Nothing Special   »   [go: up one dir, main page]

5 KW HF Transmitter

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

TX 3500

5 kW HF Transmitter

TX 3500
5 kW HF Transmitter
The TX 3500 is a software-based
HF transmitter rated at 5 kW PEP/average
output power for communication in the
short wave (HF) frequency band.

The transmitter comprises the exciter/


receiver unit ERX 3000 T (exciter mode
activated only), the power amplifier control
unit PAC 3500, six all-solid-state power
amplifier modules PA 3100 (each incl. an
harmonic filter), and one power combiner
with an internal balancing load. All devices
are supplied by a 3-phase nominal 400 VAC
power supply with neutral consisting of
several modules.
100 %
continuous operation

FEATURES
Frequency range 1.5 MHz to 30 MHz Software defined Easy upgrade of waveforms

Output power 5 kW PEP and average ALE Optional 2nd and/or 3rd generation ALE

Touch screen control Usable with gloves Frequency hopping ECCM capability acc. to STANAG 4444

LAN interface For remote control and voice over IP Remote control Full remote control capability

Duty cycle 100 % continuous operation Built-in test Comprehensive built-in test
TX 3500
5 kW HF Transmitter

Lore, con poreces tiatemp oreperum nos etum con comnimusdae doloris tionecusam nonsed
que et, quid modi Borit molorere nitae. Sendit ditati alicill uptium et aliquae verio ma peri dolor
TRANSMIT DATA
mi, que ad qui corepel ignihil itiates dio excessi blaboritesti is dollabo repudit fugia in con cum
et di aspe
Frequency ea si odignis
range 1.5 MHz –minvere
30 MHz rfernat volesecest.
Suppression of > 36 dB / PEP
Frequency resolution 1 Hz intermodulation
RF output power 5 kW ± 1 dB, PEP/average at 50 Ω products 3. order

Reducing of output -3 dB, -6 dB, -10 dB, -20 dB Harmonics suppression > 56 dB / PEP
power in steps of Noise suppression 80 dBc / Hz
Adjustment of In 0.1 dB steps down to -9.9 dB (inband)
maximum power Noise suppression ∆f = >50 kHz:
Channel memory 1000 >138 dBc / Hz without interselector
∆f = >500 kHz:
Frequency stability < 1 x 10-8 per day, options on request
>145 dBc / Hz without interselector
Frequency changing ≤ 10 ms
time GENERAL DATA
Modes of operation
Power supply AC power supply: 3-phase, 350 VAC –
Standard AM (A3E), SSB (J3E USB/LSB), 440 VAC, 47 Hz to 63 Hz, max 25 kVA,
Data USB/LSB/ISB, ISB (B9W), CW (A1A), neutral connected
FSK (F1B), AME (R3E, H3E, H3W)
Environmental specifications
Optional Link 11 with external L11 modem, acc. to - Operating temp. 0 °C to +55 °C
MIL-STD-188-203-1A - Humidity Max. 85 % at 25 °C
Frequency hopping: (with optional FH
- EMI/EMC Acc. to VG 95373/IEC 945 and
controller), acc. to STANAG 4444
MIL-STD-461 C/462
L22 capability (with external L22
Dimensions
equipment) acc. to STANAG 5522
Height 2100 mm (45 U)
Input for external 10 MHz, 0 dBm ±10 dB, 50 Ω,
Depth 750 mm
frequency standard BNC connector
Width 1160 mm (2 individual 19” sections)
Control interface RS 232, RS 422, RS 485 and RS 422 Bus
Weight Approx. 732 kg
1200, 2400, 4800, 9600, 19200, 38400 Baud
Noise emission < 70 dBA, temperature controlled fans
LAN interface Remote control + audio (VoIP)
Air flow Approx. 3.500 m3/h
Frontpanel socket Microphone 2 mV / 150 Ω
PTT (0V = transmit) INTERNAL OPTIONS
Serial interface for software updates/
upgrades PSI 3000 HF pre- / interselector, 1.5 MHz - 30 MHz
band pass filter, selectivity: min. 40 dB at
Comprehensive built-in test (BITE)
10 % frequency deviation, autom. tuning
Suppression of > 60 dB/PEP
within < 10 ms, < 1.5 MHz low pass filter
unwanted sideband
STR 3000 Link 11 / 22 side tone receiver
Carrier suppression J3E, ISB, Link 11: > 50 dB/PEP
H3E, H3W: 4.5 dB to 6 dB / PEP
R3E: 18 dB ± 2 dB / PEP

Hagenuk Phone: +49 4347 714-101


Marinekommunikation GmbH Telefax: +49 4347 714-110
Hamburger Chaussee 25 info@hmk.atlas-elektronik.com
24220 Flintbek | Germany www.hmk.atlas-elektronik.com
Printed in Germany Technical alternations reserved ©Hagenuk Marinekommunikation GmbH 177/09_2014