Catolog Bơm Tsurumi .Dòng B
Catolog Bơm Tsurumi .Dòng B
Catolog Bơm Tsurumi .Dòng B
Single-phase
No. of Cores × Outer Dia. No. of Cores × Outer Dia. No. of Cores × Outer Dia.
Code Cables mm Material Code Cables mm Material Code Cables mm Material
mm2 mm2 mm2
a 1 3 × 1.25 10.1 4 × 5.5 16.8 3 × 60
PVC
b 1 3 × 2.0 10.9 G 3 3 × 5.5 15.2 1 × 22 45.7
L 2
2 × 1.25 9.8 3×2
4 × 14 21.7 3 × 60 45.7
Three-phase Chloroprene
H 3 3 × 14 19.7 7 × 3.5 Chloroprene
Rubber M 1 21.3
No. of Cores × Outer Dia. 3 × 1.25 10.5 2×2 Rubber
Code Cables
mm2 mm Material 4 × 14 21.7 7 × 5.5
N 1 24.4
I 3 3 × 14 19.7 2×2
A 1 4 × 1.25 11.1
4 × 1.25 11.3 7×8
B 1 4 × 2.0 11.8 PVC O 1 25.6
4 × 14 21.7 Chloroprene 2×2
C 1 4 × 3.5 13.9 J 3 3 × 14 19.7 Rubber 4 × 14 21.7 Chloroprene
D 1 4 × 3.5 14.1 4 × 1.25 11.1 PVC P 3 3 × 14 19.7 Rubber
E 1 4 × 5.5 16.8 3 × 38 2 × 1.25 9.6 PVC
4 × 3.5 14.1 Chloroprene 1 × 22 35.8 Chloroprene 4 × 22 28.8 Chloroprene
Rubber K 2
F 3 3 × 3.5 12.9 3×2 Rubber Q 3 3 × 22 26.1 Rubber
2 × 1.25 9.8 3 × 38 35.9 4 × 1.25 11.1 PVC
TSURUMI OPTIONS
■ SPECIAL VERSION WITH GALVANIC CORROSION PROTECTION
In sea water, the effect of galvanic corrosion is more serious than that of ordinary corrosion. When two kinds of metals are dipped
into an electrolytic liquid, a battery phenomenon occurs due to the difference in the electric potential of the two metals. In this
case, the metal having the higher potential corrodes first. As an option, Tsurumi can supply pumps with parts made of higher
electric potential metal as the sacrificial anode.
SPECIAL ACCESSORIES
■ FLOAT SWITCHES
Tsurumi offers two types of float switches (liquid level sensors). A micro-switch is incorporated in both types.
Model MC-2 is a heavy-duty type float Model RF-5 is an economy type float which
switch with a shock absorber. Having can detect upper/lower-limit water levels with
equipped with a high grade micro switch, the single float. The snap on-off action ensures
MC-2 assures trouble-free operation in the stable operation in clean or waste water
liquid containing much suspended solids containing suspended solids or oil and fat.
and floating scum. Either of the two
contacts, normally-open or normally-close,
can be selected as required.
We reserve the right to change the specifications and designs for improvement without prior notice.
Your Dealer
Shaft Tsurumi can provide the dry pit model The auto-alternation model has three floats and can be identified by the suffix “W”.
Mechanical Seal as option for the whole range of B-series Refer to standard specifications for availability and model numbers. It is available in
The mechanical seal with two seal The high-tensile stainless steel shaft pumps. the same output range of the automatic pumps.
faces containing silicon carbide used on all pumps is designed to
(SiC) is equipped with the oil have adequate strength for the The water jacket
transmission of the full load. It is
How the Auto-alternation Model Works
chamber. The advantages of the covers whole part of
seal are two-fold, it eliminates supported by C3 type, high-quality, ●Operation is enabled by merely connecting the power supply.
the motor. It effi-
spring failure caused by corrosion, deep-groove ball bearings. ciently cools the Primary Operation Secondary Operation
abrasion or fouling which prevents motor for continu-
the seal faces from closing properly, ous operations. 5 4 5
and prevents loss of cooling to the lower Impeller Leakage Sensor 4
3 3
seal faces during run-dry conditions The impeller is semi-open or shrouded A stainless steel, electrode type leakage A 1 W 2 A 1 W 2
which causes the lower seal faces to fail. type with one or two vanes. It has a sensor is standardized for large pumps
wide channel extending from inlet to of 22kW or over (ex- 1 Float 3 operates, and pump W starts to 1 Start float 4 of pump A operates to start
Oil Lifter (Patented) exit, which allows the pump to pass the cluding some models). It
AUTOMATIC MODEL discharge water. water discharge.
solid matters from inflow to discharge senses water incursion
The Oil Lifter was developed as a
with minimal blockage. into the oil chamber The automatic model has an integral
lubricating device for the mechanical 5 5
and brings the pump to control circuit and two float switches that
seal. Utilizing the centrifugal force of the 4 4
a halt with the help of a operate at a low voltage. It operates 3 3
shaft seal, the Oil Lifter forcibly supplies
control panel. automatically in response to the change A 1 W 2 A 1 W 2
lubricating oil to the mechanical seal
and continues to supply the oil to the in water levels. As it has a Circle
upper seal faces even if lubricant falls Thermal Protector (CTP) integrated into 2 Water is discharged (water level falls). 2 Water is discharged (water level falls).
below the rated volume. This amazingly MODEL NUMBER DESIGNATION the motor to protect the motor from
simple device is not only reliably overload or overheating, it is not 5 5
lubricates and cools down, but also 100 B A 6 3.7 S H required to provide an extra motor 4
3
4
3
retains the stable shaft seal effect and Discharge bore in mm Sub code for pumping head protection circuit in A W A W
2 2
extends the inspection term. H : High head the starter panel. 1 1
Name of the series L : Low head 3 Stop float 2 of pump W operates to end 3 Stop float 1 of pump A operates to end
This model can be water discharge. At this time, alternation water discharge. At the same time, start
Operation sub code identified by the start float 3 of pump W rests for one float 3 of pump W becomes ready for
None : None automatic operation Phase suffix "A" . Refer to discharge operation. operation.
Oil Lifter
A : Automatic operation None : Three-phase the standerd speci-
Mechanical Seal ✻ Primary operation and secondary operation are repeated alternately.
W : Auto-alternation operation S : Single-phase fications for avail-
Oil ✻ Both primary and secondary operations are performed simultaneously when
ability and model
Number of poles of the motor Rated motor output in kW numbers. water has risen to an abnormal level.
1 2
B-series pumps are working in many sewage
treatment plants throughout Japan because of
their excellent reputations. As durable motor is
tough enough against frequent ON/OFF,
automatic unattended operation by central
control is available.
While in overseas, Tsurumi has a lot of sales records B-series pumps being used for a temporary
with B-series pumps, too. Several inventions adopted installation during rainy season. It is used to
by the idea seeking better handling produces ease of pump up water of branch river to the main
maintenance and repair for users comparing to other stream when the water level of main stream
manufacturers. Because of this, Tsurumi pumps have becomes higher than that of the branch river.
good reputation as the most intimate pump in the world.
3 4
Discharge Bore Discharge Bore
■Dimensions ■Dimensions
Free Standing Free Standing
+
・
+
■Performance Curves ■Performance Curves
PP PP
/
/
30 30
15 15
TOS
+
6 TOS
3 20 6 20
10 2
10
3 4 5
4 5
1 1 / /
3 10 10
2
5 5 3
2
1
1
0 0 0 0
0 0.1 0.2 0.3 0.4 0.5 0 0.1 0.2 0.3 0.4 0.5 0 1.0 2.0 2.4 0 1.0 2.0 2.4
3
Capacity (m /min) Capacity (m /min) 3 TS 3
Capacity (m /min) Capacity (m3 /min)
TS
+
/ /
■Standard Specifications 50mm
Dimensions L×H mm Dry Weight *3 kg
Standard Model Automatic Model Auto-Alternation Model Speed Solids
Discharge Motor Cable Standard Model Automatic&Auto-Alternation Model Standard Model Automatic&Auto-Alternation Model
Curve (S.S.) Starting Passage Cable
Bore Output Phase Length
No. Free Guide Rail Fitting Free Guide Rail Fitting Free Guide Rail Fitting 50Hz/60Hz Method 50Hz/60Hz Code Free Guide Rail Fitting Free Guide Rail Fitting Free Guide Rail Free Guide Rail
mm kW m
Standing Standing Standing min̶1 mm Standing TOS TS Standing TOS TS Standing Fitting Standing Fitting
TOS TS TOS TS TOS TS
35×22/
1 50 50B2.4S TOS50B2.4S TS50B2.4S ̶ ̶ ̶ ̶ ̶ ̶ 0.4 Single 3000/3600 Capacitor 35×18 5 a 340×453 556×511 333×511 ̶ ̶ ̶ 25 24 ̶ ̶
35×22/
1 50 50B2.4 TOS50B2.4 TS50B2.4 ̶ ̶ ̶ ̶ ̶ ̶ 0.4 Three 3000/3600 D.O.L. 35×18 6 A 340×420 556×477 333×477 ̶ ̶ ̶ 23 22 ̶ ̶
2 50 50B2.75S TOS50B2.75S TS50B2.75S 50BA2.75S TOS50BA2.75S TS50BA2.75S ̶ ̶ ̶ 0.75 Single 3000/3600 Capacitor 21×25 5 a(b*1) 405×523 621×566 398×566 405×580 621×623 398×623 32 30 34 32
2 50 50B2.75H TOS50B2.75H TS50B2.75H 50BA2.75H TOS50BA2.75H TS50BA2.75H 50BW2.75H TOS50BW2.75H TS50BW2.75H 0.75 Three 3000/3600 D.O.L. 21×25 6 A 405×415 621×458 398×458 433×496 623×539 400×539 24 23 25 24
3 50 50B2.75 TOS50B2.75 TS50B2.75 50BA2.75 TOS50BA2.75 TS50BA2.75 50BW2.75 TOS50BW2.75 TS50BW2.75 0.75 Three 3000/3600 D.O.L. 45×20/
51×23 6 A 405×439 621×479 398×479 433×520 623×560 400×560 25 24 26 25
■Standard Specifications 80・100mm
Dimensions L×H mm Dry Weight *3 kg
Standard Model Automatic Model Auto-Alternation Model Speed Solids
Discharge Motor Cable Standard Model Automatic&Auto-Alternation Model Standard Model Automatic&Auto-Alternation Model
Curve (S.S.) Starting Passage Cable
Bore Output Phase Length
No. Free Guide Rail Fitting Free Guide Rail Fitting Free Guide Rail Fitting 50Hz/60Hz Method 50Hz/60Hz Code Free Guide Rail Fitting Free Guide Rail Fitting Free Guide Rail Free Guide Rail
mm kW m
Standing Standing Standing min̶1 mm Standing TOS TS Standing TOS TS Standing Fitting Standing Fitting
TOS TS TOS TS TOS TS
49×41/
1 80 80B21.5 TOS80B21.5 TS80B21.5 80BA21.5 TOS80BA21.5 TS80BA21.5 80BW21.5 TOS80BW21.5 TS80BW21.5 1.5 Three 3000/3600 D.O.L. 49×35 6 A 446×536 668×586 515×586 485×630 707×680 554×680 36 34 40 38
47×53/
2 100 100B42.2 TOS100B42.2 TS100B42.2 100BA42.2 TOS100BA42.2 TS100BA42.2 100BW42.2 TOS100BW42.2 TS100BW42.2 2.2 Three 1500/1800 D.O.L. 47×46 6 A(B*2) 596×616 754×631 599×631 602×733 760×748 605×748 68 64 78 74
81×53/
3 100 100B43.7 TOS100B43.7 TS100B43.7 100BA43.7 TOS100BA43.7 TS100BA43.7 100BW43.7 TOS100BW43.7 TS100BW43.7 3.7 Three 1500/1800 D.O.L. 81×47 6 B(C*2) 602×690 760×700 605×700 602×863 760×873 605×874 84 80 94 90
■Performance Curves
PP
■Performance Curves
PP
7RWDO+HDGP
7RWDO+HDGP
7RWDO+HDGP
7RWDO+HDGP
150mm
&DSDFLW\PPLQ
&DSDFLW\PPLQ
200mm
&DSDFLW\PPLQ
&DSDFLW\PPLQ
+
L L
/ /
7 8
Discharge Bore Discharge Bore
■Performance Curves
PP
■Performance Curves
PP
45 45
40 40
8
8
35 35
5
30 30
7RWDO+HDGP
7RWDO+HDGP
250mm
300mm0 0 2 4 6 8 10 12 14 16 18 20 22 24 26
0
0 2 4 6 8 10 12 14 16 18 20 22 24 26
3
&DSDFLW\PPLQ
&DSDFLW\PPLQ Capacity (m /min) Capacity (m3/min)
4 250 250B430 TO250B430 30 Three 1500/1800 Star-Delta 76×76 10 J 1295×1512 1566×1445 645 525 4 300 300B637 TO300B637 37 Three 1000/1200 Star-Delta 140×65 10 Q 1366×1644 1685×1647 785 660
63×80/ 60×90/ J
5 250 250B437 TO250B437 37 Three 1500/1800 Star-Delta 65×76 10 Q 1295×1575 1566×1508 725 600 5 300 300B445 TO300B445 45 Three 1500/1800 Star-Delta 70×76 10 1348×1586 1667×1567 785 655
+
/ / / /
9 10
Discharge Bore Discharge Bore
■Performance Curves
PP
■Performance Curves
PP
30 30
30 30
25 25
25 25
5 5
20 20
0 0 0 0
350mm 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 400mm 0 5 10 15 20 25 30 35 40 0 5 10 15 20 25 30 35 40
Capacity (m3/min) Capacity (m3/min) Capacity (m3/min) Capacity (m3/min)
4 350
350mm
350B645 TO350B645 45
130×90/
Three 1000/1200 Star-Delta 140×78 10 J 1508×1788 1845×1811 1316 1161 4 400 400B655 TO400B655 55
145×110/
Three 1000/1200 Star-Delta 175×100 10 K 1621×1878 2141×1956 1750 1700
*1 200〜240V 130×100/ K
5 400 400B675 TO400B675 75 Three 1000/1200 Star-Delta 140×90 10 1616×1878 2136×1956 1850 1800
*2 All weights excluding cable
Weights of guide rail fitting model excluding duckfoot bend *1 200〜240V
*2 All weights excluding cable
Weights of guide rail fitting model excluding duckfoot bend
■Dimensions ■Dimensions
Free Standing Guide Rail Fitting Free Standing Guide Rail Fitting
+
+
+
/ / / /
11 12
Discharge Bore Discharge Bore
600/700/800m
・・
性-600/700/800-50/60
■Performance Curves ■Performance Curves ■Dimensions
PP PP
Free Standing
18 18
10 10
16 16
4 5
14 14
4 4 0 0
0 30 50 100 0 30 50 100
3
2 2 Capacity (m /min) Capacity (m3 /min)
0 0
500mm 0 5 10 15 20 25
Capacity (m3/min)
30 35 40 45 50 0 5 10 15 20 25 30 35
Capacity (m3/min)
40 45 50
600・700・800mm
1 500 500B1037 TO500B1037 37 Three 600/̶ Star-Delta 225×100 10 K 2073×2081 2622×2183 2050 1950 50Hz only 1 600 600B1845 TO600B1845 45 Three ̶/400 Star-Delta 280×90 10 K 2522×3100 3062×3100 5000 5200 60Hz only
2 500 500B1237 TO500B1237 37 Three ̶/600 Star-Delta 225×100 10 K 2073×2081 2622×2183 2050 1950 60Hz only 2 600 600B1255 TO600B1255 55 Three 500/̶ Star-Delta 220×100 10 K 2522×3100 3062×3100 3150 3350 50Hz only
4 500 500B675 TO500B675 75 130×120/ K 4 600 600B1085 TO600B1085 85 Three 600/̶ Star-Delta 210×85 10 K 2468×3100 3008×3100 3100 3300 50Hz only
Three 1000/1200 Star-Delta 130×100 10 2263×1987 2812×2152 2150 2050 50Hz/60Hz
5 500 500B875 TO500B875 75 Three ̶/900 Star-Delta 190×80 10 K 2150×2694 2700×2644 2550 2450 60Hz only 5 600 600B1285 TO600B1285 85 Three ̶/600 Star-Delta 210×85 10 K 2468×3100 3008×3100 3100 3300 60Hz only
* All weights excluding cable 6 700 700B1265 TO700B1265 65 Three 500/̶ Star-Delta 300×85 10 K 2840×3560 3440×3660 4000 4400 50Hz only
* Weights of guide rail fitting model excluding duckfoot bend
7 700 700B1465 TO700B1465 65 Three ̶/514 Star-Delta 300×85 10 K 2840×3560 3440×3660 4000 4400 60Hz only
8 700 700B1275 TO700B1275 75 Three 500/̶ Star-Delta 300×85 10 K 2840×3560 3440×3660 4200 4600 50Hz only
■Dimensions
9 700 700B1475 TO700B1475 75 Three ̶/514 Star-Delta 300×85 10 K 2840×3560 3440×3660 4200 4600 60Hz only
Free Standing Guide Rail Fitting
10 800 800B1290 TO800B1290 90 Three 500/̶ Star-Delta 300×90 10 L 3053×3790 3623×3790 5600 5800 50Hz only
11 800 800B1490 TO800B1490 90 Three ̶/514 Star-Delta 300×90 10 L 3053×3790 3623×3790 5600 5800 60Hz only
12 800 800B14110 TO800B14110 110 Three 428/̶ Star-Delta 310×90 10 L 3053×3790 3623×3790 5800 6000 50Hz only
+
+
13 800 800B16110 TO800B16110 110 Three ̶/450 Star-Delta 310×90 10 L 3053×3790 3623×3790 5800 6000 60Hz only
* All weights excluding cable
* Weights of guide rail fitting model excluding duckfoot bend
/ /
13 14
■ CABTYRE CABLE CODE REFERENCE Submersible Sewage Pumps
Single-phase
No. of Cores × Outer Dia. No. of Cores × Outer Dia. No. of Cores × Outer Dia.
Code Cables mm Material Code Cables mm Material Code Cables mm Material
mm2 mm2 mm2
a 1 3 × 1.25 10.1 D 1 4 × 3.5 14.1 3 × 60
PVC
b 1 3 × 2.0 10.9 E 1 4 × 5.5 16.8 1 × 22 45.7
L 2
4 × 3.5 14.1 3×2
F 3 3 × 3.5 12.9 Chloroprene 3 × 60 45.7
2 × 1.25 9.8 Rubber 7 × 3.5 Chloroprene
M 1 21.3
4 × 5.5 16.8 2×2 Rubber
7 × 5.5
G 3 3 × 5.5 15.2 N 1 24.4
2×2
2 × 1.25 9.8
7×8
4 × 14 21.7 Chloroprene O 1 25.6
Three-phase 2×2
J 3 3 × 14 19.7 Rubber
4 × 14 21.7 Chloroprene
No. of Cores × Outer Dia. 4 × 1.25 11.1 PVC
Code Cables Material P 3 3 × 14 19.7 Rubber
mm2 mm 3 × 38 2 × 1.25 9.6 PVC
A 1 4 × 1.25 11.1 1 × 22 35.8 Chloroprene 4 × 22 28.8 Chloroprene
K 2
B 1 4 × 2.0 11.8 PVC 3×2 Rubber Q 3 3 × 22 26.1 Rubber
C 1 4 × 3.5 13.9 3 × 38 35.9 4 × 1.25 11.1 PVC
TSURUMI OPTIONS
■ SPECIAL VERSION WITH GALVANIC CORROSION PROTECTION
In sea water, the effect of galvanic corrosion is more serious than that of ordinary corrosion. When two kinds of metals are dipped
into an electrolytic liquid, a battery phenomenon occurs due to the difference in the electric potential of the two metals. In this
case, the metal having the higher potential corrodes first. As an option, Tsurumi can supply pumps with parts made of higher
electric potential metal as the sacrificial anode.
SPECIAL ACCESSORIES
■ FLOAT SWITCHES
Tsurumi offers two types of float switches (liquid level sensors). A micro-switch is incorporated in both types.
Model MC-2 is a heavy-duty type float Model RF-5 is an economy type float which
switch with a shock absorber. Having can detect upper/lower-limit water levels with
equipped with a high grade micro switch, the single float. The snap on-off action ensures
MC-2 assures trouble-free operation in the stable operation in clean or waste water
liquid containing much suspended solids containing suspended solids or oil and fat.
and floating scum. Either of the two
contacts, normally-open or normally-close,
can be selected as required.
We reserve the right to change the specifications and designs for improvement without prior notice.
Your Dealer