Nothing Special   »   [go: up one dir, main page]

Calibration Using Caterpillar Electronic Technician: SMCS - 7610-524-MCH

Download as pdf or txt
Download as pdf or txt
You are on page 1of 6

320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ...

Page 1 of 6

Shutdown SIS

Previous Screen

! "#$ % &'
( ) * +
,-
.

! " #$ %&' %&' %&' %&' %&'


%#( ) &* $ )!'#+ $ % !, )! $# ! # $#)-* .
% .( $/ / ' ()! # / 0 0 1 / 0 0

."//.,

Calibration
SMCS - 7610-524-MCH

Using Caterpillar Electronic Technician


The Caterpillar Electronic Technician service tool is used in order to access the calibration procedures.
For more information, refer to the manual that was provided with the ET.

Similar procedures for calibration may also be performed through the Monitoring System. See Systems
Operation, RENR8068, "Calibration Mode".

The calibration menu is used in order to compensate for the differences in the mechanical components
and the electrical components. The calibration should be performed if the ECM has been replaced or the
ECM was removed. The calibration should be performed if components have been replaced or removed.
Perform all calibrations that are applicable.

Note: Be sure the hydraulic oil temperature is at least 50 °C (122 °F) before performing calibrations.

Accessing Calibrations

Connect the ET to the machine. See Illustration 1. After communication has been established, the ET
will list the electronic control modules that are on the machine.
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 2 of 6

Illustration 1 g01211395
Location of the ET Connector

(Behind Operator Seat, Below Right Console)

(1) ET Connector

(2) Right Console

(3) Back of Operator Seat (Shifted Forward for access)

(4) Backup Control Switches

Note: The ECM must detect specific set-up conditions before beginning the calibration procedure. If a
set-up step is not met, the calibration procedure is aborted.

1. Select the Machine ECM.


320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 3 of 6

Illustration 2 g01211396
Typical screen for accessing calibrations

2. Select "Service" from the main menu.

3. Select "Calibrations" from the "Service" drop-down menu.

The following is a list of all possible calibrations from the "Calibrations" drop-down menu. The
specific calibrations will differ across sales models.

"PRV - Main Pump Flow Limitation Pressure Calibration"

"PRV - Power Shift Pressure Calibration"

"Modulation Input Calibration"

"PRV - Variable Relief Pressure Calibration"

"PRV - Attachment Valves Pressure Calibration"

"Engine Speed Calibrations"


320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 4 of 6

4. From the "Calibrations" drop-down menu, select the desired calibration procedure.

5. Follow the instructions that are provided on the screen.

Note: Additional screens will be displayed to notify the operator of the status of the calibration
procedure.

Typical Calibration Screens

Illustration 3 g01161305
Note: Some calibration procedures require additional equipment.
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 5 of 6

Illustration 4 g01161463
Typical screen for performing calibrations with multiple selections
320D Excavator BZP00001-UP (MACHINE) POWERED BY C6.4 Engine(SEBP5228 - ... Page 6 of 6

Illustration 5 g01211469
Typical screen for performing calibrations