


Voltage / Frequency
“Other Voltages upon request”

Cable Entry 1x22 mm Ø hole on top. “Extra knock-out holes upon request”

Lamps 18 watt T8/T26 Fluorescent for Normal Start “NS” or Electronic High Frequency “HF” Ballast “EB”.

Various legends and pictographs can be supplied upon request.


- White color for pictographs with directional arrows and text (Arabic & English) on green or red background
Legend Kits
according to international NORMS (NFPA, BSC, ….)
- Green or red text color in Arabic and English with directional arrows on white background.
Excluding slave version, all ¿xtures are supplied with emergency converter unit, maintenance-free sealed
battery, fully automatic constant current charging system, charge monitoring LED and system-test reset
switch. Types of emergency systems :
- Non-maintained, where emergency lighting is systems in W/C emergency lamp (lamps) are in operation only
when the normal lighting or main AC power fails.
Emergency Unit
- Maintained, where emergency lighting is systems in W/C emergency lamp (lamps) are in operation at all
times, lamp (lamps) operated from AC mains and from the battery on mains failure.
- Sustained, where emergency lighting luminaire contains two or more lamps, one of which is energized from
the AC mains supply and the others from the battery on mains failure. Emergency operation is for 3 hours
duration.

210
Emergency Recessed Single - Double Side IP40
SERIES : NEUPR - NEUPRD

Technical Data
To Order : follow the sequence mr – ln ls / d – et – v/h

Physical Characteristics

Frequency
Duration

Voltage
Emergency
Lamp
Reference

Size
Number
Model

/
Lamp

Type
L1 L2 W H X Y

watt hour V / Hz mm mm mm mm mm mm

NEUPR

Mains

220 - 240V
1 18 Non-Maintained 640 600 110 113 200 100
50 / 60Hz

Maintained

Suitable to be used in: of¿ces, premises, rooms-doorways, corridors & passages and other alike directional NEUPRD
Applications
use.
Made of press welded Cold Rolled Steel “CRS” sheet of tight construction to prevent light leakage, all metal
parts pre-treated with a full degreasing and phosphate process, painted in stove enameled white baked epoxy
Housing polyester mix-powder to ensure high reÀectance of painted surfaces. “Other color ¿nishes upon request”
The unit can be supplied in single sided, double sided and recessed versions. The double sided version has
an increase height.

Light Controller Opal or clear polycarbonate diffuser.

Mounting Recessed

High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.


Photometrics & Dimensions
Control Gear
High Frequency Electronic Control Gear “ECG”.

220v - 240v, 50 / 60Hz.


Voltage / Frequency
“Other Voltages upon request”

Cable Entry 1x22 mm Ø hole on top. “Extra knock-out holes upon request”

Lamps 18 watt T8/T26 Fluorescent for Normal Start “NS” or Electronic High Frequency “HF” Ballast “EB”.

Various legends and pictographs can be supplied upon request.


- White color for pictographs with directional arrows and text (Arabic & English) on green or red background
Legend Kits
according to international NORMS (NFPA, BSC, ….)
- Green or red text color in Arabic and English with directional arrows on white background.
Excluding slave version, all ¿xtures are supplied with emergency converter unit, maintenance-free sealed
battery, fully automatic constant current charging system, charge monitoring LED and system-test reset
switch. Types of emergency systems :
- Non-maintained, where emergency lighting is systems in W/C emergency lamp (lamps) are in operation only
when the normal lighting or main AC power fails.
Emergency Unit
- Maintained, where emergency lighting is systems in W/C emergency lamp (lamps) are in operation at all
times, lamp (lamps) operated from AC mains and from the battery on mains failure.
- Sustained, where emergency lighting luminaire contains two or more lamps, one of which is energized from
the AC mains supply and the others from the battery on mains failure. Emergency operation is for 3 hours
duration.

212
Bed Head Unit
Wall Mounted

BEDHEAD UNIT

BHU200 218-219
Bedhead Unit IP20
SERIES : BHU200

Technical Data
To Order : follow the sequence mr - ln / ls + ln / ls - cgt - v/h - pf - acc - emu

Physical Characteristics

Frequency
Voltage

Accessories

Emergency
Lamp
Reference

Size
Number

Control

Power
Factor
Model

/
Lamp

Gear
Type

Unit
L W H

watt V / Hz mm mm mm

14

17
3/NM
18L FTB
1 NS LPF 3 hours
Fused
Normal Low Non-
18 Terminal
Start Power Factor Maintained
Block
24L
DEOS
TRW
Electronic
24 Temperature
Starter
Resistant
HPF
28 220 - 240V Wire
EB High 3/M
BHU200 1300 260 160
Electronic Power 3 hours
32 50 / 60Hz
High Factor Maintained
------
Frequency
36
Switches
EBD
36L Receptacles
Dimmable ------
Nurse Call
Applications Suitable to be used in: patient’s rooms and wards, clinics, emergency rooms, ICU. Electronic HF
40L Accessories
2 High High
Upon request
Frequency Frequency Upon request
54
Made of high quality extruded aluminum, painted in stove enameled white baked epoxy polyester mix-powder.
Housing
“Other color ¿nishes upon request” 55L

Light Controller Opal or prismatic metacrylate diffuser. 80L

Mounting Surface wall-mounted.

High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.


Control Gear
High Frequency Electronic Control Gear “ECG”.
Photometrics & Dimensions
220v - 240v, 50 / 60Hz.
Voltage / Frequency
“Other Voltages upon request”

1x22 mm Ø hole on back-side.


Cable Entry
“Extra knock-out holes upon request”

Lamps 18 watt T8/T26 Fluorescent for Normal Start “NS” or Electronic High Frequency “HF” Ballast “EB”.

18 & 36 watt T8/T26 Fluorescent for Normal Start “NS”, Electronic Start “DEOS” or Electronic High Frequency
“HF” Ballast “EB”.
20 & 40 watt T12/T38 Fluorescent for Rapid Start “RS”.
17 & 32 watt T8 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
Legend Kits
14 & 28 watt FH T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
24 & 49 watt FQ T5/T16 Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
18, 24, 36, 40, 55 & 80 watt TC-L Compact Fluorescent for Normal Start “NS”, or Electronic High Frequency
“HF” Ballast “EB”.

“Various types and models for medical accessories can be provided upon request through third party (i.e. gas
Emergency Unit
outlets, nurse call switch, receptacle & switches, ..)”

218
BHU100
Downlight
Recessed Spotlight Surface Downlight

FIXED RECESSED ADJUSTABLE DEEP RECESSED SURFACE DEEP SURFACE SHALLOW SURFACE CYLINDRICAL SURFACE SQUARE
SPOTLIGHT RECESSED SPOTLIGHT SPOTLIGHT REFLECTOR DOWNLIGHT REFLECTOR DOWNLIGHT DOWNLIGHT DOWNLIGHT

AR4100 224-225 AR4102 226-227 AR4106 228-229 S100 254-255 SS100 256-257 301 258-259 501 260-261

Recessed Downlight
Surface Wall Up-Downlight
RECESSED DEEP RECESSED SHALLOW RECESSED SHALLOW RECESSED SHALLOW
REFLECTOR DOWNLIGHT REFLECTOR DOWNLIGHT REFLECTOR DOWNLIGHT REFLECTOR DOWNLIGHT
SURFACE CYLINDRICAL SURFACE CYLINDRICAL
DOWNLIGHT UP-DOWNLIGHT

DL100 230-231 DL110 232-233 DL200 234-235 DL201 236-237

303 262-263 304 264-265


RECESSED SHALLOW RECESSED SHALLOW RECESSED SHALLOW RECESSED SHALLOW
REFLECTOR DOWNLIGHT REFLECTOR DOWNLIGHT REFLECTOR DOWNLIGHT REFLECTOR DOWNLIGHT

DL202 238-239 DL203 240-241 DL300 242-243 DL310 244-245

RECESSED DEEP RECESSED DEEP RECESSED DEEP RECESSED GLASS


REFLECTOR DOWNLIGHT REFLECTOR DOWNLIGHT REFLECTOR DOWNLIGHT DIFFUSER

AR430 246-247 AR435 248-249 AR437 250-251 NSOFT 252-253


Fixed Recessed Spotlight
SERIES : AR4100
IP20
Technical Data

Physical Characteristics

Frequency
Voltage
Transformer

Accessories

Emergency
Lamp
Reference

Size
Number

Power
Factor
Model

/
Lamp

Type

Unit
W H C

watt V / Hz mm mm mm

20
QR-
CB51
3/NM
MT 3 hours
(Magnetic) Non-Maintained

35 220 - 240V
AR4100 1 QR- ------ ------ 83 58 70
CB51 50 / 60Hz

ET 3/M
(Electronic) 3 hours
Maintained
50
Suitable to be used in: of¿ces, lobbies, entrances, showrooms, corridors, circulation areas, stairs, waiting area QR-
Applications
in clinics, banks governmental premises, general lighting application, ... CB51

Made of die-cast aluminum, metal parts treated with a full degreasing and phosphate process. painted in
stove enameled baked epoxy
polyester mix-powder.
Zinc plated steel springs for ¿xing to the false ceiling.
Housing
- AR41001 – White rim
- AR41002 – Black rim
- AR41003 – Golden rim
- AR41004 – Chrome rim

Light Controller Clear tempered glass. Photometrics & Dimensions


Mounting Recessed in false ceiling.

AR4100
High quality Magnetic Transformer.
Control Gear High quality Electronic Transformer.
High quality Dimmable Electronic Transformer.

220v - 240v, 50 / 60Hz.


Voltage / Frequency
“Other Voltages upon request”

Cable Entry Direct connection.

Lamps 20, 35, 50 & 75 watt Halogen QR-CB 51 , 12v.

3 Hours duration Emergency Unit “EMU” with battery pack Maintained “/M” or Non-Maintained “/NM” for
Emergency Unit
Halogen lamp, and various voltage networks combinations.

224
Adjustable Recessed Spotlight
SERIES : AR4102
IP20
Technical Data
To Order : follow the sequence mr - ls - tt - v/h - emu

Physical Characteristics

Frequency
Voltage
Transformer

Accessories

Emergency
Lamp
Reference

Size
Number

Power
Factor
Model

/
Lamp

Type

Unit
W H C

watt V / Hz mm mm mm

20
QR-CB51
3/NM
MT 3 hours
(Magnetic) Non-Maintained

220 - 240V
35
AR4102 1 ------ ------ 100 58 87
QR-CB51
50 / 60Hz

ET 3/M
(Electronic) 3 hours
Maintained
50
Suitable to be used in: of¿ces, lobbies, entrances, showrooms, corridors, circulation areas, stairs, waiting area QR-CB51
Applications
in clinics, banks governmental premises, general lighting application, ...
Made of die-cast aluminum, metal parts treated with a full degreasing and phosphate process. painted in
stove enameled baked epoxy
polyester mix-powder.
Housing Zinc plated steel springs for ¿xing to the false ceiling.
- AR41021 – White rim
- AR41022 – Black rim
- AR41023 – Golden rim

Light Controller Clear tempered glass.


Photometrics & Dimensions
Mounting Recessed in false ceiling.

High quality Magnetic Transformer. AR4102


Control Gear High quality Electronic Transformer.
High quality Dimmable Electronic Transformer.

220v - 240v, 50 / 60Hz.


Voltage / Frequency
“Other Voltages upon request”

Cable Entry Direct connection.

Lamps 20, 35, 50 & 75 watt Halogen QR-CB 51 , 12v.

3 Hours duration Emergency Unit “EMU” with battery pack Maintained “/M” or Non-Maintained “/NM” for
Emergency Unit
Halogen lamp, and various voltage networks combinations.

226
Deep Recessed Spotlight
SERIES : AR4106
IP20
Technical Data

Physical Characteristics

Frequency
Voltage
Transformer

Accessories

Emergency
Lamp
Reference

Size
Number

Power
Factor
Model

/
Lamp

Type

Unit
W H C

watt V / Hz mm mm mm

20
QR-CB51
3/NM
MT 3 hours
(Magnetic) Non-Maintained

220 - 240V
35
AR4106 1 ------ ------ 90 72 77
QR-CB51
50 / 60Hz

ET 3/M
(Electronic) 3 hours
Maintained
50
Suitable to be used in: of¿ces, lobbies, entrances, showrooms, corridors, circulation areas, stairs, waiting area QR-CB51
Applications
in clinics, banks governmental premises, general lighting application, ...
Made of die-cast aluminum, metal parts treated with a full degreasing and phosphate process. painted in
stove enameled baked epoxy
polyester mix-powder.
Housing Zinc plated steel springs for ¿xing to the false ceiling.
- AR41061 – White rim
- AR41062 – Black rim
- AR41063 – Golden rim

Light Controller Clear tempered glass.


Photometrics & Dimensions
Mounting Recessed in false ceiling.

High quality Magnetic Transformer. AR4106


Control Gear High quality Electronic Transformer.
High quality Dimmable Electronic Transformer.

220v - 240v, 50 / 60Hz.


Voltage / Frequency
“Other Voltages upon request”

Cable Entry Direct connection.

Lamps 20, 35, 50 & 75 watt Halogen QR-CB 51 , 12v.

3 Hours duration Emergency Unit “EMU” with battery pack Maintained “/M” or Non-Maintained “/NM” for
Emergency Unit
Halogen lamp, and various voltage networks combinations.

228
Recessed Deep Reflector Downlight
SERIES : DL100
IP20
Technical Data
IP44
To Order : follow the sequence mr/at - ln/ls - cgt - v/h - pf - acc -emu

Physical Characteristics

Frequency
Voltage

Accessories
Attachment

Emergency
Lamp
Reference

Size

Optional
Number

Control

Power
Factor
Model

/
Lamp

Gear
Type

Unit
W H C

watt V / Hz mm mm mm

------ 229 148

1 13
FTB
HPF
Fused 3/NM
EB High
Terminal 3 hours
Electronic Power
Block Non-Maintained
High Factor
Frequency
220 - 240V
DL100 18 215
50 / 60Hz
AB EBD
RISC
Dimmable
Radio 3/M
Electronic HF
Interference 3 hours
AG High High
Suppression Maintained
Frequency Frequency
Capacitor 236 153
2 26
Suitable to be used in: of¿ces, lobbies, entrances, showrooms, corridors, circulation areas, stairs, waiting area
Applications AC
in clinics, banks governmental premises, general lighting application, ...

Made of high quality aluminum, painted in stove enameled white baked epoxy polyester mix-powder. AP
Housing “Other color ¿nishes upon request”

Vacuum metalized pure oxidized anode-process-polished aluminum reÀector, with or without protection
tempered glass.
- DL100/ A – without glass
Light Controller - DL100/AB – frosted (Sand Blasted) glass
- DL100/AG – clear glass
- DL100/AC – semi frosted Photometrics & Dimensions
- DL100/AP – printed / dot

Mounting Recessed in false ceiling.


DL100 /2/26w
High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.
Control Gear High Frequency Electronic Control Gear “ECG”.
High Frequency Dimmable Electronic Control Gear “ECG”.

220v - 240v, 50 / 60Hz.


Voltage / Frequency
“Other Voltages upon request”

1x22 mm Ø hole on the side of the control gear box.


Cable Entry
“Extra knock-out holes upon request”
13,18 & 26 watt TC-D/TC-T Compact Fluorescent for Normal Start “NS”,
Lamps
or TC-DE/TC-TE for Electronic High Frequency “HF” Ballast “EB”.
3 Hours duration Emergency Unit “EMU” with battery pack Maintained “/M” or Non-Maintained “/NM” for one
Emergency Unit lamp, and for various lamps types and voltage networks combinations.
“Additional Emergency Units to operate more than one lamp on request”

230
Recessed Shallow Reflector Downlight
SERIES : DL110
IP20
Technical Data
IP44
To Order : follow the sequence mr/at - ln/ls - cgt - v/h - pf - acc -emu
Physical Characteristics

Frequency
Voltage

Accessories
Attachment

Emergency
Lamp
Reference

Size

Optional
Number

Control

Power
Factor
Model

/
Lamp

Gear
Type

Unit
W H C

watt V / Hz mm mm mm

NS
Normal
Start

13D/T
------ 229 116
DEOS
Electronic
1
Starter FTB
3/NM
Fused
18D/T 3 hours
HPF Terminal
Non-
High Block
Maintained
RS Power
Rapid Factor
220 - 240V
Start
DL110 26D/T 215
50 / 60Hz
HF RISC
CB
EB High Radio
3/M
Electronic Frequency Interference
32T 3 hours
High Suppression
CC Maintained
Frequency Capacitor
2
Suitable to be used in: of¿ces, lobbies, entrances, showrooms, corridors, circulation areas, stairs, waiting area 236 116
Applications
in clinics, banks governmental premises, general lighting application, ... CG
42T
EBD
Dimmable
Made of high quality aluminum, painted in stove enameled white baked epoxy polyester mix-powder. CP
Housing Electronic
“Other color ¿nishes upon request” High
Frequency

Vacuum metalized pure oxidized anode-process-polished aluminum reÀector, with or without protection
tempered glass.
- DL110/ A – without glass
Light Controller - DL110/CB – frosted (sand blasted) glass
- DL110/CC – semi frosted glass
- DL110/CG – clear glass Photometrics & Dimensions
- DL110/CP – printed / dot

Mounting Recessed in false ceiling.


DL110 2/42W
High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.
Control Gear High Frequency Electronic Control Gear “ECG”.
High Frequency Dimmable Electronic Control Gear “ECG”.

220v - 240v, 50 / 60Hz.


Voltage / Frequency
“Other Voltages upon request”

1x22 mm Ø hole on the side of the control gear box.


Cable Entry
“Extra knock-out holes upon request”
15, 20 & 23 watt E27 Energy Saving Compact Fluorescent direct voltage lamps
13,18 & 26 watt TC-D/TC-T Compact Fluorescent for Normal Start “NS”,
Lamps
or TC-DE/TC-TE for Electronic High Frequency “HF” Ballast “EB”.
32 & 42 watt TC-TE for Electronic High Frequency “HF” Ballast “EB”.
3 Hours duration Emergency Unit “EMU” with battery pack Maintained “/M” or Non-Maintained “/NM” for one
Emergency Unit lamp, and for various lamps types and voltage networks combinations.
“Additional Emergency Units to operate more than one lamp on request”

232
Recessed Shallow Reflector Downlight
SERIES : DL200
IP20
Technical Data
To Order : follow the sequence mr/at - ln/ls - v/h

Physical Characteristics

Frequency
Voltage

Accessories
Attachment

Emergency
Lamp
Reference

Size
Number

Control

Power
Factor
Model

/
Lamp

Gear
Type

Unit
W H C

watt V / Hz mm mm mm

CB
1
15EL

CC
220 - 240V
DL200 20EL ------ ------ ------ ------ 220 116 200
50 / 60Hz
CG

23EL
2
Suitable to be used in: of¿ces, lobbies, entrances, showrooms, corridors, circulation areas, stairs, waiting area CP
Applications
in clinics, banks governmental premises, general lighting application, ...

Made of high quality aluminum, painted in stove enameled white baked epoxy polyester mix-powder.
Housing
“Other color ¿nishes upon request”

Vacuum metalized pure oxidized anode-process-polished aluminum reÀector, with protection tempered glass
- DL200/CB – frosted (sand blasted) glass
Light Controller - DL200/CC – semi frosted
- DL200/CG – clear
- DL200/CP – printed / dot
Photometrics & Dimensions
Mounting Recessed in false ceiling.

Control Gear Direct connection to the mains DL200 2/23w

220v - 240v, 50 / 60Hz.


Voltage / Frequency
“Other Voltages upon request”

Cable Entry 1x22 mm Ø hole on the side.

Lamps 15, 20 & 23 watt E27 Energy Saving Compact Fluorescent direct voltage lamps.

234
Recessed Shallow Reflector Downlight
SERIES : DL201
IP20
Technical Data
To Order : follow the sequence mr/at - ln/ls - cgt - v/h - pf - acc -emu

Physical Characteristics

Frequency
Voltage

Accessories
Attachment

Lamp
Reference

Size

Optional
Number

Control

Power
Factor
Model

/
Lamp

Gear
Type
W H C

watt V / Hz mm mm mm

MB

CCG
MG (Ballast+Igniter+Capacitor)
HPF FTB
220 - 240V
High Fused
DL201 1 70 163 67 144
Power Terminal
50 / 60Hz
Factor Block
MP ECG
(Electronic)

Suitable to be used in: of¿ces, lobbies, entrances, showrooms, corridors, circulation areas, stairs, waiting area MC
Applications
in clinics, banks governmental premises, general lighting application, ...

Made of high quality aluminum, painted in stove enameled white baked epoxy polyester mix-powder.
Housing
“Other color ¿nishes upon request”

Vacuum metalized pure oxidized anode-process-polished aluminum reÀector,


with protection tempered glass
- DL201/MB – frosted (sand blasted) glass
Light Controller
- DL201/MG – clear
- DL201/MP – printed / dot
- DL201/MC – semi frosted Photometrics & Dimensions
Mounting Recessed in false ceiling.

High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.


DL201 70w
Control Gear
High Frequency Electronic Control Gear “ECG”.

220v - 240v, 50 / 60Hz.


Voltage / Frequency
“Other Voltages upon request”

1x22 mm Ø hole on the side of the control gear box.


Cable Entry
“Extra knock-out holes upon request”

Lamps 70 watt RX7s Metal Halide double-ended lamp.

236
Recessed Shallow Reflector Downlight
SERIES : DL202
IP20
Technical Data
To Order : follow the sequence mr/at - ln/ls - cgt - v/h - pf - acc -emu
Physical Characteristics

Frequency
Voltage

Accessories
Attachment

Lamp
Reference

Size
Number

Control

Power
Factor
Model

/
Lamp

Gear
Type
W H C

watt V / Hz mm mm mm

CCG
MB 70
(Ballast+Igniter+Capacitor)

MG
HPF FTB
220 - 240V
High Fused
DL202 1 220 90 200
Power Terminal
50 / 60Hz
Factor Block
MP

ECG
MC 150
Suitable to be used in: of¿ces, lobbies, entrances, showrooms, corridors, circulation areas, stairs, waiting area (Electronic)
Applications
in clinics, banks governmental premises, general lighting application, ...

Made of high quality aluminum, painted in stove enameled white baked epoxy polyester mix-powder.
Housing
“Other color ¿nishes upon request”

Vacuum metalized pure oxidized anode-process-polished aluminum reÀector, with protection tempered glass
- DL202/MB – frosted (sand blasted) glass
Light Controller - DL202/MG – clear
- DL202/MP – printed / dot
- DL202/MC – semi frosted
Photometrics & Dimensions
Mounting Recessed in false ceiling.

High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.


Control Gear
High Frequency Electronic Control Gear “ECG”.
DL202 150w

220v - 240v, 50 / 60Hz.


Voltage / Frequency
“Other Voltages upon request”

1x22 mm Ø hole on the side of the control gear box.


Cable Entry
“Extra knock-out holes upon request”

Lamps 70 & 150 watt RX7s Metal Halide double-ended lamp.

238
Recessed Shallow Reflector Downlight
SERIES : DL203
IP20
Technical Data
To Order : follow the sequence mr/at - ln/ls - cgt - v/h - pf - acc -emu

Physical Characteristics

Frequency
Voltage

Accessories
Attachment

Emergency
Lamp
Reference

Size

Optional
Number

Control

Power
Factor
Model

/
Lamp

Gear
Type

Unit
W H C

watt V / Hz mm mm mm

13D/T

CB
1
FTB
HPF 3/NM
EB Fused
18D/T High 3 hours
Electronic Terminal
Power Non-
High Block
Factor Maintained
CC Frequency
220 - 240V
DL203 26D/T 220 116 200
50 / 60Hz
EBD
CG Dimmable RISC
Electronic Radio
HF 3/M
High Interference
32T High 3 hours
Frequency Suppression
Frequency Maintained
Capacitor
2
Suitable to be used in: of¿ces, lobbies, entrances, showrooms, corridors, circulation areas, stairs, waiting area CP
Applications
in clinics, banks governmental premises, general lighting application, ...
42T

Made of high quality aluminum, painted in stove enameled white baked epoxy polyester mix-powder.
Housing
“Other color ¿nishes upon request”

Vacuum metalized pure oxidized anode-process-polished aluminum reÀector. with protection tempered glass.
- DL203/CB – frosted (sand blasted) glass
Light Controller - DL203/CC – semi frosted
- DL203/CG – clear
- DL203/CP – printed / dot
Photometrics & Dimensions
Mounting Recessed in false ceiling.

High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.


Control Gear High Frequency Electronic Control Gear “ECG”. DL203 2/32w
High Frequency Dimmable Electronic Control Gear “ECG”.

220v - 240v, 50 / 60Hz.


Voltage / Frequency
“Other Voltages upon request”

1x22 mm Ø hole on the side of the control gear box.


Cable Entry
“Extra knock-out holes upon request”
15, 20 & 23 watt E27 Energy Saving Compact Fluorescent direct voltage lamps
13,18 & 26 watt TC-D/TC-T Compact Fluorescent for Normal Start “NS”,
Lamps
or TC-DE/TC-TE for Electronic High Frequency “HF” Ballast “EB”.
32 & 42 watt TC-TE for Electronic High Frequency “HF” Ballast “EB”.
3 Hours duration Emergency Unit “EMU” with battery pack Maintained “/M” or Non-Maintained “/NM” for one
Emergency Unit lamp, and for various lamps types and voltage networks combinations.
“Additional Emergency Units to operate more than one lamp on request”

240
Recessed Shallow Reflector Downlight
SERIES : DL300
IP44
Technical Data
To Order : follow the sequence mr/at - ln/ls - cgt - v/h - pf - acc -emu

Physical Characteristics

Frequency
Voltage

Accessories
Attachment

Emergency
Lamp
Reference

Size

Optional
Number

Control

Power
Factor
Model

/
Lamp

Gear
Type

Unit
W H C

watt V / Hz mm mm mm

13D/T

AB
1
FTB
3/NM
EB Fused
18D/T 3 hours
Electronic HPF Terminal
Non-
High High Block
Maintained
AC Frequency Power
Factor
220 - 240V
DL300 26D/T 236 153 215
50 / 60Hz
EBD
AG Dimmable HF RISC
Electronic High Radio
3/M
High Frequency Interference
32T 3 hours
Frequency Suppression
Maintained
Capacitor
2
Suitable to be used in: of¿ces, lobbies, entrances, showrooms, corridors, circulation areas, stairs, waiting area AP
Applications
in clinics, banks governmental premises, general lighting application, ...
42T
Made of high quality die-cast aluminum with mechanical bracket for ¿xing glass diffuser, painted in stove
enameled white baked epoxy polyester mix-powder.
Housing
“Other color ¿nishes upon request”
Vacuum metalized pure oxidized anode-process polished aluminum reÀector, with protection tempered glass.
- DL300/AB – frosted (sand blasted) glass
Light Controller - DL300/AC – semi frosted
- DL300/AG – clear
- DL300/AP – printed / dot
Photometrics & Dimensions
Mounting Recessed in false ceiling.

High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.


Control Gear High Frequency Electronic Control Gear “ECG”. DL300 2/18w
High Frequency Dimmable Electronic Control Gear “ECG”.

220v - 240v, 50 / 60Hz.


Voltage / Frequency
“Other Voltages upon request”

1x22 mm Ø hole on the side of the control gear box.


Cable Entry
“Extra knock-out holes upon request”
13,18 & 26 watt TC-D/TC-T Compact Fluorescent for Normal Start “NS”,
Lamps
or TC-DE/TC-TE for Electronic High Frequency “HF” Ballast “EB”.
3 Hours duration Emergency Unit “EMU” with battery pack Maintained “/M” or Non-Maintained “/NM” for one
Emergency Unit lamp, and for various lamps types and voltage networks combinations.
“Additional Emergency Units to operate more than one lamp on request”

242
Recessed Shallow Reflector Downlight
SERIES : DL310
IP44
Technical Data
To Order : follow the sequence mr/at - ln/ls - cgt - v/h - pf - acc -emu

Physical Characteristics

Frequency
Voltage

Accessories
Attachment

Emergency
Lamp
Reference

Size

Optional
Number

Control

Power
Factor
Model

/
Lamp

Gear
Type

Unit
W H C

watt V / Hz mm mm mm

13D/T
1
FTB
AB
EB Fused 3/NM
Electronic HPF Terminal 3 hours
High High Block Non-Maintained
Frequency Power
AC
Factor
220 - 240V
18D/T
DL310 236 153 215
50 / 60Hz
EBD
AG
Dimmable HF RISC
Electronic High Radio 3/M
High Frequency Interference 3 hours
Frequency Suppression Maintained
AP
26D/T Capacitor
2
Suitable to be used in: of¿ces, lobbies, entrances, showrooms, corridors, circulation areas, stairs, waiting area
Applications
in clinics, banks governmental premises, general lighting application, ...

Made of high quality aluminum, painted in stove enameled white baked epoxy polyester mix-powder.
Housing
“Other color ¿nishes upon request”

Vacuum metalized pure oxidized anode-process-polished aluminum reÀector, with or without protection
tempered glass.
- DL310 – without protection glass
Light Controller - DL310/AB – frosted (sand blasted)
- DL310/AC – semi frosted
- DL310/AG – clear Photometrics & Dimensions
- DL310/AP – printed / dot

Mounting Recessed in false ceiling.


DL310 2/32w
High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.
Control Gear High Frequency Electronic Control Gear “ECG”.
High Frequency Dimmable Electronic Control Gear “ECG”.

220v - 240v, 50 / 60Hz.


Voltage / Frequency
“Other Voltages upon request”

1x22 mm Ø hole on the side of the control gear box.


Cable Entry
“Extra knock-out holes upon request”
15, 20 & 23 watt E27 Energy Saving Compact Fluorescent direct voltage lamps
13,18 & 26 watt TC-D/TC-T Compact Fluorescent for Normal Start “NS”,
Lamps
or TC-DE/TC-TE for Electronic High Frequency “HF” Ballast “EB”.
32 & 42 watt TC-TE for Electronic High Frequency “HF” Ballast “EB”.
3 Hours duration Emergency Unit “EMU” with battery pack Maintained “/M” or Non-Maintained “/NM” for one
Emergency Unit lamp, and for various lamps types and voltage networks combinations.
“Additional Emergency Units to operate more than one lamp on request”

244
Recessed Deep Reflector Downlight
SERIES : AR430
IP20
Technical Data
To Order : follow the sequence mr/rrc - ln/ls - cgt - v/h - pf - acc -emu

Physical Characteristics

Frequency
Voltage

Accessories

Emergency
Lamp
Reference

Size
ReÀector

Optional
Number

Control

Power
Factor
Model

/
Lamp
Color

Gear
Type
Rim

Unit
W H C

watt V / Hz mm mm mm

11 40GLS
60GLS
75GLS
12 LPF
100GLS
Low
150GLS
Power
13 Factor
FTB
60QT32 3/NM
Fused
75QT32 3 hours
14 Terminal
100QT32 Non-
HPF Block
Maintained
High
EB Power
15EL 220 - 240V
Electronic Factor
AR430 1 20EL 195 200 185
High
23EL 50 / 60Hz
Frequency
RISC
21
Suitable to be used in: of¿ces, lobbies, entrances, showrooms, corridors, circulation areas, stairs, waiting area HF Radio
Applications High Interference
3/M
in clinics, banks governmental premises, general lighting application, ... 50HM 3 hours
Frequency Suppression
22 80HM Maintained
Made of die-cast aluminum, metal parts treated with a full degreasing and phosphate process. painted in Capacitor
stove enameled baked epoxy
Housing (white, black, golden and chrome) polyester mix-powder. Equipped with mechanism for adjusting lamp holder LF
23 70HL
Low
position, allowing the use of lamps of different shapes and sizes. Zinc plated steel springs for ¿xing to the
Frequency
false ceiling.
24 50HS
Pure aluminum reÀector. 70HS
AR4301 Golden Aluminum ReÀector:
- AR43011 – Golden ReÀector with White Rim.
- AR43012 – Golden ReÀector with Black Rim.
- AR43013 – Golden ReÀector with Golden Rim.
Light Controller - AR43014 – Golden ReÀector with Chrome Rim.
AR4302 Silver Aluminum ReÀector:
- AR43021 – Silver ReÀector with White Rim.
- AR43022 – Silver ReÀector with Black Rim. Photometrics & Dimensions
- AR43023 – Silver ReÀector with Golden Rim.
- AR43024 – Silver ReÀector with Chrome Rim.

Mounting Recessed in false ceiling. AR430 150w


High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.
Control Gear High Frequency Electronic Control Gear “ECG”.
High Frequency Dimmable Electronic Control Gear “ECG”.
220v - 240v, 50 / 60Hz.
Voltage / Frequency
“Other Voltages upon request”
1x22 mm Ø hole on the side of the control gear box.
Cable Entry
“Extra knock-out holes upon request”
150 watt Incandescent GLS E27 -- Max
100 watt QT-32 Quartz Tube E27 – Max
15, 20 & 23 watt EL Energy Saving E27
13 &18 watt TC-D Compact Fluorescent for Normal Start “NS”,
Lamps
or TC-DE for Electronic High Frequency “HF” Ballast “EB”.
50 & 80 watt HME High Pressure Mercury Vapor E27.
70 watt HIE/HIT Metal Halide E27.
50 & 70 watt HSE/HST High Pressure Sodium E27.
3 Hours duration Emergency Unit “EMU” with battery pack Maintained “/M” or Non-Maintained “/NM” for CF
Emergency Unit
lamps, and various voltage networks combinations.

246
Recessed Deep Reflector Downlight
SERIES : AR435
IP20
Technical Data
To Order : follow the sequencem mr/rrc - ln/ls - cgt - v/h - pf - acc -emu

Physical Characteristics

Frequency
Voltage

Accessories

Emergency
Lamp
Reference

Size
ReÀector

Optional
Number

Control

Power
Factor
Model

/
Lamp
Color

Gear
Type
Rim

Unit
W H C

watt V / Hz mm mm mm

11

LPF
12
Low
Power
40GLS Factor
13
60GLS FTB
3/NM
75GLS EB Fused
3 hours
100GLS Electronic Terminal
14 Non-
High HPF Block
Maintained
Frequency High
60QT32 Power
220 - 240V
75QT32 Factor
AR435 1 168 180 165
50 / 60Hz
EBD
15EL Dimmable RISC
Suitable to be used in: of¿ces, lobbies, entrances, showrooms, corridors, circulation areas, stairs, waiting area 21
Applications 20EL Electronic HF Radio
3/M
in clinics, banks governmental premises, general lighting application, ... High High Interference
3 hours
Frequency Frequency Suppression
Made of die-cast aluminum, metal parts treated with a full degreasing and phosphate process. painted in 22 Maintained
13D Capacitor
stove enameled baked epoxy 18D
Housing (white, black, golden and chrome) polyester mix-powder. Equipped with mechanism for adjusting lamp holder LF
23
position, allowing the use of lamps of different shapes and sizes. Zinc plated steel springs for ¿xing to the Low
false ceiling. Frequency

Pure aluminum reÀector. 24


AR4351 Golden Aluminum ReÀector:
- AR43511 – Golden ReÀector with White Rim.
- AR43512 – Golden ReÀector with Black Rim.
- AR43513 – Golden ReÀector with Golden Rim.
Light Controller - AR43514 – Golden ReÀector with Chrome Rim.
AR4352 Silver Aluminum ReÀector:
- AR43521 – Silver ReÀector with White Rim.
- AR43522 – Silver ReÀector with Black Rim.
- AR43523 – Silver ReÀector with Golden Rim.
Photometrics & Dimensions
- AR43524 – Silver ReÀector with Chrome Rim.

Mounting Recessed in false ceiling.


AR435 100w GLS
High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.
Control Gear High Frequency Electronic Control Gear “ECG”.
High Frequency Dimmable Electronic Control Gear “ECG”.

220v - 240v, 50 / 60Hz.


Voltage / Frequency
“Other Voltages upon request”

1x22 mm Ø hole on the side of the control gear box.


Cable Entry
“Extra knock-out holes upon request”
100 watt Incandescent GLS E27 -- Max
75 watt QT-32 Quartz Tube E27 – Max
15 & 20 watt EL Energy Saving E27
Lamps 13 watt TC-D Compact Fluorescent for Normal Start “NS”,
or TC-DE for Electronic High Frequency “HF” Ballast “EB”.
50 watt HME High Pressure Mercury Vapor E27.
50 watt HSE/HST High Pressure Sodium E27.
3 Hours duration Emergency Unit “EMU” with battery pack Maintained “/M” or Non-Maintained “/NM” for CF
Emergency Unit
lamps, and various voltage networks combinations.

248
Recessed Deep Reflector Downlight
SERIES : AR437
IP20
Technical Data
To Order : follow the sequence mr/rrc - ln/ls - cgt - v/h - pf - acc -emu
Physical Characteristics

Frequency
Voltage

Accessories

Emergency
Lamp
Reference

Size
ReÀector

Optional
Number

Control

Power
Factor
Model

/
Lamp
Color

Gear
Type
Rim

Unit
W H C

watt V / Hz mm mm mm

11

12

13
FTB
40GLS 3/NM
Fused
LPF 3 hours
Terminal
14 Low Non-
Block
Power Factor Maintained
NS
15EL 220 - 240V
Normal
AR437 1 125 180 105
Start
50 / 60Hz
HPF
RISC
21 High
Radio
5S/E Power 3/M
Interference
7S/E Factor 3 hours
Suppression
22 9S/E Maintained
Suitable to be used in: of¿ces, lobbies, entrances, showrooms, corridors, circulation areas, stairs, waiting area Capacitor
Applications
in clinics, banks governmental premises, general lighting application, ...
23
Made of die-cast aluminum, metal parts treated with a full degreasing and phosphate process. painted in
stove enameled baked epoxy
Housing (white, black, golden and chrome) polyester mix-powder. Equipped with mechanism for adjusting lamp holder 24
position, allowing the use of lamps of different shapes and sizes. Zinc plated steel springs for ¿xing to the
false ceiling.
Pure aluminum reÀector.
AR4371 Golden Aluminum ReÀector:
- AR43711 – Golden ReÀector with White Rim.
- AR43712 – Golden ReÀector with Black Rim.
- AR43713 – Golden ReÀector with Golden Rim.
Light Controller - AR43714 – Golden ReÀector with Chrome Rim.
AR4372 Silver Aluminum ReÀector: Photometrics & Dimensions
- AR43721 – Silver ReÀector with White Rim.
- AR43722 – Silver ReÀector with Black Rim.
- AR43723 – Silver ReÀector with Golden Rim.
- AR43724 – Silver ReÀector with Chrome Rim.
AR437 15w EL
Mounting Recessed in false ceiling.

High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.


Control Gear High Frequency Electronic Control Gear “ECG”.
High Frequency Dimmable Electronic Control Gear “ECG”.

220v - 240v, 50 / 60Hz.


Voltage / Frequency
“Other Voltages upon request”

1x22 mm Ø hole on the side of the control gear box.


Cable Entry
“Extra knock-out holes upon request”
40 watt Incandescent GLS E27 -- Max
15 watt EL Energy Saving E27
Lamps
5, 7 & 9 watt TC-S Compact Fluorescent for Normal Start “NS”,
or TC-SE for Electronic High Frequency “HF” Ballast “EB”.
3 Hours duration Emergency Unit “EMU” with battery pack Maintained “/M” or Non-Maintained “/NM” for CF
Emergency Unit
lamps, and various voltage networks combinations.

250
Recessed Glass Diffuser
SERIES : NSOFT
IP20
Technical Data
To Order : follow the sequence mr - ln/ls - cgt - v/h - pf - acc -emu
Physical Characteristics

Frequency
Voltage

Accessories

Emergency
Lamp
Reference

Size

Optional
Number

Control

Power
Factor
Model

/
Lamp

Gear
Type

Unit
L W H C

watt V / Hz mm mm mm mm

13D/T
1
18D/T
3/NM
26D/T 270 270 54 230x230
3 hours
Non-
32T
Maintained
2 HPF
42T High
EB Power
Electronic Factor
High
1 600 160 590x150
Frequency
36L
FTB 3/M
220 - 240V
HF Fused 3 hours
NSOFT 40L 53
High Terminal Maintained
50 / 60Hz
EBD Frequency Block
55L
2 Dimmable 545 270 500x230
Electronic
High
Frequency LF
Suitable to be used in: of¿ces, lobbies, entrances, showrooms, corridors, circulation areas, stairs, waiting area Low
Applications
in clinics, banks governmental premises, general lighting application, ... Frequency
70CCG
Made of press welded Cold Rolled Steel “CRS” sheet of tight construction to prevent light leakage, all metal
parts pre-treated with a full degreasing and phosphate process, painted in stove enameled white baked epoxy 1 ------ 270 270 74 230x230
Housing polyester mix-powder to ensure high reÀectance of painted surfaces.
“Other color ¿nishes upon request” 150CCG

Drop semi-frosted tempered glass diffuser with high mechanical impact.


Light Controller
Diffuser is held to the body by means of four stainless steel locking nut’s.

Mounting Recessed in false ceiling.

High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.


Photometrics & Dimensions
Control Gear High Frequency Electronic Control Gear “ECG”.
High Frequency Dimmable Electronic Control Gear “ECG”.

NSOFT 2/36wL
220v - 240v, 50 / 60Hz.
Voltage / Frequency
“Other Voltages upon request”

1x22 mm Ø hole on top.


Cable Entry
“Extra knock-out holes upon request”
13, 18 & 26 watt TC-D/TC-T Compact Fluorescent for Normal Start “NS”
13, 18 & 26 watt TC-DE/TC-TE Compact Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
Lamps 13, 18, 26, 32, 42, 57 & 70 watt TC-TE Compact Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
18, 24, 36, 40, 55 & 80 watt TC-L Compact Fluorescent for Electronic High Frequency “HF” Ballast “EB”.
70 & 150 watt RX7s Metal Halide double-ended lamp.
3 Hours duration Emergency Unit “EMU” with battery pack Maintained “/M” or Non-Maintained “/NM” for one
Emergency Unit lamp, and for various lamps types and voltage networks combinations.
“Additional Emergency Units to operate more than one lamp on request”

252
Surface Deep Reflector Downlight
SERIES : S100
IP20
Technical Data
IP44
To Order : follow the sequence mr/at - ln/ls - cgt - v/h - pf - acc -emu

Physical Characteristics

Frequency
Voltage

Accessories
Attachment

Emergency
Lamp
Reference

Size

Optional
Number

Control

Power
Factor
Model

/
Lamp

Gear
Type

Unit
W H C

watt V / Hz mm mm mm

--------
------
3/NM
3 hours
1
FTB Non-
EB Fused Maintained
13D/T
Electronic HPF Terminal
High High Block
Frequency Power
Factor
220 - 240V
S100 18D/T 242 170 --
50 / 60Hz
EBD 3/M
GC
Dimmable HF RISC 3 hours
Electronic High Radio Maintained
High Frequency Interference
GD 26D/T
Frequency Suppression
Suitable to be used in: of¿ces, lobbies, entrances, showrooms, corridors, circulation areas, stairs, waiting area
Applications 2
Capacitor
in clinics, banks governmental premises, general lighting application, ... --------
GF
Only in a
Made of high quality aluminum, painted in stove enameled white baked epoxy polyester mix-powder. remote box
Housing GS
“Other color ¿nishes upon request”

Vacuum metalized pure oxidized anode-process-polished aluminum reÀector,


with or without protection tempered glass.
- S100 – without protection glass
Light Controller - S100/G – clear
- S100/B – frosted (sand blasted)
- S100/D – semi frosted
- S100/P – printed / Dot
Photometrics & Dimensions
Mounting Surface in the ceiling.

High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.


Control Gear High Frequency Electronic Control Gear “ECG”. S 100 2/26w
High Frequency Dimmable Electronic Control Gear “ECG”.

220v - 240v, 50 / 60Hz.


Voltage / Frequency
“Other Voltages upon request”

1x22 mm Ø hole on top.


Cable Entry
“Extra knock-out holes upon request”
13,18 & 26 watt TC-D/TC-T Compact Fluorescent for Normal Start “NS”,
Lamps
or TC-DE/TC-TE for Electronic High Frequency “HF” Ballast “EB”.
3 Hours duration remote Emergency Unit “EMU” with battery pack Maintained “/M” or Non-Maintained “/NM”
Emergency Unit
for CF lamps, and various voltage networks combinations.

254
Surface Shallow Reflector Downlight
SERIES : SS100
IP20
Technical Data
IP44
To Order : follow the sequence mr/at - ln/ls - cgt - v/h - pf - acc -emu

Physical Characteristics

Frequency
Voltage

Accessories
Attachment

Emergency
Lamp
Reference

Size
Number

Control

Power
Factor
Model

/
Lamp

Gear
Type

Unit
W H C

watt V / Hz mm mm mm

--------
13D/T
------ 3/NM
LPF 3 hours
1
Low FTB Non-
Power Factor Fused Maintained
18D/T EB
Terminal
Electronic
Block
High
Frequency
HPF
220 - 240V
High
SS100 26D/T 242 115 --
Power
50 / 60Hz
Factor 3/M
EBD
RISC 3 hours
GC Dimmable
Radio Maintained
Electronic
Interference
32T High
Suitable to be used in: of¿ces, lobbies, entrances, showrooms, corridors, circulation areas, stairs, waiting area HF Suppression
Applications GD Frequency
in clinics, banks governmental premises, general lighting application, ... High Capacitor
2
Frequency --------
GF
Only in a
Made of high quality aluminum, painted in stove enameled white baked epoxy polyester mix-powder. 42T
remote box
Housing
“Other color ¿nishes upon request”
GS

Vacuum metalized pure oxidized anode-process-polished aluminum reÀector,


with or without protection tempered glass.
- SS100 – without protection glass
Light Controller - SS100/G – clear glass
- SS100/B – frosted
- SS100/D – semi frosted
- SS100/P – printed
Photometrics & Dimensions
Mounting Surface in the ceiling.

High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.


Control Gear High Frequency Electronic Control Gear “ECG”. SS100 2/26w
High Frequency Dimmable Electronic Control Gear “ECG”.

220v - 240v, 50 / 60Hz.


Voltage / Frequency
“Other Voltages upon request”

1x22 mm Ø hole on top.


Cable Entry
“Extra knock-out holes upon request”
13,18 & 26 watt TC-D/TC-T Compact Fluorescent for Normal Start “NS”,
Lamps
or TC-DE/TC-TE for Electronic High Frequency “HF” Ballast “EB”.
3 Hours duration remote Emergency Unit “EMU” with battery pack Maintained “/M” or Non-Maintained “/NM”
Emergency Unit
for CF lamps, and various voltage networks combinations.

256
Surface Cylindrical Downlight
SERIES : 301
Technical Data
IP20 To Order : follow the sequence mr s/at - ln/ls - cgt - v/h - pf - emu
Physical

Frequency
Voltage
Characteristics

Accessories
Attachment

Emergency
Lamp
Reference

Size
Number

Control
IP65

Power
Factor
Model

/
Lamp

Gear
Type
Size

Unit
W H

watt V / Hz mm mm

60PAR38
-- 80PAR38
120PAR38
60GLS
75GLS
100GLS
150GLS
0 130 200
60QT32
S 75QT32 LPF
--------
100QT32 Low
NS
Power Factor
Normal 3/NM
15EL
Start 3 hours
20EL
Non-Maintained
23EL
SG 13D/T HPF
18D/T High
26D/T Power
32T Factor
220 - 240V
301 1 42T ------
50 / 60Hz 3/M
SB 50HM 3 hours
80HM HF
Suitable to be used in: of¿ces, lobbies, entrances, showrooms, corridors, circulation areas, stairs, waiting area 1 Maintained 150 300
Applications 125HM High
in clinics, banks governmental premises, general lighting application, ... Frequency
EB
70HL Electronic
100HL High --------
Made of high quality aluminum, painted in stove enameled white or black baked epoxy polyester mix-powder. SD 150HL
Housing Frequency
Cylindrical pro¿le with robust structure. “Other color ¿nishes upon request” LF
Only in a remote
50HS Low
box
70HS Frequency
Open type without reÀector for PAR lamps or with high quality vacuum metalized pure oxidized anode- 57T
process-polished aluminum reÀector and 70T
with or without protection tempered glass. SP
- 301x – without reÀector & glass 250HM
Light Controller - 301x/S – with reÀector but w/out glass 2 220 365
- 301x/SG – with reÀector & safety glass 250HL
- 301x/SB – with reÀector & frosted safety glass
100HS
- 301x/SD – with reÀector & semi frosted 150HS
- 301x/SP – with reÀector & printed / Dot

Mounting Surface on ceiling.

High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”. Photometrics & Dimensions
Control Gear High Frequency Electronic Control Gear “ECG”.
High Frequency Dimmable Electronic Control Gear “ECG”.

220v - 240v, 50 / 60Hz. 301 250w HIE


Voltage / Frequency
“Other Voltages upon request”

Cable Entry 1x22 mm Ø hole on top. “Extra knock-out holes upon request”

3010/xx - 150 watt Incandescent GLS E27 – Max


120 watt PAR 38 E27 -- Max
100 watt QT-32 Quartz Tube E27 – Max
15, 20 & 23 watt EL Energy Saving E27
3011/xx -13,18 & 26 watt TC-D/TC-T Compact Fluorescent for Normal Start “NS”, or TC-DE/TC-TE for
Electronic High Frequency “HF” Ballast “EB”.
32 & 42 watt TC-TE for Electronic High Frequency “HF” Ballast “EB”.
Lamps
50, 80 & 125 watt HME High Pressure Mercury Vapor E27,
70, 100 & 150 watt HIE/HIT Metal Halide E27.
50 & 70 watt HSE/HST High Pressure Sodium E27.
3012/xx –57 & 70 watt TC-TE for Electronic High Frequency “HF” Ballast “EB”.
250 watt HME High Pressure Mercury Vapor E40,
250 watt HIE/HIT Metal Halide E40.
100, 150 & 250 watt HSE/HST High Pressure Sodium E40.
3 Hours duration remote Emergency Unit “EMU” with battery pack Maintained “/M” or Non-Maintained “/NM”
Emergency Unit
for CF lamps, and various voltage networks combinations.

258
Surface Square Downlight
SERIES : 501
Technical Data
IP20 To Order : follow the sequence mr s/at - ln/ls - cgt - v/h - pf - emu
Physical

Frequency
Voltage
Characteristics

Accessories
Attachment

Emergency
Lamp
Reference

Size
Number

Control

Power
Factor
Model

/
Lamp

Gear
Type
Size

Unit
W H

watt V / Hz mm mm
60PAR38
-- 80PAR38
120PAR38
60GLS
75GLS
100GLS
150GLS
0 140 200
60QT32
75QT32 LPF
100QT32 --------
Low
NS
Power Factor
15EL Normal 3/NM
20EL Start 3 hours
23EL Non-Maintained
13D/T HPF
18D/T High
26D/T Power
32T Factor
220 - 240V
501 1 42T ------
R 50 / 60Hz 3/M
50HM 3 hours
80HM HF
1 Maintained 200 300
Suitable to be used in: of¿ces, lobbies, entrances, showrooms, corridors, circulation areas, stairs, waiting area 125HM High
Applications Frequency
in clinics, banks governmental premises, general lighting application, ... EB
70HL Electronic
100HL High --------
Made of high quality aluminum, painted in stove enameled white or black 150HL Frequency
Housing baked epoxy polyester mix-powder. Rectangular pro¿le with robust structure. LF
Only in a remote
50HS Low
“Other color ¿nishes upon request” Frequency
box
70HS
57T
Open type without reÀector for PAR lamps or with high quality vacuum metalized pure oxidized anode- 70T
process-polished aluminum reÀector.
Light Controller
- 501x – without reÀector 250HM
- 501x/R – with reÀector 2 320 365
250HL
Mounting Surface on ceiling.
100HS
150HS
High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.
Control Gear High Frequency Electronic Control Gear “ECG”.
High Frequency Dimmable Electronic Control Gear “ECG”.

220v - 240v, 50 / 60Hz.


Photometrics & Dimensions
Voltage / Frequency
“Other Voltages upon request”

Cable Entry 1x22 mm Ø hole on top. “Extra knock-out holes upon request”
5010 120w PAR38 FL

5010/xx - 150 watt Incandescent GLS E27 – Max


120 watt PAR 38 E27 -- Max
100 watt QT-32 Quartz Tube E27 – Max
15, 20 & 23 watt EL Energy Saving E27
5011/xx - 13,18 & 26 watt TC-D/TC-T Compact Fluorescent for Normal Start “NS”, or TC-DE/TC-TE for
Electronic High Frequency “HF” Ballast “EB”.
32 & 42 watt TC-TE for Electronic High Frequency “HF” Ballast “EB”.
50 & 80 watt HME High Pressure Mercury Vapor E27,
Lamps
70 watt HIE/HIT Metal Halide E27.
50 & 70 watt HSE/HST High Pressure Sodium E27.
5012/xx – 125 watt HME High Pressure Mercury Vapor E27,
100 & 150 watt HIE/HIT Metal Halide E27.
5013/xx – 57 & 70 watt TC-TE for Electronic High Frequency “HF” Ballast “EB”.
250 watt HME High Pressure Mercury Vapor E40,
250 watt HIE/HIT Metal Halide E40.
100, 150 & 250 watt HSE/HST High Pressure Sodium E40.
3 Hours duration remote Emergency Unit “EMU” with battery pack Maintained “/M” or Non-Maintained “/NM”
Emergency Unit
for CF lamps, and various voltage networks combinations.

260
Wall Cylindrical Up-Downlight
SERIES : 303
Technical Data
IP20 To Order : follow the sequence mr s/at - ln/ls - cgt - v/h - pf - emu
Physical

Frequency
Voltage
Characteristics

Accessories
Attachment

Emergency
Lamp
Reference

Size
Number

Control

Power
Factor
Model

/
Lamp

Gear
Type
Size

Unit
W H

watt V / Hz mm mm

60PAR38
-- 80PAR38
120PAR38
60GLS
75GLS
100GLS
150GLS
0 130 370
60QT32
S 75QT32 LPF --------
100QT32 Low
NS
Power Factor 3/NM
15EL Normal
3 hours
20EL Start
Non-
23EL Maintained
SG 13D/T HPF
18D/T High
26D/T Power
32T Factor
220 - 240V
303 2 42T ------
50 / 60Hz
SB 50HM 3/M
80HM HF 3 hours
Suitable to be used in: of¿ces, lobbies, entrances, showrooms, corridors, circulation areas, stairs, waiting area 1 High Maintained 150 600
Applications 125HM
in clinics, banks governmental premises, general lighting application, ... Frequency
EB
70HL Electronic
100HL High
Made of high quality aluminum, painted in stove enameled white or black SD 150HL --------
Frequency
Housing baked epoxy polyester mix-powder. Cylindrical pro¿le with robust structure. “Other color ¿nishes upon LF
request” 50HS Low Only in a
70HS Frequency remote box
Open type without reÀector for PAR lamps or with high quality vacuum metalized pure oxidized anode- 57T
process-polished aluminum reÀector and 70T
SP
with or without protection tempered glass.
- 303x – without reÀector & glass 250HM
2 220 700
Light Controller - 303x/S – with reÀector but w/out glass
250HL
- 303x/SG – with reÀector & safety glass
- 303x/SB – with reÀector & frosted safety glass 100HS
- 303x/SD – with reÀector & semi frosted 150HS
- 303x/SP – with reÀector & printed / Dot

Mounting Surface wall mounted.

High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.


Photometrics & Dimensions
Control Gear High Frequency Electronic Control Gear “ECG”.
High Frequency Dimmable Electronic Control Gear “ECG”.
220v - 240v, 50 / 60Hz. 3032 2/70w HIE
Voltage / Frequency
“Other Voltages upon request”

Cable Entry 1x22 mm Ø hole on top. “Extra knock-out holes upon request”

3030/xx - 150 watt Incandescent GLS E27 – Max


120 watt PAR 38 E27 -- Max
100 watt QT-32 Quartz Tube E27 – Max
15, 20 & 23 watt EL Energy Saving E27
3031/xx - 13,18 & 26 watt TC-D/TC-T Compact Fluorescent for Normal Start “NS”, or TC-DE/TC-TE for
Electronic High Frequency “HF” Ballast “EB”.
32 & 42 watt TC-TE for Electronic High Frequency “HF” Ballast “EB”.
Lamps
50, 80 & 125 watt HME High Pressure Mercury Vapor E27,
70, 100 & 150 watt HIE/HIT Metal Halide E27.
50 & 70 watt HSE/HST High Pressure Sodium E27.
-3032/xx –57 & 70 watt TC-TE for Electronic High Frequency “HF” Ballast “EB”.
250 watt HME High Pressure Mercury Vapor E40,
250 watt HIE/HIT Metal Halide E40.
100, 150 & 250 watt HSE/HST High Pressure Sodium E40.

Emergency Unit Applicable only for remote mounting (indoor) with CFL lamp version

262
Wall Cylindrical Downlight
SERIES : 304
Technical Data
IP20 To Order : follow the sequence mr s/at - ln/ls - cgt - v/h - pf - emu
Physical

Frequency
Voltage
Characteristics

Accessories
Attachment

Emergency
Lamp
Reference

Size
Number
IP65

Control

Power
Factor
Model

/
Lamp

Gear
Type
Size

Unit
W H

watt V / Hz mm mm

60PAR38
-- 80PAR38
120PAR38
60GLS
75GLS
100GLS
150GLS
0 130 200
60QT32
S 75QT32 --------
100QT32
NS
3/NM
15EL Normal
3 hours
20EL Start
Non-
23EL Maintained
SG 13D/T HPF
18D/T High
26D/T Power
32T Factor
220 - 240V
42T
304 1 ------
50 / 60Hz
SB 50HM 3/M
Suitable to be used in: of¿ces, lobbies, entrances, showrooms, corridors, circulation areas, stairs, waiting area 1
80HM HF 3 hours
150 300
Applications 125HM High Maintained
in clinics, banks governmental premises, general lighting application, ...
Frequency
EB
70HL
Electronic
Made of high quality aluminum, painted in stove enameled white or black 100HL
High
Housing baked epoxy polyester mix-powder. Cylindrical pro¿le with robust structure. “Other color ¿nishes upon SD 150HL
Frequency
--------
request”
50HS Only in a
70HS remote box
Open type without reÀector for PAR lamps or with high quality vacuum metalized pure oxidized anode-
process-polished aluminum reÀector and 57T
70T
with or without protection tempered glass. SP
- 304x – without reÀector & glass 250HM
Light Controller - 304x/S – with reÀector but w/out glass 2 220 320
- 304x/SG – with reÀector & safety glass 250HL
- 304x/SB – with reÀector & frosted safety glass
- 304x/SD – with reÀector & semi frosted 100HS
- 304x/SP – with reÀector & printed / Dot 150HS

Mounting Surface wall mounted.

High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”. Photometrics & Dimensions
Control Gear High Frequency Electronic Control Gear “ECG”.
High Frequency Dimmable Electronic Control Gear “ECG”.

220v - 240v, 50 / 60Hz.


Voltage / Frequency 3042 70w HIE
“Other Voltages upon request”

Cable Entry 1x22 mm Ø hole on top. “Extra knock-out holes upon request”

3040/xx - 150 watt Incandescent GLS E27 – Max


120 watt PAR 38 E27 -- Max
100 watt QT-32 Quartz Tube E27 – Max
15, 20 & 23 watt EL Energy Saving E27
3041/xx - 13,18 & 26 watt TC-D/TC-T Compact Fluorescent for Normal Start “NS”, or TC-DE/TC-TE for
Electronic High Frequency “HF” Ballast “EB”.
32 & 42 watt TC-TE for Electronic High Frequency “HF” Ballast “EB”.
Lamps
50, 80 & 125 watt HME High Pressure Mercury Vapor E27,
70, 100 & 150 watt HIE/HIT Metal Halide E27.
50 & 70 watt HSE/HST High Pressure Sodium E27.
3042/xx –57 & 70 watt TC-TE for Electronic High Frequency “HF” Ballast “EB”.
250 watt HME High Pressure Mercury Vapor E40,
250 watt HIE/HIT Metal Halide E40.
100, 150 & 250 watt HSE/HST High Pressure Sodium E40.

Emergency Unit Applicable only for remote mounting (indoor) with CFL lamp version

264
Outdoor
Wall-Pack Floodlight

SMALL WALLPACK MEDIUM WALLPACK LARGE WALLPACK SYMMETRICAL ASYMMETRICAL SYMMETRICAL


FLOODLIGHT FLOODLIGHT FLOODLIGHT

SWP 272-273 MWP 274-275 LWP 276-277 FL206 296-297 FL208 298-299 FL400 300-301

Wall Mounted Tunnel Light

CYLINDRICAL SPHERICAL DIFFUSED RECESSED TUNNEL SURFACE TUNNEL


DIFFUSED LIGHTING LIGHTING LIGHT LIGHT

1004 278-279 2004 280-281 PTR 302-303 PTS 304-305

Wall Mounted Buried Uplight

CEILING ROUND CEILING SQUARE DRIVE-OVER LIGHT DRIVE-OVER LIGHT DRIVE-OVER LIGHT DRIVE-OVER LIGHT

CRM 282-283 CSM 284-285 607008 306-307 607009 308-309 GH98101 310-311 GH98108 312-313

Bollard Lighting Street Light

ROAD LIGHTING ROAD LIGHTING


LANDSCAPE LIGHTING LANDSCAPE LIGHTING LANDSCAPE LIGHTING LANDSCAPE LIGHTING

SL3 314-315 AR816 316-317

100 286-287 200 288-289 400 290-291 M-1005 292-293

Pole Lighting

LANDSCAPE LIGHTING

GL 294-295
Small Wallpack IP65
SERIES : SWP

Technical Data
To Order : follow the sequence mr - ln/ls - v/h - pf

Physical Characteristics

Frequency
Voltage

Accessories
Lamp
Reference

Size
Number

Control

Power
Factor
Model

/
Lamp

Gear
Type
L W H

watt V / Hz mm mm mm

50 HME-MBF

50 HSE-HST
CCG
(Ballast+Capacitor) LPF
Low
Power Factor

220 - 240V
70 HIE-HIT ------
SWP 1 175 280 133
50 / 60Hz HPF
High
CCG Power
(Ballast+Igniter+Capacitor) Factor
Suitable to be used in: lobbies, entrances, corridors, circulation areas, stairs, governmental premises, fence 70 HSE-HST
Applications
walls, general application for indoor and outdoor lighting, ...
Made of heavy duty die-cast aluminum, face frame is hinged and secured to the back box with two stainless
steel screws.
A silicone gasket provides weather-seal.
Housing 80 HME-MBF
All metal parts pre-treated with a full degreasing and phosphate process,
painted in stove enameled bronze baked epoxy polyester mix-powder.
“Other color ¿nishes upon request”
Anodized pure aluminum reÀector.
Light Controller Bowl of clear polycarbonate diffuser with ribbed lines,
Special rubber gasket for high protection.

Mounting Surface wall mounted.


Photometrics & Dimensions
Control Gear High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.

SWP 1/70w HST


220v - 240v, 50 / 60Hz.
Voltage / Frequency
“Other Voltages upon request”

Cable Entry 1x22 mm Ø hole on back-side.

50, 80 & 125 watt HME High Pressure Mercury Vapor E27,
Lamps 70 & 100 watt HIE/HIT Metal Halide E27.
50 & 70 watt HSE/HST High Pressure Sodium E27.

272
Medium Wallpack IP65
SERIES : MWP

Technical Data
To Order : follow the sequence mr - ln/ls - v/h - pf - acc

Physical Characteristics

Frequency
Voltage

Accessories
Lamp
Reference

Size

Optional
Number

Control

Power
Factor
Model

/
Lamp

Gear
Type
L W H

watt V / Hz mm mm mm

50 HME

50 HSE-HST

70 HIE-HIT
CCG
70 HSE-HST (Ballast+Capacitor) LPF
Low
80 HME Power Factor

100 HIE-HIT 220 - 240V


WG
MWP 1 367 236 181
Wire Guard
100 HSE-HST 50 / 60Hz HPF
High
125 HME CCG Power
(Ballast+Igniter+Capacitor) Factor
150 HIE-HIT
Suitable to be used in: lobbies, entrances, corridors, circulation areas, stairs, governmental premises, fence 150 HSE-HST
Applications
walls, general application for indoor and outdoor lighting, ...
175 HME
Made of heavy duty die-cast aluminum, face frame is hinged and secured to the back box with two stainless
steel screws. ½” tapped hole for securing conduit and installing a photocell 175 HIE
(photocell are optional)
Housing
A silicone gasket provides weather-seal. all metal parts pre-treated with a full degreasing and phosphate
process, painted in stove enameled bronze baked epoxy polyester mix-powder.
“Other color ¿nishes upon request”
Anodized pure aluminum reÀector.
Bowl of high impact and heat resistant Borosilicate glass diffuser ,
Light Controller
for wide spread distribution.
Special rubber gasket for high protection.

Mounting Surface wall mounted. Photometrics & Dimensions

Control Gear High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.
MWP 1/150w HIT

220v - 240v, 50 / 60Hz.


Voltage / Frequency
“Other Voltages upon request”

Cable Entry 1x22 mm Ø hole on back-side.

50, 80 & 125 watt HME High Pressure Mercury Vapor E27,
70, 100 & 150 watt HIE/HIT Metal Halide E27.
Lamps
50 & 70 watt HSE/HST High Pressure Sodium E27.
150 watt HSE/HST High Pressure Sodium E40

274
Large Wallpack IP65
SERIES : LWP

Technical Data
To Order : follow the sequence mr - ln/ls - v/h - pf - acc
Physical Characteristics

Frequency
Voltage

Accessories
Lamp
Reference

Size

Optional
Number

Control

Power
Factor
Model

/
Lamp

Gear
Type
L W H

watt V / Hz mm mm mm

50 HME

50 HSE-HST

70 HIE-HIT

70 HSE-HST

80 HME CCG
LPF
(Ballast+Capacitor)
Low
100 HIE-HIT
Power
Factor
100 HSE-HST
220 - 240V
WG
LWP 1 125 HME 456 250 238
Wire Guard
50 / 60Hz
HPF
150 HIE-HIT
High
CCG
Power
150 HSE-HST (Ballast+Igniter+Capacitor)
Factor
175 HME
Suitable to be used in: lobbies, entrances, corridors, circulation areas, stairs, governmental premises, fence
Applications
walls, general application for indoor and outdoor lighting, ... 175 HIE
Made of heavy duty die-cast aluminum, face frame is hinged and secured to the back box with two stainless 250 HME
steel screws. ½” tapped hole for securing conduit and installing a photocell
(photocell are optional) 250 HIE-HIT
Housing
A silicone gasket provides weather-seal. all metal parts pre-treated with a full degreasing and phosphate
process, painted in stove enameled bronze baked epoxy polyester mix-powder. 250 HSE-HST
“Other color ¿nishes upon request”
Anodized pure aluminum reÀector.
Bowl of high impact and heat resistant Borosilicate glass diffuser ,
Light Controller
for wide spread distribution.
Special rubber gasket for high protection.

Mounting Surface wall mounted. Photometrics & Dimensions

Control Gear High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.
LWP 1/250w HME

220v - 240v, 50 / 60Hz.


Voltage / Frequency
“Other Voltages upon request”

Cable Entry 1x22 mm Ø hole on back-side.

50, 80 & 125 watt HME High Pressure Mercury Vapor E27.
250 watt HME High Pressure Mercury Vapor E40.
70, 100 & 150 watt HIE/HIT Metal Halide E27.
Lamps
250 watt HIE/HIT Metal Halide E40.
50 & 70 watt HSE/HST High Pressure Sodium E27.
150 & 250 watt HSE/HST High Pressure Sodium E40

276
Wall / Cylindrical Diffused Lighting IP55
SERIES : 1004

Technical Data
To Order : follow the sequence mr - ln/ls - v/h - pf

Physical Characteristics

Frequency
Voltage

Accessories
Lamp
Reference

Size
Number

Control

Power
Factor
Model

/
Lamp

Gear
Type
L W H

watt V / Hz mm mm mm

13D/T
NS
Normal
Start
18D/T
LPF
Low
Power Factor

220 - 240V
1004 1 ------ 260 300 150
60 GLS 50 / 60Hz HPF
High
75 GLS Power
Factor
100 GLS
Suitable to be used in: entrances, porches, fence walls, parking area, general application for landscape and
Applications 60 QT32 ------
outdoor lighting, ...
15 EL
Made of heavy duty aluminum.
A silicone gasket provides weather-seal. all metal parts pre-treated with a full degreasing and phosphate 20 EL
Housing
process,painted in stove enameled black baked epoxy polyester mix-powder.
“Other color ¿nishes upon request” 23 EL

Cylindrical lens made of crystal glass, concentrate the light horizontally. Special rubber gasket for high
Light Controller
protection.

Mounting Surface wall mounted.

Photometrics & Dimensions


Control Gear High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.

220v - 240v, 50 / 60Hz. 1004 1/100w GLS


Voltage / Frequency
“Other Voltages upon request”

Cable Entry 1x22 mm Ø hole on back-side of the ¿xing bracket.

60, 75 & 100 watt Incandescent lamp E27


Lamps
13 & 18 watt TC-D/TC-T Compact Fluorescent lamp

278
Spherical Diffused Lighting IP55
SERIES : 2004

Technical Data
To Order : follow the sequence mr - ln/ls - v/h - pf

Physical Characteristics

Frequency

Accessories
Voltage
Reference

Lamp
Size
Number

Control

Power
Factor
Model

Lamp

/
Gear
Type
L W H

watt V / Hz mm mm mm
60 GLS
75GLS
------ 200 270 250
15 EL

13D/T
18D/T
NS
60 GLS
Normal Start
75 GLS
100 GLS 200 270 300
60 QT32
15 EL
------ LPF
20EL
23EL Low
Power Factor
13D/T
18D/T 220 - 240V
2004 1 26D/T ------
60 GLS 50 / 60Hz HPF
75 GLS High
100 GLS NS Power
150 GLS Normal Start Factor
60 QT32
80 QT32
Suitable to be used in: entrances, porches, fence walls, parking area, general application for landscape and 100 QT32 ------ 250 370 400
Applications 15 EL
outdoor lighting, ... 20EL CCG
23EL (Ballast+Igniter+Capacitor)
Bracket made of Made of heavy duty aluminum. Globe -base made of polycarbonate. A silicone gasket 50 HME
provides weather-seal. all metal parts pre-treated with a full degreasing and phosphate process,painted in 50 HSE-HST
Housing
stove enameled black baked epoxy polyester mix powder. 70 HIE-HIT
“Other color ¿nishes upon request” 70 HSE-HST
80 HME
UV stabilized acrylic opal sphere. 125 HME
Special rubber gasket for high protection.
Light Controller - 2004/25 – Opal Globe 250 mm Dia.
- 2004/30 – Opal Globe 300 mm Dia.
- 2004/40 – Opal Globe 400 mm Dia.

Mounting Surface wall mounted.


Photometrics & Dimensions
Control Gear High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.
2004 1/70w HLE
220v - 240v, 50 / 60Hz.
Voltage / Frequency
“Other Voltages upon request”

Cable Entry 1x22 mm Ø hole on back-side of the ¿xing bracket.

- 2004/25 – 60 & 75 watt Incandescent lamp E27.


- 2004/30 – 100 watt Incandescent lamp E27,
13 & 18 watt TC-D/TC-T Compact Fluorescent lamp,
Lamps - 2004/40 -- 26 watt TC-D/TC-T Compact Fluorescent lamp,
50, 80 & 125 watt HME High Pressure Mercury Vapor E27,
70 watt HIE/HIT Metal Halide E27.
50 & 70 watt HSE/HST High Pressure Sodium E27.

280
Ceiling Round IP55
SERIES : CRM

Technical Data
To Order : follow the sequence mr - ln/ls - v/h - pf

Physical Characteristics

Frequency

Accessories
Voltage
Reference

Lamp
Size
Number

Control

Power
Factor
Model

Lamp

/
Gear
Type
L W H

watt V / Hz mm mm mm
60 GLS
75GLS
------ 200 270 250
15 EL

13D/T
18D/T
NS
60 GLS
Normal Start
75 GLS
100 GLS 200 270 300
60 QT32
15 EL
------ LPF
20EL
23EL Low
Power Factor
13D/T
18D/T 220 - 240V
CRM 1 26D/T ------
60 GLS 50 / 60Hz HPF
75 GLS High
100 GLS NS Power
150 GLS Normal Start Factor
60 QT32
80 QT32
Suitable to be used in: entrances, porches, fence walls, parking area, general application for landscape and 100 QT32 ------ 250 370 400
Applications 15 EL
outdoor lighting, ... 20EL CCG
23EL (Ballast+Igniter+Capacitor)
Made of heavy duty die-cast aluminum, round base with polycarbonate
50 HME
diffuser. A silicone gasket provides weather-seal. ½” tapped hole for installing photocell. 50 HSE-HST
(photocell are optional) 70 HIE-HIT
Housing
all metal parts pre-treated with a full degreasing and phosphate process, 70 HSE-HST
painted in stove enameled bronze baked epoxy polyester mix-powder. 80 HME
“Other color ¿nishes upon request” 125 HME

Anodized pure aluminum reÀector.


Light Controller Bowl of prismatic polycarbonate round diffuser UV stabilized,
Special rubber gasket for high protection.

Mounting Surface wall / ceiling mounted.


Photometrics & Dimensions
Control Gear High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.

CRM 1/70w HIE


220v - 240v, 50 / 60Hz.
Voltage / Frequency
“Other Voltages upon request”

Cable Entry 1x22 mm Ø hole on back-side.

13,18 & 26 watt TC-D/TC-T Compact Fluorescent for Normal Start “NS”,
or TC-DE/TC-TE for Electronic High Frequency “HF” Ballast “EB”.
32 & 42 watt TC-TE for Electronic High Frequency “HF” Ballast “EB”.
Lamps 50, 80 & 125 watt HME High Pressure Mercury Vapor E27,
70, 100 & 150 watt HIE/HIT Metal Halide E27.
50 & 70 watt HSE/HST High Pressure Sodium E27.
150 watt HSE/HST High Pressure Sodium E40
3 Hours duration Emergency Unit “EMU” with battery pack Maintained “/M” or Non-Maintained “/NM” for one
Emergency Unit CF lamp, and for various lamps types and voltage networks combinations.
“Additional Emergency Units to operate more than one lamp on request”

282
Ceiling Square IP65
SERIES : CSM

Technical Data
To Order : follow the sequence mr - ln/ls - v/h - pf

Physical Characteristics

Frequency

Accessories
Voltage
Reference

Lamp
Size
Number

Control

Power
Factor
Model

Lamp

/
Gear
Type
L W H

watt V / Hz mm mm mm
60 GLS
75GLS
------ 200 270 250
15 EL

13D/T
18D/T
NS
60 GLS
Normal Start
75 GLS
100 GLS 200 270 300
60 QT32
15 EL
------ LPF
20EL
23EL Low
Power Factor
13D/T
18D/T 220 - 240V
CSM 1 26D/T ------
60 GLS 50 / 60Hz HPF
75 GLS High
100 GLS NS Power
150 GLS Normal Start Factor
60 QT32
80 QT32
Suitable to be used in: entrances, porches, fence walls, parking area, general application for landscape and 100 QT32 ------ 250 370 400
Applications 15 EL
outdoor lighting, ... 20EL CCG
23EL (Ballast+Igniter+Capacitor)
Made of heavy duty die-cast aluminum, round base with polycarbonate
50 HME
diffuser. A silicone gasket provides weather-seal. ½” tapped hole for installing photocell. 50 HSE-HST
(photocell are optional) 70 HIE-HIT
Housing
all metal parts pre-treated with a full degreasing and phosphate process, 70 HSE-HST
painted in stove enameled bronze baked epoxy polyester mix-powder. 80 HME
“Other color ¿nishes upon request” 125 HME

Anodized pure aluminum reÀector.


Light Controller Bowl of prismatic polycarbonate round diffuser UV stabilized,
Special rubber gasket for high protection.

Mounting Surface wall / ceiling mounted.


Photometrics & Dimensions
Control Gear High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.

CSM 1/70w HIE


220v - 240v, 50 / 60Hz.
Voltage / Frequency
“Other Voltages upon request”

Cable Entry 1x22 mm Ø hole on back-side.

13,18 & 26 watt TC-D/TC-T Compact Fluorescent for Normal Start “NS”,
or TC-DE/TC-TE for Electronic High Frequency “HF” Ballast “EB”.
32 & 42 watt TC-TE for Electronic High Frequency “HF” Ballast “EB”.
Lamps 50, 80 & 125 watt HME High Pressure Mercury Vapor E27,
70, 100 & 150 watt HIE/HIT Metal Halide E27.
50 & 70 watt HSE/HST High Pressure Sodium E27.
150 watt HSE/HST High Pressure Sodium E40
3 Hours duration Emergency Unit “EMU” with battery pack Maintained “/M” or Non-Maintained “/NM” for one
Emergency Unit CF lamp, and for various lamps types and voltage networks combinations.
“Additional Emergency Units to operate more than one lamp on request”

284
Landscape Lighting IP55
SERIES : 100

Technical Data
To Order : follow the sequence mr s/at - ln/ls - v/h - pf

Physical Characteristics

Frequency
Voltage

Accessories
Lamp
Reference

Size
Number

Control

Power
Factor
Model

/
Lamp

Gear
Type
Size
L W H

watt V / Hz mm mm mm

13D/T
1 1200

18D/T

60 GLS
LPF
NS
Low
Normal Start
75 GLS Power Factor
2 220 - 240V 800
100 1 100 GLS ------ -- 150
50 / 60Hz HPF
High
60 QT32 Power
Factor
------
Suitable to be used in: porches, gardens & general application for landscape and outdoor lighting, ... 15 EL
Applications

Made of heavy duty aluminum. 20EL


3 500
A silicone gasket provides weather-seal.
Housing Stainless steel ¿xing screws. all metal parts pre-treated with a full degreasing and phosphate process, painted
23EL
in stove enameled black baked epoxy polyester mix powder.
“Other color ¿nishes upon request”

Cylindrical lens made of crystal glass, concentrate the light horizontally


Light Controller
Special rubber gasket for high protection.

- 1001 -- Surface bollard 1200 mm height.


Mounting - 1002 – Surface bollard 800 mm height.
- 1003 – Fence-Top surface pillar 500 mm height.
Photometrics & Dimensions
Control Gear High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.

1001 1/100W GLS


220v - 240v, 50 / 60Hz.
Voltage / Frequency
“Other Voltages upon request”

Cable Entry 1x50 mm Ø hole on back-side of the ¿xing ground plate.

13,18 & 26 watt TC-D/TC-T Compact Fluorescent for Normal Start “NS”,
Lamps
Energy saving EL version E 27

286
Landscape Lighting IP55
SERIES : 200

Technical Data
To Order : follow the sequence mr s - ln/ls - v/h - pf

Physical Characteristics

Frequency
Voltage

Accessories
Lamp
Reference

Size
Number

Control

Power
Factor
Model

/
Lamp

Gear
Type
Size
L W H

watt V / Hz mm mm mm

250

13D/T
1 18D/T 1000 300
26D/T
NS
60 GLS 400
Normal Start
75 GLS
100 GLS LPF
150 GLS Low
Power Factor 250
60 QT32
80 QT32 220 - 240V
2 ------ 500 300
200 1 100 QT32 ------ --
50 / 60Hz HPF
15 EL High
20EL Power 400
23EL Factor
CCG
50 HME
Applications Suitable to be used in: porches, gardens & general application for landscape and outdoor lighting, ... (Ballast+Igniter+Capacitor) 250
50 HSE-HST
70 HIE-HIT
Made of heavy duty aluminum. 70 HSE-HST
A silicone gasket provides weather-seal. 3 80 HME 250 300
125 HME
Housing Stainless steel ¿xing screws. all metal parts pre-treated with a full degreasing and phosphate process, painted
in stove enameled black baked epoxy polyester mix powder.
“Other color ¿nishes upon request” 400

UV stabilized acrylic opal sphere.


Special rubber gasket for high protection.
Light Controller - 200x/25 – Opal Globe 250 mm Dia.
- 200x/30 – Opal Globe 300 mm Dia.
- 200x/40 – Opal Globe 400 mm Dia.
- 2001/xx -- Surface bollard 1000 mm height.
- 2002/xx – Surface bollard 500 mm height.
Photometrics & Dimensions
Mounting
- 2003/xx – Fence-Top surface pillar 250 mm height.
- 2003/40 -- Fence-Top surface pillar 390 mm height

2001 1/100w GLS


Control Gear High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.

220v - 240v, 50 / 60Hz.


Voltage / Frequency
“Other Voltages upon request”

Cable Entry 1x50 mm Ø hole on back-side of the ¿xing ground plate.

- 200x/25 – 60 & 75 watt Incandescent lamp E27.


- 200x/30 – 100 watt Incandescent lamp E27,
13 & 18 watt TC-D/TC-T Compact Fluorescent lamp,
Lamps - 200x/40 -- 26 watt TC-D/TC-T Compact Fluorescent lamp,
50, 80 & 125 watt HME High Pressure Mercury Vapor E27,
70 watt HIE/HIT Metal Halide E27.
50 & 70 watt HSE/HST High Pressure Sodium E27.

288
Landscape Lighting IP55
SERIES : 400

Technical Data
To Order : follow the sequence mr s - ln/ls - v/h
Physical Characteristics

Frequency
Voltage

Accessories
Lamp
Reference

Size
Number

Control

Power
Factor
Model

/
Lamp

Gear
Type
Size
L W H

watt V / Hz mm mm mm

1 430

60 GLS

75 GLS

2 750
100 GLS

220 - 240V
400 1 60 QT32 ------ ------ ------ -- 150
50 / 60Hz

15 EL
3 1000

20EL
Applications Suitable to be used in: porches, gardens & general application for landscape and outdoor lighting, ...
23EL
Made of heavy duty aluminum.
A silicone gasket provides weather-seal.
Housing Stainless steel ¿xing screws. all metal parts pre-treated with a full degreasing and phosphate process, painted 4 1230
in stove enameled black baked epoxy polyester mix powder.
“Other color ¿nishes upon request”

One piece extrusion in impact resistant PC UV stabilized polycarbonate with a smooth surface.
Light Controller
Special rubber gasket for high protection.

- 4001 -- Fence-Top surface pillar 450 mm height.


- 4002 – Surface bollard 750 mm height.
Mounting
- 4003 – Surface bollard 1000 mm height.
- 4004 -- Surface bollard 1230 mm height.
Photometrics & Dimensions
120v, 127v, 220v or 277v / 60Hz.
Control Gear
220v, 230v or 240v / 50Hz. 4001 1/60w GLS

220v - 240v, 50 / 60Hz.


Voltage / Frequency
“Other Voltages upon request”

Cable Entry 1x50 mm Ø hole on back-side of the ¿xing ground plate.

60, 75 & 100 watt Incandescent lamp E27


Lamps
15 & 20 watt EL Energy Saving Compact Fluorescent lamp E27

290
Landscape Lighting IP55
SERIES : 1005

Technical Data
To Order : follow the sequence mr - ln/ls - v/h

Physical Characteristics

Frequency
Voltage

Accessories
Lamp
Reference

Size
Number

Control

Power
Factor
Model

/
Lamp

Gear
Type
L W H

watt V / Hz mm mm mm

13D/T
18D/T
26D/T

60 GLS
NS
75 GLS
Normal Start
100 GLS
150 GLS LPF
Low
60 QT32 Power Factor
80 QT32
100 QT32 220 - 240V
------
1005 1 ------ 1200 -- 200
15 EL 50 / 60Hz HPF
20EL High
23EL Power
Factor
50 HME
CCG
50 HSE-
(Ballast+Igniter+Capacitor)
Applications Suitable to be used in: porches, gardens & general application for landscape and outdoor lighting, ... HST
70 HIE-HIT
70 HSE-
Made of heavy duty aluminum. Top section made of die-cast aluminum.A silicone gasket provides weather- HST
seal. Stainless steel ¿xing screws. all metal parts pre-treated with a full degreasing and phosphate process, 80 HME
Housing
painted in stove enameled black matt-baked epoxy polyester mix-powder. 125 HME
“Other color ¿nishes upon request”

Light Controller Cylindrical lens made of matt stepped crystal glass.

Mounting Surface bollard 1200 mm height.

Photometrics & Dimensions


Control Gear High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.

220v - 240v, 50 / 60Hz. 1005 1/18w TC-D


Voltage / Frequency
“Other Voltages upon request”

Cable Entry 1x50 mm Ø hole on back-side of the ¿xing ground plate.

60, 75 & 100 watt Incandescent lamp E27.


15 & 20 watt EL Energy Saving Compact Fluorescent lamp E27
13, 18 & 26 watt TC-D/TC-T Compact Fluorescent lamp.
Lamps
50, 80 & 125 watt HME High Pressure Mercury Vapor E27,
70 watt HIE/HIT Metal Halide E27.
50 & 70 watt HSE/HST High Pressure Sodium E27.

292
Landscape Lighting IP55
SERIES : GL

Technical Data
To Order : follow the sequence mr s - ln/ls - v/h - pf
Physical Characteristics

Frequency
Voltage

Accessories
Lamp
Reference

Size
Number

Control

Power
Factor
Model

/
Lamp

Gear
Type
Size
L W H

watt V / Hz mm mm mm

60 GLS
25 75 GLS 250
15 EL
13D/T
18D/T
60 GLS
75 GLS
100 GLS
30 300
60 QT32 NS
80 QT32 Normal Start
15 EL
LPF
20EL
Low
23EL
Power Factor
13D/T
18D/T 220 - 240V
------
GL 1 26D/T ------ -- --
60 GLS 50 / 60Hz HPF
75 GLS High
100 GLS Power
150 GLS Factor
60 QT32 CCG
80 QT32 (Ballast+Igniter+Capacitor)
Suitable to be used in: car parks, footpaths, pedestrian precincts, parks and gardens, entrances to buildings, 40 100 QT32 400
Applications
porches, building perimeters, general application for landscape and outdoor lighting, ... 15 EL
20EL
Globe-base made of polycarbonate, 23EL
Pole with bracket made of aluminum or galvanized steel “ upon request “. 50 HME
A silicone gasket provides weather-seal. 50 HSE-HST
Housing 70 HIE-HIT
all metal parts pre-treated with a full degreasing and phosphate process,
painted in stove enameled black baked epoxy polyester mix-powder. 70 HSE-HST
“Other color ¿nishes upon request” 80 HME
125 HME
UV stabilized acrylic opal sphere.
Special rubber gasket for high protection.
Light Controller - GL/25 – Opal Globe 250 mm Dia.
- GL/30 – Opal Globe 300 mm Dia.
- GL/40 – Opal Globe 400 mm Dia.
Photometrics & Dimensions
Mounting Surface; pole mounted.

Control Gear High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”. GL40 1/125w HME

220v - 240v, 50 / 60Hz.


Voltage / Frequency
“Other Voltages upon request”

Cable Entry 1x50 mm Ø hole on back-side of the ¿xing ground plate.

- GL/25 – 60 & 75 watt Incandescent lamp E27.


- GL/30 – 100 watt Incandescent lamp E27,
13 & 18 watt TC-D/TC-T Compact Fluorescent lamp,
Lamps - GL/40 -- 26 watt TC-D/TC-T Compact Fluorescent lamp,
50, 80 & 125 watt HME High Pressure Mercury Vapor E27,
70 watt HIE/HIT Metal Halide E27.
50 & 70 watt HSE/HST High Pressure Sodium E27.

Note POLES TO BE ORDERED SEPARATLEY

294
Landscape Lighting IP65
SERIES : FL206

Technical Data
To Order : follow the sequence mr - ln/ls - v/h - pf
Physical Characteristics

Frequency

Accessories
Voltage
Reference

Lamp
Size
Number

Control

Power
Factor
Model

Lamp

/
Gear
Type
L W H

watt V / Hz mm mm mm
50 HME

50 HSE-HST

70 HIE-HIT

70 HSE-HST

80 HME

100 HIE-HIT CCG


(Ballast+Capacitor) LPF
100 HSE-HST Low
Power Factor
125 HME
220 - 240V
------
FL206 1 150 HIE-HIT 377 227 282
50 / 60Hz HPF
150 HSE-HST High
CCG Power
175 HME (Ballast+Igniter+Capacitor) Factor

175 HIE
Suitable to be used in: building façade, landscape lighting, sign lighting, display, fence and perimeter lighting,
Applications 250 HME
general safety and security lighting, ...
Durable die-cast aluminum housing construction. 250 HIE-HIT
Die-cast aluminum door frame retains clear tempered glass.
250 HSE-HST
A silicone gasket provides weather-seal.
Housing
all metal parts pre-treated with a full degreasing and phosphate process, 400 HIE-HIT
painted in stove enameled black or bronze baked epoxy polyester mix-powder.
“Other color ¿nishes upon request” 400 HSE-HST

Symmetric specular aluminum reÀector.


Light Controller
Clear tempered glass

Mounting Surface; pole mounted.


Photometrics & Dimensions
Control Gear High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.

FL206 1/400w HST


220v - 240v, 50 / 60Hz.
Voltage / Frequency
“Other Voltages upon request”

Cable Entry 1x22 mm Ø hole.

70, 100 & 150 watt HIT Metal Halide lamp E27.
250 watt HIT Metal Halide lamp E40.
Lamps
50 & 70 watt HIT High Pressure Sodium Vapor lamp E27.
150 & 250 watt HIT High Pressure Sodium Vapor lamp E40

296
Asymmetrical Floodlight IP65
SERIES : FL208

Technical Data
To Order : follow the sequence mr - ln/ls - v/h - pf - acc

Physical Characteristics

Frequency
Voltage

Accessories
Lamp
Reference

Size
Number

Control

Power
Factor
Model

/
Lamp

Gear
Type
L W H

watt V / Hz mm mm mm

70 HIT-DE

LPF
Low
Power Factor
70 HST-DE
CCG
220 - 240V
(Ballast+Igniter+Capacitor) ------
FL208 1 245 355 85
50 / 60Hz HPF
High
150 HIT-DE
Power
Factor

Suitable to be used in: building façade, landscape lighting, sign lighting, display, fence and perimeter lighting,
Applications
general safety and security lighting, ...
150 HST-DE
Durable die-cast aluminum housing construction.
Die-cast aluminum door frame retains clear tempered glass.
A silicone gasket provides weather-seal.
Housing
all metal parts pre-treated with a full degreasing and phosphate process,
painted in stove enameled black or bronze baked epoxy polyester mix-powder.
“Other color ¿nishes upon request”

High quality asymmetric aluminum reÀector


Light Controller
Clear tempered glass.

Mounting Surface; pole mounted.


Photometrics & Dimensions
Control Gear High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.

FL208 1/150w HST-DE


220v - 240v, 50 / 60Hz.
Voltage / Frequency
“Other Voltages upon request”

Cable Entry 1x22 mm Ø hole.

70 watt RX7s HIT-DE/HST-DE Double-Ended Metal Halide or


High Pressure Sodium Vapor lamp
Lamps
150 watt RX7s-24 HIT-DE/HST-DE Double-Ended Metal Halide or
High Pressure Sodium Vapor lamp

298
Symmetrical Floodlight IP65
SERIES : FL400

Technical Data
To Order : follow the sequence mr - ln/ls - v/h - pf

Physical Characteristics

Frequency
Voltage

Accessories
Lamp
Reference

Size
Number

Control

Power
Factor
Model

/
Lamp

Gear
Type
L W H

watt V / Hz mm mm mm

50 HME
50 HSE-HST
70 HIE-HIT

70 HSE-HST
80 HME

100 HIE-HIT
CCG
100 HSE-HST (Ballast+Capacitor) LPF
Low
125 HME Power Factor
150 HIE-HIT 220 - 240V
------
FL400 1 414 294 165
150 HSE-HST 50 / 60Hz HPF
High
175 HME CCG Power
(Ballast+Igniter+Capacitor) Factor
175 HIE

250 HME
Applications Suitable to be used in: porches, gardens & general application for landscape and outdoor lighting, ...
250 HIE-HIT

Made of heavy duty aluminum. 250 HSE-HST


A silicone gasket provides weather-seal. 400 HME
Stainless steel ¿xing screws. all metal parts pre-treated with a full degreasing and phosphate process,
Housing
painted in stove enameled black baked epoxy polyester mix-powder. 400 HIE-HIT

400 HSE-HST
“Other color ¿nishes upon request”

One piece extrusion in impact resistant PC UV stabilized polycarbonate with a smooth surface.
Light Controller
Special rubber gasket for high protection.

Mounting surface or trunnion bracket mounted


Photometrics & Dimensions
Control Gear High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.

FL400 1/400w HIE


220v - 240v, 50 / 60Hz.
Voltage / Frequency
“Other Voltages upon request”

Cable Entry 1x50 mm Ø hole on back-side of the ¿xing ground plate.

60, 75 & 100 watt Incandescent lamp E27


Lamps
15 & 20 watt EL Energy Saving Compact Fluorescent lamp E27

300
Recessed Tunnel Light IP65
SERIES : PTR

Technical Data
To Order : follow the sequence mr/r - ln/ls - v/h - pf
Physical Characteristics

Frequency
Voltage

Accessories
Lamp
Reference

Reference

Size
Number

Control

Power
Factor
Model

Model

/
Lamp

Gear
Type
L W H

watt V / Hz mm mm mm

50 HME

50 HSE-HST
70 HIE-HIT
S
(Symmetric) 70 HSE-HST
80 HME
CCG
100 HIE-HIT (Ballast
+Capacitor) LPF
100 HSE-HST Low
125 HME Power Factor

150 HIE-HIT 220 - 240V


PTR 1 ------ 565 425 164
150 HSE-HST 50 / 60Hz HPF
High
175 HME CCG Power
175 HIE (Ballast Factor
+Igniter+Capacitor)
A 250 HME
Applications Suitable to be used in: of¿ces, clinics, education premises, circulation area & general indoor application. (Asymmetric)
250 HIE-HIT
Made of press welded Cold Rolled Steel “CRS” sheet of tight construction to prevent light leakage, all metal 250 HSE-HST
parts pre-treated with a full degreasing and phosphate process, painted in stove enameled white baked
Housing epoxy polyester mix-powder to ensure high reÀectance of painted surfaces. 400 HME
400 HIE-HIT
“Other color ¿nishes upon request”
400 HSE-HST
- PTR/S – Symmetric specular aluminum reÀector.
Light Controller - PTR/A – Asymmetric specular aluminum reÀector.
Clear tempered glass diffuser.

Mounting Recessed, concealed in the false ceiling.

High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.


Photometrics & Dimensions
Control Gear
High Frequency Electronic Control Gear “ECG”.

PTR 1/400w HIE


220v - 240v, 50 / 60Hz.
Voltage / Frequency
“Other Voltages upon request”

1x22 mm Ø hole on top.


Cable Entry
“Extra knock-out holes upon request”
50, 80 & 125 High Pressure Mercury Vapor lamp E27.
250 & 400 watt High Pressure Mercury Vapor lamp E40.
70, 100 &150 watt HIT Metal Halide lamp E27.
Lamps
250 & 400 watt HIT Metal Halide lamp E40.
50 & 70 watt HIT High Pressure Sodium Vapor lamp E27.
150, 250, 400 & 600 watt HIT High Pressure Sodium Vapor lamp E40

Accessories Steel safety grill painted upon request.

302
Surface Tunnel Light IP65
SERIES : PTS

Technical Data
To Order : follow the sequence mr/r - ln/ls - v/h - pf

Physical Characteristics

Frequency
Voltage

Accessories
Lamp
Reference

Reference

Size
Number

Control

Power
Factor
Model

Model

/
Lamp

Gear
Type
L W H

watt V / Hz mm mm mm

50 HME

50 HSE-HST
70 HIE-HIT

70 HSE-HST
S
(Symmetric) 80 HME
CCG
100 HIE-HIT (Ballast
LPF
+Capacitor)
100 HSE-HST Low
Power
125 HME Factor
150 HIE-HIT 220 - 240V
PTS 1 ------ 500 360 173
150 HSE-HST 50 / 60Hz
HPF
175 HME High
CCG
Power
175 HIE (Ballast
Factor
+Igniter+Capacitor)
Applications Suitable to be used in: of¿ces, clinics, education premises, circulation area & general indoor application. 250 HME
A 250 HIE-HIT
Made of press welded Cold Rolled Steel “CRS” sheet of tight construction to prevent light leakage, all metal (Asymmetric)
parts pre-treated with a full degreasing and phosphate process, painted in stove enameled white baked 250 HSE-HST
Housing epoxy polyester mix-powder to ensure high reÀectance of painted surfaces. 400 HME

“Other color ¿nishes upon request” 400 HIE-HIT

- PTS/S – Symmetric specular aluminum reÀector. 400 HSE-HST


Light Controller - PTS/A – Asymmetric specular aluminum reÀector.
Clear tempered glass diffuser.

Mounting

High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.


Photometrics & Dimensions
Control Gear
High Frequency Electronic Control Gear “ECG”.

PTS 1/250w HSE


220v - 240v, 50 / 60Hz.
Voltage / Frequency
“Other Voltages upon request”

1x22 mm Ø hole on top.


Cable Entry
“Extra knock-out holes upon request”
50, 80 & 125 High Pressure Mercury Vapor lamp E27.
250 & 400 watt High Pressure Mercury Vapor lamp E40.
70, 100 &150 watt HIT Metal Halide lamp E27.
Lamps
250 & 400 watt HIT Metal Halide lamp E40.
50 & 70 watt HIT High Pressure Sodium Vapor lamp E27.
150, 250, 400 & 600 watt HIT High Pressure Sodium Vapor lamp E40

Accessories Steel safety grill painted upon request.

304
Drive-Over Light IP67
SERIES : 607008

Technical Data
To Order : follow the sequence mr - ln/ls - v/h - pf
Physical Characteristics

Frequency
Voltage

Accessories
Lamp
Reference

Size
Number

Control

Power
Factor
Model

/
Lamp

Gear
Type
L W H

watt V / Hz mm mm mm

LPF
Low
Power Factor
70 HIT-DE
CCG
220 - 240V
(Ballast+Igniter+Capacitor) ------
607008 1 213 -- 280
50 / 60Hz HPF
High
70 HST-DE
Power
Factor

Suitable to be used in: drive-over Àoodlight with sideward light distribution, can be embedded in gravel, lawns,
Àowerbeds, pathways and squares or in compacted non-combustible surfaces. Vehicles with pneumatic tires
Applications can drive over the luminaire if the installation in ground guarantees the required stability but the speed of the
vehicle must not exceed 20 km/h. The luminaire may not be used for traf¿c lanes where are subjected to
horizontal pressure from vehicles braking, accelerating and changing direction.
Made of die-cast aluminum (EN AB44100) housing (copper free)
with high corrosion resistant, stainless steel ¿xing screws.
A silicone gasket provides weather-seal, polycarbonate recessing kit,
Housing
all metal parts pre-treated with a full degreasing and phosphate process,
painted in stove enameled silver baked epoxy polyester mix-powder to
ensure high reÀectance of painted surfaces.

High quality symmetric aluminum reÀector.


Light Controller
Clear tempered glass.
Photometrics & Dimensions
Mounting In - ground recessed

607008 1/70w HID


Control Gear High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.

220v - 240v, 50 / 60Hz.


Voltage / Frequency
“Other Voltages upon request”

Cable Entry 1x22 mm Ø hole

70 watt RX7s HIT-DE/HST-DE Double-Ended Metal Halide or


Lamps
High Pressure Sodium Vapor lamp

306
Drive-Over Light IP67
SERIES : 607009

Technical Data
To Order : follow the sequence mr - ln/ls - v/h - pf

Physical Characteristics

Frequency
Voltage

Accessories
Lamp
Reference

Size
Number

Control

Power
Factor
Model

/
Lamp

Gear
Type
L W H

watt V / Hz mm mm mm

70 HIT-DE

LPF
Low
Power Factor
70 HST-DE
CCG
220 - 240V
(Ballast+Igniter+Capacitor) ------
607009 1 300 -- 355
50 / 60Hz HPF
High
150 HIT-DE
Power
Factor

Suitable to be used in: drive-over Àoodlight with sideward light distribution, can be embedded in gravel, lawns,
Àowerbeds, pathways and squares or in compacted non-combustible surfaces. Vehicles with pneumatic tires 150 HST-DE
Applications can drive over the luminaire if the installation in ground guarantees the required stability but the speed of the
vehicle must not exceed 20 km/h. The luminaire may not be used for traf¿c lanes where are subjected to
horizontal pressure from vehicles braking, accelerating and changing direction.
Made of die-cast aluminum (EN AB44100) housing (copper free)
with high corrosion resistant, stainless steel ¿xing screws.
A silicone gasket provides weather-seal, polycarbonate recessing kit,
Housing
all metal parts pre-treated with a full degreasing and phosphate process,
painted in stove enameled silver baked epoxy polyester mix-powder to
ensure high reÀectance of painted surfaces.

High quality asymmetric aluminum reÀector.


Light Controller
Clear tempered glass.
Photometrics & Dimensions
Mounting In - ground recessed

607009 1/150w HID


Control Gear High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.

220v - 240v, 50 / 60Hz.


Voltage / Frequency
“Other Voltages upon request”

Cable Entry 1x22 mm Ø hole

150 watt RX7s-24 HIT-DE/HST-DE Double-Ended Metal Halide or


Lamps
High Pressure Sodium Vapor lamp

308
Drive-Over Light IP67
SERIES : GH98101

Technical Data
To Order : follow the sequence mr - ln/ls - v/h

Physical Characteristics

Frequency
Voltage

Accessories
Lamp
Reference

Size
Number

Control

Power
Factor
Model

/
Lamp

Gear
Type
L W H

watt V / Hz mm mm mm

35 QR-CB51

220 - 240V
GH98101 1 ------ ------ ------ 175 -- 253
50 / 60Hz

50 QR-CB51
Suitable to be used in: drive-over Àoodlight with sideward light distribution, can be embedded in gravel, lawns,
Àowerbeds, pathways and squares or in compacted non-combustible surfaces. Vehicles with pneumatic tires
Applications can drive over the luminaire if the installation in ground guarantees the required stability but the speed of the
vehicle must not exceed 20 km/h. The luminaire may not be used for traf¿c lanes where are subjected to
horizontal pressure from vehicles braking, accelerating and changing direction.
Made of die-cast aluminum (EN AB44100) housing (copper free)
with high corrosion resistant, stainless steel ¿xing screws.
A silicone gasket provides weather-seal, polycarbonate recessing kit,
Housing
all metal parts pre-treated with a full degreasing and phosphate process,
painted in stove enameled silver baked epoxy polyester mix-powder to
ensure high reÀectance of painted surfaces.

High quality symmetric aluminum reÀector.


Light Controller
Clear tempered glass.
Photometrics & Dimensions
Mounting In - ground recessed

GH98101 1/35w QR-CB51


Control Gear High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.

220v - 240v, 50 / 60Hz.


Voltage / Frequency
“Other Voltages upon request”

Cable Entry 1x22 mm Ø hole

Lamps 35 & 50 watt QR-CB 51 Halogen lamp.

310
Drive-Over Light IP67
SERIES : GH98108

Technical Data
To Order : follow the sequence mr - ln/ls - v/h - pf

Physical Characteristics

Frequency
Voltage

Accessories
Lamp
Reference

Size
Number

Control

Power
Factor
Model

/
Lamp

Gear
Type
L W H

watt V / Hz mm mm mm

70 HIT-DE

LPF
Low
Power Factor
70 HST-DE
CCG
220 - 240V
(Ballast+Igniter+Capacitor) ------
GH98108 1 305 -- 260
50 / 60Hz HPF
High
150 HIT-DE
Power
Factor

Suitable to be used in: drive-over Àoodlight with sideward light distribution, can be embedded in gravel, lawns,
Àowerbeds, pathways and squares or in compacted non-combustible surfaces. Vehicles with pneumatic tires 150 HST-DE
Applications can drive over the luminaire if the installation in ground guarantees the required stability but the speed of the
vehicle must not exceed 20 km/h. The luminaire may not be used for traf¿c lanes where are subjected to
horizontal pressure from vehicles braking, accelerating and changing direction.
Made of die-cast aluminum (EN AB44100) housing (copper free)
with high corrosion resistant, stainless steel ¿xing screws.
A silicone gasket provides weather-seal, polycarbonate recessing kit,
Housing
all metal parts pre-treated with a full degreasing and phosphate process,
painted in stove enameled silver baked epoxy polyester mix-powder to
ensure high reÀectance of painted surfaces.

High quality symmetric aluminum reÀector.


Light Controller
Clear tempered glass.
Photometrics & Dimensions
Mounting In - ground recessed

GH98108 1/70w HIT-DE


Control Gear High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”.

220v - 240v, 50 / 60Hz.


Voltage / Frequency
“Other Voltages upon request”

Cable Entry 1x22 mm Ø hole

70 watt RX7s HIT-DE/HST-DE Double-Ended Metal Halide or


High Pressure Sodium Vapor lamp
Lamps
150 watt RX7s-24 HIT-DE/HST-DE Double-Ended Metal Halide or
High Pressure Sodium Vapor lamp

312
Road Lighting IP65
SERIES : SL3

Technical Data
To Order : follow the sequence mr - ln/ls - v/h - pf
Physical Characteristics

Frequency
Voltage

Accessories
Lamp
Reference

Size
Number

Control

Power
Factor
Model

/
Lamp

Gear
Type
L W H

watt V / Hz mm mm mm

50 HME

50 HSE-HST
70 HIE-HIT

70 HSE-HST
80 HME
100 HIE-HIT
CCG
100 HSE-HST (Ballast+Capacitor) LPF
Low
125 HME Power Factor

150 HIE-HIT 220 - 240V


------
SL3 1 749 356 280
150 HSE-HST 50 / 60Hz HPF
High
175 HME CCG Power
(Ballast+Igniter+Capacitor) Factor
175 HIE
250 HME
Applications Suitable to be used in: express roads, major roads, trunk, residential & local street ... 250 HIE-HIT

Rugged die-cast with aluminum housing construction. 250 HSE-HST


Hinged cover and bowl allowing maximum ease in installation 400 HME
and maintenance.
Hinged prismatic glass refractor bowl tempered and shockproof. 400 HIE-HIT
Housing
A silicone gasket provides weather-seal. 400 HSE-HST
all metal parts pre-treated with a full degreasing and phosphate process,
painted in stove enameled grey baked epoxy polyester mix-powder.
“Other color ¿nishes upon request”

High quality symmetric aluminum reÀector.


Light Controller
Prismatic glass refractor bowl tempered and shockproof.
Photometrics & Dimensions
Mounting Surface, aluminum or steel-galvanized pole-side mounted with arm bracket.

High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”. SL3 1/400w HSE
Control Gear
Ballast, Igniter and High Power Factor Capacitor.

220v - 240v, 50 / 60Hz.


Voltage / Frequency
“Other Voltages upon request”

Cable Entry 1x50 mm Ø hole.

50, 80 & 125 High Pressure Mercury Vapor lamp E27.


250 & 400 watt High Pressure Mercury Vapor lamp E40.
70, 100 &150 watt HIT Metal Halide lamp E27.
Lamps
250 & 400 watt HIT Metal Halide lamp E40.
50 & 70 watt HIT High Pressure Sodium Vapor lamp E27.
150, 250 & 400 watt HIT High Pressure Sodium Vapor lamp E40

314
Road Lighting IP55
SERIES : AR816

Technical Data
To Order : follow the sequence mr - ln/ls - v/h - pf

Physical Characteristics

Frequency
Voltage

Accessories
Lamp
Reference

Size
Number

Control

Power
Factor
Model

/
Lamp

Gear
Type
L W H

watt V / Hz mm mm mm

50 HME
50 HSE-HST
70 HIE-HIT
70 HSE-HST
80 HME
100 HIE-HIT CCG
(Ballast+Capacitor) LPF
100 HSE-HST Low
125 HME Power Factor

150 HIE-HIT 220 - 240V


AR816 1 ------ 430 420 170
150 HSE-HST 50 / 60Hz HPF
175 HME High
CCG Power
175 HIE (Ballast+Igniter+Capacitor) Factor
250 HME
Suitable to be used in: express roads, major roads, trunk, residential & local street, tennis, handball and
Applications 250 HIE-HIT
basketball courts ...
250 HSE-HST
Rugged die-cast with aluminum housing construction. 400 HME
Hinged cover and frame-diffuser allowing maximum ease in installation
and maintenance. 400 HIE-HIT
Hinged clear or frosted tempered glass. 400 HSE-HST
Housing
A silicone gasket provides weather-seal.
all metal parts pre-treated with a full degreasing and phosphate process,
painted in stove enameled black or bronze baked epoxy polyester mix-powder.
“Other color ¿nishes upon request”
High quality multi-faceted aluminum reÀector on cut-off designs
Light Controller for a no-glare unit
Clear or frosted tempered glass.
Photometrics & Dimensions
Mounting Surface, aluminum or steel-galvanized pole-side mounted with arm bracket.

High Power Factor “HPF” ( • 90 ) Conventional Control Gear “CCG”. AR816 1/250w HIE
Control Gear
Ballast, Igniter and High Power Factor Capacitor.

220v - 240v, 50 / 60Hz.


Voltage / Frequency
“Other Voltages upon request”

Cable Entry 1x(77x127) mm rectangular-hole.

50, 80 & 125 High Pressure Mercury Vapor lamp E27.


250 & 400 watt High Pressure Mercury Vapor lamp E40.
70, 100 &150 watt HIT Metal Halide lamp E27.
Lamps
250 & 400 watt HIT Metal Halide lamp E40.
50 & 70 watt HIT High Pressure Sodium Vapor lamp E27.
150, 250 & 400 watt HIT High Pressure Sodium Vapor lamp E40

316
W
A1
D E F I N I T I O N S Solid Angle

(Term of mathematics/geometry)
Quantities Symbol Units of measure Description Relations

Luminous flux Φ Lumen (lm) The quantity of light emitted by a light source The angle that, seen from the center of a sphere, includes a given area on the surface of that sphere. The
value of the solid angle is numerically equal to the size of that area divided by the square of the radius of
Luminous Intensity I Candela (cd) The luminous flux leaving a light source within an element
of solid angle divided by the solide angle Ω
the sphere.

Illuminance E Lux (lx) The luminous flux reaching a surface element divided by
the area A of that element

Luminance L Candela/m2 (cd/m2) For the surface of a source: ratio of the luminous intensity
of a source in the given direction (I) to the apparent surface
of a source seen from this direction.

Solid angle Ω Steradian (sr) Angular opening from the vertex to the optical centre of
the source, of the spherical sector within which light emission
is considered.

Light source efficiency μ Lumen/Watt (lm/w) This is the ratio of the luminous flux emitted by the lamp
to absorbed power.

Luminaire efficiency ε This is the ratio of the flux emitted by the luminaire and total flux
from light sources inside the luminaire.

O 2
Colour temperature K Kelvin It is the light shade that corresponds to the temperature =A/r
of a standardized reference body (Planckís black body).

Colour rendering factor Ra It indicates the capability of the source to restore the colored Other than the diagram might suggest, the shape of the area doesn't matter at all. Any shape on the
aspect of illuminated objects referenced to same temperature surface of the sphere that holds the same area will define a solid angle of the same size.
of standardized light source.

Utilisation factor U This is the ratio of the luminous flux reaching the working plane,
Also, the diagram only shows the elements that define a solid angle, not the solid angle itself. The solid
both directly and indirectly, to total flux emitted from the light angle is the quantitative aspect of the conical slice of space, that has the center of the sphere as its peak,
sources inside the luminaires.
the area on the surface of the sphere as one of its spherical cross sections, and extends to infinity.
Room index k This is the parameter that defines a room in function
of its width (a), length (b) and the distance ceiling The maximum solid angle is ~12.57, corresponding to the full area of the unit sphere, which is 4*Pi.
and working plane, (hu)

Standard unit of a solid angle is the Steradian (sr).


Reflection factor ρ This the ratio of the emitted flux to the incident flux (in %)
(Mathematically, the solid angle is unitless, but for practical reasons, the steradian is assigned.)
Maintenance factor M This is the ratio of the average illuminance picked
on the considered moment to the initial average illuminance.

Depreciation factor d This is the inverse ratio of maintenance factor.

Cut off angle Angle between the vertical and the first line where
the light source can be seen from a luminaire.

Shielding angle Complementary angle of the cut off angle .

Specular or brillant surface Surface which emits the reflected rays in a symmetrical
and regular manner versus the vertical direction
to the incident rays

Matt or diffuse surface Surface which emits the reflected rays in a scattered
and irregular way (different directions and intensity)
to the incident rays
A2 A3
E N C L O S U R E P R O T E C T I O N E N C L O S U R E P R O T E C T I O N

1st DIGIT PROTECTION AGAINST SOLIDS 2nd DIGIT PROTECTION AGAINSTS 3rd DIGIT RESISTANCE AGAINST 1st DIGIT PROTECTION AGAINST SOLIDS 2nd DIGIT PROTECTION AGAINSTS 3rd DIGIT RESISTANCE AGAINST
LIQUIDS & MOISTURE d MECHANICAL IMPACT LIQUIDS & MOISTURE d MECHANICAL IMPACT
Class Symbol Physical contact Foreign bodies Class Symbol Liquids & Moisture Class Class Symbol Physical contact Foreign bodies Class Symbol Liquids & Moisture Class

0 - - - 0 - - 0 - - - 0 - -
0 - 0 -
2 - by fingers medium size 2 drip-proof 2 - by fingers medium size 2 drip-proof
1 0.225 N x m 1 0.225 N x m
3 - by tools foreign bodies 3 rain proof 3 - by tools foreign bodies 3 rain proof
< 2.5mm 3 0,500 Nxm < 2.5mm 3 0,500 Nxm
4 splash-proof 4 splash-proof
4 - by wires foreign bodies 5 2,000 N x m 4 - by wires foreign bodies 5 2,000 N x m
<1mm 5 jet-water proof <1mm 5 jet-water proof
7 6,000 N x m 7 6,000 N x m
5 fully protected dustproof no 5 fully protected dustproof no
7 water-tight 7 water-tight
harmful deposits 9 20,000 N x m harmful deposits 9 20,000 N x m
vandal-proof vandal-proof
6 highly Protected dust-tight 6 highly Protected dust-tight

E L E C T R I C A L P R O T E C T I O N E L E C T R I C A L P R O T E C T I O N

Luminaires are divided into 3 protection classes Class Symbol Definition Luminaires are divided into 3 protection classes Class Symbol Definition
according to the various protective measures according to the various protective measures
taken against the danger of electrical shock. I Luminaires to be connected to an earthing lead taken against the danger of electrical shock. I Luminaires to be connected to an earthing lead
All our luminaires are constructed and tested All our luminaires are constructed and tested
according to international recommendations II Luminaires Insulated and not requiring earthing according to international recommendations II Luminaires Insulated and not requiring earthing
and thus conform to nearly all national regulations. and thus conform to nearly all national regulations.
III Luminaires built exclusively for operation on safety extra- III Luminaires built exclusively for operation on safety extra-
low voltage (not exceeding 42 V between conductors, low voltage (not exceeding 42 V between conductors,
therefore not for discharge lamps). therefore not for discharge lamps).

F I R E R E S I S TA N C E F I R E R E S I S TA N C E

Class Definition Class Definition


M0 Not Combustible M0 Not Combustible
M1 Not Flammable M1 Not Flammable
M2 Hardly Flammable M2 Hardly Flammable
M3 Flammable I M3 Flammable I
M4 Easily Flammable M4 Easily Flammable
M5 Highly Flammable M5 Highly Flammable
A4 A5
IMPACT PROTECTION (IK) RATING M I N I M U M R E Q U I R E M E N T S F O R L I G H T I N G

Room purpose or work involved Rated illuminance (lux) Fluorescent lamp Remarks
colour designation colour index

General Areas
Traffic areas for personnel in buildings:
Degrees of protection provided by enclosures for electrical equipment against external stairs, corridors, entrances 80 . . . . . . . . . . . .nw or ww . . . . . . . . . . .1 or 2 For stairs avoid shadows and glare
mechanical impacts in accordance with IEC 62262:2002 and IEC 60068-2-75:1997. Garages, car parks, loading bays... 60 . . . . . . . . . . . .nw or ww . . . . . . . . . . . .3
Dressing rooms, washrooms, toilets... 100 . . . . . . . . . . . .nw or ww . . . . . . . . . . .1 or 2 ww over mirror
IK00 Not protected
Administration rooms and offices
IK01 Protected against 0.14 joules impact. a- Office areas
Equivalent to impact of 0.25kg mass dropped from 56mm above impacted surface. General office 500 . . . . . . . . . . . .nw or ww . . . . . . . . . . .1 or 2
Computer work stations 300-500 . . . . . . . . . .nw or ww . . . . . . . . . . .1 or 2
IK02 Protected against 0.2 joules impact. Conference rooms, executive offices 500 . . . . . . . . . . . .nw or ww . . . . . . . . . . .1 or 2
Equivalent to impact of 0.25kg mass dropped from 80mm above impacted surface. Computer and data preparation rooms 500 . . . . . . . . . . . .nw or ww . . . . . . . . . . .1 or 2
Filing rooms 300 . . . . . . . . . . . .nw or ww . . . . . . . . . . .1 or 2
IK03 Protected against 0.35 joules impact. b- Drawing Offices
Equivalent to impact of 0.25kg mass dropped from 140mm above impacted surface. General 500 . . . . . . . . . . . .nw or ww . . . . . . . . . . .1 or 2
Drawing Boards 750 . . . . . . . . . . . .nw or ww . . . . . . . . . . .1 or 2
IK04 Protected against 0.5 joules impact. Computer aided design and drafting 300-500 . . . . . . . . . .nw or ww . . . . . . . . . . .1 or 2
Equivalent to impact of 0.25kg mass dropped from 200mm above impacted surface. Print Rooms 300 . . . . . . . . . . . .nw or ww . . . . . . . . . . .1 or 2
c- Banks and Building Societies
IK05 Protected against 0.7 joules impact. Counter, office area 500 . . . . . . . . . . . .nw or ww . . . . . . . . . . .1 or 2
Equivalent to impact of 0.25kg mass dropped from 280mm above impacted surface. Public Area 300 . . . . . . . . . . . .nw or ww . . . . . . . . . . .1 or 2

Schools
IK06 Protected against 1 joules impact.
General class and conference rooms 250 . . . . . . . . . . . .nw or ww . . . . . . . . . . .1 or 2 Extra light for blackboard (500 lux)
Equivalent to impact of 0.25kg mass dropped from 400mm above impacted surface. Libraries, laboratories, art rooms areas 500 . . . . . . . . . . . .nw or ww . . . . . . . . . . .1 or 2 Higher illuminance for demonstration
IK07 Protected against 2 joules impact. Music and lecture rooms 250 . . . . . . . . . . . .nw or ww . . . . . . . . . . . .1
Indoor game rooms, gymnasium and swiming pools 300 . . . . . . . . . . . . . .nw . . . . . . . . . . . . .1 or 2 Impact proof fittings.
Equivalent to impact of 0.5kg mass dropped from 400mm above impacted surface.
Places of worships / Churches
IK08 Protected against 5 joules impact. Entrances 30 . . . . . . . . . . . .nw or ww . . . . . . . . . . .1 or 2 Coordinate the design of the system
Equivalent to impact of 1.7kg mass dropped from 300mm above impacted surface. Naves 90 . . . . . . . . . . . .nw or ww . . . . . . . . . . .1 or 2 to the sacred character and
Orchestra or choir areas 120 . . . . . . . . . . . .nw or ww . . . . . . . . . . . .1 special architecture of these areas.
IK09 Protected against 10 joules impact.
Equivalent to impact of 5kg mass dropped from 200mm above impacted surface. Multipurpose Sport Halls special rules apply
Shops and Stores
IK10 Protected against 20 joules impact.
Shops, boutiques and salesrooms effect 300 . . . . . . . . . . . . . .nw . . . . . . . . . . . . . . .1 Extra spots for sales promotion
Equivalent to impact of 5kg mass dropped from 400mm above impacted surface. Storerooms 120 . . . . . . . . . . . .nw or ww . . . . . . . . . . . .3
Packing and dispatch 250 . . . . . . . . . . . .nw or ww . . . . . . . . . . . .3
Supermarkets departments 750 . . . . . . . . . . . .nw or ww . . . . . . . . . . .1 or 2 ìNaturalî lamps for food
Multiple stores 500 . . . . . . . . . . . .nw or ww . . . . . . . . . . .1 or 2 Extra spots
Shop windows 1000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Specialized shops special rules apply
A6 A7
M I N I M U M R E Q U I R E M E N T S F O R L I G H T I N G T U B U L A R F L U O R E S C E N T L A M P S T 8 ( Φ 2 6 m m )

a- Standard line
Room purpose or work involved Rated illuminance (lux) Fluorescent lamp Remarks
colour designation colour index Rated lamp Wattage (W) Length (mm) Colour Color temperature (oK) Luminous flux (lm)
18 590 DW 6000 1050
Theatres and Concert Halls NW 4000 1100
Cinemas and theatres 60 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Coordinate with architecture NW 4000 1150
WW 3000 1150
Concert halls 120
Conference rooms and banquetting halls 300 36 1200 DW 6000 2500
NW 4000 2600
Hotels and Restaurants NW 4000 2850
WW 3000 2850
Refreshment rooms, self service 200 . . . . . . . . . . . .nw or ww . . . . . . . . . . . .1 Extra light for showcases
Kitchens 300 . . . . . . . . . . . .nw or ww . . . . . . . . . . .1 or 2 58 1500 DW 6000 4000
NW 4000 4100
Hotel rooms, restaurants, cafÈs 150 . . . . . . . . . . . . . .ww . . . . . . . . . . . . . . .1 Extra light over beds, mirrors and desks NW 4000 4600
WW 3000 4600
Homes
Bedrooms 50 to 150 . . . . . . . . . . . .ww . . . . . . . . . . . . .1 or 2 Extra reading light over bed heads b- Improved color rendering and best efficiency (Group 1B)
Bathrooms 100 . . . . . . . . . . . .nw or ww . . . . . . . . . . .1 or 2 ww over mirror
Kitchen and working areas 300 . . . . . . . . . . . .nw or ww . . . . . . . . . . .1 or 2 Rated lamp Wattage (W) Length (mm) Colour Color temperature (oK) Luminous flux (lm)
Living rooms 50 to 150 . . . . . . . . .nw or ww . . . . . . . . . . .1 or 2 18 590 DW 6000 1300
Studies desk 300 . . . . . . . . . . . .nw or ww . . . . . . . . . . .1 or 2 Extra table lighting NW 4000 1350
WW 3000 1350
Exhibition rooms WW 2700 1350
Museums, art galleries 300 . . . . . . . . . . . .nw or ww . . . . . . . . . . . .1 Provide adequate and/or indirect 36 1200 DW 6000 3250
vertical lighting NW 4000 3350
Showrooms, exhibition halls and trade fair halls 500 . . . . . . . . . . . .nw or ww . . . . . . . . . . .1 or 2 Extra spots WW 3000 3350

Industry 58 1500 DW 6000 5000


NW 4000 5200
Side rooms, entries and halls 30 . . . . . . . . . . . .nw or ww . . . . . . . . . . .1 or 2 WW 3000 5200
Semi-automatic production 100 . . . . . . . . . . . .nw or ww . . . . . . . . . . . .3 WW 2700 5200
General Stores 100 . . . . . . . . . . . .nw or ww . . . . . . . . . . .1 or 2
Average visual tasks: food, metal c- Best color rendering (Group 1A)
and plastic industries, auto garage 300 . . . . . . . . . . . . . .nw . . . . . . . . . . . . .1 or 2
Rated lamp Wattage (W) Length (mm) Colour Color temperature (oK) Luminous flux (lm)
Chemical and painting industries 450 . . . . . . . . . . . .tw or nw . . . . . . . . . . . . .1
Textile manufacture, workshops, central rooms 500 . . . . . . . . . . . . . .nw . . . . . . . . . . . . . . .1 Avoid reflection 18 590 DW 5400 1000
Precision assemblies 750 . . . . . . . . . . . . . . nw . . . . . . . . . . . . .1 or 2 NW 3800 1000
WW 3000 1000
Dress making 750 . . . . . . . . . . . . . .nw . . . . . . . . . . . . . . .1
Graphic arts 750 . . . . . . . . . . . .tw or nw . . . . . . . . . . . .1A 36 1200 DW 5400 2350
Tool making 800 . . . . . . . . . . . .tw or nw . . . . . . . . . . . . .1 NW 3800 2350
Colour inspection 1000 . . . . . . . . . . . .tw or nw . . . . . . . . . . . .1A Special work plane lighting recommended WW 3000 2350
58 1500 DW 5400 3700
Testing areas 1000 . . . . . . . . . . . .tw or nw . . . . . . . . . . .1 or 2 NW 3800 3750
Critical works: fine mechanics and electronics, WW 3000 3750
watchmaking, fine needle work 500 . . . . . . . . . . . .tw or nw . . . . . . . . . . .1 or 2
Notes: Refer to DIN 5035 table for colour rendering properties
Hospitals Special rules apply
A8 A9
T U B U L A R F L U O R E S C E N T L A M P S T 1 2 ( Φ 3 8 m m ) C O M PA C T F L U O R E S C E N T L A M P

a- TC-L Colour rendering group 1B (Ra 80-89) (Base 2G11)


a- Standard line
Rated lamp Wattage (W) Length (mm) Colour Color temperature (OK) Luminous flux (lm)
Rated lamp Wattage (W) Length (mm) Colour Color temperature (OK) Luminous flux (lm)
20 590 DL 6500 950
W 3450 1150 18 217 NW 4000 1200
CW 4000 1150 WW 3000 1200
WW 2950 1150 WW 2700 1200
N 4050 1050 24 317 NW 4000 1800
40 1200 DL 6500 2450 WW 3000 1800
W 3450 2950 WW 2700 1800
CW 4000 2950
36 411 DW 6000 2900
WW 2950 2950
N 4050 2500 NW 4000 2900
WW 3000 2900
65 1500 DL 6500 3900 WW 2700 2900
W 3450 4750
CW 4000 4750 40 533 NW 4000 3500
WW 2950 4750 WW 3000 3500
N 4050 4000 WW 2700 3500
55 533 NW 4000 4800
b- Improved color rendering and best efficiency (Group 1B) WW 3000 4800
Rated lamp Wattage (W) Length (mm) Colour Color temperature (OK) Luminous flux (lm) WW 2700 4800
20 590 CW 4000 1450 b- TC-L Colour rendering group 1A (Ra 90-100) (Base 2G11)
WW 2950 1450
Rated lamp Wattage (W) Length (mm) Colour Color temperature (OK) Luminous flux (lm)
40 1200 CW 4000 3350
WW 3950 3350
18 217 DW 5400 750
65 1500 CW 4000 5300 NW 3800 750
WW 2950 5300 WW 3000 750
24 317 DW 5400 1200
Notes: Refer to DIN 5035 table for colour rendering properties NW 3800 1200
WW 3000 1200
36 411 DW 5400 1900
NW 3800 1900
WW 3000 1900
40 533 DW 5400 2200
T U B U L A R F L U O R E S C E N T L A M P S T 5 ( Φ 1 6 m m ) 55 DW 5400 3000
55 WW 3000 3000

c- TC-D Colour rendering group 1B (Ra 80-89) (Base G24d)

a- FH, GROUP 1B,G5 base Rated lamp Wattage (W) Length (mm) Colour Color temperature (OK) Luminous flux (lm)
Rated lamp Wattage (W) Length (mm) Colour Colour temperature (OK) Luminous flux (lm)
18 153 NW 4000 1200
14 549 DW 6000 1220 WW 3000 1200
NW 4000 1270 WW 2700 1200
WW 3000 1270 26 172 NW 4000 1800
28 1149 DW 6000 2580 WW 3000 1800
NW 4000 2720 WW 2700 1800
WW 3000 2720 Notes: Refer to DIN 5035 table for colour rendering properties
35 1449 DW 6000 3290
NW 4000 3430
WW 3000 3430
A10 A11
C O M PA C T F L U O R E S C E N T L A M P S D I S C H A R G E L A M P S ( E l l i p t i c a l )

Compact Fluorescent lamps TC-D (DULUX D + PLC)


Rated lamp Wattage (W) Length (mm) Light colour Color rendering index Color number Base Luminous flux Lumen a- Metal halide. HQI-E, E40 base
10 112 Cool White 1 21 G24 d-1 600 Rated lamp Wattage (W) Diameter (mm) Colour rendering factor Luminous flux (lm) Colour temperature (OK)
112 Warm White 1 31 G24 d-1 600
112 Interna 1 41 G24 d-1 600 250 90 1A 19000 5200
400 120 1A 32000 5900
13 141 Cool White 1 21 G24 d-1 900 2A 45000 3800
141 Warm White 1 31 G24 d-1 900
141 Interna 1 41 G24 d-1 900
18 171 Cool White 1 21 G24 d-2 1200
171 Warm White 1 31 G24 d-2 1200 b- High pressure sodium, NAV, E40 lampholder
171 Interna 1 41 G24 d-2 1200
Rated lamp Wattage (W) Diameter (mm) Colour rendering factor Luminous flux (lm) Colour temperature (OK)
26 184 Cool White 1 21 G24 d-3 1800
184 Warm White 1 31 G24 d-3 1800 250 90 4 25000 2000
184 Interna 1 41 G24 d-3 1800 400 120 4 47000 2000
Compact Fluorescent lamps TC (DULUX S + PLS)
Rated lamp Wattage (W) Length (mm) Light colour Color rendering index Color number Base Luminous flux Lumen
c- High pressure sodium, NAV, E40 lampholder
5 108 Cool White 1 21 G23 250
Rated lamp Wattage (W) Diameter (mm) Colour rendering factor Luminous flux (lm) Colour temperature (OK)
108 Warm White 1 31 G23 250
108 Interna 1 41 G23 250
250 90 4 33000 2000
7 138 Cool White 1 21 G23 400 400 120 4 55500 2000
138 Warm White 1 31 G23 400
138 Interna 1 41 G23 400 250 90 2B 22000 2200
400 120 2B 37500 2200
9 168 Cool White 1 21 G23 600
168 Warm White 1 31 G23 600
168 Interna 1 41 G23 600
11 238 Cool White 1 21 G23 900 d- Mercury lamps, HQL, E40 lampholder
238 Warm White 1 31 G23 900
238 Interna 1 41 G23 900 Rated lamp Wattage (W) Diameter (mm) Colour rendering factor Luminous flux (lm) Colour temperature (OK)

Compact Fluorescent lamps TC - L (DULUX L + PLL) 250 90 3 13000 3900


400 120 3 22000 3800
Rated lamp Wattage (W) Length (mm) Light colour Color rendering index Color number Base Luminous flux Lumen
250 90 3 14000 3100
18 217 Cool White 1 21 2G11 1200
400 120 3 24500 3000
217 Warm White 1 31 2G11 1200
217 Interna 1 41 2G11 1200 Note: Refer to DIN 5035 table for color rendering properties
24 317 Cool White 1 21 2G11 1800
317 Warm White 1 31 2G11 1800
317 Interna 1 41 2G11 1800
36 411 Cool White 1 21 2G11 2900
411 Warm White 1 31 2G11 2900
411 Interna 1 41 2G11 2900
A12 A13
H I G H I N T E N S I T Y D I S C H A R G E L A M P S T U B U L A R F L U O R E S C E N T L A M P S T 5 ( Φ 1 6 m m )

a- Metal halide single ended HQI-T a- HO, GROUP 1B,G5 base


Rated lamp Wattage (W) Diameter (mm) Length (mm) Light Colour Base Luminous flux lumen Rated lamp Wattage (W) Length (mm) Colour Colour temperature (OK) Luminous flux (lm)

35/WDL 25 84 Warm White G12 2400 24 549 DW 6000 1600


70/NDL 25 84 Neutral White G12 5500 NW 4000 1750
70/WDL 25 84 Warm White G12 5200 WW 3000 1750
150/NDL 25 84 Neutral White G12 12500
54 1149 DW 6000 4100
150/WDL 25 84 Warm White G12 12000
NW 4000 4450
WW 3000 4450
b- Metal halide double ended tubular HQI-TS
Rated lamp Wattage (W) Diameter (mm) Length (mm) Light Colour Base Luminous flux lumen 49 1449 DW 6000 4100
NW 4000 4300
70/NDL 20 114.2 Neutral White RX 7s 5500 WW 3000 4300
70/WDL 20 114.2 Warm White RX 7s 5000
70/WDL Plus 20 114.2 Warm White RX 7s 6000
150/NDL 23 132 Neutral White RX 7s-24 11250
150/WDL 23 132 Warm White RX 7s-24 11000

c- Metal halide clear - tubular HQI-T LV H A L O G E N L A M P


Rated lamp Wattage (W) Diameter (mm) Length (mm) Light Colour Base Luminous flux lumen

250/D 46 225 Daylight E40 19000


400/D 46 285 Daylight E40 33000
1000/D 76 340 Daylight E40 80000 b- Halospot 111, aluminium reflector, (G53 base)
2000/D 100 430 Daylight E40 170000 Rated lamp Wattage (W) Diameter (mm) Beam angle (degrees) Luminous intensity (cd)

d- Metal halide coated elliptical HQI-E 35 111 4O 30000


Rated lamp Wattage (W) Diameter (mm) Length (mm) Light Colour Base Luminous flux lumen 4O 45000
8O 1000
250/D 90 226 Daylight E40 17000 24O 2500
400/D 120 290 Daylight E40 31000 50 111 4O 50000
400/N 120 290 Neutral White E40 40000 8O 20000
400/N Clear 120 290 Neutral Clear White E40 42000 24O 3500
1000/N 165 380 Neutral White E40 80000

e- High Pressure Sodium Lamps coated elliptical son (HPS)


Rated lamp Wattage (W) Diameter (mm) Length (mm) Light Colour Base Luminous flux lumen

50/E 70 156 - E27 3500 H I G H I N T E N S T Y D I S C H A R G E L A M P S


70/E 70 156 - E27 5600
150 90 226 - E40 14000
250 90 226 - E40 25000 Mercury vapor lamps HQL
400 120 290 - E40 47000
1000 165 400 - E40 120000 Rated lamp Wattage (W) Diameter (mm) Lengtht (mm) Light Colour Base Luminous flux lumen
50 55 130 - E27 1800
f- High pressure sodium lamps clear tubular son (HPS) 80 70 156 - E27 3800
Rated lamp Wattage (W) Diameter (mm) Length (mm) Light Colour Base Luminous flux lumen 125 75 170 - E27 6300
250 90 226 - E40 13000
150 46 211 - E40 14500 400 120 290 - E40 22000
250 46 257 - E40 27000 700 140 330 - E40 40000
400 46 275 - E40 48000 1000 165 390 - E40 58000
1000 65 400 - E40 130000

f- High pressure sodium lamps double ended HPS-TS


Rated lamp Wattage (W) Diameter (mm) Length (mm) Light Colour Base Luminous flux lumen

250 23 206 - Fc 2 25500


400 23 206 - Fc 2 48000
A14 A15
L O W V O LTA G E H A L O G E N L A M P S CIRCUIT DIAGRAMS - FLUORESCENT LAMPS

Normal or switchstart ballast


In this type of circuit, starting current passes through a bimetal starter connected parallel to the lamp and preheats the lamps elctrode. Meanwhile, due to
Low voltage Tungsten halogen lamps with transverse filament the difference in the nature of the alloys, the bimetal opens reducing current to zero and causing a voltage surge dv = this voltage surge causes
ionization and the lamp lights up.
Rated lamp Wattage (W) Diameter Length (mm) Lamp voltage volt Beam Base Luminous flux lumen
10 9 31 12 - G4 140 Inductive circuit for one lamp
20 9 31 12 - G4 350 Not compensated P.F. ~ 0.5 lagging L N
50 12 44 12 - GY6.35 950 VG
C
Decostar 51 low voltage lamps with dichroic reflector
FL
Rated lamp Wattage (W) Diameter Length (mm) Lamp voltage volt Beam Base Luminous flux lumen
20 51 45 12 12o GU 5.3 340
S
51 45 12 36o GU 5.3 340
51 45 12 60o GU 5.3 340
35 51 45 12 8o GU 5.3 670
51 45 12 18o GU 5.3 670 Capacitive circuit for one lamp
51 45 12 38o GU 5.3 670 Capacitive P.F. ~ 0.5 leading L N
VG C
50 51 45 12 12 o
GU 5.3 1040 Ballast and capacitor arranged in series. Circuit suitable for ripple frequency control.
51 45 12 24o GU 5.3 1040
51 45 12 30o GU 5.3 1040 FL
51 45 12 38o GU 5.3 1040
51 45 12 60o GU 5.3 1040
S
75 51 45 12 14o GU 5.3 1280
51 45 12 24o GU 5.3 1280
51 45 12 38o GU 5.3 1280
Duo circuit - compensated P.F. ~ 1
By combining one inductive and one capacitive circuit, lead/lag power factor correction NL
is attained. Stroboscopic effects are largely eliminated, and the circuit is suitable for S
ripple frequency control. VG
FL

S
C VG
FL

Color appearance table according to DIN 5035 Color rendering group according to DIN 5035 Compensated circuit - P.F. ~ 0.90 L N
The power factor is corrected by means of a capacitor connected parallel to the mains. VG

Color Temperature ToK Group Ra range FL

Warm white T <3300 o K 1A Ra >90


WW 1B 80<Ra <90 S
Neutral white 3300 o K <T <5000 o K 2A 70<Ra <80
NW 2B 60<Ra <70 Tandem circuit - not compensated P.F. ~ 0.5
Daylight white T >5000 o K 3 40<Ra <60 Two lamps wired in series are operated with only one ballast. 110 V starters required !
DW In cases of excessive ignition time with tandem circuits, one of the two starters should S
4 20<Ra <40 VG
be reversed (i.e. turned through 180 ).
L FL
Tandem circuit are suitable with following lamps:
Lamp Length N
T26/18 W 590 mm FL
T 38/20 W 590 mm
S
Key : VG = ballast; FL = Fluorescent lamp; L = phase; N = Neutral
Quick starting with elctronic starters is possible by using one ballast per lamp.
A16 A17
Noise
PC electronic ballasts Ballasts are manufactured from laminated sheet steel and the constant reversal of the magnetic field sets up harmonic vibrations in the steel
cores that can sometimes be heard. However all ballasts used by Nardeen have their noise levels complying with standards mainly IEC, VDE,
Single lamp - P.F.~ 0.95 Twin Lamp - P.F.~ 0.95 DIN, BSS, SASO, etc...

Power Factor Correction


Since a ballast is mainly a coil, the fluorescent lamp circuit will be inductive, and a capacitor is required to improve the power factor from a typi-
cal figure of 0.5 to 0.9. The capacitor can be connected either in serie or in parallel to the circuit. A better solution would be the use of the
lead/lag duo circuit i.e. connecting to one electrical circuit two types of wiring, one having an inductive non compensated circuit, and the other a
7
capacitive over-compensated circuit. This duo circuit has also the advantage of reducing stroboscopic effects.
L
L 7 6 Following values are nominal for a corrected power factor cos ( 0.90 to 0.95).
6 5

FL
PC PC 4
2 3 Voltage Wattage
N 1 2
N 1 1x18w 2x18w 4x18w 6x18w 1x36w 2x36w 3x36w 4x36w 1x58w 2x58w
220V 50/60Hz 4m F 4m F 8m F 12.5m F 4m F 8m F 12.5m F 2x8m F 8m F 12.5m F
Parallel 220 V 220 V 220 V 220 V 220 V 220 V 220 V 220 V 220 V 220 V
220V 50/60Hz 2.9m F 3.6m F 3.6m F 2x3.6m F 3.6m F 3.6m F 2x3.6m F 2x3.6m F 5.7m F 5.7m F
Series 440 V 420 V 420 V 420 V 420 V 420 V 420 V 420 V 420 V 420 V

Rapid start ballast Dimming with fluorescent lamps


Two types of rapid start ballasts are available. One is to be used with rapid start lamps having a strip along their length, the other to be used with normal (Electronic 1-10VDC Digital Dimming
fluorescent lamps and is called: trigger start ballast. Features: ø 26 mm
In the first case, ballast has built-in filament windings which energize the low voltage cuthode in the rapid start lamp. A stream of ions emitted from the 1- Control voltage 1-10VDC
cathodes prepares the gaz in the lamp for lighting. The high open circuit voltage supplied by the ballast then strikes on arc through the lamp causing it to 2- Dimming Range 0-100% L ø 26 mm
light. 3- Low starting Level
Trigger start ballast contains preheat winding which enable regular lamp filaments to be heated in one second. They operate similarly to rapid start bal- 1-10 VDC N
4- Optimum Efficacy over the whole dimming range
lasts, but they require higher open circuit voltage. control +
5- Flicker free light <1 mA C1
6- No blinking or noise _
Rapid start single lamp circuit - P.F. = 0.9 C0
Capacitor is built in ballast housing.
7- Very low magnetic field
This circuit is the same for trigger and rapid start ballast. 8- Very low mains current harmonics
9- Stabilized output
Rapid start twin lamp circuit - P.F. = 0.9 10- High number of tubes per dimmer
Capacitor is built in ballast housing. 11- High power factor
This circuit is the same for trigger and rapid start ballast. 12- No starting aids as earthed metal surface or strips on the lamps L ø 26 mm
needed. 1-10 VDC N
LINE 13- Energy savings 15-30% at 100% light. control
<1 mA C1+
_
LINE C0
Electronic Phase-Shift Dimming
RS Features:
1- Dimming range 10-100%
RS 2- Low starting level
3- Optimum efficacy over the whole dimming range
4- Flicker free light 1 5
5- No blinking or noise 2 6 ø 26 mm
FL N 3 7
6- Very low magnetic field 4 8
FL 7- Very low mains current harmonics N ø 26 mm
L Bottom Filter
FL 8- Stabilized output Dimmer Load chokes Electronic unit
9- High number of tubes per dimmer ø 26 mm
10- High power factor 1 5
2 6 ø 26 mm
11- No starting aids as earthed metal surface or strips on the lamps 3 7
needed. 4 8
ø 26 mm
12- Energy savings 15-30% at 100% light.
A18 A19
B A L L A S T S & C A PA C I TO R S T E C H N I C A L D ATA F O R H I D L A M P S

High Pressure Sodium (HPS)

Type of Ballast and WattageCircuit Voltage VCurrent A Standard power Factor Weight Kg F + 10% Power Factor Current A Weight Kg

70 220 1.00 0.36 1.50 8 0.46 0.12


100 220 1.20 0.40 2.20 10 More 0.68 0.13
150 220 1.80 0.40 2.00 18 Than 0.74 0.15
250 220 3.00 0.37 4.90 30 90% 1.30 0.20
400 220 4.45 0.40 6.20 40 1.60 0.25
1000 220 10.3/95 0.45 14.20 85/75 3.20 0.52

High Pressure Mercury (HPM)

Type of Ballast and WattageCircuit Voltage VCurrent A Standard power Factor Weight Kg F + 10% Power Factor Current A Weight Kg

50 220 0.61 0.44 0.90 6 0.30 0.08


80 220 0.80 0.51 1.10 6 0.45 0.10
125 220 1.15 0.58 1.40 10 More 0.70 0.12
175 220 1.45 0.58 1.40 10 Than 0.92 0.12
250 220 2.13 0.58 2.00 15 90% 1.34 0.15
400 220 3.25 0.60 5.00 25 2.00 0.18
1000 220 7.50 0.63 10.00 60 4.62 0.30

Metal Halide (MH)

Type of Ballast and WattageCircuit Voltage VCurrent A Standard power Factor Weight Kg F + 10% Power Factor Current A Weight Kg

250 220 2.13 0.37 4.90 30 1.30 0.20


400 220 3.25 0.37 6.20 30 1.60 0.20
1000 220 7.50 0.45 14.20 85/75 More 3.20 0.52
2000 220 8/8.8 0.45 19.00 100 Than 3.40 0.60
2000 380 10.3/88 0.46 19.00 40 90% 1.8 0.25
A20 A21
R E F L E C T I O N FA C T O R S O F VA R I O U S M AT E R I A L S A N D C O L O U R S LUMINAIRE C L A S S I F I C AT I O N A C C O R D I N G T O L U M I N O U S F L UX

Material Reflection Factor Material Reflection Factor


10% 10% 10% 10% 10%
Birch ................................0,60 Glass, clear ....................0,06 - 0,08 DIN 5040
30% 30% 30% 30% 30% Brick, red ........................0,05 - 0,25 Glazed tiles, white ............0,60 - 0,75 Luminaire photometry classification as per standard is composed of one letter and two figures(ex:A60). The letter (A, B, C, D, E) indica
Concrete ........................0,15 - 0,40 Walnut, dark ..................0,15 - 0,20
50% 50% 50% 50% 50% the percentage of luminous flux emitted in the upper and lower hemispheres. The closer it is to the letter A, the higher is the percentage
Oak, light ........................0,40 Plaster ............................0,80
Oak, dark ........................0,15 - 0,20 Carbon black or velvet ..0,02 - 0,10 the flux emitted in the lower hemisphere. The figures that follow refer to the flux directed onto the working plane and the ceiling, respec
70% 70% 70% 70% 70% Enamel, white ................0,65 - 0,75 tively, in the typical configuration provided for by the standard.
Glass/Aluminium miror ..0,95
80% 80% 80% 80% 80%
UTE C71-121
Luminaire photometry classification is composed of the efficiency in the lower hemisphere followed by a letter plus the efficiency in the
upper hemisphere followed by another letter (ex: 0.5D+0.24T). Letters range from “A” to “J” and represent the luminous flux percentage
M A I N T E N A N C E FA C T O R inside given solid angles. If the letter T is present, this means that part of the luminous flux is emitted into the upper hemisphere.

CIBSE TM5
Luminaire photometry classification is divided into ten categories (BZ1 to BZ10). Each category refers to the percentage of luminous flu
Maintenance factor depends on various parameters: emitted in the lower hemisphere that directly reaches the working plane in a standard configuration. This is why this classification also
Lamp life (for example for tubular fluorescent T26 is 8000 hours)
Frequency for maintenance (for example every year for cleaning and every 3 years for replacing lamps) depends upon room index. For example, luminaires classified as BZ1 emit a greater amount of luminous flux onto the working plane th
Lamp factor (flux decrease and lamp survival) BZ2 to BZ10 luminaires.
Luminaire factor (depends if it is closed, opened ,IP..)
Local factor (frequency of cleaning the room, level of dust, direct/indirect illuminance, local index)
CIE publications
Luminaire photometry classification as per CIE is composed of five ratios N1, N2, N3, N4, N5 represent the
luminous flux percentage efficiency inside given solid angles.
To maintain a level of illuminance, the following table gives values for a pre-project:
Environment Open fitting Fitting suitable for the environment
Clean 0.8 0.9
P H O T O M E T R I C C U R V E S
Average 0.672 0.8
Dirty 0.64 0.7

POLAR CURVE
The whole of the measured of luminous intensities emitted by a luminaire in all directions forms
the photometric solid. Usually not all information regarding the photometric solid is given,
but only as regards two vertical planes normal to each other that cross the optical centre
of the luminaire. (C0-C180, C90-C270)
Luminous intensity values represented in polar coordinates on a plane define a line that is called
(photometric curve). They are generally expressed as cd/klm, refered to a source emitting a
luminous flux equal to a 1000lm.
To obtain the actual value, you should multiply the value shown on the diagram by the actual flux
of the lamp used.

CARTESIAN CURVE
For the luminaires with intensive distribution, and having revolution axis, the luminous intensity is
usually represented in these coordinates for more precision.

ISOLUX CURVE
This curve connects points on the plane having same light density E(lux).
A22 A23
G L A R E C O N T R O L

LOW / VERY LOW LUMINANCE


The new definitions permit the clarification of features that characterize the luminance distribution of luminaires. These terms which have been used
currently donít respond to precise values, but follow some standards or requirements, such as Bodman-Sollner diagram, CIBSE LG3, DIN5035 part 7,
cut-off angles...

Bodman-Solner diagrams
Glare can be caused by lamps or luminaires (direct glare) as well as by high luminance reflected by bright surfaces(reflected glare).
Average luminance of each luminaire should not exceed luminance restriction curve shown in the figures with respect to the glare critical angle
45O< α < 85O . The luminaire luminance curve should be positionned in the left side of the threshold in function of the position of the observer, dimension of
the room, required system quality class and level of the illuminance.
Luminance restriction curves apply:
to general room lighting and general oriented lighting at working stations
to rooms having a parallele piped shape
when room reflection factors are as follows:0.7/0.8 for the ceiling, 0.4/0.6 for the walls and 0.1/0.2 for the floor.
The luminances in the horizontal axe are graduated in logarithmic scale. The angles of observation in the left vertical axe are graduated in linear scale. These
angles are defined by the axe of vision to the luminaire and the vertical axe. It could be defined also by the tangent tg a =a/hv; a is the horizontal distance
105∞ 105∞ between the observer and the luminaire, hv is the height difference between the eye of the observer and the luminaire. The tangent values are reported to the
right vertical axe, in correspondence with the angles.
90∞ 90∞

75∞ 75∞ Class quality table


Glare Class of quality Activity
60∞ 60∞ Inexistant A Execution of very exigent visual task, ex: electronic assembly
80
B Execution of particularly exigent visual task, ex: fine control.
Execution of moderated visual task, but demanding important
120 and continuous concentration, ex: office work, small pieces assembly.
45∞ 45∞
Light C Execution of moderated visual task, ex: normal task for seated worker,
160 normal size pieces assembly for a worker in stand up position.
D Execution of simple visual task, with a normal concentration for workers who
are moving frequently in a limited zone, mounting of important dimension pieces.
200
Severe E Locals where people donít have fixed task position, moving for execution of low
30∞ I ( cd/klm ) 30∞
visual task. Locals where tasks arenít done continuously by the same people.
C0 C90

gamma C 0.0 C 15.0 C 30.0 C 45.0 C 60.0 C75.0 C 90.0

0.0o 215.40 215.40 215.40 215.40 215.40 215.40 215.40


5.0o 215.10 215.80 215.50 215.00 215.80 214.30 214.60
10.0o 215.50 216.00 215.20 213.90 213.20 211.70 212.10 Cl. Phot. éclairement nominal Nominal lighting (lux)
15.0o 215.50 215.30 214.20 211.70 210.20 207.50 208.10 A 1.15 2000 1000 500 250
20.0o 213.10 212.20 211.50 207.90 205.70 201.00 201.50 B 1.50 2000 1000 500 250
25.0o 207.50 205.80 206.10 201.00 199.10 192.90 193.30 C 1.85 2000 1000 500 250
30.0o 197.40 194.00 196.40 190.50 190.00 181.60 182.20 D 2.20 2000 1000 500 250
35.0o 176.80 173.10 180.10 175.00 174.30 164.90 166.60 E 2.55 2000 1000 500 250
85° 8
40.0o 154.00 149.10 157.60 149.40 155.20 144.30 147.10 a 6

hv
45.0o 129.00 120.20 125.40 118.70 124.90 118.00 125.00
75° 4
50.0o 97.30 91.90 100.60 92.80 99.70 92.50 98.60
3
55.0o 69.80 67.20 72.50 66.20 73.70 70.60 74.30
60.0o 51.30 46.10 47.60 41.00 48.40 49.30 55.10
hv 65° 2
65.0o 39.70 32.50 29.00 22.40 29.70 34.60 43.50
70.0o 29.70 24.10 20.20 16.80 20.50 25.70 33.10 55°
75.0o 21.10 17.80 15.20 13.90 16.40 19.30 24.10
80.0o 12.40 11.30 12.40 10.80 13.70 13.60 14.40 45°
85.0o 5.50 3.70 6.20 5.10 7.40 5.80 7.70 789
1000
2 3 4 5 6 7 89 2
10000 cd/m2
3
90.0o 0.40 0.30 0.40 0.30=. 0.40 0.30 0.40
A24 A25
G L A R E C O N T R O L
CIBSE LIGHTING GUIDE LG3
(the chartered institute of building services engineers lighting guide No.3 areas for visual display terminals)
English CIBSE standards classify luminaires into three categories CAT1 , CAT2 and CAT3. LG3 takes into account how the computer is used, 2.80m
when it is used and how the space in which it is placed is designed. 0.85m
m
8.6
4.5
Very low luminance cat1: m
Luminaires have the average luminance above the 55O elevation angle restricted to less than 200cd/m2 , and a maximum patch luminance of
500cd/m2 above the same angle.
D E T E R M I N AT I O N O F L U M I N A I R E S N U M B E R S
Very low luminance cat2:
Luminaires have the average luminance above the 65O elevation angle restricted to less than 200cd/m2 , and a maximum patch luminance of
500cd/m2 above the same angle.
Room index K = 8.6 x 4.5
(2.80 - 0.85) x (8.6 + 4.5)
Low luminance cat3:
Luminaires have the average luminance above the 75O elevation angle restricted to less than 200cd/m2 , and a maximum patch luminance of K = 1.51 say 1.50
500cd/m2 above the same angle.
The resulting illuminance on the working plane of a room (0.85m above Example:
floor level) is a function of the following parameters: Find the required number of RMA 2/36 fittings to illuminate an
DIN 5035 PART 7 office Dimensions:
(German standard , lighting of rooms with VDU work stations or VDU assisted workplaces). 1 The luminous flux emitted by the lamps L = 8.6 m
In accordance with DIN 5035, part 7, the mean luminance of surfaces that reflect in a VDU, including furnishing and windows, must be not higher 2 The luminaire in which the lamps are enclosed W = 4.5 m
than 200cd/m2 , while maximum luminance must be limited to 400cd/m2 . In the case of luminaires that reflect in a VDU, the provisions of DIN5035 3 The shape of the room, referred to as the Room Index H = 2.8 m
are as follows: beyond the luminance limit angle, the angle at which a luminaire starts to become visible to the operator in a VDU, mean luminance Lamps are 36 w - Neutral White, Flux per lamp: 2600 m
4 The reflective properties of the ceiling, walls and floor, referred to as
of the luminous surfaces in the planes C0-C180 and C90-C270 must not exceed 200cd/m2 .
The use of special VDU luminaires, with a luminaire limit angle of 50O , only makes real sense for large offices. In smaller rooms luminance at the Reflection Factors. Maintenance factor:
the emission angle provided with these luminaires would not in any case be visible in the computer. Therefore, the use of luminaires with a 60O 5 The maintenance factor which takes into account the aging of the environment is clean, fitting is open type,
luminance limit angle is to be recommended. installation and lamps are replaced at 80% of their rated life: M = 0.80
Combining parameters 2,3 and 4, results into the Utilisation Factor of an Utilization factor:
installation, i.e. a specific luminaire installed in a given room having fixed assuming reflection factors of Ceiling 70% - Walls 50%
reflection factors. Utilization factor U is given by the photometric data of the RMA 2/36 fittings:
The Room Index is given by the formula: K = LxW
Optimal reflection at any point patch luminances above critical angle U = 0.55
h (L + W)
Therefore:
Where L x W are the length and width of the room and h is is the 500 x 8.6 x 4.5
distance between the fittings and the working plane located at 0.85m N = = 8.46 fittings
2 x 2600 x 0.55 x 0.80
above floor level.
See tables page 121 to 127 for determining parameters 1, 4 and 5 With 8 fittings installed, the illuminance level will be:

No patch luminances above critical angle E = N x h x F x U x M = 8 x 2 x 2600 x 0.55 x 0.80


ExLxW LxW 8.6 x 4.5
The number of fittings is calculated from: N =
nxΦxUxM
This value is still acceptable since it differs about 5% from the requested
where: E = Average required illuminance on the working plane. See Tables value E = 473 lux.
page (121-122)
n = Number of tubes per fitting
U = Utilization factor given for every type of fitting
T5 LUMINAIRE OPTICS Φ = Lumen flux of one tube
These luminaires offers high levels of light output. To control the glare, without decreasing the luminaire efficiency, we have developed special M = Maintenance factor
optics for the T5 tubular lamps.

Ladder effect
Ladder effect is series of high luminance patches which can appear along the length of the reflectors. This patch luminance must not exceed
500 cd/m2 at any angle above the luminance limit angle.
To avoid this effect which is remarkable for the T5 lamps, we have developed special transversal parabolic blades, curved in the upper part to
minimize it. Their partial closed upper side, optimized parabolic ray, upper transversal opening size and height contribute to keep the high effi-
ciency of the luminaire.
A26
Illuminance calculations by points

Horizontal or vertical illuminance at a given point can be calculated from luminous intensity and the relevant geometrical conditions:
Eh:is horizontal illuminance (in lux) Ev:is vertical illuminance (in lux).
d: is the distance between the luminaire and the considered point, (in m) a: is the angle between the vertical axe and the direction
luminaire-point (in degree)
Ia: is the intensity of the luminaire in the direction luminaire to point, (in cd). h: is the height between luminaire point, (in m).
The formula is as follow:
Ia cos a Ia cos3 a
Eh= =
d2 h2
Ia cos3 (90- a) Ia cos2 a sin a
Ev= =
d2 h2
Example: the intensity of a luminaire picked from the polar curve at an angle
of 30O is 540cd, light source flux is 3000lm. The height of the luminaires is 6m
from the working plane.
The illuminance at the working area at an angle of 30O is:
Eh=(3 540 0.64) / 36 = 28.8lux. h
d
Eh

Ev
point

Luminance calculations

The average luminance formula can be used to verify luminaires for compliance with the 200cd/m2 limit. The calculation is performed using
the highest intensity value given, from the series of azimuth angles at the elevation angle in question (55,65 or 75O ).
L:is Average Luminance cd/m2 O
1000: is the intensity per 1000 lumens at elevation angle of (55,65 or 75 ).
N: is number of lamps F0: initial lamp lumen output
l: luminous length(m) W: luminous width(m)
The formula is as follow:
I1000 N F0
L=
1000 I W cos(55,65 or 75O)
Example: luminous dimension of the luminaire is 1.4m 0.5m. The intensity of a luminaire picked from the polar curve at an angle of 65O is 18cd, light
source flux is 3000lm for 1 lamp. L=(18 1 3000) / (1000 1.4 0.5 0.42) = 183.6 cd/m2 .
Riyadh Head Office
P.O. Box 50743 Riyadh, 11533 Nardeen Factory
Kingdom of Saudi Arabia Riyadh Industrial City II
Tel: +966 11 476 5814 Tel: +966-11- 2652144
Fax: +966 11 476 2646 Fax: +966-11- 2652271

Khobar Branch & Showroom JEDDAH Branch & Showroom Madina Office
P.O. Box 31422 Al Khobar, 31952 P.O. Box 6935 Jeddah, 21452 P.O. Box 2720 Madinah Munawarah, 41461
Tel: +966 13 8810616 Tel: +966-12- 660 9086 Tel: +966-14- 8372397
+966 13 881 0608 Fax: +966-12- 665 0387 Fax: +966-14- 8372398
+966 13 881 0927 Email: yjafar@nardeen.com.sa Email: ssouriti@nardeen.com.sa
Ext. 4070
Fax: +966-138810457

www.nardeen.com